Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2024.07.03 12:21
Tabular Output Report in Format: HTML
Building: ApartmentMidRise
Environment: RUNPERIOD 1 ** Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000
Simulation Timestamp: 2024-07-03 12:21:15
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
Values gathered over 8760.00 hours| Total Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
| Total Site Energy | 1488.79 | 474.95 | 527.20 |
| Net Site Energy | 1488.79 | 474.95 | 527.20 |
| Total Source Energy | 4096.06 | 1306.72 | 1450.46 |
| Net Source Energy | 4096.06 | 1306.72 | 1450.46 |
| Site=>Source Conversion Factor | |
| Electricity | 3.167 |
| Natural Gas | 1.084 |
| District Cooling | 1.056 |
| District Heating | 3.613 |
| Steam | 1.200 |
| Gasoline | 1.050 |
| Diesel | 1.050 |
| Coal | 1.050 |
| Fuel Oil No 1 | 1.050 |
| Fuel Oil No 2 | 1.050 |
| Propane | 1.050 |
| Other Fuel 1 | 1.000 |
| Other Fuel 2 | 1.000 |
| Area [m2] | |
| Total Building Area | 3134.61 |
| Net Conditioned Building Area | 2823.98 |
| Unconditioned Building Area | 310.64 |
| Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 463.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 73.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 33.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 454.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 168.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 297.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.51 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 1191.65 | 297.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.51 |
| Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | General | 463.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | LightsWired | 67.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| LightsPlugIn | 5.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | General | 33.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | ElevatorLift | 67.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| ElevatorLightsFan | 0.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| MiscPlug | 386.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| General | 168.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Pumps | General | 0.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.51 | |
| Water Heater | 0.00 | 297.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | Unassigned | 463.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | GENERAL | 73.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | Unassigned | 33.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | GENERAL | 454.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Unassigned | 168.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | Unassigned | 0.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Unassigned | 0.00 | 297.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.51 |
| Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 37.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 223.65 | 105.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| Other | 160.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 421.98 | 105.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 33.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 201.49 | 94.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| Other | 144.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 380.16 | 94.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| Electricity [GJ] | Percent Electricity [%] | |
| Fuel-Fired Power Generation | 0.000 | 0.00 |
| High Temperature Geothermal* | 0.000 | 0.00 |
| Photovoltaic Power | 0.000 | 0.00 |
| Wind Power | 0.000 | 0.00 |
| Power Conversion | 0.000 | 0.00 |
| Net Decrease in On-Site Storage | 0.000 | 0.00 |
| Total On-Site Electric Sources | 0.000 | 0.00 |
| Electricity Coming From Utility | 1191.651 | 100.00 |
| Surplus Electricity Going To Utility | 0.000 | 0.00 |
| Net Electricity From Utility | 1191.651 | 100.00 |
| Total On-Site and Utility Electric Sources | 1191.651 | 100.00 |
| Total Electricity End Uses | 1191.651 | 100.00 |
| Heat [GJ] | Percent Heat [%] | |
| Water-Side Heat Recovery | 0.00 | 0.00 |
| Air to Air Heat Recovery for Cooling | 295.86 | 99.89 |
| Air to Air Heat Recovery for Heating | 0.31 | 0.11 |
| High-Temperature Geothermal* | 0.00 | 0.00 |
| Solar Water Thermal | 0.00 | 0.00 |
| Solar Air Thermal | 0.00 | 0.00 |
| Total On-Site Thermal Sources | 296.17 | 100.00 |
| Water [m3] | Percent Water [%] | |
| Rainwater Collection | 0.00 | 0.00 |
| Condensate Collection | 0.00 | 0.00 |
| Groundwater Well | 0.00 | 0.00 |
| Total On Site Water Sources | 0.00 | 0.00 |
| - | - | - |
| Initial Storage | 0.00 | 0.00 |
| Final Storage | 0.00 | 0.00 |
| Change in Storage | 0.00 | 0.00 |
| - | - | - |
| Water Supplied by Utility | 1875.51 | 100.00 |
| - | - | - |
| Total On Site, Change in Storage, and Utility Water Sources | 1875.51 | 100.00 |
| Total Water End Uses | 1875.51 | 100.00 |
| Degrees [deltaC] | |
| Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
| Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
| Facility [Hours] | |
| Time Setpoint Not Met During Occupied Heating | 0.00 |
| Time Setpoint Not Met During Occupied Cooling | 0.00 |
| Time Not Comfortable Based on Simple ASHRAE 55-2004 | 8760.00 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 0A
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2019
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY VNM_HOCHIMINH_TANSONHOA
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PERFORMANCEPATHPROPOSED
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |ZoneCoolingSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ZoneHeatingSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ZoneElectricSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |SpaceGainsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |PeakSpaceGainsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |SpaceGainComponentsAtCoolingPeakMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ComfortReportSimple55Monthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |OccupantComfortDataSummaryMonthly
| OCCUP_GSW | OCCUP_GNW | OCCUP_OFFICE | OCCUP_GNE | OCCUP_GN1 | OCCUP_GN2 | OCCUP_GS1 | OCCUP_GS2 | OCCUP_MSW | OCCUP_MNW | OCCUP_MSE | OCCUP_MNE | OCCUP_MN1 | OCCUP_MN2 | OCCUP_MS1 | OCCUP_MS2 | OCCUP_TSW | OCCUP_TNW | OCCUP_TSE | OCCUP_TNE | OCCUP_TN1 | OCCUP_TN2 | OCCUP_TS1 | OCCUP_TS2 | OCCUP_T CORRIDOR | OCCUP_G CORRIDOR | OCCUP_M CORRIDOR |DXReportMonthly
| SPLIT GSW HP COOLING COIL | SPLIT GNW HP COOLING COIL | SPLIT OFFICE HP COOLING COIL | SPLIT GNE HP COOLING COIL | SPLIT GN1 HP COOLING COIL | SPLIT GN2 HP COOLING COIL | SPLIT GS1 HP COOLING COIL | SPLIT GS2 HP COOLING COIL | SPLIT MSW HP COOLING COIL | SPLIT MNW HP COOLING COIL | SPLIT MSE HP COOLING COIL | SPLIT MNE HP COOLING COIL | SPLIT MN1 HP COOLING COIL | SPLIT MN2 HP COOLING COIL | SPLIT MS1 HP COOLING COIL | SPLIT MS2 HP COOLING COIL | SPLIT TSW HP COOLING COIL | SPLIT TNW HP COOLING COIL | SPLIT TSE HP COOLING COIL | SPLIT TNE HP COOLING COIL | SPLIT TN1 HP COOLING COIL | SPLIT TN2 HP COOLING COIL | SPLIT TS1 HP COOLING COIL | SPLIT TS2 HP COOLING COIL |WindowReportMonthly
| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |WindowEnergyReportMonthly
| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |WindowZoneSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |WindowEnergyZoneSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| SWHSYS1 WATER HEATER |DaylightingReportMonthly
| Environment |CoilReportMonthly
| SPLIT GSW HEATING COIL | SPLIT GNW HEATING COIL | SPLIT OFFICE HEATING COIL | SPLIT GNE HEATING COIL | SPLIT GN1 HEATING COIL | SPLIT GN2 HEATING COIL | SPLIT GS1 HEATING COIL | SPLIT GS2 HEATING COIL | SPLIT MSW HEATING COIL | SPLIT MNW HEATING COIL | SPLIT MSE HEATING COIL | SPLIT MNE HEATING COIL | SPLIT MN1 HEATING COIL | SPLIT MN2 HEATING COIL | SPLIT MS1 HEATING COIL | SPLIT MS2 HEATING COIL | SPLIT TSW HEATING COIL | SPLIT TNW HEATING COIL | SPLIT TSE HEATING COIL | SPLIT TNE HEATING COIL | SPLIT TN1 HEATING COIL | SPLIT TN2 HEATING COIL | SPLIT TS1 HEATING COIL | SPLIT TS2 HEATING COIL | SPLIT GSW_SUPPHEATCOIL | SPLIT GNW_SUPPHEATCOIL | SPLIT OFFICE_SUPPHEATCOIL | SPLIT GNE_SUPPHEATCOIL | SPLIT GN1_SUPPHEATCOIL | SPLIT GN2_SUPPHEATCOIL | SPLIT GS1_SUPPHEATCOIL | SPLIT GS2_SUPPHEATCOIL | SPLIT MSW_SUPPHEATCOIL | SPLIT MNW_SUPPHEATCOIL | SPLIT MSE_SUPPHEATCOIL | SPLIT MNE_SUPPHEATCOIL | SPLIT MN1_SUPPHEATCOIL | SPLIT MN2_SUPPHEATCOIL | SPLIT MS1_SUPPHEATCOIL | SPLIT MS2_SUPPHEATCOIL | SPLIT TSW_SUPPHEATCOIL | SPLIT TNW_SUPPHEATCOIL | SPLIT TSE_SUPPHEATCOIL | SPLIT TNE_SUPPHEATCOIL | SPLIT TN1_SUPPHEATCOIL | SPLIT TN2_SUPPHEATCOIL | SPLIT TS1_SUPPHEATCOIL | SPLIT TS2_SUPPHEATCOIL | SPLIT GSW HP COOLING COIL | SPLIT GNW HP COOLING COIL | SPLIT OFFICE HP COOLING COIL | SPLIT GNE HP COOLING COIL | SPLIT GN1 HP COOLING COIL | SPLIT GN2 HP COOLING COIL | SPLIT GS1 HP COOLING COIL | SPLIT GS2 HP COOLING COIL | SPLIT MSW HP COOLING COIL | SPLIT MNW HP COOLING COIL | SPLIT MSE HP COOLING COIL | SPLIT MNE HP COOLING COIL | SPLIT MN1 HP COOLING COIL | SPLIT MN2 HP COOLING COIL | SPLIT MS1 HP COOLING COIL | SPLIT MS2 HP COOLING COIL | SPLIT TSW HP COOLING COIL | SPLIT TNW HP COOLING COIL | SPLIT TSE HP COOLING COIL | SPLIT TNE HP COOLING COIL | SPLIT TN1 HP COOLING COIL | SPLIT TN2 HP COOLING COIL | SPLIT TS1 HP COOLING COIL | SPLIT TS2 HP COOLING COIL |PlantLoopDemandReportMonthly
| SWHSYS1 |FanReportMonthly
| SPLIT GSW SUPPLY FAN | G SW APARTMENT ERV SUP FAN | G SW APARTMENT ERV EXH FAN | SPLIT GNW SUPPLY FAN | G NW APARTMENT ERV SUP FAN | G NW APARTMENT ERV EXH FAN | SPLIT OFFICE SUPPLY FAN | SPLIT GNE SUPPLY FAN | G NE APARTMENT ERV SUP FAN | G NE APARTMENT ERV EXH FAN | SPLIT GN1 SUPPLY FAN | G N1 APARTMENT ERV SUP FAN | G N1 APARTMENT ERV EXH FAN | SPLIT GN2 SUPPLY FAN | G N2 APARTMENT ERV SUP FAN | G N2 APARTMENT ERV EXH FAN | SPLIT GS1 SUPPLY FAN | G S1 APARTMENT ERV SUP FAN | G S1 APARTMENT ERV EXH FAN | SPLIT GS2 SUPPLY FAN | G S2 APARTMENT ERV SUP FAN | G S2 APARTMENT ERV EXH FAN | SPLIT MSW SUPPLY FAN | M SW APARTMENT ERV SUP FAN | M SW APARTMENT ERV EXH FAN | SPLIT MNW SUPPLY FAN | M NW APARTMENT ERV SUP FAN | M NW APARTMENT ERV EXH FAN | SPLIT MSE SUPPLY FAN | M SE APARTMENT ERV SUP FAN | M SE APARTMENT ERV EXH FAN | SPLIT MNE SUPPLY FAN | M NE APARTMENT ERV SUP FAN | M NE APARTMENT ERV EXH FAN | SPLIT MN1 SUPPLY FAN | M N1 APARTMENT ERV SUP FAN | M N1 APARTMENT ERV EXH FAN | SPLIT MN2 SUPPLY FAN | M N2 APARTMENT ERV SUP FAN | M N2 APARTMENT ERV EXH FAN | SPLIT MS1 SUPPLY FAN | M S1 APARTMENT ERV SUP FAN | M S1 APARTMENT ERV EXH FAN | SPLIT MS2 SUPPLY FAN | M S2 APARTMENT ERV SUP FAN | M S2 APARTMENT ERV EXH FAN | SPLIT TSW SUPPLY FAN | T SW APARTMENT ERV SUP FAN | T SW APARTMENT ERV EXH FAN | SPLIT TNW SUPPLY FAN | T NW APARTMENT ERV SUP FAN | T NW APARTMENT ERV EXH FAN | SPLIT TSE SUPPLY FAN | T SE APARTMENT ERV SUP FAN | T SE APARTMENT ERV EXH FAN | SPLIT TNE SUPPLY FAN | T NE APARTMENT ERV SUP FAN | T NE APARTMENT ERV EXH FAN | SPLIT TN1 SUPPLY FAN | T N1 APARTMENT ERV SUP FAN | T N1 APARTMENT ERV EXH FAN | SPLIT TN2 SUPPLY FAN | T N2 APARTMENT ERV SUP FAN | T N2 APARTMENT ERV EXH FAN | SPLIT TS1 SUPPLY FAN | T S1 APARTMENT ERV SUP FAN | T S1 APARTMENT ERV EXH FAN | SPLIT TS2 SUPPLY FAN | T S2 APARTMENT ERV SUP FAN | T S2 APARTMENT ERV EXH FAN |PumpReportMonthly
| SWHSYS1 PUMP |CondLoopDemandReportMonthly
| SWHSYS1 |ZoneTemperatureOscillationReportMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |AirLoopSystemEnergyAndWaterUseMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |AirLoopSystemComponentLoadsMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |AirLoopSystemComponentEnergyUseMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |MechanicalVentilationLoadsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
General| Value | |
| Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2024.07.03 12:21 |
| RunPeriod | RUNPERIOD 1 |
| Weather File | Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000 |
| Latitude [deg] | 10.82 |
| Longitude [deg] | 106.67 |
| Elevation [m] | 5.00 |
| Time Zone | 7.00 |
| North Axis Angle [deg] | 0.00 |
| Rotation for Appendix G [deg] | 0.00 |
| Hours Simulated [hrs] | 8760.00 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
| Above Ground Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
| Window Opening Area [m2] | 306.92 | 112.97 | 43.82 | 112.97 | 37.16 |
| Gross Window-Wall Ratio [%] | 19.90 | 20.00 | 21.25 | 20.00 | 18.02 |
| Above Ground Window-Wall Ratio [%] | 19.90 | 20.00 | 21.25 | 20.00 | 18.02 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
| Above Ground Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
| Window Opening Area [m2] | 300.26 | 112.97 | 37.16 | 112.97 | 37.16 |
| Gross Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Above Ground Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Total | |
| Gross Roof Area [m2] | 783.65 |
| Skylight Area [m2] | 0.00 |
| Skylight-Roof Ratio [%] | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| G SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| G NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| OFFICE | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 7.4895 | 18.58 | 6.6700 |
| G NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| G N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| G S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| M SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| M NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| M SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| M NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| M N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| M S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| T SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| T NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| T SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| T NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| T N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| T S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 0.00 | 1.11 | 1.11 | 5.2871 | 18.58 | 0.0000 |
| G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 0.00 | 3.32 | 3.32 | 5.2871 | 18.58 | 515.3919 |
| M CORRIDOR | 77.66 | No | Yes | 236.69 | 2.00 | 10.22 | 0.00 | 1.11 | 1.11 | 5.2871 | 18.58 | 0.0000 |
| Total | 3134.61 | 9553.84 | 1542.04 | 0.00 | 306.92 | 306.92 | 5.5258 | 31.67 | 18.7777 | |||
| Conditioned Total | 2823.98 | 8607.06 | 1501.17 | 0.00 | 300.26 | 300.26 | 5.5521 | 34.33 | 6.6700 | |||
| Unconditioned Total | 310.64 | 946.78 | 40.87 | 0.00 | 6.66 | 6.66 | 5.2871 | 18.58 | 128.8480 | |||
| Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
| G SW APARTMENT | 88.25 | Yes | Yes | 1.00 | G SW APARTMENT | GENERAL | G SW APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| G NW APARTMENT | 88.25 | Yes | Yes | 1.00 | G NW APARTMENT | GENERAL | G NW APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| OFFICE | 88.25 | Yes | Yes | 1.00 | OFFICE | GENERAL | OFFICE | 7.4895 | 18.58 | 6.6700 | |
| G NE APARTMENT | 88.25 | Yes | Yes | 1.00 | G NE APARTMENT | GENERAL | G NE APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| G N1 APARTMENT | 88.25 | Yes | Yes | 1.00 | G N1 APARTMENT | GENERAL | G N1 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| G N2 APARTMENT | 88.25 | Yes | Yes | 1.00 | G N2 APARTMENT | GENERAL | G N2 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| G S1 APARTMENT | 88.25 | Yes | Yes | 1.00 | G S1 APARTMENT | GENERAL | G S1 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| G S2 APARTMENT | 88.25 | Yes | Yes | 1.00 | G S2 APARTMENT | GENERAL | G S2 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M SW APARTMENT | 88.25 | Yes | Yes | 2.00 | M SW APARTMENT | GENERAL | M SW APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M NW APARTMENT | 88.25 | Yes | Yes | 2.00 | M NW APARTMENT | GENERAL | M NW APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M SE APARTMENT | 88.25 | Yes | Yes | 2.00 | M SE APARTMENT | GENERAL | M SE APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M NE APARTMENT | 88.25 | Yes | Yes | 2.00 | M NE APARTMENT | GENERAL | M NE APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M N1 APARTMENT | 88.25 | Yes | Yes | 2.00 | M N1 APARTMENT | GENERAL | M N1 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M N2 APARTMENT | 88.25 | Yes | Yes | 2.00 | M N2 APARTMENT | GENERAL | M N2 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M S1 APARTMENT | 88.25 | Yes | Yes | 2.00 | M S1 APARTMENT | GENERAL | M S1 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M S2 APARTMENT | 88.25 | Yes | Yes | 2.00 | M S2 APARTMENT | GENERAL | M S2 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T SW APARTMENT | 88.25 | Yes | Yes | 1.00 | T SW APARTMENT | GENERAL | T SW APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T NW APARTMENT | 88.25 | Yes | Yes | 1.00 | T NW APARTMENT | GENERAL | T NW APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T SE APARTMENT | 88.25 | Yes | Yes | 1.00 | T SE APARTMENT | GENERAL | T SE APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T NE APARTMENT | 88.25 | Yes | Yes | 1.00 | T NE APARTMENT | GENERAL | T NE APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T N1 APARTMENT | 88.25 | Yes | Yes | 1.00 | T N1 APARTMENT | GENERAL | T N1 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T N2 APARTMENT | 88.25 | Yes | Yes | 1.00 | T N2 APARTMENT | GENERAL | T N2 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T S1 APARTMENT | 88.25 | Yes | Yes | 1.00 | T S1 APARTMENT | GENERAL | T S1 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T S2 APARTMENT | 88.25 | Yes | Yes | 1.00 | T S2 APARTMENT | GENERAL | T S2 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T CORRIDOR | 77.66 | No | Yes | 1.00 | T CORRIDOR | GENERAL | T CORRIDOR | 5.2871 | 18.58 | 0.0000 | |
| G CORRIDOR | 77.66 | No | Yes | 1.00 | G CORRIDOR | GENERAL | G CORRIDOR | 5.2871 | 18.58 | 515.3919 | |
| M CORRIDOR | 77.66 | No | Yes | 2.00 | M CORRIDOR | GENERAL | M CORRIDOR | 5.2871 | 18.58 | 0.0000 | |
| Total | 3134.61 | 5.5258 | 15.84 | 18.7777 | |||||||
| Conditioned Total | 2823.98 | 5.5521 | 17.17 | 6.6700 | |||||||
| Unconditioned Total | 310.64 | 5.2871 | 9.29 | 128.8480 | |||||||
| Not Part of Total | 0.00 | 0.0000 | 0.00 | 0.0000 |
| Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| GENERAL | 3134.61 | 2823.98 | 310.64 | 0.00 | 4.1584 | 41.91 | 17.2755 |
| Total | 3134.61 | 2823.98 | 310.64 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
End Uses| Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Time of Peak | 13-JUN-16:10 | 17-JAN-07:49 | - | - | - | - | - | - | - | - | - | - | 03-JAN-07:19 |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 27939.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 3020.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 22246.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 8152.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 14.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 18960.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 61373.15 | 18960.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | General | 27939.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | LightsWired | 2720.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| LightsPlugIn | 299.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | ElevatorLift | 3772.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| ElevatorLightsFan | 31.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| MiscPlug | 18442.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| General | 8152.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Pumps | General | 14.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Water Heater | 0.00 | 18960.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
Values gathered over 8760.00 hours| Source Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 1466.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 231.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 104.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 1437.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 532.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 1.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 322.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 3773.96 | 322.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 519.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 81.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 37.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 509.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 188.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 114.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 1336.40 | 114.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 467.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 73.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 33.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 458.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 169.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 102.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 1203.96 | 102.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
ZoneHVAC:EnergyRecoveryVentilator| User-Specified Supply Air Flow Rate [m3/s] | User-Specified Exhaust Air Flow Rate [m3/s] | |
| G SW APARTMENT ERV | 0.025955 | 0.025955 |
| G NW APARTMENT ERV | 0.025955 | 0.025955 |
| G NE APARTMENT ERV | 0.025955 | 0.025955 |
| G N1 APARTMENT ERV | 0.025955 | 0.025955 |
| G N2 APARTMENT ERV | 0.025955 | 0.025955 |
| G S1 APARTMENT ERV | 0.025955 | 0.025955 |
| G S2 APARTMENT ERV | 0.025955 | 0.025955 |
| M SW APARTMENT ERV | 0.051909 | 0.051909 |
| M NW APARTMENT ERV | 0.051909 | 0.051909 |
| M SE APARTMENT ERV | 0.051909 | 0.051909 |
| M NE APARTMENT ERV | 0.051909 | 0.051909 |
| M N1 APARTMENT ERV | 0.051909 | 0.051909 |
| M N2 APARTMENT ERV | 0.051909 | 0.051909 |
| M S1 APARTMENT ERV | 0.051909 | 0.051909 |
| M S2 APARTMENT ERV | 0.051909 | 0.051909 |
| T SW APARTMENT ERV | 0.025955 | 0.025955 |
| T NW APARTMENT ERV | 0.025955 | 0.025955 |
| T SE APARTMENT ERV | 0.025955 | 0.025955 |
| T NE APARTMENT ERV | 0.025955 | 0.025955 |
| T N1 APARTMENT ERV | 0.025955 | 0.025955 |
| T N2 APARTMENT ERV | 0.025955 | 0.025955 |
| T S1 APARTMENT ERV | 0.025955 | 0.025955 |
| T S2 APARTMENT ERV | 0.025955 | 0.025955 |
| Design Size Maximum Flow Rate [m3/s] | |
| G SW APARTMENT ERV SUP FAN | 0.025955 |
| G SW APARTMENT ERV EXH FAN | 0.025955 |
| G NW APARTMENT ERV SUP FAN | 0.025955 |
| G NW APARTMENT ERV EXH FAN | 0.025955 |
| G NE APARTMENT ERV SUP FAN | 0.025955 |
| G NE APARTMENT ERV EXH FAN | 0.025955 |
| G N1 APARTMENT ERV SUP FAN | 0.025955 |
| G N1 APARTMENT ERV EXH FAN | 0.025955 |
| G N2 APARTMENT ERV SUP FAN | 0.025955 |
| G N2 APARTMENT ERV EXH FAN | 0.025955 |
| G S1 APARTMENT ERV SUP FAN | 0.025955 |
| G S1 APARTMENT ERV EXH FAN | 0.025955 |
| G S2 APARTMENT ERV SUP FAN | 0.025955 |
| G S2 APARTMENT ERV EXH FAN | 0.025955 |
| M SW APARTMENT ERV SUP FAN | 0.051909 |
| M SW APARTMENT ERV EXH FAN | 0.051909 |
| M NW APARTMENT ERV SUP FAN | 0.051909 |
| M NW APARTMENT ERV EXH FAN | 0.051909 |
| M SE APARTMENT ERV SUP FAN | 0.051909 |
| M SE APARTMENT ERV EXH FAN | 0.051909 |
| M NE APARTMENT ERV SUP FAN | 0.051909 |
| M NE APARTMENT ERV EXH FAN | 0.051909 |
| M N1 APARTMENT ERV SUP FAN | 0.051909 |
| M N1 APARTMENT ERV EXH FAN | 0.051909 |
| M N2 APARTMENT ERV SUP FAN | 0.051909 |
| M N2 APARTMENT ERV EXH FAN | 0.051909 |
| M S1 APARTMENT ERV SUP FAN | 0.051909 |
| M S1 APARTMENT ERV EXH FAN | 0.051909 |
| M S2 APARTMENT ERV SUP FAN | 0.051909 |
| M S2 APARTMENT ERV EXH FAN | 0.051909 |
| T SW APARTMENT ERV SUP FAN | 0.025955 |
| T SW APARTMENT ERV EXH FAN | 0.025955 |
| T NW APARTMENT ERV SUP FAN | 0.025955 |
| T NW APARTMENT ERV EXH FAN | 0.025955 |
| T SE APARTMENT ERV SUP FAN | 0.025955 |
| T SE APARTMENT ERV EXH FAN | 0.025955 |
| T NE APARTMENT ERV SUP FAN | 0.025955 |
| T NE APARTMENT ERV EXH FAN | 0.025955 |
| T N1 APARTMENT ERV SUP FAN | 0.025955 |
| T N1 APARTMENT ERV EXH FAN | 0.025955 |
| T N2 APARTMENT ERV SUP FAN | 0.025955 |
| T N2 APARTMENT ERV EXH FAN | 0.025955 |
| T S1 APARTMENT ERV SUP FAN | 0.025955 |
| T S1 APARTMENT ERV EXH FAN | 0.025955 |
| T S2 APARTMENT ERV SUP FAN | 0.025955 |
| T S2 APARTMENT ERV EXH FAN | 0.025955 |
| SPLIT GSW SUPPLY FAN | 0.312800 |
| SPLIT GNW SUPPLY FAN | 0.316136 |
| SPLIT OFFICE SUPPLY FAN | 0.372271 |
| SPLIT GNE SUPPLY FAN | 0.296849 |
| SPLIT GN1 SUPPLY FAN | 0.263793 |
| SPLIT GN2 SUPPLY FAN | 0.263411 |
| SPLIT GS1 SUPPLY FAN | 0.260650 |
| SPLIT GS2 SUPPLY FAN | 0.263359 |
| SPLIT MSW SUPPLY FAN | 0.690522 |
| SPLIT MNW SUPPLY FAN | 0.697672 |
| SPLIT MSE SUPPLY FAN | 0.642660 |
| SPLIT MNE SUPPLY FAN | 0.649822 |
| SPLIT MN1 SUPPLY FAN | 0.578177 |
| SPLIT MN2 SUPPLY FAN | 0.577289 |
| SPLIT MS1 SUPPLY FAN | 0.571054 |
| SPLIT MS2 SUPPLY FAN | 0.570162 |
| SPLIT TSW SUPPLY FAN | 0.371611 |
| SPLIT TNW SUPPLY FAN | 0.377314 |
| SPLIT TSE SUPPLY FAN | 0.337899 |
| SPLIT TNE SUPPLY FAN | 0.343589 |
| SPLIT TN1 SUPPLY FAN | 0.318645 |
| SPLIT TN2 SUPPLY FAN | 0.317424 |
| SPLIT TS1 SUPPLY FAN | 0.312907 |
| SPLIT TS2 SUPPLY FAN | 0.311683 |
| Design Size Nominal Supply Air Flow Rate [m3/s] | |
| G SW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G NW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G NE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G N1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G N2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G S1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G S2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| M SW APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M NW APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M SE APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M NE APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M N1 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M N2 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M S1 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M S2 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| T SW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T NW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T SE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T NE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T N1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T N2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T S1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T S2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| Design Size Maximum Air Flow Rate [m3/s] | |
| G SW APARTMENT DIRECT AIR | 0.312800 |
| G NW APARTMENT DIRECT AIR | 0.316136 |
| OFFICE DIRECT AIR | 0.372271 |
| G NE APARTMENT DIRECT AIR | 0.296849 |
| G N1 APARTMENT DIRECT AIR | 0.263793 |
| G N2 APARTMENT DIRECT AIR | 0.263411 |
| G S1 APARTMENT DIRECT AIR | 0.260650 |
| G S2 APARTMENT DIRECT AIR | 0.263359 |
| M SW APARTMENT DIRECT AIR | 0.690522 |
| M NW APARTMENT DIRECT AIR | 0.697672 |
| M SE APARTMENT DIRECT AIR | 0.642660 |
| M NE APARTMENT DIRECT AIR | 0.649822 |
| M N1 APARTMENT DIRECT AIR | 0.578177 |
| M N2 APARTMENT DIRECT AIR | 0.577289 |
| M S1 APARTMENT DIRECT AIR | 0.571054 |
| M S2 APARTMENT DIRECT AIR | 0.570162 |
| T SW APARTMENT DIRECT AIR | 0.371611 |
| T NW APARTMENT DIRECT AIR | 0.377314 |
| T SE APARTMENT DIRECT AIR | 0.337899 |
| T NE APARTMENT DIRECT AIR | 0.343589 |
| T N1 APARTMENT DIRECT AIR | 0.318645 |
| T N2 APARTMENT DIRECT AIR | 0.317424 |
| T S1 APARTMENT DIRECT AIR | 0.312907 |
| T S2 APARTMENT DIRECT AIR | 0.311683 |
| Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
| SPLIT GSW | 0.312800 | 0.312800 | 0.312800 | 0.312800 | 0.312800 | 0.312800 | 1.00 | 1.00 | 0.312800 |
| SPLIT GNW | 0.316136 | 0.316136 | 0.316136 | 0.316136 | 0.316136 | 0.316136 | 1.00 | 1.00 | 0.316136 |
| SPLIT OFFICE | 0.372271 | 0.372271 | 0.372271 | 0.372271 | 0.372271 | 0.372271 | 1.00 | 1.00 | 0.372271 |
| SPLIT GNE | 0.296849 | 0.296849 | 0.296849 | 0.296849 | 0.296849 | 0.296849 | 1.00 | 1.00 | 0.296849 |
| SPLIT GN1 | 0.263793 | 0.263793 | 0.263793 | 0.263793 | 0.263793 | 0.263793 | 1.00 | 1.00 | 0.263793 |
| SPLIT GN2 | 0.263411 | 0.263411 | 0.263411 | 0.263411 | 0.263411 | 0.263411 | 1.00 | 1.00 | 0.263411 |
| SPLIT GS1 | 0.260650 | 0.260650 | 0.260650 | 0.260650 | 0.260650 | 0.260650 | 1.00 | 1.00 | 0.260650 |
| SPLIT GS2 | 0.263359 | 0.263359 | 0.263359 | 0.263359 | 0.263359 | 0.263359 | 1.00 | 1.00 | 0.263359 |
| SPLIT MSW | 0.690522 | 0.690522 | 0.690522 | 0.690522 | 0.690522 | 0.690522 | 1.00 | 1.00 | 0.690522 |
| SPLIT MNW | 0.697672 | 0.697672 | 0.697672 | 0.697672 | 0.697672 | 0.697672 | 1.00 | 1.00 | 0.697672 |
| SPLIT MSE | 0.642660 | 0.642660 | 0.642660 | 0.642660 | 0.642660 | 0.642660 | 1.00 | 1.00 | 0.642660 |
| SPLIT MNE | 0.649822 | 0.649822 | 0.649822 | 0.649822 | 0.649822 | 0.649822 | 1.00 | 1.000000 | 0.649822 |
| SPLIT MN1 | 0.578177 | 0.578177 | 0.578177 | 0.578177 | 0.578177 | 0.578177 | 1.00 | 1.00 | 0.578177 |
| SPLIT MN2 | 0.577289 | 0.577289 | 0.577289 | 0.577289 | 0.577289 | 0.577289 | 1.00 | 1.00 | 0.577289 |
| SPLIT MS1 | 0.571054 | 0.571054 | 0.571054 | 0.571054 | 0.571054 | 0.571054 | 1.00 | 1.00 | 0.571054 |
| SPLIT MS2 | 0.570162 | 0.570162 | 0.570162 | 0.570162 | 0.570162 | 0.570162 | 1.00 | 1.00 | 0.570162 |
| SPLIT TSW | 0.371611 | 0.371611 | 0.371611 | 0.371611 | 0.371611 | 0.371611 | 1.00 | 1.00 | 0.371611 |
| SPLIT TNW | 0.377314 | 0.377314 | 0.377314 | 0.377314 | 0.377314 | 0.377314 | 1.00 | 1.00 | 0.377314 |
| SPLIT TSE | 0.337899 | 0.337899 | 0.337899 | 0.337899 | 0.337899 | 0.337899 | 1.00 | 1.000000 | 0.337899 |
| SPLIT TNE | 0.343589 | 0.343589 | 0.343589 | 0.343589 | 0.343589 | 0.343589 | 1.00 | 1.000000 | 0.343589 |
| SPLIT TN1 | 0.318645 | 0.318645 | 0.318645 | 0.318645 | 0.318645 | 0.318645 | 1.00 | 1.00 | 0.318645 |
| SPLIT TN2 | 0.317424 | 0.317424 | 0.317424 | 0.317424 | 0.317424 | 0.317424 | 1.00 | 1.00 | 0.317424 |
| SPLIT TS1 | 0.312907 | 0.312907 | 0.312907 | 0.312907 | 0.312907 | 0.312907 | 1.00 | 1.00 | 0.312907 |
| SPLIT TS2 | 0.311683 | 0.311683 | 0.311683 | 0.311683 | 0.311683 | 0.311683 | 1.00 | 1.00 | 0.311683 |
| Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
| SPLIT GSW_OA_CONTROLLER | 0.312800 | 0.025955 |
| SPLIT GNW_OA_CONTROLLER | 0.316136 | 0.025955 |
| SPLIT OFFICE_OA_CONTROLLER | 0.372271 | 0.038106 |
| SPLIT GNE_OA_CONTROLLER | 0.296849 | 0.025955 |
| SPLIT GN1_OA_CONTROLLER | 0.263793 | 0.025955 |
| SPLIT GN2_OA_CONTROLLER | 0.263411 | 0.025955 |
| SPLIT GS1_OA_CONTROLLER | 0.260650 | 0.025955 |
| SPLIT GS2_OA_CONTROLLER | 0.263359 | 0.025955 |
| SPLIT MSW_OA_CONTROLLER | 0.690522 | 0.051909 |
| SPLIT MNW_OA_CONTROLLER | 0.697672 | 0.051909 |
| SPLIT MSE_OA_CONTROLLER | 0.642660 | 0.051909 |
| SPLIT MNE_OA_CONTROLLER | 0.649822 | 0.051909 |
| SPLIT MN1_OA_CONTROLLER | 0.578177 | 0.051909 |
| SPLIT MN2_OA_CONTROLLER | 0.577289 | 0.051909 |
| SPLIT MS1_OA_CONTROLLER | 0.571054 | 0.051909 |
| SPLIT MS2_OA_CONTROLLER | 0.570162 | 0.051909 |
| SPLIT TSW_OA_CONTROLLER | 0.371611 | 0.025955 |
| SPLIT TNW_OA_CONTROLLER | 0.377314 | 0.025955 |
| SPLIT TSE_OA_CONTROLLER | 0.337899 | 0.025955 |
| SPLIT TNE_OA_CONTROLLER | 0.343589 | 0.025955 |
| SPLIT TN1_OA_CONTROLLER | 0.318645 | 0.025955 |
| SPLIT TN2_OA_CONTROLLER | 0.317424 | 0.025955 |
| SPLIT TS1_OA_CONTROLLER | 0.312907 | 0.025955 |
| SPLIT TS2_OA_CONTROLLER | 0.311683 | 0.025955 |
| Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | Design Size Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | User-Specified Supplemental Heating Coil Nominal Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
| SPLIT GSW_UNITARY_PACKAGE_DX | 0.312800 | 0.312800 | 0.312800 | 0.312800 | 5881.00 | 3940.27 | 40.00 | 5881.00 | 1.00 |
| SPLIT GNW_UNITARY_PACKAGE_DX | 0.316136 | 0.316136 | 0.316136 | 0.316136 | 5900.19 | 3953.13 | 40.00 | 5900.19 | 1.00 |
| SPLIT OFFICE_UNITARY_PACKAGE_DX | 0.372271 | 0.372271 | 0.372271 | 0.372271 | 6944.57 | 4652.86 | 40.00 | 6944.57 | 1.00 |
| SPLIT GNE_UNITARY_PACKAGE_DX | 0.296849 | 0.296849 | 0.296849 | 0.296849 | 5611.16 | 3759.47 | 40.00 | 5611.16 | 1.00 |
| SPLIT GN1_UNITARY_PACKAGE_DX | 0.263793 | 0.263793 | 0.263793 | 0.263793 | 5069.03 | 3396.25 | 40.00 | 5069.03 | 1.00 |
| SPLIT GN2_UNITARY_PACKAGE_DX | 0.263411 | 0.263411 | 0.263411 | 0.263411 | 5063.22 | 3392.36 | 40.00 | 5063.22 | 1.00 |
| SPLIT GS1_UNITARY_PACKAGE_DX | 0.260650 | 0.260650 | 0.260650 | 0.260650 | 5082.78 | 3405.46 | 40.00 | 5082.78 | 1.00 |
| SPLIT GS2_UNITARY_PACKAGE_DX | 0.263359 | 0.263359 | 0.263359 | 0.263359 | 5124.92 | 3433.70 | 40.00 | 5124.92 | 1.00 |
| SPLIT MSW_UNITARY_PACKAGE_DX | 0.690522 | 0.690522 | 0.690522 | 0.690522 | 12843.65 | 8605.25 | 40.00 | 12843.65 | 1.00 |
| SPLIT MNW_UNITARY_PACKAGE_DX | 0.697672 | 0.697672 | 0.697672 | 0.697672 | 12898.91 | 8642.27 | 40.00 | 12898.91 | 1.00 |
| SPLIT MSE_UNITARY_PACKAGE_DX | 0.642660 | 0.642660 | 0.642660 | 0.642660 | 12146.23 | 8137.98 | 40.00 | 12146.23 | 1.00 |
| SPLIT MNE_UNITARY_PACKAGE_DX | 0.649822 | 0.649822 | 0.649822 | 0.649822 | 12183.91 | 8163.22 | 40.00 | 12183.91 | 1.00 |
| SPLIT MN1_UNITARY_PACKAGE_DX | 0.578177 | 0.578177 | 0.578177 | 0.578177 | 10992.24 | 7364.80 | 40.00 | 10992.24 | 1.00 |
| SPLIT MN2_UNITARY_PACKAGE_DX | 0.577289 | 0.577289 | 0.577289 | 0.577289 | 10978.77 | 7355.77 | 40.00 | 10978.77 | 1.00 |
| SPLIT MS1_UNITARY_PACKAGE_DX | 0.571054 | 0.571054 | 0.571054 | 0.571054 | 11000.75 | 7370.50 | 40.00 | 11000.75 | 1.00 |
| SPLIT MS2_UNITARY_PACKAGE_DX | 0.570162 | 0.570162 | 0.570162 | 0.570162 | 10987.57 | 7361.67 | 40.00 | 10987.57 | 1.00 |
| SPLIT TSW_UNITARY_PACKAGE_DX | 0.371611 | 0.371611 | 0.371611 | 0.371611 | 6855.57 | 4593.23 | 40.00 | 6855.57 | 1.00 |
| SPLIT TNW_UNITARY_PACKAGE_DX | 0.377314 | 0.377314 | 0.377314 | 0.377314 | 6925.23 | 4639.90 | 40.00 | 6925.23 | 1.00 |
| SPLIT TSE_UNITARY_PACKAGE_DX | 0.337899 | 0.337899 | 0.337899 | 0.337899 | 6343.61 | 4250.22 | 40.00 | 6343.61 | 1.00 |
| SPLIT TNE_UNITARY_PACKAGE_DX | 0.343589 | 0.343589 | 0.343589 | 0.343589 | 6408.42 | 4293.64 | 40.00 | 6408.42 | 1.00 |
| SPLIT TN1_UNITARY_PACKAGE_DX | 0.318645 | 0.318645 | 0.318645 | 0.318645 | 5953.58 | 3988.90 | 40.00 | 5953.58 | 1.00 |
| SPLIT TN2_UNITARY_PACKAGE_DX | 0.317424 | 0.317424 | 0.317424 | 0.317424 | 5934.90 | 3976.38 | 40.00 | 5934.90 | 1.00 |
| SPLIT TS1_UNITARY_PACKAGE_DX | 0.312907 | 0.312907 | 0.312907 | 0.312907 | 5893.41 | 3948.58 | 40.00 | 5893.41 | 1.00 |
| SPLIT TS2_UNITARY_PACKAGE_DX | 0.311683 | 0.311683 | 0.311683 | 0.311683 | 5874.94 | 3936.21 | 40.00 | 5874.94 | 1.00 |
| Design Size Rated Air Flow Rate [m3/s] | Design Size Gross Rated Total Cooling Capacity [W] | Design Size Gross Rated Sensible Heat Ratio | |
| SPLIT GSW HP COOLING COIL | 0.312800 | 5881.00 | 0.800704 |
| SPLIT GNW HP COOLING COIL | 0.316136 | 5900.19 | 0.800092 |
| SPLIT OFFICE HP COOLING COIL | 0.372271 | 6944.57 | 0.800246 |
| SPLIT GNE HP COOLING COIL | 0.296849 | 5611.16 | 0.798970 |
| SPLIT GN1 HP COOLING COIL | 0.263793 | 5069.03 | 0.792717 |
| SPLIT GN2 HP COOLING COIL | 0.263411 | 5063.22 | 0.792620 |
| SPLIT GS1 HP COOLING COIL | 0.260650 | 5082.78 | 0.786096 |
| SPLIT GS2 HP COOLING COIL | 0.263359 | 5124.92 | 0.786747 |
| SPLIT MSW HP COOLING COIL | 0.690522 | 12843.65 | 0.800206 |
| SPLIT MNW HP COOLING COIL | 0.697672 | 12898.91 | 0.800178 |
| SPLIT MSE HP COOLING COIL | 0.642660 | 12146.23 | 0.800012 |
| SPLIT MNE HP COOLING COIL | 0.649822 | 12183.91 | 0.800593 |
| SPLIT MN1 HP COOLING COIL | 0.578177 | 10992.24 | 0.797115 |
| SPLIT MN2 HP COOLING COIL | 0.577289 | 10978.77 | 0.797016 |
| SPLIT MS1 HP COOLING COIL | 0.571054 | 11000.75 | 0.790927 |
| SPLIT MS2 HP COOLING COIL | 0.570162 | 10987.57 | 0.790812 |
| SPLIT TSW HP COOLING COIL | 0.371611 | 6855.57 | 0.800896 |
| SPLIT TNW HP COOLING COIL | 0.377314 | 6925.23 | 0.800589 |
| SPLIT TSE HP COOLING COIL | 0.337899 | 6343.61 | 0.800178 |
| SPLIT TNE HP COOLING COIL | 0.343589 | 6408.42 | 0.800302 |
| SPLIT TN1 HP COOLING COIL | 0.318645 | 5953.58 | 0.800732 |
| SPLIT TN2 HP COOLING COIL | 0.317424 | 5934.90 | 0.800506 |
| SPLIT TS1 HP COOLING COIL | 0.312907 | 5893.41 | 0.800132 |
| SPLIT TS2 HP COOLING COIL | 0.311683 | 5874.94 | 0.800881 |
| Design Size Rated Air Flow Rate [m3/s] | Design Size Gross Rated Heating Capacity [W] | |
| SPLIT GSW HEATING COIL | 0.312800 | 5881.00 |
| SPLIT GNW HEATING COIL | 0.316136 | 5900.19 |
| SPLIT OFFICE HEATING COIL | 0.372271 | 6944.57 |
| SPLIT GNE HEATING COIL | 0.296849 | 5611.16 |
| SPLIT GN1 HEATING COIL | 0.263793 | 5069.03 |
| SPLIT GN2 HEATING COIL | 0.263411 | 5063.22 |
| SPLIT GS1 HEATING COIL | 0.260650 | 5082.78 |
| SPLIT GS2 HEATING COIL | 0.263359 | 5124.92 |
| SPLIT MSW HEATING COIL | 0.690522 | 12843.65 |
| SPLIT MNW HEATING COIL | 0.697672 | 12898.91 |
| SPLIT MSE HEATING COIL | 0.642660 | 12146.23 |
| SPLIT MNE HEATING COIL | 0.649822 | 12183.91 |
| SPLIT MN1 HEATING COIL | 0.578177 | 10992.24 |
| SPLIT MN2 HEATING COIL | 0.577289 | 10978.77 |
| SPLIT MS1 HEATING COIL | 0.571054 | 11000.75 |
| SPLIT MS2 HEATING COIL | 0.570162 | 10987.57 |
| SPLIT TSW HEATING COIL | 0.371611 | 6855.57 |
| SPLIT TNW HEATING COIL | 0.377314 | 6925.23 |
| SPLIT TSE HEATING COIL | 0.337899 | 6343.61 |
| SPLIT TNE HEATING COIL | 0.343589 | 6408.42 |
| SPLIT TN1 HEATING COIL | 0.318645 | 5953.58 |
| SPLIT TN2 HEATING COIL | 0.317424 | 5934.90 |
| SPLIT TS1 HEATING COIL | 0.312907 | 5893.41 |
| SPLIT TS2 HEATING COIL | 0.311683 | 5874.94 |
| Design Size Nominal Capacity [W] | |
| SPLIT GSW_SUPPHEATCOIL | 5881.00 |
| SPLIT GNW_SUPPHEATCOIL | 5900.19 |
| SPLIT OFFICE_SUPPHEATCOIL | 6944.57 |
| SPLIT GNE_SUPPHEATCOIL | 5611.16 |
| SPLIT GN1_SUPPHEATCOIL | 5069.03 |
| SPLIT GN2_SUPPHEATCOIL | 5063.22 |
| SPLIT GS1_SUPPHEATCOIL | 5082.78 |
| SPLIT GS2_SUPPHEATCOIL | 5124.92 |
| SPLIT MSW_SUPPHEATCOIL | 12843.65 |
| SPLIT MNW_SUPPHEATCOIL | 12898.91 |
| SPLIT MSE_SUPPHEATCOIL | 12146.23 |
| SPLIT MNE_SUPPHEATCOIL | 12183.91 |
| SPLIT MN1_SUPPHEATCOIL | 10992.24 |
| SPLIT MN2_SUPPHEATCOIL | 10978.77 |
| SPLIT MS1_SUPPHEATCOIL | 11000.75 |
| SPLIT MS2_SUPPHEATCOIL | 10987.57 |
| SPLIT TSW_SUPPHEATCOIL | 6855.57 |
| SPLIT TNW_SUPPHEATCOIL | 6925.23 |
| SPLIT TSE_SUPPHEATCOIL | 6343.61 |
| SPLIT TNE_SUPPHEATCOIL | 6408.42 |
| SPLIT TN1_SUPPHEATCOIL | 5953.58 |
| SPLIT TN2_SUPPHEATCOIL | 5934.90 |
| SPLIT TS1_SUPPHEATCOIL | 5893.41 |
| SPLIT TS2_SUPPHEATCOIL | 5874.94 |
| Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
| SWHSYS1 | 0.000113 | 0.013615 |
| Design Flow Rate [m3/s] | Design Power Consumption [W] | |
| SWHSYS1 PUMP | 0.000113 | 14.49 |
| Use Side Design Flow Rate [m3/s] | |
| SWHSYS1 WATER HEATER | 0.000113 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces| None |
| Possible Shadow Receivers | |
| G SWALL SWA | GWINDOW1 S SWA | |
| G WWALL SWA | GWINDOW1 W SWA | |
| G NWALL NWA | GWINDOW1 N NWA | |
| G WWALL NWA | GWINDOW1 W NWA | |
| G SWALL SEA | GWINDOW1 S SEA | |
| G EWALL SEA | GWINDOW1 E SEA | |
| G NWALL NEA | GWINDOW1 N NEA | |
| G EWALL NEA | GWINDOW1 E NEA | |
| G NWALL N1A | GWINDOW1 N N1A | |
| G NWALL N2A | GWINDOW1 N N2A | |
| G SWALL S1A | GWINDOW1 S S1A | |
| G SWALL S2A | GWINDOW1 S S2A | |
| M WWALL SWA | MWINDOW1 W SWA | |
| M SWALL SWA | MWINDOW1 S SWA | |
| M NWALL NWA | MWINDOW1 N NWA | |
| M WWALL NWA | MWINDOW1 W NWA | |
| M EWALL SEA | MWINDOW1 E SEA | |
| M SWALL SEA | MWINDOW1 S SEA | |
| M NWALL NEA | MWINDOW1 N NEA | |
| M EWALL NEA | MWINDOW1 E NEA | |
| M NWALL N1A | MWINDOW1 N N1A | |
| M NWALL N2A | MWINDOW1 N N2A | |
| M SWALL S1A | MWINDOW1 S S1A | |
| M SWALL S2A | MWINDOW1 S S2A | |
| T WWALL SWA | TWINDOW1 W SWA | |
| T SWALL SWA | TWINDOW1 S SWA | |
| T NWALL NWA | TWINDOW1 N NWA | |
| T WWALL NWA | TWINDOW1 W NWA | |
| T EWALL SEA | TWINDOW1 E SEA | |
| T SWALL SEA | TWINDOW1 S SEA | |
| T NWALL NEA | TWINDOW1 N NEA | |
| T EWALL NEA | TWINDOW1 E NEA | |
| T NWALL N1A | TWINDOW1 N N1A | |
| T NWALL N2A | TWINDOW1 N N2A | |
| T SWALL S1A | TWINDOW1 S S1A | |
| T SWALL S2A | TWINDOW1 S S2A | |
| T EWALL C | TWINDOW14 | |
| G EWALL C | ENTRANCE DOOR | |
| M EWALL C | MWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
Time Not Meeting the Adaptive Comfort Models during Occupied Hours| ASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
Version| Version ID | |
| 1 | 22.1 |
| #TimeSteps | Minutes per TimeStep {minutes} | |
| 1 | 6 | 10 |
| Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
| 1 | 1 | 20 | 2 | 8 |
| Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
| 1 | Yes | Yes | No | No | Yes | No |
| Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
| 1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
| Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
| 1 | 0.556 | 0.556 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 26.90 | 26.70 | 26.00 | 26.40 | 27.50 | 28.30 | 29.20 | 29.00 | 28.90 | 27.20 | 27.50 | 27.60 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Normal | Daylighting {dimensionless} | |
| 1 | 1.000 | 1.000 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
| 1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
| Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
| 1 | Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000 | 10.82 | 106.67 | 7.00 | 5.00 | 101265 | 1.2036 |
| Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
| 1 | Correlation | NA | 27.60 | 3.20 | NA |
| Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
| 1 | ApartmentMidRise | 0.000 | City | 4.00000E-002 | 0.40000 | FullExterior | 25 | 6 |
| Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Value {Anisotropic} | |
| 1 | Anisotropic |
| Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
| 1 | ThirdOrderBackwardDifference |
| Simulation {Yes/No} | Carbon Dioxide Concentration | |
| 1 | No | N/A |
| Simulation {Yes/No} | Generic Contaminant Concentration | |
| 1 | No | N/A |
| Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
| 1 | No | N/A | N/A | N/A |
| Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
| 1 | RegulaFalsi |
| Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
| 1 | 0.330 | 460.000 | 6.500000E-003 |
| Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
| 1 | LowerLeftCorner | Clockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
| Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
| 1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
| Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
| 1 | 0 | 0 | 0 |
| Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
| 1 | 27 | 243 | 39 |
| Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
| 1 | G SW APARTMENT | 0.0 | 0.00 | 0.00 | 0.00 | 5.79 | 3.81 | 1.52 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 2 | G NW APARTMENT | 0.0 | 0.00 | 9.30 | 0.00 | 5.79 | 13.11 | 1.52 | 1 | 1 | 1 | 0.00 | 11.58 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 3 | OFFICE | 0.0 | 34.75 | 0.00 | 0.00 | 40.54 | 3.81 | 1.52 | 1 | 1 | 1 | 34.75 | 46.33 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 4 | G NE APARTMENT | 0.0 | 34.75 | 9.30 | 0.00 | 40.54 | 13.11 | 1.52 | 1 | 1 | 1 | 34.75 | 46.33 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 5 | G N1 APARTMENT | 0.0 | 11.58 | 9.30 | 0.00 | 17.37 | 13.11 | 1.52 | 1 | 1 | 1 | 11.58 | 23.16 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 6 | G N2 APARTMENT | 0.0 | 23.16 | 9.30 | 0.00 | 28.95 | 13.11 | 1.52 | 1 | 1 | 1 | 23.16 | 34.75 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 7 | G S1 APARTMENT | 0.0 | 11.58 | 0.00 | 0.00 | 17.37 | 3.81 | 1.52 | 1 | 1 | 1 | 11.58 | 23.16 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 8 | G S2 APARTMENT | 0.0 | 23.16 | 0.00 | 0.00 | 28.95 | 3.81 | 1.52 | 1 | 1 | 1 | 23.16 | 34.75 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 9 | M SW APARTMENT | 0.0 | 0.00 | 0.00 | 3.05 | 5.79 | 3.81 | 4.57 | 1 | 1 | 2 | 0.00 | 11.58 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 10 | M NW APARTMENT | 0.0 | 0.00 | 9.30 | 3.05 | 5.79 | 13.11 | 4.57 | 1 | 1 | 2 | 0.00 | 11.58 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 11 | M SE APARTMENT | 0.0 | 34.75 | 0.00 | 3.05 | 40.54 | 3.81 | 4.57 | 1 | 1 | 2 | 34.75 | 46.33 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 12 | M NE APARTMENT | 0.0 | 34.75 | 9.30 | 3.05 | 40.54 | 13.11 | 4.57 | 1 | 1 | 2 | 34.75 | 46.33 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 13 | M N1 APARTMENT | 0.0 | 11.58 | 9.30 | 3.05 | 17.37 | 13.11 | 4.57 | 1 | 1 | 2 | 11.58 | 23.16 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 14 | M N2 APARTMENT | 0.0 | 23.16 | 9.30 | 3.05 | 28.95 | 13.11 | 4.57 | 1 | 1 | 2 | 23.16 | 34.75 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 15 | M S1 APARTMENT | 0.0 | 11.58 | 0.00 | 3.05 | 17.37 | 3.81 | 4.57 | 1 | 1 | 2 | 11.58 | 23.16 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 16 | M S2 APARTMENT | 0.0 | 23.16 | 0.00 | 3.05 | 28.95 | 3.81 | 4.57 | 1 | 1 | 2 | 23.16 | 34.75 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 17 | T SW APARTMENT | 0.0 | 0.00 | 0.00 | 9.14 | 5.79 | 3.81 | 10.67 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 18 | T NW APARTMENT | 0.0 | 0.00 | 9.30 | 9.14 | 5.79 | 13.11 | 10.67 | 1 | 1 | 1 | 0.00 | 11.58 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 19 | T SE APARTMENT | 0.0 | 34.75 | 0.00 | 9.14 | 40.54 | 3.81 | 10.67 | 1 | 1 | 1 | 34.75 | 46.33 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 20 | T NE APARTMENT | 0.0 | 34.75 | 9.30 | 9.14 | 40.54 | 13.11 | 10.67 | 1 | 1 | 1 | 34.75 | 46.33 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 21 | T N1 APARTMENT | 0.0 | 11.58 | 9.30 | 9.14 | 17.37 | 13.11 | 10.67 | 1 | 1 | 1 | 11.58 | 23.16 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 22 | T N2 APARTMENT | 0.0 | 23.16 | 9.30 | 9.14 | 28.95 | 13.11 | 10.67 | 1 | 1 | 1 | 23.16 | 34.75 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 23 | T S1 APARTMENT | 0.0 | 11.58 | 0.00 | 9.14 | 17.37 | 3.81 | 10.67 | 1 | 1 | 1 | 11.58 | 23.16 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 24 | T S2 APARTMENT | 0.0 | 23.16 | 0.00 | 9.14 | 28.95 | 3.81 | 10.67 | 1 | 1 | 1 | 23.16 | 34.75 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 25 | T CORRIDOR | 0.0 | 0.00 | 7.62 | 9.14 | 23.16 | 8.46 | 10.67 | 1 | 1 | 1 | 0.00 | 46.33 | 7.62 | 9.30 | 9.14 | 12.19 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 9.10 | 1.11 | 12 | 1 | 0 | Yes |
| 26 | G CORRIDOR | 0.0 | 0.00 | 7.62 | 0.00 | 23.16 | 8.46 | 1.52 | 1 | 1 | 1 | 0.00 | 46.33 | 7.62 | 9.30 | 0.00 | 3.05 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 6.90 | 3.32 | 12 | 1 | 0 | Yes |
| 27 | M CORRIDOR | 0.0 | 0.00 | 7.62 | 3.05 | 23.16 | 8.46 | 4.57 | 1 | 1 | 2 | 0.00 | 46.33 | 7.62 | 9.30 | 3.05 | 6.10 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 9.10 | 1.11 | 12 | 1 | 0 | Yes |
| Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
| 1 | G SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 2 | G NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 3 | OFFICE | 88.25 | 4.7 | 18.581 | 5.382E-002 | 7.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 14.160 | No |
| 4 | G NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 5 | G N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 6 | G N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 7 | G S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 8 | G S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 9 | M SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 10 | M NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 11 | M SE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 12 | M NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 13 | M N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 14 | M N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 15 | M S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 16 | M S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 17 | T SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 18 | T NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 19 | T SE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 20 | T NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 21 | T N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 22 | T N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 23 | T S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 24 | T S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 25 | T CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 5.287 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.287 | No |
| 26 | G CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 5.287 | 515.392 | 0.000 | 0.000 | 0.000 | 0.000 | 520.679 | No |
| 27 | M CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 5.287 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.287 | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
| 1 | OCCUP_GSW | OCC_APT_SCH_WORKING_FAMILY | G SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 2 | OCCUP_GNW | OCC_APT_SCH_STAY_HOME_FAMILY | G NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 3 | OCCUP_OFFICE | OCC_OFF_W_SB_SCH | OFFICE | 88.25 | 4.7 | 4.7 | 5.382E-002 | 18.581 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 5 |
| 4 | OCCUP_GNE | OCC_APT_SCH_STAY_HOME_FAMILY | G NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 5 | OCCUP_GN1 | OCC_APT_SCH_STAY_HOME_FAMILY | G N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 6 | OCCUP_GN2 | OCC_APT_SCH_STAY_HOME_FAMILY | G N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 7 | OCCUP_GS1 | OCC_APT_SCH_WORKING_FAMILY | G S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 8 | OCCUP_GS2 | OCC_APT_SCH_WORKING_FAMILY | G S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 9 | OCCUP_MSW | OCC_APT_SCH_WORKING_FAMILY | M SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 10 | OCCUP_MNW | OCC_APT_SCH_STAY_HOME_FAMILY | M NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 11 | OCCUP_MSE | OCC_APT_SCH_WORKING_FAMILY | M SE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 12 | OCCUP_MNE | OCC_APT_SCH_STAY_HOME_FAMILY | M NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 13 | OCCUP_MN1 | OCC_APT_SCH_STAY_HOME_FAMILY | M N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 14 | OCCUP_MN2 | OCC_APT_SCH_STAY_HOME_FAMILY | M N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 15 | OCCUP_MS1 | OCC_APT_SCH_WORKING_FAMILY | M S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 16 | OCCUP_MS2 | OCC_APT_SCH_WORKING_FAMILY | M S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 17 | OCCUP_TSW | OCC_APT_SCH_WORKING_FAMILY | T SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 18 | OCCUP_TNW | OCC_APT_SCH_STAY_HOME_FAMILY | T NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 19 | OCCUP_TSE | OCC_APT_SCH_WORKING_FAMILY | T SE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 20 | OCCUP_TNE | OCC_APT_SCH_STAY_HOME_FAMILY | T NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 21 | OCCUP_TN1 | OCC_APT_SCH_STAY_HOME_FAMILY | T N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 22 | OCCUP_TN2 | OCC_APT_SCH_STAY_HOME_FAMILY | T N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 23 | OCCUP_TS1 | OCC_APT_SCH_WORKING_FAMILY | T S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 24 | OCCUP_TS2 | OCC_APT_SCH_WORKING_FAMILY | T S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 25 | OCCUP_T CORRIDOR | OCC_APT_SCH_CORRIDOR | T CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| 26 | OCCUP_G CORRIDOR | OCC_APT_SCH_CORRIDOR | G CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| 27 | OCCUP_M CORRIDOR | OCC_APT_SCH_CORRIDOR | M CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
| 1 | LIGHTING_HARDWIRED_GSW | LTG_SCH_APARTMENT_HARDWIRED | G SW APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 2 | LIGHTING_HARDWIRED_GNW | LTG_SCH_APARTMENT_HARDWIRED | G NW APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 3 | LIGHTING_HARDWIRED_OFFICE | LTG_SCH_OFFICE | OFFICE | 88.25 | 4.7 | 660.945 | 7.490 | 139.160 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 660.945 |
| 4 | LIGHTING_HARDWIRED_GNE | LTG_SCH_APARTMENT_HARDWIRED | G NE APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 5 | LIGHTING_HARDWIRED_GN1 | LTG_SCH_APARTMENT_HARDWIRED | G N1 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 6 | LIGHTING_HARDWIRED_GN2 | LTG_SCH_APARTMENT_HARDWIRED | G N2 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 7 | LIGHTING_HARDWIRED_GS1 | LTG_SCH_APARTMENT_HARDWIRED | G S1 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 8 | LIGHTING_HARDWIRED_GS2 | LTG_SCH_APARTMENT_HARDWIRED | G S2 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 9 | LIGHTING_HARDWIRED_MSW | LTG_SCH_APARTMENT_HARDWIRED | M SW APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 10 | LIGHTING_HARDWIRED_MNW | LTG_SCH_APARTMENT_HARDWIRED | M NW APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 11 | LIGHTING_HARDWIRED_MSE | LTG_SCH_APARTMENT_HARDWIRED | M SE APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 12 | LIGHTING_HARDWIRED_MNE | LTG_SCH_APARTMENT_HARDWIRED | M NE APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 13 | LIGHTING_HARDWIRED_MN1 | LTG_SCH_APARTMENT_HARDWIRED | M N1 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 14 | LIGHTING_HARDWIRED_MN2 | LTG_SCH_APARTMENT_HARDWIRED | M N2 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 15 | LIGHTING_HARDWIRED_MS1 | LTG_SCH_APARTMENT_HARDWIRED | M S1 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 16 | LIGHTING_HARDWIRED_MS2 | LTG_SCH_APARTMENT_HARDWIRED | M S2 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 17 | LIGHTING_HARDWIRED_TSW | LTG_SCH_APARTMENT_HARDWIRED | T SW APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 18 | LIGHTING_HARDWIRED_TNW | LTG_SCH_APARTMENT_HARDWIRED | T NW APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 19 | LIGHTING_HARDWIRED_TSE | LTG_SCH_APARTMENT_HARDWIRED | T SE APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 20 | LIGHTING_HARDWIRED_TNE | LTG_SCH_APARTMENT_HARDWIRED | T NE APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 21 | LIGHTING_HARDWIRED_TN1 | LTG_SCH_APARTMENT_HARDWIRED | T N1 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 22 | LIGHTING_HARDWIRED_TN2 | LTG_SCH_APARTMENT_HARDWIRED | T N2 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 23 | LIGHTING_HARDWIRED_TS1 | LTG_SCH_APARTMENT_HARDWIRED | T S1 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 24 | LIGHTING_HARDWIRED_TS2 | LTG_SCH_APARTMENT_HARDWIRED | T S2 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 25 | LIGHTING_HARDWIRED_GC | LTG_SCH_CORRIDOR | G CORRIDOR | 77.66 | 4.2 | 410.594 | 5.287 | 98.228 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 410.594 |
| 26 | LIGHTING_HARDWIRED_MC | LTG_SCH_CORRIDOR | M CORRIDOR | 77.66 | 4.2 | 410.594 | 5.287 | 98.228 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 410.594 |
| 27 | LIGHTING_HARDWIRED_TC | LTG_SCH_CORRIDOR | T CORRIDOR | 77.66 | 4.2 | 410.594 | 5.287 | 98.228 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 410.594 |
| 28 | LIGHTING_PLUGIN_GSW | LTG_SCH_APARTMENT_PLUGIN | G SW APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 29 | LIGHTING_PLUGIN_GNW | LTG_SCH_APARTMENT_PLUGIN | G NW APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 30 | LIGHTING_PLUGIN_GNE | LTG_SCH_APARTMENT_PLUGIN | G NE APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 31 | LIGHTING_PLUGIN_GN1 | LTG_SCH_APARTMENT_PLUGIN | G N1 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 32 | LIGHTING_PLUGIN_GN2 | LTG_SCH_APARTMENT_PLUGIN | G N2 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 33 | LIGHTING_PLUGIN_GS1 | LTG_SCH_APARTMENT_PLUGIN | G S1 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 34 | LIGHTING_PLUGIN_GS2 | LTG_SCH_APARTMENT_PLUGIN | G S2 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 35 | LIGHTING_PLUGIN_MSW | LTG_SCH_APARTMENT_PLUGIN | M SW APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 36 | LIGHTING_PLUGIN_MNW | LTG_SCH_APARTMENT_PLUGIN | M NW APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 37 | LIGHTING_PLUGIN_MSE | LTG_SCH_APARTMENT_PLUGIN | M SE APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 38 | LIGHTING_PLUGIN_MNE | LTG_SCH_APARTMENT_PLUGIN | M NE APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 39 | LIGHTING_PLUGIN_MN1 | LTG_SCH_APARTMENT_PLUGIN | M N1 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 40 | LIGHTING_PLUGIN_MN2 | LTG_SCH_APARTMENT_PLUGIN | M N2 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 41 | LIGHTING_PLUGIN_MS1 | LTG_SCH_APARTMENT_PLUGIN | M S1 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 42 | LIGHTING_PLUGIN_MS2 | LTG_SCH_APARTMENT_PLUGIN | M S2 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 43 | LIGHTING_PLUGIN_TSW | LTG_SCH_APARTMENT_PLUGIN | T SW APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 44 | LIGHTING_PLUGIN_TNW | LTG_SCH_APARTMENT_PLUGIN | T NW APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 45 | LIGHTING_PLUGIN_TSE | LTG_SCH_APARTMENT_PLUGIN | T SE APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 46 | LIGHTING_PLUGIN_TNE | LTG_SCH_APARTMENT_PLUGIN | T NE APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 47 | LIGHTING_PLUGIN_TN1 | LTG_SCH_APARTMENT_PLUGIN | T N1 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 48 | LIGHTING_PLUGIN_TN2 | LTG_SCH_APARTMENT_PLUGIN | T N2 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 49 | LIGHTING_PLUGIN_TS1 | LTG_SCH_APARTMENT_PLUGIN | T S1 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 50 | LIGHTING_PLUGIN_TS2 | LTG_SCH_APARTMENT_PLUGIN | T S2 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
| 1 | ELEVATOR_LIFT_RUNNING | ELEVATOR_RUNNING_SCH | G CORRIDOR | 77.66 | 4.2 | 38362.000 | 493.978 | 9177.512 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLift | 0.000 | 2585.215 |
| 2 | ELEVATOR_LIFT_STANDBY | ELEVATOR_STANDBY_SCH | G CORRIDOR | 77.66 | 4.2 | 1600.000 | 20.603 | 382.775 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLift | 1187.152 | 1600.000 |
| 3 | ELEVATORS_LIGHTS_FAN | ELEV_LIGHT_FAN_SCH_ADD_DF | G CORRIDOR | 77.66 | 4.2 | 63.000 | 0.811 | 15.072 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLightsFan | 3.150 | 31.500 |
| 4 | PLUG_GSW | EQP_APT_SCH | G SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 5 | PLUG_GNW | EQP_APT_SCH | G NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 6 | PLUG_OFFICE | EQP_OFF_SCH | OFFICE | 88.25 | 4.7 | 588.623 | 6.670 | 123.933 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 588.623 |
| 7 | PLUG_GNE | EQP_APT_SCH | G NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 8 | PLUG_GN1 | EQP_APT_SCH | G N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 9 | PLUG_GN2 | EQP_APT_SCH | G N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 10 | PLUG_GS1 | EQP_APT_SCH | G S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 11 | PLUG_GS2 | EQP_APT_SCH | G S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 12 | PLUG_MSW | EQP_APT_SCH | M SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 13 | PLUG_MNW | EQP_APT_SCH | M NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 14 | PLUG_MSE | EQP_APT_SCH | M SE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 15 | PLUG_MNE | EQP_APT_SCH | M NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 16 | PLUG_MN1 | EQP_APT_SCH | M N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 17 | PLUG_MN2 | EQP_APT_SCH | M N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 18 | PLUG_MS1 | EQP_APT_SCH | M S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 19 | PLUG_MS2 | EQP_APT_SCH | M S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 20 | PLUG_TSW | EQP_APT_SCH | T SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 21 | PLUG_TNW | EQP_APT_SCH | T NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 22 | PLUG_TSE | EQP_APT_SCH | T SE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 23 | PLUG_TNE | EQP_APT_SCH | T NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 24 | PLUG_TN1 | EQP_APT_SCH | T N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 25 | PLUG_TN2 | EQP_APT_SCH | T N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 26 | PLUG_TS1 | EQP_APT_SCH | T S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 27 | PLUG_TS2 | EQP_APT_SCH | T S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
| 1 | PolygonClipping | Periodic | 20 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
| Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
| 1 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | 0.9460 | 53912.0 | 11.449 | 0.4600 |
| Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
| 1 | G SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 2 | GWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 3 | G WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 4 | GWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 5 | G NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 6 | G EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 7 | G GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 8 | G CEILIN SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 9 | G INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 10 | G NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 11 | GWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 12 | G WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 13 | GWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 14 | G SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 15 | G EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 16 | G GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 17 | G CEILIN NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 18 | G INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 19 | G SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 20 | GWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 21 | G EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 22 | GWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 23 | G NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 24 | iz-G EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 25 | G GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 26 | G CEILIN SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 27 | G INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 28 | G NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 29 | GWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 30 | G EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 31 | GWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 32 | G SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 33 | iz-G EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 34 | G GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 35 | G CEILIN NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 36 | G INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 37 | G NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 38 | GWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 39 | G SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 40 | G EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 41 | iz-G EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 42 | G GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 43 | G CEILIN N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 44 | G INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 45 | G NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 46 | GWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 47 | G SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 48 | G EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 49 | iz-G EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 50 | G GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 51 | G CEILIN N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 52 | G INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 53 | G SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 54 | GWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 55 | G NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 56 | G EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 57 | iz-G EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 58 | G GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 59 | G CEILIN S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 60 | G INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 61 | G SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 62 | GWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 63 | G NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 64 | G EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 65 | iz-G EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 66 | G GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 67 | G CEILIN S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 68 | G INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 69 | M WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 70 | MWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 71 | M SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 72 | MWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 73 | M NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 74 | M EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 75 | M GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 76 | M CEILIN SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 77 | M INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 78 | M NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 79 | MWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 80 | M WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 81 | MWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 82 | M SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 83 | M EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 84 | M GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 85 | M CEILIN NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 86 | M INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 87 | M EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 88 | MWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 89 | M SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 90 | MWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 91 | M NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 92 | iz-M EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 93 | M GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 94 | M CEILIN SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 95 | M INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 96 | M NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 97 | MWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 98 | M EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 99 | MWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 100 | M SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 101 | iz-M EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 102 | M GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 103 | M CEILIN NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 104 | M INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 105 | M NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 106 | MWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 107 | M SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 108 | M EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 109 | iz-M EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 110 | M GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 111 | M CEILIN N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 112 | M INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 113 | M NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 114 | MWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 115 | M SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 116 | M EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 117 | iz-M EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 118 | M GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 119 | M CEILIN N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 120 | M INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 121 | M SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 122 | MWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 123 | M NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 124 | M EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 125 | iz-M EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 126 | M GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 127 | M CEILIN S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 128 | M INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 129 | M SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 130 | MWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 131 | M NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 132 | M EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 133 | iz-M EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 134 | M GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 135 | M CEILIN S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 136 | M INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 137 | T WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 138 | TWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 139 | T SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 140 | TWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 141 | T NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 142 | T EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 143 | T GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 144 | T ROOF SWA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 145 | T INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 146 | T NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 147 | TWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 148 | T WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 149 | TWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 150 | T SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 151 | T EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 152 | T GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 153 | T ROOF NWA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 154 | T INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 155 | T EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 156 | TWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 157 | T SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 158 | TWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 159 | T NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 160 | iz-T EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 161 | T GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 162 | T ROOF SEA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 163 | T INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 164 | T NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 165 | TWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 166 | T EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 167 | TWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 168 | T SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 169 | iz-T EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 170 | T GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 171 | T ROOF NEA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 172 | T INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 173 | T NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 174 | TWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 175 | T SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 176 | T EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 177 | iz-T EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 178 | T GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 179 | T ROOF N1A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 180 | T INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 181 | T NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 182 | TWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 183 | T SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 184 | T EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 185 | iz-T EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 186 | T GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 187 | T ROOF N2A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 188 | T INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 189 | T SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 190 | TWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 191 | T NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 192 | T EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 193 | iz-T EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 194 | T GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 195 | T ROOF S1A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 196 | T INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 197 | T SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 198 | TWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 199 | T NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 200 | T EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 201 | iz-T EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 202 | T GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 203 | T ROOF S2A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 204 | T INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 205 | T WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 206 | T EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 207 | TWINDOW14 | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 2 | No | No |
| 208 | iz-T NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 209 | iz-T NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 210 | iz-T NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 211 | iz-T NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 212 | iz-T SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 213 | iz-T SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 214 | iz-T SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 215 | iz-T SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 216 | T FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 217 | T ROOF C | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 218 | G WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 4 | No | No |
| 219 | G EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 4 | No | No |
| 220 | ENTRANCE DOOR | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 1 | No | No |
| 221 | iz-G NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 222 | iz-G NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 223 | iz-G NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 224 | iz-G NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 225 | iz-G SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 226 | iz-G SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 227 | iz-G SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 228 | iz-G SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 229 | G FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 230 | G CEILING C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 231 | M WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 4 | No | No |
| 232 | M EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 233 | MWINDOW14 | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 2 | No | No |
| 234 | iz-M NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 235 | iz-M NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 236 | iz-M NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 237 | iz-M NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 238 | iz-M SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 239 | iz-M SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 240 | iz-M SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 241 | iz-M SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 242 | M FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 243 | M CEILING C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
| 1 | INFIL_GSW | INF_APT_SCH | G SW APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 2 | INFIL_GNW | INF_APT_SCH | G NW APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 3 | INFIL_OFFICE | INF_OFF_SCH | OFFICE | 88.25 | 4.7 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 4 | INFIL_GNE | INF_APT_SCH | G NE APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 5 | INFIL_GN1 | INF_APT_SCH | G N1 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 6 | INFIL_GN2 | INF_APT_SCH | G N2 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 7 | INFIL_GS1 | INF_APT_SCH | G S1 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 8 | INFIL_GS2 | INF_APT_SCH | G S2 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 9 | INFIL_MSW | INF_APT_SCH | M SW APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 10 | INFIL_MNW | INF_APT_SCH | M NW APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 11 | INFIL_MSE | INF_APT_SCH | M SE APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 12 | INFIL_MNE | INF_APT_SCH | M NE APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 13 | INFIL_MN1 | INF_APT_SCH | M N1 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 14 | INFIL_MN2 | INF_APT_SCH | M N2 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 15 | INFIL_MS1 | INF_APT_SCH | M S1 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 16 | INFIL_MS2 | INF_APT_SCH | M S2 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 17 | INFIL_SW | INF_APT_SCH | T SW APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 1.022E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 18 | INFIL_NW | INF_APT_SCH | T NW APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 1.022E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 19 | INFIL_SE | INF_APT_SCH | T SE APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 1.022E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 20 | INFIL_NE | INF_APT_SCH | T NE APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 1.022E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 21 | INFIL_TN1 | INF_APT_SCH | T N1 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 7.323E-005 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 22 | INFIL_TN2 | INF_APT_SCH | T N2 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 7.323E-005 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 23 | INFIL_TS1 | INF_APT_SCH | T S1 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 7.323E-005 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 24 | INFIL_TS2 | INF_APT_SCH | T S2 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 7.323E-005 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 25 | INFIL_GC | INF_COR_SCH | G CORRIDOR | 77.66 | 4.2 | 2.619E-003 | 3.372E-005 | 2.563E-004 | 3.983E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| 26 | DOOR_INFIL_GC | INFIL_DOOR_OPENING_SCH | G CORRIDOR | 77.66 | 4.2 | 0.521 | 6.703E-003 | 5.094E-002 | 7.917 | 1.000 | 0.000 | 0.000 | 0.000 |
| 27 | INFIL_MC | INF_COR_SCH | M CORRIDOR | 77.66 | 4.2 | 2.619E-003 | 3.372E-005 | 2.563E-004 | 3.983E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| 28 | INFIL_TC | INF_COR_SCH | T CORRIDOR | 77.66 | 4.2 | 2.619E-003 | 3.372E-005 | 2.980E-005 | 3.983E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
| 1 | G SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 2 | G NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 3 | G NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 4 | G N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 5 | G N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 6 | G S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 7 | G S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 8 | M SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 9 | M NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 10 | M SE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M SE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 11 | M NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 12 | M N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 13 | M N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 14 | M S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 15 | M S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 16 | T SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 17 | T NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 18 | T SE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T SE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 19 | T NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 20 | T N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 21 | T N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 22 | T S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 23 | T S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| Simple | |
| 1 | Simple |
| Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
| 1 | G SW APARTMENT | Mixing/Well-Stirred |
| 2 | G NW APARTMENT | Mixing/Well-Stirred |
| 3 | OFFICE | Mixing/Well-Stirred |
| 4 | G NE APARTMENT | Mixing/Well-Stirred |
| 5 | G N1 APARTMENT | Mixing/Well-Stirred |
| 6 | G N2 APARTMENT | Mixing/Well-Stirred |
| 7 | G S1 APARTMENT | Mixing/Well-Stirred |
| 8 | G S2 APARTMENT | Mixing/Well-Stirred |
| 9 | M SW APARTMENT | Mixing/Well-Stirred |
| 10 | M NW APARTMENT | Mixing/Well-Stirred |
| 11 | M SE APARTMENT | Mixing/Well-Stirred |
| 12 | M NE APARTMENT | Mixing/Well-Stirred |
| 13 | M N1 APARTMENT | Mixing/Well-Stirred |
| 14 | M N2 APARTMENT | Mixing/Well-Stirred |
| 15 | M S1 APARTMENT | Mixing/Well-Stirred |
| 16 | M S2 APARTMENT | Mixing/Well-Stirred |
| 17 | T SW APARTMENT | Mixing/Well-Stirred |
| 18 | T NW APARTMENT | Mixing/Well-Stirred |
| 19 | T SE APARTMENT | Mixing/Well-Stirred |
| 20 | T NE APARTMENT | Mixing/Well-Stirred |
| 21 | T N1 APARTMENT | Mixing/Well-Stirred |
| 22 | T N2 APARTMENT | Mixing/Well-Stirred |
| 23 | T S1 APARTMENT | Mixing/Well-Stirred |
| 24 | T S2 APARTMENT | Mixing/Well-Stirred |
| 25 | T CORRIDOR | Mixing/Well-Stirred |
| 26 | G CORRIDOR | Mixing/Well-Stirred |
| 27 | M CORRIDOR | Mixing/Well-Stirred |
| No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
| 1 | NoMultizoneOrDistribution |
| Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
| 1 | 1.000 | 1.000 | 1.000 | 1.000 |
| Value | |
| 1 | 6 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.2000 |
| 2 | Zone G SW APARTMENT | 1.2000 |
| 3 | Zone G NW APARTMENT | 1.2000 |
| 4 | Zone OFFICE | 1.2000 |
| 5 | Zone G NE APARTMENT | 1.2000 |
| 6 | Zone G N1 APARTMENT | 1.2000 |
| 7 | Zone G N2 APARTMENT | 1.2000 |
| 8 | Zone G S1 APARTMENT | 1.2000 |
| 9 | Zone G S2 APARTMENT | 1.2000 |
| 10 | Zone M SW APARTMENT | 1.2000 |
| 11 | Zone M NW APARTMENT | 1.2000 |
| 12 | Zone M SE APARTMENT | 1.2000 |
| 13 | Zone M NE APARTMENT | 1.2000 |
| 14 | Zone M N1 APARTMENT | 1.2000 |
| 15 | Zone M N2 APARTMENT | 1.2000 |
| 16 | Zone M S1 APARTMENT | 1.2000 |
| 17 | Zone M S2 APARTMENT | 1.2000 |
| 18 | Zone T SW APARTMENT | 1.2000 |
| 19 | Zone T NW APARTMENT | 1.2000 |
| 20 | Zone T SE APARTMENT | 1.2000 |
| 21 | Zone T NE APARTMENT | 1.2000 |
| 22 | Zone T N1 APARTMENT | 1.2000 |
| 23 | Zone T N2 APARTMENT | 1.2000 |
| 24 | Zone T S1 APARTMENT | 1.2000 |
| 25 | Zone T S2 APARTMENT | 1.2000 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.2000 |
| 2 | Zone G SW APARTMENT | 1.2000 |
| 3 | Zone G NW APARTMENT | 1.2000 |
| 4 | Zone OFFICE | 1.2000 |
| 5 | Zone G NE APARTMENT | 1.2000 |
| 6 | Zone G N1 APARTMENT | 1.2000 |
| 7 | Zone G N2 APARTMENT | 1.2000 |
| 8 | Zone G S1 APARTMENT | 1.2000 |
| 9 | Zone G S2 APARTMENT | 1.2000 |
| 10 | Zone M SW APARTMENT | 1.2000 |
| 11 | Zone M NW APARTMENT | 1.2000 |
| 12 | Zone M SE APARTMENT | 1.2000 |
| 13 | Zone M NE APARTMENT | 1.2000 |
| 14 | Zone M N1 APARTMENT | 1.2000 |
| 15 | Zone M N2 APARTMENT | 1.2000 |
| 16 | Zone M S1 APARTMENT | 1.2000 |
| 17 | Zone M S2 APARTMENT | 1.2000 |
| 18 | Zone T SW APARTMENT | 1.2000 |
| 19 | Zone T NW APARTMENT | 1.2000 |
| 20 | Zone T SE APARTMENT | 1.2000 |
| 21 | Zone T NE APARTMENT | 1.2000 |
| 22 | Zone T N1 APARTMENT | 1.2000 |
| 23 | Zone T N2 APARTMENT | 1.2000 |
| 24 | Zone T S1 APARTMENT | 1.2000 |
| 25 | Zone T S2 APARTMENT | 1.2000 |
| Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
| 1 | G SW APARTMENT | Cooling | 3699.58667 | 4439.50400 | 0.26067 | 0.31280 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 2 | G SW APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 3 | G NW APARTMENT | Cooling | 3738.25905 | 4485.91086 | 0.26345 | 0.31614 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 4 | G NW APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 5 | OFFICE | Cooling | 4226.04254 | 5071.25105 | 0.31023 | 0.37227 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 09:20:00 | 31.00667 | 1.71502E-002 | 88.24927 | 4.74953 | 3.81060E-002 | 0.00000 |
| 6 | OFFICE | Heating | 0.00000 | 0.00000 | 0.00000 | 3.81060E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 4.74953 | 3.81060E-002 | 0.00000 | |
| 7 | G NE APARTMENT | Cooling | 3515.29049 | 4218.34859 | 0.24737 | 0.29685 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 8 | G NE APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 9 | G N1 APARTMENT | Cooling | 3135.40972 | 3762.49166 | 0.21983 | 0.26379 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 10 | G N1 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 11 | G N2 APARTMENT | Cooling | 3130.96437 | 3757.15725 | 0.21951 | 0.26341 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 12 | G N2 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 13 | G S1 APARTMENT | Cooling | 3098.85801 | 3718.62961 | 0.21721 | 0.26065 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 14 | G S1 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 15 | G S2 APARTMENT | Cooling | 3130.17566 | 3756.21079 | 0.21947 | 0.26336 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 16 | G S2 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 17 | M SW APARTMENT | Cooling | 8148.18052 | 9777.81662 | 0.57544 | 0.69052 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 18 | M SW APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 5.19091E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 | |
| 19 | M NW APARTMENT | Cooling | 8230.34829 | 9876.41795 | 0.58139 | 0.69767 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 20 | M NW APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 5.19091E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 | |
| 21 | M SE APARTMENT | Cooling | 7597.49071 | 9116.98885 | 0.53555 | 0.64266 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 22 | M SE APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 5.19091E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 | |
| 23 | M NE APARTMENT | Cooling | 7680.70013 | 9216.84015 | 0.54152 | 0.64982 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 24 | M NE APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 5.19091E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 | |
| 25 | M N1 APARTMENT | Cooling | 6851.57139 | 8221.88567 | 0.48181 | 0.57818 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 26 | M N1 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 5.19091E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 | |
| 27 | M N2 APARTMENT | Cooling | 6841.33649 | 8209.60379 | 0.48107 | 0.57729 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 28 | M N2 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 5.19091E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 | |
| 29 | M S1 APARTMENT | Cooling | 6769.38149 | 8123.25778 | 0.47588 | 0.57105 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 30 | M S1 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 5.19091E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 | |
| 31 | M S2 APARTMENT | Cooling | 6759.10517 | 8110.92620 | 0.47514 | 0.57016 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 32 | M S2 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 5.19091E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 | |
| 33 | T SW APARTMENT | Cooling | 4378.93223 | 5254.71868 | 0.30968 | 0.37161 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 34 | T SW APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 35 | T NW APARTMENT | Cooling | 4444.75870 | 5333.71044 | 0.31443 | 0.37731 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 36 | T NW APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 37 | T SE APARTMENT | Cooling | 3990.58363 | 4788.70036 | 0.28158 | 0.33790 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 38 | T SE APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 39 | T NE APARTMENT | Cooling | 4056.05903 | 4867.27084 | 0.28632 | 0.34359 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 40 | T NE APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 41 | T N1 APARTMENT | Cooling | 3769.54610 | 4523.45532 | 0.26554 | 0.31864 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 42 | T N1 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 43 | T N2 APARTMENT | Cooling | 3755.53513 | 4506.64216 | 0.26452 | 0.31742 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 44 | T N2 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 45 | T S1 APARTMENT | Cooling | 3703.66362 | 4444.39634 | 0.26076 | 0.31291 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 46 | T S1 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 | |
| 47 | T S2 APARTMENT | Cooling | 3689.63122 | 4427.55746 | 0.25974 | 0.31168 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 31.88500 | 1.71518E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 48 | T S2 APARTMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 2.59546E-002 | 00:10:00 | 20.10000 | 1.47983E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
| 1 | SPLIT GSW | Cooling | Sensible | 4496.42 | 0.31280 | 0.31280 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 2 | SPLIT GSW | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 3 | SPLIT GNW | Cooling | Sensible | 4542.21 | 0.31614 | 0.31614 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 4 | SPLIT GNW | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 5 | SPLIT OFFICE | Cooling | Sensible | 5324.94 | 0.37227 | 0.37227 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 6 | SPLIT OFFICE | Heating | Sensible | 917.13 | 3.81060E-002 | 3.81060E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 7 | SPLIT GNE | Cooling | Sensible | 4277.98 | 0.29685 | 0.29685 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 8 | SPLIT GNE | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 9 | SPLIT GN1 | Cooling | Sensible | 3825.73 | 0.26379 | 0.26379 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 10 | SPLIT GN1 | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 11 | SPLIT GN2 | Cooling | Sensible | 3820.47 | 0.26341 | 0.26341 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 12 | SPLIT GN2 | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 13 | SPLIT GS1 | Cooling | Sensible | 3782.44 | 0.26065 | 0.26065 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 14 | SPLIT GS1 | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 15 | SPLIT GS2 | Cooling | Sensible | 3819.51 | 0.26336 | 0.26336 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 16 | SPLIT GS2 | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 17 | SPLIT MSW | Cooling | Sensible | 9881.64 | 0.69052 | 0.69052 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 18 | SPLIT MSW | Heating | Sensible | 1249.34 | 5.19091E-002 | 5.19091E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 19 | SPLIT MNW | Cooling | Sensible | 9979.43 | 0.69767 | 0.69767 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 20 | SPLIT MNW | Heating | Sensible | 1249.34 | 5.19091E-002 | 5.19091E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 21 | SPLIT MSE | Cooling | Sensible | 9227.19 | 0.64266 | 0.64266 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 22 | SPLIT MSE | Heating | Sensible | 1249.34 | 5.19091E-002 | 5.19091E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 23 | SPLIT MNE | Cooling | Sensible | 9325.57 | 0.64982 | 0.64982 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 24 | SPLIT MNE | Heating | Sensible | 1249.34 | 5.19091E-002 | 5.19091E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 25 | SPLIT MN1 | Cooling | Sensible | 8343.62 | 0.57818 | 0.57818 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 26 | SPLIT MN1 | Heating | Sensible | 1249.34 | 5.19091E-002 | 5.19091E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 27 | SPLIT MN2 | Cooling | Sensible | 8331.46 | 0.57729 | 0.57729 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 28 | SPLIT MN2 | Heating | Sensible | 1249.34 | 5.19091E-002 | 5.19091E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 29 | SPLIT MS1 | Cooling | Sensible | 8245.91 | 0.57105 | 0.57105 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 30 | SPLIT MS1 | Heating | Sensible | 1249.34 | 5.19091E-002 | 5.19091E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 31 | SPLIT MS2 | Cooling | Sensible | 8233.68 | 0.57016 | 0.57016 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 32 | SPLIT MS2 | Heating | Sensible | 1249.34 | 5.19091E-002 | 5.19091E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 33 | SPLIT TSW | Cooling | Sensible | 5302.75 | 0.37161 | 0.37161 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 34 | SPLIT TSW | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 35 | SPLIT TNW | Cooling | Sensible | 5380.76 | 0.37731 | 0.37731 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 36 | SPLIT TNW | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 37 | SPLIT TSE | Cooling | Sensible | 4842.01 | 0.33790 | 0.33790 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 38 | SPLIT TSE | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 39 | SPLIT TNE | Cooling | Sensible | 4919.77 | 0.34359 | 0.34359 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 40 | SPLIT TNE | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 41 | SPLIT TN1 | Cooling | Sensible | 4579.28 | 0.31864 | 0.31864 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 42 | SPLIT TN1 | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 43 | SPLIT TN2 | Cooling | Sensible | 4562.61 | 0.31742 | 0.31742 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 44 | SPLIT TN2 | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 45 | SPLIT TS1 | Cooling | Sensible | 4500.90 | 0.31291 | 0.31291 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 46 | SPLIT TS1 | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| 47 | SPLIT TS2 | Cooling | Sensible | 4484.20 | 0.31168 | 0.31168 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
| 48 | SPLIT TS2 | Heating | Sensible | 624.67 | 2.59546E-002 | 2.59546E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
| Component Type | Component Name | Input Field Description | Value | |
| 1 | ZoneHVAC:EnergyRecoveryVentilator | G SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 2 | ZoneHVAC:EnergyRecoveryVentilator | G SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 3 | Fan:OnOff | G SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 4 | Fan:OnOff | G SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 5 | HeatExchanger:AirToAir:SensibleAndLatent | G SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 6 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.31280 |
| 7 | ZoneHVAC:EnergyRecoveryVentilator | G NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 8 | ZoneHVAC:EnergyRecoveryVentilator | G NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 9 | Fan:OnOff | G NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 10 | Fan:OnOff | G NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 11 | HeatExchanger:AirToAir:SensibleAndLatent | G NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 12 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.31614 |
| 13 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | OFFICE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.37227 |
| 14 | ZoneHVAC:EnergyRecoveryVentilator | G NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 15 | ZoneHVAC:EnergyRecoveryVentilator | G NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 16 | Fan:OnOff | G NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 17 | Fan:OnOff | G NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 18 | HeatExchanger:AirToAir:SensibleAndLatent | G NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 19 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.29685 |
| 20 | ZoneHVAC:EnergyRecoveryVentilator | G N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 21 | ZoneHVAC:EnergyRecoveryVentilator | G N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 22 | Fan:OnOff | G N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 23 | Fan:OnOff | G N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 24 | HeatExchanger:AirToAir:SensibleAndLatent | G N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 25 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.26379 |
| 26 | ZoneHVAC:EnergyRecoveryVentilator | G N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 27 | ZoneHVAC:EnergyRecoveryVentilator | G N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 28 | Fan:OnOff | G N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 29 | Fan:OnOff | G N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 30 | HeatExchanger:AirToAir:SensibleAndLatent | G N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 31 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.26341 |
| 32 | ZoneHVAC:EnergyRecoveryVentilator | G S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 33 | ZoneHVAC:EnergyRecoveryVentilator | G S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 34 | Fan:OnOff | G S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 35 | Fan:OnOff | G S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 36 | HeatExchanger:AirToAir:SensibleAndLatent | G S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 37 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.26065 |
| 38 | ZoneHVAC:EnergyRecoveryVentilator | G S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 39 | ZoneHVAC:EnergyRecoveryVentilator | G S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 40 | Fan:OnOff | G S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 41 | Fan:OnOff | G S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 42 | HeatExchanger:AirToAir:SensibleAndLatent | G S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 43 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.26336 |
| 44 | ZoneHVAC:EnergyRecoveryVentilator | M SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 45 | ZoneHVAC:EnergyRecoveryVentilator | M SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 46 | Fan:OnOff | M SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 47 | Fan:OnOff | M SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 48 | HeatExchanger:AirToAir:SensibleAndLatent | M SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 49 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.69052 |
| 50 | ZoneHVAC:EnergyRecoveryVentilator | M NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 51 | ZoneHVAC:EnergyRecoveryVentilator | M NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 52 | Fan:OnOff | M NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 53 | Fan:OnOff | M NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 54 | HeatExchanger:AirToAir:SensibleAndLatent | M NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 55 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.69767 |
| 56 | ZoneHVAC:EnergyRecoveryVentilator | M SE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 57 | ZoneHVAC:EnergyRecoveryVentilator | M SE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 58 | Fan:OnOff | M SE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 59 | Fan:OnOff | M SE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 60 | HeatExchanger:AirToAir:SensibleAndLatent | M SE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 61 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M SE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.64266 |
| 62 | ZoneHVAC:EnergyRecoveryVentilator | M NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 63 | ZoneHVAC:EnergyRecoveryVentilator | M NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 64 | Fan:OnOff | M NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 65 | Fan:OnOff | M NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 66 | HeatExchanger:AirToAir:SensibleAndLatent | M NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 67 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.64982 |
| 68 | ZoneHVAC:EnergyRecoveryVentilator | M N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 69 | ZoneHVAC:EnergyRecoveryVentilator | M N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 70 | Fan:OnOff | M N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 71 | Fan:OnOff | M N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 72 | HeatExchanger:AirToAir:SensibleAndLatent | M N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 73 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.57818 |
| 74 | ZoneHVAC:EnergyRecoveryVentilator | M N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 75 | ZoneHVAC:EnergyRecoveryVentilator | M N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 76 | Fan:OnOff | M N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 77 | Fan:OnOff | M N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 78 | HeatExchanger:AirToAir:SensibleAndLatent | M N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 79 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.57729 |
| 80 | ZoneHVAC:EnergyRecoveryVentilator | M S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 81 | ZoneHVAC:EnergyRecoveryVentilator | M S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 82 | Fan:OnOff | M S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 83 | Fan:OnOff | M S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 84 | HeatExchanger:AirToAir:SensibleAndLatent | M S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 85 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.57105 |
| 86 | ZoneHVAC:EnergyRecoveryVentilator | M S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 87 | ZoneHVAC:EnergyRecoveryVentilator | M S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 88 | Fan:OnOff | M S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 89 | Fan:OnOff | M S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 90 | HeatExchanger:AirToAir:SensibleAndLatent | M S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 91 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.57016 |
| 92 | ZoneHVAC:EnergyRecoveryVentilator | T SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 93 | ZoneHVAC:EnergyRecoveryVentilator | T SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 94 | Fan:OnOff | T SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 95 | Fan:OnOff | T SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 96 | HeatExchanger:AirToAir:SensibleAndLatent | T SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 97 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.37161 |
| 98 | ZoneHVAC:EnergyRecoveryVentilator | T NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 99 | ZoneHVAC:EnergyRecoveryVentilator | T NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 100 | Fan:OnOff | T NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 101 | Fan:OnOff | T NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 102 | HeatExchanger:AirToAir:SensibleAndLatent | T NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 103 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.37731 |
| 104 | ZoneHVAC:EnergyRecoveryVentilator | T SE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 105 | ZoneHVAC:EnergyRecoveryVentilator | T SE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 106 | Fan:OnOff | T SE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 107 | Fan:OnOff | T SE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 108 | HeatExchanger:AirToAir:SensibleAndLatent | T SE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 109 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T SE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.33790 |
| 110 | ZoneHVAC:EnergyRecoveryVentilator | T NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 111 | ZoneHVAC:EnergyRecoveryVentilator | T NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 112 | Fan:OnOff | T NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 113 | Fan:OnOff | T NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 114 | HeatExchanger:AirToAir:SensibleAndLatent | T NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 115 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.34359 |
| 116 | ZoneHVAC:EnergyRecoveryVentilator | T N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 117 | ZoneHVAC:EnergyRecoveryVentilator | T N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 118 | Fan:OnOff | T N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 119 | Fan:OnOff | T N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 120 | HeatExchanger:AirToAir:SensibleAndLatent | T N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 121 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.31864 |
| 122 | ZoneHVAC:EnergyRecoveryVentilator | T N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 123 | ZoneHVAC:EnergyRecoveryVentilator | T N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 124 | Fan:OnOff | T N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 125 | Fan:OnOff | T N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 126 | HeatExchanger:AirToAir:SensibleAndLatent | T N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 127 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.31742 |
| 128 | ZoneHVAC:EnergyRecoveryVentilator | T S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 129 | ZoneHVAC:EnergyRecoveryVentilator | T S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 130 | Fan:OnOff | T S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 131 | Fan:OnOff | T S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 132 | HeatExchanger:AirToAir:SensibleAndLatent | T S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 133 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.31291 |
| 134 | ZoneHVAC:EnergyRecoveryVentilator | T S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 135 | ZoneHVAC:EnergyRecoveryVentilator | T S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 136 | Fan:OnOff | T S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 137 | Fan:OnOff | T S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 138 | HeatExchanger:AirToAir:SensibleAndLatent | T S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 139 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.31168 |
| 140 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.31280 |
| 141 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.31280 |
| 142 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.31280 |
| 143 | AirLoopHVAC | SPLIT GSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.31280 |
| 144 | AirLoopHVAC | SPLIT GSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.31280 |
| 145 | AirLoopHVAC | SPLIT GSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.31280 |
| 146 | AirLoopHVAC | SPLIT GSW | User Heating Air Flow Ratio [] | 1.00000 |
| 147 | AirLoopHVAC | SPLIT GSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 148 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.31614 |
| 149 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.31614 |
| 150 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.31614 |
| 151 | AirLoopHVAC | SPLIT GNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.31614 |
| 152 | AirLoopHVAC | SPLIT GNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.31614 |
| 153 | AirLoopHVAC | SPLIT GNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.31614 |
| 154 | AirLoopHVAC | SPLIT GNW | User Heating Air Flow Ratio [] | 1.00000 |
| 155 | AirLoopHVAC | SPLIT GNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 156 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.37227 |
| 157 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.37227 |
| 158 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.37227 |
| 159 | AirLoopHVAC | SPLIT OFFICE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.37227 |
| 160 | AirLoopHVAC | SPLIT OFFICE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.37227 |
| 161 | AirLoopHVAC | SPLIT OFFICE | Adjusted Main Design Air Flow Rate [m3/s] | 0.37227 |
| 162 | AirLoopHVAC | SPLIT OFFICE | User Heating Air Flow Ratio [] | 1.00000 |
| 163 | AirLoopHVAC | SPLIT OFFICE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 164 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.29685 |
| 165 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.29685 |
| 166 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.29685 |
| 167 | AirLoopHVAC | SPLIT GNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.29685 |
| 168 | AirLoopHVAC | SPLIT GNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.29685 |
| 169 | AirLoopHVAC | SPLIT GNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.29685 |
| 170 | AirLoopHVAC | SPLIT GNE | User Heating Air Flow Ratio [] | 1.00000 |
| 171 | AirLoopHVAC | SPLIT GNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 172 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.26379 |
| 173 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.26379 |
| 174 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.26379 |
| 175 | AirLoopHVAC | SPLIT GN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.26379 |
| 176 | AirLoopHVAC | SPLIT GN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.26379 |
| 177 | AirLoopHVAC | SPLIT GN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.26379 |
| 178 | AirLoopHVAC | SPLIT GN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 179 | AirLoopHVAC | SPLIT GN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 180 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.26341 |
| 181 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.26341 |
| 182 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.26341 |
| 183 | AirLoopHVAC | SPLIT GN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.26341 |
| 184 | AirLoopHVAC | SPLIT GN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.26341 |
| 185 | AirLoopHVAC | SPLIT GN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.26341 |
| 186 | AirLoopHVAC | SPLIT GN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 187 | AirLoopHVAC | SPLIT GN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 188 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.26065 |
| 189 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.26065 |
| 190 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.26065 |
| 191 | AirLoopHVAC | SPLIT GS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.26065 |
| 192 | AirLoopHVAC | SPLIT GS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.26065 |
| 193 | AirLoopHVAC | SPLIT GS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.26065 |
| 194 | AirLoopHVAC | SPLIT GS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 195 | AirLoopHVAC | SPLIT GS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 196 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.26336 |
| 197 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.26336 |
| 198 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.26336 |
| 199 | AirLoopHVAC | SPLIT GS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.26336 |
| 200 | AirLoopHVAC | SPLIT GS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.26336 |
| 201 | AirLoopHVAC | SPLIT GS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.26336 |
| 202 | AirLoopHVAC | SPLIT GS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 203 | AirLoopHVAC | SPLIT GS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 204 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.69052 |
| 205 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.69052 |
| 206 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.69052 |
| 207 | AirLoopHVAC | SPLIT MSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.69052 |
| 208 | AirLoopHVAC | SPLIT MSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.69052 |
| 209 | AirLoopHVAC | SPLIT MSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.69052 |
| 210 | AirLoopHVAC | SPLIT MSW | User Heating Air Flow Ratio [] | 1.00000 |
| 211 | AirLoopHVAC | SPLIT MSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 212 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.69767 |
| 213 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.69767 |
| 214 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.69767 |
| 215 | AirLoopHVAC | SPLIT MNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.69767 |
| 216 | AirLoopHVAC | SPLIT MNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.69767 |
| 217 | AirLoopHVAC | SPLIT MNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.69767 |
| 218 | AirLoopHVAC | SPLIT MNW | User Heating Air Flow Ratio [] | 1.00000 |
| 219 | AirLoopHVAC | SPLIT MNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 220 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.64266 |
| 221 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.64266 |
| 222 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.64266 |
| 223 | AirLoopHVAC | SPLIT MSE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.64266 |
| 224 | AirLoopHVAC | SPLIT MSE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.64266 |
| 225 | AirLoopHVAC | SPLIT MSE | Adjusted Main Design Air Flow Rate [m3/s] | 0.64266 |
| 226 | AirLoopHVAC | SPLIT MSE | User Heating Air Flow Ratio [] | 1.00000 |
| 227 | AirLoopHVAC | SPLIT MSE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 228 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.64982 |
| 229 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.64982 |
| 230 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.64982 |
| 231 | AirLoopHVAC | SPLIT MNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.64982 |
| 232 | AirLoopHVAC | SPLIT MNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.64982 |
| 233 | AirLoopHVAC | SPLIT MNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.64982 |
| 234 | AirLoopHVAC | SPLIT MNE | User Heating Air Flow Ratio [] | 1.00000 |
| 235 | AirLoopHVAC | SPLIT MNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 236 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.57818 |
| 237 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.57818 |
| 238 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.57818 |
| 239 | AirLoopHVAC | SPLIT MN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.57818 |
| 240 | AirLoopHVAC | SPLIT MN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.57818 |
| 241 | AirLoopHVAC | SPLIT MN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.57818 |
| 242 | AirLoopHVAC | SPLIT MN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 243 | AirLoopHVAC | SPLIT MN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 244 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.57729 |
| 245 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.57729 |
| 246 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.57729 |
| 247 | AirLoopHVAC | SPLIT MN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.57729 |
| 248 | AirLoopHVAC | SPLIT MN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.57729 |
| 249 | AirLoopHVAC | SPLIT MN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.57729 |
| 250 | AirLoopHVAC | SPLIT MN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 251 | AirLoopHVAC | SPLIT MN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 252 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.57105 |
| 253 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.57105 |
| 254 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.57105 |
| 255 | AirLoopHVAC | SPLIT MS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.57105 |
| 256 | AirLoopHVAC | SPLIT MS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.57105 |
| 257 | AirLoopHVAC | SPLIT MS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.57105 |
| 258 | AirLoopHVAC | SPLIT MS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 259 | AirLoopHVAC | SPLIT MS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 260 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.57016 |
| 261 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.57016 |
| 262 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.57016 |
| 263 | AirLoopHVAC | SPLIT MS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.57016 |
| 264 | AirLoopHVAC | SPLIT MS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.57016 |
| 265 | AirLoopHVAC | SPLIT MS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.57016 |
| 266 | AirLoopHVAC | SPLIT MS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 267 | AirLoopHVAC | SPLIT MS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 268 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.37161 |
| 269 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.37161 |
| 270 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.37161 |
| 271 | AirLoopHVAC | SPLIT TSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.37161 |
| 272 | AirLoopHVAC | SPLIT TSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.37161 |
| 273 | AirLoopHVAC | SPLIT TSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.37161 |
| 274 | AirLoopHVAC | SPLIT TSW | User Heating Air Flow Ratio [] | 1.00000 |
| 275 | AirLoopHVAC | SPLIT TSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 276 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.37731 |
| 277 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.37731 |
| 278 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.37731 |
| 279 | AirLoopHVAC | SPLIT TNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.37731 |
| 280 | AirLoopHVAC | SPLIT TNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.37731 |
| 281 | AirLoopHVAC | SPLIT TNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.37731 |
| 282 | AirLoopHVAC | SPLIT TNW | User Heating Air Flow Ratio [] | 1.00000 |
| 283 | AirLoopHVAC | SPLIT TNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 284 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.33790 |
| 285 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.33790 |
| 286 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.33790 |
| 287 | AirLoopHVAC | SPLIT TSE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.33790 |
| 288 | AirLoopHVAC | SPLIT TSE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.33790 |
| 289 | AirLoopHVAC | SPLIT TSE | Adjusted Main Design Air Flow Rate [m3/s] | 0.33790 |
| 290 | AirLoopHVAC | SPLIT TSE | User Heating Air Flow Ratio [] | 1.00000 |
| 291 | AirLoopHVAC | SPLIT TSE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 292 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.34359 |
| 293 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.34359 |
| 294 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.34359 |
| 295 | AirLoopHVAC | SPLIT TNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.34359 |
| 296 | AirLoopHVAC | SPLIT TNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.34359 |
| 297 | AirLoopHVAC | SPLIT TNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.34359 |
| 298 | AirLoopHVAC | SPLIT TNE | User Heating Air Flow Ratio [] | 1.00000 |
| 299 | AirLoopHVAC | SPLIT TNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 300 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.31864 |
| 301 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.31864 |
| 302 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.31864 |
| 303 | AirLoopHVAC | SPLIT TN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.31864 |
| 304 | AirLoopHVAC | SPLIT TN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.31864 |
| 305 | AirLoopHVAC | SPLIT TN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.31864 |
| 306 | AirLoopHVAC | SPLIT TN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 307 | AirLoopHVAC | SPLIT TN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 308 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.31742 |
| 309 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.31742 |
| 310 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.31742 |
| 311 | AirLoopHVAC | SPLIT TN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.31742 |
| 312 | AirLoopHVAC | SPLIT TN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.31742 |
| 313 | AirLoopHVAC | SPLIT TN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.31742 |
| 314 | AirLoopHVAC | SPLIT TN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 315 | AirLoopHVAC | SPLIT TN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 316 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.31291 |
| 317 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.31291 |
| 318 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.31291 |
| 319 | AirLoopHVAC | SPLIT TS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.31291 |
| 320 | AirLoopHVAC | SPLIT TS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.31291 |
| 321 | AirLoopHVAC | SPLIT TS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.31291 |
| 322 | AirLoopHVAC | SPLIT TS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 323 | AirLoopHVAC | SPLIT TS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 324 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.31168 |
| 325 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.31168 |
| 326 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.31168 |
| 327 | AirLoopHVAC | SPLIT TS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.31168 |
| 328 | AirLoopHVAC | SPLIT TS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.31168 |
| 329 | AirLoopHVAC | SPLIT TS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.31168 |
| 330 | AirLoopHVAC | SPLIT TS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 331 | AirLoopHVAC | SPLIT TS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 332 | AirLoopHVAC | SPLIT GSW | Design Supply Air Flow Rate [m3/s] | 0.31280 |
| 333 | AirLoopHVAC | SPLIT GNW | Design Supply Air Flow Rate [m3/s] | 0.31614 |
| 334 | AirLoopHVAC | SPLIT OFFICE | Design Supply Air Flow Rate [m3/s] | 0.37227 |
| 335 | AirLoopHVAC | SPLIT GNE | Design Supply Air Flow Rate [m3/s] | 0.29685 |
| 336 | AirLoopHVAC | SPLIT GN1 | Design Supply Air Flow Rate [m3/s] | 0.26379 |
| 337 | AirLoopHVAC | SPLIT GN2 | Design Supply Air Flow Rate [m3/s] | 0.26341 |
| 338 | AirLoopHVAC | SPLIT GS1 | Design Supply Air Flow Rate [m3/s] | 0.26065 |
| 339 | AirLoopHVAC | SPLIT GS2 | Design Supply Air Flow Rate [m3/s] | 0.26336 |
| 340 | AirLoopHVAC | SPLIT MSW | Design Supply Air Flow Rate [m3/s] | 0.69052 |
| 341 | AirLoopHVAC | SPLIT MNW | Design Supply Air Flow Rate [m3/s] | 0.69767 |
| 342 | AirLoopHVAC | SPLIT MSE | Design Supply Air Flow Rate [m3/s] | 0.64266 |
| 343 | AirLoopHVAC | SPLIT MNE | Design Supply Air Flow Rate [m3/s] | 0.64982 |
| 344 | AirLoopHVAC | SPLIT MN1 | Design Supply Air Flow Rate [m3/s] | 0.57818 |
| 345 | AirLoopHVAC | SPLIT MN2 | Design Supply Air Flow Rate [m3/s] | 0.57729 |
| 346 | AirLoopHVAC | SPLIT MS1 | Design Supply Air Flow Rate [m3/s] | 0.57105 |
| 347 | AirLoopHVAC | SPLIT MS2 | Design Supply Air Flow Rate [m3/s] | 0.57016 |
| 348 | AirLoopHVAC | SPLIT TSW | Design Supply Air Flow Rate [m3/s] | 0.37161 |
| 349 | AirLoopHVAC | SPLIT TNW | Design Supply Air Flow Rate [m3/s] | 0.37731 |
| 350 | AirLoopHVAC | SPLIT TSE | Design Supply Air Flow Rate [m3/s] | 0.33790 |
| 351 | AirLoopHVAC | SPLIT TNE | Design Supply Air Flow Rate [m3/s] | 0.34359 |
| 352 | AirLoopHVAC | SPLIT TN1 | Design Supply Air Flow Rate [m3/s] | 0.31864 |
| 353 | AirLoopHVAC | SPLIT TN2 | Design Supply Air Flow Rate [m3/s] | 0.31742 |
| 354 | AirLoopHVAC | SPLIT TS1 | Design Supply Air Flow Rate [m3/s] | 0.31291 |
| 355 | AirLoopHVAC | SPLIT TS2 | Design Supply Air Flow Rate [m3/s] | 0.31168 |
| 356 | Controller:OutdoorAir | SPLIT GSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.31280 |
| 357 | Controller:OutdoorAir | SPLIT GSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 358 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.31280 |
| 359 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.31280 |
| 360 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.31280 |
| 361 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.31280 |
| 362 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5881.00070 |
| 363 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3940.27047 |
| 364 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 365 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5881.00070 |
| 366 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 367 | Fan:OnOff | SPLIT GSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.31280 |
| 368 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31280 |
| 369 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5881.00070 |
| 370 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80070 |
| 371 | Coil:Heating:DX:SingleSpeed | SPLIT GSW HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31280 |
| 372 | Coil:Heating:DX:SingleSpeed | SPLIT GSW HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5881.00070 |
| 373 | Coil:Heating:Electric | SPLIT GSW_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5881.00070 |
| 374 | Controller:OutdoorAir | SPLIT GNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.31614 |
| 375 | Controller:OutdoorAir | SPLIT GNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 376 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.31614 |
| 377 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.31614 |
| 378 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.31614 |
| 379 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.31614 |
| 380 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5900.19430 |
| 381 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3953.13018 |
| 382 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 383 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5900.19430 |
| 384 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 385 | Fan:OnOff | SPLIT GNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.31614 |
| 386 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31614 |
| 387 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5900.19430 |
| 388 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80009 |
| 389 | Coil:Heating:DX:SingleSpeed | SPLIT GNW HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31614 |
| 390 | Coil:Heating:DX:SingleSpeed | SPLIT GNW HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5900.19430 |
| 391 | Coil:Heating:Electric | SPLIT GNW_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5900.19430 |
| 392 | Controller:OutdoorAir | SPLIT OFFICE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.37227 |
| 393 | Controller:OutdoorAir | SPLIT OFFICE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 3.81060E-002 |
| 394 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.37227 |
| 395 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.37227 |
| 396 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.37227 |
| 397 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.37227 |
| 398 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6944.56513 |
| 399 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 4652.85864 |
| 400 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 401 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 6944.56513 |
| 402 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 403 | Fan:OnOff | SPLIT OFFICE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.37227 |
| 404 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.37227 |
| 405 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6944.56513 |
| 406 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80025 |
| 407 | Coil:Heating:DX:SingleSpeed | SPLIT OFFICE HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.37227 |
| 408 | Coil:Heating:DX:SingleSpeed | SPLIT OFFICE HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 6944.56513 |
| 409 | Coil:Heating:Electric | SPLIT OFFICE_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 6944.56513 |
| 410 | Controller:OutdoorAir | SPLIT GNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.29685 |
| 411 | Controller:OutdoorAir | SPLIT GNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 412 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.29685 |
| 413 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.29685 |
| 414 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.29685 |
| 415 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.29685 |
| 416 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5611.15547 |
| 417 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3759.47417 |
| 418 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 419 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5611.15547 |
| 420 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 421 | Fan:OnOff | SPLIT GNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.29685 |
| 422 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.29685 |
| 423 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5611.15547 |
| 424 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.79897 |
| 425 | Coil:Heating:DX:SingleSpeed | SPLIT GNE HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.29685 |
| 426 | Coil:Heating:DX:SingleSpeed | SPLIT GNE HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5611.15547 |
| 427 | Coil:Heating:Electric | SPLIT GNE_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5611.15547 |
| 428 | Controller:OutdoorAir | SPLIT GN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.26379 |
| 429 | Controller:OutdoorAir | SPLIT GN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 430 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.26379 |
| 431 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.26379 |
| 432 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.26379 |
| 433 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.26379 |
| 434 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5069.02598 |
| 435 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3396.24741 |
| 436 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 437 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5069.02598 |
| 438 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 439 | Fan:OnOff | SPLIT GN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.26379 |
| 440 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.26379 |
| 441 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5069.02598 |
| 442 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.79272 |
| 443 | Coil:Heating:DX:SingleSpeed | SPLIT GN1 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.26379 |
| 444 | Coil:Heating:DX:SingleSpeed | SPLIT GN1 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5069.02598 |
| 445 | Coil:Heating:Electric | SPLIT GN1_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5069.02598 |
| 446 | Controller:OutdoorAir | SPLIT GN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.26341 |
| 447 | Controller:OutdoorAir | SPLIT GN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 448 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.26341 |
| 449 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.26341 |
| 450 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.26341 |
| 451 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.26341 |
| 452 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5063.22232 |
| 453 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3392.35896 |
| 454 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 455 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5063.22232 |
| 456 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 457 | Fan:OnOff | SPLIT GN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.26341 |
| 458 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.26341 |
| 459 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5063.22232 |
| 460 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.79262 |
| 461 | Coil:Heating:DX:SingleSpeed | SPLIT GN2 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.26341 |
| 462 | Coil:Heating:DX:SingleSpeed | SPLIT GN2 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5063.22232 |
| 463 | Coil:Heating:Electric | SPLIT GN2_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5063.22232 |
| 464 | Controller:OutdoorAir | SPLIT GS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.26065 |
| 465 | Controller:OutdoorAir | SPLIT GS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 466 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.26065 |
| 467 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.26065 |
| 468 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.26065 |
| 469 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.26065 |
| 470 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5082.77799 |
| 471 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3405.46125 |
| 472 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 473 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5082.77799 |
| 474 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 475 | Fan:OnOff | SPLIT GS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.26065 |
| 476 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.26065 |
| 477 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5082.77799 |
| 478 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.78610 |
| 479 | Coil:Heating:DX:SingleSpeed | SPLIT GS1 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.26065 |
| 480 | Coil:Heating:DX:SingleSpeed | SPLIT GS1 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5082.77799 |
| 481 | Coil:Heating:Electric | SPLIT GS1_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5082.77799 |
| 482 | Controller:OutdoorAir | SPLIT GS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.26336 |
| 483 | Controller:OutdoorAir | SPLIT GS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 484 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.26336 |
| 485 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.26336 |
