Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2024.07.03 12:21
Tabular Output Report in Format: HTML
Building: ApartmentMidRise
Environment: RUNPERIOD 1 ** Tampa-MacDill AFB FL USA TMY3 WMO#=747880
Simulation Timestamp: 2024-07-03 12:21:22
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Values gathered over 8760.00 hours| Total Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
| Total Site Energy | 1296.96 | 413.76 | 459.27 |
| Net Site Energy | 1296.96 | 413.76 | 459.27 |
| Total Source Energy | 3369.79 | 1075.02 | 1193.28 |
| Net Source Energy | 3369.79 | 1075.02 | 1193.28 |
| Site=>Source Conversion Factor | |
| Electricity | 3.167 |
| Natural Gas | 1.084 |
| District Cooling | 1.056 |
| District Heating | 3.613 |
| Steam | 1.200 |
| Gasoline | 1.050 |
| Diesel | 1.050 |
| Coal | 1.050 |
| Fuel Oil No 1 | 1.050 |
| Fuel Oil No 2 | 1.050 |
| Propane | 1.050 |
| Other Fuel 1 | 1.000 |
| Other Fuel 2 | 1.000 |
| Area [m2] | |
| Total Building Area | 3134.61 |
| Net Conditioned Building Area | 2823.98 |
| Unconditioned Building Area | 310.64 |
| Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | 1.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 258.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 73.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 33.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 454.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 122.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 354.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.51 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 942.81 | 354.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.51 |
| Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | General | 1.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | General | 258.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | LightsWired | 67.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| LightsPlugIn | 5.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | General | 33.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | ElevatorLift | 67.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| ElevatorLightsFan | 0.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| MiscPlug | 386.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| General | 122.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Pumps | General | 0.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.51 | |
| Water Heater | 0.00 | 354.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | Unassigned | 1.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | Unassigned | 258.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | GENERAL | 73.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | Unassigned | 33.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | GENERAL | 454.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Unassigned | 122.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | Unassigned | 0.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Unassigned | 0.00 | 354.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.51 |
| Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 37.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 135.55 | 125.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| Other | 160.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 333.86 | 125.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 33.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 122.11 | 112.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| Other | 144.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 300.77 | 112.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| Electricity [GJ] | Percent Electricity [%] | |
| Fuel-Fired Power Generation | 0.000 | 0.00 |
| High Temperature Geothermal* | 0.000 | 0.00 |
| Photovoltaic Power | 0.000 | 0.00 |
| Wind Power | 0.000 | 0.00 |
| Power Conversion | 0.000 | 0.00 |
| Net Decrease in On-Site Storage | 0.000 | 0.00 |
| Total On-Site Electric Sources | 0.000 | 0.00 |
| Electricity Coming From Utility | 942.812 | 100.00 |
| Surplus Electricity Going To Utility | 0.000 | 0.00 |
| Net Electricity From Utility | 942.812 | 100.00 |
| Total On-Site and Utility Electric Sources | 942.812 | 100.00 |
| Total Electricity End Uses | 942.812 | 100.00 |
| Heat [GJ] | Percent Heat [%] | |
| Water-Side Heat Recovery | 0.00 | 0.00 |
| Air to Air Heat Recovery for Cooling | 126.63 | 61.40 |
| Air to Air Heat Recovery for Heating | 79.59 | 38.60 |
| High-Temperature Geothermal* | 0.00 | 0.00 |
| Solar Water Thermal | 0.00 | 0.00 |
| Solar Air Thermal | 0.00 | 0.00 |
| Total On-Site Thermal Sources | 206.22 | 100.00 |
| Water [m3] | Percent Water [%] | |
| Rainwater Collection | 0.00 | 0.00 |
| Condensate Collection | 0.00 | 0.00 |
| Groundwater Well | 0.00 | 0.00 |
| Total On Site Water Sources | 0.00 | 0.00 |
| - | - | - |
| Initial Storage | 0.00 | 0.00 |
| Final Storage | 0.00 | 0.00 |
| Change in Storage | 0.00 | 0.00 |
| - | - | - |
| Water Supplied by Utility | 1875.51 | 100.00 |
| - | - | - |
| Total On Site, Change in Storage, and Utility Water Sources | 1875.51 | 100.00 |
| Total Water End Uses | 1875.51 | 100.00 |
| Degrees [deltaC] | |
| Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
| Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
| Facility [Hours] | |
| Time Setpoint Not Met During Occupied Heating | 0.00 |
| Time Setpoint Not Met During Occupied Cooling | 0.00 |
| Time Not Comfortable Based on Simple ASHRAE 55-2004 | 8760.00 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 2A
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2019
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_FL_TAMPA
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PERFORMANCEPATHPROPOSED
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |ZoneCoolingSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ZoneHeatingSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ZoneElectricSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |SpaceGainsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |PeakSpaceGainsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |SpaceGainComponentsAtCoolingPeakMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ComfortReportSimple55Monthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |OccupantComfortDataSummaryMonthly
| OCCUP_GSW | OCCUP_GNW | OCCUP_OFFICE | OCCUP_GNE | OCCUP_GN1 | OCCUP_GN2 | OCCUP_GS1 | OCCUP_GS2 | OCCUP_MSW | OCCUP_MNW | OCCUP_MSE | OCCUP_MNE | OCCUP_MN1 | OCCUP_MN2 | OCCUP_MS1 | OCCUP_MS2 | OCCUP_TSW | OCCUP_TNW | OCCUP_TSE | OCCUP_TNE | OCCUP_TN1 | OCCUP_TN2 | OCCUP_TS1 | OCCUP_TS2 | OCCUP_T CORRIDOR | OCCUP_G CORRIDOR | OCCUP_M CORRIDOR |DXReportMonthly
| SPLIT GSW HP COOLING COIL | SPLIT GNW HP COOLING COIL | SPLIT OFFICE HP COOLING COIL | SPLIT GNE HP COOLING COIL | SPLIT GN1 HP COOLING COIL | SPLIT GN2 HP COOLING COIL | SPLIT GS1 HP COOLING COIL | SPLIT GS2 HP COOLING COIL | SPLIT MSW HP COOLING COIL | SPLIT MNW HP COOLING COIL | SPLIT MSE HP COOLING COIL | SPLIT MNE HP COOLING COIL | SPLIT MN1 HP COOLING COIL | SPLIT MN2 HP COOLING COIL | SPLIT MS1 HP COOLING COIL | SPLIT MS2 HP COOLING COIL | SPLIT TSW HP COOLING COIL | SPLIT TNW HP COOLING COIL | SPLIT TSE HP COOLING COIL | SPLIT TNE HP COOLING COIL | SPLIT TN1 HP COOLING COIL | SPLIT TN2 HP COOLING COIL | SPLIT TS1 HP COOLING COIL | SPLIT TS2 HP COOLING COIL |WindowReportMonthly
| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |WindowEnergyReportMonthly
| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |WindowZoneSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |WindowEnergyZoneSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| SWHSYS1 WATER HEATER |DaylightingReportMonthly
| Environment |CoilReportMonthly
| SPLIT GSW HEATING COIL | SPLIT GNW HEATING COIL | SPLIT OFFICE HEATING COIL | SPLIT GNE HEATING COIL | SPLIT GN1 HEATING COIL | SPLIT GN2 HEATING COIL | SPLIT GS1 HEATING COIL | SPLIT GS2 HEATING COIL | SPLIT MSW HEATING COIL | SPLIT MNW HEATING COIL | SPLIT MSE HEATING COIL | SPLIT MNE HEATING COIL | SPLIT MN1 HEATING COIL | SPLIT MN2 HEATING COIL | SPLIT MS1 HEATING COIL | SPLIT MS2 HEATING COIL | SPLIT TSW HEATING COIL | SPLIT TNW HEATING COIL | SPLIT TSE HEATING COIL | SPLIT TNE HEATING COIL | SPLIT TN1 HEATING COIL | SPLIT TN2 HEATING COIL | SPLIT TS1 HEATING COIL | SPLIT TS2 HEATING COIL | SPLIT GSW_SUPPHEATCOIL | SPLIT GNW_SUPPHEATCOIL | SPLIT OFFICE_SUPPHEATCOIL | SPLIT GNE_SUPPHEATCOIL | SPLIT GN1_SUPPHEATCOIL | SPLIT GN2_SUPPHEATCOIL | SPLIT GS1_SUPPHEATCOIL | SPLIT GS2_SUPPHEATCOIL | SPLIT MSW_SUPPHEATCOIL | SPLIT MNW_SUPPHEATCOIL | SPLIT MSE_SUPPHEATCOIL | SPLIT MNE_SUPPHEATCOIL | SPLIT MN1_SUPPHEATCOIL | SPLIT MN2_SUPPHEATCOIL | SPLIT MS1_SUPPHEATCOIL | SPLIT MS2_SUPPHEATCOIL | SPLIT TSW_SUPPHEATCOIL | SPLIT TNW_SUPPHEATCOIL | SPLIT TSE_SUPPHEATCOIL | SPLIT TNE_SUPPHEATCOIL | SPLIT TN1_SUPPHEATCOIL | SPLIT TN2_SUPPHEATCOIL | SPLIT TS1_SUPPHEATCOIL | SPLIT TS2_SUPPHEATCOIL | SPLIT GSW HP COOLING COIL | SPLIT GNW HP COOLING COIL | SPLIT OFFICE HP COOLING COIL | SPLIT GNE HP COOLING COIL | SPLIT GN1 HP COOLING COIL | SPLIT GN2 HP COOLING COIL | SPLIT GS1 HP COOLING COIL | SPLIT GS2 HP COOLING COIL | SPLIT MSW HP COOLING COIL | SPLIT MNW HP COOLING COIL | SPLIT MSE HP COOLING COIL | SPLIT MNE HP COOLING COIL | SPLIT MN1 HP COOLING COIL | SPLIT MN2 HP COOLING COIL | SPLIT MS1 HP COOLING COIL | SPLIT MS2 HP COOLING COIL | SPLIT TSW HP COOLING COIL | SPLIT TNW HP COOLING COIL | SPLIT TSE HP COOLING COIL | SPLIT TNE HP COOLING COIL | SPLIT TN1 HP COOLING COIL | SPLIT TN2 HP COOLING COIL | SPLIT TS1 HP COOLING COIL | SPLIT TS2 HP COOLING COIL |PlantLoopDemandReportMonthly
| SWHSYS1 |FanReportMonthly
| SPLIT GSW SUPPLY FAN | G SW APARTMENT ERV SUP FAN | G SW APARTMENT ERV EXH FAN | SPLIT GNW SUPPLY FAN | G NW APARTMENT ERV SUP FAN | G NW APARTMENT ERV EXH FAN | SPLIT OFFICE SUPPLY FAN | SPLIT GNE SUPPLY FAN | G NE APARTMENT ERV SUP FAN | G NE APARTMENT ERV EXH FAN | SPLIT GN1 SUPPLY FAN | G N1 APARTMENT ERV SUP FAN | G N1 APARTMENT ERV EXH FAN | SPLIT GN2 SUPPLY FAN | G N2 APARTMENT ERV SUP FAN | G N2 APARTMENT ERV EXH FAN | SPLIT GS1 SUPPLY FAN | G S1 APARTMENT ERV SUP FAN | G S1 APARTMENT ERV EXH FAN | SPLIT GS2 SUPPLY FAN | G S2 APARTMENT ERV SUP FAN | G S2 APARTMENT ERV EXH FAN | SPLIT MSW SUPPLY FAN | M SW APARTMENT ERV SUP FAN | M SW APARTMENT ERV EXH FAN | SPLIT MNW SUPPLY FAN | M NW APARTMENT ERV SUP FAN | M NW APARTMENT ERV EXH FAN | SPLIT MSE SUPPLY FAN | M SE APARTMENT ERV SUP FAN | M SE APARTMENT ERV EXH FAN | SPLIT MNE SUPPLY FAN | M NE APARTMENT ERV SUP FAN | M NE APARTMENT ERV EXH FAN | SPLIT MN1 SUPPLY FAN | M N1 APARTMENT ERV SUP FAN | M N1 APARTMENT ERV EXH FAN | SPLIT MN2 SUPPLY FAN | M N2 APARTMENT ERV SUP FAN | M N2 APARTMENT ERV EXH FAN | SPLIT MS1 SUPPLY FAN | M S1 APARTMENT ERV SUP FAN | M S1 APARTMENT ERV EXH FAN | SPLIT MS2 SUPPLY FAN | M S2 APARTMENT ERV SUP FAN | M S2 APARTMENT ERV EXH FAN | SPLIT TSW SUPPLY FAN | T SW APARTMENT ERV SUP FAN | T SW APARTMENT ERV EXH FAN | SPLIT TNW SUPPLY FAN | T NW APARTMENT ERV SUP FAN | T NW APARTMENT ERV EXH FAN | SPLIT TSE SUPPLY FAN | T SE APARTMENT ERV SUP FAN | T SE APARTMENT ERV EXH FAN | SPLIT TNE SUPPLY FAN | T NE APARTMENT ERV SUP FAN | T NE APARTMENT ERV EXH FAN | SPLIT TN1 SUPPLY FAN | T N1 APARTMENT ERV SUP FAN | T N1 APARTMENT ERV EXH FAN | SPLIT TN2 SUPPLY FAN | T N2 APARTMENT ERV SUP FAN | T N2 APARTMENT ERV EXH FAN | SPLIT TS1 SUPPLY FAN | T S1 APARTMENT ERV SUP FAN | T S1 APARTMENT ERV EXH FAN | SPLIT TS2 SUPPLY FAN | T S2 APARTMENT ERV SUP FAN | T S2 APARTMENT ERV EXH FAN |PumpReportMonthly
| SWHSYS1 PUMP |CondLoopDemandReportMonthly
| SWHSYS1 |ZoneTemperatureOscillationReportMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |AirLoopSystemEnergyAndWaterUseMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |AirLoopSystemComponentLoadsMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |AirLoopSystemComponentEnergyUseMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |MechanicalVentilationLoadsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
General| Value | |
| Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2024.07.03 12:21 |
| RunPeriod | RUNPERIOD 1 |
| Weather File | Tampa-MacDill AFB FL USA TMY3 WMO#=747880 |
| Latitude [deg] | 27.85 |
| Longitude [deg] | -82.5 |
| Elevation [m] | 8.00 |
| Time Zone | -5.0 |
| North Axis Angle [deg] | 0.00 |
| Rotation for Appendix G [deg] | 0.00 |
| Hours Simulated [hrs] | 8760.00 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
| Above Ground Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
| Window Opening Area [m2] | 306.92 | 112.97 | 43.82 | 112.97 | 37.16 |
| Gross Window-Wall Ratio [%] | 19.90 | 20.00 | 21.25 | 20.00 | 18.02 |
| Above Ground Window-Wall Ratio [%] | 19.90 | 20.00 | 21.25 | 20.00 | 18.02 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
| Above Ground Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
| Window Opening Area [m2] | 300.26 | 112.97 | 37.16 | 112.97 | 37.16 |
| Gross Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Above Ground Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Total | |
| Gross Roof Area [m2] | 783.65 |
| Skylight Area [m2] | 0.00 |
| Skylight-Roof Ratio [%] | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| G SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| G NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| OFFICE | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 7.4895 | 18.58 | 6.6700 |
| G NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| G N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| G S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| M SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| M NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| M SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| M NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| M N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| M S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| T SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| T NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| T SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| T NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| T N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| T S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 0.00 | 1.11 | 1.11 | 5.2871 | 18.58 | 0.0000 |
| G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 0.00 | 3.32 | 3.32 | 5.2871 | 18.58 | 515.3919 |
| M CORRIDOR | 77.66 | No | Yes | 236.69 | 2.00 | 10.22 | 0.00 | 1.11 | 1.11 | 5.2871 | 18.58 | 0.0000 |
| Total | 3134.61 | 9553.84 | 1542.04 | 0.00 | 306.92 | 306.92 | 5.5258 | 31.67 | 18.7777 | |||
| Conditioned Total | 2823.98 | 8607.06 | 1501.17 | 0.00 | 300.26 | 300.26 | 5.5521 | 34.33 | 6.6700 | |||
| Unconditioned Total | 310.64 | 946.78 | 40.87 | 0.00 | 6.66 | 6.66 | 5.2871 | 18.58 | 128.8480 | |||
| Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
| G SW APARTMENT | 88.25 | Yes | Yes | 1.00 | G SW APARTMENT | GENERAL | G SW APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| G NW APARTMENT | 88.25 | Yes | Yes | 1.00 | G NW APARTMENT | GENERAL | G NW APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| OFFICE | 88.25 | Yes | Yes | 1.00 | OFFICE | GENERAL | OFFICE | 7.4895 | 18.58 | 6.6700 | |
| G NE APARTMENT | 88.25 | Yes | Yes | 1.00 | G NE APARTMENT | GENERAL | G NE APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| G N1 APARTMENT | 88.25 | Yes | Yes | 1.00 | G N1 APARTMENT | GENERAL | G N1 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| G N2 APARTMENT | 88.25 | Yes | Yes | 1.00 | G N2 APARTMENT | GENERAL | G N2 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| G S1 APARTMENT | 88.25 | Yes | Yes | 1.00 | G S1 APARTMENT | GENERAL | G S1 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| G S2 APARTMENT | 88.25 | Yes | Yes | 1.00 | G S2 APARTMENT | GENERAL | G S2 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M SW APARTMENT | 88.25 | Yes | Yes | 2.00 | M SW APARTMENT | GENERAL | M SW APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M NW APARTMENT | 88.25 | Yes | Yes | 2.00 | M NW APARTMENT | GENERAL | M NW APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M SE APARTMENT | 88.25 | Yes | Yes | 2.00 | M SE APARTMENT | GENERAL | M SE APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M NE APARTMENT | 88.25 | Yes | Yes | 2.00 | M NE APARTMENT | GENERAL | M NE APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M N1 APARTMENT | 88.25 | Yes | Yes | 2.00 | M N1 APARTMENT | GENERAL | M N1 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M N2 APARTMENT | 88.25 | Yes | Yes | 2.00 | M N2 APARTMENT | GENERAL | M N2 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M S1 APARTMENT | 88.25 | Yes | Yes | 2.00 | M S1 APARTMENT | GENERAL | M S1 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M S2 APARTMENT | 88.25 | Yes | Yes | 2.00 | M S2 APARTMENT | GENERAL | M S2 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T SW APARTMENT | 88.25 | Yes | Yes | 1.00 | T SW APARTMENT | GENERAL | T SW APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T NW APARTMENT | 88.25 | Yes | Yes | 1.00 | T NW APARTMENT | GENERAL | T NW APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T SE APARTMENT | 88.25 | Yes | Yes | 1.00 | T SE APARTMENT | GENERAL | T SE APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T NE APARTMENT | 88.25 | Yes | Yes | 1.00 | T NE APARTMENT | GENERAL | T NE APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T N1 APARTMENT | 88.25 | Yes | Yes | 1.00 | T N1 APARTMENT | GENERAL | T N1 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T N2 APARTMENT | 88.25 | Yes | Yes | 1.00 | T N2 APARTMENT | GENERAL | T N2 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T S1 APARTMENT | 88.25 | Yes | Yes | 1.00 | T S1 APARTMENT | GENERAL | T S1 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T S2 APARTMENT | 88.25 | Yes | Yes | 1.00 | T S2 APARTMENT | GENERAL | T S2 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T CORRIDOR | 77.66 | No | Yes | 1.00 | T CORRIDOR | GENERAL | T CORRIDOR | 5.2871 | 18.58 | 0.0000 | |
| G CORRIDOR | 77.66 | No | Yes | 1.00 | G CORRIDOR | GENERAL | G CORRIDOR | 5.2871 | 18.58 | 515.3919 | |
| M CORRIDOR | 77.66 | No | Yes | 2.00 | M CORRIDOR | GENERAL | M CORRIDOR | 5.2871 | 18.58 | 0.0000 | |
| Total | 3134.61 | 5.5258 | 15.84 | 18.7777 | |||||||
| Conditioned Total | 2823.98 | 5.5521 | 17.17 | 6.6700 | |||||||
| Unconditioned Total | 310.64 | 5.2871 | 9.29 | 128.8480 | |||||||
| Not Part of Total | 0.00 | 0.0000 | 0.00 | 0.0000 |
| Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| GENERAL | 3134.61 | 2823.98 | 310.64 | 0.00 | 4.1584 | 41.91 | 17.2755 |
| Total | 3134.61 | 2823.98 | 310.64 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
End Uses| Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Time of Peak | 10-SEP-16:10 | 26-JAN-07:00 | - | - | - | - | - | - | - | - | - | - | 01-JAN-07:10 |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 24669.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 3020.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 22179.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 7577.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 14.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 24157.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 57461.20 | 24157.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | General | 24669.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | LightsWired | 2720.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| LightsPlugIn | 299.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | ElevatorLift | 3772.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| ElevatorLightsFan | 31.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| MiscPlug | 18375.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| General | 7577.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Pumps | General | 14.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Water Heater | 0.00 | 24157.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Values gathered over 8760.00 hours| Source Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