| 486 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.26336 |
| 487 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.26336 |
| 488 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5124.92140 |
| 489 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3433.69734 |
| 490 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 491 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5124.92140 |
| 492 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 493 | Fan:OnOff | SPLIT GS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.26336 |
| 494 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.26336 |
| 495 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5124.92140 |
| 496 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.78675 |
| 497 | Coil:Heating:DX:SingleSpeed | SPLIT GS2 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.26336 |
| 498 | Coil:Heating:DX:SingleSpeed | SPLIT GS2 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5124.92140 |
| 499 | Coil:Heating:Electric | SPLIT GS2_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5124.92140 |
| 500 | Controller:OutdoorAir | SPLIT MSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.69052 |
| 501 | Controller:OutdoorAir | SPLIT MSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 502 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.69052 |
| 503 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.69052 |
| 504 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.69052 |
| 505 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.69052 |
| 506 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 12843.65464 |
| 507 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8605.24861 |
| 508 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 509 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 12843.65464 |
| 510 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 511 | Fan:OnOff | SPLIT MSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.69052 |
| 512 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.69052 |
| 513 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 12843.65464 |
| 514 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80021 |
| 515 | Coil:Heating:DX:SingleSpeed | SPLIT MSW HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.69052 |
| 516 | Coil:Heating:DX:SingleSpeed | SPLIT MSW HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 12843.65464 |
| 517 | Coil:Heating:Electric | SPLIT MSW_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 12843.65464 |
| 518 | Controller:OutdoorAir | SPLIT MNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.69767 |
| 519 | Controller:OutdoorAir | SPLIT MNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 520 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.69767 |
| 521 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.69767 |
| 522 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.69767 |
| 523 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.69767 |
| 524 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 12898.90743 |
| 525 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8642.26798 |
| 526 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 527 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 12898.90743 |
| 528 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 529 | Fan:OnOff | SPLIT MNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.69767 |
| 530 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.69767 |
| 531 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 12898.90743 |
| 532 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80018 |
| 533 | Coil:Heating:DX:SingleSpeed | SPLIT MNW HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.69767 |
| 534 | Coil:Heating:DX:SingleSpeed | SPLIT MNW HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 12898.90743 |
| 535 | Coil:Heating:Electric | SPLIT MNW_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 12898.90743 |
| 536 | Controller:OutdoorAir | SPLIT MSE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.64266 |
| 537 | Controller:OutdoorAir | SPLIT MSE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 538 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.64266 |
| 539 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.64266 |
| 540 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.64266 |
| 541 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.64266 |
| 542 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 12146.23195 |
| 543 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8137.97541 |
| 544 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 545 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 12146.23195 |
| 546 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 547 | Fan:OnOff | SPLIT MSE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.64266 |
| 548 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.64266 |
| 549 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 12146.23195 |
| 550 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80001 |
| 551 | Coil:Heating:DX:SingleSpeed | SPLIT MSE HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.64266 |
| 552 | Coil:Heating:DX:SingleSpeed | SPLIT MSE HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 12146.23195 |
| 553 | Coil:Heating:Electric | SPLIT MSE_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 12146.23195 |
| 554 | Controller:OutdoorAir | SPLIT MNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.64982 |
| 555 | Controller:OutdoorAir | SPLIT MNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 556 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.64982 |
| 557 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.64982 |
| 558 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.64982 |
| 559 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.64982 |
| 560 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 12183.91320 |
| 561 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8163.22185 |
| 562 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 563 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 12183.91320 |
| 564 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 565 | Fan:OnOff | SPLIT MNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.64982 |
| 566 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.64982 |
| 567 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 12183.91320 |
| 568 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80059 |
| 569 | Coil:Heating:DX:SingleSpeed | SPLIT MNE HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.64982 |
| 570 | Coil:Heating:DX:SingleSpeed | SPLIT MNE HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 12183.91320 |
| 571 | Coil:Heating:Electric | SPLIT MNE_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 12183.91320 |
| 572 | Controller:OutdoorAir | SPLIT MN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.57818 |
| 573 | Controller:OutdoorAir | SPLIT MN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 574 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.57818 |
| 575 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.57818 |
| 576 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.57818 |
| 577 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.57818 |
| 578 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 10992.23816 |
| 579 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7364.79957 |
| 580 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 581 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 10992.23816 |
| 582 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 583 | Fan:OnOff | SPLIT MN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.57818 |
| 584 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.57818 |
| 585 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 10992.23816 |
| 586 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.79712 |
| 587 | Coil:Heating:DX:SingleSpeed | SPLIT MN1 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.57818 |
| 588 | Coil:Heating:DX:SingleSpeed | SPLIT MN1 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 10992.23816 |
| 589 | Coil:Heating:Electric | SPLIT MN1_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 10992.23816 |
| 590 | Controller:OutdoorAir | SPLIT MN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.57729 |
| 591 | Controller:OutdoorAir | SPLIT MN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 592 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.57729 |
| 593 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.57729 |
| 594 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.57729 |
| 595 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.57729 |
| 596 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 10978.76515 |
| 597 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7355.77265 |
| 598 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 599 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 10978.76515 |
| 600 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 601 | Fan:OnOff | SPLIT MN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.57729 |
| 602 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.57729 |
| 603 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 10978.76515 |
| 604 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.79702 |
| 605 | Coil:Heating:DX:SingleSpeed | SPLIT MN2 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.57729 |
| 606 | Coil:Heating:DX:SingleSpeed | SPLIT MN2 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 10978.76515 |
| 607 | Coil:Heating:Electric | SPLIT MN2_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 10978.76515 |
| 608 | Controller:OutdoorAir | SPLIT MS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.57105 |
| 609 | Controller:OutdoorAir | SPLIT MS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 610 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.57105 |
| 611 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.57105 |
| 612 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.57105 |
| 613 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.57105 |
| 614 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 11000.75005 |
| 615 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7370.50253 |
| 616 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 617 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 11000.75005 |
| 618 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 619 | Fan:OnOff | SPLIT MS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.57105 |
| 620 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.57105 |
| 621 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 11000.75005 |
| 622 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.79093 |
| 623 | Coil:Heating:DX:SingleSpeed | SPLIT MS1 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.57105 |
| 624 | Coil:Heating:DX:SingleSpeed | SPLIT MS1 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 11000.75005 |
| 625 | Coil:Heating:Electric | SPLIT MS1_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 11000.75005 |
| 626 | Controller:OutdoorAir | SPLIT MS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.57016 |
| 627 | Controller:OutdoorAir | SPLIT MS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 628 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.57016 |
| 629 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.57016 |
| 630 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.57016 |
| 631 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.57016 |
| 632 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 10987.56591 |
| 633 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7361.66916 |
| 634 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 635 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 10987.56591 |
| 636 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 637 | Fan:OnOff | SPLIT MS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.57016 |
| 638 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.57016 |
| 639 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 10987.56591 |
| 640 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.79081 |
| 641 | Coil:Heating:DX:SingleSpeed | SPLIT MS2 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.57016 |
| 642 | Coil:Heating:DX:SingleSpeed | SPLIT MS2 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 10987.56591 |
| 643 | Coil:Heating:Electric | SPLIT MS2_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 10987.56591 |
| 644 | Controller:OutdoorAir | SPLIT TSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.37161 |
| 645 | Controller:OutdoorAir | SPLIT TSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 646 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.37161 |
| 647 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.37161 |
| 648 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.37161 |
| 649 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.37161 |
| 650 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6855.57249 |
| 651 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 4593.23357 |
| 652 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 653 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 6855.57249 |
| 654 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 655 | Fan:OnOff | SPLIT TSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.37161 |
| 656 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.37161 |
| 657 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6855.57249 |
| 658 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80090 |
| 659 | Coil:Heating:DX:SingleSpeed | SPLIT TSW HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.37161 |
| 660 | Coil:Heating:DX:SingleSpeed | SPLIT TSW HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 6855.57249 |
| 661 | Coil:Heating:Electric | SPLIT TSW_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 6855.57249 |
| 662 | Controller:OutdoorAir | SPLIT TNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.37731 |
| 663 | Controller:OutdoorAir | SPLIT TNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 664 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.37731 |
| 665 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.37731 |
| 666 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.37731 |
| 667 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.37731 |
| 668 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6925.22664 |
| 669 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 4639.90185 |
| 670 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 671 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 6925.22664 |
| 672 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 673 | Fan:OnOff | SPLIT TNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.37731 |
| 674 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.37731 |
| 675 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6925.22664 |
| 676 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80059 |
| 677 | Coil:Heating:DX:SingleSpeed | SPLIT TNW HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.37731 |
| 678 | Coil:Heating:DX:SingleSpeed | SPLIT TNW HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 6925.22664 |
| 679 | Coil:Heating:Electric | SPLIT TNW_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 6925.22664 |
| 680 | Controller:OutdoorAir | SPLIT TSE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.33790 |
| 681 | Controller:OutdoorAir | SPLIT TSE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 682 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.33790 |
| 683 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.33790 |
| 684 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.33790 |
| 685 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.33790 |
| 686 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6343.60816 |
| 687 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 4250.21747 |
| 688 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 689 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 6343.60816 |
| 690 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 691 | Fan:OnOff | SPLIT TSE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.33790 |
| 692 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.33790 |
| 693 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6343.60816 |
| 694 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80018 |
| 695 | Coil:Heating:DX:SingleSpeed | SPLIT TSE HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.33790 |
| 696 | Coil:Heating:DX:SingleSpeed | SPLIT TSE HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 6343.60816 |
| 697 | Coil:Heating:Electric | SPLIT TSE_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 6343.60816 |
| 698 | Controller:OutdoorAir | SPLIT TNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.34359 |
| 699 | Controller:OutdoorAir | SPLIT TNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 700 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.34359 |
| 701 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.34359 |
| 702 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.34359 |
| 703 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.34359 |
| 704 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6408.41942 |
| 705 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 4293.64101 |
| 706 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 707 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 6408.41942 |
| 708 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 709 | Fan:OnOff | SPLIT TNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.34359 |
| 710 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.34359 |
| 711 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6408.41942 |
| 712 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80030 |
| 713 | Coil:Heating:DX:SingleSpeed | SPLIT TNE HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.34359 |
| 714 | Coil:Heating:DX:SingleSpeed | SPLIT TNE HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 6408.41942 |
| 715 | Coil:Heating:Electric | SPLIT TNE_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 6408.41942 |
| 716 | Controller:OutdoorAir | SPLIT TN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.31864 |
| 717 | Controller:OutdoorAir | SPLIT TN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 718 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.31864 |
| 719 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.31864 |
| 720 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.31864 |
| 721 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.31864 |
| 722 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5953.57890 |
| 723 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3988.89786 |
| 724 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 725 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5953.57890 |
| 726 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 727 | Fan:OnOff | SPLIT TN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.31864 |
| 728 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31864 |
| 729 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5953.57890 |
| 730 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80073 |
| 731 | Coil:Heating:DX:SingleSpeed | SPLIT TN1 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31864 |
| 732 | Coil:Heating:DX:SingleSpeed | SPLIT TN1 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5953.57890 |
| 733 | Coil:Heating:Electric | SPLIT TN1_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5953.57890 |
| 734 | Controller:OutdoorAir | SPLIT TN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.31742 |
| 735 | Controller:OutdoorAir | SPLIT TN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 736 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.31742 |
| 737 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.31742 |
| 738 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.31742 |
| 739 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.31742 |
| 740 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5934.89781 |
| 741 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3976.38153 |
| 742 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 743 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5934.89781 |
| 744 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 745 | Fan:OnOff | SPLIT TN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.31742 |
| 746 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31742 |
| 747 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5934.89781 |
| 748 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80051 |
| 749 | Coil:Heating:DX:SingleSpeed | SPLIT TN2 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31742 |
| 750 | Coil:Heating:DX:SingleSpeed | SPLIT TN2 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5934.89781 |
| 751 | Coil:Heating:Electric | SPLIT TN2_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5934.89781 |
| 752 | Controller:OutdoorAir | SPLIT TS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.31291 |
| 753 | Controller:OutdoorAir | SPLIT TS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 754 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.31291 |
| 755 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.31291 |
| 756 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.31291 |
| 757 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.31291 |
| 758 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5893.40756 |
| 759 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3948.58306 |
| 760 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 761 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5893.40756 |
| 762 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 763 | Fan:OnOff | SPLIT TS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.31291 |
| 764 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31291 |
| 765 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5893.40756 |
| 766 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80013 |
| 767 | Coil:Heating:DX:SingleSpeed | SPLIT TS1 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31291 |
| 768 | Coil:Heating:DX:SingleSpeed | SPLIT TS1 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5893.40756 |
| 769 | Coil:Heating:Electric | SPLIT TS1_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5893.40756 |
| 770 | Controller:OutdoorAir | SPLIT TS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.31168 |
| 771 | Controller:OutdoorAir | SPLIT TS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 772 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.31168 |
| 773 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.31168 |
| 774 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.31168 |
| 775 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.31168 |
| 776 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5874.93881 |
| 777 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3936.20900 |
| 778 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 779 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5874.93881 |
| 780 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 781 | Fan:OnOff | SPLIT TS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.31168 |
| 782 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31168 |
| 783 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5874.93881 |
| 784 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80088 |
| 785 | Coil:Heating:DX:SingleSpeed | SPLIT TS2 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31168 |
| 786 | Coil:Heating:DX:SingleSpeed | SPLIT TS2 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5874.93881 |
| 787 | Coil:Heating:Electric | SPLIT TS2_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5874.93881 |
| 788 | PlantLoop | SWHSYS1 | Maximum Loop Flow Rate [m3/s] | 1.13460E-004 |
| 789 | PlantLoop | SWHSYS1 | Plant Loop Volume [m3] | 1.36152E-002 |
| 790 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Flow Rate [m3/s] | 1.13460E-004 |
| 791 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Power Consumption [W] | 14.49330 |
| 792 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | Use Side Design Flow Rate [m3/s] | 1.13460E-004 |
| Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER User {Btu/W-h} | SEER Standard {Btu/W-h} | IEER {Btu/W-h} | |
| 1 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW HP COOLING COIL | 5635.4 | 3.14 | 10.72 | 11.16 | 10.56 | 10.57 |
| 2 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW HP COOLING COIL | 5652.0 | 3.14 | 10.71 | 11.14 | 10.54 | 10.55 |
| 3 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE HP COOLING COIL | 6652.3 | 3.14 | 10.71 | 11.14 | 10.54 | 10.55 |
| 4 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE HP COOLING COIL | 5378.1 | 3.15 | 10.73 | 11.17 | 10.57 | 10.59 |
| 5 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 HP COOLING COIL | 4861.9 | 3.16 | 10.77 | 11.20 | 10.60 | 10.64 |
| 6 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 HP COOLING COIL | 4856.3 | 3.16 | 10.77 | 11.20 | 10.60 | 10.64 |
| 7 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 HP COOLING COIL | 4878.0 | 3.16 | 10.79 | 11.23 | 10.63 | 10.68 |
| 8 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 HP COOLING COIL | 4918.1 | 3.16 | 10.79 | 11.23 | 10.62 | 10.67 |
| 9 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW HP COOLING COIL | 12301.6 | 3.14 | 10.70 | 11.14 | 10.53 | 10.54 |
| 10 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW HP COOLING COIL | 12351.3 | 3.13 | 10.69 | 11.12 | 10.52 | 10.53 |
| 11 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE HP COOLING COIL | 11641.6 | 3.15 | 10.73 | 11.17 | 10.57 | 10.59 |
| 12 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE HP COOLING COIL | 11673.8 | 3.14 | 10.72 | 11.15 | 10.55 | 10.57 |
| 13 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 HP COOLING COIL | 10538.2 | 3.15 | 10.75 | 11.18 | 10.58 | 10.61 |
| 14 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 HP COOLING COIL | 10525.5 | 3.15 | 10.75 | 11.18 | 10.58 | 10.61 |
| 15 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 HP COOLING COIL | 10552.3 | 3.16 | 10.77 | 11.21 | 10.60 | 10.64 |
| 16 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 HP COOLING COIL | 10539.8 | 3.16 | 10.77 | 11.21 | 10.60 | 10.64 |
| 17 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW HP COOLING COIL | 6563.9 | 3.13 | 10.69 | 11.12 | 10.52 | 10.52 |
| 18 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW HP COOLING COIL | 6629.1 | 3.13 | 10.68 | 11.11 | 10.51 | 10.51 |
| 19 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE HP COOLING COIL | 6078.3 | 3.14 | 10.72 | 11.16 | 10.55 | 10.57 |
| 20 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE HP COOLING COIL | 6138.7 | 3.14 | 10.71 | 11.14 | 10.54 | 10.55 |
| 21 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 HP COOLING COIL | 5703.4 | 3.14 | 10.71 | 11.15 | 10.54 | 10.56 |
| 22 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 HP COOLING COIL | 5685.7 | 3.14 | 10.71 | 11.15 | 10.54 | 10.56 |
| 23 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 HP COOLING COIL | 5647.7 | 3.14 | 10.73 | 11.16 | 10.56 | 10.58 |
| 24 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 HP COOLING COIL | 5630.2 | 3.14 | 10.73 | 11.16 | 10.56 | 10.58 |
| Component Type | Component Name | High Temperature Heating (net) Rating Capacity {W} | Low Temperature Heating (net) Rating Capacity {W} | HSPF {Btu/W-h} | Region Number | |
| 1 | Coil:Heating:DX:SingleSpeed | SPLIT GSW HEATING COIL | 6130.0 | 3399.5 | 8.16 | 4 |
| 2 | Coil:Heating:DX:SingleSpeed | SPLIT GNW HEATING COIL | 6151.8 | 3412.4 | 8.15 | 4 |
| 3 | Coil:Heating:DX:SingleSpeed | SPLIT OFFICE HEATING COIL | 7240.9 | 4016.5 | 8.12 | 4 |
| 4 | Coil:Heating:DX:SingleSpeed | SPLIT GNE HEATING COIL | 5847.5 | 3242.3 | 8.14 | 4 |
| 5 | Coil:Heating:DX:SingleSpeed | SPLIT GN1 HEATING COIL | 5279.2 | 2925.6 | 8.11 | 4 |
| 6 | Coil:Heating:DX:SingleSpeed | SPLIT GN2 HEATING COIL | 5273.1 | 2922.2 | 8.11 | 4 |
| 7 | Coil:Heating:DX:SingleSpeed | SPLIT GS1 HEATING COIL | 5290.5 | 2930.6 | 8.12 | 4 |
| 8 | Coil:Heating:DX:SingleSpeed | SPLIT GS2 HEATING COIL | 5334.8 | 2955.3 | 8.12 | 4 |
| 9 | Coil:Heating:DX:SingleSpeed | SPLIT MSW HEATING COIL | 13393.2 | 7430.0 | 8.10 | 4 |
| 10 | Coil:Heating:DX:SingleSpeed | SPLIT MNW HEATING COIL | 13454.1 | 7465.2 | 8.09 | 4 |
| 11 | Coil:Heating:DX:SingleSpeed | SPLIT MSE HEATING COIL | 12657.9 | 7018.5 | 8.18 | 4 |
| 12 | Coil:Heating:DX:SingleSpeed | SPLIT MNE HEATING COIL | 12701.2 | 7044.3 | 8.17 | 4 |
| 13 | Coil:Heating:DX:SingleSpeed | SPLIT MN1 HEATING COIL | 11452.7 | 6349.0 | 8.13 | 4 |
| 14 | Coil:Heating:DX:SingleSpeed | SPLIT MN2 HEATING COIL | 11438.5 | 6341.1 | 8.13 | 4 |
| 15 | Coil:Heating:DX:SingleSpeed | SPLIT MS1 HEATING COIL | 11455.7 | 6348.1 | 8.14 | 4 |
| 16 | Coil:Heating:DX:SingleSpeed | SPLIT MS2 HEATING COIL | 11441.8 | 6340.3 | 8.14 | 4 |
| 17 | Coil:Heating:DX:SingleSpeed | SPLIT TSW HEATING COIL | 7151.3 | 3968.2 | 8.11 | 4 |
| 18 | Coil:Heating:DX:SingleSpeed | SPLIT TNW HEATING COIL | 7225.4 | 4010.1 | 8.11 | 4 |
| 19 | Coil:Heating:DX:SingleSpeed | SPLIT TSE HEATING COIL | 6612.6 | 3667.3 | 8.10 | 4 |
| 20 | Coil:Heating:DX:SingleSpeed | SPLIT TNE HEATING COIL | 6681.9 | 3706.5 | 8.10 | 4 |
| 21 | Coil:Heating:DX:SingleSpeed | SPLIT TN1 HEATING COIL | 6207.2 | 3443.0 | 8.16 | 4 |
| 22 | Coil:Heating:DX:SingleSpeed | SPLIT TN2 HEATING COIL | 6187.6 | 3432.0 | 8.16 | 4 |
| 23 | Coil:Heating:DX:SingleSpeed | SPLIT TS1 HEATING COIL | 6142.5 | 3406.2 | 8.16 | 4 |
| 24 | Coil:Heating:DX:SingleSpeed | SPLIT TS2 HEATING COIL | 6123.1 | 3395.4 | 8.16 | 4 |
| Zone Name | # Surfaces | |
| 1 | G SW APARTMENT | 9 |
| 2 | G NW APARTMENT | 9 |
| 3 | OFFICE | 9 |
| 4 | G NE APARTMENT | 9 |
| 5 | G N1 APARTMENT | 8 |
| 6 | G N2 APARTMENT | 8 |
| 7 | G S1 APARTMENT | 8 |
| 8 | G S2 APARTMENT | 8 |
| 9 | M SW APARTMENT | 9 |
| 10 | M NW APARTMENT | 9 |
| 11 | M SE APARTMENT | 9 |
| 12 | M NE APARTMENT | 9 |
| 13 | M N1 APARTMENT | 8 |
| 14 | M N2 APARTMENT | 8 |
| 15 | M S1 APARTMENT | 8 |
| 16 | M S2 APARTMENT | 8 |
| 17 | T SW APARTMENT | 9 |
| 18 | T NW APARTMENT | 9 |
| 19 | T SE APARTMENT | 9 |
| 20 | T NE APARTMENT | 9 |
| 21 | T N1 APARTMENT | 8 |
| 22 | T N2 APARTMENT | 8 |
| 23 | T S1 APARTMENT | 8 |
| 24 | T S2 APARTMENT | 8 |
| 25 | T CORRIDOR | 13 |
| 26 | G CORRIDOR | 13 |
| 27 | M CORRIDOR | 13 |
| Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
| 1 | G SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 1.154 | 0.984 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 2 | GWINDOW1 S SWA | Window | G SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 3 | G WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 1.154 | 0.984 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 4 | GWINDOW1 W SWA | Window | G WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 5 | G NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 6 | G EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 7 | G GFLOOR SWA | Floor | CTF - ConductionTransferFunction | GGFLOORSWA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 8 | G CEILIN SWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 9 | G INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 10 | G NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 1.154 | 0.984 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 11 | GWINDOW1 N NWA | Window | G NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 12 | G WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 1.154 | 0.984 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 13 | GWINDOW1 W NWA | Window | G WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 14 | G SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 15 | G EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 16 | G GFLOOR NWA | Floor | CTF - ConductionTransferFunction | GGFLOORNWA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 17 | G CEILIN NWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 18 | G INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 19 | G SWALL SEA | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.154 | 0.984 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 20 | GWINDOW1 S SEA | Window | G SWALL SEA | Window5 Detailed Fenestration | NONRESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 21 | G EWALL SEA | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.154 | 0.984 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 22 | GWINDOW1 E SEA | Window | G EWALL SEA | Window5 Detailed Fenestration | NONRESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 23 | G NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 24 | iz-G EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 25 | G GFLOOR SEA | Floor | CTF - ConductionTransferFunction | GGFLOORSEA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 26 | G CEILIN SEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 27 | G INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 28 | G NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 1.154 | 0.984 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 29 | GWINDOW1 N NEA | Window | G NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 30 | G EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 1.154 | 0.984 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 31 | GWINDOW1 E NEA | Window | G EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 32 | G SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 33 | iz-G EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 34 | G GFLOOR NEA | Floor | CTF - ConductionTransferFunction | GGFLOORNEA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 35 | G CEILIN NEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 36 | G INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 37 | G NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 1.154 | 0.984 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 38 | GWINDOW1 N N1A | Window | G NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 39 | G SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 40 | G EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 41 | iz-G EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 42 | G GFLOOR N1A | Floor | CTF - ConductionTransferFunction | GGFLOORN1A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 43 | G CEILIN N1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 44 | G INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 45 | G NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 1.154 | 0.984 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 46 | GWINDOW1 N N2A | Window | G NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 47 | G SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 48 | G EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 49 | iz-G EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 50 | G GFLOOR N2A | Floor | CTF - ConductionTransferFunction | GGFLOORN2A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 51 | G CEILIN N2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 52 | G INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 53 | G SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 1.154 | 0.984 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 54 | GWINDOW1 S S1A | Window | G SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 55 | G NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 56 | G EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 57 | iz-G EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 58 | G GFLOOR S1A | Floor | CTF - ConductionTransferFunction | GGFLOORS1A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 59 | G CEILIN S1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 60 | G INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 61 | G SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 1.154 | 0.984 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 62 | GWINDOW1 S S2A | Window | G SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 63 | G NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 64 | G EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 65 | iz-G EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 66 | G GFLOOR S2A | Floor | CTF - ConductionTransferFunction | GGFLOORS2A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 67 | G CEILIN S2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 68 | G INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 69 | M WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 70 | MWINDOW1 W SWA | Window | M WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 71 | M SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 72 | MWINDOW1 S SWA | Window | M SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 73 | M NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 74 | M EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 3.05 | 7.62 | 0.00 | iz-M EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 75 | M GFLOOR SWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 76 | M CEILIN SWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 77 | M INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 78 | M NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 79 | MWINDOW1 N NWA | Window | M NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 80 | M WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 81 | MWINDOW1 W NWA | Window | M WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 82 | M SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 83 | M EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 84 | M GFLOOR NWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 85 | M CEILIN NWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 86 | M INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 87 | M EWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 88 | MWINDOW1 E SEA | Window | M EWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 89 | M SWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 90 | MWINDOW1 S SEA | Window | M SWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 91 | M NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 92 | iz-M EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 93 | M GFLOOR SEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 94 | M CEILIN SEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 95 | M INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 96 | M NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 97 | MWINDOW1 N NEA | Window | M NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 98 | M EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 99 | MWINDOW1 E NEA | Window | M EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 100 | M SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 101 | iz-M EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 102 | M GFLOOR NEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 103 | M CEILIN NEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 104 | M INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 105 | M NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 106 | MWINDOW1 N N1A | Window | M NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 107 | M SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 108 | M EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 109 | iz-M EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 110 | M GFLOOR N1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 111 | M CEILIN N1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 112 | M INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 113 | M NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 114 | MWINDOW1 N N2A | Window | M NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 115 | M SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 116 | M EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 117 | iz-M EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 118 | M GFLOOR N2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 119 | M CEILIN N2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 120 | M INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 121 | M SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 122 | MWINDOW1 S S1A | Window | M SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 123 | M NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 124 | M EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 125 | iz-M EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 3.05 | 7.62 | 0.00 | M EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 126 | M GFLOOR S1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 127 | M CEILIN S1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 128 | M INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 129 | M SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 130 | MWINDOW1 S S2A | Window | M SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 131 | M NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 132 | M EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 133 | iz-M EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 134 | M GFLOOR S2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 135 | M CEILIN S2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 136 | M INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 137 | T WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 138 | TWINDOW1 W SWA | Window | T WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 139 | T SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 140 | TWINDOW1 S SWA | Window | T SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 141 | T NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 142 | T EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 143 | T GFLOOR SWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 144 | T ROOF SWA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.186 | 0.180 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 145 | T INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 146 | T NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 147 | TWINDOW1 N NWA | Window | T NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 148 | T WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 149 | TWINDOW1 W NWA | Window | T WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 150 | T SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 151 | T EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 152 | T GFLOOR NWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 153 | T ROOF NWA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.186 | 0.180 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 154 | T INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 155 | T EWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 156 | TWINDOW1 E SEA | Window | T EWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 157 | T SWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 158 | TWINDOW1 S SEA | Window | T SWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 159 | T NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 160 | iz-T EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 161 | T GFLOOR SEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 162 | T ROOF SEA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.186 | 0.180 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 163 | T INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 164 | T NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 165 | TWINDOW1 N NEA | Window | T NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 166 | T EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 167 | TWINDOW1 E NEA | Window | T EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 168 | T SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 169 | iz-T EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 170 | T GFLOOR NEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 171 | T ROOF NEA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.186 | 0.180 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 172 | T INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 173 | T NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 174 | TWINDOW1 N N1A | Window | T NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 175 | T SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 176 | T EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 177 | iz-T EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 178 | T GFLOOR N1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 179 | T ROOF N1A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.186 | 0.180 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 180 | T INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 181 | T NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 182 | TWINDOW1 N N2A | Window | T NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 183 | T SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 184 | T EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 185 | iz-T EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 186 | T GFLOOR N2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 187 | T ROOF N2A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.186 | 0.180 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 188 | T INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 189 | T SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 190 | TWINDOW1 S S1A | Window | T SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 191 | T NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 192 | T EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 193 | iz-T EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 194 | T GFLOOR S1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 195 | T ROOF S1A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.186 | 0.180 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 196 | T INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 197 | T SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 198 | TWINDOW1 S S2A | Window | T SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 199 | T NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 200 | T EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 201 | iz-T EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 202 | T GFLOOR S2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 203 | T ROOF S2A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.186 | 0.180 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 204 | T INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 205 | T WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.430 | 1.178 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 206 | T EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.430 | 1.178 | 3.99 | 5.11 | 3.99 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 207 | TWINDOW14 | Window | T EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 1.11 | 1.11 | 1.11 | 90.00 | 90.00 | 0.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 208 | iz-T NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 209 | iz-T NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 210 | iz-T NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 211 | iz-T NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 212 | iz-T SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 213 | iz-T SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 214 | iz-T SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 215 | iz-T SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 216 | T FLOOR C | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | T FLOOR C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 217 | T ROOF C | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 218 | G WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.154 | 0.984 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 219 | G EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.154 | 0.984 | 1.79 | 5.11 | 1.79 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 220 | ENTRANCE DOOR | Window | G EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 3.32 | 3.32 | 3.32 | 90.00 | 90.00 | 1.57 | 2.11 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 221 | iz-G NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 222 | iz-G NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 223 | iz-G NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 224 | iz-G NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 225 | iz-G SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 226 | iz-G SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 227 | iz-G SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 228 | iz-G SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 229 | G FLOOR C | Floor | CTF - ConductionTransferFunction | GFLOORC_FFACTOR | 5.502E-002 | 5.429E-002 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 230 | G CEILING C | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | G CEILING C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 231 | M WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.171 | 0.996 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 232 | M EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.171 | 0.996 | 3.99 | 5.11 | 3.99 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 233 | MWINDOW14 | Window | M EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.53_SHGC_0.215 | N/A | 3.013 | No | 1.11 | 1.11 | 1.11 | 90.00 | 90.00 | 0.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 234 | iz-M NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 235 | iz-M NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 236 | iz-M NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 237 | iz-M NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 238 | iz-M SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 239 | iz-M SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 240 | iz-M SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 241 | iz-M SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 242 | M FLOOR C | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | M FLOOR C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 243 | M CEILING C | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | M CEILING C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
| Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
| 1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | Yes | Yes | Yes | Clark and Allen |
| Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
| 1 | NEW YEAR'S DAY | Holiday | InputFile | 01/02 | 1Environment:Special Days |
| Daylight Saving Indicator | Source | Start Date | End Date | |
| 1 | Yes | InputFile | 03/12 | 11/05 |
| Style | Unit Conversion | |
| 1 | Commaandhtml | commaandhtml |
| Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
| 1 | G SW APARTMENT | RunPeriod: RUNPERIOD 1 | 2.8036183190E-002 | 0.1606223923 | Pass | Pass | 1.9464423080 | 19.9533913267 | Pass | Pass |
| 2 | G NW APARTMENT | RunPeriod: RUNPERIOD 1 | 2.7697217628E-002 | 0.1592211331 | Pass | Pass | 1.7075899298 | 16.7118594195 | Pass | Pass |
| 3 | OFFICE | RunPeriod: RUNPERIOD 1 | 1.0247458501E-002 | 2.8944338474E-002 | Pass | Pass | 0.2369627153 | 1.0943108026 | Pass | Pass |
| 4 | G NE APARTMENT | RunPeriod: RUNPERIOD 1 | 2.7784383617E-002 | 0.1594326383 | Pass | Pass | 1.8401398348 | 18.0122220396 | Pass | Pass |
| 5 | G N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.6667897763E-002 | 0.1519839144 | Pass | Pass | 2.0670290597 | 14.8059432578 | Pass | Pass |
| 6 | G N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.6683835898E-002 | 0.1520458613 | Pass | Pass | 2.6467821108 | 17.5639479097 | Pass | Pass |
| 7 | G S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.7792921682E-002 | 0.1578310686 | Pass | Pass | 1.8678140003 | 17.3945527789 | Pass | Pass |
| 8 | G S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 3.0724124006E-002 | 0.1636243612 | Pass | Pass | 4.4117811120 | 51.1637426743 | Pass | Pass |
| 9 | M SW APARTMENT | RunPeriod: RUNPERIOD 1 | 2.4785857488E-002 | 0.1441856746 | Pass | Pass | 0.9519440923 | 9.7977415636 | Pass | Pass |
| 10 | M NW APARTMENT | RunPeriod: RUNPERIOD 1 | 2.3342894882E-002 | 0.1386522974 | Pass | Pass | 0.8284799149 | 8.6133414275 | Pass | Pass |
| 11 | M SE APARTMENT | RunPeriod: RUNPERIOD 1 | 2.5512484307E-002 | 0.1463572267 | Pass | Pass | 1.0549223708 | 10.4278692991 | Pass | Pass |
| 12 | M NE APARTMENT | RunPeriod: RUNPERIOD 1 | 2.4074494233E-002 | 0.1397739225 | Pass | Pass | 0.8914933593 | 9.1203674571 | Pass | Pass |
| 13 | M N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.2554778172E-002 | 0.1308912162 | Pass | Pass | 0.8599008876 | 8.1260567598 | Pass | Pass |
| 14 | M N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.2570127986E-002 | 0.1309362950 | Pass | Pass | 0.8588098618 | 8.1275662951 | Pass | Pass |
| 15 | M S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.4058857010E-002 | 0.1378118763 | Pass | Pass | 0.8973257985 | 9.1148726865 | Pass | Pass |
| 16 | M S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.4073943416E-002 | 0.1378560855 | Pass | Pass | 0.8977838592 | 9.1211272003 | Pass | Pass |
| 17 | T SW APARTMENT | RunPeriod: RUNPERIOD 1 | 2.7784223450E-002 | 0.1574763604 | Pass | Pass | 0.8164732965 | 8.2960289737 | Pass | Pass |
| 18 | T NW APARTMENT | RunPeriod: RUNPERIOD 1 | 2.7721026613E-002 | 0.1564157434 | Pass | Pass | 0.9247850740 | 7.8534719022 | Pass | Pass |
| 19 | T SE APARTMENT | RunPeriod: RUNPERIOD 1 | 2.8043431308E-002 | 0.1572238015 | Pass | Pass | 0.8832711917 | 8.9656799143 | Pass | Pass |
| 20 | T NE APARTMENT | RunPeriod: RUNPERIOD 1 | 2.7783229520E-002 | 0.1559105980 | Pass | Pass | 0.9015589041 | 8.2542065835 | Pass | Pass |
| 21 | T N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.7629493736E-002 | 0.1538288360 | Pass | Pass | 1.0055703044 | 8.1689350040 | Pass | Pass |
| 22 | T N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.7651987601E-002 | 0.1538960347 | Pass | Pass | 1.0057318424 | 8.1797167135 | Pass | Pass |
| 23 | T S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.7784154166E-002 | 0.1553132085 | Pass | Pass | 0.9349937487 | 8.5370072176 | Pass | Pass |
| 24 | T S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.7784152042E-002 | 0.1553053336 | Pass | Pass | 0.9292027781 | 8.5295306908 | Pass | Pass |
| 25 | T CORRIDOR | RunPeriod: RUNPERIOD 1 | 1.0700932777E-002 | 7.7951588671E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 26 | G CORRIDOR | RunPeriod: RUNPERIOD 1 | 4.6400901625E-002 | 0.1154156714 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 27 | M CORRIDOR | RunPeriod: RUNPERIOD 1 | 4.1125770650E-003 | 4.8035258456E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
Heat Emission by Components| Envelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
| Heat Emissions [GJ] | 1549.17 | -47.6 | 0.00 | -12.0 | 2228.99 | 3718.56 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
SizingPeriod:DesignDay| Maximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
| HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 20.10 | 0.00 | 20.10 | Wetbulb [C] | 1.80 | 0.00 |
| HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 35.20 | 8.50 | 25.80 | Wetbulb [C] | 4.10 | 160.00 |
| Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
| Jan | 57.00 | 12 | |||
| Feb | 0.00 | 0 | |||
| Mar | 153.60 | 31 | |||
| Apr | 87.00 | 59 | |||
| May | 227.22 | 128 | |||
| Jun | 144.58 | 109 | |||
| Jul | 42.40 | 24 | |||
| Aug | 164.90 | 163 | |||
| Sep | 119.60 | 50 | |||
| Oct | 365.70 | 188 | |||
| Nov | 70.90 | 67 | |||
| Dec | 0.00 | 0 |
| Value | |
| None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
Opaque Exterior| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| G SWALL SWA | RES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G WWALL SWA | RES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| G GFLOOR SWA | GGFLOORSWA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL NWA | RES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G WWALL NWA | RES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| G GFLOOR NWA | GGFLOORNWA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL SEA | NONRES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G EWALL SEA | NONRES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| G GFLOOR SEA | GGFLOORSEA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL NEA | RES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G EWALL NEA | RES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| G GFLOOR NEA | GGFLOORNEA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL N1A | RES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G GFLOOR N1A | GGFLOORN1A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL N2A | RES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G GFLOOR N2A | GGFLOORN2A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL S1A | RES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G GFLOOR S1A | GGFLOORS1A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL S2A | RES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G GFLOOR S2A | GGFLOORS2A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| M WWALL SWA | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 46.45 | 37.16 | 270.00 | 90.00 | W |
| M SWALL SWA | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M NWALL NWA | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M WWALL NWA | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 46.45 | 37.16 | 270.00 | 90.00 | W |
| M EWALL SEA | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 46.45 | 37.16 | 90.00 | 90.00 | E |
| M SWALL SEA | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M NWALL NEA | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M EWALL NEA | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 46.45 | 37.16 | 90.00 | 90.00 | E |
| M NWALL N1A | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M NWALL N2A | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M SWALL S1A | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M SWALL S2A | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| T WWALL SWA | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| T SWALL SWA | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF SWA | RES_ROOF | 0.55 | 0.182 | 0.186 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL NWA | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T WWALL NWA | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| T ROOF NWA | RES_ROOF | 0.55 | 0.182 | 0.186 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T EWALL SEA | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| T SWALL SEA | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF SEA | RES_ROOF | 0.55 | 0.182 | 0.186 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL NEA | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T EWALL NEA | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| T ROOF NEA | RES_ROOF | 0.55 | 0.182 | 0.186 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL N1A | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T ROOF N1A | RES_ROOF | 0.55 | 0.182 | 0.186 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL N2A | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T ROOF N2A | RES_ROOF | 0.55 | 0.182 | 0.186 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T SWALL S1A | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF S1A | RES_ROOF | 0.55 | 0.182 | 0.186 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T SWALL S2A | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF S2A | RES_ROOF | 0.55 | 0.182 | 0.186 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T WWALL C | NONRES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 5.11 | 5.11 | 270.00 | 90.00 | W |
| T EWALL C | NONRES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 5.11 | 3.99 | 90.00 | 90.00 | E |
| T ROOF C | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 77.66 | 77.66 | 180.00 | 0.00 | |
| G WWALL C | NONRES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 5.11 | 5.11 | 270.00 | 90.00 | W |
| G EWALL C | NONRES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 5.11 | 1.79 | 90.00 | 90.00 | E |
| G FLOOR C | GFLOORC_FFACTOR | 1.00 | 0.055 | 0.055 | 77.66 | 77.66 | 90.00 | 180.00 | |
| M WWALL C | NONRES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 10.22 | 10.22 | 270.00 | 90.00 | W |
| M EWALL C | NONRES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 10.22 | 7.99 | 90.00 | 90.00 | E |
| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| G NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| G CEILIN SWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| G CEILIN NWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN SEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN NEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN N1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN N2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN S1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN S2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| M NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| M GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN SWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| M GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN NWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN SEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN NEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN N1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN N2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN S1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN S2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| T NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| T GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| T GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| iz-T NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T FLOOR C | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 77.66 | 77.66 | 90.00 | 180.00 | |
| iz-G NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G CEILING C | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 77.66 | 77.66 | 180.00 | 0.00 | |
| iz-M NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M FLOOR C | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 155.32 | 155.32 | 90.00 | 180.00 | |
| M CEILING C | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 155.32 | 155.32 | 180.00 | 0.00 | |
| G INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| M INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| T INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N |
| Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| GWINDOW1 S SWA | RESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.216 | 0.237 | No | G SWALL SWA | 180.00 | 90.00 | S | |||||||
| GWINDOW1 W SWA | RESWINDOW_U_0.53_SHGC_0.215 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.013 | 0.216 | 0.237 | No | G WWALL SWA | 270.00 | 90.00 | W | |||||||
| GWINDOW1 N NWA | RESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.216 | 0.237 | No | G NWALL NWA | 0.00 | 90.00 | N | |||||||
| GWINDOW1 W NWA | RESWINDOW_U_0.53_SHGC_0.215 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.013 | 0.216 | 0.237 | No | G WWALL NWA | 270.00 | 90.00 | W | |||||||
| GWINDOW1 S SEA | NONRESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.216 | 0.237 | No | G SWALL SEA | 180.00 | 90.00 | S | |||||||
| GWINDOW1 E SEA | NONRESWINDOW_U_0.53_SHGC_0.215 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.013 | 0.216 | 0.237 | No | G EWALL SEA | 90.00 | 90.00 | E | |||||||
| GWINDOW1 N NEA | RESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.216 | 0.237 | No | G NWALL NEA | 0.00 | 90.00 | N | |||||||
| GWINDOW1 E NEA | RESWINDOW_U_0.53_SHGC_0.215 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.013 | 0.216 | 0.237 | No | G EWALL NEA | 90.00 | 90.00 | E | |||||||
| GWINDOW1 N N1A | RESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.216 | 0.237 | No | G NWALL N1A | 0.00 | 90.00 | N | |||||||
| GWINDOW1 N N2A | RESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.216 | 0.237 | No | G NWALL N2A | 0.00 | 90.00 | N | |||||||
| GWINDOW1 S S1A | RESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.216 | 0.237 | No | G SWALL S1A | 180.00 | 90.00 | S | |||||||
| GWINDOW1 S S2A | RESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.216 | 0.237 | No | G SWALL S2A | 180.00 | 90.00 | S | |||||||
| MWINDOW1 W SWA | RESWINDOW_U_0.53_SHGC_0.215 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 3.013 | 0.216 | 0.237 | No | M WWALL SWA | 270.00 | 90.00 | W | |||||||
| MWINDOW1 S SWA | RESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.013 | 0.216 | 0.237 | No | M SWALL SWA | 180.00 | 90.00 | S | |||||||
| MWINDOW1 N NWA | RESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.013 | 0.216 | 0.237 | No | M NWALL NWA | 0.00 | 90.00 | N | |||||||
| MWINDOW1 W NWA | RESWINDOW_U_0.53_SHGC_0.215 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 3.013 | 0.216 | 0.237 | No | M WWALL NWA | 270.00 | 90.00 | W | |||||||
| MWINDOW1 E SEA | RESWINDOW_U_0.53_SHGC_0.215 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 3.013 | 0.216 | 0.237 | No | M EWALL SEA | 90.00 | 90.00 | E | |||||||
| MWINDOW1 S SEA | RESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.013 | 0.216 | 0.237 | No | M SWALL SEA | 180.00 | 90.00 | S | |||||||
| MWINDOW1 N NEA | RESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.013 | 0.216 | 0.237 | No | M NWALL NEA | 0.00 | 90.00 | N | |||||||
| MWINDOW1 E NEA | RESWINDOW_U_0.53_SHGC_0.215 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 3.013 | 0.216 | 0.237 | No | M EWALL NEA | 90.00 | 90.00 | E | |||||||
| MWINDOW1 N N1A | RESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.013 | 0.216 | 0.237 | No | M NWALL N1A | 0.00 | 90.00 | N | |||||||
| MWINDOW1 N N2A | RESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.013 | 0.216 | 0.237 | No | M NWALL N2A | 0.00 | 90.00 | N | |||||||
| MWINDOW1 S S1A | RESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.013 | 0.216 | 0.237 | No | M SWALL S1A | 180.00 | 90.00 | S | |||||||
| MWINDOW1 S S2A | RESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.013 | 0.216 | 0.237 | No | M SWALL S2A | 180.00 | 90.00 | S | |||||||
| TWINDOW1 W SWA | RESWINDOW_U_0.53_SHGC_0.215 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.013 | 0.216 | 0.237 | No | T WWALL SWA | 270.00 | 90.00 | W | |||||||
| TWINDOW1 S SWA | RESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.216 | 0.237 | No | T SWALL SWA | 180.00 | 90.00 | S | |||||||
| TWINDOW1 N NWA | RESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.216 | 0.237 | No | T NWALL NWA | 0.00 | 90.00 | N | |||||||
| TWINDOW1 W NWA | RESWINDOW_U_0.53_SHGC_0.215 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.013 | 0.216 | 0.237 | No | T WWALL NWA | 270.00 | 90.00 | W | |||||||
| TWINDOW1 E SEA | RESWINDOW_U_0.53_SHGC_0.215 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.013 | 0.216 | 0.237 | No | T EWALL SEA | 90.00 | 90.00 | E | |||||||
| TWINDOW1 S SEA | RESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.216 | 0.237 | No | T SWALL SEA | 180.00 | 90.00 | S | |||||||
| TWINDOW1 N NEA | RESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.216 | 0.237 | No | T NWALL NEA | 0.00 | 90.00 | N | |||||||
| TWINDOW1 E NEA | RESWINDOW_U_0.53_SHGC_0.215 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.013 | 0.216 | 0.237 | No | T EWALL NEA | 90.00 | 90.00 | E | |||||||
| TWINDOW1 N N1A | RESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.216 | 0.237 | No | T NWALL N1A | 0.00 | 90.00 | N | |||||||
| TWINDOW1 N N2A | RESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.216 | 0.237 | No | T NWALL N2A | 0.00 | 90.00 | N | |||||||
| TWINDOW1 S S1A | RESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.216 | 0.237 | No | T SWALL S1A | 180.00 | 90.00 | S | |||||||
| TWINDOW1 S S2A | RESWINDOW_U_0.53_SHGC_0.215 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.216 | 0.237 | No | T SWALL S2A | 180.00 | 90.00 | S | |||||||
| TWINDOW14 | NONRESWINDOW_U_0.53_SHGC_0.215 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 3.013 | 0.216 | 0.237 | No | T EWALL C | 90.00 | 90.00 | E | |||||||
| ENTRANCE DOOR | NONRESWINDOW_U_0.53_SHGC_0.215 | 3.32 | 0.00 | 0.00 | 3.32 | 3.32 | 3.013 | 0.216 | 0.237 | No | G EWALL C | 90.00 | 90.00 | E | |||||||
| MWINDOW14 | NONRESWINDOW_U_0.53_SHGC_0.215 | 1.11 | 0.00 | 0.00 | 1.11 | 2.23 | 3.013 | 0.216 | 0.237 | No | M EWALL C | 90.00 | 90.00 | E | |||||||
| Total or Average | 306.92 | 3.013 | 0.216 | 0.237 | |||||||||||||||||
| North Total or Average | 112.97 | 3.013 | 0.216 | 0.237 | |||||||||||||||||
| Non-North Total or Average | 193.95 | 3.013 | 0.216 | 0.237 |
| Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
| None |
| Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
| Total or Average | 0.00 | - | - | - |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
Sunlit Fraction| March 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
| GWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| GWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| GWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| GWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| GWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| MWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| MWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| TWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| TWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| TWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| TWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| Name | Type | Shaded Construction | Control | Glare Control | |
| None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
Interior Lighting| Zone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
| LIGHTING_HARDWIRED_GSW | G SW APARTMENT | G SW APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_GNW | G NW APARTMENT | G NW APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_OFFICE | OFFICE | OFFICE | GENERAL | 7.4895 | 88.25 | 660.94 | LightsWired | LTG_SCH_OFFICE | 46.69 | 168.00 | 45.77 | 0.0000 | Y | 5.68 |
| LIGHTING_HARDWIRED_GNE | G NE APARTMENT | G NE APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_GN1 | G N1 APARTMENT | G N1 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_GN2 | G N2 APARTMENT | G N2 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_GS1 | G S1 APARTMENT | G S1 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_GS2 | G S2 APARTMENT | G S2 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_MSW | M SW APARTMENT | M SW APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_MNW | M NW APARTMENT | M NW APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_MSE | M SE APARTMENT | M SE APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_MNE | M NE APARTMENT | M NE APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_MN1 | M N1 APARTMENT | M N1 APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_MN2 | M N2 APARTMENT | M N2 APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_MS1 | M S1 APARTMENT | M S1 APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_MS2 | M S2 APARTMENT | M S2 APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_TSW | T SW APARTMENT | T SW APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_TNW | T NW APARTMENT | T NW APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_TSE | T SE APARTMENT | T SE APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_TNE | T NE APARTMENT | T NE APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_TN1 | T N1 APARTMENT | T N1 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_TN2 | T N2 APARTMENT | T N2 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_TS1 | T S1 APARTMENT | T S1 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_TS2 | T S2 APARTMENT | T S2 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_GC | G CORRIDOR | G CORRIDOR | GENERAL | 5.2871 | 77.66 | 410.59 | LightsWired | LTG_SCH_CORRIDOR | 126.00 | 168.00 | 126.00 | 0.0000 | N | 9.71 |
| LIGHTING_HARDWIRED_MC | M CORRIDOR | M CORRIDOR | GENERAL | 5.2871 | 155.32 | 821.19 | LightsWired | LTG_SCH_CORRIDOR | 126.00 | 168.00 | 126.00 | 0.0000 | N | 19.42 |
| LIGHTING_HARDWIRED_TC | T CORRIDOR | T CORRIDOR | GENERAL | 5.2871 | 77.66 | 410.59 | LightsWired | LTG_SCH_CORRIDOR | 126.00 | 168.00 | 126.00 | 0.0000 | N | 9.71 |
| LIGHTING_PLUGIN_GSW | G SW APARTMENT | G SW APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_GNW | G NW APARTMENT | G NW APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_GNE | G NE APARTMENT | G NE APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_GN1 | G N1 APARTMENT | G N1 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_GN2 | G N2 APARTMENT | G N2 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_GS1 | G S1 APARTMENT | G S1 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_GS2 | G S2 APARTMENT | G S2 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_MSW | M SW APARTMENT | M SW APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_MNW | M NW APARTMENT | M NW APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_MSE | M SE APARTMENT | M SE APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_MNE | M NE APARTMENT | M NE APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_MN1 | M N1 APARTMENT | M N1 APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_MN2 | M N2 APARTMENT | M N2 APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_MS1 | M S1 APARTMENT | M S1 APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_MS2 | M S2 APARTMENT | M S2 APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_TSW | T SW APARTMENT | T SW APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_TNW | T NW APARTMENT | T NW APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_TSE | T SE APARTMENT | T SE APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_TNE | T NE APARTMENT | T NE APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_TN1 | T N1 APARTMENT | T N1 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_TN2 | T N2 APARTMENT | T N2 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_TS1 | T S1 APARTMENT | T S1 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_TS2 | T S2 APARTMENT | T S2 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| Interior Lighting Total | 2.9507 | 5870.34 | 17321.34 | 55.94 |
| Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
| None |
| Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
| FACADE LIGHTING | 2101.03 | AstronomicalClock | - | 83.83 | 83.83 | 33.06 | |
| Exterior Lighting Total | 2101.03 | 33.06 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
Central Plant| Type | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
| None |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
| SPLIT GSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5881.00 | 4708.94 | 1172.06 | 0.80 | 3.82 | |||
| SPLIT GNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5900.19 | 4720.70 | 1179.50 | 0.80 | 3.82 | |||
| SPLIT OFFICE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6944.57 | 5557.36 | 1387.20 | 0.80 | 3.82 | |||
| SPLIT GNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5611.16 | 4483.14 | 1128.01 | 0.80 | 3.82 | |||
| SPLIT GN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5069.03 | 4018.30 | 1050.72 | 0.79 | 3.82 | |||
| SPLIT GN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5063.22 | 4013.21 | 1050.01 | 0.79 | 3.82 | |||
| SPLIT GS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5082.78 | 3995.55 | 1087.23 | 0.79 | 3.82 | |||
| SPLIT GS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5124.92 | 4032.02 | 1092.91 | 0.79 | 3.82 | |||
| SPLIT MSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 12843.65 | 10277.57 | 2566.09 | 0.80 | 3.82 | |||
| SPLIT MNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 12898.91 | 10321.42 | 2577.49 | 0.80 | 3.82 | |||
| SPLIT MSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 12146.23 | 9717.13 | 2429.11 | 0.80 | 3.82 | |||
| SPLIT MNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 12183.91 | 9754.36 | 2429.55 | 0.80 | 3.82 | |||
| SPLIT MN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10992.24 | 8762.08 | 2230.16 | 0.80 | 3.82 | |||
| SPLIT MN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10978.77 | 8750.25 | 2228.51 | 0.80 | 3.82 | |||
| SPLIT MS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 11000.75 | 8700.79 | 2299.96 | 0.79 | 3.82 | |||
| SPLIT MS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10987.57 | 8689.10 | 2298.47 | 0.79 | 3.82 | |||
| SPLIT TSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6855.57 | 5490.60 | 1364.98 | 0.80 | 3.82 | |||
| SPLIT TNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6925.23 | 5544.26 | 1380.96 | 0.80 | 3.82 | |||
| SPLIT TSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6343.61 | 5076.01 | 1267.60 | 0.80 | 3.82 | |||
| SPLIT TNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6408.42 | 5128.67 | 1279.75 | 0.80 | 3.82 | |||
| SPLIT TN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5953.58 | 4767.22 | 1186.36 | 0.80 | 3.82 | |||
| SPLIT TN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5934.90 | 4750.92 | 1183.98 | 0.80 | 3.82 | |||
| SPLIT TS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5893.41 | 4715.51 | 1177.90 | 0.80 | 3.82 | |||
| SPLIT TS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5874.94 | 4705.13 | 1169.81 | 0.80 | 3.82 |
| DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
| SPLIT GSW HP COOLING COIL | 5635.4 | 3.14 | 10.72 | 11.16 | 10.56 | 10.57 | |
| SPLIT GNW HP COOLING COIL | 5652.0 | 3.14 | 10.71 | 11.14 | 10.54 | 10.55 | |
| SPLIT OFFICE HP COOLING COIL | 6652.3 | 3.14 | 10.71 | 11.14 | 10.54 | 10.55 | |
| SPLIT GNE HP COOLING COIL | 5378.1 | 3.15 | 10.73 | 11.17 | 10.57 | 10.59 | |
| SPLIT GN1 HP COOLING COIL | 4861.9 | 3.16 | 10.77 | 11.20 | 10.60 | 10.64 | |
| SPLIT GN2 HP COOLING COIL | 4856.3 | 3.16 | 10.77 | 11.20 | 10.60 | 10.64 | |
| SPLIT GS1 HP COOLING COIL | 4878.0 | 3.16 | 10.79 | 11.23 | 10.63 | 10.68 | |
| SPLIT GS2 HP COOLING COIL | 4918.1 | 3.16 | 10.79 | 11.23 | 10.62 | 10.67 | |
| SPLIT MSW HP COOLING COIL | 12301.6 | 3.14 | 10.70 | 11.14 | 10.53 | 10.54 | |
| SPLIT MNW HP COOLING COIL | 12351.3 | 3.13 | 10.69 | 11.12 | 10.52 | 10.53 | |
| SPLIT MSE HP COOLING COIL | 11641.6 | 3.15 | 10.73 | 11.17 | 10.57 | 10.59 | |
| SPLIT MNE HP COOLING COIL | 11673.8 | 3.14 | 10.72 | 11.15 | 10.55 | 10.57 | |
| SPLIT MN1 HP COOLING COIL | 10538.2 | 3.15 | 10.75 | 11.18 | 10.58 | 10.61 | |
| SPLIT MN2 HP COOLING COIL | 10525.5 | 3.15 | 10.75 | 11.18 | 10.58 | 10.61 | |
| SPLIT MS1 HP COOLING COIL | 10552.3 | 3.16 | 10.77 | 11.21 | 10.60 | 10.64 | |
| SPLIT MS2 HP COOLING COIL | 10539.8 | 3.16 | 10.77 | 11.21 | 10.60 | 10.64 | |
| SPLIT TSW HP COOLING COIL | 6563.9 | 3.13 | 10.69 | 11.12 | 10.52 | 10.52 | |
| SPLIT TNW HP COOLING COIL | 6629.1 | 3.13 | 10.68 | 11.11 | 10.51 | 10.51 | |
| SPLIT TSE HP COOLING COIL | 6078.3 | 3.14 | 10.72 | 11.16 | 10.55 | 10.57 | |
| SPLIT TNE HP COOLING COIL | 6138.7 | 3.14 | 10.71 | 11.14 | 10.54 | 10.55 | |
| SPLIT TN1 HP COOLING COIL | 5703.4 | 3.14 | 10.71 | 11.15 | 10.54 | 10.56 | |
| SPLIT TN2 HP COOLING COIL | 5685.7 | 3.14 | 10.71 | 11.15 | 10.54 | 10.56 | |
| SPLIT TS1 HP COOLING COIL | 5647.7 | 3.14 | 10.73 | 11.16 | 10.56 | 10.58 | |
| SPLIT TS2 HP COOLING COIL | 5630.2 | 3.14 | 10.73 | 11.16 | 10.56 | 10.58 |
| DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
| SPLIT GSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT OFFICE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed |
| DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
| SPLIT GSW HEATING COIL | Coil:Heating:DX:SingleSpeed | 6130.0 | 3399.5 | 8.16 | 4 |
| SPLIT GNW HEATING COIL | Coil:Heating:DX:SingleSpeed | 6151.8 | 3412.4 | 8.15 | 4 |
| SPLIT OFFICE HEATING COIL | Coil:Heating:DX:SingleSpeed | 7240.9 | 4016.5 | 8.12 | 4 |
| SPLIT GNE HEATING COIL | Coil:Heating:DX:SingleSpeed | 5847.5 | 3242.3 | 8.14 | 4 |
| SPLIT GN1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5279.2 | 2925.6 | 8.11 | 4 |
| SPLIT GN2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5273.1 | 2922.2 | 8.11 | 4 |
| SPLIT GS1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5290.5 | 2930.6 | 8.12 | 4 |
| SPLIT GS2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5334.8 | 2955.3 | 8.12 | 4 |
| SPLIT MSW HEATING COIL | Coil:Heating:DX:SingleSpeed | 13393.2 | 7430.0 | 8.10 | 4 |
| SPLIT MNW HEATING COIL | Coil:Heating:DX:SingleSpeed | 13454.1 | 7465.2 | 8.09 | 4 |
| SPLIT MSE HEATING COIL | Coil:Heating:DX:SingleSpeed | 12657.9 | 7018.5 | 8.18 | 4 |
| SPLIT MNE HEATING COIL | Coil:Heating:DX:SingleSpeed | 12701.2 | 7044.3 | 8.17 | 4 |
| SPLIT MN1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 11452.7 | 6349.0 | 8.13 | 4 |
| SPLIT MN2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 11438.5 | 6341.1 | 8.13 | 4 |
| SPLIT MS1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 11455.7 | 6348.1 | 8.14 | 4 |
| SPLIT MS2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 11441.8 | 6340.3 | 8.14 | 4 |
| SPLIT TSW HEATING COIL | Coil:Heating:DX:SingleSpeed | 7151.3 | 3968.2 | 8.11 | 4 |
| SPLIT TNW HEATING COIL | Coil:Heating:DX:SingleSpeed | 7225.4 | 4010.1 | 8.11 | 4 |
| SPLIT TSE HEATING COIL | Coil:Heating:DX:SingleSpeed | 6612.6 | 3667.3 | 8.10 | 4 |
| SPLIT TNE HEATING COIL | Coil:Heating:DX:SingleSpeed | 6681.9 | 3706.5 | 8.10 | 4 |
| SPLIT TN1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 6207.2 | 3443.0 | 8.16 | 4 |
| SPLIT TN2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 6187.6 | 3432.0 | 8.16 | 4 |
| SPLIT TS1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 6142.5 | 3406.2 | 8.16 | 4 |
| SPLIT TS2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 6123.1 | 3395.4 | 8.16 | 4 |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
| SPLIT GSW HEATING COIL | Coil:Heating:DX:SingleSpeed | 5881.00 | 3.81 | |
| SPLIT GSW_SUPPHEATCOIL | Coil:Heating:Electric | 5881.00 | 1.00 | |
| SPLIT GNW HEATING COIL | Coil:Heating:DX:SingleSpeed | 5900.19 | 3.81 | |
| SPLIT GNW_SUPPHEATCOIL | Coil:Heating:Electric | 5900.19 | 1.00 | |
| SPLIT OFFICE HEATING COIL | Coil:Heating:DX:SingleSpeed | 6944.57 | 3.81 | |
| SPLIT OFFICE_SUPPHEATCOIL | Coil:Heating:Electric | 6944.57 | 1.00 | |
| SPLIT GNE HEATING COIL | Coil:Heating:DX:SingleSpeed | 5611.16 | 3.81 | |
| SPLIT GNE_SUPPHEATCOIL | Coil:Heating:Electric | 5611.16 | 1.00 | |
| SPLIT GN1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5069.03 | 3.81 | |
| SPLIT GN1_SUPPHEATCOIL | Coil:Heating:Electric | 5069.03 | 1.00 | |
| SPLIT GN2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5063.22 | 3.81 | |
| SPLIT GN2_SUPPHEATCOIL | Coil:Heating:Electric | 5063.22 | 1.00 | |
| SPLIT GS1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5082.78 | 3.81 | |
| SPLIT GS1_SUPPHEATCOIL | Coil:Heating:Electric | 5082.78 | 1.00 | |
| SPLIT GS2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5124.92 | 3.81 | |
| SPLIT GS2_SUPPHEATCOIL | Coil:Heating:Electric | 5124.92 | 1.00 | |
| SPLIT MSW HEATING COIL | Coil:Heating:DX:SingleSpeed | 12843.65 | 3.81 | |
| SPLIT MSW_SUPPHEATCOIL | Coil:Heating:Electric | 12843.65 | 1.00 | |
| SPLIT MNW HEATING COIL | Coil:Heating:DX:SingleSpeed | 12898.91 | 3.81 | |
| SPLIT MNW_SUPPHEATCOIL | Coil:Heating:Electric | 12898.91 | 1.00 | |
| SPLIT MSE HEATING COIL | Coil:Heating:DX:SingleSpeed | 12146.23 | 3.81 | |
| SPLIT MSE_SUPPHEATCOIL | Coil:Heating:Electric | 12146.23 | 1.00 | |
| SPLIT MNE HEATING COIL | Coil:Heating:DX:SingleSpeed | 12183.91 | 3.81 | |
| SPLIT MNE_SUPPHEATCOIL | Coil:Heating:Electric | 12183.91 | 1.00 | |
| SPLIT MN1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 10992.24 | 3.81 | |
| SPLIT MN1_SUPPHEATCOIL | Coil:Heating:Electric | 10992.24 | 1.00 | |
| SPLIT MN2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 10978.77 | 3.81 | |
| SPLIT MN2_SUPPHEATCOIL | Coil:Heating:Electric | 10978.77 | 1.00 | |
| SPLIT MS1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 11000.75 | 3.81 | |
| SPLIT MS1_SUPPHEATCOIL | Coil:Heating:Electric | 11000.75 | 1.00 | |
| SPLIT MS2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 10987.57 | 3.81 | |
| SPLIT MS2_SUPPHEATCOIL | Coil:Heating:Electric | 10987.57 | 1.00 | |
| SPLIT TSW HEATING COIL | Coil:Heating:DX:SingleSpeed | 6855.57 | 3.81 | |
| SPLIT TSW_SUPPHEATCOIL | Coil:Heating:Electric | 6855.57 | 1.00 | |
| SPLIT TNW HEATING COIL | Coil:Heating:DX:SingleSpeed | 6925.23 | 3.81 | |
| SPLIT TNW_SUPPHEATCOIL | Coil:Heating:Electric | 6925.23 | 1.00 | |
| SPLIT TSE HEATING COIL | Coil:Heating:DX:SingleSpeed | 6343.61 | 3.81 | |
| SPLIT TSE_SUPPHEATCOIL | Coil:Heating:Electric | 6343.61 | 1.00 | |
| SPLIT TNE HEATING COIL | Coil:Heating:DX:SingleSpeed | 6408.42 | 3.81 | |
| SPLIT TNE_SUPPHEATCOIL | Coil:Heating:Electric | 6408.42 | 1.00 | |
| SPLIT TN1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5953.58 | 3.81 | |
| SPLIT TN1_SUPPHEATCOIL | Coil:Heating:Electric | 5953.58 | 1.00 | |
| SPLIT TN2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5934.90 | 3.81 | |
| SPLIT TN2_SUPPHEATCOIL | Coil:Heating:Electric | 5934.90 | 1.00 | |
| SPLIT TS1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5893.41 | 3.81 | |
| SPLIT TS1_SUPPHEATCOIL | Coil:Heating:Electric | 5893.41 | 1.00 | |
| SPLIT TS2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5874.94 | 3.81 | |
| SPLIT TS2_SUPPHEATCOIL | Coil:Heating:Electric | 5874.94 | 1.00 |
| Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
| G SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| M SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M SE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M SE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| T SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T SE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T SE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 350.37 | 1120.11 | 1.00 | 1.87 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.32 | 354.11 | 1120.11 | 1.00 | 1.86 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.37 | 416.98 | 1120.11 | 1.00 | 1.76 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 09:20:00 |
| SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.30 | 332.50 | 1120.11 | 1.00 | 1.90 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 295.48 | 1120.11 | 1.00 | 1.99 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 295.05 | 1120.11 | 1.00 | 1.99 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 291.96 | 1120.11 | 1.00 | 2.00 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 294.99 | 1120.11 | 1.00 | 1.99 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.69 | 773.46 | 1120.11 | 1.00 | 1.48 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.70 | 781.47 | 1120.11 | 1.00 | 1.48 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.64 | 719.85 | 1120.11 | 1.00 | 1.51 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.65 | 727.87 | 1120.11 | 1.00 | 1.50 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.58 | 647.62 | 1120.11 | 1.00 | 1.54 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.58 | 646.63 | 1120.11 | 1.00 | 1.55 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.57 | 639.64 | 1120.11 | 1.00 | 1.55 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.57 | 638.64 | 1120.11 | 1.00 | 1.55 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.37 | 416.24 | 1120.11 | 1.00 | 1.76 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.38 | 422.63 | 1120.11 | 1.00 | 1.75 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.34 | 378.48 | 1120.11 | 1.00 | 1.82 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.34 | 384.86 | 1120.11 | 1.00 | 1.81 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.32 | 356.92 | 1120.11 | 1.00 | 1.85 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.32 | 355.55 | 1120.11 | 1.00 | 1.86 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 350.49 | 1120.11 | 1.00 | 1.87 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 349.12 | 1120.11 | 1.00 | 1.87 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 |
| Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
| SWHSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 29891.00 | 0.000113 | 14.49 | 127739.32 | 0.30 | General |
| Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
| SWHSYS1 WATER HEATER | WaterHeater:Mixed | 0.95 | 53912.00 | 0.80 | 11.45 | 0.46 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
Zone Sensible Cooling| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| G SW APARTMENT | 3699.59 | 4439.50 | 50.31 | 0.261 | 0.313 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00828 | 31.89 | 0.01715 | 0.026 | 0.00 |
| G NW APARTMENT | 3738.26 | 4485.91 | 50.83 | 0.263 | 0.316 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00823 | 31.89 | 0.01715 | 0.026 | 0.00 |
| OFFICE | 4226.04 | 5071.25 | 57.47 | 0.310 | 0.372 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 09:20:00 | 23.90 | 23.90 | 0.00810 | 31.01 | 0.01715 | 0.038 | 0.00 |
| G NE APARTMENT | 3515.29 | 4218.35 | 47.80 | 0.247 | 0.297 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00826 | 31.89 | 0.01715 | 0.026 | 0.00 |
| G N1 APARTMENT | 3135.41 | 3762.49 | 42.63 | 0.220 | 0.264 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00825 | 31.89 | 0.01715 | 0.026 | 0.00 |
| G N2 APARTMENT | 3130.96 | 3757.16 | 42.57 | 0.220 | 0.263 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00826 | 31.89 | 0.01715 | 0.026 | 0.00 |
| G S1 APARTMENT | 3098.86 | 3718.63 | 42.14 | 0.217 | 0.261 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00836 | 31.89 | 0.01715 | 0.026 | 0.00 |
| G S2 APARTMENT | 3130.18 | 3756.21 | 42.56 | 0.219 | 0.263 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00836 | 31.89 | 0.01715 | 0.026 | 0.00 |
| M SW APARTMENT | 8148.18 | 9777.82 | 110.80 | 0.575 | 0.691 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00829 | 31.89 | 0.01715 | 0.052 | 0.00 |
| M NW APARTMENT | 8230.35 | 9876.42 | 111.92 | 0.581 | 0.698 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00826 | 31.89 | 0.01715 | 0.052 | 0.00 |
| M SE APARTMENT | 7597.49 | 9116.99 | 103.31 | 0.536 | 0.643 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00834 | 31.89 | 0.01715 | 0.052 | 0.00 |
| M NE APARTMENT | 7680.70 | 9216.84 | 104.44 | 0.542 | 0.650 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00829 | 31.89 | 0.01715 | 0.052 | 0.00 |
| M N1 APARTMENT | 6851.57 | 8221.89 | 93.17 | 0.482 | 0.578 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00828 | 31.89 | 0.01715 | 0.052 | 0.00 |
| M N2 APARTMENT | 6841.34 | 8209.60 | 93.03 | 0.481 | 0.577 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00828 | 31.89 | 0.01715 | 0.052 | 0.00 |
| M S1 APARTMENT | 6769.38 | 8123.26 | 92.05 | 0.476 | 0.571 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00837 | 31.89 | 0.01715 | 0.052 | 0.00 |
| M S2 APARTMENT | 6759.11 | 8110.93 | 91.91 | 0.475 | 0.570 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00837 | 31.89 | 0.01715 | 0.052 | 0.00 |
| T SW APARTMENT | 4378.93 | 5254.72 | 59.54 | 0.310 | 0.372 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00829 | 31.89 | 0.01715 | 0.026 | 0.00 |
| T NW APARTMENT | 4444.76 | 5333.71 | 60.44 | 0.314 | 0.377 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00827 | 31.89 | 0.01715 | 0.026 | 0.00 |
| T SE APARTMENT | 3990.58 | 4788.70 | 54.26 | 0.282 | 0.338 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00834 | 31.89 | 0.01715 | 0.026 | 0.00 |
| T NE APARTMENT | 4056.06 | 4867.27 | 55.15 | 0.286 | 0.344 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00831 | 31.89 | 0.01715 | 0.026 | 0.00 |
| T N1 APARTMENT | 3769.55 | 4523.46 | 51.26 | 0.266 | 0.319 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00824 | 31.89 | 0.01715 | 0.026 | 0.00 |
| T N2 APARTMENT | 3755.54 | 4506.64 | 51.07 | 0.265 | 0.317 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00825 | 31.89 | 0.01715 | 0.026 | 0.00 |
| T S1 APARTMENT | 3703.66 | 4444.40 | 50.36 | 0.261 | 0.313 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00829 | 31.89 | 0.01715 | 0.026 | 0.00 |
| T S2 APARTMENT | 3689.63 | 4427.56 | 50.17 | 0.260 | 0.312 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 24.00 | 24.00 | 0.00829 | 31.89 | 0.01715 | 0.026 | 0.00 |
| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| G SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 24.39 | 0.01480 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| G NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 24.91 | 0.01998 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| OFFICE | 0.00 | 0.00 | 0.00 | 0.000 | 0.038 | 00:10:00 | 21.10 | 22.52 | 0.01480 | 20.10 | 0.01480 | 0.038 | 0.00 | |
| G NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 24.91 | 0.01998 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| G N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 25.53 | 0.02076 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| G N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 25.53 | 0.02076 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| G S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 24.92 | 0.01480 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| G S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 24.68 | 0.01480 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| M SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.052 | 00:10:00 | 21.10 | 24.34 | 0.01480 | 20.10 | 0.01480 | 0.052 | 0.00 | |
| M NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.052 | 00:10:00 | 21.10 | 25.00 | 0.02010 | 20.10 | 0.01480 | 0.052 | 0.00 | |
| M SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.052 | 00:10:00 | 21.10 | 24.34 | 0.01480 | 20.10 | 0.01480 | 0.052 | 0.00 | |
| M NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.052 | 00:10:00 | 21.10 | 25.00 | 0.02010 | 20.10 | 0.01480 | 0.052 | 0.00 | |
| M N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.052 | 00:10:00 | 21.10 | 25.86 | 0.02119 | 20.10 | 0.01480 | 0.052 | 0.00 | |
| M N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.052 | 00:10:00 | 21.10 | 25.86 | 0.02119 | 20.10 | 0.01480 | 0.052 | 0.00 | |
| M S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.052 | 00:10:00 | 21.10 | 25.14 | 0.01480 | 20.10 | 0.01480 | 0.052 | 0.00 | |
| M S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.052 | 00:10:00 | 21.10 | 25.14 | 0.01480 | 20.10 | 0.01480 | 0.052 | 0.00 | |
| T SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 22.53 | 0.01480 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| T NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 23.26 | 0.01804 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| T SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 22.53 | 0.01480 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| T NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 23.26 | 0.01804 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| T N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 23.94 | 0.01883 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| T N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 23.94 | 0.01883 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| T S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 23.14 | 0.01480 | 20.10 | 0.01480 | 0.026 | 0.00 | |
| T S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.026 | 00:10:00 | 21.10 | 23.14 | 0.01480 | 20.10 | 0.01480 | 0.026 | 0.00 |
| Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
| SPLIT GSW | 0.31 | 0.31 | 0.03 | 0.03 | 0.3128 | 0.3128 | 0.3128 | 1.0000 | 1.0000 |
| SPLIT GNW | 0.32 | 0.32 | 0.03 | 0.03 | 0.3161 | 0.3161 | 0.3161 | 1.0000 | 1.0000 |
| SPLIT OFFICE | 0.37 | 0.37 | 0.04 | 0.04 | 0.3723 | 0.3723 | 0.3723 | 1.0000 | 1.0000 |
| SPLIT GNE | 0.30 | 0.30 | 0.03 | 0.03 | 0.2968 | 0.2968 | 0.2968 | 1.0000 | 1.0000 |
| SPLIT GN1 | 0.26 | 0.26 | 0.03 | 0.03 | 0.2638 | 0.2638 | 0.2638 | 1.0000 | 1.0000 |
| SPLIT GN2 | 0.26 | 0.26 | 0.03 | 0.03 | 0.2634 | 0.2634 | 0.2634 | 1.0000 | 1.0000 |
| SPLIT GS1 | 0.26 | 0.26 | 0.03 | 0.03 | 0.2606 | 0.2606 | 0.2606 | 1.0000 | 1.0000 |
| SPLIT GS2 | 0.26 | 0.26 | 0.03 | 0.03 | 0.2634 | 0.2634 | 0.2634 | 1.0000 | 1.0000 |
| SPLIT MSW | 0.69 | 0.69 | 0.05 | 0.05 | 0.6905 | 0.6905 | 0.6905 | 1.0000 | 1.0000 |
| SPLIT MNW | 0.70 | 0.70 | 0.05 | 0.05 | 0.6977 | 0.6977 | 0.6977 | 1.0000 | 1.0000 |
| SPLIT MSE | 0.64 | 0.64 | 0.05 | 0.05 | 0.6427 | 0.6427 | 0.6427 | 1.0000 | 1.0000 |
| SPLIT MNE | 0.65 | 0.65 | 0.05 | 0.05 | 0.6498 | 0.6498 | 0.6498 | 1.0000 | 1.0000 |
| SPLIT MN1 | 0.58 | 0.58 | 0.05 | 0.05 | 0.5782 | 0.5782 | 0.5782 | 1.0000 | 1.0000 |
| SPLIT MN2 | 0.58 | 0.58 | 0.05 | 0.05 | 0.5773 | 0.5773 | 0.5773 | 1.0000 | 1.0000 |
| SPLIT MS1 | 0.57 | 0.57 | 0.05 | 0.05 | 0.5711 | 0.5711 | 0.5711 | 1.0000 | 1.0000 |
| SPLIT MS2 | 0.57 | 0.57 | 0.05 | 0.05 | 0.5702 | 0.5702 | 0.5702 | 1.0000 | 1.0000 |
| SPLIT TSW | 0.37 | 0.37 | 0.03 | 0.03 | 0.3716 | 0.3716 | 0.3716 | 1.0000 | 1.0000 |
| SPLIT TNW | 0.38 | 0.38 | 0.03 | 0.03 | 0.3773 | 0.3773 | 0.3773 | 1.0000 | 1.0000 |
| SPLIT TSE | 0.34 | 0.34 | 0.03 | 0.03 | 0.3379 | 0.3379 | 0.3379 | 1.0000 | 1.0000 |
| SPLIT TNE | 0.34 | 0.34 | 0.03 | 0.03 | 0.3436 | 0.3436 | 0.3436 | 1.0000 | 1.0000 |
| SPLIT TN1 | 0.32 | 0.32 | 0.03 | 0.03 | 0.3186 | 0.3186 | 0.3186 | 1.0000 | 1.0000 |
| SPLIT TN2 | 0.32 | 0.32 | 0.03 | 0.03 | 0.3174 | 0.3174 | 0.3174 | 1.0000 | 1.0000 |
| SPLIT TS1 | 0.31 | 0.31 | 0.03 | 0.03 | 0.3129 | 0.3129 | 0.3129 | 1.0000 | 1.0000 |
| SPLIT TS2 | 0.31 | 0.31 | 0.03 | 0.03 | 0.3117 | 0.3117 | 0.3117 | 1.0000 | 1.0000 |
| Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
| None |
| Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
| SPLIT GSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GSW | 5881.001 | 4708.938 | 0.312800 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 5719.90 | 4889.36 | 0.312800 | 25.60 | 17.37 | 0.00901314 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 8.2975 | 24.00 | 0.00827673 | 44.5507 | 3699.59 | 0.00 | 5880.00 | 4704.38 |
| SPLIT GSW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT GSW | 5881.001 | 5881.001 | 0.312800 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 5881.00 | 5881.00 | 0.312800 | 21.02 | 15.36 | 0.00856409 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.2975 | 24.39 | 0.01479830 | 77.0017 | 0.00 | 0.00 | 5888.73 | 5888.73 |
| SPLIT GSW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT GSW | 5881.001 | 5881.001 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 5881.00 | 5881.00 | 0.312800 | 21.02 | 15.36 | 0.00856409 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.2975 | 24.39 | 0.01479830 | 77.0017 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT GNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GNW | 5900.194 | 4720.698 | 0.316136 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 5732.47 | 4935.08 | 0.316136 | 25.59 | 17.33 | 0.00896333 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 8.2099 | 24.00 | 0.00823093 | 44.3071 | 3738.26 | 0.00 | 5899.19 | 4715.14 |
| SPLIT GNW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT GNW | 5900.194 | 5900.194 | 0.316136 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 5900.19 | 5900.19 | 0.316136 | 21.02 | 15.36 | 0.00855814 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.2099 | 24.91 | 0.01998254 | 99.9999 | 0.00 | 0.00 | 5907.95 | 5907.95 |
| SPLIT GNW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT GNW | 5900.194 | 5900.194 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 5900.19 | 5900.19 | 0.316136 | 21.02 | 15.36 | 0.00855814 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.2099 | 24.91 | 0.01998254 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT OFFICE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT OFFICE | 6944.565 | 5557.362 | 0.372271 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 09:20:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 09:20:00 | 6796.20 | 5795.79 | 0.372271 | 25.54 | 17.36 | 0.00902549 | 12.80 | 11.59 | 0.00800000 | 31.01 | 0.01715015 | 24.76 | 10.2361 | 23.90 | 0.00809900 | 43.8678 | 4226.04 | 0.00 | 6943.38 | 5550.90 |
| SPLIT OFFICE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT OFFICE | 6944.565 | 6944.565 | 0.372271 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 6944.57 | 6944.57 | 0.372271 | 21.00 | 15.47 | 0.00869588 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 10.2361 | 22.52 | 0.01479830 | 86.2214 | 0.00 | 0.00 | 6953.69 | 6953.69 |
| SPLIT OFFICE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT OFFICE | 6944.565 | 6944.565 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 6944.57 | 6944.57 | 0.372271 | 21.00 | 15.47 | 0.00869588 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 10.2361 | 22.52 | 0.01479830 | 86.2214 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT GNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GNE | 5611.155 | 4483.142 | 0.296849 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 5461.81 | 4652.29 | 0.296849 | 25.63 | 17.41 | 0.00903990 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 8.7434 | 24.00 | 0.00826269 | 44.4759 | 3515.29 | 0.00 | 5610.20 | 4477.87 |
| SPLIT GNE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT GNE | 5611.155 | 5611.155 | 0.296849 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 5611.16 | 5611.16 | 0.296849 | 21.01 | 15.39 | 0.00859440 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.7434 | 24.91 | 0.01998254 | 99.9999 | 0.00 | 0.00 | 5618.53 | 5618.53 |
| SPLIT GNE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT GNE | 5611.155 | 5611.155 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 5611.16 | 5611.16 | 0.296849 | 21.01 | 15.39 | 0.00859440 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.7434 | 24.91 | 0.01998254 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT GN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GN1 | 5069.026 | 4018.302 | 0.263793 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 4946.26 | 4163.01 | 0.263793 | 25.70 | 17.51 | 0.00913002 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 9.8390 | 24.00 | 0.00825463 | 44.4329 | 3135.41 | 0.00 | 5068.16 | 4014.29 |
| SPLIT GN1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT GN1 | 5069.026 | 5069.026 | 0.263793 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 5069.03 | 5069.03 | 0.263793 | 21.00 | 15.45 | 0.00866888 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 9.8390 | 25.53 | 0.02075559 | 99.9999 | 0.00 | 0.00 | 5075.69 | 5075.69 |
| SPLIT GN1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT GN1 | 5069.026 | 5069.026 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 5069.03 | 5069.03 | 0.263793 | 21.00 | 15.45 | 0.00866888 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 9.8390 | 25.53 | 0.02075559 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT GN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GN2 | 5063.222 | 4013.213 | 0.263411 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 4940.82 | 4157.37 | 0.263411 | 25.70 | 17.51 | 0.00913191 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 9.8533 | 24.00 | 0.00825531 | 44.4365 | 3130.96 | 0.00 | 5062.36 | 4009.15 |
| SPLIT GN2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT GN2 | 5063.222 | 5063.222 | 0.263411 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 5063.22 | 5063.22 | 0.263411 | 21.00 | 15.45 | 0.00866985 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 9.8533 | 25.53 | 0.02075559 | 99.9999 | 0.00 | 0.00 | 5069.88 | 5069.88 |
| SPLIT GN2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT GN2 | 5063.222 | 5063.222 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 5063.22 | 5063.22 | 0.263411 | 21.00 | 15.45 | 0.00866985 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 9.8533 | 25.53 | 0.02075559 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT GS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GS1 | 5082.778 | 3995.551 | 0.260650 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 4970.54 | 4122.75 | 0.260650 | 25.71 | 17.60 | 0.00923565 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 9.9576 | 24.00 | 0.00836022 | 44.9944 | 3098.86 | 0.00 | 5081.91 | 3991.04 |
| SPLIT GS1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT GS1 | 5082.778 | 5082.778 | 0.260650 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 5082.78 | 5082.78 | 0.260650 | 21.00 | 15.46 | 0.00867695 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 9.9576 | 24.92 | 0.01479830 | 74.5978 | 0.00 | 0.00 | 5089.46 | 5089.46 |
| SPLIT GS1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT GS1 | 5082.778 | 5082.778 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 5082.78 | 5082.78 | 0.260650 | 21.00 | 15.46 | 0.00867695 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 9.9576 | 24.92 | 0.01479830 | 74.5978 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT GS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GS2 | 5124.921 | 4032.016 | 0.263359 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 5010.17 | 4162.65 | 0.263359 | 25.70 | 17.58 | 0.00922284 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 9.8552 | 24.00 | 0.00835600 | 44.9720 | 3130.18 | 0.00 | 5124.05 | 4027.80 |
| SPLIT GS2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT GS2 | 5124.921 | 5124.921 | 0.263359 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 5124.92 | 5124.92 | 0.263359 | 21.00 | 15.45 | 0.00866999 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 9.8552 | 24.68 | 0.01479830 | 75.6975 | 0.00 | 0.00 | 5131.66 | 5131.66 |
| SPLIT GS2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT GS2 | 5124.921 | 5124.921 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 5124.92 | 5124.92 | 0.263359 | 21.00 | 15.45 | 0.00866999 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 9.8552 | 24.68 | 0.01479830 | 75.6975 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT MSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MSW | 12843.655 | 10277.568 | 0.690522 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 12472.05 | 10741.49 | 0.690522 | 25.54 | 17.31 | 0.00895752 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 7.5174 | 24.00 | 0.00829145 | 44.6290 | 16296.36 | 0.00 | 12841.47 | 10266.48 |
| SPLIT MSW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MSW | 12843.655 | 12843.655 | 0.690522 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 12843.65 | 12843.65 | 0.690522 | 21.02 | 15.32 | 0.00851105 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 7.5174 | 24.34 | 0.01479830 | 77.2665 | 0.00 | 0.00 | 12860.53 | 12860.53 |
| SPLIT MSW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MSW | 12843.655 | 12843.655 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 12843.65 | 12843.65 | 0.690522 | 21.02 | 15.32 | 0.00851105 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 7.5174 | 24.34 | 0.01479830 | 77.2665 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT MNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MNW | 12898.907 | 10321.419 | 0.697672 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 12514.91 | 10840.54 | 0.697672 | 25.54 | 17.27 | 0.00891764 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 7.4403 | 24.00 | 0.00825574 | 44.4391 | 16460.70 | 0.00 | 12896.71 | 10311.97 |
| SPLIT MNW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MNW | 12898.907 | 12898.907 | 0.697672 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 12898.91 | 12898.91 | 0.697672 | 21.03 | 15.31 | 0.00850582 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 7.4403 | 25.00 | 0.02010062 | 99.9999 | 0.00 | 0.00 | 12915.86 | 12915.86 |
| SPLIT MNW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MNW | 12898.907 | 12898.907 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 12898.91 | 12898.91 | 0.697672 | 21.03 | 15.31 | 0.00850582 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 7.4403 | 25.00 | 0.02010062 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT MSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MSE | 12146.232 | 9717.126 | 0.642660 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 11822.39 | 10042.89 | 0.642660 | 25.58 | 17.40 | 0.00905582 | 12.80 | 11.59 | 0.00800000 | 31.88 | 0.01715183 | 24.99 | 8.0772 | 24.00 | 0.00834443 | 44.9106 | 15194.98 | 0.00 | 12144.16 | 9693.11 |
| SPLIT MSE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MSE | 12146.232 | 12146.232 | 0.642660 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 12146.23 | 12146.23 | 0.642660 | 21.02 | 15.35 | 0.00854911 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.0772 | 24.34 | 0.01479830 | 77.2665 | 0.00 | 0.00 | 12162.19 | 12162.19 |
| SPLIT MSE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MSE | 12146.232 | 12146.232 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 12146.23 | 12146.23 | 0.642660 | 21.02 | 15.35 | 0.00854911 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.0772 | 24.34 | 0.01479830 | 77.2665 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT MNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MNE | 12183.913 | 9754.359 | 0.649822 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 11845.31 | 10140.83 | 0.649822 | 25.58 | 17.36 | 0.00900117 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 7.9882 | 24.00 | 0.00829356 | 44.6401 | 15361.40 | 0.00 | 12181.84 | 9745.71 |
| SPLIT MNE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MNE | 12183.913 | 12183.913 | 0.649822 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 12183.91 | 12183.91 | 0.649822 | 21.02 | 15.34 | 0.00854306 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 7.9882 | 25.00 | 0.02010062 | 99.9999 | 0.00 | 0.00 | 12199.92 | 12199.92 |
| SPLIT MNE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MNE | 12183.913 | 12183.913 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 12183.91 | 12183.91 | 0.649822 | 21.02 | 15.34 | 0.00854306 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 7.9882 | 25.00 | 0.02010062 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT MN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MN1 | 10992.238 | 8762.081 | 0.578177 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 10708.80 | 9077.42 | 0.578177 | 25.64 | 17.44 | 0.00907519 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 8.9781 | 24.00 | 0.00827854 | 44.5601 | 13703.14 | 0.00 | 10990.37 | 8753.45 |
| SPLIT MN1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MN1 | 10992.238 | 10992.238 | 0.578177 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 10992.24 | 10992.24 | 0.578177 | 21.01 | 15.40 | 0.00861036 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.9781 | 25.86 | 0.02118516 | 99.9999 | 0.00 | 0.00 | 11006.68 | 11006.68 |
| SPLIT MN1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MN1 | 10992.238 | 10992.238 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 10992.24 | 10992.24 | 0.578177 | 21.01 | 15.40 | 0.00861036 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.9781 | 25.86 | 0.02118516 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT MN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MN2 | 10978.765 | 8750.252 | 0.577289 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 10696.17 | 9064.37 | 0.577289 | 25.64 | 17.44 | 0.00907707 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 8.9919 | 24.00 | 0.00827926 | 44.5640 | 13682.67 | 0.00 | 10976.90 | 8741.53 |
| SPLIT MN2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MN2 | 10978.765 | 10978.765 | 0.577289 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 10978.77 | 10978.77 | 0.577289 | 21.01 | 15.40 | 0.00861129 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.9919 | 25.86 | 0.02118516 | 99.9999 | 0.00 | 0.00 | 10993.19 | 10993.19 |
| SPLIT MN2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MN2 | 10978.765 | 10978.765 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 10978.77 | 10978.77 | 0.577289 | 21.01 | 15.40 | 0.00861129 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.9919 | 25.86 | 0.02118516 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT MS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MS1 | 11000.750 | 8700.793 | 0.571054 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 10737.91 | 8984.52 | 0.571054 | 25.65 | 17.52 | 0.00916810 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 9.0900 | 24.00 | 0.00836981 | 45.0454 | 13538.76 | 0.00 | 10998.88 | 8691.39 |
| SPLIT MS1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MS1 | 11000.750 | 11000.750 | 0.571054 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 11000.75 | 11000.75 | 0.571054 | 21.01 | 15.41 | 0.00861797 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 9.0900 | 25.14 | 0.01479830 | 73.6243 | 0.00 | 0.00 | 11015.21 | 11015.21 |
| SPLIT MS1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MS1 | 11000.750 | 11000.750 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 11000.75 | 11000.75 | 0.571054 | 21.01 | 15.41 | 0.00861797 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 9.0900 | 25.14 | 0.01479830 | 73.6243 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT MS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MS2 | 10987.566 | 8689.101 | 0.570162 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 10725.63 | 8971.44 | 0.570162 | 25.65 | 17.52 | 0.00917041 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 9.1043 | 24.00 | 0.00837097 | 45.0516 | 13518.21 | 0.00 | 10985.70 | 8679.58 |
| SPLIT MS2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MS2 | 10987.566 | 10987.566 | 0.570162 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 10987.57 | 10987.57 | 0.570162 | 21.01 | 15.41 | 0.00861894 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 9.1043 | 25.14 | 0.01479830 | 73.6243 | 0.00 | 0.00 | 11002.01 | 11002.01 |
| SPLIT MS2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MS2 | 10987.566 | 10987.566 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 10987.57 | 10987.57 | 0.570162 | 21.01 | 15.41 | 0.00861894 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 9.1043 | 25.14 | 0.01479830 | 73.6243 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT TSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TSW | 6855.572 | 5490.597 | 0.371611 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 6649.30 | 5761.86 | 0.371611 | 25.51 | 17.26 | 0.00891332 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 6.9843 | 24.00 | 0.00829471 | 44.6464 | 4378.93 | 0.00 | 6854.41 | 5483.56 |
| SPLIT TSW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TSW | 6855.572 | 6855.572 | 0.371611 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 6855.57 | 6855.57 | 0.371611 | 21.03 | 15.29 | 0.00847482 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 6.9843 | 22.53 | 0.01479830 | 86.1699 | 0.00 | 0.00 | 6864.58 | 6864.58 |
| SPLIT TSW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TSW | 6855.572 | 6855.572 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 6855.57 | 6855.57 | 0.371611 | 21.03 | 15.29 | 0.00847482 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 6.9843 | 22.53 | 0.01479830 | 86.1699 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT TNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TNW | 6925.227 | 5544.262 | 0.377314 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 6711.94 | 5843.59 | 0.377314 | 25.50 | 17.23 | 0.00888076 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 6.8788 | 24.00 | 0.00826978 | 44.5138 | 4444.76 | 0.00 | 6924.05 | 5537.85 |
| SPLIT TNW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TNW | 6925.227 | 6925.227 | 0.377314 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 6925.23 | 6925.23 | 0.377314 | 21.03 | 15.28 | 0.00846764 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 6.8788 | 23.26 | 0.01804278 | 99.9999 | 0.00 | 0.00 | 6934.33 | 6934.33 |
| SPLIT TNW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TNW | 6925.227 | 6925.227 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 6925.23 | 6925.23 | 0.377314 | 21.03 | 15.28 | 0.00846764 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 6.8788 | 23.26 | 0.01804278 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT TSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TSE | 6343.608 | 5076.013 | 0.337899 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 6168.38 | 5267.94 | 0.337899 | 25.56 | 17.36 | 0.00901694 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 7.6812 | 24.00 | 0.00834010 | 44.8876 | 3990.58 | 0.00 | 6342.53 | 5071.28 |
| SPLIT TSE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TSE | 6343.608 | 6343.608 | 0.337899 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 6343.61 | 6343.61 | 0.337899 | 21.02 | 15.33 | 0.00852219 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 7.6812 | 22.53 | 0.01479830 | 86.1699 | 0.00 | 0.00 | 6351.94 | 6351.94 |
| SPLIT TSE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TSE | 6343.608 | 6343.608 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 6343.61 | 6343.61 | 0.337899 | 21.02 | 15.33 | 0.00852219 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 7.6812 | 22.53 | 0.01479830 | 86.1699 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT TNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TNE | 6408.419 | 5128.672 | 0.343589 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 6225.50 | 5349.03 | 0.343589 | 25.55 | 17.33 | 0.00897428 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 7.5540 | 24.00 | 0.00830608 | 44.7067 | 4056.06 | 0.00 | 6407.33 | 5122.74 |
| SPLIT TNE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TNE | 6408.419 | 6408.419 | 0.343589 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 6408.42 | 6408.42 | 0.343589 | 21.02 | 15.32 | 0.00851354 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 7.5540 | 23.26 | 0.01804278 | 99.9999 | 0.00 | 0.00 | 6416.84 | 6416.84 |
| SPLIT TNE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TNE | 6408.419 | 6408.419 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 6408.42 | 6408.42 | 0.343589 | 21.02 | 15.32 | 0.00851354 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 7.5540 | 23.26 | 0.01804278 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT TN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TN1 | 5953.579 | 4767.222 | 0.318645 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 5785.26 | 4975.80 | 0.318645 | 25.59 | 17.34 | 0.00897008 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 8.1453 | 24.00 | 0.00824456 | 44.3795 | 3769.55 | 0.00 | 5952.57 | 4761.49 |
| SPLIT TN1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TN1 | 5953.579 | 5953.579 | 0.318645 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 5953.58 | 5953.58 | 0.318645 | 21.02 | 15.35 | 0.00855374 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.1453 | 23.94 | 0.01882666 | 99.9999 | 0.00 | 0.00 | 5961.40 | 5961.40 |
| SPLIT TN1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TN1 | 5953.579 | 5953.579 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 5953.58 | 5953.58 | 0.318645 | 21.02 | 15.35 | 0.00855374 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.1453 | 23.94 | 0.01882666 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT TN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TN2 | 5934.898 | 4750.918 | 0.317424 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 5767.70 | 4957.91 | 0.317424 | 25.60 | 17.34 | 0.00897412 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 8.1766 | 24.00 | 0.00824592 | 44.3867 | 3755.54 | 0.00 | 5933.89 | 4745.09 |
| SPLIT TN2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TN2 | 5934.898 | 5934.898 | 0.317424 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 5934.90 | 5934.90 | 0.317424 | 21.02 | 15.35 | 0.00855587 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.1766 | 23.94 | 0.01882666 | 99.9999 | 0.00 | 0.00 | 5942.70 | 5942.70 |
| SPLIT TN2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TN2 | 5934.898 | 5934.898 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 5934.90 | 5934.90 | 0.317424 | 21.02 | 15.35 | 0.00855587 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.1766 | 23.94 | 0.01882666 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT TS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TS1 | 5893.408 | 4715.507 | 0.312907 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 5733.47 | 4894.60 | 0.312907 | 25.60 | 17.38 | 0.00902273 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 8.2947 | 24.00 | 0.00828746 | 44.6076 | 3703.66 | 0.00 | 5892.40 | 4710.62 |
| SPLIT TS1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TS1 | 5893.408 | 5893.408 | 0.312907 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 5893.41 | 5893.41 | 0.312907 | 21.02 | 15.36 | 0.00856390 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.2947 | 23.14 | 0.01479830 | 83.0225 | 0.00 | 0.00 | 5901.15 | 5901.15 |
| SPLIT TS1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TS1 | 5893.408 | 5893.408 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 5893.41 | 5893.41 | 0.312907 | 21.02 | 15.36 | 0.00856390 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.2947 | 23.14 | 0.01479830 | 83.0225 | 0.00 | 0.00 | -999.00 | -999.00 |
| SPLIT TS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TS2 | 5874.939 | 4705.126 | 0.311683 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | 5716.15 | 4876.69 | 0.311683 | 25.61 | 17.39 | 0.00902737 | 12.80 | 11.59 | 0.00800000 | 31.89 | 0.01715183 | 24.99 | 8.3272 | 24.00 | 0.00828937 | 44.6178 | 3689.63 | 0.00 | 5873.94 | 4700.21 |
| SPLIT TS2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TS2 | 5874.939 | 5874.939 | 0.311683 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 5874.94 | 5874.94 | 0.311683 | 21.02 | 15.36 | 0.00856611 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.3272 | 23.14 | 0.01479830 | 83.0225 | 0.00 | 0.00 | 5882.66 | 5882.66 |
| SPLIT TS2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TS2 | 5874.939 | 5874.939 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 5874.94 | 5874.94 | 0.311683 | 21.02 | 15.36 | 0.00856611 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.3272 | 23.14 | 0.01479830 | 83.0225 | 0.00 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
Coils| Coil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
| SPLIT GSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5881.001 | 4708.938 | 0.312800 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.5950 | 1004.8586 | 1.2036 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.312800 | 0.37648455 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 5719.90 | 4889.36 | 0.9726 | 0.37648455 | 0.312800 | 25.60 | 17.37 | 0.00901314 | 48690.5 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 350.370 | 5369.53 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 8.2975 | 24.03 | 0.00827673 | 24.00 | 0.00827673 | 44.5507 | 3699.59 | 0.00 | 5880.00 | 4704.38 | 0.36161625 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.95 | 13.93 | 0.00991001 | 39062.1 | |
| SPLIT GSW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5881.001 | 5881.001 | 0.312800 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.312800 | 0.37648455 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 5881.00 | 5881.00 | 1.0000 | 0.37648455 | 0.312800 | 21.02 | 15.36 | 0.00856409 | 42871.6 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5881.00 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 8.2975 | 21.10 | 0.00800000 | 24.39 | 0.01479830 | 77.0017 | 0.00 | 0.00 | 5888.73 | 5888.73 | 0.36983195 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.70 | 20.74 | 0.00875166 | 59366.8 | |
| SPLIT GSW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5881.001 | 5881.001 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.312800 | 0.37648455 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 5881.00 | 5881.00 | 1.0000 | 0.37648455 | 0.312800 | 21.02 | 15.36 | 0.00856409 | 42871.6 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5881.00 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 8.2975 | 21.10 | 0.00800000 | 24.39 | 0.01479830 | 77.0017 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5900.194 | 4720.698 | 0.316136 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.5024 | 1004.8586 | 1.2036 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.316136 | 0.38050011 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 5732.47 | 4935.08 | 0.9716 | 0.38050011 | 0.316136 | 25.59 | 17.33 | 0.00896333 | 48557.8 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 354.107 | 5378.36 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 8.2099 | 24.04 | 0.00823093 | 24.00 | 0.00823093 | 44.3071 | 3738.26 | 0.00 | 5899.19 | 4715.14 | 0.36547323 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.06 | 13.97 | 0.00991442 | 39181.1 | |
| SPLIT GNW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5900.194 | 5900.194 | 0.316136 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.316136 | 0.38050011 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 5900.19 | 5900.19 | 1.0000 | 0.38050011 | 0.316136 | 21.02 | 15.36 | 0.00855814 | 42857.4 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5900.19 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 8.2099 | 21.10 | 0.00800000 | 24.91 | 0.01998254 | 99.9999 | 0.00 | 0.00 | 5907.95 | 5907.95 | 0.37377655 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.59 | 20.71 | 0.00875166 | 59250.2 | |
| SPLIT GNW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5900.194 | 5900.194 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.316136 | 0.38050011 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 5900.19 | 5900.19 | 1.0000 | 0.38050011 | 0.316136 | 21.02 | 15.36 | 0.00855814 | 42857.4 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5900.19 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 8.2099 | 21.10 | 0.00800000 | 24.91 | 0.01998254 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT OFFICE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6944.565 | 5557.362 | 0.372271 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.6179 | 1004.8586 | 1.2036 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.372271 | 0.44806297 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 09:20:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 09:20:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 09:20:00 | Sensible | 6796.20 | 5795.79 | 0.9786 | 0.44806297 | 0.372271 | 25.54 | 17.36 | 0.00902549 | 48662.1 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 416.983 | 6379.22 | 31.01 | 0.01715015 | 24.76 | 0.03810604 | 10.2361 | 23.90 | 0.00809900 | 23.90 | 0.00809900 | 43.8678 | 4226.04 | 0.00 | 6943.38 | 5550.90 | 0.43036787 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.06 | 13.97 | 0.00991607 | 39188.8 | |
| SPLIT OFFICE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 6944.565 | 6944.565 | 0.372271 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.372271 | 0.44806297 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 6944.57 | 6944.57 | 1.0000 | 0.44806297 | 0.372271 | 21.00 | 15.47 | 0.00869588 | 43186.6 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6944.57 | 20.10 | 0.01479830 | 20.10 | 0.03810604 | 10.2361 | 21.10 | 0.00800000 | 22.52 | 0.01479830 | 86.2214 | 0.00 | 0.00 | 6953.69 | 6953.69 | 0.44014556 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.58 | 20.71 | 0.00875166 | 59242.7 | |
| SPLIT OFFICE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6944.565 | 6944.565 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.372271 | 0.44806297 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 6944.57 | 6944.57 | 1.0000 | 0.44806297 | 0.372271 | 21.00 | 15.47 | 0.00869588 | 43186.6 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6944.57 | 20.10 | 0.01479830 | 20.10 | 0.03810604 | 10.2361 | 21.10 | 0.00800000 | 22.52 | 0.01479830 | 86.2214 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5611.155 | 4483.142 | 0.296849 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.6447 | 1004.8586 | 1.2036 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.296849 | 0.35728560 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 5461.81 | 4652.29 | 0.9734 | 0.35728560 | 0.296849 | 25.63 | 17.41 | 0.00903990 | 48789.5 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 332.503 | 5129.31 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 8.7434 | 24.03 | 0.00826269 | 24.00 | 0.00826269 | 44.4759 | 3515.29 | 0.00 | 5610.20 | 4477.87 | 0.34317552 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.91 | 13.89 | 0.00989098 | 38974.5 | |
| SPLIT GNE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5611.155 | 5611.155 | 0.296849 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.296849 | 0.35728560 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 5611.16 | 5611.16 | 1.0000 | 0.35728560 | 0.296849 | 21.01 | 15.39 | 0.00859440 | 42944.1 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5611.16 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 8.7434 | 21.10 | 0.00800000 | 24.91 | 0.01998254 | 99.9999 | 0.00 | 0.00 | 5618.53 | 5618.53 | 0.35097225 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.79 | 20.77 | 0.00875166 | 59452.6 | |
| SPLIT GNE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5611.155 | 5611.155 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.296849 | 0.35728560 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 5611.16 | 5611.16 | 1.0000 | 0.35728560 | 0.296849 | 21.01 | 15.39 | 0.00859440 | 42944.1 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5611.16 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 8.7434 | 21.10 | 0.00800000 | 24.91 | 0.01998254 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5069.026 | 4018.302 | 0.263793 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.8123 | 1004.8586 | 1.2036 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.263793 | 0.31750017 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 4946.26 | 4163.01 | 0.9758 | 0.31750017 | 0.263793 | 25.70 | 17.51 | 0.00913002 | 49096.3 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 295.477 | 4650.78 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 9.8390 | 24.02 | 0.00825463 | 24.00 | 0.00825463 | 44.4329 | 3135.41 | 0.00 | 5068.16 | 4014.29 | 0.30496132 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.80 | 13.79 | 0.00982973 | 38703.3 | |
| SPLIT GN1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5069.026 | 5069.026 | 0.263793 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.263793 | 0.31750017 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 5069.03 | 5069.03 | 1.0000 | 0.31750017 | 0.263793 | 21.00 | 15.45 | 0.00866888 | 43122.1 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5069.03 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 9.8390 | 21.10 | 0.00800000 | 25.53 | 0.02075559 | 99.9999 | 0.00 | 0.00 | 5075.69 | 5075.69 | 0.31188985 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 37.05 | 20.85 | 0.00875166 | 59718.1 | |
| SPLIT GN1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5069.026 | 5069.026 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.263793 | 0.31750017 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 5069.03 | 5069.03 | 1.0000 | 0.31750017 | 0.263793 | 21.00 | 15.45 | 0.00866888 | 43122.1 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5069.03 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 9.8390 | 21.10 | 0.00800000 | 25.53 | 0.02075559 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5063.222 | 4013.213 | 0.263411 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.8158 | 1004.8586 | 1.2036 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.263411 | 0.31704018 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 4940.82 | 4157.37 | 0.9758 | 0.31704018 | 0.263411 | 25.70 | 17.51 | 0.00913191 | 49102.0 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 295.049 | 4645.77 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 9.8533 | 24.02 | 0.00825531 | 24.00 | 0.00825531 | 44.4365 | 3130.96 | 0.00 | 5062.36 | 4009.15 | 0.30451949 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.80 | 13.79 | 0.00982863 | 38698.3 | |
| SPLIT GN2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5063.222 | 5063.222 | 0.263411 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.263411 | 0.31704018 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 5063.22 | 5063.22 | 1.0000 | 0.31704018 | 0.263411 | 21.00 | 15.45 | 0.00866985 | 43124.4 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5063.22 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 9.8533 | 21.10 | 0.00800000 | 25.53 | 0.02075559 | 99.9999 | 0.00 | 0.00 | 5069.88 | 5069.88 | 0.31143798 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 37.05 | 20.85 | 0.00875166 | 59723.0 | |
| SPLIT GN2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5063.222 | 5063.222 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.263411 | 0.31704018 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 5063.22 | 5063.22 | 1.0000 | 0.31704018 | 0.263411 | 21.00 | 15.45 | 0.00866985 | 43124.4 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5063.22 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 9.8533 | 21.10 | 0.00800000 | 25.53 | 0.02075559 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5082.778 | 3995.551 | 0.260650 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.0086 | 1004.8586 | 1.2036 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.260650 | 0.31371667 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 4970.54 | 4122.75 | 0.9779 | 0.31371667 | 0.260650 | 25.71 | 17.60 | 0.00923565 | 49372.8 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 291.956 | 4678.58 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 9.9576 | 24.01 | 0.00836022 | 24.00 | 0.00836022 | 44.9944 | 3098.86 | 0.00 | 5081.91 | 3991.04 | 0.30132723 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.72 | 13.70 | 0.00976525 | 38457.3 | |
| SPLIT GS1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5082.778 | 5082.778 | 0.260650 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.260650 | 0.31371667 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 5082.78 | 5082.78 | 1.0000 | 0.31371667 | 0.260650 | 21.00 | 15.46 | 0.00867695 | 43141.3 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5082.78 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 9.9576 | 21.10 | 0.00800000 | 24.92 | 0.01479830 | 74.5978 | 0.00 | 0.00 | 5089.46 | 5089.46 | 0.30817320 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 37.28 | 20.92 | 0.00875166 | 59959.0 | |
| SPLIT GS1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5082.778 | 5082.778 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.260650 | 0.31371667 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 5082.78 | 5082.78 | 1.0000 | 0.31371667 | 0.260650 | 21.00 | 15.46 | 0.00867695 | 43141.3 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5082.78 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 9.9576 | 21.10 | 0.00800000 | 24.92 | 0.01479830 | 74.5978 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5124.921 | 4032.016 | 0.263359 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.9848 | 1004.8586 | 1.2036 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.263359 | 0.31697766 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 5010.17 | 4162.65 | 0.9776 | 0.31697766 | 0.263359 | 25.70 | 17.58 | 0.00922284 | 49333.0 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 294.991 | 4715.18 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 9.8552 | 24.02 | 0.00835600 | 24.00 | 0.00835600 | 44.9720 | 3130.18 | 0.00 | 5124.05 | 4027.80 | 0.30445944 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.73 | 13.71 | 0.00977293 | 38492.4 | |
| SPLIT GS2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5124.921 | 5124.921 | 0.263359 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.263359 | 0.31697766 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 5124.92 | 5124.92 | 1.0000 | 0.31697766 | 0.263359 | 21.00 | 15.45 | 0.00866999 | 43124.7 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5124.92 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 9.8552 | 21.10 | 0.00800000 | 24.68 | 0.01479830 | 75.6975 | 0.00 | 0.00 | 5131.66 | 5131.66 | 0.31137657 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 37.25 | 20.91 | 0.00875166 | 59924.6 | |
| SPLIT GS2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5124.921 | 5124.921 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.263359 | 0.31697766 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 5124.92 | 5124.92 | 1.0000 | 0.31697766 | 0.263359 | 21.00 | 15.45 | 0.00866999 | 43124.7 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5124.92 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 9.8552 | 21.10 | 0.00800000 | 24.68 | 0.01479830 | 75.6975 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 12843.655 | 10277.568 | 0.690522 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.4916 | 1004.8586 | 1.2036 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.690522 | 0.83110926 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 12472.05 | 10741.49 | 0.9711 | 0.83110926 | 0.690522 | 25.54 | 17.31 | 0.00895752 | 48494.4 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 773.460 | 11698.59 | 31.89 | 0.01715183 | 24.99 | 0.05190911 | 7.5174 | 24.04 | 0.00829145 | 24.00 | 0.00829145 | 44.6290 | 16296.36 | 0.00 | 12841.47 | 10266.48 | 0.79828673 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.10 | 13.99 | 0.00991996 | 39236.1 | |
| SPLIT MSW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 12843.655 | 12843.655 | 0.690522 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.690522 | 0.83110926 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 12843.65 | 12843.65 | 1.0000 | 0.83110926 | 0.690522 | 21.02 | 15.32 | 0.00851105 | 42744.9 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12843.65 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 7.5174 | 21.10 | 0.00800000 | 24.34 | 0.01479830 | 77.2665 | 0.00 | 0.00 | 12860.53 | 12860.53 | 0.81642330 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.54 | 20.69 | 0.00875166 | 59196.4 | |
| SPLIT MSW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 12843.655 | 12843.655 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.690522 | 0.83110926 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 12843.65 | 12843.65 | 1.0000 | 0.83110926 | 0.690522 | 21.02 | 15.32 | 0.00851105 | 42744.9 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12843.65 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 7.5174 | 21.10 | 0.00800000 | 24.34 | 0.01479830 | 77.2665 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 12898.907 | 10321.419 | 0.697672 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.4174 | 1004.8586 | 1.2036 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.697672 | 0.83971480 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 12514.91 | 10840.54 | 0.9702 | 0.83971480 | 0.697672 | 25.54 | 17.27 | 0.00891764 | 48387.4 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 781.468 | 11733.44 | 31.89 | 0.01715183 | 24.99 | 0.05190911 | 7.4403 | 24.04 | 0.00825574 | 24.00 | 0.00825574 | 44.4391 | 16460.70 | 0.00 | 12896.71 | 10311.97 | 0.80655241 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.17 | 14.03 | 0.00992818 | 39332.5 | |
| SPLIT MNW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 12898.907 | 12898.907 | 0.697672 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.697672 | 0.83971480 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 12898.91 | 12898.91 | 1.0000 | 0.83971480 | 0.697672 | 21.03 | 15.31 | 0.00850582 | 42732.3 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12898.91 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 7.4403 | 21.10 | 0.00800000 | 25.00 | 0.02010062 | 99.9999 | 0.00 | 0.00 | 12915.86 | 12915.86 | 0.82487678 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.45 | 20.67 | 0.00875166 | 59102.0 | |
| SPLIT MNW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 12898.907 | 12898.907 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.697672 | 0.83971480 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 12898.91 | 12898.91 | 1.0000 | 0.83971480 | 0.697672 | 21.03 | 15.31 | 0.00850582 | 42732.3 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12898.91 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 7.4403 | 21.10 | 0.00800000 | 25.00 | 0.02010062 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 12146.232 | 9717.126 | 0.642660 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.6743 | 1004.8586 | 1.2036 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.642660 | 0.77350211 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 11822.39 | 10042.89 | 0.9733 | 0.77350211 | 0.642660 | 25.58 | 17.40 | 0.00905582 | 48784.9 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 719.848 | 11102.54 | 31.88 | 0.01715183 | 24.99 | 0.05190911 | 8.0772 | 24.04 | 0.00834443 | 24.00 | 0.00834443 | 44.9106 | 15194.98 | 0.00 | 12144.16 | 9693.11 | 0.74295463 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.92 | 13.89 | 0.00989117 | 38976.6 | |
| SPLIT MSE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 12146.232 | 12146.232 | 0.642660 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.642660 | 0.77350211 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 12146.23 | 12146.23 | 1.0000 | 0.77350211 | 0.642660 | 21.02 | 15.35 | 0.00854911 | 42835.8 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12146.23 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 8.0772 | 21.10 | 0.00800000 | 24.34 | 0.01479830 | 77.2665 | 0.00 | 0.00 | 12162.19 | 12162.19 | 0.75983409 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.79 | 20.77 | 0.00875166 | 59450.5 | |
| SPLIT MSE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 12146.232 | 12146.232 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.642660 | 0.77350211 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 12146.23 | 12146.23 | 1.0000 | 0.77350211 | 0.642660 | 21.02 | 15.35 | 0.00854911 | 42835.8 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12146.23 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 8.0772 | 21.10 | 0.00800000 | 24.34 | 0.01479830 | 77.2665 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 12183.913 | 9754.359 | 0.649822 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.5727 | 1004.8586 | 1.2036 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.649822 | 0.78212233 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 11845.31 | 10140.83 | 0.9722 | 0.78212233 | 0.649822 | 25.58 | 17.36 | 0.00900117 | 48639.9 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 727.871 | 11117.44 | 31.89 | 0.01715183 | 24.99 | 0.05190911 | 7.9882 | 24.04 | 0.00829356 | 24.00 | 0.00829356 | 44.6401 | 15361.40 | 0.00 | 12181.84 | 9745.71 | 0.75123441 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.99 | 13.94 | 0.00991322 | 39106.6 | |
| SPLIT MNE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 12183.913 | 12183.913 | 0.649822 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.649822 | 0.78212233 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 12183.91 | 12183.91 | 1.0000 | 0.78212233 | 0.649822 | 21.02 | 15.34 | 0.00854306 | 42821.4 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12183.91 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 7.9882 | 21.10 | 0.00800000 | 25.00 | 0.02010062 | 99.9999 | 0.00 | 0.00 | 12199.92 | 12199.92 | 0.76830199 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.66 | 20.73 | 0.00875166 | 59323.2 | |
| SPLIT MNE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 12183.913 | 12183.913 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.649822 | 0.78212233 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 12183.91 | 12183.91 | 1.0000 | 0.78212233 | 0.649822 | 21.02 | 15.34 | 0.00854306 | 42821.4 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12183.91 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 7.9882 | 21.10 | 0.00800000 | 25.00 | 0.02010062 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 10992.238 | 8762.081 | 0.578177 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.7103 | 1004.8586 | 1.2036 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.578177 | 0.69589060 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 10708.80 | 9077.42 | 0.9742 | 0.69589060 | 0.578177 | 25.64 | 17.44 | 0.00907519 | 48896.0 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 647.620 | 10061.18 | 31.89 | 0.01715183 | 24.99 | 0.05190911 | 8.9781 | 24.03 | 0.00827854 | 24.00 | 0.00827854 | 44.5601 | 13703.14 | 0.00 | 10990.37 | 8753.45 | 0.66840819 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.87 | 13.86 | 0.00987252 | 38879.8 | |
| SPLIT MN1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 10992.238 | 10992.238 | 0.578177 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.578177 | 0.69589060 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 10992.24 | 10992.24 | 1.0000 | 0.69589060 | 0.578177 | 21.01 | 15.40 | 0.00861036 | 42982.2 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10992.24 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 8.9781 | 21.10 | 0.00800000 | 25.86 | 0.02118516 | 99.9999 | 0.00 | 0.00 | 11006.68 | 11006.68 | 0.68359400 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.88 | 20.80 | 0.00875166 | 59545.3 | |
| SPLIT MN1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10992.238 | 10992.238 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.578177 | 0.69589060 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 10992.24 | 10992.24 | 1.0000 | 0.69589060 | 0.578177 | 21.01 | 15.40 | 0.00861036 | 42982.2 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10992.24 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 8.9781 | 21.10 | 0.00800000 | 25.86 | 0.02118516 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 10978.765 | 8750.252 | 0.577289 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.7138 | 1004.8586 | 1.2036 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.577289 | 0.69482214 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 10696.17 | 9064.37 | 0.9743 | 0.69482214 | 0.577289 | 25.64 | 17.44 | 0.00907707 | 48901.7 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 646.626 | 10049.54 | 31.89 | 0.01715183 | 24.99 | 0.05190911 | 8.9919 | 24.03 | 0.00827926 | 24.00 | 0.00827926 | 44.5640 | 13682.67 | 0.00 | 10976.90 | 8741.53 | 0.66738192 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.87 | 13.85 | 0.00987141 | 38874.7 | |
| SPLIT MN2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 10978.765 | 10978.765 | 0.577289 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.577289 | 0.69482214 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 10978.77 | 10978.77 | 1.0000 | 0.69482214 | 0.577289 | 21.01 | 15.40 | 0.00861129 | 42984.4 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10978.77 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 8.9919 | 21.10 | 0.00800000 | 25.86 | 0.02118516 | 99.9999 | 0.00 | 0.00 | 10993.19 | 10993.19 | 0.68254442 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.88 | 20.80 | 0.00875166 | 59550.3 | |
| SPLIT MN2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10978.765 | 10978.765 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.577289 | 0.69482214 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 10978.77 | 10978.77 | 1.0000 | 0.69482214 | 0.577289 | 21.01 | 15.40 | 0.00861129 | 42984.4 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10978.77 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 8.9919 | 21.10 | 0.00800000 | 25.86 | 0.02118516 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 11000.750 | 8700.793 | 0.571054 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.8830 | 1004.8586 | 1.2036 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.571054 | 0.68731808 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 10737.91 | 8984.52 | 0.9761 | 0.68731808 | 0.571054 | 25.65 | 17.52 | 0.00916810 | 49140.1 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 639.642 | 10098.27 | 31.89 | 0.01715183 | 24.99 | 0.05190911 | 9.0900 | 24.02 | 0.00836981 | 24.00 | 0.00836981 | 45.0454 | 13538.76 | 0.00 | 10998.88 | 8691.39 | 0.66017421 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.80 | 13.78 | 0.00981424 | 38661.8 | |
| SPLIT MS1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 11000.750 | 11000.750 | 0.571054 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.571054 | 0.68731808 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 11000.75 | 11000.75 | 1.0000 | 0.68731808 | 0.571054 | 21.01 | 15.41 | 0.00861797 | 43000.4 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11000.75 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 9.0900 | 21.10 | 0.00800000 | 25.14 | 0.01479830 | 73.6243 | 0.00 | 0.00 | 11015.21 | 11015.21 | 0.67517296 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 37.09 | 20.86 | 0.00875166 | 59758.7 | |
| SPLIT MS1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 11000.750 | 11000.750 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.571054 | 0.68731808 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 11000.75 | 11000.75 | 1.0000 | 0.68731808 | 0.571054 | 21.01 | 15.41 | 0.00861797 | 43000.4 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11000.75 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 9.0900 | 21.10 | 0.00800000 | 25.14 | 0.01479830 | 73.6243 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 10987.566 | 8689.101 | 0.570162 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.8873 | 1004.8586 | 1.2036 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.570162 | 0.68624433 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 10725.63 | 8971.44 | 0.9762 | 0.68624433 | 0.570162 | 25.65 | 17.52 | 0.00917041 | 49146.9 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 638.643 | 10086.98 | 31.89 | 0.01715183 | 24.99 | 0.05190911 | 9.1043 | 24.02 | 0.00837097 | 24.00 | 0.00837097 | 45.0516 | 13518.21 | 0.00 | 10985.70 | 8679.58 | 0.65914287 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.80 | 13.77 | 0.00981292 | 38655.7 | |
| SPLIT MS2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 10987.566 | 10987.566 | 0.570162 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.570162 | 0.68624433 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 10987.57 | 10987.57 | 1.0000 | 0.68624433 | 0.570162 | 21.01 | 15.41 | 0.00861894 | 43002.7 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10987.57 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 9.1043 | 21.10 | 0.00800000 | 25.14 | 0.01479830 | 73.6243 | 0.00 | 0.00 | 11002.01 | 11002.01 | 0.67411818 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 37.09 | 20.86 | 0.00875166 | 59764.7 | |
| SPLIT MS2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10987.566 | 10987.566 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.570162 | 0.68624433 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 10987.57 | 10987.57 | 1.0000 | 0.68624433 | 0.570162 | 21.01 | 15.41 | 0.00861894 | 43002.7 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10987.57 | 20.10 | 0.01479830 | 20.10 | 0.05190911 | 9.1043 | 21.10 | 0.00800000 | 25.14 | 0.01479830 | 73.6243 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6855.572 | 5490.597 | 0.371611 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.4094 | 1004.8586 | 1.2036 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.371611 | 0.44726875 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 6649.30 | 5761.86 | 0.9699 | 0.44726875 | 0.371611 | 25.51 | 17.26 | 0.00891332 | 48347.5 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 416.244 | 6233.06 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 6.9843 | 24.05 | 0.00829471 | 24.00 | 0.00829471 | 44.6464 | 4378.93 | 0.00 | 6854.41 | 5483.56 | 0.42960501 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.19 | 14.04 | 0.00993357 | 39367.3 | |
| SPLIT TSW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 6855.572 | 6855.572 | 0.371611 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.371611 | 0.44726875 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 6855.57 | 6855.57 | 1.0000 | 0.44726875 | 0.371611 | 21.03 | 15.29 | 0.00847482 | 42658.3 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6855.57 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 6.9843 | 21.10 | 0.00800000 | 22.53 | 0.01479830 | 86.1699 | 0.00 | 0.00 | 6864.58 | 6864.58 | 0.43936537 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.41 | 20.66 | 0.00875166 | 59068.0 | |
| SPLIT TSW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6855.572 | 6855.572 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.371611 | 0.44726875 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 6855.57 | 6855.57 | 1.0000 | 0.44726875 | 0.371611 | 21.03 | 15.29 | 0.00847482 | 42658.3 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6855.57 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 6.9843 | 21.10 | 0.00800000 | 22.53 | 0.01479830 | 86.1699 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6925.227 | 5544.262 | 0.377314 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.3489 | 1004.8586 | 1.2036 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.377314 | 0.45413287 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 6711.94 | 5843.59 | 0.9692 | 0.45413287 | 0.377314 | 25.50 | 17.23 | 0.00888076 | 48257.0 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 422.632 | 6289.31 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 6.8788 | 24.05 | 0.00826978 | 24.00 | 0.00826978 | 44.5138 | 4444.76 | 0.00 | 6924.05 | 5537.85 | 0.43619805 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.26 | 14.07 | 0.00993867 | 39448.8 | |
| SPLIT TNW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 6925.227 | 6925.227 | 0.377314 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.377314 | 0.45413287 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 6925.23 | 6925.23 | 1.0000 | 0.45413287 | 0.377314 | 21.03 | 15.28 | 0.00846764 | 42641.1 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6925.23 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 6.8788 | 21.10 | 0.00800000 | 23.26 | 0.01804278 | 99.9999 | 0.00 | 0.00 | 6934.33 | 6934.33 | 0.44610820 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.33 | 20.63 | 0.00875166 | 58988.1 | |
| SPLIT TNW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6925.227 | 6925.227 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.377314 | 0.45413287 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 6925.23 | 6925.23 | 1.0000 | 0.45413287 | 0.377314 | 21.03 | 15.28 | 0.00846764 | 42641.1 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6925.23 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 6.8788 | 21.10 | 0.00800000 | 23.26 | 0.01804278 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6343.608 | 5076.013 | 0.337899 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.6020 | 1004.8586 | 1.2036 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.337899 | 0.40669390 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 6168.38 | 5267.94 | 0.9724 | 0.40669390 | 0.337899 | 25.56 | 17.36 | 0.00901694 | 48662.1 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 378.484 | 5789.90 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 7.6812 | 24.05 | 0.00834010 | 24.00 | 0.00834010 | 44.8876 | 3990.58 | 0.00 | 6342.53 | 5071.28 | 0.39063256 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.98 | 13.93 | 0.00990871 | 39085.8 | |
| SPLIT TSE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 6343.608 | 6343.608 | 0.337899 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.337899 | 0.40669390 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 6343.61 | 6343.61 | 1.0000 | 0.40669390 | 0.337899 | 21.02 | 15.33 | 0.00852219 | 42771.5 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6343.61 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 7.6812 | 21.10 | 0.00800000 | 22.53 | 0.01479830 | 86.1699 | 0.00 | 0.00 | 6351.94 | 6351.94 | 0.39950749 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.68 | 20.74 | 0.00875166 | 59343.5 | |
| SPLIT TSE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6343.608 | 6343.608 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.337899 | 0.40669390 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 6343.61 | 6343.61 | 1.0000 | 0.40669390 | 0.337899 | 21.02 | 15.33 | 0.00852219 | 42771.5 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6343.61 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 7.6812 | 21.10 | 0.00800000 | 22.53 | 0.01479830 | 86.1699 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6408.419 | 5128.672 | 0.343589 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.5227 | 1004.8586 | 1.2036 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.343589 | 0.41354180 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 6225.50 | 5349.03 | 0.9715 | 0.41354180 | 0.343589 | 25.55 | 17.33 | 0.00897428 | 48544.2 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 384.857 | 5840.65 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 7.5540 | 24.05 | 0.00830608 | 24.00 | 0.00830608 | 44.7067 | 4056.06 | 0.00 | 6407.33 | 5122.74 | 0.39721002 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.06 | 13.97 | 0.00991667 | 39191.6 | |
| SPLIT TNE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 6408.419 | 6408.419 | 0.343589 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.343589 | 0.41354180 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 6408.42 | 6408.42 | 1.0000 | 0.41354180 | 0.343589 | 21.02 | 15.32 | 0.00851354 | 42750.8 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6408.42 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 7.5540 | 21.10 | 0.00800000 | 23.26 | 0.01804278 | 99.9999 | 0.00 | 0.00 | 6416.84 | 6416.84 | 0.40623439 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.58 | 20.71 | 0.00875166 | 59240.0 | |
| SPLIT TNE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6408.419 | 6408.419 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.343589 | 0.41354180 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 6408.42 | 6408.42 | 1.0000 | 0.41354180 | 0.343589 | 21.02 | 15.32 | 0.00851354 | 42750.8 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6408.42 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 7.5540 | 21.10 | 0.00800000 | 23.26 | 0.01804278 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5953.579 | 4767.222 | 0.318645 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.5149 | 1004.8586 | 1.2036 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.318645 | 0.38351917 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 5785.26 | 4975.80 | 0.9717 | 0.38351917 | 0.318645 | 25.59 | 17.34 | 0.00897008 | 48577.7 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 356.916 | 5428.35 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 8.1453 | 24.04 | 0.00824456 | 24.00 | 0.00824456 | 44.3795 | 3769.55 | 0.00 | 5952.57 | 4761.49 | 0.36837306 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.03 | 13.96 | 0.00991694 | 39163.3 | |
| SPLIT TN1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5953.579 | 5953.579 | 0.318645 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.318645 | 0.38351917 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 5953.58 | 5953.58 | 1.0000 | 0.38351917 | 0.318645 | 21.02 | 15.35 | 0.00855374 | 42846.9 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5953.58 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 8.1453 | 21.10 | 0.00800000 | 23.94 | 0.01882666 | 99.9999 | 0.00 | 0.00 | 5961.40 | 5961.40 | 0.37674227 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.61 | 20.71 | 0.00875166 | 59267.7 | |
| SPLIT TN1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5953.579 | 5953.579 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.318645 | 0.38351917 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 5953.58 | 5953.58 | 1.0000 | 0.38351917 | 0.318645 | 21.02 | 15.35 | 0.00855374 | 42846.9 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5953.58 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 8.1453 | 21.10 | 0.00800000 | 23.94 | 0.01882666 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5934.898 | 4750.918 | 0.317424 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.5224 | 1004.8586 | 1.2036 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.317424 | 0.38204983 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 5767.70 | 4957.91 | 0.9718 | 0.38204983 | 0.317424 | 25.60 | 17.34 | 0.00897412 | 48590.4 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 355.549 | 5412.15 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 8.1766 | 24.04 | 0.00824592 | 24.00 | 0.00824592 | 44.3867 | 3755.54 | 0.00 | 5933.89 | 4745.09 | 0.36696175 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.03 | 13.96 | 0.00991450 | 39152.1 | |
| SPLIT TN2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5934.898 | 5934.898 | 0.317424 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.317424 | 0.38204983 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 5934.90 | 5934.90 | 1.0000 | 0.38204983 | 0.317424 | 21.02 | 15.35 | 0.00855587 | 42852.0 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5934.90 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 8.1766 | 21.10 | 0.00800000 | 23.94 | 0.01882666 | 99.9999 | 0.00 | 0.00 | 5942.70 | 5942.70 | 0.37529890 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.62 | 20.72 | 0.00875166 | 59278.7 | |
| SPLIT TN2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5934.898 | 5934.898 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.317424 | 0.38204983 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 5934.90 | 5934.90 | 1.0000 | 0.38204983 | 0.317424 | 21.02 | 15.35 | 0.00855587 | 42852.0 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5934.90 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 8.1766 | 21.10 | 0.00800000 | 23.94 | 0.01882666 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5893.408 | 4715.507 | 0.312907 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.6128 | 1004.8586 | 1.2036 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.312907 | 0.37661315 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 5733.47 | 4894.60 | 0.9729 | 0.37661315 | 0.312907 | 25.60 | 17.38 | 0.00902273 | 48722.8 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 350.489 | 5382.98 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 8.2947 | 24.04 | 0.00828746 | 24.00 | 0.00828746 | 44.6076 | 3703.66 | 0.00 | 5892.40 | 4710.62 | 0.36173978 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.94 | 13.91 | 0.00990376 | 39033.3 | |
| SPLIT TS1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5893.408 | 5893.408 | 0.312907 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.312907 | 0.37661315 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 5893.41 | 5893.41 | 1.0000 | 0.37661315 | 0.312907 | 21.02 | 15.36 | 0.00856390 | 42871.2 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5893.41 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 8.2947 | 21.10 | 0.00800000 | 23.14 | 0.01479830 | 83.0225 | 0.00 | 0.00 | 5901.15 | 5901.15 | 0.36995828 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.73 | 20.75 | 0.00875166 | 59395.0 | |
| SPLIT TS1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5893.408 | 5893.408 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.312907 | 0.37661315 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 5893.41 | 5893.41 | 1.0000 | 0.37661315 | 0.312907 | 21.02 | 15.36 | 0.00856390 | 42871.2 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5893.41 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 8.2947 | 21.10 | 0.00800000 | 23.14 | 0.01479830 | 83.0225 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5874.939 | 4705.126 | 0.311683 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.6214 | 1004.8586 | 1.2036 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.311683 | 0.37514065 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 19:00:00 | Sensible | 5716.15 | 4876.69 | 0.9730 | 0.37514065 | 0.311683 | 25.61 | 17.39 | 0.00902737 | 48737.1 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 349.119 | 5367.03 | 31.89 | 0.01715183 | 24.99 | 0.02595455 | 8.3272 | 24.04 | 0.00828937 | 24.00 | 0.00828937 | 44.6178 | 3689.63 | 0.00 | 5873.94 | 4700.21 | 0.36032543 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.92 | 13.91 | 0.00990750 | 39020.6 | |
| SPLIT TS2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5874.939 | 5874.939 | 0.311683 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.311683 | 0.37514065 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 5874.94 | 5874.94 | 1.0000 | 0.37514065 | 0.311683 | 21.02 | 15.36 | 0.00856611 | 42876.4 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5874.94 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 8.3272 | 21.10 | 0.00800000 | 23.14 | 0.01479830 | 83.0225 | 0.00 | 0.00 | 5882.66 | 5882.66 | 0.36851180 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.74 | 20.76 | 0.00875166 | 59407.4 | |
| SPLIT TS2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5874.939 | 5874.939 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.311683 | 0.37514065 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 5874.94 | 5874.94 | 1.0000 | 0.37514065 | 0.311683 | 21.02 | 15.36 | 0.00856611 | 42876.4 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5874.94 | 20.10 | 0.01479830 | 20.10 | 0.02595455 | 8.3272 | 21.10 | 0.00800000 | 23.14 | 0.01479830 | 83.0225 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
Economizer| High Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
| None |
| Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
| None |
| Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
| G SW APARTMENT | 6145.00 | 638.33 | 638.33 |
| G NW APARTMENT | 8760.00 | 619.17 | 619.17 |
| OFFICE | 1750.00 | 34.50 | 34.50 |
| G NE APARTMENT | 8760.00 | 615.17 | 615.17 |
| G N1 APARTMENT | 8760.00 | 1050.00 | 1050.00 |
| G N2 APARTMENT | 8760.00 | 1045.33 | 1045.33 |
| G S1 APARTMENT | 6145.00 | 850.00 | 850.00 |
| G S2 APARTMENT | 6145.00 | 386.67 | 386.67 |
| M SW APARTMENT | 6145.00 | 1445.50 | 1445.50 |
| M NW APARTMENT | 8760.00 | 1720.50 | 1720.50 |
| M SE APARTMENT | 6145.00 | 1461.00 | 1461.00 |
| M NE APARTMENT | 8760.00 | 1699.00 | 1699.00 |
| M N1 APARTMENT | 8760.00 | 2310.33 | 2310.33 |
| M N2 APARTMENT | 8760.00 | 2305.17 | 2305.17 |
| M S1 APARTMENT | 6145.00 | 1783.33 | 1783.33 |
| M S2 APARTMENT | 6145.00 | 1783.17 | 1783.17 |
| T SW APARTMENT | 6143.00 | 2316.50 | 2316.50 |
| T NW APARTMENT | 8757.67 | 2737.50 | 2737.50 |
| T SE APARTMENT | 6143.00 | 2378.17 | 2378.17 |
| T NE APARTMENT | 8757.83 | 2673.50 | 2673.50 |
| T N1 APARTMENT | 8760.00 | 2898.83 | 2898.83 |
| T N2 APARTMENT | 8760.00 | 2893.67 | 2893.67 |
| T S1 APARTMENT | 6145.00 | 2426.83 | 2426.83 |
| T S2 APARTMENT | 6145.00 | 2449.83 | 2449.83 |
| T CORRIDOR | 8760.00 | 8760.00 | 8760.00 |
| G CORRIDOR | 8760.00 | 8757.33 | 8757.33 |
| M CORRIDOR | 8760.00 | 8760.00 | 8760.00 |
| Facility | 8760.00 | 8760.00 | 8760.00 |
| During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
| G SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 0.00 | 74.00 | 0.00 | 0.00 |
| G NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| Facility | 0.00 | 74.00 | 0.00 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
Average Outdoor Air During Occupied Hours| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| G SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.360 | 0.025 | 0.000 | 0.004 |
| G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.028 | 0.000 | 0.004 |
| OFFICE | 4.75 | 4.75 | 268.97 | 0.527 | 0.032 | 0.000 | 0.000 |
| G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.028 | 0.000 | 0.003 |
| G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.017 | 0.000 | 0.004 |
| G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.017 | 0.000 | 0.004 |
| G S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.360 | 0.015 | 0.000 | 0.004 |
| G S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.359 | 0.015 | 0.000 | 0.004 |
| M SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.360 | 0.037 | 0.000 | 0.006 |
| M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.040 | 0.000 | 0.005 |
| M SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.360 | 0.037 | 0.000 | 0.006 |
| M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.040 | 0.000 | 0.005 |
| M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.024 | 0.000 | 0.006 |
| M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.024 | 0.000 | 0.006 |
| M S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.360 | 0.022 | 0.000 | 0.006 |
| M S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.360 | 0.022 | 0.000 | 0.006 |
| T SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.360 | 0.048 | 0.000 | 0.007 |
| T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.053 | 0.000 | 0.006 |
| T SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.360 | 0.048 | 0.000 | 0.006 |
| T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.053 | 0.000 | 0.005 |
| T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.032 | 0.000 | 0.006 |
| T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.032 | 0.000 | 0.006 |
| T S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.360 | 0.029 | 0.000 | 0.007 |
| T S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.360 | 0.029 | 0.000 | 0.007 |
| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| G SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.000 | 0.000 | 0.000 |
| OFFICE | 4.75 | 4.75 | 268.97 | 0.516 | 0.000 | 0.000 | 0.000 |
| G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.000 | 0.000 | 0.000 |
| G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.000 | 0.000 | 0.000 |
| G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.000 | 0.000 | 0.000 |
| G S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| G S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| M SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.353 | 0.000 | 0.000 | 0.000 |
| M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.000 | 0.000 | 0.000 |
| M SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.000 | 0.000 | 0.000 |
| M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.000 | 0.000 | 0.000 |
| M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.000 | 0.000 | 0.000 |
| M S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.353 | 0.000 | 0.000 | 0.000 |
| M S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.353 | 0.000 | 0.000 | 0.000 |
| T SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.353 | 0.000 | 0.000 | 0.000 |
| T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
| T SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.353 | 0.000 | 0.000 | 0.000 |
| T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.000 | 0.000 | 0.000 |
| T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.000 | 0.000 | 0.000 |
| T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.000 | 0.000 | 0.000 |
| T S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.353 | 0.000 | 0.000 | 0.000 |
| T S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.353 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
Mechanical Ventilation Parameters by Zone| AirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
| G SW APARTMENT | SPLIT GSW | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G NW APARTMENT | SPLIT GNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| OFFICE | SPLIT OFFICE | 4.75 | 4.75 | 268.97 | 88.25 | 0.0381 | 0.038 |
| G NE APARTMENT | SPLIT GNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G N1 APARTMENT | SPLIT GN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G N2 APARTMENT | SPLIT GN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G S1 APARTMENT | SPLIT GS1 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G S2 APARTMENT | SPLIT GS2 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| M SW APARTMENT | SPLIT MSW | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M NW APARTMENT | SPLIT MNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M SE APARTMENT | SPLIT MSE | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M NE APARTMENT | SPLIT MNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M N1 APARTMENT | SPLIT MN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M N2 APARTMENT | SPLIT MN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M S1 APARTMENT | SPLIT MS1 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M S2 APARTMENT | SPLIT MS2 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| T SW APARTMENT | SPLIT TSW | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T NW APARTMENT | SPLIT TNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T SE APARTMENT | SPLIT TSE | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T NE APARTMENT | SPLIT TNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T N1 APARTMENT | SPLIT TN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T N2 APARTMENT | SPLIT TN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T S1 APARTMENT | SPLIT TS1 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T S2 APARTMENT | SPLIT TS2 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| Total Facility | 68.19 | 82.25 | 8607.06 | 2823.98 | 0.8427 | 1.258 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| G SW APARTMENT | 818502.78 | 7360.30 | 825863.08 | 62973.06 | 888836.15 | 818502.78 | 0.00 | 8628.60 | 131.40 | 2615.00 |
| G NW APARTMENT | 818502.78 | 8783.02 | 827285.80 | 62973.06 | 890258.87 | 818502.78 | 0.00 | 8609.64 | 150.36 | 0.00 |
| OFFICE | 1176565.59 | 0.00 | 1176565.59 | 62973.06 | 1239538.66 | 1201711.97 | 500.00 | 8260.00 | 0.00 | 7010.00 |
| G NE APARTMENT | 818502.78 | 7821.33 | 826324.11 | 62973.06 | 889297.17 | 818502.78 | 0.00 | 8625.12 | 134.88 | 0.00 |
| G N1 APARTMENT | 818502.78 | 9123.83 | 827626.61 | 37983.75 | 865610.36 | 818502.78 | 0.00 | 8603.11 | 156.89 | 0.00 |
| G N2 APARTMENT | 818502.78 | 9121.67 | 827624.45 | 37983.75 | 865608.21 | 818502.78 | 0.00 | 8603.16 | 156.84 | 0.00 |
| G S1 APARTMENT | 818502.78 | 7577.07 | 826079.84 | 37983.75 | 864063.60 | 818502.78 | 0.00 | 8624.54 | 135.46 | 2615.00 |
| G S2 APARTMENT | 818502.78 | 6517.30 | 825020.08 | 37983.75 | 863003.83 | 818502.78 | 0.00 | 8642.50 | 117.50 | 2615.00 |
| M SW APARTMENT | 1637005.55 | 10539.99 | 1647545.54 | 90496.84 | 1738042.37 | 1637005.55 | 0.00 | 8583.76 | 176.24 | 2615.00 |
| M NW APARTMENT | 1637005.55 | 12327.01 | 1649332.56 | 90496.84 | 1739829.40 | 1637005.55 | 0.00 | 8563.68 | 196.32 | 0.00 |
| M SE APARTMENT | 1637005.55 | 9451.20 | 1646456.76 | 90496.84 | 1736953.59 | 1637005.55 | 0.00 | 8601.81 | 158.19 | 2615.00 |
| M NE APARTMENT | 1637005.55 | 11234.34 | 1648239.90 | 90496.84 | 1738736.73 | 1637005.55 | 0.00 | 8582.51 | 177.49 | 0.00 |
| M N1 APARTMENT | 1637005.55 | 12812.88 | 1649818.44 | 54585.39 | 1704403.83 | 1637005.55 | 0.00 | 8556.85 | 203.15 | 0.00 |
| M N2 APARTMENT | 1637005.55 | 12784.60 | 1649790.16 | 54585.39 | 1704375.55 | 1637005.55 | 0.00 | 8557.32 | 202.68 | 0.00 |
| M S1 APARTMENT | 1637005.55 | 10765.67 | 1647771.22 | 54585.39 | 1702356.61 | 1637005.55 | 0.00 | 8580.98 | 179.02 | 2615.00 |
| M S2 APARTMENT | 1637005.55 | 10745.56 | 1647751.12 | 54585.39 | 1702336.51 | 1637005.55 | 0.00 | 8581.32 | 178.68 | 2615.00 |
| T SW APARTMENT | 818502.78 | 11902.69 | 830405.46 | 119707.90 | 950113.36 | 818502.78 | 0.00 | 8572.82 | 187.18 | 2615.00 |
| T NW APARTMENT | 818502.78 | 13427.43 | 831930.21 | 119707.90 | 951638.11 | 818502.78 | 0.00 | 8563.70 | 196.30 | 0.00 |
| T SE APARTMENT | 818502.78 | 10743.85 | 829246.63 | 119707.90 | 948954.53 | 818502.78 | 0.00 | 8592.26 | 167.74 | 2615.00 |
| T NE APARTMENT | 818502.78 | 12476.98 | 830979.75 | 119707.90 | 950687.65 | 818502.78 | 0.00 | 8579.85 | 180.15 | 0.00 |
| T N1 APARTMENT | 818502.78 | 13595.70 | 832098.47 | 72204.77 | 904303.24 | 818502.78 | 0.00 | 8563.77 | 196.23 | 0.00 |
| T N2 APARTMENT | 818502.78 | 13565.83 | 832068.60 | 72204.77 | 904273.37 | 818502.78 | 0.00 | 8564.18 | 195.82 | 0.00 |
| T S1 APARTMENT | 818502.78 | 11733.26 | 830236.04 | 72204.77 | 902440.81 | 818502.78 | 0.00 | 8577.45 | 182.55 | 2615.00 |
| T S2 APARTMENT | 818502.78 | 11723.11 | 830225.88 | 72204.77 | 902430.65 | 818502.78 | 0.00 | 8577.65 | 182.35 | 2615.00 |
| Total Facility | 39646196.12 | 336795.88 | 39982992.00 | 2332135.77 | 42315127.77 | 39671342.50 | 500.00 | 8759.67 | 213.68 | 8760.00 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
| G SW APARTMENT | 0.0260 | 0.0003 | 0.0263 | 0.0018 | 0.0281 | 0.0260 | 0.00 | 6020.06 | 124.94 |
| G NW APARTMENT | 0.0260 | 0.0003 | 0.0262 | 0.0020 | 0.0282 | 0.0260 | 0.00 | 8609.64 | 150.36 |
| OFFICE | 0.0381 | 0.0000 | 0.0381 | 0.0023 | 0.0404 | 0.0381 | 0.00 | 1750.00 | 0.00 |
| G NE APARTMENT | 0.0260 | 0.0002 | 0.0262 | 0.0020 | 0.0282 | 0.0260 | 0.00 | 8625.12 | 134.88 |
| G N1 APARTMENT | 0.0260 | 0.0003 | 0.0262 | 0.0012 | 0.0274 | 0.0260 | 0.00 | 8603.11 | 156.89 |
| G N2 APARTMENT | 0.0260 | 0.0003 | 0.0262 | 0.0012 | 0.0274 | 0.0260 | 0.00 | 8603.16 | 156.84 |
| G S1 APARTMENT | 0.0260 | 0.0003 | 0.0263 | 0.0011 | 0.0274 | 0.0260 | 0.00 | 6016.55 | 128.45 |
| G S2 APARTMENT | 0.0260 | 0.0003 | 0.0262 | 0.0011 | 0.0273 | 0.0260 | 0.00 | 6032.58 | 112.42 |
| M SW APARTMENT | 0.0519 | 0.0004 | 0.0524 | 0.0026 | 0.0550 | 0.0519 | 0.00 | 5979.08 | 165.92 |
| M NW APARTMENT | 0.0519 | 0.0004 | 0.0523 | 0.0029 | 0.0552 | 0.0519 | 0.00 | 8563.68 | 196.32 |
| M SE APARTMENT | 0.0519 | 0.0004 | 0.0523 | 0.0026 | 0.0549 | 0.0519 | 0.00 | 5993.74 | 151.26 |
| M NE APARTMENT | 0.0519 | 0.0004 | 0.0523 | 0.0029 | 0.0551 | 0.0519 | 0.00 | 8582.51 | 177.49 |
| M N1 APARTMENT | 0.0519 | 0.0004 | 0.0523 | 0.0017 | 0.0540 | 0.0519 | 0.00 | 8556.85 | 203.15 |
| M N2 APARTMENT | 0.0519 | 0.0004 | 0.0523 | 0.0017 | 0.0540 | 0.0519 | 0.00 | 8557.32 | 202.68 |
| M S1 APARTMENT | 0.0519 | 0.0005 | 0.0524 | 0.0016 | 0.0540 | 0.0519 | 0.00 | 5975.91 | 169.09 |
| M S2 APARTMENT | 0.0519 | 0.0005 | 0.0524 | 0.0016 | 0.0540 | 0.0519 | 0.00 | 5976.19 | 168.81 |
| T SW APARTMENT | 0.0260 | 0.0005 | 0.0264 | 0.0035 | 0.0299 | 0.0260 | 0.00 | 5969.50 | 175.50 |
| T NW APARTMENT | 0.0260 | 0.0004 | 0.0264 | 0.0038 | 0.0302 | 0.0260 | 0.00 | 8563.70 | 196.30 |
| T SE APARTMENT | 0.0260 | 0.0005 | 0.0264 | 0.0035 | 0.0299 | 0.0260 | 0.00 | 5985.09 | 159.91 |
| T NE APARTMENT | 0.0260 | 0.0004 | 0.0264 | 0.0038 | 0.0301 | 0.0260 | 0.00 | 8579.85 | 180.15 |
| T N1 APARTMENT | 0.0260 | 0.0004 | 0.0264 | 0.0023 | 0.0287 | 0.0260 | 0.00 | 8563.77 | 196.23 |
| T N2 APARTMENT | 0.0260 | 0.0004 | 0.0264 | 0.0023 | 0.0287 | 0.0260 | 0.00 | 8564.18 | 195.82 |
| T S1 APARTMENT | 0.0260 | 0.0005 | 0.0264 | 0.0021 | 0.0285 | 0.0260 | 0.00 | 5972.90 | 172.10 |
| T S2 APARTMENT | 0.0260 | 0.0005 | 0.0264 | 0.0021 | 0.0285 | 0.0260 | 0.00 | 5973.09 | 171.91 |
| Total Facility | 1.2580 | 0.0123 | 1.2702 | 0.0714 | 1.3416 | 1.2580 | 500.00 | 8759.67 | 213.68 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| SPLIT GSW | 0.00 | 7360.30 | 7360.30 | 818502.78 | 8757.11 | 0.99 | 1.90 | 6.46 |
| SPLIT GNW | 0.00 | 8783.02 | 8783.02 | 818502.78 | 8756.75 | 0.90 | 2.35 | 0.00 |
| SPLIT OFFICE | 1704421.01 | 0.00 | 1704421.01 | 1201711.97 | 380.00 | 22.83 | 8357.17 | 7010.00 |
| SPLIT GNE | 0.00 | 7821.33 | 7821.33 | 818502.78 | 8756.25 | 0.82 | 2.93 | 0.00 |
| SPLIT GN1 | 0.00 | 9123.83 | 9123.83 | 818502.78 | 8756.58 | 0.93 | 2.49 | 0.00 |
| SPLIT GN2 | 0.00 | 9121.67 | 9121.67 | 818502.78 | 8756.58 | 0.93 | 2.49 | 0.00 |
| SPLIT GS1 | 0.00 | 7577.07 | 7577.07 | 818502.78 | 8757.19 | 0.90 | 1.90 | 7.01 |
| SPLIT GS2 | 0.00 | 6517.30 | 6517.30 | 818502.78 | 8757.28 | 0.76 | 1.96 | 5.08 |
| SPLIT MSW | 0.00 | 10539.99 | 10539.99 | 1637005.55 | 8760.00 | 0.00 | 0.00 | 10.32 |
| SPLIT MNW | 0.00 | 12327.01 | 12327.01 | 1637005.55 | 8759.83 | 0.00 | 0.17 | 0.00 |
| SPLIT MSE | 0.00 | 9451.20 | 9451.20 | 1637005.55 | 8760.00 | 0.00 | 0.00 | 6.93 |
| SPLIT MNE | 0.00 | 11234.34 | 11234.34 | 1637005.55 | 8759.83 | 0.00 | 0.17 | 0.00 |
| SPLIT MN1 | 0.00 | 12812.88 | 12812.88 | 1637005.55 | 8759.83 | 0.00 | 0.17 | 0.00 |
| SPLIT MN2 | 0.00 | 12784.60 | 12784.60 | 1637005.55 | 8759.83 | 0.00 | 0.17 | 0.00 |
| SPLIT MS1 | 0.00 | 10765.67 | 10765.67 | 1637005.55 | 8760.00 | 0.00 | 0.00 | 9.93 |
| SPLIT MS2 | 0.00 | 10745.56 | 10745.56 | 1637005.55 | 8760.00 | 0.00 | 0.00 | 9.88 |
| SPLIT TSW | 0.00 | 11902.69 | 11902.69 | 818502.78 | 8747.97 | 1.57 | 10.46 | 11.68 |
| SPLIT TNW | 0.00 | 13427.43 | 13427.43 | 818502.78 | 8740.01 | 2.14 | 17.85 | 0.00 |
| SPLIT TSE | 0.00 | 10743.85 | 10743.85 | 818502.78 | 8747.96 | 0.90 | 11.14 | 7.83 |
| SPLIT TNE | 0.00 | 12476.98 | 12476.98 | 818502.78 | 8739.91 | 2.05 | 18.05 | 0.00 |
| SPLIT TN1 | 0.00 | 13595.70 | 13595.70 | 818502.78 | 8738.25 | 2.39 | 19.36 | 0.00 |
| SPLIT TN2 | 0.00 | 13565.83 | 13565.83 | 818502.78 | 8738.43 | 2.26 | 19.30 | 0.00 |
| SPLIT TS1 | 0.00 | 11733.26 | 11733.26 | 818502.78 | 8747.23 | 0.64 | 12.12 | 10.44 |
| SPLIT TS2 | 0.00 | 11723.11 | 11723.11 | 818502.78 | 8747.23 | 0.47 | 12.29 | 10.44 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
| SPLIT GSW | 0.0000 | 0.0003 | 0.0003 | 0.0260 | 6142.86 | 0.61 | 1.53 |
| SPLIT GNW | 0.0000 | 0.0003 | 0.0003 | 0.0260 | 8756.75 | 0.90 | 2.35 |
| SPLIT OFFICE | 0.0552 | 0.0000 | 0.0552 | 0.0381 | 0.00 | 0.00 | 1750.00 |
| SPLIT GNE | 0.0000 | 0.0002 | 0.0002 | 0.0260 | 8756.25 | 0.82 | 2.93 |
| SPLIT GN1 | 0.0000 | 0.0003 | 0.0003 | 0.0260 | 8756.58 | 0.93 | 2.49 |
| SPLIT GN2 | 0.0000 | 0.0003 | 0.0003 | 0.0260 | 8756.58 | 0.93 | 2.49 |
| SPLIT GS1 | 0.0000 | 0.0003 | 0.0003 | 0.0260 | 6142.86 | 0.61 | 1.53 |
| SPLIT GS2 | 0.0000 | 0.0003 | 0.0003 | 0.0260 | 6142.69 | 0.72 | 1.58 |
| SPLIT MSW | 0.0000 | 0.0004 | 0.0004 | 0.0519 | 6145.00 | 0.00 | 0.00 |
| SPLIT MNW | 0.0000 | 0.0004 | 0.0004 | 0.0519 | 8759.83 | 0.00 | 0.17 |
| SPLIT MSE | 0.0000 | 0.0004 | 0.0004 | 0.0519 | 6145.00 | 0.00 | 0.00 |
| SPLIT MNE | 0.0000 | 0.0004 | 0.0004 | 0.0519 | 8759.83 | 0.00 | 0.17 |
| SPLIT MN1 | 0.0000 | 0.0004 | 0.0004 | 0.0519 | 8759.83 | 0.00 | 0.17 |
| SPLIT MN2 | 0.0000 | 0.0004 | 0.0004 | 0.0519 | 8759.83 | 0.00 | 0.17 |
| SPLIT MS1 | 0.0000 | 0.0005 | 0.0005 | 0.0519 | 6145.00 | 0.00 | 0.00 |
| SPLIT MS2 | 0.0000 | 0.0005 | 0.0005 | 0.0519 | 6145.00 | 0.00 | 0.00 |
| SPLIT TSW | 0.0000 | 0.0005 | 0.0005 | 0.0260 | 6135.73 | 0.82 | 8.44 |
| SPLIT TNW | 0.0000 | 0.0004 | 0.0004 | 0.0260 | 8740.01 | 2.14 | 17.85 |
| SPLIT TSE | 0.0000 | 0.0005 | 0.0005 | 0.0260 | 6135.05 | 0.74 | 9.21 |
| SPLIT TNE | 0.0000 | 0.0004 | 0.0004 | 0.0260 | 8739.91 | 2.05 | 18.05 |
| SPLIT TN1 | 0.0000 | 0.0004 | 0.0004 | 0.0260 | 8738.25 | 2.39 | 19.36 |
| SPLIT TN2 | 0.0000 | 0.0004 | 0.0004 | 0.0260 | 8738.43 | 2.26 | 19.30 |
| SPLIT TS1 | 0.0000 | 0.0005 | 0.0005 | 0.0260 | 6135.04 | 0.31 | 9.65 |
| SPLIT TS2 | 0.0000 | 0.0005 | 0.0005 | 0.0260 | 6135.04 | 0.31 | 9.65 |
| No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
| SPLIT GSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT OFFICE | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MSE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TSE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
| SPLIT GSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT OFFICE | 0.0552 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MSE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TSE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
Surfaces by Class| Total | Outdoors | |
| Wall | 126 | 42 |
| Floor | 27 | 9 |
| Roof | 27 | 9 |
| Internal Mass | 24 | 0 |
| Building Detached Shading | 0 | 0 |
| Fixed Detached Shading | 0 | 0 |
| Window | 39 | 39 |
| Door | 0 | 0 |
| Glass Door | 0 | 0 |
| Shading | 0 | 0 |
| Overhang | 0 | 0 |
| Fin | 0 | 0 |
| Tubular Daylighting Device Dome | 0 | 0 |
| Tubular Daylighting Device Diffuser | 0 | 0 |
| Count | |
| HVAC Air Loops | 24 |
| Conditioned Zones | 24 |
| Unconditioned Zones | 3 |
| Supply Plenums | 0 |
| Return Plenums | 0 |
| Count | |
| IDF Objects | 1588 |
| Defaulted Fields | 1666 |
| Fields with Defaults | 5801 |
| Autosized Fields | 648 |
| Autosizable Fields | 770 |
| Autocalculated Fields | 332 |
| Autocalculatable Fields | 509 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
Annual and Peak Values - Electricity| Electricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| Electricity:Facility | 1191.65 | 16828.42 | 01-JAN-07:00 | 61373.15 | 13-JUN-16:10 |
| Electricity:Building | 527.01 | 10157.12 | 01-JAN-03:10 | 25266.90 | 03-JAN-17:10 |
| Electricity:Zone:G SW APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| Electricity:SpaceType:GENERAL | 527.01 | 10157.12 | 01-JAN-03:10 | 25266.90 | 03-JAN-17:10 |
| InteriorLights:Electricity | 73.00 | 1491.31 | 01-JAN-00:10 | 4040.47 | 01-JAN-19:10 |
| InteriorLights:Electricity:Zone:G SW APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| InteriorLights:Electricity:SpaceType:GENERAL | 73.00 | 1491.31 | 01-JAN-00:10 | 4040.47 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity | 67.97 | 1461.31 | 01-JAN-00:10 | 3560.62 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G SW APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 67.97 | 1461.31 | 01-JAN-00:10 | 3560.62 | 01-JAN-19:10 |
| Electricity:Zone:G NW APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G NW APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G NW APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:OFFICE | 13.20 | 218.21 | 01-JAN-00:10 | 992.54 | 03-JAN-08:10 |
| InteriorLights:Electricity:Zone:OFFICE | 5.68 | 89.52 | 01-JAN-00:10 | 447.62 | 03-JAN-08:10 |
| LightsWired:InteriorLights:Electricity:Zone:OFFICE | 5.68 | 89.52 | 01-JAN-00:10 | 447.62 | 03-JAN-08:10 |
| Electricity:Zone:G NE APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G NE APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G NE APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:G N1 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G N1 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G N1 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:G N2 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G N2 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G N2 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:G S1 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G S1 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G S1 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:G S2 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G S2 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G S2 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:M SW APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M SW APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M SW APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:M NW APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M NW APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M NW APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:M SE APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M SE APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M SE APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:M NE APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M NE APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M NE APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:M N1 APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M N1 APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M N1 APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:M N2 APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M N2 APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M N2 APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:M S1 APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M S1 APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M S1 APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:M S2 APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M S2 APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M S2 APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:T SW APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T SW APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T SW APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:T NW APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T NW APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T NW APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:T SE APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T SE APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T SE APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:T NE APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T NE APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T NE APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:T N1 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T N1 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T N1 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:T N2 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T N2 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T N2 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:T S1 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T S1 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T S1 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:T S2 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T S2 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T S2 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:G CORRIDOR | 77.61 | 1911.10 | 01-JAN-00:10 | 4111.81 | 01-JAN-07:10 |
| InteriorLights:Electricity:Zone:G CORRIDOR | 9.71 | 307.95 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:G CORRIDOR | 9.71 | 307.95 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 |
| Electricity:Zone:M CORRIDOR | 19.42 | 615.89 | 01-JAN-00:10 | 615.89 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:M CORRIDOR | 19.42 | 615.89 | 01-JAN-00:10 | 615.89 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:M CORRIDOR | 19.42 | 615.89 | 01-JAN-00:10 | 615.89 | 01-JAN-00:10 |
| Electricity:Zone:T CORRIDOR | 9.71 | 307.95 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:T CORRIDOR | 9.71 | 307.95 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:T CORRIDOR | 9.71 | 307.95 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 |
| LightsPlugIn:InteriorLights:Electricity | 5.02 | 30.00 | 01-JAN-00:10 | 479.85 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G SW APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:SpaceType:GENERAL | 5.02 | 30.00 | 01-JAN-00:10 | 479.85 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G NW APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G NE APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G N1 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G N2 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G S1 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G S2 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M SW APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M NW APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M SE APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M NE APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M N1 APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M N2 APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M S1 APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M S2 APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T SW APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T NW APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T SE APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T NE APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T N1 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T N2 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T S1 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T S2 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| InteriorEquipment:Electricity | 454.01 | 8665.81 | 01-JAN-03:10 | 22246.15 | 03-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G CORRIDOR | 67.90 | 1603.15 | 01-JAN-00:10 | 3803.87 | 01-JAN-07:10 |
| InteriorEquipment:Electricity:SpaceType:GENERAL | 454.01 | 8665.81 | 01-JAN-03:10 | 22246.15 | 03-JAN-17:10 |
| ElevatorLift:InteriorEquipment:Electricity | 67.41 | 1600.00 | 01-JAN-00:10 | 3772.37 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity:Zone:G CORRIDOR | 67.41 | 1600.00 | 01-JAN-00:10 | 3772.37 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity:SpaceType:GENERAL | 67.41 | 1600.00 | 01-JAN-00:10 | 3772.37 | 01-JAN-07:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity | 0.49 | 3.15 | 01-JAN-00:10 | 31.50 | 01-JAN-07:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity:Zone:G CORRIDOR | 0.49 | 3.15 | 01-JAN-00:10 | 31.50 | 01-JAN-07:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity:SpaceType:GENERAL | 0.49 | 3.15 | 01-JAN-00:10 | 31.50 | 01-JAN-07:10 |
| InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity | 386.12 | 7062.66 | 01-JAN-03:10 | 18442.28 | 03-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 386.12 | 7062.66 | 01-JAN-03:10 | 18442.28 | 03-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:OFFICE | 7.52 | 128.69 | 01-JAN-00:10 | 544.92 | 03-JAN-08:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:OFFICE | 7.52 | 128.69 | 01-JAN-00:10 | 544.92 | 03-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| Fans:Electricity | 168.01 | 1629.07 | 04-AUG-13:50 | 8579.35 | 22-JAN-11:20 |
| Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityPurchased:Facility | 1191.65 | 16828.42 | 01-JAN-07:00 | 61373.15 | 13-JUN-16:10 |
| ElectricityPurchased:Plant | 1191.65 | 16828.42 | 01-JAN-07:00 | 61373.15 | 13-JUN-16:10 |
| Cogeneration:ElectricityPurchased | 1191.65 | 16828.42 | 01-JAN-07:00 | 61373.15 | 13-JUN-16:10 |
| General:Cogeneration:ElectricityPurchased | 1191.65 | 16828.42 | 01-JAN-07:00 | 61373.15 | 13-JUN-16:10 |
| ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityNet:Facility | 1191.65 | 16828.42 | 01-JAN-07:00 | 61373.15 | 13-JUN-16:10 |
| ElectricityNet:Plant | 1191.65 | 16828.42 | 01-JAN-07:00 | 61373.15 | 13-JUN-16:10 |
| Cogeneration:ElectricityNet | 1191.65 | 16828.42 | 01-JAN-07:00 | 61373.15 | 13-JUN-16:10 |
| General:Cogeneration:ElectricityNet | 1191.65 | 16828.42 | 01-JAN-07:00 | 61373.15 | 13-JUN-16:10 |
| Electricity:HVAC | 631.12 | 1853.60 | 01-JAN-07:20 | 37084.47 | 13-JUN-15:20 |
| HeatRecovery:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:HeatRecovery:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Fans:Electricity | 168.01 | 1629.07 | 04-AUG-13:50 | 8579.35 | 22-JAN-11:20 |
| Cooling:Electricity | 463.11 | 0.00 | 01-JAN-07:00 | 29029.57 | 13-JUN-15:10 |
| General:Cooling:Electricity | 463.11 | 0.00 | 01-JAN-07:00 | 29029.57 | 13-JUN-15:10 |
| Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ExteriorLights:Electricity | 33.06 | 0.00 | 01-JAN-06:20 | 2101.03 | 01-JAN-00:10 |
| General:ExteriorLights:Electricity | 33.06 | 0.00 | 01-JAN-06:20 | 2101.03 | 01-JAN-00:10 |
| Electricity:Plant | 0.46 | 14.49 | 01-JAN-00:10 | 14.49 | 01-JAN-07:00 |
| Pumps:Electricity | 0.46 | 14.49 | 01-JAN-00:10 | 14.49 | 01-JAN-07:00 |
| General:Pumps:Electricity | 0.46 | 14.49 | 01-JAN-00:10 | 14.49 | 01-JAN-07:00 |
| Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| NaturalGas:Facility | 297.14 | 0.00 | 01-JAN-02:40 | 18960.66 | 17-JAN-07:50 |
| NaturalGas:Plant | 297.14 | 0.00 | 01-JAN-02:40 | 18960.66 | 17-JAN-07:50 |
| WaterSystems:NaturalGas | 297.14 | 0.00 | 01-JAN-02:40 | 18960.66 | 17-JAN-07:50 |
| Water Heater:WaterSystems:NaturalGas | 297.14 | 0.00 | 01-JAN-02:40 | 18960.66 | 17-JAN-07:50 |
| Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| Water:Facility | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 03-JAN-07:20 |
| Water:Plant | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 03-JAN-07:20 |
| WaterSystems:Water | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 03-JAN-07:20 |
| WaterUse:WaterSystems:Water | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 03-JAN-07:20 |
| MainsWater:Facility | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 03-JAN-07:20 |
| MainsWater:Plant | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 03-JAN-07:20 |
| WaterSystems:MainsWater | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 03-JAN-07:20 |
| WaterUse:WaterSystems:MainsWater | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 03-JAN-07:20 |
| Water Heater:WaterSystems:Water | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Water Heater:WaterSystems:MainsWater | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
| Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| EnergyTransfer:Facility | 3428.53 | 7404.73 | 20-AUG-12:40 | 200095.43 | 22-JAN-11:20 |
| EnergyTransfer:Building | 1139.00 | 104.96 | 09-OCT-19:20 | 72124.74 | 31-JAN-11:00 |
| EnergyTransfer:Zone:G SW APARTMENT | 40.92 | 0.03 | 06-JAN-06:50 | 2473.15 | 16-JAN-16:10 |
| Heating:EnergyTransfer | 5.21 | 0.00 | 01-JAN-13:10 | 1119.17 | 14-APR-16:40 |
| Heating:EnergyTransfer:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 26.90 | 22-JAN-10:50 |
| General:Heating:EnergyTransfer | 5.21 | 0.00 | 01-JAN-13:10 | 1119.17 | 14-APR-16:40 |
| General:Heating:EnergyTransfer:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 26.90 | 22-JAN-10:50 |
| Cooling:EnergyTransfer | 1133.79 | 0.00 | 01-JAN-07:00 | 72016.74 | 31-JAN-11:00 |
| Cooling:EnergyTransfer:Zone:G SW APARTMENT | 40.92 | 0.00 | 01-JAN-07:00 | 2473.15 | 16-JAN-16:10 |
| General:Cooling:EnergyTransfer | 1133.79 | 0.00 | 01-JAN-07:00 | 72016.74 | 31-JAN-11:00 |
| General:Cooling:EnergyTransfer:Zone:G SW APARTMENT | 40.92 | 0.00 | 01-JAN-07:00 | 2473.15 | 16-JAN-16:10 |
| EnergyTransfer:Zone:G NW APARTMENT | 39.10 | 0.03 | 30-OCT-15:00 | 2563.63 | 12-JUN-17:10 |
| Heating:EnergyTransfer:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 55.10 | 15-JAN-11:10 |
| General:Heating:EnergyTransfer:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 55.10 | 15-JAN-11:10 |
| Cooling:EnergyTransfer:Zone:G NW APARTMENT | 39.10 | 0.00 | 01-JAN-07:00 | 2563.63 | 12-JUN-17:10 |
| General:Cooling:EnergyTransfer:Zone:G NW APARTMENT | 39.10 | 0.00 | 01-JAN-07:00 | 2563.63 | 12-JUN-17:10 |
| EnergyTransfer:Zone:OFFICE | 32.88 | 0.26 | 02-DEC-15:20 | 4383.38 | 21-FEB-07:20 |
| Heating:EnergyTransfer:Zone:OFFICE | 5.10 | 0.00 | 01-JAN-13:10 | 592.70 | 09-MAY-17:40 |
| General:Heating:EnergyTransfer:Zone:OFFICE | 5.10 | 0.00 | 01-JAN-13:10 | 592.70 | 09-MAY-17:40 |
| Cooling:EnergyTransfer:Zone:OFFICE | 27.78 | 0.00 | 01-JAN-00:10 | 4383.38 | 21-FEB-07:20 |
| General:Cooling:EnergyTransfer:Zone:OFFICE | 27.78 | 0.00 | 01-JAN-00:10 | 4383.38 | 21-FEB-07:20 |
| EnergyTransfer:Zone:G NE APARTMENT | 39.20 | 0.01 | 30-OCT-15:00 | 2288.17 | 13-JUN-16:10 |
| Heating:EnergyTransfer:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 56.40 | 15-JAN-11:10 |
| General:Heating:EnergyTransfer:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 56.40 | 15-JAN-11:10 |
| Cooling:EnergyTransfer:Zone:G NE APARTMENT | 39.20 | 0.00 | 01-JAN-07:00 | 2288.17 | 13-JUN-16:10 |
| General:Cooling:EnergyTransfer:Zone:G NE APARTMENT | 39.20 | 0.00 | 01-JAN-07:00 | 2288.17 | 13-JUN-16:10 |
| EnergyTransfer:Zone:G N1 APARTMENT | 32.14 | 0.01 | 31-DEC-07:30 | 1864.45 | 21-AUG-12:10 |
| Heating:EnergyTransfer:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 53.54 | 15-JAN-11:10 |
| General:Heating:EnergyTransfer:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 53.54 | 15-JAN-11:10 |
| Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 32.14 | 0.00 | 01-JAN-07:00 | 1854.16 | 21-AUG-12:10 |
| General:Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 32.14 | 0.00 | 01-JAN-07:00 | 1854.16 | 21-AUG-12:10 |
| EnergyTransfer:Zone:G N2 APARTMENT | 32.15 | 0.01 | 01-JAN-08:00 | 1863.46 | 21-AUG-12:10 |
| Heating:EnergyTransfer:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 53.69 | 15-JAN-11:10 |
| General:Heating:EnergyTransfer:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 53.69 | 15-JAN-11:10 |
| Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 32.15 | 0.00 | 01-JAN-07:00 | 1853.16 | 21-AUG-12:10 |
| General:Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 32.15 | 0.00 | 01-JAN-07:00 | 1853.16 | 21-AUG-12:10 |
| EnergyTransfer:Zone:G S1 APARTMENT | 34.13 | 0.04 | 08-DEC-06:50 | 2138.23 | 31-JAN-11:00 |
| Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 33.58 | 14-APR-16:40 |
| General:Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 33.58 | 14-APR-16:40 |
| Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 34.13 | 0.00 | 01-JAN-07:00 | 2122.91 | 31-JAN-11:00 |
| General:Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 34.13 | 0.00 | 01-JAN-07:00 | 2122.91 | 31-JAN-11:00 |
| EnergyTransfer:Zone:G S2 APARTMENT | 37.20 | 0.00 | 18-DEC-06:50 | 2176.18 | 31-JAN-11:00 |
| Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 32.73 | 14-APR-16:40 |
| General:Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 32.73 | 14-APR-16:40 |
| Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 37.20 | 0.00 | 01-JAN-07:00 | 2160.92 | 31-JAN-11:00 |
| General:Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 37.20 | 0.00 | 01-JAN-07:00 | 2160.92 | 31-JAN-11:00 |
| EnergyTransfer:Zone:M SW APARTMENT | 77.79 | 0.04 | 31-OCT-06:00 | 5322.28 | 16-JAN-16:10 |
| Heating:EnergyTransfer:Zone:M SW APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 66.06 | 14-APR-16:40 |
| General:Heating:EnergyTransfer:Zone:M SW APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 66.06 | 14-APR-16:40 |
| Cooling:EnergyTransfer:Zone:M SW APARTMENT | 77.78 | 0.00 | 01-JAN-07:00 | 5322.28 | 16-JAN-16:10 |
| General:Cooling:EnergyTransfer:Zone:M SW APARTMENT | 77.78 | 0.00 | 01-JAN-07:00 | 5322.28 | 16-JAN-16:10 |
| EnergyTransfer:Zone:M NW APARTMENT | 73.74 | 0.06 | 24-DEC-08:40 | 5266.12 | 12-JUN-16:30 |
| Heating:EnergyTransfer:Zone:M NW APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 97.81 | 21-FEB-10:50 |
| General:Heating:EnergyTransfer:Zone:M NW APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 97.81 | 21-FEB-10:50 |
| Cooling:EnergyTransfer:Zone:M NW APARTMENT | 73.73 | 0.00 | 01-JAN-07:00 | 5266.12 | 12-JUN-16:30 |
| General:Cooling:EnergyTransfer:Zone:M NW APARTMENT | 73.73 | 0.00 | 01-JAN-07:00 | 5266.12 | 12-JUN-16:30 |
| EnergyTransfer:Zone:M SE APARTMENT | 78.02 | 0.08 | 26-FEB-06:50 | 5618.74 | 23-FEB-11:00 |
| Heating:EnergyTransfer:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 68.39 | 14-APR-16:40 |
| General:Heating:EnergyTransfer:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 68.39 | 14-APR-16:40 |
| Cooling:EnergyTransfer:Zone:M SE APARTMENT | 78.02 | 0.00 | 01-JAN-07:00 | 5618.74 | 23-FEB-11:00 |
| General:Cooling:EnergyTransfer:Zone:M SE APARTMENT | 78.02 | 0.00 | 01-JAN-07:00 | 5618.74 | 23-FEB-11:00 |
| EnergyTransfer:Zone:M NE APARTMENT | 73.96 | 0.12 | 01-DEC-07:50 | 4665.04 | 23-FEB-11:10 |
| Heating:EnergyTransfer:Zone:M NE APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 106.39 | 15-JAN-11:10 |
| General:Heating:EnergyTransfer:Zone:M NE APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 106.39 | 15-JAN-11:10 |
| Cooling:EnergyTransfer:Zone:M NE APARTMENT | 73.96 | 0.00 | 01-JAN-07:00 | 4665.04 | 23-FEB-11:10 |
| General:Cooling:EnergyTransfer:Zone:M NE APARTMENT | 73.96 | 0.00 | 01-JAN-07:00 | 4665.04 | 23-FEB-11:10 |
| EnergyTransfer:Zone:M N1 APARTMENT | 59.67 | 0.01 | 16-SEP-21:00 | 3904.83 | 03-JUL-14:30 |
| Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 136.66 | 21-FEB-11:00 |
| General:Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 136.66 | 21-FEB-11:00 |
| Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 59.65 | 0.00 | 01-JAN-07:00 | 3892.70 | 03-JUL-14:30 |
| General:Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 59.65 | 0.00 | 01-JAN-07:00 | 3892.70 | 03-JUL-14:30 |
| EnergyTransfer:Zone:M N2 APARTMENT | 59.69 | 0.01 | 16-SEP-21:00 | 3904.14 | 03-JUL-14:30 |
| Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 136.35 | 21-FEB-11:00 |
| General:Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 136.35 | 21-FEB-11:00 |
| Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 59.68 | 0.00 | 01-JAN-07:00 | 3892.00 | 03-JUL-14:30 |
| General:Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 59.68 | 0.00 | 01-JAN-07:00 | 3892.00 | 03-JUL-14:30 |
| EnergyTransfer:Zone:M S1 APARTMENT | 63.76 | 0.01 | 29-JAN-08:00 | 4339.54 | 22-JAN-11:20 |
| Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 94.00 | 14-APR-16:50 |
| General:Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 94.00 | 14-APR-16:50 |
| Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 63.75 | 0.00 | 01-JAN-07:00 | 4315.00 | 22-JAN-11:20 |
| General:Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 63.75 | 0.00 | 01-JAN-07:00 | 4315.00 | 22-JAN-11:20 |
| EnergyTransfer:Zone:M S2 APARTMENT | 63.78 | 0.04 | 15-SEP-18:20 | 4380.55 | 22-JAN-11:20 |
| Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 94.05 | 14-APR-16:50 |
| General:Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 94.05 | 14-APR-16:50 |
| Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 63.77 | 0.00 | 01-JAN-07:00 | 4356.01 | 22-JAN-11:20 |
| General:Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 63.77 | 0.00 | 01-JAN-07:00 | 4356.01 | 22-JAN-11:20 |
| EnergyTransfer:Zone:T SW APARTMENT | 42.20 | 0.02 | 23-OCT-06:40 | 3326.38 | 19-MAR-15:30 |
| Heating:EnergyTransfer:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 23.76 | 14-APR-17:00 |
| General:Heating:EnergyTransfer:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 23.76 | 14-APR-17:00 |
| Cooling:EnergyTransfer:Zone:T SW APARTMENT | 42.19 | 0.00 | 01-JAN-07:00 | 3326.38 | 19-MAR-15:30 |
| General:Cooling:EnergyTransfer:Zone:T SW APARTMENT | 42.19 | 0.00 | 01-JAN-07:00 | 3326.38 | 19-MAR-15:30 |
| EnergyTransfer:Zone:T NW APARTMENT | 40.09 | 0.02 | 27-JAN-07:00 | 3338.86 | 12-JUN-16:30 |
| Heating:EnergyTransfer:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 55.88 | 15-JAN-11:10 |
| General:Heating:EnergyTransfer:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 55.88 | 15-JAN-11:10 |
| Cooling:EnergyTransfer:Zone:T NW APARTMENT | 40.09 | 0.00 | 01-JAN-07:00 | 3338.86 | 12-JUN-16:30 |
| General:Cooling:EnergyTransfer:Zone:T NW APARTMENT | 40.09 | 0.00 | 01-JAN-07:00 | 3338.86 | 12-JUN-16:30 |
| EnergyTransfer:Zone:T SE APARTMENT | 42.32 | 0.01 | 23-OCT-06:40 | 3697.98 | 21-FEB-11:10 |
| Heating:EnergyTransfer:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 25.95 | 30-JUN-13:50 |
| General:Heating:EnergyTransfer:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 25.95 | 30-JUN-13:50 |
| Cooling:EnergyTransfer:Zone:T SE APARTMENT | 42.31 | 0.00 | 01-JAN-07:00 | 3697.98 | 21-FEB-11:10 |
| General:Cooling:EnergyTransfer:Zone:T SE APARTMENT | 42.31 | 0.00 | 01-JAN-07:00 | 3697.98 | 21-FEB-11:10 |
| EnergyTransfer:Zone:T NE APARTMENT | 40.19 | 0.01 | 19-JAN-08:00 | 3124.72 | 23-FEB-11:10 |
| Heating:EnergyTransfer:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 36.78 | 08-JAN-10:40 |
| General:Heating:EnergyTransfer:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 36.78 | 08-JAN-10:40 |
| Cooling:EnergyTransfer:Zone:T NE APARTMENT | 40.19 | 0.00 | 01-JAN-07:00 | 3124.72 | 23-FEB-11:10 |
| General:Cooling:EnergyTransfer:Zone:T NE APARTMENT | 40.19 | 0.00 | 01-JAN-07:00 | 3124.72 | 23-FEB-11:10 |
| EnergyTransfer:Zone:T N1 APARTMENT | 32.95 | 0.01 | 30-OCT-19:30 | 2401.25 | 03-JUL-14:30 |
| Heating:EnergyTransfer:Zone:T N1 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 57.07 | 15-JAN-11:10 |
| General:Heating:EnergyTransfer:Zone:T N1 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 57.07 | 15-JAN-11:10 |
| Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 32.94 | 0.00 | 01-JAN-07:00 | 2401.25 | 03-JUL-14:30 |
| General:Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 32.94 | 0.00 | 01-JAN-07:00 | 2401.25 | 03-JUL-14:30 |
| EnergyTransfer:Zone:T N2 APARTMENT | 32.96 | 0.01 | 30-OCT-19:30 | 2402.73 | 03-JUL-14:30 |
| Heating:EnergyTransfer:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 57.26 | 15-JAN-11:10 |
| General:Heating:EnergyTransfer:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 57.26 | 15-JAN-11:10 |
| Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 32.96 | 0.00 | 01-JAN-07:00 | 2402.73 | 03-JUL-14:30 |
| General:Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 32.96 | 0.00 | 01-JAN-07:00 | 2402.73 | 03-JUL-14:30 |
| EnergyTransfer:Zone:T S1 APARTMENT | 35.08 | 0.01 | 31-DEC-07:30 | 2859.11 | 22-JAN-11:20 |
| Heating:EnergyTransfer:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 32.93 | 14-APR-16:40 |
| General:Heating:EnergyTransfer:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 32.93 | 14-APR-16:40 |
| Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 35.08 | 0.00 | 01-JAN-07:00 | 2859.11 | 22-JAN-11:20 |
| General:Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 35.08 | 0.00 | 01-JAN-07:00 | 2859.11 | 22-JAN-11:20 |
| EnergyTransfer:Zone:T S2 APARTMENT | 35.09 | 0.03 | 20-AUG-06:50 | 2886.32 | 22-JAN-11:20 |
| Heating:EnergyTransfer:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 33.01 | 14-APR-16:40 |
| General:Heating:EnergyTransfer:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 33.01 | 14-APR-16:40 |
| Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 35.09 | 0.00 | 01-JAN-07:00 | 2886.32 | 22-JAN-11:20 |
| General:Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 35.09 | 0.00 | 01-JAN-07:00 | 2886.32 | 22-JAN-11:20 |
| EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| PlantLoopHeatingDemand:Facility | 227.48 | 131.65 | 13-JUL-01:50 | 14351.15 | 13-JAN-08:00 |
| PlantLoopHeatingDemand:Plant | 227.48 | 131.65 | 13-JUL-01:50 | 14351.15 | 13-JAN-08:00 |
| WaterSystems:PlantLoopHeatingDemand | 227.48 | 131.65 | 13-JUL-01:50 | 14351.15 | 13-JAN-08:00 |
| General:WaterSystems:PlantLoopHeatingDemand | 227.48 | 131.65 | 13-JUL-01:50 | 14351.15 | 13-JAN-08:00 |
| EnergyTransfer:HVAC | 2062.05 | 78.09 | 23-JAN-22:40 | 124120.82 | 01-DEC-08:50 |
| HeatRecoveryForHeating:EnergyTransfer | 0.31 | 0.00 | 01-JAN-00:10 | 4143.00 | 24-JAN-10:00 |
| HeatRecoveryForCooling:EnergyTransfer | 295.86 | 0.00 | 08-JAN-09:50 | 19601.47 | 15-JUN-10:00 |
| CoolingCoils:EnergyTransfer | 1765.88 | 0.00 | 01-JAN-07:00 | 119162.03 | 20-AUG-13:20 |
| HeatingCoils:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Plant | 227.47 | 131.65 | 13-JUL-01:50 | 14349.68 | 13-JAN-08:00 |
| WaterSystems:EnergyTransfer | 227.47 | 131.65 | 13-JUL-01:50 | 14349.68 | 13-JAN-08:00 |
| WaterUse:WaterSystems:EnergyTransfer | 227.47 | 131.65 | 13-JUL-01:50 | 14349.68 | 13-JAN-08:00 |
| Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
Annual Building Sensible Heat Gain Components| HVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
| G SW APARTMENT | 2.009 | -0.013 | 0.000 | -42.911 | 0.000 | 0.000 | 3.545 | 0.918 | 12.213 | 9.502 | 0.000 | 0.350 | 14.922 | 0.000 | -0.500 | 0.000 | -0.035 | 0.000 |
| G NW APARTMENT | 2.008 | -0.012 | 0.000 | -41.092 | 0.000 | 0.000 | 3.594 | 0.918 | 12.213 | 8.342 | 0.000 | 0.350 | 14.220 | 0.000 | -0.502 | 0.000 | -0.040 | 0.000 |
| OFFICE | 0.000 | 0.000 | 5.097 | -27.776 | 0.000 | 0.000 | 2.001 | 5.679 | 7.520 | 8.521 | 0.000 | 0.188 | 0.454 | 0.000 | -1.586 | 0.000 | -0.097 | -0.000 |
| G NE APARTMENT | 2.007 | -0.013 | 0.000 | -41.194 | 0.000 | 0.000 | 3.593 | 0.918 | 12.213 | 8.330 | 0.000 | 0.350 | 14.312 | 0.000 | -0.480 | 0.000 | -0.037 | 0.000 |
| G N1 APARTMENT | 2.008 | -0.012 | 0.000 | -34.130 | 0.000 | 0.000 | 3.595 | 0.918 | 12.213 | 4.295 | 0.000 | 0.211 | 11.222 | 0.000 | -0.283 | 0.000 | -0.037 | 0.000 |
| G N2 APARTMENT | 2.008 | -0.012 | 0.000 | -34.139 | 0.000 | 0.000 | 3.595 | 0.918 | 12.213 | 4.295 | 0.000 | 0.211 | 11.231 | 0.000 | -0.283 | 0.000 | -0.037 | 0.000 |
| G S1 APARTMENT | 2.009 | -0.013 | 0.000 | -36.122 | 0.000 | 0.000 | 3.545 | 0.918 | 12.213 | 5.469 | 0.000 | 0.211 | 12.082 | 0.000 | -0.281 | 0.000 | -0.032 | 0.000 |
| G S2 APARTMENT | 2.009 | -0.014 | 0.000 | -39.189 | 0.000 | 0.000 | 3.544 | 0.918 | 12.213 | 5.435 | 0.000 | 0.211 | 15.198 | 0.000 | -0.298 | 0.000 | -0.028 | 0.000 |
| M SW APARTMENT | 4.019 | -0.022 | 0.000 | -81.771 | 0.000 | 0.000 | 7.095 | 1.837 | 24.426 | 19.250 | 0.000 | 1.002 | 25.110 | 0.000 | -0.852 | 0.000 | -0.093 | 0.000 |
| M NW APARTMENT | 4.018 | -0.020 | 0.000 | -77.720 | 0.000 | 0.000 | 7.193 | 1.837 | 24.426 | 16.930 | 0.000 | 1.002 | 23.296 | 0.000 | -0.861 | 0.000 | -0.100 | 0.000 |
| M SE APARTMENT | 4.019 | -0.024 | 0.000 | -82.007 | 0.000 | 0.000 | 7.093 | 1.837 | 24.426 | 19.254 | 0.000 | 1.002 | 25.320 | 0.000 | -0.833 | 0.000 | -0.086 | 0.000 |
| M NE APARTMENT | 4.016 | -0.022 | 0.000 | -77.943 | 0.000 | 0.000 | 7.191 | 1.837 | 24.426 | 16.911 | 0.000 | 1.002 | 23.499 | 0.000 | -0.821 | 0.000 | -0.097 | 0.000 |
| M N1 APARTMENT | 4.018 | -0.020 | 0.000 | -63.641 | 0.000 | 0.000 | 7.194 | 1.837 | 24.426 | 8.725 | 0.000 | 0.604 | 17.446 | 0.000 | -0.495 | 0.000 | -0.094 | 0.000 |
| M N2 APARTMENT | 4.018 | -0.020 | 0.000 | -63.663 | 0.000 | 0.000 | 7.194 | 1.837 | 24.426 | 8.724 | 0.000 | 0.604 | 17.468 | 0.000 | -0.495 | 0.000 | -0.094 | 0.000 |
| M S1 APARTMENT | 4.019 | -0.022 | 0.000 | -67.738 | 0.000 | 0.000 | 7.095 | 1.837 | 24.426 | 11.076 | 0.000 | 0.605 | 19.272 | 0.000 | -0.485 | 0.000 | -0.085 | 0.000 |
| M S2 APARTMENT | 4.019 | -0.022 | 0.000 | -67.758 | 0.000 | 0.000 | 7.095 | 1.837 | 24.426 | 11.076 | 0.000 | 0.605 | 19.292 | 0.000 | -0.485 | 0.000 | -0.085 | 0.000 |
| T SW APARTMENT | 2.010 | -0.011 | 0.000 | -44.189 | 0.000 | 0.000 | 3.548 | 0.918 | 12.213 | 9.398 | 0.000 | 0.658 | 15.924 | 0.000 | -0.417 | 0.000 | -0.052 | 0.000 |
| T NW APARTMENT | 2.009 | -0.010 | 0.000 | -42.080 | 0.000 | 0.000 | 3.597 | 0.918 | 12.213 | 8.249 | 0.000 | 0.657 | 14.924 | 0.000 | -0.423 | 0.000 | -0.055 | 0.000 |
| T SE APARTMENT | 2.010 | -0.012 | 0.000 | -44.309 | 0.000 | 0.000 | 3.547 | 0.918 | 12.213 | 9.396 | 0.000 | 0.657 | 16.035 | 0.000 | -0.405 | 0.000 | -0.049 | 0.000 |
| T NE APARTMENT | 2.008 | -0.011 | 0.000 | -42.182 | 0.000 | 0.000 | 3.596 | 0.918 | 12.213 | 8.237 | 0.000 | 0.657 | 15.020 | 0.000 | -0.402 | 0.000 | -0.054 | 0.000 |
| T N1 APARTMENT | 2.009 | -0.010 | 0.000 | -34.934 | 0.000 | 0.000 | 3.597 | 0.918 | 12.213 | 4.252 | 0.000 | 0.396 | 11.859 | 0.000 | -0.249 | 0.000 | -0.050 | 0.000 |
| T N2 APARTMENT | 2.009 | -0.010 | 0.000 | -34.949 | 0.000 | 0.000 | 3.597 | 0.918 | 12.213 | 4.251 | 0.000 | 0.396 | 11.873 | 0.000 | -0.249 | 0.000 | -0.050 | 0.000 |
| T S1 APARTMENT | 2.010 | -0.011 | 0.000 | -37.073 | 0.000 | 0.000 | 3.548 | 0.918 | 12.213 | 5.420 | 0.000 | 0.397 | 12.868 | 0.000 | -0.243 | 0.000 | -0.046 | 0.000 |
| T S2 APARTMENT | 2.010 | -0.011 | 0.000 | -37.087 | 0.000 | 0.000 | 3.548 | 0.918 | 12.213 | 5.419 | 0.000 | 0.397 | 12.881 | 0.000 | -0.242 | 0.000 | -0.046 | 0.000 |
| T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.133 | 9.711 | 0.000 | 0.905 | 0.000 | 0.058 | 0.000 | 0.000 | -0.078 | 0.000 | -0.009 | -15.719 |
| G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.443 | 9.711 | 3.395 | 2.563 | 0.000 | 3.198 | 0.000 | 0.000 | -0.357 | 0.000 | -2.204 | -20.748 |
| M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 10.399 | 19.423 | 0.000 | 1.850 | 0.000 | 0.101 | 0.000 | 0.000 | -0.152 | 0.000 | -0.014 | -31.606 |
| Total Facility | 62.274 | -0.345 | 5.097 | -1195.594 | 0.000 | 0.000 | 132.714 | 72.996 | 389.511 | 226.074 | 0.000 | 16.082 | 375.727 | 0.000 | -12.757 | 0.000 | -3.705 | -68.074 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| G SW APARTMENT | 20-DEC-21:32 | 0.00 | 7.90 | 0.00 | -4790.82 | 0.00 | 0.00 | 146.44 | 60.30 | 500.33 | 0.00 | 0.00 | 0.00 | 4233.87 | 0.00 | -148.86 | 0.00 | -9.17 | 0.00 |
| G NW APARTMENT | 20-DEC-22:02 | 0.00 | 1.65 | 0.00 | -4695.37 | 0.00 | 0.00 | 145.07 | 32.89 | 417.92 | 0.00 | 0.00 | 0.00 | 4266.51 | 0.00 | -158.09 | 0.00 | -10.60 | 0.00 |
| OFFICE | 23-JAN-07:01 | 0.00 | 0.00 | 0.00 | -5814.12 | 0.00 | 0.00 | 0.00 | 89.52 | 194.98 | 330.11 | 0.00 | 0.00 | 5214.81 | 0.00 | -0.00 | 0.00 | -15.30 | 0.00 |
| G NE APARTMENT | 20-DEC-22:02 | 0.00 | 0.52 | 0.00 | -4471.42 | 0.00 | 0.00 | 145.07 | 32.89 | 417.92 | 0.00 | 0.00 | 0.00 | 4043.44 | 0.00 | -157.73 | 0.00 | -10.71 | 0.00 |
| G N1 APARTMENT | 20-DEC-22:02 | 0.00 | -1.69 | 0.00 | -4019.49 | 0.00 | 0.00 | 145.07 | 32.89 | 417.92 | 0.00 | 0.00 | 0.00 | 3525.54 | 0.00 | -93.66 | 0.00 | -6.59 | 0.00 |
| G N2 APARTMENT | 20-DEC-22:02 | 0.00 | -1.71 | 0.00 | -4014.78 | 0.00 | 0.00 | 145.07 | 32.89 | 417.92 | 0.00 | 0.00 | 0.00 | 3520.86 | 0.00 | -93.66 | 0.00 | -6.59 | 0.00 |
| G S1 APARTMENT | 20-DEC-21:32 | 0.00 | 4.27 | 0.00 | -4133.98 | 0.00 | 0.00 | 145.80 | 60.30 | 500.33 | 0.00 | 0.00 | 0.00 | 3517.49 | 0.00 | -88.38 | 0.00 | -5.82 | 0.00 |
| G S2 APARTMENT | 20-DEC-21:32 | 0.00 | 4.57 | 0.00 | -4177.29 | 0.00 | 0.00 | 146.16 | 60.30 | 500.33 | 0.00 | 0.00 | 0.00 | 3561.05 | 0.00 | -89.36 | 0.00 | -5.76 | 0.00 |
| M SW APARTMENT | 20-DEC-21:32 | 0.00 | 18.45 | 0.00 | -10324.67 | 0.00 | 0.00 | 290.44 | 120.61 | 1000.66 | 0.00 | 0.00 | 0.00 | 9216.13 | 0.00 | -294.83 | 0.00 | -26.80 | 0.00 |
| M NW APARTMENT | 23-JAN-22:52 | 0.00 | 29.71 | 0.00 | -9976.99 | 0.00 | 0.00 | 299.22 | 65.79 | 835.84 | 0.00 | 0.00 | 0.00 | 8988.28 | 0.00 | -225.50 | 0.00 | -16.34 | 0.00 |
| M SE APARTMENT | 21-FEB-10:42 | 0.00 | 126.65 | 0.00 | -10126.47 | 0.00 | 0.00 | 0.00 | 21.93 | 812.30 | 2093.91 | 0.00 | 12.53 | 7059.16 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 23-JAN-22:52 | 0.00 | 26.82 | 0.00 | -9503.49 | 0.00 | 0.00 | 298.68 | 65.79 | 835.84 | 0.00 | 0.00 | 0.00 | 8520.15 | 0.00 | -227.02 | 0.00 | -16.76 | 0.00 |
| M N1 APARTMENT | 23-JAN-22:52 | 0.00 | 23.75 | 0.00 | -8533.97 | 0.00 | 0.00 | 300.84 | 65.79 | 835.84 | 0.00 | 0.00 | 0.00 | 7450.70 | 0.00 | -132.90 | 0.00 | -10.05 | 0.00 |
| M N2 APARTMENT | 23-JAN-22:52 | 0.00 | 23.66 | 0.00 | -8525.89 | 0.00 | 0.00 | 300.79 | 65.79 | 835.84 | 0.00 | 0.00 | 0.00 | 7442.85 | 0.00 | -132.98 | 0.00 | -10.06 | 0.00 |
| M S1 APARTMENT | 20-DEC-21:32 | 0.00 | 10.76 | 0.00 | -8881.98 | 0.00 | 0.00 | 290.14 | 120.61 | 1000.66 | 0.00 | 0.00 | 0.00 | 7651.84 | 0.00 | -175.13 | 0.00 | -16.89 | 0.00 |
| M S2 APARTMENT | 20-DEC-21:32 | 0.00 | 10.70 | 0.00 | -8871.07 | 0.00 | 0.00 | 290.14 | 120.61 | 1000.66 | 0.00 | 0.00 | 0.00 | 7640.97 | 0.00 | -175.12 | 0.00 | -16.89 | 0.00 |
| T SW APARTMENT | 21-FEB-10:42 | 0.00 | 62.79 | 0.00 | -5590.80 | 0.00 | 0.00 | 0.00 | 10.96 | 406.15 | 798.96 | 0.00 | 7.30 | 4304.64 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 20-DEC-22:02 | 0.00 | 5.35 | 0.00 | -5366.72 | 0.00 | 0.00 | 145.07 | 32.89 | 417.92 | 0.00 | 0.00 | 0.00 | 4946.45 | 0.00 | -161.15 | 0.00 | -19.82 | 0.00 |
| T SE APARTMENT | 21-FEB-10:42 | 0.00 | 52.92 | 0.00 | -5577.03 | 0.00 | 0.00 | 0.00 | 10.96 | 406.15 | 1003.34 | 0.00 | 4.24 | 4099.41 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 21-FEB-10:52 | 0.00 | 79.77 | 0.00 | -5291.54 | 0.00 | 0.00 | 30.47 | 10.96 | 406.15 | 602.89 | 0.00 | 12.20 | 4149.10 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 23-JAN-22:52 | 0.00 | 12.28 | 0.00 | -4626.59 | 0.00 | 0.00 | 148.56 | 32.89 | 417.92 | 0.00 | 0.00 | 0.00 | 4091.50 | 0.00 | -69.54 | 0.00 | -7.02 | 0.00 |
| T N2 APARTMENT | 23-JAN-22:52 | 0.00 | 12.20 | 0.00 | -4613.05 | 0.00 | 0.00 | 148.55 | 32.89 | 417.92 | 0.00 | 0.00 | 0.00 | 4078.09 | 0.00 | -69.57 | 0.00 | -7.03 | 0.00 |
| T S1 APARTMENT | 20-DEC-21:32 | 0.00 | 7.28 | 0.00 | -4753.05 | 0.00 | 0.00 | 145.81 | 60.30 | 500.33 | 0.00 | 0.00 | 0.00 | 4141.35 | 0.00 | -91.08 | 0.00 | -10.94 | 0.00 |
| T S2 APARTMENT | 21-FEB-10:42 | 0.00 | 60.89 | 0.00 | -4799.15 | 0.00 | 0.00 | 0.00 | 10.96 | 406.15 | 653.02 | 0.00 | 4.55 | 3663.58 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 23-JAN-22:52 | -145.86 | 513.43 | 145.86 | -142650.44 | 0.00 | 0.00 | 5529.67 | 2341.03 | 13164.90 | 0.00 | 0.00 | 0.00 | 124468.57 | 0.00 | -3125.16 | 0.00 | -242.01 | 0.00 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| G SW APARTMENT | 21-FEB-10:43 | 58.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.96 | 406.15 | 826.26 | 0.00 | 5.27 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1307.42 |
| G NW APARTMENT | 15-JAN-11:17 | 78.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.45 | 10.96 | 412.04 | 495.03 | 0.00 | 16.61 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1049.68 |
| OFFICE | 05-MAY-16:13 | 0.00 | 0.00 | 736.84 | 0.00 | 0.00 | 0.00 | 0.00 | 89.52 | 194.98 | 403.52 | 0.00 | 50.40 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1475.27 |
| G NE APARTMENT | 14-APR-16:57 | 80.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 75.44 | 54.82 | 588.62 | 163.54 | 0.00 | 7.14 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -970.16 |
| G N1 APARTMENT | 21-FEB-11:17 | 98.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.27 | 10.96 | 412.04 | 290.44 | 0.00 | 8.04 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -856.21 |
| G N2 APARTMENT | 21-FEB-11:17 | 98.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.27 | 10.96 | 412.04 | 290.29 | 0.00 | 8.05 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -856.13 |
| G S1 APARTMENT | 21-FEB-11:07 | 94.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.96 | 412.04 | 722.86 | 0.00 | 7.63 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1247.73 |
| G S2 APARTMENT | 31-JAN-10:57 | 91.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.96 | 406.15 | 811.93 | 0.00 | 10.32 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1330.90 |
| M SW APARTMENT | 21-FEB-11:05 | 199.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.93 | 824.07 | 1804.37 | 0.00 | 36.21 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -2885.67 |
| M NW APARTMENT | 21-FEB-11:15 | 209.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.54 | 21.93 | 824.07 | 956.79 | 0.00 | 38.41 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -2123.24 |
| M SE APARTMENT | 30-JUN-13:55 | 131.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.93 | 765.21 | 670.21 | 0.00 | 8.69 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1597.47 |
| M NE APARTMENT | 15-JAN-11:17 | 157.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.56 | 21.93 | 824.07 | 1100.16 | 0.00 | 47.64 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -2224.26 |
| M N1 APARTMENT | 23-FEB-11:07 | 185.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.54 | 21.93 | 824.07 | 570.60 | 0.00 | 21.38 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1695.72 |
| M N2 APARTMENT | 23-FEB-11:07 | 185.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.54 | 21.93 | 824.07 | 570.24 | 0.00 | 21.39 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1695.51 |
| M S1 APARTMENT | 22-JAN-11:17 | 147.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 145.07 | 21.93 | 824.07 | 1415.14 | 0.00 | 11.30 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -2564.73 |
| M S2 APARTMENT | 22-JAN-11:17 | 147.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 145.07 | 21.93 | 824.07 | 1414.86 | 0.00 | 11.29 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -2564.41 |
| T SW APARTMENT | 14-APR-16:55 | 89.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 54.82 | 588.62 | 312.76 | 0.00 | 13.69 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1059.00 |
| T NW APARTMENT | 31-JAN-10:55 | 96.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.27 | 10.96 | 406.15 | 466.84 | 0.00 | 32.13 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1049.03 |
| T SE APARTMENT | 30-JUN-13:55 | 67.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.96 | 382.60 | 321.96 | 0.00 | 5.67 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -788.27 |
| T NE APARTMENT | 21-FEB-10:56 | 69.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.47 | 10.96 | 406.15 | 602.89 | 0.00 | 15.17 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1135.52 |
| T N1 APARTMENT | 08-JAN-10:47 | 79.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.27 | 10.96 | 406.15 | 280.61 | 0.00 | 8.52 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -821.74 |
| T N2 APARTMENT | 08-JAN-10:47 | 79.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.27 | 10.96 | 406.15 | 280.30 | 0.00 | 8.51 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -821.41 |
| T S1 APARTMENT | 30-JUN-13:55 | 65.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.96 | 382.60 | 199.88 | 0.00 | 3.38 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -662.45 |
| T S2 APARTMENT | 30-JUN-13:55 | 65.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.96 | 382.60 | 199.81 | 0.00 | 3.37 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -662.31 |
| T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 01-DEC-08:47 | -1523.29 | 3196.38 | 0.00 | -3196.38 | 0.00 | 0.00 | 1597.02 | 2189.27 | 12778.33 | 16028.91 | 0.00 | 165.28 | 0.00 | 0.00 | 0.00 | 0.00 | -90.31 | -31145.21 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
System Ventilation Requirements for Cooling| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| SPLIT GSW | 0.3128 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3128 | 0.0830 | 1.0000 | Not calculated | 0.0260 | 0.0830 | ||
| SPLIT GNW | 0.3161 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3161 | 0.0821 | 1.0000 | Not calculated | 0.0260 | 0.0821 | ||
| SPLIT OFFICE | 0.3723 | 0.0000 | 4.7495 | 1.0000 | Calculated from schedules | 0.0381 | 0.3723 | 0.1024 | 1.0000 | Not calculated | 0.0381 | 0.1024 | ||
| SPLIT GNE | 0.2968 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2968 | 0.0874 | 1.0000 | Not calculated | 0.0260 | 0.0874 | ||
| SPLIT GN1 | 0.2638 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2638 | 0.0984 | 1.0000 | Not calculated | 0.0260 | 0.0984 | ||
| SPLIT GN2 | 0.2634 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2634 | 0.0985 | 1.0000 | Not calculated | 0.0260 | 0.0985 | ||
| SPLIT GS1 | 0.2606 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2606 | 0.0996 | 1.0000 | Not calculated | 0.0260 | 0.0996 | ||
| SPLIT GS2 | 0.2634 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2634 | 0.0986 | 1.0000 | Not calculated | 0.0260 | 0.0986 | ||
| SPLIT MSW | 0.6905 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6905 | 0.0752 | 1.0000 | Not calculated | 0.0519 | 0.0752 | ||
| SPLIT MNW | 0.6977 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6977 | 0.0744 | 1.0000 | Not calculated | 0.0519 | 0.0744 | ||
| SPLIT MSE | 0.6427 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6427 | 0.0808 | 1.0000 | Not calculated | 0.0519 | 0.0808 | ||
| SPLIT MNE | 0.6498 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6498 | 0.0799 | 1.0000 | Not calculated | 0.0519 | 0.0799 | ||
| SPLIT MN1 | 0.5782 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.5782 | 0.0898 | 1.0000 | Not calculated | 0.0519 | 0.0898 | ||
| SPLIT MN2 | 0.5773 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.5773 | 0.0899 | 1.0000 | Not calculated | 0.0519 | 0.0899 | ||
| SPLIT MS1 | 0.5711 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.5711 | 0.0909 | 1.0000 | Not calculated | 0.0519 | 0.0909 | ||
| SPLIT MS2 | 0.5702 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.5702 | 0.0910 | 1.0000 | Not calculated | 0.0519 | 0.0910 | ||
| SPLIT TSW | 0.3716 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3716 | 0.0698 | 1.0000 | Not calculated | 0.0260 | 0.0698 | ||
| SPLIT TNW | 0.3773 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3773 | 0.0688 | 1.0000 | Not calculated | 0.0260 | 0.0688 | ||
| SPLIT TSE | 0.3379 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3379 | 0.0768 | 1.0000 | Not calculated | 0.0260 | 0.0768 | ||
| SPLIT TNE | 0.3436 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3436 | 0.0755 | 1.0000 | Not calculated | 0.0260 | 0.0755 | ||
| SPLIT TN1 | 0.3186 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3186 | 0.0815 | 1.0000 | Not calculated | 0.0260 | 0.0815 | ||
| SPLIT TN2 | 0.3174 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3174 | 0.0818 | 1.0000 | Not calculated | 0.0260 | 0.0818 | ||
| SPLIT TS1 | 0.3129 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3129 | 0.0829 | 1.0000 | Not calculated | 0.0260 | 0.0829 | ||
| SPLIT TS2 | 0.3117 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3117 | 0.0833 | 1.0000 | Not calculated | 0.0260 | 0.0833 |
| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| SPLIT GSW | 0.3128 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3128 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0830 | ||
| SPLIT GNW | 0.3161 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3161 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0821 | ||
| SPLIT OFFICE | 0.3723 | 0.0000 | 4.7495 | 1.0000 | Calculated from schedules | 0.0381 | 0.3723 | 1.0000 | 1.0000 | Not calculated | 0.0381 | 0.1024 | ||
| SPLIT GNE | 0.2968 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2968 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0874 | ||
| SPLIT GN1 | 0.2638 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2638 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0984 | ||
| SPLIT GN2 | 0.2634 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2634 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0985 | ||
| SPLIT GS1 | 0.2606 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2606 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0996 | ||
| SPLIT GS2 | 0.2634 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2634 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0986 | ||
| SPLIT MSW | 0.6905 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6905 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0752 | ||
| SPLIT MNW | 0.6977 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6977 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0744 | ||
| SPLIT MSE | 0.6427 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6427 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0808 | ||
| SPLIT MNE | 0.6498 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6498 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0799 | ||
| SPLIT MN1 | 0.5782 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.5782 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0898 | ||
| SPLIT MN2 | 0.5773 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.5773 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0899 | ||
| SPLIT MS1 | 0.5711 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.5711 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0909 | ||
| SPLIT MS2 | 0.5702 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.5702 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0910 | ||
| SPLIT TSW | 0.3716 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3716 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0698 | ||
| SPLIT TNW | 0.3773 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3773 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0688 | ||
| SPLIT TSE | 0.3379 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3379 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0768 | ||
| SPLIT TNE | 0.3436 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3436 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0755 | ||
| SPLIT TN1 | 0.3186 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3186 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0815 | ||
| SPLIT TN2 | 0.3174 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3174 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0818 | ||
| SPLIT TS1 | 0.3129 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3129 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0829 | ||
| SPLIT TS2 | 0.3117 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3117 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0833 |
| AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| G SW APARTMENT | SPLIT GSW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G NW APARTMENT | SPLIT GNW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| OFFICE | SPLIT OFFICE | 0.000000 | 4.7495 | 0.000432 | 88.25 | 0.0381 | 1.0000 | 0.0381 | 1.000 | 0.0381 |
| G NE APARTMENT | SPLIT GNE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G N1 APARTMENT | SPLIT GN1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G N2 APARTMENT | SPLIT GN2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G S1 APARTMENT | SPLIT GS1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G S2 APARTMENT | SPLIT GS2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| M SW APARTMENT | SPLIT MSW | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M NW APARTMENT | SPLIT MNW | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M SE APARTMENT | SPLIT MSE | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M NE APARTMENT | SPLIT MNE | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M N1 APARTMENT | SPLIT MN1 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M N2 APARTMENT | SPLIT MN2 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M S1 APARTMENT | SPLIT MS1 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M S2 APARTMENT | SPLIT MS2 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| T SW APARTMENT | SPLIT TSW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T NW APARTMENT | SPLIT TNW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T SE APARTMENT | SPLIT TSE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T NE APARTMENT | SPLIT TNE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T N1 APARTMENT | SPLIT TN1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T N2 APARTMENT | SPLIT TN2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T S1 APARTMENT | SPLIT TS1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T S2 APARTMENT | SPLIT TS2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| SPLIT GSW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GNW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT OFFICE | 0.000000 | 4.75 | 0.000432 | 88.2493 | 0.0381 | 0.0381 | 0.0381 |
| SPLIT GNE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GN1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GN2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GS1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GS2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT MSW | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MNW | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MSE | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MNE | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MN1 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MN2 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MS1 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MS2 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT TSW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TNW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TSE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TNE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TN1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TN2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TS1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TS2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| G SW APARTMENT | SPLIT GSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3128 | 0.3128 | 0.3128 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NW APARTMENT | SPLIT GNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3161 | 0.3161 | 0.3161 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| OFFICE | SPLIT OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3723 | 0.3723 | 0.3723 | No | 0.0381 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NE APARTMENT | SPLIT GNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2968 | 0.2968 | 0.2968 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N1 APARTMENT | SPLIT GN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2638 | 0.2638 | 0.2638 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N2 APARTMENT | SPLIT GN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2634 | 0.2634 | 0.2634 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S1 APARTMENT | SPLIT GS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2606 | 0.2606 | 0.2606 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S2 APARTMENT | SPLIT GS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2634 | 0.2634 | 0.2634 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SW APARTMENT | SPLIT MSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6905 | 0.6905 | 0.6905 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NW APARTMENT | SPLIT MNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6977 | 0.6977 | 0.6977 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SE APARTMENT | SPLIT MSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6427 | 0.6427 | 0.6427 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NE APARTMENT | SPLIT MNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6498 | 0.6498 | 0.6498 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N1 APARTMENT | SPLIT MN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5782 | 0.5782 | 0.5782 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N2 APARTMENT | SPLIT MN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5773 | 0.5773 | 0.5773 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S1 APARTMENT | SPLIT MS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5711 | 0.5711 | 0.5711 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S2 APARTMENT | SPLIT MS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5702 | 0.5702 | 0.5702 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SW APARTMENT | SPLIT TSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3716 | 0.3716 | 0.3716 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NW APARTMENT | SPLIT TNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3773 | 0.3773 | 0.3773 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SE APARTMENT | SPLIT TSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3379 | 0.3379 | 0.3379 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NE APARTMENT | SPLIT TNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3436 | 0.3436 | 0.3436 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N1 APARTMENT | SPLIT TN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3186 | 0.3186 | 0.3186 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N2 APARTMENT | SPLIT TN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3174 | 0.3174 | 0.3174 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S1 APARTMENT | SPLIT TS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3129 | 0.3129 | 0.3129 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S2 APARTMENT | SPLIT TS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3117 | 0.3117 | 0.3117 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| SPLIT GSW | 0.3128 | 0.3128 | 0.3128 | 0.3128 | 0.0260 | 1.0000 |
| SPLIT GNW | 0.3161 | 0.3161 | 0.3161 | 0.3161 | 0.0260 | 1.0000 |
| SPLIT OFFICE | 0.3723 | 0.3723 | 0.3723 | 0.3723 | 0.0381 | 1.0000 |
| SPLIT GNE | 0.2968 | 0.2968 | 0.2968 | 0.2968 | 0.0260 | 1.0000 |
| SPLIT GN1 | 0.2638 | 0.2638 | 0.2638 | 0.2638 | 0.0260 | 1.0000 |
| SPLIT GN2 | 0.2634 | 0.2634 | 0.2634 | 0.2634 | 0.0260 | 1.0000 |
| SPLIT GS1 | 0.2606 | 0.2606 | 0.2606 | 0.2606 | 0.0260 | 1.0000 |
| SPLIT GS2 | 0.2634 | 0.2634 | 0.2634 | 0.2634 | 0.0260 | 1.0000 |
| SPLIT MSW | 0.6905 | 0.6905 | 0.6905 | 0.6905 | 0.0519 | 1.0000 |
| SPLIT MNW | 0.6977 | 0.6977 | 0.6977 | 0.6977 | 0.0519 | 1.0000 |
| SPLIT MSE | 0.6427 | 0.6427 | 0.6427 | 0.6427 | 0.0519 | 1.0000 |
| SPLIT MNE | 0.6498 | 0.6498 | 0.6498 | 0.6498 | 0.0519 | 1.0000 |
| SPLIT MN1 | 0.5782 | 0.5782 | 0.5782 | 0.5782 | 0.0519 | 1.0000 |
| SPLIT MN2 | 0.5773 | 0.5773 | 0.5773 | 0.5773 | 0.0519 | 1.0000 |
| SPLIT MS1 | 0.5711 | 0.5711 | 0.5711 | 0.5711 | 0.0519 | 1.0000 |
| SPLIT MS2 | 0.5702 | 0.5702 | 0.5702 | 0.5702 | 0.0519 | 1.0000 |
| SPLIT TSW | 0.3716 | 0.3716 | 0.3716 | 0.3716 | 0.0260 | 1.0000 |
| SPLIT TNW | 0.3773 | 0.3773 | 0.3773 | 0.3773 | 0.0260 | 1.0000 |
| SPLIT TSE | 0.3379 | 0.3379 | 0.3379 | 0.3379 | 0.0260 | 1.0000 |
| SPLIT TNE | 0.3436 | 0.3436 | 0.3436 | 0.3436 | 0.0260 | 1.0000 |
| SPLIT TN1 | 0.3186 | 0.3186 | 0.3186 | 0.3186 | 0.0260 | 1.0000 |
| SPLIT TN2 | 0.3174 | 0.3174 | 0.3174 | 0.3174 | 0.0260 | 1.0000 |
| SPLIT TS1 | 0.3129 | 0.3129 | 0.3129 | 0.3129 | 0.0260 | 1.0000 |
| SPLIT TS2 | 0.3117 | 0.3117 | 0.3117 | 0.3117 | 0.0260 | 1.0000 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| G SW APARTMENT | SPLIT GSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3128 | 0.3128 | 0.3128 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NW APARTMENT | SPLIT GNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3161 | 0.3161 | 0.3161 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| OFFICE | SPLIT OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3723 | 0.3723 | 0.3723 | No | 0.0381 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NE APARTMENT | SPLIT GNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2968 | 0.2968 | 0.2968 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N1 APARTMENT | SPLIT GN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2638 | 0.2638 | 0.2638 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N2 APARTMENT | SPLIT GN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2634 | 0.2634 | 0.2634 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S1 APARTMENT | SPLIT GS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2606 | 0.2606 | 0.2606 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S2 APARTMENT | SPLIT GS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2634 | 0.2634 | 0.2634 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SW APARTMENT | SPLIT MSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6905 | 0.6905 | 0.6905 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NW APARTMENT | SPLIT MNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6977 | 0.6977 | 0.6977 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SE APARTMENT | SPLIT MSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6427 | 0.6427 | 0.6427 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NE APARTMENT | SPLIT MNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6498 | 0.6498 | 0.6498 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N1 APARTMENT | SPLIT MN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5782 | 0.5782 | 0.5782 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N2 APARTMENT | SPLIT MN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5773 | 0.5773 | 0.5773 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S1 APARTMENT | SPLIT MS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5711 | 0.5711 | 0.5711 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S2 APARTMENT | SPLIT MS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5702 | 0.5702 | 0.5702 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SW APARTMENT | SPLIT TSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3716 | 0.3716 | 0.3716 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NW APARTMENT | SPLIT TNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3773 | 0.3773 | 0.3773 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SE APARTMENT | SPLIT TSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3379 | 0.3379 | 0.3379 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NE APARTMENT | SPLIT TNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3436 | 0.3436 | 0.3436 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N1 APARTMENT | SPLIT TN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3186 | 0.3186 | 0.3186 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N2 APARTMENT | SPLIT TN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3174 | 0.3174 | 0.3174 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S1 APARTMENT | SPLIT TS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3129 | 0.3129 | 0.3129 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S2 APARTMENT | SPLIT TS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3117 | 0.3117 | 0.3117 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| SPLIT GSW | 0.3128 | 0.3128 | 0.3128 | 0.3128 | 0.0260 | 1.0000 |
| SPLIT GNW | 0.3161 | 0.3161 | 0.3161 | 0.3161 | 0.0260 | 1.0000 |
| SPLIT OFFICE | 0.3723 | 0.3723 | 0.3723 | 0.3723 | 0.0381 | 1.0000 |
| SPLIT GNE | 0.2968 | 0.2968 | 0.2968 | 0.2968 | 0.0260 | 1.0000 |
| SPLIT GN1 | 0.2638 | 0.2638 | 0.2638 | 0.2638 | 0.0260 | 1.0000 |
| SPLIT GN2 | 0.2634 | 0.2634 | 0.2634 | 0.2634 | 0.0260 | 1.0000 |
| SPLIT GS1 | 0.2606 | 0.2606 | 0.2606 | 0.2606 | 0.0260 | 1.0000 |
| SPLIT GS2 | 0.2634 | 0.2634 | 0.2634 | 0.2634 | 0.0260 | 1.0000 |
| SPLIT MSW | 0.6905 | 0.6905 | 0.6905 | 0.6905 | 0.0519 | 1.0000 |
| SPLIT MNW | 0.6977 | 0.6977 | 0.6977 | 0.6977 | 0.0519 | 1.0000 |
| SPLIT MSE | 0.6427 | 0.6427 | 0.6427 | 0.6427 | 0.0519 | 1.0000 |
| SPLIT MNE | 0.6498 | 0.6498 | 0.6498 | 0.6498 | 0.0519 | 1.0000 |
| SPLIT MN1 | 0.5782 | 0.5782 | 0.5782 | 0.5782 | 0.0519 | 1.0000 |
| SPLIT MN2 | 0.5773 | 0.5773 | 0.5773 | 0.5773 | 0.0519 | 1.0000 |
| SPLIT MS1 | 0.5711 | 0.5711 | 0.5711 | 0.5711 | 0.0519 | 1.0000 |
| SPLIT MS2 | 0.5702 | 0.5702 | 0.5702 | 0.5702 | 0.0519 | 1.0000 |
| SPLIT TSW | 0.3716 | 0.3716 | 0.3716 | 0.3716 | 0.0260 | 1.0000 |
| SPLIT TNW | 0.3773 | 0.3773 | 0.3773 | 0.3773 | 0.0260 | 1.0000 |
| SPLIT TSE | 0.3379 | 0.3379 | 0.3379 | 0.3379 | 0.0260 | 1.0000 |
| SPLIT TNE | 0.3436 | 0.3436 | 0.3436 | 0.3436 | 0.0260 | 1.0000 |
| SPLIT TN1 | 0.3186 | 0.3186 | 0.3186 | 0.3186 | 0.0260 | 1.0000 |
| SPLIT TN2 | 0.3174 | 0.3174 | 0.3174 | 0.3174 | 0.0260 | 1.0000 |
| SPLIT TS1 | 0.3129 | 0.3129 | 0.3129 | 0.3129 | 0.0260 | 1.0000 |
| SPLIT TS2 | 0.3117 | 0.3117 | 0.3117 | 0.3117 | 0.0260 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
Sec1.1A-General Information| Data | |
| Weather File | RUNPERIOD 1 ** Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000 |
| Total gross floor area [m2] | 3134.61 |
| Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
| G SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| OFFICE | 88.25 | 88.25 | 0.00 | 33.56 |
| G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M SE APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T SE APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| G CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| M CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| Totals | 3134.61 | 2823.98 | 310.64 |
| Data | |
| Number of hours heating loads not met | 0.00 |
| Number of hours cooling loads not met | 0.00 |
| Number of hours not met | 0.00 |
| Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
| None |
| Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
| Heating -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling -- General | 463.11 | 29029.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- LightsWired | 67.97 | 3560.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- LightsPlugIn | 5.02 | 479.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting -- General | 33.06 | 2101.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- ElevatorLift | 67.41 | 3772.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- ElevatorLightsFan | 0.49 | 31.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- MiscPlug | 386.12 | 18442.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- General | 168.01 | 8579.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps -- General | 0.46 | 14.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems -- WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems -- Water Heater | 0.00 | 0.00 | 297.14 | 18960.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Process Subtotal [GJ] | Total Energy Use [GJ] | |
| Electricity | 454.01 | 1191.65 |
| Natural Gas | 0.00 | 297.14 |
| Additional | 0.00 | 0.00 |
| Total | 454.01 | 1488.79 |
| Process Subtotal [$] | Total Energy Cost [$] | |
| Electricity | 0.00 | |
| Natural Gas | 0.00 | |
| Additional | 0.00 | |
| Total | 0.00 |
| Rated Capacity [kW] | Annual Energy Generated [GJ] | |
| Photovoltaic | 0.00 | 0.00 |
| Wind | 0.00 | 0.00 |
| Electricty [MJ/m2] | |
| Interior Lighting (All) | 23.29 |
| Space Heating | 0.00 |
| Space Cooling | 147.74 |
| Fans (All) | 53.60 |
| Service Water Heating | 0.00 |
| Receptacle Equipment | 144.84 |
| Miscellaneous (All) | 380.16 |
| Subtotal | 380.16 |
| Natural Gas [MJ/m2] | |
| Space Heating | 0.00 |
| Service Water Heating | 94.79 |
| Miscellaneous (All) | 94.79 |
| Subtotal | 94.79 |
| Additional [MJ/m2] | |
| Subtotal | 0.00 |
| Miscellaneous | 0.00 |
| Percent [%] | |
| Interior Lighting (All) | 4.90 |
| Space Heating | 0.00 |
| Space Cooling | 31.11 |
| Fans (All) | 11.28 |
| Service Water Heating | 19.96 |
| Receptacle Equipment | 30.50 |
| Miscellaneous | 2.25 |
| Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
| ELEVATOR_RUNNING_SCH | 146. | 3285. |
| ELEVATOR_STANDBY_SCH | 8201. | 8760. |
| OCC_APT_SCH_STAY_HOME_FAMILY | 5993. | 8760. |
| OCC_APT_SCH_CORRIDOR | 5993. | 8760. |
| OCC_APT_SCH_WORKING_FAMILY | 5845. | 6055. |
| OCC_OFF_SCH | 2210. | 2340. |
| OCC_OFF_W_SB_SCH | 1820. | 1820. |
| LTG_SCH_OFFICE | 2435. | 8760. |
| LTG_SCH_CORRIDOR | 6570. | 8760. |
| LTG_SCH_APARTMENT_HARDWIRED | 527. | 8760. |
| LTG_SCH_APARTMENT_PLUGIN | 527. | 8760. |
| EQP_APT_SCH | 5763. | 8760. |
| EQP_OFF_SCH | 3614. | 8760. |
| INF_APT_SCH | 8760. | 8760. |
| INF_OFF_SCH | 8760. | 8760. |
| INF_COR_SCH | 8760. | 8760. |
| INFIL_DOOR_OPENING_SCH | 1466. | 5840. |
| ALL OFF | 0. | 0. |
| ALL ON | 8760. | 8760. |
| ALWAYS_ON | 8760. | 8760. |
| ALLON_EXCEPT_DD | 8760. | 8760. |
| EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
| FAN_OFF_W_SB_SCH | 8240. | 8240. |
| APT_DHW_SCH | 4592. | 8760. |
| EXTERIOR_LTG_SCH | 4380. | 4380. |
| ELEV_LIGHT_FAN_SCH_24_7 | 8760. | 8760. |
| ELEV_LIGHT_FAN_SCH_ADD_DF | 2154. | 8760. |
| SLIDING_DOORS_VENTILATION_AVAILABILITY_SCH | 5840. | 5840. |
| First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
| HTGSETP_APT_SCH | APTHEATINGSETPOINT | January | 21.10 | 365 | 21.10 | 365 |
| HTGSETP_DESIGN_OFF_SCH | OFFHEATINGSETPOINT | January | 21.10 | 365 | 21.10 | 365 |
| CLGSETP_APT_SCH | APTCOOLINGSETPOINT | July | 24.00 | 365 | 24.00 | 365 |
| CLGSETP_DESIGN_OFF_SCH | OFFCOOLINGSETPOINT | July | 23.90 | 365 | 23.90 | 365 |
| S HTGSETP_APT_SCH | S APARTMENT DUAL SP CONTROL | January | 21.10 | 365 | 21.10 | 365 |
| S CLGSETP_APT_SCH | S APARTMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
| N HTGSETP_APT_SCH | N APARTMENT DUAL SP CONTROL | January | 21.10 | 365 | 21.10 | 365 |
| N CLGSETP_APT_SCH | N APARTMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
| HTGSETP_OFF_SCH_NO_OPTIMUM | OFFICE DUAL SP CONTROL | January | 21.10 | 365 | 15.60 | 365 |
| CLGSETP_OFF_SCH_NO_OPTIMUM | OFFICE DUAL SP CONTROL | July | 24.00 | 365 | 29.40 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
Heat Index Hours| Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| G SW APARTMENT | 8755.33 | 4.67 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 8757.17 | 2.83 | 0.00 | 0.00 | 0.00 |
| OFFICE | 2573.50 | 3377.67 | 2808.83 | 0.00 | 0.00 |
| G NE APARTMENT | 8751.33 | 8.67 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 8758.83 | 1.17 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 8758.83 | 1.17 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 8759.17 | 0.83 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 8755.67 | 4.33 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 8757.83 | 2.17 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 8759.50 | 0.50 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 8751.17 | 8.83 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 8752.50 | 7.50 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 8742.50 | 17.50 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 8738.67 | 21.33 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 8754.67 | 5.33 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 8754.50 | 5.50 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 8752.33 | 7.67 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 8752.67 | 7.33 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 128.83 | 6977.17 | 1654.00 | 0.00 | 0.00 |
| G CORRIDOR | 71.00 | 3541.00 | 5147.17 | 0.83 | 0.00 |
| M CORRIDOR | 0.00 | 8760.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 8760.00 | 8760.00 | 5147.17 | 0.83 | 0.00 |
| Average | 7560.96 | 843.08 | 355.93 | 0.03 | 0.00 |
| Sum | 204146.00 | 22763.17 | 9610.00 | 0.83 | 0.00 |
| Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| G SW APARTMENT | 11822.33 | 7.67 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 10580.67 | 4.33 | 0.00 | 0.00 | 0.00 |
| OFFICE | 7000.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 10580.00 | 5.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 10582.67 | 2.33 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 10582.67 | 2.33 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 11828.33 | 1.67 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 11822.50 | 7.50 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 11827.67 | 2.33 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 11816.17 | 13.83 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 10576.00 | 9.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 11806.83 | 23.17 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 10578.00 | 7.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 10579.00 | 6.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 10579.00 | 6.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 11818.17 | 11.83 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 11818.83 | 11.17 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 490.33 | 19500.83 | 3003.83 | 0.00 | 0.00 |
| G CORRIDOR | 194.50 | 7839.00 | 14959.83 | 1.67 | 0.00 |
| M CORRIDOR | 0.00 | 22995.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 11830.00 | 22995.00 | 14959.83 | 1.67 | 0.00 |
| Average | 9804.21 | 1868.74 | 665.32 | 0.06 | 0.00 |
| Sum | 264713.67 | 50456.00 | 17963.67 | 1.67 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| G SW APARTMENT | 7545.83 | 1214.17 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 7698.17 | 1061.83 | 0.00 | 0.00 | 0.00 |
| OFFICE | 2226.00 | 5067.83 | 1466.17 | 0.00 | 0.00 |
| G NE APARTMENT | 7729.33 | 1030.67 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 7131.67 | 1628.33 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 7133.00 | 1627.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 7271.67 | 1488.33 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 7917.00 | 843.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 6497.67 | 2262.33 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 6501.33 | 2258.67 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 6611.00 | 2149.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 6557.50 | 2202.50 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 5795.00 | 2965.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 5800.17 | 2959.83 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 5993.00 | 2767.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 6000.33 | 2759.67 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 5661.33 | 3098.67 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 5613.00 | 3147.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 5736.83 | 3023.17 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 5687.00 | 3073.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 5404.67 | 3355.33 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 5411.67 | 3348.33 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 5459.00 | 3301.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 5432.33 | 3327.67 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 0.00 | 4358.17 | 4401.83 | 0.00 | 0.00 |
| G CORRIDOR | 0.00 | 3808.50 | 4950.67 | 0.83 | 0.00 |
| M CORRIDOR | 0.00 | 6603.83 | 2156.17 | 0.00 | 0.00 |
| Min | 0.00 | 843.00 | 0.00 | 0.00 | 0.00 |
| Max | 7917.00 | 6603.83 | 4950.67 | 0.83 | 0.00 |
| Average | 5511.65 | 2767.77 | 480.55 | 0.03 | 0.00 |
| Sum | 148814.50 | 74729.83 | 12974.83 | 0.83 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| G SW APARTMENT | 9780.83 | 2049.17 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 8978.00 | 1607.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 6809.33 | 190.67 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 8919.33 | 1665.67 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 8088.00 | 2497.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 8084.33 | 2500.67 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 9340.83 | 2489.17 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 10410.00 | 1420.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 8112.50 | 3717.50 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 7214.33 | 3370.67 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 8062.00 | 3768.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 6956.17 | 3628.83 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 6275.33 | 4309.67 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 6268.17 | 4316.83 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 7373.67 | 4456.33 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 7377.50 | 4452.50 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 6561.33 | 5268.67 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 5654.83 | 4930.17 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 6438.33 | 5391.67 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 5403.17 | 5181.83 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 5412.17 | 5172.83 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 5401.50 | 5183.50 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 6300.83 | 5529.17 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 6245.17 | 5584.83 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 0.00 | 13598.50 | 9396.50 | 0.00 | 0.00 |
| G CORRIDOR | 0.00 | 8059.67 | 14934.33 | 1.00 | 0.00 |
| M CORRIDOR | 0.00 | 18996.83 | 3998.17 | 0.00 | 0.00 |
| Min | 0.00 | 190.67 | 0.00 | 0.00 | 0.00 |
| Max | 10410.00 | 18996.83 | 14934.33 | 1.00 | 0.00 |
| Average | 6498.80 | 4790.27 | 1049.22 | 0.04 | 0.00 |
| Sum | 175467.67 | 129337.33 | 28329.00 | 1.00 | 0.00 |
| SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
| None |
| SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
| None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
CO2 Level Hours| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:15
Illuminance Level Hours| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 0A
For: Environment
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 26.415 |
| February | 27.500 |
| March | 28.331 |
| April | 29.151 |
| May | 29.006 |
| June | 28.856 |
| July | 27.250 |
| August | 27.543 |
| September | 27.578 |
| October | 26.894 |
| November | 26.683 |
| December | 25.974 |
| Annual Sum or Average | 27.594 |
| Minimum of Months | 25.974 |
| Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 26.415 |
| February | 27.500 |
| March | 28.331 |
| April | 29.151 |
| May | 29.006 |
| June | 28.856 |
| July | 27.250 |
| August | 27.543 |
| September | 27.578 |
| October | 26.894 |
| November | 26.683 |
| December | 25.974 |
| Annual Sum or Average | 27.594 |
| Minimum of Months | 25.974 |
| Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
For: Environment
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 26.415 |
| February | 27.500 |
| March | 28.331 |
| April | 29.151 |
| May | 29.006 |
| June | 28.856 |
| July | 27.250 |
| August | 27.543 |
| September | 27.578 |
| October | 26.894 |
| November | 26.683 |
| December | 25.974 |
| Annual Sum or Average | 27.594 |
| Minimum of Months | 25.974 |
| Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2019
For: Environment
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 26.415 |
| February | 27.500 |
| March | 28.331 |
| April | 29.151 |
| May | 29.006 |
| June | 28.856 |
| July | 27.250 |
| August | 27.543 |
| September | 27.578 |
| October | 26.894 |
| November | 26.683 |
| December | 25.974 |
| Annual Sum or Average | 27.594 |
| Minimum of Months | 25.974 |
| Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE
For: Environment
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 26.415 |
| February | 27.500 |
| March | 28.331 |
| April | 29.151 |
| May | 29.006 |
| June | 28.856 |
| July | 27.250 |
| August | 27.543 |
| September | 27.578 |
| October | 26.894 |
| November | 26.683 |
| December | 25.974 |
| Annual Sum or Average | 27.594 |
| Minimum of Months | 25.974 |
| Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY VNM_HOCHIMINH_TANSONHOA
For: Environment
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 26.415 |
| February | 27.500 |
| March | 28.331 |
| April | 29.151 |
| May | 29.006 |
| June | 28.856 |
| July | 27.250 |
| August | 27.543 |
| September | 27.578 |
| October | 26.894 |
| November | 26.683 |
| December | 25.974 |
| Annual Sum or Average | 27.594 |
| Minimum of Months | 25.974 |
| Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 26.415 |
| February | 27.500 |
| March | 28.331 |
| April | 29.151 |
| May | 29.006 |
| June | 28.856 |
| July | 27.250 |
| August | 27.543 |
| September | 27.578 |
| October | 26.894 |
| November | 26.683 |
| December | 25.974 |
| Annual Sum or Average | 27.594 |
| Minimum of Months | 25.974 |
| Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PERFORMANCEPATHPROPOSED
For: Environment
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 26.415 |
| February | 27.500 |
| March | 28.331 |
| April | 29.151 |
| May | 29.006 |
| June | 28.856 |
| July | 27.250 |
| August | 27.543 |
| September | 27.578 |
| October | 26.894 |
| November | 26.683 |
| December | 25.974 |
| Annual Sum or Average | 27.594 |
| Minimum of Months | 25.974 |
| Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 26.415 |
| February | 27.500 |
| March | 28.331 |
| April | 29.151 |
| May | 29.006 |
| June | 28.856 |
| July | 27.250 |
| August | 27.543 |
| September | 27.578 |
| October | 26.894 |
| November | 26.683 |
| December | 25.974 |
| Annual Sum or Average | 27.594 |
| Minimum of Months | 25.974 |
| Maximum of Months | 29.151 |
Report: ZoneCoolingSummaryMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.356625E+10 | 4722.47 | 23-JAN-22:52 | 22.50 | 18.29 | 0.132850E+09 | 99.64 | 15-JAN-10:09 | 22.50 | 18.29 |
| February | 0.335417E+10 | 4538.28 | 21-FEB-11:02 | 30.33 | 21.90 | 0.117605E+09 | 97.57 | 25-FEB-07:00 | 27.00 | 20.22 |
| March | 0.361932E+10 | 4076.90 | 03-MAR-08:62 | 26.17 | 20.16 | 0.124335E+09 | 93.63 | 03-MAR-07:49 | 26.17 | 20.16 |
| April | 0.343728E+10 | 4093.06 | 14-APR-16:52 | 29.00 | 26.74 | 0.123963E+09 | 70.28 | 14-APR-17:19 | 29.03 | 26.72 |
| May | 0.352022E+10 | 3982.59 | 10-MAY-21:02 | 23.20 | 23.20 | 0.125953E+09 | 99.17 | 10-MAY-20:49 | 23.20 | 23.20 |
| June | 0.348993E+10 | 4083.86 | 24-JUN-19:52 | 24.00 | 24.00 | 0.120915E+09 | 99.51 | 25-JUN-19:00 | 23.00 | 23.00 |
| July | 0.331709E+10 | 4199.20 | 19-JUL-20:22 | 23.20 | 22.35 | 0.129969E+09 | 100.55 | 19-JUL-20:10 | 23.20 | 22.35 |
| August | 0.325952E+10 | 3946.85 | 21-AUG-12:02 | 27.07 | 24.82 | 0.124558E+09 | 99.48 | 23-AUG-20:00 | 23.00 | 23.00 |
| September | 0.327275E+10 | 4129.46 | 14-SEP-16:52 | 25.00 | 25.00 | 0.124524E+09 | 99.40 | 15-SEP-18:30 | 24.00 | 24.00 |
| October | 0.325042E+10 | 4271.59 | 09-OCT-19:42 | 23.93 | 23.23 | 0.128285E+09 | 97.46 | 30-OCT-19:19 | 23.73 | 23.28 |
| November | 0.333805E+10 | 4399.95 | 24-NOV-22:02 | 22.87 | 20.57 | 0.126379E+09 | 100.65 | 25-NOV-19:40 | 23.13 | 21.74 |
| December | 0.349232E+10 | 4783.27 | 20-DEC-21:32 | 22.33 | 18.33 | 0.133200E+09 | 100.25 | 26-DEC-22:10 | 23.08 | 19.87 |
| Annual Sum or Average | 0.409173E+11 | 0.151254E+10 | ||||||||
| Minimum of Months | 0.325042E+10 | 3946.85 | 22.33 | 18.29 | 0.117605E+09 | 70.28 | 22.50 | 18.29 | ||
| Maximum of Months | 0.361932E+10 | 4783.27 | 30.33 | 26.74 | 0.133200E+09 | 100.65 | 29.03 | 26.72 |
Report: ZoneCoolingSummaryMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.288583E+10 | 4670.18 | 23-JAN-22:52 | 22.50 | 18.29 | 0.131588E+09 | 90.36 | 23-JAN-22:00 | 22.50 | 18.29 |
| February | 0.284274E+10 | 4435.49 | 24-FEB-09:02 | 25.53 | 19.50 | 0.118575E+09 | 85.89 | 22-FEB-06:40 | 25.53 | 19.50 |
| March | 0.337299E+10 | 4061.57 | 03-MAR-08:62 | 26.17 | 20.16 | 0.129116E+09 | 86.60 | 03-MAR-06:00 | 26.17 | 20.16 |
| April | 0.348392E+10 | 4067.73 | 14-APR-16:52 | 29.00 | 26.74 | 0.124658E+09 | 70.27 | 01-APR-03:09 | 29.00 | 26.74 |
| May | 0.375278E+10 | 4024.95 | 10-MAY-21:02 | 23.20 | 23.20 | 0.128990E+09 | 100.27 | 10-MAY-20:49 | 23.20 | 23.20 |
| June | 0.389414E+10 | 4217.40 | 25-JUN-19:52 | 23.00 | 23.00 | 0.125121E+09 | 101.08 | 25-JUN-21:30 | 23.05 | 22.93 |
| July | 0.355975E+10 | 4403.59 | 19-JUL-19:52 | 23.10 | 22.37 | 0.129350E+09 | 98.54 | 19-JUL-20:00 | 23.30 | 22.32 |
| August | 0.339889E+10 | 3984.82 | 23-AUG-21:02 | 23.22 | 23.00 | 0.129259E+09 | 99.65 | 23-AUG-20:49 | 23.22 | 23.00 |
| September | 0.322092E+10 | 4091.08 | 14-SEP-16:52 | 25.00 | 25.00 | 0.125225E+09 | 98.16 | 15-SEP-20:40 | 23.10 | 23.10 |
| October | 0.300483E+10 | 4181.35 | 09-OCT-20:02 | 24.00 | 23.26 | 0.129602E+09 | 92.43 | 09-OCT-20:10 | 24.00 | 23.26 |
| November | 0.286648E+10 | 4313.40 | 25-NOV-20:02 | 23.00 | 21.65 | 0.126644E+09 | 96.14 | 25-NOV-21:19 | 22.90 | 21.68 |
| December | 0.281576E+10 | 4694.14 | 20-DEC-22:02 | 21.83 | 18.17 | 0.132051E+09 | 96.49 | 26-DEC-22:10 | 23.08 | 19.87 |
| Annual Sum or Average | 0.390990E+11 | 0.153018E+10 | ||||||||
| Minimum of Months | 0.281576E+10 | 3984.82 | 21.83 | 18.17 | 0.118575E+09 | 70.27 | 22.50 | 18.29 | ||
| Maximum of Months | 0.389414E+10 | 4694.14 | 29.00 | 26.74 | 0.132051E+09 | 101.08 | 29.00 | 26.74 |
Report: ZoneCoolingSummaryMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.238800E+10 | 5814.72 | 23-JAN-07:01 | 19.82 | 17.49 | 67296096.58 | 133.55 | 03-JAN-08:09 | 19.82 | 17.49 |
| February | 0.230631E+10 | 5357.68 | 24-FEB-07:01 | 21.42 | 18.05 | 63931319.86 | 133.54 | 07-FEB-16:49 | 21.42 | 18.05 |
| March | 0.258043E+10 | 4892.18 | 03-MAR-07:01 | 23.83 | 20.44 | 77389692.11 | 133.68 | 27-MAR-07:10 | 27.33 | 24.91 |
| April | 0.224362E+10 | 3858.45 | 03-APR-06:01 | 27.10 | 25.16 | 67295805.29 | 133.75 | 17-APR-07:10 | 27.75 | 25.60 |
| May | 0.243481E+10 | 3959.14 | 30-MAY-10:00 | 33.40 | 27.88 | 74033229.79 | 140.66 | 30-MAY-07:10 | 33.40 | 27.88 |
| June | 0.247261E+10 | 3957.18 | 19-JUN-10:00 | 33.40 | 27.88 | 74028497.22 | 136.12 | 12-JUN-07:10 | 33.40 | 27.88 |
| July | 0.211383E+10 | 4363.11 | 03-JUL-06:01 | 25.52 | 23.78 | 67292073.60 | 133.57 | 24-JUL-07:10 | 25.25 | 24.10 |
| August | 0.237927E+10 | 3796.61 | 28-AUG-09:50 | 30.92 | 26.75 | 77384027.50 | 133.66 | 15-AUG-07:10 | 30.92 | 26.75 |
| September | 0.214989E+10 | 3903.46 | 05-SEP-10:00 | 31.20 | 26.93 | 67291694.64 | 133.72 | 05-SEP-07:10 | 31.20 | 26.93 |
| October | 0.219108E+10 | 4003.54 | 10-OCT-06:01 | 23.95 | 23.25 | 70655171.97 | 133.68 | 16-OCT-07:10 | 27.33 | 26.08 |
| November | 0.224735E+10 | 4763.04 | 24-NOV-07:01 | 23.50 | 21.36 | 67293682.41 | 133.61 | 14-NOV-08:09 | 23.50 | 21.36 |
| December | 0.227229E+10 | 5200.28 | 21-DEC-07:01 | 18.83 | 17.79 | 67295217.58 | 133.54 | 11-DEC-08:50 | 18.83 | 17.79 |
| Annual Sum or Average | 0.277795E+11 | 0.841187E+09 | ||||||||
| Minimum of Months | 0.211383E+10 | 3796.61 | 18.83 | 17.49 | 63931319.86 | 133.54 | 18.83 | 17.49 | ||
| Maximum of Months | 0.258043E+10 | 5814.72 | 33.40 | 27.88 | 77389692.11 | 140.66 | 33.40 | 27.88 |
Report: ZoneCoolingSummaryMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.287272E+10 | 4467.26 | 23-JAN-22:52 | 22.50 | 18.29 | 0.131835E+09 | 90.52 | 23-JAN-22:00 | 22.50 | 18.29 |
| February | 0.284435E+10 | 4289.32 | 21-FEB-11:12 | 30.67 | 21.98 | 0.118760E+09 | 86.64 | 15-FEB-06:00 | 30.67 | 21.98 |
| March | 0.335457E+10 | 3898.79 | 03-MAR-08:62 | 26.17 | 20.16 | 0.129128E+09 | 87.10 | 03-MAR-06:00 | 26.17 | 20.16 |
| April | 0.349111E+10 | 3863.81 | 14-APR-16:52 | 29.00 | 26.74 | 0.124657E+09 | 70.27 | 01-APR-03:09 | 29.00 | 26.74 |
| May | 0.377560E+10 | 3813.97 | 10-MAY-21:02 | 23.20 | 23.20 | 0.128986E+09 | 99.28 | 10-MAY-20:49 | 23.20 | 23.20 |
| June | 0.392053E+10 | 3975.12 | 24-JUN-19:52 | 24.00 | 24.00 | 0.125122E+09 | 100.20 | 25-JUN-21:30 | 23.05 | 22.93 |
| July | 0.357388E+10 | 4130.57 | 19-JUL-19:52 | 23.10 | 22.37 | 0.129349E+09 | 97.12 | 19-JUL-20:00 | 23.30 | 22.32 |
| August | 0.342522E+10 | 3802.05 | 21-AUG-12:02 | 27.07 | 24.82 | 0.129260E+09 | 98.78 | 23-AUG-20:49 | 23.00 | 22.88 |
| September | 0.324905E+10 | 3907.99 | 14-SEP-16:52 | 25.00 | 25.00 | 0.125227E+09 | 98.15 | 15-SEP-20:40 | 23.10 | 23.10 |
| October | 0.301103E+10 | 3980.37 | 09-OCT-20:02 | 24.00 | 23.26 | 0.129608E+09 | 92.43 | 09-OCT-20:10 | 24.00 | 23.26 |
| November | 0.287471E+10 | 4117.93 | 25-NOV-20:02 | 23.00 | 21.65 | 0.126716E+09 | 96.44 | 25-NOV-21:19 | 22.90 | 21.68 |