| Heating | 5.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 818.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 231.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 104.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 1437.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 386.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 1.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 383.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 2985.88 | 383.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 1.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 289.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 81.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 37.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 509.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 136.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 135.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 1057.33 | 135.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 1.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 261.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 73.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 33.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 458.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 123.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 122.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 952.55 | 122.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
ZoneHVAC:EnergyRecoveryVentilator| User-Specified Supply Air Flow Rate [m3/s] | User-Specified Exhaust Air Flow Rate [m3/s] | |
| G SW APARTMENT ERV | 0.025955 | 0.025955 |
| G NW APARTMENT ERV | 0.025955 | 0.025955 |
| G NE APARTMENT ERV | 0.025955 | 0.025955 |
| G N1 APARTMENT ERV | 0.025955 | 0.025955 |
| G N2 APARTMENT ERV | 0.025955 | 0.025955 |
| G S1 APARTMENT ERV | 0.025955 | 0.025955 |
| G S2 APARTMENT ERV | 0.025955 | 0.025955 |
| M SW APARTMENT ERV | 0.051909 | 0.051909 |
| M NW APARTMENT ERV | 0.051909 | 0.051909 |
| M SE APARTMENT ERV | 0.051909 | 0.051909 |
| M NE APARTMENT ERV | 0.051909 | 0.051909 |
| M N1 APARTMENT ERV | 0.051909 | 0.051909 |
| M N2 APARTMENT ERV | 0.051909 | 0.051909 |
| M S1 APARTMENT ERV | 0.051909 | 0.051909 |
| M S2 APARTMENT ERV | 0.051909 | 0.051909 |
| T SW APARTMENT ERV | 0.025955 | 0.025955 |
| T NW APARTMENT ERV | 0.025955 | 0.025955 |
| T SE APARTMENT ERV | 0.025955 | 0.025955 |
| T NE APARTMENT ERV | 0.025955 | 0.025955 |
| T N1 APARTMENT ERV | 0.025955 | 0.025955 |
| T N2 APARTMENT ERV | 0.025955 | 0.025955 |
| T S1 APARTMENT ERV | 0.025955 | 0.025955 |
| T S2 APARTMENT ERV | 0.025955 | 0.025955 |
| Design Size Maximum Flow Rate [m3/s] | |
| G SW APARTMENT ERV SUP FAN | 0.025955 |
| G SW APARTMENT ERV EXH FAN | 0.025955 |
| G NW APARTMENT ERV SUP FAN | 0.025955 |
| G NW APARTMENT ERV EXH FAN | 0.025955 |
| G NE APARTMENT ERV SUP FAN | 0.025955 |
| G NE APARTMENT ERV EXH FAN | 0.025955 |
| G N1 APARTMENT ERV SUP FAN | 0.025955 |
| G N1 APARTMENT ERV EXH FAN | 0.025955 |
| G N2 APARTMENT ERV SUP FAN | 0.025955 |
| G N2 APARTMENT ERV EXH FAN | 0.025955 |
| G S1 APARTMENT ERV SUP FAN | 0.025955 |
| G S1 APARTMENT ERV EXH FAN | 0.025955 |
| G S2 APARTMENT ERV SUP FAN | 0.025955 |
| G S2 APARTMENT ERV EXH FAN | 0.025955 |
| M SW APARTMENT ERV SUP FAN | 0.051909 |
| M SW APARTMENT ERV EXH FAN | 0.051909 |
| M NW APARTMENT ERV SUP FAN | 0.051909 |
| M NW APARTMENT ERV EXH FAN | 0.051909 |
| M SE APARTMENT ERV SUP FAN | 0.051909 |
| M SE APARTMENT ERV EXH FAN | 0.051909 |
| M NE APARTMENT ERV SUP FAN | 0.051909 |
| M NE APARTMENT ERV EXH FAN | 0.051909 |
| M N1 APARTMENT ERV SUP FAN | 0.051909 |
| M N1 APARTMENT ERV EXH FAN | 0.051909 |
| M N2 APARTMENT ERV SUP FAN | 0.051909 |
| M N2 APARTMENT ERV EXH FAN | 0.051909 |
| M S1 APARTMENT ERV SUP FAN | 0.051909 |
| M S1 APARTMENT ERV EXH FAN | 0.051909 |
| M S2 APARTMENT ERV SUP FAN | 0.051909 |
| M S2 APARTMENT ERV EXH FAN | 0.051909 |
| T SW APARTMENT ERV SUP FAN | 0.025955 |
| T SW APARTMENT ERV EXH FAN | 0.025955 |
| T NW APARTMENT ERV SUP FAN | 0.025955 |
| T NW APARTMENT ERV EXH FAN | 0.025955 |
| T SE APARTMENT ERV SUP FAN | 0.025955 |
| T SE APARTMENT ERV EXH FAN | 0.025955 |
| T NE APARTMENT ERV SUP FAN | 0.025955 |
| T NE APARTMENT ERV EXH FAN | 0.025955 |
| T N1 APARTMENT ERV SUP FAN | 0.025955 |
| T N1 APARTMENT ERV EXH FAN | 0.025955 |
| T N2 APARTMENT ERV SUP FAN | 0.025955 |
| T N2 APARTMENT ERV EXH FAN | 0.025955 |
| T S1 APARTMENT ERV SUP FAN | 0.025955 |
| T S1 APARTMENT ERV EXH FAN | 0.025955 |
| T S2 APARTMENT ERV SUP FAN | 0.025955 |
| T S2 APARTMENT ERV EXH FAN | 0.025955 |
| SPLIT GSW SUPPLY FAN | 0.318135 |
| SPLIT GNW SUPPLY FAN | 0.302480 |
| SPLIT OFFICE SUPPLY FAN | 0.368100 |
| SPLIT GNE SUPPLY FAN | 0.280767 |
| SPLIT GN1 SUPPLY FAN | 0.245959 |
| SPLIT GN2 SUPPLY FAN | 0.245562 |
| SPLIT GS1 SUPPLY FAN | 0.266249 |
| SPLIT GS2 SUPPLY FAN | 0.269108 |
| SPLIT MSW SUPPLY FAN | 0.705021 |
| SPLIT MNW SUPPLY FAN | 0.671528 |
| SPLIT MSE SUPPLY FAN | 0.646921 |
| SPLIT MNE SUPPLY FAN | 0.614042 |
| SPLIT MN1 SUPPLY FAN | 0.546385 |
| SPLIT MN2 SUPPLY FAN | 0.545363 |
| SPLIT MS1 SUPPLY FAN | 0.582439 |
| SPLIT MS2 SUPPLY FAN | 0.581496 |
| SPLIT TSW SUPPLY FAN | 0.392115 |
| SPLIT TNW SUPPLY FAN | 0.379559 |
| SPLIT TSE SUPPLY FAN | 0.348850 |
| SPLIT TNE SUPPLY FAN | 0.336334 |
| SPLIT TN1 SUPPLY FAN | 0.312298 |
| SPLIT TN2 SUPPLY FAN | 0.310904 |
| SPLIT TS1 SUPPLY FAN | 0.325944 |
| SPLIT TS2 SUPPLY FAN | 0.324546 |
| Design Size Nominal Supply Air Flow Rate [m3/s] | |
| G SW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G NW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G NE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G N1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G N2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G S1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G S2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| M SW APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M NW APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M SE APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M NE APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M N1 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M N2 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M S1 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M S2 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| T SW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T NW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T SE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T NE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T N1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T N2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T S1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T S2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| Design Size Maximum Air Flow Rate [m3/s] | |
| G SW APARTMENT DIRECT AIR | 0.318135 |
| G NW APARTMENT DIRECT AIR | 0.302480 |
| OFFICE DIRECT AIR | 0.368100 |
| G NE APARTMENT DIRECT AIR | 0.280767 |
| G N1 APARTMENT DIRECT AIR | 0.245959 |
| G N2 APARTMENT DIRECT AIR | 0.245562 |
| G S1 APARTMENT DIRECT AIR | 0.266249 |
| G S2 APARTMENT DIRECT AIR | 0.269108 |
| M SW APARTMENT DIRECT AIR | 0.705021 |
| M NW APARTMENT DIRECT AIR | 0.671528 |
| M SE APARTMENT DIRECT AIR | 0.646921 |
| M NE APARTMENT DIRECT AIR | 0.614042 |
| M N1 APARTMENT DIRECT AIR | 0.546385 |
| M N2 APARTMENT DIRECT AIR | 0.545363 |
| M S1 APARTMENT DIRECT AIR | 0.582439 |
| M S2 APARTMENT DIRECT AIR | 0.581496 |
| T SW APARTMENT DIRECT AIR | 0.392115 |
| T NW APARTMENT DIRECT AIR | 0.379559 |
| T SE APARTMENT DIRECT AIR | 0.348850 |
| T NE APARTMENT DIRECT AIR | 0.336334 |
| T N1 APARTMENT DIRECT AIR | 0.312298 |
| T N2 APARTMENT DIRECT AIR | 0.310904 |
| T S1 APARTMENT DIRECT AIR | 0.325944 |
| T S2 APARTMENT DIRECT AIR | 0.324546 |
| Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
| SPLIT GSW | 0.318135 | 0.318135 | 0.318135 | 0.318135 | 0.318135 | 0.318135 | 1.00 | 1.00 | 0.318135 |
| SPLIT GNW | 0.302480 | 0.302480 | 0.302480 | 0.302480 | 0.302480 | 0.302480 | 1.00 | 1.00 | 0.302480 |
| SPLIT OFFICE | 0.368100 | 0.368100 | 0.368100 | 0.368100 | 0.368100 | 0.368100 | 1.00 | 1.00 | 0.368100 |
| SPLIT GNE | 0.280767 | 0.280767 | 0.280767 | 0.280767 | 0.280767 | 0.280767 | 1.00 | 1.00 | 0.280767 |
| SPLIT GN1 | 0.245959 | 0.245959 | 0.245959 | 0.245959 | 0.245959 | 0.245959 | 1.00 | 1.00 | 0.245959 |
| SPLIT GN2 | 0.245562 | 0.245562 | 0.245562 | 0.245562 | 0.245562 | 0.245562 | 1.00 | 1.00 | 0.245562 |
| SPLIT GS1 | 0.266249 | 0.266249 | 0.266249 | 0.266249 | 0.266249 | 0.266249 | 1.00 | 1.000000 | 0.266249 |
| SPLIT GS2 | 0.269108 | 0.269108 | 0.269108 | 0.269108 | 0.269108 | 0.269108 | 1.00 | 1.00 | 0.269108 |
| SPLIT MSW | 0.705021 | 0.705021 | 0.705021 | 0.705021 | 0.705021 | 0.705021 | 1.00 | 1.00 | 0.705021 |
| SPLIT MNW | 0.671528 | 0.671528 | 0.671528 | 0.671528 | 0.671528 | 0.671528 | 1.00 | 1.00 | 0.671528 |
| SPLIT MSE | 0.646921 | 0.646921 | 0.646921 | 0.646921 | 0.646921 | 0.646921 | 1.00 | 1.00 | 0.646921 |
| SPLIT MNE | 0.614042 | 0.614042 | 0.614042 | 0.614042 | 0.614042 | 0.614042 | 1.00 | 1.00 | 0.614042 |
| SPLIT MN1 | 0.546385 | 0.546385 | 0.546385 | 0.546385 | 0.546385 | 0.546385 | 1.00 | 1.00 | 0.546385 |
| SPLIT MN2 | 0.545363 | 0.545363 | 0.545363 | 0.545363 | 0.545363 | 0.545363 | 1.00 | 1.00 | 0.545363 |
| SPLIT MS1 | 0.582439 | 0.582439 | 0.582439 | 0.582439 | 0.582439 | 0.582439 | 1.00 | 1.00 | 0.582439 |
| SPLIT MS2 | 0.581496 | 0.581496 | 0.581496 | 0.581496 | 0.581496 | 0.581496 | 1.00 | 1.000000 | 0.581496 |
| SPLIT TSW | 0.392115 | 0.392115 | 0.392115 | 0.392115 | 0.392115 | 0.392115 | 1.00 | 1.00 | 0.392115 |
| SPLIT TNW | 0.379559 | 0.379559 | 0.379559 | 0.379559 | 0.379559 | 0.379559 | 1.00 | 1.00 | 0.379559 |
| SPLIT TSE | 0.348850 | 0.348850 | 0.348850 | 0.348850 | 0.348850 | 0.348850 | 1.00 | 1.00 | 0.348850 |
| SPLIT TNE | 0.336334 | 0.336334 | 0.336334 | 0.336334 | 0.336334 | 0.336334 | 1.00 | 1.00 | 0.336334 |
| SPLIT TN1 | 0.312298 | 0.312298 | 0.312298 | 0.312298 | 0.312298 | 0.312298 | 1.00 | 1.00 | 0.312298 |
| SPLIT TN2 | 0.310904 | 0.310904 | 0.310904 | 0.310904 | 0.310904 | 0.310904 | 1.00 | 1.00 | 0.310904 |
| SPLIT TS1 | 0.325944 | 0.325944 | 0.325944 | 0.325944 | 0.325944 | 0.325944 | 1.00 | 1.00 | 0.325944 |
| SPLIT TS2 | 0.324546 | 0.324546 | 0.324546 | 0.324546 | 0.324546 | 0.324546 | 1.00 | 1.00 | 0.324546 |
| Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
| SPLIT GSW_OA_CONTROLLER | 0.318135 | 0.025955 |
| SPLIT GNW_OA_CONTROLLER | 0.302480 | 0.025955 |
| SPLIT OFFICE_OA_CONTROLLER | 0.368100 | 0.038106 |
| SPLIT GNE_OA_CONTROLLER | 0.280767 | 0.025955 |
| SPLIT GN1_OA_CONTROLLER | 0.245959 | 0.025955 |
| SPLIT GN2_OA_CONTROLLER | 0.245562 | 0.025955 |
| SPLIT GS1_OA_CONTROLLER | 0.266249 | 0.025955 |
| SPLIT GS2_OA_CONTROLLER | 0.269108 | 0.025955 |
| SPLIT MSW_OA_CONTROLLER | 0.705021 | 0.051909 |
| SPLIT MNW_OA_CONTROLLER | 0.671528 | 0.051909 |
| SPLIT MSE_OA_CONTROLLER | 0.646921 | 0.051909 |
| SPLIT MNE_OA_CONTROLLER | 0.614042 | 0.051909 |
| SPLIT MN1_OA_CONTROLLER | 0.546385 | 0.051909 |
| SPLIT MN2_OA_CONTROLLER | 0.545363 | 0.051909 |
| SPLIT MS1_OA_CONTROLLER | 0.582439 | 0.051909 |
| SPLIT MS2_OA_CONTROLLER | 0.581496 | 0.051909 |
| SPLIT TSW_OA_CONTROLLER | 0.392115 | 0.025955 |
| SPLIT TNW_OA_CONTROLLER | 0.379559 | 0.025955 |
| SPLIT TSE_OA_CONTROLLER | 0.348850 | 0.025955 |
| SPLIT TNE_OA_CONTROLLER | 0.336334 | 0.025955 |
| SPLIT TN1_OA_CONTROLLER | 0.312298 | 0.025955 |
| SPLIT TN2_OA_CONTROLLER | 0.310904 | 0.025955 |
| SPLIT TS1_OA_CONTROLLER | 0.325944 | 0.025955 |
| SPLIT TS2_OA_CONTROLLER | 0.324546 | 0.025955 |
| Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | Design Size Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | User-Specified Supplemental Heating Coil Nominal Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
| SPLIT GSW_UNITARY_PACKAGE_DX | 0.318135 | 0.318135 | 0.318135 | 0.318135 | 5811.38 | 3893.62 | 40.00 | 5811.38 | 1.00 |
| SPLIT GNW_UNITARY_PACKAGE_DX | 0.302480 | 0.302480 | 0.302480 | 0.302480 | 5546.73 | 3716.31 | 40.00 | 5546.73 | 1.00 |
| SPLIT OFFICE_UNITARY_PACKAGE_DX | 0.368100 | 0.368100 | 0.368100 | 0.368100 | 6706.83 | 4493.57 | 40.00 | 6706.83 | 1.00 |
| SPLIT GNE_UNITARY_PACKAGE_DX | 0.280767 | 0.280767 | 0.280767 | 0.280767 | 5222.70 | 3499.21 | 40.00 | 5222.70 | 1.00 |
| SPLIT GN1_UNITARY_PACKAGE_DX | 0.245959 | 0.245959 | 0.245959 | 0.245959 | 4668.56 | 3127.94 | 40.00 | 4668.56 | 1.00 |
| SPLIT GN2_UNITARY_PACKAGE_DX | 0.245562 | 0.245562 | 0.245562 | 0.245562 | 4662.41 | 3123.81 | 40.00 | 4662.41 | 1.00 |
| SPLIT GS1_UNITARY_PACKAGE_DX | 0.266249 | 0.266249 | 0.266249 | 0.266249 | 5025.49 | 3367.08 | 40.00 | 5025.49 | 1.00 |
| SPLIT GS2_UNITARY_PACKAGE_DX | 0.269108 | 0.269108 | 0.269108 | 0.269108 | 5068.80 | 3396.09 | 40.00 | 5068.80 | 1.00 |
| SPLIT MSW_UNITARY_PACKAGE_DX | 0.705021 | 0.705021 | 0.705021 | 0.705021 | 12723.10 | 8524.48 | 40.00 | 12723.10 | 1.00 |
| SPLIT MNW_UNITARY_PACKAGE_DX | 0.671528 | 0.671528 | 0.671528 | 0.671528 | 12174.35 | 8156.82 | 40.00 | 12174.35 | 1.00 |
| SPLIT MSE_UNITARY_PACKAGE_DX | 0.646921 | 0.646921 | 0.646921 | 0.646921 | 11866.13 | 7950.31 | 40.00 | 11866.13 | 1.00 |
| SPLIT MNE_UNITARY_PACKAGE_DX | 0.614042 | 0.614042 | 0.614042 | 0.614042 | 11317.74 | 7582.88 | 40.00 | 11317.74 | 1.00 |
| SPLIT MN1_UNITARY_PACKAGE_DX | 0.546385 | 0.546385 | 0.546385 | 0.546385 | 10244.58 | 6863.87 | 40.00 | 10244.58 | 1.00 |
| SPLIT MN2_UNITARY_PACKAGE_DX | 0.545363 | 0.545363 | 0.545363 | 0.545363 | 10228.45 | 6853.06 | 40.00 | 10228.45 | 1.00 |
| SPLIT MS1_UNITARY_PACKAGE_DX | 0.582439 | 0.582439 | 0.582439 | 0.582439 | 10851.74 | 7270.67 | 40.00 | 10851.74 | 1.00 |
| SPLIT MS2_UNITARY_PACKAGE_DX | 0.581496 | 0.581496 | 0.581496 | 0.581496 | 10837.45 | 7261.09 | 40.00 | 10837.45 | 1.00 |
| SPLIT TSW_UNITARY_PACKAGE_DX | 0.392115 | 0.392115 | 0.392115 | 0.392115 | 6984.29 | 4679.47 | 40.00 | 6984.29 | 1.00 |
| SPLIT TNW_UNITARY_PACKAGE_DX | 0.379559 | 0.379559 | 0.379559 | 0.379559 | 6777.00 | 4540.59 | 40.00 | 6777.00 | 1.00 |
| SPLIT TSE_UNITARY_PACKAGE_DX | 0.348850 | 0.348850 | 0.348850 | 0.348850 | 6327.96 | 4239.73 | 40.00 | 6327.96 | 1.00 |
| SPLIT TNE_UNITARY_PACKAGE_DX | 0.336334 | 0.336334 | 0.336334 | 0.336334 | 6119.01 | 4099.74 | 40.00 | 6119.01 | 1.00 |
| SPLIT TN1_UNITARY_PACKAGE_DX | 0.312298 | 0.312298 | 0.312298 | 0.312298 | 5703.00 | 3821.01 | 40.00 | 5703.00 | 1.00 |
| SPLIT TN2_UNITARY_PACKAGE_DX | 0.310904 | 0.310904 | 0.310904 | 0.310904 | 5681.79 | 3806.80 | 40.00 | 5681.79 | 1.00 |
| SPLIT TS1_UNITARY_PACKAGE_DX | 0.325944 | 0.325944 | 0.325944 | 0.325944 | 5932.13 | 3974.52 | 40.00 | 5932.13 | 1.00 |
| SPLIT TS2_UNITARY_PACKAGE_DX | 0.324546 | 0.324546 | 0.324546 | 0.324546 | 5911.00 | 3960.37 | 40.00 | 5911.00 | 1.00 |
| Design Size Rated Air Flow Rate [m3/s] | Design Size Gross Rated Total Cooling Capacity [W] | Design Size Gross Rated Sensible Heat Ratio | |
| SPLIT GSW HP COOLING COIL | 0.318135 | 5811.38 | 0.800169 |
| SPLIT GNW HP COOLING COIL | 0.302480 | 5546.73 | 0.800888 |
| SPLIT OFFICE HP COOLING COIL | 0.368100 | 6706.83 | 0.800026 |
| SPLIT GNE HP COOLING COIL | 0.280767 | 5222.70 | 0.800178 |
| SPLIT GN1 HP COOLING COIL | 0.245959 | 4668.56 | 0.797636 |
| SPLIT GN2 HP COOLING COIL | 0.245562 | 4662.41 | 0.797541 |
| SPLIT GS1 HP COOLING COIL | 0.266249 | 5025.49 | 0.800435 |
| SPLIT GS2 HP COOLING COIL | 0.269108 | 5068.80 | 0.800112 |
| SPLIT MSW HP COOLING COIL | 0.705021 | 12723.10 | 0.800241 |
| SPLIT MNW HP COOLING COIL | 0.671528 | 12174.35 | 0.800699 |
| SPLIT MSE HP COOLING COIL | 0.646921 | 11866.13 | 0.800798 |
| SPLIT MNE HP COOLING COIL | 0.614042 | 11317.74 | 0.800195 |
| SPLIT MN1 HP COOLING COIL | 0.546385 | 10244.58 | 0.800591 |
| SPLIT MN2 HP COOLING COIL | 0.545363 | 10228.45 | 0.800495 |
| SPLIT MS1 HP COOLING COIL | 0.582439 | 10851.74 | 0.800650 |
| SPLIT MS2 HP COOLING COIL | 0.581496 | 10837.45 | 0.800551 |
| SPLIT TSW HP COOLING COIL | 0.392115 | 6984.29 | 0.800683 |
| SPLIT TNW HP COOLING COIL | 0.379559 | 6777.00 | 0.800858 |
| SPLIT TSE HP COOLING COIL | 0.348850 | 6327.96 | 0.800512 |
| SPLIT TNE HP COOLING COIL | 0.336334 | 6119.01 | 0.800519 |
| SPLIT TN1 HP COOLING COIL | 0.312298 | 5703.00 | 0.800272 |
| SPLIT TN2 HP COOLING COIL | 0.310904 | 5681.79 | 0.800022 |
| SPLIT TS1 HP COOLING COIL | 0.325944 | 5932.13 | 0.800399 |
| SPLIT TS2 HP COOLING COIL | 0.324546 | 5911.00 | 0.800154 |
| Design Size Rated Air Flow Rate [m3/s] | Design Size Gross Rated Heating Capacity [W] | |
| SPLIT GSW HEATING COIL | 0.318135 | 5811.38 |
| SPLIT GNW HEATING COIL | 0.302480 | 5546.73 |
| SPLIT OFFICE HEATING COIL | 0.368100 | 6706.83 |
| SPLIT GNE HEATING COIL | 0.280767 | 5222.70 |
| SPLIT GN1 HEATING COIL | 0.245959 | 4668.56 |
| SPLIT GN2 HEATING COIL | 0.245562 | 4662.41 |
| SPLIT GS1 HEATING COIL | 0.266249 | 5025.49 |
| SPLIT GS2 HEATING COIL | 0.269108 | 5068.80 |
| SPLIT MSW HEATING COIL | 0.705021 | 12723.10 |
| SPLIT MNW HEATING COIL | 0.671528 | 12174.35 |
| SPLIT MSE HEATING COIL | 0.646921 | 11866.13 |
| SPLIT MNE HEATING COIL | 0.614042 | 11317.74 |
| SPLIT MN1 HEATING COIL | 0.546385 | 10244.58 |
| SPLIT MN2 HEATING COIL | 0.545363 | 10228.45 |
| SPLIT MS1 HEATING COIL | 0.582439 | 10851.74 |
| SPLIT MS2 HEATING COIL | 0.581496 | 10837.45 |
| SPLIT TSW HEATING COIL | 0.392115 | 6984.29 |
| SPLIT TNW HEATING COIL | 0.379559 | 6777.00 |
| SPLIT TSE HEATING COIL | 0.348850 | 6327.96 |
| SPLIT TNE HEATING COIL | 0.336334 | 6119.01 |
| SPLIT TN1 HEATING COIL | 0.312298 | 5703.00 |
| SPLIT TN2 HEATING COIL | 0.310904 | 5681.79 |
| SPLIT TS1 HEATING COIL | 0.325944 | 5932.13 |
| SPLIT TS2 HEATING COIL | 0.324546 | 5911.00 |
| Design Size Nominal Capacity [W] | |
| SPLIT GSW_SUPPHEATCOIL | 5811.38 |
| SPLIT GNW_SUPPHEATCOIL | 5546.73 |
| SPLIT OFFICE_SUPPHEATCOIL | 6706.83 |
| SPLIT GNE_SUPPHEATCOIL | 5222.70 |
| SPLIT GN1_SUPPHEATCOIL | 4668.56 |
| SPLIT GN2_SUPPHEATCOIL | 4662.41 |
| SPLIT GS1_SUPPHEATCOIL | 5025.49 |
| SPLIT GS2_SUPPHEATCOIL | 5068.80 |
| SPLIT MSW_SUPPHEATCOIL | 12723.10 |
| SPLIT MNW_SUPPHEATCOIL | 12174.35 |
| SPLIT MSE_SUPPHEATCOIL | 11866.13 |
| SPLIT MNE_SUPPHEATCOIL | 11317.74 |
| SPLIT MN1_SUPPHEATCOIL | 10244.58 |
| SPLIT MN2_SUPPHEATCOIL | 10228.45 |
| SPLIT MS1_SUPPHEATCOIL | 10851.74 |
| SPLIT MS2_SUPPHEATCOIL | 10837.45 |
| SPLIT TSW_SUPPHEATCOIL | 6984.29 |
| SPLIT TNW_SUPPHEATCOIL | 6777.00 |
| SPLIT TSE_SUPPHEATCOIL | 6327.96 |
| SPLIT TNE_SUPPHEATCOIL | 6119.01 |
| SPLIT TN1_SUPPHEATCOIL | 5703.00 |
| SPLIT TN2_SUPPHEATCOIL | 5681.79 |
| SPLIT TS1_SUPPHEATCOIL | 5932.13 |
| SPLIT TS2_SUPPHEATCOIL | 5911.00 |
| Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
| SWHSYS1 | 0.000113 | 0.013615 |
| Design Flow Rate [m3/s] | Design Power Consumption [W] | |
| SWHSYS1 PUMP | 0.000113 | 14.49 |
| Use Side Design Flow Rate [m3/s] | |
| SWHSYS1 WATER HEATER | 0.000113 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces| None |
| Possible Shadow Receivers | |
| G SWALL SWA | GWINDOW1 S SWA | |
| G WWALL SWA | GWINDOW1 W SWA | |
| G NWALL NWA | GWINDOW1 N NWA | |
| G WWALL NWA | GWINDOW1 W NWA | |
| G SWALL SEA | GWINDOW1 S SEA | |
| G EWALL SEA | GWINDOW1 E SEA | |
| G NWALL NEA | GWINDOW1 N NEA | |
| G EWALL NEA | GWINDOW1 E NEA | |
| G NWALL N1A | GWINDOW1 N N1A | |
| G NWALL N2A | GWINDOW1 N N2A | |
| G SWALL S1A | GWINDOW1 S S1A | |
| G SWALL S2A | GWINDOW1 S S2A | |
| M WWALL SWA | MWINDOW1 W SWA | |
| M SWALL SWA | MWINDOW1 S SWA | |
| M NWALL NWA | MWINDOW1 N NWA | |
| M WWALL NWA | MWINDOW1 W NWA | |
| M EWALL SEA | MWINDOW1 E SEA | |
| M SWALL SEA | MWINDOW1 S SEA | |
| M NWALL NEA | MWINDOW1 N NEA | |
| M EWALL NEA | MWINDOW1 E NEA | |
| M NWALL N1A | MWINDOW1 N N1A | |
| M NWALL N2A | MWINDOW1 N N2A | |
| M SWALL S1A | MWINDOW1 S S1A | |
| M SWALL S2A | MWINDOW1 S S2A | |
| T WWALL SWA | TWINDOW1 W SWA | |
| T SWALL SWA | TWINDOW1 S SWA | |
| T NWALL NWA | TWINDOW1 N NWA | |
| T WWALL NWA | TWINDOW1 W NWA | |
| T EWALL SEA | TWINDOW1 E SEA | |
| T SWALL SEA | TWINDOW1 S SEA | |
| T NWALL NEA | TWINDOW1 N NEA | |
| T EWALL NEA | TWINDOW1 E NEA | |
| T NWALL N1A | TWINDOW1 N N1A | |
| T NWALL N2A | TWINDOW1 N N2A | |