| December | 0.280965E+10 | 4471.29 | 20-DEC-22:02 | 21.83 | 18.17 | 0.132279E+09 | 95.81 | 26-DEC-22:10 | 23.08 | 19.87 |
| Annual Sum or Average | 0.392024E+11 | 0.153093E+10 | ||||||||
| Minimum of Months | 0.280965E+10 | 3802.05 | 21.83 | 18.17 | 0.118760E+09 | 70.27 | 22.50 | 18.29 | ||
| Maximum of Months | 0.392053E+10 | 4471.29 | 30.67 | 26.74 | 0.132279E+09 | 100.20 | 30.67 | 26.74 |
Report: ZoneCoolingSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.239144E+10 | 4005.85 | 23-JAN-22:52 | 22.50 | 18.29 | 0.131499E+09 | 89.62 | 23-JAN-22:00 | 22.50 | 18.29 |
| February | 0.231227E+10 | 3797.57 | 24-FEB-09:02 | 25.53 | 19.50 | 0.118461E+09 | 85.09 | 15-FEB-06:00 | 25.53 | 19.50 |
| March | 0.268115E+10 | 3492.49 | 03-MAR-08:62 | 26.17 | 20.16 | 0.129101E+09 | 86.05 | 03-MAR-06:00 | 26.17 | 20.16 |
| April | 0.277604E+10 | 3421.56 | 14-APR-16:52 | 29.00 | 26.74 | 0.124654E+09 | 70.27 | 01-APR-05:19 | 29.00 | 26.74 |
| May | 0.308459E+10 | 3398.89 | 10-MAY-21:02 | 23.20 | 23.20 | 0.128973E+09 | 96.78 | 10-MAY-20:49 | 23.20 | 23.20 |
| June | 0.320127E+10 | 3552.52 | 24-JUN-19:52 | 24.00 | 24.00 | 0.125086E+09 | 97.97 | 25-JUN-21:30 | 23.05 | 22.93 |
| July | 0.296938E+10 | 3710.49 | 19-JUL-19:52 | 23.10 | 22.37 | 0.129311E+09 | 95.24 | 19-JUL-20:00 | 23.30 | 22.32 |
| August | 0.280627E+10 | 3348.55 | 04-AUG-13:52 | 24.00 | 24.00 | 0.129234E+09 | 95.58 | 23-AUG-20:49 | 23.00 | 22.88 |
| September | 0.264041E+10 | 3461.09 | 14-SEP-16:52 | 25.00 | 25.00 | 0.125193E+09 | 96.21 | 15-SEP-20:40 | 23.10 | 23.10 |
| October | 0.251366E+10 | 3531.54 | 09-OCT-20:02 | 24.00 | 23.26 | 0.129571E+09 | 92.43 | 09-OCT-20:10 | 24.00 | 23.26 |
| November | 0.240301E+10 | 3668.29 | 25-NOV-20:02 | 23.00 | 21.65 | 0.126570E+09 | 95.46 | 26-NOV-21:40 | 22.93 | 21.59 |
| December | 0.235884E+10 | 4021.52 | 20-DEC-22:02 | 21.83 | 18.17 | 0.131948E+09 | 93.94 | 26-DEC-22:10 | 23.08 | 19.87 |
| Annual Sum or Average | 0.321383E+11 | 0.152960E+10 | ||||||||
| Minimum of Months | 0.231227E+10 | 3348.55 | 21.83 | 18.17 | 0.118461E+09 | 70.27 | 22.50 | 18.29 | ||
| Maximum of Months | 0.320127E+10 | 4021.52 | 29.00 | 26.74 | 0.131948E+09 | 97.97 | 29.00 | 26.74 |
Report: ZoneCoolingSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.239261E+10 | 4002.19 | 23-JAN-22:52 | 22.50 | 18.29 | 0.131502E+09 | 89.64 | 23-JAN-22:00 | 22.50 | 18.29 |
| February | 0.231336E+10 | 3793.50 | 24-FEB-09:02 | 25.53 | 19.50 | 0.118463E+09 | 85.10 | 15-FEB-06:00 | 25.53 | 19.50 |
| March | 0.268076E+10 | 3488.56 | 03-MAR-08:62 | 26.17 | 20.16 | 0.129101E+09 | 86.05 | 03-MAR-06:00 | 26.17 | 20.16 |
| April | 0.277642E+10 | 3417.79 | 14-APR-16:52 | 29.00 | 26.74 | 0.124654E+09 | 70.27 | 01-APR-05:19 | 29.00 | 26.74 |
| May | 0.308546E+10 | 3394.15 | 10-MAY-21:02 | 23.20 | 23.20 | 0.128973E+09 | 96.73 | 10-MAY-20:49 | 23.20 | 23.20 |
| June | 0.320227E+10 | 3548.62 | 24-JUN-19:52 | 24.00 | 24.00 | 0.125086E+09 | 97.94 | 25-JUN-21:30 | 23.05 | 22.93 |
| July | 0.297008E+10 | 3705.00 | 19-JUL-19:52 | 23.10 | 22.37 | 0.129311E+09 | 95.15 | 19-JUL-20:00 | 23.30 | 22.32 |
| August | 0.280736E+10 | 3345.50 | 04-AUG-13:52 | 24.00 | 24.00 | 0.129234E+09 | 95.55 | 23-AUG-20:49 | 23.00 | 22.88 |
| September | 0.264164E+10 | 3457.52 | 14-SEP-16:52 | 25.00 | 25.00 | 0.125194E+09 | 96.21 | 15-SEP-20:40 | 23.10 | 23.10 |
| October | 0.251394E+10 | 3527.70 | 09-OCT-20:02 | 24.00 | 23.26 | 0.129571E+09 | 92.43 | 09-OCT-20:10 | 24.00 | 23.26 |
| November | 0.240374E+10 | 3664.68 | 25-NOV-20:02 | 23.00 | 21.65 | 0.126571E+09 | 95.47 | 26-NOV-21:40 | 22.93 | 21.59 |
| December | 0.235975E+10 | 4016.84 | 20-DEC-22:02 | 21.83 | 18.17 | 0.131950E+09 | 93.91 | 26-DEC-22:10 | 23.08 | 19.87 |
| Annual Sum or Average | 0.321474E+11 | 0.152961E+10 | ||||||||
| Minimum of Months | 0.231336E+10 | 3345.50 | 21.83 | 18.17 | 0.118463E+09 | 70.27 | 22.50 | 18.29 | ||
| Maximum of Months | 0.320227E+10 | 4016.84 | 29.00 | 26.74 | 0.131950E+09 | 97.94 | 29.00 | 26.74 |
Report: ZoneCoolingSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.309548E+10 | 4065.83 | 23-JAN-22:52 | 22.50 | 18.29 | 0.132801E+09 | 98.43 | 15-JAN-10:09 | 22.50 | 18.29 |
| February | 0.284367E+10 | 3884.43 | 21-FEB-11:02 | 30.33 | 21.90 | 0.117520E+09 | 96.03 | 25-FEB-07:00 | 27.00 | 20.22 |
| March | 0.294355E+10 | 3510.08 | 03-MAR-08:62 | 26.17 | 20.16 | 0.124322E+09 | 92.75 | 03-MAR-07:49 | 26.17 | 20.16 |
| April | 0.274055E+10 | 3439.31 | 14-APR-16:52 | 29.00 | 26.74 | 0.123963E+09 | 70.28 | 14-APR-17:19 | 29.03 | 26.72 |
| May | 0.286069E+10 | 3341.21 | 10-MAY-21:02 | 23.20 | 23.20 | 0.125933E+09 | 95.46 | 10-MAY-20:49 | 23.20 | 23.20 |
| June | 0.280175E+10 | 3475.74 | 24-JUN-19:52 | 24.00 | 24.00 | 0.120878E+09 | 96.05 | 25-JUN-21:30 | 23.05 | 22.93 |
| July | 0.273439E+10 | 3524.16 | 19-JUL-20:22 | 23.20 | 22.35 | 0.129918E+09 | 95.75 | 19-JUL-20:10 | 23.20 | 22.35 |
| August | 0.267546E+10 | 3354.28 | 21-AUG-12:02 | 27.07 | 24.82 | 0.124531E+09 | 95.81 | 19-AUG-19:40 | 27.07 | 24.82 |
| September | 0.270383E+10 | 3499.92 | 14-SEP-16:52 | 25.00 | 25.00 | 0.124497E+09 | 96.96 | 15-SEP-18:30 | 24.00 | 24.00 |
| October | 0.277536E+10 | 3631.73 | 09-OCT-19:42 | 23.93 | 23.23 | 0.128266E+09 | 96.67 | 30-OCT-19:19 | 23.73 | 23.28 |
| November | 0.289465E+10 | 3789.87 | 24-NOV-22:02 | 22.87 | 20.57 | 0.126323E+09 | 98.98 | 25-NOV-19:40 | 23.13 | 21.74 |
| December | 0.305933E+10 | 4130.00 | 20-DEC-21:32 | 22.33 | 18.33 | 0.133150E+09 | 98.26 | 26-DEC-22:10 | 23.08 | 19.87 |
| Annual Sum or Average | 0.341287E+11 | 0.151210E+10 | ||||||||
| Minimum of Months | 0.267546E+10 | 3341.21 | 22.33 | 18.29 | 0.117520E+09 | 70.28 | 22.50 | 18.29 | ||
| Maximum of Months | 0.309548E+10 | 4130.00 | 30.33 | 26.74 | 0.133150E+09 | 98.98 | 29.03 | 26.72 |
Report: ZoneCoolingSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.335420E+10 | 4149.21 | 23-JAN-22:52 | 22.50 | 18.29 | 0.133129E+09 | 100.81 | 15-JAN-10:09 | 22.50 | 18.29 |
| February | 0.307644E+10 | 4056.60 | 21-FEB-10:42 | 28.38 | 21.67 | 0.117716E+09 | 97.58 | 25-FEB-07:00 | 27.00 | 20.22 |
| March | 0.319965E+10 | 3579.79 | 03-MAR-08:62 | 26.17 | 20.16 | 0.124351E+09 | 94.13 | 03-MAR-07:49 | 26.17 | 20.16 |
| April | 0.300734E+10 | 3507.96 | 14-APR-16:52 | 29.00 | 26.74 | 0.123963E+09 | 70.28 | 14-APR-17:19 | 29.03 | 26.72 |
| May | 0.313738E+10 | 3420.91 | 10-MAY-21:02 | 23.20 | 23.20 | 0.125943E+09 | 97.02 | 10-MAY-20:49 | 23.20 | 23.20 |
| June | 0.306358E+10 | 3569.54 | 24-JUN-19:52 | 24.00 | 24.00 | 0.120913E+09 | 98.25 | 25-JUN-21:30 | 23.05 | 22.93 |
| July | 0.300271E+10 | 3595.45 | 19-JUL-20:22 | 23.20 | 22.35 | 0.129954E+09 | 97.41 | 17-JUL-19:49 | 23.20 | 22.35 |
| August | 0.292323E+10 | 3436.84 | 21-AUG-12:02 | 27.07 | 24.82 | 0.124570E+09 | 97.45 | 19-AUG-19:40 | 27.07 | 24.82 |
| September | 0.295956E+10 | 3565.84 | 14-SEP-16:52 | 25.00 | 25.00 | 0.124519E+09 | 98.06 | 15-SEP-18:30 | 24.00 | 24.00 |
| October | 0.303451E+10 | 3729.47 | 09-OCT-19:42 | 23.93 | 23.23 | 0.128323E+09 | 98.24 | 30-OCT-19:19 | 23.73 | 23.28 |
| November | 0.314170E+10 | 3846.84 | 24-NOV-22:02 | 22.87 | 20.57 | 0.126492E+09 | 101.01 | 25-NOV-19:40 | 23.13 | 21.74 |
| December | 0.329574E+10 | 4173.00 | 20-DEC-21:32 | 22.33 | 18.33 | 0.133431E+09 | 100.01 | 26-DEC-22:10 | 23.08 | 19.87 |
| Annual Sum or Average | 0.371960E+11 | 0.151330E+10 | ||||||||
| Minimum of Months | 0.292323E+10 | 3420.91 | 22.33 | 18.29 | 0.117716E+09 | 70.28 | 22.50 | 18.29 | ||
| Maximum of Months | 0.335420E+10 | 4173.00 | 29.00 | 26.74 | 0.133431E+09 | 101.01 | 29.03 | 26.72 |
Report: ZoneCoolingSummaryMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.348204E+10 | 5017.57 | 23-JAN-22:52 | 22.50 | 18.29 | 0.132221E+09 | 96.12 | 22-JAN-10:00 | 22.50 | 18.29 |
| February | 0.326243E+10 | 4861.39 | 21-FEB-11:02 | 30.33 | 21.90 | 0.117164E+09 | 93.02 | 25-FEB-07:00 | 27.00 | 20.22 |
| March | 0.353055E+10 | 4292.85 | 03-MAR-08:62 | 26.17 | 20.16 | 0.124268E+09 | 90.75 | 03-MAR-07:00 | 26.17 | 20.16 |
| April | 0.331885E+10 | 4349.52 | 14-APR-16:52 | 29.00 | 26.74 | 0.123963E+09 | 70.28 | 14-APR-17:19 | 29.03 | 26.72 |
| May | 0.332523E+10 | 4224.53 | 10-MAY-21:02 | 23.20 | 23.20 | 0.125932E+09 | 94.98 | 10-MAY-20:49 | 23.20 | 23.20 |
| June | 0.325316E+10 | 4307.02 | 24-JUN-19:52 | 24.00 | 24.00 | 0.120847E+09 | 95.78 | 25-JUN-19:00 | 23.00 | 23.00 |
| July | 0.304243E+10 | 4434.12 | 19-JUL-20:22 | 23.20 | 22.35 | 0.129868E+09 | 96.54 | 19-JUL-20:10 | 23.20 | 22.35 |
| August | 0.299128E+10 | 4133.87 | 21-AUG-12:02 | 27.07 | 24.82 | 0.124465E+09 | 95.06 | 23-AUG-20:00 | 23.00 | 23.00 |
| September | 0.302457E+10 | 4327.81 | 14-SEP-16:52 | 25.00 | 25.00 | 0.124462E+09 | 94.70 | 15-SEP-18:30 | 24.00 | 24.00 |
| October | 0.309857E+10 | 4542.04 | 09-OCT-19:42 | 23.93 | 23.23 | 0.128180E+09 | 93.93 | 30-OCT-19:19 | 23.73 | 23.28 |
| November | 0.319672E+10 | 4701.65 | 24-NOV-22:02 | 22.87 | 20.57 | 0.126060E+09 | 96.91 | 25-NOV-19:40 | 23.13 | 21.74 |
| December | 0.336492E+10 | 5153.56 | 20-DEC-21:32 | 22.33 | 18.33 | 0.132507E+09 | 95.98 | 26-DEC-22:10 | 23.08 | 19.87 |
| Annual Sum or Average | 0.388908E+11 | 0.150994E+10 | ||||||||
| Minimum of Months | 0.299128E+10 | 4133.87 | 22.33 | 18.29 | 0.117164E+09 | 70.28 | 22.50 | 18.29 | ||
| Maximum of Months | 0.353055E+10 | 5153.56 | 30.33 | 26.74 | 0.132507E+09 | 96.91 | 29.03 | 26.72 |
Report: ZoneCoolingSummaryMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.275709E+10 | 4974.24 | 23-JAN-22:52 | 22.50 | 18.29 | 0.131020E+09 | 87.89 | 23-JAN-22:00 | 22.50 | 18.29 |
| February | 0.272292E+10 | 4722.96 | 24-FEB-09:02 | 25.53 | 19.50 | 0.118158E+09 | 83.19 | 15-FEB-06:00 | 25.53 | 19.50 |
| March | 0.327063E+10 | 4265.79 | 03-MAR-08:62 | 26.17 | 20.16 | 0.129054E+09 | 83.53 | 05-MAR-06:00 | 24.30 | 22.12 |
| April | 0.335786E+10 | 4333.60 | 14-APR-16:52 | 29.00 | 26.74 | 0.124656E+09 | 70.27 | 01-APR-03:20 | 29.00 | 26.74 |
| May | 0.355664E+10 | 4277.08 | 10-MAY-21:02 | 23.20 | 23.20 | 0.128971E+09 | 95.98 | 10-MAY-20:49 | 23.20 | 23.20 |
| June | 0.366246E+10 | 4447.21 | 25-JUN-19:52 | 23.00 | 23.00 | 0.125054E+09 | 96.76 | 25-JUN-21:19 | 23.03 | 22.95 |
| July | 0.328148E+10 | 4669.31 | 19-JUL-19:52 | 23.10 | 22.37 | 0.129271E+09 | 95.62 | 19-JUL-20:00 | 23.30 | 22.32 |
| August | 0.312568E+10 | 4155.81 | 23-AUG-21:02 | 23.22 | 23.00 | 0.129184E+09 | 95.41 | 23-AUG-20:49 | 23.22 | 23.00 |
| September | 0.295996E+10 | 4297.51 | 14-SEP-16:52 | 25.00 | 25.00 | 0.125149E+09 | 93.78 | 15-SEP-20:40 | 23.10 | 23.10 |
| October | 0.283318E+10 | 4440.49 | 09-OCT-20:02 | 24.00 | 23.26 | 0.129488E+09 | 92.43 | 09-OCT-20:10 | 24.00 | 23.26 |
| November | 0.269389E+10 | 4602.68 | 25-NOV-20:02 | 23.00 | 21.65 | 0.126343E+09 | 93.08 | 25-NOV-21:19 | 22.90 | 21.68 |
| December | 0.264524E+10 | 4965.92 | 20-DEC-22:02 | 21.83 | 18.17 | 0.131375E+09 | 92.39 | 26-DEC-22:10 | 23.08 | 19.87 |
| Annual Sum or Average | 0.368670E+11 | 0.152772E+10 | ||||||||
| Minimum of Months | 0.264524E+10 | 4155.81 | 21.83 | 18.17 | 0.118158E+09 | 70.27 | 22.50 | 18.29 | ||
| Maximum of Months | 0.366246E+10 | 4974.24 | 29.00 | 26.74 | 0.131375E+09 | 96.76 | 29.00 | 26.74 |
Report: ZoneCoolingSummaryMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.346873E+10 | 4774.65 | 23-JAN-22:52 | 22.50 | 18.29 | 0.132502E+09 | 100.69 | 22-JAN-10:00 | 22.50 | 18.29 |
| February | 0.326530E+10 | 5000.18 | 21-FEB-10:42 | 28.38 | 21.67 | 0.117369E+09 | 95.92 | 25-FEB-07:00 | 27.00 | 20.22 |
| March | 0.350888E+10 | 4119.57 | 03-MAR-08:62 | 26.17 | 20.16 | 0.124287E+09 | 92.42 | 03-MAR-07:00 | 26.17 | 20.16 |
| April | 0.332589E+10 | 4084.26 | 14-APR-16:52 | 29.00 | 26.74 | 0.123963E+09 | 70.28 | 14-APR-17:19 | 29.03 | 26.72 |
| May | 0.335014E+10 | 3943.96 | 10-MAY-21:02 | 23.20 | 23.20 | 0.125926E+09 | 93.81 | 10-MAY-20:49 | 23.20 | 23.20 |
| June | 0.328349E+10 | 4092.36 | 24-JUN-19:52 | 24.00 | 24.00 | 0.120845E+09 | 93.97 | 25-JUN-19:00 | 23.00 | 23.00 |
| July | 0.305896E+10 | 4102.40 | 19-JUL-20:22 | 23.20 | 22.35 | 0.129867E+09 | 94.14 | 19-JUL-20:10 | 23.20 | 22.35 |
| August | 0.302140E+10 | 4003.89 | 21-AUG-12:02 | 27.07 | 24.82 | 0.124465E+09 | 93.94 | 23-AUG-20:00 | 23.00 | 23.00 |
| September | 0.305526E+10 | 4116.76 | 14-SEP-16:52 | 25.00 | 25.00 | 0.124460E+09 | 94.49 | 15-SEP-18:30 | 24.00 | 24.00 |
| October | 0.310648E+10 | 4298.49 | 09-OCT-19:42 | 23.93 | 23.23 | 0.128187E+09 | 94.10 | 30-OCT-19:19 | 23.73 | 23.28 |
| November | 0.320457E+10 | 4458.89 | 25-NOV-19:52 | 23.00 | 21.65 | 0.126161E+09 | 100.19 | 25-NOV-09:50 | 23.00 | 21.65 |
| December | 0.335968E+10 | 4888.39 | 20-DEC-21:32 | 22.33 | 18.33 | 0.132773E+09 | 99.22 | 16-DEC-09:30 | 22.33 | 18.33 |
| Annual Sum or Average | 0.390088E+11 | 0.151081E+10 | ||||||||
| Minimum of Months | 0.302140E+10 | 3943.96 | 22.33 | 18.29 | 0.117369E+09 | 70.28 | 22.33 | 18.29 | ||
| Maximum of Months | 0.350888E+10 | 5000.18 | 29.00 | 26.74 | 0.132773E+09 | 100.69 | 29.03 | 26.72 |
Report: ZoneCoolingSummaryMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.274064E+10 | 4738.87 | 23-JAN-22:52 | 22.50 | 18.29 | 0.131314E+09 | 88.16 | 23-JAN-22:00 | 22.50 | 18.29 |
| February | 0.272401E+10 | 4579.00 | 21-FEB-11:12 | 30.67 | 21.98 | 0.118386E+09 | 84.21 | 15-FEB-06:00 | 30.67 | 21.98 |
| March | 0.324893E+10 | 4108.92 | 03-MAR-08:62 | 26.17 | 20.16 | 0.129072E+09 | 84.59 | 05-MAR-06:00 | 24.30 | 22.12 |
| April | 0.336489E+10 | 4071.51 | 14-APR-16:52 | 29.00 | 26.74 | 0.124654E+09 | 70.27 | 29-APR-05:00 | 27.00 | 25.53 |
| May | 0.358166E+10 | 4030.95 | 10-MAY-21:02 | 23.20 | 23.20 | 0.128966E+09 | 95.02 | 10-MAY-20:49 | 23.20 | 23.20 |
| June | 0.369292E+10 | 4178.22 | 24-JUN-19:52 | 24.00 | 24.00 | 0.125054E+09 | 95.67 | 25-JUN-21:19 | 23.03 | 22.95 |
| July | 0.329797E+10 | 4345.64 | 19-JUL-19:52 | 23.10 | 22.37 | 0.129273E+09 | 93.91 | 19-JUL-20:00 | 23.30 | 22.32 |
| August | 0.315594E+10 | 3998.48 | 21-AUG-12:02 | 27.07 | 24.82 | 0.129184E+09 | 94.17 | 23-AUG-20:49 | 23.00 | 22.88 |
| September | 0.299068E+10 | 4087.32 | 14-SEP-16:52 | 25.00 | 25.00 | 0.125151E+09 | 93.67 | 15-SEP-20:40 | 23.10 | 23.10 |
| October | 0.284090E+10 | 4187.69 | 09-OCT-20:02 | 24.00 | 23.26 | 0.129495E+09 | 92.43 | 09-OCT-20:10 | 24.00 | 23.26 |
| November | 0.270163E+10 | 4373.92 | 25-NOV-20:02 | 23.00 | 21.65 | 0.126433E+09 | 93.37 | 25-NOV-21:19 | 22.90 | 21.68 |
| December | 0.263791E+10 | 4703.26 | 20-DEC-22:02 | 21.83 | 18.17 | 0.131658E+09 | 91.79 | 20-DEC-22:10 | 21.83 | 18.17 |
| Annual Sum or Average | 0.369781E+11 | 0.152864E+10 | ||||||||
| Minimum of Months | 0.263791E+10 | 3998.48 | 21.83 | 18.17 | 0.118386E+09 | 70.27 | 21.83 | 18.17 | ||
| Maximum of Months | 0.369292E+10 | 4738.87 | 30.67 | 26.74 | 0.131658E+09 | 95.67 | 30.67 | 25.53 |
Report: ZoneCoolingSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.224385E+10 | 4255.57 | 23-JAN-22:52 | 22.50 | 18.29 | 0.130998E+09 | 87.08 | 23-JAN-22:00 | 22.50 | 18.29 |
| February | 0.216830E+10 | 4023.56 | 24-FEB-09:02 | 25.53 | 19.50 | 0.118092E+09 | 82.85 | 15-FEB-06:00 | 25.53 | 19.50 |
| March | 0.253137E+10 | 3660.01 | 03-MAR-08:62 | 26.17 | 20.16 | 0.129046E+09 | 83.14 | 03-MAR-06:00 | 26.17 | 20.16 |
| April | 0.260807E+10 | 3595.38 | 14-APR-16:52 | 29.00 | 26.74 | 0.124651E+09 | 70.27 | 29-APR-05:30 | 27.00 | 25.53 |
| May | 0.287137E+10 | 3557.21 | 10-MAY-21:02 | 23.20 | 23.20 | 0.128952E+09 | 92.52 | 10-MAY-20:49 | 23.20 | 23.20 |
| June | 0.296703E+10 | 3744.55 | 24-JUN-19:52 | 24.00 | 24.00 | 0.125023E+09 | 93.95 | 25-JUN-21:30 | 23.05 | 22.93 |
| July | 0.271907E+10 | 3901.14 | 19-JUL-19:52 | 23.10 | 22.37 | 0.129240E+09 | 92.44 | 17-JUL-20:10 | 23.10 | 22.37 |
| August | 0.255673E+10 | 3493.80 | 21-AUG-12:02 | 27.07 | 24.82 | 0.129164E+09 | 92.43 | 23-AUG-21:10 | 23.22 | 23.00 |
| September | 0.240183E+10 | 3605.03 | 14-SEP-16:52 | 25.00 | 25.00 | 0.125122E+09 | 92.42 | 15-SEP-20:00 | 23.00 | 23.00 |
| October | 0.233950E+10 | 3729.53 | 09-OCT-20:02 | 24.00 | 23.26 | 0.129469E+09 | 92.43 | 09-OCT-20:10 | 24.00 | 23.26 |
| November | 0.223014E+10 | 3893.54 | 25-NOV-20:02 | 23.00 | 21.65 | 0.126297E+09 | 92.44 | 26-NOV-21:00 | 22.90 | 21.56 |
| December | 0.219000E+10 | 4234.39 | 20-DEC-22:02 | 21.83 | 18.17 | 0.131349E+09 | 90.81 | 20-DEC-22:10 | 21.83 | 18.17 |
| Annual Sum or Average | 0.298272E+11 | 0.152740E+10 | ||||||||
| Minimum of Months | 0.216830E+10 | 3493.80 | 21.83 | 18.17 | 0.118092E+09 | 70.27 | 21.83 | 18.17 | ||
| Maximum of Months | 0.296703E+10 | 4255.57 | 29.00 | 26.74 | 0.131349E+09 | 93.95 | 27.00 | 25.53 |
Report: ZoneCoolingSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.224560E+10 | 4251.57 | 23-JAN-22:52 | 22.50 | 18.29 | 0.131002E+09 | 87.11 | 23-JAN-22:00 | 22.50 | 18.29 |
| February | 0.216982E+10 | 4021.22 | 24-FEB-09:02 | 25.53 | 19.50 | 0.118095E+09 | 82.85 | 15-FEB-06:00 | 25.53 | 19.50 |
| March | 0.253105E+10 | 3656.03 | 03-MAR-08:62 | 26.17 | 20.16 | 0.129046E+09 | 83.13 | 03-MAR-06:00 | 26.17 | 20.16 |
| April | 0.260848E+10 | 3590.78 | 14-APR-16:52 | 29.00 | 26.74 | 0.124651E+09 | 70.27 | 29-APR-05:00 | 27.00 | 25.53 |
| May | 0.287225E+10 | 3551.45 | 10-MAY-21:02 | 23.20 | 23.20 | 0.128952E+09 | 92.48 | 10-MAY-20:49 | 23.20 | 23.20 |
| June | 0.296810E+10 | 3740.22 | 24-JUN-19:52 | 24.00 | 24.00 | 0.125023E+09 | 93.90 | 25-JUN-21:30 | 23.05 | 22.93 |
| July | 0.271980E+10 | 3894.66 | 19-JUL-19:52 | 23.10 | 22.37 | 0.129240E+09 | 92.44 | 17-JUL-20:10 | 23.10 | 22.37 |
| August | 0.255786E+10 | 3491.30 | 21-AUG-12:02 | 27.07 | 24.82 | 0.129164E+09 | 92.43 | 23-AUG-21:10 | 23.22 | 23.00 |
| September | 0.240302E+10 | 3601.53 | 14-SEP-16:52 | 25.00 | 25.00 | 0.125122E+09 | 92.42 | 15-SEP-20:00 | 23.00 | 23.00 |
| October | 0.233986E+10 | 3725.12 | 09-OCT-20:02 | 24.00 | 23.26 | 0.129469E+09 | 92.43 | 09-OCT-20:10 | 24.00 | 23.26 |
| November | 0.223099E+10 | 3889.66 | 25-NOV-20:02 | 23.00 | 21.65 | 0.126298E+09 | 92.45 | 26-NOV-21:00 | 22.90 | 21.56 |
| December | 0.219145E+10 | 4229.05 | 20-DEC-22:02 | 21.83 | 18.17 | 0.131353E+09 | 90.80 | 20-DEC-22:10 | 21.83 | 18.17 |
| Annual Sum or Average | 0.298383E+11 | 0.152741E+10 | ||||||||
| Minimum of Months | 0.216982E+10 | 3491.30 | 21.83 | 18.17 | 0.118095E+09 | 70.27 | 21.83 | 18.17 | ||
| Maximum of Months | 0.296810E+10 | 4251.57 | 29.00 | 26.74 | 0.131353E+09 | 93.90 | 27.00 | 25.53 |
Report: ZoneCoolingSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.297525E+10 | 4308.90 | 23-JAN-22:52 | 22.50 | 18.29 | 0.132229E+09 | 95.28 | 15-JAN-10:09 | 22.50 | 18.29 |
| February | 0.271255E+10 | 4142.06 | 21-FEB-11:02 | 30.33 | 21.90 | 0.117118E+09 | 92.43 | 25-FEB-08:20 | 26.33 | 20.04 |
| March | 0.279364E+10 | 3686.12 | 03-MAR-08:62 | 26.17 | 20.16 | 0.124261E+09 | 89.96 | 03-MAR-07:00 | 26.17 | 20.16 |
| April | 0.256924E+10 | 3603.55 | 14-APR-16:52 | 29.00 | 26.74 | 0.123963E+09 | 70.28 | 14-APR-17:19 | 29.03 | 26.72 |
| May | 0.263852E+10 | 3485.35 | 10-MAY-21:02 | 23.20 | 23.20 | 0.125908E+09 | 92.34 | 10-MAY-21:10 | 23.20 | 23.20 |
| June | 0.255494E+10 | 3644.84 | 24-JUN-19:52 | 24.00 | 24.00 | 0.120813E+09 | 92.43 | 25-JUN-20:19 | 23.00 | 23.00 |
| July | 0.247806E+10 | 3583.65 | 19-JUL-20:22 | 23.20 | 22.35 | 0.129821E+09 | 92.22 | 17-JUL-20:10 | 23.20 | 22.35 |
| August | 0.242138E+10 | 3499.94 | 21-AUG-12:02 | 27.07 | 24.82 | 0.124442E+09 | 92.12 | 23-AUG-21:10 | 23.22 | 23.00 |
| September | 0.246681E+10 | 3636.81 | 14-SEP-16:52 | 25.00 | 25.00 | 0.124436E+09 | 92.56 | 15-SEP-18:30 | 24.00 | 24.00 |
| October | 0.260737E+10 | 3834.90 | 09-OCT-19:42 | 23.93 | 23.23 | 0.128168E+09 | 93.36 | 30-OCT-19:19 | 23.73 | 23.28 |
| November | 0.273813E+10 | 4030.74 | 24-NOV-22:02 | 22.87 | 20.57 | 0.126029E+09 | 95.38 | 25-NOV-19:40 | 23.13 | 21.74 |
| December | 0.291834E+10 | 4435.97 | 20-DEC-21:32 | 22.33 | 18.33 | 0.132524E+09 | 94.55 | 16-DEC-09:30 | 22.33 | 18.33 |
| Annual Sum or Average | 0.318742E+11 | 0.150971E+10 | ||||||||
| Minimum of Months | 0.242138E+10 | 3485.35 | 22.33 | 18.29 | 0.117118E+09 | 70.28 | 22.33 | 18.29 | ||
| Maximum of Months | 0.297525E+10 | 4435.97 | 30.33 | 26.74 | 0.132524E+09 | 95.38 | 29.03 | 26.72 |
Report: ZoneCoolingSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.297649E+10 | 4304.50 | 23-JAN-22:52 | 22.50 | 18.29 | 0.132232E+09 | 95.37 | 15-JAN-10:09 | 22.50 | 18.29 |
| February | 0.271385E+10 | 4138.99 | 21-FEB-11:02 | 30.33 | 21.90 | 0.117120E+09 | 92.43 | 25-FEB-08:20 | 26.33 | 20.04 |
| March | 0.279332E+10 | 3682.17 | 03-MAR-08:62 | 26.17 | 20.16 | 0.124261E+09 | 89.99 | 03-MAR-07:00 | 26.17 | 20.16 |
| April | 0.256965E+10 | 3599.02 | 14-APR-16:52 | 29.00 | 26.74 | 0.123963E+09 | 70.28 | 14-APR-17:19 | 29.03 | 26.72 |
| May | 0.263941E+10 | 3479.12 | 10-MAY-21:02 | 23.20 | 23.20 | 0.125908E+09 | 92.29 | 10-MAY-21:10 | 23.20 | 23.20 |
| June | 0.255602E+10 | 3640.78 | 24-JUN-19:52 | 24.00 | 24.00 | 0.120813E+09 | 92.43 | 25-JUN-20:19 | 23.00 | 23.00 |
| July | 0.247879E+10 | 3576.61 | 19-JUL-20:22 | 23.20 | 22.35 | 0.129821E+09 | 92.24 | 17-JUL-20:10 | 23.20 | 22.35 |
| August | 0.242251E+10 | 3497.85 | 21-AUG-12:02 | 27.07 | 24.82 | 0.124443E+09 | 92.08 | 23-AUG-21:10 | 23.22 | 23.00 |
| September | 0.246800E+10 | 3633.34 | 14-SEP-16:52 | 25.00 | 25.00 | 0.124436E+09 | 92.55 | 15-SEP-18:30 | 24.00 | 24.00 |
| October | 0.260774E+10 | 3830.38 | 09-OCT-19:42 | 23.93 | 23.23 | 0.128168E+09 | 93.37 | 30-OCT-19:19 | 23.73 | 23.28 |
| November | 0.273890E+10 | 4025.84 | 24-NOV-22:02 | 22.87 | 20.57 | 0.126030E+09 | 95.41 | 25-NOV-19:40 | 23.13 | 21.74 |
| December | 0.291950E+10 | 4430.54 | 20-DEC-21:32 | 22.33 | 18.33 | 0.132527E+09 | 94.63 | 16-DEC-09:30 | 22.33 | 18.33 |
| Annual Sum or Average | 0.318842E+11 | 0.150972E+10 | ||||||||
| Minimum of Months | 0.242251E+10 | 3479.12 | 22.33 | 18.29 | 0.117120E+09 | 70.28 | 22.33 | 18.29 | ||
| Maximum of Months | 0.297649E+10 | 4430.54 | 30.33 | 26.74 | 0.132527E+09 | 95.41 | 29.03 | 26.72 |
Report: ZoneCoolingSummaryMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.370677E+10 | 5309.27 | 23-JAN-22:52 | 22.50 | 18.29 | 0.131879E+09 | 103.99 | 22-JAN-10:00 | 22.50 | 18.29 |
| February | 0.350188E+10 | 5528.45 | 21-FEB-10:42 | 28.38 | 21.67 | 0.116942E+09 | 94.00 | 25-FEB-07:00 | 27.00 | 20.22 |
| March | 0.387695E+10 | 4454.62 | 03-MAR-08:62 | 26.17 | 20.16 | 0.124236E+09 | 91.99 | 03-MAR-07:00 | 26.17 | 20.16 |
| April | 0.370099E+10 | 4594.88 | 14-APR-16:52 | 29.00 | 26.74 | 0.123963E+09 | 70.28 | 14-APR-17:19 | 29.03 | 26.72 |
| May | 0.368450E+10 | 4553.68 | 10-MAY-21:02 | 23.20 | 23.20 | 0.125952E+09 | 101.04 | 10-MAY-20:49 | 23.20 | 23.20 |
| June | 0.361515E+10 | 4809.13 | 25-JUN-19:52 | 23.00 | 23.00 | 0.120872E+09 | 102.80 | 25-JUN-19:00 | 23.00 | 23.00 |
| July | 0.330968E+10 | 4781.49 | 19-JUL-20:22 | 23.20 | 22.35 | 0.129907E+09 | 105.79 | 19-JUL-20:10 | 23.20 | 22.35 |
| August | 0.323909E+10 | 4541.89 | 21-AUG-12:02 | 27.07 | 24.82 | 0.124504E+09 | 102.26 | 23-AUG-20:00 | 23.00 | 23.00 |
| September | 0.330189E+10 | 4569.86 | 14-SEP-16:52 | 25.00 | 25.00 | 0.124517E+09 | 102.27 | 15-SEP-18:30 | 24.00 | 24.00 |
| October | 0.331001E+10 | 4873.64 | 09-OCT-19:42 | 23.93 | 23.23 | 0.128199E+09 | 98.13 | 30-OCT-19:19 | 23.73 | 23.28 |
| November | 0.339680E+10 | 5027.25 | 25-NOV-19:52 | 23.00 | 21.65 | 0.126037E+09 | 102.33 | 25-NOV-09:50 | 23.00 | 21.65 |
| December | 0.354959E+10 | 5452.45 | 20-DEC-21:32 | 22.33 | 18.33 | 0.132165E+09 | 98.96 | 16-DEC-09:30 | 22.33 | 18.33 |
| Annual Sum or Average | 0.421933E+11 | 0.150917E+10 | ||||||||
| Minimum of Months | 0.323909E+10 | 4454.62 | 22.33 | 18.29 | 0.116942E+09 | 70.28 | 22.33 | 18.29 | ||
| Maximum of Months | 0.387695E+10 | 5528.45 | 29.00 | 26.74 | 0.132165E+09 | 105.79 | 29.03 | 26.72 |
Report: ZoneCoolingSummaryMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.294507E+10 | 5307.42 | 23-JAN-22:52 | 22.50 | 18.29 | 0.130706E+09 | 89.23 | 23-JAN-22:00 | 22.50 | 18.29 |
| February | 0.293808E+10 | 5007.60 | 21-FEB-11:12 | 30.67 | 21.98 | 0.117992E+09 | 81.62 | 15-FEB-06:00 | 30.67 | 21.98 |
| March | 0.360821E+10 | 4467.09 | 03-MAR-08:62 | 26.17 | 20.16 | 0.129028E+09 | 81.99 | 05-MAR-06:00 | 24.30 | 22.12 |
| April | 0.374504E+10 | 4596.34 | 14-APR-16:52 | 29.00 | 26.74 | 0.124658E+09 | 70.27 | 20-APR-20:00 | 28.00 | 25.79 |
| May | 0.393131E+10 | 4632.77 | 10-MAY-21:02 | 23.20 | 23.20 | 0.128990E+09 | 102.10 | 10-MAY-20:49 | 23.20 | 23.20 |
| June | 0.404722E+10 | 4823.87 | 25-JUN-19:52 | 23.00 | 23.00 | 0.125077E+09 | 104.15 | 25-JUN-21:30 | 23.05 | 22.93 |
| July | 0.356092E+10 | 5045.30 | 19-JUL-19:52 | 23.10 | 22.37 | 0.129299E+09 | 101.82 | 19-JUL-20:00 | 23.30 | 22.32 |
| August | 0.338145E+10 | 4580.46 | 21-AUG-12:02 | 27.07 | 24.82 | 0.129214E+09 | 102.01 | 23-AUG-20:49 | 23.00 | 22.88 |
| September | 0.323311E+10 | 4567.62 | 14-SEP-16:52 | 25.00 | 25.00 | 0.125209E+09 | 100.33 | 15-SEP-20:40 | 23.10 | 23.10 |
| October | 0.303315E+10 | 4798.57 | 09-OCT-20:02 | 24.00 | 23.26 | 0.129529E+09 | 92.43 | 09-OCT-20:10 | 24.00 | 23.26 |
| November | 0.286923E+10 | 4935.05 | 25-NOV-20:02 | 23.00 | 21.65 | 0.126342E+09 | 97.50 | 25-NOV-21:19 | 22.90 | 21.68 |
| December | 0.279304E+10 | 5362.00 | 20-DEC-22:02 | 21.83 | 18.17 | 0.131076E+09 | 96.32 | 20-DEC-21:49 | 21.83 | 18.17 |
| Annual Sum or Average | 0.400858E+11 | 0.152712E+10 | ||||||||
| Minimum of Months | 0.279304E+10 | 4467.09 | 21.83 | 18.17 | 0.117992E+09 | 70.27 | 21.83 | 18.17 | ||
| Maximum of Months | 0.404722E+10 | 5362.00 | 30.67 | 26.74 | 0.131076E+09 | 104.15 | 30.67 | 25.79 |
Report: ZoneCoolingSummaryMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.368708E+10 | 5154.37 | 31-JAN-10:32 | 27.67 | 22.48 | 0.132306E+09 | 112.88 | 22-JAN-09:00 | 27.67 | 22.48 |
| February | 0.350223E+10 | 5524.24 | 21-FEB-10:42 | 28.38 | 21.67 | 0.117234E+09 | 99.47 | 25-FEB-07:00 | 27.00 | 20.22 |
| March | 0.384913E+10 | 4203.98 | 03-MAR-08:62 | 26.17 | 20.16 | 0.124263E+09 | 93.92 | 03-MAR-07:49 | 26.17 | 20.16 |
| April | 0.370674E+10 | 4218.66 | 14-APR-16:52 | 29.00 | 26.74 | 0.123963E+09 | 70.28 | 14-APR-17:19 | 29.03 | 26.72 |
| May | 0.371196E+10 | 4178.76 | 10-MAY-21:02 | 23.20 | 23.20 | 0.125944E+09 | 99.66 | 10-MAY-20:49 | 23.20 | 23.20 |
| June | 0.365211E+10 | 4292.23 | 30-JUN-13:52 | 27.00 | 25.53 | 0.120870E+09 | 99.78 | 25-JUN-21:30 | 27.00 | 25.53 |
| July | 0.332954E+10 | 4491.46 | 03-JUL-14:02 | 24.60 | 23.22 | 0.129903E+09 | 101.41 | 19-JUL-20:10 | 23.13 | 22.36 |
| August | 0.327472E+10 | 4322.77 | 21-AUG-12:02 | 27.07 | 24.82 | 0.124501E+09 | 100.48 | 23-AUG-20:00 | 23.00 | 23.00 |
| September | 0.333627E+10 | 4253.53 | 14-SEP-16:52 | 25.00 | 25.00 | 0.124512E+09 | 101.53 | 15-SEP-18:30 | 24.00 | 24.00 |
| October | 0.331948E+10 | 4510.98 | 09-OCT-19:42 | 23.93 | 23.23 | 0.128207E+09 | 98.28 | 30-OCT-19:19 | 23.73 | 23.28 |
| November | 0.340361E+10 | 4675.83 | 25-NOV-19:52 | 23.00 | 21.65 | 0.126178E+09 | 110.81 | 25-NOV-09:50 | 23.00 | 21.65 |
| December | 0.354191E+10 | 5066.80 | 20-DEC-21:32 | 22.33 | 18.33 | 0.132555E+09 | 106.28 | 16-DEC-09:30 | 22.33 | 18.33 |
| Annual Sum or Average | 0.423148E+11 | 0.151044E+10 | ||||||||
| Minimum of Months | 0.327472E+10 | 4178.76 | 22.33 | 18.33 | 0.117234E+09 | 70.28 | 22.33 | 18.33 | ||
| Maximum of Months | 0.384913E+10 | 5524.24 | 29.00 | 26.74 | 0.132555E+09 | 112.88 | 29.03 | 26.72 |
Report: ZoneCoolingSummaryMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.291741E+10 | 4951.07 | 23-JAN-22:52 | 22.50 | 18.29 | 0.131145E+09 | 89.32 | 23-JAN-22:00 | 22.50 | 18.29 |
| February | 0.293454E+10 | 5212.16 | 21-FEB-10:52 | 30.00 | 21.82 | 0.118330E+09 | 82.95 | 15-FEB-06:00 | 30.00 | 21.82 |
| March | 0.358017E+10 | 4216.50 | 03-MAR-08:62 | 26.17 | 20.16 | 0.129053E+09 | 83.49 | 05-MAR-06:00 | 24.30 | 22.12 |
| April | 0.375063E+10 | 4217.69 | 14-APR-16:52 | 29.00 | 26.74 | 0.124655E+09 | 70.27 | 29-APR-05:00 | 27.00 | 25.53 |
| May | 0.395892E+10 | 4280.69 | 10-MAY-21:02 | 23.20 | 23.20 | 0.128983E+09 | 100.86 | 10-MAY-20:49 | 23.20 | 23.20 |
| June | 0.408479E+10 | 4383.58 | 25-JUN-19:52 | 23.00 | 23.00 | 0.125076E+09 | 102.19 | 25-JUN-21:30 | 23.05 | 22.93 |
| July | 0.358102E+10 | 4620.98 | 03-JUL-14:02 | 24.60 | 23.22 | 0.129299E+09 | 99.20 | 19-JUL-20:00 | 23.30 | 22.32 |
| August | 0.341730E+10 | 4354.01 | 21-AUG-12:02 | 27.07 | 24.82 | 0.129211E+09 | 99.98 | 23-AUG-20:49 | 23.00 | 22.88 |
| September | 0.326747E+10 | 4250.43 | 14-SEP-16:52 | 25.00 | 25.00 | 0.125207E+09 | 99.97 | 15-SEP-20:40 | 23.10 | 23.10 |
| October | 0.304237E+10 | 4434.85 | 09-OCT-20:02 | 24.00 | 23.26 | 0.129537E+09 | 92.43 | 09-OCT-20:10 | 24.00 | 23.26 |
| November | 0.287539E+10 | 4589.03 | 25-NOV-20:02 | 23.00 | 21.65 | 0.126467E+09 | 97.57 | 25-NOV-21:19 | 22.90 | 21.68 |
| December | 0.277827E+10 | 4908.87 | 20-DEC-22:02 | 21.83 | 18.17 | 0.131481E+09 | 94.59 | 20-DEC-21:49 | 21.83 | 18.17 |
| Annual Sum or Average | 0.401883E+11 | 0.152844E+10 | ||||||||
| Minimum of Months | 0.277827E+10 | 4216.50 | 21.83 | 18.17 | 0.118330E+09 | 70.27 | 21.83 | 18.17 | ||
| Maximum of Months | 0.408479E+10 | 5212.16 | 30.00 | 26.74 | 0.131481E+09 | 102.19 | 30.00 | 25.53 |
Report: ZoneCoolingSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.241658E+10 | 4614.84 | 23-JAN-22:52 | 22.50 | 18.29 | 0.130849E+09 | 88.94 | 23-JAN-22:00 | 22.50 | 18.29 |
| February | 0.237070E+10 | 4328.79 | 24-FEB-09:02 | 25.53 | 19.50 | 0.118037E+09 | 81.84 | 15-FEB-06:00 | 25.53 | 19.50 |
| March | 0.285130E+10 | 3919.83 | 03-MAR-08:62 | 26.17 | 20.16 | 0.129038E+09 | 82.19 | 05-MAR-06:00 | 24.30 | 22.12 |
| April | 0.297997E+10 | 3900.25 | 14-APR-16:52 | 29.00 | 26.74 | 0.124654E+09 | 70.27 | 20-APR-21:10 | 27.87 | 25.61 |
| May | 0.323633E+10 | 3961.66 | 10-MAY-21:02 | 23.20 | 23.20 | 0.128975E+09 | 99.23 | 10-MAY-20:49 | 23.20 | 23.20 |
| June | 0.334578E+10 | 4093.15 | 25-JUN-19:52 | 23.00 | 23.00 | 0.125059E+09 | 101.95 | 25-JUN-21:30 | 23.05 | 22.93 |
| July | 0.299398E+10 | 4303.57 | 19-JUL-19:52 | 23.10 | 22.37 | 0.129277E+09 | 98.65 | 19-JUL-20:00 | 23.30 | 22.32 |
| August | 0.280973E+10 | 3912.44 | 21-AUG-12:02 | 27.07 | 24.82 | 0.129205E+09 | 97.94 | 23-AUG-20:49 | 23.00 | 22.88 |
| September | 0.267038E+10 | 3935.49 | 14-SEP-16:52 | 25.00 | 25.00 | 0.125197E+09 | 100.11 | 15-SEP-20:40 | 23.10 | 23.10 |
| October | 0.253887E+10 | 4115.44 | 09-OCT-20:02 | 24.00 | 23.26 | 0.129536E+09 | 92.44 | 30-OCT-20:40 | 24.00 | 23.88 |
| November | 0.240048E+10 | 4257.92 | 25-NOV-20:02 | 23.00 | 21.65 | 0.126367E+09 | 97.28 | 25-NOV-21:19 | 22.90 | 21.68 |
| December | 0.232709E+10 | 4596.22 | 20-DEC-22:02 | 21.83 | 18.17 | 0.131220E+09 | 94.68 | 20-DEC-21:49 | 21.83 | 18.17 |
| Annual Sum or Average | 0.329412E+11 | 0.152741E+10 | ||||||||
| Minimum of Months | 0.232709E+10 | 3900.25 | 21.83 | 18.17 | 0.118037E+09 | 70.27 | 21.83 | 18.17 | ||
| Maximum of Months | 0.334578E+10 | 4614.84 | 29.00 | 26.74 | 0.131220E+09 | 101.95 | 27.87 | 25.61 |
Report: ZoneCoolingSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.241857E+10 | 4601.37 | 23-JAN-22:52 | 22.50 | 18.29 | 0.130859E+09 | 88.95 | 23-JAN-22:00 | 22.50 | 18.29 |
| February | 0.237268E+10 | 4317.51 | 24-FEB-09:02 | 25.53 | 19.50 | 0.118043E+09 | 81.85 | 15-FEB-06:00 | 25.53 | 19.50 |
| March | 0.285094E+10 | 3908.04 | 03-MAR-08:62 | 26.17 | 20.16 | 0.129038E+09 | 82.19 | 05-MAR-06:00 | 24.30 | 22.12 |
| April | 0.298058E+10 | 3887.04 | 14-APR-16:52 | 29.00 | 26.74 | 0.124654E+09 | 70.27 | 29-APR-05:00 | 27.00 | 25.53 |
| May | 0.323753E+10 | 3947.66 | 10-MAY-21:02 | 23.20 | 23.20 | 0.128974E+09 | 99.15 | 10-MAY-20:49 | 23.20 | 23.20 |
| June | 0.334735E+10 | 4077.05 | 25-JUN-19:52 | 23.00 | 23.00 | 0.125058E+09 | 101.80 | 25-JUN-21:30 | 23.05 | 22.93 |
| July | 0.299501E+10 | 4286.48 | 19-JUL-19:52 | 23.10 | 22.37 | 0.129277E+09 | 98.48 | 19-JUL-20:00 | 23.30 | 22.32 |
| August | 0.281127E+10 | 3903.61 | 21-AUG-12:02 | 27.07 | 24.82 | 0.129205E+09 | 97.84 | 23-AUG-20:49 | 23.00 | 22.88 |
| September | 0.267190E+10 | 3924.37 | 14-SEP-16:52 | 25.00 | 25.00 | 0.125197E+09 | 100.08 | 15-SEP-20:40 | 23.10 | 23.10 |
| October | 0.253949E+10 | 4101.99 | 09-OCT-20:02 | 24.00 | 23.26 | 0.129536E+09 | 92.44 | 30-OCT-20:40 | 24.00 | 23.88 |
| November | 0.240152E+10 | 4245.22 | 25-NOV-20:02 | 23.00 | 21.65 | 0.126369E+09 | 97.30 | 25-NOV-21:19 | 22.90 | 21.68 |
| December | 0.232880E+10 | 4581.29 | 20-DEC-22:02 | 21.83 | 18.17 | 0.131227E+09 | 94.61 | 20-DEC-21:49 | 21.83 | 18.17 |
| Annual Sum or Average | 0.329556E+11 | 0.152744E+10 | ||||||||
| Minimum of Months | 0.232880E+10 | 3887.04 | 21.83 | 18.17 | 0.118043E+09 | 70.27 | 21.83 | 18.17 | ||
| Maximum of Months | 0.334735E+10 | 4601.37 | 29.00 | 26.74 | 0.131227E+09 | 101.80 | 27.00 | 25.53 |
Report: ZoneCoolingSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.318740E+10 | 4618.63 | 23-JAN-22:52 | 22.50 | 18.29 | 0.132045E+09 | 103.02 | 15-JAN-10:09 | 22.50 | 18.29 |
| February | 0.294106E+10 | 4737.01 | 21-FEB-10:42 | 28.38 | 21.67 | 0.117000E+09 | 93.89 | 25-FEB-07:00 | 27.00 | 20.22 |
| March | 0.312311E+10 | 3909.72 | 03-MAR-08:62 | 26.17 | 20.16 | 0.124247E+09 | 92.31 | 03-MAR-07:00 | 26.17 | 20.16 |
| April | 0.293620E+10 | 3896.27 | 14-APR-16:52 | 29.00 | 26.74 | 0.123963E+09 | 70.28 | 14-APR-17:19 | 29.03 | 26.72 |
| May | 0.298736E+10 | 3885.11 | 10-MAY-21:02 | 23.20 | 23.20 | 0.125935E+09 | 98.11 | 10-MAY-20:49 | 23.20 | 23.20 |
| June | 0.290955E+10 | 3955.73 | 24-JUN-19:52 | 24.00 | 24.00 | 0.120850E+09 | 99.28 | 25-JUN-21:30 | 23.05 | 22.93 |
| July | 0.273990E+10 | 4023.73 | 19-JUL-20:22 | 23.20 | 22.35 | 0.129875E+09 | 99.77 | 19-JUL-20:10 | 23.20 | 22.35 |
| August | 0.266606E+10 | 3878.25 | 21-AUG-12:02 | 27.07 | 24.82 | 0.124500E+09 | 98.46 | 23-AUG-20:00 | 23.00 | 23.00 |
| September | 0.273999E+10 | 3940.17 | 14-SEP-16:52 | 25.00 | 25.00 | 0.124509E+09 | 100.83 | 15-SEP-18:30 | 24.00 | 24.00 |
| October | 0.281920E+10 | 4181.76 | 09-OCT-19:42 | 23.93 | 23.23 | 0.128210E+09 | 98.93 | 30-OCT-19:19 | 23.73 | 23.28 |
| November | 0.293434E+10 | 4325.36 | 25-NOV-19:52 | 23.00 | 21.65 | 0.126075E+09 | 102.13 | 25-NOV-09:50 | 23.00 | 21.65 |
| December | 0.309394E+10 | 4746.16 | 20-DEC-21:32 | 22.33 | 18.33 | 0.132338E+09 | 98.96 | 16-DEC-09:30 | 22.33 | 18.33 |
| Annual Sum or Average | 0.350781E+11 | 0.150955E+10 | ||||||||
| Minimum of Months | 0.266606E+10 | 3878.25 | 22.33 | 18.29 | 0.117000E+09 | 70.28 | 22.33 | 18.29 | ||
| Maximum of Months | 0.318740E+10 | 4746.16 | 29.00 | 26.74 | 0.132338E+09 | 103.02 | 29.03 | 26.72 |
Report: ZoneCoolingSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.318897E+10 | 4609.25 | 23-JAN-22:52 | 22.50 | 18.29 | 0.132052E+09 | 103.33 | 15-JAN-10:09 | 22.50 | 18.29 |
| February | 0.294277E+10 | 4738.61 | 21-FEB-10:42 | 28.38 | 21.67 | 0.117003E+09 | 94.02 | 25-FEB-07:00 | 27.00 | 20.22 |
| March | 0.312277E+10 | 3902.90 | 03-MAR-08:62 | 26.17 | 20.16 | 0.124248E+09 | 92.40 | 03-MAR-07:00 | 26.17 | 20.16 |
| April | 0.293681E+10 | 3885.69 | 14-APR-16:52 | 29.00 | 26.74 | 0.123963E+09 | 70.28 | 14-APR-17:19 | 29.03 | 26.72 |
| May | 0.298859E+10 | 3874.31 | 10-MAY-21:02 | 23.20 | 23.20 | 0.125934E+09 | 98.03 | 10-MAY-20:49 | 23.20 | 23.20 |
| June | 0.291113E+10 | 3946.55 | 24-JUN-19:52 | 24.00 | 24.00 | 0.120850E+09 | 99.14 | 25-JUN-21:30 | 23.05 | 22.93 |
| July | 0.274094E+10 | 4010.16 | 19-JUL-20:22 | 23.20 | 22.35 | 0.129874E+09 | 99.54 | 19-JUL-20:10 | 23.20 | 22.35 |
| August | 0.266760E+10 | 3873.13 | 21-AUG-12:02 | 27.07 | 24.82 | 0.124500E+09 | 98.36 | 23-AUG-20:00 | 23.00 | 23.00 |
| September | 0.274149E+10 | 3932.43 | 14-SEP-16:52 | 25.00 | 25.00 | 0.124508E+09 | 100.75 | 15-SEP-18:30 | 24.00 | 24.00 |
| October | 0.281983E+10 | 4171.65 | 09-OCT-19:42 | 23.93 | 23.23 | 0.128210E+09 | 98.95 | 30-OCT-19:19 | 23.73 | 23.28 |
| November | 0.293531E+10 | 4316.18 | 25-NOV-19:52 | 23.00 | 21.65 | 0.126078E+09 | 102.48 | 25-NOV-09:50 | 23.00 | 21.65 |
| December | 0.309540E+10 | 4735.74 | 20-DEC-21:32 | 22.33 | 18.33 | 0.132344E+09 | 99.22 | 16-DEC-09:30 | 22.33 | 18.33 |
| Annual Sum or Average | 0.350916E+11 | 0.150957E+10 | ||||||||
| Minimum of Months | 0.266760E+10 | 3873.13 | 22.33 | 18.29 | 0.117003E+09 | 70.28 | 22.33 | 18.29 | ||
| Maximum of Months | 0.318897E+10 | 4738.61 | 29.00 | 26.74 | 0.132344E+09 | 103.33 | 29.03 | 26.72 |
Report: ZoneCoolingSummaryMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 | 23.60 | 0.287961E+09 | 166.52 | 31-JAN-21:10 | 26.73 | 22.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 | 22.46 | 0.262607E+09 | 167.39 | 26-FEB-21:10 | 28.33 | 21.91 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 | 22.97 | 0.293227E+09 | 171.53 | 20-MAR-20:10 | 28.00 | 23.05 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 | 25.10 | 0.287317E+09 | 173.19 | 30-APR-20:10 | 29.53 | 26.24 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 | 26.40 | 0.297049E+09 | 177.62 | 06-MAY-20:10 | 30.83 | 25.83 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 | 23.91 | 0.289590E+09 | 176.89 | 12-JUN-20:10 | 29.97 | 26.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 | 24.33 | 0.292413E+09 | 173.99 | 15-JUL-20:10 | 28.92 | 25.01 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 | 24.75 | 0.290360E+09 | 171.75 | 01-AUG-20:10 | 29.00 | 27.47 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 | 25.66 | 0.282472E+09 | 171.04 | 02-SEP-20:10 | 27.83 | 26.34 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 | 25.35 | 0.288363E+09 | 168.29 | 04-OCT-20:10 | 27.92 | 25.10 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 | 24.37 | 0.278570E+09 | 168.05 | 25-NOV-21:49 | 22.75 | 21.72 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 | 23.43 | 0.285220E+09 | 165.80 | 08-DEC-21:10 | 28.02 | 24.22 |
| Annual Sum or Average | 0.00 | 0.343515E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 23.80 | 22.46 | 0.262607E+09 | 165.80 | 22.75 | 21.72 | ||
| Maximum of Months | 0.00 | 0.00 | 28.62 | 26.40 | 0.297049E+09 | 177.62 | 30.83 | 27.47 |
Report: ZoneCoolingSummaryMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 | 23.60 | 0.343470E+09 | 194.28 | 03-JAN-18:10 | 30.17 | 24.16 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 | 22.46 | 0.317156E+09 | 207.74 | 06-FEB-18:10 | 31.22 | 24.53 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 | 22.97 | 0.354444E+09 | 213.38 | 19-MAR-17:10 | 31.67 | 23.98 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 | 25.10 | 0.348960E+09 | 218.96 | 11-APR-17:10 | 32.67 | 26.58 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 | 26.40 | 0.361363E+09 | 230.47 | 29-MAY-17:10 | 33.83 | 26.60 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 | 23.91 | 0.351301E+09 | 231.23 | 12-JUN-17:10 | 33.67 | 27.22 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 | 24.33 | 0.349242E+09 | 218.69 | 15-JUL-17:10 | 32.83 | 25.61 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 | 24.75 | 0.348097E+09 | 210.98 | 27-AUG-17:10 | 31.67 | 26.84 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 | 25.66 | 0.337704E+09 | 213.38 | 02-SEP-17:10 | 32.08 | 26.93 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 | 25.35 | 0.342198E+09 | 194.63 | 04-OCT-17:10 | 30.33 | 25.99 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 | 24.37 | 0.331804E+09 | 196.16 | 19-NOV-21:10 | 27.93 | 25.72 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 | 23.43 | 0.339490E+09 | 193.82 | 08-DEC-21:10 | 28.02 | 24.22 |
| Annual Sum or Average | 0.00 | 0.412523E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 23.80 | 22.46 | 0.317156E+09 | 193.82 | 27.93 | 23.98 | ||
| Maximum of Months | 0.00 | 0.00 | 28.62 | 26.40 | 0.361363E+09 | 231.23 | 33.83 | 27.22 |
Report: ZoneCoolingSummaryMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 | 23.60 | 0.286108E+09 | 160.76 | 31-JAN-21:10 | 26.73 | 22.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 | 22.46 | 0.260108E+09 | 161.07 | 24-FEB-21:10 | 27.38 | 21.32 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 | 22.97 | 0.287123E+09 | 161.75 | 20-MAR-20:10 | 28.00 | 23.05 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 | 25.10 | 0.278748E+09 | 161.90 | 30-APR-20:10 | 29.53 | 26.24 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 | 26.40 | 0.287850E+09 | 164.75 | 06-MAY-20:10 | 30.83 | 25.83 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 | 23.91 | 0.280328E+09 | 164.35 | 12-JUN-20:10 | 29.97 | 26.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 | 24.33 | 0.285379E+09 | 161.95 | 19-JUL-21:49 | 23.38 | 22.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 | 24.75 | 0.284091E+09 | 160.57 | 14-AUG-20:10 | 29.00 | 28.18 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 | 25.66 | 0.275461E+09 | 160.29 | 02-SEP-20:10 | 27.83 | 26.34 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 | 25.35 | 0.283076E+09 | 160.62 | 09-OCT-20:19 | 24.00 | 23.26 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 | 24.37 | 0.275387E+09 | 162.31 | 25-NOV-23:10 | 23.00 | 22.27 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 | 23.43 | 0.284659E+09 | 160.36 | 26-DEC-22:00 | 22.00 | 19.30 |
| Annual Sum or Average | 0.00 | 0.336832E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 23.80 | 22.46 | 0.260108E+09 | 160.29 | 22.00 | 19.30 | ||
| Maximum of Months | 0.00 | 0.00 | 28.62 | 26.40 | 0.287850E+09 | 164.75 | 30.83 | 28.18 |
Report: ZoneHeatingSummaryMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 256139.67 | 45.22 | 31-JAN-10:34 | 27.67 |
| February | 356497.46 | 58.78 | 21-FEB-10:43 | 28.38 |
| March | 86882.20 | 27.65 | 15-MAR-07:27 | 24.20 |
| April | 34240.37 | 33.56 | 14-APR-16:35 | 26.97 |
| May | 25819.54 | 48.08 | 21-MAY-14:07 | 26.17 |
| June | 85772.26 | 51.04 | 21-JUN-07:17 | 26.27 |
| July | 135654.27 | 46.92 | 29-JUL-06:47 | 26.08 |
| August | 86080.87 | 45.90 | 20-AUG-07:47 | 25.67 |
| September | 42457.33 | 26.01 | 18-SEP-08:37 | 24.00 |
| October | 91838.43 | 39.46 | 31-OCT-07:07 | 25.25 |
| November | 197148.58 | 44.77 | 19-NOV-08:17 | 25.90 |
| December | 364061.49 | 55.68 | 16-DEC-09:47 | 26.83 |
| Annual Sum or Average | 1762592.47 | |||
| Minimum of Months | 25819.54 | 26.01 | 24.00 | |
| Maximum of Months | 364061.49 | 58.78 | 28.38 |
Report: ZoneHeatingSummaryMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 667328.07 | 78.59 | 15-JAN-11:17 | 28.87 |
| February | 569462.94 | 70.69 | 21-FEB-10:54 | 30.00 |
| March | 112542.83 | 27.81 | 15-MAR-07:27 | 24.20 |
| April | 33078.14 | 32.97 | 14-APR-16:35 | 26.97 |
| May | 22983.21 | 23.89 | 21-MAY-14:07 | 26.17 |
| June | 79275.67 | 51.00 | 21-JUN-07:17 | 26.27 |
| July | 95227.56 | 38.96 | 13-JUL-06:57 | 25.30 |
| August | 79309.56 | 45.59 | 20-AUG-07:47 | 25.67 |
| September | 42230.39 | 26.33 | 18-SEP-08:37 | 24.00 |
| October | 114908.40 | 39.47 | 31-OCT-07:07 | 25.25 |
| November | 292623.08 | 44.66 | 19-NOV-08:17 | 25.90 |
| December | 557366.53 | 56.45 | 16-DEC-09:47 | 26.83 |
| Annual Sum or Average | 2666336.39 | |||
| Minimum of Months | 22983.21 | 23.89 | 24.00 | |
| Maximum of Months | 667328.07 | 78.59 | 30.00 |
Report: ZoneHeatingSummaryMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.336909E+09 | 571.54 | 10-JAN-17:12 | 30.13 |
| February | 0.356009E+09 | 635.72 | 24-FEB-17:13 | 32.33 |
| March | 0.453146E+09 | 679.81 | 29-MAR-16:13 | 33.27 |
| April | 0.500639E+09 | 710.95 | 11-APR-16:13 | 34.07 |
| May | 0.446715E+09 | 736.75 | 05-MAY-16:13 | 34.73 |
| June | 0.444264E+09 | 723.43 | 13-JUN-16:13 | 34.67 |
| July | 0.461422E+09 | 694.46 | 20-JUL-16:12 | 32.63 |
| August | 0.483651E+09 | 649.28 | 01-AUG-16:13 | 32.47 |
| September | 0.450281E+09 | 650.97 | 13-SEP-16:13 | 32.33 |
| October | 0.441659E+09 | 601.56 | 04-OCT-16:13 | 31.17 |
| November | 0.379184E+09 | 568.55 | 03-NOV-16:13 | 30.47 |
| December | 0.342304E+09 | 559.70 | 13-DEC-17:13 | 30.33 |
| Annual Sum or Average | 0.509618E+10 | |||
| Minimum of Months | 0.336909E+09 | 559.70 | 30.13 | |
| Maximum of Months | 0.500639E+09 | 736.75 | 34.73 |
Report: ZoneHeatingSummaryMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 701072.53 | 79.19 | 15-JAN-11:17 | 28.87 |
| February | 473522.58 | 78.02 | 21-FEB-10:54 | 30.00 |
| March | 85628.57 | 42.76 | 02-MAR-07:47 | 25.67 |
| April | 47675.43 | 80.60 | 14-APR-16:57 | 29.00 |
| May | 28055.78 | 49.12 | 21-MAY-14:07 | 26.17 |
| June | 74683.26 | 52.38 | 21-JUN-07:17 | 26.27 |
| July | 91423.52 | 48.15 | 29-JUL-06:47 | 26.08 |
| August | 83355.85 | 59.01 | 21-AUG-12:07 | 27.07 |
| September | 49119.28 | 34.51 | 14-SEP-16:57 | 25.00 |
| October | 106812.55 | 40.68 | 31-OCT-07:07 | 25.25 |
| November | 220659.31 | 46.16 | 19-NOV-08:17 | 25.90 |
| December | 515479.58 | 56.81 | 16-DEC-09:47 | 26.83 |
| Annual Sum or Average | 2477488.23 | |||
| Minimum of Months | 28055.78 | 34.51 | 25.00 | |
| Maximum of Months | 701072.53 | 80.60 | 30.00 |
Report: ZoneHeatingSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 1021775.57 | 92.27 | 31-JAN-10:57 | 30.00 |
| February | 799032.95 | 98.46 | 21-FEB-11:17 | 30.67 |
| March | 184130.98 | 50.00 | 03-MAR-08:20 | 26.33 |
| April | 65809.22 | 82.91 | 14-APR-16:57 | 29.00 |
| May | 42269.72 | 51.63 | 21-MAY-14:07 | 26.17 |
| June | 111619.56 | 58.42 | 30-JUN-13:57 | 27.00 |
| July | 130220.78 | 50.78 | 29-JUL-06:47 | 26.08 |
| August | 108211.29 | 61.80 | 21-AUG-12:07 | 27.07 |
| September | 69266.72 | 37.26 | 14-SEP-16:57 | 25.00 |
| October | 183244.66 | 42.71 | 31-OCT-07:07 | 25.25 |
| November | 412684.14 | 48.62 | 19-NOV-08:17 | 25.90 |
| December | 1163701.71 | 60.07 | 16-DEC-09:47 | 26.83 |
| Annual Sum or Average | 4291967.30 | |||
| Minimum of Months | 42269.72 | 37.26 | 25.00 | |
| Maximum of Months | 1163701.71 | 98.46 | 30.67 |
Report: ZoneHeatingSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 1007249.60 | 92.32 | 31-JAN-10:57 | 30.00 |
| February | 783599.08 | 98.53 | 21-FEB-11:17 | 30.67 |
| March | 183009.29 | 49.96 | 03-MAR-08:20 | 26.33 |
| April | 66394.95 | 82.93 | 14-APR-16:57 | 29.00 |
| May | 42281.79 | 51.66 | 21-MAY-14:07 | 26.17 |
| June | 111473.19 | 58.47 | 30-JUN-13:57 | 27.00 |
| July | 130165.92 | 50.81 | 29-JUL-06:47 | 26.08 |
| August | 107848.29 | 61.83 | 21-AUG-12:07 | 27.07 |
| September | 68245.64 | 37.29 | 14-SEP-16:57 | 25.00 |
| October | 181712.10 | 42.67 | 31-OCT-07:07 | 25.25 |
| November | 409284.63 | 48.65 | 19-NOV-08:17 | 25.90 |
| December | 1125551.93 | 60.12 | 16-DEC-09:47 | 26.83 |
| Annual Sum or Average | 4216816.41 | |||
| Minimum of Months | 42281.79 | 37.29 | 25.00 | |
| Maximum of Months | 1125551.93 | 98.53 | 30.67 |
Report: ZoneHeatingSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 373592.50 | 91.91 | 31-JAN-10:57 | 30.00 |
| February | 460116.24 | 94.25 | 21-FEB-11:07 | 30.33 |
| March | 127759.53 | 49.86 | 03-MAR-08:07 | 26.17 |
| April | 75491.65 | 82.21 | 14-APR-16:57 | 29.00 |
| May | 43972.64 | 51.88 | 21-MAY-14:07 | 26.17 |
| June | 118737.58 | 53.58 | 21-JUN-07:17 | 26.27 |
| July | 202097.95 | 51.96 | 29-JUL-07:00 | 26.50 |
| August | 107742.59 | 61.63 | 21-AUG-12:07 | 27.07 |
| September | 64465.24 | 36.82 | 14-SEP-16:57 | 25.00 |
| October | 107848.44 | 42.69 | 31-OCT-07:07 | 25.25 |
| November | 233580.55 | 48.82 | 19-NOV-08:17 | 25.90 |
| December | 430239.86 | 58.87 | 16-DEC-09:47 | 26.83 |
| Annual Sum or Average | 2345644.78 | |||
| Minimum of Months | 43972.64 | 36.82 | 25.00 | |
| Maximum of Months | 460116.24 | 94.25 | 30.33 |
Report: ZoneHeatingSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 307039.14 | 91.54 | 31-JAN-10:57 | 30.00 |
| February | 384956.75 | 91.47 | 23-FEB-10:57 | 30.00 |
| March | 83347.66 | 49.51 | 03-MAR-08:07 | 26.17 |
| April | 64716.79 | 82.42 | 14-APR-16:57 | 29.00 |
| May | 30647.14 | 51.56 | 21-MAY-14:07 | 26.17 |
| June | 110154.30 | 54.16 | 21-JUN-07:17 | 26.27 |
| July | 136510.91 | 50.59 | 29-JUL-06:47 | 26.08 |
| August | 100452.96 | 61.22 | 21-AUG-12:07 | 27.07 |
| September | 52911.24 | 36.64 | 14-SEP-16:57 | 25.00 |
| October | 85527.15 | 42.58 | 31-OCT-07:07 | 25.25 |
| November | 187494.57 | 48.08 | 19-NOV-08:17 | 25.90 |
| December | 376074.94 | 58.52 | 16-DEC-09:47 | 26.83 |
| Annual Sum or Average | 1919833.55 | |||
| Minimum of Months | 30647.14 | 36.64 | 25.00 | |
| Maximum of Months | 384956.75 | 91.54 | 30.00 |
Report: ZoneHeatingSummaryMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 393955.04 | 58.53 | 24-JAN-10:45 | 26.57 |
| February | 636890.71 | 99.56 | 21-FEB-11:05 | 30.33 |
| March | 197266.84 | 54.66 | 03-MAR-08:05 | 26.17 |
| April | 57596.99 | 45.89 | 14-APR-16:43 | 27.98 |
| May | 37872.64 | 21.75 | 10-MAY-21:05 | 23.20 |
| June | 179059.01 | 66.50 | 30-JUN-13:55 | 27.00 |
| July | 222873.80 | 54.28 | 29-JUL-06:45 | 26.08 |
| August | 140044.44 | 41.52 | 20-AUG-13:17 | 25.33 |
| September | 72676.29 | 40.98 | 14-SEP-16:55 | 25.00 |
| October | 185439.73 | 40.53 | 09-OCT-06:35 | 24.80 |
| November | 351667.56 | 44.09 | 17-NOV-07:25 | 25.15 |
| December | 568089.36 | 53.07 | 24-DEC-09:47 | 26.50 |
| Annual Sum or Average | 3043432.40 | |||
| Minimum of Months | 37872.64 | 21.75 | 23.20 | |
| Maximum of Months | 636890.71 | 99.56 | 30.33 |
Report: ZoneHeatingSummaryMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 1269249.66 | 91.62 | 31-JAN-10:55 | 30.00 |
| February | 1077803.05 | 104.76 | 21-FEB-11:15 | 30.67 |
| March | 217407.12 | 55.87 | 03-MAR-08:05 | 26.17 |
| April | 54636.17 | 45.23 | 14-APR-16:43 | 27.98 |
| May | 38171.78 | 22.87 | 10-MAY-21:05 | 23.20 |
| June | 152180.30 | 65.33 | 30-JUN-13:55 | 27.00 |
| July | 205848.99 | 53.95 | 29-JUL-06:45 | 26.08 |
| August | 135030.57 | 40.80 | 20-AUG-13:17 | 25.33 |
| September | 77669.91 | 23.96 | 15-SEP-18:47 | 24.00 |
| October | 217964.23 | 41.44 | 09-OCT-06:35 | 24.80 |
| November | 531183.42 | 51.18 | 22-NOV-07:45 | 25.67 |
| December | 1359118.08 | 59.06 | 27-DEC-09:05 | 26.40 |
| Annual Sum or Average | 5336263.26 | |||
| Minimum of Months | 38171.78 | 22.87 | 23.20 | |
| Maximum of Months | 1359118.08 | 104.76 | 30.67 |
Report: ZoneHeatingSummaryMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 322492.61 | 47.39 | 31-JAN-10:34 | 27.67 |
| February | 407713.89 | 58.12 | 21-FEB-10:43 | 28.38 |
| March | 129438.95 | 15.48 | 02-MAR-07:40 | 25.33 |
| April | 68255.20 | 47.07 | 14-APR-16:43 | 27.98 |
| May | 38736.44 | 23.37 | 31-MAY-21:47 | 23.98 |
| June | 161702.30 | 65.72 | 30-JUN-13:55 | 27.00 |
| July | 187461.27 | 38.43 | 19-JUL-06:55 | 24.70 |
| August | 135232.89 | 43.25 | 20-AUG-07:47 | 25.67 |
| September | 70824.91 | 25.37 | 18-SEP-08:37 | 24.00 |
| October | 175496.55 | 37.89 | 31-OCT-07:07 | 25.25 |
| November | 211370.41 | 34.72 | 02-NOV-07:37 | 24.87 |
| December | 429022.35 | 53.85 | 14-DEC-09:47 | 26.67 |
| Annual Sum or Average | 2337747.77 | |||
| Minimum of Months | 38736.44 | 15.48 | 23.98 | |
| Maximum of Months | 429022.35 | 65.72 | 28.38 |
Report: ZoneHeatingSummaryMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 715685.01 | 78.97 | 15-JAN-11:17 | 28.87 |
| February | 640368.72 | 73.90 | 21-FEB-10:54 | 30.00 |
| March | 154453.65 | 47.84 | 02-MAR-07:45 | 25.67 |
| April | 66530.00 | 46.41 | 14-APR-16:43 | 27.98 |
| May | 35248.21 | 17.69 | 21-MAY-13:40 | 25.13 |
| June | 109318.46 | 64.52 | 30-JUN-13:55 | 27.00 |
| July | 177878.33 | 38.23 | 13-JUL-06:57 | 25.30 |
| August | 132815.95 | 42.61 | 20-AUG-07:47 | 25.67 |
| September | 73954.71 | 25.48 | 18-SEP-08:37 | 24.00 |
| October | 201047.47 | 38.39 | 09-OCT-06:35 | 24.80 |
| November | 365777.09 | 42.43 | 17-NOV-07:25 | 25.15 |
| December | 764489.97 | 55.72 | 16-DEC-09:47 | 26.83 |
| Annual Sum or Average | 3437567.56 | |||
| Minimum of Months | 35248.21 | 17.69 | 24.00 | |
| Maximum of Months | 764489.97 | 78.97 | 30.00 |
Report: ZoneHeatingSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 1425796.77 | 81.18 | 15-JAN-11:17 | 28.87 |
| February | 1187024.03 | 92.61 | 23-FEB-11:07 | 30.17 |
| March | 213689.71 | 48.44 | 02-MAR-07:45 | 25.67 |
| April | 80755.42 | 48.37 | 14-APR-16:43 | 27.98 |
| May | 58942.44 | 25.50 | 31-MAY-21:47 | 23.98 |
| June | 180620.28 | 63.22 | 30-JUN-13:55 | 27.00 |
| July | 207849.70 | 37.16 | 19-JUL-06:55 | 24.70 |
| August | 173975.02 | 59.51 | 21-AUG-12:07 | 27.07 |
| September | 96077.40 | 25.87 | 18-SEP-08:37 | 24.00 |
| October | 230266.21 | 38.14 | 09-OCT-06:35 | 24.80 |
| November | 530066.63 | 48.51 | 22-NOV-07:45 | 25.67 |
| December | 1371530.08 | 56.03 | 16-DEC-09:47 | 26.83 |
| Annual Sum or Average | 5756593.69 | |||
| Minimum of Months | 58942.44 | 25.50 | 23.98 | |
| Maximum of Months | 1425796.77 | 92.61 | 30.17 |
Report: ZoneHeatingSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 1416859.23 | 81.24 | 15-JAN-11:17 | 28.87 |
| February | 1172738.69 | 92.68 | 23-FEB-11:07 | 30.17 |
| March | 213476.91 | 48.40 | 02-MAR-07:45 | 25.67 |
| April | 80802.39 | 48.39 | 14-APR-16:43 | 27.98 |
| May | 58961.26 | 25.53 | 31-MAY-21:47 | 23.98 |
| June | 180404.07 | 63.18 | 30-JUN-13:55 | 27.00 |
| July | 209959.79 | 37.99 | 13-JUL-06:57 | 25.30 |
| August | 173656.35 | 59.54 | 21-AUG-12:07 | 27.07 |
| September | 95870.04 | 25.93 | 18-SEP-08:37 | 24.00 |
| October | 229989.26 | 38.14 | 31-OCT-07:07 | 25.25 |
| November | 528761.31 | 48.44 | 22-NOV-07:45 | 25.67 |
| December | 1369537.51 | 56.19 | 16-DEC-09:47 | 26.83 |
| Annual Sum or Average | 5731016.83 | |||
| Minimum of Months | 58961.26 | 25.53 | 23.98 | |
| Maximum of Months | 1416859.23 | 92.68 | 30.17 |
Report: ZoneHeatingSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 482089.78 | 73.62 | 22-JAN-11:17 | 28.33 |
| February | 704673.41 | 69.42 | 23-FEB-10:57 | 30.00 |
| March | 194525.70 | 47.65 | 02-MAR-07:45 | 25.67 |
| April | 82704.50 | 49.06 | 14-APR-16:43 | 27.98 |
| May | 60788.26 | 24.79 | 31-MAY-21:47 | 23.98 |
| June | 207205.80 | 64.50 | 30-JUN-13:55 | 27.00 |
| July | 241461.22 | 38.32 | 19-JUL-06:55 | 24.70 |
| August | 189915.08 | 59.32 | 21-AUG-12:07 | 27.07 |
| September | 94284.54 | 26.70 | 15-SEP-18:47 | 24.00 |
| October | 191763.43 | 39.06 | 31-OCT-07:07 | 25.25 |
| November | 385401.63 | 46.30 | 19-NOV-08:17 | 25.90 |
| December | 681966.40 | 58.14 | 16-DEC-09:47 | 26.83 |
| Annual Sum or Average | 3516779.75 | |||
| Minimum of Months | 60788.26 | 24.79 | 23.98 | |
| Maximum of Months | 704673.41 | 73.62 | 30.00 |
Report: ZoneHeatingSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 477547.68 | 73.61 | 22-JAN-11:17 | 28.33 |
| February | 692649.28 | 68.99 | 23-FEB-10:57 | 30.00 |
| March | 194318.77 | 47.61 | 02-MAR-07:45 | 25.67 |
| April | 82755.99 | 49.08 | 14-APR-16:43 | 27.98 |
| May | 60807.23 | 24.79 | 31-MAY-21:47 | 23.98 |
| June | 206940.39 | 64.46 | 30-JUN-13:55 | 27.00 |
| July | 241162.20 | 38.28 | 19-JUL-06:55 | 24.70 |
| August | 189571.59 | 59.39 | 21-AUG-12:07 | 27.07 |
| September | 94078.49 | 26.67 | 15-SEP-18:47 | 24.00 |
| October | 191567.80 | 39.12 | 31-OCT-07:07 | 25.25 |
| November | 384500.90 | 46.33 | 19-NOV-08:17 | 25.90 |
| December | 681002.92 | 58.14 | 16-DEC-09:47 | 26.83 |
| Annual Sum or Average | 3496903.25 | |||
| Minimum of Months | 60807.23 | 24.79 | 23.98 | |
| Maximum of Months | 692649.28 | 73.61 | 30.00 |
Report: ZoneHeatingSummaryMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 406323.35 | 53.02 | 20-JAN-08:05 | 25.92 |
| February | 663394.64 | 60.56 | 25-FEB-08:15 | 26.33 |
| March | 215197.11 | 56.22 | 03-MAR-08:05 | 26.17 |
| April | 48020.11 | 89.11 | 14-APR-16:55 | 29.00 |
| May | 36066.34 | 56.81 | 21-MAY-14:05 | 26.17 |
| June | 167330.73 | 68.73 | 30-JUN-13:55 | 27.00 |
| July | 246354.83 | 55.09 | 29-JUL-06:45 | 26.08 |
| August | 130082.43 | 46.80 | 20-AUG-08:00 | 26.00 |
| September | 66478.13 | 45.65 | 14-SEP-16:55 | 25.00 |
| October | 180822.42 | 42.30 | 31-OCT-07:20 | 25.60 |
| November | 368231.54 | 50.42 | 22-NOV-07:45 | 25.67 |
| December | 535832.74 | 52.68 | 01-DEC-08:47 | 26.50 |
| Annual Sum or Average | 3064134.37 | |||
| Minimum of Months | 36066.34 | 42.30 | 25.00 | |
| Maximum of Months | 663394.64 | 89.11 | 29.00 |
Report: ZoneHeatingSummaryMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 1095366.05 | 96.69 | 31-JAN-10:55 | 30.00 |
| February | 1019064.94 | 74.88 | 21-FEB-10:54 | 30.00 |
| March | 240267.34 | 56.38 | 03-MAR-08:05 | 26.17 |
| April | 41079.40 | 87.83 | 14-APR-16:55 | 29.00 |
| May | 36350.28 | 57.35 | 21-MAY-14:05 | 26.17 |
| June | 119056.50 | 68.72 | 30-JUN-13:55 | 27.00 |
| July | 202701.88 | 55.00 | 29-JUL-06:45 | 26.08 |
| August | 128341.70 | 46.97 | 20-AUG-08:00 | 26.00 |
| September | 66012.06 | 45.18 | 14-SEP-16:55 | 25.00 |
| October | 193509.54 | 42.32 | 09-OCT-06:35 | 24.80 |
| November | 531401.75 | 52.14 | 22-NOV-07:45 | 25.67 |
| December | 1244750.97 | 60.44 | 28-DEC-08:45 | 26.50 |
| Annual Sum or Average | 4917902.40 | |||
| Minimum of Months | 36350.28 | 42.32 | 24.80 | |
| Maximum of Months | 1244750.97 | 96.69 | 30.00 |
Report: ZoneHeatingSummaryMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 285151.29 | 50.77 | 22-JAN-10:55 | 28.00 |
| February | 417098.56 | 59.20 | 21-FEB-10:45 | 28.38 |
| March | 131730.79 | 27.92 | 15-MAR-07:27 | 24.20 |
| April | 49511.41 | 44.66 | 14-APR-16:43 | 27.98 |
| May | 26115.00 | 23.37 | 31-MAY-21:47 | 23.98 |
| June | 119737.84 | 67.07 | 30-JUN-13:55 | 27.00 |
| July | 176752.16 | 39.33 | 22-JUL-08:07 | 25.25 |
| August | 127966.31 | 46.77 | 20-AUG-08:00 | 26.00 |
| September | 61419.60 | 43.06 | 14-SEP-16:55 | 25.00 |
| October | 138278.16 | 39.54 | 31-OCT-07:07 | 25.25 |
| November | 247541.68 | 45.38 | 19-NOV-08:17 | 25.90 |
| December | 388844.83 | 52.95 | 01-DEC-08:47 | 26.50 |
| Annual Sum or Average | 2170147.63 | |||
| Minimum of Months | 26115.00 | 23.37 | 23.98 | |
| Maximum of Months | 417098.56 | 67.07 | 28.38 |
Report: ZoneHeatingSummaryMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 583077.64 | 56.51 | 15-JAN-10:56 | 28.50 |
| February | 610383.87 | 69.87 | 21-FEB-10:56 | 30.00 |
| March | 148654.43 | 27.66 | 15-MAR-07:27 | 24.20 |
| April | 45405.28 | 44.00 | 14-APR-16:43 | 27.98 |
| May | 23757.29 | 16.00 | 21-MAY-13:25 | 24.70 |
| June | 98277.87 | 67.39 | 30-JUN-13:55 | 27.00 |
| July | 160628.96 | 39.04 | 13-JUL-06:57 | 25.30 |
| August | 127705.99 | 46.95 | 20-AUG-08:00 | 26.00 |
| September | 58168.51 | 42.84 | 14-SEP-16:55 | 25.00 |
| October | 169919.71 | 39.13 | 31-OCT-07:07 | 25.25 |
| November | 328824.99 | 45.05 | 19-NOV-08:17 | 25.90 |
| December | 624967.75 | 55.47 | 31-DEC-08:37 | 26.67 |
| Annual Sum or Average | 2979772.29 | |||
| Minimum of Months | 23757.29 | 16.00 | 24.20 | |
| Maximum of Months | 624967.75 | 69.87 | 30.00 |
Report: ZoneHeatingSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 1133284.33 | 79.25 | 08-JAN-10:47 | 28.63 |
| February | 1015032.74 | 71.34 | 21-FEB-10:54 | 30.00 |
| March | 235959.29 | 49.92 | 03-MAR-08:20 | 26.33 |
| April | 56986.64 | 45.14 | 14-APR-16:43 | 27.98 |
| May | 43172.90 | 48.51 | 21-MAY-14:07 | 26.17 |
| June | 114941.61 | 64.73 | 30-JUN-13:55 | 27.00 |
| July | 218110.40 | 40.03 | 22-JUL-08:07 | 25.25 |
| August | 137328.04 | 58.25 | 21-AUG-12:07 | 27.07 |
| September | 71584.47 | 28.42 | 18-SEP-08:37 | 24.00 |
| October | 211480.35 | 42.71 | 31-OCT-07:20 | 25.60 |
| November | 514219.32 | 49.05 | 22-NOV-07:45 | 25.67 |
| December | 1280890.03 | 57.72 | 16-DEC-09:47 | 26.83 |
| Annual Sum or Average | 5032990.14 | |||
| Minimum of Months | 43172.90 | 28.42 | 24.00 | |
| Maximum of Months | 1280890.03 | 79.25 | 30.00 |
Report: ZoneHeatingSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 1084579.63 | 79.23 | 08-JAN-10:47 | 28.63 |
| February | 991047.73 | 71.82 | 21-FEB-10:54 | 30.00 |
| March | 224894.37 | 49.77 | 03-MAR-08:20 | 26.33 |
| April | 57145.52 | 45.21 | 14-APR-16:43 | 27.98 |
| May | 43179.03 | 48.59 | 21-MAY-14:07 | 26.17 |
| June | 114659.96 | 64.64 | 30-JUN-13:55 | 27.00 |
| July | 216070.33 | 40.12 | 22-JUL-08:07 | 25.25 |
| August | 135143.50 | 58.31 | 21-AUG-12:07 | 27.07 |
| September | 71558.42 | 28.49 | 18-SEP-08:37 | 24.00 |
| October | 209916.03 | 42.70 | 31-OCT-07:20 | 25.60 |
| November | 507641.71 | 48.87 | 22-NOV-07:45 | 25.67 |
| December | 1223653.88 | 57.84 | 16-DEC-09:47 | 26.83 |
| Annual Sum or Average | 4879490.10 | |||
| Minimum of Months | 43179.03 | 28.49 | 24.00 | |
| Maximum of Months | 1223653.88 | 79.23 | 30.00 |
Report: ZoneHeatingSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 397948.71 | 47.92 | 12-JAN-07:57 | 26.00 |
| February | 625328.43 | 56.33 | 21-FEB-10:43 | 28.38 |
| March | 188319.19 | 48.60 | 02-MAR-07:45 | 25.67 |
| April | 60242.23 | 46.05 | 14-APR-16:43 | 27.98 |
| May | 43833.15 | 49.08 | 21-MAY-14:07 | 26.17 |
| June | 198788.27 | 65.63 | 30-JUN-13:55 | 27.00 |
| July | 243682.87 | 51.92 | 29-JUL-07:00 | 26.50 |
| August | 129073.91 | 58.58 | 21-AUG-12:07 | 27.07 |
| September | 67353.36 | 28.26 | 18-SEP-08:37 | 24.00 |
| October | 171160.30 | 42.27 | 31-OCT-07:20 | 25.60 |
| November | 317613.68 | 46.90 | 19-NOV-08:17 | 25.90 |
| December | 512101.24 | 56.72 | 16-DEC-09:47 | 26.83 |
| Annual Sum or Average | 2955445.35 | |||
| Minimum of Months | 43833.15 | 28.26 | 24.00 | |
| Maximum of Months | 625328.43 | 65.63 | 28.38 |
Report: ZoneHeatingSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 396565.57 | 48.00 | 12-JAN-07:57 | 26.00 |
| February | 618403.64 | 53.70 | 20-FEB-07:55 | 26.00 |
| March | 187820.93 | 48.50 | 02-MAR-07:45 | 25.67 |
| April | 64919.00 | 46.13 | 14-APR-16:43 | 27.98 |
| May | 43864.27 | 49.14 | 21-MAY-14:07 | 26.17 |
| June | 196135.24 | 65.57 | 30-JUN-13:55 | 27.00 |
| July | 243434.87 | 51.91 | 29-JUL-07:00 | 26.50 |
| August | 128793.68 | 58.61 | 21-AUG-12:07 | 27.07 |
| September | 67293.03 | 28.36 | 18-SEP-08:37 | 24.00 |
| October | 169678.27 | 42.22 | 31-OCT-07:20 | 25.60 |
| November | 317050.84 | 46.97 | 19-NOV-08:17 | 25.90 |
| December | 500601.98 | 56.32 | 16-DEC-09:47 | 26.83 |
| Annual Sum or Average | 2934561.32 | |||
| Minimum of Months | 43864.27 | 28.36 | 24.00 | |
| Maximum of Months | 618403.64 | 65.57 | 27.98 |
Report: ZoneHeatingSummaryMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 28.62 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 23.80 | |
| Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneElectricSummaryMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.468251E+09 | 447.62 | 03-JAN-08:09 | 0.621586E+09 | 544.92 | 03-JAN-08:09 |
| February | 0.433623E+09 | 447.62 | 01-FEB-08:09 | 0.574385E+09 | 544.92 | 01-FEB-08:09 |
| March | 0.502522E+09 | 447.62 | 01-MAR-08:09 | 0.663122E+09 | 544.92 | 01-MAR-08:09 |
| April | 0.460516E+09 | 447.62 | 03-APR-07:10 | 0.610467E+09 | 544.92 | 03-APR-07:10 |
| May | 0.491098E+09 | 447.62 | 01-MAY-07:10 | 0.649277E+09 | 544.92 | 01-MAY-07:10 |
| June | 0.483363E+09 | 447.62 | 01-JUN-07:10 | 0.638158E+09 | 544.92 | 01-JUN-07:10 |
| July | 0.468251E+09 | 447.62 | 03-JUL-07:10 | 0.621586E+09 | 544.92 | 03-JUL-07:10 |
| August | 0.502522E+09 | 447.62 | 01-AUG-07:10 | 0.663122E+09 | 544.92 | 01-AUG-07:10 |
| September | 0.460516E+09 | 447.62 | 01-SEP-07:10 | 0.610467E+09 | 544.92 | 01-SEP-07:10 |
| October | 0.479675E+09 | 447.62 | 02-OCT-07:10 | 0.635432E+09 | 544.92 | 02-OCT-07:10 |
| November | 0.460516E+09 | 447.62 | 01-NOV-07:10 | 0.610467E+09 | 544.92 | 01-NOV-07:10 |
| December | 0.468251E+09 | 447.62 | 01-DEC-08:09 | 0.621586E+09 | 544.92 | 01-DEC-08:09 |
| Annual Sum or Average | 0.567911E+10 | 0.751966E+10 | ||||
| Minimum of Months | 0.433623E+09 | 447.62 | 0.574385E+09 | 544.92 | ||
| Maximum of Months | 0.502522E+09 | 447.62 | 0.663122E+09 | 544.92 |
Report: ZoneElectricSummaryMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
| January | 0.824800E+09 | 307.95 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.744981E+09 | 307.95 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.824800E+09 | 307.95 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.798194E+09 | 307.95 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.824800E+09 | 307.95 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.798194E+09 | 307.95 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 0.824800E+09 | 307.95 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 0.824800E+09 | 307.95 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 0.798194E+09 | 307.95 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 0.824800E+09 | 307.95 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.798194E+09 | 307.95 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.824800E+09 | 307.95 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.971136E+10 | 0.00 | 0.00 | ||
| Minimum of Months | 0.744981E+09 | 307.95 | 0.00 | 0.00 | |
| Maximum of Months | 0.824800E+09 | 307.95 | 0.00 | 0.00 |
Report: ZoneElectricSummaryMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.824800E+09 | 307.95 | 01-JAN-00:10 | 0.576651E+10 | 3803.87 | 01-JAN-07:10 |
| February | 0.744981E+09 | 307.95 | 01-FEB-00:10 | 0.520846E+10 | 3803.87 | 01-FEB-07:10 |
| March | 0.824800E+09 | 307.95 | 01-MAR-00:10 | 0.576651E+10 | 3803.87 | 01-MAR-07:10 |
| April | 0.798194E+09 | 307.95 | 01-APR-00:10 | 0.558049E+10 | 3803.87 | 01-APR-06:10 |
| May | 0.824800E+09 | 307.95 | 01-MAY-00:10 | 0.576651E+10 | 3803.87 | 01-MAY-06:10 |
| June | 0.798194E+09 | 307.95 | 01-JUN-00:10 | 0.558049E+10 | 3803.87 | 01-JUN-06:10 |
| July | 0.824800E+09 | 307.95 | 01-JUL-00:10 | 0.576651E+10 | 3803.87 | 01-JUL-06:10 |
| August | 0.824800E+09 | 307.95 | 01-AUG-00:10 | 0.576651E+10 | 3803.87 | 01-AUG-06:10 |
| September | 0.798194E+09 | 307.95 | 01-SEP-00:10 | 0.558049E+10 | 3803.87 | 01-SEP-06:10 |
| October | 0.824800E+09 | 307.95 | 01-OCT-00:10 | 0.576651E+10 | 3803.87 | 01-OCT-06:10 |
| November | 0.798194E+09 | 307.95 | 01-NOV-00:10 | 0.558049E+10 | 3803.87 | 01-NOV-06:10 |
| December | 0.824800E+09 | 307.95 | 01-DEC-00:10 | 0.576651E+10 | 3803.87 | 01-DEC-07:10 |
| Annual Sum or Average | 0.971136E+10 | 0.678960E+11 | ||||
| Minimum of Months | 0.744981E+09 | 307.95 | 0.520846E+10 | 3803.87 | ||
| Maximum of Months | 0.824800E+09 | 307.95 | 0.576651E+10 | 3803.87 |
Report: ZoneElectricSummaryMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
| January | 0.824800E+09 | 307.95 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.744981E+09 | 307.95 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.824800E+09 | 307.95 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.798194E+09 | 307.95 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.824800E+09 | 307.95 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.798194E+09 | 307.95 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 0.824800E+09 | 307.95 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 0.824800E+09 | 307.95 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 0.798194E+09 | 307.95 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 0.824800E+09 | 307.95 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.798194E+09 | 307.95 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.824800E+09 | 307.95 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.971136E+10 | 0.00 | 0.00 | ||
| Minimum of Months | 0.744981E+09 | 307.95 | 0.00 | 0.00 | |
| Maximum of Months | 0.824800E+09 | 307.95 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18974245.30 | 2350145.39 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 25214168.26 | 424299.48 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43604626.15 | 194767.15 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 40485451.68 | 6753.02 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45431522.76 | 60939.17 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 42350523.57 | 196040.03 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26536001.55 | 211484.83 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 33686156.53 | 362657.50 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23945343.07 | 233604.40 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19800584.44 | 302754.15 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15728218.87 | 851329.98 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14455100.19 | 3102345.44 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.350212E+09 | 8297120.55 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 14455100.19 | 6753.02 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45431522.76 | 3102345.44 |
Report: SpaceGainsMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18908589.27 | 2331547.09 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 25195552.17 | 427638.54 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43604744.54 | 191803.35 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 40485379.46 | 6919.35 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45431523.55 | 62452.23 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 42350459.06 | 202041.60 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26535991.27 | 200540.56 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 33686134.52 | 361842.52 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23945335.28 | 234541.34 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19799788.49 | 304724.41 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15722462.99 | 869196.00 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14419893.36 | 3071920.22 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.350086E+09 | 8265167.21 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 14419893.36 | 6919.35 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45431523.55 | 3071920.22 |
Report: SpaceGainsMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.227408E+09 | 0.468251E+09 | 0.621586E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 10228921.90 | 12304690.86 |
| February | 0.216037E+09 | 0.433623E+09 | 0.574385E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 13934924.38 | 6635419.22 |
| March | 0.261519E+09 | 0.502522E+09 | 0.663122E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 23561843.21 | 11401710.70 |
| April | 0.227408E+09 | 0.460516E+09 | 0.610467E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 19459990.81 | 4939973.72 |
| May | 0.250148E+09 | 0.491098E+09 | 0.649277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 25303521.74 | 5884976.78 |
| June | 0.250148E+09 | 0.483363E+09 | 0.638158E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 23206713.22 | 6409033.28 |
| July | 0.227408E+09 | 0.468251E+09 | 0.621586E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 13096058.44 | 5900441.38 |
| August | 0.261519E+09 | 0.502522E+09 | 0.663122E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 19043148.40 | 9948316.91 |
| September | 0.227408E+09 | 0.460516E+09 | 0.610467E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12979708.96 | 6036509.72 |
| October | 0.238778E+09 | 0.479675E+09 | 0.635432E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 10446987.81 | 7831251.84 |
| November | 0.227408E+09 | 0.460516E+09 | 0.610467E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 8897029.35 | 8330365.98 |
| December | 0.227408E+09 | 0.468251E+09 | 0.621586E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 7874366.50 | 11779902.03 |
| Annual Sum or Average | 0.284259E+10 | 0.567911E+10 | 0.751966E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.188033E+09 | 97402592.42 |
| Minimum of Months | 0.216037E+09 | 0.433623E+09 | 0.574385E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 7874366.50 | 4939973.72 |
| Maximum of Months | 0.261519E+09 | 0.502522E+09 | 0.663122E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 25303521.74 | 12304690.86 |
Report: SpaceGainsMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18905645.41 | 2389271.75 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 25192958.81 | 458748.90 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43604480.72 | 194677.50 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 40485476.41 | 6666.36 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45431524.11 | 61762.82 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 42350427.49 | 201245.23 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26535944.40 | 198711.35 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 33686108.57 | 363172.77 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23945329.78 | 235141.43 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19799737.62 | 305943.09 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15722061.93 | 887914.87 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14419346.30 | 3131134.87 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.350079E+09 | 8434390.94 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 14419346.30 | 6666.36 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45431524.11 | 3131134.87 |
Report: SpaceGainsMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11405325.36 | 1396027.35 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 15197470.12 | 249158.66 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26301225.79 | 113789.13 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24420023.65 | 3685.30 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27403153.16 | 35593.26 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25544749.36 | 117002.22 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16005774.70 | 113132.42 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20318481.79 | 210209.10 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14443207.81 | 136499.43 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11942668.30 | 179909.59 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9483202.94 | 517481.56 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8697231.75 | 1841129.27 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.211163E+09 | 4913617.30 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 8697231.75 | 3685.30 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27403153.16 | 1841129.27 |
Report: SpaceGainsMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11405269.58 | 1396578.79 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 15197437.79 | 249377.07 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26301223.66 | 113797.59 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24420024.75 | 3683.96 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27403153.36 | 35583.26 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25544747.36 | 116979.32 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16005774.14 | 113062.77 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20318480.96 | 210274.80 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14443207.63 | 136526.94 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11942665.76 | 179941.86 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9483193.90 | 517678.05 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8697172.04 | 1841624.51 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.211162E+09 | 4915108.93 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 8697172.04 | 3683.96 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27403153.36 | 1841624.51 |
Report: SpaceGainsMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11444628.96 | 1414850.41 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 15208251.29 | 250500.20 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26301137.34 | 116002.31 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24420120.47 | 3600.42 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27403153.02 | 34520.78 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25544858.89 | 113916.12 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16005788.33 | 117830.49 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20318468.97 | 210700.64 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14443215.25 | 136215.53 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11943124.40 | 179871.46 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9486663.10 | 510347.52 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8718342.05 | 1868431.61 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.211238E+09 | 4956787.50 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 8718342.05 | 3600.42 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27403153.02 | 1868431.61 |
Report: SpaceGainsMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11444489.11 | 1442919.00 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 15208139.21 | 261679.20 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26301087.59 | 119309.76 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24419995.68 | 3739.79 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27403149.63 | 35842.37 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25544821.59 | 117682.91 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16005783.70 | 121878.19 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20318529.54 | 219457.74 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14443218.28 | 140103.41 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11943144.62 | 187277.09 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9486673.92 | 525165.58 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8718445.04 | 1895456.09 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.211237E+09 | 5070511.13 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 8718445.04 | 3739.79 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27403149.63 | 1895456.09 |
Report: SpaceGainsMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27135811.69 | 3282056.16 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 36089031.25 | 557112.27 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 62409458.32 | 273287.14 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57972904.61 | 9570.69 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65063257.42 | 87318.36 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60652636.55 | 271784.45 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37973077.81 | 284256.27 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48188290.38 | 483479.17 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34261861.68 | 315606.10 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 28308895.67 | 410830.16 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22484774.07 | 1168918.94 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20671664.60 | 4330337.27 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.501212E+09 | 11474556.97 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 20671664.60 | 9570.69 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65063257.42 | 4330337.27 |
Report: SpaceGainsMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27047408.05 | 3224327.30 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 36066022.30 | 547489.61 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 62410076.69 | 269151.64 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57972686.32 | 9781.56 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65063260.38 | 89534.59 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60652208.93 | 279531.22 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37972902.23 | 272395.88 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48188255.90 | 480585.56 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34261838.06 | 314932.94 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 28307967.86 | 412203.93 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22478156.34 | 1177557.33 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20630713.15 | 4240956.29 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.501051E+09 | 11318447.84 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 20630713.15 | 9781.56 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65063260.38 | 4240956.29 |
Report: SpaceGainsMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27133679.19 | 3352874.55 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 36086471.41 | 600406.85 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 62408401.71 | 279316.50 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57973371.02 | 9070.09 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65063254.91 | 86013.22 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60652425.06 | 270855.01 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37972688.97 | 280149.19 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48188110.45 | 485542.83 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34261839.87 | 316478.48 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 28308700.97 | 413835.65 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22483843.90 | 1198335.11 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20670338.49 | 4408887.67 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.501203E+09 | 11701765.15 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 20670338.49 | 9070.09 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65063254.91 | 4408887.67 |
Report: SpaceGainsMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27038983.46 | 3331223.14 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 36059647.50 | 607241.88 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 62408588.86 | 275410.22 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57973118.18 | 9279.30 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65063258.48 | 88353.31 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60652138.14 | 278329.83 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37972612.46 | 270520.35 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48188048.40 | 482927.97 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34261832.27 | 316213.68 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 28307700.13 | 415083.25 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22475956.96 | 1213670.31 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20621231.75 | 4352774.74 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.501023E+09 | 11641027.99 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 20621231.75 | 9279.30 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65063258.48 | 4352774.74 |
Report: SpaceGainsMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16315524.11 | 1939332.61 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 21754868.28 | 320445.26 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37644023.89 | 160738.72 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34968376.81 | 5167.26 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39244601.48 | 50918.29 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36584050.67 | 162315.02 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22904138.55 | 153265.77 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29066095.55 | 280559.04 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20665862.77 | 183635.45 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17074507.98 | 244234.25 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13557655.65 | 704179.78 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12443653.84 | 2553492.45 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.302223E+09 | 6758283.89 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12443653.84 | 5167.26 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39244601.48 | 2553492.45 |
Report: SpaceGainsMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16315176.91 | 1940364.68 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 21754723.27 | 320978.39 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37644010.78 | 160753.92 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34968380.81 | 5164.57 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39244601.70 | 50896.56 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36584045.78 | 162274.78 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22904135.51 | 153216.14 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29066079.42 | 280645.31 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20665862.51 | 183664.55 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17074505.09 | 244281.74 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13557633.86 | 704707.25 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12443470.04 | 2554461.04 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.302223E+09 | 6761408.92 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12443470.04 | 5164.57 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39244601.70 | 2554461.04 |
Report: SpaceGainsMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16367199.77 | 1981873.06 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 21767438.46 | 330735.15 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37643609.66 | 163425.46 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34968557.88 | 5040.22 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39244612.07 | 48899.19 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36584390.82 | 157627.35 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22904233.70 | 156363.43 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29066258.38 | 281716.80 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20665885.22 | 183904.00 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17075122.95 | 244288.44 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13561761.82 | 704016.13 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12467652.99 | 2617918.32 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.302317E+09 | 6875807.55 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12467652.99 | 5040.22 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39244612.07 | 2617918.32 |
Report: SpaceGainsMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16367169.79 | 1982413.56 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 21767415.73 | 331103.74 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37643597.82 | 163440.99 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34968562.41 | 5037.15 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39244612.19 | 48870.73 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36584381.38 | 157569.41 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22904229.54 | 156241.79 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29066233.19 | 281796.68 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20665884.34 | 183933.91 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17075121.68 | 244333.71 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13561750.19 | 704302.54 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12467643.16 | 2618740.55 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.302317E+09 | 6877784.75 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12467643.16 | 5037.15 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39244612.19 | 2618740.55 |
Report: SpaceGainsMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 35542750.19 | 4333866.03 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 47348472.90 | 740360.39 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 81881251.92 | 382113.30 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 76134745.43 | 15008.22 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 85469888.38 | 137486.38 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79678082.09 | 394714.60 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 49803203.82 | 436387.43 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 63156944.79 | 704991.14 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 44926530.31 | 462588.63 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37060486.50 | 593977.36 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29429513.06 | 1582825.08 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27073818.77 | 5750257.99 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.657506E+09 | 15534576.57 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 27073818.77 | 15008.22 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 85469888.38 | 5750257.99 |
Report: SpaceGainsMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 35422238.66 | 4272465.38 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 47315652.13 | 731820.97 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 81881359.86 | 377767.30 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 76134546.87 | 15382.18 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 85469909.01 | 140238.30 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79677898.53 | 405984.34 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 49802934.09 | 415136.60 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 63156914.45 | 698777.98 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 44926481.21 | 462800.45 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37059192.47 | 603840.64 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29420524.73 | 1612022.96 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27016384.85 | 5637272.56 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.657284E+09 | 15373509.66 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 27016384.85 | 15382.18 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 85469909.01 | 5637272.56 |
Report: SpaceGainsMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 35539139.21 | 4482274.27 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 47344093.85 | 828319.05 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 81879560.91 | 393508.28 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 76135213.83 | 13855.62 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 85469861.23 | 135163.09 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79677948.15 | 392124.53 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 49802637.50 | 427333.16 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 63156579.54 | 706687.37 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 44926294.19 | 462248.89 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37060274.96 | 598030.17 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29427694.18 | 1634851.22 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27070801.69 | 5902366.37 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.657490E+09 | 15976762.03 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 27070801.69 | 13855.62 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 85469861.23 | 5902366.37 |
Report: SpaceGainsMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 35409800.60 | 4486800.88 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 47304897.92 | 854269.31 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 81879771.01 | 389624.44 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 76134992.48 | 14202.07 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 85469866.48 | 137825.99 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79677752.74 | 402624.30 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 49802584.07 | 410448.77 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 63156528.98 | 700950.94 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 44926270.93 | 462575.47 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37058896.86 | 608024.51 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29417862.55 | 1676093.50 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27008659.92 | 5848659.23 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.657248E+09 | 15992099.40 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 27008659.92 | 14202.07 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 85469866.48 | 5848659.23 |
Report: SpaceGainsMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21364970.65 | 2606722.13 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 28538571.45 | 446137.15 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 49388317.45 | 230038.40 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45922924.07 | 8121.96 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 51553235.47 | 81164.00 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48059697.49 | 239044.72 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30039670.56 | 235201.70 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38094273.02 | 412273.11 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27098328.93 | 274186.82 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22352975.30 | 365761.39 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17744821.29 | 981219.13 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16292866.96 | 3438030.25 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.396451E+09 | 9317900.77 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16292866.96 | 8121.96 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 51553235.47 | 3438030.25 |
Report: SpaceGainsMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21364538.49 | 2610845.92 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 28538346.69 | 447897.66 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 49388284.95 | 230100.44 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45922939.40 | 8104.79 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 51553235.49 | 81098.61 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48059691.84 | 238829.58 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30039663.47 | 235047.28 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38094265.74 | 412389.41 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27098327.96 | 274117.69 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22352967.28 | 365839.50 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17744761.98 | 981997.44 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16292482.90 | 3440963.91 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.396450E+09 | 9327232.24 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16292482.90 | 8104.79 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 51553235.49 | 3440963.91 |
Report: SpaceGainsMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21437418.91 | 2644889.02 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 28557758.43 | 451376.43 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 49388036.57 | 232811.56 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45923150.98 | 7922.82 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 51553235.77 | 79302.66 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48059961.91 | 232103.11 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30039775.93 | 243058.00 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38094348.50 | 416452.35 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27098337.17 | 275201.60 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22353785.86 | 360429.13 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17750253.26 | 965525.93 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16328966.22 | 3508385.61 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.396585E+09 | 9417458.21 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16328966.22 | 7922.82 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 51553235.77 | 3508385.61 |
Report: SpaceGainsMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21437359.84 | 2646638.56 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 28557692.06 | 452360.86 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 49388019.18 | 232881.25 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45923169.17 | 7905.78 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 51553236.94 | 79235.34 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48059953.39 | 231932.67 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30039767.46 | 242694.56 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38094342.96 | 416545.59 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27098337.65 | 275000.22 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22353782.09 | 360487.55 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17750245.93 | 966394.70 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16328933.67 | 3510055.96 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.396585E+09 | 9422133.04 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16328933.67 | 7905.78 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 51553236.94 | 3510055.96 |
Report: SpaceGainsMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2693286.23 | 1669850.62 |
| February | 0.657255E+09 | 0.744981E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4068918.85 | 500722.61 |
| March | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7206435.14 | 614264.02 |
| April | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7147419.85 | 97182.82 |
| May | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8431771.74 | 430640.08 |
| June | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7615871.93 | 432174.82 |
| July | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4280968.66 | 543920.88 |
| August | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5405055.25 | 837230.26 |
| September | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3887861.39 | 552581.83 |
| October | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2892267.66 | 813046.48 |
| November | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2216037.36 | 968137.37 |
| December | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1992872.01 | 1980587.59 |
| Annual Sum or Average | 0.856778E+10 | 0.971136E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 57838766.06 | 9440339.38 |
| Minimum of Months | 0.657255E+09 | 0.744981E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1992872.01 | 97182.82 |
| Maximum of Months | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8431771.74 | 1980587.59 |
Report: SpaceGainsMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.192150E+09 | 0.300310E+09 |
| February | 0.657255E+09 | 0.744981E+09 | 0.260423E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.263897E+09 | 0.204285E+09 |
| March | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.364395E+09 | 0.128066E+09 |
| April | 0.704201E+09 | 0.798194E+09 | 0.279025E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.405991E+09 | 70227428.63 |
| May | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.439513E+09 | 89997247.15 |
| June | 0.704201E+09 | 0.798194E+09 | 0.279025E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.409996E+09 | 99772352.91 |
| July | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.223942E+09 | 0.214191E+09 |
| August | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.235456E+09 | 0.176960E+09 |
| September | 0.704201E+09 | 0.798194E+09 | 0.279025E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.231320E+09 | 0.175528E+09 |
| October | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.152635E+09 | 0.215259E+09 |
| November | 0.704201E+09 | 0.798194E+09 | 0.279025E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.140710E+09 | 0.230343E+09 |
| December | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.138078E+09 | 0.299510E+09 |
| Annual Sum or Average | 0.856778E+10 | 0.971136E+10 | 0.339480E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.319808E+10 | 0.220445E+10 |
| Minimum of Months | 0.657255E+09 | 0.744981E+09 | 0.260423E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.138078E+09 | 70227428.63 |
| Maximum of Months | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.439513E+09 | 0.300310E+09 |
Report: SpaceGainsMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2424502.86 | 1285194.40 |
| February | 0.657255E+09 | 0.744981E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3571489.07 | 384425.42 |
| March | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6224365.14 | 463186.34 |
| April | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6147635.09 | 71711.53 |
| May | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7182115.83 | 285719.82 |
| June | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6530335.04 | 283413.39 |
| July | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3779270.99 | 341319.77 |
| August | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4664152.02 | 553828.65 |
| September | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3410153.17 | 348709.43 |
| October | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2581767.38 | 559281.37 |
| November | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1985052.17 | 724187.43 |
| December | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1802474.79 | 1521841.53 |
| Annual Sum or Average | 0.856778E+10 | 0.971136E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50303313.55 | 6822819.08 |
| Minimum of Months | 0.657255E+09 | 0.744981E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1802474.79 | 71711.53 |
| Maximum of Months | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7182115.83 | 1521841.53 |
Report: PeakSpaceGainsMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 47.23 | 04-JAN-13:00 | 33.35 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 63.61 | 28-FEB-15:00 | 12.96 | 01-FEB-07:10 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.57 | 19-MAR-16:00 | 6.23 | 03-MAR-06:30 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.38 | 04-APR-14:00 | 6.44 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 84.07 | 06-MAY-15:00 | 8.46 | 31-MAY-21:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 74.91 | 16-JUN-15:00 | 16.02 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 56.49 | 01-JUL-13:00 | 14.88 | 19-JUL-19:40 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.77 | 06-AUG-13:00 | 17.27 | 23-AUG-20:10 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 67.76 | 10-SEP-15:00 | 16.10 | 15-SEP-17:20 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 59.45 | 29-OCT-13:10 | 11.89 | 30-OCT-17:00 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 39.71 | 10-NOV-13:00 | 12.20 | 25-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 46.28 | 09-DEC-14:00 | 19.51 | 21-DEC-07:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 39.71 | 6.23 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 89.57 | 33.35 |
Report: PeakSpaceGainsMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 47.23 | 04-JAN-13:00 | 33.35 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 63.61 | 28-FEB-15:00 | 12.28 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.57 | 19-MAR-16:00 | 6.09 | 03-MAR-06:30 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.38 | 04-APR-14:00 | 6.52 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 84.07 | 06-MAY-15:00 | 8.91 | 31-MAY-21:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 74.91 | 16-JUN-15:00 | 17.43 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 56.49 | 01-JUL-13:00 | 16.00 | 19-JUL-19:10 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.77 | 06-AUG-13:00 | 17.68 | 23-AUG-20:10 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 67.76 | 10-SEP-15:00 | 15.89 | 15-SEP-17:20 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 59.45 | 29-OCT-13:10 | 11.37 | 30-OCT-17:00 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 39.71 | 10-NOV-13:00 | 10.95 | 25-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 46.28 | 09-DEC-14:00 | 18.84 | 21-DEC-07:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 39.71 | 6.09 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 89.57 | 33.35 |
Report: PeakSpaceGainsMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 451.21 | 03-JAN-08:09 | 447.62 | 03-JAN-08:09 | 544.92 | 03-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 47.23 | 04-JAN-13:00 | 97.00 | 07-JAN-05:00 |
| February | 451.21 | 01-FEB-08:09 | 447.62 | 01-FEB-08:09 | 544.92 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 63.61 | 28-FEB-15:00 | 20.87 | 01-FEB-07:00 |
| March | 451.21 | 01-MAR-08:09 | 447.62 | 01-MAR-08:09 | 544.92 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 65.19 | 17-MAR-15:00 | 22.48 | 14-MAR-22:00 |
| April | 451.21 | 03-APR-07:10 | 447.62 | 03-APR-07:10 | 544.92 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.38 | 04-APR-14:00 | 19.37 | 09-APR-16:00 |
| May | 451.21 | 01-MAY-07:10 | 447.62 | 01-MAY-07:10 | 544.92 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 68.90 | 04-MAY-13:00 | 41.77 | 08-MAY-22:00 |
| June | 451.21 | 01-JUN-07:10 | 447.62 | 01-JUN-07:10 | 544.92 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 74.90 | 16-JUN-15:00 | 44.25 | 20-JUN-23:00 |
| July | 451.21 | 03-JUL-07:10 | 447.62 | 03-JUL-07:10 | 544.92 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.35 | 05-JUL-14:00 | 24.54 | 19-JUL-18:53 |
| August | 451.21 | 01-AUG-07:10 | 447.62 | 01-AUG-07:10 | 544.92 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 52.98 | 24-AUG-13:00 | 35.66 | 23-AUG-19:53 |
| September | 451.21 | 01-SEP-07:10 | 447.62 | 01-SEP-07:10 | 544.92 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 47.34 | 14-SEP-13:00 | 32.23 | 15-SEP-17:00 |
| October | 451.21 | 02-OCT-07:10 | 447.62 | 02-OCT-07:10 | 544.92 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 43.90 | 04-OCT-15:00 | 20.01 | 29-OCT-17:30 |
| November | 451.21 | 01-NOV-07:10 | 447.62 | 01-NOV-07:10 | 544.92 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 39.71 | 10-NOV-13:00 | 19.55 | 26-NOV-10:00 |
| December | 451.21 | 01-DEC-08:09 | 447.62 | 01-DEC-08:09 | 544.92 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 33.06 | 19-DEC-14:00 | 25.86 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 451.21 | 447.62 | 544.92 | 0.00 | 0.00 | 0.00 | 0.00 | 33.06 | 19.37 | |||||
| Maximum of Months | 451.21 | 447.62 | 544.92 | 0.00 | 0.00 | 0.00 | 0.00 | 74.90 | 97.00 |
Report: PeakSpaceGainsMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 47.23 | 04-JAN-13:00 | 33.35 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 63.61 | 28-FEB-15:00 | 12.62 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.57 | 19-MAR-16:00 | 6.10 | 03-MAR-06:30 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.38 | 04-APR-14:00 | 6.39 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 84.07 | 06-MAY-15:00 | 8.74 | 31-MAY-21:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 74.91 | 16-JUN-15:00 | 17.06 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 56.49 | 01-JUL-13:00 | 14.90 | 03-JUL-13:20 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.77 | 06-AUG-13:00 | 17.19 | 23-AUG-20:10 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 67.76 | 10-SEP-15:00 | 15.72 | 15-SEP-17:20 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 59.45 | 29-OCT-13:10 | 11.39 | 30-OCT-17:00 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 39.71 | 10-NOV-13:00 | 12.06 | 25-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 46.28 | 09-DEC-14:00 | 19.17 | 21-DEC-07:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 39.71 | 6.10 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 89.57 | 33.35 |
Report: PeakSpaceGainsMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 28.49 | 04-JAN-13:00 | 20.12 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.37 | 28-FEB-15:00 | 7.25 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 54.03 | 19-MAR-16:00 | 3.58 | 03-MAR-06:30 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.99 | 04-APR-14:00 | 3.63 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.71 | 06-MAY-15:00 | 4.91 | 31-MAY-21:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.19 | 16-JUN-15:00 | 9.79 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 34.07 | 01-JUL-13:00 | 8.41 | 19-JUL-19:20 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.26 | 06-AUG-13:00 | 9.72 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 40.87 | 10-SEP-15:00 | 8.75 | 15-SEP-21:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 35.86 | 29-OCT-13:10 | 6.80 | 30-OCT-16:10 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.95 | 10-NOV-13:00 | 6.55 | 25-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 27.92 | 09-DEC-14:00 | 11.44 | 21-DEC-07:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 23.95 | 3.58 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 54.03 | 20.12 |
Report: PeakSpaceGainsMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 28.49 | 04-JAN-13:00 | 20.12 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.37 | 28-FEB-15:00 | 7.25 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 54.03 | 19-MAR-16:00 | 3.58 | 03-MAR-06:30 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.99 | 04-APR-14:00 | 3.63 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.71 | 06-MAY-15:00 | 4.91 | 31-MAY-21:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.19 | 16-JUN-15:00 | 9.78 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 34.07 | 01-JUL-13:00 | 8.40 | 19-JUL-19:20 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.26 | 06-AUG-13:00 | 9.73 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 40.87 | 10-SEP-15:00 | 8.75 | 15-SEP-21:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 35.86 | 29-OCT-13:10 | 6.80 | 30-OCT-16:10 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.95 | 10-NOV-13:00 | 6.56 | 25-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 27.92 | 09-DEC-14:00 | 11.45 | 21-DEC-07:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 23.95 | 3.58 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 54.03 | 20.12 |
Report: PeakSpaceGainsMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 28.49 | 04-JAN-13:00 | 20.12 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.37 | 28-FEB-15:00 | 7.66 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 54.03 | 19-MAR-16:00 | 3.68 | 03-MAR-06:30 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.99 | 04-APR-14:00 | 3.58 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.71 | 06-MAY-15:00 | 4.59 | 31-MAY-21:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.19 | 16-JUN-15:00 | 9.00 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 34.07 | 01-JUL-13:00 | 7.88 | 19-JUL-19:40 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.26 | 06-AUG-13:00 | 9.79 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 40.87 | 10-SEP-15:00 | 8.90 | 15-SEP-17:20 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 35.86 | 29-OCT-13:10 | 6.89 | 30-OCT-17:00 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.95 | 10-NOV-13:00 | 7.34 | 25-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 27.92 | 09-DEC-14:00 | 11.88 | 21-DEC-07:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 23.95 | 3.58 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 54.03 | 20.12 |
Report: PeakSpaceGainsMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 28.49 | 04-JAN-13:00 | 20.12 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.37 | 28-FEB-15:00 | 8.00 | 01-FEB-07:10 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 54.03 | 19-MAR-16:00 | 3.83 | 03-MAR-06:30 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.99 | 04-APR-14:00 | 3.67 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.71 | 06-MAY-15:00 | 4.84 | 31-MAY-21:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.19 | 16-JUN-15:00 | 9.50 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 34.07 | 01-JUL-13:00 | 8.15 | 19-JUL-19:40 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.26 | 06-AUG-13:00 | 10.20 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 40.87 | 10-SEP-15:00 | 9.27 | 15-SEP-17:20 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 35.86 | 29-OCT-13:10 | 7.32 | 30-OCT-17:00 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.95 | 10-NOV-13:00 | 7.61 | 25-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 27.92 | 09-DEC-14:00 | 12.05 | 21-DEC-07:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 23.95 | 3.67 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 54.03 | 20.12 |
Report: PeakSpaceGainsMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 67.73 | 04-JAN-13:00 | 48.43 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 91.25 | 28-FEB-15:00 | 17.41 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 128.48 | 19-MAR-16:00 | 8.49 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 73.69 | 04-APR-14:00 | 8.87 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.63 | 06-MAY-15:00 | 10.86 | 31-MAY-21:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 107.39 | 16-JUN-15:00 | 21.28 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 81.00 | 01-JUL-13:00 | 19.74 | 19-JUL-19:40 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 88.53 | 06-AUG-13:00 | 22.26 | 23-AUG-20:10 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 97.13 | 10-SEP-15:00 | 20.76 | 15-SEP-17:10 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 85.22 | 29-OCT-13:10 | 16.34 | 30-OCT-16:10 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 56.90 | 10-NOV-13:00 | 15.48 | 25-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 66.32 | 09-DEC-14:00 | 26.78 | 21-DEC-07:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 56.90 | 8.49 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 128.48 | 48.43 |
Report: PeakSpaceGainsMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 67.73 | 04-JAN-13:00 | 48.43 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 91.25 | 28-FEB-15:00 | 16.62 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 128.48 | 19-MAR-16:00 | 8.49 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 73.69 | 04-APR-14:00 | 8.99 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.63 | 06-MAY-15:00 | 11.58 | 31-MAY-21:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 107.39 | 16-JUN-15:00 | 23.16 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 81.00 | 01-JUL-13:00 | 21.44 | 19-JUL-19:10 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 88.53 | 06-AUG-13:00 | 23.06 | 23-AUG-20:10 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 97.13 | 10-SEP-15:00 | 20.45 | 15-SEP-17:10 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 85.22 | 29-OCT-13:10 | 16.26 | 30-OCT-16:10 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 56.90 | 10-NOV-13:00 | 13.99 | 25-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 66.32 | 09-DEC-14:00 | 25.81 | 21-DEC-07:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 56.90 | 8.49 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 128.48 | 48.43 |
Report: PeakSpaceGainsMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 67.73 | 04-JAN-13:00 | 48.43 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 91.25 | 28-FEB-15:00 | 18.09 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 128.48 | 19-MAR-16:00 | 8.49 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 73.69 | 04-APR-14:00 | 8.56 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.63 | 06-MAY-15:00 | 10.54 | 31-MAY-21:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 107.39 | 16-JUN-15:00 | 20.02 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 81.00 | 01-JUL-13:00 | 18.29 | 19-JUL-19:40 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 88.53 | 06-AUG-13:00 | 22.28 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 97.13 | 10-SEP-15:00 | 20.41 | 15-SEP-17:10 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 85.22 | 29-OCT-13:10 | 16.34 | 30-OCT-16:10 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 56.90 | 10-NOV-13:00 | 17.29 | 25-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 66.32 | 09-DEC-14:00 | 27.37 | 21-DEC-07:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 56.90 | 8.49 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 128.48 | 48.43 |
Report: PeakSpaceGainsMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 67.73 | 04-JAN-13:00 | 48.43 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 91.25 | 28-FEB-15:00 | 17.30 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 128.48 | 19-MAR-16:00 | 8.49 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 73.69 | 04-APR-14:00 | 8.67 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.63 | 06-MAY-15:00 | 11.26 | 31-MAY-21:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 107.39 | 16-JUN-15:00 | 22.47 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 81.00 | 01-JUL-13:00 | 19.75 | 19-JUL-19:20 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 88.53 | 06-AUG-13:00 | 22.07 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 97.13 | 10-SEP-15:00 | 20.10 | 15-SEP-17:10 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 85.22 | 29-OCT-13:10 | 16.31 | 30-OCT-16:10 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 56.90 | 10-NOV-13:00 | 15.42 | 25-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 66.32 | 09-DEC-14:00 | 26.40 | 21-DEC-07:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 56.90 | 8.49 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 128.48 | 48.43 |
Report: PeakSpaceGainsMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 40.86 | 04-JAN-13:00 | 29.21 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 55.04 | 28-FEB-15:00 | 9.91 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 77.50 | 19-MAR-16:00 | 5.12 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.45 | 04-APR-14:00 | 4.95 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 72.76 | 06-MAY-15:00 | 6.33 | 31-MAY-21:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.77 | 16-JUN-15:00 | 12.80 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.85 | 01-JUL-13:00 | 11.08 | 19-JUL-19:20 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 53.40 | 06-AUG-13:00 | 13.01 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.59 | 10-SEP-15:00 | 11.78 | 15-SEP-21:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.40 | 29-OCT-13:10 | 9.35 | 30-OCT-16:10 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 34.32 | 10-NOV-13:00 | 8.47 | 25-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 40.00 | 09-DEC-14:00 | 15.83 | 21-DEC-07:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 34.32 | 4.95 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 77.50 | 29.21 |
Report: PeakSpaceGainsMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 40.86 | 04-JAN-13:00 | 29.21 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 55.04 | 28-FEB-15:00 | 9.91 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 77.50 | 19-MAR-16:00 | 5.12 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.45 | 04-APR-14:00 | 4.94 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 72.76 | 06-MAY-15:00 | 6.33 | 31-MAY-21:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.77 | 16-JUN-15:00 | 12.78 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.85 | 01-JUL-13:00 | 11.08 | 19-JUL-19:40 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 53.40 | 06-AUG-13:00 | 13.02 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.59 | 10-SEP-15:00 | 11.78 | 15-SEP-21:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.40 | 29-OCT-13:10 | 9.36 | 30-OCT-16:10 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 34.32 | 10-NOV-13:00 | 8.48 | 25-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 40.00 | 09-DEC-14:00 | 15.83 | 21-DEC-07:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 34.32 | 4.94 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 77.50 | 29.21 |
Report: PeakSpaceGainsMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 40.86 | 04-JAN-13:00 | 29.21 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 55.04 | 28-FEB-15:00 | 10.42 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 77.50 | 19-MAR-16:00 | 5.12 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.45 | 04-APR-14:00 | 4.87 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 72.76 | 06-MAY-15:00 | 5.80 | 31-MAY-21:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.77 | 16-JUN-15:00 | 11.61 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.85 | 01-JUL-13:00 | 10.07 | 19-JUL-20:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 53.40 | 06-AUG-13:00 | 13.14 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.59 | 10-SEP-15:00 | 11.81 | 15-SEP-21:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.40 | 29-OCT-13:10 | 9.67 | 30-OCT-16:10 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 34.32 | 10-NOV-13:00 | 9.54 | 25-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 40.00 | 09-DEC-14:00 | 16.44 | 21-DEC-07:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 34.32 | 4.87 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 77.50 | 29.21 |
Report: PeakSpaceGainsMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 40.86 | 04-JAN-13:00 | 29.21 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 55.04 | 28-FEB-15:00 | 10.42 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 77.50 | 19-MAR-16:00 | 5.12 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.45 | 04-APR-14:00 | 4.87 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 72.76 | 06-MAY-15:00 | 5.79 | 31-MAY-21:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.77 | 16-JUN-15:00 | 11.60 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.85 | 01-JUL-13:00 | 10.05 | 19-JUL-20:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 53.40 | 06-AUG-13:00 | 13.15 | 20-AUG-11:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.59 | 10-SEP-15:00 | 11.81 | 15-SEP-21:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.40 | 29-OCT-13:10 | 9.67 | 30-OCT-16:10 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 34.32 | 10-NOV-13:00 | 9.55 | 25-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 40.00 | 09-DEC-14:00 | 16.45 | 21-DEC-07:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 34.32 | 4.87 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 77.50 | 29.21 |
Report: PeakSpaceGainsMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.24 | 04-JAN-13:00 | 65.38 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.27 | 28-FEB-15:00 | 22.07 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 169.33 | 19-MAR-16:00 | 11.45 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 97.09 | 04-APR-14:00 | 12.26 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 159.08 | 06-MAY-15:00 | 16.01 | 31-MAY-21:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 141.35 | 16-JUN-15:00 | 32.44 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 106.64 | 01-JUL-13:00 | 31.51 | 19-JUL-20:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 116.47 | 06-AUG-13:00 | 32.79 | 23-AUG-20:10 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 127.84 | 10-SEP-15:00 | 30.57 | 15-SEP-17:20 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 112.14 | 29-OCT-13:10 | 22.26 | 30-OCT-15:50 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 74.84 | 10-NOV-13:00 | 20.19 | 25-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 87.23 | 09-DEC-14:00 | 34.90 | 20-DEC-22:50 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 74.84 | 11.45 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 169.33 | 65.38 |
Report: PeakSpaceGainsMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.24 | 04-JAN-13:00 | 65.39 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.27 | 28-FEB-15:00 | 21.17 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 169.33 | 19-MAR-16:00 | 11.45 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 97.09 | 04-APR-14:00 | 12.43 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 159.08 | 06-MAY-15:00 | 16.97 | 31-MAY-21:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 141.35 | 16-JUN-15:00 | 35.12 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 106.64 | 01-JUL-13:00 | 32.96 | 19-JUL-19:20 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 116.47 | 06-AUG-13:00 | 34.21 | 23-AUG-20:10 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 127.84 | 10-SEP-15:00 | 29.13 | 15-SEP-17:20 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 112.14 | 29-OCT-13:10 | 22.00 | 30-OCT-15:50 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 74.84 | 10-NOV-13:00 | 19.64 | 26-NOV-10:10 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 87.23 | 09-DEC-14:00 | 34.22 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 74.84 | 11.45 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 169.33 | 65.39 |
Report: PeakSpaceGainsMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.24 | 04-JAN-13:00 | 65.38 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.27 | 28-FEB-15:00 | 23.35 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 169.33 | 19-MAR-16:00 | 11.45 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 97.09 | 04-APR-14:00 | 11.60 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 159.08 | 06-MAY-15:00 | 15.31 | 31-MAY-21:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 141.35 | 16-JUN-15:00 | 31.08 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 106.64 | 01-JUL-13:00 | 30.00 | 03-JUL-13:20 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 116.47 | 06-AUG-13:00 | 31.29 | 23-AUG-20:10 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 127.84 | 10-SEP-15:00 | 29.24 | 15-SEP-17:20 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 112.14 | 29-OCT-13:10 | 22.23 | 30-OCT-15:50 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 74.84 | 10-NOV-13:00 | 24.32 | 25-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 87.23 | 09-DEC-14:00 | 34.74 | 20-DEC-22:50 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 74.84 | 11.45 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 169.33 | 65.38 |
Report: PeakSpaceGainsMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.24 | 04-JAN-13:00 | 65.39 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.27 | 28-FEB-15:00 | 22.43 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 169.33 | 19-MAR-16:00 | 11.45 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 97.09 | 04-APR-14:00 | 11.77 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 159.08 | 06-MAY-15:00 | 16.17 | 31-MAY-21:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 141.35 | 16-JUN-15:00 | 33.69 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 106.64 | 01-JUL-13:00 | 32.37 | 03-JUL-13:20 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 116.47 | 06-AUG-13:00 | 32.05 | 23-AUG-20:10 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 127.84 | 10-SEP-15:00 | 28.40 | 15-SEP-21:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 112.14 | 29-OCT-13:10 | 21.97 | 30-OCT-15:50 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 74.84 | 10-NOV-13:00 | 20.90 | 25-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 87.23 | 09-DEC-14:00 | 34.22 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 74.84 | 11.45 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 169.33 | 65.39 |
Report: PeakSpaceGainsMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 53.83 | 04-JAN-13:00 | 39.44 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 72.54 | 28-FEB-15:00 | 12.88 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 102.13 | 19-MAR-16:00 | 6.91 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.56 | 04-APR-14:00 | 6.83 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 95.95 | 06-MAY-15:00 | 9.49 | 31-MAY-21:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 85.26 | 16-JUN-15:00 | 20.11 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.33 | 01-JUL-13:00 | 17.31 | 19-JUL-19:20 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 70.25 | 06-AUG-13:00 | 18.17 | 23-AUG-20:10 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 77.11 | 10-SEP-15:00 | 17.13 | 15-SEP-21:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 67.64 | 29-OCT-13:10 | 13.25 | 30-OCT-16:06 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.14 | 10-NOV-13:00 | 11.59 | 26-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 52.62 | 09-DEC-14:00 | 20.64 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 45.14 | 6.83 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 102.13 | 39.44 |
Report: PeakSpaceGainsMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 53.83 | 04-JAN-13:00 | 39.44 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 72.54 | 28-FEB-15:00 | 12.88 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 102.13 | 19-MAR-16:00 | 6.91 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.56 | 04-APR-14:00 | 6.81 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 95.95 | 06-MAY-15:00 | 9.47 | 31-MAY-21:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 85.26 | 16-JUN-15:00 | 20.05 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.33 | 01-JUL-13:00 | 17.25 | 19-JUL-19:20 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 70.25 | 06-AUG-13:00 | 18.13 | 23-AUG-20:10 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 77.11 | 10-SEP-15:00 | 17.13 | 15-SEP-21:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 67.64 | 29-OCT-13:10 | 13.25 | 30-OCT-16:06 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.14 | 10-NOV-13:00 | 11.61 | 26-NOV-10:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 52.62 | 09-DEC-14:00 | 20.64 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 45.14 | 6.81 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 102.13 | 39.44 |
Report: PeakSpaceGainsMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 53.83 | 04-JAN-13:00 | 39.44 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 72.54 | 28-FEB-15:00 | 13.45 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 102.13 | 19-MAR-16:00 | 6.91 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.56 | 04-APR-14:00 | 6.72 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 95.95 | 06-MAY-15:00 | 8.86 | 31-MAY-21:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 85.26 | 16-JUN-15:00 | 18.16 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.33 | 01-JUL-13:00 | 16.70 | 19-JUL-20:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 70.25 | 06-AUG-13:00 | 17.69 | 23-AUG-20:10 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 77.11 | 10-SEP-15:00 | 17.13 | 15-SEP-21:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 67.64 | 29-OCT-13:10 | 13.25 | 30-OCT-16:06 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.14 | 10-NOV-13:00 | 12.72 | 25-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 52.62 | 09-DEC-14:00 | 21.05 | 20-DEC-22:50 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 45.14 | 6.72 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 102.13 | 39.44 |
Report: PeakSpaceGainsMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 53.83 | 04-JAN-13:00 | 39.44 | 07-JAN-05:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 72.54 | 28-FEB-15:00 | 13.45 | 01-FEB-07:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 102.13 | 19-MAR-16:00 | 6.91 | 03-MAR-06:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.56 | 04-APR-14:00 | 6.71 | 14-APR-16:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 95.95 | 06-MAY-15:00 | 8.84 | 31-MAY-21:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 85.26 | 16-JUN-15:00 | 18.11 | 25-JUN-21:00 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.33 | 01-JUL-13:00 | 16.61 | 19-JUL-20:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 70.25 | 06-AUG-13:00 | 17.65 | 23-AUG-20:10 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 77.11 | 10-SEP-15:00 | 17.13 | 15-SEP-21:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 67.64 | 29-OCT-13:10 | 13.25 | 30-OCT-16:06 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.14 | 10-NOV-13:00 | 13.00 | 25-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 52.62 | 09-DEC-14:00 | 21.05 | 20-DEC-22:50 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 45.14 | 6.71 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 102.13 | 39.44 |
Report: PeakSpaceGainsMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.03 | 04-JAN-13:00 | 19.81 | 07-JAN-05:00 |
| February | 397.10 | 01-FEB-00:10 | 307.95 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.97 | 28-FEB-15:00 | 4.55 | 01-FEB-07:00 |
| March | 397.10 | 01-MAR-00:10 | 307.95 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.06 | 19-MAR-16:00 | 4.30 | 14-MAR-22:00 |
| April | 397.10 | 01-APR-00:10 | 307.95 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.83 | 04-APR-14:00 | 3.15 | 14-APR-15:53 |
| May | 397.10 | 01-MAY-00:10 | 307.95 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.22 | 06-MAY-15:00 | 7.88 | 08-MAY-22:00 |
| June | 397.10 | 01-JUN-00:10 | 307.95 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.30 | 16-JUN-14:30 | 7.88 | 20-JUN-23:00 |
| July | 397.10 | 01-JUL-00:10 | 307.95 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.47 | 01-JUL-13:00 | 7.74 | 03-JUL-13:00 |
| August | 397.10 | 01-AUG-00:10 | 307.95 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.06 | 06-AUG-13:00 | 8.42 | 23-AUG-19:53 |
| September | 397.10 | 01-SEP-00:10 | 307.95 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.67 | 10-SEP-15:00 | 10.32 | 15-SEP-16:53 |
| October | 397.10 | 01-OCT-00:10 | 307.95 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.27 | 29-OCT-13:00 | 4.24 | 30-OCT-16:40 |
| November | 397.10 | 01-NOV-00:10 | 307.95 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.37 | 10-NOV-12:00 | 3.69 | 25-NOV-08:00 |
| December | 397.10 | 01-DEC-00:10 | 307.95 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.13 | 09-DEC-14:00 | 7.18 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.37 | 3.15 | ||||
| Maximum of Months | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.22 | 19.81 |
Report: PeakSpaceGainsMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 | 190.19 | 01-JAN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1776.64 | 03-JAN-17:02 | 4059.72 | 24-JAN-07:01 |
| February | 397.10 | 01-FEB-00:10 | 307.95 | 01-FEB-00:10 | 190.19 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2172.64 | 24-FEB-17:02 | 3297.67 | 02-FEB-07:01 |
| March | 397.10 | 01-MAR-00:10 | 307.95 | 01-MAR-00:10 | 190.19 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2769.85 | 19-MAR-16:02 | 2199.61 | 15-MAR-06:01 |
| April | 397.10 | 01-APR-00:10 | 307.95 | 01-APR-00:10 | 190.19 | 01-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2967.47 | 11-APR-16:02 | 1771.97 | 14-APR-16:03 |
| May | 397.10 | 01-MAY-00:10 | 307.95 | 01-MAY-00:10 | 190.19 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3258.30 | 05-MAY-16:02 | 1921.38 | 09-MAY-06:01 |
| June | 397.10 | 01-JUN-00:10 | 307.95 | 01-JUN-00:10 | 190.19 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3261.26 | 12-JUN-16:01 | 2212.78 | 21-JUN-06:01 |
| July | 397.10 | 01-JUL-00:10 | 307.95 | 01-JUL-00:10 | 190.19 | 01-JUL-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2310.15 | 15-JUL-16:03 | 1794.40 | 07-JUL-06:01 |
| August | 397.10 | 01-AUG-00:10 | 307.95 | 01-AUG-00:10 | 190.19 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2171.64 | 01-AUG-16:02 | 2050.90 | 20-AUG-06:03 |
| September | 397.10 | 01-SEP-00:10 | 307.95 | 01-SEP-00:10 | 190.19 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2159.00 | 04-SEP-16:03 | 1918.44 | 14-SEP-16:03 |
| October | 397.10 | 01-OCT-00:10 | 307.95 | 01-OCT-00:10 | 190.19 | 01-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1604.74 | 04-OCT-16:02 | 2192.25 | 23-OCT-06:01 |
| November | 397.10 | 01-NOV-00:10 | 307.95 | 01-NOV-00:10 | 190.19 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1274.12 | 03-NOV-16:02 | 3178.49 | 25-NOV-07:02 |
| December | 397.10 | 01-DEC-00:10 | 307.95 | 01-DEC-00:10 | 190.19 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1281.28 | 13-DEC-17:02 | 4223.78 | 21-DEC-07:01 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 397.10 | 307.95 | 190.19 | 0.00 | 0.00 | 0.00 | 0.00 | 1274.12 | 1771.97 | |||||
| Maximum of Months | 397.10 | 307.95 | 190.19 | 0.00 | 0.00 | 0.00 | 0.00 | 3261.26 | 4223.78 |
Report: PeakSpaceGainsMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.11 | 04-JAN-13:00 | 16.49 | 07-JAN-05:00 |
| February | 397.10 | 01-FEB-00:10 | 307.95 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.45 | 28-FEB-15:00 | 3.64 | 01-FEB-07:00 |
| March | 397.10 | 01-MAR-00:10 | 307.95 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.13 | 19-MAR-16:00 | 3.02 | 14-MAR-22:00 |
| April | 397.10 | 01-APR-00:10 | 307.95 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.87 | 04-APR-14:00 | 2.23 | 14-APR-15:53 |
| May | 397.10 | 01-MAY-00:10 | 307.95 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.87 | 06-MAY-15:00 | 5.38 | 08-MAY-22:00 |
| June | 397.10 | 01-JUN-00:10 | 307.95 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.28 | 16-JUN-14:40 | 5.18 | 20-JUN-23:00 |
| July | 397.10 | 01-JUL-00:10 | 307.95 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.53 | 01-JUL-13:00 | 4.98 | 03-JUL-13:00 |
| August | 397.10 | 01-AUG-00:10 | 307.95 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.24 | 06-AUG-13:00 | 5.50 | 23-AUG-19:53 |
| September | 397.10 | 01-SEP-00:10 | 307.95 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.01 | 10-SEP-15:00 | 6.67 | 15-SEP-16:53 |
| October | 397.10 | 01-OCT-00:10 | 307.95 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.53 | 29-OCT-13:00 | 2.99 | 30-OCT-17:00 |
| November | 397.10 | 01-NOV-00:10 | 307.95 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.96 | 10-NOV-12:20 | 3.01 | 25-NOV-08:00 |
| December | 397.10 | 01-DEC-00:10 | 307.95 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.86 | 09-DEC-14:00 | 5.80 | 21-DEC-05:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.96 | 2.23 | ||||
| Maximum of Months | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.13 | 16.49 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4722.47 | 23-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.49 |
| February | 4538.28 | 21-FEB-11:02 | 0.00 | 65.78 | 2472.22 | 0.00 | 0.00 | 0.00 | 0.00 | 9.93 | 0.00 |
| March | 4076.90 | 03-MAR-08:62 | 0.00 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 2.18 | 0.00 |
| April | 4093.06 | 14-APR-16:52 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 5.17 | 0.00 |
| May | 3982.59 | 10-MAY-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| June | 4083.86 | 24-JUN-19:52 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.64 |
| July | 4199.20 | 19-JUL-20:22 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.81 |
| August | 3946.85 | 21-AUG-12:02 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 5.81 | 0.00 |
| September | 4129.46 | 14-SEP-16:52 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.01 |
| October | 4271.59 | 09-OCT-19:42 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.09 |
| November | 4399.95 | 24-NOV-22:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.90 |
| December | 4783.27 | 20-DEC-21:32 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.17 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3946.85 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4783.27 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 9.93 | 9.17 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4670.18 | 23-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.26 |
| February | 4435.49 | 24-FEB-09:02 | 356.25 | 65.78 | 2366.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.47 | 0.00 |
| March | 4061.57 | 03-MAR-08:62 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 2.20 | 0.00 |
| April | 4067.73 | 14-APR-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 5.16 | 0.00 |
| May | 4024.95 | 10-MAY-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.65 |
| June | 4217.40 | 25-JUN-19:52 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.31 |
| July | 4403.59 | 19-JUL-19:52 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.16 |
| August | 3984.82 | 23-AUG-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.79 |
| September | 4091.08 | 14-SEP-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.03 |
| October | 4181.35 | 09-OCT-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.16 |
| November | 4313.40 | 25-NOV-20:02 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.08 |
| December | 4694.14 | 20-DEC-22:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.60 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3984.82 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4694.14 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 5.16 | 10.60 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5814.72 | 23-JAN-07:01 | 0.00 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.30 |
| February | 5357.68 | 24-FEB-07:01 | 0.00 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.99 |
| March | 4892.18 | 03-MAR-07:01 | 0.00 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.33 |
| April | 3858.45 | 03-APR-06:01 | 0.00 | 716.20 | 1559.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.75 |
| May | 3959.14 | 30-MAY-10:00 | 451.21 | 447.62 | 544.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 3957.18 | 19-JUN-10:00 | 451.21 | 447.62 | 544.92 | 0.00 | 0.00 | 0.00 | 0.00 | 44.08 | 0.00 |
| July | 4363.11 | 03-JUL-06:01 | 0.00 | 805.72 | 1754.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.69 |
| August | 3796.61 | 28-AUG-09:50 | 451.21 | 447.62 | 544.92 | 0.00 | 0.00 | 0.00 | 0.00 | 24.00 | 0.00 |
| September | 3903.46 | 05-SEP-10:00 | 451.21 | 447.62 | 544.92 | 0.00 | 0.00 | 0.00 | 0.00 | 20.46 | 0.00 |
| October | 4003.54 | 10-OCT-06:01 | 0.00 | 805.72 | 1754.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.37 |
| November | 4763.04 | 24-NOV-07:01 | 0.00 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.38 |
| December | 5200.28 | 21-DEC-07:01 | 0.00 | 626.67 | 1364.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.54 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3796.61 | 0.00 | 447.62 | 544.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5814.72 | 451.21 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 44.08 | 21.54 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4467.26 | 23-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.38 |
| February | 4289.32 | 21-FEB-11:12 | 356.25 | 65.78 | 2472.22 | 0.00 | 0.00 | 0.00 | 0.00 | 10.50 | 0.00 |
| March | 3898.79 | 03-MAR-08:62 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 2.07 | 0.00 |
| April | 3863.81 | 14-APR-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 5.13 | 0.00 |
| May | 3813.97 | 10-MAY-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| June | 3975.12 | 24-JUN-19:52 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.69 |
| July | 4130.57 | 19-JUL-19:52 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.27 |
| August | 3802.05 | 21-AUG-12:02 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 5.71 | 0.00 |
| September | 3907.99 | 14-SEP-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.12 |
| October | 3980.37 | 09-OCT-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.23 |
| November | 4117.93 | 25-NOV-20:02 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.11 |
| December | 4471.29 | 20-DEC-22:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.71 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3802.05 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4471.29 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 10.50 | 10.71 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4005.85 | 23-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.84 |
| February | 3797.57 | 24-FEB-09:02 | 356.25 | 65.78 | 2366.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.16 | 0.00 |
| March | 3492.49 | 03-MAR-08:62 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 1.19 | 0.00 |
| April | 3421.56 | 14-APR-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 3.08 | 0.00 |
| May | 3398.89 | 10-MAY-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.43 |
| June | 3552.52 | 24-JUN-19:52 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.69 |
| July | 3710.49 | 19-JUL-19:52 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.74 |
| August | 3348.55 | 04-AUG-13:52 | 356.25 | 65.78 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.28 |
| September | 3461.09 | 14-SEP-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.76 |
| October | 3531.54 | 09-OCT-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.05 |
| November | 3668.29 | 25-NOV-20:02 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.31 |
| December | 4021.52 | 20-DEC-22:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.59 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3348.55 | 356.25 | 65.78 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4021.52 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 3.08 | 6.59 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4002.19 | 23-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.85 |
| February | 3793.50 | 24-FEB-09:02 | 356.25 | 65.78 | 2366.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.15 | 0.00 |
| March | 3488.56 | 03-MAR-08:62 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 1.19 | 0.00 |
| April | 3417.79 | 14-APR-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 3.08 | 0.00 |
| May | 3394.15 | 10-MAY-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.43 |
| June | 3548.62 | 24-JUN-19:52 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.69 |
| July | 3705.00 | 19-JUL-19:52 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.74 |
| August | 3345.50 | 04-AUG-13:52 | 356.25 | 65.78 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.28 |
| September | 3457.52 | 14-SEP-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.76 |
| October | 3527.70 | 09-OCT-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.05 |
| November | 3664.68 | 25-NOV-20:02 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.31 |
| December | 4016.84 | 20-DEC-22:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.59 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3345.50 | 356.25 | 65.78 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4016.84 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 3.08 | 6.59 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4065.83 | 23-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.01 |
| February | 3884.43 | 21-FEB-11:02 | 0.00 | 65.78 | 2472.22 | 0.00 | 0.00 | 0.00 | 0.00 | 5.89 | 0.00 |
| March | 3510.08 | 03-MAR-08:62 | 0.00 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 1.18 | 0.00 |
| April | 3439.31 | 14-APR-16:52 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 3.11 | 0.00 |
| May | 3341.21 | 10-MAY-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.44 |
| June | 3475.74 | 24-JUN-19:52 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.69 |
| July | 3524.16 | 19-JUL-20:22 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.94 |
| August | 3354.28 | 21-AUG-12:02 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 3.35 | 0.00 |
| September | 3499.92 | 14-SEP-16:52 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.73 |
| October | 3631.73 | 09-OCT-19:42 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.99 |
| November | 3789.87 | 24-NOV-22:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.41 |
| December | 4130.00 | 20-DEC-21:32 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.82 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3341.21 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4130.00 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 5.89 | 5.82 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4149.21 | 23-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.15 |
| February | 4056.60 | 21-FEB-10:42 | 0.00 | 65.78 | 2436.90 | 0.00 | 0.00 | 0.00 | 0.00 | 2.82 | 0.00 |
| March | 3579.79 | 03-MAR-08:62 | 0.00 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 1.19 | 0.00 |
| April | 3507.96 | 14-APR-16:52 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 3.09 | 0.00 |
| May | 3420.91 | 10-MAY-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.43 |
| June | 3569.54 | 24-JUN-19:52 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.70 |
| July | 3595.45 | 19-JUL-20:22 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.92 |
| August | 3436.84 | 21-AUG-12:02 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 3.36 | 0.00 |
| September | 3565.84 | 14-SEP-16:52 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.74 |
| October | 3729.47 | 09-OCT-19:42 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.98 |
| November | 3846.84 | 24-NOV-22:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.33 |
| December | 4173.00 | 20-DEC-21:32 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.76 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3420.91 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4173.00 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 3.36 | 5.76 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5017.57 | 23-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.48 |
| February | 4861.39 | 21-FEB-11:02 | 0.00 | 65.78 | 2472.22 | 0.00 | 0.00 | 0.00 | 0.00 | 14.37 | 0.00 |
| March | 4292.85 | 03-MAR-08:62 | 0.00 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 3.53 | 0.00 |
| April | 4349.52 | 14-APR-16:52 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 7.58 | 0.00 |
| May | 4224.53 | 10-MAY-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 |
| June | 4307.02 | 24-JUN-19:52 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.70 |
| July | 4434.12 | 19-JUL-20:22 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.13 |
| August | 4133.87 | 21-AUG-12:02 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 8.45 | 0.00 |
| September | 4327.81 | 14-SEP-16:52 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.13 |
| October | 4542.04 | 09-OCT-19:42 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.34 |
| November | 4701.65 | 24-NOV-22:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.10 |
| December | 5153.56 | 20-DEC-21:32 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.40 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 4133.87 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5153.56 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 14.37 | 13.40 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4974.24 | 23-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.17 |
| February | 4722.96 | 24-FEB-09:02 | 356.25 | 65.78 | 2366.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.93 | 0.00 |
| March | 4265.79 | 03-MAR-08:62 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 3.95 | 0.00 |
| April | 4333.60 | 14-APR-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 7.52 | 0.00 |
| May | 4277.08 | 10-MAY-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.98 |
| June | 4447.21 | 25-JUN-19:52 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.27 |
| July | 4669.31 | 19-JUL-19:52 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.97 |
| August | 4155.81 | 23-AUG-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.00 |
| September | 4297.51 | 14-SEP-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.21 |
| October | 4440.49 | 09-OCT-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.46 |
| November | 4602.68 | 25-NOV-20:02 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.95 |
| December | 4965.92 | 20-DEC-22:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.95 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 4155.81 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4974.24 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 7.52 | 14.95 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4774.65 | 23-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.64 |
| February | 5000.18 | 21-FEB-10:42 | 0.00 | 65.78 | 2436.90 | 0.00 | 0.00 | 0.00 | 0.00 | 6.26 | 0.00 |
| March | 4119.57 | 03-MAR-08:62 | 0.00 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 3.04 | 0.00 |
| April | 4084.26 | 14-APR-16:52 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 7.63 | 0.00 |
| May | 3943.96 | 10-MAY-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.02 |
| June | 4092.36 | 24-JUN-19:52 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.80 |
| July | 4102.40 | 19-JUL-20:22 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.37 |
| August | 4003.89 | 21-AUG-12:02 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 8.30 | 0.00 |
| September | 4116.76 | 14-SEP-16:52 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.29 |
| October | 4298.49 | 09-OCT-19:42 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.46 |
| November | 4458.89 | 25-NOV-19:52 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.25 |
| December | 4888.39 | 20-DEC-21:32 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.64 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3943.96 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5000.18 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 8.30 | 13.64 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4738.87 | 23-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.38 |
| February | 4579.00 | 21-FEB-11:12 | 356.25 | 65.78 | 2472.22 | 0.00 | 0.00 | 0.00 | 0.00 | 15.21 | 0.00 |
| March | 4108.92 | 03-MAR-08:62 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 3.06 | 0.00 |
| April | 4071.51 | 14-APR-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 7.54 | 0.00 |
| May | 4030.95 | 10-MAY-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.01 |
| June | 4178.22 | 24-JUN-19:52 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.79 |
| July | 4345.64 | 19-JUL-19:52 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.19 |
| August | 3998.48 | 21-AUG-12:02 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 8.29 | 0.00 |
| September | 4087.32 | 14-SEP-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.37 |
| October | 4187.69 | 09-OCT-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.60 |
| November | 4373.92 | 25-NOV-20:02 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 |
| December | 4703.26 | 20-DEC-22:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3998.48 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4738.87 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 15.21 | 15.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4255.57 | 23-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.03 |
| February | 4023.56 | 24-FEB-09:02 | 356.25 | 65.78 | 2366.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.58 | 0.00 |
| March | 3660.01 | 03-MAR-08:62 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 2.36 | 0.00 |
| April | 3595.38 | 14-APR-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 4.65 | 0.00 |
| May | 3557.21 | 10-MAY-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.63 |
| June | 3744.55 | 24-JUN-19:52 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.35 |
| July | 3901.14 | 19-JUL-19:52 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.17 |
| August | 3493.80 | 21-AUG-12:02 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 4.90 | 0.00 |
| September | 3605.03 | 14-SEP-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.59 |
| October | 3729.53 | 09-OCT-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.89 |
| November | 3893.54 | 25-NOV-20:02 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.86 |
| December | 4234.39 | 20-DEC-22:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.01 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3493.80 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4255.57 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 4.90 | 9.01 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4251.57 | 23-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.03 |
| February | 4021.22 | 24-FEB-09:02 | 356.25 | 65.78 | 2366.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.56 | 0.00 |
| March | 3656.03 | 03-MAR-08:62 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 2.35 | 0.00 |
| April | 3590.78 | 14-APR-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 4.65 | 0.00 |
| May | 3551.45 | 10-MAY-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.63 |
| June | 3740.22 | 24-JUN-19:52 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.35 |
| July | 3894.66 | 19-JUL-19:52 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.17 |
| August | 3491.30 | 21-AUG-12:02 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 4.89 | 0.00 |
| September | 3601.53 | 14-SEP-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| October | 3725.12 | 09-OCT-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.89 |
| November | 3889.66 | 25-NOV-20:02 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.86 |
| December | 4229.05 | 20-DEC-22:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.01 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3491.30 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4251.57 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 4.89 | 9.01 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4308.90 | 23-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.27 |
| February | 4142.06 | 21-FEB-11:02 | 0.00 | 65.78 | 2472.22 | 0.00 | 0.00 | 0.00 | 0.00 | 8.51 | 0.00 |
| March | 3686.12 | 03-MAR-08:62 | 0.00 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 2.09 | 0.00 |
| April | 3603.55 | 14-APR-16:52 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 4.72 | 0.00 |
| May | 3485.35 | 10-MAY-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.63 |
| June | 3644.84 | 24-JUN-19:52 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.24 |
| July | 3583.65 | 19-JUL-20:22 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.95 |
| August | 3499.94 | 21-AUG-12:02 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 4.93 | 0.00 |
| September | 3636.81 | 14-SEP-16:52 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.52 |
| October | 3834.90 | 09-OCT-19:42 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.81 |
| November | 4030.74 | 24-NOV-22:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.36 |
| December | 4435.97 | 20-DEC-21:32 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.44 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3485.35 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4435.97 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 8.51 | 8.44 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4304.50 | 23-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.27 |
| February | 4138.99 | 21-FEB-11:02 | 0.00 | 65.78 | 2472.22 | 0.00 | 0.00 | 0.00 | 0.00 | 8.50 | 0.00 |
| March | 3682.17 | 03-MAR-08:62 | 0.00 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 2.08 | 0.00 |
| April | 3599.02 | 14-APR-16:52 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 4.73 | 0.00 |
| May | 3479.12 | 10-MAY-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.63 |
| June | 3640.78 | 24-JUN-19:52 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.24 |
| July | 3576.61 | 19-JUL-20:22 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.93 |
| August | 3497.85 | 21-AUG-12:02 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 4.92 | 0.00 |
| September | 3633.34 | 14-SEP-16:52 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.52 |
| October | 3830.38 | 09-OCT-19:42 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.81 |
| November | 4025.84 | 24-NOV-22:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.36 |
| December | 4430.54 | 20-DEC-21:32 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.45 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3479.12 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4430.54 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 8.50 | 8.45 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5309.27 | 23-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.59 |
| February | 5528.45 | 21-FEB-10:42 | 0.00 | 65.78 | 2436.90 | 0.00 | 0.00 | 0.00 | 0.00 | 7.30 | 0.00 |
| March | 4454.62 | 03-MAR-08:62 | 0.00 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 4.19 | 0.00 |
| April | 4594.88 | 14-APR-16:52 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 9.88 | 0.00 |
| May | 4553.68 | 10-MAY-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.24 |
| June | 4809.13 | 25-JUN-19:52 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.82 |
| July | 4781.49 | 19-JUL-20:22 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.91 |
| August | 4541.89 | 21-AUG-12:02 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 10.91 | 0.00 |
| September | 4569.86 | 14-SEP-16:52 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.77 |
| October | 4873.64 | 09-OCT-19:42 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.83 |
| November | 5027.25 | 25-NOV-19:52 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.24 |
| December | 5452.45 | 20-DEC-21:32 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.27 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 4454.62 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5528.45 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 10.91 | 17.27 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5307.42 | 23-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.22 |
| February | 5007.60 | 21-FEB-11:12 | 356.25 | 65.78 | 2472.22 | 0.00 | 0.00 | 0.00 | 0.00 | 20.08 | 0.00 |
| March | 4467.09 | 03-MAR-08:62 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 4.30 | 0.00 |
| April | 4596.34 | 14-APR-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 9.84 | 0.00 |
| May | 4632.77 | 10-MAY-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.23 |
| June | 4823.87 | 25-JUN-19:52 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.40 |
| July | 5045.30 | 19-JUL-19:52 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.47 |
| August | 4580.46 | 21-AUG-12:02 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 10.91 | 0.00 |
| September | 4567.62 | 14-SEP-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.81 |
| October | 4798.57 | 09-OCT-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.92 |
| November | 4935.05 | 25-NOV-20:02 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.89 |
| December | 5362.00 | 20-DEC-22:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.82 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 4467.09 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5362.00 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 20.08 | 19.82 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5154.37 | 31-JAN-10:32 | 0.00 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 5.75 | 0.00 |
| February | 5524.24 | 21-FEB-10:42 | 0.00 | 65.78 | 2436.90 | 0.00 | 0.00 | 0.00 | 0.00 | 4.24 | 0.00 |
| March | 4203.98 | 03-MAR-08:62 | 0.00 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 3.80 | 0.00 |
| April | 4218.66 | 14-APR-16:52 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 9.80 | 0.00 |
| May | 4178.76 | 10-MAY-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.29 |
| June | 4292.23 | 30-JUN-13:52 | 0.00 | 65.78 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 3.18 | 0.00 |
| July | 4491.46 | 03-JUL-14:02 | 0.00 | 95.95 | 2001.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.40 |
| August | 4322.77 | 21-AUG-12:02 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 10.56 | 0.00 |
| September | 4253.53 | 14-SEP-16:52 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.05 |
| October | 4510.98 | 09-OCT-19:42 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.04 |
| November | 4675.83 | 25-NOV-19:52 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.35 |
| December | 5066.80 | 20-DEC-21:32 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.72 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 4178.76 | 0.00 | 54.82 | 2001.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5524.24 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 10.56 | 17.72 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4951.07 | 23-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.52 |
| February | 5212.16 | 21-FEB-10:52 | 296.88 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 12.20 | 0.00 |
| March | 4216.50 | 03-MAR-08:62 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 3.88 | 0.00 |
| April | 4217.69 | 14-APR-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 9.76 | 0.00 |
| May | 4280.69 | 10-MAY-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.27 |
| June | 4383.58 | 25-JUN-19:52 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.49 |
| July | 4620.98 | 03-JUL-14:02 | 296.88 | 95.95 | 2001.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.91 |
| August | 4354.01 | 21-AUG-12:02 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 10.55 | 0.00 |
| September | 4250.43 | 14-SEP-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.09 |
| October | 4434.85 | 09-OCT-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.16 |
| November | 4589.03 | 25-NOV-20:02 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.98 |
| December | 4908.87 | 20-DEC-22:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.25 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 4216.50 | 296.88 | 54.82 | 2001.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5212.16 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 12.20 | 20.25 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4614.84 | 23-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.02 |
| February | 4328.79 | 24-FEB-09:02 | 356.25 | 65.78 | 2366.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 | 0.00 |
| March | 3919.83 | 03-MAR-08:62 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 2.30 | 0.00 |
| April | 3900.25 | 14-APR-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 5.85 | 0.00 |
| May | 3961.66 | 10-MAY-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.80 |
| June | 4093.15 | 25-JUN-19:52 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.74 |
| July | 4303.57 | 19-JUL-19:52 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.90 |
| August | 3912.44 | 21-AUG-12:02 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 6.32 | 0.00 |
| September | 3935.49 | 14-SEP-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.40 |
| October | 4115.44 | 09-OCT-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.82 |
| November | 4257.92 | 25-NOV-20:02 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.45 |
| December | 4596.22 | 20-DEC-22:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.41 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3900.25 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4614.84 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 6.32 | 12.41 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4601.37 | 23-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.03 |
| February | 4317.51 | 24-FEB-09:02 | 356.25 | 65.78 | 2366.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.34 | 0.00 |
| March | 3908.04 | 03-MAR-08:62 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 2.30 | 0.00 |
| April | 3887.04 | 14-APR-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 5.85 | 0.00 |
| May | 3947.66 | 10-MAY-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.80 |
| June | 4077.05 | 25-JUN-19:52 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.74 |
| July | 4286.48 | 19-JUL-19:52 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.91 |
| August | 3903.61 | 21-AUG-12:02 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 6.31 | 0.00 |
| September | 3924.37 | 14-SEP-16:52 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.40 |
| October | 4101.99 | 09-OCT-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.83 |
| November | 4245.22 | 25-NOV-20:02 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.45 |
| December | 4581.29 | 20-DEC-22:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.42 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3887.04 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4601.37 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 6.31 | 12.42 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4618.63 | 23-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.23 |
| February | 4737.01 | 21-FEB-10:42 | 0.00 | 65.78 | 2436.90 | 0.00 | 0.00 | 0.00 | 0.00 | 4.62 | 0.00 |
| March | 3909.72 | 03-MAR-08:62 | 0.00 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 2.25 | 0.00 |
| April | 3896.27 | 14-APR-16:52 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 5.89 | 0.00 |
| May | 3885.11 | 10-MAY-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.81 |
| June | 3955.73 | 24-JUN-19:52 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.19 |
| July | 4023.73 | 19-JUL-20:22 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.36 |
| August | 3878.25 | 21-AUG-12:02 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 6.34 | 0.00 |
| September | 3940.17 | 14-SEP-16:52 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.35 |
| October | 4181.76 | 09-OCT-19:42 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.74 |
| November | 4325.36 | 25-NOV-19:52 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.68 |
| December | 4746.16 | 20-DEC-21:32 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.94 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3878.25 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4746.16 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 6.34 | 10.94 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4609.25 | 23-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.23 |
| February | 4738.61 | 21-FEB-10:42 | 0.00 | 65.78 | 2436.90 | 0.00 | 0.00 | 0.00 | 0.00 | 4.55 | 0.00 |
| March | 3902.90 | 03-MAR-08:62 | 0.00 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 2.24 | 0.00 |
| April | 3885.69 | 14-APR-16:52 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 5.89 | 0.00 |
| May | 3874.31 | 10-MAY-21:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.81 |
| June | 3946.55 | 24-JUN-19:52 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.19 |
| July | 4010.16 | 19-JUL-20:22 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.36 |
| August | 3873.13 | 21-AUG-12:02 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 6.33 | 0.00 |
| September | 3932.43 | 14-SEP-16:52 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.36 |
| October | 4171.65 | 09-OCT-19:42 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.74 |
| November | 4316.18 | 25-NOV-19:52 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.68 |
| December | 4735.74 | 20-DEC-21:32 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.95 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3873.13 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4738.61 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 6.33 | 10.95 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.55 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.16 | 0.00 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.23 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.05 | 0.00 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.87 | 0.00 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.44 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.32 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.39 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.32 | 0.00 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.02 | 0.00 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.25 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.80 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.87 | 1.44 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.73 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.59 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.97 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.20 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 | 0.00 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.30 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.76 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.12 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.45 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.26 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.42 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.73 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 | 1.30 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.15 | 0.00 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.13 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.71 | 0.00 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.41 | 0.00 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.01 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.25 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.27 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.34 | 0.00 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 | 0.00 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.19 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.41 | 1.01 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
| January | 0.958746E+11 | 54959.97 | 22-JAN-11:20 | 0.262643E+11 | 18960.66 | 17-JAN-07:49 |
| February | 0.894754E+11 | 54019.00 | 06-FEB-17:00 | 0.235729E+11 | 18943.44 | 02-FEB-07:30 |
| March | 0.101577E+12 | 57458.77 | 19-MAR-16:10 | 0.257166E+11 | 18840.84 | 07-MAR-07:30 |
| April | 0.101956E+12 | 57605.87 | 02-APR-16:10 | 0.243819E+11 | 18213.79 | 01-APR-06:30 |
| May | 0.108266E+12 | 60740.54 | 06-MAY-16:10 | 0.246852E+11 | 17489.30 | 01-MAY-06:19 |
| June | 0.106122E+12 | 61373.15 | 13-JUN-16:10 | 0.235367E+11 | 17384.59 | 01-JUN-06:40 |
| July | 0.998108E+11 | 55335.21 | 15-JUL-16:10 | 0.242167E+11 | 17328.76 | 31-JUL-06:00 |
| August | 0.102025E+12 | 56667.15 | 19-AUG-19:00 | 0.243776E+11 | 17400.62 | 31-AUG-06:19 |
| September | 0.981237E+11 | 56468.32 | 15-SEP-18:49 | 0.239707E+11 | 17513.00 | 29-SEP-06:40 |
| October | 0.985589E+11 | 59438.14 | 30-OCT-17:00 | 0.252948E+11 | 18437.00 | 31-OCT-06:00 |
| November | 0.946888E+11 | 53421.96 | 04-NOV-16:10 | 0.249677E+11 | 18877.08 | 30-NOV-07:00 |
| December | 0.951718E+11 | 53317.78 | 01-DEC-08:50 | 0.261577E+11 | 18950.23 | 27-DEC-07:19 |
| Annual Sum or Average | 0.119165E+13 | 0.297143E+12 | ||||
| Minimum of Months | 0.894754E+11 | 53317.78 | 0.235367E+11 | 17328.76 | ||
| Maximum of Months | 0.108266E+12 | 61373.15 | 0.262643E+11 | 18960.66 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [J] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [J] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
| January | 0.618562E+10 | 0.294480E+10 | 0.385428E+11 | 0.00 | 0.133058E+11 | 38818862.27 | 0.00 | 0.348567E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.559770E+10 | 0.261830E+10 | 0.348258E+11 | 0.00 | 0.125197E+11 | 35062198.18 | 0.00 | 0.338788E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.621989E+10 | 0.280992E+10 | 0.385844E+11 | 0.00 | 0.142945E+11 | 38818862.27 | 0.00 | 0.396300E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.599345E+10 | 0.265486E+10 | 0.373085E+11 | 0.00 | 0.144877E+11 | 37566640.91 | 0.00 | 0.414743E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.620847E+10 | 0.269646E+10 | 0.385705E+11 | 0.00 | 0.154905E+11 | 38818862.27 | 0.00 | 0.452612E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.601630E+10 | 0.257922E+10 | 0.373361E+11 | 0.00 | 0.152572E+11 | 37566640.91 | 0.00 | 0.448957E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.618562E+10 | 0.268638E+10 | 0.385428E+11 | 0.00 | 0.141107E+11 | 38818862.27 | 0.00 | 0.382464E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.621989E+10 | 0.272041E+10 | 0.385844E+11 | 0.00 | 0.144209E+11 | 38818862.27 | 0.00 | 0.400404E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.599345E+10 | 0.270024E+10 | 0.373085E+11 | 0.00 | 0.138603E+11 | 37566640.91 | 0.00 | 0.382237E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.619704E+10 | 0.286286E+10 | 0.385567E+11 | 0.00 | 0.138230E+11 | 38818862.27 | 0.00 | 0.370804E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.599345E+10 | 0.282631E+10 | 0.373085E+11 | 0.00 | 0.132470E+11 | 37566640.91 | 0.00 | 0.352760E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.618562E+10 | 0.296371E+10 | 0.385428E+11 | 0.00 | 0.131901E+11 | 38818862.27 | 0.00 | 0.342507E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.729965E+11 | 0.330635E+11 | 0.454012E+12 | 0.00 | 0.168007E+12 | 0.457061E+09 | 0.00 | 0.463114E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.559770E+10 | 0.257922E+10 | 0.348258E+11 | 0.00 | 0.125197E+11 | 35062198.18 | 0.00 | 0.338788E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.621989E+10 | 0.296371E+10 | 0.385844E+11 | 0.00 | 0.154905E+11 | 38818862.27 | 0.00 | 0.452612E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [J] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.262643E+11 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.235729E+11 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.257166E+11 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.243819E+11 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.246852E+11 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.235367E+11 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.242167E+11 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.243776E+11 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.239707E+11 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.252948E+11 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.249677E+11 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.261577E+11 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.297143E+12 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.235367E+11 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.262643E+11 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY {Maximum} [W] | PUMPS:ELECTRICITY {TIMESTAMP} | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
| January | 4040.47 | 01-JAN-19:10 | 2101.03 | 01-JAN-00:10 | 22246.15 | 03-JAN-17:10 | 0.00 | 8579.35 | 22-JAN-11:20 | 14.49 | 01-JAN-06:00 | 0.00 | 01-JAN-00:10 |
| February | 4040.47 | 01-FEB-19:10 | 2101.03 | 01-FEB-00:10 | 22246.15 | 01-FEB-17:10 | 0.00 | 7941.76 | 23-FEB-11:09 | 14.49 | 01-FEB-06:19 | 0.00 | 01-FEB-00:10 |
| March | 4040.47 | 01-MAR-19:10 | 2101.03 | 01-MAR-00:10 | 22246.15 | 01-MAR-17:10 | 0.00 | 7504.01 | 19-MAR-16:10 | 14.49 | 01-MAR-07:30 | 0.00 | 01-MAR-00:10 |
| April | 4040.47 | 01-APR-18:10 | 2101.03 | 01-APR-00:10 | 22246.15 | 03-APR-16:10 | 0.00 | 7532.51 | 02-APR-16:10 | 14.49 | 01-APR-17:10 | 0.00 | 01-APR-00:10 |
| May | 4040.47 | 01-MAY-18:10 | 2101.03 | 01-MAY-00:10 | 22246.15 | 01-MAY-16:10 | 0.00 | 8066.33 | 06-MAY-16:10 | 14.49 | 01-MAY-06:30 | 0.00 | 01-MAY-00:10 |
| June | 4040.47 | 01-JUN-18:10 | 2101.03 | 01-JUN-00:10 | 22246.15 | 01-JUN-16:10 | 0.00 | 8152.50 | 13-JUN-16:10 | 14.49 | 01-JUN-06:30 | 0.00 | 01-JUN-00:10 |
| July | 4040.47 | 01-JUL-18:10 | 2101.03 | 01-JUL-00:10 | 22246.15 | 03-JUL-16:10 | 0.00 | 8084.45 | 03-JUL-14:30 | 14.49 | 03-JUL-13:30 | 0.00 | 01-JUL-00:10 |
| August | 4040.47 | 01-AUG-18:10 | 2101.03 | 01-AUG-00:10 | 22246.15 | 01-AUG-16:10 | 0.00 | 8301.45 | 20-AUG-13:20 | 14.49 | 01-AUG-16:19 | 0.00 | 01-AUG-00:10 |
| September | 4040.47 | 01-SEP-18:10 | 2101.03 | 01-SEP-00:10 | 22246.15 | 01-SEP-16:10 | 0.00 | 8034.50 | 15-SEP-20:00 | 14.49 | 01-SEP-17:19 | 0.00 | 01-SEP-00:10 |
| October | 4040.47 | 01-OCT-18:10 | 2101.03 | 01-OCT-00:10 | 22246.15 | 02-OCT-16:10 | 0.00 | 8288.37 | 30-OCT-19:40 | 14.49 | 01-OCT-06:10 | 0.00 | 01-OCT-00:10 |
| November | 4040.47 | 01-NOV-18:10 | 2101.03 | 01-NOV-00:10 | 22246.15 | 01-NOV-16:10 | 0.00 | 7423.38 | 19-NOV-08:20 | 14.49 | 02-NOV-07:10 | 0.00 | 01-NOV-00:10 |
| December | 4040.47 | 01-DEC-19:10 | 2101.03 | 01-DEC-00:10 | 22246.15 | 01-DEC-17:10 | 0.00 | 8159.41 | 01-DEC-08:50 | 14.49 | 01-DEC-08:09 | 0.00 | 01-DEC-00:10 |
| Annual Sum or Average | 0.00 | ||||||||||||
| Minimum of Months | 4040.47 | 2101.03 | 22246.15 | 0.00 | 7423.38 | 14.49 | 0.00 | ||||||
| Maximum of Months | 4040.47 | 2101.03 | 22246.15 | 0.00 | 8579.35 | 14.49 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY {Maximum} [W] | HEATRECOVERY:ELECTRICITY {TIMESTAMP} | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
| January | 28021.35 | 22-JAN-11:20 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 26846.56 | 23-FEB-11:09 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 24739.67 | 19-MAR-16:10 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 24858.26 | 02-APR-16:10 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 27875.22 | 06-MAY-15:09 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 29029.57 | 13-JUN-15:09 | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 25626.21 | 03-JUL-14:30 | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 26324.01 | 21-AUG-12:09 | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 24403.65 | 18-SEP-08:39 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 24881.82 | 30-OCT-19:40 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 23335.93 | 06-NOV-07:00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 26562.61 | 01-DEC-08:50 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 23335.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Maximum of Months | 29029.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
| January | 54959.97 | 22-JAN-11:20 | 1661.16 | 16683.62 | 0.00 | 0.00 | 8579.35 | 14.49 | 0.00 | 28021.35 | 0.00 |
| February | 54019.00 | 06-FEB-17:00 | 3020.75 | 22246.15 | 2101.03 | 0.00 | 6481.37 | 14.49 | 0.00 | 20155.21 | 0.00 |
| March | 57458.77 | 19-MAR-16:10 | 3020.75 | 22179.86 | 0.00 | 0.00 | 7504.01 | 14.49 | 0.00 | 24739.67 | 0.00 |
| April | 57605.87 | 02-APR-16:10 | 3020.75 | 22179.86 | 0.00 | 0.00 | 7532.51 | 14.49 | 0.00 | 24858.26 | 0.00 |
| May | 60740.54 | 06-MAY-16:10 | 3020.75 | 22179.86 | 0.00 | 0.00 | 8066.33 | 14.49 | 0.00 | 27459.12 | 0.00 |
| June | 61373.15 | 13-JUN-16:10 | 3020.75 | 22246.15 | 0.00 | 0.00 | 8152.50 | 14.49 | 0.00 | 27939.27 | 0.00 |
| July | 55335.21 | 15-JUL-16:10 | 3020.75 | 22179.86 | 0.00 | 0.00 | 7152.42 | 14.49 | 0.00 | 22967.69 | 0.00 |
| August | 56667.15 | 19-AUG-19:00 | 4040.47 | 17993.99 | 2101.03 | 0.00 | 8143.93 | 14.49 | 0.00 | 24373.25 | 0.00 |
| September | 56468.32 | 15-SEP-18:49 | 4040.47 | 18723.88 | 2101.03 | 0.00 | 7946.57 | 14.49 | 0.00 | 23641.88 | 0.00 |
| October | 59438.14 | 30-OCT-17:00 | 3615.61 | 20849.51 | 2101.03 | 0.00 | 8223.07 | 14.49 | 0.00 | 24634.43 | 0.00 |
| November | 53421.96 | 04-NOV-16:10 | 3020.75 | 22179.86 | 0.00 | 0.00 | 6936.15 | 14.49 | 0.00 | 21270.72 | 0.00 |
| December | 53317.78 | 01-DEC-08:50 | 2189.27 | 16392.00 | 0.00 | 0.00 | 8159.41 | 14.49 | 0.00 | 26562.61 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | |||||||||
| Minimum of Months | 53317.78 | 1661.16 | 16392.00 | 0.00 | 0.00 | 6481.37 | 14.49 | 0.00 | 20155.21 | 0.00 | |
| Maximum of Months | 61373.15 | 4040.47 | 22246.15 | 2101.03 | 0.00 | 8579.35 | 14.49 | 0.00 | 28021.35 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS {Maximum} [W] | WATERSYSTEMS:NATURALGAS {TIMESTAMP} | COGENERATION:NATURALGAS [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 18960.66 | 17-JAN-07:49 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 18943.44 | 02-FEB-07:30 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 18840.84 | 07-MAR-07:30 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 18213.79 | 01-APR-06:30 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 17489.30 | 01-MAY-06:19 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 17384.59 | 01-JUN-06:40 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 17328.76 | 31-JUL-06:00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 17400.62 | 31-AUG-06:19 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 17513.00 | 29-SEP-06:40 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 18437.00 | 31-OCT-06:00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 18877.08 | 30-NOV-07:00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 18950.23 | 27-DEC-07:19 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 17328.76 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 18960.66 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 4.17 | 25.30 | 0.00 | 25.30 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 4.33 | 25.28 | 0.00 | 25.28 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 5.67 | 25.44 | 0.00 | 25.44 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 5.67 | 25.76 | 0.00 | 25.76 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 9.67 | 25.63 | 0.00 | 25.63 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 10.00 | 25.63 | 0.00 | 25.63 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 5.50 | 25.51 | 0.00 | 25.51 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 8.33 | 25.56 | 0.00 | 25.56 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 5.67 | 25.68 | 0.00 | 25.68 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 5.83 | 25.51 | 0.00 | 25.51 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 5.00 | 25.55 | 0.00 | 25.55 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 4.17 | 25.25 | 0.00 | 25.25 |
| Annual Sum or Average | 0.00 | 0.00 | 74.00 | 25.54 | 0.00 | 25.54 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 4.17 | 25.25 | 0.00 | 25.25 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 10.00 | 25.76 | 0.00 | 25.76 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 34.83 | 25.58 | 533.00 | 24.26 | 34.83 | 24.33 |
| February | 12.00 | 25.77 | 473.00 | 24.18 | 12.00 | 24.22 |
| March | 4.17 | 25.49 | 506.00 | 24.03 | 4.17 | 24.04 |
| April | 2.50 | 24.00 | 510.00 | 24.00 | 2.50 | 24.00 |
| May | 186.83 | 24.03 | 515.00 | 24.02 | 186.83 | 24.02 |
| June | 128.33 | 24.08 | 492.00 | 24.04 | 128.33 | 24.04 |
| July | 8.67 | 25.28 | 533.00 | 24.05 | 8.67 | 24.07 |
| August | 132.67 | 24.12 | 506.00 | 24.05 | 132.67 | 24.06 |
| September | 34.17 | 24.40 | 510.00 | 24.05 | 34.17 | 24.07 |
| October | 31.00 | 24.53 | 524.00 | 24.06 | 31.00 | 24.09 |
| November | 20.00 | 25.50 | 510.00 | 24.17 | 20.00 | 24.22 |
| December | 43.17 | 25.61 | 533.00 | 24.30 | 43.17 | 24.39 |
| Annual Sum or Average | 638.33 | 24.40 | 6145.00 | 24.10 | 638.33 | 24.12 |
| Minimum of Months | 2.50 | 24.00 | 473.00 | 24.00 | 2.50 | 24.00 |
| Maximum of Months | 186.83 | 25.77 | 533.00 | 24.30 | 186.83 | 24.39 |
Report: ComfortReportSimple55Monthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 59.00 | 25.42 | 744.00 | 24.25 | 59.00 | 24.33 |
| February | 23.33 | 25.53 | 672.00 | 24.17 | 23.33 | 24.21 |
| March | 5.83 | 25.21 | 744.00 | 24.02 | 5.83 | 24.03 |
| April | 2.50 | 24.00 | 720.00 | 24.00 | 2.50 | 24.00 |
| May | 147.50 | 24.03 | 744.00 | 24.01 | 147.50 | 24.02 |
| June | 46.00 | 24.20 | 720.00 | 24.03 | 46.00 | 24.04 |
| July | 7.33 | 25.42 | 744.00 | 24.04 | 7.33 | 24.05 |
| August | 110.17 | 24.17 | 744.00 | 24.04 | 110.17 | 24.06 |
| September | 36.33 | 24.48 | 720.00 | 24.05 | 36.33 | 24.07 |
| October | 71.00 | 24.34 | 744.00 | 24.06 | 71.00 | 24.09 |
| November | 36.33 | 25.12 | 720.00 | 24.14 | 36.33 | 24.18 |
| December | 73.83 | 25.27 | 744.00 | 24.26 | 73.83 | 24.34 |
| Annual Sum or Average | 619.17 | 24.56 | 8760.00 | 24.09 | 619.17 | 24.12 |
| Minimum of Months | 2.50 | 24.00 | 672.00 | 24.00 | 2.50 | 24.00 |
| Maximum of Months | 147.50 | 25.53 | 744.00 | 24.26 | 147.50 | 24.34 |
Report: ComfortReportSimple55Monthly
For: OFFICE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.50 | 24.00 | 140.00 | 24.00 | 0.50 | 24.00 |
| February | 0.17 | 24.00 | 133.00 | 24.00 | 0.17 | 24.00 |
| March | 1.00 | 24.00 | 161.00 | 24.00 | 1.00 | 24.00 |
| April | 1.33 | 24.00 | 140.00 | 24.00 | 1.33 | 24.00 |
| May | 6.17 | 24.01 | 154.00 | 24.00 | 6.17 | 24.00 |
| June | 6.17 | 24.00 | 154.00 | 24.00 | 6.17 | 24.00 |
| July | 2.33 | 24.00 | 140.00 | 24.00 | 2.33 | 24.00 |
| August | 6.50 | 24.00 | 161.00 | 24.00 | 6.50 | 24.00 |
| September | 3.67 | 24.00 | 140.00 | 24.00 | 3.67 | 24.00 |
| October | 4.17 | 24.00 | 147.00 | 24.00 | 4.17 | 24.00 |
| November | 2.17 | 24.00 | 140.00 | 24.00 | 2.17 | 24.00 |
| December | 0.33 | 24.00 | 140.00 | 24.00 | 0.33 | 24.00 |
| Annual Sum or Average | 34.50 | 24.00 | 1750.00 | 24.00 | 34.50 | 24.00 |
| Minimum of Months | 0.17 | 24.00 | 133.00 | 24.00 | 0.17 | 24.00 |
| Maximum of Months | 6.50 | 24.01 | 161.00 | 24.00 | 6.50 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 55.50 | 25.63 | 744.00 | 24.27 | 55.50 | 24.36 |
| February | 21.50 | 25.72 | 672.00 | 24.18 | 21.50 | 24.23 |
| March | 5.67 | 25.29 | 744.00 | 24.02 | 5.67 | 24.03 |
| April | 3.33 | 24.10 | 720.00 | 24.00 | 3.33 | 24.00 |
| May | 150.83 | 24.03 | 744.00 | 24.01 | 150.83 | 24.01 |
| June | 46.50 | 24.22 | 720.00 | 24.03 | 46.50 | 24.04 |
| July | 7.67 | 25.48 | 744.00 | 24.04 | 7.67 | 24.05 |
| August | 103.00 | 24.18 | 744.00 | 24.04 | 103.00 | 24.06 |
| September | 38.33 | 24.45 | 720.00 | 24.05 | 38.33 | 24.07 |
| October | 82.17 | 24.29 | 744.00 | 24.06 | 82.17 | 24.08 |
| November | 30.33 | 25.34 | 720.00 | 24.14 | 30.33 | 24.19 |
| December | 70.33 | 25.45 | 744.00 | 24.28 | 70.33 | 24.37 |
| Annual Sum or Average | 615.17 | 24.59 | 8760.00 | 24.09 | 615.17 | 24.13 |
| Minimum of Months | 3.33 | 24.03 | 672.00 | 24.00 | 3.33 | 24.00 |
| Maximum of Months | 150.83 | 25.72 | 744.00 | 24.28 | 150.83 | 24.37 |
Report: ComfortReportSimple55Monthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 60.00 | 25.35 | 744.00 | 24.24 | 60.00 | 24.32 |
| February | 27.33 | 25.44 | 672.00 | 24.17 | 27.33 | 24.21 |
| March | 6.33 | 25.09 | 744.00 | 24.02 | 6.33 | 24.03 |
| April | 10.83 | 24.06 | 720.00 | 24.00 | 10.83 | 24.00 |
| May | 239.17 | 24.02 | 744.00 | 24.01 | 239.17 | 24.01 |
| June | 133.00 | 24.08 | 720.00 | 24.03 | 133.00 | 24.04 |
| July | 9.33 | 25.26 | 744.00 | 24.04 | 9.33 | 24.05 |
| August | 189.67 | 24.09 | 744.00 | 24.04 | 189.67 | 24.05 |
| September | 109.00 | 24.16 | 720.00 | 24.04 | 109.00 | 24.06 |
| October | 137.17 | 24.18 | 744.00 | 24.06 | 137.17 | 24.08 |
| November | 51.83 | 24.78 | 720.00 | 24.13 | 51.83 | 24.17 |
| December | 76.33 | 25.21 | 744.00 | 24.25 | 76.33 | 24.33 |
| Annual Sum or Average | 1050.00 | 24.33 | 8760.00 | 24.08 | 1050.00 | 24.11 |
| Minimum of Months | 6.33 | 24.02 | 672.00 | 24.00 | 6.33 | 24.00 |
| Maximum of Months | 239.17 | 25.44 | 744.00 | 24.25 | 239.17 | 24.33 |
Report: ComfortReportSimple55Monthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 60.00 | 25.35 | 744.00 | 24.24 | 60.00 | 24.32 |
| February | 27.17 | 25.45 | 672.00 | 24.17 | 27.17 | 24.21 |
| March | 6.33 | 25.09 | 744.00 | 24.02 | 6.33 | 24.03 |
| April | 11.00 | 24.06 | 720.00 | 24.00 | 11.00 | 24.00 |
| May | 238.00 | 24.02 | 744.00 | 24.01 | 238.00 | 24.01 |
| June | 132.50 | 24.08 | 720.00 | 24.03 | 132.50 | 24.04 |
| July | 9.17 | 25.26 | 744.00 | 24.04 | 9.17 | 24.05 |
| August | 187.83 | 24.10 | 744.00 | 24.04 | 187.83 | 24.05 |
| September | 108.33 | 24.16 | 720.00 | 24.04 | 108.33 | 24.06 |
| October | 137.17 | 24.18 | 744.00 | 24.06 | 137.17 | 24.08 |
| November | 51.50 | 24.79 | 720.00 | 24.13 | 51.50 | 24.17 |
| December | 76.33 | 25.21 | 744.00 | 24.25 | 76.33 | 24.33 |
| Annual Sum or Average | 1045.33 | 24.33 | 8760.00 | 24.08 | 1045.33 | 24.11 |
| Minimum of Months | 6.33 | 24.02 | 672.00 | 24.00 | 6.33 | 24.00 |
| Maximum of Months | 238.00 | 25.45 | 744.00 | 24.25 | 238.00 | 24.33 |
Report: ComfortReportSimple55Monthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 32.33 | 25.58 | 533.00 | 24.25 | 32.33 | 24.32 |
| February | 12.17 | 25.73 | 473.00 | 24.17 | 12.17 | 24.21 |
| March | 3.50 | 25.47 | 506.00 | 24.03 | 3.50 | 24.04 |
| April | 9.17 | 24.00 | 510.00 | 24.00 | 9.17 | 24.00 |
| May | 237.67 | 24.02 | 515.00 | 24.01 | 237.67 | 24.02 |
| June | 190.50 | 24.06 | 492.00 | 24.03 | 190.50 | 24.04 |
| July | 10.17 | 25.24 | 533.00 | 24.05 | 10.17 | 24.07 |
| August | 178.00 | 24.09 | 506.00 | 24.05 | 178.00 | 24.06 |
| September | 70.17 | 24.19 | 510.00 | 24.05 | 70.17 | 24.06 |
| October | 46.00 | 24.36 | 524.00 | 24.06 | 46.00 | 24.08 |
| November | 19.00 | 25.51 | 510.00 | 24.16 | 19.00 | 24.21 |
| December | 41.33 | 25.61 | 533.00 | 24.29 | 41.33 | 24.38 |
| Annual Sum or Average | 850.00 | 24.29 | 6145.00 | 24.09 | 850.00 | 24.11 |
| Minimum of Months | 3.50 | 24.00 | 473.00 | 24.00 | 3.50 | 24.00 |
| Maximum of Months | 237.67 | 25.73 | 533.00 | 24.29 | 237.67 | 24.38 |
Report: ComfortReportSimple55Monthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 23.17 | 25.77 | 533.00 | 24.25 | 23.17 | 24.31 |
| February | 7.50 | 25.91 | 473.00 | 24.17 | 7.50 | 24.20 |
| March | 2.17 | 25.71 | 506.00 | 24.03 | 2.17 | 24.03 |
| April | 0.00 | 0.00 | 510.00 | 24.00 | 0.00 | 24.00 |
| May | 121.00 | 24.04 | 515.00 | 24.02 | 121.00 | 24.02 |
| June | 73.17 | 24.14 | 492.00 | 24.04 | 73.17 | 24.05 |
| July | 8.33 | 25.34 | 533.00 | 24.05 | 8.33 | 24.07 |
| August | 77.00 | 24.22 | 506.00 | 24.06 | 77.00 | 24.08 |
| September | 13.50 | 25.00 | 510.00 | 24.05 | 13.50 | 24.08 |
| October | 12.33 | 25.25 | 524.00 | 24.07 | 12.33 | 24.09 |
| November | 13.67 | 25.70 | 510.00 | 24.16 | 13.67 | 24.20 |
| December | 34.83 | 25.77 | 533.00 | 24.30 | 34.83 | 24.38 |
| Annual Sum or Average | 386.67 | 24.56 | 6145.00 | 24.10 | 386.67 | 24.12 |
| Minimum of Months | 0.00 | 0.00 | 473.00 | 24.00 | 0.00 | 24.00 |
| Maximum of Months | 121.00 | 25.91 | 533.00 | 24.30 | 121.00 | 24.38 |
Report: ComfortReportSimple55Monthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 44.50 | 25.30 | 533.00 | 24.23 | 44.50 | 24.31 |
| February | 19.83 | 25.42 | 473.00 | 24.17 | 19.83 | 24.22 |
| March | 22.17 | 24.30 | 506.00 | 24.03 | 22.17 | 24.04 |
| April | 63.00 | 24.00 | 510.00 | 24.00 | 63.00 | 24.00 |
| May | 289.67 | 24.02 | 515.00 | 24.01 | 289.67 | 24.01 |
| June | 239.00 | 24.04 | 492.00 | 24.03 | 239.00 | 24.03 |
| July | 38.50 | 24.31 | 533.00 | 24.05 | 38.50 | 24.06 |
| August | 275.00 | 24.05 | 506.00 | 24.04 | 275.00 | 24.04 |
| September | 166.17 | 24.07 | 510.00 | 24.04 | 166.17 | 24.04 |
| October | 159.17 | 24.09 | 524.00 | 24.05 | 159.17 | 24.06 |
| November | 69.17 | 24.52 | 510.00 | 24.15 | 69.17 | 24.19 |
| December | 59.33 | 25.13 | 533.00 | 24.26 | 59.33 | 24.34 |
| Annual Sum or Average | 1445.50 | 24.18 | 6145.00 | 24.08 | 1445.50 | 24.10 |
| Minimum of Months | 19.83 | 24.00 | 473.00 | 24.00 | 19.83 | 24.00 |
| Maximum of Months | 289.67 | 25.42 | 533.00 | 24.26 | 289.67 | 24.34 |
Report: ComfortReportSimple55Monthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 75.67 | 25.00 | 744.00 | 24.21 | 75.67 | 24.28 |
| February | 36.67 | 25.18 | 672.00 | 24.16 | 36.67 | 24.21 |
| March | 29.33 | 24.25 | 744.00 | 24.02 | 29.33 | 24.03 |
| April | 60.00 | 24.01 | 720.00 | 24.00 | 60.00 | 24.00 |
| May | 303.00 | 24.02 | 744.00 | 24.01 | 303.00 | 24.01 |
| June | 216.50 | 24.05 | 720.00 | 24.03 | 216.50 | 24.03 |
| July | 24.50 | 24.54 | 744.00 | 24.04 | 24.50 | 24.05 |
| August | 323.83 | 24.05 | 744.00 | 24.03 | 323.83 | 24.04 |
| September | 195.67 | 24.08 | 720.00 | 24.04 | 195.67 | 24.04 |
| October | 219.50 | 24.10 | 744.00 | 24.05 | 219.50 | 24.06 |
| November | 121.50 | 24.34 | 720.00 | 24.11 | 121.50 | 24.14 |
| December | 114.33 | 24.71 | 744.00 | 24.20 | 114.33 | 24.26 |
| Annual Sum or Average | 1720.50 | 24.19 | 8760.00 | 24.07 | 1720.50 | 24.09 |
| Minimum of Months | 24.50 | 24.01 | 672.00 | 24.00 | 24.50 | 24.00 |
| Maximum of Months | 323.83 | 25.18 | 744.00 | 24.21 | 323.83 | 24.28 |
Report: ComfortReportSimple55Monthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 43.67 | 25.47 | 533.00 | 24.26 | 43.67 | 24.34 |
| February | 19.33 | 25.59 | 473.00 | 24.18 | 19.33 | 24.24 |
| March | 25.00 | 24.28 | 506.00 | 24.03 | 25.00 | 24.04 |
| April | 72.33 | 24.00 | 510.00 | 24.00 | 72.33 | 24.00 |
| May | 289.67 | 24.02 | 515.00 | 24.01 | 289.67 | 24.01 |
| June | 238.33 | 24.04 | 492.00 | 24.03 | 238.33 | 24.03 |
| July | 41.67 | 24.31 | 533.00 | 24.05 | 41.67 | 24.07 |
| August | 276.83 | 24.05 | 506.00 | 24.04 | 276.83 | 24.04 |
| September | 164.50 | 24.08 | 510.00 | 24.04 | 164.50 | 24.04 |
| October | 164.83 | 24.09 | 524.00 | 24.05 | 164.83 | 24.06 |
| November | 65.33 | 24.54 | 510.00 | 24.16 | 65.33 | 24.20 |
| December | 59.50 | 25.24 | 533.00 | 24.28 | 59.50 | 24.37 |
| Annual Sum or Average | 1461.00 | 24.19 | 6145.00 | 24.09 | 1461.00 | 24.10 |
| Minimum of Months | 19.33 | 24.00 | 473.00 | 24.00 | 19.33 | 24.00 |
| Maximum of Months | 289.67 | 25.59 | 533.00 | 24.28 | 289.67 | 24.37 |
Report: ComfortReportSimple55Monthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 75.00 | 25.17 | 744.00 | 24.24 | 75.00 | 24.32 |
| February | 34.50 | 25.38 | 672.00 | 24.18 | 34.50 | 24.23 |
| March | 36.00 | 24.22 | 744.00 | 24.02 | 36.00 | 24.03 |
| April | 78.00 | 24.01 | 720.00 | 24.00 | 78.00 | 24.00 |
| May | 297.17 | 24.02 | 744.00 | 24.01 | 297.17 | 24.01 |
| June | 209.67 | 24.06 | 720.00 | 24.03 | 209.67 | 24.03 |
| July | 24.83 | 24.55 | 744.00 | 24.04 | 24.83 | 24.06 |
| August | 298.67 | 24.06 | 744.00 | 24.03 | 298.67 | 24.04 |
| September | 197.00 | 24.08 | 720.00 | 24.04 | 197.00 | 24.04 |
| October | 216.17 | 24.11 | 744.00 | 24.05 | 216.17 | 24.06 |
| November | 122.50 | 24.37 | 720.00 | 24.12 | 122.50 | 24.15 |
| December | 109.50 | 24.85 | 744.00 | 24.23 | 109.50 | 24.30 |
| Annual Sum or Average | 1699.00 | 24.22 | 8760.00 | 24.08 | 1699.00 | 24.10 |
| Minimum of Months | 24.83 | 24.01 | 672.00 | 24.00 | 24.83 | 24.00 |
| Maximum of Months | 298.67 | 25.38 | 744.00 | 24.24 | 298.67 | 24.32 |
Report: ComfortReportSimple55Monthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 80.17 | 24.92 | 744.00 | 24.20 | 80.17 | 24.27 |
| February | 42.83 | 25.04 | 672.00 | 24.15 | 42.83 | 24.20 |
| March | 49.00 | 24.15 | 744.00 | 24.02 | 49.00 | 24.03 |
| April | 161.67 | 24.01 | 720.00 | 24.00 | 161.67 | 24.00 |
| May | 383.83 | 24.01 | 744.00 | 24.01 | 383.83 | 24.01 |
| June | 278.00 | 24.04 | 720.00 | 24.02 | 278.00 | 24.03 |
| July | 45.50 | 24.29 | 744.00 | 24.04 | 45.50 | 24.05 |
| August | 404.83 | 24.04 | 744.00 | 24.03 | 404.83 | 24.03 |
| September | 300.83 | 24.05 | 720.00 | 24.03 | 300.83 | 24.04 |
| October | 278.33 | 24.08 | 744.00 | 24.05 | 278.33 | 24.05 |
| November | 161.17 | 24.26 | 720.00 | 24.11 | 161.17 | 24.13 |
| December | 124.17 | 24.65 | 744.00 | 24.20 | 124.17 | 24.26 |
| Annual Sum or Average | 2310.33 | 24.14 | 8760.00 | 24.07 | 2310.33 | 24.08 |
| Minimum of Months | 42.83 | 24.01 | 672.00 | 24.00 | 42.83 | 24.00 |
| Maximum of Months | 404.83 | 25.04 | 744.00 | 24.20 | 404.83 | 24.27 |
Report: ComfortReportSimple55Monthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 80.17 | 24.93 | 744.00 | 24.20 | 80.17 | 24.27 |
| February | 42.83 | 25.04 | 672.00 | 24.15 | 42.83 | 24.20 |
| March | 49.83 | 24.15 | 744.00 | 24.02 | 49.83 | 24.03 |
| April | 162.33 | 24.01 | 720.00 | 24.00 | 162.33 | 24.00 |
| May | 383.33 | 24.01 | 744.00 | 24.01 | 383.33 | 24.01 |
| June | 276.67 | 24.04 | 720.00 | 24.02 | 276.67 | 24.03 |
| July | 45.50 | 24.29 | 744.00 | 24.04 | 45.50 | 24.05 |
| August | 403.50 | 24.04 | 744.00 | 24.03 | 403.50 | 24.03 |
| September | 298.50 | 24.05 | 720.00 | 24.03 | 298.50 | 24.04 |
| October | 277.33 | 24.08 | 744.00 | 24.05 | 277.33 | 24.05 |
| November | 161.00 | 24.26 | 720.00 | 24.11 | 161.00 | 24.13 |
| December | 124.17 | 24.65 | 744.00 | 24.20 | 124.17 | 24.26 |
| Annual Sum or Average | 2305.17 | 24.14 | 8760.00 | 24.07 | 2305.17 | 24.08 |
| Minimum of Months | 42.83 | 24.01 | 672.00 | 24.00 | 42.83 | 24.00 |
| Maximum of Months | 403.50 | 25.04 | 744.00 | 24.20 | 403.50 | 24.27 |
Report: ComfortReportSimple55Monthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 43.17 | 25.30 | 533.00 | 24.23 | 43.17 | 24.31 |
| February | 19.33 | 25.41 | 473.00 | 24.16 | 19.33 | 24.21 |
| March | 27.83 | 24.23 | 506.00 | 24.03 | 27.83 | 24.04 |
| April | 143.17 | 24.00 | 510.00 | 24.00 | 143.17 | 24.00 |
| May | 339.33 | 24.01 | 515.00 | 24.01 | 339.33 | 24.01 |
| June | 294.00 | 24.03 | 492.00 | 24.03 | 294.00 | 24.03 |
| July | 63.33 | 24.20 | 533.00 | 24.04 | 63.33 | 24.06 |
| August | 315.33 | 24.04 | 506.00 | 24.03 | 315.33 | 24.04 |
| September | 227.33 | 24.05 | 510.00 | 24.03 | 227.33 | 24.04 |
| October | 184.83 | 24.08 | 524.00 | 24.05 | 184.83 | 24.05 |
| November | 69.17 | 24.51 | 510.00 | 24.15 | 69.17 | 24.19 |
| December | 56.50 | 25.16 | 533.00 | 24.26 | 56.50 | 24.34 |
| Annual Sum or Average | 1783.33 | 24.15 | 6145.00 | 24.08 | 1783.33 | 24.09 |
| Minimum of Months | 19.33 | 24.00 | 473.00 | 24.00 | 19.33 | 24.00 |
| Maximum of Months | 339.33 | 25.41 | 533.00 | 24.26 | 339.33 | 24.34 |
Report: ComfortReportSimple55Monthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 43.00 | 25.31 | 533.00 | 24.23 | 43.00 | 24.31 |
| February | 19.33 | 25.41 | 473.00 | 24.16 | 19.33 | 24.21 |
| March | 27.83 | 24.23 | 506.00 | 24.03 | 27.83 | 24.04 |
| April | 144.50 | 24.00 | 510.00 | 24.00 | 144.50 | 24.00 |
| May | 339.67 | 24.01 | 515.00 | 24.01 | 339.67 | 24.01 |
| June | 293.67 | 24.03 | 492.00 | 24.03 | 293.67 | 24.03 |
| July | 63.33 | 24.20 | 533.00 | 24.04 | 63.33 | 24.06 |
| August | 315.17 | 24.04 | 506.00 | 24.03 | 315.17 | 24.04 |
| September | 226.33 | 24.05 | 510.00 | 24.03 | 226.33 | 24.04 |
| October | 184.83 | 24.08 | 524.00 | 24.05 | 184.83 | 24.05 |
| November | 69.00 | 24.51 | 510.00 | 24.15 | 69.00 | 24.19 |
| December | 56.50 | 25.16 | 533.00 | 24.26 | 56.50 | 24.34 |
| Annual Sum or Average | 1783.17 | 24.15 | 6145.00 | 24.08 | 1783.17 | 24.09 |
| Minimum of Months | 19.33 | 24.00 | 473.00 | 24.00 | 19.33 | 24.00 |
| Maximum of Months | 339.67 | 25.41 | 533.00 | 24.26 | 339.67 | 24.34 |
Report: ComfortReportSimple55Monthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 90.17 | 24.71 | 531.00 | 24.21 | 90.17 | 24.27 |
| February | 57.50 | 24.72 | 473.00 | 24.17 | 57.50 | 24.22 |
| March | 107.50 | 24.07 | 506.00 | 24.02 | 107.50 | 24.03 |
| April | 189.17 | 24.00 | 510.00 | 24.00 | 189.17 | 24.00 |
| May | 313.50 | 24.02 | 515.00 | 24.01 | 313.50 | 24.02 |
| June | 274.17 | 24.04 | 492.00 | 24.03 | 274.17 | 24.03 |
| July | 153.00 | 24.08 | 533.00 | 24.04 | 153.00 | 24.05 |
| August | 304.17 | 24.05 | 506.00 | 24.04 | 304.17 | 24.04 |
| September | 244.83 | 24.06 | 510.00 | 24.04 | 244.83 | 24.04 |
| October | 253.50 | 24.06 | 524.00 | 24.04 | 253.50 | 24.05 |
| November | 173.33 | 24.23 | 510.00 | 24.13 | 173.33 | 24.15 |
| December | 155.67 | 24.42 | 533.00 | 24.21 | 155.67 | 24.25 |
| Annual Sum or Average | 2316.50 | 24.13 | 6143.00 | 24.07 | 2316.50 | 24.08 |
| Minimum of Months | 57.50 | 24.00 | 473.00 | 24.00 | 57.50 | 24.00 |
| Maximum of Months | 313.50 | 24.72 | 533.00 | 24.21 | 313.50 | 24.27 |
Report: ComfortReportSimple55Monthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 132.17 | 24.59 | 741.67 | 24.19 | 132.17 | 24.24 |
| February | 91.83 | 24.59 | 672.00 | 24.15 | 91.83 | 24.20 |
| March | 131.33 | 24.06 | 744.00 | 24.02 | 131.33 | 24.02 |
| April | 197.33 | 24.01 | 720.00 | 24.00 | 197.33 | 24.00 |
| May | 349.83 | 24.02 | 744.00 | 24.01 | 349.83 | 24.01 |
| June | 284.00 | 24.04 | 720.00 | 24.02 | 284.00 | 24.03 |
| July | 147.67 | 24.09 | 744.00 | 24.03 | 147.67 | 24.04 |
| August | 367.17 | 24.05 | 744.00 | 24.03 | 367.17 | 24.04 |
| September | 285.33 | 24.06 | 720.00 | 24.04 | 285.33 | 24.04 |
| October | 316.83 | 24.07 | 744.00 | 24.05 | 316.83 | 24.05 |
| November | 221.83 | 24.20 | 720.00 | 24.10 | 221.83 | 24.12 |
| December | 212.17 | 24.36 | 744.00 | 24.17 | 212.17 | 24.20 |
| Annual Sum or Average | 2737.50 | 24.13 | 8757.67 | 24.07 | 2737.50 | 24.08 |
| Minimum of Months | 91.83 | 24.01 | 672.00 | 24.00 | 91.83 | 24.00 |
| Maximum of Months | 367.17 | 24.59 | 744.00 | 24.19 | 367.17 | 24.24 |
Report: ComfortReportSimple55Monthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 91.50 | 24.81 | 531.00 | 24.24 | 91.50 | 24.32 |
| February | 61.50 | 24.78 | 473.00 | 24.19 | 61.50 | 24.25 |
| March | 117.50 | 24.07 | 506.00 | 24.03 | 117.50 | 24.03 |
| April | 196.50 | 24.00 | 510.00 | 24.00 | 196.50 | 24.00 |
| May | 317.67 | 24.02 | 515.00 | 24.01 | 317.67 | 24.02 |
| June | 277.00 | 24.04 | 492.00 | 24.03 | 277.00 | 24.03 |
| July | 158.33 | 24.08 | 533.00 | 24.04 | 158.33 | 24.05 |
| August | 315.17 | 24.05 | 506.00 | 24.04 | 315.17 | 24.04 |
| September | 246.67 | 24.06 | 510.00 | 24.04 | 246.67 | 24.04 |
| October | 258.67 | 24.06 | 524.00 | 24.04 | 258.67 | 24.05 |
| November | 177.83 | 24.25 | 510.00 | 24.14 | 177.83 | 24.16 |
| December | 159.83 | 24.48 | 533.00 | 24.23 | 159.83 | 24.28 |
| Annual Sum or Average | 2378.17 | 24.14 | 6143.00 | 24.08 | 2378.17 | 24.09 |
| Minimum of Months | 61.50 | 24.00 | 473.00 | 24.00 | 61.50 | 24.00 |
| Maximum of Months | 317.67 | 24.81 | 533.00 | 24.24 | 317.67 | 24.32 |
Report: ComfortReportSimple55Monthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 134.00 | 24.73 | 741.83 | 24.24 | 134.00 | 24.30 |
| February | 90.33 | 24.73 | 672.00 | 24.19 | 90.33 | 24.25 |
| March | 134.50 | 24.06 | 744.00 | 24.02 | 134.50 | 24.02 |
| April | 195.67 | 24.01 | 720.00 | 24.00 | 195.67 | 24.00 |
| May | 340.67 | 24.02 | 744.00 | 24.01 | 340.67 | 24.01 |
| June | 275.17 | 24.04 | 720.00 | 24.03 | 275.17 | 24.03 |
| July | 148.50 | 24.10 | 744.00 | 24.04 | 148.50 | 24.04 |
| August | 349.83 | 24.05 | 744.00 | 24.03 | 349.83 | 24.04 |
| September | 271.50 | 24.07 | 720.00 | 24.04 | 271.50 | 24.04 |
| October | 305.33 | 24.08 | 744.00 | 24.05 | 305.33 | 24.05 |
| November | 218.33 | 24.23 | 720.00 | 24.12 | 218.33 | 24.14 |
| December | 209.67 | 24.44 | 744.00 | 24.20 | 209.67 | 24.25 |
| Annual Sum or Average | 2673.50 | 24.15 | 8757.83 | 24.08 | 2673.50 | 24.09 |
| Minimum of Months | 90.33 | 24.01 | 672.00 | 24.00 | 90.33 | 24.00 |
| Maximum of Months | 349.83 | 24.73 | 744.00 | 24.24 | 349.83 | 24.30 |
Report: ComfortReportSimple55Monthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 122.67 | 24.66 | 744.00 | 24.20 | 122.67 | 24.26 |
| February | 89.00 | 24.62 | 672.00 | 24.16 | 89.00 | 24.21 |
| March | 128.00 | 24.06 | 744.00 | 24.02 | 128.00 | 24.02 |
| April | 230.00 | 24.01 | 720.00 | 24.00 | 230.00 | 24.00 |
| May | 375.17 | 24.01 | 744.00 | 24.01 | 375.17 | 24.01 |
| June | 303.50 | 24.04 | 720.00 | 24.03 | 303.50 | 24.03 |
| July | 161.00 | 24.09 | 744.00 | 24.03 | 161.00 | 24.04 |
| August | 397.17 | 24.04 | 744.00 | 24.03 | 397.17 | 24.03 |
| September | 314.67 | 24.06 | 720.00 | 24.03 | 314.67 | 24.04 |
| October | 341.50 | 24.07 | 744.00 | 24.05 | 341.50 | 24.05 |
| November | 227.67 | 24.21 | 720.00 | 24.11 | 227.67 | 24.13 |
| December | 208.50 | 24.39 | 744.00 | 24.18 | 208.50 | 24.22 |
| Annual Sum or Average | 2898.83 | 24.13 | 8760.00 | 24.07 | 2898.83 | 24.08 |
| Minimum of Months | 89.00 | 24.01 | 672.00 | 24.00 | 89.00 | 24.00 |
| Maximum of Months | 397.17 | 24.66 | 744.00 | 24.20 | 397.17 | 24.26 |
Report: ComfortReportSimple55Monthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 122.67 | 24.67 | 744.00 | 24.20 | 122.67 | 24.26 |
| February | 88.83 | 24.62 | 672.00 | 24.16 | 88.83 | 24.21 |
| March | 129.17 | 24.06 | 744.00 | 24.02 | 129.17 | 24.02 |
| April | 231.00 | 24.01 | 720.00 | 24.00 | 231.00 | 24.00 |
| May | 374.33 | 24.01 | 744.00 | 24.01 | 374.33 | 24.01 |
| June | 303.00 | 24.04 | 720.00 | 24.02 | 303.00 | 24.03 |
| July | 160.67 | 24.09 | 744.00 | 24.03 | 160.67 | 24.04 |
| August | 396.00 | 24.04 | 744.00 | 24.03 | 396.00 | 24.03 |
| September | 313.67 | 24.06 | 720.00 | 24.03 | 313.67 | 24.04 |
| October | 339.17 | 24.07 | 744.00 | 24.05 | 339.17 | 24.05 |
| November | 227.17 | 24.21 | 720.00 | 24.11 | 227.17 | 24.13 |
| December | 208.00 | 24.40 | 744.00 | 24.18 | 208.00 | 24.22 |
| Annual Sum or Average | 2893.67 | 24.13 | 8760.00 | 24.07 | 2893.67 | 24.08 |
| Minimum of Months | 88.83 | 24.01 | 672.00 | 24.00 | 88.83 | 24.00 |
| Maximum of Months | 396.00 | 24.67 | 744.00 | 24.20 | 396.00 | 24.26 |
Report: ComfortReportSimple55Monthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 81.83 | 24.81 | 533.00 | 24.22 | 81.83 | 24.29 |
| February | 53.67 | 24.79 | 473.00 | 24.17 | 53.67 | 24.23 |
| March | 103.17 | 24.07 | 506.00 | 24.02 | 103.17 | 24.03 |
| April | 220.00 | 24.00 | 510.00 | 24.00 | 220.00 | 24.00 |
| May | 334.00 | 24.02 | 515.00 | 24.01 | 334.00 | 24.01 |
| June | 296.83 | 24.04 | 492.00 | 24.03 | 296.83 | 24.03 |
| July | 170.33 | 24.08 | 533.00 | 24.04 | 170.33 | 24.05 |
| August | 327.50 | 24.05 | 506.00 | 24.04 | 327.50 | 24.04 |
| September | 265.33 | 24.05 | 510.00 | 24.04 | 265.33 | 24.04 |
| October | 261.83 | 24.06 | 524.00 | 24.04 | 261.83 | 24.05 |
| November | 170.33 | 24.25 | 510.00 | 24.14 | 170.33 | 24.16 |
| December | 142.00 | 24.49 | 533.00 | 24.22 | 142.00 | 24.27 |
| Annual Sum or Average | 2426.83 | 24.12 | 6145.00 | 24.07 | 2426.83 | 24.09 |
| Minimum of Months | 53.67 | 24.00 | 473.00 | 24.00 | 53.67 | 24.00 |
| Maximum of Months | 334.00 | 24.81 | 533.00 | 24.22 | 334.00 | 24.29 |
Report: ComfortReportSimple55Monthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 82.83 | 24.80 | 533.00 | 24.22 | 82.83 | 24.29 |
| February | 54.83 | 24.78 | 473.00 | 24.18 | 54.83 | 24.23 |
| March | 105.17 | 24.07 | 506.00 | 24.02 | 105.17 | 24.03 |
| April | 223.17 | 24.00 | 510.00 | 24.00 | 223.17 | 24.00 |
| May | 335.50 | 24.02 | 515.00 | 24.01 | 335.50 | 24.01 |
| June | 298.83 | 24.04 | 492.00 | 24.03 | 298.83 | 24.03 |
| July | 172.83 | 24.08 | 533.00 | 24.04 | 172.83 | 24.05 |
| August | 329.17 | 24.05 | 506.00 | 24.04 | 329.17 | 24.04 |
| September | 267.00 | 24.05 | 510.00 | 24.03 | 267.00 | 24.04 |
| October | 264.33 | 24.06 | 524.00 | 24.04 | 264.33 | 24.05 |
| November | 172.00 | 24.24 | 510.00 | 24.14 | 172.00 | 24.16 |
| December | 144.17 | 24.49 | 533.00 | 24.22 | 144.17 | 24.27 |
| Annual Sum or Average | 2449.83 | 24.12 | 6145.00 | 24.07 | 2449.83 | 24.09 |
| Minimum of Months | 54.83 | 24.00 | 473.00 | 24.00 | 54.83 | 24.00 |
| Maximum of Months | 335.50 | 24.80 | 533.00 | 24.22 | 335.50 | 24.29 |
Report: ComfortReportSimple55Monthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 26.27 | 744.00 | 26.27 | 744.00 | 26.27 |
| February | 672.00 | 26.35 | 672.00 | 26.35 | 672.00 | 26.35 |
| March | 744.00 | 26.37 | 744.00 | 26.37 | 744.00 | 26.37 |
| April | 720.00 | 26.46 | 720.00 | 26.46 | 720.00 | 26.46 |
| May | 744.00 | 26.46 | 744.00 | 26.46 | 744.00 | 26.46 |
| June | 720.00 | 26.53 | 720.00 | 26.53 | 720.00 | 26.53 |
| July | 744.00 | 26.31 | 744.00 | 26.31 | 744.00 | 26.31 |
| August | 744.00 | 26.27 | 744.00 | 26.27 | 744.00 | 26.27 |
| September | 720.00 | 26.31 | 720.00 | 26.31 | 720.00 | 26.31 |
| October | 744.00 | 26.22 | 744.00 | 26.22 | 744.00 | 26.22 |
| November | 720.00 | 26.25 | 720.00 | 26.25 | 720.00 | 26.25 |
| December | 744.00 | 26.20 | 744.00 | 26.20 | 744.00 | 26.20 |
| Annual Sum or Average | 8760.00 | 26.33 | 8760.00 | 26.33 | 8760.00 | 26.33 |
| Minimum of Months | 672.00 | 26.20 | 672.00 | 26.20 | 672.00 | 26.20 |
| Maximum of Months | 744.00 | 26.53 | 744.00 | 26.53 | 744.00 | 26.53 |
Report: ComfortReportSimple55Monthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 741.83 | 27.73 | 744.00 | 27.72 | 741.83 | 27.72 |
| February | 671.50 | 27.94 | 672.00 | 27.94 | 671.50 | 27.94 |
| March | 744.00 | 28.03 | 744.00 | 28.03 | 744.00 | 28.03 |
| April | 720.00 | 28.17 | 720.00 | 28.17 | 720.00 | 28.17 |
| May | 744.00 | 28.19 | 744.00 | 28.19 | 744.00 | 28.19 |
| June | 720.00 | 28.24 | 720.00 | 28.24 | 720.00 | 28.24 |
| July | 744.00 | 27.83 | 744.00 | 27.83 | 744.00 | 27.83 |
| August | 744.00 | 27.83 | 744.00 | 27.83 | 744.00 | 27.83 |
| September | 720.00 | 27.85 | 720.00 | 27.85 | 720.00 | 27.85 |
| October | 744.00 | 27.66 | 744.00 | 27.66 | 744.00 | 27.66 |
| November | 720.00 | 27.69 | 720.00 | 27.69 | 720.00 | 27.69 |
| December | 744.00 | 27.63 | 744.00 | 27.63 | 744.00 | 27.63 |
| Annual Sum or Average | 8757.33 | 27.90 | 8760.00 | 27.90 | 8757.33 | 27.90 |
| Minimum of Months | 671.50 | 27.63 | 672.00 | 27.63 | 671.50 | 27.63 |
| Maximum of Months | 744.00 | 28.24 | 744.00 | 28.24 | 744.00 | 28.24 |
Report: ComfortReportSimple55Monthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 26.13 | 744.00 | 26.13 | 744.00 | 26.13 |
| February | 672.00 | 26.18 | 672.00 | 26.18 | 672.00 | 26.18 |
| March | 744.00 | 26.14 | 744.00 | 26.14 | 744.00 | 26.14 |
| April | 720.00 | 26.16 | 720.00 | 26.16 | 720.00 | 26.16 |
| May | 744.00 | 26.15 | 744.00 | 26.15 | 744.00 | 26.15 |
| June | 720.00 | 26.21 | 720.00 | 26.21 | 720.00 | 26.21 |
| July | 744.00 | 26.08 | 744.00 | 26.08 | 744.00 | 26.08 |
| August | 744.00 | 26.05 | 744.00 | 26.05 | 744.00 | 26.05 |
| September | 720.00 | 26.06 | 720.00 | 26.06 | 720.00 | 26.06 |
| October | 744.00 | 26.02 | 744.00 | 26.02 | 744.00 | 26.02 |
| November | 720.00 | 26.08 | 720.00 | 26.08 | 720.00 | 26.08 |
| December | 744.00 | 26.09 | 744.00 | 26.09 | 744.00 | 26.09 |
| Annual Sum or Average | 8760.00 | 26.11 | 8760.00 | 26.11 | 8760.00 | 26.11 |
| Minimum of Months | 672.00 | 26.02 | 672.00 | 26.02 | 672.00 | 26.02 |
| Maximum of Months | 744.00 | 26.21 | 744.00 | 26.21 | 744.00 | 26.21 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GSW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GNW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_OFFICE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 133.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 154.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 154.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 147.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 1750.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 133.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GNE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GN1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GN2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GS1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GS2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MSW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MNW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MSE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MNE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MN1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MN2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MS1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MS2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TSW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TNW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TSE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TNE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TN1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TN2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TS1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TS2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_T CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_G CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_M CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: SPLIT GSW HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.489624E+10 | 0.127660E+10 | 683.42 | 0.400777E+10 | 0.888461E+09 | 0.00 | 1.00 | 01-JAN-08:22 | 0.00 | 01-JAN-06:53 | 6487.75 | 02-JAN-08:62 | 5370.46 | 23-JAN-22:52 | 2361.38 | 02-JAN-08:03 | 1469.22 | 31-JAN-10:52 | 0.00 |
| February | 0.463927E+10 | 0.122383E+10 | 630.94 | 0.379716E+10 | 0.842119E+09 | 0.00 | 1.00 | 01-FEB-08:22 | 0.00 | 01-FEB-06:13 | 6430.40 | 10-FEB-08:32 | 5220.62 | 21-FEB-11:02 | 2102.83 | 10-FEB-08:33 | 1471.63 | 23-FEB-10:52 | 0.00 |
| March | 0.519164E+10 | 0.138203E+10 | 737.92 | 0.413994E+10 | 0.105170E+10 | 0.00 | 1.00 | 02-MAR-07:42 | 0.00 | 02-MAR-06:15 | 6506.58 | 15-MAR-07:22 | 4703.70 | 03-MAR-08:62 | 2427.29 | 15-MAR-07:23 | 1402.05 | 03-MAR-08:62 | 0.00 |
| April | 0.525246E+10 | 0.140317E+10 | 719.25 | 0.397657E+10 | 0.127589E+10 | 0.00 | 1.00 | 14-APR-16:52 | 0.00 | 14-APR-15:53 | 6230.69 | 14-APR-16:52 | 4749.24 | 14-APR-16:52 | 1585.34 | 14-APR-16:53 | 1458.53 | 14-APR-16:52 | 0.00 |
| May | 0.565174E+10 | 0.149802E+10 | 741.11 | 0.408329E+10 | 0.156844E+10 | 0.00 | 1.00 | 10-MAY-21:02 | 0.00 | 10-MAY-19:53 | 6414.78 | 31-MAY-21:42 | 4559.22 | 10-MAY-21:02 | 2039.40 | 31-MAY-21:43 | 1403.21 | 21-MAY-14:02 | 0.00 |
| June | 0.555914E+10 | 0.146980E+10 | 712.64 | 0.403546E+10 | 0.152368E+10 | 0.00 | 1.00 | 21-JUN-07:12 | 0.00 | 21-JUN-05:13 | 6476.36 | 27-JUN-07:12 | 4687.83 | 30-JUN-13:52 | 2387.24 | 27-JUN-07:13 | 1418.84 | 30-JUN-13:52 | 0.00 |
| July | 0.495111E+10 | 0.128951E+10 | 733.91 | 0.378547E+10 | 0.116564E+10 | 0.00 | 1.00 | 03-JUL-14:22 | 0.00 | 03-JUL-13:02 | 6457.78 | 13-JUL-06:52 | 4800.03 | 19-JUL-20:22 | 2278.74 | 13-JUL-06:53 | 1401.57 | 29-JUL-06:42 | 0.00 |
| August | 0.523417E+10 | 0.135663E+10 | 733.94 | 0.374955E+10 | 0.148462E+10 | 0.00 | 1.00 | 04-AUG-13:52 | 0.00 | 04-AUG-13:03 | 6586.14 | 20-AUG-13:12 | 4564.06 | 21-AUG-12:02 | 2864.91 | 20-AUG-13:13 | 1421.95 | 21-AUG-12:02 | 0.00 |
| September | 0.509718E+10 | 0.132490E+10 | 710.83 | 0.375151E+10 | 0.134567E+10 | 0.00 | 1.00 | 14-SEP-16:52 | 0.00 | 14-SEP-16:03 | 6541.97 | 15-SEP-21:52 | 4748.98 | 14-SEP-16:52 | 2593.90 | 15-SEP-21:53 | 1377.11 | 14-SEP-16:52 | 0.00 |
| October | 0.501737E+10 | 0.129222E+10 | 730.06 | 0.370856E+10 | 0.130881E+10 | 0.00 | 1.00 | 09-OCT-06:32 | 0.00 | 09-OCT-05:13 | 6593.79 | 23-OCT-07:52 | 4880.44 | 09-OCT-19:42 | 2845.61 | 23-OCT-07:53 | 1382.99 | 31-OCT-07:03 | 0.00 |
| November | 0.489585E+10 | 0.126387E+10 | 688.44 | 0.377959E+10 | 0.111626E+10 | 0.00 | 1.00 | 02-NOV-07:32 | 0.00 | 02-NOV-05:15 | 6493.42 | 26-NOV-10:02 | 5014.00 | 24-NOV-22:02 | 2379.84 | 02-NOV-07:33 | 1397.32 | 19-NOV-08:12 | 0.00 |
| December | 0.488334E+10 | 0.126183E+10 | 682.22 | 0.391771E+10 | 0.965636E+09 | 0.00 | 1.00 | 01-DEC-08:42 | 0.00 | 01-DEC-06:15 | 6521.08 | 20-DEC-08:32 | 5415.32 | 20-DEC-21:32 | 2462.41 | 20-DEC-08:33 | 1417.71 | 16-DEC-09:42 | 0.00 |
| Annual Sum or Average | 0.612695E+11 | 0.160424E+11 | 8504.69 | 0.467326E+11 | 0.145369E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.463927E+10 | 0.122383E+10 | 630.94 | 0.370856E+10 | 0.842119E+09 | 0.00 | 1.00 | 0.00 | 6230.69 | 4559.22 | 1585.34 | 1377.11 | 0.00 | ||||||
| Maximum of Months | 0.565174E+10 | 0.149802E+10 | 741.11 | 0.413994E+10 | 0.156844E+10 | 0.00 | 1.00 | 0.00 | 6593.79 | 5415.32 | 2864.91 | 1471.63 | 0.00 |
Report: DXReportMonthly
For: SPLIT GNW HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.412229E+10 | 0.108070E+10 | 674.02 | 0.328003E+10 | 0.842262E+09 | 0.00 | 1.00 | 01-JAN-08:22 | 0.00 | 01-JAN-06:53 | 6512.49 | 08-JAN-08:42 | 5320.15 | 23-JAN-22:52 | 2472.18 | 08-JAN-10:43 | 1479.54 | 31-JAN-10:52 | 0.00 |
| February | 0.406505E+10 | 0.107706E+10 | 626.67 | 0.325136E+10 | 0.813689E+09 | 0.00 | 1.00 | 01-FEB-09:12 | 0.00 | 01-FEB-06:13 | 6474.79 | 10-FEB-08:42 | 5087.90 | 24-FEB-09:02 | 2246.46 | 10-FEB-08:43 | 1486.36 | 21-FEB-11:12 | 0.00 |
| March | 0.492169E+10 | 0.131230E+10 | 737.72 | 0.387899E+10 | 0.104271E+10 | 0.00 | 1.00 | 02-MAR-07:42 | 0.00 | 02-MAR-06:15 | 6536.97 | 15-MAR-07:22 | 4696.85 | 03-MAR-08:62 | 2482.60 | 15-MAR-07:23 | 1406.72 | 03-MAR-08:62 | 0.00 |
| April | 0.531256E+10 | 0.141907E+10 | 719.25 | 0.402967E+10 | 0.128289E+10 | 0.00 | 1.00 | 14-APR-16:52 | 0.00 | 14-APR-15:53 | 6260.34 | 14-APR-16:52 | 4726.55 | 14-APR-16:52 | 1635.67 | 14-APR-16:53 | 1463.89 | 14-APR-16:52 | 0.00 |
| May | 0.592936E+10 | 0.156990E+10 | 741.14 | 0.433601E+10 | 0.159335E+10 | 0.00 | 1.00 | 10-MAY-21:02 | 0.00 | 10-MAY-19:53 | 6413.81 | 31-MAY-21:42 | 4605.59 | 10-MAY-21:02 | 1969.17 | 31-MAY-21:43 | 1407.49 | 21-MAY-14:02 | 0.00 |
| June | 0.603373E+10 | 0.159171E+10 | 712.92 | 0.447190E+10 | 0.156183E+10 | 0.00 | 1.00 | 21-JUN-07:12 | 0.00 | 21-JUN-05:13 | 6480.26 | 27-JUN-07:12 | 4808.30 | 25-JUN-19:52 | 2326.76 | 27-JUN-07:13 | 1423.20 | 30-JUN-13:52 | 0.00 |
| July | 0.523516E+10 | 0.136190E+10 | 735.34 | 0.404862E+10 | 0.118654E+10 | 0.00 | 1.00 | 03-JUL-14:22 | 0.00 | 03-JUL-13:02 | 6466.32 | 13-JUL-06:52 | 5010.84 | 19-JUL-19:52 | 2235.27 | 13-JUL-06:53 | 1406.00 | 29-JUL-06:42 | 0.00 |
| August | 0.540678E+10 | 0.140069E+10 | 734.19 | 0.390221E+10 | 0.150457E+10 | 0.00 | 1.00 | 04-AUG-13:52 | 0.00 | 04-AUG-13:03 | 6592.83 | 20-AUG-13:12 | 4579.06 | 23-AUG-21:02 | 2810.93 | 20-AUG-13:13 | 1426.76 | 21-AUG-12:02 | 0.00 |
| September | 0.504341E+10 | 0.131153E+10 | 710.89 | 0.369893E+10 | 0.134449E+10 | 0.00 | 1.00 | 14-SEP-16:52 | 0.00 | 14-SEP-16:03 | 6567.20 | 15-SEP-21:52 | 4713.34 | 14-SEP-16:52 | 2625.16 | 15-SEP-21:53 | 1381.76 | 14-SEP-16:52 | 0.00 |
| October | 0.473823E+10 | 0.122178E+10 | 729.19 | 0.344802E+10 | 0.129020E+10 | 0.00 | 1.00 | 09-OCT-06:32 | 0.00 | 09-OCT-05:13 | 6629.54 | 23-OCT-08:62 | 4796.85 | 09-OCT-20:02 | 2957.73 | 23-OCT-08:03 | 1387.44 | 31-OCT-07:03 | 0.00 |
| November | 0.435931E+10 | 0.112861E+10 | 685.15 | 0.327661E+10 | 0.108270E+10 | 0.00 | 1.00 | 02-NOV-07:42 | 0.00 | 02-NOV-05:15 | 6526.01 | 26-NOV-10:42 | 4925.98 | 25-NOV-20:02 | 2490.76 | 02-NOV-07:43 | 1402.07 | 19-NOV-08:12 | 0.00 |
| December | 0.411290E+10 | 0.106776E+10 | 676.71 | 0.319458E+10 | 0.918317E+09 | 0.00 | 1.00 | 01-DEC-08:42 | 0.00 | 01-DEC-06:15 | 6571.90 | 20-DEC-08:42 | 5330.64 | 20-DEC-22:02 | 2601.13 | 20-DEC-08:43 | 1423.35 | 16-DEC-09:42 | 0.00 |
| Annual Sum or Average | 0.592805E+11 | 0.155430E+11 | 8483.21 | 0.448169E+11 | 0.144635E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.406505E+10 | 0.106776E+10 | 626.67 | 0.319458E+10 | 0.813689E+09 | 0.00 | 1.00 | 0.00 | 6260.34 | 4579.06 | 1635.67 | 1381.76 | 0.00 | ||||||
| Maximum of Months | 0.603373E+10 | 0.159171E+10 | 741.14 | 0.447190E+10 | 0.159335E+10 | 0.00 | 1.00 | 0.00 | 6629.54 | 5330.64 | 2957.73 | 1486.36 | 0.00 |
Report: DXReportMonthly
For: SPLIT OFFICE HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.376448E+10 | 0.950619E+09 | 348.38 | 0.300136E+10 | 0.763117E+09 | 0.00 | 1.00 | 03-JAN-07:01 | 0.00 | 01-JAN-00:10 | 8016.72 | 09-JAN-07:01 | 6087.44 | 23-JAN-07:01 | 4114.55 | 10-JAN-07:08 | 1687.24 | 11-JAN-07:25 | 0.00 |
| February | 0.367906E+10 | 0.937686E+09 | 336.17 | 0.292934E+10 | 0.749717E+09 | 0.00 | 1.00 | 01-FEB-07:01 | 0.00 | 01-FEB-00:10 | 8016.72 | 06-FEB-07:01 | 5688.78 | 24-FEB-07:01 | 4221.08 | 16-FEB-07:08 | 1641.68 | 16-FEB-07:23 | 0.00 |
| March | 0.430603E+10 | 0.110708E+10 | 371.22 | 0.332713E+10 | 0.978900E+09 | 0.00 | 1.00 | 01-MAR-07:01 | 0.00 | 01-MAR-00:10 | 8016.90 | 15-MAR-06:01 | 5329.71 | 03-MAR-07:01 | 4426.63 | 28-MAR-06:09 | 1688.57 | 30-MAR-06:23 | 0.00 |
| April | 0.409933E+10 | 0.104822E+10 | 375.58 | 0.297514E+10 | 0.112419E+10 | 0.00 | 1.00 | 03-APR-06:01 | 0.00 | 01-APR-00:10 | 8013.46 | 24-APR-06:01 | 4681.02 | 17-APR-10:00 | 4628.19 | 19-APR-06:09 | 1696.67 | 11-APR-06:30 | 0.00 |
| May | 0.481329E+10 | 0.121475E+10 | 429.79 | 0.326315E+10 | 0.155014E+10 | 0.00 | 1.00 | 01-MAY-06:01 | 0.00 | 01-MAY-16:01 | 8016.66 | 09-MAY-06:03 | 4828.10 | 01-MAY-10:20 | 5265.60 | 19-MAY-06:06 | 1748.65 | 05-MAY-06:55 | 0.00 |
| June | 0.477888E+10 | 0.120783E+10 | 380.61 | 0.324829E+10 | 0.153059E+10 | 0.00 | 1.00 | 01-JUN-06:01 | 0.00 | 01-JUN-00:10 | 8016.90 | 21-JUN-06:02 | 4824.78 | 19-JUN-10:20 | 5065.87 | 29-JUN-06:07 | 1736.99 | 15-JUN-06:50 | 0.00 |
| July | 0.371369E+10 | 0.919640E+09 | 362.29 | 0.269643E+10 | 0.101726E+10 | 0.00 | 1.00 | 03-JUL-06:01 | 0.00 | 01-JUL-00:10 | 8016.66 | 12-JUL-06:01 | 4808.94 | 03-JUL-06:01 | 4371.87 | 11-JUL-06:06 | 1657.67 | 03-JUL-06:35 | 0.00 |
| August | 0.446832E+10 | 0.110550E+10 | 331.38 | 0.301512E+10 | 0.145320E+10 | 0.00 | 1.00 | 01-AUG-06:01 | 0.00 | 01-AUG-00:10 | 8016.29 | 30-AUG-06:01 | 4598.38 | 14-AUG-11:00 | 5035.19 | 11-AUG-06:07 | 1701.40 | 09-AUG-06:37 | 0.00 |
| September | 0.399520E+10 | 0.990447E+09 | 343.77 | 0.275944E+10 | 0.123576E+10 | 0.00 | 1.00 | 01-SEP-06:02 | 0.00 | 01-SEP-00:10 | 8016.53 | 18-SEP-06:11 | 4674.18 | 05-SEP-10:30 | 4769.16 | 01-SEP-06:08 | 1689.58 | 11-SEP-06:50 | 0.00 |
| October | 0.397098E+10 | 0.975728E+09 | 343.26 | 0.276810E+10 | 0.120288E+10 | 0.00 | 1.00 | 02-OCT-06:01 | 0.00 | 01-OCT-00:10 | 8016.90 | 23-OCT-06:01 | 4420.14 | 10-OCT-13:00 | 4786.45 | 26-OCT-06:07 | 1674.37 | 16-OCT-06:40 | 0.00 |
| November | 0.384307E+10 | 0.952785E+09 | 335.72 | 0.282539E+10 | 0.101769E+10 | 0.00 | 1.00 | 01-NOV-06:01 | 0.00 | 01-NOV-00:10 | 8016.86 | 06-NOV-07:01 | 5124.21 | 24-NOV-07:01 | 4511.77 | 03-NOV-06:07 | 1682.19 | 14-NOV-07:37 | 0.00 |
| December | 0.362844E+10 | 0.910136E+09 | 328.57 | 0.283893E+10 | 0.789514E+09 | 0.00 | 1.00 | 01-DEC-07:01 | 0.00 | 01-DEC-00:10 | 8016.90 | 04-DEC-07:01 | 5556.74 | 21-DEC-07:01 | 4234.30 | 12-DEC-07:06 | 1637.53 | 11-DEC-07:35 | 0.00 |
| Annual Sum or Average | 0.490608E+11 | 0.123204E+11 | 4286.74 | 0.356478E+11 | 0.134129E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.362844E+10 | 0.910136E+09 | 328.57 | 0.269643E+10 | 0.749717E+09 | 0.00 | 1.00 | 0.00 | 8013.46 | 4420.14 | 4114.55 | 1637.53 | 0.00 | ||||||
| Maximum of Months | 0.481329E+10 | 0.121475E+10 | 429.79 | 0.332713E+10 | 0.155014E+10 | 0.00 | 1.00 | 0.00 | 8016.90 | 6087.44 | 5265.60 | 1748.65 | 0.00 |
Report: DXReportMonthly
For: SPLIT GNE HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.410509E+10 | 0.107327E+10 | 672.72 | 0.326133E+10 | 0.843764E+09 | 0.00 | 1.00 | 01-JAN-08:22 | 0.00 | 01-JAN-06:53 | 6191.78 | 02-JAN-08:62 | 5064.79 | 23-JAN-22:52 | 2263.79 | 02-JAN-08:03 | 1404.12 | 31-JAN-10:52 | 0.00 |
| February | 0.406508E+10 | 0.107361E+10 | 627.29 | 0.324882E+10 | 0.816261E+09 | 0.00 | 1.00 | 01-FEB-09:12 | 0.00 | 01-FEB-06:13 | 6151.42 | 10-FEB-08:42 | 4929.12 | 21-FEB-11:12 | 2095.05 | 10-FEB-08:43 | 1410.81 | 23-FEB-11:02 | 0.00 |
| March | 0.489716E+10 | 0.130293E+10 | 738.03 | 0.385416E+10 | 0.104300E+10 | 0.00 | 1.00 | 02-MAR-07:42 | 0.00 | 02-MAR-06:15 | 6212.15 | 15-MAR-07:22 | 4478.92 | 03-MAR-08:62 | 2337.35 | 15-MAR-07:23 | 1337.71 | 03-MAR-08:62 | 0.00 |
| April | 0.531625E+10 | 0.141620E+10 | 719.22 | 0.403171E+10 | 0.128454E+10 | 0.00 | 1.00 | 14-APR-16:52 | 0.00 | 14-APR-15:53 | 5958.90 | 14-APR-16:52 | 4476.17 | 14-APR-16:52 | 1575.17 | 14-APR-16:53 | 1392.50 | 14-APR-16:52 | 0.00 |
| May | 0.594990E+10 | 0.157049E+10 | 741.08 | 0.435398E+10 | 0.159592E+10 | 0.00 | 1.00 | 10-MAY-21:02 | 0.00 | 10-MAY-19:53 | 6107.89 | 31-MAY-21:42 | 4350.06 | 10-MAY-21:02 | 1903.42 | 31-MAY-21:43 | 1338.53 | 21-MAY-14:02 | 0.00 |
| June | 0.605849E+10 | 0.159296E+10 | 712.92 | 0.449355E+10 | 0.156494E+10 | 0.00 | 1.00 | 21-JUN-07:12 | 0.00 | 21-JUN-05:13 | 6159.11 | 27-JUN-07:12 | 4541.65 | 30-JUN-13:52 | 2193.29 | 27-JUN-07:13 | 1353.09 | 30-JUN-13:52 | 0.00 |
| July | 0.524686E+10 | 0.136094E+10 | 735.46 | 0.405814E+10 | 0.118872E+10 | 0.00 | 1.00 | 03-JUL-14:22 | 0.00 | 03-JUL-13:02 | 6143.47 | 13-JUL-06:52 | 4690.47 | 19-JUL-19:52 | 2095.62 | 13-JUL-06:53 | 1337.09 | 29-JUL-06:42 | 0.00 |
| August | 0.543245E+10 | 0.140360E+10 | 734.14 | 0.392464E+10 | 0.150781E+10 | 0.00 | 1.00 | 04-AUG-13:52 | 0.00 | 04-AUG-13:03 | 6266.49 | 20-AUG-13:12 | 4378.60 | 21-AUG-12:02 | 2660.51 | 20-AUG-13:13 | 1356.39 | 21-AUG-12:02 | 0.00 |
| September | 0.507125E+10 | 0.131519E+10 | 710.64 | 0.372369E+10 | 0.134757E+10 | 0.00 | 1.00 | 14-SEP-16:52 | 0.00 | 14-SEP-16:03 | 6248.97 | 15-SEP-21:52 | 4482.16 | 14-SEP-16:52 | 2510.85 | 15-SEP-21:53 | 1314.07 | 14-SEP-16:52 | 0.00 |
| October | 0.474137E+10 | 0.121973E+10 | 729.33 | 0.344973E+10 | 0.129164E+10 | 0.00 | 1.00 | 09-OCT-06:32 | 0.00 | 09-OCT-05:13 | 6303.81 | 23-OCT-08:62 | 4546.90 | 09-OCT-20:02 | 2866.92 | 23-OCT-08:05 | 1319.50 | 31-OCT-07:03 | 0.00 |
| November | 0.436612E+10 | 0.112735E+10 | 686.12 | 0.328089E+10 | 0.108523E+10 | 0.00 | 1.00 | 02-NOV-07:42 | 0.00 | 02-NOV-05:15 | 6201.95 | 26-NOV-10:42 | 4681.24 | 25-NOV-20:02 | 2317.66 | 02-NOV-07:43 | 1333.40 | 19-NOV-08:12 | 0.00 |
| December | 0.410416E+10 | 0.106267E+10 | 676.18 | 0.318359E+10 | 0.920577E+09 | 0.00 | 1.00 | 01-DEC-08:42 | 0.00 | 01-DEC-06:15 | 6235.22 | 20-DEC-08:42 | 5054.64 | 20-DEC-22:02 | 2440.67 | 24-DEC-09:13 | 1353.29 | 16-DEC-09:42 | 0.00 |
| Annual Sum or Average | 0.593542E+11 | 0.155189E+11 | 8483.13 | 0.448642E+11 | 0.144900E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.406508E+10 | 0.106267E+10 | 627.29 | 0.318359E+10 | 0.816261E+09 | 0.00 | 1.00 | 0.00 | 5958.90 | 4350.06 | 1575.17 | 1314.07 | 0.00 | ||||||
| Maximum of Months | 0.605849E+10 | 0.159296E+10 | 741.08 | 0.449355E+10 | 0.159592E+10 | 0.00 | 1.00 | 0.00 | 6303.81 | 5064.79 | 2866.92 | 1410.81 | 0.00 |
Report: DXReportMonthly
For: SPLIT GN1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.353324E+10 | 0.922804E+09 | 671.42 | 0.273963E+10 | 0.793615E+09 | 0.00 | 1.00 | 01-JAN-08:22 | 0.00 | 01-JAN-06:53 | 5594.14 | 02-JAN-08:62 | 4510.92 | 23-JAN-22:52 | 2216.59 | 08-JAN-10:45 | 1272.02 | 31-JAN-10:52 | 0.00 |
| February | 0.343478E+10 | 0.907025E+09 | 625.68 | 0.267255E+10 | 0.762232E+09 | 0.00 | 1.00 | 01-FEB-09:12 | 0.00 | 01-FEB-06:13 | 5567.99 | 10-FEB-08:42 | 4313.31 | 24-FEB-09:02 | 1971.85 | 10-FEB-08:43 | 1278.06 | 21-FEB-11:12 | 0.00 |
| March | 0.408335E+10 | 0.108680E+10 | 737.03 | 0.312456E+10 | 0.958790E+09 | 0.00 | 1.00 | 02-MAR-07:42 | 0.00 | 02-MAR-06:15 | 5616.18 | 15-MAR-07:22 | 3999.81 | 03-MAR-08:62 | 2160.24 | 15-MAR-07:25 | 1208.59 | 03-MAR-08:62 | 0.00 |
| April | 0.444580E+10 | 0.118498E+10 | 719.08 | 0.325708E+10 | 0.118872E+10 | 0.00 | 1.00 | 14-APR-16:52 | 0.00 | 14-APR-15:53 | 5398.18 | 14-APR-16:52 | 3953.01 | 14-APR-16:52 | 1516.87 | 14-APR-16:53 | 1258.88 | 14-APR-16:52 | 0.00 |
| May | 0.508731E+10 | 0.134243E+10 | 740.89 | 0.360390E+10 | 0.148341E+10 | 0.00 | 1.00 | 10-MAY-21:02 | 0.00 | 10-MAY-19:53 | 5532.81 | 31-MAY-21:42 | 3860.15 | 10-MAY-21:02 | 1779.49 | 31-MAY-21:43 | 1209.41 | 21-MAY-14:02 | 0.00 |
| June | 0.516888E+10 | 0.135961E+10 | 712.64 | 0.371369E+10 | 0.145518E+10 | 0.00 | 1.00 | 21-JUN-07:12 | 0.00 | 21-JUN-05:13 | 5575.14 | 27-JUN-07:12 | 4032.16 | 24-JUN-19:52 | 2121.15 | 27-JUN-07:15 | 1223.18 | 30-JUN-13:52 | 0.00 |
| July | 0.452036E+10 | 0.117210E+10 | 735.07 | 0.340305E+10 | 0.111731E+10 | 0.00 | 1.00 | 03-JUL-14:22 | 0.00 | 03-JUL-13:02 | 5561.62 | 13-JUL-06:52 | 4186.43 | 19-JUL-19:52 | 1962.34 | 13-JUL-06:53 | 1208.05 | 29-JUL-06:42 | 0.00 |
| August | 0.465000E+10 | 0.120052E+10 | 734.14 | 0.325237E+10 | 0.139762E+10 | 0.00 | 1.00 | 04-AUG-13:52 | 0.00 | 04-AUG-13:03 | 5660.37 | 20-AUG-13:12 | 3835.77 | 21-AUG-12:02 | 2457.89 | 20-AUG-13:15 | 1226.17 | 21-AUG-12:02 | 0.00 |
| September | 0.432448E+10 | 0.112017E+10 | 710.47 | 0.306375E+10 | 0.126073E+10 | 0.00 | 1.00 | 14-SEP-16:52 | 0.00 | 14-SEP-16:03 | 5651.07 | 15-SEP-21:52 | 3956.39 | 14-SEP-16:52 | 2379.31 | 15-SEP-21:55 | 1187.29 | 14-SEP-16:52 | 0.00 |
| October | 0.412398E+10 | 0.105878E+10 | 728.50 | 0.290913E+10 | 0.121485E+10 | 0.00 | 1.00 | 09-OCT-06:32 | 0.00 | 09-OCT-05:13 | 5691.09 | 23-OCT-08:62 | 4010.31 | 09-OCT-20:02 | 2587.27 | 23-OCT-08:05 | 1192.20 | 31-OCT-07:05 | 0.00 |
| November | 0.379227E+10 | 0.977467E+09 | 684.40 | 0.276864E+10 | 0.102363E+10 | 0.00 | 1.00 | 02-NOV-07:42 | 0.00 | 02-NOV-05:15 | 5608.06 | 26-NOV-10:42 | 4144.17 | 25-NOV-20:02 | 2231.61 | 02-NOV-07:45 | 1204.62 | 19-NOV-08:12 | 0.00 |
| December | 0.356392E+10 | 0.921042E+09 | 671.83 | 0.269404E+10 | 0.869880E+09 | 0.00 | 1.00 | 01-DEC-08:42 | 0.00 | 01-DEC-06:15 | 5643.09 | 24-DEC-09:12 | 4514.44 | 20-DEC-22:02 | 2344.99 | 24-DEC-09:15 | 1222.88 | 16-DEC-09:42 | 0.00 |
| Annual Sum or Average | 0.507284E+11 | 0.132537E+11 | 8471.16 | 0.372024E+11 | 0.135260E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.343478E+10 | 0.907025E+09 | 625.68 | 0.267255E+10 | 0.762232E+09 | 0.00 | 1.00 | 0.00 | 5398.18 | 3835.77 | 1516.87 | 1187.29 | 0.00 | ||||||
| Maximum of Months | 0.516888E+10 | 0.135961E+10 | 740.89 | 0.371369E+10 | 0.148341E+10 | 0.00 | 1.00 | 0.00 | 5691.09 | 4514.44 | 2587.27 | 1278.06 | 0.00 |
Report: DXReportMonthly
For: SPLIT GN2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.353467E+10 | 0.923130E+09 | 671.45 | 0.274081E+10 | 0.793856E+09 | 0.00 | 1.00 | 01-JAN-08:22 | 0.00 | 01-JAN-06:53 | 5587.69 | 02-JAN-08:62 | 4506.33 | 23-JAN-22:52 | 2212.64 | 08-JAN-10:45 | 1270.52 | 31-JAN-10:52 | 0.00 |
| February | 0.343611E+10 | 0.907325E+09 | 625.84 | 0.267365E+10 | 0.762457E+09 | 0.00 | 1.00 | 01-FEB-09:12 | 0.00 | 01-FEB-06:13 | 5561.54 | 10-FEB-08:42 | 4308.35 | 24-FEB-09:02 | 1969.36 | 10-FEB-08:43 | 1276.55 | 21-FEB-11:12 | 0.00 |
| March | 0.408292E+10 | 0.108667E+10 | 737.03 | 0.312407E+10 | 0.958849E+09 | 0.00 | 1.00 | 02-MAR-07:42 | 0.00 | 02-MAR-06:15 | 5609.71 | 15-MAR-07:22 | 3994.84 | 03-MAR-08:62 | 2173.92 | 15-MAR-07:25 | 1207.21 | 03-MAR-08:62 | 0.00 |
| April | 0.444625E+10 | 0.118506E+10 | 719.08 | 0.325739E+10 | 0.118886E+10 | 0.00 | 1.00 | 14-APR-16:52 | 0.00 | 14-APR-15:53 | 5391.85 | 14-APR-16:52 | 3948.38 | 14-APR-16:52 | 1515.00 | 14-APR-16:53 | 1257.43 | 14-APR-16:52 | 0.00 |
| May | 0.508831E+10 | 0.134262E+10 | 740.89 | 0.360471E+10 | 0.148360E+10 | 0.00 | 1.00 | 10-MAY-21:02 | 0.00 | 10-MAY-19:53 | 5526.58 | 31-MAY-21:42 | 3854.49 | 10-MAY-21:02 | 1778.15 | 31-MAY-21:43 | 1208.02 | 21-MAY-14:02 | 0.00 |
| June | 0.517004E+10 | 0.135983E+10 | 712.64 | 0.371465E+10 | 0.145539E+10 | 0.00 | 1.00 | 21-JUN-07:12 | 0.00 | 21-JUN-05:13 | 5568.66 | 27-JUN-07:12 | 4027.35 | 24-JUN-19:52 | 2118.62 | 27-JUN-07:15 | 1221.76 | 30-JUN-13:52 | 0.00 |
| July | 0.452121E+10 | 0.117225E+10 | 735.07 | 0.340370E+10 | 0.111752E+10 | 0.00 | 1.00 | 03-JUL-14:22 | 0.00 | 03-JUL-13:02 | 5555.09 | 13-JUL-06:52 | 4180.07 | 19-JUL-19:52 | 1959.71 | 13-JUL-06:53 | 1206.67 | 29-JUL-06:42 | 0.00 |
| August | 0.465129E+10 | 0.120080E+10 | 734.14 | 0.325343E+10 | 0.139786E+10 | 0.00 | 1.00 | 04-AUG-13:52 | 0.00 | 04-AUG-13:03 | 5653.64 | 20-AUG-13:12 | 3832.41 | 21-AUG-12:02 | 2454.39 | 20-AUG-13:15 | 1224.75 | 21-AUG-12:02 | 0.00 |
| September | 0.432593E+10 | 0.112049E+10 | 710.50 | 0.306497E+10 | 0.126097E+10 | 0.00 | 1.00 | 14-SEP-16:52 | 0.00 | 14-SEP-16:03 | 5644.62 | 15-SEP-21:52 | 3951.92 | 14-SEP-16:52 | 2376.69 | 15-SEP-21:55 | 1185.93 | 14-SEP-16:52 | 0.00 |
| October | 0.412432E+10 | 0.105883E+10 | 728.50 | 0.290934E+10 | 0.121498E+10 | 0.00 | 1.00 | 09-OCT-06:32 | 0.00 | 09-OCT-05:13 | 5684.53 | 23-OCT-08:62 | 4005.55 | 09-OCT-20:02 | 2584.23 | 23-OCT-08:05 | 1190.83 | 31-OCT-07:05 | 0.00 |
| November | 0.379318E+10 | 0.977652E+09 | 684.40 | 0.276935E+10 | 0.102383E+10 | 0.00 | 1.00 | 02-NOV-07:42 | 0.00 | 02-NOV-05:15 | 5601.32 | 26-NOV-10:42 | 4139.64 | 25-NOV-20:02 | 2228.27 | 02-NOV-07:45 | 1203.24 | 19-NOV-08:12 | 0.00 |
| December | 0.356510E+10 | 0.921303E+09 | 672.25 | 0.269497E+10 | 0.870126E+09 | 0.00 | 1.00 | 01-DEC-08:42 | 0.00 | 01-DEC-06:15 | 5636.69 | 24-DEC-09:12 | 4508.75 | 20-DEC-22:02 | 2342.70 | 24-DEC-09:15 | 1221.47 | 16-DEC-09:42 | 0.00 |
| Annual Sum or Average | 0.507393E+11 | 0.132560E+11 | 8471.79 | 0.372110E+11 | 0.135283E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.343611E+10 | 0.907325E+09 | 625.84 | 0.267365E+10 | 0.762457E+09 | 0.00 | 1.00 | 0.00 | 5391.85 | 3832.41 | 1515.00 | 1185.93 | 0.00 | ||||||
| Maximum of Months | 0.517004E+10 | 0.135983E+10 | 740.89 | 0.371465E+10 | 0.148360E+10 | 0.00 | 1.00 | 0.00 | 5684.53 | 4508.75 | 2584.23 | 1276.55 | 0.00 |
Report: DXReportMonthly
For: SPLIT GS1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.435184E+10 | 0.113150E+10 | 682.47 | 0.349103E+10 | 0.860811E+09 | 0.00 | 1.00 | 01-JAN-08:22 | 0.00 | 01-JAN-06:53 | 5603.38 | 02-JAN-08:62 | 4567.34 | 23-JAN-22:52 | 2126.72 | 08-JAN-10:23 | 1269.48 | 31-JAN-10:52 | 0.00 |
| February | 0.404789E+10 | 0.106533E+10 | 630.50 | 0.323850E+10 | 0.809395E+09 | 0.00 | 1.00 | 01-FEB-08:22 | 0.00 | 01-FEB-06:13 | 5555.03 | 10-FEB-08:32 | 4436.65 | 21-FEB-11:02 | 1854.29 | 10-FEB-08:33 | 1272.34 | 23-FEB-10:52 | 0.00 |
| March | 0.438680E+10 | 0.116686E+10 | 737.56 | 0.340200E+10 | 0.984791E+09 | 0.00 | 1.00 | 02-MAR-07:42 | 0.00 | 02-MAR-06:15 | 5620.96 | 15-MAR-07:22 | 4008.75 | 03-MAR-08:62 | 2200.43 | 15-MAR-07:25 | 1211.63 | 03-MAR-08:62 | 0.00 |
| April | 0.440822E+10 | 0.117610E+10 | 719.03 | 0.321539E+10 | 0.119283E+10 | 0.00 | 1.00 | 14-APR-16:52 | 0.00 | 14-APR-15:53 | 5397.51 | 14-APR-16:52 | 3967.95 | 14-APR-16:52 | 1500.13 | 14-APR-16:53 | 1261.36 | 14-APR-16:52 | 0.00 |
| May | 0.482646E+10 | 0.127588E+10 | 741.06 | 0.336001E+10 | 0.146645E+10 | 0.00 | 1.00 | 10-MAY-21:02 | 0.00 | 10-MAY-19:53 | 5571.36 | 31-MAY-21:42 | 3794.89 | 10-MAY-21:02 | 1913.48 | 31-MAY-21:43 | 1212.86 | 21-MAY-14:02 | 0.00 |
| June | 0.470303E+10 | 0.124065E+10 | 712.47 | 0.328203E+10 | 0.142100E+10 | 0.00 | 1.00 | 21-JUN-07:12 | 0.00 | 21-JUN-05:13 | 5613.08 | 25-JUN-21:42 | 3948.11 | 24-JUN-19:52 | 2196.52 | 27-JUN-07:15 | 1226.46 | 30-JUN-13:52 | 0.00 |
| July | 0.425227E+10 | 0.110474E+10 | 733.54 | 0.314782E+10 | 0.110444E+10 | 0.00 | 1.00 | 03-JUL-14:22 | 0.00 | 03-JUL-13:02 | 5581.84 | 13-JUL-06:52 | 3988.77 | 19-JUL-20:22 | 2028.52 | 13-JUL-06:53 | 1211.40 | 29-JUL-06:42 | 0.00 |
| August | 0.449519E+10 | 0.116205E+10 | 733.97 | 0.310836E+10 | 0.138683E+10 | 0.00 | 1.00 | 04-AUG-13:52 | 0.00 | 04-AUG-13:03 | 5685.92 | 20-AUG-13:12 | 3849.71 | 21-AUG-12:02 | 2527.34 | 20-AUG-13:15 | 1229.20 | 21-AUG-12:02 | 0.00 |
| September | 0.440263E+10 | 0.114104E+10 | 710.44 | 0.312801E+10 | 0.127462E+10 | 0.00 | 1.00 | 14-SEP-16:52 | 0.00 | 14-SEP-16:03 | 5658.17 | 15-SEP-21:52 | 3992.22 | 14-SEP-16:52 | 2368.84 | 15-SEP-21:55 | 1190.34 | 14-SEP-16:52 | 0.00 |
| October | 0.443590E+10 | 0.113882E+10 | 729.78 | 0.318587E+10 | 0.125003E+10 | 0.00 | 1.00 | 09-OCT-06:32 | 0.00 | 09-OCT-05:13 | 5688.96 | 23-OCT-07:52 | 4107.00 | 09-OCT-19:42 | 2506.83 | 23-OCT-07:55 | 1195.44 | 31-OCT-07:05 | 0.00 |
| November | 0.436832E+10 | 0.112400E+10 | 688.24 | 0.329169E+10 | 0.107663E+10 | 0.00 | 1.00 | 02-NOV-07:32 | 0.00 | 02-NOV-05:15 | 5604.63 | 26-NOV-10:02 | 4268.39 | 24-NOV-22:02 | 2147.53 | 02-NOV-07:35 | 1207.64 | 19-NOV-08:12 | 0.00 |
| December | 0.437981E+10 | 0.112786E+10 | 681.72 | 0.344139E+10 | 0.938417E+09 | 0.00 | 1.00 | 01-DEC-08:42 | 0.00 | 01-DEC-06:15 | 5624.23 | 20-DEC-08:32 | 4623.03 | 20-DEC-21:32 | 2176.43 | 20-DEC-08:35 | 1225.17 | 16-DEC-09:42 | 0.00 |
| Annual Sum or Average | 0.530583E+11 | 0.138548E+11 | 8500.78 | 0.392921E+11 | 0.137662E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.404789E+10 | 0.106533E+10 | 630.50 | 0.310836E+10 | 0.809395E+09 | 0.00 | 1.00 | 0.00 | 5397.51 | 3794.89 | 1500.13 | 1190.34 | 0.00 | ||||||
| Maximum of Months | 0.482646E+10 | 0.127588E+10 | 741.06 | 0.349103E+10 | 0.146645E+10 | 0.00 | 1.00 | 0.00 | 5688.96 | 4623.03 | 2527.34 | 1272.34 | 0.00 |
Report: DXReportMonthly
For: SPLIT GS2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.464603E+10 | 0.120506E+10 | 682.53 | 0.376795E+10 | 0.878077E+09 | 0.00 | 1.00 | 01-JAN-08:22 | 0.00 | 01-JAN-06:53 | 5621.93 | 02-JAN-08:62 | 4658.14 | 23-JAN-22:52 | 2053.67 | 08-JAN-10:23 | 1278.95 | 31-JAN-10:52 | 0.00 |
| February | 0.431300E+10 | 0.113231E+10 | 630.62 | 0.348786E+10 | 0.825136E+09 | 0.00 | 1.00 | 01-FEB-08:22 | 0.00 | 01-FEB-06:13 | 5589.06 | 10-FEB-08:32 | 4601.19 | 21-FEB-10:42 | 1814.99 | 10-FEB-08:33 | 1281.45 | 23-FEB-10:52 | 0.00 |
| March | 0.468288E+10 | 0.124279E+10 | 738.00 | 0.367677E+10 | 0.100611E+10 | 0.00 | 1.00 | 02-MAR-07:42 | 0.00 | 02-MAR-06:15 | 5649.88 | 15-MAR-07:22 | 4085.66 | 03-MAR-08:62 | 2067.94 | 15-MAR-07:23 | 1221.34 | 03-MAR-08:62 | 0.00 |
| April | 0.472108E+10 | 0.125707E+10 | 719.08 | 0.350174E+10 | 0.121935E+10 | 0.00 | 1.00 | 14-APR-16:52 | 0.00 | 14-APR-15:53 | 5433.65 | 14-APR-16:52 | 4043.54 | 14-APR-16:52 | 1463.51 | 14-APR-16:53 | 1271.27 | 14-APR-16:52 | 0.00 |
| May | 0.515369E+10 | 0.136011E+10 | 741.22 | 0.365698E+10 | 0.149671E+10 | 0.00 | 1.00 | 10-MAY-21:02 | 0.00 | 10-MAY-19:53 | 5598.92 | 31-MAY-21:42 | 3883.69 | 21-MAY-14:02 | 1844.83 | 31-MAY-21:43 | 1222.57 | 21-MAY-14:02 | 0.00 |
| June | 0.501229E+10 | 0.131991E+10 | 712.42 | 0.356301E+10 | 0.144928E+10 | 0.00 | 1.00 | 21-JUN-07:12 | 0.00 | 21-JUN-05:13 | 5637.13 | 25-JUN-21:42 | 4046.75 | 24-JUN-19:52 | 2128.64 | 27-JUN-07:15 | 1236.31 | 30-JUN-13:52 | 0.00 |
| July | 0.456570E+10 | 0.118410E+10 | 734.11 | 0.343570E+10 | 0.113000E+10 | 0.00 | 1.00 | 03-JUL-14:22 | 0.00 | 03-JUL-13:02 | 5608.65 | 13-JUL-06:52 | 4067.74 | 19-JUL-20:22 | 1947.12 | 13-JUL-06:53 | 1221.27 | 29-JUL-06:42 | 0.00 |
| August | 0.478990E+10 | 0.123676E+10 | 733.78 | 0.337434E+10 | 0.141556E+10 | 0.00 | 1.00 | 04-AUG-13:52 | 0.00 | 04-AUG-13:03 | 5704.40 | 20-AUG-13:12 | 3939.67 | 21-AUG-12:02 | 2440.46 | 20-AUG-13:15 | 1238.88 | 21-AUG-12:02 | 0.00 |
| September | 0.470381E+10 | 0.121729E+10 | 710.58 | 0.340236E+10 | 0.130145E+10 | 0.00 | 1.00 | 14-SEP-16:52 | 0.00 | 14-SEP-16:03 | 5695.90 | 15-SEP-21:52 | 4063.79 | 14-SEP-16:52 | 2342.13 | 15-SEP-21:55 | 1200.08 | 14-SEP-16:52 | 0.00 |
| October | 0.474037E+10 | 0.121520E+10 | 730.22 | 0.346384E+10 | 0.127653E+10 | 0.00 | 1.00 | 09-OCT-06:32 | 0.00 | 09-OCT-05:13 | 5711.01 | 23-OCT-07:52 | 4211.11 | 09-OCT-19:42 | 2420.46 | 23-OCT-07:55 | 1205.32 | 31-OCT-07:03 | 0.00 |
| November | 0.465371E+10 | 0.119528E+10 | 688.31 | 0.355645E+10 | 0.109726E+10 | 0.00 | 1.00 | 02-NOV-07:32 | 0.00 | 02-NOV-05:15 | 5636.89 | 26-NOV-10:02 | 4331.98 | 24-NOV-22:02 | 2077.20 | 26-NOV-10:05 | 1217.07 | 19-NOV-08:12 | 0.00 |
| December | 0.465062E+10 | 0.119522E+10 | 682.14 | 0.369457E+10 | 0.956043E+09 | 0.00 | 1.00 | 01-DEC-08:42 | 0.00 | 01-DEC-06:15 | 5655.93 | 20-DEC-08:32 | 4671.22 | 20-DEC-21:32 | 2129.88 | 20-DEC-08:35 | 1236.02 | 24-DEC-09:55 | 0.00 |
| Annual Sum or Average | 0.566331E+11 | 0.147611E+11 | 8503.01 | 0.425816E+11 | 0.140515E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.431300E+10 | 0.113231E+10 | 630.62 | 0.337434E+10 | 0.825136E+09 | 0.00 | 1.00 | 0.00 | 5433.65 | 3883.69 | 1463.51 | 1200.08 | 0.00 | ||||||
| Maximum of Months | 0.515369E+10 | 0.136011E+10 | 741.22 | 0.376795E+10 | 0.149671E+10 | 0.00 | 1.00 | 0.00 | 5711.01 | 4671.22 | 2440.46 | 1281.45 | 0.00 |
Report: DXReportMonthly
For: SPLIT MSW HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.966162E+10 | 0.253266E+10 | 682.42 | 0.784877E+10 | 0.181285E+10 | 0.00 | 1.00 | 01-JAN-08:22 | 0.00 | 01-JAN-06:53 | 14272.61 | 08-JAN-10:12 | 11502.18 | 23-JAN-22:52 | 5624.12 | 08-JAN-10:13 | 3213.10 | 31-JAN-10:52 | 0.00 |
| February | 0.912978E+10 | 0.242266E+10 | 628.56 | 0.741016E+10 | 0.171962E+10 | 0.00 | 1.00 | 01-FEB-08:22 | 0.00 | 01-FEB-06:13 | 14132.70 | 10-FEB-08:32 | 11260.57 | 21-FEB-11:02 | 5010.73 | 10-FEB-08:33 | 3219.72 | 23-FEB-10:52 | 0.00 |
| March | 0.102775E+11 | 0.274933E+10 | 737.03 | 0.810431E+10 | 0.217324E+10 | 0.00 | 1.00 | 02-MAR-07:42 | 0.00 | 02-MAR-06:15 | 14281.94 | 15-MAR-07:22 | 10002.73 | 03-MAR-08:62 | 5859.53 | 15-MAR-07:23 | 3063.25 | 03-MAR-08:62 | 0.00 |
| April | 0.103365E+11 | 0.277460E+10 | 719.11 | 0.771446E+10 | 0.262199E+10 | 0.00 | 1.00 | 14-APR-16:52 | 0.00 | 14-APR-15:53 | 13652.51 | 14-APR-16:52 | 10176.65 | 14-APR-16:52 | 3710.48 | 14-APR-16:53 | 3188.16 | 14-APR-16:52 | 0.00 |
| May | 0.109853E+11 | 0.292650E+10 | 741.19 | 0.776589E+10 | 0.321936E+10 | 0.00 | 1.00 | 10-MAY-21:02 | 0.00 | 10-MAY-19:53 | 14125.81 | 31-MAY-21:42 | 9781.72 | 10-MAY-21:02 | 4955.88 | 31-MAY-21:43 | 3065.46 | 21-MAY-14:02 | 0.00 |
| June | 0.106994E+11 | 0.284441E+10 | 711.89 | 0.758014E+10 | 0.311923E+10 | 0.00 | 1.00 | 21-JUN-07:12 | 0.00 | 21-JUN-05:13 | 14230.01 | 25-JUN-21:42 | 9986.11 | 24-JUN-19:52 | 5748.07 | 27-JUN-07:13 | 3099.80 | 30-JUN-13:52 | 0.00 |
| July | 0.934197E+10 | 0.244694E+10 | 733.93 | 0.699445E+10 | 0.234751E+10 | 0.00 | 1.00 | 03-JUL-14:22 | 0.00 | 03-JUL-13:02 | 14154.39 | 22-JUL-08:62 | 10226.70 | 19-JUL-20:22 | 5444.44 | 13-JUL-06:53 | 3061.49 | 29-JUL-06:42 | 0.00 |
| August | 0.996730E+10 | 0.259493E+10 | 733.53 | 0.693940E+10 | 0.302790E+10 | 0.00 | 1.00 | 04-AUG-13:52 | 0.00 | 04-AUG-13:03 | 14567.43 | 20-AUG-13:12 | 9655.23 | 21-AUG-12:02 | 7106.36 | 20-AUG-13:13 | 3107.83 | 21-AUG-12:02 | 0.00 |
| September | 0.970527E+10 | 0.253586E+10 | 710.36 | 0.698458E+10 | 0.272070E+10 | 0.00 | 1.00 | 14-SEP-16:52 | 0.00 | 14-SEP-16:03 | 14412.99 | 18-SEP-08:32 | 10062.88 | 14-SEP-16:52 | 6330.49 | 18-SEP-08:33 | 3008.30 | 14-SEP-16:52 | 0.00 |
| October | 0.976591E+10 | 0.252647E+10 | 729.05 | 0.710495E+10 | 0.266096E+10 | 0.00 | 1.00 | 09-OCT-06:32 | 0.00 | 09-OCT-05:13 | 14525.82 | 23-OCT-07:52 | 10469.01 | 09-OCT-19:42 | 6998.91 | 23-OCT-07:53 | 3019.80 | 31-OCT-07:03 | 0.00 |
| November | 0.953132E+10 | 0.247320E+10 | 686.61 | 0.726907E+10 | 0.226225E+10 | 0.00 | 1.00 | 02-NOV-07:32 | 0.00 | 02-NOV-05:15 | 14288.97 | 26-NOV-10:02 | 10807.19 | 24-NOV-22:02 | 5760.11 | 02-NOV-07:33 | 3052.47 | 19-NOV-08:12 | 0.00 |
| December | 0.953131E+10 | 0.247660E+10 | 678.14 | 0.757559E+10 | 0.195572E+10 | 0.00 | 1.00 | 01-DEC-08:42 | 0.00 | 01-DEC-06:15 | 14389.73 | 20-DEC-08:32 | 11768.27 | 20-DEC-21:32 | 6077.14 | 20-DEC-08:33 | 3098.00 | 16-DEC-09:42 | 0.00 |
| Annual Sum or Average | 0.118933E+12 | 0.313042E+11 | 8491.82 | 0.892918E+11 | 0.296413E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.912978E+10 | 0.242266E+10 | 628.56 | 0.693940E+10 | 0.171962E+10 | 0.00 | 1.00 | 0.00 | 13652.51 | 9655.23 | 3710.48 | 3008.30 | 0.00 | ||||||
| Maximum of Months | 0.109853E+11 | 0.292650E+10 | 741.19 | 0.810431E+10 | 0.321936E+10 | 0.00 | 1.00 | 0.00 | 14567.43 | 11768.27 | 7106.36 | 3219.72 | 0.00 |
Report: DXReportMonthly
For: SPLIT MNW HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.799467E+10 | 0.210651E+10 | 668.43 | 0.629330E+10 | 0.170137E+10 | 0.00 | 1.00 | 01-JAN-08:22 | 0.00 | 01-JAN-06:53 | 14332.96 | 07-JAN-09:12 | 11423.32 | 23-JAN-22:52 | 5822.19 | 07-JAN-09:13 | 3240.35 | 31-JAN-10:52 | 0.00 |
| February | 0.790502E+10 | 0.210609E+10 | 621.97 | 0.625494E+10 | 0.165008E+10 | 0.00 | 1.00 | 01-FEB-09:12 | 0.00 | 01-FEB-06:13 | 14253.46 | 10-FEB-08:42 | 10927.19 | 24-FEB-09:02 | 5490.35 | 10-FEB-08:43 | 3255.74 | 21-FEB-11:12 | 0.00 |
| March | 0.969784E+10 | 0.259777E+10 | 737.00 | 0.755108E+10 | 0.214676E+10 | 0.00 | 1.00 | 02-MAR-07:42 | 0.00 | 02-MAR-06:15 | 14363.44 | 15-MAR-07:22 | 9961.44 | 03-MAR-08:62 | 6007.94 | 15-MAR-07:23 | 3076.35 | 03-MAR-08:62 | 0.00 |
| April | 0.104348E+11 | 0.280085E+10 | 719.11 | 0.780310E+10 | 0.263169E+10 | 0.00 | 1.00 | 14-APR-16:52 | 0.00 | 14-APR-15:53 | 13736.94 | 14-APR-16:52 | 10150.96 | 14-APR-16:52 | 3817.88 | 14-APR-16:53 | 3203.43 | 14-APR-16:52 | 0.00 |
| May | 0.115378E+11 | 0.307129E+10 | 741.08 | 0.826827E+10 | 0.326950E+10 | 0.00 | 1.00 | 10-MAY-21:02 | 0.00 | 10-MAY-19:53 | 14122.34 | 31-MAY-21:42 | 9906.90 | 10-MAY-21:02 | 4695.60 | 31-MAY-21:43 | 3078.36 | 21-MAY-14:02 | 0.00 |
| June | 0.116660E+11 | 0.309615E+10 | 712.25 | 0.846429E+10 | 0.320171E+10 | 0.00 | 1.00 | 21-JUN-07:12 | 0.00 | 21-JUN-05:13 | 14291.89 | 27-JUN-07:12 | 10247.72 | 25-JUN-19:52 | 5658.91 | 27-JUN-07:13 | 3112.82 | 30-JUN-13:52 | 0.00 |
| July | 0.990264E+10 | 0.259155E+10 | 734.52 | 0.751253E+10 | 0.239011E+10 | 0.00 | 1.00 | 03-JUL-14:22 | 0.00 | 03-JUL-13:02 | 14197.15 | 13-JUL-06:52 | 10724.42 | 19-JUL-19:52 | 5341.01 | 13-JUL-06:53 | 3074.58 | 29-JUL-06:42 | 0.00 |
| August | 0.103007E+11 | 0.268100E+10 | 733.44 | 0.723324E+10 | 0.306748E+10 | 0.00 | 1.00 | 04-AUG-13:52 | 0.00 | 04-AUG-13:03 | 14616.76 | 20-AUG-13:12 | 9656.28 | 21-AUG-12:02 | 7120.69 | 20-AUG-13:13 | 3121.46 | 21-AUG-12:02 | 0.00 |
| September | 0.956219E+10 | 0.249935E+10 | 709.92 | 0.685032E+10 | 0.271188E+10 | 0.00 | 1.00 | 14-SEP-16:52 | 0.00 | 14-SEP-16:03 | 14498.82 | 18-SEP-08:32 | 10010.03 | 14-SEP-16:52 | 6473.88 | 18-SEP-08:33 | 3021.45 | 14-SEP-16:52 | 0.00 |
| October | 0.915188E+10 | 0.236961E+10 | 728.42 | 0.653909E+10 | 0.261279E+10 | 0.00 | 1.00 | 09-OCT-06:32 | 0.00 | 09-OCT-05:13 | 14615.50 | 23-OCT-08:62 | 10273.57 | 09-OCT-20:02 | 7220.08 | 23-OCT-08:03 | 3032.83 | 31-OCT-07:03 | 0.00 |
| November | 0.837398E+10 | 0.217799E+10 | 683.94 | 0.619285E+10 | 0.218113E+10 | 0.00 | 1.00 | 02-NOV-07:42 | 0.00 | 02-NOV-05:15 | 14387.68 | 26-NOV-10:42 | 10600.73 | 25-NOV-20:02 | 6103.05 | 02-NOV-07:43 | 3065.64 | 19-NOV-08:12 | 0.00 |
| December | 0.787346E+10 | 0.205458E+10 | 669.19 | 0.603173E+10 | 0.184173E+10 | 0.00 | 1.00 | 01-DEC-08:42 | 0.00 | 01-DEC-06:15 | 14496.60 | 20-DEC-08:42 | 11379.39 | 20-DEC-22:02 | 6517.25 | 20-DEC-08:43 | 3112.33 | 16-DEC-09:42 | 0.00 |
| Annual Sum or Average | 0.114401E+12 | 0.301528E+11 | 8459.27 | 0.849947E+11 | 0.294062E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.787346E+10 | 0.205458E+10 | 621.97 | 0.603173E+10 | 0.165008E+10 | 0.00 | 1.00 | 0.00 | 13736.94 | 9656.28 | 3817.88 | 3021.45 | 0.00 | ||||||
| Maximum of Months | 0.116660E+11 | 0.309615E+10 | 741.08 | 0.846429E+10 | 0.326950E+10 | 0.00 | 1.00 | 0.00 | 14616.76 | 11423.32 | 7220.08 | 3255.74 | 0.00 |
Report: DXReportMonthly
For: SPLIT MSE HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.962524E+10 | 0.251452E+10 | 683.89 | 0.780715E+10 | 0.181808E+10 | 0.00 | 1.00 | 01-JAN-08:22 | 0.00 | 01-JAN-06:53 | 13443.64 | 08-JAN-10:12 | 10882.57 | 23-JAN-22:52 | 5181.11 | 08-JAN-10:23 | 3031.46 | 31-JAN-10:52 | 0.00 |
| February | 0.912968E+10 | 0.241328E+10 | 630.89 | 0.740429E+10 | 0.172538E+10 | 0.00 | 1.00 | 01-FEB-08:22 | 0.00 | 01-FEB-06:13 | 13333.35 | 10-FEB-08:32 | 11427.99 | 21-FEB-10:42 | 4588.59 | 10-FEB-08:33 | 3037.54 | 23-FEB-10:52 | 0.00 |
| March | 0.102195E+11 | 0.272731E+10 | 737.50 | 0.804482E+10 | 0.217473E+10 | 0.00 | 1.00 | 02-MAR-07:42 | 0.00 | 02-MAR-06:15 | 13512.85 | 15-MAR-07:22 | 9517.37 | 03-MAR-08:62 | 5475.66 | 15-MAR-07:23 | 2896.89 | 03-MAR-08:62 | 0.00 |
| April | 0.103430E+11 | 0.276887E+10 | 719.06 | 0.771623E+10 | 0.262680E+10 | 0.00 | 1.00 | 14-APR-16:52 | 0.00 | 14-APR-15:53 | 12925.20 | 14-APR-16:52 | 9522.24 | 14-APR-16:52 | 3609.35 | 14-APR-16:53 | 3015.89 | 14-APR-16:52 | 0.00 |
| May | 0.110323E+11 | 0.293055E+10 | 741.42 | 0.780497E+10 | 0.322732E+10 | 0.00 | 1.00 | 10-MAY-21:02 | 0.00 | 10-MAY-19:53 | 13386.10 | 31-MAY-21:42 | 9091.12 | 10-MAY-21:02 | 4803.95 | 31-MAY-21:43 | 2898.97 | 21-MAY-14:02 | 0.00 |
| June | 0.107609E+11 | 0.285221E+10 | 712.19 | 0.763136E+10 | 0.312949E+10 | 0.00 | 1.00 | 21-JUN-07:12 | 0.00 | 21-JUN-05:13 | 13546.68 | 25-JUN-21:42 | 9469.39 | 30-JUN-13:52 | 5527.99 | 25-JUN-21:43 | 2930.37 | 30-JUN-13:52 | 0.00 |
| July | 0.937246E+10 | 0.244804E+10 | 733.96 | 0.701798E+10 | 0.235448E+10 | 0.00 | 1.00 | 03-JUL-14:22 | 0.00 | 03-JUL-13:02 | 13399.52 | 19-JUL-21:52 | 9428.30 | 19-JUL-20:22 | 5050.79 | 13-JUL-06:53 | 2895.26 | 29-JUL-06:42 | 0.00 |
| August | 0.100289E+11 | 0.260475E+10 | 733.53 | 0.699129E+10 | 0.303765E+10 | 0.00 | 1.00 | 04-AUG-13:52 | 0.00 | 04-AUG-13:03 | 13754.34 | 20-AUG-13:12 | 9280.57 | 21-AUG-12:02 | 6696.01 | 20-AUG-13:15 | 2937.90 | 21-AUG-12:02 | 0.00 |
| September | 0.976677E+10 | 0.254518E+10 | 710.36 | 0.703786E+10 | 0.272891E+10 | 0.00 | 1.00 | 14-SEP-16:52 | 0.00 | 14-SEP-16:03 | 13609.72 | 15-SEP-20:52 | 9517.61 | 14-SEP-16:52 | 5933.02 | 15-SEP-21:53 | 2844.95 | 14-SEP-16:52 | 0.00 |
| October | 0.977438E+10 | 0.252225E+10 | 729.02 | 0.710933E+10 | 0.266505E+10 | 0.00 | 1.00 | 09-OCT-06:32 | 0.00 | 09-OCT-05:13 | 13739.14 | 23-OCT-07:52 | 9856.23 | 09-OCT-19:42 | 6608.82 | 23-OCT-07:53 | 2855.70 | 31-OCT-07:03 | 0.00 |
| November | 0.954100E+10 | 0.246803E+10 | 688.82 | 0.727349E+10 | 0.226750E+10 | 0.00 | 1.00 | 02-NOV-07:32 | 0.00 | 02-NOV-05:15 | 13499.26 | 26-NOV-10:02 | 10188.49 | 24-NOV-22:02 | 5294.55 | 26-NOV-10:03 | 2886.67 | 19-NOV-08:12 | 0.00 |
| December | 0.951306E+10 | 0.246368E+10 | 681.56 | 0.755165E+10 | 0.196141E+10 | 0.00 | 1.00 | 01-DEC-08:42 | 0.00 | 01-DEC-06:15 | 13541.39 | 20-DEC-08:32 | 11099.82 | 20-DEC-21:32 | 5424.61 | 20-DEC-08:33 | 2928.90 | 16-DEC-09:42 | 0.00 |
| Annual Sum or Average | 0.119107E+12 | 0.312587E+11 | 8502.19 | 0.893904E+11 | 0.297168E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.912968E+10 | 0.241328E+10 | 630.89 | 0.699129E+10 | 0.172538E+10 | 0.00 | 1.00 | 0.00 | 12925.20 | 9091.12 | 3609.35 | 2844.95 | 0.00 | ||||||
| Maximum of Months | 0.110323E+11 | 0.293055E+10 | 741.42 | 0.804482E+10 | 0.322732E+10 | 0.00 | 1.00 | 0.00 | 13754.34 | 11427.99 | 6696.01 | 3037.54 | 0.00 |
Report: DXReportMonthly
For: SPLIT MNE HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.795107E+10 | 0.208863E+10 | 673.57 | 0.624877E+10 | 0.170229E+10 | 0.00 | 1.00 | 01-JAN-08:22 | 0.00 | 01-JAN-06:53 | 13497.11 | 07-JAN-09:12 | 10820.51 | 23-JAN-22:52 | 5241.60 | 02-JAN-08:03 | 3052.80 | 31-JAN-10:52 | 0.00 |
| February | 0.790133E+10 | 0.209736E+10 | 626.40 | 0.624828E+10 | 0.165305E+10 | 0.00 | 1.00 | 01-FEB-09:12 | 0.00 | 01-FEB-06:13 | 13441.68 | 10-FEB-08:42 | 10593.99 | 21-FEB-11:12 | 4933.11 | 10-FEB-08:43 | 3067.65 | 23-FEB-11:02 | 0.00 |
| March | 0.963626E+10 | 0.257521E+10 | 737.31 | 0.749313E+10 | 0.214313E+10 | 0.00 | 1.00 | 02-MAR-07:42 | 0.00 | 02-MAR-06:15 | 13575.10 | 15-MAR-07:22 | 9514.76 | 03-MAR-08:62 | 5602.18 | 15-MAR-07:23 | 2906.17 | 03-MAR-08:62 | 0.00 |
| April | 0.104368E+11 | 0.279325E+10 | 719.06 | 0.780553E+10 | 0.263125E+10 | 0.00 | 1.00 | 14-APR-16:52 | 0.00 | 14-APR-15:53 | 12994.72 | 14-APR-16:52 | 9505.41 | 14-APR-16:52 | 3695.94 | 14-APR-16:53 | 3026.99 | 14-APR-16:52 | 0.00 |
| May | 0.115791E+11 | 0.307225E+10 | 741.14 | 0.830769E+10 | 0.327142E+10 | 0.00 | 1.00 | 10-MAY-21:02 | 0.00 | 10-MAY-19:53 | 13365.36 | 31-MAY-21:42 | 9289.62 | 10-MAY-21:02 | 4528.18 | 31-MAY-21:43 | 2907.72 | 21-MAY-14:02 | 0.00 |
| June | 0.117204E+11 | 0.309978E+10 | 712.78 | 0.851519E+10 | 0.320522E+10 | 0.00 | 1.00 | 21-JUN-07:12 | 0.00 | 21-JUN-05:13 | 13491.93 | 27-JUN-07:12 | 9630.47 | 30-JUN-13:52 | 5269.18 | 27-JUN-07:13 | 2939.38 | 30-JUN-13:52 | 0.00 |
| July | 0.992739E+10 | 0.258985E+10 | 734.41 | 0.753588E+10 | 0.239150E+10 | 0.00 | 1.00 | 03-JUL-14:22 | 0.00 | 03-JUL-13:02 | 13427.80 | 13-JUL-06:52 | 9950.40 | 19-JUL-19:52 | 4940.27 | 13-JUL-06:53 | 2904.18 | 29-JUL-06:42 | 0.00 |
| August | 0.103575E+11 | 0.268850E+10 | 733.69 | 0.728575E+10 | 0.307175E+10 | 0.00 | 1.00 | 04-AUG-13:52 | 0.00 | 04-AUG-13:03 | 13789.11 | 20-AUG-13:12 | 9280.62 | 21-AUG-12:02 | 6618.63 | 20-AUG-13:13 | 2947.38 | 21-AUG-12:02 | 0.00 |
| September | 0.961970E+10 | 0.250741E+10 | 709.86 | 0.690469E+10 | 0.271501E+10 | 0.00 | 1.00 | 14-SEP-16:52 | 0.00 | 14-SEP-16:03 | 13679.61 | 15-SEP-20:52 | 9466.86 | 14-SEP-16:52 | 6035.29 | 15-SEP-21:53 | 2853.98 | 14-SEP-16:52 | 0.00 |
| October | 0.915755E+10 | 0.236517E+10 | 728.42 | 0.654482E+10 | 0.261273E+10 | 0.00 | 1.00 | 09-OCT-06:32 | 0.00 | 09-OCT-05:13 | 13808.52 | 23-OCT-08:62 | 9638.94 | 09-OCT-20:02 | 6802.72 | 23-OCT-08:03 | 2864.56 | 31-OCT-07:03 | 0.00 |
| November | 0.838289E+10 | 0.217387E+10 | 684.72 | 0.619967E+10 | 0.218322E+10 | 0.00 | 1.00 | 02-NOV-07:42 | 0.00 | 02-NOV-05:15 | 13577.22 | 26-NOV-10:42 | 10015.93 | 25-NOV-20:02 | 5581.15 | 02-NOV-07:43 | 2895.75 | 19-NOV-08:12 | 0.00 |
| December | 0.785388E+10 | 0.204305E+10 | 674.03 | 0.600768E+10 | 0.184620E+10 | 0.00 | 1.00 | 01-DEC-08:42 | 0.00 | 01-DEC-06:15 | 13705.02 | 20-DEC-08:42 | 10719.01 | 20-DEC-22:02 | 5942.37 | 20-DEC-08:43 | 2939.59 | 16-DEC-09:42 | 0.00 |
| Annual Sum or Average | 0.114524E+12 | 0.300943E+11 | 8475.38 | 0.850971E+11 | 0.294268E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.785388E+10 | 0.204305E+10 | 626.40 | 0.600768E+10 | 0.165305E+10 | 0.00 | 1.00 | 0.00 | 12994.72 | 9280.62 | 3695.94 | 2853.98 | 0.00 | ||||||
| Maximum of Months | 0.117204E+11 | 0.309978E+10 | 741.14 | 0.851519E+10 | 0.327142E+10 | 0.00 | 1.00 | 0.00 | 13808.52 | 10820.51 | 6802.72 | 3067.65 | 0.00 |
Report: DXReportMonthly
For: SPLIT MN1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.674060E+10 | 0.176881E+10 | 667.90 | 0.516982E+10 | 0.157078E+10 | 0.00 | 1.00 | 01-JAN-08:22 | 0.00 | 01-JAN-06:53 | 12192.89 | 27-JAN-08:42 | 9647.10 | 23-JAN-22:52 | 5087.12 | 08-JAN-10:45 | 2761.76 | 31-JAN-10:52 | 0.00 |
| February | 0.655459E+10 | 0.173963E+10 | 622.04 | 0.504299E+10 | 0.151160E+10 | 0.00 | 1.00 | 01-FEB-09:12 | 0.00 | 01-FEB-06:13 | 12140.21 | 10-FEB-08:42 | 9205.45 | 24-FEB-09:02 | 4708.12 | 10-FEB-08:43 | 2776.07 | 21-FEB-11:12 | 0.00 |
| March | 0.785788E+10 | 0.210052E+10 | 737.06 | 0.593675E+10 | 0.192113E+10 | 0.00 | 1.00 | 02-MAR-07:42 | 0.00 | 02-MAR-06:15 | 12232.07 | 15-MAR-07:22 | 8448.04 | 03-MAR-08:62 | 5107.86 | 15-MAR-07:23 | 2621.38 | 03-MAR-08:62 | 0.00 |
| April | 0.854461E+10 | 0.228803E+10 | 719.00 | 0.616390E+10 | 0.238072E+10 | 0.00 | 1.00 | 14-APR-16:52 | 0.00 | 14-APR-15:53 | 11746.14 | 14-APR-16:52 | 8366.02 | 14-APR-16:52 | 3537.85 | 14-APR-16:53 | 2732.20 | 14-APR-16:52 | 0.00 |
| May | 0.974097E+10 | 0.258368E+10 | 741.19 | 0.676308E+10 | 0.297788E+10 | 0.00 | 1.00 | 10-MAY-21:02 | 0.00 | 10-MAY-19:53 | 12082.61 | 31-MAY-21:42 | 8151.82 | 10-MAY-21:02 | 4204.82 | 31-MAY-21:43 | 2623.40 | 21-MAY-14:02 | 0.00 |
| June | 0.985777E+10 | 0.260799E+10 | 711.92 | 0.693814E+10 | 0.291963E+10 | 0.00 | 1.00 | 21-JUN-07:12 | 0.00 | 21-JUN-05:13 | 12186.49 | 25-JUN-21:42 | 8578.65 | 24-JUN-19:52 | 4850.40 | 27-JUN-07:13 | 2653.50 | 30-JUN-13:52 | 0.00 |
| July | 0.849022E+10 | 0.221326E+10 | 734.69 | 0.627893E+10 | 0.221130E+10 | 0.00 | 1.00 | 03-JUL-14:22 | 0.00 | 03-JUL-13:02 | 12101.20 | 13-JUL-06:52 | 8875.73 | 19-JUL-19:52 | 4574.84 | 13-JUL-06:53 | 2620.15 | 29-JUL-06:42 | 0.00 |
| August | 0.877265E+10 | 0.227453E+10 | 733.14 | 0.598073E+10 | 0.279192E+10 | 0.00 | 1.00 | 04-AUG-13:52 | 0.00 | 04-AUG-13:03 | 12433.94 | 20-AUG-13:12 | 8111.30 | 21-AUG-12:02 | 6076.21 | 20-AUG-13:15 | 2660.69 | 21-AUG-12:02 | 0.00 |
| September | 0.812427E+10 | 0.211366E+10 | 709.89 | 0.562518E+10 | 0.249909E+10 | 0.00 | 1.00 | 14-SEP-16:52 | 0.00 | 14-SEP-16:03 | 12424.17 | 15-SEP-20:52 | 8312.18 | 14-SEP-16:52 | 5847.58 | 15-SEP-20:55 | 2574.93 | 14-SEP-16:52 | 0.00 |
| October | 0.786929E+10 | 0.202782E+10 | 728.03 | 0.545334E+10 | 0.241595E+10 | 0.00 | 1.00 | 09-OCT-06:32 | 0.00 | 09-OCT-05:13 | 12435.05 | 23-OCT-08:62 | 8535.49 | 09-OCT-20:02 | 6150.73 | 23-OCT-08:05 | 2584.57 | 31-OCT-07:03 | 0.00 |
| November | 0.720229E+10 | 0.186388E+10 | 682.65 | 0.517429E+10 | 0.202800E+10 | 0.00 | 1.00 | 02-NOV-07:42 | 0.00 | 02-NOV-05:15 | 12282.35 | 26-NOV-10:42 | 8862.55 | 25-NOV-20:02 | 5233.79 | 26-NOV-10:45 | 2612.48 | 19-NOV-08:12 | 0.00 |
| December | 0.674970E+10 | 0.175252E+10 | 669.42 | 0.503327E+10 | 0.171643E+10 | 0.00 | 1.00 | 01-DEC-08:42 | 0.00 | 01-DEC-06:15 | 12350.48 | 24-DEC-09:12 | 9579.05 | 20-DEC-22:02 | 5610.06 | 24-DEC-09:13 | 2652.19 | 16-DEC-09:42 | 0.00 |
| Annual Sum or Average | 0.965048E+11 | 0.253343E+11 | 8456.92 | 0.695604E+11 | 0.269444E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.655459E+10 | 0.173963E+10 | 622.04 | 0.503327E+10 | 0.151160E+10 | 0.00 | 1.00 | 0.00 | 11746.14 | 8111.30 | 3537.85 | 2574.93 | 0.00 | ||||||
| Maximum of Months | 0.985777E+10 | 0.260799E+10 | 741.19 | 0.693814E+10 | 0.297788E+10 | 0.00 | 1.00 | 0.00 | 12435.05 | 9647.10 | 6150.73 | 2776.07 | 0.00 |
Report: DXReportMonthly
For: SPLIT MN2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.674484E+10 | 0.176983E+10 | 667.93 | 0.517345E+10 | 0.157139E+10 | 0.00 | 1.00 | 01-JAN-08:22 | 0.00 | 01-JAN-06:53 | 12178.27 | 27-JAN-08:42 | 9636.88 | 23-JAN-22:52 | 5051.17 | 08-JAN-10:45 | 2758.32 | 31-JAN-10:52 | 0.00 |
| February | 0.655831E+10 | 0.174052E+10 | 622.04 | 0.504614E+10 | 0.151217E+10 | 0.00 | 1.00 | 01-FEB-09:12 | 0.00 | 01-FEB-06:13 | 12125.85 | 10-FEB-08:42 | 9198.73 | 24-FEB-09:02 | 4701.38 | 10-FEB-08:43 | 2772.63 | 21-FEB-11:12 | 0.00 |
| March | 0.785713E+10 | 0.210031E+10 | 737.06 | 0.593590E+10 | 0.192123E+10 | 0.00 | 1.00 | 02-MAR-07:42 | 0.00 | 02-MAR-06:15 | 12216.98 | 15-MAR-07:22 | 8437.91 | 03-MAR-08:62 | 5100.18 | 15-MAR-07:23 | 2618.17 | 03-MAR-08:62 | 0.00 |
| April | 0.854556E+10 | 0.228822E+10 | 719.00 | 0.616459E+10 | 0.238097E+10 | 0.00 | 1.00 | 14-APR-16:52 | 0.00 | 14-APR-15:53 | 11731.39 | 14-APR-16:52 | 8354.72 | 14-APR-16:52 | 3533.91 | 14-APR-16:53 | 2728.83 | 14-APR-16:52 | 0.00 |
| May | 0.974300E+10 | 0.258410E+10 | 741.19 | 0.676475E+10 | 0.297825E+10 | 0.00 | 1.00 | 10-MAY-21:02 | 0.00 | 10-MAY-19:53 | 12068.23 | 31-MAY-21:42 | 8138.05 | 10-MAY-21:02 | 4202.27 | 31-MAY-21:43 | 2620.19 | 21-MAY-14:02 | 0.00 |
| June | 0.986025E+10 | 0.260850E+10 | 711.92 | 0.694020E+10 | 0.292005E+10 | 0.00 | 1.00 | 21-JUN-07:12 | 0.00 | 21-JUN-05:13 | 12172.26 | 25-JUN-21:42 | 8567.79 | 24-JUN-19:52 | 4843.96 | 27-JUN-07:13 | 2650.20 | 30-JUN-13:52 | 0.00 |
| July | 0.849197E+10 | 0.221361E+10 | 734.67 | 0.628030E+10 | 0.221168E+10 | 0.00 | 1.00 | 03-JUL-14:22 | 0.00 | 03-JUL-13:02 | 12086.43 | 13-JUL-06:52 | 8860.63 | 19-JUL-19:52 | 4567.98 | 13-JUL-06:53 | 2616.94 | 29-JUL-06:42 | 0.00 |
| August | 0.877537E+10 | 0.227515E+10 | 733.14 | 0.598295E+10 | 0.279243E+10 | 0.00 | 1.00 | 04-AUG-13:52 | 0.00 | 04-AUG-13:03 | 12418.63 | 20-AUG-13:12 | 8103.98 | 21-AUG-12:02 | 6067.74 | 20-AUG-13:15 | 2657.40 | 21-AUG-12:02 | 0.00 |
| September | 0.812714E+10 | 0.211433E+10 | 709.89 | 0.562756E+10 | 0.249957E+10 | 0.00 | 1.00 | 14-SEP-16:52 | 0.00 | 14-SEP-16:03 | 12409.00 | 15-SEP-20:52 | 8303.14 | 14-SEP-16:52 | 5840.97 | 15-SEP-20:55 | 2571.77 | 14-SEP-16:52 | 0.00 |
| October | 0.787020E+10 | 0.202799E+10 | 728.03 | 0.545395E+10 | 0.241625E+10 | 0.00 | 1.00 | 09-OCT-06:32 | 0.00 | 09-OCT-05:13 | 12419.80 | 23-OCT-08:62 | 8524.49 | 09-OCT-20:02 | 6143.23 | 23-OCT-08:05 | 2581.40 | 31-OCT-07:03 | 0.00 |
| November | 0.720435E+10 | 0.186433E+10 | 682.65 | 0.517597E+10 | 0.202838E+10 | 0.00 | 1.00 | 02-NOV-07:42 | 0.00 | 02-NOV-05:15 | 12264.13 | 26-NOV-10:42 | 8852.55 | 25-NOV-20:02 | 5214.43 | 26-NOV-10:45 | 2609.28 | 19-NOV-08:12 | 0.00 |
| December | 0.675330E+10 | 0.175337E+10 | 669.39 | 0.503625E+10 | 0.171705E+10 | 0.00 | 1.00 | 01-DEC-08:42 | 0.00 | 01-DEC-06:15 | 12335.06 | 24-DEC-09:12 | 9565.98 | 20-DEC-22:02 | 5598.54 | 24-DEC-09:13 | 2648.95 | 16-DEC-09:42 | 0.00 |
| Annual Sum or Average | 0.965314E+11 | 0.253403E+11 | 8456.91 | 0.695820E+11 | 0.269494E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.655831E+10 | 0.174052E+10 | 622.04 | 0.503625E+10 | 0.151217E+10 | 0.00 | 1.00 | 0.00 | 11731.39 | 8103.98 | 3533.91 | 2571.77 | 0.00 | ||||||
| Maximum of Months | 0.986025E+10 | 0.260850E+10 | 741.19 | 0.694020E+10 | 0.297825E+10 | 0.00 | 1.00 | 0.00 | 12419.80 | 9636.88 | 6143.23 | 2772.63 | 0.00 |
Report: DXReportMonthly
For: SPLIT MS1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.845216E+10 | 0.220894E+10 | 681.16 | 0.673528E+10 | 0.171688E+10 | 0.00 | 1.00 | 01-JAN-08:22 | 0.00 | 01-JAN-06:53 | 12212.09 | 08-JAN-10:12 | 9745.48 | 23-JAN-22:52 | 4937.97 | 08-JAN-10:15 | 2751.97 | 31-JAN-10:52 | 0.00 |
| February | 0.781788E+10 | 0.206916E+10 | 626.83 | 0.620555E+10 | 0.161233E+10 | 0.00 | 1.00 | 01-FEB-08:22 | 0.00 | 01-FEB-06:13 | 12112.67 | 10-FEB-08:32 | 9513.81 | 21-FEB-11:02 | 4393.85 | 10-FEB-08:33 | 2758.96 | 23-FEB-10:52 | 0.00 |
| March | 0.846780E+10 | 0.226312E+10 | 737.08 | 0.649311E+10 | 0.197469E+10 | 0.00 | 1.00 | 02-MAR-07:42 | 0.00 | 02-MAR-06:15 | 12218.05 | 15-MAR-07:22 | 8486.94 | 03-MAR-08:62 | 5020.05 | 15-MAR-07:23 | 2623.32 | 03-MAR-08:62 | 0.00 |
| April | 0.846036E+10 | 0.226718E+10 | 719.00 | 0.607414E+10 | 0.238622E+10 | 0.00 | 1.00 | 14-APR-16:52 | 0.00 | 14-APR-15:53 | 11721.44 | 14-APR-16:52 | 8372.08 | 14-APR-16:52 | 3502.62 | 14-APR-16:53 | 2732.38 | 14-APR-16:52 | 0.00 |
| May | 0.919132E+10 | 0.244081E+10 | 740.61 | 0.625612E+10 | 0.293519E+10 | 0.00 | 1.00 | 10-MAY-21:02 | 0.00 | 10-MAY-19:53 | 12142.53 | 31-MAY-21:42 | 7991.16 | 10-MAY-21:02 | 4557.22 | 31-MAY-21:43 | 2625.61 | 21-MAY-14:02 | 0.00 |
| June | 0.888452E+10 | 0.235489E+10 | 711.75 | 0.604696E+10 | 0.283757E+10 | 0.00 | 1.00 | 21-JUN-07:12 | 0.00 | 21-JUN-05:13 | 12290.85 | 25-JUN-21:42 | 8355.77 | 24-JUN-19:52 | 5283.10 | 25-JUN-21:45 | 2655.81 | 30-JUN-13:52 | 0.00 |
| July | 0.793303E+10 | 0.207078E+10 | 732.83 | 0.575564E+10 | 0.217739E+10 | 0.00 | 1.00 | 03-JUL-14:22 | 0.00 | 03-JUL-13:02 | 12170.99 | 19-JUL-21:52 | 8195.55 | 19-JUL-20:22 | 4717.16 | 13-JUL-06:53 | 2622.22 | 29-JUL-06:42 | 0.00 |
| August | 0.844677E+10 | 0.219178E+10 | 732.67 | 0.568333E+10 | 0.276344E+10 | 0.00 | 1.00 | 04-AUG-13:52 | 0.00 | 04-AUG-13:03 | 12466.76 | 20-AUG-13:12 | 8114.99 | 21-AUG-12:02 | 6178.30 | 20-AUG-13:15 | 2662.37 | 21-AUG-12:02 | 0.00 |
| September | 0.828527E+10 | 0.215676E+10 | 710.42 | 0.575835E+10 | 0.252692E+10 | 0.00 | 1.00 | 14-SEP-16:52 | 0.00 | 14-SEP-16:03 | 12404.65 | 15-SEP-20:52 | 8366.80 | 14-SEP-16:52 | 5760.29 | 15-SEP-20:55 | 2576.74 | 14-SEP-16:52 | 0.00 |
| October | 0.851293E+10 | 0.219444E+10 | 728.86 | 0.602198E+10 | 0.249095E+10 | 0.00 | 1.00 | 09-OCT-06:32 | 0.00 | 09-OCT-05:13 | 12411.00 | 23-OCT-07:52 | 8743.00 | 09-OCT-19:42 | 5900.30 | 23-OCT-07:53 | 2586.63 | 31-OCT-07:03 | 0.00 |
| November | 0.839918E+10 | 0.217142E+10 | 686.28 | 0.625811E+10 | 0.214106E+10 | 0.00 | 1.00 | 02-NOV-07:32 | 0.00 | 02-NOV-05:15 | 12217.52 | 26-NOV-10:02 | 9144.17 | 24-NOV-22:02 | 4930.46 | 02-NOV-07:33 | 2614.45 | 19-NOV-08:12 | 0.00 |
| December | 0.845687E+10 | 0.218902E+10 | 678.11 | 0.659127E+10 | 0.186560E+10 | 0.00 | 1.00 | 01-DEC-08:42 | 0.00 | 01-DEC-06:15 | 12298.04 | 20-DEC-08:32 | 9992.52 | 20-DEC-21:32 | 5228.38 | 20-DEC-08:35 | 2653.26 | 16-DEC-09:42 | 0.00 |
| Annual Sum or Average | 0.101308E+12 | 0.265783E+11 | 8485.60 | 0.738799E+11 | 0.274282E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.781788E+10 | 0.206916E+10 | 626.83 | 0.568333E+10 | 0.161233E+10 | 0.00 | 1.00 | 0.00 | 11721.44 | 7991.16 | 3502.62 | 2576.74 | 0.00 | ||||||
| Maximum of Months | 0.919132E+10 | 0.244081E+10 | 740.61 | 0.673528E+10 | 0.293519E+10 | 0.00 | 1.00 | 0.00 | 12466.76 | 9992.52 | 6178.30 | 2758.96 | 0.00 |
Report: DXReportMonthly
For: SPLIT MS2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.845519E+10 | 0.220957E+10 | 681.35 | 0.673773E+10 | 0.171747E+10 | 0.00 | 1.00 | 01-JAN-08:22 | 0.00 | 01-JAN-06:53 | 12196.51 | 08-JAN-10:12 | 9734.39 | 23-JAN-22:52 | 4928.66 | 08-JAN-10:15 | 2748.54 | 31-JAN-10:52 | 0.00 |
| February | 0.782095E+10 | 0.206982E+10 | 627.14 | 0.620816E+10 | 0.161280E+10 | 0.00 | 1.00 | 01-FEB-08:22 | 0.00 | 01-FEB-06:13 | 12098.60 | 10-FEB-08:32 | 9504.76 | 21-FEB-11:02 | 4388.09 | 10-FEB-08:33 | 2755.17 | 23-FEB-10:52 | 0.00 |
| March | 0.846703E+10 | 0.226288E+10 | 737.08 | 0.649220E+10 | 0.197483E+10 | 0.00 | 1.00 | 02-MAR-07:42 | 0.00 | 02-MAR-06:15 | 12203.30 | 15-MAR-07:22 | 8476.86 | 03-MAR-08:62 | 5012.74 | 15-MAR-07:23 | 2620.19 | 03-MAR-08:62 | 0.00 |
| April | 0.846134E+10 | 0.226739E+10 | 719.00 | 0.607481E+10 | 0.238653E+10 | 0.00 | 1.00 | 14-APR-16:52 | 0.00 | 14-APR-15:53 | 11706.98 | 14-APR-16:52 | 8360.90 | 14-APR-16:52 | 3498.86 | 14-APR-16:53 | 2729.08 | 14-APR-16:52 | 0.00 |
| May | 0.919343E+10 | 0.244128E+10 | 740.61 | 0.625779E+10 | 0.293564E+10 | 0.00 | 1.00 | 10-MAY-21:02 | 0.00 | 10-MAY-19:53 | 12128.18 | 31-MAY-21:42 | 7976.42 | 10-MAY-21:02 | 4554.94 | 31-MAY-21:43 | 2622.46 | 21-MAY-14:02 | 0.00 |
| June | 0.888712E+10 | 0.235549E+10 | 711.75 | 0.604905E+10 | 0.283807E+10 | 0.00 | 1.00 | 21-JUN-07:12 | 0.00 | 21-JUN-05:13 | 12276.33 | 25-JUN-21:42 | 8345.51 | 24-JUN-19:52 | 5280.38 | 25-JUN-21:45 | 2652.58 | 30-JUN-13:52 | 0.00 |
| July | 0.793484E+10 | 0.207118E+10 | 732.83 | 0.575701E+10 | 0.217783E+10 | 0.00 | 1.00 | 03-JUL-14:22 | 0.00 | 03-JUL-13:02 | 12156.45 | 19-JUL-21:52 | 8179.07 | 19-JUL-20:22 | 4710.30 | 13-JUL-06:53 | 2619.07 | 29-JUL-06:42 | 0.00 |
| August | 0.844955E+10 | 0.219244E+10 | 732.67 | 0.568554E+10 | 0.276401E+10 | 0.00 | 1.00 | 04-AUG-13:52 | 0.00 | 04-AUG-13:03 | 12451.75 | 20-AUG-13:12 | 8108.94 | 21-AUG-12:02 | 6169.96 | 20-AUG-13:15 | 2659.17 | 21-AUG-12:02 | 0.00 |
| September | 0.828815E+10 | 0.215743E+10 | 710.47 | 0.576070E+10 | 0.252745E+10 | 0.00 | 1.00 | 14-SEP-16:52 | 0.00 | 14-SEP-16:03 | 12389.84 | 15-SEP-20:52 | 8357.80 | 14-SEP-16:52 | 5754.08 | 15-SEP-20:55 | 2573.65 | 14-SEP-16:52 | 0.00 |
| October | 0.851383E+10 | 0.219459E+10 | 728.86 | 0.602255E+10 | 0.249128E+10 | 0.00 | 1.00 | 09-OCT-06:32 | 0.00 | 09-OCT-05:13 | 12396.10 | 23-OCT-07:52 | 8731.76 | 09-OCT-19:42 | 5893.51 | 23-OCT-07:53 | 2583.53 | 31-OCT-07:03 | 0.00 |
| November | 0.840103E+10 | 0.217177E+10 | 686.28 | 0.625954E+10 | 0.214149E+10 | 0.00 | 1.00 | 02-NOV-07:32 | 0.00 | 02-NOV-05:15 | 12202.49 | 26-NOV-10:02 | 9132.08 | 24-NOV-22:02 | 4923.12 | 02-NOV-07:33 | 2611.32 | 19-NOV-08:12 | 0.00 |
| December | 0.845934E+10 | 0.218954E+10 | 678.25 | 0.659352E+10 | 0.186582E+10 | 0.00 | 1.00 | 01-DEC-08:42 | 0.00 | 01-DEC-06:15 | 12267.71 | 20-DEC-08:32 | 9979.23 | 20-DEC-21:32 | 5154.25 | 20-DEC-08:35 | 2650.07 | 16-DEC-09:42 | 0.00 |
| Annual Sum or Average | 0.101332E+12 | 0.265834E+11 | 8486.30 | 0.738986E+11 | 0.274332E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.782095E+10 | 0.206982E+10 | 627.14 | 0.568554E+10 | 0.161280E+10 | 0.00 | 1.00 | 0.00 | 11706.98 | 7976.42 | 3498.86 | 2573.65 | 0.00 | ||||||
| Maximum of Months | 0.919343E+10 | 0.244128E+10 | 740.61 | 0.673773E+10 | 0.293564E+10 | 0.00 | 1.00 | 0.00 | 12451.75 | 9979.23 | 6169.96 | 2755.17 | 0.00 |
Report: DXReportMonthly
For: SPLIT TSW HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.508891E+10 | 0.133599E+10 | 682.89 | 0.416891E+10 | 0.920001E+09 | 0.00 | 1.00 | 01-JAN-08:22 | 0.00 | 01-JAN-06:53 | 7639.90 | 07-JAN-08:32 | 6124.19 | 23-JAN-22:52 | 3094.26 | 07-JAN-08:33 | 1715.50 | 31-JAN-10:52 | 0.00 |
| February | 0.484546E+10 | 0.128806E+10 | 630.25 | 0.396533E+10 | 0.880131E+09 | 0.00 | 1.00 | 01-FEB-08:22 | 0.00 | 01-FEB-06:13 | 7602.18 | 10-FEB-08:32 | 6384.51 | 21-FEB-10:42 | 2936.04 | 10-FEB-08:33 | 1718.82 | 23-FEB-10:52 | 0.00 |
| March | 0.556187E+10 | 0.148970E+10 | 737.08 | 0.442853E+10 | 0.113334E+10 | 0.00 | 1.00 | 02-MAR-07:42 | 0.00 | 02-MAR-06:15 | 7687.87 | 15-MAR-07:22 | 5221.88 | 03-MAR-08:62 | 3391.04 | 15-MAR-07:23 | 1635.84 | 03-MAR-08:62 | 0.00 |
| April | 0.564793E+10 | 0.151737E+10 | 719.22 | 0.427300E+10 | 0.137493E+10 | 0.00 | 1.00 | 14-APR-16:52 | 0.00 | 14-APR-15:53 | 7304.29 | 14-APR-16:52 | 5395.99 | 14-APR-16:52 | 2037.26 | 14-APR-16:53 | 1702.77 | 14-APR-16:52 | 0.00 |
| May | 0.596808E+10 | 0.159237E+10 | 741.06 | 0.427544E+10 | 0.169265E+10 | 0.00 | 1.00 | 10-MAY-21:02 | 0.00 | 10-MAY-19:53 | 7546.83 | 31-MAY-21:42 | 5270.83 | 10-MAY-21:02 | 2692.71 | 31-MAY-21:43 | 1636.31 | 21-MAY-14:02 | 0.00 |
| June | 0.582794E+10 | 0.155142E+10 | 712.08 | 0.418531E+10 | 0.164263E+10 | 0.00 | 1.00 | 21-JUN-07:12 | 0.00 | 21-JUN-05:13 | 7649.12 | 27-JUN-07:12 | 5568.97 | 25-JUN-19:52 | 3247.86 | 27-JUN-07:13 | 1654.93 | 30-JUN-13:52 | 0.00 |
| July | 0.500680E+10 | 0.131367E+10 | 733.31 | 0.378868E+10 | 0.121812E+10 | 0.00 | 1.00 | 03-JUL-14:02 | 0.00 | 03-JUL-13:02 | 7625.58 | 22-JUL-08:62 | 5625.36 | 03-JUL-14:02 | 3089.75 | 13-JUL-06:53 | 1634.19 | 29-JUL-06:42 | 0.00 |
| August | 0.532840E+10 | 0.138913E+10 | 733.56 | 0.374177E+10 | 0.158662E+10 | 0.00 | 1.00 | 04-AUG-13:52 | 0.00 | 04-AUG-13:03 | 7777.03 | 20-AUG-13:12 | 5284.31 | 21-AUG-12:02 | 3784.50 | 20-AUG-13:13 | 1657.84 | 21-AUG-12:02 | 0.00 |
| September | 0.520736E+10 | 0.136271E+10 | 710.78 | 0.379482E+10 | 0.141255E+10 | 0.00 | 1.00 | 14-SEP-16:52 | 0.00 | 14-SEP-16:03 | 7701.78 | 18-SEP-08:32 | 5341.24 | 14-SEP-16:52 | 3361.48 | 18-SEP-08:33 | 1605.85 | 14-SEP-16:52 | 0.00 |