| T SWALL S1A | TWINDOW1 S S1A | |
| T SWALL S2A | TWINDOW1 S S2A | |
| T EWALL C | TWINDOW14 | |
| G EWALL C | ENTRANCE DOOR | |
| M EWALL C | MWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Time Not Meeting the Adaptive Comfort Models during Occupied Hours| ASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Version| Version ID | |
| 1 | 22.1 |
| #TimeSteps | Minutes per TimeStep {minutes} | |
| 1 | 6 | 10 |
| Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
| 1 | 1 | 20 | 2 | 8 |
| Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
| 1 | Yes | Yes | No | No | Yes | No |
| Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
| 1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
| Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
| 1 | 0.556 | 0.556 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 24.20 | 18.90 | 15.70 | 13.60 | 15.50 | 17.10 | 21.20 | 26.90 | 27.60 | 27.90 | 27.40 | 26.20 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Normal | Daylighting {dimensionless} | |
| 1 | 1.000 | 1.000 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
| 1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
| Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
| 1 | Tampa-MacDill AFB FL USA TMY3 WMO#=747880 | 27.85 | -82.52 | -5.00 | 8.00 | 101229 | 1.2032 |
| Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
| 1 | Correlation | NA | 21.85 | 14.30 | NA |
| Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
| 1 | ApartmentMidRise | 0.000 | City | 4.00000E-002 | 0.40000 | FullExterior | 25 | 6 |
| Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Value {Anisotropic} | |
| 1 | Anisotropic |
| Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
| 1 | ThirdOrderBackwardDifference |
| Simulation {Yes/No} | Carbon Dioxide Concentration | |
| 1 | No | N/A |
| Simulation {Yes/No} | Generic Contaminant Concentration | |
| 1 | No | N/A |
| Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
| 1 | No | N/A | N/A | N/A |
| Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
| 1 | RegulaFalsi |
| Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
| 1 | 0.330 | 460.000 | 6.500000E-003 |
| Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
| 1 | LowerLeftCorner | Clockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
| Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
| 1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
| Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
| 1 | 0 | 0 | 0 |
| Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
| 1 | 27 | 243 | 39 |
| Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
| 1 | G SW APARTMENT | 0.0 | 0.00 | 0.00 | 0.00 | 5.79 | 3.81 | 1.52 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 2 | G NW APARTMENT | 0.0 | 0.00 | 9.30 | 0.00 | 5.79 | 13.11 | 1.52 | 1 | 1 | 1 | 0.00 | 11.58 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 3 | OFFICE | 0.0 | 34.75 | 0.00 | 0.00 | 40.54 | 3.81 | 1.52 | 1 | 1 | 1 | 34.75 | 46.33 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 4 | G NE APARTMENT | 0.0 | 34.75 | 9.30 | 0.00 | 40.54 | 13.11 | 1.52 | 1 | 1 | 1 | 34.75 | 46.33 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 5 | G N1 APARTMENT | 0.0 | 11.58 | 9.30 | 0.00 | 17.37 | 13.11 | 1.52 | 1 | 1 | 1 | 11.58 | 23.16 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 6 | G N2 APARTMENT | 0.0 | 23.16 | 9.30 | 0.00 | 28.95 | 13.11 | 1.52 | 1 | 1 | 1 | 23.16 | 34.75 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 7 | G S1 APARTMENT | 0.0 | 11.58 | 0.00 | 0.00 | 17.37 | 3.81 | 1.52 | 1 | 1 | 1 | 11.58 | 23.16 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 8 | G S2 APARTMENT | 0.0 | 23.16 | 0.00 | 0.00 | 28.95 | 3.81 | 1.52 | 1 | 1 | 1 | 23.16 | 34.75 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 9 | M SW APARTMENT | 0.0 | 0.00 | 0.00 | 3.05 | 5.79 | 3.81 | 4.57 | 1 | 1 | 2 | 0.00 | 11.58 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 10 | M NW APARTMENT | 0.0 | 0.00 | 9.30 | 3.05 | 5.79 | 13.11 | 4.57 | 1 | 1 | 2 | 0.00 | 11.58 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 11 | M SE APARTMENT | 0.0 | 34.75 | 0.00 | 3.05 | 40.54 | 3.81 | 4.57 | 1 | 1 | 2 | 34.75 | 46.33 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 12 | M NE APARTMENT | 0.0 | 34.75 | 9.30 | 3.05 | 40.54 | 13.11 | 4.57 | 1 | 1 | 2 | 34.75 | 46.33 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 13 | M N1 APARTMENT | 0.0 | 11.58 | 9.30 | 3.05 | 17.37 | 13.11 | 4.57 | 1 | 1 | 2 | 11.58 | 23.16 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 14 | M N2 APARTMENT | 0.0 | 23.16 | 9.30 | 3.05 | 28.95 | 13.11 | 4.57 | 1 | 1 | 2 | 23.16 | 34.75 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 15 | M S1 APARTMENT | 0.0 | 11.58 | 0.00 | 3.05 | 17.37 | 3.81 | 4.57 | 1 | 1 | 2 | 11.58 | 23.16 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 16 | M S2 APARTMENT | 0.0 | 23.16 | 0.00 | 3.05 | 28.95 | 3.81 | 4.57 | 1 | 1 | 2 | 23.16 | 34.75 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 17 | T SW APARTMENT | 0.0 | 0.00 | 0.00 | 9.14 | 5.79 | 3.81 | 10.67 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 18 | T NW APARTMENT | 0.0 | 0.00 | 9.30 | 9.14 | 5.79 | 13.11 | 10.67 | 1 | 1 | 1 | 0.00 | 11.58 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 19 | T SE APARTMENT | 0.0 | 34.75 | 0.00 | 9.14 | 40.54 | 3.81 | 10.67 | 1 | 1 | 1 | 34.75 | 46.33 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 20 | T NE APARTMENT | 0.0 | 34.75 | 9.30 | 9.14 | 40.54 | 13.11 | 10.67 | 1 | 1 | 1 | 34.75 | 46.33 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 21 | T N1 APARTMENT | 0.0 | 11.58 | 9.30 | 9.14 | 17.37 | 13.11 | 10.67 | 1 | 1 | 1 | 11.58 | 23.16 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 22 | T N2 APARTMENT | 0.0 | 23.16 | 9.30 | 9.14 | 28.95 | 13.11 | 10.67 | 1 | 1 | 1 | 23.16 | 34.75 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 23 | T S1 APARTMENT | 0.0 | 11.58 | 0.00 | 9.14 | 17.37 | 3.81 | 10.67 | 1 | 1 | 1 | 11.58 | 23.16 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 24 | T S2 APARTMENT | 0.0 | 23.16 | 0.00 | 9.14 | 28.95 | 3.81 | 10.67 | 1 | 1 | 1 | 23.16 | 34.75 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 25 | T CORRIDOR | 0.0 | 0.00 | 7.62 | 9.14 | 23.16 | 8.46 | 10.67 | 1 | 1 | 1 | 0.00 | 46.33 | 7.62 | 9.30 | 9.14 | 12.19 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 9.10 | 1.11 | 12 | 1 | 0 | Yes |
| 26 | G CORRIDOR | 0.0 | 0.00 | 7.62 | 0.00 | 23.16 | 8.46 | 1.52 | 1 | 1 | 1 | 0.00 | 46.33 | 7.62 | 9.30 | 0.00 | 3.05 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 6.90 | 3.32 | 12 | 1 | 0 | Yes |
| 27 | M CORRIDOR | 0.0 | 0.00 | 7.62 | 3.05 | 23.16 | 8.46 | 4.57 | 1 | 1 | 2 | 0.00 | 46.33 | 7.62 | 9.30 | 3.05 | 6.10 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 9.10 | 1.11 | 12 | 1 | 0 | Yes |
| Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
| 1 | G SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 2 | G NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 3 | OFFICE | 88.25 | 4.7 | 18.581 | 5.382E-002 | 7.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 14.160 | No |
| 4 | G NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 5 | G N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 6 | G N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 7 | G S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 8 | G S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 9 | M SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 10 | M NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 11 | M SE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 12 | M NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 13 | M N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 14 | M N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 15 | M S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 16 | M S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 17 | T SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 18 | T NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 19 | T SE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 20 | T NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 21 | T N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 22 | T N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 23 | T S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 24 | T S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 25 | T CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 5.287 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.287 | No |
| 26 | G CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 5.287 | 515.392 | 0.000 | 0.000 | 0.000 | 0.000 | 520.679 | No |
| 27 | M CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 5.287 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.287 | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
| 1 | OCCUP_GSW | OCC_APT_SCH_WORKING_FAMILY | G SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 2 | OCCUP_GNW | OCC_APT_SCH_STAY_HOME_FAMILY | G NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 3 | OCCUP_OFFICE | OCC_OFF_W_SB_SCH | OFFICE | 88.25 | 4.7 | 4.7 | 5.382E-002 | 18.581 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 5 |
| 4 | OCCUP_GNE | OCC_APT_SCH_STAY_HOME_FAMILY | G NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 5 | OCCUP_GN1 | OCC_APT_SCH_STAY_HOME_FAMILY | G N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 6 | OCCUP_GN2 | OCC_APT_SCH_STAY_HOME_FAMILY | G N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 7 | OCCUP_GS1 | OCC_APT_SCH_WORKING_FAMILY | G S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 8 | OCCUP_GS2 | OCC_APT_SCH_WORKING_FAMILY | G S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 9 | OCCUP_MSW | OCC_APT_SCH_WORKING_FAMILY | M SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 10 | OCCUP_MNW | OCC_APT_SCH_STAY_HOME_FAMILY | M NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 11 | OCCUP_MSE | OCC_APT_SCH_WORKING_FAMILY | M SE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 12 | OCCUP_MNE | OCC_APT_SCH_STAY_HOME_FAMILY | M NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 13 | OCCUP_MN1 | OCC_APT_SCH_STAY_HOME_FAMILY | M N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 14 | OCCUP_MN2 | OCC_APT_SCH_STAY_HOME_FAMILY | M N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 15 | OCCUP_MS1 | OCC_APT_SCH_WORKING_FAMILY | M S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 16 | OCCUP_MS2 | OCC_APT_SCH_WORKING_FAMILY | M S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 17 | OCCUP_TSW | OCC_APT_SCH_WORKING_FAMILY | T SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 18 | OCCUP_TNW | OCC_APT_SCH_STAY_HOME_FAMILY | T NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 19 | OCCUP_TSE | OCC_APT_SCH_WORKING_FAMILY | T SE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 20 | OCCUP_TNE | OCC_APT_SCH_STAY_HOME_FAMILY | T NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 21 | OCCUP_TN1 | OCC_APT_SCH_STAY_HOME_FAMILY | T N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 22 | OCCUP_TN2 | OCC_APT_SCH_STAY_HOME_FAMILY | T N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 23 | OCCUP_TS1 | OCC_APT_SCH_WORKING_FAMILY | T S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 24 | OCCUP_TS2 | OCC_APT_SCH_WORKING_FAMILY | T S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 25 | OCCUP_T CORRIDOR | OCC_APT_SCH_CORRIDOR | T CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| 26 | OCCUP_G CORRIDOR | OCC_APT_SCH_CORRIDOR | G CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| 27 | OCCUP_M CORRIDOR | OCC_APT_SCH_CORRIDOR | M CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
| 1 | LIGHTING_HARDWIRED_GSW | LTG_SCH_APARTMENT_HARDWIRED | G SW APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 2 | LIGHTING_HARDWIRED_GNW | LTG_SCH_APARTMENT_HARDWIRED | G NW APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 3 | LIGHTING_HARDWIRED_OFFICE | LTG_SCH_OFFICE | OFFICE | 88.25 | 4.7 | 660.945 | 7.490 | 139.160 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 660.945 |
| 4 | LIGHTING_HARDWIRED_GNE | LTG_SCH_APARTMENT_HARDWIRED | G NE APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 5 | LIGHTING_HARDWIRED_GN1 | LTG_SCH_APARTMENT_HARDWIRED | G N1 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 6 | LIGHTING_HARDWIRED_GN2 | LTG_SCH_APARTMENT_HARDWIRED | G N2 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 7 | LIGHTING_HARDWIRED_GS1 | LTG_SCH_APARTMENT_HARDWIRED | G S1 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 8 | LIGHTING_HARDWIRED_GS2 | LTG_SCH_APARTMENT_HARDWIRED | G S2 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 9 | LIGHTING_HARDWIRED_MSW | LTG_SCH_APARTMENT_HARDWIRED | M SW APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 10 | LIGHTING_HARDWIRED_MNW | LTG_SCH_APARTMENT_HARDWIRED | M NW APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 11 | LIGHTING_HARDWIRED_MSE | LTG_SCH_APARTMENT_HARDWIRED | M SE APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 12 | LIGHTING_HARDWIRED_MNE | LTG_SCH_APARTMENT_HARDWIRED | M NE APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 13 | LIGHTING_HARDWIRED_MN1 | LTG_SCH_APARTMENT_HARDWIRED | M N1 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 14 | LIGHTING_HARDWIRED_MN2 | LTG_SCH_APARTMENT_HARDWIRED | M N2 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 15 | LIGHTING_HARDWIRED_MS1 | LTG_SCH_APARTMENT_HARDWIRED | M S1 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 16 | LIGHTING_HARDWIRED_MS2 | LTG_SCH_APARTMENT_HARDWIRED | M S2 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 17 | LIGHTING_HARDWIRED_TSW | LTG_SCH_APARTMENT_HARDWIRED | T SW APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 18 | LIGHTING_HARDWIRED_TNW | LTG_SCH_APARTMENT_HARDWIRED | T NW APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 19 | LIGHTING_HARDWIRED_TSE | LTG_SCH_APARTMENT_HARDWIRED | T SE APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 20 | LIGHTING_HARDWIRED_TNE | LTG_SCH_APARTMENT_HARDWIRED | T NE APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 21 | LIGHTING_HARDWIRED_TN1 | LTG_SCH_APARTMENT_HARDWIRED | T N1 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 22 | LIGHTING_HARDWIRED_TN2 | LTG_SCH_APARTMENT_HARDWIRED | T N2 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 23 | LIGHTING_HARDWIRED_TS1 | LTG_SCH_APARTMENT_HARDWIRED | T S1 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 24 | LIGHTING_HARDWIRED_TS2 | LTG_SCH_APARTMENT_HARDWIRED | T S2 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 25 | LIGHTING_HARDWIRED_GC | LTG_SCH_CORRIDOR | G CORRIDOR | 77.66 | 4.2 | 410.594 | 5.287 | 98.228 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 410.594 |
| 26 | LIGHTING_HARDWIRED_MC | LTG_SCH_CORRIDOR | M CORRIDOR | 77.66 | 4.2 | 410.594 | 5.287 | 98.228 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 410.594 |
| 27 | LIGHTING_HARDWIRED_TC | LTG_SCH_CORRIDOR | T CORRIDOR | 77.66 | 4.2 | 410.594 | 5.287 | 98.228 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 410.594 |
| 28 | LIGHTING_PLUGIN_GSW | LTG_SCH_APARTMENT_PLUGIN | G SW APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 29 | LIGHTING_PLUGIN_GNW | LTG_SCH_APARTMENT_PLUGIN | G NW APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 30 | LIGHTING_PLUGIN_GNE | LTG_SCH_APARTMENT_PLUGIN | G NE APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 31 | LIGHTING_PLUGIN_GN1 | LTG_SCH_APARTMENT_PLUGIN | G N1 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 32 | LIGHTING_PLUGIN_GN2 | LTG_SCH_APARTMENT_PLUGIN | G N2 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 33 | LIGHTING_PLUGIN_GS1 | LTG_SCH_APARTMENT_PLUGIN | G S1 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 34 | LIGHTING_PLUGIN_GS2 | LTG_SCH_APARTMENT_PLUGIN | G S2 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 35 | LIGHTING_PLUGIN_MSW | LTG_SCH_APARTMENT_PLUGIN | M SW APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 36 | LIGHTING_PLUGIN_MNW | LTG_SCH_APARTMENT_PLUGIN | M NW APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 37 | LIGHTING_PLUGIN_MSE | LTG_SCH_APARTMENT_PLUGIN | M SE APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 38 | LIGHTING_PLUGIN_MNE | LTG_SCH_APARTMENT_PLUGIN | M NE APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 39 | LIGHTING_PLUGIN_MN1 | LTG_SCH_APARTMENT_PLUGIN | M N1 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 40 | LIGHTING_PLUGIN_MN2 | LTG_SCH_APARTMENT_PLUGIN | M N2 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 41 | LIGHTING_PLUGIN_MS1 | LTG_SCH_APARTMENT_PLUGIN | M S1 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 42 | LIGHTING_PLUGIN_MS2 | LTG_SCH_APARTMENT_PLUGIN | M S2 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 43 | LIGHTING_PLUGIN_TSW | LTG_SCH_APARTMENT_PLUGIN | T SW APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 44 | LIGHTING_PLUGIN_TNW | LTG_SCH_APARTMENT_PLUGIN | T NW APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 45 | LIGHTING_PLUGIN_TSE | LTG_SCH_APARTMENT_PLUGIN | T SE APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 46 | LIGHTING_PLUGIN_TNE | LTG_SCH_APARTMENT_PLUGIN | T NE APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 47 | LIGHTING_PLUGIN_TN1 | LTG_SCH_APARTMENT_PLUGIN | T N1 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 48 | LIGHTING_PLUGIN_TN2 | LTG_SCH_APARTMENT_PLUGIN | T N2 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 49 | LIGHTING_PLUGIN_TS1 | LTG_SCH_APARTMENT_PLUGIN | T S1 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 50 | LIGHTING_PLUGIN_TS2 | LTG_SCH_APARTMENT_PLUGIN | T S2 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
| 1 | ELEVATOR_LIFT_RUNNING | ELEVATOR_RUNNING_SCH | G CORRIDOR | 77.66 | 4.2 | 38362.000 | 493.978 | 9177.512 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLift | 0.000 | 2585.215 |
| 2 | ELEVATOR_LIFT_STANDBY | ELEVATOR_STANDBY_SCH | G CORRIDOR | 77.66 | 4.2 | 1600.000 | 20.603 | 382.775 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLift | 1187.152 | 1600.000 |
| 3 | ELEVATORS_LIGHTS_FAN | ELEV_LIGHT_FAN_SCH_ADD_DF | G CORRIDOR | 77.66 | 4.2 | 63.000 | 0.811 | 15.072 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLightsFan | 3.150 | 31.500 |
| 4 | PLUG_GSW | EQP_APT_SCH | G SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 5 | PLUG_GNW | EQP_APT_SCH | G NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 6 | PLUG_OFFICE | EQP_OFF_SCH | OFFICE | 88.25 | 4.7 | 588.623 | 6.670 | 123.933 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 588.623 |
| 7 | PLUG_GNE | EQP_APT_SCH | G NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 8 | PLUG_GN1 | EQP_APT_SCH | G N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 9 | PLUG_GN2 | EQP_APT_SCH | G N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 10 | PLUG_GS1 | EQP_APT_SCH | G S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 11 | PLUG_GS2 | EQP_APT_SCH | G S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 12 | PLUG_MSW | EQP_APT_SCH | M SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 13 | PLUG_MNW | EQP_APT_SCH | M NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 14 | PLUG_MSE | EQP_APT_SCH | M SE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 15 | PLUG_MNE | EQP_APT_SCH | M NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 16 | PLUG_MN1 | EQP_APT_SCH | M N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 17 | PLUG_MN2 | EQP_APT_SCH | M N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 18 | PLUG_MS1 | EQP_APT_SCH | M S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 19 | PLUG_MS2 | EQP_APT_SCH | M S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 20 | PLUG_TSW | EQP_APT_SCH | T SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 21 | PLUG_TNW | EQP_APT_SCH | T NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 22 | PLUG_TSE | EQP_APT_SCH | T SE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 23 | PLUG_TNE | EQP_APT_SCH | T NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 24 | PLUG_TN1 | EQP_APT_SCH | T N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 25 | PLUG_TN2 | EQP_APT_SCH | T N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 26 | PLUG_TS1 | EQP_APT_SCH | T S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 27 | PLUG_TS2 | EQP_APT_SCH | T S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