| October | 0.515451E+10 | 0.133538E+10 | 729.28 | 0.378375E+10 | 0.137076E+10 | 0.00 | 1.00 | 09-OCT-06:32 | 0.00 | 09-OCT-05:13 | 7798.71 | 23-OCT-07:52 | 5627.11 | 09-OCT-19:42 | 3828.59 | 23-OCT-07:53 | 1610.85 | 31-OCT-07:03 | 0.00 |
| November | 0.500823E+10 | 0.130154E+10 | 687.40 | 0.385289E+10 | 0.115534E+10 | 0.00 | 1.00 | 02-NOV-07:32 | 0.00 | 02-NOV-05:15 | 7662.71 | 02-NOV-07:32 | 5792.46 | 25-NOV-19:52 | 3233.58 | 02-NOV-07:33 | 1629.36 | 19-NOV-08:13 | 0.00 |
| December | 0.497484E+10 | 0.129512E+10 | 680.78 | 0.398898E+10 | 0.985860E+09 | 0.00 | 1.00 | 01-DEC-08:42 | 0.00 | 01-DEC-06:15 | 7717.06 | 20-DEC-08:32 | 6248.71 | 20-DEC-21:32 | 3399.47 | 20-DEC-08:33 | 1653.95 | 16-DEC-09:42 | 0.00 |
| Annual Sum or Average | 0.636203E+11 | 0.167725E+11 | 8497.68 | 0.482474E+11 | 0.153729E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.484546E+10 | 0.128806E+10 | 630.25 | 0.374177E+10 | 0.880131E+09 | 0.00 | 1.00 | 0.00 | 7304.29 | 5221.88 | 2037.26 | 1605.85 | 0.00 | ||||||
| Maximum of Months | 0.596808E+10 | 0.159237E+10 | 741.06 | 0.442853E+10 | 0.169265E+10 | 0.00 | 1.00 | 0.00 | 7798.71 | 6384.51 | 3828.59 | 1718.82 | 0.00 |
Report: DXReportMonthly
For: SPLIT TNW HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.421829E+10 | 0.111534E+10 | 670.15 | 0.335217E+10 | 0.866125E+09 | 0.00 | 1.00 | 01-JAN-08:22 | 0.00 | 01-JAN-06:53 | 7741.58 | 27-JAN-08:42 | 6136.16 | 23-JAN-22:52 | 3280.70 | 27-JAN-08:43 | 1740.68 | 31-JAN-10:52 | 0.00 |
| February | 0.420973E+10 | 0.112538E+10 | 624.33 | 0.336204E+10 | 0.847688E+09 | 0.00 | 1.00 | 01-FEB-09:12 | 0.00 | 01-FEB-06:13 | 7704.71 | 10-FEB-08:42 | 5840.70 | 21-FEB-11:12 | 3100.57 | 10-FEB-08:43 | 1747.99 | 21-FEB-11:12 | 0.00 |
| March | 0.526529E+10 | 0.141336E+10 | 736.92 | 0.414271E+10 | 0.112258E+10 | 0.00 | 1.00 | 02-MAR-07:42 | 0.00 | 02-MAR-06:15 | 7777.14 | 15-MAR-07:22 | 5253.64 | 03-MAR-08:62 | 3492.21 | 15-MAR-07:23 | 1652.52 | 03-MAR-08:62 | 0.00 |
| April | 0.570301E+10 | 0.153251E+10 | 719.22 | 0.432275E+10 | 0.138027E+10 | 0.00 | 1.00 | 14-APR-16:52 | 0.00 | 14-APR-15:53 | 7392.75 | 14-APR-16:52 | 5402.06 | 14-APR-16:52 | 2116.88 | 14-APR-16:53 | 1720.89 | 14-APR-16:52 | 0.00 |
| May | 0.625981E+10 | 0.166878E+10 | 741.06 | 0.454301E+10 | 0.171680E+10 | 0.00 | 1.00 | 10-MAY-21:02 | 0.00 | 10-MAY-19:53 | 7589.70 | 31-MAY-21:42 | 5362.17 | 10-MAY-21:02 | 2586.06 | 31-MAY-21:43 | 1652.83 | 21-MAY-14:02 | 0.00 |
| June | 0.633345E+10 | 0.168257E+10 | 712.72 | 0.465154E+10 | 0.168191E+10 | 0.00 | 1.00 | 21-JUN-07:12 | 0.00 | 21-JUN-05:13 | 7723.27 | 27-JUN-07:12 | 5555.73 | 25-JUN-19:52 | 3247.03 | 27-JUN-07:13 | 1671.40 | 30-JUN-13:52 | 0.00 |
| July | 0.529969E+10 | 0.138915E+10 | 734.58 | 0.406071E+10 | 0.123898E+10 | 0.00 | 1.00 | 03-JUL-14:02 | 0.00 | 03-JUL-13:02 | 7694.94 | 22-JUL-08:62 | 5793.95 | 19-JUL-19:52 | 3081.64 | 22-JUL-08:03 | 1650.81 | 29-JUL-06:42 | 0.00 |
| August | 0.550336E+10 | 0.143450E+10 | 733.75 | 0.389714E+10 | 0.160623E+10 | 0.00 | 1.00 | 04-AUG-13:52 | 0.00 | 04-AUG-13:03 | 7863.09 | 20-AUG-13:12 | 5333.17 | 21-AUG-12:02 | 3840.43 | 20-AUG-13:13 | 1674.70 | 21-AUG-12:02 | 0.00 |
| September | 0.513225E+10 | 0.134423E+10 | 710.86 | 0.372326E+10 | 0.140899E+10 | 0.00 | 1.00 | 14-SEP-16:52 | 0.00 | 14-SEP-16:03 | 7790.99 | 18-SEP-08:32 | 5346.62 | 14-SEP-16:52 | 3446.97 | 18-SEP-08:33 | 1622.22 | 14-SEP-16:52 | 0.00 |
| October | 0.483780E+10 | 0.125547E+10 | 728.64 | 0.348869E+10 | 0.134911E+10 | 0.00 | 1.00 | 09-OCT-06:32 | 0.00 | 09-OCT-05:13 | 7886.62 | 23-OCT-08:62 | 5567.79 | 09-OCT-20:02 | 3927.09 | 23-OCT-08:03 | 1627.33 | 31-OCT-07:03 | 0.00 |
| November | 0.440577E+10 | 0.114934E+10 | 683.72 | 0.328844E+10 | 0.111733E+10 | 0.00 | 1.00 | 02-NOV-07:42 | 0.00 | 02-NOV-05:15 | 7764.13 | 02-NOV-07:42 | 5712.84 | 25-NOV-20:02 | 3401.59 | 02-NOV-07:43 | 1645.93 | 19-NOV-08:13 | 0.00 |
| December | 0.410830E+10 | 0.107623E+10 | 672.21 | 0.317786E+10 | 0.930437E+09 | 0.00 | 1.00 | 01-DEC-08:42 | 0.00 | 01-DEC-06:15 | 7843.39 | 20-DEC-08:42 | 6177.93 | 20-DEC-22:02 | 3653.74 | 20-DEC-08:43 | 1671.10 | 16-DEC-09:42 | 0.00 |
| Annual Sum or Average | 0.612768E+11 | 0.161869E+11 | 8468.15 | 0.460103E+11 | 0.152664E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.410830E+10 | 0.107623E+10 | 624.33 | 0.317786E+10 | 0.847688E+09 | 0.00 | 1.00 | 0.00 | 7392.75 | 5253.64 | 2116.88 | 1622.22 | 0.00 | ||||||
| Maximum of Months | 0.633345E+10 | 0.168257E+10 | 741.06 | 0.465154E+10 | 0.171680E+10 | 0.00 | 1.00 | 0.00 | 7886.62 | 6177.93 | 3927.09 | 1747.99 | 0.00 |
Report: DXReportMonthly
For: SPLIT TSE HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.506327E+10 | 0.132216E+10 | 684.99 | 0.413990E+10 | 0.923371E+09 | 0.00 | 1.00 | 01-JAN-08:22 | 0.00 | 01-JAN-06:53 | 7114.77 | 08-JAN-09:53 | 5953.29 | 31-JAN-10:32 | 2807.26 | 02-JAN-08:03 | 1582.37 | 31-JAN-10:52 | 0.00 |
| February | 0.484222E+10 | 0.127958E+10 | 631.42 | 0.395839E+10 | 0.883824E+09 | 0.00 | 1.00 | 01-FEB-08:22 | 0.00 | 01-FEB-06:13 | 6999.40 | 10-FEB-08:32 | 6284.93 | 21-FEB-10:42 | 2547.26 | 10-FEB-08:33 | 1585.94 | 23-FEB-10:52 | 0.00 |
| March | 0.552467E+10 | 0.147415E+10 | 737.72 | 0.439052E+10 | 0.113414E+10 | 0.00 | 1.00 | 02-MAR-07:42 | 0.00 | 02-MAR-06:15 | 7120.41 | 15-MAR-07:22 | 4872.58 | 03-MAR-08:62 | 3091.89 | 15-MAR-07:23 | 1513.52 | 03-MAR-08:62 | 0.00 |
| April | 0.564762E+10 | 0.151097E+10 | 719.19 | 0.427067E+10 | 0.137695E+10 | 0.00 | 1.00 | 14-APR-16:52 | 0.00 | 14-APR-15:53 | 6776.26 | 14-APR-16:52 | 4933.31 | 14-APR-16:52 | 1953.55 | 14-APR-16:53 | 1576.61 | 14-APR-16:52 | 0.00 |
| May | 0.599196E+10 | 0.159159E+10 | 741.28 | 0.429573E+10 | 0.169622E+10 | 0.00 | 1.00 | 10-MAY-21:02 | 0.00 | 10-MAY-19:53 | 7003.64 | 31-MAY-21:42 | 4809.94 | 10-MAY-21:02 | 2564.78 | 31-MAY-21:43 | 1514.10 | 21-MAY-14:02 | 0.00 |
| June | 0.586354E+10 | 0.155376E+10 | 712.58 | 0.421604E+10 | 0.164750E+10 | 0.00 | 1.00 | 21-JUN-07:12 | 0.00 | 21-JUN-05:13 | 7072.87 | 27-JUN-07:12 | 5000.04 | 30-JUN-13:52 | 2956.50 | 27-JUN-07:13 | 1530.80 | 30-JUN-13:52 | 0.00 |
| July | 0.502406E+10 | 0.131266E+10 | 734.03 | 0.380252E+10 | 0.122154E+10 | 0.00 | 1.00 | 03-JUL-14:02 | 0.00 | 03-JUL-13:02 | 7051.69 | 22-JUL-08:62 | 5240.92 | 03-JUL-14:02 | 2824.62 | 22-JUL-08:03 | 1512.15 | 29-JUL-06:43 | 0.00 |
| August | 0.536358E+10 | 0.139300E+10 | 733.53 | 0.377203E+10 | 0.159155E+10 | 0.00 | 1.00 | 04-AUG-13:52 | 0.00 | 04-AUG-13:03 | 7192.40 | 20-AUG-13:12 | 4978.35 | 21-AUG-12:02 | 3485.29 | 20-AUG-13:13 | 1533.22 | 21-AUG-12:02 | 0.00 |
| September | 0.523999E+10 | 0.136563E+10 | 710.81 | 0.382379E+10 | 0.141621E+10 | 0.00 | 1.00 | 14-SEP-16:52 | 0.00 | 14-SEP-16:03 | 7113.99 | 18-SEP-08:32 | 4934.19 | 14-SEP-16:52 | 3046.59 | 18-SEP-08:33 | 1485.94 | 14-SEP-16:52 | 0.00 |
| October | 0.515881E+10 | 0.133128E+10 | 730.03 | 0.378619E+10 | 0.137262E+10 | 0.00 | 1.00 | 09-OCT-06:32 | 0.00 | 09-OCT-05:13 | 7214.91 | 23-OCT-07:52 | 5174.62 | 09-OCT-19:42 | 3578.79 | 23-OCT-07:55 | 1490.59 | 31-OCT-07:03 | 0.00 |
| November | 0.501041E+10 | 0.129593E+10 | 688.33 | 0.385254E+10 | 0.115787E+10 | 0.00 | 1.00 | 02-NOV-07:32 | 0.00 | 02-NOV-05:15 | 7090.55 | 26-NOV-08:32 | 5364.40 | 25-NOV-09:43 | 2954.74 | 26-NOV-08:33 | 1507.68 | 19-NOV-08:13 | 0.00 |
| December | 0.496382E+10 | 0.128532E+10 | 682.47 | 0.397322E+10 | 0.990595E+09 | 0.00 | 1.00 | 01-DEC-08:42 | 0.00 | 01-DEC-06:15 | 7104.12 | 17-DEC-08:42 | 5768.31 | 20-DEC-21:32 | 3023.09 | 18-DEC-08:03 | 1533.45 | 24-DEC-09:55 | 0.00 |
| Annual Sum or Average | 0.636939E+11 | 0.167160E+11 | 8506.37 | 0.482816E+11 | 0.154124E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.484222E+10 | 0.127958E+10 | 631.42 | 0.377203E+10 | 0.883824E+09 | 0.00 | 1.00 | 0.00 | 6776.26 | 4809.94 | 1953.55 | 1485.94 | 0.00 | ||||||
| Maximum of Months | 0.599196E+10 | 0.159159E+10 | 741.28 | 0.439052E+10 | 0.169622E+10 | 0.00 | 1.00 | 0.00 | 7214.91 | 6284.93 | 3578.79 | 1585.94 | 0.00 |
Report: DXReportMonthly
For: SPLIT TNE HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.418620E+10 | 0.110200E+10 | 673.76 | 0.331675E+10 | 0.869453E+09 | 0.00 | 1.00 | 01-JAN-08:22 | 0.00 | 01-JAN-06:53 | 7139.49 | 08-JAN-08:42 | 5680.55 | 23-JAN-22:52 | 2912.00 | 27-JAN-08:43 | 1604.88 | 31-JAN-10:52 | 0.00 |
| February | 0.420509E+10 | 0.111833E+10 | 626.65 | 0.335269E+10 | 0.852399E+09 | 0.00 | 1.00 | 01-FEB-09:12 | 0.00 | 01-FEB-06:13 | 7106.47 | 10-FEB-08:42 | 6080.16 | 21-FEB-10:52 | 2733.66 | 10-FEB-08:43 | 1612.17 | 23-FEB-11:02 | 0.00 |
| March | 0.522933E+10 | 0.139896E+10 | 737.47 | 0.410555E+10 | 0.112379E+10 | 0.00 | 1.00 | 02-MAR-07:42 | 0.00 | 02-MAR-06:15 | 7203.56 | 15-MAR-07:22 | 4902.68 | 03-MAR-08:62 | 3185.17 | 15-MAR-07:23 | 1529.05 | 03-MAR-08:62 | 0.00 |
| April | 0.570288E+10 | 0.152612E+10 | 719.19 | 0.432068E+10 | 0.138220E+10 | 0.00 | 1.00 | 14-APR-16:52 | 0.00 | 14-APR-15:53 | 6859.46 | 14-APR-16:52 | 4941.60 | 14-APR-16:52 | 2028.17 | 14-APR-16:53 | 1593.49 | 14-APR-16:52 | 0.00 |
| May | 0.628340E+10 | 0.166715E+10 | 741.14 | 0.456348E+10 | 0.171992E+10 | 0.00 | 1.00 | 10-MAY-21:02 | 0.00 | 10-MAY-19:53 | 7051.32 | 31-MAY-21:42 | 4925.00 | 10-MAY-21:02 | 2498.32 | 31-MAY-21:43 | 1529.47 | 21-MAY-14:02 | 0.00 |
| June | 0.636848E+10 | 0.168333E+10 | 712.92 | 0.468249E+10 | 0.168599E+10 | 0.00 | 1.00 | 21-JUN-07:12 | 0.00 | 21-JUN-05:13 | 7137.71 | 27-JUN-07:12 | 5104.61 | 30-JUN-13:52 | 2955.00 | 27-JUN-07:13 | 1546.20 | 30-JUN-13:52 | 0.00 |
| July | 0.531678E+10 | 0.138749E+10 | 734.99 | 0.407473E+10 | 0.124205E+10 | 0.00 | 1.00 | 03-JUL-14:02 | 0.00 | 03-JUL-13:02 | 7115.71 | 22-JUL-08:62 | 5391.20 | 03-JUL-14:02 | 2820.41 | 22-JUL-08:03 | 1527.60 | 29-JUL-06:42 | 0.00 |
| August | 0.553875E+10 | 0.143800E+10 | 733.69 | 0.392782E+10 | 0.161093E+10 | 0.00 | 1.00 | 04-AUG-13:52 | 0.00 | 04-AUG-13:03 | 7260.51 | 20-AUG-13:12 | 5018.92 | 21-AUG-12:02 | 3487.32 | 20-AUG-13:13 | 1548.96 | 21-AUG-12:02 | 0.00 |
| September | 0.516564E+10 | 0.134760E+10 | 710.92 | 0.375287E+10 | 0.141277E+10 | 0.00 | 1.00 | 14-SEP-16:52 | 0.00 | 14-SEP-16:03 | 7196.89 | 18-SEP-08:32 | 4939.23 | 14-SEP-16:52 | 3125.98 | 18-SEP-08:33 | 1501.17 | 14-SEP-16:52 | 0.00 |
| October | 0.484336E+10 | 0.125256E+10 | 728.97 | 0.349194E+10 | 0.135143E+10 | 0.00 | 1.00 | 09-OCT-06:32 | 0.00 | 09-OCT-05:13 | 7295.91 | 23-OCT-08:62 | 5112.53 | 09-OCT-20:02 | 3661.91 | 23-OCT-08:05 | 1505.79 | 31-OCT-07:03 | 0.00 |
| November | 0.440997E+10 | 0.114577E+10 | 685.78 | 0.328907E+10 | 0.112090E+10 | 0.00 | 1.00 | 02-NOV-07:42 | 0.00 | 02-NOV-05:15 | 7166.98 | 26-NOV-08:52 | 5272.90 | 25-NOV-20:02 | 3002.44 | 02-NOV-07:43 | 1523.10 | 19-NOV-08:13 | 0.00 |
| December | 0.409231E+10 | 0.106744E+10 | 676.17 | 0.315676E+10 | 0.935549E+09 | 0.00 | 1.00 | 01-DEC-08:42 | 0.00 | 01-DEC-06:15 | 7233.88 | 20-DEC-08:42 | 5617.44 | 20-DEC-22:02 | 3217.58 | 20-DEC-08:42 | 1546.23 | 16-DEC-09:42 | 0.00 |
| Annual Sum or Average | 0.613422E+11 | 0.161347E+11 | 8481.66 | 0.460348E+11 | 0.153074E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.409231E+10 | 0.106744E+10 | 626.65 | 0.315676E+10 | 0.852399E+09 | 0.00 | 1.00 | 0.00 | 6859.46 | 4902.68 | 2028.17 | 1501.17 | 0.00 | ||||||
| Maximum of Months | 0.636848E+10 | 0.168333E+10 | 741.14 | 0.468249E+10 | 0.171992E+10 | 0.00 | 1.00 | 0.00 | 7295.91 | 6080.16 | 3661.91 | 1612.17 | 0.00 |
Report: DXReportMonthly
For: SPLIT TN1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.357288E+10 | 0.941774E+09 | 670.21 | 0.277583E+10 | 0.797051E+09 | 0.00 | 1.00 | 01-JAN-08:22 | 0.00 | 01-JAN-06:53 | 6647.34 | 27-JAN-08:42 | 5267.30 | 23-JAN-22:52 | 2772.90 | 27-JAN-08:43 | 1496.81 | 31-JAN-10:52 | 0.00 |
| February | 0.351675E+10 | 0.937722E+09 | 624.30 | 0.274404E+10 | 0.772709E+09 | 0.00 | 1.00 | 01-FEB-09:12 | 0.00 | 01-FEB-06:13 | 6616.96 | 10-FEB-08:42 | 4991.30 | 21-FEB-11:12 | 2623.59 | 10-FEB-08:43 | 1503.87 | 21-FEB-11:12 | 0.00 |
| March | 0.431648E+10 | 0.115826E+10 | 736.86 | 0.331826E+10 | 0.998225E+09 | 0.00 | 1.00 | 02-MAR-07:42 | 0.00 | 02-MAR-06:15 | 6676.05 | 15-MAR-07:22 | 4554.03 | 03-MAR-08:62 | 2924.44 | 15-MAR-07:23 | 1420.54 | 03-MAR-08:62 | 0.00 |
| April | 0.472939E+10 | 0.126994E+10 | 719.11 | 0.348840E+10 | 0.124099E+10 | 0.00 | 1.00 | 14-APR-16:52 | 0.00 | 14-APR-15:53 | 6381.14 | 14-APR-16:52 | 4556.31 | 14-APR-16:52 | 1918.54 | 14-APR-16:53 | 1480.85 | 14-APR-16:52 | 0.00 |
| May | 0.533091E+10 | 0.141830E+10 | 740.92 | 0.378155E+10 | 0.154936E+10 | 0.00 | 1.00 | 10-MAY-21:02 | 0.00 | 10-MAY-19:53 | 6544.24 | 31-MAY-21:42 | 4544.63 | 10-MAY-21:02 | 2276.72 | 31-MAY-21:43 | 1420.97 | 21-MAY-14:02 | 0.00 |
| June | 0.540281E+10 | 0.143294E+10 | 712.89 | 0.388362E+10 | 0.151919E+10 | 0.00 | 1.00 | 21-JUN-07:12 | 0.00 | 21-JUN-05:13 | 6631.19 | 27-JUN-07:12 | 4677.70 | 25-JUN-19:52 | 2742.19 | 27-JUN-07:13 | 1437.39 | 30-JUN-13:52 | 0.00 |
| July | 0.457840E+10 | 0.119689E+10 | 734.49 | 0.344081E+10 | 0.113759E+10 | 0.00 | 1.00 | 03-JUL-14:02 | 0.00 | 03-JUL-13:02 | 6604.85 | 22-JUL-08:62 | 4903.82 | 19-JUL-19:52 | 2590.55 | 22-JUL-08:03 | 1419.19 | 29-JUL-06:42 | 0.00 |
| August | 0.471850E+10 | 0.122717E+10 | 733.92 | 0.326945E+10 | 0.144906E+10 | 0.00 | 1.00 | 04-AUG-13:52 | 0.00 | 04-AUG-13:03 | 6751.58 | 20-AUG-13:12 | 4529.23 | 21-AUG-12:02 | 3297.07 | 20-AUG-13:15 | 1440.24 | 21-AUG-12:02 | 0.00 |
| September | 0.439877E+10 | 0.114848E+10 | 710.81 | 0.310745E+10 | 0.129133E+10 | 0.00 | 1.00 | 14-SEP-16:52 | 0.00 | 14-SEP-16:03 | 6692.56 | 18-SEP-08:32 | 4558.73 | 14-SEP-16:52 | 2928.85 | 18-SEP-08:33 | 1394.65 | 14-SEP-16:52 | 0.00 |
| October | 0.418779E+10 | 0.108306E+10 | 728.78 | 0.294695E+10 | 0.124084E+10 | 0.00 | 1.00 | 09-OCT-06:32 | 0.00 | 09-OCT-05:13 | 6758.39 | 23-OCT-08:62 | 4728.43 | 09-OCT-20:02 | 3318.41 | 23-OCT-08:05 | 1399.16 | 31-OCT-07:03 | 0.00 |
| November | 0.381023E+10 | 0.990141E+09 | 684.32 | 0.277554E+10 | 0.103469E+10 | 0.00 | 1.00 | 02-NOV-07:42 | 0.00 | 02-NOV-05:15 | 6666.01 | 02-NOV-07:42 | 4872.45 | 25-NOV-20:02 | 2869.37 | 02-NOV-07:43 | 1414.99 | 19-NOV-08:13 | 0.00 |
| December | 0.353500E+10 | 0.922191E+09 | 671.86 | 0.266901E+10 | 0.865992E+09 | 0.00 | 1.00 | 01-DEC-08:42 | 0.00 | 01-DEC-06:15 | 6732.51 | 20-DEC-08:42 | 5230.37 | 20-DEC-22:02 | 3116.54 | 20-DEC-08:45 | 1436.61 | 16-DEC-09:42 | 0.00 |
| Annual Sum or Average | 0.520979E+11 | 0.137269E+11 | 8468.46 | 0.382009E+11 | 0.138970E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.351675E+10 | 0.922191E+09 | 624.30 | 0.266901E+10 | 0.772709E+09 | 0.00 | 1.00 | 0.00 | 6381.14 | 4529.23 | 1918.54 | 1394.65 | 0.00 | ||||||
| Maximum of Months | 0.540281E+10 | 0.143294E+10 | 740.92 | 0.388362E+10 | 0.154936E+10 | 0.00 | 1.00 | 0.00 | 6758.39 | 5267.30 | 3318.41 | 1503.87 | 0.00 |
Report: DXReportMonthly
For: SPLIT TN2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.357541E+10 | 0.942301E+09 | 670.65 | 0.277782E+10 | 0.797592E+09 | 0.00 | 1.00 | 01-JAN-08:22 | 0.00 | 01-JAN-06:53 | 6625.99 | 27-JAN-08:42 | 5250.43 | 23-JAN-22:52 | 2762.75 | 27-JAN-08:43 | 1491.93 | 31-JAN-10:52 | 0.00 |
| February | 0.351922E+10 | 0.938229E+09 | 624.56 | 0.274601E+10 | 0.773211E+09 | 0.00 | 1.00 | 01-FEB-09:12 | 0.00 | 01-FEB-06:13 | 6595.86 | 10-FEB-08:42 | 4979.86 | 21-FEB-11:12 | 2613.36 | 10-FEB-08:43 | 1498.97 | 21-FEB-11:12 | 0.00 |
| March | 0.431609E+10 | 0.115806E+10 | 737.03 | 0.331766E+10 | 0.998437E+09 | 0.00 | 1.00 | 02-MAR-07:42 | 0.00 | 02-MAR-06:15 | 6655.12 | 15-MAR-07:22 | 4538.48 | 03-MAR-08:62 | 2914.54 | 15-MAR-07:23 | 1416.08 | 03-MAR-08:62 | 0.00 |
| April | 0.473006E+10 | 0.126997E+10 | 719.11 | 0.348879E+10 | 0.124127E+10 | 0.00 | 1.00 | 14-APR-16:52 | 0.00 | 14-APR-15:53 | 6361.13 | 14-APR-16:52 | 4539.96 | 14-APR-16:52 | 1914.09 | 14-APR-16:53 | 1476.20 | 14-APR-16:52 | 0.00 |
| May | 0.533225E+10 | 0.141844E+10 | 740.92 | 0.378253E+10 | 0.154972E+10 | 0.00 | 1.00 | 10-MAY-21:02 | 0.00 | 10-MAY-19:53 | 6524.44 | 31-MAY-21:42 | 4527.80 | 10-MAY-21:02 | 2273.11 | 31-MAY-21:43 | 1416.51 | 21-MAY-14:02 | 0.00 |
| June | 0.540457E+10 | 0.143317E+10 | 712.89 | 0.388499E+10 | 0.151957E+10 | 0.00 | 1.00 | 21-JUN-07:12 | 0.00 | 21-JUN-05:13 | 6610.17 | 27-JUN-07:12 | 4658.84 | 25-JUN-19:52 | 2733.34 | 27-JUN-07:13 | 1432.84 | 30-JUN-13:52 | 0.00 |
| July | 0.457964E+10 | 0.119704E+10 | 734.49 | 0.344168E+10 | 0.113797E+10 | 0.00 | 1.00 | 03-JUL-14:02 | 0.00 | 03-JUL-13:02 | 6584.01 | 22-JUL-08:62 | 4884.02 | 19-JUL-19:52 | 2582.52 | 22-JUL-08:03 | 1414.74 | 29-JUL-06:42 | 0.00 |
| August | 0.472033E+10 | 0.122750E+10 | 733.94 | 0.327084E+10 | 0.144948E+10 | 0.00 | 1.00 | 04-AUG-13:52 | 0.00 | 04-AUG-13:03 | 6729.98 | 20-AUG-13:12 | 4517.13 | 21-AUG-12:02 | 3285.76 | 20-AUG-13:15 | 1435.70 | 21-AUG-12:02 | 0.00 |
| September | 0.440057E+10 | 0.114881E+10 | 710.81 | 0.310884E+10 | 0.129172E+10 | 0.00 | 1.00 | 14-SEP-16:52 | 0.00 | 14-SEP-16:03 | 6671.13 | 18-SEP-08:32 | 4544.56 | 14-SEP-16:52 | 2918.26 | 18-SEP-08:33 | 1390.27 | 14-SEP-16:52 | 0.00 |
| October | 0.418856E+10 | 0.108315E+10 | 728.78 | 0.294740E+10 | 0.124116E+10 | 0.00 | 1.00 | 09-OCT-06:32 | 0.00 | 09-OCT-05:13 | 6737.11 | 23-OCT-08:62 | 4711.92 | 09-OCT-20:02 | 3307.93 | 23-OCT-08:05 | 1394.77 | 31-OCT-07:03 | 0.00 |
| November | 0.381156E+10 | 0.990364E+09 | 684.37 | 0.277646E+10 | 0.103509E+10 | 0.00 | 1.00 | 02-NOV-07:42 | 0.00 | 02-NOV-05:15 | 6644.91 | 02-NOV-07:42 | 4856.57 | 25-NOV-20:02 | 2857.97 | 02-NOV-07:43 | 1410.55 | 19-NOV-08:13 | 0.00 |
| December | 0.353730E+10 | 0.922665E+09 | 672.25 | 0.267073E+10 | 0.866577E+09 | 0.00 | 1.00 | 01-DEC-08:42 | 0.00 | 01-DEC-06:15 | 6711.81 | 20-DEC-08:42 | 5211.95 | 20-DEC-22:02 | 3088.85 | 20-DEC-08:45 | 1432.10 | 16-DEC-09:42 | 0.00 |
| Annual Sum or Average | 0.521156E+11 | 0.137297E+11 | 8469.79 | 0.382138E+11 | 0.139018E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.351922E+10 | 0.922665E+09 | 624.56 | 0.267073E+10 | 0.773211E+09 | 0.00 | 1.00 | 0.00 | 6361.13 | 4517.13 | 1914.09 | 1390.27 | 0.00 | ||||||
| Maximum of Months | 0.540457E+10 | 0.143317E+10 | 740.92 | 0.388499E+10 | 0.154972E+10 | 0.00 | 1.00 | 0.00 | 6737.11 | 5250.43 | 3307.93 | 1498.97 | 0.00 |
Report: DXReportMonthly
For: SPLIT TS1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.445790E+10 | 0.116719E+10 | 684.11 | 0.360115E+10 | 0.856752E+09 | 0.00 | 1.00 | 01-JAN-08:22 | 0.00 | 01-JAN-06:53 | 6553.99 | 08-JAN-08:32 | 5260.12 | 23-JAN-22:52 | 2586.48 | 08-JAN-10:15 | 1474.69 | 31-JAN-10:52 | 0.00 |
| February | 0.416405E+10 | 0.110456E+10 | 630.50 | 0.335353E+10 | 0.810523E+09 | 0.00 | 1.00 | 01-FEB-08:22 | 0.00 | 01-FEB-06:13 | 6520.26 | 10-FEB-08:32 | 5417.35 | 21-FEB-10:42 | 2445.61 | 10-FEB-08:33 | 1477.74 | 23-FEB-10:52 | 0.00 |
| March | 0.461930E+10 | 0.123724E+10 | 737.17 | 0.360689E+10 | 0.101241E+10 | 0.00 | 1.00 | 02-MAR-07:42 | 0.00 | 02-MAR-06:15 | 6598.37 | 15-MAR-07:22 | 4525.57 | 03-MAR-08:62 | 2835.01 | 15-MAR-07:23 | 1406.11 | 03-MAR-08:62 | 0.00 |
| April | 0.467422E+10 | 0.125488E+10 | 719.11 | 0.343850E+10 | 0.123572E+10 | 0.00 | 1.00 | 14-APR-16:52 | 0.00 | 14-APR-15:53 | 6303.47 | 14-APR-16:52 | 4543.36 | 14-APR-16:52 | 1853.60 | 14-APR-16:53 | 1465.17 | 14-APR-16:52 | 0.00 |
| May | 0.503393E+10 | 0.134015E+10 | 741.08 | 0.351121E+10 | 0.152271E+10 | 0.00 | 1.00 | 10-MAY-21:02 | 0.00 | 10-MAY-19:53 | 6510.68 | 31-MAY-21:42 | 4457.45 | 10-MAY-21:02 | 2395.74 | 31-MAY-21:43 | 1406.69 | 21-MAY-14:02 | 0.00 |
| June | 0.488789E+10 | 0.129855E+10 | 712.00 | 0.341254E+10 | 0.147534E+10 | 0.00 | 1.00 | 21-JUN-07:12 | 0.00 | 21-JUN-05:13 | 6568.60 | 27-JUN-07:12 | 4550.90 | 24-JUN-19:52 | 2748.73 | 27-JUN-07:13 | 1423.10 | 30-JUN-13:52 | 0.00 |
| July | 0.427983E+10 | 0.111974E+10 | 733.34 | 0.316541E+10 | 0.111443E+10 | 0.00 | 1.00 | 03-JUL-14:22 | 0.00 | 03-JUL-13:02 | 6544.94 | 22-JUL-08:62 | 4607.56 | 19-JUL-20:22 | 2618.80 | 13-JUL-06:53 | 1404.84 | 29-JUL-06:42 | 0.00 |
| August | 0.454014E+10 | 0.118085E+10 | 733.72 | 0.311222E+10 | 0.142793E+10 | 0.00 | 1.00 | 04-AUG-13:52 | 0.00 | 04-AUG-13:03 | 6676.24 | 20-AUG-13:12 | 4486.22 | 21-AUG-12:02 | 3247.25 | 20-AUG-13:15 | 1425.67 | 21-AUG-12:02 | 0.00 |
| September | 0.447540E+10 | 0.116771E+10 | 710.69 | 0.317932E+10 | 0.129608E+10 | 0.00 | 1.00 | 14-SEP-16:52 | 0.00 | 14-SEP-16:03 | 6615.20 | 18-SEP-08:32 | 4554.30 | 14-SEP-16:52 | 2854.52 | 18-SEP-08:33 | 1380.52 | 14-SEP-16:52 | 0.00 |
| October | 0.451173E+10 | 0.116533E+10 | 729.72 | 0.324503E+10 | 0.126670E+10 | 0.00 | 1.00 | 09-OCT-06:32 | 0.00 | 09-OCT-05:13 | 6682.39 | 23-OCT-07:52 | 4781.30 | 09-OCT-19:42 | 3234.97 | 23-OCT-07:55 | 1385.03 | 31-OCT-07:03 | 0.00 |
| November | 0.442415E+10 | 0.114594E+10 | 688.46 | 0.334572E+10 | 0.107843E+10 | 0.00 | 1.00 | 02-NOV-07:32 | 0.00 | 02-NOV-05:15 | 6569.98 | 02-NOV-07:32 | 4926.82 | 24-NOV-22:02 | 2692.93 | 02-NOV-07:33 | 1400.67 | 19-NOV-08:13 | 0.00 |
| December | 0.441758E+10 | 0.114597E+10 | 682.06 | 0.348990E+10 | 0.927675E+09 | 0.00 | 1.00 | 01-DEC-08:42 | 0.00 | 01-DEC-06:15 | 6609.98 | 24-DEC-08:22 | 5376.55 | 20-DEC-21:32 | 2817.54 | 24-DEC-08:23 | 1421.69 | 16-DEC-09:42 | 0.00 |
| Annual Sum or Average | 0.544861E+11 | 0.143281E+11 | 8501.97 | 0.404614E+11 | 0.140247E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.416405E+10 | 0.110456E+10 | 630.50 | 0.311222E+10 | 0.810523E+09 | 0.00 | 1.00 | 0.00 | 6303.47 | 4457.45 | 1853.60 | 1380.52 | 0.00 | ||||||
| Maximum of Months | 0.503393E+10 | 0.134015E+10 | 741.08 | 0.360689E+10 | 0.152271E+10 | 0.00 | 1.00 | 0.00 | 6682.39 | 5417.35 | 3247.25 | 1477.74 | 0.00 |
Report: DXReportMonthly
For: SPLIT TS2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.445788E+10 | 0.116683E+10 | 684.09 | 0.360238E+10 | 0.855495E+09 | 0.00 | 1.00 | 01-JAN-08:22 | 0.00 | 01-JAN-06:53 | 6533.45 | 08-JAN-08:32 | 5247.66 | 23-JAN-22:52 | 2571.19 | 08-JAN-10:15 | 1470.00 | 31-JAN-10:52 | 0.00 |
| February | 0.416428E+10 | 0.110429E+10 | 630.47 | 0.335495E+10 | 0.809330E+09 | 0.00 | 1.00 | 01-FEB-08:22 | 0.00 | 01-FEB-06:13 | 6499.94 | 10-FEB-08:32 | 5416.38 | 21-FEB-10:42 | 2434.37 | 10-FEB-08:33 | 1473.04 | 23-FEB-10:52 | 0.00 |
| March | 0.461685E+10 | 0.123635E+10 | 737.17 | 0.360606E+10 | 0.101079E+10 | 0.00 | 1.00 | 02-MAR-07:42 | 0.00 | 02-MAR-06:15 | 6578.16 | 15-MAR-07:22 | 4515.63 | 03-MAR-08:62 | 2823.29 | 15-MAR-07:23 | 1401.71 | 03-MAR-08:62 | 0.00 |
| April | 0.467303E+10 | 0.125430E+10 | 719.11 | 0.343871E+10 | 0.123432E+10 | 0.00 | 1.00 | 14-APR-16:52 | 0.00 | 14-APR-15:53 | 6284.88 | 14-APR-16:52 | 4530.01 | 14-APR-16:52 | 1848.24 | 14-APR-16:53 | 1460.65 | 14-APR-16:52 | 0.00 |
| May | 0.503348E+10 | 0.133974E+10 | 741.08 | 0.351207E+10 | 0.152141E+10 | 0.00 | 1.00 | 10-MAY-21:02 | 0.00 | 10-MAY-19:53 | 6491.71 | 31-MAY-21:42 | 4444.10 | 10-MAY-21:02 | 2390.18 | 31-MAY-21:43 | 1402.28 | 21-MAY-14:02 | 0.00 |
| June | 0.488791E+10 | 0.129827E+10 | 712.00 | 0.341379E+10 | 0.147412E+10 | 0.00 | 1.00 | 21-JUN-07:12 | 0.00 | 21-JUN-05:13 | 6548.65 | 27-JUN-07:12 | 4538.83 | 24-JUN-19:52 | 2737.62 | 27-JUN-07:13 | 1418.63 | 30-JUN-13:52 | 0.00 |
| July | 0.427927E+10 | 0.111935E+10 | 733.51 | 0.316612E+10 | 0.111315E+10 | 0.00 | 1.00 | 03-JUL-14:22 | 0.00 | 03-JUL-13:02 | 6524.84 | 22-JUL-08:62 | 4591.65 | 19-JUL-20:22 | 2607.22 | 13-JUL-06:53 | 1400.43 | 29-JUL-06:42 | 0.00 |
| August | 0.454020E+10 | 0.118063E+10 | 733.72 | 0.311346E+10 | 0.142674E+10 | 0.00 | 1.00 | 04-AUG-13:52 | 0.00 | 04-AUG-13:03 | 6655.18 | 20-AUG-13:12 | 4478.00 | 21-AUG-12:02 | 3234.68 | 20-AUG-13:15 | 1421.19 | 21-AUG-12:02 | 0.00 |
| September | 0.447545E+10 | 0.116746E+10 | 710.69 | 0.318052E+10 | 0.129492E+10 | 0.00 | 1.00 | 14-SEP-16:52 | 0.00 | 14-SEP-16:03 | 6594.48 | 18-SEP-08:32 | 4543.75 | 14-SEP-16:52 | 2842.27 | 18-SEP-08:33 | 1376.19 | 14-SEP-16:52 | 0.00 |
| October | 0.451068E+10 | 0.116479E+10 | 729.72 | 0.324529E+10 | 0.126539E+10 | 0.00 | 1.00 | 09-OCT-06:32 | 0.00 | 09-OCT-05:13 | 6661.69 | 23-OCT-07:52 | 4768.39 | 09-OCT-19:42 | 3223.33 | 23-OCT-07:55 | 1380.68 | 31-OCT-07:03 | 0.00 |
| November | 0.442349E+10 | 0.114546E+10 | 688.42 | 0.334634E+10 | 0.107716E+10 | 0.00 | 1.00 | 02-NOV-07:32 | 0.00 | 02-NOV-05:15 | 6549.27 | 02-NOV-07:32 | 4914.53 | 25-NOV-19:52 | 2680.27 | 02-NOV-07:33 | 1396.29 | 19-NOV-08:13 | 0.00 |
| December | 0.441739E+10 | 0.114559E+10 | 682.17 | 0.349103E+10 | 0.926359E+09 | 0.00 | 1.00 | 01-DEC-08:42 | 0.00 | 01-DEC-06:15 | 6589.43 | 24-DEC-08:22 | 5363.34 | 20-DEC-21:32 | 2805.96 | 24-DEC-08:23 | 1420.89 | 24-DEC-09:55 | 0.00 |
| Annual Sum or Average | 0.544799E+11 | 0.143231E+11 | 8502.16 | 0.404707E+11 | 0.140092E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.416428E+10 | 0.110429E+10 | 630.47 | 0.311346E+10 | 0.809330E+09 | 0.00 | 1.00 | 0.00 | 6284.88 | 4444.10 | 1848.24 | 1376.19 | 0.00 | ||||||
| Maximum of Months | 0.503348E+10 | 0.133974E+10 | 741.08 | 0.360606E+10 | 0.152141E+10 | 0.00 | 1.00 | 0.00 | 6661.69 | 5416.38 | 3234.68 | 1473.04 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S SWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 109.81 | 45.24 | 64.57 | 244.37 | 19.18 | 0.00 | 0.00 | 0.00 |
| February | 94.92 | 31.52 | 63.40 | 227.06 | 13.67 | 0.00 | 0.00 | 0.00 |
| March | 64.43 | 8.88 | 55.55 | 171.44 | 7.50 | 0.00 | 0.00 | 0.00 |
| April | 48.48 | 0.51 | 47.97 | 140.18 | 1.91 | 0.00 | 0.00 | 0.00 |
| May | 47.90 | 0.00 | 47.90 | 142.61 | 3.47 | 0.00 | 0.00 | 0.00 |
| June | 47.72 | 0.00 | 47.72 | 140.11 | 3.74 | 0.00 | 0.00 | 0.00 |
| July | 49.16 | 0.00 | 49.16 | 123.86 | 8.24 | 0.00 | 0.00 | 0.00 |
| August | 47.82 | 0.03 | 47.79 | 119.62 | 5.87 | 0.00 | 0.00 | 0.00 |
| September | 52.74 | 1.45 | 51.29 | 135.82 | 6.22 | 0.00 | 0.00 | 0.00 |
| October | 68.88 | 10.61 | 58.27 | 161.77 | 8.82 | 0.00 | 0.00 | 0.00 |
| November | 91.06 | 28.40 | 62.66 | 206.43 | 12.68 | 0.00 | 0.00 | 0.00 |
| December | 110.39 | 46.77 | 63.62 | 241.23 | 22.94 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 69.34 | 14.39 | 54.95 | 170.92 | 9.52 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 47.72 | 0.00 | 47.72 | 119.62 | 1.91 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 110.39 | 46.77 | 64.57 | 244.37 | 22.94 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 W SWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.93 | 19.04 | 34.88 | 118.83 | 13.60 | 0.00 | 0.00 | 0.00 |
| February | 59.08 | 20.91 | 38.17 | 134.12 | 9.71 | 0.00 | 0.00 | 0.00 |
| March | 66.26 | 26.20 | 40.06 | 154.47 | 5.46 | 0.00 | 0.00 | 0.00 |
| April | 66.46 | 25.40 | 41.06 | 160.19 | 1.30 | 0.00 | 0.00 | 0.00 |
| May | 56.62 | 16.77 | 39.85 | 143.60 | 2.24 | 0.00 | 0.00 | 0.00 |
| June | 61.32 | 21.12 | 40.21 | 151.92 | 2.42 | 0.00 | 0.00 | 0.00 |
| July | 52.34 | 12.35 | 39.98 | 122.03 | 5.36 | 0.00 | 0.00 | 0.00 |
| August | 56.93 | 16.88 | 40.05 | 128.90 | 3.80 | 0.00 | 0.00 | 0.00 |
| September | 53.22 | 14.73 | 38.50 | 124.66 | 4.02 | 0.00 | 0.00 | 0.00 |
| October | 50.03 | 12.89 | 37.14 | 111.20 | 5.74 | 0.00 | 0.00 | 0.00 |
| November | 48.72 | 13.24 | 35.48 | 108.20 | 8.44 | 0.00 | 0.00 | 0.00 |
| December | 49.96 | 16.36 | 33.60 | 109.55 | 15.81 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 56.20 | 17.96 | 38.24 | 130.55 | 6.49 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 48.72 | 12.35 | 33.60 | 108.20 | 1.30 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 66.46 | 26.20 | 41.06 | 160.19 | 15.81 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 W NWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.93 | 19.04 | 34.88 | 120.38 | 12.82 | 0.00 | 0.00 | 0.00 |
| February | 59.08 | 20.91 | 38.17 | 135.50 | 9.11 | 0.00 | 0.00 | 0.00 |
| March | 66.26 | 26.20 | 40.06 | 155.13 | 5.23 | 0.00 | 0.00 | 0.00 |
| April | 66.46 | 25.40 | 41.06 | 160.04 | 1.31 | 0.00 | 0.00 | 0.00 |
| May | 56.62 | 16.77 | 39.85 | 142.91 | 2.35 | 0.00 | 0.00 | 0.00 |
| June | 61.32 | 21.12 | 40.21 | 150.66 | 2.58 | 0.00 | 0.00 | 0.00 |
| July | 52.34 | 12.35 | 39.98 | 121.40 | 5.58 | 0.00 | 0.00 | 0.00 |
| August | 56.93 | 16.88 | 40.05 | 128.53 | 3.90 | 0.00 | 0.00 | 0.00 |
| September | 53.22 | 14.73 | 38.50 | 124.82 | 4.00 | 0.00 | 0.00 | 0.00 |
| October | 50.03 | 12.89 | 37.14 | 111.85 | 5.51 | 0.00 | 0.00 | 0.00 |
| November | 48.72 | 13.24 | 35.48 | 109.46 | 7.96 | 0.00 | 0.00 | 0.00 |
| December | 49.96 | 16.36 | 33.60 | 111.14 | 14.98 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 56.20 | 17.96 | 38.24 | 130.89 | 6.28 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 48.72 | 12.35 | 33.60 | 109.46 | 1.31 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 66.46 | 26.20 | 41.06 | 160.04 | 14.98 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N NWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.84 | 0.00 | 41.84 | 99.87 | 19.61 | 0.00 | 0.00 | 0.00 |
| February | 44.64 | 0.00 | 44.64 | 112.68 | 14.10 | 0.00 | 0.00 | 0.00 |
| March | 45.85 | 0.01 | 45.84 | 123.42 | 8.04 | 0.00 | 0.00 | 0.00 |
| April | 50.50 | 0.95 | 49.54 | 142.93 | 2.02 | 0.00 | 0.00 | 0.00 |
| May | 64.09 | 6.99 | 57.10 | 180.77 | 3.70 | 0.00 | 0.00 | 0.00 |
| June | 77.83 | 15.54 | 62.29 | 210.81 | 4.00 | 0.00 | 0.00 | 0.00 |
| July | 66.90 | 6.81 | 60.09 | 165.36 | 8.65 | 0.00 | 0.00 | 0.00 |
| August | 55.69 | 2.74 | 52.95 | 138.02 | 6.31 | 0.00 | 0.00 | 0.00 |
| September | 47.14 | 0.07 | 47.07 | 122.22 | 6.21 | 0.00 | 0.00 | 0.00 |
| October | 45.34 | 0.00 | 45.34 | 108.63 | 8.42 | 0.00 | 0.00 | 0.00 |
| November | 42.90 | 0.00 | 42.90 | 102.99 | 12.15 | 0.00 | 0.00 | 0.00 |
| December | 40.65 | 0.00 | 40.65 | 95.72 | 22.85 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 51.98 | 2.77 | 49.21 | 133.67 | 9.67 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 40.65 | 0.00 | 40.65 | 95.72 | 2.02 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.83 | 15.54 | 62.29 | 210.81 | 22.85 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S SEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 109.81 | 45.24 | 64.57 | 228.73 | 43.29 | 0.00 | 0.00 | 0.00 |
| February | 94.92 | 31.52 | 63.40 | 211.19 | 37.18 | 0.00 | 0.00 | 0.00 |
| March | 64.43 | 8.88 | 55.55 | 155.37 | 30.17 | 0.00 | 0.00 | 0.00 |
| April | 48.48 | 0.51 | 47.97 | 115.76 | 19.96 | 0.00 | 0.00 | 0.00 |
| May | 47.90 | 0.00 | 47.90 | 117.24 | 20.57 | 0.83 | 0.00 | 0.00 |
| June | 47.72 | 0.00 | 47.72 | 117.08 | 21.74 | 0.00 | 0.00 | 0.00 |
| July | 49.16 | 0.00 | 49.16 | 104.80 | 29.90 | 0.00 | 0.00 | 0.00 |
| August | 47.82 | 0.03 | 47.79 | 103.14 | 27.09 | 0.00 | 0.00 | 0.00 |
| September | 52.74 | 1.45 | 51.29 | 117.12 | 27.50 | 0.00 | 0.00 | 0.00 |
| October | 68.88 | 10.61 | 58.27 | 144.98 | 31.99 | 0.00 | 0.00 | 0.00 |
| November | 91.06 | 28.40 | 62.66 | 190.20 | 35.07 | 0.00 | 0.00 | 0.00 |
| December | 110.39 | 46.77 | 63.62 | 227.23 | 45.76 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 69.34 | 14.39 | 54.95 | 152.45 | 30.85 | 0.83 | 0.00 | 0.00 |
| Minimum of Months | 47.72 | 0.00 | 47.72 | 103.14 | 19.96 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 110.39 | 46.77 | 64.57 | 228.73 | 45.76 | 0.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 E SEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.21 | 18.01 | 35.19 | 105.72 | 28.32 | 0.00 | 0.00 | 0.00 |
| February | 60.03 | 21.91 | 38.12 | 124.40 | 24.07 | 0.00 | 0.00 | 0.00 |
| March | 65.66 | 25.67 | 40.00 | 141.75 | 19.26 | 0.00 | 0.00 | 0.00 |
| April | 66.33 | 25.35 | 40.98 | 144.92 | 12.77 | 0.00 | 0.00 | 0.00 |
| May | 56.99 | 17.23 | 39.76 | 128.46 | 13.21 | 1.17 | 0.00 | 0.00 |
| June | 60.74 | 20.02 | 40.72 | 136.50 | 14.01 | 0.00 | 0.00 | 0.00 |
| July | 51.90 | 11.65 | 40.25 | 108.34 | 19.00 | 0.00 | 0.00 | 0.00 |
| August | 57.05 | 16.75 | 40.30 | 119.09 | 17.36 | 0.00 | 0.00 | 0.00 |
| September | 53.64 | 14.64 | 39.00 | 113.70 | 17.50 | 0.00 | 0.00 | 0.00 |
| October | 50.32 | 12.92 | 37.40 | 101.05 | 20.78 | 0.00 | 0.00 | 0.00 |
| November | 48.74 | 13.51 | 35.23 | 97.72 | 23.02 | 0.00 | 0.00 | 0.00 |
| December | 49.79 | 15.99 | 33.80 | 98.71 | 30.03 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 56.16 | 17.76 | 38.39 | 118.26 | 19.94 | 1.17 | 0.00 | 0.00 |
| Minimum of Months | 48.74 | 11.65 | 33.80 | 97.72 | 12.77 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 66.33 | 25.67 | 40.98 | 144.92 | 30.03 | 1.17 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 E NEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.21 | 18.01 | 35.19 | 117.40 | 11.70 | 0.00 | 0.00 | 0.00 |
| February | 60.03 | 21.91 | 38.12 | 136.43 | 8.19 | 0.00 | 0.00 | 0.00 |
| March | 65.66 | 25.67 | 40.00 | 153.71 | 4.47 | 0.00 | 0.00 | 0.00 |
| April | 66.33 | 25.35 | 40.98 | 161.45 | 1.21 | 0.00 | 0.00 | 0.00 |
| May | 56.99 | 17.23 | 39.76 | 144.79 | 2.38 | 0.00 | 0.00 | 0.00 |
| June | 60.74 | 20.02 | 40.72 | 150.32 | 2.59 | 0.00 | 0.00 | 0.00 |
| July | 51.90 | 11.65 | 40.25 | 120.69 | 5.59 | 0.00 | 0.00 | 0.00 |
| August | 57.05 | 16.75 | 40.30 | 129.69 | 4.04 | 0.00 | 0.00 | 0.00 |
| September | 53.64 | 14.64 | 39.00 | 126.60 | 3.98 | 0.00 | 0.00 | 0.00 |
| October | 50.32 | 12.92 | 37.40 | 112.95 | 5.42 | 0.00 | 0.00 | 0.00 |
| November | 48.74 | 13.51 | 35.23 | 109.52 | 7.72 | 0.00 | 0.00 | 0.00 |
| December | 49.79 | 15.99 | 33.80 | 109.24 | 14.05 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 56.16 | 17.76 | 38.39 | 130.96 | 5.95 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 48.74 | 11.65 | 33.80 | 109.24 | 1.21 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 66.33 | 25.67 | 40.98 | 161.45 | 14.05 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N NEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.84 | 0.00 | 41.84 | 99.55 | 19.48 | 0.00 | 0.00 | 0.00 |
| February | 44.64 | 0.00 | 44.64 | 112.38 | 13.97 | 0.00 | 0.00 | 0.00 |
| March | 45.85 | 0.01 | 45.84 | 123.34 | 7.86 | 0.00 | 0.00 | 0.00 |
| April | 50.50 | 0.95 | 49.54 | 142.86 | 1.97 | 0.00 | 0.00 | 0.00 |
| May | 64.09 | 6.99 | 57.10 | 180.64 | 3.66 | 0.00 | 0.00 | 0.00 |
| June | 77.83 | 15.54 | 62.29 | 210.65 | 3.96 | 0.00 | 0.00 | 0.00 |
| July | 66.90 | 6.81 | 60.09 | 165.20 | 8.56 | 0.00 | 0.00 | 0.00 |
| August | 55.69 | 2.74 | 52.95 | 137.81 | 6.24 | 0.00 | 0.00 | 0.00 |
| September | 47.14 | 0.07 | 47.07 | 122.02 | 6.16 | 0.00 | 0.00 | 0.00 |
| October | 45.34 | 0.00 | 45.34 | 108.51 | 8.34 | 0.00 | 0.00 | 0.00 |
| November | 42.90 | 0.00 | 42.90 | 102.83 | 12.08 | 0.00 | 0.00 | 0.00 |
| December | 40.65 | 0.00 | 40.65 | 95.46 | 22.72 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 51.98 | 2.77 | 49.21 | 133.49 | 9.59 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 40.65 | 0.00 | 40.65 | 95.46 | 1.97 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.83 | 15.54 | 62.29 | 210.65 | 22.72 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N N1A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.84 | 0.00 | 41.84 | 101.80 | 18.74 | 0.00 | 0.00 | 0.00 |
| February | 44.64 | 0.00 | 44.64 | 114.97 | 13.11 | 0.00 | 0.00 | 0.00 |
| March | 45.85 | 0.01 | 45.84 | 126.27 | 7.17 | 0.00 | 0.00 | 0.00 |
| April | 50.50 | 0.95 | 49.54 | 146.53 | 1.73 | 0.00 | 0.00 | 0.00 |
| May | 64.09 | 6.99 | 57.10 | 183.89 | 3.29 | 0.00 | 0.00 | 0.00 |
| June | 77.83 | 15.54 | 62.29 | 214.03 | 3.56 | 0.00 | 0.00 | 0.00 |
| July | 66.90 | 6.81 | 60.09 | 167.70 | 7.83 | 0.00 | 0.00 | 0.00 |
| August | 55.69 | 2.74 | 52.95 | 140.60 | 5.65 | 0.00 | 0.00 | 0.00 |
| September | 47.14 | 0.07 | 47.07 | 124.81 | 5.51 | 0.00 | 0.00 | 0.00 |
| October | 45.34 | 0.00 | 45.34 | 110.69 | 7.66 | 0.00 | 0.00 | 0.00 |
| November | 42.90 | 0.00 | 42.90 | 104.98 | 11.40 | 0.00 | 0.00 | 0.00 |
| December | 40.65 | 0.00 | 40.65 | 97.51 | 22.02 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 51.98 | 2.77 | 49.21 | 136.20 | 8.98 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 40.65 | 0.00 | 40.65 | 97.51 | 1.73 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.83 | 15.54 | 62.29 | 214.03 | 22.02 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N N2A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.84 | 0.00 | 41.84 | 101.78 | 18.74 | 0.00 | 0.00 | 0.00 |
| February | 44.64 | 0.00 | 44.64 | 114.96 | 13.11 | 0.00 | 0.00 | 0.00 |
| March | 45.85 | 0.01 | 45.84 | 126.27 | 7.17 | 0.00 | 0.00 | 0.00 |
| April | 50.50 | 0.95 | 49.54 | 146.53 | 1.73 | 0.00 | 0.00 | 0.00 |
| May | 64.09 | 6.99 | 57.10 | 183.89 | 3.29 | 0.00 | 0.00 | 0.00 |
| June | 77.83 | 15.54 | 62.29 | 214.02 | 3.56 | 0.00 | 0.00 | 0.00 |
| July | 66.90 | 6.81 | 60.09 | 167.69 | 7.83 | 0.00 | 0.00 | 0.00 |
| August | 55.69 | 2.74 | 52.95 | 140.59 | 5.65 | 0.00 | 0.00 | 0.00 |
| September | 47.14 | 0.07 | 47.07 | 124.80 | 5.51 | 0.00 | 0.00 | 0.00 |
| October | 45.34 | 0.00 | 45.34 | 110.69 | 7.66 | 0.00 | 0.00 | 0.00 |
| November | 42.90 | 0.00 | 42.90 | 104.97 | 11.40 | 0.00 | 0.00 | 0.00 |
| December | 40.65 | 0.00 | 40.65 | 97.49 | 22.02 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 51.98 | 2.77 | 49.21 | 136.19 | 8.98 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 40.65 | 0.00 | 40.65 | 97.49 | 1.73 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.83 | 15.54 | 62.29 | 214.02 | 22.02 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S S1A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 109.81 | 45.24 | 64.57 | 246.07 | 18.45 | 0.00 | 0.00 | 0.00 |
| February | 94.92 | 31.52 | 63.40 | 229.21 | 12.84 | 0.00 | 0.00 | 0.00 |
| March | 64.43 | 8.88 | 55.55 | 174.31 | 6.76 | 0.00 | 0.00 | 0.00 |
| April | 48.48 | 0.51 | 47.97 | 143.87 | 1.68 | 0.00 | 0.00 | 0.00 |
| May | 47.90 | 0.00 | 47.90 | 145.85 | 3.07 | 0.00 | 0.00 | 0.00 |
| June | 47.72 | 0.00 | 47.72 | 143.61 | 3.32 | 0.00 | 0.00 | 0.00 |
| July | 49.16 | 0.00 | 49.16 | 126.27 | 7.43 | 0.00 | 0.00 | 0.00 |
| August | 47.82 | 0.03 | 47.79 | 122.32 | 5.25 | 0.00 | 0.00 | 0.00 |
| September | 52.74 | 1.45 | 51.29 | 138.39 | 5.55 | 0.00 | 0.00 | 0.00 |
| October | 68.88 | 10.61 | 58.27 | 163.72 | 8.13 | 0.00 | 0.00 | 0.00 |
| November | 91.06 | 28.40 | 62.66 | 208.25 | 12.04 | 0.00 | 0.00 | 0.00 |
| December | 110.39 | 46.77 | 63.62 | 242.77 | 22.25 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 69.34 | 14.39 | 54.95 | 173.43 | 8.90 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 47.72 | 0.00 | 47.72 | 122.32 | 1.68 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 110.39 | 46.77 | 64.57 | 246.07 | 22.25 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S S2A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 109.81 | 45.24 | 64.57 | 245.13 | 19.21 | 0.00 | 0.00 | 0.00 |
| February | 94.92 | 31.52 | 63.40 | 228.27 | 13.54 | 0.00 | 0.00 | 0.00 |
| March | 64.43 | 8.88 | 55.55 | 173.29 | 7.29 | 0.00 | 0.00 | 0.00 |
| April | 48.48 | 0.51 | 47.97 | 142.41 | 1.88 | 0.00 | 0.00 | 0.00 |
| May | 47.90 | 0.00 | 47.90 | 144.46 | 3.38 | 0.00 | 0.00 | 0.00 |
| June | 47.72 | 0.00 | 47.72 | 142.28 | 3.64 | 0.00 | 0.00 | 0.00 |
| July | 49.16 | 0.00 | 49.16 | 125.25 | 8.04 | 0.00 | 0.00 | 0.00 |
| August | 47.82 | 0.03 | 47.79 | 121.22 | 5.73 | 0.00 | 0.00 | 0.00 |
| September | 52.74 | 1.45 | 51.29 | 137.31 | 6.07 | 0.00 | 0.00 | 0.00 |
| October | 68.88 | 10.61 | 58.27 | 162.78 | 8.83 | 0.00 | 0.00 | 0.00 |
| November | 91.06 | 28.40 | 62.66 | 207.34 | 12.72 | 0.00 | 0.00 | 0.00 |
| December | 110.39 | 46.77 | 63.62 | 241.96 | 22.96 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 69.34 | 14.39 | 54.95 | 172.35 | 9.44 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 47.72 | 0.00 | 47.72 | 121.22 | 1.88 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 110.39 | 46.77 | 64.57 | 245.13 | 22.96 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S SWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 109.81 | 45.24 | 64.57 | 245.64 | 17.25 | 0.00 | 0.00 | 0.00 |
| February | 94.92 | 31.52 | 63.40 | 228.73 | 11.69 | 0.00 | 0.00 | 0.00 |
| March | 64.43 | 8.88 | 55.55 | 173.82 | 6.03 | 0.00 | 0.00 | 0.00 |
| April | 48.48 | 0.51 | 47.97 | 143.91 | 1.46 | 0.00 | 0.00 | 0.00 |
| May | 47.90 | 0.00 | 47.90 | 146.25 | 2.68 | 0.00 | 0.00 | 0.00 |
| June | 47.72 | 0.00 | 47.72 | 144.08 | 2.94 | 0.00 | 0.00 | 0.00 |
| July | 49.16 | 0.00 | 49.16 | 126.40 | 6.62 | 0.00 | 0.00 | 0.00 |
| August | 47.82 | 0.03 | 47.79 | 122.71 | 4.49 | 0.00 | 0.00 | 0.00 |
| September | 52.74 | 1.45 | 51.29 | 138.52 | 4.85 | 0.00 | 0.00 | 0.00 |
| October | 68.88 | 10.61 | 58.27 | 163.46 | 7.24 | 0.00 | 0.00 | 0.00 |
| November | 91.06 | 28.40 | 62.66 | 207.97 | 10.98 | 0.00 | 0.00 | 0.00 |
| December | 110.39 | 46.77 | 63.62 | 242.48 | 20.99 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 69.34 | 14.39 | 54.95 | 173.38 | 8.11 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 47.72 | 0.00 | 47.72 | 122.71 | 1.46 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 110.39 | 46.77 | 64.57 | 245.64 | 20.99 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 W SWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.93 | 19.04 | 34.88 | 119.76 | 12.28 | 0.00 | 0.00 | 0.00 |
| February | 59.08 | 20.91 | 38.17 | 135.17 | 8.37 | 0.00 | 0.00 | 0.00 |
| March | 66.26 | 26.20 | 40.06 | 155.67 | 4.50 | 0.00 | 0.00 | 0.00 |
| April | 66.46 | 25.40 | 41.06 | 162.08 | 0.98 | 0.00 | 0.00 | 0.00 |
| May | 56.62 | 16.77 | 39.85 | 145.63 | 1.73 | 0.00 | 0.00 | 0.00 |
| June | 61.32 | 21.12 | 40.21 | 154.13 | 1.92 | 0.00 | 0.00 | 0.00 |
| July | 52.34 | 12.35 | 39.98 | 123.43 | 4.31 | 0.00 | 0.00 | 0.00 |
| August | 56.93 | 16.88 | 40.05 | 130.61 | 2.92 | 0.00 | 0.00 | 0.00 |
| September | 53.22 | 14.73 | 38.50 | 126.25 | 3.14 | 0.00 | 0.00 | 0.00 |
| October | 50.03 | 12.89 | 37.14 | 112.30 | 4.69 | 0.00 | 0.00 | 0.00 |
| November | 48.72 | 13.24 | 35.48 | 109.30 | 7.27 | 0.00 | 0.00 | 0.00 |
| December | 49.96 | 16.36 | 33.60 | 110.49 | 14.44 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 56.20 | 17.96 | 38.24 | 131.98 | 5.55 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 48.72 | 12.35 | 33.60 | 109.30 | 0.98 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 66.46 | 26.20 | 41.06 | 162.08 | 14.44 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 W NWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.93 | 19.04 | 34.88 | 121.24 | 11.69 | 0.00 | 0.00 | 0.00 |
| February | 59.08 | 20.91 | 38.17 | 136.49 | 7.95 | 0.00 | 0.00 | 0.00 |
| March | 66.26 | 26.20 | 40.06 | 156.28 | 4.34 | 0.00 | 0.00 | 0.00 |
| April | 66.46 | 25.40 | 41.06 | 161.97 | 0.98 | 0.00 | 0.00 | 0.00 |
| May | 56.62 | 16.77 | 39.85 | 145.05 | 1.80 | 0.00 | 0.00 | 0.00 |
| June | 61.32 | 21.12 | 40.21 | 153.03 | 2.02 | 0.00 | 0.00 | 0.00 |
| July | 52.34 | 12.35 | 39.98 | 122.88 | 4.46 | 0.00 | 0.00 | 0.00 |
| August | 56.93 | 16.88 | 40.05 | 130.28 | 2.97 | 0.00 | 0.00 | 0.00 |
| September | 53.22 | 14.73 | 38.50 | 126.42 | 3.11 | 0.00 | 0.00 | 0.00 |
| October | 50.03 | 12.89 | 37.14 | 112.92 | 4.51 | 0.00 | 0.00 | 0.00 |
| November | 48.72 | 13.24 | 35.48 | 110.49 | 6.92 | 0.00 | 0.00 | 0.00 |
| December | 49.96 | 16.36 | 33.60 | 112.05 | 13.81 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 56.20 | 17.96 | 38.24 | 132.33 | 5.38 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 48.72 | 12.35 | 33.60 | 110.49 | 0.98 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 66.46 | 26.20 | 41.06 | 161.97 | 13.81 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N NWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.84 | 0.00 | 41.84 | 101.59 | 17.84 | 0.00 | 0.00 | 0.00 |
| February | 44.64 | 0.00 | 44.64 | 114.61 | 12.27 | 0.00 | 0.00 | 0.00 |
| March | 45.85 | 0.01 | 45.84 | 125.73 | 6.66 | 0.00 | 0.00 | 0.00 |
| April | 50.50 | 0.95 | 49.54 | 146.27 | 1.50 | 0.00 | 0.00 | 0.00 |
| May | 64.09 | 6.99 | 57.10 | 183.99 | 2.86 | 0.00 | 0.00 | 0.00 |
| June | 77.83 | 15.54 | 62.29 | 214.14 | 3.12 | 0.00 | 0.00 | 0.00 |
| July | 66.90 | 6.81 | 60.09 | 167.62 | 6.97 | 0.00 | 0.00 | 0.00 |
| August | 55.69 | 2.74 | 52.95 | 140.83 | 4.92 | 0.00 | 0.00 | 0.00 |
| September | 47.14 | 0.07 | 47.07 | 124.95 | 4.83 | 0.00 | 0.00 | 0.00 |
| October | 45.34 | 0.00 | 45.34 | 110.58 | 6.86 | 0.00 | 0.00 | 0.00 |
| November | 42.90 | 0.00 | 42.90 | 104.88 | 10.50 | 0.00 | 0.00 | 0.00 |
| December | 40.65 | 0.00 | 40.65 | 97.47 | 20.99 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 51.98 | 2.77 | 49.21 | 136.11 | 8.28 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 40.65 | 0.00 | 40.65 | 97.47 | 1.50 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.83 | 15.54 | 62.29 | 214.14 | 20.99 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S SEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 109.81 | 45.24 | 64.57 | 245.30 | 17.09 | 0.00 | 0.00 | 0.00 |
| February | 94.92 | 31.52 | 63.40 | 228.41 | 11.57 | 0.00 | 0.00 | 0.00 |
| March | 64.43 | 8.88 | 55.55 | 173.78 | 5.89 | 0.00 | 0.00 | 0.00 |
| April | 48.48 | 0.51 | 47.97 | 143.88 | 1.44 | 0.00 | 0.00 | 0.00 |
| May | 47.90 | 0.00 | 47.90 | 146.13 | 2.64 | 0.00 | 0.00 | 0.00 |
| June | 47.72 | 0.00 | 47.72 | 143.93 | 2.91 | 0.00 | 0.00 | 0.00 |
| July | 49.16 | 0.00 | 49.16 | 126.24 | 6.53 | 0.00 | 0.00 | 0.00 |
| August | 47.82 | 0.03 | 47.79 | 122.50 | 4.43 | 0.00 | 0.00 | 0.00 |
| September | 52.74 | 1.45 | 51.29 | 138.34 | 4.80 | 0.00 | 0.00 | 0.00 |
| October | 68.88 | 10.61 | 58.27 | 163.34 | 7.16 | 0.00 | 0.00 | 0.00 |
| November | 91.06 | 28.40 | 62.66 | 207.80 | 10.90 | 0.00 | 0.00 | 0.00 |
| December | 110.39 | 46.77 | 63.62 | 242.18 | 20.84 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 69.34 | 14.39 | 54.95 | 173.20 | 8.02 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 47.72 | 0.00 | 47.72 | 122.50 | 1.44 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 110.39 | 46.77 | 64.57 | 245.30 | 20.84 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 E SEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.21 | 18.01 | 35.19 | 116.89 | 11.15 | 0.00 | 0.00 | 0.00 |
| February | 60.03 | 21.91 | 38.12 | 136.25 | 7.45 | 0.00 | 0.00 | 0.00 |
| March | 65.66 | 25.67 | 40.00 | 154.41 | 3.74 | 0.00 | 0.00 | 0.00 |
| April | 66.33 | 25.35 | 40.98 | 163.68 | 0.92 | 0.00 | 0.00 | 0.00 |
| May | 56.99 | 17.23 | 39.76 | 147.55 | 1.78 | 0.00 | 0.00 | 0.00 |
| June | 60.74 | 20.02 | 40.72 | 153.68 | 1.92 | 0.00 | 0.00 | 0.00 |
| July | 51.90 | 11.65 | 40.25 | 122.77 | 4.35 | 0.00 | 0.00 | 0.00 |
| August | 57.05 | 16.75 | 40.30 | 131.75 | 3.09 | 0.00 | 0.00 | 0.00 |
| September | 53.64 | 14.64 | 39.00 | 128.07 | 3.12 | 0.00 | 0.00 | 0.00 |
| October | 50.32 | 12.92 | 37.40 | 113.44 | 4.62 | 0.00 | 0.00 | 0.00 |
| November | 48.74 | 13.51 | 35.23 | 109.39 | 7.06 | 0.00 | 0.00 | 0.00 |
| December | 49.79 | 15.99 | 33.80 | 108.64 | 13.53 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 56.16 | 17.76 | 38.39 | 132.11 | 5.23 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 48.74 | 11.65 | 33.80 | 108.64 | 0.92 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 66.33 | 25.67 | 40.98 | 163.68 | 13.53 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 E NEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.21 | 18.01 | 35.19 | 118.42 | 10.63 | 0.00 | 0.00 | 0.00 |
| February | 60.03 | 21.91 | 38.12 | 137.63 | 7.09 | 0.00 | 0.00 | 0.00 |
| March | 65.66 | 25.67 | 40.00 | 155.06 | 3.60 | 0.00 | 0.00 | 0.00 |
| April | 66.33 | 25.35 | 40.98 | 163.57 | 0.92 | 0.00 | 0.00 | 0.00 |
| May | 56.99 | 17.23 | 39.76 | 146.96 | 1.85 | 0.00 | 0.00 | 0.00 |
| June | 60.74 | 20.02 | 40.72 | 152.61 | 2.02 | 0.00 | 0.00 | 0.00 |
| July | 51.90 | 11.65 | 40.25 | 122.22 | 4.50 | 0.00 | 0.00 | 0.00 |
| August | 57.05 | 16.75 | 40.30 | 131.43 | 3.14 | 0.00 | 0.00 | 0.00 |
| September | 53.64 | 14.64 | 39.00 | 128.24 | 3.10 | 0.00 | 0.00 | 0.00 |
| October | 50.32 | 12.92 | 37.40 | 114.07 | 4.45 | 0.00 | 0.00 | 0.00 |
| November | 48.74 | 13.51 | 35.23 | 110.60 | 6.71 | 0.00 | 0.00 | 0.00 |
| December | 49.79 | 15.99 | 33.80 | 110.24 | 12.96 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 56.16 | 17.76 | 38.39 | 132.48 | 5.08 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 48.74 | 11.65 | 33.80 | 110.24 | 0.92 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 66.33 | 25.67 | 40.98 | 163.57 | 12.96 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N NEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.84 | 0.00 | 41.84 | 101.20 | 17.72 | 0.00 | 0.00 | 0.00 |
| February | 44.64 | 0.00 | 44.64 | 114.27 | 12.17 | 0.00 | 0.00 | 0.00 |
| March | 45.85 | 0.01 | 45.84 | 125.67 | 6.51 | 0.00 | 0.00 | 0.00 |
| April | 50.50 | 0.95 | 49.54 | 146.23 | 1.47 | 0.00 | 0.00 | 0.00 |
| May | 64.09 | 6.99 | 57.10 | 183.87 | 2.82 | 0.00 | 0.00 | 0.00 |
| June | 77.83 | 15.54 | 62.29 | 213.98 | 3.08 | 0.00 | 0.00 | 0.00 |
| July | 66.90 | 6.81 | 60.09 | 167.46 | 6.89 | 0.00 | 0.00 | 0.00 |
| August | 55.69 | 2.74 | 52.95 | 140.63 | 4.85 | 0.00 | 0.00 | 0.00 |
| September | 47.14 | 0.07 | 47.07 | 124.77 | 4.78 | 0.00 | 0.00 | 0.00 |
| October | 45.34 | 0.00 | 45.34 | 110.46 | 6.78 | 0.00 | 0.00 | 0.00 |
| November | 42.90 | 0.00 | 42.90 | 104.70 | 10.43 | 0.00 | 0.00 | 0.00 |
| December | 40.65 | 0.00 | 40.65 | 97.14 | 20.88 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 51.98 | 2.77 | 49.21 | 135.92 | 8.20 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 40.65 | 0.00 | 40.65 | 97.14 | 1.47 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.83 | 15.54 | 62.29 | 213.98 | 20.88 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N N1A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.84 | 0.00 | 41.84 | 103.33 | 17.26 | 0.00 | 0.00 | 0.00 |
| February | 44.64 | 0.00 | 44.64 | 116.74 | 11.63 | 0.00 | 0.00 | 0.00 |
| March | 45.85 | 0.01 | 45.84 | 128.40 | 6.07 | 0.00 | 0.00 | 0.00 |
| April | 50.50 | 0.95 | 49.54 | 149.50 | 1.35 | 0.00 | 0.00 | 0.00 |
| May | 64.09 | 6.99 | 57.10 | 186.69 | 2.60 | 0.00 | 0.00 | 0.00 |
| June | 77.83 | 15.54 | 62.29 | 216.87 | 2.86 | 0.00 | 0.00 | 0.00 |
| July | 66.90 | 6.81 | 60.09 | 169.58 | 6.47 | 0.00 | 0.00 | 0.00 |
| August | 55.69 | 2.74 | 52.95 | 143.00 | 4.55 | 0.00 | 0.00 | 0.00 |
| September | 47.14 | 0.07 | 47.07 | 127.15 | 4.43 | 0.00 | 0.00 | 0.00 |
| October | 45.34 | 0.00 | 45.34 | 112.41 | 6.38 | 0.00 | 0.00 | 0.00 |
| November | 42.90 | 0.00 | 42.90 | 106.63 | 10.02 | 0.00 | 0.00 | 0.00 |
| December | 40.65 | 0.00 | 40.65 | 99.02 | 20.48 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 51.98 | 2.77 | 49.21 | 138.33 | 7.84 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 40.65 | 0.00 | 40.65 | 99.02 | 1.35 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.83 | 15.54 | 62.29 | 216.87 | 20.48 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N N2A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.84 | 0.00 | 41.84 | 103.31 | 17.26 | 0.00 | 0.00 | 0.00 |
| February | 44.64 | 0.00 | 44.64 | 116.73 | 11.62 | 0.00 | 0.00 | 0.00 |
| March | 45.85 | 0.01 | 45.84 | 128.40 | 6.07 | 0.00 | 0.00 | 0.00 |
| April | 50.50 | 0.95 | 49.54 | 149.50 | 1.35 | 0.00 | 0.00 | 0.00 |
| May | 64.09 | 6.99 | 57.10 | 186.69 | 2.60 | 0.00 | 0.00 | 0.00 |
| June | 77.83 | 15.54 | 62.29 | 216.87 | 2.86 | 0.00 | 0.00 | 0.00 |
| July | 66.90 | 6.81 | 60.09 | 169.58 | 6.47 | 0.00 | 0.00 | 0.00 |
| August | 55.69 | 2.74 | 52.95 | 142.99 | 4.55 | 0.00 | 0.00 | 0.00 |
| September | 47.14 | 0.07 | 47.07 | 127.15 | 4.43 | 0.00 | 0.00 | 0.00 |
| October | 45.34 | 0.00 | 45.34 | 112.41 | 6.38 | 0.00 | 0.00 | 0.00 |
| November | 42.90 | 0.00 | 42.90 | 106.62 | 10.01 | 0.00 | 0.00 | 0.00 |
| December | 40.65 | 0.00 | 40.65 | 99.01 | 20.48 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 51.98 | 2.77 | 49.21 | 138.32 | 7.84 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 40.65 | 0.00 | 40.65 | 99.01 | 1.35 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.83 | 15.54 | 62.29 | 216.87 | 20.48 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S S1A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 109.81 | 45.24 | 64.57 | 247.22 | 16.73 | 0.00 | 0.00 | 0.00 |
| February | 94.92 | 31.52 | 63.40 | 230.76 | 11.14 | 0.00 | 0.00 | 0.00 |
| March | 64.43 | 8.88 | 55.55 | 176.51 | 5.49 | 0.00 | 0.00 | 0.00 |
| April | 48.48 | 0.51 | 47.97 | 147.26 | 1.33 | 0.00 | 0.00 | 0.00 |
| May | 47.90 | 0.00 | 47.90 | 149.11 | 2.42 | 0.00 | 0.00 | 0.00 |
| June | 47.72 | 0.00 | 47.72 | 147.10 | 2.67 | 0.00 | 0.00 | 0.00 |
| July | 49.16 | 0.00 | 49.16 | 128.46 | 6.10 | 0.00 | 0.00 | 0.00 |
| August | 47.82 | 0.03 | 47.79 | 125.01 | 4.12 | 0.00 | 0.00 | 0.00 |
| September | 52.74 | 1.45 | 51.29 | 140.73 | 4.45 | 0.00 | 0.00 | 0.00 |
| October | 68.88 | 10.61 | 58.27 | 165.23 | 6.78 | 0.00 | 0.00 | 0.00 |
| November | 91.06 | 28.40 | 62.66 | 209.59 | 10.55 | 0.00 | 0.00 | 0.00 |
| December | 110.39 | 46.77 | 63.62 | 243.86 | 20.53 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 69.34 | 14.39 | 54.95 | 175.61 | 7.70 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 47.72 | 0.00 | 47.72 | 125.01 | 1.33 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 110.39 | 46.77 | 64.57 | 247.22 | 20.53 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S S2A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 109.81 | 45.24 | 64.57 | 247.20 | 16.73 | 0.00 | 0.00 | 0.00 |
| February | 94.92 | 31.52 | 63.40 | 230.75 | 11.14 | 0.00 | 0.00 | 0.00 |
| March | 64.43 | 8.88 | 55.55 | 176.50 | 5.48 | 0.00 | 0.00 | 0.00 |
| April | 48.48 | 0.51 | 47.97 | 147.26 | 1.33 | 0.00 | 0.00 | 0.00 |
| May | 47.90 | 0.00 | 47.90 | 149.10 | 2.42 | 0.00 | 0.00 | 0.00 |
| June | 47.72 | 0.00 | 47.72 | 147.09 | 2.67 | 0.00 | 0.00 | 0.00 |
| July | 49.16 | 0.00 | 49.16 | 128.45 | 6.10 | 0.00 | 0.00 | 0.00 |
| August | 47.82 | 0.03 | 47.79 | 125.00 | 4.12 | 0.00 | 0.00 | 0.00 |
| September | 52.74 | 1.45 | 51.29 | 140.72 | 4.45 | 0.00 | 0.00 | 0.00 |
| October | 68.88 | 10.61 | 58.27 | 165.22 | 6.77 | 0.00 | 0.00 | 0.00 |
| November | 91.06 | 28.40 | 62.66 | 209.58 | 10.55 | 0.00 | 0.00 | 0.00 |
| December | 110.39 | 46.77 | 63.62 | 243.84 | 20.53 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 69.34 | 14.39 | 54.95 | 175.61 | 7.69 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 47.72 | 0.00 | 47.72 | 125.00 | 1.33 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 110.39 | 46.77 | 64.57 | 247.20 | 20.53 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S SWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 109.81 | 45.24 | 64.57 | 241.36 | 16.72 | 0.00 | 0.00 | 0.00 |
| February | 94.92 | 31.52 | 63.40 | 224.18 | 11.10 | 0.00 | 0.00 | 0.00 |
| March | 64.43 | 8.88 | 55.55 | 169.20 | 5.73 | 0.00 | 0.00 | 0.00 |
| April | 48.48 | 0.51 | 47.97 | 139.23 | 1.40 | 0.00 | 0.00 | 0.00 |
| May | 47.90 | 0.00 | 47.90 | 141.75 | 2.69 | 0.00 | 0.00 | 0.00 |
| June | 47.72 | 0.00 | 47.72 | 139.48 | 3.00 | 0.00 | 0.00 | 0.00 |
| July | 49.16 | 0.00 | 49.16 | 122.43 | 6.66 | 0.00 | 0.00 | 0.00 |
| August | 47.82 | 0.03 | 47.79 | 118.77 | 4.45 | 0.00 | 0.00 | 0.00 |
| September | 52.74 | 1.45 | 51.29 | 134.35 | 4.94 | 0.00 | 0.00 | 0.00 |
| October | 68.88 | 10.61 | 58.27 | 159.53 | 7.27 | 0.00 | 0.00 | 0.00 |
| November | 91.06 | 28.40 | 62.66 | 203.85 | 10.73 | 0.00 | 0.00 | 0.00 |
| December | 110.39 | 46.77 | 63.62 | 238.49 | 20.46 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 69.34 | 14.39 | 54.95 | 169.10 | 7.94 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 47.72 | 0.00 | 47.72 | 118.77 | 1.40 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 110.39 | 46.77 | 64.57 | 241.36 | 20.46 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 W SWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.93 | 19.04 | 34.88 | 116.86 | 11.85 | 0.00 | 0.00 | 0.00 |
| February | 59.08 | 20.91 | 38.17 | 132.08 | 7.94 | 0.00 | 0.00 | 0.00 |
| March | 66.26 | 26.20 | 40.06 | 152.57 | 4.35 | 0.00 | 0.00 | 0.00 |
| April | 66.46 | 25.40 | 41.06 | 158.82 | 0.94 | 0.00 | 0.00 | 0.00 |
| May | 56.62 | 16.77 | 39.85 | 142.48 | 1.73 | 0.00 | 0.00 | 0.00 |
| June | 61.32 | 21.12 | 40.21 | 150.87 | 1.94 | 0.00 | 0.00 | 0.00 |
| July | 52.34 | 12.35 | 39.98 | 120.61 | 4.32 | 0.00 | 0.00 | 0.00 |
| August | 56.93 | 16.88 | 40.05 | 127.79 | 2.88 | 0.00 | 0.00 | 0.00 |
| September | 53.22 | 14.73 | 38.50 | 123.33 | 3.17 | 0.00 | 0.00 | 0.00 |
| October | 50.03 | 12.89 | 37.14 | 109.66 | 4.68 | 0.00 | 0.00 | 0.00 |
| November | 48.72 | 13.24 | 35.48 | 106.52 | 7.05 | 0.00 | 0.00 | 0.00 |
| December | 49.96 | 16.36 | 33.60 | 107.75 | 13.99 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 56.20 | 17.96 | 38.24 | 129.02 | 5.41 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 48.72 | 12.35 | 33.60 | 106.52 | 0.94 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 66.46 | 26.20 | 41.06 | 158.82 | 13.99 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 W NWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.93 | 19.04 | 34.88 | 118.91 | 11.38 | 0.00 | 0.00 | 0.00 |
| February | 59.08 | 20.91 | 38.17 | 133.85 | 7.63 | 0.00 | 0.00 | 0.00 |
| March | 66.26 | 26.20 | 40.06 | 153.35 | 4.23 | 0.00 | 0.00 | 0.00 |
| April | 66.46 | 25.40 | 41.06 | 158.68 | 0.94 | 0.00 | 0.00 | 0.00 |
| May | 56.62 | 16.77 | 39.85 | 141.72 | 1.78 | 0.00 | 0.00 | 0.00 |
| June | 61.32 | 21.12 | 40.21 | 149.49 | 2.02 | 0.00 | 0.00 | 0.00 |
| July | 52.34 | 12.35 | 39.98 | 119.87 | 4.43 | 0.00 | 0.00 | 0.00 |
| August | 56.93 | 16.88 | 40.05 | 127.37 | 2.92 | 0.00 | 0.00 | 0.00 |
| September | 53.22 | 14.73 | 38.50 | 123.55 | 3.16 | 0.00 | 0.00 | 0.00 |
| October | 50.03 | 12.89 | 37.14 | 110.47 | 4.55 | 0.00 | 0.00 | 0.00 |
| November | 48.72 | 13.24 | 35.48 | 108.12 | 6.80 | 0.00 | 0.00 | 0.00 |
| December | 49.96 | 16.36 | 33.60 | 109.88 | 13.47 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 56.20 | 17.96 | 38.24 | 129.51 | 5.28 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 48.72 | 12.35 | 33.60 | 108.12 | 0.94 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 66.46 | 26.20 | 41.06 | 158.68 | 13.47 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N NWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.84 | 0.00 | 41.84 | 98.21 | 17.41 | 0.00 | 0.00 | 0.00 |
| February | 44.64 | 0.00 | 44.64 | 110.85 | 11.86 | 0.00 | 0.00 | 0.00 |
| March | 45.85 | 0.01 | 45.84 | 121.53 | 6.51 | 0.00 | 0.00 | 0.00 |
| April | 50.50 | 0.95 | 49.54 | 141.50 | 1.44 | 0.00 | 0.00 | 0.00 |
| May | 64.09 | 6.99 | 57.10 | 179.19 | 2.86 | 0.00 | 0.00 | 0.00 |
| June | 77.83 | 15.54 | 62.29 | 209.09 | 3.15 | 0.00 | 0.00 | 0.00 |
| July | 66.90 | 6.81 | 60.09 | 163.30 | 6.99 | 0.00 | 0.00 | 0.00 |
| August | 55.69 | 2.74 | 52.95 | 136.82 | 4.90 | 0.00 | 0.00 | 0.00 |
| September | 47.14 | 0.07 | 47.07 | 120.94 | 4.93 | 0.00 | 0.00 | 0.00 |
| October | 45.34 | 0.00 | 45.34 | 107.09 | 6.95 | 0.00 | 0.00 | 0.00 |
| November | 42.90 | 0.00 | 42.90 | 101.45 | 10.35 | 0.00 | 0.00 | 0.00 |
| December | 40.65 | 0.00 | 40.65 | 94.35 | 20.51 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 51.98 | 2.77 | 49.21 | 132.08 | 8.16 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 40.65 | 0.00 | 40.65 | 94.35 | 1.44 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.83 | 15.54 | 62.29 | 209.09 | 20.51 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S SEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 109.81 | 45.24 | 64.57 | 240.83 | 16.45 | 0.00 | 0.00 | 0.00 |
| February | 94.92 | 31.52 | 63.40 | 223.73 | 10.91 | 0.00 | 0.00 | 0.00 |
| March | 64.43 | 8.88 | 55.55 | 169.15 | 5.54 | 0.00 | 0.00 | 0.00 |
| April | 48.48 | 0.51 | 47.97 | 139.21 | 1.37 | 0.00 | 0.00 | 0.00 |
| May | 47.90 | 0.00 | 47.90 | 141.60 | 2.64 | 0.00 | 0.00 | 0.00 |
| June | 47.72 | 0.00 | 47.72 | 139.25 | 2.94 | 0.00 | 0.00 | 0.00 |
| July | 49.16 | 0.00 | 49.16 | 122.20 | 6.53 | 0.00 | 0.00 | 0.00 |
| August | 47.82 | 0.03 | 47.79 | 118.47 | 4.35 | 0.00 | 0.00 | 0.00 |
| September | 52.74 | 1.45 | 51.29 | 134.10 | 4.84 | 0.00 | 0.00 | 0.00 |
| October | 68.88 | 10.61 | 58.27 | 159.34 | 7.14 | 0.00 | 0.00 | 0.00 |
| November | 91.06 | 28.40 | 62.66 | 203.61 | 10.60 | 0.00 | 0.00 | 0.00 |
| December | 110.39 | 46.77 | 63.62 | 237.99 | 20.20 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 69.34 | 14.39 | 54.95 | 168.84 | 7.80 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 47.72 | 0.00 | 47.72 | 118.47 | 1.37 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 110.39 | 46.77 | 64.57 | 240.83 | 20.20 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 E SEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.21 | 18.01 | 35.19 | 113.92 | 10.72 | 0.00 | 0.00 | 0.00 |
| February | 60.03 | 21.91 | 38.12 | 133.09 | 7.00 | 0.00 | 0.00 | 0.00 |
| March | 65.66 | 25.67 | 40.00 | 151.13 | 3.52 | 0.00 | 0.00 | 0.00 |
| April | 66.33 | 25.35 | 40.98 | 160.36 | 0.87 | 0.00 | 0.00 | 0.00 |
| May | 56.99 | 17.23 | 39.76 | 144.39 | 1.79 | 0.00 | 0.00 | 0.00 |
| June | 60.74 | 20.02 | 40.72 | 150.47 | 1.94 | 0.00 | 0.00 | 0.00 |
| July | 51.90 | 11.65 | 40.25 | 120.06 | 4.36 | 0.00 | 0.00 | 0.00 |
| August | 57.05 | 16.75 | 40.30 | 129.04 | 3.05 | 0.00 | 0.00 | 0.00 |
| September | 53.64 | 14.64 | 39.00 | 125.24 | 3.15 | 0.00 | 0.00 | 0.00 |
| October | 50.32 | 12.92 | 37.40 | 110.78 | 4.60 | 0.00 | 0.00 | 0.00 |
| November | 48.74 | 13.51 | 35.23 | 106.59 | 6.85 | 0.00 | 0.00 | 0.00 |
| December | 49.79 | 15.99 | 33.80 | 105.86 | 13.10 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 56.16 | 17.76 | 38.39 | 129.14 | 5.08 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 48.74 | 11.65 | 33.80 | 105.86 | 0.87 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 66.33 | 25.67 | 40.98 | 160.36 | 13.10 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 E NEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 53.21 | 18.01 | 35.19 | 115.98 | 10.31 | 0.00 | 0.00 | 0.00 |
| February | 60.03 | 21.91 | 38.12 | 134.91 | 6.75 | 0.00 | 0.00 | 0.00 |
| March | 65.66 | 25.67 | 40.00 | 151.96 | 3.41 | 0.00 | 0.00 | 0.00 |
| April | 66.33 | 25.35 | 40.98 | 160.21 | 0.87 | 0.00 | 0.00 | 0.00 |
| May | 56.99 | 17.23 | 39.76 | 143.64 | 1.83 | 0.00 | 0.00 | 0.00 |
| June | 60.74 | 20.02 | 40.72 | 149.13 | 2.02 | 0.00 | 0.00 | 0.00 |
| July | 51.90 | 11.65 | 40.25 | 119.33 | 4.48 | 0.00 | 0.00 | 0.00 |
| August | 57.05 | 16.75 | 40.30 | 128.63 | 3.09 | 0.00 | 0.00 | 0.00 |
| September | 53.64 | 14.64 | 39.00 | 125.46 | 3.14 | 0.00 | 0.00 | 0.00 |
| October | 50.32 | 12.92 | 37.40 | 111.60 | 4.47 | 0.00 | 0.00 | 0.00 |
| November | 48.74 | 13.51 | 35.23 | 108.20 | 6.61 | 0.00 | 0.00 | 0.00 |
| December | 49.79 | 15.99 | 33.80 | 108.02 | 12.64 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 56.16 | 17.76 | 38.39 | 129.65 | 4.97 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 48.74 | 11.65 | 33.80 | 108.02 | 0.87 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 66.33 | 25.67 | 40.98 | 160.21 | 12.64 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N NEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.84 | 0.00 | 41.84 | 97.58 | 17.18 | 0.00 | 0.00 | 0.00 |
| February | 44.64 | 0.00 | 44.64 | 110.32 | 11.68 | 0.00 | 0.00 | 0.00 |
| March | 45.85 | 0.01 | 45.84 | 121.42 | 6.30 | 0.00 | 0.00 | 0.00 |
| April | 50.50 | 0.95 | 49.54 | 141.46 | 1.40 | 0.00 | 0.00 | 0.00 |
| May | 64.09 | 6.99 | 57.10 | 179.03 | 2.80 | 0.00 | 0.00 | 0.00 |
| June | 77.83 | 15.54 | 62.29 | 208.86 | 3.08 | 0.00 | 0.00 | 0.00 |
| July | 66.90 | 6.81 | 60.09 | 163.05 | 6.85 | 0.00 | 0.00 | 0.00 |
| August | 55.69 | 2.74 | 52.95 | 136.53 | 4.78 | 0.00 | 0.00 | 0.00 |
| September | 47.14 | 0.07 | 47.07 | 120.68 | 4.84 | 0.00 | 0.00 | 0.00 |
| October | 45.34 | 0.00 | 45.34 | 106.90 | 6.82 | 0.00 | 0.00 | 0.00 |
| November | 42.90 | 0.00 | 42.90 | 101.19 | 10.23 | 0.00 | 0.00 | 0.00 |
| December | 40.65 | 0.00 | 40.65 | 93.83 | 20.30 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 51.98 | 2.77 | 49.21 | 131.79 | 8.03 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 40.65 | 0.00 | 40.65 | 93.83 | 1.40 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.83 | 15.54 | 62.29 | 208.86 | 20.30 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N N1A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.84 | 0.00 | 41.84 | 100.43 | 17.07 | 0.00 | 0.00 | 0.00 |
| February | 44.64 | 0.00 | 44.64 | 113.55 | 11.45 | 0.00 | 0.00 | 0.00 |
| March | 45.85 | 0.01 | 45.84 | 124.84 | 6.10 | 0.00 | 0.00 | 0.00 |
| April | 50.50 | 0.95 | 49.54 | 145.32 | 1.35 | 0.00 | 0.00 | 0.00 |
| May | 64.09 | 6.99 | 57.10 | 182.43 | 2.71 | 0.00 | 0.00 | 0.00 |
| June | 77.83 | 15.54 | 62.29 | 212.36 | 2.98 | 0.00 | 0.00 | 0.00 |
| July | 66.90 | 6.81 | 60.09 | 165.78 | 6.66 | 0.00 | 0.00 | 0.00 |
| August | 55.69 | 2.74 | 52.95 | 139.47 | 4.66 | 0.00 | 0.00 | 0.00 |
| September | 47.14 | 0.07 | 47.07 | 123.64 | 4.68 | 0.00 | 0.00 | 0.00 |
| October | 45.34 | 0.00 | 45.34 | 109.38 | 6.67 | 0.00 | 0.00 | 0.00 |
| November | 42.90 | 0.00 | 42.90 | 103.70 | 10.11 | 0.00 | 0.00 | 0.00 |
| December | 40.65 | 0.00 | 40.65 | 96.36 | 20.27 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 51.98 | 2.77 | 49.21 | 134.82 | 7.90 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 40.65 | 0.00 | 40.65 | 96.36 | 1.35 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.83 | 15.54 | 62.29 | 212.36 | 20.27 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N N2A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 41.84 | 0.00 | 41.84 | 100.39 | 17.06 | 0.00 | 0.00 | 0.00 |
| February | 44.64 | 0.00 | 44.64 | 113.52 | 11.44 | 0.00 | 0.00 | 0.00 |
| March | 45.85 | 0.01 | 45.84 | 124.84 | 6.09 | 0.00 | 0.00 | 0.00 |
| April | 50.50 | 0.95 | 49.54 | 145.32 | 1.35 | 0.00 | 0.00 | 0.00 |
| May | 64.09 | 6.99 | 57.10 | 182.42 | 2.70 | 0.00 | 0.00 | 0.00 |
| June | 77.83 | 15.54 | 62.29 | 212.35 | 2.98 | 0.00 | 0.00 | 0.00 |
| July | 66.90 | 6.81 | 60.09 | 165.77 | 6.65 | 0.00 | 0.00 | 0.00 |
| August | 55.69 | 2.74 | 52.95 | 139.46 | 4.65 | 0.00 | 0.00 | 0.00 |
| September | 47.14 | 0.07 | 47.07 | 123.63 | 4.67 | 0.00 | 0.00 | 0.00 |
| October | 45.34 | 0.00 | 45.34 | 109.37 | 6.66 | 0.00 | 0.00 | 0.00 |
| November | 42.90 | 0.00 | 42.90 | 103.68 | 10.10 | 0.00 | 0.00 | 0.00 |
| December | 40.65 | 0.00 | 40.65 | 96.33 | 20.26 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 51.98 | 2.77 | 49.21 | 134.80 | 7.89 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 40.65 | 0.00 | 40.65 | 96.33 | 1.35 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.83 | 15.54 | 62.29 | 212.35 | 20.26 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S S1A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 109.81 | 45.24 | 64.57 | 243.35 | 16.39 | 0.00 | 0.00 | 0.00 |
| February | 94.92 | 31.52 | 63.40 | 226.77 | 10.76 | 0.00 | 0.00 | 0.00 |
| March | 64.43 | 8.88 | 55.55 | 172.57 | 5.38 | 0.00 | 0.00 | 0.00 |
| April | 48.48 | 0.51 | 47.97 | 143.20 | 1.33 | 0.00 | 0.00 | 0.00 |
| May | 47.90 | 0.00 | 47.90 | 145.18 | 2.55 | 0.00 | 0.00 | 0.00 |
| June | 47.72 | 0.00 | 47.72 | 143.08 | 2.83 | 0.00 | 0.00 | 0.00 |
| July | 49.16 | 0.00 | 49.16 | 125.03 | 6.32 | 0.00 | 0.00 | 0.00 |
| August | 47.82 | 0.03 | 47.79 | 121.58 | 4.23 | 0.00 | 0.00 | 0.00 |
| September | 52.74 | 1.45 | 51.29 | 137.08 | 4.69 | 0.00 | 0.00 | 0.00 |
| October | 68.88 | 10.61 | 58.27 | 161.75 | 7.00 | 0.00 | 0.00 | 0.00 |
| November | 91.06 | 28.40 | 62.66 | 205.94 | 10.51 | 0.00 | 0.00 | 0.00 |
| December | 110.39 | 46.77 | 63.62 | 240.23 | 20.21 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 69.34 | 14.39 | 54.95 | 171.86 | 7.69 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 47.72 | 0.00 | 47.72 | 121.58 | 1.33 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 110.39 | 46.77 | 64.57 | 243.35 | 20.21 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S S2A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 109.81 | 45.24 | 64.57 | 243.33 | 16.38 | 0.00 | 0.00 | 0.00 |
| February | 94.92 | 31.52 | 63.40 | 226.74 | 10.75 | 0.00 | 0.00 | 0.00 |
| March | 64.43 | 8.88 | 55.55 | 172.57 | 5.37 | 0.00 | 0.00 | 0.00 |
| April | 48.48 | 0.51 | 47.97 | 143.20 | 1.33 | 0.00 | 0.00 | 0.00 |
| May | 47.90 | 0.00 | 47.90 | 145.18 | 2.55 | 0.00 | 0.00 | 0.00 |
| June | 47.72 | 0.00 | 47.72 | 143.07 | 2.83 | 0.00 | 0.00 | 0.00 |
| July | 49.16 | 0.00 | 49.16 | 125.02 | 6.31 | 0.00 | 0.00 | 0.00 |
| August | 47.82 | 0.03 | 47.79 | 121.56 | 4.23 | 0.00 | 0.00 | 0.00 |
| September | 52.74 | 1.45 | 51.29 | 137.07 | 4.68 | 0.00 | 0.00 | 0.00 |
| October | 68.88 | 10.61 | 58.27 | 161.74 | 6.99 | 0.00 | 0.00 | 0.00 |
| November | 91.06 | 28.40 | 62.66 | 205.93 | 10.51 | 0.00 | 0.00 | 0.00 |
| December | 110.39 | 46.77 | 63.62 | 240.20 | 20.20 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 69.34 | 14.39 | 54.95 | 171.85 | 7.68 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 47.72 | 0.00 | 47.72 | 121.56 | 1.33 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 110.39 | 46.77 | 64.57 | 243.33 | 20.20 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW14
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 12.77 | 4.32 | 8.44 | 25.80 | 4.13 | 335.83 | 0.00 | 0.00 |
| February | 14.40 | 5.26 | 9.15 | 30.19 | 3.12 | 295.17 | 0.00 | 0.00 |
| March | 15.76 | 6.16 | 9.60 | 33.93 | 2.12 | 263.00 | 0.00 | 0.00 |
| April | 15.92 | 6.08 | 9.83 | 35.23 | 0.83 | 86.83 | 0.00 | 0.00 |
| May | 13.67 | 4.14 | 9.54 | 31.47 | 1.24 | 148.67 | 0.00 | 0.00 |
| June | 14.58 | 4.80 | 9.77 | 32.98 | 1.35 | 151.83 | 0.00 | 0.00 |
| July | 12.45 | 2.80 | 9.66 | 26.47 | 2.39 | 289.17 | 0.00 | 0.00 |
| August | 13.69 | 4.02 | 9.67 | 28.60 | 2.05 | 283.67 | 0.00 | 0.00 |
| September | 12.87 | 3.51 | 9.36 | 27.69 | 2.01 | 257.67 | 0.00 | 0.00 |
| October | 12.07 | 3.10 | 8.97 | 24.54 | 2.60 | 320.33 | 0.00 | 0.00 |
| November | 11.70 | 3.24 | 8.45 | 23.79 | 3.11 | 319.00 | 0.00 | 0.00 |
| December | 11.95 | 3.84 | 8.11 | 24.01 | 4.78 | 367.67 | 0.00 | 0.00 |
| Annual Sum or Average | 13.47 | 4.26 | 9.21 | 28.70 | 2.48 | 3118.83 | 0.00 | 0.00 |
| Minimum of Months | 11.70 | 2.80 | 8.11 | 23.79 | 0.83 | 86.83 | 0.00 | 0.00 |
| Maximum of Months | 15.92 | 6.16 | 9.83 | 35.23 | 4.78 | 367.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ENTRANCE DOOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 38.02 | 12.87 | 25.15 | 73.63 | 16.66 | 127.50 | 0.00 | 0.00 |
| February | 42.90 | 15.66 | 27.24 | 86.03 | 13.94 | 100.50 | 0.00 | 0.00 |
| March | 46.93 | 18.34 | 28.58 | 96.71 | 10.93 | 116.67 | 0.00 | 0.00 |
| April | 47.40 | 18.12 | 29.29 | 99.60 | 6.25 | 175.33 | 0.00 | 0.00 |
| May | 40.73 | 12.32 | 28.41 | 87.78 | 6.91 | 238.17 | 0.00 | 0.00 |
| June | 43.41 | 14.31 | 29.10 | 92.89 | 7.59 | 219.33 | 0.00 | 0.00 |
| July | 37.09 | 8.33 | 28.76 | 74.75 | 10.74 | 163.67 | 0.00 | 0.00 |
| August | 40.77 | 11.97 | 28.80 | 80.89 | 9.96 | 232.67 | 0.00 | 0.00 |
| September | 38.33 | 10.46 | 27.87 | 78.31 | 9.63 | 208.33 | 0.00 | 0.00 |
| October | 35.96 | 9.23 | 26.73 | 69.49 | 11.64 | 206.00 | 0.00 | 0.00 |
| November | 34.83 | 9.66 | 25.18 | 67.56 | 13.24 | 169.67 | 0.00 | 0.00 |
| December | 35.58 | 11.43 | 24.15 | 68.46 | 18.45 | 149.00 | 0.00 | 0.00 |
| Annual Sum or Average | 40.13 | 12.70 | 27.44 | 81.27 | 11.33 | 2106.83 | 0.00 | 0.00 |
| Minimum of Months | 34.83 | 8.33 | 24.15 | 67.56 | 6.25 | 100.50 | 0.00 | 0.00 |
| Maximum of Months | 47.40 | 18.34 | 29.29 | 99.60 | 18.45 | 238.17 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW14
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 12.77 | 4.32 | 8.44 | 26.25 | 4.11 | 320.50 | 0.00 | 0.00 |
| February | 14.40 | 5.26 | 9.15 | 30.74 | 3.13 | 273.67 | 0.00 | 0.00 |
| March | 15.76 | 6.16 | 9.60 | 34.60 | 2.06 | 232.83 | 0.00 | 0.00 |
| April | 15.92 | 6.08 | 9.83 | 36.11 | 0.81 | 79.67 | 0.00 | 0.00 |
| May | 13.67 | 4.14 | 9.54 | 32.33 | 1.16 | 139.33 | 0.00 | 0.00 |
| June | 14.58 | 4.80 | 9.77 | 33.84 | 1.25 | 135.33 | 0.00 | 0.00 |
| July | 12.45 | 2.80 | 9.66 | 27.08 | 2.28 | 270.50 | 0.00 | 0.00 |
| August | 13.69 | 4.02 | 9.67 | 29.18 | 1.93 | 239.67 | 0.00 | 0.00 |
| September | 12.87 | 3.51 | 9.36 | 28.33 | 1.88 | 231.17 | 0.00 | 0.00 |
| October | 12.07 | 3.10 | 8.97 | 25.07 | 2.48 | 303.00 | 0.00 | 0.00 |
| November | 11.70 | 3.24 | 8.45 | 24.28 | 3.03 | 299.83 | 0.00 | 0.00 |
| December | 11.95 | 3.84 | 8.11 | 24.40 | 4.77 | 344.33 | 0.00 | 0.00 |
| Annual Sum or Average | 13.47 | 4.26 | 9.21 | 29.33 | 2.41 | 2869.83 | 0.00 | 0.00 |
| Minimum of Months | 11.70 | 2.80 | 8.11 | 24.28 | 0.81 | 79.67 | 0.00 | 0.00 |
| Maximum of Months | 15.92 | 6.16 | 9.83 | 36.11 | 4.77 | 344.33 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S SWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.294108E+09 | 0.121162E+09 | 0.172946E+09 | 0.654523E+09 | 51373640.00 |
| February | 0.229638E+09 | 76259171.80 | 0.153379E+09 | 0.549292E+09 | 33061224.95 |
| March | 0.172569E+09 | 23772949.97 | 0.148796E+09 | 0.459196E+09 | 20081008.09 |
| April | 0.125658E+09 | 1329232.19 | 0.124329E+09 | 0.363345E+09 | 4958853.22 |
| May | 0.128288E+09 | 0.00 | 0.128288E+09 | 0.381973E+09 | 9287693.13 |
| June | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.363174E+09 | 9691076.23 |
| July | 0.131680E+09 | 0.00 | 0.131680E+09 | 0.331753E+09 | 22082208.05 |
| August | 0.128072E+09 | 78684.75 | 0.127993E+09 | 0.320400E+09 | 15724249.02 |
| September | 0.136697E+09 | 3766062.87 | 0.132931E+09 | 0.352049E+09 | 16133426.27 |
| October | 0.184496E+09 | 28412967.82 | 0.156083E+09 | 0.433273E+09 | 23613812.00 |
| November | 0.236031E+09 | 73614914.47 | 0.162416E+09 | 0.535077E+09 | 32865835.90 |
| December | 0.295679E+09 | 0.125273E+09 | 0.170406E+09 | 0.646109E+09 | 61454398.74 |
| Annual Sum or Average | 0.218662E+10 | 0.453669E+09 | 0.173295E+10 | 0.539016E+10 | 0.300327E+09 |
| Minimum of Months | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.320400E+09 | 4958853.22 |
| Maximum of Months | 0.295679E+09 | 0.125273E+09 | 0.172946E+09 | 0.654523E+09 | 61454398.74 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 W SWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.144440E+09 | 51007891.94 | 93431797.15 | 0.318282E+09 | 36425739.52 |
| February | 0.142919E+09 | 50583646.60 | 92335829.04 | 0.324455E+09 | 23487040.78 |
| March | 0.177465E+09 | 70161407.30 | 0.107304E+09 | 0.413741E+09 | 14611448.46 |
| April | 0.172262E+09 | 65844908.15 | 0.106417E+09 | 0.415225E+09 | 3360773.40 |
| May | 0.151639E+09 | 44914133.92 | 0.106725E+09 | 0.384618E+09 | 6005001.60 |
| June | 0.158946E+09 | 54734314.60 | 0.104212E+09 | 0.393777E+09 | 6284833.99 |
| July | 0.140175E+09 | 33089957.42 | 0.107085E+09 | 0.326832E+09 | 14349049.30 |
| August | 0.152481E+09 | 45211569.73 | 0.107270E+09 | 0.345259E+09 | 10184149.99 |
| September | 0.137950E+09 | 38170678.12 | 99779476.24 | 0.323126E+09 | 10411312.91 |
| October | 0.134002E+09 | 34526987.88 | 99475174.21 | 0.297825E+09 | 15367260.61 |
| November | 0.126282E+09 | 34315245.16 | 91966963.64 | 0.280443E+09 | 21874156.68 |
| December | 0.133808E+09 | 43820569.77 | 89987146.69 | 0.293409E+09 | 42351243.67 |
| Annual Sum or Average | 0.177237E+10 | 0.566381E+09 | 0.120599E+10 | 0.411699E+10 | 0.204712E+09 |
| Minimum of Months | 0.126282E+09 | 33089957.42 | 89987146.69 | 0.280443E+09 | 3360773.40 |
| Maximum of Months | 0.177465E+09 | 70161407.30 | 0.107304E+09 | 0.415225E+09 | 42351243.67 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 W NWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.144440E+09 | 51007891.94 | 93431797.15 | 0.322414E+09 | 34324591.74 |
| February | 0.142919E+09 | 50583646.60 | 92335829.04 | 0.327808E+09 | 22042069.74 |
| March | 0.177465E+09 | 70161407.30 | 0.107304E+09 | 0.415494E+09 | 14001466.04 |
| April | 0.172262E+09 | 65844908.15 | 0.106417E+09 | 0.414836E+09 | 3395611.91 |
| May | 0.151639E+09 | 44914133.92 | 0.106725E+09 | 0.382775E+09 | 6281421.60 |
| June | 0.158946E+09 | 54734314.60 | 0.104212E+09 | 0.390508E+09 | 6696403.91 |
| July | 0.140175E+09 | 33089957.42 | 0.107085E+09 | 0.325147E+09 | 14939379.17 |
| August | 0.152481E+09 | 45211569.73 | 0.107270E+09 | 0.344248E+09 | 10447180.26 |
| September | 0.137950E+09 | 38170678.12 | 99779476.24 | 0.323538E+09 | 10358774.45 |
| October | 0.134002E+09 | 34526987.88 | 99475174.21 | 0.299587E+09 | 14746519.10 |
| November | 0.126282E+09 | 34315245.16 | 91966963.64 | 0.283709E+09 | 20643662.82 |
| December | 0.133808E+09 | 43820569.77 | 89987146.69 | 0.297685E+09 | 40119160.24 |
| Annual Sum or Average | 0.177237E+10 | 0.566381E+09 | 0.120599E+10 | 0.412775E+10 | 0.197996E+09 |
| Minimum of Months | 0.126282E+09 | 33089957.42 | 89987146.69 | 0.283709E+09 | 3395611.91 |
| Maximum of Months | 0.177465E+09 | 70161407.30 | 0.107304E+09 | 0.415494E+09 | 40119160.24 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N NWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.112074E+09 | 0.00 | 0.112074E+09 | 0.267502E+09 | 52531458.76 |
| February | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.272594E+09 | 34100877.52 |
| March | 0.122797E+09 | 21683.77 | 0.122775E+09 | 0.330581E+09 | 21547611.68 |
| April | 0.130886E+09 | 2466740.50 | 0.128420E+09 | 0.370478E+09 | 5235203.00 |
| May | 0.171666E+09 | 18735234.68 | 0.152931E+09 | 0.484170E+09 | 9900147.08 |
| June | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.546419E+09 | 10370765.30 |
| July | 0.179198E+09 | 18240175.10 | 0.160958E+09 | 0.442904E+09 | 23158749.41 |
| August | 0.149152E+09 | 7326383.82 | 0.141826E+09 | 0.369666E+09 | 16896922.54 |
| September | 0.122176E+09 | 168559.27 | 0.122007E+09 | 0.316785E+09 | 16107131.71 |
| October | 0.121434E+09 | 0.00 | 0.121434E+09 | 0.290944E+09 | 22550432.80 |
| November | 0.111197E+09 | 0.00 | 0.111197E+09 | 0.266959E+09 | 31490510.11 |
| December | 0.108878E+09 | 0.00 | 0.108878E+09 | 0.256388E+09 | 61191001.55 |
| Annual Sum or Average | 0.163917E+10 | 87245866.33 | 0.155193E+10 | 0.421539E+10 | 0.305081E+09 |
| Minimum of Months | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.256388E+09 | 5235203.00 |
| Maximum of Months | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.546419E+09 | 61191001.55 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S SEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.294108E+09 | 0.121162E+09 | 0.172946E+09 | 0.612639E+09 | 0.115953E+09 |
| February | 0.229638E+09 | 76259171.80 | 0.153379E+09 | 0.510917E+09 | 89945590.48 |
| March | 0.172569E+09 | 23772949.97 | 0.148796E+09 | 0.416133E+09 | 80813473.34 |
| April | 0.125658E+09 | 1329232.19 | 0.124329E+09 | 0.300044E+09 | 51748177.69 |
| May | 0.128288E+09 | 0.00 | 0.128288E+09 | 0.314026E+09 | 55096637.79 |
| June | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.303469E+09 | 56355038.59 |
| July | 0.131680E+09 | 0.00 | 0.131680E+09 | 0.280707E+09 | 80093957.21 |
| August | 0.128072E+09 | 78684.75 | 0.127993E+09 | 0.276251E+09 | 72560979.67 |
| September | 0.136697E+09 | 3766062.87 | 0.132931E+09 | 0.303574E+09 | 71270169.53 |
| October | 0.184496E+09 | 28412967.82 | 0.156083E+09 | 0.388318E+09 | 85689186.12 |
| November | 0.236031E+09 | 73614914.47 | 0.162416E+09 | 0.493010E+09 | 90901458.81 |
| December | 0.295679E+09 | 0.125273E+09 | 0.170406E+09 | 0.608616E+09 | 0.122553E+09 |
| Annual Sum or Average | 0.218662E+10 | 0.453669E+09 | 0.173295E+10 | 0.480770E+10 | 0.972981E+09 |
| Minimum of Months | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.276251E+09 | 51748177.69 |
| Maximum of Months | 0.295679E+09 | 0.125273E+09 | 0.172946E+09 | 0.612639E+09 | 0.122553E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 E SEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.142511E+09 | 48248987.90 | 94261877.90 | 0.283172E+09 | 75845731.62 |
| February | 0.145223E+09 | 52997774.44 | 92224754.87 | 0.300942E+09 | 58218530.97 |
| March | 0.175875E+09 | 68744128.74 | 0.107131E+09 | 0.379661E+09 | 51576661.05 |
| April | 0.171933E+09 | 65708941.82 | 0.106224E+09 | 0.375633E+09 | 33108899.03 |
| May | 0.152642E+09 | 46161163.88 | 0.106480E+09 | 0.344075E+09 | 35379132.88 |
| June | 0.157442E+09 | 51884356.97 | 0.105557E+09 | 0.353815E+09 | 36322450.26 |
| July | 0.139012E+09 | 31214610.43 | 0.107797E+09 | 0.290178E+09 | 50895145.97 |
| August | 0.152812E+09 | 44867602.37 | 0.107945E+09 | 0.318970E+09 | 46508658.48 |
| September | 0.139033E+09 | 37944930.92 | 0.101088E+09 | 0.294702E+09 | 45364628.54 |
| October | 0.134781E+09 | 34603181.21 | 0.100178E+09 | 0.270651E+09 | 55646410.73 |
| November | 0.126340E+09 | 35025750.75 | 91314286.72 | 0.253285E+09 | 59671476.44 |
| December | 0.133345E+09 | 42828667.37 | 90516747.55 | 0.264389E+09 | 80437075.25 |
| Annual Sum or Average | 0.177095E+10 | 0.560230E+09 | 0.121072E+10 | 0.372948E+10 | 0.628975E+09 |
| Minimum of Months | 0.126340E+09 | 31214610.43 | 90516747.55 | 0.253285E+09 | 33108899.03 |
| Maximum of Months | 0.175875E+09 | 68744128.74 | 0.107945E+09 | 0.379661E+09 | 80437075.25 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 E NEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.142511E+09 | 48248987.90 | 94261877.90 | 0.314456E+09 | 31332412.80 |
| February | 0.145223E+09 | 52997774.44 | 92224754.87 | 0.330048E+09 | 19812161.91 |
| March | 0.175875E+09 | 68744128.74 | 0.107131E+09 | 0.411685E+09 | 11979707.74 |
| April | 0.171933E+09 | 65708941.82 | 0.106224E+09 | 0.418469E+09 | 3146608.75 |
| May | 0.152642E+09 | 46161163.88 | 0.106480E+09 | 0.387819E+09 | 6381285.62 |
| June | 0.157442E+09 | 51884356.97 | 0.105557E+09 | 0.389639E+09 | 6718188.59 |
| July | 0.139012E+09 | 31214610.43 | 0.107797E+09 | 0.323266E+09 | 14973113.93 |
| August | 0.152812E+09 | 44867602.37 | 0.107945E+09 | 0.347354E+09 | 10815264.91 |
| September | 0.139033E+09 | 37944930.92 | 0.101088E+09 | 0.328140E+09 | 10320529.60 |
| October | 0.134781E+09 | 34603181.21 | 0.100178E+09 | 0.302512E+09 | 14506256.82 |
| November | 0.126340E+09 | 35025750.75 | 91314286.72 | 0.283874E+09 | 20021530.84 |
| December | 0.133345E+09 | 42828667.37 | 90516747.55 | 0.292600E+09 | 37639663.47 |
| Annual Sum or Average | 0.177095E+10 | 0.560230E+09 | 0.121072E+10 | 0.412986E+10 | 0.187647E+09 |
| Minimum of Months | 0.126340E+09 | 31214610.43 | 90516747.55 | 0.283874E+09 | 3146608.75 |
| Maximum of Months | 0.175875E+09 | 68744128.74 | 0.107945E+09 | 0.418469E+09 | 37639663.47 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N NEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.112074E+09 | 0.00 | 0.112074E+09 | 0.266646E+09 | 52184728.28 |
| February | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.271873E+09 | 33807710.08 |
| March | 0.122797E+09 | 21683.77 | 0.122775E+09 | 0.330353E+09 | 21062905.82 |
| April | 0.130886E+09 | 2466740.50 | 0.128420E+09 | 0.370305E+09 | 5112625.96 |
| May | 0.171666E+09 | 18735234.68 | 0.152931E+09 | 0.483820E+09 | 9790510.57 |
| June | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.545995E+09 | 10273145.97 |
| July | 0.179198E+09 | 18240175.10 | 0.160958E+09 | 0.442462E+09 | 22926946.22 |
| August | 0.149152E+09 | 7326383.82 | 0.141826E+09 | 0.369113E+09 | 16708877.06 |
| September | 0.122176E+09 | 168559.27 | 0.122007E+09 | 0.316288E+09 | 15973932.20 |
| October | 0.121434E+09 | 0.00 | 0.121434E+09 | 0.290628E+09 | 22328203.95 |
| November | 0.111197E+09 | 0.00 | 0.111197E+09 | 0.266540E+09 | 31322955.15 |
| December | 0.108878E+09 | 0.00 | 0.108878E+09 | 0.255672E+09 | 60855897.50 |
| Annual Sum or Average | 0.163917E+10 | 87245866.33 | 0.155193E+10 | 0.420970E+10 | 0.302348E+09 |
| Minimum of Months | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.255672E+09 | 5112625.96 |
| Maximum of Months | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.545995E+09 | 60855897.50 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N N1A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.112074E+09 | 0.00 | 0.112074E+09 | 0.272648E+09 | 50193636.52 |
| February | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.278145E+09 | 31727504.04 |
| March | 0.122797E+09 | 21683.77 | 0.122775E+09 | 0.338213E+09 | 19217307.52 |
| April | 0.130886E+09 | 2466740.50 | 0.128420E+09 | 0.379804E+09 | 4492150.03 |
| May | 0.171666E+09 | 18735234.68 | 0.152931E+09 | 0.492532E+09 | 8819113.24 |
| June | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.554763E+09 | 9229786.49 |
| July | 0.179198E+09 | 18240175.10 | 0.160958E+09 | 0.449167E+09 | 20980607.69 |
| August | 0.149152E+09 | 7326383.82 | 0.141826E+09 | 0.376576E+09 | 15137428.88 |
| September | 0.122176E+09 | 168559.27 | 0.122007E+09 | 0.323510E+09 | 14279030.84 |
| October | 0.121434E+09 | 0.00 | 0.121434E+09 | 0.296472E+09 | 20525013.38 |
| November | 0.111197E+09 | 0.00 | 0.111197E+09 | 0.272103E+09 | 29550458.43 |
| December | 0.108878E+09 | 0.00 | 0.108878E+09 | 0.261159E+09 | 58991300.66 |
| Annual Sum or Average | 0.163917E+10 | 87245866.33 | 0.155193E+10 | 0.429509E+10 | 0.283143E+09 |
| Minimum of Months | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.261159E+09 | 4492150.03 |
| Maximum of Months | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.554763E+09 | 58991300.66 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N N2A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.112074E+09 | 0.00 | 0.112074E+09 | 0.272609E+09 | 50188863.29 |
| February | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.278114E+09 | 31721214.27 |
| March | 0.122797E+09 | 21683.77 | 0.122775E+09 | 0.338208E+09 | 19203574.62 |
| April | 0.130886E+09 | 2466740.50 | 0.128420E+09 | 0.379797E+09 | 4488739.70 |
| May | 0.171666E+09 | 18735234.68 | 0.152931E+09 | 0.492518E+09 | 8815400.28 |
| June | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.554748E+09 | 9229271.68 |
| July | 0.179198E+09 | 18240175.10 | 0.160958E+09 | 0.449150E+09 | 20974736.79 |
| August | 0.149152E+09 | 7326383.82 | 0.141826E+09 | 0.376554E+09 | 15134457.11 |
| September | 0.122176E+09 | 168559.27 | 0.122007E+09 | 0.323489E+09 | 14277637.01 |
| October | 0.121434E+09 | 0.00 | 0.121434E+09 | 0.296461E+09 | 20519092.49 |
| November | 0.111197E+09 | 0.00 | 0.111197E+09 | 0.272086E+09 | 29548262.78 |
| December | 0.108878E+09 | 0.00 | 0.108878E+09 | 0.261128E+09 | 58984252.52 |
| Annual Sum or Average | 0.163917E+10 | 87245866.33 | 0.155193E+10 | 0.429486E+10 | 0.283086E+09 |
| Minimum of Months | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.261128E+09 | 4488739.70 |
| Maximum of Months | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.554748E+09 | 58984252.52 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S S1A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.294108E+09 | 0.121162E+09 | 0.172946E+09 | 0.659086E+09 | 49410047.71 |
| February | 0.229638E+09 | 76259171.80 | 0.153379E+09 | 0.554496E+09 | 31069212.75 |
| March | 0.172569E+09 | 23772949.97 | 0.148796E+09 | 0.466878E+09 | 18112249.99 |
| April | 0.125658E+09 | 1329232.19 | 0.124329E+09 | 0.372922E+09 | 4359860.55 |
| May | 0.128288E+09 | 0.00 | 0.128288E+09 | 0.390653E+09 | 8236038.68 |
| June | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.372236E+09 | 8615450.90 |
| July | 0.131680E+09 | 0.00 | 0.131680E+09 | 0.338200E+09 | 19904221.41 |
| August | 0.128072E+09 | 78684.75 | 0.127993E+09 | 0.327609E+09 | 14054799.59 |
| September | 0.136697E+09 | 3766062.87 | 0.132931E+09 | 0.358698E+09 | 14397648.84 |
| October | 0.184496E+09 | 28412967.82 | 0.156083E+09 | 0.438518E+09 | 21771996.81 |
| November | 0.236031E+09 | 73614914.47 | 0.162416E+09 | 0.539771E+09 | 31207188.23 |
| December | 0.295679E+09 | 0.125273E+09 | 0.170406E+09 | 0.650247E+09 | 59589016.08 |
| Annual Sum or Average | 0.218662E+10 | 0.453669E+09 | 0.173295E+10 | 0.546932E+10 | 0.280728E+09 |
| Minimum of Months | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.327609E+09 | 4359860.55 |
| Maximum of Months | 0.295679E+09 | 0.125273E+09 | 0.172946E+09 | 0.659086E+09 | 59589016.08 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S S2A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.294108E+09 | 0.121162E+09 | 0.172946E+09 | 0.656558E+09 | 51442669.58 |
| February | 0.229638E+09 | 76259171.80 | 0.153379E+09 | 0.552237E+09 | 32758815.92 |
| March | 0.172569E+09 | 23772949.97 | 0.148796E+09 | 0.464133E+09 | 19537646.43 |
| April | 0.125658E+09 | 1329232.19 | 0.124329E+09 | 0.369120E+09 | 4862664.71 |
| May | 0.128288E+09 | 0.00 | 0.128288E+09 | 0.386926E+09 | 9046234.94 |
| June | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.368780E+09 | 9433957.62 |
| July | 0.131680E+09 | 0.00 | 0.131680E+09 | 0.335479E+09 | 21532738.42 |
| August | 0.128072E+09 | 78684.75 | 0.127993E+09 | 0.324688E+09 | 15353019.90 |
| September | 0.136697E+09 | 3766062.87 | 0.132931E+09 | 0.355906E+09 | 15735286.61 |
| October | 0.184496E+09 | 28412967.82 | 0.156083E+09 | 0.435996E+09 | 23637135.44 |
| November | 0.236031E+09 | 73614914.47 | 0.162416E+09 | 0.537417E+09 | 32975228.54 |
| December | 0.295679E+09 | 0.125273E+09 | 0.170406E+09 | 0.648068E+09 | 61495184.60 |
| Annual Sum or Average | 0.218662E+10 | 0.453669E+09 | 0.173295E+10 | 0.543531E+10 | 0.297811E+09 |
| Minimum of Months | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.324688E+09 | 4862664.71 |
| Maximum of Months | 0.295679E+09 | 0.125273E+09 | 0.172946E+09 | 0.656558E+09 | 61495184.60 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S SWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.294108E+09 | 0.121162E+09 | 0.172946E+09 | 0.657919E+09 | 46202953.60 |
| February | 0.229638E+09 | 76259171.80 | 0.153379E+09 | 0.553332E+09 | 28290387.80 |
| March | 0.172569E+09 | 23772949.97 | 0.148796E+09 | 0.465564E+09 | 16153737.27 |
| April | 0.125658E+09 | 1329232.19 | 0.124329E+09 | 0.373011E+09 | 3796109.91 |
| May | 0.128288E+09 | 0.00 | 0.128288E+09 | 0.391712E+09 | 7164925.36 |
| June | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.373467E+09 | 7631958.33 |
| July | 0.131680E+09 | 0.00 | 0.131680E+09 | 0.338539E+09 | 17732074.41 |
| August | 0.128072E+09 | 78684.75 | 0.127993E+09 | 0.328661E+09 | 12035384.23 |
| September | 0.136697E+09 | 3766062.87 | 0.132931E+09 | 0.359034E+09 | 12580597.80 |
| October | 0.184496E+09 | 28412967.82 | 0.156083E+09 | 0.437821E+09 | 19404643.00 |
| November | 0.236031E+09 | 73614914.47 | 0.162416E+09 | 0.539048E+09 | 28464520.02 |
| December | 0.295679E+09 | 0.125273E+09 | 0.170406E+09 | 0.649467E+09 | 56215844.85 |
| Annual Sum or Average | 0.218662E+10 | 0.453669E+09 | 0.173295E+10 | 0.546758E+10 | 0.255673E+09 |
| Minimum of Months | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.328661E+09 | 3796109.91 |
| Maximum of Months | 0.295679E+09 | 0.125273E+09 | 0.172946E+09 | 0.657919E+09 | 56215844.85 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 W SWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.144440E+09 | 51007891.94 | 93431797.15 | 0.320769E+09 | 32899973.13 |
| February | 0.142919E+09 | 50583646.60 | 92335829.04 | 0.327006E+09 | 20237366.29 |
| March | 0.177465E+09 | 70161407.30 | 0.107304E+09 | 0.416945E+09 | 12057353.66 |
| April | 0.172262E+09 | 65844908.15 | 0.106417E+09 | 0.420110E+09 | 2546964.01 |
| May | 0.151639E+09 | 44914133.92 | 0.106725E+09 | 0.390063E+09 | 4628006.44 |
| June | 0.158946E+09 | 54734314.60 | 0.104212E+09 | 0.399509E+09 | 4965978.19 |
| July | 0.140175E+09 | 33089957.42 | 0.107085E+09 | 0.330596E+09 | 11538282.44 |
| August | 0.152481E+09 | 45211569.73 | 0.107270E+09 | 0.349823E+09 | 7814640.34 |
| September | 0.137950E+09 | 38170678.12 | 99779476.24 | 0.327248E+09 | 8133427.36 |
| October | 0.134002E+09 | 34526987.88 | 99475174.21 | 0.300777E+09 | 12561746.68 |
| November | 0.126282E+09 | 34315245.16 | 91966963.64 | 0.283311E+09 | 18851842.35 |
| December | 0.133808E+09 | 43820569.77 | 89987146.69 | 0.295940E+09 | 38663690.58 |
| Annual Sum or Average | 0.177237E+10 | 0.566381E+09 | 0.120599E+10 | 0.416210E+10 | 0.174899E+09 |
| Minimum of Months | 0.126282E+09 | 33089957.42 | 89987146.69 | 0.283311E+09 | 2546964.01 |
| Maximum of Months | 0.177465E+09 | 70161407.30 | 0.107304E+09 | 0.420110E+09 | 38663690.58 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 W NWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.144440E+09 | 51007891.94 | 93431797.15 | 0.324739E+09 | 31322813.10 |
| February | 0.142919E+09 | 50583646.60 | 92335829.04 | 0.330196E+09 | 19222314.14 |
| March | 0.177465E+09 | 70161407.30 | 0.107304E+09 | 0.418570E+09 | 11631424.61 |
| April | 0.172262E+09 | 65844908.15 | 0.106417E+09 | 0.419824E+09 | 2550648.34 |
| May | 0.151639E+09 | 44914133.92 | 0.106725E+09 | 0.388489E+09 | 4808675.51 |
| June | 0.158946E+09 | 54734314.60 | 0.104212E+09 | 0.396664E+09 | 5235605.98 |
| July | 0.140175E+09 | 33089957.42 | 0.107085E+09 | 0.329109E+09 | 11937872.59 |
| August | 0.152481E+09 | 45211569.73 | 0.107270E+09 | 0.348946E+09 | 7962540.58 |
| September | 0.137950E+09 | 38170678.12 | 99779476.24 | 0.327687E+09 | 8072227.93 |
| October | 0.134002E+09 | 34526987.88 | 99475174.21 | 0.302441E+09 | 12085672.18 |
| November | 0.126282E+09 | 34315245.16 | 91966963.64 | 0.286389E+09 | 17932623.56 |
| December | 0.133808E+09 | 43820569.77 | 89987146.69 | 0.300104E+09 | 36993998.78 |
| Annual Sum or Average | 0.177237E+10 | 0.566381E+09 | 0.120599E+10 | 0.417316E+10 | 0.169756E+09 |
| Minimum of Months | 0.126282E+09 | 33089957.42 | 89987146.69 | 0.286389E+09 | 2550648.34 |
| Maximum of Months | 0.177465E+09 | 70161407.30 | 0.107304E+09 | 0.419824E+09 | 36993998.78 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N NWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.112074E+09 | 0.00 | 0.112074E+09 | 0.272095E+09 | 47791287.98 |
| February | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.277267E+09 | 29685398.21 |
| March | 0.122797E+09 | 21683.77 | 0.122775E+09 | 0.336768E+09 | 17826690.51 |
| April | 0.130886E+09 | 2466740.50 | 0.128420E+09 | 0.379141E+09 | 3900475.59 |
| May | 0.171666E+09 | 18735234.68 | 0.152931E+09 | 0.492808E+09 | 7650565.83 |
| June | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.555044E+09 | 8091540.28 |
| July | 0.179198E+09 | 18240175.10 | 0.160958E+09 | 0.448965E+09 | 18680952.83 |
| August | 0.149152E+09 | 7326383.82 | 0.141826E+09 | 0.377195E+09 | 13170158.41 |
| September | 0.122176E+09 | 168559.27 | 0.122007E+09 | 0.323862E+09 | 12519319.73 |
| October | 0.121434E+09 | 0.00 | 0.121434E+09 | 0.296178E+09 | 18383881.27 |
| November | 0.111197E+09 | 0.00 | 0.111197E+09 | 0.271844E+09 | 27207918.29 |
| December | 0.108878E+09 | 0.00 | 0.108878E+09 | 0.261061E+09 | 56228541.04 |
| Annual Sum or Average | 0.163917E+10 | 87245866.33 | 0.155193E+10 | 0.429223E+10 | 0.261137E+09 |
| Minimum of Months | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.261061E+09 | 3900475.59 |
| Maximum of Months | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.555044E+09 | 56228541.04 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S SEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.294108E+09 | 0.121162E+09 | 0.172946E+09 | 0.657009E+09 | 45780946.06 |
| February | 0.229638E+09 | 76259171.80 | 0.153379E+09 | 0.552579E+09 | 27988082.21 |
| March | 0.172569E+09 | 23772949.97 | 0.148796E+09 | 0.465459E+09 | 15768274.19 |
| April | 0.125658E+09 | 1329232.19 | 0.124329E+09 | 0.372935E+09 | 3727983.77 |
| May | 0.128288E+09 | 0.00 | 0.128288E+09 | 0.391391E+09 | 7062306.72 |
| June | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.373061E+09 | 7538917.73 |
| July | 0.131680E+09 | 0.00 | 0.131680E+09 | 0.338132E+09 | 17490513.99 |
| August | 0.128072E+09 | 78684.75 | 0.127993E+09 | 0.328109E+09 | 11855250.75 |
| September | 0.136697E+09 | 3766062.87 | 0.132931E+09 | 0.358577E+09 | 12441982.32 |
| October | 0.184496E+09 | 28412967.82 | 0.156083E+09 | 0.437494E+09 | 19176092.46 |
| November | 0.236031E+09 | 73614914.47 | 0.162416E+09 | 0.538611E+09 | 28262574.39 |
| December | 0.295679E+09 | 0.125273E+09 | 0.170406E+09 | 0.648642E+09 | 55828546.02 |
| Annual Sum or Average | 0.218662E+10 | 0.453669E+09 | 0.173295E+10 | 0.546200E+10 | 0.252921E+09 |
| Minimum of Months | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.328109E+09 | 3727983.77 |
| Maximum of Months | 0.295679E+09 | 0.125273E+09 | 0.172946E+09 | 0.657009E+09 | 55828546.02 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 E SEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.142511E+09 | 48248987.90 | 94261877.90 | 0.313075E+09 | 29870160.80 |
| February | 0.145223E+09 | 52997774.44 | 92224754.87 | 0.329621E+09 | 18026334.67 |
| March | 0.175875E+09 | 68744128.74 | 0.107131E+09 | 0.413573E+09 | 10029857.02 |
| April | 0.171933E+09 | 65708941.82 | 0.106224E+09 | 0.424263E+09 | 2389026.13 |
| May | 0.152642E+09 | 46161163.88 | 0.106480E+09 | 0.395187E+09 | 4765484.72 |
| June | 0.157442E+09 | 51884356.97 | 0.105557E+09 | 0.398350E+09 | 4967484.46 |
| July | 0.139012E+09 | 31214610.43 | 0.107797E+09 | 0.328826E+09 | 11662617.05 |
| August | 0.152812E+09 | 44867602.37 | 0.107945E+09 | 0.352870E+09 | 8266807.58 |
| September | 0.139033E+09 | 37944930.92 | 0.101088E+09 | 0.331957E+09 | 8092227.17 |
| October | 0.134781E+09 | 34603181.21 | 0.100178E+09 | 0.303848E+09 | 12377621.58 |
| November | 0.126340E+09 | 35025750.75 | 91314286.72 | 0.283552E+09 | 18292251.85 |
| December | 0.133345E+09 | 42828667.37 | 90516747.55 | 0.290990E+09 | 36225518.15 |
| Annual Sum or Average | 0.177095E+10 | 0.560230E+09 | 0.121072E+10 | 0.416611E+10 | 0.164965E+09 |
| Minimum of Months | 0.126340E+09 | 31214610.43 | 90516747.55 | 0.283552E+09 | 2389026.13 |
| Maximum of Months | 0.175875E+09 | 68744128.74 | 0.107945E+09 | 0.424263E+09 | 36225518.15 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 E NEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.142511E+09 | 48248987.90 | 94261877.90 | 0.317180E+09 | 28479351.32 |
| February | 0.145223E+09 | 52997774.44 | 92224754.87 | 0.332956E+09 | 17142995.63 |
| March | 0.175875E+09 | 68744128.74 | 0.107131E+09 | 0.415305E+09 | 9630661.46 |
| April | 0.171933E+09 | 65708941.82 | 0.106224E+09 | 0.423966E+09 | 2391623.58 |
| May | 0.152642E+09 | 46161163.88 | 0.106480E+09 | 0.393615E+09 | 4946739.72 |
| June | 0.157442E+09 | 51884356.97 | 0.105557E+09 | 0.395574E+09 | 5239308.02 |
| July | 0.139012E+09 | 31214610.43 | 0.107797E+09 | 0.327366E+09 | 12060652.01 |
| August | 0.152812E+09 | 44867602.37 | 0.107945E+09 | 0.352026E+09 | 8416012.70 |
| September | 0.139033E+09 | 37944930.92 | 0.101088E+09 | 0.332395E+09 | 8034877.89 |
| October | 0.134781E+09 | 34603181.21 | 0.100178E+09 | 0.305533E+09 | 11909555.15 |
| November | 0.126340E+09 | 35025750.75 | 91314286.72 | 0.286670E+09 | 17404038.55 |
| December | 0.133345E+09 | 42828667.37 | 90516747.55 | 0.295260E+09 | 34702394.09 |
| Annual Sum or Average | 0.177095E+10 | 0.560230E+09 | 0.121072E+10 | 0.417785E+10 | 0.160358E+09 |
| Minimum of Months | 0.126340E+09 | 31214610.43 | 90516747.55 | 0.286670E+09 | 2391623.58 |
| Maximum of Months | 0.175875E+09 | 68744128.74 | 0.107945E+09 | 0.423966E+09 | 34702394.09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N NEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.112074E+09 | 0.00 | 0.112074E+09 | 0.271065E+09 | 47470794.93 |
| February | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.276442E+09 | 29431669.55 |
| March | 0.122797E+09 | 21683.77 | 0.122775E+09 | 0.336590E+09 | 17427378.71 |
| April | 0.130886E+09 | 2466740.50 | 0.128420E+09 | 0.379026E+09 | 3820714.74 |
| May | 0.171666E+09 | 18735234.68 | 0.152931E+09 | 0.492486E+09 | 7543047.19 |
| June | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.554639E+09 | 7993499.84 |
| July | 0.179198E+09 | 18240175.10 | 0.160958E+09 | 0.448514E+09 | 18440970.17 |
| August | 0.149152E+09 | 7326383.82 | 0.141826E+09 | 0.376662E+09 | 12986888.23 |
| September | 0.122176E+09 | 168559.27 | 0.122007E+09 | 0.323394E+09 | 12384058.94 |
| October | 0.121434E+09 | 0.00 | 0.121434E+09 | 0.295851E+09 | 18166526.96 |
| November | 0.111197E+09 | 0.00 | 0.111197E+09 | 0.271387E+09 | 27021637.39 |
| December | 0.108878E+09 | 0.00 | 0.108878E+09 | 0.260183E+09 | 55920230.65 |
| Annual Sum or Average | 0.163917E+10 | 87245866.33 | 0.155193E+10 | 0.428624E+10 | 0.258607E+09 |
| Minimum of Months | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.260183E+09 | 3820714.74 |
| Maximum of Months | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.554639E+09 | 55920230.65 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N N1A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.112074E+09 | 0.00 | 0.112074E+09 | 0.276764E+09 | 46223865.68 |
| February | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.282426E+09 | 28124281.03 |
| March | 0.122797E+09 | 21683.77 | 0.122775E+09 | 0.343910E+09 | 16259342.68 |
| April | 0.130886E+09 | 2466740.50 | 0.128420E+09 | 0.387503E+09 | 3498860.21 |
| May | 0.171666E+09 | 18735234.68 | 0.152931E+09 | 0.500033E+09 | 6954698.13 |
| June | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.562131E+09 | 7405111.26 |
| July | 0.179198E+09 | 18240175.10 | 0.160958E+09 | 0.454212E+09 | 17334176.31 |
| August | 0.149152E+09 | 7326383.82 | 0.141826E+09 | 0.383016E+09 | 12180919.78 |
| September | 0.122176E+09 | 168559.27 | 0.122007E+09 | 0.329583E+09 | 11473610.82 |
| October | 0.121434E+09 | 0.00 | 0.121434E+09 | 0.301082E+09 | 17086279.57 |
| November | 0.111197E+09 | 0.00 | 0.111197E+09 | 0.276379E+09 | 25962857.09 |
| December | 0.108878E+09 | 0.00 | 0.108878E+09 | 0.265228E+09 | 54852107.31 |
| Annual Sum or Average | 0.163917E+10 | 87245866.33 | 0.155193E+10 | 0.436227E+10 | 0.247356E+09 |
| Minimum of Months | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.265228E+09 | 3498860.21 |
| Maximum of Months | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.562131E+09 | 54852107.31 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N N2A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.112074E+09 | 0.00 | 0.112074E+09 | 0.276716E+09 | 46218435.93 |
| February | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.282390E+09 | 28117436.96 |
| March | 0.122797E+09 | 21683.77 | 0.122775E+09 | 0.343902E+09 | 16245169.16 |
| April | 0.130886E+09 | 2466740.50 | 0.128420E+09 | 0.387497E+09 | 3496072.37 |
| May | 0.171666E+09 | 18735234.68 | 0.152931E+09 | 0.500020E+09 | 6950861.32 |
| June | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.562117E+09 | 7402888.70 |
| July | 0.179198E+09 | 18240175.10 | 0.160958E+09 | 0.454196E+09 | 17327033.50 |
| August | 0.149152E+09 | 7326383.82 | 0.141826E+09 | 0.382996E+09 | 12176071.96 |
| September | 0.122176E+09 | 168559.27 | 0.122007E+09 | 0.329565E+09 | 11470828.20 |
| October | 0.121434E+09 | 0.00 | 0.121434E+09 | 0.301071E+09 | 17079668.16 |
| November | 0.111197E+09 | 0.00 | 0.111197E+09 | 0.276360E+09 | 25958754.14 |
| December | 0.108878E+09 | 0.00 | 0.108878E+09 | 0.265191E+09 | 54844571.11 |
| Annual Sum or Average | 0.163917E+10 | 87245866.33 | 0.155193E+10 | 0.436202E+10 | 0.247288E+09 |
| Minimum of Months | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.265191E+09 | 3496072.37 |
| Maximum of Months | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.562117E+09 | 54844571.11 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S S1A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.294108E+09 | 0.121162E+09 | 0.172946E+09 | 0.662146E+09 | 44817087.98 |
| February | 0.229638E+09 | 76259171.80 | 0.153379E+09 | 0.558262E+09 | 26945858.53 |
| March | 0.172569E+09 | 23772949.97 | 0.148796E+09 | 0.472753E+09 | 14698879.86 |
| April | 0.125658E+09 | 1329232.19 | 0.124329E+09 | 0.381692E+09 | 3437905.85 |
| May | 0.128288E+09 | 0.00 | 0.128288E+09 | 0.399368E+09 | 6480646.93 |
| June | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.381282E+09 | 6932388.78 |
| July | 0.131680E+09 | 0.00 | 0.131680E+09 | 0.344059E+09 | 16337109.42 |
| August | 0.128072E+09 | 78684.75 | 0.127993E+09 | 0.334816E+09 | 11047650.75 |
| September | 0.136697E+09 | 3766062.87 | 0.132931E+09 | 0.364776E+09 | 11540236.16 |
| October | 0.184496E+09 | 28412967.82 | 0.156083E+09 | 0.442545E+09 | 18146317.10 |
| November | 0.236031E+09 | 73614914.47 | 0.162416E+09 | 0.543258E+09 | 27344579.00 |
| December | 0.295679E+09 | 0.125273E+09 | 0.170406E+09 | 0.653143E+09 | 54986999.78 |
| Annual Sum or Average | 0.218662E+10 | 0.453669E+09 | 0.173295E+10 | 0.553810E+10 | 0.242716E+09 |
| Minimum of Months | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.334816E+09 | 3437905.85 |
| Maximum of Months | 0.295679E+09 | 0.125273E+09 | 0.172946E+09 | 0.662146E+09 | 54986999.78 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S S2A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.294108E+09 | 0.121162E+09 | 0.172946E+09 | 0.662113E+09 | 44807779.22 |
| February | 0.229638E+09 | 76259171.80 | 0.153379E+09 | 0.558234E+09 | 26938066.47 |
| March | 0.172569E+09 | 23772949.97 | 0.148796E+09 | 0.472748E+09 | 14685092.22 |
| April | 0.125658E+09 | 1329232.19 | 0.124329E+09 | 0.381686E+09 | 3435373.47 |
| May | 0.128288E+09 | 0.00 | 0.128288E+09 | 0.399355E+09 | 6476771.52 |
| June | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.381267E+09 | 6930250.65 |
| July | 0.131680E+09 | 0.00 | 0.131680E+09 | 0.344044E+09 | 16329719.48 |
| August | 0.128072E+09 | 78684.75 | 0.127993E+09 | 0.334795E+09 | 11042958.92 |
| September | 0.136697E+09 | 3766062.87 | 0.132931E+09 | 0.364759E+09 | 11537379.93 |
| October | 0.184496E+09 | 28412967.82 | 0.156083E+09 | 0.442534E+09 | 18139740.61 |
| November | 0.236031E+09 | 73614914.47 | 0.162416E+09 | 0.543242E+09 | 27339785.48 |
| December | 0.295679E+09 | 0.125273E+09 | 0.170406E+09 | 0.653113E+09 | 54977762.89 |
| Annual Sum or Average | 0.218662E+10 | 0.453669E+09 | 0.173295E+10 | 0.553789E+10 | 0.242641E+09 |
| Minimum of Months | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.334795E+09 | 3435373.47 |
| Maximum of Months | 0.295679E+09 | 0.125273E+09 | 0.172946E+09 | 0.662113E+09 | 54977762.89 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S SWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.294108E+09 | 0.121162E+09 | 0.172946E+09 | 0.646471E+09 | 44773002.55 |
| February | 0.229638E+09 | 76259171.80 | 0.153379E+09 | 0.542339E+09 | 26845943.40 |
| March | 0.172569E+09 | 23772949.97 | 0.148796E+09 | 0.453173E+09 | 15337160.26 |
| April | 0.125658E+09 | 1329232.19 | 0.124329E+09 | 0.360872E+09 | 3625820.44 |
| May | 0.128288E+09 | 0.00 | 0.128288E+09 | 0.379668E+09 | 7217036.50 |
| June | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.361544E+09 | 7784528.93 |
| July | 0.131680E+09 | 0.00 | 0.131680E+09 | 0.327916E+09 | 17851529.27 |
| August | 0.128072E+09 | 78684.75 | 0.127993E+09 | 0.318114E+09 | 11930166.91 |
| September | 0.136697E+09 | 3766062.87 | 0.132931E+09 | 0.348234E+09 | 12798527.69 |
| October | 0.184496E+09 | 28412967.82 | 0.156083E+09 | 0.427282E+09 | 19483898.11 |
| November | 0.236031E+09 | 73614914.47 | 0.162416E+09 | 0.528373E+09 | 27813420.61 |
| December | 0.295679E+09 | 0.125273E+09 | 0.170406E+09 | 0.638759E+09 | 54795363.46 |
| Annual Sum or Average | 0.218662E+10 | 0.453669E+09 | 0.173295E+10 | 0.533275E+10 | 0.250256E+09 |
| Minimum of Months | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.318114E+09 | 3625820.44 |
| Maximum of Months | 0.295679E+09 | 0.125273E+09 | 0.172946E+09 | 0.646471E+09 | 54795363.46 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 W SWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.144440E+09 | 51007891.94 | 93431797.15 | 0.312996E+09 | 31738365.39 |
| February | 0.142919E+09 | 50583646.60 | 92335829.04 | 0.319520E+09 | 19201777.66 |
| March | 0.177465E+09 | 70161407.30 | 0.107304E+09 | 0.408631E+09 | 11651595.39 |
| April | 0.172262E+09 | 65844908.15 | 0.106417E+09 | 0.411661E+09 | 2427246.41 |
| May | 0.151639E+09 | 44914133.92 | 0.106725E+09 | 0.381609E+09 | 4646579.44 |
| June | 0.158946E+09 | 54734314.60 | 0.104212E+09 | 0.391062E+09 | 5039086.92 |
| July | 0.140175E+09 | 33089957.42 | 0.107085E+09 | 0.323035E+09 | 11566703.37 |
| August | 0.152481E+09 | 45211569.73 | 0.107270E+09 | 0.342281E+09 | 7711654.53 |
| September | 0.137950E+09 | 38170678.12 | 99779476.24 | 0.319682E+09 | 8219191.96 |
| October | 0.134002E+09 | 34526987.88 | 99475174.21 | 0.293702E+09 | 12535076.86 |
| November | 0.126282E+09 | 34315245.16 | 91966963.64 | 0.276092E+09 | 18281831.29 |
| December | 0.133808E+09 | 43820569.77 | 89987146.69 | 0.288601E+09 | 37466864.47 |
| Annual Sum or Average | 0.177237E+10 | 0.566381E+09 | 0.120599E+10 | 0.406887E+10 | 0.170486E+09 |
| Minimum of Months | 0.126282E+09 | 33089957.42 | 89987146.69 | 0.276092E+09 | 2427246.41 |
| Maximum of Months | 0.177465E+09 | 70161407.30 | 0.107304E+09 | 0.411661E+09 | 37466864.47 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 W NWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.144440E+09 | 51007891.94 | 93431797.15 | 0.318479E+09 | 30479534.60 |
| February | 0.142919E+09 | 50583646.60 | 92335829.04 | 0.323806E+09 | 18459773.06 |
| March | 0.177465E+09 | 70161407.30 | 0.107304E+09 | 0.410728E+09 | 11327362.73 |
| April | 0.172262E+09 | 65844908.15 | 0.106417E+09 | 0.411286E+09 | 2426903.56 |
| May | 0.151639E+09 | 44914133.92 | 0.106725E+09 | 0.379595E+09 | 4774807.17 |
| June | 0.158946E+09 | 54734314.60 | 0.104212E+09 | 0.387479E+09 | 5238409.12 |
| July | 0.140175E+09 | 33089957.42 | 0.107085E+09 | 0.321047E+09 | 11865717.40 |
| August | 0.152481E+09 | 45211569.73 | 0.107270E+09 | 0.341143E+09 | 7817176.54 |
| September | 0.137950E+09 | 38170678.12 | 99779476.24 | 0.320253E+09 | 8178185.22 |
| October | 0.134002E+09 | 34526987.88 | 99475174.21 | 0.295892E+09 | 12199754.57 |
| November | 0.126282E+09 | 34315245.16 | 91966963.64 | 0.280248E+09 | 17636420.70 |
| December | 0.133808E+09 | 43820569.77 | 89987146.69 | 0.294293E+09 | 36070904.23 |
| Annual Sum or Average | 0.177237E+10 | 0.566381E+09 | 0.120599E+10 | 0.408425E+10 | 0.166475E+09 |
| Minimum of Months | 0.126282E+09 | 33089957.42 | 89987146.69 | 0.280248E+09 | 2426903.56 |
| Maximum of Months | 0.177465E+09 | 70161407.30 | 0.107304E+09 | 0.411286E+09 | 36070904.23 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N NWA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.112074E+09 | 0.00 | 0.112074E+09 | 0.263043E+09 | 46625675.63 |
| February | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.268160E+09 | 28683963.05 |
| March | 0.122797E+09 | 21683.77 | 0.122775E+09 | 0.325497E+09 | 17445622.91 |
| April | 0.130886E+09 | 2466740.50 | 0.128420E+09 | 0.366770E+09 | 3727852.96 |
| May | 0.171666E+09 | 18735234.68 | 0.152931E+09 | 0.479945E+09 | 7647527.75 |
| June | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.541973E+09 | 8157356.21 |
| July | 0.179198E+09 | 18240175.10 | 0.160958E+09 | 0.437385E+09 | 18710025.45 |
| August | 0.149152E+09 | 7326383.82 | 0.141826E+09 | 0.366471E+09 | 13117596.87 |
| September | 0.122176E+09 | 168559.27 | 0.122007E+09 | 0.313464E+09 | 12783214.12 |
| October | 0.121434E+09 | 0.00 | 0.121434E+09 | 0.286834E+09 | 18620158.51 |
| November | 0.111197E+09 | 0.00 | 0.111197E+09 | 0.262956E+09 | 26829543.28 |
| December | 0.108878E+09 | 0.00 | 0.108878E+09 | 0.252716E+09 | 54947243.41 |
| Annual Sum or Average | 0.163917E+10 | 87245866.33 | 0.155193E+10 | 0.416521E+10 | 0.257296E+09 |
| Minimum of Months | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.252716E+09 | 3727852.96 |
| Maximum of Months | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.541973E+09 | 54947243.41 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S SEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.294108E+09 | 0.121162E+09 | 0.172946E+09 | 0.645030E+09 | 44056219.94 |
| February | 0.229638E+09 | 76259171.80 | 0.153379E+09 | 0.541239E+09 | 26389397.80 |
| March | 0.172569E+09 | 23772949.97 | 0.148796E+09 | 0.453059E+09 | 14832458.29 |
| April | 0.125658E+09 | 1329232.19 | 0.124329E+09 | 0.360840E+09 | 3550852.02 |
| May | 0.128288E+09 | 0.00 | 0.128288E+09 | 0.379253E+09 | 7080706.23 |
| June | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.360943E+09 | 7611427.55 |
| July | 0.131680E+09 | 0.00 | 0.131680E+09 | 0.327300E+09 | 17482367.91 |
| August | 0.128072E+09 | 78684.75 | 0.127993E+09 | 0.317320E+09 | 11645460.06 |
| September | 0.136697E+09 | 3766062.87 | 0.132931E+09 | 0.347596E+09 | 12555017.54 |
| October | 0.184496E+09 | 28412967.82 | 0.156083E+09 | 0.426778E+09 | 19125861.93 |
| November | 0.236031E+09 | 73614914.47 | 0.162416E+09 | 0.527753E+09 | 27483360.14 |
| December | 0.295679E+09 | 0.125273E+09 | 0.170406E+09 | 0.637438E+09 | 54115294.63 |
| Annual Sum or Average | 0.218662E+10 | 0.453669E+09 | 0.173295E+10 | 0.532455E+10 | 0.245928E+09 |
| Minimum of Months | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.317320E+09 | 3550852.02 |
| Maximum of Months | 0.295679E+09 | 0.125273E+09 | 0.172946E+09 | 0.645030E+09 | 54115294.63 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 E SEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.142511E+09 | 48248987.90 | 94261877.90 | 0.305110E+09 | 28714820.12 |
| February | 0.145223E+09 | 52997774.44 | 92224754.87 | 0.321972E+09 | 16942088.87 |
| March | 0.175875E+09 | 68744128.74 | 0.107131E+09 | 0.404793E+09 | 9418026.43 |
| April | 0.171933E+09 | 65708941.82 | 0.106224E+09 | 0.415646E+09 | 2263386.98 |
| May | 0.152642E+09 | 46161163.88 | 0.106480E+09 | 0.386742E+09 | 4783641.69 |
| June | 0.157442E+09 | 51884356.97 | 0.105557E+09 | 0.390029E+09 | 5027099.68 |
| July | 0.139012E+09 | 31214610.43 | 0.107797E+09 | 0.321556E+09 | 11681839.94 |
| August | 0.152812E+09 | 44867602.37 | 0.107945E+09 | 0.345621E+09 | 8176798.07 |
| September | 0.139033E+09 | 37944930.92 | 0.101088E+09 | 0.324614E+09 | 8166623.51 |
| October | 0.134781E+09 | 34603181.21 | 0.100178E+09 | 0.296706E+09 | 12309311.30 |
| November | 0.126340E+09 | 35025750.75 | 91314286.72 | 0.276284E+09 | 17758299.60 |
| December | 0.133345E+09 | 42828667.37 | 90516747.55 | 0.283539E+09 | 35087197.66 |
| Annual Sum or Average | 0.177095E+10 | 0.560230E+09 | 0.121072E+10 | 0.407261E+10 | 0.160329E+09 |
| Minimum of Months | 0.126340E+09 | 31214610.43 | 90516747.55 | 0.276284E+09 | 2263386.98 |
| Maximum of Months | 0.175875E+09 | 68744128.74 | 0.107945E+09 | 0.415646E+09 | 35087197.66 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 E NEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.142511E+09 | 48248987.90 | 94261877.90 | 0.310649E+09 | 27618004.70 |
| February | 0.145223E+09 | 52997774.44 | 92224754.87 | 0.326367E+09 | 16318123.79 |
| March | 0.175875E+09 | 68744128.74 | 0.107131E+09 | 0.407023E+09 | 9127086.00 |
| April | 0.171933E+09 | 65708941.82 | 0.106224E+09 | 0.415256E+09 | 2262125.48 |
| May | 0.152642E+09 | 46161163.88 | 0.106480E+09 | 0.384736E+09 | 4913867.02 |
| June | 0.157442E+09 | 51884356.97 | 0.105557E+09 | 0.386547E+09 | 5232995.55 |
| July | 0.139012E+09 | 31214610.43 | 0.107797E+09 | 0.319624E+09 | 11990240.24 |
| August | 0.152812E+09 | 44867602.37 | 0.107945E+09 | 0.344530E+09 | 8283720.77 |
| September | 0.139033E+09 | 37944930.92 | 0.101088E+09 | 0.325180E+09 | 8128526.23 |
| October | 0.134781E+09 | 34603181.21 | 0.100178E+09 | 0.298917E+09 | 11982711.47 |
| November | 0.126340E+09 | 35025750.75 | 91314286.72 | 0.280456E+09 | 17124962.26 |
| December | 0.133345E+09 | 42828667.37 | 90516747.55 | 0.289308E+09 | 33844519.26 |
| Annual Sum or Average | 0.177095E+10 | 0.560230E+09 | 0.121072E+10 | 0.408859E+10 | 0.156827E+09 |
| Minimum of Months | 0.126340E+09 | 31214610.43 | 90516747.55 | 0.280456E+09 | 2262125.48 |
| Maximum of Months | 0.175875E+09 | 68744128.74 | 0.107945E+09 | 0.415256E+09 | 33844519.26 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N NEA
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.112074E+09 | 0.00 | 0.112074E+09 | 0.261368E+09 | 46017296.75 |
| February | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.266895E+09 | 28265018.10 |
| March | 0.122797E+09 | 21683.77 | 0.122775E+09 | 0.325217E+09 | 16867969.43 |
| April | 0.130886E+09 | 2466740.50 | 0.128420E+09 | 0.366665E+09 | 3640618.16 |
| May | 0.171666E+09 | 18735234.68 | 0.152931E+09 | 0.479513E+09 | 7505992.38 |
| June | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.541361E+09 | 7983106.64 |
| July | 0.179198E+09 | 18240175.10 | 0.160958E+09 | 0.436706E+09 | 18351399.86 |
| August | 0.149152E+09 | 7326383.82 | 0.141826E+09 | 0.365688E+09 | 12809867.20 |
| September | 0.122176E+09 | 168559.27 | 0.122007E+09 | 0.312798E+09 | 12536437.36 |
| October | 0.121434E+09 | 0.00 | 0.121434E+09 | 0.286310E+09 | 18268363.79 |
| November | 0.111197E+09 | 0.00 | 0.111197E+09 | 0.262273E+09 | 26516539.55 |
| December | 0.108878E+09 | 0.00 | 0.108878E+09 | 0.251307E+09 | 54369762.40 |
| Annual Sum or Average | 0.163917E+10 | 87245866.33 | 0.155193E+10 | 0.415610E+10 | 0.253132E+09 |
| Minimum of Months | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.251307E+09 | 3640618.16 |
| Maximum of Months | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.541361E+09 | 54369762.40 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N N1A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.112074E+09 | 0.00 | 0.112074E+09 | 0.268990E+09 | 45724283.13 |
| February | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.274707E+09 | 27711311.10 |
| March | 0.122797E+09 | 21683.77 | 0.122775E+09 | 0.334379E+09 | 16348970.30 |
| April | 0.130886E+09 | 2466740.50 | 0.128420E+09 | 0.376677E+09 | 3508803.82 |
| May | 0.171666E+09 | 18735234.68 | 0.152931E+09 | 0.488617E+09 | 7253107.86 |
| June | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.550438E+09 | 7729009.49 |
| July | 0.179198E+09 | 18240175.10 | 0.160958E+09 | 0.444019E+09 | 17825719.91 |
| August | 0.149152E+09 | 7326383.82 | 0.141826E+09 | 0.373562E+09 | 12482273.08 |
| September | 0.122176E+09 | 168559.27 | 0.122007E+09 | 0.320480E+09 | 12125574.72 |
| October | 0.121434E+09 | 0.00 | 0.121434E+09 | 0.292967E+09 | 17858145.62 |
| November | 0.111197E+09 | 0.00 | 0.111197E+09 | 0.268785E+09 | 26199989.01 |
| December | 0.108878E+09 | 0.00 | 0.108878E+09 | 0.258081E+09 | 54298640.74 |
| Annual Sum or Average | 0.163917E+10 | 87245866.33 | 0.155193E+10 | 0.425170E+10 | 0.249066E+09 |
| Minimum of Months | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.258081E+09 | 3508803.82 |
| Maximum of Months | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.550438E+09 | 54298640.74 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N N2A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.112074E+09 | 0.00 | 0.112074E+09 | 0.268880E+09 | 45693019.57 |
| February | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.274631E+09 | 27686411.17 |
| March | 0.122797E+09 | 21683.77 | 0.122775E+09 | 0.334360E+09 | 16317539.01 |
| April | 0.130886E+09 | 2466740.50 | 0.128420E+09 | 0.376669E+09 | 3503218.36 |
| May | 0.171666E+09 | 18735234.68 | 0.152931E+09 | 0.488598E+09 | 7245008.97 |
| June | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.550412E+09 | 7719591.19 |
| July | 0.179198E+09 | 18240175.10 | 0.160958E+09 | 0.443987E+09 | 17805975.55 |
| August | 0.149152E+09 | 7326383.82 | 0.141826E+09 | 0.373524E+09 | 12466553.85 |
| September | 0.122176E+09 | 168559.27 | 0.122007E+09 | 0.320449E+09 | 12112698.95 |
| October | 0.121434E+09 | 0.00 | 0.121434E+09 | 0.292940E+09 | 17839859.96 |
| November | 0.111197E+09 | 0.00 | 0.111197E+09 | 0.268749E+09 | 26181161.50 |
| December | 0.108878E+09 | 0.00 | 0.108878E+09 | 0.257997E+09 | 54266914.99 |
| Annual Sum or Average | 0.163917E+10 | 87245866.33 | 0.155193E+10 | 0.425120E+10 | 0.248838E+09 |
| Minimum of Months | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.257997E+09 | 3503218.36 |
| Maximum of Months | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.550412E+09 | 54266914.99 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S S1A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.294108E+09 | 0.121162E+09 | 0.172946E+09 | 0.651801E+09 | 43906460.09 |
| February | 0.229638E+09 | 76259171.80 | 0.153379E+09 | 0.548597E+09 | 26033204.16 |
| March | 0.172569E+09 | 23772949.97 | 0.148796E+09 | 0.462212E+09 | 14401855.27 |
| April | 0.125658E+09 | 1329232.19 | 0.124329E+09 | 0.371185E+09 | 3440806.47 |
| May | 0.128288E+09 | 0.00 | 0.128288E+09 | 0.388861E+09 | 6835110.15 |
| June | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.370856E+09 | 7347390.25 |
| July | 0.131680E+09 | 0.00 | 0.131680E+09 | 0.334880E+09 | 16933908.95 |
| August | 0.128072E+09 | 78684.75 | 0.127993E+09 | 0.325634E+09 | 11339652.98 |
| September | 0.136697E+09 | 3766062.87 | 0.132931E+09 | 0.355304E+09 | 12156388.54 |
| October | 0.184496E+09 | 28412967.82 | 0.156083E+09 | 0.433242E+09 | 18750272.49 |
| November | 0.236031E+09 | 73614914.47 | 0.162416E+09 | 0.533792E+09 | 27250521.35 |
| December | 0.295679E+09 | 0.125273E+09 | 0.170406E+09 | 0.643429E+09 | 54137395.32 |
| Annual Sum or Average | 0.218662E+10 | 0.453669E+09 | 0.173295E+10 | 0.541979E+10 | 0.242533E+09 |
| Minimum of Months | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.325634E+09 | 3440806.47 |
| Maximum of Months | 0.295679E+09 | 0.125273E+09 | 0.172946E+09 | 0.651801E+09 | 54137395.32 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S S2A
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.294108E+09 | 0.121162E+09 | 0.172946E+09 | 0.651725E+09 | 43873417.89 |
| February | 0.229638E+09 | 76259171.80 | 0.153379E+09 | 0.548539E+09 | 26009324.82 |
| March | 0.172569E+09 | 23772949.97 | 0.148796E+09 | 0.462199E+09 | 14372474.83 |
| April | 0.125658E+09 | 1329232.19 | 0.124329E+09 | 0.371180E+09 | 3435976.03 |
| May | 0.128288E+09 | 0.00 | 0.128288E+09 | 0.388841E+09 | 6827403.39 |
| June | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.370829E+09 | 7337985.62 |
| July | 0.131680E+09 | 0.00 | 0.131680E+09 | 0.334849E+09 | 16913379.15 |
| August | 0.128072E+09 | 78684.75 | 0.127993E+09 | 0.325595E+09 | 11324221.77 |
| September | 0.136697E+09 | 3766062.87 | 0.132931E+09 | 0.355274E+09 | 12142842.88 |
| October | 0.184496E+09 | 28412967.82 | 0.156083E+09 | 0.433217E+09 | 18731659.08 |
| November | 0.236031E+09 | 73614914.47 | 0.162416E+09 | 0.533760E+09 | 27232676.05 |
| December | 0.295679E+09 | 0.125273E+09 | 0.170406E+09 | 0.643363E+09 | 54105625.40 |
| Annual Sum or Average | 0.218662E+10 | 0.453669E+09 | 0.173295E+10 | 0.541937E+10 | 0.242307E+09 |
| Minimum of Months | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.325595E+09 | 3435976.03 |
| Maximum of Months | 0.295679E+09 | 0.125273E+09 | 0.172946E+09 | 0.651725E+09 | 54105625.40 |
Report: WindowEnergyReportMonthly
For: TWINDOW14
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 34196062.32 | 11577541.04 | 22618521.28 | 69110939.29 | 11059028.01 |
| February | 34846737.02 | 12717031.70 | 22129705.32 | 73046369.90 | 7547492.01 |
| March | 42201909.13 | 16495433.51 | 25706475.63 | 90866946.19 | 5686861.32 |
| April | 41256065.79 | 15767128.05 | 25488937.74 | 91306983.77 | 2142237.51 |
| May | 36626963.32 | 11076559.17 | 25550404.15 | 84293392.34 | 3313454.32 |
| June | 37778802.05 | 12449862.65 | 25328939.41 | 85493859.97 | 3490826.67 |
| July | 33356445.68 | 7490072.83 | 25866372.85 | 70898363.25 | 6401581.80 |
| August | 36667957.47 | 10766163.82 | 25901793.65 | 76609321.16 | 5496536.63 |
| September | 33361452.95 | 9105040.63 | 24256412.32 | 71781427.61 | 5200915.32 |
| October | 32341302.13 | 8303174.18 | 24038127.95 | 65721269.74 | 6967667.17 |
| November | 30315806.25 | 8404571.46 | 21911234.78 | 61656499.46 | 8053896.90 |
| December | 31996775.08 | 10276913.06 | 21719862.01 | 64309386.06 | 12807923.85 |
| Annual Sum or Average | 0.424946E+09 | 0.134429E+09 | 0.290517E+09 | 0.905095E+09 | 78168421.50 |
| Minimum of Months | 30315806.25 | 7490072.83 | 21719862.01 | 61656499.46 | 2142237.51 |
| Maximum of Months | 42201909.13 | 16495433.51 | 25901793.65 | 91306983.77 | 12807923.85 |
Report: WindowEnergyReportMonthly
For: ENTRANCE DOOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.101844E+09 | 34480798.44 | 67363585.30 | 0.197204E+09 | 44622256.05 |
| February | 0.103782E+09 | 37874485.21 | 65907769.73 | 0.208134E+09 | 33733048.97 |
| March | 0.125688E+09 | 49127506.10 | 76560281.81 | 0.259023E+09 | 29284461.18 |
| April | 0.122871E+09 | 46958431.20 | 75912399.85 | 0.258168E+09 | 16205879.85 |
| May | 0.109084E+09 | 32988749.75 | 76095462.12 | 0.235098E+09 | 18502434.92 |
| June | 0.112515E+09 | 37078789.27 | 75435885.00 | 0.240781E+09 | 19663819.94 |
| July | 99343796.42 | 22307300.89 | 77036495.53 | 0.200206E+09 | 28778007.83 |
| August | 0.109206E+09 | 32064315.15 | 77141987.50 | 0.216662E+09 | 26684016.29 |
| September | 99358709.32 | 27117076.90 | 72241632.42 | 0.202970E+09 | 24962578.17 |
| October | 96320446.31 | 24728919.06 | 71591527.25 | 0.186126E+09 | 31175580.51 |
| November | 90288015.50 | 25030905.40 | 65257110.09 | 0.175126E+09 | 34316863.51 |
| December | 95294359.01 | 30607204.65 | 64687154.36 | 0.183371E+09 | 49421992.24 |
| Annual Sum or Average | 0.126560E+10 | 0.400364E+09 | 0.865231E+09 | 0.256287E+10 | 0.357351E+09 |
| Minimum of Months | 90288015.50 | 22307300.89 | 64687154.36 | 0.175126E+09 | 16205879.85 |
| Maximum of Months | 0.125688E+09 | 49127506.10 | 77141987.50 | 0.259023E+09 | 49421992.24 |
Report: WindowEnergyReportMonthly
For: MWINDOW14
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 34196062.32 | 11577541.04 | 22618521.28 | 70316659.12 | 11018759.84 |
| February | 34846737.02 | 12717031.70 | 22129705.32 | 74360934.51 | 7568321.03 |
| March | 42201909.13 | 16495433.51 | 25706475.63 | 92668973.41 | 5526409.36 |
| April | 41256065.79 | 15767128.05 | 25488937.74 | 93602647.33 | 2094699.26 |
| May | 36626963.32 | 11076559.17 | 25550404.15 | 86597515.22 | 3104114.19 |
| June | 37778802.05 | 12449862.65 | 25328939.41 | 87703701.55 | 3240106.27 |
| July | 33356445.68 | 7490072.83 | 25866372.85 | 72542714.38 | 6099904.73 |
| August | 36667957.47 | 10766163.82 | 25901793.65 | 78152487.12 | 5174716.08 |
| September | 33361452.95 | 9105040.63 | 24256412.32 | 73437779.79 | 4873401.68 |
| October | 32341302.13 | 8303174.18 | 24038127.95 | 67136821.65 | 6638614.07 |
| November | 30315806.25 | 8404571.46 | 21911234.78 | 62937541.77 | 7860578.49 |
| December | 31996775.08 | 10276913.06 | 21719862.01 | 65360130.54 | 12773575.71 |
| Annual Sum or Average | 0.424946E+09 | 0.134429E+09 | 0.290517E+09 | 0.924818E+09 | 75973200.71 |
| Minimum of Months | 30315806.25 | 7490072.83 | 21719862.01 | 62937541.77 | 2094699.26 |
| Maximum of Months | 42201909.13 | 16495433.51 | 25901793.65 | 93602647.33 | 12773575.71 |
Report: WindowZoneSummaryMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 362.61 | 32.19 | 163.73 | 64.28 | 99.45 | 0.00 | 0.00 |
| February | 360.81 | 23.02 | 154.00 | 52.43 | 101.57 | 0.00 | 0.00 |
| March | 325.87 | 12.91 | 130.69 | 35.07 | 95.62 | 0.00 | 0.00 |
| April | 300.35 | 3.18 | 114.94 | 25.92 | 89.02 | 0.00 | 0.00 |
| May | 286.21 | 5.71 | 104.51 | 16.77 | 87.74 | 0.00 | 0.00 |
| June | 292.02 | 6.15 | 109.05 | 21.12 | 87.93 | 0.00 | 0.00 |
| July | 245.88 | 13.60 | 101.50 | 12.35 | 89.14 | 0.00 | 0.00 |
| August | 248.52 | 9.67 | 104.75 | 16.91 | 87.84 | 0.00 | 0.00 |
| September | 260.46 | 10.22 | 105.96 | 16.18 | 89.78 | 0.00 | 0.00 |
| October | 272.92 | 14.52 | 118.91 | 23.50 | 95.41 | 0.00 | 0.00 |
| November | 314.45 | 20.94 | 139.78 | 41.64 | 98.14 | 0.00 | 0.00 |
| December | 350.15 | 38.13 | 160.35 | 63.13 | 97.22 | 0.00 | 0.00 |
| Annual Sum or Average | 301.31 | 15.86 | 125.54 | 32.35 | 93.19 | 0.00 | 0.00 |
| Minimum of Months | 245.88 | 3.18 | 101.50 | 12.35 | 87.74 | 0.00 | 0.00 |
| Maximum of Months | 362.61 | 38.13 | 163.73 | 64.28 | 101.57 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 220.25 | 32.43 | 95.77 | 19.04 | 76.73 | 0.00 | 0.00 |
| February | 248.17 | 23.20 | 103.71 | 20.91 | 82.80 | 0.00 | 0.00 |
| March | 278.55 | 13.27 | 112.11 | 26.20 | 85.90 | 0.00 | 0.00 |
| April | 302.95 | 3.31 | 116.96 | 26.35 | 90.60 | 0.00 | 0.00 |
| May | 323.67 | 6.03 | 120.71 | 23.76 | 96.94 | 0.00 | 0.00 |
| June | 361.39 | 6.51 | 139.15 | 36.66 | 102.49 | 0.00 | 0.00 |
| July | 286.70 | 14.17 | 119.24 | 19.16 | 100.08 | 0.00 | 0.00 |
| August | 266.50 | 10.16 | 112.62 | 19.62 | 93.00 | 0.00 | 0.00 |
| September | 247.01 | 10.18 | 100.36 | 14.79 | 85.57 | 0.00 | 0.00 |
| October | 220.47 | 13.92 | 95.37 | 12.89 | 82.48 | 0.00 | 0.00 |
| November | 212.43 | 20.09 | 91.62 | 13.24 | 78.38 | 0.00 | 0.00 |
| December | 206.87 | 37.82 | 90.61 | 16.36 | 74.25 | 0.00 | 0.00 |
| Annual Sum or Average | 264.54 | 15.93 | 108.18 | 20.73 | 87.45 | 0.00 | 0.00 |
| Minimum of Months | 206.87 | 3.31 | 90.61 | 12.89 | 74.25 | 0.00 | 0.00 |
| Maximum of Months | 361.39 | 37.82 | 139.15 | 36.66 | 102.49 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 334.16 | 71.31 | 163.01 | 63.25 | 99.76 | 0.00 | 0.00 |
| February | 335.17 | 60.82 | 154.95 | 53.43 | 101.52 | 0.00 | 0.00 |
| March | 296.34 | 48.66 | 130.09 | 34.54 | 95.55 | 0.00 | 0.00 |
| April | 260.19 | 32.25 | 114.81 | 25.86 | 88.95 | 0.00 | 0.00 |
| May | 245.27 | 33.34 | 104.89 | 17.23 | 87.65 | 0.00 | 0.00 |
| June | 252.85 | 35.03 | 108.47 | 20.02 | 88.45 | 0.00 | 0.00 |
| July | 212.37 | 48.13 | 101.06 | 11.65 | 89.41 | 0.00 | 0.00 |
| August | 221.50 | 43.72 | 104.87 | 16.78 | 88.09 | 0.00 | 0.00 |
| September | 230.12 | 44.30 | 106.38 | 16.09 | 90.29 | 0.00 | 0.00 |
| October | 245.58 | 52.32 | 119.20 | 23.53 | 95.68 | 0.00 | 0.00 |
| November | 287.75 | 57.91 | 139.80 | 41.91 | 97.89 | 0.00 | 0.00 |
| December | 325.82 | 75.66 | 160.18 | 62.76 | 97.42 | 0.00 | 0.00 |
| Annual Sum or Average | 270.20 | 50.29 | 125.49 | 32.15 | 93.34 | 0.00 | 0.00 |
| Minimum of Months | 212.37 | 32.25 | 101.06 | 11.65 | 87.65 | 0.00 | 0.00 |
| Maximum of Months | 335.17 | 75.66 | 163.01 | 63.25 | 101.52 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 215.75 | 29.97 | 95.05 | 18.01 | 77.04 | 0.00 | 0.00 |
| February | 248.01 | 21.36 | 104.66 | 21.91 | 82.76 | 0.00 | 0.00 |
| March | 276.82 | 12.12 | 111.51 | 25.67 | 85.84 | 0.00 | 0.00 |
| April | 304.29 | 3.17 | 116.83 | 26.30 | 90.53 | 0.00 | 0.00 |
| May | 325.42 | 6.03 | 121.08 | 24.23 | 96.85 | 0.00 | 0.00 |
| June | 360.96 | 6.54 | 138.57 | 35.56 | 103.01 | 0.00 | 0.00 |
| July | 285.88 | 14.14 | 118.81 | 18.46 | 100.34 | 0.00 | 0.00 |
| August | 267.48 | 10.26 | 112.74 | 19.49 | 93.25 | 0.00 | 0.00 |
| September | 248.57 | 10.09 | 100.77 | 14.70 | 86.07 | 0.00 | 0.00 |
| October | 221.36 | 13.66 | 95.66 | 12.92 | 82.74 | 0.00 | 0.00 |
| November | 212.03 | 19.48 | 91.64 | 13.51 | 78.13 | 0.00 | 0.00 |
| December | 203.65 | 35.72 | 90.44 | 15.99 | 74.45 | 0.00 | 0.00 |
| Annual Sum or Average | 264.13 | 15.22 | 108.13 | 20.53 | 87.60 | 0.00 | 0.00 |
| Minimum of Months | 203.65 | 3.17 | 90.44 | 12.92 | 74.45 | 0.00 | 0.00 |
| Maximum of Months | 360.96 | 35.72 | 138.57 | 35.56 | 103.01 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 101.80 | 18.74 | 41.84 | 0.00 | 41.84 | 0.00 | 0.00 |
| February | 114.97 | 13.11 | 44.64 | 0.00 | 44.64 | 0.00 | 0.00 |
| March | 126.27 | 7.17 | 45.85 | 0.01 | 45.84 | 0.00 | 0.00 |
| April | 146.53 | 1.73 | 50.50 | 0.95 | 49.54 | 0.00 | 0.00 |
| May | 183.89 | 3.29 | 64.09 | 6.99 | 57.10 | 0.00 | 0.00 |
| June | 214.03 | 3.56 | 77.83 | 15.54 | 62.29 | 0.00 | 0.00 |
| July | 167.70 | 7.83 | 66.90 | 6.81 | 60.09 | 0.00 | 0.00 |
| August | 140.60 | 5.65 | 55.69 | 2.74 | 52.95 | 0.00 | 0.00 |
| September | 124.81 | 5.51 | 47.14 | 0.07 | 47.07 | 0.00 | 0.00 |
| October | 110.69 | 7.66 | 45.34 | 0.00 | 45.34 | 0.00 | 0.00 |
| November | 104.98 | 11.40 | 42.90 | 0.00 | 42.90 | 0.00 | 0.00 |
| December | 97.51 | 22.02 | 40.65 | 0.00 | 40.65 | 0.00 | 0.00 |
| Annual Sum or Average | 136.20 | 8.98 | 51.98 | 2.77 | 49.21 | 0.00 | 0.00 |
| Minimum of Months | 97.51 | 1.73 | 40.65 | 0.00 | 40.65 | 0.00 | 0.00 |
| Maximum of Months | 214.03 | 22.02 | 77.83 | 15.54 | 62.29 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 101.78 | 18.74 | 41.84 | 0.00 | 41.84 | 0.00 | 0.00 |
| February | 114.96 | 13.11 | 44.64 | 0.00 | 44.64 | 0.00 | 0.00 |
| March | 126.27 | 7.17 | 45.85 | 0.01 | 45.84 | 0.00 | 0.00 |
| April | 146.53 | 1.73 | 50.50 | 0.95 | 49.54 | 0.00 | 0.00 |
| May | 183.89 | 3.29 | 64.09 | 6.99 | 57.10 | 0.00 | 0.00 |
| June | 214.02 | 3.56 | 77.83 | 15.54 | 62.29 | 0.00 | 0.00 |
| July | 167.69 | 7.83 | 66.90 | 6.81 | 60.09 | 0.00 | 0.00 |
| August | 140.59 | 5.65 | 55.69 | 2.74 | 52.95 | 0.00 | 0.00 |
| September | 124.80 | 5.51 | 47.14 | 0.07 | 47.07 | 0.00 | 0.00 |
| October | 110.69 | 7.66 | 45.34 | 0.00 | 45.34 | 0.00 | 0.00 |
| November | 104.97 | 11.40 | 42.90 | 0.00 | 42.90 | 0.00 | 0.00 |
| December | 97.49 | 22.02 | 40.65 | 0.00 | 40.65 | 0.00 | 0.00 |
| Annual Sum or Average | 136.19 | 8.98 | 51.98 | 2.77 | 49.21 | 0.00 | 0.00 |
| Minimum of Months | 97.49 | 1.73 | 40.65 | 0.00 | 40.65 | 0.00 | 0.00 |
| Maximum of Months | 214.02 | 22.02 | 77.83 | 15.54 | 62.29 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 246.07 | 18.45 | 109.81 | 45.24 | 64.57 | 0.00 | 0.00 |
| February | 229.21 | 12.84 | 94.92 | 31.52 | 63.40 | 0.00 | 0.00 |
| March | 174.31 | 6.76 | 64.43 | 8.88 | 55.55 | 0.00 | 0.00 |
| April | 143.87 | 1.68 | 48.48 | 0.51 | 47.97 | 0.00 | 0.00 |
| May | 145.85 | 3.07 | 47.90 | 0.00 | 47.90 | 0.00 | 0.00 |
| June | 143.61 | 3.32 | 47.72 | 0.00 | 47.72 | 0.00 | 0.00 |
| July | 126.27 | 7.43 | 49.16 | 0.00 | 49.16 | 0.00 | 0.00 |
| August | 122.32 | 5.25 | 47.82 | 0.03 | 47.79 | 0.00 | 0.00 |
| September | 138.39 | 5.55 | 52.74 | 1.45 | 51.29 | 0.00 | 0.00 |
| October | 163.72 | 8.13 | 68.88 | 10.61 | 58.27 | 0.00 | 0.00 |
| November | 208.25 | 12.04 | 91.06 | 28.40 | 62.66 | 0.00 | 0.00 |
| December | 242.77 | 22.25 | 110.39 | 46.77 | 63.62 | 0.00 | 0.00 |
| Annual Sum or Average | 173.43 | 8.90 | 69.34 | 14.39 | 54.95 | 0.00 | 0.00 |
| Minimum of Months | 122.32 | 1.68 | 47.72 | 0.00 | 47.72 | 0.00 | 0.00 |
| Maximum of Months | 246.07 | 22.25 | 110.39 | 46.77 | 64.57 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 245.13 | 19.21 | 109.81 | 45.24 | 64.57 | 0.00 | 0.00 |
| February | 228.27 | 13.54 | 94.92 | 31.52 | 63.40 | 0.00 | 0.00 |
| March | 173.29 | 7.29 | 64.43 | 8.88 | 55.55 | 0.00 | 0.00 |
| April | 142.41 | 1.88 | 48.48 | 0.51 | 47.97 | 0.00 | 0.00 |
| May | 144.46 | 3.38 | 47.90 | 0.00 | 47.90 | 0.00 | 0.00 |
| June | 142.28 | 3.64 | 47.72 | 0.00 | 47.72 | 0.00 | 0.00 |
| July | 125.25 | 8.04 | 49.16 | 0.00 | 49.16 | 0.00 | 0.00 |
| August | 121.22 | 5.73 | 47.82 | 0.03 | 47.79 | 0.00 | 0.00 |
| September | 137.31 | 6.07 | 52.74 | 1.45 | 51.29 | 0.00 | 0.00 |
| October | 162.78 | 8.83 | 68.88 | 10.61 | 58.27 | 0.00 | 0.00 |
| November | 207.34 | 12.72 | 91.06 | 28.40 | 62.66 | 0.00 | 0.00 |
| December | 241.96 | 22.96 | 110.39 | 46.77 | 63.62 | 0.00 | 0.00 |
| Annual Sum or Average | 172.35 | 9.44 | 69.34 | 14.39 | 54.95 | 0.00 | 0.00 |
| Minimum of Months | 121.22 | 1.88 | 47.72 | 0.00 | 47.72 | 0.00 | 0.00 |
| Maximum of Months | 245.13 | 22.96 | 110.39 | 46.77 | 64.57 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 364.86 | 28.99 | 163.73 | 64.28 | 99.45 | 0.00 | 0.00 |
| February | 363.56 | 19.72 | 154.00 | 52.43 | 101.57 | 0.00 | 0.00 |
| March | 329.47 | 10.51 | 130.69 | 35.07 | 95.62 | 0.00 | 0.00 |
| April | 305.97 | 2.43 | 114.94 | 25.92 | 89.02 | 0.00 | 0.00 |
| May | 291.88 | 4.40 | 104.51 | 16.77 | 87.74 | 0.00 | 0.00 |
| June | 298.21 | 4.85 | 109.05 | 21.12 | 87.93 | 0.00 | 0.00 |
| July | 249.83 | 10.93 | 101.50 | 12.35 | 89.14 | 0.00 | 0.00 |
| August | 253.31 | 7.41 | 104.75 | 16.91 | 87.84 | 0.00 | 0.00 |
| September | 264.75 | 7.97 | 105.96 | 16.18 | 89.78 | 0.00 | 0.00 |
| October | 275.73 | 11.90 | 118.91 | 23.50 | 95.41 | 0.00 | 0.00 |
| November | 317.12 | 18.11 | 139.78 | 41.64 | 98.14 | 0.00 | 0.00 |
| December | 352.41 | 34.86 | 160.35 | 63.13 | 97.22 | 0.00 | 0.00 |
| Annual Sum or Average | 305.21 | 13.51 | 125.54 | 32.35 | 93.19 | 0.00 | 0.00 |
| Minimum of Months | 249.83 | 2.43 | 101.50 | 12.35 | 87.74 | 0.00 | 0.00 |
| Maximum of Months | 364.86 | 34.86 | 163.73 | 64.28 | 101.57 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 222.83 | 29.54 | 95.77 | 19.04 | 76.73 | 0.00 | 0.00 |
| February | 251.09 | 20.21 | 103.71 | 20.91 | 82.80 | 0.00 | 0.00 |
| March | 282.01 | 11.00 | 112.11 | 26.20 | 85.90 | 0.00 | 0.00 |
| April | 308.23 | 2.48 | 116.96 | 26.35 | 90.60 | 0.00 | 0.00 |
| May | 329.03 | 4.64 | 120.71 | 23.76 | 96.94 | 0.00 | 0.00 |
| June | 367.12 | 5.09 | 139.15 | 36.66 | 102.49 | 0.00 | 0.00 |
| July | 290.46 | 11.39 | 119.24 | 19.16 | 100.08 | 0.00 | 0.00 |
| August | 271.08 | 7.86 | 112.62 | 19.62 | 93.00 | 0.00 | 0.00 |
| September | 251.34 | 7.92 | 100.36 | 14.79 | 85.57 | 0.00 | 0.00 |
| October | 223.49 | 11.37 | 95.37 | 12.89 | 82.48 | 0.00 | 0.00 |
| November | 215.35 | 17.40 | 91.62 | 13.24 | 78.38 | 0.00 | 0.00 |
| December | 209.51 | 34.80 | 90.61 | 16.36 | 74.25 | 0.00 | 0.00 |
| Annual Sum or Average | 268.42 | 13.65 | 108.18 | 20.73 | 87.45 | 0.00 | 0.00 |
| Minimum of Months | 209.51 | 2.48 | 90.61 | 12.89 | 74.25 | 0.00 | 0.00 |
| Maximum of Months | 367.12 | 34.80 | 139.15 | 36.66 | 102.49 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 362.17 | 28.22 | 163.01 | 63.25 | 99.76 | 0.00 | 0.00 |
| February | 364.63 | 18.98 | 154.95 | 53.43 | 101.52 | 0.00 | 0.00 |
| March | 328.12 | 9.55 | 130.09 | 34.54 | 95.55 | 0.00 | 0.00 |
| April | 307.55 | 2.35 | 114.81 | 25.86 | 88.95 | 0.00 | 0.00 |
| May | 293.65 | 4.39 | 104.89 | 17.23 | 87.65 | 0.00 | 0.00 |
| June | 297.54 | 4.75 | 108.47 | 20.02 | 88.45 | 0.00 | 0.00 |
| July | 248.94 | 10.82 | 101.06 | 11.65 | 89.41 | 0.00 | 0.00 |
| August | 254.18 | 7.45 | 104.87 | 16.78 | 88.09 | 0.00 | 0.00 |
| September | 266.36 | 7.87 | 106.38 | 16.09 | 90.29 | 0.00 | 0.00 |
| October | 276.77 | 11.77 | 119.20 | 23.53 | 95.68 | 0.00 | 0.00 |
| November | 317.17 | 17.94 | 139.80 | 41.91 | 97.89 | 0.00 | 0.00 |
| December | 350.79 | 34.34 | 160.18 | 62.76 | 97.42 | 0.00 | 0.00 |
| Annual Sum or Average | 305.26 | 13.21 | 125.49 | 32.15 | 93.34 | 0.00 | 0.00 |
| Minimum of Months | 248.94 | 2.35 | 101.06 | 11.65 | 87.65 | 0.00 | 0.00 |
| Maximum of Months | 364.63 | 34.34 | 163.01 | 63.25 | 101.52 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 218.53 | 27.26 | 95.05 | 18.01 | 77.04 | 0.00 | 0.00 |
| February | 251.20 | 18.55 | 104.66 | 21.91 | 82.76 | 0.00 | 0.00 |
| March | 280.57 | 9.95 | 111.51 | 25.67 | 85.84 | 0.00 | 0.00 |
| April | 309.79 | 2.39 | 116.83 | 26.30 | 90.53 | 0.00 | 0.00 |
| May | 330.83 | 4.66 | 121.08 | 24.23 | 96.85 | 0.00 | 0.00 |
| June | 366.59 | 5.10 | 138.57 | 35.56 | 103.01 | 0.00 | 0.00 |
| July | 289.68 | 11.38 | 118.81 | 18.46 | 100.34 | 0.00 | 0.00 |
| August | 272.05 | 7.98 | 112.74 | 19.49 | 93.25 | 0.00 | 0.00 |
| September | 252.97 | 7.84 | 100.77 | 14.70 | 86.07 | 0.00 | 0.00 |
| October | 224.47 | 11.16 | 95.66 | 12.92 | 82.74 | 0.00 | 0.00 |
| November | 215.03 | 16.87 | 91.64 | 13.51 | 78.13 | 0.00 | 0.00 |
| December | 206.43 | 32.88 | 90.44 | 15.99 | 74.45 | 0.00 | 0.00 |
| Annual Sum or Average | 268.12 | 13.01 | 108.13 | 20.53 | 87.60 | 0.00 | 0.00 |
| Minimum of Months | 206.43 | 2.39 | 90.44 | 12.92 | 74.45 | 0.00 | 0.00 |
| Maximum of Months | 366.59 | 32.88 | 138.57 | 35.56 | 103.01 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 103.33 | 17.26 | 41.84 | 0.00 | 41.84 | 0.00 | 0.00 |
| February | 116.74 | 11.63 | 44.64 | 0.00 | 44.64 | 0.00 | 0.00 |
| March | 128.40 | 6.07 | 45.85 | 0.01 | 45.84 | 0.00 | 0.00 |
| April | 149.50 | 1.35 | 50.50 | 0.95 | 49.54 | 0.00 | 0.00 |
| May | 186.69 | 2.60 | 64.09 | 6.99 | 57.10 | 0.00 | 0.00 |
| June | 216.87 | 2.86 | 77.83 | 15.54 | 62.29 | 0.00 | 0.00 |
| July | 169.58 | 6.47 | 66.90 | 6.81 | 60.09 | 0.00 | 0.00 |
| August | 143.00 | 4.55 | 55.69 | 2.74 | 52.95 | 0.00 | 0.00 |
| September | 127.15 | 4.43 | 47.14 | 0.07 | 47.07 | 0.00 | 0.00 |
| October | 112.41 | 6.38 | 45.34 | 0.00 | 45.34 | 0.00 | 0.00 |
| November | 106.63 | 10.02 | 42.90 | 0.00 | 42.90 | 0.00 | 0.00 |
| December | 99.02 | 20.48 | 40.65 | 0.00 | 40.65 | 0.00 | 0.00 |
| Annual Sum or Average | 138.33 | 7.84 | 51.98 | 2.77 | 49.21 | 0.00 | 0.00 |
| Minimum of Months | 99.02 | 1.35 | 40.65 | 0.00 | 40.65 | 0.00 | 0.00 |
| Maximum of Months | 216.87 | 20.48 | 77.83 | 15.54 | 62.29 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 103.31 | 17.26 | 41.84 | 0.00 | 41.84 | 0.00 | 0.00 |
| February | 116.73 | 11.62 | 44.64 | 0.00 | 44.64 | 0.00 | 0.00 |
| March | 128.40 | 6.07 | 45.85 | 0.01 | 45.84 | 0.00 | 0.00 |
| April | 149.50 | 1.35 | 50.50 | 0.95 | 49.54 | 0.00 | 0.00 |
| May | 186.69 | 2.60 | 64.09 | 6.99 | 57.10 | 0.00 | 0.00 |
| June | 216.87 | 2.86 | 77.83 | 15.54 | 62.29 | 0.00 | 0.00 |
| July | 169.58 | 6.47 | 66.90 | 6.81 | 60.09 | 0.00 | 0.00 |
| August | 142.99 | 4.55 | 55.69 | 2.74 | 52.95 | 0.00 | 0.00 |
| September | 127.15 | 4.43 | 47.14 | 0.07 | 47.07 | 0.00 | 0.00 |
| October | 112.41 | 6.38 | 45.34 | 0.00 | 45.34 | 0.00 | 0.00 |
| November | 106.62 | 10.01 | 42.90 | 0.00 | 42.90 | 0.00 | 0.00 |
| December | 99.01 | 20.48 | 40.65 | 0.00 | 40.65 | 0.00 | 0.00 |
| Annual Sum or Average | 138.32 | 7.84 | 51.98 | 2.77 | 49.21 | 0.00 | 0.00 |
| Minimum of Months | 99.01 | 1.35 | 40.65 | 0.00 | 40.65 | 0.00 | 0.00 |
| Maximum of Months | 216.87 | 20.48 | 77.83 | 15.54 | 62.29 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 247.22 | 16.73 | 109.81 | 45.24 | 64.57 | 0.00 | 0.00 |
| February | 230.76 | 11.14 | 94.92 | 31.52 | 63.40 | 0.00 | 0.00 |
| March | 176.51 | 5.49 | 64.43 | 8.88 | 55.55 | 0.00 | 0.00 |
| April | 147.26 | 1.33 | 48.48 | 0.51 | 47.97 | 0.00 | 0.00 |
| May | 149.11 | 2.42 | 47.90 | 0.00 | 47.90 | 0.00 | 0.00 |
| June | 147.10 | 2.67 | 47.72 | 0.00 | 47.72 | 0.00 | 0.00 |
| July | 128.46 | 6.10 | 49.16 | 0.00 | 49.16 | 0.00 | 0.00 |
| August | 125.01 | 4.12 | 47.82 | 0.03 | 47.79 | 0.00 | 0.00 |
| September | 140.73 | 4.45 | 52.74 | 1.45 | 51.29 | 0.00 | 0.00 |
| October | 165.23 | 6.78 | 68.88 | 10.61 | 58.27 | 0.00 | 0.00 |
| November | 209.59 | 10.55 | 91.06 | 28.40 | 62.66 | 0.00 | 0.00 |
| December | 243.86 | 20.53 | 110.39 | 46.77 | 63.62 | 0.00 | 0.00 |
| Annual Sum or Average | 175.61 | 7.70 | 69.34 | 14.39 | 54.95 | 0.00 | 0.00 |
| Minimum of Months | 125.01 | 1.33 | 47.72 | 0.00 | 47.72 | 0.00 | 0.00 |
| Maximum of Months | 247.22 | 20.53 | 110.39 | 46.77 | 64.57 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 247.20 | 16.73 | 109.81 | 45.24 | 64.57 | 0.00 | 0.00 |
| February | 230.75 | 11.14 | 94.92 | 31.52 | 63.40 | 0.00 | 0.00 |
| March | 176.50 | 5.48 | 64.43 | 8.88 | 55.55 | 0.00 | 0.00 |
| April | 147.26 | 1.33 | 48.48 | 0.51 | 47.97 | 0.00 | 0.00 |
| May | 149.10 | 2.42 | 47.90 | 0.00 | 47.90 | 0.00 | 0.00 |
| June | 147.09 | 2.67 | 47.72 | 0.00 | 47.72 | 0.00 | 0.00 |
| July | 128.45 | 6.10 | 49.16 | 0.00 | 49.16 | 0.00 | 0.00 |
| August | 125.00 | 4.12 | 47.82 | 0.03 | 47.79 | 0.00 | 0.00 |
| September | 140.72 | 4.45 | 52.74 | 1.45 | 51.29 | 0.00 | 0.00 |
| October | 165.22 | 6.77 | 68.88 | 10.61 | 58.27 | 0.00 | 0.00 |
| November | 209.58 | 10.55 | 91.06 | 28.40 | 62.66 | 0.00 | 0.00 |
| December | 243.84 | 20.53 | 110.39 | 46.77 | 63.62 | 0.00 | 0.00 |
| Annual Sum or Average | 175.61 | 7.69 | 69.34 | 14.39 | 54.95 | 0.00 | 0.00 |
| Minimum of Months | 125.00 | 1.33 | 47.72 | 0.00 | 47.72 | 0.00 | 0.00 |
| Maximum of Months | 247.20 | 20.53 | 110.39 | 46.77 | 64.57 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 357.75 | 28.09 | 163.73 | 64.28 | 99.45 | 0.00 | 0.00 |
| February | 355.95 | 18.73 | 154.00 | 52.43 | 101.57 | 0.00 | 0.00 |
| March | 321.73 | 10.04 | 130.69 | 35.07 | 95.62 | 0.00 | 0.00 |
| April | 298.02 | 2.31 | 114.94 | 25.92 | 89.02 | 0.00 | 0.00 |
| May | 284.23 | 4.43 | 104.51 | 16.77 | 87.74 | 0.00 | 0.00 |
| June | 290.34 | 4.93 | 109.05 | 21.12 | 87.93 | 0.00 | 0.00 |
| July | 243.03 | 10.98 | 101.50 | 12.35 | 89.14 | 0.00 | 0.00 |
| August | 246.56 | 7.33 | 104.75 | 16.91 | 87.84 | 0.00 | 0.00 |
| September | 257.66 | 8.08 | 105.96 | 16.18 | 89.78 | 0.00 | 0.00 |
| October | 269.16 | 11.93 | 118.91 | 23.50 | 95.41 | 0.00 | 0.00 |
| November | 310.23 | 17.65 | 139.78 | 41.64 | 98.14 | 0.00 | 0.00 |
| December | 345.74 | 33.95 | 160.35 | 63.13 | 97.22 | 0.00 | 0.00 |
| Annual Sum or Average | 298.00 | 13.21 | 125.54 | 32.35 | 93.19 | 0.00 | 0.00 |
| Minimum of Months | 243.03 | 2.31 | 101.50 | 12.35 | 87.74 | 0.00 | 0.00 |
| Maximum of Months | 357.75 | 33.95 | 163.73 | 64.28 | 101.57 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 217.11 | 28.79 | 95.77 | 19.04 | 76.73 | 0.00 | 0.00 |
| February | 244.69 | 19.48 | 103.71 | 20.91 | 82.80 | 0.00 | 0.00 |
| March | 274.87 | 10.74 | 112.11 | 26.20 | 85.90 | 0.00 | 0.00 |
| April | 300.16 | 2.36 | 116.96 | 26.35 | 90.60 | 0.00 | 0.00 |
| May | 320.90 | 4.63 | 120.71 | 23.76 | 96.94 | 0.00 | 0.00 |
| June | 358.54 | 5.12 | 139.15 | 36.66 | 102.49 | 0.00 | 0.00 |
| July | 283.13 | 11.38 | 119.24 | 19.16 | 100.08 | 0.00 | 0.00 |
| August | 264.16 | 7.78 | 112.62 | 19.62 | 93.00 | 0.00 | 0.00 |
| September | 244.46 | 8.06 | 100.36 | 14.79 | 85.57 | 0.00 | 0.00 |
| October | 217.56 | 11.50 | 95.37 | 12.89 | 82.48 | 0.00 | 0.00 |
| November | 209.54 | 17.13 | 91.62 | 13.24 | 78.38 | 0.00 | 0.00 |
| December | 204.23 | 33.98 | 90.61 | 16.36 | 74.25 | 0.00 | 0.00 |
| Annual Sum or Average | 261.57 | 13.42 | 108.18 | 20.73 | 87.45 | 0.00 | 0.00 |
| Minimum of Months | 204.23 | 2.36 | 90.61 | 12.89 | 74.25 | 0.00 | 0.00 |
| Maximum of Months | 358.54 | 33.98 | 139.15 | 36.66 | 102.49 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 354.73 | 27.16 | 163.01 | 63.25 | 99.76 | 0.00 | 0.00 |
| February | 356.79 | 17.88 | 154.95 | 53.43 | 101.52 | 0.00 | 0.00 |
| March | 320.22 | 8.99 | 130.09 | 34.54 | 95.55 | 0.00 | 0.00 |
| April | 299.56 | 2.24 | 114.81 | 25.86 | 88.95 | 0.00 | 0.00 |
| May | 285.97 | 4.41 | 104.89 | 17.23 | 87.65 | 0.00 | 0.00 |
| June | 289.66 | 4.81 | 108.47 | 20.02 | 88.45 | 0.00 | 0.00 |
| July | 242.20 | 10.83 | 101.06 | 11.65 | 89.41 | 0.00 | 0.00 |
| August | 247.45 | 7.34 | 104.87 | 16.78 | 88.09 | 0.00 | 0.00 |
| September | 259.29 | 7.95 | 106.38 | 16.09 | 90.29 | 0.00 | 0.00 |
| October | 270.11 | 11.73 | 119.20 | 23.53 | 95.68 | 0.00 | 0.00 |
| November | 310.18 | 17.43 | 139.80 | 41.91 | 97.89 | 0.00 | 0.00 |
| December | 343.83 | 33.28 | 160.18 | 62.76 | 97.42 | 0.00 | 0.00 |
| Annual Sum or Average | 297.95 | 12.85 | 125.49 | 32.15 | 93.34 | 0.00 | 0.00 |
| Minimum of Months | 242.20 | 2.24 | 101.06 | 11.65 | 87.65 | 0.00 | 0.00 |
| Maximum of Months | 356.79 | 33.28 | 163.01 | 63.25 | 101.52 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 212.60 | 26.53 | 95.05 | 18.01 | 77.04 | 0.00 | 0.00 |
| February | 244.60 | 17.80 | 104.66 | 21.91 | 82.76 | 0.00 | 0.00 |
| March | 273.24 | 9.56 | 111.51 | 25.67 | 85.84 | 0.00 | 0.00 |
| April | 301.66 | 2.27 | 116.83 | 26.30 | 90.53 | 0.00 | 0.00 |
| May | 322.67 | 4.63 | 121.08 | 24.23 | 96.85 | 0.00 | 0.00 |
| June | 357.98 | 5.09 | 138.57 | 35.56 | 103.01 | 0.00 | 0.00 |
| July | 282.38 | 11.32 | 118.81 | 18.46 | 100.34 | 0.00 | 0.00 |
| August | 265.16 | 7.87 | 112.74 | 19.49 | 93.25 | 0.00 | 0.00 |
| September | 246.10 | 7.94 | 100.77 | 14.70 | 86.07 | 0.00 | 0.00 |
| October | 218.44 | 11.24 | 95.66 | 12.92 | 82.74 | 0.00 | 0.00 |
| November | 209.15 | 16.60 | 91.64 | 13.51 | 78.13 | 0.00 | 0.00 |
| December | 200.99 | 32.08 | 90.44 | 15.99 | 74.45 | 0.00 | 0.00 |
| Annual Sum or Average | 261.19 | 12.75 | 108.13 | 20.53 | 87.60 | 0.00 | 0.00 |
| Minimum of Months | 200.99 | 2.27 | 90.44 | 12.92 | 74.45 | 0.00 | 0.00 |
| Maximum of Months | 357.98 | 32.08 | 138.57 | 35.56 | 103.01 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 100.43 | 17.07 | 41.84 | 0.00 | 41.84 | 0.00 | 0.00 |
| February | 113.55 | 11.45 | 44.64 | 0.00 | 44.64 | 0.00 | 0.00 |
| March | 124.84 | 6.10 | 45.85 | 0.01 | 45.84 | 0.00 | 0.00 |
| April | 145.32 | 1.35 | 50.50 | 0.95 | 49.54 | 0.00 | 0.00 |
| May | 182.43 | 2.71 | 64.09 | 6.99 | 57.10 | 0.00 | 0.00 |
| June | 212.36 | 2.98 | 77.83 | 15.54 | 62.29 | 0.00 | 0.00 |
| July | 165.78 | 6.66 | 66.90 | 6.81 | 60.09 | 0.00 | 0.00 |
| August | 139.47 | 4.66 | 55.69 | 2.74 | 52.95 | 0.00 | 0.00 |
| September | 123.64 | 4.68 | 47.14 | 0.07 | 47.07 | 0.00 | 0.00 |
| October | 109.38 | 6.67 | 45.34 | 0.00 | 45.34 | 0.00 | 0.00 |
| November | 103.70 | 10.11 | 42.90 | 0.00 | 42.90 | 0.00 | 0.00 |
| December | 96.36 | 20.27 | 40.65 | 0.00 | 40.65 | 0.00 | 0.00 |
| Annual Sum or Average | 134.82 | 7.90 | 51.98 | 2.77 | 49.21 | 0.00 | 0.00 |
| Minimum of Months | 96.36 | 1.35 | 40.65 | 0.00 | 40.65 | 0.00 | 0.00 |
| Maximum of Months | 212.36 | 20.27 | 77.83 | 15.54 | 62.29 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 100.39 | 17.06 | 41.84 | 0.00 | 41.84 | 0.00 | 0.00 |
| February | 113.52 | 11.44 | 44.64 | 0.00 | 44.64 | 0.00 | 0.00 |
| March | 124.84 | 6.09 | 45.85 | 0.01 | 45.84 | 0.00 | 0.00 |
| April | 145.32 | 1.35 | 50.50 | 0.95 | 49.54 | 0.00 | 0.00 |
| May | 182.42 | 2.70 | 64.09 | 6.99 | 57.10 | 0.00 | 0.00 |
| June | 212.35 | 2.98 | 77.83 | 15.54 | 62.29 | 0.00 | 0.00 |
| July | 165.77 | 6.65 | 66.90 | 6.81 | 60.09 | 0.00 | 0.00 |
| August | 139.46 | 4.65 | 55.69 | 2.74 | 52.95 | 0.00 | 0.00 |
| September | 123.63 | 4.67 | 47.14 | 0.07 | 47.07 | 0.00 | 0.00 |
| October | 109.37 | 6.66 | 45.34 | 0.00 | 45.34 | 0.00 | 0.00 |
| November | 103.68 | 10.10 | 42.90 | 0.00 | 42.90 | 0.00 | 0.00 |
| December | 96.33 | 20.26 | 40.65 | 0.00 | 40.65 | 0.00 | 0.00 |
| Annual Sum or Average | 134.80 | 7.89 | 51.98 | 2.77 | 49.21 | 0.00 | 0.00 |
| Minimum of Months | 96.33 | 1.35 | 40.65 | 0.00 | 40.65 | 0.00 | 0.00 |
| Maximum of Months | 212.35 | 20.26 | 77.83 | 15.54 | 62.29 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 243.35 | 16.39 | 109.81 | 45.24 | 64.57 | 0.00 | 0.00 |
| February | 226.77 | 10.76 | 94.92 | 31.52 | 63.40 | 0.00 | 0.00 |
| March | 172.57 | 5.38 | 64.43 | 8.88 | 55.55 | 0.00 | 0.00 |
| April | 143.20 | 1.33 | 48.48 | 0.51 | 47.97 | 0.00 | 0.00 |
| May | 145.18 | 2.55 | 47.90 | 0.00 | 47.90 | 0.00 | 0.00 |
| June | 143.08 | 2.83 | 47.72 | 0.00 | 47.72 | 0.00 | 0.00 |
| July | 125.03 | 6.32 | 49.16 | 0.00 | 49.16 | 0.00 | 0.00 |
| August | 121.58 | 4.23 | 47.82 | 0.03 | 47.79 | 0.00 | 0.00 |
| September | 137.08 | 4.69 | 52.74 | 1.45 | 51.29 | 0.00 | 0.00 |
| October | 161.75 | 7.00 | 68.88 | 10.61 | 58.27 | 0.00 | 0.00 |
| November | 205.94 | 10.51 | 91.06 | 28.40 | 62.66 | 0.00 | 0.00 |
| December | 240.23 | 20.21 | 110.39 | 46.77 | 63.62 | 0.00 | 0.00 |
| Annual Sum or Average | 171.86 | 7.69 | 69.34 | 14.39 | 54.95 | 0.00 | 0.00 |
| Minimum of Months | 121.58 | 1.33 | 47.72 | 0.00 | 47.72 | 0.00 | 0.00 |
| Maximum of Months | 243.35 | 20.21 | 110.39 | 46.77 | 64.57 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 243.33 | 16.38 | 109.81 | 45.24 | 64.57 | 0.00 | 0.00 |
| February | 226.74 | 10.75 | 94.92 | 31.52 | 63.40 | 0.00 | 0.00 |
| March | 172.57 | 5.37 | 64.43 | 8.88 | 55.55 | 0.00 | 0.00 |
| April | 143.20 | 1.33 | 48.48 | 0.51 | 47.97 | 0.00 | 0.00 |
| May | 145.18 | 2.55 | 47.90 | 0.00 | 47.90 | 0.00 | 0.00 |
| June | 143.07 | 2.83 | 47.72 | 0.00 | 47.72 | 0.00 | 0.00 |
| July | 125.02 | 6.31 | 49.16 | 0.00 | 49.16 | 0.00 | 0.00 |
| August | 121.56 | 4.23 | 47.82 | 0.03 | 47.79 | 0.00 | 0.00 |
| September | 137.07 | 4.68 | 52.74 | 1.45 | 51.29 | 0.00 | 0.00 |
| October | 161.74 | 6.99 | 68.88 | 10.61 | 58.27 | 0.00 | 0.00 |
| November | 205.93 | 10.51 | 91.06 | 28.40 | 62.66 | 0.00 | 0.00 |
| December | 240.20 | 20.20 | 110.39 | 46.77 | 63.62 | 0.00 | 0.00 |
| Annual Sum or Average | 171.85 | 7.68 | 69.34 | 14.39 | 54.95 | 0.00 | 0.00 |
| Minimum of Months | 121.56 | 1.33 | 47.72 | 0.00 | 47.72 | 0.00 | 0.00 |
| Maximum of Months | 243.33 | 20.20 | 110.39 | 46.77 | 64.57 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 25.80 | 4.13 | 12.77 | 4.32 | 8.44 | 0.00 | 0.00 |
| February | 30.19 | 3.12 | 14.40 | 5.26 | 9.15 | 0.00 | 0.00 |
| March | 33.93 | 2.12 | 15.76 | 6.16 | 9.60 | 0.00 | 0.00 |
| April | 35.23 | 0.83 | 15.92 | 6.08 | 9.83 | 0.00 | 0.00 |
| May | 31.47 | 1.24 | 13.67 | 4.14 | 9.54 | 0.00 | 0.00 |
| June | 32.98 | 1.35 | 14.58 | 4.80 | 9.77 | 0.00 | 0.00 |
| July | 26.47 | 2.39 | 12.45 | 2.80 | 9.66 | 0.00 | 0.00 |
| August | 28.60 | 2.05 | 13.69 | 4.02 | 9.67 | 0.00 | 0.00 |
| September | 27.69 | 2.01 | 12.87 | 3.51 | 9.36 | 0.00 | 0.00 |
| October | 24.54 | 2.60 | 12.07 | 3.10 | 8.97 | 0.00 | 0.00 |
| November | 23.79 | 3.11 | 11.70 | 3.24 | 8.45 | 0.00 | 0.00 |
| December | 24.01 | 4.78 | 11.95 | 3.84 | 8.11 | 0.00 | 0.00 |
| Annual Sum or Average | 28.70 | 2.48 | 13.47 | 4.26 | 9.21 | 0.00 | 0.00 |
| Minimum of Months | 23.79 | 0.83 | 11.70 | 2.80 | 8.11 | 0.00 | 0.00 |
| Maximum of Months | 35.23 | 4.78 | 15.92 | 6.16 | 9.83 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 73.63 | 16.66 | 38.02 | 12.87 | 25.15 | 0.00 | 0.00 |
| February | 86.03 | 13.94 | 42.90 | 15.66 | 27.24 | 0.00 | 0.00 |
| March | 96.71 | 10.93 | 46.93 | 18.34 | 28.58 | 0.00 | 0.00 |
| April | 99.60 | 6.25 | 47.40 | 18.12 | 29.29 | 0.00 | 0.00 |
| May | 87.78 | 6.91 | 40.73 | 12.32 | 28.41 | 0.00 | 0.00 |
| June | 92.89 | 7.59 | 43.41 | 14.31 | 29.10 | 0.00 | 0.00 |
| July | 74.75 | 10.74 | 37.09 | 8.33 | 28.76 | 0.00 | 0.00 |
| August | 80.89 | 9.96 | 40.77 | 11.97 | 28.80 | 0.00 | 0.00 |
| September | 78.31 | 9.63 | 38.33 | 10.46 | 27.87 | 0.00 | 0.00 |
| October | 69.49 | 11.64 | 35.96 | 9.23 | 26.73 | 0.00 | 0.00 |
| November | 67.56 | 13.24 | 34.83 | 9.66 | 25.18 | 0.00 | 0.00 |
| December | 68.46 | 18.45 | 35.58 | 11.43 | 24.15 | 0.00 | 0.00 |
| Annual Sum or Average | 81.27 | 11.33 | 40.13 | 12.70 | 27.44 | 0.00 | 0.00 |
| Minimum of Months | 67.56 | 6.25 | 34.83 | 8.33 | 24.15 | 0.00 | 0.00 |
| Maximum of Months | 99.60 | 18.45 | 47.40 | 18.34 | 29.29 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 26.25 | 4.11 | 12.77 | 4.32 | 8.44 | 0.00 | 0.00 |
| February | 30.74 | 3.13 | 14.40 | 5.26 | 9.15 | 0.00 | 0.00 |
| March | 34.60 | 2.06 | 15.76 | 6.16 | 9.60 | 0.00 | 0.00 |
| April | 36.11 | 0.81 | 15.92 | 6.08 | 9.83 | 0.00 | 0.00 |
| May | 32.33 | 1.16 | 13.67 | 4.14 | 9.54 | 0.00 | 0.00 |
| June | 33.84 | 1.25 | 14.58 | 4.80 | 9.77 | 0.00 | 0.00 |
| July | 27.08 | 2.28 | 12.45 | 2.80 | 9.66 | 0.00 | 0.00 |
| August | 29.18 | 1.93 | 13.69 | 4.02 | 9.67 | 0.00 | 0.00 |
| September | 28.33 | 1.88 | 12.87 | 3.51 | 9.36 | 0.00 | 0.00 |
| October | 25.07 | 2.48 | 12.07 | 3.10 | 8.97 | 0.00 | 0.00 |
| November | 24.28 | 3.03 | 11.70 | 3.24 | 8.45 | 0.00 | 0.00 |
| December | 24.40 | 4.77 | 11.95 | 3.84 | 8.11 | 0.00 | 0.00 |
| Annual Sum or Average | 29.33 | 2.41 | 13.47 | 4.26 | 9.21 | 0.00 | 0.00 |
| Minimum of Months | 24.28 | 0.81 | 11.70 | 2.80 | 8.11 | 0.00 | 0.00 |
| Maximum of Months | 36.11 | 4.77 | 15.92 | 6.16 | 9.83 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.971224E+09 | 86218733.05 | 0.438547E+09 | 0.172170E+09 | 0.266378E+09 | 0.00 | 0.00 |
| February | 0.872881E+09 | 55681942.96 | 0.372558E+09 | 0.126843E+09 | 0.245715E+09 | 0.00 | 0.00 |
| March | 0.872815E+09 | 34569387.94 | 0.350034E+09 | 93934357.27 | 0.256100E+09 | 0.00 | 0.00 |
| April | 0.778501E+09 | 8250664.83 | 0.297920E+09 | 67174140.34 | 0.230746E+09 | 0.00 | 0.00 |
| May | 0.766590E+09 | 15291457.33 | 0.279927E+09 | 44914133.92 | 0.235013E+09 | 0.00 | 0.00 |
| June | 0.756919E+09 | 15943424.76 | 0.282649E+09 | 54734314.60 | 0.227914E+09 | 0.00 | 0.00 |
| July | 0.658577E+09 | 36422766.68 | 0.271855E+09 | 33089957.42 | 0.238765E+09 | 0.00 | 0.00 |
| August | 0.665649E+09 | 25898631.23 | 0.280553E+09 | 45290254.48 | 0.235263E+09 | 0.00 | 0.00 |
| September | 0.675112E+09 | 26481280.39 | 0.274647E+09 | 41936740.99 | 0.232711E+09 | 0.00 | 0.00 |
| October | 0.731000E+09 | 38883814.16 | 0.318498E+09 | 62939955.70 | 0.255558E+09 | 0.00 | 0.00 |
| November | 0.815059E+09 | 54279148.21 | 0.362313E+09 | 0.107930E+09 | 0.254383E+09 | 0.00 | 0.00 |
| December | 0.937837E+09 | 0.102125E+09 | 0.429487E+09 | 0.169094E+09 | 0.260393E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.950216E+10 | 0.500046E+09 | 0.395899E+10 | 0.102005E+10 | 0.293894E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.658577E+09 | 8250664.83 | 0.271855E+09 | 33089957.42 | 0.227914E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.971224E+09 | 0.102125E+09 | 0.438547E+09 | 0.172170E+09 | 0.266378E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.589914E+09 | 86854145.60 | 0.256513E+09 | 51007891.94 | 0.205505E+09 | 0.00 | 0.00 |
| February | 0.600384E+09 | 56124481.94 | 0.250902E+09 | 50583646.60 | 0.200318E+09 | 0.00 | 0.00 |
| March | 0.746072E+09 | 35545371.77 | 0.300262E+09 | 70183091.07 | 0.230079E+09 | 0.00 | 0.00 |
| April | 0.785259E+09 | 8575990.84 | 0.303149E+09 | 68311648.65 | 0.234837E+09 | 0.00 | 0.00 |
| May | 0.866913E+09 | 16149764.01 | 0.323305E+09 | 63649368.60 | 0.259656E+09 | 0.00 | 0.00 |
| June | 0.936735E+09 | 16874979.98 | 0.360678E+09 | 95021403.79 | 0.265656E+09 | 0.00 | 0.00 |
| July | 0.767893E+09 | 37939678.43 | 0.319373E+09 | 51330132.52 | 0.268043E+09 | 0.00 | 0.00 |
| August | 0.713784E+09 | 27213939.88 | 0.301633E+09 | 52537953.55 | 0.249096E+09 | 0.00 | 0.00 |
| September | 0.640246E+09 | 26389193.60 | 0.260126E+09 | 38339237.38 | 0.221787E+09 | 0.00 | 0.00 |
| October | 0.590515E+09 | 37280456.56 | 0.255437E+09 | 34526987.88 | 0.220910E+09 | 0.00 | 0.00 |
| November | 0.550616E+09 | 52082276.20 | 0.237479E+09 | 34315245.16 | 0.203164E+09 | 0.00 | 0.00 |
| December | 0.554070E+09 | 0.101307E+09 | 0.242686E+09 | 43820569.77 | 0.198865E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.834240E+10 | 0.502337E+09 | 0.341154E+10 | 0.653627E+09 | 0.275792E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.550616E+09 | 8575990.84 | 0.237479E+09 | 34315245.16 | 0.198865E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.936735E+09 | 0.101307E+09 | 0.360678E+09 | 95021403.79 | 0.268043E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.895007E+09 | 0.190996E+09 | 0.436618E+09 | 0.169411E+09 | 0.267208E+09 | 0.00 | 0.00 |
| February | 0.810839E+09 | 0.147143E+09 | 0.374861E+09 | 0.129257E+09 | 0.245604E+09 | 0.00 | 0.00 |
| March | 0.793730E+09 | 0.130326E+09 | 0.348444E+09 | 92517078.72 | 0.255927E+09 | 0.00 | 0.00 |
| April | 0.674406E+09 | 83585234.28 | 0.297591E+09 | 67038174.01 | 0.230553E+09 | 0.00 | 0.00 |
| May | 0.656928E+09 | 89302849.83 | 0.280929E+09 | 46161163.88 | 0.234768E+09 | 0.00 | 0.00 |
| June | 0.655395E+09 | 90788643.36 | 0.281144E+09 | 51884356.97 | 0.229260E+09 | 0.00 | 0.00 |
| July | 0.568804E+09 | 0.128908E+09 | 0.270692E+09 | 31214610.43 | 0.239477E+09 | 0.00 | 0.00 |
| August | 0.593253E+09 | 0.117101E+09 | 0.280884E+09 | 44946287.12 | 0.235938E+09 | 0.00 | 0.00 |
| September | 0.596466E+09 | 0.114825E+09 | 0.275730E+09 | 41710993.80 | 0.234019E+09 | 0.00 | 0.00 |
| October | 0.657772E+09 | 0.140138E+09 | 0.319277E+09 | 63016149.02 | 0.256261E+09 | 0.00 | 0.00 |
| November | 0.745836E+09 | 0.150114E+09 | 0.362371E+09 | 0.108641E+09 | 0.253730E+09 | 0.00 | 0.00 |
| December | 0.872669E+09 | 0.202654E+09 | 0.429024E+09 | 0.168102E+09 | 0.260923E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.852110E+10 | 0.158588E+10 | 0.395757E+10 | 0.101390E+10 | 0.294367E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.568804E+09 | 83585234.28 | 0.270692E+09 | 31214610.43 | 0.229260E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.895007E+09 | 0.202654E+09 | 0.436618E+09 | 0.169411E+09 | 0.267208E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.577855E+09 | 80270454.74 | 0.254584E+09 | 48248987.90 | 0.206335E+09 | 0.00 | 0.00 |
| February | 0.599975E+09 | 51673397.87 | 0.253205E+09 | 52997774.44 | 0.200207E+09 | 0.00 | 0.00 |
| March | 0.741447E+09 | 32451390.27 | 0.298672E+09 | 68765812.51 | 0.229906E+09 | 0.00 | 0.00 |
| April | 0.788732E+09 | 8216562.63 | 0.302820E+09 | 68175682.32 | 0.234644E+09 | 0.00 | 0.00 |
| May | 0.871612E+09 | 16144807.51 | 0.324308E+09 | 64896398.56 | 0.259411E+09 | 0.00 | 0.00 |
| June | 0.935606E+09 | 16963425.56 | 0.359173E+09 | 92171446.16 | 0.267001E+09 | 0.00 | 0.00 |
| July | 0.765700E+09 | 37872804.14 | 0.318210E+09 | 49454785.53 | 0.268755E+09 | 0.00 | 0.00 |
| August | 0.716422E+09 | 27479628.30 | 0.301965E+09 | 52193986.19 | 0.249771E+09 | 0.00 | 0.00 |
| September | 0.644282E+09 | 26148785.34 | 0.261209E+09 | 38113490.19 | 0.223095E+09 | 0.00 | 0.00 |
| October | 0.592882E+09 | 36575655.28 | 0.256216E+09 | 34603181.21 | 0.221612E+09 | 0.00 | 0.00 |
| November | 0.549571E+09 | 50501466.74 | 0.237537E+09 | 35025750.75 | 0.202511E+09 | 0.00 | 0.00 |
| December | 0.545452E+09 | 95675299.35 | 0.242223E+09 | 42828667.37 | 0.199395E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.832954E+10 | 0.479974E+09 | 0.341012E+10 | 0.647476E+09 | 0.276264E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.545452E+09 | 8216562.63 | 0.237537E+09 | 34603181.21 | 0.199395E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.935606E+09 | 95675299.35 | 0.359173E+09 | 92171446.16 | 0.268755E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.272648E+09 | 50193636.52 | 0.112074E+09 | 0.00 | 0.112074E+09 | 0.00 | 0.00 |
| February | 0.278145E+09 | 31727504.04 | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.00 | 0.00 |
| March | 0.338213E+09 | 19217307.52 | 0.122797E+09 | 21683.77 | 0.122775E+09 | 0.00 | 0.00 |
| April | 0.379804E+09 | 4492150.03 | 0.130886E+09 | 2466740.50 | 0.128420E+09 | 0.00 | 0.00 |
| May | 0.492532E+09 | 8819113.24 | 0.171666E+09 | 18735234.68 | 0.152931E+09 | 0.00 | 0.00 |
| June | 0.554763E+09 | 9229786.49 | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.00 | 0.00 |
| July | 0.449167E+09 | 20980607.69 | 0.179198E+09 | 18240175.10 | 0.160958E+09 | 0.00 | 0.00 |
| August | 0.376576E+09 | 15137428.88 | 0.149152E+09 | 7326383.82 | 0.141826E+09 | 0.00 | 0.00 |
| September | 0.323510E+09 | 14279030.84 | 0.122176E+09 | 168559.27 | 0.122007E+09 | 0.00 | 0.00 |
| October | 0.296472E+09 | 20525013.38 | 0.121434E+09 | 0.00 | 0.121434E+09 | 0.00 | 0.00 |
| November | 0.272103E+09 | 29550458.43 | 0.111197E+09 | 0.00 | 0.111197E+09 | 0.00 | 0.00 |
| December | 0.261159E+09 | 58991300.66 | 0.108878E+09 | 0.00 | 0.108878E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.429509E+10 | 0.283143E+09 | 0.163917E+10 | 87245866.33 | 0.155193E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.261159E+09 | 4492150.03 | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.554763E+09 | 58991300.66 | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.272609E+09 | 50188863.29 | 0.112074E+09 | 0.00 | 0.112074E+09 | 0.00 | 0.00 |
| February | 0.278114E+09 | 31721214.27 | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.00 | 0.00 |
| March | 0.338208E+09 | 19203574.62 | 0.122797E+09 | 21683.77 | 0.122775E+09 | 0.00 | 0.00 |
| April | 0.379797E+09 | 4488739.70 | 0.130886E+09 | 2466740.50 | 0.128420E+09 | 0.00 | 0.00 |
| May | 0.492518E+09 | 8815400.28 | 0.171666E+09 | 18735234.68 | 0.152931E+09 | 0.00 | 0.00 |
| June | 0.554748E+09 | 9229271.68 | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.00 | 0.00 |
| July | 0.449150E+09 | 20974736.79 | 0.179198E+09 | 18240175.10 | 0.160958E+09 | 0.00 | 0.00 |
| August | 0.376554E+09 | 15134457.11 | 0.149152E+09 | 7326383.82 | 0.141826E+09 | 0.00 | 0.00 |
| September | 0.323489E+09 | 14277637.01 | 0.122176E+09 | 168559.27 | 0.122007E+09 | 0.00 | 0.00 |
| October | 0.296461E+09 | 20519092.49 | 0.121434E+09 | 0.00 | 0.121434E+09 | 0.00 | 0.00 |
| November | 0.272086E+09 | 29548262.78 | 0.111197E+09 | 0.00 | 0.111197E+09 | 0.00 | 0.00 |
| December | 0.261128E+09 | 58984252.52 | 0.108878E+09 | 0.00 | 0.108878E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.429486E+10 | 0.283086E+09 | 0.163917E+10 | 87245866.33 | 0.155193E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.261128E+09 | 4488739.70 | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.554748E+09 | 58984252.52 | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.659086E+09 | 49410047.71 | 0.294108E+09 | 0.121162E+09 | 0.172946E+09 | 0.00 | 0.00 |
| February | 0.554496E+09 | 31069212.75 | 0.229638E+09 | 76259171.80 | 0.153379E+09 | 0.00 | 0.00 |
| March | 0.466878E+09 | 18112249.99 | 0.172569E+09 | 23772949.97 | 0.148796E+09 | 0.00 | 0.00 |
| April | 0.372922E+09 | 4359860.55 | 0.125658E+09 | 1329232.19 | 0.124329E+09 | 0.00 | 0.00 |
| May | 0.390653E+09 | 8236038.68 | 0.128288E+09 | 0.00 | 0.128288E+09 | 0.00 | 0.00 |
| June | 0.372236E+09 | 8615450.90 | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.00 | 0.00 |
| July | 0.338200E+09 | 19904221.41 | 0.131680E+09 | 0.00 | 0.131680E+09 | 0.00 | 0.00 |
| August | 0.327609E+09 | 14054799.59 | 0.128072E+09 | 78684.75 | 0.127993E+09 | 0.00 | 0.00 |
| September | 0.358698E+09 | 14397648.84 | 0.136697E+09 | 3766062.87 | 0.132931E+09 | 0.00 | 0.00 |
| October | 0.438518E+09 | 21771996.81 | 0.184496E+09 | 28412967.82 | 0.156083E+09 | 0.00 | 0.00 |
| November | 0.539771E+09 | 31207188.23 | 0.236031E+09 | 73614914.47 | 0.162416E+09 | 0.00 | 0.00 |
| December | 0.650247E+09 | 59589016.08 | 0.295679E+09 | 0.125273E+09 | 0.170406E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.546932E+10 | 0.280728E+09 | 0.218662E+10 | 0.453669E+09 | 0.173295E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.327609E+09 | 4359860.55 | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.659086E+09 | 59589016.08 | 0.295679E+09 | 0.125273E+09 | 0.172946E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.656558E+09 | 51442669.58 | 0.294108E+09 | 0.121162E+09 | 0.172946E+09 | 0.00 | 0.00 |
| February | 0.552237E+09 | 32758815.92 | 0.229638E+09 | 76259171.80 | 0.153379E+09 | 0.00 | 0.00 |
| March | 0.464133E+09 | 19537646.43 | 0.172569E+09 | 23772949.97 | 0.148796E+09 | 0.00 | 0.00 |
| April | 0.369120E+09 | 4862664.71 | 0.125658E+09 | 1329232.19 | 0.124329E+09 | 0.00 | 0.00 |
| May | 0.386926E+09 | 9046234.94 | 0.128288E+09 | 0.00 | 0.128288E+09 | 0.00 | 0.00 |
| June | 0.368780E+09 | 9433957.62 | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.00 | 0.00 |
| July | 0.335479E+09 | 21532738.42 | 0.131680E+09 | 0.00 | 0.131680E+09 | 0.00 | 0.00 |
| August | 0.324688E+09 | 15353019.90 | 0.128072E+09 | 78684.75 | 0.127993E+09 | 0.00 | 0.00 |
| September | 0.355906E+09 | 15735286.61 | 0.136697E+09 | 3766062.87 | 0.132931E+09 | 0.00 | 0.00 |
| October | 0.435996E+09 | 23637135.44 | 0.184496E+09 | 28412967.82 | 0.156083E+09 | 0.00 | 0.00 |
| November | 0.537417E+09 | 32975228.54 | 0.236031E+09 | 73614914.47 | 0.162416E+09 | 0.00 | 0.00 |
| December | 0.648068E+09 | 61495184.60 | 0.295679E+09 | 0.125273E+09 | 0.170406E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.543531E+10 | 0.297811E+09 | 0.218662E+10 | 0.453669E+09 | 0.173295E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.324688E+09 | 4862664.71 | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.656558E+09 | 61495184.60 | 0.295679E+09 | 0.125273E+09 | 0.172946E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.977244E+09 | 77659443.28 | 0.438547E+09 | 0.172170E+09 | 0.266378E+09 | 0.00 | 0.00 |
| February | 0.879520E+09 | 47710531.76 | 0.372558E+09 | 0.126843E+09 | 0.245715E+09 | 0.00 | 0.00 |
| March | 0.882454E+09 | 28156790.32 | 0.350034E+09 | 93934357.27 | 0.256100E+09 | 0.00 | 0.00 |
| April | 0.793078E+09 | 6299732.93 | 0.297920E+09 | 67174140.34 | 0.230746E+09 | 0.00 | 0.00 |
| May | 0.781771E+09 | 11788685.00 | 0.279927E+09 | 44914133.92 | 0.235013E+09 | 0.00 | 0.00 |
| June | 0.772953E+09 | 12574851.37 | 0.282649E+09 | 54734314.60 | 0.227914E+09 | 0.00 | 0.00 |
| July | 0.669132E+09 | 29266358.35 | 0.271855E+09 | 33089957.42 | 0.238765E+09 | 0.00 | 0.00 |
| August | 0.678476E+09 | 19841196.05 | 0.280553E+09 | 45290254.48 | 0.235263E+09 | 0.00 | 0.00 |
| September | 0.686228E+09 | 20660663.76 | 0.274647E+09 | 41936740.99 | 0.232711E+09 | 0.00 | 0.00 |
| October | 0.738516E+09 | 31885069.90 | 0.318498E+09 | 62939955.70 | 0.255558E+09 | 0.00 | 0.00 |
| November | 0.821973E+09 | 46931034.93 | 0.362313E+09 | 0.107930E+09 | 0.254383E+09 | 0.00 | 0.00 |
| December | 0.943902E+09 | 93375190.87 | 0.429487E+09 | 0.169094E+09 | 0.260393E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.962525E+10 | 0.426150E+09 | 0.395899E+10 | 0.102005E+10 | 0.293894E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.669132E+09 | 6299732.93 | 0.271855E+09 | 33089957.42 | 0.227914E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.977244E+09 | 93375190.87 | 0.438547E+09 | 0.172170E+09 | 0.266378E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.596832E+09 | 79112000.22 | 0.256513E+09 | 51007891.94 | 0.205505E+09 | 0.00 | 0.00 |
| February | 0.607444E+09 | 48889160.44 | 0.250902E+09 | 50583646.60 | 0.200318E+09 | 0.00 | 0.00 |
| March | 0.755335E+09 | 29455226.52 | 0.300262E+09 | 70183091.07 | 0.230079E+09 | 0.00 | 0.00 |
| April | 0.798935E+09 | 6419948.66 | 0.303149E+09 | 68311648.65 | 0.234837E+09 | 0.00 | 0.00 |
| May | 0.881272E+09 | 12434915.89 | 0.323305E+09 | 63649368.60 | 0.259656E+09 | 0.00 | 0.00 |
| June | 0.951579E+09 | 13198494.44 | 0.360678E+09 | 95021403.79 | 0.265656E+09 | 0.00 | 0.00 |
| July | 0.777967E+09 | 30510764.92 | 0.319373E+09 | 51330132.52 | 0.268043E+09 | 0.00 | 0.00 |
| August | 0.726058E+09 | 21050178.03 | 0.301633E+09 | 52537953.55 | 0.249096E+09 | 0.00 | 0.00 |
| September | 0.651483E+09 | 20525582.13 | 0.260126E+09 | 38339237.38 | 0.221787E+09 | 0.00 | 0.00 |
| October | 0.598599E+09 | 30449641.30 | 0.255437E+09 | 34526987.88 | 0.220910E+09 | 0.00 | 0.00 |
| November | 0.558192E+09 | 45099482.88 | 0.237479E+09 | 34315245.16 | 0.203164E+09 | 0.00 | 0.00 |
| December | 0.561161E+09 | 93218362.22 | 0.242686E+09 | 43820569.77 | 0.198865E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.846486E+10 | 0.430364E+09 | 0.341154E+10 | 0.653627E+09 | 0.275792E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.558192E+09 | 6419948.66 | 0.237479E+09 | 34315245.16 | 0.198865E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.951579E+09 | 93218362.22 | 0.360678E+09 | 95021403.79 | 0.268043E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.970030E+09 | 75597507.77 | 0.436618E+09 | 0.169411E+09 | 0.267208E+09 | 0.00 | 0.00 |
| February | 0.882108E+09 | 45922785.84 | 0.374861E+09 | 0.129257E+09 | 0.245604E+09 | 0.00 | 0.00 |
| March | 0.878825E+09 | 25591803.23 | 0.348444E+09 | 92517078.72 | 0.255927E+09 | 0.00 | 0.00 |
| April | 0.797178E+09 | 6098138.22 | 0.297591E+09 | 67038174.01 | 0.230553E+09 | 0.00 | 0.00 |
| May | 0.786511E+09 | 11760441.37 | 0.280929E+09 | 46161163.88 | 0.234768E+09 | 0.00 | 0.00 |
| June | 0.771226E+09 | 12320859.50 | 0.281144E+09 | 51884356.97 | 0.229260E+09 | 0.00 | 0.00 |
| July | 0.666772E+09 | 28966912.45 | 0.270692E+09 | 31214610.43 | 0.239477E+09 | 0.00 | 0.00 |
| August | 0.680806E+09 | 19949367.05 | 0.280884E+09 | 44946287.12 | 0.235938E+09 | 0.00 | 0.00 |
| September | 0.690394E+09 | 20394573.42 | 0.275730E+09 | 41710993.80 | 0.234019E+09 | 0.00 | 0.00 |
| October | 0.741308E+09 | 31519239.11 | 0.319277E+09 | 63016149.02 | 0.256261E+09 | 0.00 | 0.00 |
| November | 0.822113E+09 | 46505673.39 | 0.362371E+09 | 0.108641E+09 | 0.253730E+09 | 0.00 | 0.00 |
| December | 0.939550E+09 | 91972050.77 | 0.429024E+09 | 0.168102E+09 | 0.260923E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.962682E+10 | 0.416599E+09 | 0.395757E+10 | 0.101390E+10 | 0.294367E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.666772E+09 | 6098138.22 | 0.270692E+09 | 31214610.43 | 0.229260E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.970030E+09 | 91972050.77 | 0.436618E+09 | 0.169411E+09 | 0.267208E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.585320E+09 | 73024721.37 | 0.254584E+09 | 48248987.90 | 0.206335E+09 | 0.00 | 0.00 |
| February | 0.607706E+09 | 44882305.40 | 0.253205E+09 | 52997774.44 | 0.200207E+09 | 0.00 | 0.00 |
| March | 0.751479E+09 | 26641255.04 | 0.298672E+09 | 68765812.51 | 0.229906E+09 | 0.00 | 0.00 |
| April | 0.802969E+09 | 6189403.60 | 0.302820E+09 | 68175682.32 | 0.234644E+09 | 0.00 | 0.00 |
| May | 0.886085E+09 | 12473766.80 | 0.324308E+09 | 64896398.56 | 0.259411E+09 | 0.00 | 0.00 |
| June | 0.950195E+09 | 13214213.82 | 0.359173E+09 | 92171446.16 | 0.267001E+09 | 0.00 | 0.00 |
| July | 0.775871E+09 | 30492952.75 | 0.318210E+09 | 49454785.53 | 0.268755E+09 | 0.00 | 0.00 |
| August | 0.728659E+09 | 21374345.70 | 0.301965E+09 | 52193986.19 | 0.249771E+09 | 0.00 | 0.00 |
| September | 0.655698E+09 | 20328157.80 | 0.261209E+09 | 38113490.19 | 0.223095E+09 | 0.00 | 0.00 |
| October | 0.601211E+09 | 29902846.97 | 0.256216E+09 | 34603181.21 | 0.221612E+09 | 0.00 | 0.00 |
| November | 0.557367E+09 | 43735695.46 | 0.237537E+09 | 35025750.75 | 0.202511E+09 | 0.00 | 0.00 |
| December | 0.552893E+09 | 88072652.02 | 0.242223E+09 | 42828667.37 | 0.199395E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.845545E+10 | 0.410332E+09 | 0.341012E+10 | 0.647476E+09 | 0.276264E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.552893E+09 | 6189403.60 | 0.237537E+09 | 34603181.21 | 0.199395E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.950195E+09 | 88072652.02 | 0.359173E+09 | 92171446.16 | 0.268755E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.276764E+09 | 46223865.68 | 0.112074E+09 | 0.00 | 0.112074E+09 | 0.00 | 0.00 |
| February | 0.282426E+09 | 28124281.03 | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.00 | 0.00 |
| March | 0.343910E+09 | 16259342.68 | 0.122797E+09 | 21683.77 | 0.122775E+09 | 0.00 | 0.00 |
| April | 0.387503E+09 | 3498860.21 | 0.130886E+09 | 2466740.50 | 0.128420E+09 | 0.00 | 0.00 |
| May | 0.500033E+09 | 6954698.13 | 0.171666E+09 | 18735234.68 | 0.152931E+09 | 0.00 | 0.00 |
| June | 0.562131E+09 | 7405111.26 | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.00 | 0.00 |
| July | 0.454212E+09 | 17334176.31 | 0.179198E+09 | 18240175.10 | 0.160958E+09 | 0.00 | 0.00 |
| August | 0.383016E+09 | 12180919.78 | 0.149152E+09 | 7326383.82 | 0.141826E+09 | 0.00 | 0.00 |
| September | 0.329583E+09 | 11473610.82 | 0.122176E+09 | 168559.27 | 0.122007E+09 | 0.00 | 0.00 |
| October | 0.301082E+09 | 17086279.57 | 0.121434E+09 | 0.00 | 0.121434E+09 | 0.00 | 0.00 |
| November | 0.276379E+09 | 25962857.09 | 0.111197E+09 | 0.00 | 0.111197E+09 | 0.00 | 0.00 |
| December | 0.265228E+09 | 54852107.31 | 0.108878E+09 | 0.00 | 0.108878E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.436227E+10 | 0.247356E+09 | 0.163917E+10 | 87245866.33 | 0.155193E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.265228E+09 | 3498860.21 | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.562131E+09 | 54852107.31 | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.276716E+09 | 46218435.93 | 0.112074E+09 | 0.00 | 0.112074E+09 | 0.00 | 0.00 |
| February | 0.282390E+09 | 28117436.96 | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.00 | 0.00 |
| March | 0.343902E+09 | 16245169.16 | 0.122797E+09 | 21683.77 | 0.122775E+09 | 0.00 | 0.00 |
| April | 0.387497E+09 | 3496072.37 | 0.130886E+09 | 2466740.50 | 0.128420E+09 | 0.00 | 0.00 |
| May | 0.500020E+09 | 6950861.32 | 0.171666E+09 | 18735234.68 | 0.152931E+09 | 0.00 | 0.00 |
| June | 0.562117E+09 | 7402888.70 | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.00 | 0.00 |
| July | 0.454196E+09 | 17327033.50 | 0.179198E+09 | 18240175.10 | 0.160958E+09 | 0.00 | 0.00 |
| August | 0.382996E+09 | 12176071.96 | 0.149152E+09 | 7326383.82 | 0.141826E+09 | 0.00 | 0.00 |
| September | 0.329565E+09 | 11470828.20 | 0.122176E+09 | 168559.27 | 0.122007E+09 | 0.00 | 0.00 |
| October | 0.301071E+09 | 17079668.16 | 0.121434E+09 | 0.00 | 0.121434E+09 | 0.00 | 0.00 |
| November | 0.276360E+09 | 25958754.14 | 0.111197E+09 | 0.00 | 0.111197E+09 | 0.00 | 0.00 |
| December | 0.265191E+09 | 54844571.11 | 0.108878E+09 | 0.00 | 0.108878E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.436202E+10 | 0.247288E+09 | 0.163917E+10 | 87245866.33 | 0.155193E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.265191E+09 | 3496072.37 | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.562117E+09 | 54844571.11 | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.662146E+09 | 44817087.98 | 0.294108E+09 | 0.121162E+09 | 0.172946E+09 | 0.00 | 0.00 |
| February | 0.558262E+09 | 26945858.53 | 0.229638E+09 | 76259171.80 | 0.153379E+09 | 0.00 | 0.00 |
| March | 0.472753E+09 | 14698879.86 | 0.172569E+09 | 23772949.97 | 0.148796E+09 | 0.00 | 0.00 |
| April | 0.381692E+09 | 3437905.85 | 0.125658E+09 | 1329232.19 | 0.124329E+09 | 0.00 | 0.00 |
| May | 0.399368E+09 | 6480646.93 | 0.128288E+09 | 0.00 | 0.128288E+09 | 0.00 | 0.00 |
| June | 0.381282E+09 | 6932388.78 | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.00 | 0.00 |
| July | 0.344059E+09 | 16337109.42 | 0.131680E+09 | 0.00 | 0.131680E+09 | 0.00 | 0.00 |
| August | 0.334816E+09 | 11047650.75 | 0.128072E+09 | 78684.75 | 0.127993E+09 | 0.00 | 0.00 |
| September | 0.364776E+09 | 11540236.16 | 0.136697E+09 | 3766062.87 | 0.132931E+09 | 0.00 | 0.00 |
| October | 0.442545E+09 | 18146317.10 | 0.184496E+09 | 28412967.82 | 0.156083E+09 | 0.00 | 0.00 |
| November | 0.543258E+09 | 27344579.00 | 0.236031E+09 | 73614914.47 | 0.162416E+09 | 0.00 | 0.00 |
| December | 0.653143E+09 | 54986999.78 | 0.295679E+09 | 0.125273E+09 | 0.170406E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.553810E+10 | 0.242716E+09 | 0.218662E+10 | 0.453669E+09 | 0.173295E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.334816E+09 | 3437905.85 | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.662146E+09 | 54986999.78 | 0.295679E+09 | 0.125273E+09 | 0.172946E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.662113E+09 | 44807779.22 | 0.294108E+09 | 0.121162E+09 | 0.172946E+09 | 0.00 | 0.00 |
| February | 0.558234E+09 | 26938066.47 | 0.229638E+09 | 76259171.80 | 0.153379E+09 | 0.00 | 0.00 |
| March | 0.472748E+09 | 14685092.22 | 0.172569E+09 | 23772949.97 | 0.148796E+09 | 0.00 | 0.00 |
| April | 0.381686E+09 | 3435373.47 | 0.125658E+09 | 1329232.19 | 0.124329E+09 | 0.00 | 0.00 |
| May | 0.399355E+09 | 6476771.52 | 0.128288E+09 | 0.00 | 0.128288E+09 | 0.00 | 0.00 |
| June | 0.381267E+09 | 6930250.65 | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.00 | 0.00 |
| July | 0.344044E+09 | 16329719.48 | 0.131680E+09 | 0.00 | 0.131680E+09 | 0.00 | 0.00 |
| August | 0.334795E+09 | 11042958.92 | 0.128072E+09 | 78684.75 | 0.127993E+09 | 0.00 | 0.00 |
| September | 0.364759E+09 | 11537379.93 | 0.136697E+09 | 3766062.87 | 0.132931E+09 | 0.00 | 0.00 |
| October | 0.442534E+09 | 18139740.61 | 0.184496E+09 | 28412967.82 | 0.156083E+09 | 0.00 | 0.00 |
| November | 0.543242E+09 | 27339785.48 | 0.236031E+09 | 73614914.47 | 0.162416E+09 | 0.00 | 0.00 |
| December | 0.653113E+09 | 54977762.89 | 0.295679E+09 | 0.125273E+09 | 0.170406E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.553789E+10 | 0.242641E+09 | 0.218662E+10 | 0.453669E+09 | 0.173295E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.334795E+09 | 3435373.47 | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.662113E+09 | 54977762.89 | 0.295679E+09 | 0.125273E+09 | 0.172946E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.958185E+09 | 75228756.60 | 0.438547E+09 | 0.172170E+09 | 0.266378E+09 | 0.00 | 0.00 |
| February | 0.861118E+09 | 45307182.05 | 0.372558E+09 | 0.126843E+09 | 0.245715E+09 | 0.00 | 0.00 |
| March | 0.861715E+09 | 26900080.65 | 0.350034E+09 | 93934357.27 | 0.256100E+09 | 0.00 | 0.00 |
| April | 0.772476E+09 | 5996346.07 | 0.297920E+09 | 67174140.34 | 0.230746E+09 | 0.00 | 0.00 |
| May | 0.761272E+09 | 11858010.35 | 0.279927E+09 | 44914133.92 | 0.235013E+09 | 0.00 | 0.00 |
| June | 0.752563E+09 | 12781150.76 | 0.282649E+09 | 54734314.60 | 0.227914E+09 | 0.00 | 0.00 |
| July | 0.650934E+09 | 29401429.43 | 0.271855E+09 | 33089957.42 | 0.238765E+09 | 0.00 | 0.00 |
| August | 0.660384E+09 | 19630873.18 | 0.280553E+09 | 45290254.48 | 0.235263E+09 | 0.00 | 0.00 |
| September | 0.667845E+09 | 20947002.32 | 0.274647E+09 | 41936740.99 | 0.232711E+09 | 0.00 | 0.00 |
| October | 0.720917E+09 | 31952104.22 | 0.318498E+09 | 62939955.70 | 0.255558E+09 | 0.00 | 0.00 |
| November | 0.804127E+09 | 45757484.78 | 0.362313E+09 | 0.107930E+09 | 0.254383E+09 | 0.00 | 0.00 |
| December | 0.926040E+09 | 90941923.06 | 0.429487E+09 | 0.169094E+09 | 0.260393E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.939758E+10 | 0.416702E+09 | 0.395899E+10 | 0.102005E+10 | 0.293894E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.650934E+09 | 5996346.07 | 0.271855E+09 | 33089957.42 | 0.227914E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.958185E+09 | 90941923.06 | 0.438547E+09 | 0.172170E+09 | 0.266378E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.581517E+09 | 77100583.75 | 0.256513E+09 | 51007891.94 | 0.205505E+09 | 0.00 | 0.00 |
| February | 0.591945E+09 | 47122577.42 | 0.250902E+09 | 50583646.60 | 0.200318E+09 | 0.00 | 0.00 |
| March | 0.736221E+09 | 28769268.71 | 0.300262E+09 | 70183091.07 | 0.230079E+09 | 0.00 | 0.00 |
| April | 0.778019E+09 | 6117691.68 | 0.303149E+09 | 68311648.65 | 0.234837E+09 | 0.00 | 0.00 |
| May | 0.859512E+09 | 12394528.62 | 0.323305E+09 | 63649368.60 | 0.259656E+09 | 0.00 | 0.00 |
| June | 0.929332E+09 | 13275326.19 | 0.360678E+09 | 95021403.79 | 0.265656E+09 | 0.00 | 0.00 |
| July | 0.758339E+09 | 30483055.85 | 0.319373E+09 | 51330132.52 | 0.268043E+09 | 0.00 | 0.00 |
| August | 0.707524E+09 | 20845910.77 | 0.301633E+09 | 52537953.55 | 0.249096E+09 | 0.00 | 0.00 |
| September | 0.633643E+09 | 20887213.52 | 0.260126E+09 | 38339237.38 | 0.221787E+09 | 0.00 | 0.00 |
| October | 0.582710E+09 | 30803725.08 | 0.255437E+09 | 34526987.88 | 0.220910E+09 | 0.00 | 0.00 |
| November | 0.543136E+09 | 44397928.41 | 0.237479E+09 | 34315245.16 | 0.203164E+09 | 0.00 | 0.00 |
| December | 0.547001E+09 | 91010863.11 | 0.242686E+09 | 43820569.77 | 0.198865E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.824890E+10 | 0.423209E+09 | 0.341154E+10 | 0.653627E+09 | 0.275792E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.543136E+09 | 6117691.68 | 0.237479E+09 | 34315245.16 | 0.198865E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.929332E+09 | 91010863.11 | 0.360678E+09 | 95021403.79 | 0.268043E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.950110E+09 | 72740528.21 | 0.436618E+09 | 0.169411E+09 | 0.267208E+09 | 0.00 | 0.00 |
| February | 0.863138E+09 | 43258849.96 | 0.374861E+09 | 0.129257E+09 | 0.245604E+09 | 0.00 | 0.00 |
| March | 0.857681E+09 | 24079434.20 | 0.348444E+09 | 92517078.72 | 0.255927E+09 | 0.00 | 0.00 |
| April | 0.776468E+09 | 5796706.09 | 0.297591E+09 | 67038174.01 | 0.230553E+09 | 0.00 | 0.00 |
| May | 0.765931E+09 | 11799895.73 | 0.280929E+09 | 46161163.88 | 0.234768E+09 | 0.00 | 0.00 |
| June | 0.750799E+09 | 12466200.70 | 0.281144E+09 | 51884356.97 | 0.229260E+09 | 0.00 | 0.00 |
| July | 0.648698E+09 | 29006059.76 | 0.270692E+09 | 31214610.43 | 0.239477E+09 | 0.00 | 0.00 |
| August | 0.662779E+09 | 19660503.27 | 0.280884E+09 | 44946287.12 | 0.235938E+09 | 0.00 | 0.00 |
| September | 0.672091E+09 | 20602801.59 | 0.275730E+09 | 41710993.80 | 0.234019E+09 | 0.00 | 0.00 |
| October | 0.723462E+09 | 31413200.42 | 0.319277E+09 | 63016149.02 | 0.256261E+09 | 0.00 | 0.00 |
| November | 0.803986E+09 | 45190555.45 | 0.362371E+09 | 0.108641E+09 | 0.253730E+09 | 0.00 | 0.00 |
| December | 0.920902E+09 | 89127851.35 | 0.429024E+09 | 0.168102E+09 | 0.260923E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.939605E+10 | 0.405143E+09 | 0.395757E+10 | 0.101390E+10 | 0.294367E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.648698E+09 | 5796706.09 | 0.270692E+09 | 31214610.43 | 0.229260E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.950110E+09 | 89127851.35 | 0.436618E+09 | 0.169411E+09 | 0.267208E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.569436E+09 | 71053220.18 | 0.254584E+09 | 48248987.90 | 0.206335E+09 | 0.00 | 0.00 |
| February | 0.591733E+09 | 43054372.16 | 0.253205E+09 | 52997774.44 | 0.200207E+09 | 0.00 | 0.00 |
| March | 0.731852E+09 | 25607299.48 | 0.298672E+09 | 68765812.51 | 0.229906E+09 | 0.00 | 0.00 |
| April | 0.781893E+09 | 5875242.62 | 0.302820E+09 | 68175682.32 | 0.234644E+09 | 0.00 | 0.00 |
| May | 0.864236E+09 | 12406324.53 | 0.324308E+09 | 64896398.56 | 0.259411E+09 | 0.00 | 0.00 |
| June | 0.927877E+09 | 13185030.39 | 0.359173E+09 | 92171446.16 | 0.267001E+09 | 0.00 | 0.00 |
| July | 0.756314E+09 | 30325986.38 | 0.318210E+09 | 49454785.53 | 0.268755E+09 | 0.00 | 0.00 |
| August | 0.710193E+09 | 21067485.66 | 0.301965E+09 | 52193986.19 | 0.249771E+09 | 0.00 | 0.00 |
| September | 0.637901E+09 | 20587930.25 | 0.261209E+09 | 38113490.19 | 0.223095E+09 | 0.00 | 0.00 |
| October | 0.585081E+09 | 30105131.78 | 0.256216E+09 | 34603181.21 | 0.221612E+09 | 0.00 | 0.00 |
| November | 0.542117E+09 | 43029793.18 | 0.237537E+09 | 35025750.75 | 0.202511E+09 | 0.00 | 0.00 |
| December | 0.538335E+09 | 85933711.63 | 0.242223E+09 | 42828667.37 | 0.199395E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.823697E+10 | 0.402232E+09 | 0.341012E+10 | 0.647476E+09 | 0.276264E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.538335E+09 | 5875242.62 | 0.237537E+09 | 34603181.21 | 0.199395E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.927877E+09 | 85933711.63 | 0.359173E+09 | 92171446.16 | 0.268755E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.268990E+09 | 45724283.13 | 0.112074E+09 | 0.00 | 0.112074E+09 | 0.00 | 0.00 |
| February | 0.274707E+09 | 27711311.10 | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.00 | 0.00 |
| March | 0.334379E+09 | 16348970.30 | 0.122797E+09 | 21683.77 | 0.122775E+09 | 0.00 | 0.00 |
| April | 0.376677E+09 | 3508803.82 | 0.130886E+09 | 2466740.50 | 0.128420E+09 | 0.00 | 0.00 |
| May | 0.488617E+09 | 7253107.86 | 0.171666E+09 | 18735234.68 | 0.152931E+09 | 0.00 | 0.00 |
| June | 0.550438E+09 | 7729009.49 | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.00 | 0.00 |
| July | 0.444019E+09 | 17825719.91 | 0.179198E+09 | 18240175.10 | 0.160958E+09 | 0.00 | 0.00 |
| August | 0.373562E+09 | 12482273.08 | 0.149152E+09 | 7326383.82 | 0.141826E+09 | 0.00 | 0.00 |
| September | 0.320480E+09 | 12125574.72 | 0.122176E+09 | 168559.27 | 0.122007E+09 | 0.00 | 0.00 |
| October | 0.292967E+09 | 17858145.62 | 0.121434E+09 | 0.00 | 0.121434E+09 | 0.00 | 0.00 |
| November | 0.268785E+09 | 26199989.01 | 0.111197E+09 | 0.00 | 0.111197E+09 | 0.00 | 0.00 |
| December | 0.258081E+09 | 54298640.74 | 0.108878E+09 | 0.00 | 0.108878E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.425170E+10 | 0.249066E+09 | 0.163917E+10 | 87245866.33 | 0.155193E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.258081E+09 | 3508803.82 | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.550438E+09 | 54298640.74 | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.268880E+09 | 45693019.57 | 0.112074E+09 | 0.00 | 0.112074E+09 | 0.00 | 0.00 |
| February | 0.274631E+09 | 27686411.17 | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.00 | 0.00 |
| March | 0.334360E+09 | 16317539.01 | 0.122797E+09 | 21683.77 | 0.122775E+09 | 0.00 | 0.00 |
| April | 0.376669E+09 | 3503218.36 | 0.130886E+09 | 2466740.50 | 0.128420E+09 | 0.00 | 0.00 |
| May | 0.488598E+09 | 7245008.97 | 0.171666E+09 | 18735234.68 | 0.152931E+09 | 0.00 | 0.00 |
| June | 0.550412E+09 | 7719591.19 | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.00 | 0.00 |
| July | 0.443987E+09 | 17805975.55 | 0.179198E+09 | 18240175.10 | 0.160958E+09 | 0.00 | 0.00 |
| August | 0.373524E+09 | 12466553.85 | 0.149152E+09 | 7326383.82 | 0.141826E+09 | 0.00 | 0.00 |
| September | 0.320449E+09 | 12112698.95 | 0.122176E+09 | 168559.27 | 0.122007E+09 | 0.00 | 0.00 |
| October | 0.292940E+09 | 17839859.96 | 0.121434E+09 | 0.00 | 0.121434E+09 | 0.00 | 0.00 |
| November | 0.268749E+09 | 26181161.50 | 0.111197E+09 | 0.00 | 0.111197E+09 | 0.00 | 0.00 |
| December | 0.257997E+09 | 54266914.99 | 0.108878E+09 | 0.00 | 0.108878E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.425120E+10 | 0.248838E+09 | 0.163917E+10 | 87245866.33 | 0.155193E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.257997E+09 | 3503218.36 | 0.107982E+09 | 0.00 | 0.107982E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.550412E+09 | 54266914.99 | 0.201731E+09 | 40287089.19 | 0.161444E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.651801E+09 | 43906460.09 | 0.294108E+09 | 0.121162E+09 | 0.172946E+09 | 0.00 | 0.00 |
| February | 0.548597E+09 | 26033204.16 | 0.229638E+09 | 76259171.80 | 0.153379E+09 | 0.00 | 0.00 |
| March | 0.462212E+09 | 14401855.27 | 0.172569E+09 | 23772949.97 | 0.148796E+09 | 0.00 | 0.00 |
| April | 0.371185E+09 | 3440806.47 | 0.125658E+09 | 1329232.19 | 0.124329E+09 | 0.00 | 0.00 |
| May | 0.388861E+09 | 6835110.15 | 0.128288E+09 | 0.00 | 0.128288E+09 | 0.00 | 0.00 |
| June | 0.370856E+09 | 7347390.25 | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.00 | 0.00 |
| July | 0.334880E+09 | 16933908.95 | 0.131680E+09 | 0.00 | 0.131680E+09 | 0.00 | 0.00 |
| August | 0.325634E+09 | 11339652.98 | 0.128072E+09 | 78684.75 | 0.127993E+09 | 0.00 | 0.00 |
| September | 0.355304E+09 | 12156388.54 | 0.136697E+09 | 3766062.87 | 0.132931E+09 | 0.00 | 0.00 |
| October | 0.433242E+09 | 18750272.49 | 0.184496E+09 | 28412967.82 | 0.156083E+09 | 0.00 | 0.00 |
| November | 0.533792E+09 | 27250521.35 | 0.236031E+09 | 73614914.47 | 0.162416E+09 | 0.00 | 0.00 |
| December | 0.643429E+09 | 54137395.32 | 0.295679E+09 | 0.125273E+09 | 0.170406E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.541979E+10 | 0.242533E+09 | 0.218662E+10 | 0.453669E+09 | 0.173295E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.325634E+09 | 3440806.47 | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.651801E+09 | 54137395.32 | 0.295679E+09 | 0.125273E+09 | 0.172946E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.651725E+09 | 43873417.89 | 0.294108E+09 | 0.121162E+09 | 0.172946E+09 | 0.00 | 0.00 |
| February | 0.548539E+09 | 26009324.82 | 0.229638E+09 | 76259171.80 | 0.153379E+09 | 0.00 | 0.00 |
| March | 0.462199E+09 | 14372474.83 | 0.172569E+09 | 23772949.97 | 0.148796E+09 | 0.00 | 0.00 |
| April | 0.371180E+09 | 3435976.03 | 0.125658E+09 | 1329232.19 | 0.124329E+09 | 0.00 | 0.00 |
| May | 0.388841E+09 | 6827403.39 | 0.128288E+09 | 0.00 | 0.128288E+09 | 0.00 | 0.00 |
| June | 0.370829E+09 | 7337985.62 | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.00 | 0.00 |
| July | 0.334849E+09 | 16913379.15 | 0.131680E+09 | 0.00 | 0.131680E+09 | 0.00 | 0.00 |
| August | 0.325595E+09 | 11324221.77 | 0.128072E+09 | 78684.75 | 0.127993E+09 | 0.00 | 0.00 |
| September | 0.355274E+09 | 12142842.88 | 0.136697E+09 | 3766062.87 | 0.132931E+09 | 0.00 | 0.00 |
| October | 0.433217E+09 | 18731659.08 | 0.184496E+09 | 28412967.82 | 0.156083E+09 | 0.00 | 0.00 |
| November | 0.533760E+09 | 27232676.05 | 0.236031E+09 | 73614914.47 | 0.162416E+09 | 0.00 | 0.00 |
| December | 0.643363E+09 | 54105625.40 | 0.295679E+09 | 0.125273E+09 | 0.170406E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.541937E+10 | 0.242307E+09 | 0.218662E+10 | 0.453669E+09 | 0.173295E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.325595E+09 | 3435976.03 | 0.123702E+09 | 0.00 | 0.123702E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.651725E+09 | 54105625.40 | 0.295679E+09 | 0.125273E+09 | 0.172946E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 69110939.29 | 11059028.01 | 34196062.32 | 11577541.04 | 22618521.28 | 0.00 | 0.00 |
| February | 73046369.90 | 7547492.01 | 34846737.02 | 12717031.70 | 22129705.32 | 0.00 | 0.00 |
| March | 90866946.19 | 5686861.32 | 42201909.13 | 16495433.51 | 25706475.63 | 0.00 | 0.00 |
| April | 91306983.77 | 2142237.51 | 41256065.79 | 15767128.05 | 25488937.74 | 0.00 | 0.00 |
| May | 84293392.34 | 3313454.32 | 36626963.32 | 11076559.17 | 25550404.15 | 0.00 | 0.00 |
| June | 85493859.97 | 3490826.67 | 37778802.05 | 12449862.65 | 25328939.41 | 0.00 | 0.00 |
| July | 70898363.25 | 6401581.80 | 33356445.68 | 7490072.83 | 25866372.85 | 0.00 | 0.00 |
| August | 76609321.16 | 5496536.63 | 36667957.47 | 10766163.82 | 25901793.65 | 0.00 | 0.00 |
| September | 71781427.61 | 5200915.32 | 33361452.95 | 9105040.63 | 24256412.32 | 0.00 | 0.00 |
| October | 65721269.74 | 6967667.17 | 32341302.13 | 8303174.18 | 24038127.95 | 0.00 | 0.00 |
| November | 61656499.46 | 8053896.90 | 30315806.25 | 8404571.46 | 21911234.78 | 0.00 | 0.00 |
| December | 64309386.06 | 12807923.85 | 31996775.08 | 10276913.06 | 21719862.01 | 0.00 | 0.00 |
| Annual Sum or Average | 0.905095E+09 | 78168421.50 | 0.424946E+09 | 0.134429E+09 | 0.290517E+09 | 0.00 | 0.00 |
| Minimum of Months | 61656499.46 | 2142237.51 | 30315806.25 | 7490072.83 | 21719862.01 | 0.00 | 0.00 |
| Maximum of Months | 91306983.77 | 12807923.85 | 42201909.13 | 16495433.51 | 25901793.65 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.197204E+09 | 44622256.05 | 0.101844E+09 | 34480798.44 | 67363585.30 | 0.00 | 0.00 |
| February | 0.208134E+09 | 33733048.97 | 0.103782E+09 | 37874485.21 | 65907769.73 | 0.00 | 0.00 |
| March | 0.259023E+09 | 29284461.18 | 0.125688E+09 | 49127506.10 | 76560281.81 | 0.00 | 0.00 |
| April | 0.258168E+09 | 16205879.85 | 0.122871E+09 | 46958431.20 | 75912399.85 | 0.00 | 0.00 |
| May | 0.235098E+09 | 18502434.92 | 0.109084E+09 | 32988749.75 | 76095462.12 | 0.00 | 0.00 |
| June | 0.240781E+09 | 19663819.94 | 0.112515E+09 | 37078789.27 | 75435885.00 | 0.00 | 0.00 |
| July | 0.200206E+09 | 28778007.83 | 99343796.42 | 22307300.89 | 77036495.53 | 0.00 | 0.00 |
| August | 0.216662E+09 | 26684016.29 | 0.109206E+09 | 32064315.15 | 77141987.50 | 0.00 | 0.00 |
| September | 0.202970E+09 | 24962578.17 | 99358709.32 | 27117076.90 | 72241632.42 | 0.00 | 0.00 |
| October | 0.186126E+09 | 31175580.51 | 96320446.31 | 24728919.06 | 71591527.25 | 0.00 | 0.00 |
| November | 0.175126E+09 | 34316863.51 | 90288015.50 | 25030905.40 | 65257110.09 | 0.00 | 0.00 |
| December | 0.183371E+09 | 49421992.24 | 95294359.01 | 30607204.65 | 64687154.36 | 0.00 | 0.00 |
| Annual Sum or Average | 0.256287E+10 | 0.357351E+09 | 0.126560E+10 | 0.400364E+09 | 0.865231E+09 | 0.00 | 0.00 |
| Minimum of Months | 0.175126E+09 | 16205879.85 | 90288015.50 | 22307300.89 | 64687154.36 | 0.00 | 0.00 |
| Maximum of Months | 0.259023E+09 | 49421992.24 | 0.125688E+09 | 49127506.10 | 77141987.50 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 70316659.12 | 11018759.84 | 34196062.32 | 11577541.04 | 22618521.28 | 0.00 | 0.00 |
| February | 74360934.51 | 7568321.03 | 34846737.02 | 12717031.70 | 22129705.32 | 0.00 | 0.00 |
| March | 92668973.41 | 5526409.36 | 42201909.13 | 16495433.51 | 25706475.63 | 0.00 | 0.00 |
| April | 93602647.33 | 2094699.26 | 41256065.79 | 15767128.05 | 25488937.74 | 0.00 | 0.00 |
| May | 86597515.22 | 3104114.19 | 36626963.32 | 11076559.17 | 25550404.15 | 0.00 | 0.00 |
| June | 87703701.55 | 3240106.27 | 37778802.05 | 12449862.65 | 25328939.41 | 0.00 | 0.00 |
| July | 72542714.38 | 6099904.73 | 33356445.68 | 7490072.83 | 25866372.85 | 0.00 | 0.00 |
| August | 78152487.12 | 5174716.08 | 36667957.47 | 10766163.82 | 25901793.65 | 0.00 | 0.00 |
| September | 73437779.79 | 4873401.68 | 33361452.95 | 9105040.63 | 24256412.32 | 0.00 | 0.00 |
| October | 67136821.65 | 6638614.07 | 32341302.13 | 8303174.18 | 24038127.95 | 0.00 | 0.00 |
| November | 62937541.77 | 7860578.49 | 30315806.25 | 8404571.46 | 21911234.78 | 0.00 | 0.00 |
| December | 65360130.54 | 12773575.71 | 31996775.08 | 10276913.06 | 21719862.01 | 0.00 | 0.00 |
| Annual Sum or Average | 0.924818E+09 | 75973200.71 | 0.424946E+09 | 0.134429E+09 | 0.290517E+09 | 0.00 | 0.00 |
| Minimum of Months | 62937541.77 | 2094699.26 | 30315806.25 | 7490072.83 | 21719862.01 | 0.00 | 0.00 |
| Maximum of Months | 93602647.33 | 12773575.71 | 42201909.13 | 16495433.51 | 25901793.65 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
| January | 26.42 | 22.38 | 20.70 | 2.25 | 18.66 | 103.85 | 146.57 | 0.01 |
| February | 27.50 | 22.91 | 21.01 | 2.37 | 18.54 | 110.59 | 164.59 | 0.00 |
| March | 28.33 | 23.63 | 21.77 | 3.67 | 19.85 | 110.33 | 194.39 | 0.01 |
| April | 29.15 | 25.37 | 24.04 | 2.98 | 21.51 | 118.69 | 185.56 | 0.03 |
| May | 29.01 | 26.53 | 25.72 | 3.19 | 23.00 | 127.71 | 124.87 | 0.08 |
| June | 28.86 | 26.50 | 25.74 | 3.10 | 22.78 | 123.38 | 156.09 | 0.05 |
| July | 27.25 | 24.29 | 23.20 | 2.32 | 21.53 | 137.39 | 88.28 | 0.02 |
| August | 27.54 | 25.86 | 25.31 | 3.22 | 21.55 | 129.55 | 122.00 | 0.07 |
| September | 27.58 | 25.59 | 24.93 | 2.22 | 22.01 | 128.30 | 103.37 | 0.04 |
| October | 26.89 | 25.07 | 24.46 | 2.18 | 21.39 | 123.79 | 92.41 | 0.11 |
| November | 26.68 | 24.14 | 23.20 | 1.94 | 20.29 | 113.70 | 103.30 | 0.02 |
| December | 25.97 | 22.85 | 21.57 | 2.00 | 18.63 | 101.83 | 131.96 | 0.00 |
| Annual Sum or Average | 27.59 | 24.60 | 23.48 | 2.62 | 20.82 | 119.14 | 134.17 | 0.04 |
| Minimum of Months | 25.97 | 22.38 | 20.70 | 1.94 | 18.54 | 101.83 | 88.28 | 0.00 |
| Maximum of Months | 29.15 | 26.53 | 25.74 | 3.67 | 23.00 | 137.39 | 194.39 | 0.11 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 34.10 | 04-JAN-12:00 | 23.67 | 19.40 | 5.00 | 24.66 | 266.50 | 576.50 |
| February | 35.00 | 21-FEB-13:00 | 22.02 | 16.00 | 2.10 | 24.16 | 230.00 | 672.50 |
| March | 36.40 | 21-MAR-12:00 | 23.01 | 17.00 | 5.00 | 26.97 | 269.50 | 658.50 |
| April | 35.50 | 01-APR-13:00 | 26.96 | 24.00 | 2.50 | 27.14 | 295.50 | 519.50 |
| May | 37.60 | 06-MAY-12:00 | 26.43 | 22.60 | 4.00 | 29.39 | 317.00 | 525.50 |
| June | 36.00 | 12-JUN-14:00 | 27.60 | 25.00 | 4.00 | 28.43 | 235.00 | 472.00 |
| July | 33.20 | 15-JUL-15:00 | 25.63 | 23.00 | 2.00 | 27.95 | 219.00 | 181.00 |
| August | 34.00 | 10-AUG-13:00 | 27.86 | 26.00 | 5.00 | 26.65 | 344.50 | 278.50 |
| September | 34.00 | 06-SEP-13:00 | 26.51 | 24.00 | 4.00 | 25.00 | 258.00 | 581.50 |
| October | 33.00 | 04-OCT-13:00 | 26.23 | 24.00 | 4.00 | 25.16 | 303.00 | 428.50 |
| November | 34.30 | 18-NOV-12:00 | 25.34 | 22.20 | 3.00 | 25.49 | 289.50 | 511.50 |
| December | 33.00 | 07-DEC-13:00 | 23.23 | 19.00 | 3.00 | 22.98 | 215.00 | 596.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 33.00 | 22.02 | 16.00 | 2.00 | 22.98 | 215.00 | 181.00 | |
| Maximum of Months | 37.60 | 27.86 | 26.00 | 5.00 | 29.39 | 344.50 | 672.50 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 18.70 | 23-JAN-05:00 | 16.92 | 16.00 | 2.00 | 7.75 | 0.00 | 0.00 |
| February | 20.30 | 21-FEB-09:00 | 19.04 | 18.40 | 2.00 | 10.50 | 258.50 | 564.00 |
| March | 22.00 | 03-MAR-05:00 | 19.94 | 19.00 | 3.00 | 13.35 | 0.00 | 0.00 |
| April | 22.90 | 14-APR-15:00 | 22.90 | 22.90 | 3.00 | 14.65 | 199.50 | 264.50 |
| May | 22.00 | 10-MAY-19:00 | 22.00 | 22.00 | 2.00 | 18.28 | 0.00 | 0.00 |
| June | 23.00 | 20-JUN-23:00 | 23.00 | 23.00 | 2.00 | 19.35 | 0.00 | 0.00 |
| July | 23.00 | 13-JUL-04:00 | 22.27 | 22.00 | 0.00 | 13.91 | 0.00 | 0.00 |
| August | 22.00 | 20-AUG-10:00 | 22.00 | 22.00 | 5.00 | 18.28 | 430.50 | 41.50 |
| September | 22.90 | 19-SEP-03:00 | 22.78 | 22.78 | 0.00 | 21.27 | 0.00 | 0.00 |
| October | 22.50 | 23-OCT-04:00 | 22.50 | 22.50 | 2.80 | 18.82 | 0.00 | 0.00 |
| November | 20.00 | 25-NOV-04:00 | 18.63 | 18.00 | 2.00 | 10.69 | 0.00 | 0.00 |
| December | 18.00 | 21-DEC-04:00 | 17.36 | 17.00 | 3.00 | 9.13 | 0.00 | 0.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 18.00 | 16.92 | 16.00 | 0.00 | 7.75 | 0.00 | 0.00 | |
| Maximum of Months | 23.00 | 23.00 | 23.00 | 5.00 | 21.27 | 430.50 | 564.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 25.53 | 12-JAN-12:00 | 32.40 | 23.10 | 2.00 | 25.00 | 353.00 | 347.00 |
| February | 26.17 | 14-FEB-15:00 | 32.30 | 24.20 | 2.00 | 25.16 | 200.00 | 199.00 |
| March | 26.28 | 27-MAR-12:00 | 34.20 | 23.60 | 4.00 | 26.32 | 326.00 | 535.00 |
| April | 27.93 | 10-APR-16:49 | 31.52 | 26.85 | 4.08 | 27.70 | 110.67 | 57.00 |
| May | 29.00 | 28-MAY-20:00 | 29.00 | 29.00 | 3.00 | 22.47 | 0.00 | 0.00 |
| June | 30.11 | 15-JUN-09:00 | 33.20 | 29.20 | 5.00 | 26.48 | 320.50 | 421.00 |
| July | 26.43 | 20-JUL-14:00 | 32.80 | 24.20 | 1.00 | 26.65 | 305.00 | 253.00 |
| August | 28.81 | 14-AUG-16:00 | 32.00 | 28.00 | 1.00 | 25.16 | 107.50 | 223.00 |
| September | 30.06 | 30-SEP-10:00 | 32.80 | 29.40 | 3.00 | 25.66 | 398.00 | 359.50 |
| October | 27.36 | 16-OCT-14:00 | 31.50 | 26.00 | 3.00 | 24.16 | 239.00 | 346.50 |
| November | 27.56 | 10-NOV-12:00 | 31.00 | 26.40 | 6.00 | 28.11 | 388.00 | 95.50 |
| December | 26.86 | 03-DEC-12:00 | 31.50 | 25.30 | 1.00 | 23.49 | 301.00 | 468.50 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 25.53 | 29.00 | 23.10 | 1.00 | 22.47 | 0.00 | 0.00 | |
| Maximum of Months | 30.11 | 34.20 | 29.40 | 6.00 | 28.11 | 398.00 | 535.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 24.20 | 09-JAN-21:00 | 26.50 | 24.77 | 4.00 | 25.16 | 0.00 | 0.00 |
| February | 24.40 | 15-FEB-18:00 | 28.30 | 25.33 | 4.00 | 20.75 | 0.00 | 0.00 |
| March | 25.30 | 28-MAR-06:00 | 27.20 | 25.72 | 3.00 | 19.87 | 103.00 | 28.00 |
| April | 27.00 | 10-APR-17:00 | 30.50 | 27.87 | 4.50 | 25.00 | 20.00 | 20.50 |
| May | 29.00 | 28-MAY-20:00 | 29.00 | 29.00 | 3.00 | 22.47 | 0.00 | 0.00 |
| June | 29.20 | 15-JUN-09:00 | 33.20 | 30.11 | 5.00 | 26.48 | 320.50 | 421.00 |
| July | 26.00 | 10-JUL-14:00 | 26.50 | 26.11 | 2.30 | 23.49 | 286.00 | 36.50 |
| August | 28.00 | 02-AUG-10:00 | 31.00 | 28.65 | 4.00 | 24.16 | 419.00 | 195.50 |
| September | 29.40 | 30-SEP-10:00 | 32.80 | 30.06 | 3.00 | 25.66 | 398.00 | 359.50 |
| October | 26.50 | 16-OCT-08:00 | 29.00 | 27.04 | 2.50 | 21.78 | 300.00 | 326.00 |
| November | 26.40 | 10-NOV-12:00 | 31.00 | 27.56 | 6.00 | 28.11 | 388.00 | 95.50 |
| December | 26.00 | 10-DEC-17:00 | 29.00 | 26.74 | 3.00 | 21.78 | 0.00 | 0.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 24.20 | 26.50 | 24.77 | 2.30 | 19.87 | 0.00 | 0.00 | |
| Maximum of Months | 29.40 | 33.20 | 30.11 | 6.00 | 28.11 | 419.00 | 421.00 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
| January | 18.00 | 13.00 | 16.00 | 29.71 | 38.82 | 0.00 |
| February | 18.00 | 13.00 | 16.00 | 29.90 | 44.34 | 0.00 |
| March | 18.00 | 13.00 | 16.00 | 30.35 | 50.49 | 0.00 |
| April | 18.00 | 13.00 | 16.00 | 30.97 | 51.18 | 0.00 |
| May | 18.00 | 13.00 | 16.00 | 31.58 | 43.47 | 0.00 |
| June | 18.00 | 13.00 | 16.00 | 32.02 | 46.77 | 0.00 |
| July | 18.00 | 13.00 | 16.00 | 32.16 | 39.95 | 0.00 |
| August | 18.00 | 13.00 | 16.00 | 31.97 | 43.65 | 0.00 |
| September | 18.00 | 13.00 | 16.00 | 31.50 | 40.53 | 0.00 |
| October | 18.00 | 13.00 | 16.00 | 30.87 | 37.35 | 0.00 |
| November | 18.00 | 13.00 | 16.00 | 30.27 | 35.77 | 0.00 |
| December | 18.00 | 13.00 | 16.00 | 29.84 | 36.19 | 0.00 |
| Annual Sum or Average | 18.00 | 13.00 | 16.00 | 30.93 | 42.35 | 0.00 |
| Minimum of Months | 18.00 | 13.00 | 16.00 | 29.71 | 35.77 | 0.00 |
| Maximum of Months | 18.00 | 13.00 | 16.00 | 32.16 | 51.18 | 0.00 |
Report: WaterHeaterReportMonthly
For: SWHSYS1 WATER HEATER
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.210116E+11 | -0.201485E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -863080313.3 | 59.95 | 0.00 | 0.00 |
| February | 0.188585E+11 | -0.180842E+11 | 0.00 | 0.00 | 672.00 | 0.00 | -774343990.9 | 59.95 | 0.00 | 0.00 |
| March | 0.205731E+11 | -0.197184E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -854687323.7 | 59.95 | 0.00 | 0.00 |
| April | 0.195053E+11 | -0.186818E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -823449201.0 | 59.95 | 0.00 | 0.00 |
| May | 0.197485E+11 | -0.188981E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -850340344.6 | 59.95 | 0.00 | 0.00 |
| June | 0.188292E+11 | -0.180075E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -821694914.4 | 59.95 | 0.00 | 0.00 |
| July | 0.193733E+11 | -0.185132E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -860085555.8 | 59.95 | 0.00 | 0.00 |
| August | 0.195022E+11 | -0.186421E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -860162741.9 | 59.95 | 0.00 | 0.00 |
| September | 0.191765E+11 | -0.183445E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -831988363.2 | 59.95 | 0.00 | 0.00 |
| October | 0.202360E+11 | -0.193715E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -864568139.7 | 59.95 | 0.00 | 0.00 |
| November | 0.199740E+11 | -0.191381E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -835919546.1 | 59.95 | 0.00 | 0.00 |
| December | 0.209262E+11 | -0.200606E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -865619670.4 | 59.95 | 0.00 | 0.00 |
| Annual Sum or Average | 0.237714E+12 | -0.227608E+12 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.101059E+11 | 59.95 | 0.00 | 0.00 |
| Minimum of Months | 0.188292E+11 | -0.201485E+11 | 0.00 | 0.00 | 672.00 | 0.00 | -865619670.4 | 59.95 | 0.00 | 0.00 |
| Maximum of Months | 0.210116E+11 | -0.180075E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -774343990.9 | 59.95 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
| January | 350.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 321.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 361.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 358.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 376.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 370.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 383.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 369.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 357.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 356.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 337.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 349.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 4292.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 321.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 383.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1 HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2 HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1 HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2 HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1 HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2 HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1 HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2 HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1 HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2 HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1 HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2 HEATING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.489624E+10 | 0.400777E+10 | 6487.75 | 02-JAN-08:62 | 4198.44 | 0.00 |
| February | 0.00 | 0.00 | 0.463927E+10 | 0.379716E+10 | 6430.40 | 10-FEB-08:32 | 4411.70 | 0.00 |
| March | 0.00 | 0.00 | 0.519164E+10 | 0.413994E+10 | 6506.58 | 15-MAR-07:22 | 4152.60 | 0.00 |
| April | 0.00 | 0.00 | 0.525246E+10 | 0.397657E+10 | 6230.69 | 14-APR-16:52 | 4749.24 | 0.00 |
| May | 0.00 | 0.00 | 0.565174E+10 | 0.408329E+10 | 6414.78 | 31-MAY-21:42 | 4459.74 | 0.00 |
| June | 0.00 | 0.00 | 0.555914E+10 | 0.403546E+10 | 6476.36 | 27-JUN-07:12 | 4161.55 | 0.00 |
| July | 0.00 | 0.00 | 0.495111E+10 | 0.378547E+10 | 6457.78 | 13-JUL-06:52 | 4256.28 | 0.00 |
| August | 0.00 | 0.00 | 0.523417E+10 | 0.374955E+10 | 6586.14 | 20-AUG-13:12 | 3773.08 | 0.00 |
| September | 0.00 | 0.00 | 0.509718E+10 | 0.375151E+10 | 6541.97 | 15-SEP-21:52 | 4015.17 | 0.00 |
| October | 0.00 | 0.00 | 0.501737E+10 | 0.370856E+10 | 6593.79 | 23-OCT-07:52 | 3801.16 | 0.00 |
| November | 0.00 | 0.00 | 0.489585E+10 | 0.377959E+10 | 6493.42 | 26-NOV-10:02 | 4201.25 | 0.00 |
| December | 0.00 | 0.00 | 0.488334E+10 | 0.391771E+10 | 6521.08 | 20-DEC-08:32 | 4122.62 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.612695E+11 | 0.467326E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.463927E+10 | 0.370856E+10 | 6230.69 | 3773.08 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.565174E+10 | 0.413994E+10 | 6593.79 | 4749.24 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.412229E+10 | 0.328003E+10 | 6512.49 | 08-JAN-08:42 | 4222.79 | 0.00 |
| February | 0.00 | 0.00 | 0.406505E+10 | 0.325136E+10 | 6474.79 | 10-FEB-08:42 | 4327.74 | 0.00 |
| March | 0.00 | 0.00 | 0.492169E+10 | 0.387899E+10 | 6536.97 | 15-MAR-07:22 | 4126.32 | 0.00 |
| April | 0.00 | 0.00 | 0.531256E+10 | 0.402967E+10 | 6260.34 | 14-APR-16:52 | 4726.55 | 0.00 |
| May | 0.00 | 0.00 | 0.592936E+10 | 0.433601E+10 | 6413.81 | 31-MAY-21:42 | 4526.47 | 0.00 |
| June | 0.00 | 0.00 | 0.603373E+10 | 0.447190E+10 | 6480.26 | 27-JUN-07:12 | 4228.64 | 0.00 |
| July | 0.00 | 0.00 | 0.523516E+10 | 0.404862E+10 | 6466.32 | 13-JUL-06:52 | 4308.20 | 0.00 |
| August | 0.00 | 0.00 | 0.540678E+10 | 0.390221E+10 | 6592.83 | 20-AUG-13:12 | 3836.12 | 0.00 |
| September | 0.00 | 0.00 | 0.504341E+10 | 0.369893E+10 | 6567.20 | 15-SEP-21:52 | 4007.92 | 0.00 |
| October | 0.00 | 0.00 | 0.473823E+10 | 0.344802E+10 | 6629.54 | 23-OCT-08:62 | 3751.74 | 0.00 |
| November | 0.00 | 0.00 | 0.435931E+10 | 0.327661E+10 | 6526.01 | 26-NOV-10:42 | 4137.41 | 0.00 |
| December | 0.00 | 0.00 | 0.411290E+10 | 0.319458E+10 | 6571.90 | 20-DEC-08:42 | 4022.24 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.592805E+11 | 0.448169E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.406505E+10 | 0.319458E+10 | 6260.34 | 3751.74 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.603373E+10 | 0.447190E+10 | 6629.54 | 4726.55 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.376448E+10 | 0.300136E+10 | 8016.72 | 09-JAN-07:01 | 4342.16 | 0.00 |
| February | 0.00 | 0.00 | 0.367906E+10 | 0.292934E+10 | 8016.72 | 06-FEB-07:01 | 4851.07 | 0.00 |
| March | 0.00 | 0.00 | 0.430603E+10 | 0.332713E+10 | 8016.90 | 15-MAR-06:01 | 4035.66 | 0.00 |
| April | 0.00 | 0.00 | 0.409933E+10 | 0.297514E+10 | 8013.46 | 24-APR-06:01 | 4142.92 | 0.00 |
| May | 0.00 | 0.00 | 0.481329E+10 | 0.326315E+10 | 8016.66 | 09-MAY-06:03 | 3763.45 | 0.00 |
| June | 0.00 | 0.00 | 0.477888E+10 | 0.324829E+10 | 8016.90 | 21-JUN-06:02 | 3894.30 | 0.00 |
| July | 0.00 | 0.00 | 0.371369E+10 | 0.269643E+10 | 8016.66 | 12-JUL-06:01 | 4091.28 | 0.00 |
| August | 0.00 | 0.00 | 0.446832E+10 | 0.301512E+10 | 8016.29 | 30-AUG-06:01 | 3875.37 | 0.00 |
| September | 0.00 | 0.00 | 0.399520E+10 | 0.275944E+10 | 8016.53 | 18-SEP-06:11 | 3415.32 | 0.00 |
| October | 0.00 | 0.00 | 0.397098E+10 | 0.276810E+10 | 8016.90 | 23-OCT-06:01 | 4100.16 | 0.00 |
| November | 0.00 | 0.00 | 0.384307E+10 | 0.282539E+10 | 8016.86 | 06-NOV-07:01 | 4760.64 | 0.00 |
| December | 0.00 | 0.00 | 0.362844E+10 | 0.283893E+10 | 8016.90 | 04-DEC-07:01 | 4434.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.490608E+11 | 0.356478E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.362844E+10 | 0.269643E+10 | 8013.46 | 3415.32 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.481329E+10 | 0.332713E+10 | 8016.90 | 4851.07 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.410509E+10 | 0.326133E+10 | 6191.78 | 02-JAN-08:62 | 3991.80 | 0.00 |
| February | 0.00 | 0.00 | 0.406508E+10 | 0.324882E+10 | 6151.42 | 10-FEB-08:42 | 4136.06 | 0.00 |
| March | 0.00 | 0.00 | 0.489716E+10 | 0.385416E+10 | 6212.15 | 15-MAR-07:22 | 3939.31 | 0.00 |
| April | 0.00 | 0.00 | 0.531625E+10 | 0.403171E+10 | 5958.90 | 14-APR-16:52 | 4476.17 | 0.00 |
| May | 0.00 | 0.00 | 0.594990E+10 | 0.435398E+10 | 6107.89 | 31-MAY-21:42 | 4278.41 | 0.00 |
| June | 0.00 | 0.00 | 0.605849E+10 | 0.449355E+10 | 6159.11 | 27-JUN-07:12 | 4032.67 | 0.00 |
| July | 0.00 | 0.00 | 0.524686E+10 | 0.405814E+10 | 6143.47 | 13-JUL-06:52 | 4116.98 | 0.00 |
| August | 0.00 | 0.00 | 0.543245E+10 | 0.392464E+10 | 6266.49 | 20-AUG-13:12 | 3655.55 | 0.00 |
| September | 0.00 | 0.00 | 0.507125E+10 | 0.372369E+10 | 6248.97 | 15-SEP-21:52 | 3797.26 | 0.00 |
| October | 0.00 | 0.00 | 0.474137E+10 | 0.344973E+10 | 6303.81 | 23-OCT-08:62 | 3570.14 | 0.00 |
| November | 0.00 | 0.00 | 0.436612E+10 | 0.328089E+10 | 6201.95 | 26-NOV-10:42 | 3946.15 | 0.00 |
| December | 0.00 | 0.00 | 0.410416E+10 | 0.318359E+10 | 6235.22 | 20-DEC-08:42 | 3877.73 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.593542E+11 | 0.448642E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.406508E+10 | 0.318359E+10 | 5958.90 | 3570.14 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.605849E+10 | 0.449355E+10 | 6303.81 | 4476.17 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.353324E+10 | 0.273963E+10 | 5594.14 | 02-JAN-08:62 | 3568.56 | 0.00 |
| February | 0.00 | 0.00 | 0.343478E+10 | 0.267255E+10 | 5567.99 | 10-FEB-08:42 | 3673.23 | 0.00 |
| March | 0.00 | 0.00 | 0.408335E+10 | 0.312456E+10 | 5616.18 | 15-MAR-07:22 | 3507.45 | 0.00 |
| April | 0.00 | 0.00 | 0.444580E+10 | 0.325708E+10 | 5398.18 | 14-APR-16:52 | 3953.01 | 0.00 |
| May | 0.00 | 0.00 | 0.508731E+10 | 0.360390E+10 | 5532.81 | 31-MAY-21:42 | 3813.17 | 0.00 |
| June | 0.00 | 0.00 | 0.516888E+10 | 0.371369E+10 | 5575.14 | 27-JUN-07:12 | 3581.22 | 0.00 |
| July | 0.00 | 0.00 | 0.452036E+10 | 0.340305E+10 | 5561.62 | 13-JUL-06:52 | 3653.63 | 0.00 |
| August | 0.00 | 0.00 | 0.465000E+10 | 0.325237E+10 | 5660.37 | 20-AUG-13:12 | 3295.31 | 0.00 |
| September | 0.00 | 0.00 | 0.432448E+10 | 0.306375E+10 | 5651.07 | 15-SEP-21:52 | 3379.96 | 0.00 |
| October | 0.00 | 0.00 | 0.412398E+10 | 0.290913E+10 | 5691.09 | 23-OCT-08:62 | 3219.81 | 0.00 |
| November | 0.00 | 0.00 | 0.379227E+10 | 0.276864E+10 | 5608.06 | 26-NOV-10:42 | 3534.15 | 0.00 |
| December | 0.00 | 0.00 | 0.356392E+10 | 0.269404E+10 | 5643.09 | 24-DEC-09:12 | 3406.50 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.507284E+11 | 0.372024E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.343478E+10 | 0.267255E+10 | 5398.18 | 3219.81 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.516888E+10 | 0.371369E+10 | 5691.09 | 3953.01 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.353467E+10 | 0.274081E+10 | 5587.69 | 02-JAN-08:62 | 3564.54 | 0.00 |
| February | 0.00 | 0.00 | 0.343611E+10 | 0.267365E+10 | 5561.54 | 10-FEB-08:42 | 3668.90 | 0.00 |
| March | 0.00 | 0.00 | 0.408292E+10 | 0.312407E+10 | 5609.71 | 15-MAR-07:22 | 3503.86 | 0.00 |
| April | 0.00 | 0.00 | 0.444625E+10 | 0.325739E+10 | 5391.85 | 14-APR-16:52 | 3948.38 | 0.00 |
| May | 0.00 | 0.00 | 0.508831E+10 | 0.360471E+10 | 5526.58 | 31-MAY-21:42 | 3808.12 | 0.00 |
| June | 0.00 | 0.00 | 0.517004E+10 | 0.371465E+10 | 5568.66 | 27-JUN-07:12 | 3577.06 | 0.00 |
| July | 0.00 | 0.00 | 0.452121E+10 | 0.340370E+10 | 5555.09 | 13-JUL-06:52 | 3649.58 | 0.00 |
| August | 0.00 | 0.00 | 0.465129E+10 | 0.325343E+10 | 5653.64 | 20-AUG-13:12 | 3291.85 | 0.00 |
| September | 0.00 | 0.00 | 0.432593E+10 | 0.306497E+10 | 5644.62 | 15-SEP-21:52 | 3375.84 | 0.00 |
| October | 0.00 | 0.00 | 0.412432E+10 | 0.290934E+10 | 5684.53 | 23-OCT-08:62 | 3216.00 | 0.00 |
| November | 0.00 | 0.00 | 0.379318E+10 | 0.276935E+10 | 5601.32 | 26-NOV-10:42 | 3530.57 | 0.00 |
| December | 0.00 | 0.00 | 0.356510E+10 | 0.269497E+10 | 5636.69 | 24-DEC-09:12 | 3402.03 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.507393E+11 | 0.372110E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.343611E+10 | 0.267365E+10 | 5391.85 | 3216.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.517004E+10 | 0.371465E+10 | 5684.53 | 3948.38 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.435184E+10 | 0.349103E+10 | 5603.38 | 02-JAN-08:62 | 3584.11 | 0.00 |
| February | 0.00 | 0.00 | 0.404789E+10 | 0.323850E+10 | 5555.03 | 10-FEB-08:32 | 3758.71 | 0.00 |
| March | 0.00 | 0.00 | 0.438680E+10 | 0.340200E+10 | 5620.96 | 15-MAR-07:22 | 3541.36 | 0.00 |
| April | 0.00 | 0.00 | 0.440822E+10 | 0.321539E+10 | 5397.51 | 14-APR-16:52 | 3967.95 | 0.00 |
| May | 0.00 | 0.00 | 0.482646E+10 | 0.336001E+10 | 5571.36 | 31-MAY-21:42 | 3711.76 | 0.00 |
| June | 0.00 | 0.00 | 0.470303E+10 | 0.328203E+10 | 5613.08 | 25-JUN-21:42 | 3534.64 | 0.00 |
| July | 0.00 | 0.00 | 0.425227E+10 | 0.314782E+10 | 5581.84 | 13-JUL-06:52 | 3605.62 | 0.00 |
| August | 0.00 | 0.00 | 0.449519E+10 | 0.310836E+10 | 5685.92 | 20-AUG-13:12 | 3242.40 | 0.00 |
| September | 0.00 | 0.00 | 0.440263E+10 | 0.312801E+10 | 5658.17 | 15-SEP-21:52 | 3396.01 | 0.00 |
| October | 0.00 | 0.00 | 0.443590E+10 | 0.318587E+10 | 5688.96 | 23-OCT-07:52 | 3272.79 | 0.00 |
| November | 0.00 | 0.00 | 0.436832E+10 | 0.329169E+10 | 5604.63 | 26-NOV-10:02 | 3599.85 | 0.00 |
| December | 0.00 | 0.00 | 0.437981E+10 | 0.344139E+10 | 5624.23 | 20-DEC-08:32 | 3549.36 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.530583E+11 | 0.392921E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.404789E+10 | 0.310836E+10 | 5397.51 | 3242.40 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.482646E+10 | 0.349103E+10 | 5688.96 | 3967.95 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.464603E+10 | 0.376795E+10 | 5621.93 | 02-JAN-08:62 | 3713.94 | 0.00 |
| February | 0.00 | 0.00 | 0.431300E+10 | 0.348786E+10 | 5589.06 | 10-FEB-08:32 | 3834.73 | 0.00 |
| March | 0.00 | 0.00 | 0.468288E+10 | 0.367677E+10 | 5649.88 | 15-MAR-07:22 | 3636.11 | 0.00 |
| April | 0.00 | 0.00 | 0.472108E+10 | 0.350174E+10 | 5433.65 | 14-APR-16:52 | 4043.54 | 0.00 |
| May | 0.00 | 0.00 | 0.515369E+10 | 0.365698E+10 | 5598.92 | 31-MAY-21:42 | 3811.41 | 0.00 |
| June | 0.00 | 0.00 | 0.501229E+10 | 0.356301E+10 | 5637.13 | 25-JUN-21:42 | 3623.43 | 0.00 |
| July | 0.00 | 0.00 | 0.456570E+10 | 0.343570E+10 | 5608.65 | 13-JUL-06:52 | 3717.53 | 0.00 |
| August | 0.00 | 0.00 | 0.478990E+10 | 0.337434E+10 | 5704.40 | 20-AUG-13:12 | 3356.58 | 0.00 |
| September | 0.00 | 0.00 | 0.470381E+10 | 0.340236E+10 | 5695.90 | 15-SEP-21:52 | 3466.07 | 0.00 |
| October | 0.00 | 0.00 | 0.474037E+10 | 0.346384E+10 | 5711.01 | 23-OCT-07:52 | 3391.08 | 0.00 |
| November | 0.00 | 0.00 | 0.465371E+10 | 0.355645E+10 | 5636.89 | 26-NOV-10:02 | 3683.26 | 0.00 |
| December | 0.00 | 0.00 | 0.465062E+10 | 0.369457E+10 | 5655.93 | 20-DEC-08:32 | 3634.59 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.566331E+11 | 0.425816E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.431300E+10 | 0.337434E+10 | 5433.65 | 3356.58 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.515369E+10 | 0.376795E+10 | 5711.01 | 4043.54 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.966162E+10 | 0.784877E+10 | 14272.61 | 08-JAN-10:12 | 8790.32 | 0.00 |
| February | 0.00 | 0.00 | 0.912978E+10 | 0.741016E+10 | 14132.70 | 10-FEB-08:32 | 9299.77 | 0.00 |
| March | 0.00 | 0.00 | 0.102775E+11 | 0.810431E+10 | 14281.94 | 15-MAR-07:22 | 8561.08 | 0.00 |
| April | 0.00 | 0.00 | 0.103365E+11 | 0.771446E+10 | 13652.51 | 14-APR-16:52 | 10176.65 | 0.00 |
| May | 0.00 | 0.00 | 0.109853E+11 | 0.776589E+10 | 14125.81 | 31-MAY-21:42 | 9347.12 | 0.00 |
| June | 0.00 | 0.00 | 0.106994E+11 | 0.758014E+10 | 14230.01 | 25-JUN-21:42 | 8929.31 | 0.00 |
| July | 0.00 | 0.00 | 0.934197E+10 | 0.699445E+10 | 14154.39 | 22-JUL-08:62 | 8962.41 | 0.00 |
| August | 0.00 | 0.00 | 0.996730E+10 | 0.693940E+10 | 14567.43 | 20-AUG-13:12 | 7541.40 | 0.00 |
| September | 0.00 | 0.00 | 0.970527E+10 | 0.698458E+10 | 14412.99 | 18-SEP-08:32 | 8195.69 | 0.00 |
| October | 0.00 | 0.00 | 0.976591E+10 | 0.710495E+10 | 14525.82 | 23-OCT-07:52 | 7608.53 | 0.00 |
| November | 0.00 | 0.00 | 0.953132E+10 | 0.726907E+10 | 14288.97 | 26-NOV-10:02 | 8764.48 | 0.00 |
| December | 0.00 | 0.00 | 0.953131E+10 | 0.757559E+10 | 14389.73 | 20-DEC-08:32 | 8430.95 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.118933E+12 | 0.892918E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.912978E+10 | 0.693940E+10 | 13652.51 | 7541.40 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.109853E+11 | 0.810431E+10 | 14567.43 | 10176.65 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.799467E+10 | 0.629330E+10 | 14332.96 | 07-JAN-09:12 | 8645.85 | 0.00 |
| February | 0.00 | 0.00 | 0.790502E+10 | 0.625494E+10 | 14253.46 | 10-FEB-08:42 | 8960.28 | 0.00 |
| March | 0.00 | 0.00 | 0.969784E+10 | 0.755108E+10 | 14363.44 | 15-MAR-07:22 | 8489.54 | 0.00 |
| April | 0.00 | 0.00 | 0.104348E+11 | 0.780310E+10 | 13736.94 | 14-APR-16:52 | 10150.96 | 0.00 |
| May | 0.00 | 0.00 | 0.115378E+11 | 0.826827E+10 | 14122.34 | 31-MAY-21:42 | 9618.96 | 0.00 |
| June | 0.00 | 0.00 | 0.116660E+11 | 0.846429E+10 | 14291.89 | 27-JUN-07:12 | 8785.21 | 0.00 |
| July | 0.00 | 0.00 | 0.990264E+10 | 0.751253E+10 | 14197.15 | 13-JUL-06:52 | 9015.50 | 0.00 |
| August | 0.00 | 0.00 | 0.103007E+11 | 0.723324E+10 | 14616.76 | 20-AUG-13:12 | 7575.82 | 0.00 |
| September | 0.00 | 0.00 | 0.956219E+10 | 0.685032E+10 | 14498.82 | 18-SEP-08:32 | 8133.19 | 0.00 |
| October | 0.00 | 0.00 | 0.915188E+10 | 0.653909E+10 | 14615.50 | 23-OCT-08:62 | 7527.11 | 0.00 |
| November | 0.00 | 0.00 | 0.837398E+10 | 0.619285E+10 | 14387.68 | 26-NOV-10:42 | 8634.08 | 0.00 |
| December | 0.00 | 0.00 | 0.787346E+10 | 0.603173E+10 | 14496.60 | 20-DEC-08:42 | 8029.88 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.114401E+12 | 0.849947E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.787346E+10 | 0.603173E+10 | 13736.94 | 7527.11 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.116660E+11 | 0.846429E+10 | 14616.76 | 10150.96 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.962524E+10 | 0.780715E+10 | 13443.64 | 08-JAN-10:12 | 8507.42 | 0.00 |
| February | 0.00 | 0.00 | 0.912968E+10 | 0.740429E+10 | 13333.35 | 10-FEB-08:32 | 8905.30 | 0.00 |
| March | 0.00 | 0.00 | 0.102195E+11 | 0.804482E+10 | 13512.85 | 15-MAR-07:22 | 8164.53 | 0.00 |
| April | 0.00 | 0.00 | 0.103430E+11 | 0.771623E+10 | 12925.20 | 14-APR-16:52 | 9522.24 | 0.00 |
| May | 0.00 | 0.00 | 0.110323E+11 | 0.780497E+10 | 13386.10 | 31-MAY-21:42 | 8735.69 | 0.00 |
| June | 0.00 | 0.00 | 0.107609E+11 | 0.763136E+10 | 13546.68 | 25-JUN-21:42 | 8148.02 | 0.00 |
| July | 0.00 | 0.00 | 0.937246E+10 | 0.701798E+10 | 13399.52 | 19-JUL-21:52 | 8682.28 | 0.00 |
| August | 0.00 | 0.00 | 0.100289E+11 | 0.699129E+10 | 13754.34 | 20-AUG-13:12 | 7227.18 | 0.00 |
| September | 0.00 | 0.00 | 0.976677E+10 | 0.703786E+10 | 13609.72 | 15-SEP-20:52 | 7903.05 | 0.00 |
| October | 0.00 | 0.00 | 0.977438E+10 | 0.710933E+10 | 13739.14 | 23-OCT-07:52 | 7204.39 | 0.00 |
| November | 0.00 | 0.00 | 0.954100E+10 | 0.727349E+10 | 13499.26 | 26-NOV-10:02 | 8335.86 | 0.00 |
| December | 0.00 | 0.00 | 0.951306E+10 | 0.755165E+10 | 13541.39 | 20-DEC-08:32 | 8229.89 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.119107E+12 | 0.893904E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.912968E+10 | 0.699129E+10 | 12925.20 | 7204.39 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.110323E+11 | 0.804482E+10 | 13754.34 | 9522.24 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.795107E+10 | 0.624877E+10 | 13497.11 | 07-JAN-09:12 | 8412.82 | 0.00 |
| February | 0.00 | 0.00 | 0.790133E+10 | 0.624828E+10 | 13441.68 | 10-FEB-08:42 | 8692.85 | 0.00 |
| March | 0.00 | 0.00 | 0.963626E+10 | 0.749313E+10 | 13575.10 | 15-MAR-07:22 | 8097.43 | 0.00 |
| April | 0.00 | 0.00 | 0.104368E+11 | 0.780553E+10 | 12994.72 | 14-APR-16:52 | 9505.41 | 0.00 |
| May | 0.00 | 0.00 | 0.115791E+11 | 0.830769E+10 | 13365.36 | 31-MAY-21:42 | 9005.58 | 0.00 |
| June | 0.00 | 0.00 | 0.117204E+11 | 0.851519E+10 | 13491.93 | 27-JUN-07:12 | 8358.09 | 0.00 |
| July | 0.00 | 0.00 | 0.992739E+10 | 0.753588E+10 | 13427.80 | 13-JUL-06:52 | 8638.03 | 0.00 |
| August | 0.00 | 0.00 | 0.103575E+11 | 0.728575E+10 | 13789.11 | 20-AUG-13:12 | 7248.71 | 0.00 |
| September | 0.00 | 0.00 | 0.961970E+10 | 0.690469E+10 | 13679.61 | 15-SEP-20:52 | 7840.21 | 0.00 |
| October | 0.00 | 0.00 | 0.915755E+10 | 0.654482E+10 | 13808.52 | 23-OCT-08:62 | 7127.79 | 0.00 |
| November | 0.00 | 0.00 | 0.838289E+10 | 0.619967E+10 | 13577.22 | 26-NOV-10:42 | 8213.77 | 0.00 |
| December | 0.00 | 0.00 | 0.785388E+10 | 0.600768E+10 | 13705.02 | 20-DEC-08:42 | 7815.82 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.114524E+12 | 0.850971E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.785388E+10 | 0.600768E+10 | 12994.72 | 7127.79 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.117204E+11 | 0.851519E+10 | 13808.52 | 9505.41 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.674060E+10 | 0.516982E+10 | 12192.89 | 27-JAN-08:42 | 7349.27 | 0.00 |
| February | 0.00 | 0.00 | 0.655459E+10 | 0.504299E+10 | 12140.21 | 10-FEB-08:42 | 7579.93 | 0.00 |
| March | 0.00 | 0.00 | 0.785788E+10 | 0.593675E+10 | 12232.07 | 15-MAR-07:22 | 7222.44 | 0.00 |
| April | 0.00 | 0.00 | 0.854461E+10 | 0.616390E+10 | 11746.14 | 14-APR-16:52 | 8366.02 | 0.00 |
| May | 0.00 | 0.00 | 0.974097E+10 | 0.676308E+10 | 12082.61 | 31-MAY-21:42 | 8008.20 | 0.00 |
| June | 0.00 | 0.00 | 0.985777E+10 | 0.693814E+10 | 12186.49 | 25-JUN-21:42 | 7619.72 | 0.00 |
| July | 0.00 | 0.00 | 0.849022E+10 | 0.627893E+10 | 12101.20 | 13-JUL-06:52 | 7641.04 | 0.00 |
| August | 0.00 | 0.00 | 0.877265E+10 | 0.598073E+10 | 12433.94 | 20-AUG-13:12 | 6486.84 | 0.00 |
| September | 0.00 | 0.00 | 0.812427E+10 | 0.562518E+10 | 12424.17 | 15-SEP-20:52 | 6759.01 | 0.00 |
| October | 0.00 | 0.00 | 0.786929E+10 | 0.545334E+10 | 12435.05 | 23-OCT-08:62 | 6463.54 | 0.00 |
| November | 0.00 | 0.00 | 0.720229E+10 | 0.517429E+10 | 12282.35 | 26-NOV-10:42 | 7267.38 | 0.00 |
| December | 0.00 | 0.00 | 0.674970E+10 | 0.503327E+10 | 12350.48 | 24-DEC-09:12 | 6817.07 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.965048E+11 | 0.695604E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.655459E+10 | 0.503327E+10 | 11746.14 | 6463.54 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.985777E+10 | 0.693814E+10 | 12435.05 | 8366.02 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.674484E+10 | 0.517345E+10 | 12178.27 | 27-JAN-08:42 | 7342.47 | 0.00 |
| February | 0.00 | 0.00 | 0.655831E+10 | 0.504614E+10 | 12125.85 | 10-FEB-08:42 | 7571.82 | 0.00 |
| March | 0.00 | 0.00 | 0.785713E+10 | 0.593590E+10 | 12216.98 | 15-MAR-07:22 | 7214.82 | 0.00 |
| April | 0.00 | 0.00 | 0.854556E+10 | 0.616459E+10 | 11731.39 | 14-APR-16:52 | 8354.72 | 0.00 |
| May | 0.00 | 0.00 | 0.974300E+10 | 0.676475E+10 | 12068.23 | 31-MAY-21:42 | 7995.92 | 0.00 |
| June | 0.00 | 0.00 | 0.986025E+10 | 0.694020E+10 | 12172.26 | 25-JUN-21:42 | 7607.88 | 0.00 |
| July | 0.00 | 0.00 | 0.849197E+10 | 0.628030E+10 | 12086.43 | 13-JUL-06:52 | 7632.88 | 0.00 |
| August | 0.00 | 0.00 | 0.877537E+10 | 0.598295E+10 | 12418.63 | 20-AUG-13:12 | 6479.80 | 0.00 |
| September | 0.00 | 0.00 | 0.812714E+10 | 0.562756E+10 | 12409.00 | 15-SEP-20:52 | 6749.86 | 0.00 |
| October | 0.00 | 0.00 | 0.787020E+10 | 0.545395E+10 | 12419.80 | 23-OCT-08:62 | 6455.31 | 0.00 |
| November | 0.00 | 0.00 | 0.720435E+10 | 0.517597E+10 | 12264.13 | 26-NOV-10:42 | 7269.22 | 0.00 |
| December | 0.00 | 0.00 | 0.675330E+10 | 0.503625E+10 | 12335.06 | 24-DEC-09:12 | 6813.23 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.965314E+11 | 0.695820E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.655831E+10 | 0.503625E+10 | 11731.39 | 6455.31 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.986025E+10 | 0.694020E+10 | 12419.80 | 8354.72 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.845216E+10 | 0.673528E+10 | 12212.09 | 08-JAN-10:12 | 7507.82 | 0.00 |
| February | 0.00 | 0.00 | 0.781788E+10 | 0.620555E+10 | 12112.67 | 10-FEB-08:32 | 7841.93 | 0.00 |
| March | 0.00 | 0.00 | 0.846780E+10 | 0.649311E+10 | 12218.05 | 15-MAR-07:22 | 7296.34 | 0.00 |
| April | 0.00 | 0.00 | 0.846036E+10 | 0.607414E+10 | 11721.44 | 14-APR-16:52 | 8372.08 | 0.00 |
| May | 0.00 | 0.00 | 0.919132E+10 | 0.625612E+10 | 12142.53 | 31-MAY-21:42 | 7699.15 | 0.00 |
| June | 0.00 | 0.00 | 0.888452E+10 | 0.604696E+10 | 12290.85 | 25-JUN-21:42 | 7238.92 | 0.00 |
| July | 0.00 | 0.00 | 0.793303E+10 | 0.575564E+10 | 12170.99 | 19-JUL-21:52 | 7638.11 | 0.00 |
| August | 0.00 | 0.00 | 0.844677E+10 | 0.568333E+10 | 12466.76 | 20-AUG-13:12 | 6404.52 | 0.00 |
| September | 0.00 | 0.00 | 0.828527E+10 | 0.575835E+10 | 12404.65 | 15-SEP-20:52 | 6830.25 | 0.00 |
| October | 0.00 | 0.00 | 0.851293E+10 | 0.602198E+10 | 12411.00 | 23-OCT-07:52 | 6571.53 | 0.00 |
| November | 0.00 | 0.00 | 0.839918E+10 | 0.625811E+10 | 12217.52 | 26-NOV-10:02 | 7517.70 | 0.00 |
| December | 0.00 | 0.00 | 0.845687E+10 | 0.659127E+10 | 12298.04 | 20-DEC-08:32 | 7257.33 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.101308E+12 | 0.738799E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.781788E+10 | 0.568333E+10 | 11721.44 | 6404.52 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.919132E+10 | 0.673528E+10 | 12466.76 | 8372.08 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.845519E+10 | 0.673773E+10 | 12196.51 | 08-JAN-10:12 | 7501.21 | 0.00 |
| February | 0.00 | 0.00 | 0.782095E+10 | 0.620816E+10 | 12098.60 | 10-FEB-08:32 | 7833.33 | 0.00 |
| March | 0.00 | 0.00 | 0.846703E+10 | 0.649220E+10 | 12203.30 | 15-MAR-07:22 | 7288.66 | 0.00 |
| April | 0.00 | 0.00 | 0.846134E+10 | 0.607481E+10 | 11706.98 | 14-APR-16:52 | 8360.90 | 0.00 |
| May | 0.00 | 0.00 | 0.919343E+10 | 0.625779E+10 | 12128.18 | 31-MAY-21:42 | 7686.57 | 0.00 |
| June | 0.00 | 0.00 | 0.888712E+10 | 0.604905E+10 | 12276.33 | 25-JUN-21:42 | 7225.86 | 0.00 |
| July | 0.00 | 0.00 | 0.793484E+10 | 0.575701E+10 | 12156.45 | 19-JUL-21:52 | 7623.30 | 0.00 |
| August | 0.00 | 0.00 | 0.844955E+10 | 0.568554E+10 | 12451.75 | 20-AUG-13:12 | 6397.65 | 0.00 |
| September | 0.00 | 0.00 | 0.828815E+10 | 0.576070E+10 | 12389.84 | 15-SEP-20:52 | 6821.04 | 0.00 |
| October | 0.00 | 0.00 | 0.851383E+10 | 0.602255E+10 | 12396.10 | 23-OCT-07:52 | 6563.21 | 0.00 |
| November | 0.00 | 0.00 | 0.840103E+10 | 0.625954E+10 | 12202.49 | 26-NOV-10:02 | 7509.16 | 0.00 |
| December | 0.00 | 0.00 | 0.845934E+10 | 0.659352E+10 | 12267.71 | 20-DEC-08:32 | 7308.31 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.101332E+12 | 0.738986E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.782095E+10 | 0.568554E+10 | 11706.98 | 6397.65 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.919343E+10 | 0.673773E+10 | 12451.75 | 8360.90 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.508891E+10 | 0.416891E+10 | 7639.90 | 07-JAN-08:32 | 4625.22 | 0.00 |
| February | 0.00 | 0.00 | 0.484546E+10 | 0.396533E+10 | 7602.18 | 10-FEB-08:32 | 4753.86 | 0.00 |
| March | 0.00 | 0.00 | 0.556187E+10 | 0.442853E+10 | 7687.87 | 15-MAR-07:22 | 4363.04 | 0.00 |
| April | 0.00 | 0.00 | 0.564793E+10 | 0.427300E+10 | 7304.29 | 14-APR-16:52 | 5395.99 | 0.00 |
| May | 0.00 | 0.00 | 0.596808E+10 | 0.427544E+10 | 7546.83 | 31-MAY-21:42 | 4950.58 | 0.00 |
| June | 0.00 | 0.00 | 0.582794E+10 | 0.418531E+10 | 7649.12 | 27-JUN-07:12 | 4475.37 | 0.00 |
| July | 0.00 | 0.00 | 0.500680E+10 | 0.378868E+10 | 7625.58 | 22-JUL-08:62 | 4622.01 | 0.00 |
| August | 0.00 | 0.00 | 0.532840E+10 | 0.374177E+10 | 7777.03 | 20-AUG-13:12 | 4041.07 | 0.00 |
| September | 0.00 | 0.00 | 0.520736E+10 | 0.379482E+10 | 7701.78 | 18-SEP-08:32 | 4408.05 | 0.00 |
| October | 0.00 | 0.00 | 0.515451E+10 | 0.378375E+10 | 7798.71 | 23-OCT-07:52 | 4014.99 | 0.00 |
| November | 0.00 | 0.00 | 0.500823E+10 | 0.385289E+10 | 7662.71 | 02-NOV-07:32 | 4501.23 | 0.00 |
| December | 0.00 | 0.00 | 0.497484E+10 | 0.398898E+10 | 7717.06 | 20-DEC-08:32 | 4375.05 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.636203E+11 | 0.482474E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.484546E+10 | 0.374177E+10 | 7304.29 | 4014.99 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.596808E+10 | 0.442853E+10 | 7798.71 | 5395.99 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.421829E+10 | 0.335217E+10 | 7741.58 | 27-JAN-08:42 | 4536.16 | 0.00 |
| February | 0.00 | 0.00 | 0.420973E+10 | 0.336204E+10 | 7704.71 | 10-FEB-08:42 | 4699.69 | 0.00 |
| March | 0.00 | 0.00 | 0.526529E+10 | 0.414271E+10 | 7777.14 | 15-MAR-07:22 | 4348.98 | 0.00 |
| April | 0.00 | 0.00 | 0.570301E+10 | 0.432275E+10 | 7392.75 | 14-APR-16:52 | 5402.06 | 0.00 |
| May | 0.00 | 0.00 | 0.625981E+10 | 0.454301E+10 | 7589.70 | 31-MAY-21:42 | 5102.70 | 0.00 |
| June | 0.00 | 0.00 | 0.633345E+10 | 0.465154E+10 | 7723.27 | 27-JUN-07:12 | 4552.31 | 0.00 |
| July | 0.00 | 0.00 | 0.529969E+10 | 0.406071E+10 | 7694.94 | 22-JUL-08:62 | 4695.71 | 0.00 |
| August | 0.00 | 0.00 | 0.550336E+10 | 0.389714E+10 | 7863.09 | 20-AUG-13:12 | 4070.03 | 0.00 |
| September | 0.00 | 0.00 | 0.513225E+10 | 0.372326E+10 | 7790.99 | 18-SEP-08:32 | 4410.30 | 0.00 |
| October | 0.00 | 0.00 | 0.483780E+10 | 0.348869E+10 | 7886.62 | 23-OCT-08:62 | 4019.19 | 0.00 |
| November | 0.00 | 0.00 | 0.440577E+10 | 0.328844E+10 | 7764.13 | 02-NOV-07:42 | 4436.41 | 0.00 |
| December | 0.00 | 0.00 | 0.410830E+10 | 0.317786E+10 | 7843.39 | 20-DEC-08:42 | 4194.53 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.612768E+11 | 0.460103E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.410830E+10 | 0.317786E+10 | 7392.75 | 4019.19 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.633345E+10 | 0.465154E+10 | 7886.62 | 5402.06 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.506327E+10 | 0.413990E+10 | 7114.77 | 08-JAN-09:53 | 4657.28 | 0.00 |
| February | 0.00 | 0.00 | 0.484222E+10 | 0.395839E+10 | 6999.40 | 10-FEB-08:32 | 4527.45 | 0.00 |
| March | 0.00 | 0.00 | 0.552467E+10 | 0.439052E+10 | 7120.41 | 15-MAR-07:22 | 4088.02 | 0.00 |
| April | 0.00 | 0.00 | 0.564762E+10 | 0.427067E+10 | 6776.26 | 14-APR-16:52 | 4933.31 | 0.00 |
| May | 0.00 | 0.00 | 0.599196E+10 | 0.429573E+10 | 7003.64 | 31-MAY-21:42 | 4521.69 | 0.00 |
| June | 0.00 | 0.00 | 0.586354E+10 | 0.421604E+10 | 7072.87 | 27-JUN-07:12 | 4180.53 | 0.00 |
| July | 0.00 | 0.00 | 0.502406E+10 | 0.380252E+10 | 7051.69 | 22-JUL-08:62 | 4296.37 | 0.00 |
| August | 0.00 | 0.00 | 0.536358E+10 | 0.377203E+10 | 7192.40 | 20-AUG-13:12 | 3749.67 | 0.00 |
| September | 0.00 | 0.00 | 0.523999E+10 | 0.382379E+10 | 7113.99 | 18-SEP-08:32 | 4127.87 | 0.00 |
| October | 0.00 | 0.00 | 0.515881E+10 | 0.378619E+10 | 7214.91 | 23-OCT-07:52 | 3722.47 | 0.00 |
| November | 0.00 | 0.00 | 0.501041E+10 | 0.385254E+10 | 7090.55 | 26-NOV-08:32 | 4203.75 | 0.00 |
| December | 0.00 | 0.00 | 0.496382E+10 | 0.397322E+10 | 7104.12 | 17-DEC-08:42 | 4165.95 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.636939E+11 | 0.482816E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.484222E+10 | 0.377203E+10 | 6776.26 | 3722.47 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.599196E+10 | 0.439052E+10 | 7214.91 | 4933.31 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.418620E+10 | 0.331675E+10 | 7139.49 | 08-JAN-08:42 | 4344.63 | 0.00 |
| February | 0.00 | 0.00 | 0.420509E+10 | 0.335269E+10 | 7106.47 | 10-FEB-08:42 | 4436.47 | 0.00 |
| March | 0.00 | 0.00 | 0.522933E+10 | 0.410555E+10 | 7203.56 | 15-MAR-07:22 | 4076.18 | 0.00 |
| April | 0.00 | 0.00 | 0.570288E+10 | 0.432068E+10 | 6859.46 | 14-APR-16:52 | 4941.60 | 0.00 |
| May | 0.00 | 0.00 | 0.628340E+10 | 0.456348E+10 | 7051.32 | 31-MAY-21:42 | 4636.73 | 0.00 |
| June | 0.00 | 0.00 | 0.636848E+10 | 0.468249E+10 | 7137.71 | 27-JUN-07:12 | 4247.12 | 0.00 |
| July | 0.00 | 0.00 | 0.531678E+10 | 0.407473E+10 | 7115.71 | 22-JUL-08:62 | 4366.59 | 0.00 |
| August | 0.00 | 0.00 | 0.553875E+10 | 0.392782E+10 | 7260.51 | 20-AUG-13:12 | 3817.75 | 0.00 |
| September | 0.00 | 0.00 | 0.516564E+10 | 0.375287E+10 | 7196.89 | 18-SEP-08:32 | 4130.23 | 0.00 |
| October | 0.00 | 0.00 | 0.484336E+10 | 0.349194E+10 | 7295.91 | 23-OCT-08:62 | 3728.85 | 0.00 |
| November | 0.00 | 0.00 | 0.440997E+10 | 0.328907E+10 | 7166.98 | 26-NOV-08:52 | 4237.14 | 0.00 |
| December | 0.00 | 0.00 | 0.409231E+10 | 0.315676E+10 | 7233.88 | 20-DEC-08:42 | 4016.30 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.613422E+11 | 0.460348E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.409231E+10 | 0.315676E+10 | 6859.46 | 3728.85 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.636848E+10 | 0.468249E+10 | 7295.91 | 4941.60 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.357288E+10 | 0.277583E+10 | 6647.34 | 27-JAN-08:42 | 3932.53 | 0.00 |
| February | 0.00 | 0.00 | 0.351675E+10 | 0.274404E+10 | 6616.96 | 10-FEB-08:42 | 4069.29 | 0.00 |
| March | 0.00 | 0.00 | 0.431648E+10 | 0.331826E+10 | 6676.05 | 15-MAR-07:22 | 3803.88 | 0.00 |
| April | 0.00 | 0.00 | 0.472939E+10 | 0.348840E+10 | 6381.14 | 14-APR-16:52 | 4556.31 | 0.00 |
| May | 0.00 | 0.00 | 0.533091E+10 | 0.378155E+10 | 6544.24 | 31-MAY-21:42 | 4343.79 | 0.00 |
| June | 0.00 | 0.00 | 0.540281E+10 | 0.388362E+10 | 6631.19 | 27-JUN-07:12 | 3947.66 | 0.00 |
| July | 0.00 | 0.00 | 0.457840E+10 | 0.344081E+10 | 6604.85 | 22-JUL-08:62 | 4078.73 | 0.00 |
| August | 0.00 | 0.00 | 0.471850E+10 | 0.326945E+10 | 6751.58 | 20-AUG-13:12 | 3535.36 | 0.00 |
| September | 0.00 | 0.00 | 0.439877E+10 | 0.310745E+10 | 6692.56 | 18-SEP-08:32 | 3815.14 | 0.00 |
| October | 0.00 | 0.00 | 0.418779E+10 | 0.294695E+10 | 6758.39 | 23-OCT-08:62 | 3537.77 | 0.00 |
| November | 0.00 | 0.00 | 0.381023E+10 | 0.277554E+10 | 6666.01 | 02-NOV-07:42 | 3857.55 | 0.00 |
| December | 0.00 | 0.00 | 0.353500E+10 | 0.266901E+10 | 6732.51 | 20-DEC-08:42 | 3668.14 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.520979E+11 | 0.382009E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.351675E+10 | 0.266901E+10 | 6381.14 | 3535.36 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.540281E+10 | 0.388362E+10 | 6758.39 | 4556.31 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.357541E+10 | 0.277782E+10 | 6625.99 | 27-JAN-08:42 | 3920.99 | 0.00 |
| February | 0.00 | 0.00 | 0.351922E+10 | 0.274601E+10 | 6595.86 | 10-FEB-08:42 | 4057.32 | 0.00 |
| March | 0.00 | 0.00 | 0.431609E+10 | 0.331766E+10 | 6655.12 | 15-MAR-07:22 | 3792.50 | 0.00 |
| April | 0.00 | 0.00 | 0.473006E+10 | 0.348879E+10 | 6361.13 | 14-APR-16:52 | 4539.96 | 0.00 |
| May | 0.00 | 0.00 | 0.533225E+10 | 0.378253E+10 | 6524.44 | 31-MAY-21:42 | 4327.11 | 0.00 |
| June | 0.00 | 0.00 | 0.540457E+10 | 0.388499E+10 | 6610.17 | 27-JUN-07:12 | 3935.07 | 0.00 |
| July | 0.00 | 0.00 | 0.457964E+10 | 0.344168E+10 | 6584.01 | 22-JUL-08:62 | 4065.37 | 0.00 |
| August | 0.00 | 0.00 | 0.472033E+10 | 0.327084E+10 | 6729.98 | 20-AUG-13:12 | 3524.56 | 0.00 |
| September | 0.00 | 0.00 | 0.440057E+10 | 0.310884E+10 | 6671.13 | 18-SEP-08:32 | 3803.91 | 0.00 |
| October | 0.00 | 0.00 | 0.418856E+10 | 0.294740E+10 | 6737.11 | 23-OCT-08:62 | 3526.21 | 0.00 |
| November | 0.00 | 0.00 | 0.381156E+10 | 0.277646E+10 | 6644.91 | 02-NOV-07:42 | 3847.14 | 0.00 |
| December | 0.00 | 0.00 | 0.353730E+10 | 0.267073E+10 | 6711.81 | 20-DEC-08:42 | 3660.62 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.521156E+11 | 0.382138E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.351922E+10 | 0.267073E+10 | 6361.13 | 3524.56 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.540457E+10 | 0.388499E+10 | 6737.11 | 4539.96 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.445790E+10 | 0.360115E+10 | 6553.99 | 08-JAN-08:32 | 4041.36 | 0.00 |
| February | 0.00 | 0.00 | 0.416405E+10 | 0.335353E+10 | 6520.26 | 10-FEB-08:32 | 4143.61 | 0.00 |
| March | 0.00 | 0.00 | 0.461930E+10 | 0.360689E+10 | 6598.37 | 15-MAR-07:22 | 3817.16 | 0.00 |
| April | 0.00 | 0.00 | 0.467422E+10 | 0.343850E+10 | 6303.47 | 14-APR-16:52 | 4543.36 | 0.00 |
| May | 0.00 | 0.00 | 0.503393E+10 | 0.351121E+10 | 6510.68 | 31-MAY-21:42 | 4186.47 | 0.00 |
| June | 0.00 | 0.00 | 0.488789E+10 | 0.341254E+10 | 6568.60 | 27-JUN-07:12 | 3877.75 | 0.00 |
| July | 0.00 | 0.00 | 0.427983E+10 | 0.316541E+10 | 6544.94 | 22-JUL-08:62 | 4013.23 | 0.00 |
| August | 0.00 | 0.00 | 0.454014E+10 | 0.311222E+10 | 6676.24 | 20-AUG-13:12 | 3513.23 | 0.00 |
| September | 0.00 | 0.00 | 0.447540E+10 | 0.317932E+10 | 6615.20 | 18-SEP-08:32 | 3812.74 | 0.00 |
| October | 0.00 | 0.00 | 0.451173E+10 | 0.324503E+10 | 6682.39 | 23-OCT-07:52 | 3534.12 | 0.00 |
| November | 0.00 | 0.00 | 0.442415E+10 | 0.334572E+10 | 6569.98 | 02-NOV-07:32 | 3934.54 | 0.00 |
| December | 0.00 | 0.00 | 0.441758E+10 | 0.348990E+10 | 6609.98 | 24-DEC-08:22 | 3845.43 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.544861E+11 | 0.404614E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.416405E+10 | 0.311222E+10 | 6303.47 | 3513.23 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.503393E+10 | 0.360689E+10 | 6682.39 | 4543.36 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.445788E+10 | 0.360238E+10 | 6533.45 | 08-JAN-08:32 | 4033.00 | 0.00 |
| February | 0.00 | 0.00 | 0.416428E+10 | 0.335495E+10 | 6499.94 | 10-FEB-08:32 | 4134.71 | 0.00 |
| March | 0.00 | 0.00 | 0.461685E+10 | 0.360606E+10 | 6578.16 | 15-MAR-07:22 | 3808.78 | 0.00 |
| April | 0.00 | 0.00 | 0.467303E+10 | 0.343871E+10 | 6284.88 | 14-APR-16:52 | 4530.01 | 0.00 |
| May | 0.00 | 0.00 | 0.503348E+10 | 0.351207E+10 | 6491.71 | 31-MAY-21:42 | 4172.72 | 0.00 |
| June | 0.00 | 0.00 | 0.488791E+10 | 0.341379E+10 | 6548.65 | 27-JUN-07:12 | 3868.98 | 0.00 |
| July | 0.00 | 0.00 | 0.427927E+10 | 0.316612E+10 | 6524.84 | 22-JUL-08:62 | 4003.42 | 0.00 |
| August | 0.00 | 0.00 | 0.454020E+10 | 0.311346E+10 | 6655.18 | 20-AUG-13:12 | 3505.39 | 0.00 |
| September | 0.00 | 0.00 | 0.447545E+10 | 0.318052E+10 | 6594.48 | 18-SEP-08:32 | 3804.54 | 0.00 |
| October | 0.00 | 0.00 | 0.451068E+10 | 0.324529E+10 | 6661.69 | 23-OCT-07:52 | 3525.40 | 0.00 |
| November | 0.00 | 0.00 | 0.442349E+10 | 0.334634E+10 | 6549.27 | 02-NOV-07:32 | 3926.72 | 0.00 |
| December | 0.00 | 0.00 | 0.441739E+10 | 0.349103E+10 | 6589.43 | 24-DEC-08:22 | 3836.64 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.544799E+11 | 0.404707E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.416428E+10 | 0.311346E+10 | 6284.88 | 3505.39 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.503348E+10 | 0.360606E+10 | 6661.69 | 4530.01 | 0.00 |
Report: PlantLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 7537.70 | 14368.66 | 12-JAN-07:50 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 7490.45 | 14335.24 | 01-FEB-07:40 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 7377.34 | 14181.35 | 01-MAR-07:50 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 7223.02 | 13906.26 | 01-APR-06:50 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 7071.46 | 13605.60 | 01-MAY-06:45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 6963.20 | 13343.38 | 01-JUN-06:50 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 6927.92 | 13215.50 | 31-JUL-06:40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 6975.99 | 13380.92 | 31-AUG-06:50 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 7093.04 | 13647.21 | 30-SEP-06:50 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 7247.97 | 13957.66 | 31-OCT-06:50 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 7398.81 | 14211.77 | 30-NOV-07:50 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 7504.92 | 14355.25 | 31-DEC-07:40 |
| Annual Sum or Average | 0.00 | 7232.92 | ||||
| Minimum of Months | 0.00 | 0.00 | 6927.92 | 13215.50 | ||
| Maximum of Months | 0.00 | 0.00 | 7537.70 | 14368.66 |
Report: FanReportMonthly
For: SPLIT GSW SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.316968E+09 | 0.93 | 350.37 | 01-JAN-08:22 | 0.90 |
| February | 0.301160E+09 | 0.95 | 350.37 | 01-FEB-08:22 | 0.91 |
| March | 0.337573E+09 | 1.00 | 350.37 | 02-MAR-07:42 | 0.91 |
| April | 0.338590E+09 | 1.01 | 350.37 | 14-APR-16:52 | 0.91 |
| May | 0.360645E+09 | 1.00 | 350.37 | 10-MAY-21:02 | 0.91 |
| June | 0.354235E+09 | 0.99 | 350.37 | 21-JUN-07:12 | 0.90 |
| July | 0.318479E+09 | 1.00 | 350.37 | 03-JUL-14:22 | 0.91 |
| August | 0.332269E+09 | 1.00 | 350.37 | 04-AUG-13:52 | 0.90 |
| September | 0.324870E+09 | 1.00 | 350.37 | 14-SEP-16:52 | 0.91 |
| October | 0.319737E+09 | 0.99 | 350.37 | 09-OCT-06:32 | 0.90 |
| November | 0.313599E+09 | 0.97 | 350.37 | 02-NOV-07:32 | 0.90 |
| December | 0.314291E+09 | 0.93 | 350.37 | 01-DEC-08:42 | 0.90 |
| Annual Sum or Average | 0.393241E+10 | 0.98 | |||
| Minimum of Months | 0.301160E+09 | 0.93 | 350.37 | 0.90 | |
| Maximum of Months | 0.360645E+09 | 1.01 | 350.37 | 0.91 |
Report: FanReportMonthly
For: G SW APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: G SW APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: SPLIT GNW SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.269908E+09 | 0.92 | 354.11 | 01-JAN-08:22 | 0.90 |
| February | 0.266704E+09 | 0.95 | 354.11 | 01-FEB-09:12 | 0.91 |
| March | 0.322764E+09 | 1.01 | 354.11 | 02-MAR-07:42 | 0.90 |
| April | 0.345039E+09 | 1.01 | 354.11 | 14-APR-16:52 | 0.91 |
| May | 0.380996E+09 | 1.00 | 354.11 | 10-MAY-21:02 | 0.91 |
| June | 0.386843E+09 | 0.99 | 354.11 | 21-JUN-07:12 | 0.90 |
| July | 0.339044E+09 | 1.00 | 354.11 | 03-JUL-14:22 | 0.91 |
| August | 0.345695E+09 | 0.99 | 354.11 | 04-AUG-13:52 | 0.90 |
| September | 0.323971E+09 | 1.00 | 354.11 | 14-SEP-16:52 | 0.91 |
| October | 0.304450E+09 | 0.99 | 354.11 | 09-OCT-06:32 | 0.90 |
| November | 0.281859E+09 | 0.97 | 354.11 | 02-NOV-07:42 | 0.90 |
| December | 0.267622E+09 | 0.93 | 354.11 | 01-DEC-08:42 | 0.90 |
| Annual Sum or Average | 0.383490E+10 | 0.98 | |||
| Minimum of Months | 0.266704E+09 | 0.92 | 354.11 | 0.90 | |
| Maximum of Months | 0.386843E+09 | 1.01 | 354.11 | 0.91 |
Report: FanReportMonthly
For: G NW APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: G NW APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: SPLIT OFFICE SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.109723E+10 | 0.91 | 416.98 | 01-JAN-00:10 | 0.90 |
| February | 0.991164E+09 | 0.91 | 416.98 | 01-FEB-00:10 | 0.90 |
| March | 0.109308E+10 | 0.91 | 416.98 | 01-MAR-00:10 | 0.90 |
| April | 0.106143E+10 | 0.90 | 416.98 | 01-APR-00:10 | 0.90 |
| May | 0.109715E+10 | 0.90 | 416.98 | 01-MAY-00:10 | 0.90 |
| June | 0.106180E+10 | 0.90 | 416.98 | 01-JUN-00:10 | 0.90 |
| July | 0.109475E+10 | 0.90 | 416.98 | 01-JUL-00:10 | 0.90 |
| August | 0.109338E+10 | 0.90 | 416.98 | 01-AUG-00:10 | 0.90 |
| September | 0.106121E+10 | 0.90 | 416.98 | 01-SEP-00:10 | 0.89 |
| October | 0.109441E+10 | 0.90 | 416.98 | 01-OCT-00:10 | 0.89 |
| November | 0.106063E+10 | 0.90 | 416.98 | 01-NOV-00:10 | 0.90 |
| December | 0.109564E+10 | 0.91 | 416.98 | 01-DEC-00:10 | 0.90 |
| Annual Sum or Average | 0.129019E+11 | 0.90 | |||
| Minimum of Months | 0.991164E+09 | 0.90 | 416.98 | 0.89 | |
| Maximum of Months | 0.109723E+10 | 0.91 | 416.98 | 0.90 |
Report: FanReportMonthly
For: SPLIT GNE SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.264720E+09 | 0.92 | 332.50 | 01-JAN-08:22 | 0.90 |
| February | 0.262636E+09 | 0.95 | 332.50 | 01-FEB-09:12 | 0.91 |
| March | 0.316426E+09 | 1.00 | 332.50 | 02-MAR-07:42 | 0.90 |
| April | 0.340048E+09 | 1.00 | 332.50 | 14-APR-16:52 | 0.91 |
| May | 0.376349E+09 | 1.00 | 332.50 | 10-MAY-21:02 | 0.91 |
| June | 0.382303E+09 | 0.99 | 332.50 | 21-JUN-07:12 | 0.90 |
| July | 0.334593E+09 | 1.00 | 332.50 | 03-JUL-14:22 | 0.91 |
| August | 0.342020E+09 | 0.99 | 332.50 | 04-AUG-13:52 | 0.91 |
| September | 0.320793E+09 | 0.99 | 332.50 | 14-SEP-16:52 | 0.91 |
| October | 0.300103E+09 | 0.99 | 332.50 | 09-OCT-06:32 | 0.90 |
| November | 0.278055E+09 | 0.97 | 332.50 | 02-NOV-07:42 | 0.90 |
| December | 0.263005E+09 | 0.92 | 332.50 | 01-DEC-08:42 | 0.90 |
| Annual Sum or Average | 0.378105E+10 | 0.98 | |||
| Minimum of Months | 0.262636E+09 | 0.92 | 332.50 | 0.90 | |
| Maximum of Months | 0.382303E+09 | 1.00 | 332.50 | 0.91 |
Report: FanReportMonthly
For: G NE APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: G NE APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: SPLIT GN1 SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.223944E+09 | 0.92 | 295.48 | 01-JAN-08:22 | 0.90 |
| February | 0.218238E+09 | 0.95 | 295.48 | 01-FEB-09:12 | 0.91 |
| March | 0.259617E+09 | 1.01 | 295.48 | 02-MAR-07:42 | 0.90 |
| April | 0.279611E+09 | 1.01 | 295.48 | 14-APR-16:52 | 0.91 |
| May | 0.316292E+09 | 1.00 | 295.48 | 10-MAY-21:02 | 0.90 |
| June | 0.320759E+09 | 0.99 | 295.48 | 21-JUN-07:12 | 0.90 |
| July | 0.283395E+09 | 1.00 | 295.48 | 03-JUL-14:22 | 0.91 |
| August | 0.287719E+09 | 0.99 | 295.48 | 04-AUG-13:52 | 0.90 |
| September | 0.268662E+09 | 1.00 | 295.48 | 14-SEP-16:52 | 0.91 |
| October | 0.256263E+09 | 0.99 | 295.48 | 09-OCT-06:32 | 0.90 |
| November | 0.237137E+09 | 0.97 | 295.48 | 02-NOV-07:42 | 0.90 |
| December | 0.224317E+09 | 0.92 | 295.48 | 01-DEC-08:42 | 0.90 |
| Annual Sum or Average | 0.317595E+10 | 0.98 | |||
| Minimum of Months | 0.218238E+09 | 0.92 | 295.48 | 0.90 | |
| Maximum of Months | 0.320759E+09 | 1.01 | 295.48 | 0.91 |
Report: FanReportMonthly
For: G N1 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: G N1 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: SPLIT GN2 SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.223955E+09 | 0.92 | 295.05 | 01-JAN-08:22 | 0.90 |
| February | 0.218245E+09 | 0.95 | 295.05 | 01-FEB-09:12 | 0.91 |
| March | 0.259503E+09 | 1.01 | 295.05 | 02-MAR-07:42 | 0.90 |
| April | 0.279543E+09 | 1.01 | 295.05 | 14-APR-16:52 | 0.91 |
| May | 0.316242E+09 | 1.00 | 295.05 | 10-MAY-21:02 | 0.90 |
| June | 0.320715E+09 | 0.99 | 295.05 | 21-JUN-07:12 | 0.90 |
| July | 0.283348E+09 | 1.00 | 295.05 | 03-JUL-14:22 | 0.91 |
| August | 0.287698E+09 | 0.99 | 295.05 | 04-AUG-13:52 | 0.90 |
| September | 0.268658E+09 | 1.00 | 295.05 | 14-SEP-16:52 | 0.91 |
| October | 0.256196E+09 | 0.99 | 295.05 | 09-OCT-06:32 | 0.90 |
| November | 0.237111E+09 | 0.97 | 295.05 | 02-NOV-07:42 | 0.90 |
| December | 0.224312E+09 | 0.92 | 295.05 | 01-DEC-08:42 | 0.90 |
| Annual Sum or Average | 0.317553E+10 | 0.98 | |||
| Minimum of Months | 0.218245E+09 | 0.92 | 295.05 | 0.90 | |
| Maximum of Months | 0.320715E+09 | 1.01 | 295.05 | 0.91 |
Report: FanReportMonthly
For: G N2 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: G N2 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: SPLIT GS1 SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.271194E+09 | 0.93 | 291.96 | 01-JAN-08:22 | 0.90 |
| February | 0.253075E+09 | 0.95 | 291.96 | 01-FEB-08:22 | 0.91 |
| March | 0.275000E+09 | 1.00 | 291.96 | 02-MAR-07:42 | 0.91 |
| April | 0.273559E+09 | 1.01 | 291.96 | 14-APR-16:52 | 0.91 |
| May | 0.296172E+09 | 1.00 | 291.96 | 10-MAY-21:02 | 0.90 |
| June | 0.288252E+09 | 0.99 | 291.96 | 21-JUN-07:12 | 0.90 |
| July | 0.263175E+09 | 1.00 | 291.96 | 03-JUL-14:22 | 0.91 |
| August | 0.274469E+09 | 1.00 | 291.96 | 04-AUG-13:52 | 0.91 |
| September | 0.269795E+09 | 1.00 | 291.96 | 14-SEP-16:52 | 0.91 |
| October | 0.271807E+09 | 0.99 | 291.96 | 09-OCT-06:32 | 0.90 |
| November | 0.269089E+09 | 0.96 | 291.96 | 02-NOV-07:32 | 0.90 |
| December | 0.271146E+09 | 0.92 | 291.96 | 01-DEC-08:42 | 0.90 |
| Annual Sum or Average | 0.327673E+10 | 0.98 | |||
| Minimum of Months | 0.253075E+09 | 0.92 | 291.96 | 0.90 | |
| Maximum of Months | 0.296172E+09 | 1.01 | 291.96 | 0.91 |
Report: FanReportMonthly
For: G S1 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: G S1 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: SPLIT GS2 SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.289792E+09 | 0.92 | 294.99 | 01-JAN-08:22 | 0.90 |
| February | 0.269891E+09 | 0.94 | 294.99 | 01-FEB-08:22 | 0.91 |
| March | 0.293901E+09 | 1.00 | 294.99 | 02-MAR-07:42 | 0.91 |
| April | 0.293450E+09 | 1.00 | 294.99 | 14-APR-16:52 | 0.91 |
| May | 0.316861E+09 | 1.00 | 294.99 | 10-MAY-21:02 | 0.91 |
| June | 0.307791E+09 | 0.99 | 294.99 | 21-JUN-07:12 | 0.90 |
| July | 0.283030E+09 | 1.00 | 294.99 | 03-JUL-14:22 | 0.91 |
| August | 0.293095E+09 | 0.99 | 294.99 | 04-AUG-13:52 | 0.91 |
| September | 0.288799E+09 | 0.99 | 294.99 | 14-SEP-16:52 | 0.91 |
| October | 0.291001E+09 | 0.99 | 294.99 | 09-OCT-06:32 | 0.91 |
| November | 0.287090E+09 | 0.96 | 294.99 | 02-NOV-07:32 | 0.90 |
| December | 0.288256E+09 | 0.92 | 294.99 | 01-DEC-08:42 | 0.90 |
| Annual Sum or Average | 0.350296E+10 | 0.98 | |||
| Minimum of Months | 0.269891E+09 | 0.92 | 294.99 | 0.90 | |
| Maximum of Months | 0.316861E+09 | 1.00 | 294.99 | 0.91 |
Report: FanReportMonthly
For: G S2 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: G S2 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: SPLIT MSW SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.634355E+09 | 0.93 | 773.46 | 01-JAN-08:22 | 0.90 |
| February | 0.601290E+09 | 0.95 | 773.46 | 01-FEB-08:22 | 0.91 |
| March | 0.677441E+09 | 1.01 | 773.46 | 02-MAR-07:42 | 0.90 |
| April | 0.675466E+09 | 1.01 | 773.46 | 14-APR-16:52 | 0.91 |
| May | 0.710414E+09 | 1.01 | 773.46 | 10-MAY-21:02 | 0.90 |
| June | 0.691061E+09 | 1.00 | 773.46 | 21-JUN-07:12 | 0.90 |
| July | 0.609362E+09 | 1.01 | 773.46 | 03-JUL-14:22 | 0.90 |
| August | 0.640789E+09 | 1.00 | 773.46 | 04-AUG-13:52 | 0.90 |
| September | 0.627071E+09 | 1.00 | 773.46 | 14-SEP-16:52 | 0.91 |
| October | 0.630721E+09 | 1.00 | 773.46 | 09-OCT-06:32 | 0.90 |
| November | 0.619151E+09 | 0.97 | 773.46 | 02-NOV-07:32 | 0.90 |
| December | 0.622183E+09 | 0.93 | 773.46 | 01-DEC-08:42 | 0.90 |
| Annual Sum or Average | 0.773930E+10 | 0.98 | |||
| Minimum of Months | 0.601290E+09 | 0.93 | 773.46 | 0.90 | |
| Maximum of Months | 0.710414E+09 | 1.01 | 773.46 | 0.91 |
Report: FanReportMonthly
For: M SW APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.72 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.72 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.72 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.71 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.72 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.72 | 46.34 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.71 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.72 | 46.34 | 0.72 |
Report: FanReportMonthly
For: M SW APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.72 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.72 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.72 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.72 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.72 | 46.34 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.72 | 46.34 | 0.72 |
Report: FanReportMonthly
For: SPLIT MNW SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.529977E+09 | 0.92 | 781.47 | 01-JAN-08:22 | 0.90 |
| February | 0.525236E+09 | 0.94 | 781.47 | 01-FEB-09:12 | 0.91 |
| March | 0.643618E+09 | 1.01 | 781.47 | 02-MAR-07:42 | 0.90 |
| April | 0.686042E+09 | 1.01 | 781.47 | 14-APR-16:52 | 0.91 |
| May | 0.750465E+09 | 1.00 | 781.47 | 10-MAY-21:02 | 0.90 |
| June | 0.757438E+09 | 1.00 | 781.47 | 21-JUN-07:12 | 0.90 |
| July | 0.649592E+09 | 1.00 | 781.47 | 03-JUL-14:22 | 0.90 |
| August | 0.666156E+09 | 1.00 | 781.47 | 04-AUG-13:52 | 0.90 |
| September | 0.621709E+09 | 1.00 | 781.47 | 14-SEP-16:52 | 0.91 |
| October | 0.594925E+09 | 1.00 | 781.47 | 09-OCT-06:32 | 0.90 |
| November | 0.548019E+09 | 0.97 | 781.47 | 02-NOV-07:42 | 0.90 |
| December | 0.518695E+09 | 0.92 | 781.47 | 01-DEC-08:42 | 0.90 |
| Annual Sum or Average | 0.749187E+10 | 0.98 | |||
| Minimum of Months | 0.518695E+09 | 0.92 | 781.47 | 0.90 | |
| Maximum of Months | 0.757438E+09 | 1.01 | 781.47 | 0.91 |
Report: FanReportMonthly
For: M NW APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.72 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.72 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.72 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.72 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.72 | 46.34 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.72 | 46.34 | 0.72 |
Report: FanReportMonthly
For: M NW APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.72 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.72 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.72 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.72 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.72 | 46.34 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.72 | 46.34 | 0.72 |
Report: FanReportMonthly
For: SPLIT MSE SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.620003E+09 | 0.93 | 719.85 | 01-JAN-08:22 | 0.90 |
| February | 0.589861E+09 | 0.95 | 719.85 | 01-FEB-08:22 | 0.91 |
| March | 0.661418E+09 | 1.00 | 719.85 | 02-MAR-07:42 | 0.90 |
| April | 0.663550E+09 | 1.01 | 719.85 | 14-APR-16:52 | 0.91 |
| May | 0.700188E+09 | 1.00 | 719.85 | 10-MAY-21:02 | 0.90 |
| June | 0.682084E+09 | 1.00 | 719.85 | 21-JUN-07:12 | 0.90 |
| July | 0.600147E+09 | 1.00 | 719.85 | 03-JUL-14:22 | 0.90 |
| August | 0.632962E+09 | 1.00 | 719.85 | 04-AUG-13:52 | 0.90 |
| September | 0.619453E+09 | 1.00 | 719.85 | 14-SEP-16:52 | 0.91 |
| October | 0.619700E+09 | 0.99 | 719.85 | 09-OCT-06:32 | 0.90 |
| November | 0.608220E+09 | 0.97 | 719.85 | 02-NOV-07:32 | 0.90 |
| December | 0.609207E+09 | 0.93 | 719.85 | 01-DEC-08:42 | 0.90 |
| Annual Sum or Average | 0.760679E+10 | 0.98 | |||
| Minimum of Months | 0.589861E+09 | 0.93 | 719.85 | 0.90 | |
| Maximum of Months | 0.700188E+09 | 1.01 | 719.85 | 0.91 |
Report: FanReportMonthly
For: M SE APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.72 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.72 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.72 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.71 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.72 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.72 | 46.34 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.71 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.72 | 46.34 | 0.72 |
Report: FanReportMonthly
For: M SE APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.72 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.72 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.72 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.72 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.72 | 46.34 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.72 | 46.34 | 0.72 |
Report: FanReportMonthly
For: SPLIT MNE SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.518228E+09 | 0.92 | 727.87 | 01-JAN-08:22 | 0.90 |
| February | 0.516092E+09 | 0.95 | 727.87 | 01-FEB-09:12 | 0.91 |
| March | 0.629133E+09 | 1.01 | 727.87 | 02-MAR-07:42 | 0.90 |
| April | 0.674751E+09 | 1.01 | 727.87 | 14-APR-16:52 | 0.91 |
| May | 0.740250E+09 | 1.00 | 727.87 | 10-MAY-21:02 | 0.90 |
| June | 0.747809E+09 | 0.99 | 727.87 | 21-JUN-07:12 | 0.90 |
| July | 0.640247E+09 | 1.00 | 727.87 | 03-JUL-14:22 | 0.91 |
| August | 0.658622E+09 | 1.00 | 727.87 | 04-AUG-13:52 | 0.90 |
| September | 0.615043E+09 | 1.00 | 727.87 | 14-SEP-16:52 | 0.91 |
| October | 0.585521E+09 | 1.00 | 727.87 | 09-OCT-06:32 | 0.90 |
| November | 0.539488E+09 | 0.97 | 727.87 | 02-NOV-07:42 | 0.90 |
| December | 0.508596E+09 | 0.93 | 727.87 | 01-DEC-08:42 | 0.90 |
| Annual Sum or Average | 0.737378E+10 | 0.98 | |||
| Minimum of Months | 0.508596E+09 | 0.92 | 727.87 | 0.90 | |
| Maximum of Months | 0.747809E+09 | 1.01 | 727.87 | 0.91 |
Report: FanReportMonthly
For: M NE APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.72 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.72 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.72 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.72 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.72 | 46.34 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.72 | 46.34 | 0.72 |
Report: FanReportMonthly
For: M NE APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.72 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.72 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.72 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.72 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.72 | 46.34 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.72 | 46.34 | 0.72 |
Report: FanReportMonthly
For: SPLIT MN1 SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.433007E+09 | 0.92 | 647.62 | 01-JAN-08:22 | 0.90 |
| February | 0.422149E+09 | 0.95 | 647.62 | 01-FEB-09:12 | 0.91 |
| March | 0.506110E+09 | 1.01 | 647.62 | 02-MAR-07:42 | 0.90 |
| April | 0.544527E+09 | 1.01 | 647.62 | 14-APR-16:52 | 0.91 |
| May | 0.613743E+09 | 1.01 | 647.62 | 10-MAY-21:02 | 0.90 |
| June | 0.620184E+09 | 1.00 | 647.62 | 21-JUN-07:12 | 0.90 |
| July | 0.539615E+09 | 1.00 | 647.62 | 03-JUL-14:22 | 0.90 |
| August | 0.549683E+09 | 1.00 | 647.62 | 04-AUG-13:52 | 0.90 |
| September | 0.511297E+09 | 1.00 | 647.62 | 14-SEP-16:52 | 0.90 |
| October | 0.495247E+09 | 1.00 | 647.62 | 09-OCT-06:32 | 0.90 |
| November | 0.456254E+09 | 0.97 | 647.62 | 02-NOV-07:42 | 0.90 |
| December | 0.430570E+09 | 0.92 | 647.62 | 01-DEC-08:42 | 0.90 |
| Annual Sum or Average | 0.612238E+10 | 0.98 | |||
| Minimum of Months | 0.422149E+09 | 0.92 | 647.62 | 0.90 | |
| Maximum of Months | 0.620184E+09 | 1.01 | 647.62 | 0.91 |
Report: FanReportMonthly
For: M N1 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.72 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.72 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.72 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.71 | 46.34 | 01-MAY-00:10 | 0.71 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.72 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.72 | 46.34 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.71 | 46.34 | 0.71 | |
| Maximum of Months | 0.124124E+09 | 0.72 | 46.34 | 0.72 |
Report: FanReportMonthly
For: M N1 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.72 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.72 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.72 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.72 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.72 | 46.34 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.72 | 46.34 | 0.72 |
Report: FanReportMonthly
For: SPLIT MN2 SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.433122E+09 | 0.92 | 646.63 | 01-JAN-08:22 | 0.90 |
| February | 0.422237E+09 | 0.95 | 646.63 | 01-FEB-09:12 | 0.91 |
| March | 0.505894E+09 | 1.01 | 646.63 | 02-MAR-07:42 | 0.90 |
| April | 0.544400E+09 | 1.01 | 646.63 | 14-APR-16:52 | 0.91 |
| May | 0.613652E+09 | 1.01 | 646.63 | 10-MAY-21:02 | 0.90 |
| June | 0.620115E+09 | 1.00 | 646.63 | 21-JUN-07:12 | 0.90 |
| July | 0.539535E+09 | 1.00 | 646.63 | 03-JUL-14:22 | 0.90 |
| August | 0.549660E+09 | 1.00 | 646.63 | 04-AUG-13:52 | 0.90 |
| September | 0.511298E+09 | 1.00 | 646.63 | 14-SEP-16:52 | 0.90 |
| October | 0.495132E+09 | 1.00 | 646.63 | 09-OCT-06:32 | 0.90 |
| November | 0.456225E+09 | 0.97 | 646.63 | 02-NOV-07:42 | 0.90 |
| December | 0.430645E+09 | 0.92 | 646.63 | 01-DEC-08:42 | 0.90 |
| Annual Sum or Average | 0.612191E+10 | 0.98 | |||
| Minimum of Months | 0.422237E+09 | 0.92 | 646.63 | 0.90 | |
| Maximum of Months | 0.620115E+09 | 1.01 | 646.63 | 0.91 |
Report: FanReportMonthly
For: M N2 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.72 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.72 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.72 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.71 | 46.34 | 01-MAY-00:10 | 0.71 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.72 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.72 | 46.34 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.71 | 46.34 | 0.71 | |
| Maximum of Months | 0.124124E+09 | 0.72 | 46.34 | 0.72 |
Report: FanReportMonthly
For: M N2 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.72 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.72 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.72 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.72 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.72 | 46.34 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.72 | 46.34 | 0.72 |
Report: FanReportMonthly
For: SPLIT MS1 SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.534714E+09 | 0.93 | 639.64 | 01-JAN-08:22 | 0.90 |
| February | 0.496353E+09 | 0.95 | 639.64 | 01-FEB-08:22 | 0.91 |
| March | 0.538678E+09 | 1.01 | 639.64 | 02-MAR-07:42 | 0.90 |
| April | 0.532652E+09 | 1.01 | 639.64 | 14-APR-16:52 | 0.91 |
| May | 0.572099E+09 | 1.01 | 639.64 | 10-MAY-21:02 | 0.90 |
| June | 0.552362E+09 | 1.00 | 639.64 | 21-JUN-07:12 | 0.90 |
| July | 0.498194E+09 | 1.00 | 639.64 | 03-JUL-14:22 | 0.90 |
| August | 0.522813E+09 | 1.00 | 639.64 | 04-AUG-13:52 | 0.90 |
| September | 0.515077E+09 | 1.00 | 639.64 | 14-SEP-16:52 | 0.91 |
| October | 0.529194E+09 | 1.00 | 639.64 | 09-OCT-06:32 | 0.90 |
| November | 0.525194E+09 | 0.97 | 639.64 | 02-NOV-07:32 | 0.90 |
| December | 0.531491E+09 | 0.92 | 639.64 | 01-DEC-08:42 | 0.90 |
| Annual Sum or Average | 0.634882E+10 | 0.98 | |||
| Minimum of Months | 0.496353E+09 | 0.92 | 639.64 | 0.90 | |
| Maximum of Months | 0.572099E+09 | 1.01 | 639.64 | 0.91 |
Report: FanReportMonthly
For: M S1 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.72 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.72 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.72 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.71 | 46.34 | 01-MAY-00:10 | 0.71 |
| June | 0.120120E+09 | 0.71 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.72 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.72 | 46.34 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.71 | 46.34 | 0.71 | |
| Maximum of Months | 0.124124E+09 | 0.72 | 46.34 | 0.72 |
Report: FanReportMonthly
For: M S1 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.72 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.72 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.72 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.72 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.72 | 46.34 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.72 | 46.34 | 0.72 |
Report: FanReportMonthly
For: SPLIT MS2 SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.534675E+09 | 0.93 | 638.64 | 01-JAN-08:22 | 0.90 |
| February | 0.496337E+09 | 0.95 | 638.64 | 01-FEB-08:22 | 0.91 |
| March | 0.538419E+09 | 1.01 | 638.64 | 02-MAR-07:42 | 0.90 |
| April | 0.532505E+09 | 1.01 | 638.64 | 14-APR-16:52 | 0.91 |
| May | 0.572001E+09 | 1.01 | 638.64 | 10-MAY-21:02 | 0.90 |
| June | 0.552302E+09 | 1.00 | 638.64 | 21-JUN-07:12 | 0.90 |
| July | 0.498109E+09 | 1.00 | 638.64 | 03-JUL-14:22 | 0.90 |
| August | 0.522777E+09 | 1.00 | 638.64 | 04-AUG-13:52 | 0.90 |
| September | 0.515049E+09 | 1.00 | 638.64 | 14-SEP-16:52 | 0.91 |
| October | 0.529036E+09 | 1.00 | 638.64 | 09-OCT-06:32 | 0.90 |
| November | 0.525091E+09 | 0.97 | 638.64 | 02-NOV-07:32 | 0.90 |
| December | 0.531424E+09 | 0.92 | 638.64 | 01-DEC-08:42 | 0.90 |
| Annual Sum or Average | 0.634772E+10 | 0.98 | |||
| Minimum of Months | 0.496337E+09 | 0.92 | 638.64 | 0.90 | |
| Maximum of Months | 0.572001E+09 | 1.01 | 638.64 | 0.91 |
Report: FanReportMonthly
For: M S2 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.72 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.72 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.72 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.71 | 46.34 | 01-MAY-00:10 | 0.71 |
| June | 0.120120E+09 | 0.71 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.72 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.72 | 46.34 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.71 | 46.34 | 0.71 | |
| Maximum of Months | 0.124124E+09 | 0.72 | 46.34 | 0.72 |
Report: FanReportMonthly
For: M S2 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.72 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.72 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.72 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.72 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.72 | 46.34 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.72 | 46.34 | 0.72 |
Report: FanReportMonthly
For: SPLIT TSW SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.336218E+09 | 0.93 | 416.24 | 01-JAN-08:22 | 0.90 |
| February | 0.321156E+09 | 0.95 | 416.24 | 01-FEB-08:22 | 0.91 |
| March | 0.368928E+09 | 1.01 | 416.24 | 02-MAR-07:42 | 0.90 |
| April | 0.371785E+09 | 1.01 | 416.24 | 14-APR-16:52 | 0.91 |
| May | 0.388944E+09 | 1.01 | 416.24 | 10-MAY-21:02 | 0.91 |
| June | 0.379261E+09 | 1.00 | 416.24 | 21-JUN-07:12 | 0.90 |
| July | 0.329070E+09 | 1.00 | 416.24 | 03-JUL-14:02 | 0.90 |
| August | 0.345035E+09 | 1.00 | 416.24 | 04-AUG-13:52 | 0.90 |
| September | 0.339034E+09 | 1.00 | 416.24 | 14-SEP-16:52 | 0.91 |
| October | 0.335315E+09 | 1.00 | 416.24 | 09-OCT-06:32 | 0.90 |
| November | 0.327659E+09 | 0.97 | 416.24 | 02-NOV-07:32 | 0.90 |
| December | 0.326882E+09 | 0.93 | 416.24 | 01-DEC-08:42 | 0.90 |
| Annual Sum or Average | 0.416929E+10 | 0.98 | |||
| Minimum of Months | 0.321156E+09 | 0.93 | 416.24 | 0.90 | |
| Maximum of Months | 0.388944E+09 | 1.01 | 416.24 | 0.91 |
Report: FanReportMonthly
For: T SW APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.71 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.71 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.71 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: T SW APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: SPLIT TNW SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.281701E+09 | 0.92 | 422.63 | 01-JAN-08:22 | 0.90 |
| February | 0.281709E+09 | 0.95 | 422.63 | 01-FEB-09:12 | 0.91 |
| March | 0.351675E+09 | 1.01 | 422.63 | 02-MAR-07:42 | 0.90 |
| April | 0.377475E+09 | 1.01 | 422.63 | 14-APR-16:52 | 0.91 |
| May | 0.409918E+09 | 1.00 | 422.63 | 10-MAY-21:02 | 0.91 |
| June | 0.413787E+09 | 1.00 | 422.63 | 21-JUN-07:12 | 0.90 |
| July | 0.349946E+09 | 1.00 | 422.63 | 03-JUL-14:02 | 0.91 |
| August | 0.358198E+09 | 1.00 | 422.63 | 04-AUG-13:52 | 0.90 |
| September | 0.336127E+09 | 1.00 | 422.63 | 14-SEP-16:52 | 0.91 |
| October | 0.316780E+09 | 1.00 | 422.63 | 09-OCT-06:32 | 0.90 |
| November | 0.290559E+09 | 0.97 | 422.63 | 02-NOV-07:42 | 0.90 |
| December | 0.272727E+09 | 0.93 | 422.63 | 01-DEC-08:42 | 0.90 |
| Annual Sum or Average | 0.404060E+10 | 0.98 | |||
| Minimum of Months | 0.272727E+09 | 0.92 | 422.63 | 0.90 | |
| Maximum of Months | 0.413787E+09 | 1.01 | 422.63 | 0.91 |
Report: FanReportMonthly
For: T NW APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: T NW APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: SPLIT TSE SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.327109E+09 | 0.93 | 378.48 | 01-JAN-08:22 | 0.90 |
| February | 0.313803E+09 | 0.95 | 378.48 | 01-FEB-08:22 | 0.91 |
| March | 0.358804E+09 | 1.00 | 378.48 | 02-MAR-07:42 | 0.90 |
| April | 0.363920E+09 | 1.01 | 378.48 | 14-APR-16:52 | 0.91 |
| May | 0.382068E+09 | 1.00 | 378.48 | 10-MAY-21:02 | 0.90 |
| June | 0.373325E+09 | 0.99 | 378.48 | 21-JUN-07:12 | 0.90 |
| July | 0.323239E+09 | 1.00 | 378.48 | 03-JUL-14:02 | 0.91 |
| August | 0.339969E+09 | 1.00 | 378.48 | 04-AUG-13:52 | 0.90 |
| September | 0.333912E+09 | 1.00 | 378.48 | 14-SEP-16:52 | 0.91 |
| October | 0.328511E+09 | 0.99 | 378.48 | 09-OCT-06:32 | 0.90 |
| November | 0.320700E+09 | 0.97 | 378.48 | 02-NOV-07:32 | 0.90 |
| December | 0.318864E+09 | 0.93 | 378.48 | 01-DEC-08:42 | 0.90 |
| Annual Sum or Average | 0.408422E+10 | 0.98 | |||
| Minimum of Months | 0.313803E+09 | 0.93 | 378.48 | 0.90 | |
| Maximum of Months | 0.382068E+09 | 1.01 | 378.48 | 0.91 |
Report: FanReportMonthly
For: T SE APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.71 | 23.17 | 01-MAY-00:10 | 0.71 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.71 | 23.17 | 0.71 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: T SE APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: SPLIT TNE SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.273977E+09 | 0.93 | 384.86 | 01-JAN-08:22 | 0.90 |
| February | 0.275752E+09 | 0.95 | 384.86 | 01-FEB-09:12 | 0.91 |
| March | 0.342596E+09 | 1.01 | 384.86 | 02-MAR-07:42 | 0.90 |
| April | 0.370028E+09 | 1.01 | 384.86 | 14-APR-16:52 | 0.91 |