| 1 | PolygonClipping | Periodic | 20 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
| Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
| 1 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | 0.9460 | 53912.0 | 11.449 | 0.4600 |
| Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
| 1 | G SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 2 | GWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 3 | G WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 4 | GWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 5 | G NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 6 | G EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 7 | G GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 8 | G CEILIN SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 9 | G INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 10 | G NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 11 | GWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 12 | G WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 13 | GWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 14 | G SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 15 | G EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 16 | G GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 17 | G CEILIN NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 18 | G INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 19 | G SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 20 | GWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 21 | G EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 22 | GWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 23 | G NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 24 | iz-G EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 25 | G GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 26 | G CEILIN SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 27 | G INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 28 | G NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 29 | GWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 30 | G EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 31 | GWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 32 | G SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 33 | iz-G EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 34 | G GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 35 | G CEILIN NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 36 | G INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 37 | G NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 38 | GWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 39 | G SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 40 | G EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 41 | iz-G EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 42 | G GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 43 | G CEILIN N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 44 | G INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 45 | G NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 46 | GWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 47 | G SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 48 | G EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 49 | iz-G EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 50 | G GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 51 | G CEILIN N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 52 | G INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 53 | G SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 54 | GWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 55 | G NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 56 | G EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 57 | iz-G EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 58 | G GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 59 | G CEILIN S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 60 | G INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 61 | G SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 62 | GWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 63 | G NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 64 | G EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 65 | iz-G EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 66 | G GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 67 | G CEILIN S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 68 | G INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 69 | M WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 70 | MWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 71 | M SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 72 | MWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 73 | M NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 74 | M EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 75 | M GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 76 | M CEILIN SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 77 | M INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 78 | M NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 79 | MWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 80 | M WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 81 | MWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 82 | M SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 83 | M EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 84 | M GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 85 | M CEILIN NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 86 | M INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 87 | M EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 88 | MWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 89 | M SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 90 | MWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 91 | M NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 92 | iz-M EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 93 | M GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 94 | M CEILIN SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 95 | M INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 96 | M NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 97 | MWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 98 | M EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 99 | MWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 100 | M SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 101 | iz-M EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 102 | M GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 103 | M CEILIN NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 104 | M INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 105 | M NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 106 | MWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 107 | M SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 108 | M EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 109 | iz-M EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 110 | M GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 111 | M CEILIN N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 112 | M INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 113 | M NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 114 | MWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 115 | M SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 116 | M EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 117 | iz-M EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 118 | M GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 119 | M CEILIN N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 120 | M INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 121 | M SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 122 | MWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 123 | M NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 124 | M EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 125 | iz-M EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 126 | M GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 127 | M CEILIN S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 128 | M INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 129 | M SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 130 | MWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 131 | M NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 132 | M EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 133 | iz-M EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 134 | M GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 135 | M CEILIN S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 136 | M INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 137 | T WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 138 | TWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 139 | T SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 140 | TWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 141 | T NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 142 | T EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 143 | T GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 144 | T ROOF SWA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 145 | T INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 146 | T NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 147 | TWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 148 | T WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 149 | TWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 150 | T SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 151 | T EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 152 | T GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 153 | T ROOF NWA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 154 | T INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 155 | T EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 156 | TWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 157 | T SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 158 | TWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 159 | T NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 160 | iz-T EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 161 | T GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 162 | T ROOF SEA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 163 | T INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 164 | T NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 165 | TWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 166 | T EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 167 | TWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 168 | T SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 169 | iz-T EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 170 | T GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 171 | T ROOF NEA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 172 | T INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 173 | T NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 174 | TWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 175 | T SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 176 | T EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 177 | iz-T EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 178 | T GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 179 | T ROOF N1A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 180 | T INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 181 | T NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 182 | TWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 183 | T SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 184 | T EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 185 | iz-T EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 186 | T GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 187 | T ROOF N2A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 188 | T INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 189 | T SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 190 | TWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 191 | T NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 192 | T EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 193 | iz-T EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 194 | T GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 195 | T ROOF S1A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 196 | T INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 197 | T SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 198 | TWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 199 | T NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 200 | T EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 201 | iz-T EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 202 | T GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 203 | T ROOF S2A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 204 | T INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 205 | T WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 206 | T EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 207 | TWINDOW14 | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 2 | No | No |
| 208 | iz-T NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 209 | iz-T NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 210 | iz-T NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 211 | iz-T NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 212 | iz-T SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 213 | iz-T SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 214 | iz-T SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 215 | iz-T SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 216 | T FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 217 | T ROOF C | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 218 | G WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 4 | No | No |
| 219 | G EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 4 | No | No |
| 220 | ENTRANCE DOOR | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 1 | No | No |
| 221 | iz-G NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 222 | iz-G NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 223 | iz-G NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 224 | iz-G NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 225 | iz-G SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 226 | iz-G SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 227 | iz-G SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 228 | iz-G SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 229 | G FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 230 | G CEILING C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 231 | M WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 4 | No | No |
| 232 | M EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 233 | MWINDOW14 | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 2 | No | No |
| 234 | iz-M NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 235 | iz-M NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 236 | iz-M NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 237 | iz-M NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 238 | iz-M SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 239 | iz-M SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 240 | iz-M SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 241 | iz-M SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 242 | M FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 243 | M CEILING C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
| 1 | INFIL_GSW | INF_APT_SCH | G SW APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 2 | INFIL_GNW | INF_APT_SCH | G NW APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 3 | INFIL_OFFICE | INF_OFF_SCH | OFFICE | 88.25 | 4.7 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 4 | INFIL_GNE | INF_APT_SCH | G NE APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 5 | INFIL_GN1 | INF_APT_SCH | G N1 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 6 | INFIL_GN2 | INF_APT_SCH | G N2 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 7 | INFIL_GS1 | INF_APT_SCH | G S1 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 8 | INFIL_GS2 | INF_APT_SCH | G S2 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 9 | INFIL_MSW | INF_APT_SCH | M SW APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 10 | INFIL_MNW | INF_APT_SCH | M NW APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 11 | INFIL_MSE | INF_APT_SCH | M SE APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 12 | INFIL_MNE | INF_APT_SCH | M NE APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 13 | INFIL_MN1 | INF_APT_SCH | M N1 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 14 | INFIL_MN2 | INF_APT_SCH | M N2 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 15 | INFIL_MS1 | INF_APT_SCH | M S1 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 16 | INFIL_MS2 | INF_APT_SCH | M S2 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 17 | INFIL_SW | INF_APT_SCH | T SW APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 1.022E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 18 | INFIL_NW | INF_APT_SCH | T NW APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 1.022E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 19 | INFIL_SE | INF_APT_SCH | T SE APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 1.022E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 20 | INFIL_NE | INF_APT_SCH | T NE APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 1.022E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 21 | INFIL_TN1 | INF_APT_SCH | T N1 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 7.323E-005 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 22 | INFIL_TN2 | INF_APT_SCH | T N2 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 7.323E-005 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 23 | INFIL_TS1 | INF_APT_SCH | T S1 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 7.323E-005 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 24 | INFIL_TS2 | INF_APT_SCH | T S2 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 7.323E-005 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 25 | INFIL_GC | INF_COR_SCH | G CORRIDOR | 77.66 | 4.2 | 2.619E-003 | 3.372E-005 | 2.563E-004 | 3.983E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| 26 | DOOR_INFIL_GC | INFIL_DOOR_OPENING_SCH | G CORRIDOR | 77.66 | 4.2 | 0.521 | 6.703E-003 | 5.094E-002 | 7.917 | 1.000 | 0.000 | 0.000 | 0.000 |
| 27 | INFIL_MC | INF_COR_SCH | M CORRIDOR | 77.66 | 4.2 | 2.619E-003 | 3.372E-005 | 2.563E-004 | 3.983E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| 28 | INFIL_TC | INF_COR_SCH | T CORRIDOR | 77.66 | 4.2 | 2.619E-003 | 3.372E-005 | 2.980E-005 | 3.983E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
| 1 | G SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 2 | G NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 3 | G NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 4 | G N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 5 | G N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 6 | G S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 7 | G S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 8 | M SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 9 | M NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 10 | M SE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M SE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 11 | M NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 12 | M N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 13 | M N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 14 | M S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 15 | M S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 16 | T SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 17 | T NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 18 | T SE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T SE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 19 | T NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 20 | T N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 21 | T N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 22 | T S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 23 | T S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| Simple | |
| 1 | Simple |
| Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
| 1 | G SW APARTMENT | Mixing/Well-Stirred |
| 2 | G NW APARTMENT | Mixing/Well-Stirred |
| 3 | OFFICE | Mixing/Well-Stirred |
| 4 | G NE APARTMENT | Mixing/Well-Stirred |
| 5 | G N1 APARTMENT | Mixing/Well-Stirred |
| 6 | G N2 APARTMENT | Mixing/Well-Stirred |
| 7 | G S1 APARTMENT | Mixing/Well-Stirred |
| 8 | G S2 APARTMENT | Mixing/Well-Stirred |
| 9 | M SW APARTMENT | Mixing/Well-Stirred |
| 10 | M NW APARTMENT | Mixing/Well-Stirred |
| 11 | M SE APARTMENT | Mixing/Well-Stirred |
| 12 | M NE APARTMENT | Mixing/Well-Stirred |
| 13 | M N1 APARTMENT | Mixing/Well-Stirred |
| 14 | M N2 APARTMENT | Mixing/Well-Stirred |
| 15 | M S1 APARTMENT | Mixing/Well-Stirred |
| 16 | M S2 APARTMENT | Mixing/Well-Stirred |
| 17 | T SW APARTMENT | Mixing/Well-Stirred |
| 18 | T NW APARTMENT | Mixing/Well-Stirred |
| 19 | T SE APARTMENT | Mixing/Well-Stirred |
| 20 | T NE APARTMENT | Mixing/Well-Stirred |
| 21 | T N1 APARTMENT | Mixing/Well-Stirred |
| 22 | T N2 APARTMENT | Mixing/Well-Stirred |
| 23 | T S1 APARTMENT | Mixing/Well-Stirred |
| 24 | T S2 APARTMENT | Mixing/Well-Stirred |
| 25 | T CORRIDOR | Mixing/Well-Stirred |
| 26 | G CORRIDOR | Mixing/Well-Stirred |
| 27 | M CORRIDOR | Mixing/Well-Stirred |
| No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
| 1 | NoMultizoneOrDistribution |
| Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
| 1 | 1.000 | 1.000 | 1.000 | 1.000 |
| Value | |
| 1 | 6 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.2000 |
| 2 | Zone G SW APARTMENT | 1.2000 |
| 3 | Zone G NW APARTMENT | 1.2000 |
| 4 | Zone OFFICE | 1.2000 |
| 5 | Zone G NE APARTMENT | 1.2000 |
| 6 | Zone G N1 APARTMENT | 1.2000 |
| 7 | Zone G N2 APARTMENT | 1.2000 |
| 8 | Zone G S1 APARTMENT | 1.2000 |
| 9 | Zone G S2 APARTMENT | 1.2000 |
| 10 | Zone M SW APARTMENT | 1.2000 |
| 11 | Zone M NW APARTMENT | 1.2000 |
| 12 | Zone M SE APARTMENT | 1.2000 |
| 13 | Zone M NE APARTMENT | 1.2000 |
| 14 | Zone M N1 APARTMENT | 1.2000 |
| 15 | Zone M N2 APARTMENT | 1.2000 |
| 16 | Zone M S1 APARTMENT | 1.2000 |
| 17 | Zone M S2 APARTMENT | 1.2000 |
| 18 | Zone T SW APARTMENT | 1.2000 |
| 19 | Zone T NW APARTMENT | 1.2000 |
| 20 | Zone T SE APARTMENT | 1.2000 |
| 21 | Zone T NE APARTMENT | 1.2000 |
| 22 | Zone T N1 APARTMENT | 1.2000 |
| 23 | Zone T N2 APARTMENT | 1.2000 |
| 24 | Zone T S1 APARTMENT | 1.2000 |
| 25 | Zone T S2 APARTMENT | 1.2000 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.2000 |
| 2 | Zone G SW APARTMENT | 1.2000 |
| 3 | Zone G NW APARTMENT | 1.2000 |
| 4 | Zone OFFICE | 1.2000 |
| 5 | Zone G NE APARTMENT | 1.2000 |
| 6 | Zone G N1 APARTMENT | 1.2000 |
| 7 | Zone G N2 APARTMENT | 1.2000 |
| 8 | Zone G S1 APARTMENT | 1.2000 |
| 9 | Zone G S2 APARTMENT | 1.2000 |
| 10 | Zone M SW APARTMENT | 1.2000 |
| 11 | Zone M NW APARTMENT | 1.2000 |
| 12 | Zone M SE APARTMENT | 1.2000 |
| 13 | Zone M NE APARTMENT | 1.2000 |
| 14 | Zone M N1 APARTMENT | 1.2000 |
| 15 | Zone M N2 APARTMENT | 1.2000 |
| 16 | Zone M S1 APARTMENT | 1.2000 |
| 17 | Zone M S2 APARTMENT | 1.2000 |
| 18 | Zone T SW APARTMENT | 1.2000 |
| 19 | Zone T NW APARTMENT | 1.2000 |
| 20 | Zone T SE APARTMENT | 1.2000 |
| 21 | Zone T NE APARTMENT | 1.2000 |
| 22 | Zone T N1 APARTMENT | 1.2000 |
| 23 | Zone T N2 APARTMENT | 1.2000 |
| 24 | Zone T S1 APARTMENT | 1.2000 |
| 25 | Zone T S2 APARTMENT | 1.2000 |
| Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
| 1 | G SW APARTMENT | Cooling | 3760.26677 | 4512.32012 | 0.26511 | 0.31814 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 2 | G SW APARTMENT | Heating | 656.13976 | 787.36772 | 2.82962E-002 | 3.39554E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 3 | G NW APARTMENT | Cooling | 3579.22266 | 4295.06719 | 0.25207 | 0.30248 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 4 | G NW APARTMENT | Heating | 536.07059 | 643.28471 | 2.31186E-002 | 2.77423E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 5 | OFFICE | Cooling | 4177.27880 | 5012.73456 | 0.30675 | 0.36810 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 09:20:00 | 30.00267 | 1.65290E-002 | 88.24927 | 4.74953 | 3.81060E-002 | 0.00000 |
| 6 | OFFICE | Heating | 1048.98916 | 1258.78699 | 4.52381E-002 | 5.42857E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | 4.60000 | 5.25715E-003 | 88.24927 | 4.74953 | 3.81060E-002 | 0.00000 |
| 7 | G NE APARTMENT | Cooling | 3328.97526 | 3994.77032 | 0.23397 | 0.28077 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 8 | G NE APARTMENT | Heating | 537.03659 | 644.44390 | 2.31603E-002 | 2.77923E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 9 | G N1 APARTMENT | Cooling | 2927.28368 | 3512.74042 | 0.20497 | 0.24596 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 10 | G N1 APARTMENT | Heating | 241.70465 | 290.04558 | 1.04238E-002 | 2.59546E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 11 | G N2 APARTMENT | Cooling | 2922.71782 | 3507.26138 | 0.20464 | 0.24556 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 12 | G N2 APARTMENT | Heating | 241.73154 | 290.07785 | 1.04250E-002 | 2.59546E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 13 | G S1 APARTMENT | Cooling | 3162.37201 | 3794.84641 | 0.22187 | 0.26625 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 14 | G S1 APARTMENT | Heating | 360.86192 | 433.03431 | 1.55623E-002 | 2.59546E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 15 | G S2 APARTMENT | Cooling | 3195.10464 | 3834.12557 | 0.22426 | 0.26911 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 16 | G S2 APARTMENT | Heating | 372.05542 | 446.46650 | 1.60450E-002 | 2.59546E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 17 | M SW APARTMENT | Cooling | 8311.92124 | 9974.30548 | 0.58752 | 0.70502 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 18 | M SW APARTMENT | Heating | 1393.31398 | 1671.97677 | 6.00868E-002 | 7.21042E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 19 | M NW APARTMENT | Cooling | 7927.77469 | 9513.32962 | 0.55961 | 0.67153 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 20 | M NW APARTMENT | Heating | 1120.13329 | 1344.15995 | 4.83067E-002 | 5.79681E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 21 | M SE APARTMENT | Cooling | 7644.83679 | 9173.80415 | 0.53910 | 0.64692 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 22 | M SE APARTMENT | Heating | 1395.68987 | 1674.82784 | 6.01893E-002 | 7.22271E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 23 | M NE APARTMENT | Cooling | 7263.58839 | 8716.30607 | 0.51170 | 0.61404 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 24 | M NE APARTMENT | Heating | 1122.62586 | 1347.15103 | 4.84142E-002 | 5.80971E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 25 | M N1 APARTMENT | Cooling | 6483.89169 | 7780.67003 | 0.45532 | 0.54638 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 26 | M N1 APARTMENT | Heating | 418.61491 | 502.33790 | 1.80532E-002 | 5.19091E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 27 | M N2 APARTMENT | Cooling | 6472.14429 | 7766.57315 | 0.45447 | 0.54536 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 28 | M N2 APARTMENT | Heating | 418.67679 | 502.41215 | 1.80559E-002 | 5.19091E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 29 | M S1 APARTMENT | Cooling | 6898.48029 | 8278.17635 | 0.48537 | 0.58244 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 30 | M S1 APARTMENT | Heating | 680.65079 | 816.78095 | 2.93532E-002 | 5.19091E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 31 | M S2 APARTMENT | Cooling | 6887.61487 | 8265.13785 | 0.48458 | 0.58150 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 32 | M S2 APARTMENT | Heating | 680.70981 | 816.85178 | 2.93558E-002 | 5.19091E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 33 | T SW APARTMENT | Cooling | 4614.48339 | 5537.38007 | 0.32676 | 0.39212 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 34 | T SW APARTMENT | Heating | 1305.26012 | 1566.31214 | 5.62893E-002 | 6.75471E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 35 | T NW APARTMENT | Cooling | 4469.39948 | 5363.27937 | 0.31630 | 0.37956 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 36 | T NW APARTMENT | Heating | 1158.04158 | 1389.64990 | 4.99414E-002 | 5.99297E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 37 | T SE APARTMENT | Cooling | 4115.28128 | 4938.33753 | 0.29071 | 0.34885 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 38 | T SE APARTMENT | Heating | 1306.43649 | 1567.72379 | 5.63400E-002 | 6.76080E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 39 | T NE APARTMENT | Cooling | 3971.30593 | 4765.56712 | 0.28028 | 0.33633 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 40 | T NE APARTMENT | Heating | 1159.30853 | 1391.17023 | 4.99960E-002 | 5.99953E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 41 | T N1 APARTMENT | Cooling | 3695.44836 | 4434.53803 | 0.26025 | 0.31230 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 42 | T N1 APARTMENT | Heating | 767.97894 | 921.57472 | 3.31199E-002 | 3.97438E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 43 | T N2 APARTMENT | Cooling | 3679.46841 | 4415.36209 | 0.25909 | 0.31090 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 44 | T N2 APARTMENT | Heating | 768.01482 | 921.61778 | 3.31214E-002 | 3.97457E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 45 | T S1 APARTMENT | Cooling | 3852.01046 | 4622.41255 | 0.27162 | 0.32594 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 46 | T S1 APARTMENT | Heating | 915.20551 | 1098.24662 | 3.94684E-002 | 4.73621E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 47 | T S2 APARTMENT | Cooling | 3835.95855 | 4603.15027 | 0.27045 | 0.32455 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 30.81900 | 1.65306E-002 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 48 | T S2 APARTMENT | Heating | 915.23852 | 1098.28623 | 3.94698E-002 | 4.73638E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 4.60000 | 5.25715E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
| 1 | SPLIT GSW | Cooling | Sensible | 4534.67 | 0.31814 | 0.31814 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 2 | SPLIT GSW | Heating | Sensible | 1293.65 | 3.39554E-002 | 3.39554E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 |
| 3 | SPLIT GNW | Cooling | Sensible | 4320.33 | 0.30248 | 0.30248 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 4 | SPLIT GNW | Heating | Sensible | 1151.68 | 2.77423E-002 | 2.77423E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 |
| 5 | SPLIT OFFICE | Cooling | Sensible | 5220.90 | 0.36810 | 0.36810 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 6 | SPLIT OFFICE | Heating | Sensible | 2000.61 | 5.42857E-002 | 5.42857E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 |
| 7 | SPLIT GNE | Cooling | Sensible | 4023.14 | 0.28077 | 0.28077 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 8 | SPLIT GNE | Heating | Sensible | 1152.82 | 2.77923E-002 | 2.77923E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 |
| 9 | SPLIT GN1 | Cooling | Sensible | 3544.78 | 0.24596 | 0.24596 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 10 | SPLIT GN1 | Heating | Sensible | 1110.83 | 2.59546E-002 | 2.59546E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:20:00 |
| 11 | SPLIT GN2 | Cooling | Sensible | 3539.32 | 0.24556 | 0.24556 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 12 | SPLIT GN2 | Heating | Sensible | 1110.83 | 2.59546E-002 | 2.59546E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 13 | SPLIT GS1 | Cooling | Sensible | 3824.61 | 0.26625 | 0.26625 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 14 | SPLIT GS1 | Heating | Sensible | 1110.83 | 2.59546E-002 | 2.59546E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 15 | SPLIT GS2 | Cooling | Sensible | 3863.55 | 0.26911 | 0.26911 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 16 | SPLIT GS2 | Heating | Sensible | 1110.83 | 2.59546E-002 | 2.59546E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 17 | SPLIT MSW | Cooling | Sensible | 10009.70 | 0.70502 | 0.70502 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 18 | SPLIT MSW | Heating | Sensible | 2683.13 | 7.21042E-002 | 7.21042E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 19 | SPLIT MNW | Cooling | Sensible | 9552.57 | 0.67153 | 0.67153 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 20 | SPLIT MNW | Heating | Sensible | 2360.11 | 5.79681E-002 | 5.79681E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 21 | SPLIT MSE | Cooling | Sensible | 9215.93 | 0.64692 | 0.64692 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 22 | SPLIT MSE | Heating | Sensible | 2685.94 | 7.22271E-002 | 7.22271E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 23 | SPLIT MNE | Cooling | Sensible | 8765.25 | 0.61404 | 0.61404 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 24 | SPLIT MNE | Heating | Sensible | 2363.06 | 5.80971E-002 | 5.80971E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 25 | SPLIT MN1 | Cooling | Sensible | 7839.55 | 0.54638 | 0.54638 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 26 | SPLIT MN1 | Heating | Sensible | 2221.66 | 5.19091E-002 | 5.19091E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 27 | SPLIT MN2 | Cooling | Sensible | 7825.53 | 0.54536 | 0.54536 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 28 | SPLIT MN2 | Heating | Sensible | 2221.66 | 5.19091E-002 | 5.19091E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 29 | SPLIT MS1 | Cooling | Sensible | 8332.41 | 0.58244 | 0.58244 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 30 | SPLIT MS1 | Heating | Sensible | 2221.66 | 5.19091E-002 | 5.19091E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 31 | SPLIT MS2 | Cooling | Sensible | 8319.51 | 0.58150 | 0.58150 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 32 | SPLIT MS2 | Heating | Sensible | 2221.66 | 5.19091E-002 | 5.19091E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 33 | SPLIT TSW | Cooling | Sensible | 5548.04 | 0.39212 | 0.39212 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 34 | SPLIT TSW | Heating | Sensible | 2061.25 | 6.75471E-002 | 6.75471E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 35 | SPLIT TNW | Cooling | Sensible | 5376.33 | 0.37956 | 0.37956 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 36 | SPLIT TNW | Heating | Sensible | 1887.17 | 5.99297E-002 | 5.99297E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 37 | SPLIT TSE | Cooling | Sensible | 4956.56 | 0.34885 | 0.34885 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 38 | SPLIT TSE | Heating | Sensible | 2062.64 | 6.76080E-002 | 6.76080E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 39 | SPLIT TNE | Cooling | Sensible | 4785.62 | 0.33633 | 0.33633 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 40 | SPLIT TNE | Heating | Sensible | 1888.67 | 5.99953E-002 | 5.99953E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 41 | SPLIT TN1 | Cooling | Sensible | 4457.66 | 0.31230 | 0.31230 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 42 | SPLIT TN1 | Heating | Sensible | 1425.92 | 3.97438E-002 | 3.97438E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 43 | SPLIT TN2 | Cooling | Sensible | 4438.64 | 0.31090 | 0.31090 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 44 | SPLIT TN2 | Heating | Sensible | 1425.96 | 3.97457E-002 | 3.97457E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 45 | SPLIT TS1 | Cooling | Sensible | 4643.89 | 0.32594 | 0.32594 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 46 | SPLIT TS1 | Heating | Sensible | 1600.00 | 4.73621E-002 | 4.73621E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 47 | SPLIT TS2 | Cooling | Sensible | 4624.81 | 0.32455 | 0.32455 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
| 48 | SPLIT TS2 | Heating | Sensible | 1600.04 | 4.73638E-002 | 4.73638E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| Component Type | Component Name | Input Field Description | Value | |
| 1 | ZoneHVAC:EnergyRecoveryVentilator | G SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 2 | ZoneHVAC:EnergyRecoveryVentilator | G SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 3 | Fan:OnOff | G SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 4 | Fan:OnOff | G SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 5 | HeatExchanger:AirToAir:SensibleAndLatent | G SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 6 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.31814 |
| 7 | ZoneHVAC:EnergyRecoveryVentilator | G NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 8 | ZoneHVAC:EnergyRecoveryVentilator | G NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 9 | Fan:OnOff | G NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 10 | Fan:OnOff | G NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 11 | HeatExchanger:AirToAir:SensibleAndLatent | G NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 12 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.30248 |
| 13 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | OFFICE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.36810 |
| 14 | ZoneHVAC:EnergyRecoveryVentilator | G NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 15 | ZoneHVAC:EnergyRecoveryVentilator | G NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 16 | Fan:OnOff | G NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 17 | Fan:OnOff | G NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 18 | HeatExchanger:AirToAir:SensibleAndLatent | G NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 19 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.28077 |
| 20 | ZoneHVAC:EnergyRecoveryVentilator | G N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 21 | ZoneHVAC:EnergyRecoveryVentilator | G N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 22 | Fan:OnOff | G N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 23 | Fan:OnOff | G N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 24 | HeatExchanger:AirToAir:SensibleAndLatent | G N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 25 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.24596 |
| 26 | ZoneHVAC:EnergyRecoveryVentilator | G N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 27 | ZoneHVAC:EnergyRecoveryVentilator | G N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 28 | Fan:OnOff | G N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 29 | Fan:OnOff | G N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 30 | HeatExchanger:AirToAir:SensibleAndLatent | G N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 31 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.24556 |
| 32 | ZoneHVAC:EnergyRecoveryVentilator | G S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 33 | ZoneHVAC:EnergyRecoveryVentilator | G S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 34 | Fan:OnOff | G S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 35 | Fan:OnOff | G S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 36 | HeatExchanger:AirToAir:SensibleAndLatent | G S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 37 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.26625 |
| 38 | ZoneHVAC:EnergyRecoveryVentilator | G S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 39 | ZoneHVAC:EnergyRecoveryVentilator | G S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 40 | Fan:OnOff | G S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 41 | Fan:OnOff | G S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 42 | HeatExchanger:AirToAir:SensibleAndLatent | G S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 43 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.26911 |