| May | 0.403046E+09 | 1.00 | 384.86 | 10-MAY-21:02 | 0.91 |
| June | 0.407454E+09 | 0.99 | 384.86 | 21-JUN-07:12 | 0.90 |
| July | 0.344077E+09 | 1.00 | 384.86 | 03-JUL-14:02 | 0.91 |
| August | 0.353321E+09 | 1.00 | 384.86 | 04-AUG-13:52 | 0.90 |
| September | 0.331640E+09 | 1.00 | 384.86 | 14-SEP-16:52 | 0.91 |
| October | 0.311022E+09 | 1.00 | 384.86 | 09-OCT-06:32 | 0.90 |
| November | 0.285151E+09 | 0.97 | 384.86 | 02-NOV-07:42 | 0.90 |
| December | 0.266226E+09 | 0.93 | 384.86 | 01-DEC-08:42 | 0.90 |
| Annual Sum or Average | 0.396429E+10 | 0.98 | |||
| Minimum of Months | 0.266226E+09 | 0.93 | 384.86 | 0.90 | |
| Maximum of Months | 0.407454E+09 | 1.01 | 384.86 | 0.91 |
Report: FanReportMonthly
For: T NE APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.71 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.71 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: T NE APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: SPLIT TN1 SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.233841E+09 | 0.92 | 356.92 | 01-JAN-08:22 | 0.90 |
| February | 0.230779E+09 | 0.95 | 356.92 | 01-FEB-09:12 | 0.91 |
| March | 0.283184E+09 | 1.01 | 356.92 | 02-MAR-07:42 | 0.90 |
| April | 0.307105E+09 | 1.01 | 356.92 | 14-APR-16:52 | 0.91 |
| May | 0.342240E+09 | 1.00 | 356.92 | 10-MAY-21:02 | 0.90 |
| June | 0.346149E+09 | 1.00 | 356.92 | 21-JUN-07:12 | 0.90 |
| July | 0.296327E+09 | 1.00 | 356.92 | 03-JUL-14:02 | 0.91 |
| August | 0.301140E+09 | 1.00 | 356.92 | 04-AUG-13:52 | 0.90 |
| September | 0.282171E+09 | 1.00 | 356.92 | 14-SEP-16:52 | 0.90 |
| October | 0.268593E+09 | 1.00 | 356.92 | 09-OCT-06:32 | 0.90 |
| November | 0.246036E+09 | 0.97 | 356.92 | 02-NOV-07:42 | 0.90 |
| December | 0.229778E+09 | 0.93 | 356.92 | 01-DEC-08:42 | 0.90 |
| Annual Sum or Average | 0.336734E+10 | 0.98 | |||
| Minimum of Months | 0.229778E+09 | 0.92 | 356.92 | 0.90 | |
| Maximum of Months | 0.346149E+09 | 1.01 | 356.92 | 0.91 |
Report: FanReportMonthly
For: T N1 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.71 | 23.17 | 01-MAY-00:10 | 0.71 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.71 | 23.17 | 0.71 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: T N1 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: SPLIT TN2 SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.233811E+09 | 0.92 | 355.55 | 01-JAN-08:22 | 0.90 |
| February | 0.230749E+09 | 0.95 | 355.55 | 01-FEB-09:12 | 0.91 |
| March | 0.282937E+09 | 1.01 | 355.55 | 02-MAR-07:42 | 0.90 |
| April | 0.306900E+09 | 1.01 | 355.55 | 14-APR-16:52 | 0.91 |
| May | 0.342039E+09 | 1.00 | 355.55 | 10-MAY-21:02 | 0.90 |
| June | 0.345966E+09 | 1.00 | 355.55 | 21-JUN-07:12 | 0.90 |
| July | 0.296163E+09 | 1.00 | 355.55 | 03-JUL-14:02 | 0.91 |
| August | 0.301009E+09 | 1.00 | 355.55 | 04-AUG-13:52 | 0.90 |
| September | 0.282056E+09 | 1.00 | 355.55 | 14-SEP-16:52 | 0.90 |
| October | 0.268428E+09 | 1.00 | 355.55 | 09-OCT-06:32 | 0.90 |
| November | 0.245923E+09 | 0.97 | 355.55 | 02-NOV-07:42 | 0.90 |
| December | 0.229736E+09 | 0.93 | 355.55 | 01-DEC-08:42 | 0.90 |
| Annual Sum or Average | 0.336572E+10 | 0.98 | |||
| Minimum of Months | 0.229736E+09 | 0.92 | 355.55 | 0.90 | |
| Maximum of Months | 0.345966E+09 | 1.01 | 355.55 | 0.91 |
Report: FanReportMonthly
For: T N2 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.71 | 23.17 | 01-MAY-00:10 | 0.71 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.71 | 23.17 | 0.71 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: T N2 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: SPLIT TS1 SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.287909E+09 | 0.93 | 350.49 | 01-JAN-08:22 | 0.90 |
| February | 0.269959E+09 | 0.95 | 350.49 | 01-FEB-08:22 | 0.91 |
| March | 0.300206E+09 | 1.01 | 350.49 | 02-MAR-07:42 | 0.90 |
| April | 0.301005E+09 | 1.01 | 350.49 | 14-APR-16:52 | 0.91 |
| May | 0.320644E+09 | 1.01 | 350.49 | 10-MAY-21:02 | 0.90 |
| June | 0.310931E+09 | 1.00 | 350.49 | 21-JUN-07:12 | 0.90 |
| July | 0.274893E+09 | 1.01 | 350.49 | 03-JUL-14:22 | 0.91 |
| August | 0.287426E+09 | 1.00 | 350.49 | 04-AUG-13:52 | 0.90 |
| September | 0.284624E+09 | 1.00 | 350.49 | 14-SEP-16:52 | 0.91 |
| October | 0.286740E+09 | 1.00 | 350.49 | 09-OCT-06:32 | 0.90 |
| November | 0.282701E+09 | 0.97 | 350.49 | 02-NOV-07:32 | 0.90 |
| December | 0.283514E+09 | 0.93 | 350.49 | 01-DEC-08:42 | 0.90 |
| Annual Sum or Average | 0.349055E+10 | 0.99 | |||
| Minimum of Months | 0.269959E+09 | 0.93 | 350.49 | 0.90 | |
| Maximum of Months | 0.320644E+09 | 1.01 | 350.49 | 0.91 |
Report: FanReportMonthly
For: T S1 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.71 | 23.17 | 01-MAY-00:10 | 0.71 |
| June | 60059763.04 | 0.71 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.71 | 23.17 | 0.71 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: T S1 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: SPLIT TS2 SUPPLY FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.287574E+09 | 0.93 | 349.12 | 01-JAN-08:22 | 0.90 |
| February | 0.269663E+09 | 0.95 | 349.12 | 01-FEB-08:22 | 0.91 |
| March | 0.299725E+09 | 1.01 | 349.12 | 02-MAR-07:42 | 0.90 |
| April | 0.300607E+09 | 1.01 | 349.12 | 14-APR-16:52 | 0.91 |
| May | 0.320273E+09 | 1.01 | 349.12 | 10-MAY-21:02 | 0.90 |
| June | 0.310599E+09 | 1.00 | 349.12 | 21-JUN-07:12 | 0.90 |
| July | 0.274566E+09 | 1.01 | 349.12 | 03-JUL-14:22 | 0.91 |
| August | 0.287130E+09 | 1.00 | 349.12 | 04-AUG-13:52 | 0.90 |
| September | 0.284324E+09 | 1.00 | 349.12 | 14-SEP-16:52 | 0.91 |
| October | 0.286368E+09 | 1.00 | 349.12 | 09-OCT-06:32 | 0.90 |
| November | 0.282347E+09 | 0.97 | 349.12 | 02-NOV-07:32 | 0.90 |
| December | 0.283178E+09 | 0.93 | 349.12 | 01-DEC-08:42 | 0.90 |
| Annual Sum or Average | 0.348635E+10 | 0.98 | |||
| Minimum of Months | 0.269663E+09 | 0.93 | 349.12 | 0.90 | |
| Maximum of Months | 0.320273E+09 | 1.01 | 349.12 | 0.91 |
Report: FanReportMonthly
For: T S2 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.71 | 23.17 | 01-MAY-00:10 | 0.71 |
| June | 60059763.04 | 0.71 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.71 | 23.17 | 0.71 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: FanReportMonthly
For: T S2 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.72 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.72 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.72 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.72 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.72 | 23.17 | 01-DEC-00:10 | 0.72 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.72 | 23.17 | 0.72 |
Report: PumpReportMonthly
For: SWHSYS1 PUMP
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
| January | 38818862.27 | 11645658.68 | 14.49 | 01-JAN-00:10 | 4.35 | 4.35 | 56.91 | 0.11 |
| February | 35062198.18 | 10518659.46 | 14.49 | 01-FEB-00:10 | 4.35 | 4.35 | 56.91 | 0.11 |
| March | 38818862.27 | 11645658.68 | 14.49 | 01-MAR-00:10 | 4.35 | 4.35 | 56.94 | 0.11 |
| April | 37566640.91 | 11269992.27 | 14.49 | 01-APR-00:10 | 4.35 | 4.35 | 58.66 | 0.11 |
| May | 38818862.27 | 11645658.68 | 14.49 | 01-MAY-00:10 | 4.35 | 4.35 | 58.70 | 0.11 |
| June | 37566640.91 | 11269992.27 | 14.49 | 01-JUN-00:10 | 4.35 | 4.35 | 58.72 | 0.11 |
| July | 38818862.27 | 11645658.68 | 14.49 | 01-JUL-00:10 | 4.35 | 4.35 | 58.73 | 0.11 |
| August | 38818862.27 | 11645658.68 | 14.49 | 01-AUG-00:10 | 4.35 | 4.35 | 58.74 | 0.11 |
| September | 37566640.91 | 11269992.27 | 14.49 | 01-SEP-00:10 | 4.35 | 4.35 | 58.71 | 0.11 |
| October | 38818862.27 | 11645658.68 | 14.49 | 01-OCT-00:10 | 4.35 | 4.35 | 58.69 | 0.11 |
| November | 37566640.91 | 11269992.27 | 14.49 | 01-NOV-00:10 | 4.35 | 4.35 | 58.67 | 0.11 |
| December | 38818862.27 | 11645658.68 | 14.49 | 01-DEC-00:10 | 4.35 | 4.35 | 56.93 | 0.11 |
| Annual Sum or Average | 0.457061E+09 | 0.137118E+09 | ||||||
| Minimum of Months | 35062198.18 | 10518659.46 | 14.49 | 4.35 | 4.35 | 56.91 | 0.11 | |
| Maximum of Months | 38818862.27 | 11645658.68 | 14.49 | 4.35 | 4.35 | 58.74 | 0.11 |
Report: CondLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| PLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 56.91 | 59.95 | 7537.70 | 14368.66 | 12-JAN-07:50 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 56.91 | 59.95 | 7490.45 | 14335.24 | 01-FEB-07:40 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 56.94 | 59.95 | 7377.34 | 14181.35 | 01-MAR-07:50 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 58.66 | 59.94 | 7223.02 | 13906.26 | 01-APR-06:50 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 58.70 | 59.96 | 7071.46 | 13605.60 | 01-MAY-06:45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 58.72 | 59.95 | 6963.20 | 13343.38 | 01-JUN-06:50 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 58.73 | 59.95 | 6927.92 | 13215.50 | 31-JUL-06:40 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 58.74 | 59.95 | 6975.99 | 13380.92 | 31-AUG-06:50 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 58.71 | 59.94 | 7093.04 | 13647.21 | 30-SEP-06:50 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 58.69 | 59.95 | 7247.97 | 13957.66 | 31-OCT-06:50 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 58.67 | 59.95 | 7398.81 | 14211.77 | 30-NOV-07:50 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 56.93 | 59.95 | 7504.92 | 14355.25 | 31-DEC-07:40 |
| Annual Sum or Average | 0.00 | 7232.92 | ||||||
| Minimum of Months | 0.00 | 0.00 | 56.91 | 59.94 | 6927.92 | 13215.50 | ||
| Maximum of Months | 0.00 | 0.00 | 58.74 | 59.96 | 7537.70 | 14368.66 |
Report: ZoneTemperatureOscillationReportMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GSW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.159357E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.152499E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.171960E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.174176E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.185866E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.182403E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.160799E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.168889E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.164977E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.161195E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.157747E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.157612E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.199748E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.152499E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.185866E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GNW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.135061E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.134377E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.163506E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.176411E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.195090E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.197856E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.170095E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.174638E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.163550E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.152623E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.141047E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.133538E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.193779E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.133538E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.197856E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT OFFICE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.204785E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.192885E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.220016E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.210966E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.231190E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.226963E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.201439E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.219887E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.205166E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.207014E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.201342E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.200578E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.252223E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.192885E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.231190E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GNE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.133799E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.133624E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.161936E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.175624E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.194684E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.197526E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.169553E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.174562E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.163598E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.151983E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.140541E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.132567E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.193000E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.132567E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.197526E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GN1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.114675E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.112526E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.134642E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.146460E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.165872E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.168037E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.145549E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.148824E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.138883E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.131504E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.121460E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.114536E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.164297E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.112526E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.168037E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GN2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.114709E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.112557E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.134617E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.146460E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.165887E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.168055E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.145560E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.148849E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.138915E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.131502E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.121476E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.114561E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.164315E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.112557E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.168055E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GS1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.140269E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.131841E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.144186E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.144966E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.157205E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.152890E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.136792E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.143652E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.141084E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.141062E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.139309E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.139901E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.171316E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.131841E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.157205E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GS2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.149485E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.140220E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.153669E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.155052E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.167697E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.162770E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.146713E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.152985E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.150609E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.150620E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.148237E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.148347E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.182641E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.140220E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.167697E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MSW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.316702E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.302395E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.342677E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.345007E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.363691E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.353547E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.305630E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.323572E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.316293E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.315720E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.309235E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.309879E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.390435E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.302395E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.363691E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MNW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.263649E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.263132E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.324139E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.348689E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.382175E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.385359E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.324114E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.334716E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.312106E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.296453E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.272601E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.257328E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.376446E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.257328E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.385359E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MSE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.313452E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.300315E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.338873E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.343242E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.363074E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.353429E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.304819E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.323771E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.316463E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.314195E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.307625E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.307288E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.388654E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.300315E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.363074E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MNE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.260686E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.261346E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.320434E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.346801E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.381250E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.384759E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.323010E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.334712E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.312246E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.295069E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.271335E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.255165E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.374681E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.255165E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.384759E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MN1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.220181E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.216178E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.260663E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.283255E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.319742E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.322817E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.275288E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.282421E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.262496E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.252307E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.232013E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.218309E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.314567E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.216178E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.322817E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MN2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.220295E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.216276E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.260620E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.283262E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.319775E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.322862E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.275315E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.282481E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.262563E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.252312E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.232056E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.218402E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.314622E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.216276E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.322862E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MS1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.274366E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.256551E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.280180E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.279983E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.301290E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.290725E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.256898E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.271459E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.267184E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.272363E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.269661E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.272051E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.329271E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.256551E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.301290E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MS2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.274425E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.256616E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.280130E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.279989E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.301328E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.290780E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.256928E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.271521E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.267248E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.272362E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.269686E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.272096E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.329311E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.256616E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.301328E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TSW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.167221E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.160921E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.185863E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.188916E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.198131E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.193069E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.164274E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.173417E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.170175E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.167069E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.162920E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.162200E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.209418E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.160921E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.198131E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TNW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.139704E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.140709E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.176504E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.190999E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.207870E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.209636E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.173910E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.179269E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.168035E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.157225E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.143990E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.134896E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.202275E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.134896E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.209636E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TSE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.164927E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.159338E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.183296E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.187489E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.197366E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.192709E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.163590E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.173297E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.169954E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.165979E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.161663E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.160418E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.208002E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.159338E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.197366E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TNE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.137598E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.139409E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.174155E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.189614E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.207020E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.209079E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.173157E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.179132E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.167924E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.156358E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.143092E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.133367E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.200990E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.133367E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.209079E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TN1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.117561E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.116850E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.144144E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.157705E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.176054E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.177909E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.149321E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.152831E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.143065E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.135165E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.123618E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.115197E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.170942E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.115197E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.177909E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TN2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.117611E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.116898E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.144100E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.157687E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.176048E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.177913E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.149320E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.152851E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.143087E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.135158E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.123629E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.115240E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.170954E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.115240E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.177913E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TS1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.145510E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.137452E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.153745E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.155588E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.166079E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.160948E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.139464E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.146827E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.145234E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.145207E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.142864E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.142948E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.178187E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.137452E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.166079E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TS2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.145441E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.137395E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.153608E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.155491E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.166001E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.160886E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.139392E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.146776E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.145179E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.145116E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.142781E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.142877E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.178094E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.137395E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.166001E+10 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GSW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.316968E+09 | 0.489624E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.301160E+09 | 0.463927E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.337573E+09 | 0.519164E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.338590E+09 | 0.525246E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.360645E+09 | 0.565174E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.354235E+09 | 0.555914E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.318479E+09 | 0.495111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.332269E+09 | 0.523417E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.324870E+09 | 0.509718E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.319737E+09 | 0.501737E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.313599E+09 | 0.489585E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.314291E+09 | 0.488334E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.393241E+10 | 0.612695E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.301160E+09 | 0.463927E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.360645E+09 | 0.565174E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GNW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.269908E+09 | 0.412229E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.266704E+09 | 0.406505E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.322764E+09 | 0.492169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.345039E+09 | 0.531256E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.380996E+09 | 0.592936E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.386843E+09 | 0.603373E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.339044E+09 | 0.523516E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.345695E+09 | 0.540678E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.323971E+09 | 0.504341E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.304450E+09 | 0.473823E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.281859E+09 | 0.435931E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.267622E+09 | 0.411290E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.383490E+10 | 0.592805E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.266704E+09 | 0.406505E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.386843E+09 | 0.603373E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT OFFICE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.109723E+10 | 0.376448E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.991164E+09 | 0.367906E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.109308E+10 | 0.430603E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.106143E+10 | 0.409933E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.109715E+10 | 0.481329E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.106180E+10 | 0.477888E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.109475E+10 | 0.371369E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.109338E+10 | 0.446832E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.106121E+10 | 0.399520E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.109441E+10 | 0.397098E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.106063E+10 | 0.384307E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.109564E+10 | 0.362844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.129019E+11 | 0.490608E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.991164E+09 | 0.362844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.109723E+10 | 0.481329E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GNE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.264720E+09 | 0.410509E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.262636E+09 | 0.406508E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.316426E+09 | 0.489716E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.340048E+09 | 0.531625E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.376349E+09 | 0.594990E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.382303E+09 | 0.605849E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.334593E+09 | 0.524686E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.342020E+09 | 0.543245E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.320793E+09 | 0.507125E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.300103E+09 | 0.474137E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.278055E+09 | 0.436612E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.263005E+09 | 0.410416E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.378105E+10 | 0.593542E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.262636E+09 | 0.406508E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.382303E+09 | 0.605849E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GN1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.223944E+09 | 0.353324E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.218238E+09 | 0.343478E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.259617E+09 | 0.408335E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.279611E+09 | 0.444580E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.316292E+09 | 0.508731E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.320759E+09 | 0.516888E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.283395E+09 | 0.452036E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.287719E+09 | 0.465000E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.268662E+09 | 0.432448E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.256263E+09 | 0.412398E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.237137E+09 | 0.379227E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.224317E+09 | 0.356392E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.317595E+10 | 0.507284E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.218238E+09 | 0.343478E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.320759E+09 | 0.516888E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GN2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.223955E+09 | 0.353467E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.218245E+09 | 0.343611E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.259503E+09 | 0.408292E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.279543E+09 | 0.444625E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.316242E+09 | 0.508831E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.320715E+09 | 0.517004E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.283348E+09 | 0.452121E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.287698E+09 | 0.465129E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.268658E+09 | 0.432593E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.256196E+09 | 0.412432E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.237111E+09 | 0.379318E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.224312E+09 | 0.356510E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.317553E+10 | 0.507393E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.218245E+09 | 0.343611E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.320715E+09 | 0.517004E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GS1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.271194E+09 | 0.435184E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.253075E+09 | 0.404789E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.275000E+09 | 0.438680E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.273559E+09 | 0.440822E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.296172E+09 | 0.482646E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.288252E+09 | 0.470303E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.263175E+09 | 0.425227E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.274469E+09 | 0.449519E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.269795E+09 | 0.440263E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.271807E+09 | 0.443590E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.269089E+09 | 0.436832E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.271146E+09 | 0.437981E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.327673E+10 | 0.530583E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.253075E+09 | 0.404789E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.296172E+09 | 0.482646E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GS2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.289792E+09 | 0.464603E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.269891E+09 | 0.431300E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.293901E+09 | 0.468288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.293450E+09 | 0.472108E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.316861E+09 | 0.515369E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.307791E+09 | 0.501229E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.283030E+09 | 0.456570E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.293095E+09 | 0.478990E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.288799E+09 | 0.470381E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.291001E+09 | 0.474037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.287090E+09 | 0.465371E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.288256E+09 | 0.465062E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.350296E+10 | 0.566331E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.269891E+09 | 0.431300E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.316861E+09 | 0.515369E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MSW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.634355E+09 | 0.966162E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.601290E+09 | 0.912978E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.677441E+09 | 0.102775E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.675466E+09 | 0.103365E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.710414E+09 | 0.109853E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.691061E+09 | 0.106994E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.609362E+09 | 0.934197E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.640789E+09 | 0.996730E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.627071E+09 | 0.970527E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.630721E+09 | 0.976591E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.619151E+09 | 0.953132E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.622183E+09 | 0.953131E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.773930E+10 | 0.118933E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.601290E+09 | 0.912978E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.710414E+09 | 0.109853E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MNW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.529977E+09 | 0.799467E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.525236E+09 | 0.790502E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.643618E+09 | 0.969784E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.686042E+09 | 0.104348E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.750465E+09 | 0.115378E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.757438E+09 | 0.116660E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.649592E+09 | 0.990264E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.666156E+09 | 0.103007E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.621709E+09 | 0.956219E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.594925E+09 | 0.915188E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.548019E+09 | 0.837398E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.518695E+09 | 0.787346E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.749187E+10 | 0.114401E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.518695E+09 | 0.787346E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.757438E+09 | 0.116660E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MSE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.620003E+09 | 0.962524E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.589861E+09 | 0.912968E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.661418E+09 | 0.102195E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.663550E+09 | 0.103430E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.700188E+09 | 0.110323E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.682084E+09 | 0.107609E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.600147E+09 | 0.937246E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.632962E+09 | 0.100289E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.619453E+09 | 0.976677E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.619700E+09 | 0.977438E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.608220E+09 | 0.954100E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.609207E+09 | 0.951306E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.760679E+10 | 0.119107E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.589861E+09 | 0.912968E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.700188E+09 | 0.110323E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MNE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.518228E+09 | 0.795107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.516092E+09 | 0.790133E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.629133E+09 | 0.963626E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.674751E+09 | 0.104368E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.740250E+09 | 0.115791E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.747809E+09 | 0.117204E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.640247E+09 | 0.992739E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.658622E+09 | 0.103575E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.615043E+09 | 0.961970E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.585521E+09 | 0.915755E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.539488E+09 | 0.838289E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.508596E+09 | 0.785388E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.737378E+10 | 0.114524E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.508596E+09 | 0.785388E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.747809E+09 | 0.117204E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MN1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.433007E+09 | 0.674060E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.422149E+09 | 0.655459E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.506110E+09 | 0.785788E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.544527E+09 | 0.854461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.613743E+09 | 0.974097E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.620184E+09 | 0.985777E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.539615E+09 | 0.849022E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.549683E+09 | 0.877265E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.511297E+09 | 0.812427E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.495247E+09 | 0.786929E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.456254E+09 | 0.720229E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.430570E+09 | 0.674970E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.612238E+10 | 0.965048E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.422149E+09 | 0.655459E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.620184E+09 | 0.985777E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MN2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.433122E+09 | 0.674484E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.422237E+09 | 0.655831E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.505894E+09 | 0.785713E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.544400E+09 | 0.854556E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.613652E+09 | 0.974300E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.620115E+09 | 0.986025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.539535E+09 | 0.849197E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.549660E+09 | 0.877537E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.511298E+09 | 0.812714E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.495132E+09 | 0.787020E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.456225E+09 | 0.720435E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.430645E+09 | 0.675330E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.612191E+10 | 0.965314E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.422237E+09 | 0.655831E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.620115E+09 | 0.986025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MS1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.534714E+09 | 0.845216E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.496353E+09 | 0.781788E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.538678E+09 | 0.846780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.532652E+09 | 0.846036E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.572099E+09 | 0.919132E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.552362E+09 | 0.888452E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.498194E+09 | 0.793303E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.522813E+09 | 0.844677E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.515077E+09 | 0.828527E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.529194E+09 | 0.851293E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.525194E+09 | 0.839918E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.531491E+09 | 0.845687E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.634882E+10 | 0.101308E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.496353E+09 | 0.781788E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.572099E+09 | 0.919132E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MS2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.534675E+09 | 0.845519E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.496337E+09 | 0.782095E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.538419E+09 | 0.846703E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.532505E+09 | 0.846134E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.572001E+09 | 0.919343E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.552302E+09 | 0.888712E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.498109E+09 | 0.793484E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.522777E+09 | 0.844955E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.515049E+09 | 0.828815E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.529036E+09 | 0.851383E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.525091E+09 | 0.840103E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.531424E+09 | 0.845934E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.634772E+10 | 0.101332E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.496337E+09 | 0.782095E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.572001E+09 | 0.919343E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TSW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.336218E+09 | 0.508891E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.321156E+09 | 0.484546E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.368928E+09 | 0.556187E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.371785E+09 | 0.564793E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.388944E+09 | 0.596808E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.379261E+09 | 0.582794E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.329070E+09 | 0.500680E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.345035E+09 | 0.532840E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.339034E+09 | 0.520736E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.335315E+09 | 0.515451E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.327659E+09 | 0.500823E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.326882E+09 | 0.497484E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.416929E+10 | 0.636203E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.321156E+09 | 0.484546E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.388944E+09 | 0.596808E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TNW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.281701E+09 | 0.421829E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.281709E+09 | 0.420973E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.351675E+09 | 0.526529E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.377475E+09 | 0.570301E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.409918E+09 | 0.625981E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.413787E+09 | 0.633345E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.349946E+09 | 0.529969E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.358198E+09 | 0.550336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.336127E+09 | 0.513225E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.316780E+09 | 0.483780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.290559E+09 | 0.440577E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.272727E+09 | 0.410830E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.404060E+10 | 0.612768E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.272727E+09 | 0.410830E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.413787E+09 | 0.633345E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TSE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.327109E+09 | 0.506327E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.313803E+09 | 0.484222E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.358804E+09 | 0.552467E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.363920E+09 | 0.564762E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.382068E+09 | 0.599196E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.373325E+09 | 0.586354E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.323239E+09 | 0.502406E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.339969E+09 | 0.536358E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.333912E+09 | 0.523999E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.328511E+09 | 0.515881E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.320700E+09 | 0.501041E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.318864E+09 | 0.496382E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.408422E+10 | 0.636939E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.313803E+09 | 0.484222E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.382068E+09 | 0.599196E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TNE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.273977E+09 | 0.418620E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.275752E+09 | 0.420509E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.342596E+09 | 0.522933E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.370028E+09 | 0.570288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.403046E+09 | 0.628340E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.407454E+09 | 0.636848E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.344077E+09 | 0.531678E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.353321E+09 | 0.553875E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.331640E+09 | 0.516564E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.311022E+09 | 0.484336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.285151E+09 | 0.440997E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.266226E+09 | 0.409231E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.396429E+10 | 0.613422E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.266226E+09 | 0.409231E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.407454E+09 | 0.636848E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TN1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.233841E+09 | 0.357288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.230779E+09 | 0.351675E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.283184E+09 | 0.431648E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.307105E+09 | 0.472939E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.342240E+09 | 0.533091E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.346149E+09 | 0.540281E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.296327E+09 | 0.457840E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.301140E+09 | 0.471850E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.282171E+09 | 0.439877E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.268593E+09 | 0.418779E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.246036E+09 | 0.381023E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.229778E+09 | 0.353500E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.336734E+10 | 0.520979E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.229778E+09 | 0.351675E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.346149E+09 | 0.540281E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TN2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.233811E+09 | 0.357541E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.230749E+09 | 0.351922E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.282937E+09 | 0.431609E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.306900E+09 | 0.473006E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.342039E+09 | 0.533225E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.345966E+09 | 0.540457E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.296163E+09 | 0.457964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.301009E+09 | 0.472033E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.282056E+09 | 0.440057E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.268428E+09 | 0.418856E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.245923E+09 | 0.381156E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.229736E+09 | 0.353730E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.336572E+10 | 0.521156E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.229736E+09 | 0.351922E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.345966E+09 | 0.540457E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TS1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.287909E+09 | 0.445790E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.269959E+09 | 0.416405E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.300206E+09 | 0.461930E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.301005E+09 | 0.467422E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.320644E+09 | 0.503393E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.310931E+09 | 0.488789E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.274893E+09 | 0.427983E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.287426E+09 | 0.454014E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.284624E+09 | 0.447540E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.286740E+09 | 0.451173E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.282701E+09 | 0.442415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.283514E+09 | 0.441758E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.349055E+10 | 0.544861E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.269959E+09 | 0.416405E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.320644E+09 | 0.503393E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TS2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.287574E+09 | 0.445788E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.269663E+09 | 0.416428E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.299725E+09 | 0.461685E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.300607E+09 | 0.467303E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.320273E+09 | 0.503348E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.310599E+09 | 0.488791E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.274566E+09 | 0.427927E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.287130E+09 | 0.454020E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.284324E+09 | 0.447545E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.286368E+09 | 0.451068E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.282347E+09 | 0.442349E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.283178E+09 | 0.441739E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.348635E+10 | 0.544799E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.269663E+09 | 0.416428E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.320273E+09 | 0.503348E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GSW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.316968E+09 | 0.00 | 0.00 | 0.00 | 0.127660E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.301160E+09 | 0.00 | 0.00 | 0.00 | 0.122383E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.337573E+09 | 0.00 | 0.00 | 0.00 | 0.138203E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.338590E+09 | 0.00 | 0.00 | 0.00 | 0.140317E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.360645E+09 | 0.00 | 0.00 | 0.00 | 0.149802E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.354235E+09 | 0.00 | 0.00 | 0.00 | 0.146980E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.318479E+09 | 0.00 | 0.00 | 0.00 | 0.128951E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.332269E+09 | 0.00 | 0.00 | 0.00 | 0.135663E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.324870E+09 | 0.00 | 0.00 | 0.00 | 0.132490E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.319737E+09 | 0.00 | 0.00 | 0.00 | 0.129222E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.313599E+09 | 0.00 | 0.00 | 0.00 | 0.126387E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.314291E+09 | 0.00 | 0.00 | 0.00 | 0.126183E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.393241E+10 | 0.00 | 0.00 | 0.00 | 0.160424E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.301160E+09 | 0.00 | 0.00 | 0.00 | 0.122383E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.360645E+09 | 0.00 | 0.00 | 0.00 | 0.149802E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GNW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.269908E+09 | 0.00 | 0.00 | 0.00 | 0.108070E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.266704E+09 | 0.00 | 0.00 | 0.00 | 0.107706E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.322764E+09 | 0.00 | 0.00 | 0.00 | 0.131230E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.345039E+09 | 0.00 | 0.00 | 0.00 | 0.141907E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.380996E+09 | 0.00 | 0.00 | 0.00 | 0.156990E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.386843E+09 | 0.00 | 0.00 | 0.00 | 0.159171E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.339044E+09 | 0.00 | 0.00 | 0.00 | 0.136190E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.345695E+09 | 0.00 | 0.00 | 0.00 | 0.140069E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.323971E+09 | 0.00 | 0.00 | 0.00 | 0.131153E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.304450E+09 | 0.00 | 0.00 | 0.00 | 0.122178E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.281859E+09 | 0.00 | 0.00 | 0.00 | 0.112861E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.267622E+09 | 0.00 | 0.00 | 0.00 | 0.106776E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.383490E+10 | 0.00 | 0.00 | 0.00 | 0.155430E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.266704E+09 | 0.00 | 0.00 | 0.00 | 0.106776E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.386843E+09 | 0.00 | 0.00 | 0.00 | 0.159171E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT OFFICE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.109723E+10 | 0.00 | 0.00 | 0.00 | 0.950619E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.991164E+09 | 0.00 | 0.00 | 0.00 | 0.937686E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.109308E+10 | 0.00 | 0.00 | 0.00 | 0.110708E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.106143E+10 | 0.00 | 0.00 | 0.00 | 0.104822E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.109715E+10 | 0.00 | 0.00 | 0.00 | 0.121475E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.106180E+10 | 0.00 | 0.00 | 0.00 | 0.120783E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.109475E+10 | 0.00 | 0.00 | 0.00 | 0.919640E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.109338E+10 | 0.00 | 0.00 | 0.00 | 0.110550E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.106121E+10 | 0.00 | 0.00 | 0.00 | 0.990447E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.109441E+10 | 0.00 | 0.00 | 0.00 | 0.975728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.106063E+10 | 0.00 | 0.00 | 0.00 | 0.952785E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.109564E+10 | 0.00 | 0.00 | 0.00 | 0.910136E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.129019E+11 | 0.00 | 0.00 | 0.00 | 0.123204E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.991164E+09 | 0.00 | 0.00 | 0.00 | 0.910136E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.109723E+10 | 0.00 | 0.00 | 0.00 | 0.121475E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GNE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.264720E+09 | 0.00 | 0.00 | 0.00 | 0.107327E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.262636E+09 | 0.00 | 0.00 | 0.00 | 0.107361E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.316426E+09 | 0.00 | 0.00 | 0.00 | 0.130293E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.340048E+09 | 0.00 | 0.00 | 0.00 | 0.141620E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.376349E+09 | 0.00 | 0.00 | 0.00 | 0.157049E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.382303E+09 | 0.00 | 0.00 | 0.00 | 0.159296E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.334593E+09 | 0.00 | 0.00 | 0.00 | 0.136094E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.342020E+09 | 0.00 | 0.00 | 0.00 | 0.140360E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.320793E+09 | 0.00 | 0.00 | 0.00 | 0.131519E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.300103E+09 | 0.00 | 0.00 | 0.00 | 0.121973E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.278055E+09 | 0.00 | 0.00 | 0.00 | 0.112735E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.263005E+09 | 0.00 | 0.00 | 0.00 | 0.106267E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.378105E+10 | 0.00 | 0.00 | 0.00 | 0.155189E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.262636E+09 | 0.00 | 0.00 | 0.00 | 0.106267E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.382303E+09 | 0.00 | 0.00 | 0.00 | 0.159296E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GN1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.223944E+09 | 0.00 | 0.00 | 0.00 | 0.922804E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.218238E+09 | 0.00 | 0.00 | 0.00 | 0.907025E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.259617E+09 | 0.00 | 0.00 | 0.00 | 0.108680E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.279611E+09 | 0.00 | 0.00 | 0.00 | 0.118498E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.316292E+09 | 0.00 | 0.00 | 0.00 | 0.134243E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.320759E+09 | 0.00 | 0.00 | 0.00 | 0.135961E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.283395E+09 | 0.00 | 0.00 | 0.00 | 0.117210E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.287719E+09 | 0.00 | 0.00 | 0.00 | 0.120052E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.268662E+09 | 0.00 | 0.00 | 0.00 | 0.112017E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.256263E+09 | 0.00 | 0.00 | 0.00 | 0.105878E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.237137E+09 | 0.00 | 0.00 | 0.00 | 0.977467E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.224317E+09 | 0.00 | 0.00 | 0.00 | 0.921042E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.317595E+10 | 0.00 | 0.00 | 0.00 | 0.132537E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.218238E+09 | 0.00 | 0.00 | 0.00 | 0.907025E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.320759E+09 | 0.00 | 0.00 | 0.00 | 0.135961E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GN2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.223955E+09 | 0.00 | 0.00 | 0.00 | 0.923130E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.218245E+09 | 0.00 | 0.00 | 0.00 | 0.907325E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.259503E+09 | 0.00 | 0.00 | 0.00 | 0.108667E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.279543E+09 | 0.00 | 0.00 | 0.00 | 0.118506E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.316242E+09 | 0.00 | 0.00 | 0.00 | 0.134262E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.320715E+09 | 0.00 | 0.00 | 0.00 | 0.135983E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.283348E+09 | 0.00 | 0.00 | 0.00 | 0.117225E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.287698E+09 | 0.00 | 0.00 | 0.00 | 0.120080E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.268658E+09 | 0.00 | 0.00 | 0.00 | 0.112049E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.256196E+09 | 0.00 | 0.00 | 0.00 | 0.105883E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.237111E+09 | 0.00 | 0.00 | 0.00 | 0.977652E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.224312E+09 | 0.00 | 0.00 | 0.00 | 0.921303E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.317553E+10 | 0.00 | 0.00 | 0.00 | 0.132560E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.218245E+09 | 0.00 | 0.00 | 0.00 | 0.907325E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.320715E+09 | 0.00 | 0.00 | 0.00 | 0.135983E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GS1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.271194E+09 | 0.00 | 0.00 | 0.00 | 0.113150E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.253075E+09 | 0.00 | 0.00 | 0.00 | 0.106533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.275000E+09 | 0.00 | 0.00 | 0.00 | 0.116686E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.273559E+09 | 0.00 | 0.00 | 0.00 | 0.117610E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.296172E+09 | 0.00 | 0.00 | 0.00 | 0.127588E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.288252E+09 | 0.00 | 0.00 | 0.00 | 0.124065E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.263175E+09 | 0.00 | 0.00 | 0.00 | 0.110474E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.274469E+09 | 0.00 | 0.00 | 0.00 | 0.116205E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.269795E+09 | 0.00 | 0.00 | 0.00 | 0.114104E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.271807E+09 | 0.00 | 0.00 | 0.00 | 0.113882E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.269089E+09 | 0.00 | 0.00 | 0.00 | 0.112400E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.271146E+09 | 0.00 | 0.00 | 0.00 | 0.112786E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.327673E+10 | 0.00 | 0.00 | 0.00 | 0.138548E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.253075E+09 | 0.00 | 0.00 | 0.00 | 0.106533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.296172E+09 | 0.00 | 0.00 | 0.00 | 0.127588E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GS2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.289792E+09 | 0.00 | 0.00 | 0.00 | 0.120506E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.269891E+09 | 0.00 | 0.00 | 0.00 | 0.113231E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.293901E+09 | 0.00 | 0.00 | 0.00 | 0.124279E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.293450E+09 | 0.00 | 0.00 | 0.00 | 0.125707E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.316861E+09 | 0.00 | 0.00 | 0.00 | 0.136011E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.307791E+09 | 0.00 | 0.00 | 0.00 | 0.131991E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.283030E+09 | 0.00 | 0.00 | 0.00 | 0.118410E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.293095E+09 | 0.00 | 0.00 | 0.00 | 0.123676E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.288799E+09 | 0.00 | 0.00 | 0.00 | 0.121729E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.291001E+09 | 0.00 | 0.00 | 0.00 | 0.121520E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.287090E+09 | 0.00 | 0.00 | 0.00 | 0.119528E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.288256E+09 | 0.00 | 0.00 | 0.00 | 0.119522E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.350296E+10 | 0.00 | 0.00 | 0.00 | 0.147611E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.269891E+09 | 0.00 | 0.00 | 0.00 | 0.113231E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.316861E+09 | 0.00 | 0.00 | 0.00 | 0.136011E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MSW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.634355E+09 | 0.00 | 0.00 | 0.00 | 0.253266E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.601290E+09 | 0.00 | 0.00 | 0.00 | 0.242266E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.677441E+09 | 0.00 | 0.00 | 0.00 | 0.274933E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.675466E+09 | 0.00 | 0.00 | 0.00 | 0.277460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.710414E+09 | 0.00 | 0.00 | 0.00 | 0.292650E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.691061E+09 | 0.00 | 0.00 | 0.00 | 0.284441E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.609362E+09 | 0.00 | 0.00 | 0.00 | 0.244694E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.640789E+09 | 0.00 | 0.00 | 0.00 | 0.259493E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.627071E+09 | 0.00 | 0.00 | 0.00 | 0.253586E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.630721E+09 | 0.00 | 0.00 | 0.00 | 0.252647E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.619151E+09 | 0.00 | 0.00 | 0.00 | 0.247320E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.622183E+09 | 0.00 | 0.00 | 0.00 | 0.247660E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.773930E+10 | 0.00 | 0.00 | 0.00 | 0.313042E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.601290E+09 | 0.00 | 0.00 | 0.00 | 0.242266E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.710414E+09 | 0.00 | 0.00 | 0.00 | 0.292650E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MNW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.529977E+09 | 0.00 | 0.00 | 0.00 | 0.210651E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.525236E+09 | 0.00 | 0.00 | 0.00 | 0.210609E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.643618E+09 | 0.00 | 0.00 | 0.00 | 0.259777E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.686042E+09 | 0.00 | 0.00 | 0.00 | 0.280085E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.750465E+09 | 0.00 | 0.00 | 0.00 | 0.307129E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.757438E+09 | 0.00 | 0.00 | 0.00 | 0.309615E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.649592E+09 | 0.00 | 0.00 | 0.00 | 0.259155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.666156E+09 | 0.00 | 0.00 | 0.00 | 0.268100E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.621709E+09 | 0.00 | 0.00 | 0.00 | 0.249935E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.594925E+09 | 0.00 | 0.00 | 0.00 | 0.236961E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.548019E+09 | 0.00 | 0.00 | 0.00 | 0.217799E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.518695E+09 | 0.00 | 0.00 | 0.00 | 0.205458E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.749187E+10 | 0.00 | 0.00 | 0.00 | 0.301528E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.518695E+09 | 0.00 | 0.00 | 0.00 | 0.205458E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.757438E+09 | 0.00 | 0.00 | 0.00 | 0.309615E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MSE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.620003E+09 | 0.00 | 0.00 | 0.00 | 0.251452E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.589861E+09 | 0.00 | 0.00 | 0.00 | 0.241328E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.661418E+09 | 0.00 | 0.00 | 0.00 | 0.272731E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.663550E+09 | 0.00 | 0.00 | 0.00 | 0.276887E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.700188E+09 | 0.00 | 0.00 | 0.00 | 0.293055E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.682084E+09 | 0.00 | 0.00 | 0.00 | 0.285221E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.600147E+09 | 0.00 | 0.00 | 0.00 | 0.244804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.632962E+09 | 0.00 | 0.00 | 0.00 | 0.260475E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.619453E+09 | 0.00 | 0.00 | 0.00 | 0.254518E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.619700E+09 | 0.00 | 0.00 | 0.00 | 0.252225E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.608220E+09 | 0.00 | 0.00 | 0.00 | 0.246803E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.609207E+09 | 0.00 | 0.00 | 0.00 | 0.246368E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.760679E+10 | 0.00 | 0.00 | 0.00 | 0.312587E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.589861E+09 | 0.00 | 0.00 | 0.00 | 0.241328E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.700188E+09 | 0.00 | 0.00 | 0.00 | 0.293055E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MNE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.518228E+09 | 0.00 | 0.00 | 0.00 | 0.208863E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.516092E+09 | 0.00 | 0.00 | 0.00 | 0.209736E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.629133E+09 | 0.00 | 0.00 | 0.00 | 0.257521E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.674751E+09 | 0.00 | 0.00 | 0.00 | 0.279325E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.740250E+09 | 0.00 | 0.00 | 0.00 | 0.307225E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.747809E+09 | 0.00 | 0.00 | 0.00 | 0.309978E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.640247E+09 | 0.00 | 0.00 | 0.00 | 0.258985E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.658622E+09 | 0.00 | 0.00 | 0.00 | 0.268850E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.615043E+09 | 0.00 | 0.00 | 0.00 | 0.250741E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.585521E+09 | 0.00 | 0.00 | 0.00 | 0.236517E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.539488E+09 | 0.00 | 0.00 | 0.00 | 0.217387E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.508596E+09 | 0.00 | 0.00 | 0.00 | 0.204305E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.737378E+10 | 0.00 | 0.00 | 0.00 | 0.300943E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.508596E+09 | 0.00 | 0.00 | 0.00 | 0.204305E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.747809E+09 | 0.00 | 0.00 | 0.00 | 0.309978E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MN1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.433007E+09 | 0.00 | 0.00 | 0.00 | 0.176881E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.422149E+09 | 0.00 | 0.00 | 0.00 | 0.173963E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.506110E+09 | 0.00 | 0.00 | 0.00 | 0.210052E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.544527E+09 | 0.00 | 0.00 | 0.00 | 0.228803E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.613743E+09 | 0.00 | 0.00 | 0.00 | 0.258368E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.620184E+09 | 0.00 | 0.00 | 0.00 | 0.260799E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.539615E+09 | 0.00 | 0.00 | 0.00 | 0.221326E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.549683E+09 | 0.00 | 0.00 | 0.00 | 0.227453E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.511297E+09 | 0.00 | 0.00 | 0.00 | 0.211366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.495247E+09 | 0.00 | 0.00 | 0.00 | 0.202782E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.456254E+09 | 0.00 | 0.00 | 0.00 | 0.186388E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.430570E+09 | 0.00 | 0.00 | 0.00 | 0.175252E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.612238E+10 | 0.00 | 0.00 | 0.00 | 0.253343E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.422149E+09 | 0.00 | 0.00 | 0.00 | 0.173963E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.620184E+09 | 0.00 | 0.00 | 0.00 | 0.260799E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MN2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.433122E+09 | 0.00 | 0.00 | 0.00 | 0.176983E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.422237E+09 | 0.00 | 0.00 | 0.00 | 0.174052E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.505894E+09 | 0.00 | 0.00 | 0.00 | 0.210031E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.544400E+09 | 0.00 | 0.00 | 0.00 | 0.228822E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.613652E+09 | 0.00 | 0.00 | 0.00 | 0.258410E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.620115E+09 | 0.00 | 0.00 | 0.00 | 0.260850E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.539535E+09 | 0.00 | 0.00 | 0.00 | 0.221361E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.549660E+09 | 0.00 | 0.00 | 0.00 | 0.227515E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.511298E+09 | 0.00 | 0.00 | 0.00 | 0.211433E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.495132E+09 | 0.00 | 0.00 | 0.00 | 0.202799E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.456225E+09 | 0.00 | 0.00 | 0.00 | 0.186433E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.430645E+09 | 0.00 | 0.00 | 0.00 | 0.175337E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.612191E+10 | 0.00 | 0.00 | 0.00 | 0.253403E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.422237E+09 | 0.00 | 0.00 | 0.00 | 0.174052E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.620115E+09 | 0.00 | 0.00 | 0.00 | 0.260850E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MS1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.534714E+09 | 0.00 | 0.00 | 0.00 | 0.220894E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.496353E+09 | 0.00 | 0.00 | 0.00 | 0.206916E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.538678E+09 | 0.00 | 0.00 | 0.00 | 0.226312E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.532652E+09 | 0.00 | 0.00 | 0.00 | 0.226718E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.572099E+09 | 0.00 | 0.00 | 0.00 | 0.244081E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.552362E+09 | 0.00 | 0.00 | 0.00 | 0.235489E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.498194E+09 | 0.00 | 0.00 | 0.00 | 0.207078E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.522813E+09 | 0.00 | 0.00 | 0.00 | 0.219178E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.515077E+09 | 0.00 | 0.00 | 0.00 | 0.215676E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.529194E+09 | 0.00 | 0.00 | 0.00 | 0.219444E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.525194E+09 | 0.00 | 0.00 | 0.00 | 0.217142E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.531491E+09 | 0.00 | 0.00 | 0.00 | 0.218902E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.634882E+10 | 0.00 | 0.00 | 0.00 | 0.265783E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.496353E+09 | 0.00 | 0.00 | 0.00 | 0.206916E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.572099E+09 | 0.00 | 0.00 | 0.00 | 0.244081E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MS2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.534675E+09 | 0.00 | 0.00 | 0.00 | 0.220957E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.496337E+09 | 0.00 | 0.00 | 0.00 | 0.206982E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.538419E+09 | 0.00 | 0.00 | 0.00 | 0.226288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.532505E+09 | 0.00 | 0.00 | 0.00 | 0.226739E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.572001E+09 | 0.00 | 0.00 | 0.00 | 0.244128E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.552302E+09 | 0.00 | 0.00 | 0.00 | 0.235549E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.498109E+09 | 0.00 | 0.00 | 0.00 | 0.207118E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.522777E+09 | 0.00 | 0.00 | 0.00 | 0.219244E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.515049E+09 | 0.00 | 0.00 | 0.00 | 0.215743E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.529036E+09 | 0.00 | 0.00 | 0.00 | 0.219459E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.525091E+09 | 0.00 | 0.00 | 0.00 | 0.217177E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.531424E+09 | 0.00 | 0.00 | 0.00 | 0.218954E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.634772E+10 | 0.00 | 0.00 | 0.00 | 0.265834E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.496337E+09 | 0.00 | 0.00 | 0.00 | 0.206982E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.572001E+09 | 0.00 | 0.00 | 0.00 | 0.244128E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TSW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.336218E+09 | 0.00 | 0.00 | 0.00 | 0.133599E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.321156E+09 | 0.00 | 0.00 | 0.00 | 0.128806E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.368928E+09 | 0.00 | 0.00 | 0.00 | 0.148970E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.371785E+09 | 0.00 | 0.00 | 0.00 | 0.151737E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.388944E+09 | 0.00 | 0.00 | 0.00 | 0.159237E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.379261E+09 | 0.00 | 0.00 | 0.00 | 0.155142E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.329070E+09 | 0.00 | 0.00 | 0.00 | 0.131367E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.345035E+09 | 0.00 | 0.00 | 0.00 | 0.138913E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.339034E+09 | 0.00 | 0.00 | 0.00 | 0.136271E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.335315E+09 | 0.00 | 0.00 | 0.00 | 0.133538E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.327659E+09 | 0.00 | 0.00 | 0.00 | 0.130154E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.326882E+09 | 0.00 | 0.00 | 0.00 | 0.129512E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.416929E+10 | 0.00 | 0.00 | 0.00 | 0.167725E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.321156E+09 | 0.00 | 0.00 | 0.00 | 0.128806E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.388944E+09 | 0.00 | 0.00 | 0.00 | 0.159237E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TNW
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.281701E+09 | 0.00 | 0.00 | 0.00 | 0.111534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.281709E+09 | 0.00 | 0.00 | 0.00 | 0.112538E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.351675E+09 | 0.00 | 0.00 | 0.00 | 0.141336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.377475E+09 | 0.00 | 0.00 | 0.00 | 0.153251E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.409918E+09 | 0.00 | 0.00 | 0.00 | 0.166878E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.413787E+09 | 0.00 | 0.00 | 0.00 | 0.168257E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.349946E+09 | 0.00 | 0.00 | 0.00 | 0.138915E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.358198E+09 | 0.00 | 0.00 | 0.00 | 0.143450E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.336127E+09 | 0.00 | 0.00 | 0.00 | 0.134423E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.316780E+09 | 0.00 | 0.00 | 0.00 | 0.125547E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.290559E+09 | 0.00 | 0.00 | 0.00 | 0.114934E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.272727E+09 | 0.00 | 0.00 | 0.00 | 0.107623E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.404060E+10 | 0.00 | 0.00 | 0.00 | 0.161869E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.272727E+09 | 0.00 | 0.00 | 0.00 | 0.107623E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.413787E+09 | 0.00 | 0.00 | 0.00 | 0.168257E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TSE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.327109E+09 | 0.00 | 0.00 | 0.00 | 0.132216E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.313803E+09 | 0.00 | 0.00 | 0.00 | 0.127958E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.358804E+09 | 0.00 | 0.00 | 0.00 | 0.147415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.363920E+09 | 0.00 | 0.00 | 0.00 | 0.151097E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.382068E+09 | 0.00 | 0.00 | 0.00 | 0.159159E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.373325E+09 | 0.00 | 0.00 | 0.00 | 0.155376E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.323239E+09 | 0.00 | 0.00 | 0.00 | 0.131266E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.339969E+09 | 0.00 | 0.00 | 0.00 | 0.139300E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.333912E+09 | 0.00 | 0.00 | 0.00 | 0.136563E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.328511E+09 | 0.00 | 0.00 | 0.00 | 0.133128E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.320700E+09 | 0.00 | 0.00 | 0.00 | 0.129593E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.318864E+09 | 0.00 | 0.00 | 0.00 | 0.128532E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.408422E+10 | 0.00 | 0.00 | 0.00 | 0.167160E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.313803E+09 | 0.00 | 0.00 | 0.00 | 0.127958E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.382068E+09 | 0.00 | 0.00 | 0.00 | 0.159159E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TNE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.273977E+09 | 0.00 | 0.00 | 0.00 | 0.110200E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.275752E+09 | 0.00 | 0.00 | 0.00 | 0.111833E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.342596E+09 | 0.00 | 0.00 | 0.00 | 0.139896E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.370028E+09 | 0.00 | 0.00 | 0.00 | 0.152612E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.403046E+09 | 0.00 | 0.00 | 0.00 | 0.166715E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.407454E+09 | 0.00 | 0.00 | 0.00 | 0.168333E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.344077E+09 | 0.00 | 0.00 | 0.00 | 0.138749E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.353321E+09 | 0.00 | 0.00 | 0.00 | 0.143800E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.331640E+09 | 0.00 | 0.00 | 0.00 | 0.134760E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.311022E+09 | 0.00 | 0.00 | 0.00 | 0.125256E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.285151E+09 | 0.00 | 0.00 | 0.00 | 0.114577E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.266226E+09 | 0.00 | 0.00 | 0.00 | 0.106744E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.396429E+10 | 0.00 | 0.00 | 0.00 | 0.161347E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.266226E+09 | 0.00 | 0.00 | 0.00 | 0.106744E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.407454E+09 | 0.00 | 0.00 | 0.00 | 0.168333E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TN1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.233841E+09 | 0.00 | 0.00 | 0.00 | 0.941774E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.230779E+09 | 0.00 | 0.00 | 0.00 | 0.937722E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.283184E+09 | 0.00 | 0.00 | 0.00 | 0.115826E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.307105E+09 | 0.00 | 0.00 | 0.00 | 0.126994E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.342240E+09 | 0.00 | 0.00 | 0.00 | 0.141830E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.346149E+09 | 0.00 | 0.00 | 0.00 | 0.143294E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.296327E+09 | 0.00 | 0.00 | 0.00 | 0.119689E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.301140E+09 | 0.00 | 0.00 | 0.00 | 0.122717E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.282171E+09 | 0.00 | 0.00 | 0.00 | 0.114848E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.268593E+09 | 0.00 | 0.00 | 0.00 | 0.108306E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.246036E+09 | 0.00 | 0.00 | 0.00 | 0.990141E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.229778E+09 | 0.00 | 0.00 | 0.00 | 0.922191E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.336734E+10 | 0.00 | 0.00 | 0.00 | 0.137269E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.229778E+09 | 0.00 | 0.00 | 0.00 | 0.922191E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.346149E+09 | 0.00 | 0.00 | 0.00 | 0.143294E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TN2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.233811E+09 | 0.00 | 0.00 | 0.00 | 0.942301E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.230749E+09 | 0.00 | 0.00 | 0.00 | 0.938229E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.282937E+09 | 0.00 | 0.00 | 0.00 | 0.115806E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.306900E+09 | 0.00 | 0.00 | 0.00 | 0.126997E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.342039E+09 | 0.00 | 0.00 | 0.00 | 0.141844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.345966E+09 | 0.00 | 0.00 | 0.00 | 0.143317E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.296163E+09 | 0.00 | 0.00 | 0.00 | 0.119704E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.301009E+09 | 0.00 | 0.00 | 0.00 | 0.122750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.282056E+09 | 0.00 | 0.00 | 0.00 | 0.114881E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.268428E+09 | 0.00 | 0.00 | 0.00 | 0.108315E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.245923E+09 | 0.00 | 0.00 | 0.00 | 0.990364E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.229736E+09 | 0.00 | 0.00 | 0.00 | 0.922665E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.336572E+10 | 0.00 | 0.00 | 0.00 | 0.137297E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.229736E+09 | 0.00 | 0.00 | 0.00 | 0.922665E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.345966E+09 | 0.00 | 0.00 | 0.00 | 0.143317E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TS1
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.287909E+09 | 0.00 | 0.00 | 0.00 | 0.116719E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.269959E+09 | 0.00 | 0.00 | 0.00 | 0.110456E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.300206E+09 | 0.00 | 0.00 | 0.00 | 0.123724E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.301005E+09 | 0.00 | 0.00 | 0.00 | 0.125488E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.320644E+09 | 0.00 | 0.00 | 0.00 | 0.134015E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.310931E+09 | 0.00 | 0.00 | 0.00 | 0.129855E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.274893E+09 | 0.00 | 0.00 | 0.00 | 0.111974E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.287426E+09 | 0.00 | 0.00 | 0.00 | 0.118085E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.284624E+09 | 0.00 | 0.00 | 0.00 | 0.116771E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.286740E+09 | 0.00 | 0.00 | 0.00 | 0.116533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.282701E+09 | 0.00 | 0.00 | 0.00 | 0.114594E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.283514E+09 | 0.00 | 0.00 | 0.00 | 0.114597E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.349055E+10 | 0.00 | 0.00 | 0.00 | 0.143281E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.269959E+09 | 0.00 | 0.00 | 0.00 | 0.110456E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.320644E+09 | 0.00 | 0.00 | 0.00 | 0.134015E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TS2
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.287574E+09 | 0.00 | 0.00 | 0.00 | 0.116683E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.269663E+09 | 0.00 | 0.00 | 0.00 | 0.110429E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.299725E+09 | 0.00 | 0.00 | 0.00 | 0.123635E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.300607E+09 | 0.00 | 0.00 | 0.00 | 0.125430E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.320273E+09 | 0.00 | 0.00 | 0.00 | 0.133974E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.310599E+09 | 0.00 | 0.00 | 0.00 | 0.129827E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.274566E+09 | 0.00 | 0.00 | 0.00 | 0.111935E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.287130E+09 | 0.00 | 0.00 | 0.00 | 0.118063E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.284324E+09 | 0.00 | 0.00 | 0.00 | 0.116746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.286368E+09 | 0.00 | 0.00 | 0.00 | 0.116479E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.282347E+09 | 0.00 | 0.00 | 0.00 | 0.114546E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.283178E+09 | 0.00 | 0.00 | 0.00 | 0.114559E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.348635E+10 | 0.00 | 0.00 | 0.00 | 0.143231E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.269663E+09 | 0.00 | 0.00 | 0.00 | 0.110429E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.320273E+09 | 0.00 | 0.00 | 0.00 | 0.133974E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 267333.86 | 0.765139E+09 | 0.00 | 0.00 | 27605831.03 | 0.00 | 0.00 | 0.00 | 0.36 |
| February | 0.00 | 0.768802E+09 | 0.00 | 1272.29 | 22916940.80 | 0.00 | 27449.42 | 0.00 | 0.36 |
| March | 0.00 | 0.975020E+09 | 0.00 | 0.00 | 4317402.18 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.121888E+10 | 0.00 | 0.00 | 980379.27 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.146271E+10 | 0.00 | 0.00 | 2823075.64 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.141568E+10 | 0.00 | 0.00 | 7037961.12 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.108002E+10 | 0.00 | 0.00 | 8959134.31 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.133353E+10 | 0.00 | 0.00 | 7446865.70 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.125613E+10 | 0.00 | 0.00 | 7939865.50 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.120094E+10 | 0.00 | 0.00 | 11945220.66 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.101843E+10 | 0.00 | 0.00 | 20792165.80 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 0.00 | 0.824312E+09 | 0.00 | 15449.49 | 34703642.89 | 0.00 | 31499.95 | 0.00 | 0.36 |
| Annual Sum or Average | 267333.86 | 0.133196E+11 | 0.00 | 16721.79 | 0.157468E+09 | 0.00 | 58949.36 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.765139E+09 | 0.00 | 0.00 | 980379.27 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 267333.86 | 0.146271E+10 | 0.00 | 15449.49 | 34703642.89 | 0.00 | 31499.95 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 273282.79 | 0.726580E+09 | 0.00 | 0.00 | 28986150.22 | 0.00 | 0.00 | 0.00 | 0.36 |
| February | 0.00 | 0.742547E+09 | 0.00 | 2676.89 | 23240320.45 | 0.00 | 38462.39 | 0.00 | 0.36 |
| March | 0.00 | 0.962598E+09 | 0.00 | 0.00 | 4387287.57 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.122402E+10 | 0.00 | 0.00 | 972533.53 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.148088E+10 | 0.00 | 0.00 | 2898789.58 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.144489E+10 | 0.00 | 0.00 | 6889456.60 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.109936E+10 | 0.00 | 0.00 | 7979370.93 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.134613E+10 | 0.00 | 0.00 | 7397862.20 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.125435E+10 | 0.00 | 0.00 | 7785658.02 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.118283E+10 | 0.00 | 0.00 | 12416463.03 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.986847E+09 | 0.00 | 0.00 | 21577493.64 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 29543.55 | 0.784439E+09 | 0.00 | 26174.29 | 34752255.41 | 0.00 | 123460.36 | 0.00 | 0.36 |
| Annual Sum or Average | 302826.35 | 0.132355E+11 | 0.00 | 28851.18 | 0.159284E+09 | 0.00 | 161922.75 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.726580E+09 | 0.00 | 0.00 | 972533.53 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 273282.79 | 0.148088E+10 | 0.00 | 26174.29 | 34752255.41 | 0.00 | 123460.36 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.247641E+09 | 0.642582E+09 | 0.00 | 948405.57 | 0.115647E+09 | 0.00 | 2735178.12 | 0.00 | 0.52 |
| February | 0.153644E+09 | 0.667046E+09 | 0.00 | 1181124.62 | 0.124363E+09 | 0.00 | 2604396.75 | 0.00 | 0.52 |
| March | 94677438.30 | 0.866978E+09 | 0.00 | 512411.56 | 0.177661E+09 | 0.00 | 109253.11 | 0.00 | 0.52 |
| April | 63743238.12 | 0.972395E+09 | 0.00 | 230745.64 | 0.277457E+09 | 0.00 | 0.00 | 0.00 | 0.53 |
| May | 72467029.35 | 0.129192E+10 | 0.00 | 287864.84 | 0.355603E+09 | 0.00 | 80277.16 | 0.00 | 0.53 |
| June | 90638652.85 | 0.130971E+10 | 0.00 | 358583.19 | 0.306575E+09 | 0.00 | 0.00 | 0.00 | 0.53 |
| July | 0.116287E+09 | 0.785953E+09 | 0.00 | 538178.70 | 0.180355E+09 | 0.00 | 1149233.51 | 0.00 | 0.53 |
| August | 0.126148E+09 | 0.118233E+10 | 0.00 | 406945.24 | 0.262871E+09 | 0.00 | 0.00 | 0.00 | 0.53 |
| September | 0.118974E+09 | 0.100868E+10 | 0.00 | 438011.94 | 0.241379E+09 | 0.00 | 489308.07 | 0.00 | 0.53 |
| October | 0.148292E+09 | 0.963842E+09 | 0.00 | 450718.19 | 0.203024E+09 | 0.00 | 474331.96 | 0.00 | 0.53 |
| November | 0.194511E+09 | 0.836638E+09 | 0.00 | 514616.95 | 0.166417E+09 | 0.00 | 861853.46 | 0.00 | 0.53 |
| December | 0.268394E+09 | 0.646899E+09 | 0.00 | 932672.60 | 0.124299E+09 | 0.00 | 1262460.83 | 0.00 | 0.52 |
| Annual Sum or Average | 0.169542E+10 | 0.111750E+11 | 0.00 | 6800279.04 | 0.253565E+10 | 0.00 | 9766292.97 | 0.00 | 0.53 |
| Minimum of Months | 63743238.12 | 0.642582E+09 | 0.00 | 230745.64 | 0.115647E+09 | 0.00 | 0.00 | 0.00 | 0.52 |
| Maximum of Months | 0.268394E+09 | 0.130971E+10 | 0.00 | 1181124.62 | 0.355603E+09 | 0.00 | 2735178.12 | 0.00 | 0.53 |
Report: MechanicalVentilationLoadsMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 331853.65 | 0.727848E+09 | 0.00 | 0.00 | 29256275.27 | 0.00 | 0.00 | 0.00 | 0.36 |
| February | 56.01 | 0.744625E+09 | 0.00 | 2614.55 | 22794511.56 | 0.00 | 42591.15 | 0.00 | 0.36 |
| March | 0.00 | 0.962691E+09 | 0.00 | 0.00 | 4152342.99 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.122551E+10 | 0.00 | 0.00 | 1120017.18 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.148296E+10 | 0.00 | 0.00 | 2897533.56 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.144749E+10 | 0.00 | 0.00 | 6857240.04 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.110122E+10 | 0.00 | 0.00 | 7829113.75 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.134887E+10 | 0.00 | 0.00 | 7491133.11 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.125709E+10 | 0.00 | 0.00 | 7840677.11 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.118417E+10 | 0.00 | 0.00 | 12183093.19 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.988936E+09 | 0.00 | 0.00 | 20894483.21 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 5618.40 | 0.785959E+09 | 0.00 | 27580.89 | 34613784.34 | 0.00 | 109439.12 | 0.00 | 0.36 |
| Annual Sum or Average | 337528.05 | 0.132574E+11 | 0.00 | 30195.44 | 0.157930E+09 | 0.00 | 152030.26 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.727848E+09 | 0.00 | 0.00 | 1120017.18 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 331853.65 | 0.148296E+10 | 0.00 | 27580.89 | 34613784.34 | 0.00 | 109439.12 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 261036.25 | 0.706709E+09 | 0.00 | 0.00 | 31196865.86 | 0.00 | 0.00 | 0.00 | 0.36 |
| February | 165.44 | 0.721684E+09 | 0.00 | 2378.57 | 24241316.43 | 0.00 | 47642.70 | 0.00 | 0.36 |
| March | 0.00 | 0.936545E+09 | 0.00 | 0.00 | 4860227.24 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.119077E+10 | 0.00 | 0.00 | 1321776.43 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.145088E+10 | 0.00 | 0.00 | 3078330.06 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.141573E+10 | 0.00 | 0.00 | 7096532.93 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.107464E+10 | 0.00 | 0.00 | 8070292.98 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.131629E+10 | 0.00 | 0.00 | 7486204.09 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.122045E+10 | 0.00 | 0.00 | 8015219.88 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.115311E+10 | 0.00 | 0.00 | 12923246.43 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.961718E+09 | 0.00 | 0.00 | 22310895.32 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 58715.01 | 0.761824E+09 | 0.00 | 26373.28 | 37991173.09 | 0.00 | 82611.60 | 0.00 | 0.36 |
| Annual Sum or Average | 319916.71 | 0.129103E+11 | 0.00 | 28751.85 | 0.168592E+09 | 0.00 | 130254.31 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.706709E+09 | 0.00 | 0.00 | 1321776.43 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 261036.25 | 0.145088E+10 | 0.00 | 26373.28 | 37991173.09 | 0.00 | 82611.60 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 261655.94 | 0.706938E+09 | 0.00 | 0.00 | 31185821.79 | 0.00 | 0.00 | 0.00 | 0.36 |
| February | 178.85 | 0.721898E+09 | 0.00 | 2376.38 | 24216307.94 | 0.00 | 47726.21 | 0.00 | 0.36 |
| March | 0.00 | 0.936604E+09 | 0.00 | 0.00 | 4860344.25 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.119091E+10 | 0.00 | 0.00 | 1322090.90 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.145105E+10 | 0.00 | 0.00 | 3077769.62 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.141593E+10 | 0.00 | 0.00 | 7097154.89 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.107480E+10 | 0.00 | 0.00 | 8067941.45 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.131651E+10 | 0.00 | 0.00 | 7489323.05 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.122070E+10 | 0.00 | 0.00 | 7996929.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.115327E+10 | 0.00 | 0.00 | 12894616.90 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.961890E+09 | 0.00 | 0.00 | 22314244.49 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 58763.45 | 0.762108E+09 | 0.00 | 26514.62 | 37893200.36 | 0.00 | 82086.64 | 0.00 | 0.36 |
| Annual Sum or Average | 320598.24 | 0.129126E+11 | 0.00 | 28891.01 | 0.168416E+09 | 0.00 | 129812.85 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.706938E+09 | 0.00 | 0.00 | 1322090.90 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 261655.94 | 0.145105E+10 | 0.00 | 26514.62 | 37893200.36 | 0.00 | 82086.64 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 247471.32 | 0.766576E+09 | 0.00 | 0.00 | 29029871.36 | 0.00 | 0.00 | 0.00 | 0.36 |
| February | 0.00 | 0.766440E+09 | 0.00 | 925.17 | 23522372.38 | 0.00 | 26683.70 | 0.00 | 0.36 |
| March | 0.00 | 0.965304E+09 | 0.00 | 0.00 | 4613869.18 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.119567E+10 | 0.00 | 0.00 | 1345061.75 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.143892E+10 | 0.00 | 0.00 | 2845741.62 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.138848E+10 | 0.00 | 0.00 | 7218905.47 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.106154E+10 | 0.00 | 0.00 | 9333722.46 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.131129E+10 | 0.00 | 0.00 | 7517360.05 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.123416E+10 | 0.00 | 0.00 | 8325343.35 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.118832E+10 | 0.00 | 0.00 | 11975649.63 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.101295E+10 | 0.00 | 0.00 | 21291270.68 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 0.00 | 0.824942E+09 | 0.00 | 10973.08 | 35949001.89 | 0.00 | 24353.30 | 0.00 | 0.36 |
| Annual Sum or Average | 247471.32 | 0.131546E+11 | 0.00 | 11898.25 | 0.162968E+09 | 0.00 | 51037.00 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.766440E+09 | 0.00 | 0.00 | 1345061.75 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 247471.32 | 0.143892E+10 | 0.00 | 10973.08 | 35949001.89 | 0.00 | 26683.70 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 233235.10 | 0.782908E+09 | 0.00 | 0.00 | 30273603.40 | 0.00 | 0.00 | 0.00 | 0.36 |
| February | 0.00 | 0.781021E+09 | 0.00 | 1005.77 | 24387151.76 | 0.00 | 22911.50 | 0.00 | 0.36 |
| March | 0.00 | 0.984892E+09 | 0.00 | 0.00 | 4480174.52 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.122036E+10 | 0.00 | 0.00 | 1265035.53 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.146740E+10 | 0.00 | 0.00 | 2717594.20 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.141477E+10 | 0.00 | 0.00 | 7352306.16 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.108644E+10 | 0.00 | 0.00 | 8891498.22 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.133798E+10 | 0.00 | 0.00 | 7978079.45 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.125983E+10 | 0.00 | 0.00 | 8229162.11 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.121388E+10 | 0.00 | 0.00 | 12366727.23 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.103309E+10 | 0.00 | 0.00 | 22047269.44 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 0.00 | 0.841080E+09 | 0.00 | 8577.23 | 37130868.56 | 0.00 | 14122.54 | 0.00 | 0.36 |
| Annual Sum or Average | 233235.10 | 0.134236E+11 | 0.00 | 9582.99 | 0.167119E+09 | 0.00 | 37034.03 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.781021E+09 | 0.00 | 0.00 | 1265035.53 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 233235.10 | 0.146740E+10 | 0.00 | 8577.23 | 37130868.56 | 0.00 | 22911.50 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 579252.12 | 0.149654E+10 | 0.00 | 0.00 | 51709498.33 | 0.00 | 0.00 | 0.00 | 0.36 |
| February | 0.00 | 0.150377E+10 | 0.00 | 5401.05 | 46132873.96 | 0.00 | 79441.24 | 0.00 | 0.36 |
| March | 0.00 | 0.190557E+10 | 0.00 | 0.00 | 8709878.90 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.238854E+10 | 0.00 | 0.00 | 2569276.39 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.285353E+10 | 0.00 | 0.00 | 4955989.37 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.275481E+10 | 0.00 | 0.00 | 14545511.33 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.209146E+10 | 0.00 | 0.00 | 16693014.31 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.257760E+10 | 0.00 | 0.00 | 13611055.99 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.244114E+10 | 0.00 | 0.00 | 15074665.53 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.234531E+10 | 0.00 | 0.00 | 23351024.14 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.199108E+10 | 0.00 | 0.00 | 40735385.23 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 25316.95 | 0.160648E+10 | 0.00 | 62462.61 | 66282240.07 | 0.00 | 183982.99 | 0.00 | 0.36 |
| Annual Sum or Average | 604569.08 | 0.259558E+11 | 0.00 | 67863.66 | 0.304370E+09 | 0.00 | 263424.23 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.149654E+10 | 0.00 | 0.00 | 2569276.39 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 579252.12 | 0.285353E+10 | 0.00 | 62462.61 | 66282240.07 | 0.00 | 183982.99 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 693192.53 | 0.140856E+10 | 0.00 | 0.00 | 57411808.53 | 0.00 | 0.00 | 0.00 | 0.36 |
| February | 1989.66 | 0.144394E+10 | 0.00 | 4760.35 | 47603247.77 | 0.00 | 117555.58 | 0.00 | 0.36 |
| March | 0.00 | 0.187576E+10 | 0.00 | 0.00 | 8579768.99 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.239479E+10 | 0.00 | 0.00 | 2352850.59 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.288747E+10 | 0.00 | 0.00 | 5651388.49 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.281429E+10 | 0.00 | 0.00 | 14481434.01 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.212772E+10 | 0.00 | 0.00 | 16203947.50 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.260027E+10 | 0.00 | 0.00 | 13770161.19 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.243109E+10 | 0.00 | 0.00 | 15011260.24 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.230170E+10 | 0.00 | 0.00 | 23842636.97 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.191899E+10 | 0.00 | 0.00 | 40973684.06 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 185119.48 | 0.151454E+10 | 0.00 | 50464.79 | 68769804.21 | 0.00 | 420305.13 | 0.00 | 0.36 |
| Annual Sum or Average | 880301.66 | 0.257191E+11 | 0.00 | 55225.15 | 0.314652E+09 | 0.00 | 537860.71 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.140856E+10 | 0.00 | 0.00 | 2352850.59 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 693192.53 | 0.288747E+10 | 0.00 | 50464.79 | 68769804.21 | 0.00 | 420305.13 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 730102.92 | 0.150079E+10 | 0.00 | 0.00 | 50016307.54 | 0.00 | 0.00 | 0.00 | 0.36 |
| February | 4218.03 | 0.150988E+10 | 0.00 | 5566.03 | 42944517.48 | 0.00 | 89617.45 | 0.00 | 0.36 |
| March | 0.00 | 0.190576E+10 | 0.00 | 0.00 | 8434117.46 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.239303E+10 | 0.00 | 0.00 | 2544749.39 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.285896E+10 | 0.00 | 0.00 | 5326839.16 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.276309E+10 | 0.00 | 0.00 | 13583737.33 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.209629E+10 | 0.00 | 0.00 | 16614365.41 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.258507E+10 | 0.00 | 0.00 | 13587161.40 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.244818E+10 | 0.00 | 0.00 | 14896233.42 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.234786E+10 | 0.00 | 0.00 | 23495769.36 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.199643E+10 | 0.00 | 0.00 | 37780815.33 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 2537.87 | 0.161214E+10 | 0.00 | 50820.41 | 62904710.69 | 0.00 | 96927.39 | 0.00 | 0.36 |
| Annual Sum or Average | 736858.83 | 0.260175E+11 | 0.00 | 56386.44 | 0.292129E+09 | 0.00 | 186544.83 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.150079E+10 | 0.00 | 0.00 | 2544749.39 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 730102.92 | 0.285896E+10 | 0.00 | 50820.41 | 62904710.69 | 0.00 | 96927.39 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 824260.91 | 0.141256E+10 | 0.00 | 0.00 | 52233072.08 | 0.00 | 0.00 | 0.00 | 0.36 |
| February | 34362.21 | 0.144789E+10 | 0.00 | 4606.20 | 43600706.13 | 0.00 | 131911.46 | 0.00 | 0.36 |
| March | 0.00 | 0.187206E+10 | 0.00 | 0.00 | 8272726.19 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.239476E+10 | 0.00 | 0.00 | 2512527.76 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.288897E+10 | 0.00 | 0.00 | 5114894.71 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.281780E+10 | 0.00 | 0.00 | 13221912.10 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.212772E+10 | 0.00 | 0.00 | 16225640.43 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.260374E+10 | 0.00 | 0.00 | 13495508.22 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.243426E+10 | 0.00 | 0.00 | 15059583.10 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.230092E+10 | 0.00 | 0.00 | 23712760.89 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.191931E+10 | 0.00 | 0.00 | 39931435.05 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 135085.15 | 0.151786E+10 | 0.00 | 66220.64 | 63803373.47 | 0.00 | 388224.49 | 0.00 | 0.36 |
| Annual Sum or Average | 993708.27 | 0.257378E+11 | 0.00 | 70826.84 | 0.297184E+09 | 0.00 | 520135.95 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.141256E+10 | 0.00 | 0.00 | 2512527.76 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 824260.91 | 0.288897E+10 | 0.00 | 66220.64 | 63803373.47 | 0.00 | 388224.49 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 649391.80 | 0.136528E+10 | 0.00 | 0.00 | 57778055.01 | 0.00 | 0.00 | 0.00 | 0.36 |
| February | 24965.03 | 0.139643E+10 | 0.00 | 4252.19 | 46515967.56 | 0.00 | 138512.41 | 0.00 | 0.36 |
| March | 0.00 | 0.181487E+10 | 0.00 | 0.00 | 8541307.31 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.231744E+10 | 0.00 | 0.00 | 2640499.57 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.282102E+10 | 0.00 | 0.00 | 5523098.47 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.275023E+10 | 0.00 | 0.00 | 14551730.81 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.207388E+10 | 0.00 | 0.00 | 15633827.66 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.253876E+10 | 0.00 | 0.00 | 14448323.49 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.235884E+10 | 0.00 | 0.00 | 14362390.71 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.223744E+10 | 0.00 | 0.00 | 24170405.21 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.186215E+10 | 0.00 | 0.00 | 41800698.48 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 172368.32 | 0.147046E+10 | 0.00 | 51921.30 | 69197747.48 | 0.00 | 400843.56 | 0.00 | 0.36 |
| Annual Sum or Average | 846725.14 | 0.250068E+11 | 0.00 | 56173.49 | 0.315164E+09 | 0.00 | 539355.97 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.136528E+10 | 0.00 | 0.00 | 2640499.57 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 649391.80 | 0.282102E+10 | 0.00 | 51921.30 | 69197747.48 | 0.00 | 400843.56 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 651214.18 | 0.136581E+10 | 0.00 | 0.00 | 57780273.17 | 0.00 | 0.00 | 0.00 | 0.36 |
| February | 25655.23 | 0.139689E+10 | 0.00 | 4245.75 | 46479268.98 | 0.00 | 138867.32 | 0.00 | 0.36 |
| March | 0.00 | 0.181495E+10 | 0.00 | 0.00 | 8540735.20 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.231770E+10 | 0.00 | 0.00 | 2641018.66 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.282134E+10 | 0.00 | 0.00 | 5522119.19 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.275060E+10 | 0.00 | 0.00 | 14552384.96 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.207422E+10 | 0.00 | 0.00 | 15635219.86 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.253920E+10 | 0.00 | 0.00 | 14454222.23 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.235921E+10 | 0.00 | 0.00 | 14437698.07 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.223769E+10 | 0.00 | 0.00 | 24174580.91 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.186251E+10 | 0.00 | 0.00 | 41821364.61 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 172627.50 | 0.147095E+10 | 0.00 | 52301.42 | 69183440.66 | 0.00 | 398424.78 | 0.00 | 0.36 |
| Annual Sum or Average | 849496.92 | 0.250111E+11 | 0.00 | 56547.18 | 0.315222E+09 | 0.00 | 537292.10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.136581E+10 | 0.00 | 0.00 | 2641018.66 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 651214.18 | 0.282134E+10 | 0.00 | 52301.42 | 69183440.66 | 0.00 | 398424.78 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 527728.74 | 0.148600E+10 | 0.00 | 0.00 | 54423059.68 | 0.00 | 0.00 | 0.00 | 0.36 |
| February | 42.03 | 0.148459E+10 | 0.00 | 4930.29 | 47585586.59 | 0.00 | 81961.08 | 0.00 | 0.36 |
| March | 0.00 | 0.187062E+10 | 0.00 | 0.00 | 8807839.91 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.232459E+10 | 0.00 | 0.00 | 2691543.03 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.278982E+10 | 0.00 | 0.00 | 6221354.28 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.268642E+10 | 0.00 | 0.00 | 14445585.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.204169E+10 | 0.00 | 0.00 | 17511962.54 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.252286E+10 | 0.00 | 0.00 | 15066679.59 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.238627E+10 | 0.00 | 0.00 | 14468374.15 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.230746E+10 | 0.00 | 0.00 | 23816635.21 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.196769E+10 | 0.00 | 0.00 | 41232374.60 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 19121.16 | 0.159617E+10 | 0.00 | 58341.81 | 69079597.76 | 0.00 | 155710.62 | 0.00 | 0.36 |
| Annual Sum or Average | 546891.93 | 0.254642E+11 | 0.00 | 63272.10 | 0.315351E+09 | 0.00 | 237671.70 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.148459E+10 | 0.00 | 0.00 | 2691543.03 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 527728.74 | 0.278982E+10 | 0.00 | 58341.81 | 69079597.76 | 0.00 | 155710.62 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 529163.19 | 0.148650E+10 | 0.00 | 0.00 | 54315717.04 | 0.00 | 0.00 | 0.00 | 0.36 |
| February | 50.58 | 0.148510E+10 | 0.00 | 4923.71 | 47453148.14 | 0.00 | 82212.87 | 0.00 | 0.36 |
| March | 0.00 | 0.187074E+10 | 0.00 | 0.00 | 8807763.19 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.232489E+10 | 0.00 | 0.00 | 2692166.08 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.279022E+10 | 0.00 | 0.00 | 6219732.16 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.268688E+10 | 0.00 | 0.00 | 14446192.58 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.204209E+10 | 0.00 | 0.00 | 17513159.55 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.252336E+10 | 0.00 | 0.00 | 15073082.08 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.238676E+10 | 0.00 | 0.00 | 14470468.38 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.230768E+10 | 0.00 | 0.00 | 23879300.72 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.196802E+10 | 0.00 | 0.00 | 41235568.13 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 15566.05 | 0.159668E+10 | 0.00 | 53302.02 | 69031697.79 | 0.00 | 137927.48 | 0.00 | 0.36 |
| Annual Sum or Average | 544779.83 | 0.254689E+11 | 0.00 | 58225.73 | 0.315138E+09 | 0.00 | 220140.35 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.148510E+10 | 0.00 | 0.00 | 2692166.08 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 529163.19 | 0.279022E+10 | 0.00 | 53302.02 | 69031697.79 | 0.00 | 137927.48 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 751896.96 | 0.733150E+09 | 0.00 | 4226.37 | 20250376.32 | 0.00 | 30828.19 | 0.00 | 0.36 |
| February | 81119.44 | 0.738626E+09 | 0.00 | 3968.89 | 18484058.23 | 0.00 | 85494.19 | 0.00 | 0.36 |
| March | 0.00 | 0.937432E+09 | 0.00 | 144.92 | 3693875.56 | 0.00 | 1656.48 | 0.00 | 0.36 |
| April | 0.00 | 0.118997E+10 | 0.00 | 0.00 | 1049047.48 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.142032E+10 | 0.00 | 0.00 | 2685487.15 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.137452E+10 | 0.00 | 0.00 | 6841591.82 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.103823E+10 | 0.00 | 0.00 | 8271609.54 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.127727E+10 | 0.00 | 0.00 | 6241999.66 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.121528E+10 | 0.00 | 0.00 | 7149540.78 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.115903E+10 | 0.00 | 0.00 | 10541945.63 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.980879E+09 | 0.00 | 0.00 | 17672408.03 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 85013.43 | 0.785767E+09 | 0.00 | 36911.65 | 25404175.04 | 0.00 | 166370.20 | 0.00 | 0.36 |
| Annual Sum or Average | 918029.83 | 0.128505E+11 | 0.00 | 45251.83 | 0.128286E+09 | 0.00 | 284349.06 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.733150E+09 | 0.00 | 0.00 | 1049047.48 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 751896.96 | 0.142032E+10 | 0.00 | 36911.65 | 25404175.04 | 0.00 | 166370.20 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 887974.31 | 0.695003E+09 | 0.00 | 4634.20 | 22637001.29 | 0.00 | 63310.90 | 0.00 | 0.36 |
| February | 101912.71 | 0.713014E+09 | 0.00 | 1859.65 | 19467761.07 | 0.00 | 89126.67 | 0.00 | 0.36 |
| March | 1836.13 | 0.925547E+09 | 0.00 | 0.00 | 3642216.28 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.119318E+10 | 0.00 | 0.00 | 981972.59 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.143539E+10 | 0.00 | 0.00 | 2763351.75 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.140060E+10 | 0.00 | 0.00 | 6409850.32 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.105505E+10 | 0.00 | 0.00 | 7512303.38 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.128764E+10 | 0.00 | 0.00 | 6241754.12 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.121176E+10 | 0.00 | 0.00 | 6878925.50 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.114083E+10 | 0.00 | 0.00 | 11010203.75 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.949551E+09 | 0.00 | 0.00 | 18488326.29 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 254203.02 | 0.745776E+09 | 0.00 | 30249.70 | 26681465.76 | 0.00 | 293862.60 | 0.00 | 0.36 |
| Annual Sum or Average | 1245926.17 | 0.127533E+11 | 0.00 | 36743.55 | 0.132715E+09 | 0.00 | 446300.17 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.695003E+09 | 0.00 | 0.00 | 981972.59 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 887974.31 | 0.143539E+10 | 0.00 | 30249.70 | 26681465.76 | 0.00 | 293862.60 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 952985.99 | 0.734009E+09 | 0.00 | 6938.07 | 19544146.44 | 0.00 | 44735.67 | 0.00 | 0.36 |
| February | 153366.54 | 0.740514E+09 | 0.00 | 8355.74 | 17275845.45 | 0.00 | 84202.61 | 0.00 | 0.36 |
| March | 0.00 | 0.937419E+09 | 0.00 | 0.00 | 3397484.40 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.119169E+10 | 0.00 | 0.00 | 1070845.37 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.142291E+10 | 0.00 | 0.00 | 2407080.76 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.137837E+10 | 0.00 | 0.00 | 6286222.41 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.104087E+10 | 0.00 | 0.00 | 7559817.82 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.128040E+10 | 0.00 | 0.00 | 6274520.75 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.121808E+10 | 0.00 | 0.00 | 7011089.76 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.116044E+10 | 0.00 | 0.00 | 10017928.08 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.981945E+09 | 0.00 | 0.00 | 16795993.66 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 120202.72 | 0.786484E+09 | 0.00 | 39116.79 | 24566774.85 | 0.00 | 85343.46 | 0.00 | 0.36 |
| Annual Sum or Average | 1226555.25 | 0.128731E+11 | 0.00 | 54410.59 | 0.122208E+09 | 0.00 | 214281.74 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.734009E+09 | 0.00 | 0.00 | 1070845.37 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 952985.99 | 0.142291E+10 | 0.00 | 39116.79 | 24566774.85 | 0.00 | 85343.46 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 1134618.30 | 0.697342E+09 | 0.00 | 7107.63 | 20574987.30 | 0.00 | 90807.28 | 0.00 | 0.36 |
| February | 235613.64 | 0.716072E+09 | 0.00 | 7008.78 | 17774696.18 | 0.00 | 96823.13 | 0.00 | 0.36 |
| March | 0.00 | 0.925817E+09 | 0.00 | 182.80 | 3441254.70 | 0.00 | 531.90 | 0.00 | 0.36 |
| April | 0.00 | 0.119482E+10 | 0.00 | 0.00 | 1004916.99 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.143741E+10 | 0.00 | 0.00 | 2592287.54 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.140346E+10 | 0.00 | 0.00 | 6132580.27 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.105706E+10 | 0.00 | 0.00 | 7107053.57 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.129053E+10 | 0.00 | 0.00 | 6255588.53 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.121469E+10 | 0.00 | 0.00 | 6709924.58 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.114236E+10 | 0.00 | 0.00 | 10793450.17 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.951740E+09 | 0.00 | 0.00 | 17214030.52 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 198394.89 | 0.748234E+09 | 0.00 | 36809.88 | 24239815.30 | 0.00 | 313746.39 | 0.00 | 0.36 |
| Annual Sum or Average | 1568626.83 | 0.127795E+11 | 0.00 | 51109.08 | 0.123841E+09 | 0.00 | 501908.71 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.697342E+09 | 0.00 | 0.00 | 1004916.99 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 1134618.30 | 0.143741E+10 | 0.00 | 36809.88 | 24239815.30 | 0.00 | 313746.39 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 708628.58 | 0.679718E+09 | 0.00 | 3061.75 | 24106059.05 | 0.00 | 15560.22 | 0.00 | 0.36 |
| February | 112638.86 | 0.696191E+09 | 0.00 | 2058.79 | 19870254.52 | 0.00 | 90729.25 | 0.00 | 0.36 |
| March | 0.00 | 0.907066E+09 | 0.00 | 0.00 | 3805464.43 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.116754E+10 | 0.00 | 0.00 | 1116350.62 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.141539E+10 | 0.00 | 0.00 | 2855203.08 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.138139E+10 | 0.00 | 0.00 | 6215135.18 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.103675E+10 | 0.00 | 0.00 | 7710444.68 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.127017E+10 | 0.00 | 0.00 | 6359814.13 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.118723E+10 | 0.00 | 0.00 | 6702358.23 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.111984E+10 | 0.00 | 0.00 | 11350562.13 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.930284E+09 | 0.00 | 0.00 | 18595168.58 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 212041.45 | 0.730193E+09 | 0.00 | 31401.88 | 28791850.66 | 0.00 | 204108.36 | 0.00 | 0.36 |
| Annual Sum or Average | 1033308.89 | 0.125218E+11 | 0.00 | 36522.43 | 0.137479E+09 | 0.00 | 310397.83 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.679718E+09 | 0.00 | 0.00 | 1116350.62 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 708628.58 | 0.141539E+10 | 0.00 | 31401.88 | 28791850.66 | 0.00 | 204108.36 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 716000.47 | 0.680346E+09 | 0.00 | 3004.06 | 23873438.28 | 0.00 | 15716.33 | 0.00 | 0.36 |
| February | 115719.25 | 0.696774E+09 | 0.00 | 2160.53 | 19646564.56 | 0.00 | 91076.59 | 0.00 | 0.36 |
| March | 0.00 | 0.907231E+09 | 0.00 | 0.00 | 3804767.52 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.116778E+10 | 0.00 | 0.00 | 1116459.95 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.141569E+10 | 0.00 | 0.00 | 2854132.71 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.138170E+10 | 0.00 | 0.00 | 6214251.86 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.103706E+10 | 0.00 | 0.00 | 7710797.19 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.127052E+10 | 0.00 | 0.00 | 6363559.27 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.118758E+10 | 0.00 | 0.00 | 6701504.62 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.112021E+10 | 0.00 | 0.00 | 11255873.01 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.930567E+09 | 0.00 | 0.00 | 18603411.77 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 201650.78 | 0.730773E+09 | 0.00 | 31458.59 | 28547077.06 | 0.00 | 212549.21 | 0.00 | 0.36 |
| Annual Sum or Average | 1033370.49 | 0.125262E+11 | 0.00 | 36623.19 | 0.136692E+09 | 0.00 | 319342.13 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.680346E+09 | 0.00 | 0.00 | 1116459.95 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 716000.47 | 0.141569E+10 | 0.00 | 31458.59 | 28547077.06 | 0.00 | 212549.21 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 601848.43 | 0.726482E+09 | 0.00 | 2053.79 | 21234698.58 | 0.00 | 6761.21 | 0.00 | 0.36 |
| February | 81248.45 | 0.728649E+09 | 0.00 | 4017.05 | 18639195.67 | 0.00 | 83826.76 | 0.00 | 0.36 |
| March | 0.00 | 0.923102E+09 | 0.00 | 0.00 | 3823269.40 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.116406E+10 | 0.00 | 0.00 | 1223038.86 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.139694E+10 | 0.00 | 0.00 | 2628397.19 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.134853E+10 | 0.00 | 0.00 | 6832278.92 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.101703E+10 | 0.00 | 0.00 | 8113524.14 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.125783E+10 | 0.00 | 0.00 | 6270590.95 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.119246E+10 | 0.00 | 0.00 | 7193752.85 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.114341E+10 | 0.00 | 0.00 | 10618750.61 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.969692E+09 | 0.00 | 0.00 | 17400688.68 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 31019.98 | 0.779759E+09 | 0.00 | 34298.81 | 26755357.79 | 0.00 | 110074.10 | 0.00 | 0.36 |
| Annual Sum or Average | 714116.85 | 0.126480E+11 | 0.00 | 40369.66 | 0.130734E+09 | 0.00 | 200662.08 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.726482E+09 | 0.00 | 0.00 | 1223038.86 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 601848.43 | 0.139694E+10 | 0.00 | 34298.81 | 26755357.79 | 0.00 | 110074.10 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 611710.05 | 0.725356E+09 | 0.00 | 2366.95 | 21171467.44 | 0.00 | 6883.56 | 0.00 | 0.36 |
| February | 84484.93 | 0.727635E+09 | 0.00 | 4184.04 | 18558449.66 | 0.00 | 85215.19 | 0.00 | 0.36 |
| March | 0.00 | 0.921755E+09 | 0.00 | 0.00 | 3814886.22 | 0.00 | 0.00 | 0.00 | 0.36 |
| April | 0.00 | 0.116288E+10 | 0.00 | 0.00 | 1224194.22 | 0.00 | 0.00 | 0.00 | 0.36 |
| May | 0.00 | 0.139584E+10 | 0.00 | 0.00 | 2622567.32 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.134751E+10 | 0.00 | 0.00 | 6818961.29 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.101590E+10 | 0.00 | 0.00 | 8119859.95 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.125685E+10 | 0.00 | 0.00 | 6263275.50 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.119142E+10 | 0.00 | 0.00 | 7162335.73 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 0.00 | 0.114234E+10 | 0.00 | 0.00 | 10517643.09 | 0.00 | 0.00 | 0.00 | 0.36 |
| November | 0.00 | 0.968527E+09 | 0.00 | 0.00 | 17390409.63 | 0.00 | 0.00 | 0.00 | 0.36 |
| December | 30460.42 | 0.778799E+09 | 0.00 | 34566.22 | 26558871.37 | 0.00 | 109908.71 | 0.00 | 0.36 |
| Annual Sum or Average | 726655.40 | 0.126348E+11 | 0.00 | 41117.21 | 0.130223E+09 | 0.00 | 202007.46 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.725356E+09 | 0.00 | 0.00 | 1224194.22 | 0.00 | 0.00 | 0.00 | 0.36 |
| Maximum of Months | 611710.05 | 0.139584E+10 | 0.00 | 34566.22 | 26558871.37 | 0.00 | 109908.71 | 0.00 | 0.36 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2024-07-03 12:21:15
Custom Monthly Report| SITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
| January | 0.118837E+12 | -0.205330E+10 | 0.00 | -507007910.2 | 0.168029E+12 |
| February | 0.112038E+12 | -0.252600E+10 | 0.00 | -633980152.9 | 0.161843E+12 |
| March | 0.136953E+12 | -0.472926E+10 | 0.00 | -949340166.9 | 0.188113E+12 |
| April | 0.133451E+12 | -0.503386E+10 | 0.00 | -0.118588E+10 | 0.196547E+12 |
| May | 0.141787E+12 | -0.653548E+10 | 0.00 | -0.157469E+10 | 0.215998E+12 |
| June | 0.148489E+12 | -0.624352E+10 | 0.00 | -0.152529E+10 | 0.214693E+12 |
| July | 0.124269E+12 | -0.330302E+10 | 0.00 | -848333158.7 | 0.185012E+12 |
| August | 0.150716E+12 | -0.572100E+10 | 0.00 | -0.131865E+10 | 0.194521E+12 |
| September | 0.118522E+12 | -0.373840E+10 | 0.00 | -0.113016E+10 | 0.185162E+12 |
| October | 0.136195E+12 | -0.336182E+10 | 0.00 | -0.101765E+10 | 0.180982E+12 |
| November | 0.114563E+12 | -0.243051E+10 | 0.00 | -807167520.9 | 0.171688E+12 |
| December | 0.113353E+12 | -0.193565E+10 | 0.00 | -500608795.7 | 0.166376E+12 |
| Annual Sum or Average | 0.154917E+13 | -0.476118E+11 | 0.00 | -0.119988E+11 | 0.222896E+13 |
| Minimum of Months | 0.112038E+12 | -0.653548E+10 | 0.00 | -0.157469E+10 | 0.161843E+12 |
| Maximum of Months | 0.150716E+12 | -0.193565E+10 | 0.00 | -500608795.7 | 0.215998E+12 |