| 44 | ZoneHVAC:EnergyRecoveryVentilator | M SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 45 | ZoneHVAC:EnergyRecoveryVentilator | M SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 46 | Fan:OnOff | M SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 47 | Fan:OnOff | M SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 48 | HeatExchanger:AirToAir:SensibleAndLatent | M SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 49 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.70502 |
| 50 | ZoneHVAC:EnergyRecoveryVentilator | M NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 51 | ZoneHVAC:EnergyRecoveryVentilator | M NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 52 | Fan:OnOff | M NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 53 | Fan:OnOff | M NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 54 | HeatExchanger:AirToAir:SensibleAndLatent | M NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 55 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.67153 |
| 56 | ZoneHVAC:EnergyRecoveryVentilator | M SE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 57 | ZoneHVAC:EnergyRecoveryVentilator | M SE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 58 | Fan:OnOff | M SE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 59 | Fan:OnOff | M SE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 60 | HeatExchanger:AirToAir:SensibleAndLatent | M SE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 61 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M SE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.64692 |
| 62 | ZoneHVAC:EnergyRecoveryVentilator | M NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 63 | ZoneHVAC:EnergyRecoveryVentilator | M NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 64 | Fan:OnOff | M NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 65 | Fan:OnOff | M NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 66 | HeatExchanger:AirToAir:SensibleAndLatent | M NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 67 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.61404 |
| 68 | ZoneHVAC:EnergyRecoveryVentilator | M N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 69 | ZoneHVAC:EnergyRecoveryVentilator | M N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 70 | Fan:OnOff | M N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 71 | Fan:OnOff | M N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 72 | HeatExchanger:AirToAir:SensibleAndLatent | M N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 73 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.54638 |
| 74 | ZoneHVAC:EnergyRecoveryVentilator | M N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 75 | ZoneHVAC:EnergyRecoveryVentilator | M N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 76 | Fan:OnOff | M N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 77 | Fan:OnOff | M N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 78 | HeatExchanger:AirToAir:SensibleAndLatent | M N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 79 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.54536 |
| 80 | ZoneHVAC:EnergyRecoveryVentilator | M S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 81 | ZoneHVAC:EnergyRecoveryVentilator | M S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 82 | Fan:OnOff | M S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 83 | Fan:OnOff | M S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 84 | HeatExchanger:AirToAir:SensibleAndLatent | M S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 85 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.58244 |
| 86 | ZoneHVAC:EnergyRecoveryVentilator | M S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 87 | ZoneHVAC:EnergyRecoveryVentilator | M S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 88 | Fan:OnOff | M S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 89 | Fan:OnOff | M S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 90 | HeatExchanger:AirToAir:SensibleAndLatent | M S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 91 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.58150 |
| 92 | ZoneHVAC:EnergyRecoveryVentilator | T SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 93 | ZoneHVAC:EnergyRecoveryVentilator | T SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 94 | Fan:OnOff | T SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 95 | Fan:OnOff | T SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 96 | HeatExchanger:AirToAir:SensibleAndLatent | T SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 97 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.39212 |
| 98 | ZoneHVAC:EnergyRecoveryVentilator | T NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 99 | ZoneHVAC:EnergyRecoveryVentilator | T NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 100 | Fan:OnOff | T NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 101 | Fan:OnOff | T NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 102 | HeatExchanger:AirToAir:SensibleAndLatent | T NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 103 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.37956 |
| 104 | ZoneHVAC:EnergyRecoveryVentilator | T SE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 105 | ZoneHVAC:EnergyRecoveryVentilator | T SE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 106 | Fan:OnOff | T SE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 107 | Fan:OnOff | T SE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 108 | HeatExchanger:AirToAir:SensibleAndLatent | T SE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 109 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T SE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.34885 |
| 110 | ZoneHVAC:EnergyRecoveryVentilator | T NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 111 | ZoneHVAC:EnergyRecoveryVentilator | T NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 112 | Fan:OnOff | T NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 113 | Fan:OnOff | T NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 114 | HeatExchanger:AirToAir:SensibleAndLatent | T NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 115 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.33633 |
| 116 | ZoneHVAC:EnergyRecoveryVentilator | T N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 117 | ZoneHVAC:EnergyRecoveryVentilator | T N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 118 | Fan:OnOff | T N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 119 | Fan:OnOff | T N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 120 | HeatExchanger:AirToAir:SensibleAndLatent | T N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 121 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.31230 |
| 122 | ZoneHVAC:EnergyRecoveryVentilator | T N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 123 | ZoneHVAC:EnergyRecoveryVentilator | T N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 124 | Fan:OnOff | T N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 125 | Fan:OnOff | T N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 126 | HeatExchanger:AirToAir:SensibleAndLatent | T N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 127 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.31090 |
| 128 | ZoneHVAC:EnergyRecoveryVentilator | T S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 129 | ZoneHVAC:EnergyRecoveryVentilator | T S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 130 | Fan:OnOff | T S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 131 | Fan:OnOff | T S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 132 | HeatExchanger:AirToAir:SensibleAndLatent | T S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 133 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.32594 |
| 134 | ZoneHVAC:EnergyRecoveryVentilator | T S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 135 | ZoneHVAC:EnergyRecoveryVentilator | T S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 136 | Fan:OnOff | T S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 137 | Fan:OnOff | T S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 138 | HeatExchanger:AirToAir:SensibleAndLatent | T S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 139 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.32455 |
| 140 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.31814 |
| 141 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.31814 |
| 142 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.31814 |
| 143 | AirLoopHVAC | SPLIT GSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.31814 |
| 144 | AirLoopHVAC | SPLIT GSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.31814 |
| 145 | AirLoopHVAC | SPLIT GSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.31814 |
| 146 | AirLoopHVAC | SPLIT GSW | User Heating Air Flow Ratio [] | 1.00000 |
| 147 | AirLoopHVAC | SPLIT GSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 148 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.30248 |
| 149 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.30248 |
| 150 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.30248 |
| 151 | AirLoopHVAC | SPLIT GNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.30248 |
| 152 | AirLoopHVAC | SPLIT GNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.30248 |
| 153 | AirLoopHVAC | SPLIT GNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.30248 |
| 154 | AirLoopHVAC | SPLIT GNW | User Heating Air Flow Ratio [] | 1.00000 |
| 155 | AirLoopHVAC | SPLIT GNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 156 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.36810 |
| 157 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.36810 |
| 158 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.36810 |
| 159 | AirLoopHVAC | SPLIT OFFICE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.36810 |
| 160 | AirLoopHVAC | SPLIT OFFICE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.36810 |
| 161 | AirLoopHVAC | SPLIT OFFICE | Adjusted Main Design Air Flow Rate [m3/s] | 0.36810 |
| 162 | AirLoopHVAC | SPLIT OFFICE | User Heating Air Flow Ratio [] | 1.00000 |
| 163 | AirLoopHVAC | SPLIT OFFICE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 164 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.28077 |
| 165 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.28077 |
| 166 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.28077 |
| 167 | AirLoopHVAC | SPLIT GNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.28077 |
| 168 | AirLoopHVAC | SPLIT GNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.28077 |
| 169 | AirLoopHVAC | SPLIT GNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.28077 |
| 170 | AirLoopHVAC | SPLIT GNE | User Heating Air Flow Ratio [] | 1.00000 |
| 171 | AirLoopHVAC | SPLIT GNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 172 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.24596 |
| 173 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.24596 |
| 174 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.24596 |
| 175 | AirLoopHVAC | SPLIT GN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.24596 |
| 176 | AirLoopHVAC | SPLIT GN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.24596 |
| 177 | AirLoopHVAC | SPLIT GN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.24596 |
| 178 | AirLoopHVAC | SPLIT GN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 179 | AirLoopHVAC | SPLIT GN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 180 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.24556 |
| 181 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.24556 |
| 182 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.24556 |
| 183 | AirLoopHVAC | SPLIT GN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.24556 |
| 184 | AirLoopHVAC | SPLIT GN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.24556 |
| 185 | AirLoopHVAC | SPLIT GN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.24556 |
| 186 | AirLoopHVAC | SPLIT GN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 187 | AirLoopHVAC | SPLIT GN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 188 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.26625 |
| 189 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.26625 |
| 190 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.26625 |
| 191 | AirLoopHVAC | SPLIT GS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.26625 |
| 192 | AirLoopHVAC | SPLIT GS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.26625 |
| 193 | AirLoopHVAC | SPLIT GS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.26625 |
| 194 | AirLoopHVAC | SPLIT GS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 195 | AirLoopHVAC | SPLIT GS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 196 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.26911 |
| 197 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.26911 |
| 198 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.26911 |
| 199 | AirLoopHVAC | SPLIT GS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.26911 |
| 200 | AirLoopHVAC | SPLIT GS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.26911 |
| 201 | AirLoopHVAC | SPLIT GS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.26911 |
| 202 | AirLoopHVAC | SPLIT GS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 203 | AirLoopHVAC | SPLIT GS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 204 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.70502 |
| 205 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.70502 |
| 206 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.70502 |
| 207 | AirLoopHVAC | SPLIT MSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.70502 |
| 208 | AirLoopHVAC | SPLIT MSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.70502 |
| 209 | AirLoopHVAC | SPLIT MSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.70502 |
| 210 | AirLoopHVAC | SPLIT MSW | User Heating Air Flow Ratio [] | 1.00000 |
| 211 | AirLoopHVAC | SPLIT MSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 212 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.67153 |
| 213 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.67153 |
| 214 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.67153 |
| 215 | AirLoopHVAC | SPLIT MNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.67153 |
| 216 | AirLoopHVAC | SPLIT MNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.67153 |
| 217 | AirLoopHVAC | SPLIT MNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.67153 |
| 218 | AirLoopHVAC | SPLIT MNW | User Heating Air Flow Ratio [] | 1.00000 |
| 219 | AirLoopHVAC | SPLIT MNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 220 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.64692 |
| 221 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.64692 |
| 222 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.64692 |
| 223 | AirLoopHVAC | SPLIT MSE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.64692 |
| 224 | AirLoopHVAC | SPLIT MSE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.64692 |
| 225 | AirLoopHVAC | SPLIT MSE | Adjusted Main Design Air Flow Rate [m3/s] | 0.64692 |
| 226 | AirLoopHVAC | SPLIT MSE | User Heating Air Flow Ratio [] | 1.00000 |
| 227 | AirLoopHVAC | SPLIT MSE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 228 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.61404 |
| 229 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.61404 |
| 230 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.61404 |
| 231 | AirLoopHVAC | SPLIT MNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.61404 |
| 232 | AirLoopHVAC | SPLIT MNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.61404 |
| 233 | AirLoopHVAC | SPLIT MNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.61404 |
| 234 | AirLoopHVAC | SPLIT MNE | User Heating Air Flow Ratio [] | 1.00000 |
| 235 | AirLoopHVAC | SPLIT MNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 236 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.54638 |
| 237 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.54638 |
| 238 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.54638 |
| 239 | AirLoopHVAC | SPLIT MN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.54638 |
| 240 | AirLoopHVAC | SPLIT MN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.54638 |
| 241 | AirLoopHVAC | SPLIT MN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.54638 |
| 242 | AirLoopHVAC | SPLIT MN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 243 | AirLoopHVAC | SPLIT MN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 244 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.54536 |
| 245 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.54536 |
| 246 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.54536 |
| 247 | AirLoopHVAC | SPLIT MN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.54536 |
| 248 | AirLoopHVAC | SPLIT MN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.54536 |
| 249 | AirLoopHVAC | SPLIT MN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.54536 |
| 250 | AirLoopHVAC | SPLIT MN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 251 | AirLoopHVAC | SPLIT MN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 252 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.58244 |
| 253 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.58244 |
| 254 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.58244 |
| 255 | AirLoopHVAC | SPLIT MS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.58244 |
| 256 | AirLoopHVAC | SPLIT MS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.58244 |
| 257 | AirLoopHVAC | SPLIT MS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.58244 |
| 258 | AirLoopHVAC | SPLIT MS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 259 | AirLoopHVAC | SPLIT MS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 260 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.58150 |
| 261 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.58150 |
| 262 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.58150 |
| 263 | AirLoopHVAC | SPLIT MS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.58150 |
| 264 | AirLoopHVAC | SPLIT MS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.58150 |
| 265 | AirLoopHVAC | SPLIT MS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.58150 |
| 266 | AirLoopHVAC | SPLIT MS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 267 | AirLoopHVAC | SPLIT MS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 268 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.39212 |
| 269 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.39212 |
| 270 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.39212 |
| 271 | AirLoopHVAC | SPLIT TSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.39212 |
| 272 | AirLoopHVAC | SPLIT TSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.39212 |
| 273 | AirLoopHVAC | SPLIT TSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.39212 |
| 274 | AirLoopHVAC | SPLIT TSW | User Heating Air Flow Ratio [] | 1.00000 |
| 275 | AirLoopHVAC | SPLIT TSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 276 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.37956 |
| 277 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.37956 |
| 278 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.37956 |
| 279 | AirLoopHVAC | SPLIT TNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.37956 |
| 280 | AirLoopHVAC | SPLIT TNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.37956 |
| 281 | AirLoopHVAC | SPLIT TNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.37956 |
| 282 | AirLoopHVAC | SPLIT TNW | User Heating Air Flow Ratio [] | 1.00000 |
| 283 | AirLoopHVAC | SPLIT TNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 284 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.34885 |
| 285 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.34885 |
| 286 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.34885 |
| 287 | AirLoopHVAC | SPLIT TSE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.34885 |
| 288 | AirLoopHVAC | SPLIT TSE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.34885 |
| 289 | AirLoopHVAC | SPLIT TSE | Adjusted Main Design Air Flow Rate [m3/s] | 0.34885 |
| 290 | AirLoopHVAC | SPLIT TSE | User Heating Air Flow Ratio [] | 1.00000 |
| 291 | AirLoopHVAC | SPLIT TSE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 292 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.33633 |
| 293 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.33633 |
| 294 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.33633 |
| 295 | AirLoopHVAC | SPLIT TNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.33633 |
| 296 | AirLoopHVAC | SPLIT TNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.33633 |
| 297 | AirLoopHVAC | SPLIT TNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.33633 |
| 298 | AirLoopHVAC | SPLIT TNE | User Heating Air Flow Ratio [] | 1.00000 |
| 299 | AirLoopHVAC | SPLIT TNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 300 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.31230 |
| 301 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.31230 |
| 302 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.31230 |
| 303 | AirLoopHVAC | SPLIT TN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.31230 |
| 304 | AirLoopHVAC | SPLIT TN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.31230 |
| 305 | AirLoopHVAC | SPLIT TN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.31230 |
| 306 | AirLoopHVAC | SPLIT TN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 307 | AirLoopHVAC | SPLIT TN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 308 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.31090 |
| 309 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.31090 |
| 310 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.31090 |
| 311 | AirLoopHVAC | SPLIT TN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.31090 |
| 312 | AirLoopHVAC | SPLIT TN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.31090 |
| 313 | AirLoopHVAC | SPLIT TN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.31090 |
| 314 | AirLoopHVAC | SPLIT TN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 315 | AirLoopHVAC | SPLIT TN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 316 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.32594 |
| 317 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.32594 |
| 318 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.32594 |
| 319 | AirLoopHVAC | SPLIT TS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.32594 |
| 320 | AirLoopHVAC | SPLIT TS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.32594 |
| 321 | AirLoopHVAC | SPLIT TS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.32594 |
| 322 | AirLoopHVAC | SPLIT TS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 323 | AirLoopHVAC | SPLIT TS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 324 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.32455 |
| 325 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.32455 |
| 326 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.32455 |
| 327 | AirLoopHVAC | SPLIT TS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.32455 |
| 328 | AirLoopHVAC | SPLIT TS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.32455 |
| 329 | AirLoopHVAC | SPLIT TS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.32455 |
| 330 | AirLoopHVAC | SPLIT TS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 331 | AirLoopHVAC | SPLIT TS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 332 | AirLoopHVAC | SPLIT GSW | Design Supply Air Flow Rate [m3/s] | 0.31814 |
| 333 | AirLoopHVAC | SPLIT GNW | Design Supply Air Flow Rate [m3/s] | 0.30248 |
| 334 | AirLoopHVAC | SPLIT OFFICE | Design Supply Air Flow Rate [m3/s] | 0.36810 |
| 335 | AirLoopHVAC | SPLIT GNE | Design Supply Air Flow Rate [m3/s] | 0.28077 |
| 336 | AirLoopHVAC | SPLIT GN1 | Design Supply Air Flow Rate [m3/s] | 0.24596 |
| 337 | AirLoopHVAC | SPLIT GN2 | Design Supply Air Flow Rate [m3/s] | 0.24556 |
| 338 | AirLoopHVAC | SPLIT GS1 | Design Supply Air Flow Rate [m3/s] | 0.26625 |
| 339 | AirLoopHVAC | SPLIT GS2 | Design Supply Air Flow Rate [m3/s] | 0.26911 |
| 340 | AirLoopHVAC | SPLIT MSW | Design Supply Air Flow Rate [m3/s] | 0.70502 |
| 341 | AirLoopHVAC | SPLIT MNW | Design Supply Air Flow Rate [m3/s] | 0.67153 |
| 342 | AirLoopHVAC | SPLIT MSE | Design Supply Air Flow Rate [m3/s] | 0.64692 |
| 343 | AirLoopHVAC | SPLIT MNE | Design Supply Air Flow Rate [m3/s] | 0.61404 |
| 344 | AirLoopHVAC | SPLIT MN1 | Design Supply Air Flow Rate [m3/s] | 0.54638 |
| 345 | AirLoopHVAC | SPLIT MN2 | Design Supply Air Flow Rate [m3/s] | 0.54536 |
| 346 | AirLoopHVAC | SPLIT MS1 | Design Supply Air Flow Rate [m3/s] | 0.58244 |
| 347 | AirLoopHVAC | SPLIT MS2 | Design Supply Air Flow Rate [m3/s] | 0.58150 |
| 348 | AirLoopHVAC | SPLIT TSW | Design Supply Air Flow Rate [m3/s] | 0.39212 |
| 349 | AirLoopHVAC | SPLIT TNW | Design Supply Air Flow Rate [m3/s] | 0.37956 |
| 350 | AirLoopHVAC | SPLIT TSE | Design Supply Air Flow Rate [m3/s] | 0.34885 |
| 351 | AirLoopHVAC | SPLIT TNE | Design Supply Air Flow Rate [m3/s] | 0.33633 |
| 352 | AirLoopHVAC | SPLIT TN1 | Design Supply Air Flow Rate [m3/s] | 0.31230 |
| 353 | AirLoopHVAC | SPLIT TN2 | Design Supply Air Flow Rate [m3/s] | 0.31090 |
| 354 | AirLoopHVAC | SPLIT TS1 | Design Supply Air Flow Rate [m3/s] | 0.32594 |
| 355 | AirLoopHVAC | SPLIT TS2 | Design Supply Air Flow Rate [m3/s] | 0.32455 |
| 356 | Controller:OutdoorAir | SPLIT GSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.31814 |
| 357 | Controller:OutdoorAir | SPLIT GSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 358 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.31814 |
| 359 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.31814 |
| 360 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.31814 |
| 361 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.31814 |
| 362 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5811.37702 |
| 363 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3893.62260 |
| 364 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 365 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5811.37702 |
| 366 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 367 | Fan:OnOff | SPLIT GSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.31814 |
| 368 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31814 |
| 369 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5811.37702 |
| 370 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80017 |
| 371 | Coil:Heating:DX:SingleSpeed | SPLIT GSW HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31814 |
| 372 | Coil:Heating:DX:SingleSpeed | SPLIT GSW HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5811.37702 |
| 373 | Coil:Heating:Electric | SPLIT GSW_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5811.37702 |
| 374 | Controller:OutdoorAir | SPLIT GNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.30248 |
| 375 | Controller:OutdoorAir | SPLIT GNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 376 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.30248 |
| 377 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.30248 |
| 378 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.30248 |
| 379 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.30248 |
| 380 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5546.73360 |
| 381 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3716.31151 |
| 382 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 383 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5546.73360 |
| 384 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 385 | Fan:OnOff | SPLIT GNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.30248 |
| 386 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.30248 |
| 387 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5546.73360 |
| 388 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80089 |
| 389 | Coil:Heating:DX:SingleSpeed | SPLIT GNW HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.30248 |
| 390 | Coil:Heating:DX:SingleSpeed | SPLIT GNW HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5546.73360 |
| 391 | Coil:Heating:Electric | SPLIT GNW_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5546.73360 |
| 392 | Controller:OutdoorAir | SPLIT OFFICE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.36810 |
| 393 | Controller:OutdoorAir | SPLIT OFFICE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 3.81060E-002 |
| 394 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.36810 |
| 395 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.36810 |
| 396 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.36810 |
| 397 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.36810 |
| 398 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6706.82718 |
| 399 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 4493.57421 |
| 400 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 401 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 6706.82718 |
| 402 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 403 | Fan:OnOff | SPLIT OFFICE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.36810 |
| 404 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.36810 |
| 405 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6706.82718 |
| 406 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80003 |
| 407 | Coil:Heating:DX:SingleSpeed | SPLIT OFFICE HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.36810 |
| 408 | Coil:Heating:DX:SingleSpeed | SPLIT OFFICE HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 6706.82718 |
| 409 | Coil:Heating:Electric | SPLIT OFFICE_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 6706.82718 |
| 410 | Controller:OutdoorAir | SPLIT GNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.28077 |
| 411 | Controller:OutdoorAir | SPLIT GNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 412 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.28077 |
| 413 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.28077 |
| 414 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.28077 |
| 415 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.28077 |
| 416 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5222.69515 |
| 417 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3499.20575 |
| 418 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 419 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5222.69515 |
| 420 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 421 | Fan:OnOff | SPLIT GNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.28077 |
| 422 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.28077 |
| 423 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5222.69515 |
| 424 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80018 |
| 425 | Coil:Heating:DX:SingleSpeed | SPLIT GNE HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.28077 |
| 426 | Coil:Heating:DX:SingleSpeed | SPLIT GNE HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5222.69515 |
| 427 | Coil:Heating:Electric | SPLIT GNE_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5222.69515 |
| 428 | Controller:OutdoorAir | SPLIT GN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.24596 |
| 429 | Controller:OutdoorAir | SPLIT GN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 430 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.24596 |
| 431 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.24596 |
| 432 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.24596 |
| 433 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.24596 |
| 434 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 4668.56308 |
| 435 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3127.93726 |
| 436 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 437 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 4668.56308 |
| 438 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 439 | Fan:OnOff | SPLIT GN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.24596 |
| 440 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.24596 |
| 441 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 4668.56308 |
| 442 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.79764 |
| 443 | Coil:Heating:DX:SingleSpeed | SPLIT GN1 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.24596 |
| 444 | Coil:Heating:DX:SingleSpeed | SPLIT GN1 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 4668.56308 |
| 445 | Coil:Heating:Electric | SPLIT GN1_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 4668.56308 |
| 446 | Controller:OutdoorAir | SPLIT GN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.24556 |
| 447 | Controller:OutdoorAir | SPLIT GN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 448 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.24556 |
| 449 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.24556 |
| 450 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.24556 |
| 451 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.24556 |
| 452 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 4662.40968 |
| 453 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3123.81448 |
| 454 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 455 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 4662.40968 |
| 456 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 457 | Fan:OnOff | SPLIT GN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.24556 |
| 458 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.24556 |
| 459 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 4662.40968 |
| 460 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.79754 |
| 461 | Coil:Heating:DX:SingleSpeed | SPLIT GN2 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.24556 |
| 462 | Coil:Heating:DX:SingleSpeed | SPLIT GN2 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 4662.40968 |
| 463 | Coil:Heating:Electric | SPLIT GN2_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 4662.40968 |
| 464 | Controller:OutdoorAir | SPLIT GS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.26625 |
| 465 | Controller:OutdoorAir | SPLIT GS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 466 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.26625 |
| 467 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.26625 |
| 468 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.26625 |
| 469 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.26625 |
| 470 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5025.48549 |
| 471 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3367.07528 |
| 472 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 473 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5025.48549 |
| 474 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 475 | Fan:OnOff | SPLIT GS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.26625 |
| 476 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.26625 |
| 477 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5025.48549 |
| 478 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80043 |
| 479 | Coil:Heating:DX:SingleSpeed | SPLIT GS1 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.26625 |
| 480 | Coil:Heating:DX:SingleSpeed | SPLIT GS1 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5025.48549 |
| 481 | Coil:Heating:Electric | SPLIT GS1_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5025.48549 |
| 482 | Controller:OutdoorAir | SPLIT GS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.26911 |
| 483 | Controller:OutdoorAir | SPLIT GS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 484 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.26911 |
| 485 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.26911 |
| 486 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.26911 |
| 487 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.26911 |
| 488 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5068.79661 |
| 489 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3396.09373 |
| 490 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 491 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5068.79661 |
| 492 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 493 | Fan:OnOff | SPLIT GS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.26911 |
| 494 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.26911 |
| 495 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5068.79661 |
| 496 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80011 |
| 497 | Coil:Heating:DX:SingleSpeed | SPLIT GS2 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.26911 |
| 498 | Coil:Heating:DX:SingleSpeed | SPLIT GS2 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5068.79661 |
| 499 | Coil:Heating:Electric | SPLIT GS2_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5068.79661 |
| 500 | Controller:OutdoorAir | SPLIT MSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.70502 |
| 501 | Controller:OutdoorAir | SPLIT MSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 502 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.70502 |
| 503 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.70502 |
| 504 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.70502 |
| 505 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.70502 |
| 506 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 12723.09920 |
| 507 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8524.47647 |
| 508 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 509 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 12723.09920 |
| 510 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 511 | Fan:OnOff | SPLIT MSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.70502 |
| 512 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.70502 |
| 513 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 12723.09920 |
| 514 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80024 |
| 515 | Coil:Heating:DX:SingleSpeed | SPLIT MSW HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.70502 |
| 516 | Coil:Heating:DX:SingleSpeed | SPLIT MSW HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 12723.09920 |
| 517 | Coil:Heating:Electric | SPLIT MSW_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 12723.09920 |
| 518 | Controller:OutdoorAir | SPLIT MNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.67153 |
| 519 | Controller:OutdoorAir | SPLIT MNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 520 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.67153 |
| 521 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.67153 |
| 522 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.67153 |
| 523 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.67153 |
| 524 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 12174.35388 |
| 525 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8156.81710 |
| 526 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 527 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 12174.35388 |
| 528 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 529 | Fan:OnOff | SPLIT MNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.67153 |
| 530 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.67153 |
| 531 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 12174.35388 |
| 532 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80070 |
| 533 | Coil:Heating:DX:SingleSpeed | SPLIT MNW HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.67153 |
| 534 | Coil:Heating:DX:SingleSpeed | SPLIT MNW HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 12174.35388 |
| 535 | Coil:Heating:Electric | SPLIT MNW_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 12174.35388 |
| 536 | Controller:OutdoorAir | SPLIT MSE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.64692 |
| 537 | Controller:OutdoorAir | SPLIT MSE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 538 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.64692 |
| 539 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.64692 |
| 540 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.64692 |
| 541 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.64692 |
| 542 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 11866.12807 |
| 543 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7950.30581 |
| 544 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 545 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 11866.12807 |
| 546 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 547 | Fan:OnOff | SPLIT MSE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.64692 |
| 548 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.64692 |
| 549 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 11866.12807 |
| 550 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80080 |
| 551 | Coil:Heating:DX:SingleSpeed | SPLIT MSE HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.64692 |
| 552 | Coil:Heating:DX:SingleSpeed | SPLIT MSE HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 11866.12807 |
| 553 | Coil:Heating:Electric | SPLIT MSE_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 11866.12807 |
| 554 | Controller:OutdoorAir | SPLIT MNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.61404 |
| 555 | Controller:OutdoorAir | SPLIT MNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 556 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.61404 |
| 557 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.61404 |
| 558 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.61404 |
| 559 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.61404 |
| 560 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 11317.73501 |
| 561 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7582.88246 |
| 562 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 563 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 11317.73501 |
| 564 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 565 | Fan:OnOff | SPLIT MNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.61404 |
| 566 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.61404 |
| 567 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 11317.73501 |
| 568 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80019 |
| 569 | Coil:Heating:DX:SingleSpeed | SPLIT MNE HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.61404 |
| 570 | Coil:Heating:DX:SingleSpeed | SPLIT MNE HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 11317.73501 |
| 571 | Coil:Heating:Electric | SPLIT MNE_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 11317.73501 |
| 572 | Controller:OutdoorAir | SPLIT MN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.54638 |
| 573 | Controller:OutdoorAir | SPLIT MN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 574 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.54638 |
| 575 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.54638 |
| 576 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.54638 |
| 577 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.54638 |
| 578 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 10244.58261 |
| 579 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 6863.87035 |
| 580 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 581 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 10244.58261 |
| 582 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 583 | Fan:OnOff | SPLIT MN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.54638 |
| 584 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.54638 |
| 585 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 10244.58261 |
| 586 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80059 |
| 587 | Coil:Heating:DX:SingleSpeed | SPLIT MN1 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.54638 |
| 588 | Coil:Heating:DX:SingleSpeed | SPLIT MN1 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 10244.58261 |
| 589 | Coil:Heating:Electric | SPLIT MN1_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 10244.58261 |
| 590 | Controller:OutdoorAir | SPLIT MN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.54536 |
| 591 | Controller:OutdoorAir | SPLIT MN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 592 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.54536 |
| 593 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.54536 |
| 594 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.54536 |
| 595 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.54536 |
| 596 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 10228.45218 |
| 597 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 6853.06296 |
| 598 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 599 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 10228.45218 |
| 600 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 601 | Fan:OnOff | SPLIT MN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.54536 |
| 602 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.54536 |
| 603 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 10228.45218 |
| 604 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80049 |
| 605 | Coil:Heating:DX:SingleSpeed | SPLIT MN2 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.54536 |
| 606 | Coil:Heating:DX:SingleSpeed | SPLIT MN2 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 10228.45218 |
| 607 | Coil:Heating:Electric | SPLIT MN2_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 10228.45218 |
| 608 | Controller:OutdoorAir | SPLIT MS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.58244 |
| 609 | Controller:OutdoorAir | SPLIT MS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 610 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.58244 |
| 611 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.58244 |
| 612 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.58244 |
| 613 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.58244 |
| 614 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 10851.73998 |
| 615 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7270.66579 |
| 616 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 617 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 10851.73998 |
| 618 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 619 | Fan:OnOff | SPLIT MS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.58244 |
| 620 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.58244 |
| 621 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 10851.73998 |
| 622 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80065 |
| 623 | Coil:Heating:DX:SingleSpeed | SPLIT MS1 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.58244 |
| 624 | Coil:Heating:DX:SingleSpeed | SPLIT MS1 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 10851.73998 |
| 625 | Coil:Heating:Electric | SPLIT MS1_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 10851.73998 |
| 626 | Controller:OutdoorAir | SPLIT MS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.58150 |
| 627 | Controller:OutdoorAir | SPLIT MS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 628 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.58150 |
| 629 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.58150 |
| 630 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.58150 |
| 631 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.58150 |
| 632 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 10837.45412 |
| 633 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 7261.09426 |
| 634 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 635 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 10837.45412 |
| 636 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 637 | Fan:OnOff | SPLIT MS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.58150 |
| 638 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.58150 |
| 639 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 10837.45412 |
| 640 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80055 |
| 641 | Coil:Heating:DX:SingleSpeed | SPLIT MS2 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.58150 |
| 642 | Coil:Heating:DX:SingleSpeed | SPLIT MS2 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 10837.45412 |
| 643 | Coil:Heating:Electric | SPLIT MS2_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 10837.45412 |
| 644 | Controller:OutdoorAir | SPLIT TSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.39212 |
| 645 | Controller:OutdoorAir | SPLIT TSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 646 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.39212 |
| 647 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.39212 |
| 648 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.39212 |
| 649 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.39212 |
| 650 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6984.28711 |
| 651 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 4679.47236 |
| 652 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 653 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 6984.28711 |
| 654 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 655 | Fan:OnOff | SPLIT TSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.39212 |
| 656 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.39212 |
| 657 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6984.28711 |
| 658 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80068 |
| 659 | Coil:Heating:DX:SingleSpeed | SPLIT TSW HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.39212 |
| 660 | Coil:Heating:DX:SingleSpeed | SPLIT TSW HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 6984.28711 |
| 661 | Coil:Heating:Electric | SPLIT TSW_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 6984.28711 |
| 662 | Controller:OutdoorAir | SPLIT TNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.37956 |
| 663 | Controller:OutdoorAir | SPLIT TNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 664 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.37956 |
| 665 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.37956 |
| 666 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.37956 |
| 667 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.37956 |
| 668 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6776.99865 |
| 669 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 4540.58909 |
| 670 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 671 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 6776.99865 |
| 672 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 673 | Fan:OnOff | SPLIT TNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.37956 |
| 674 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.37956 |
| 675 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6776.99865 |
| 676 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80086 |
| 677 | Coil:Heating:DX:SingleSpeed | SPLIT TNW HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.37956 |
| 678 | Coil:Heating:DX:SingleSpeed | SPLIT TNW HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 6776.99865 |
| 679 | Coil:Heating:Electric | SPLIT TNW_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 6776.99865 |
| 680 | Controller:OutdoorAir | SPLIT TSE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.34885 |
| 681 | Controller:OutdoorAir | SPLIT TSE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 682 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.34885 |
| 683 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.34885 |
| 684 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.34885 |
| 685 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.34885 |
| 686 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6327.96072 |
| 687 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 4239.73368 |
| 688 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 689 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 6327.96072 |
| 690 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 691 | Fan:OnOff | SPLIT TSE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.34885 |
| 692 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.34885 |
| 693 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6327.96072 |
| 694 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80051 |
| 695 | Coil:Heating:DX:SingleSpeed | SPLIT TSE HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.34885 |
| 696 | Coil:Heating:DX:SingleSpeed | SPLIT TSE HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 6327.96072 |
| 697 | Coil:Heating:Electric | SPLIT TSE_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 6327.96072 |
| 698 | Controller:OutdoorAir | SPLIT TNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.33633 |
| 699 | Controller:OutdoorAir | SPLIT TNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 700 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.33633 |
| 701 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.33633 |
| 702 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.33633 |
| 703 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.33633 |
| 704 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6119.01453 |
| 705 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 4099.73974 |
| 706 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 707 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 6119.01453 |
| 708 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 709 | Fan:OnOff | SPLIT TNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.33633 |
| 710 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.33633 |
| 711 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6119.01453 |
| 712 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80052 |
| 713 | Coil:Heating:DX:SingleSpeed | SPLIT TNE HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.33633 |
| 714 | Coil:Heating:DX:SingleSpeed | SPLIT TNE HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 6119.01453 |
| 715 | Coil:Heating:Electric | SPLIT TNE_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 6119.01453 |
| 716 | Controller:OutdoorAir | SPLIT TN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.31230 |
| 717 | Controller:OutdoorAir | SPLIT TN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 718 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.31230 |
| 719 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.31230 |
| 720 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.31230 |
| 721 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.31230 |
| 722 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5702.99743 |
| 723 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3821.00828 |
| 724 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 725 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5702.99743 |
| 726 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 727 | Fan:OnOff | SPLIT TN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.31230 |
| 728 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31230 |
| 729 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5702.99743 |
| 730 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80027 |
| 731 | Coil:Heating:DX:SingleSpeed | SPLIT TN1 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31230 |
| 732 | Coil:Heating:DX:SingleSpeed | SPLIT TN1 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5702.99743 |
| 733 | Coil:Heating:Electric | SPLIT TN1_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5702.99743 |
| 734 | Controller:OutdoorAir | SPLIT TN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.31090 |
| 735 | Controller:OutdoorAir | SPLIT TN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 736 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.31090 |
| 737 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.31090 |
| 738 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.31090 |
| 739 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.31090 |
| 740 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5681.79418 |
| 741 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3806.80210 |
| 742 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 743 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5681.79418 |
| 744 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 745 | Fan:OnOff | SPLIT TN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.31090 |
| 746 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31090 |
| 747 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5681.79418 |
| 748 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80002 |
| 749 | Coil:Heating:DX:SingleSpeed | SPLIT TN2 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.31090 |
| 750 | Coil:Heating:DX:SingleSpeed | SPLIT TN2 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5681.79418 |
| 751 | Coil:Heating:Electric | SPLIT TN2_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5681.79418 |
| 752 | Controller:OutdoorAir | SPLIT TS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.32594 |
| 753 | Controller:OutdoorAir | SPLIT TS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 754 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.32594 |
| 755 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.32594 |
| 756 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.32594 |
| 757 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.32594 |
| 758 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5932.12561 |
| 759 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3974.52416 |
| 760 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 761 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5932.12561 |
| 762 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 763 | Fan:OnOff | SPLIT TS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.32594 |
| 764 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.32594 |
| 765 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5932.12561 |
| 766 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80040 |
| 767 | Coil:Heating:DX:SingleSpeed | SPLIT TS1 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.32594 |
| 768 | Coil:Heating:DX:SingleSpeed | SPLIT TS1 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5932.12561 |
| 769 | Coil:Heating:Electric | SPLIT TS1_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5932.12561 |
| 770 | Controller:OutdoorAir | SPLIT TS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.32455 |
| 771 | Controller:OutdoorAir | SPLIT TS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 772 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.32455 |
| 773 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.32455 |
| 774 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.32455 |
| 775 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.32455 |
| 776 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5910.99589 |
| 777 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3960.36724 |
| 778 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 779 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5910.99589 |
| 780 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 781 | Fan:OnOff | SPLIT TS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.32455 |
| 782 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.32455 |
| 783 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5910.99589 |
| 784 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80015 |
| 785 | Coil:Heating:DX:SingleSpeed | SPLIT TS2 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.32455 |
| 786 | Coil:Heating:DX:SingleSpeed | SPLIT TS2 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5910.99589 |
| 787 | Coil:Heating:Electric | SPLIT TS2_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5910.99589 |
| 788 | PlantLoop | SWHSYS1 | Maximum Loop Flow Rate [m3/s] | 1.13460E-004 |
| 789 | PlantLoop | SWHSYS1 | Plant Loop Volume [m3] | 1.36152E-002 |
| 790 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Flow Rate [m3/s] | 1.13460E-004 |
| 791 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Power Consumption [W] | 14.49330 |
| 792 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | Use Side Design Flow Rate [m3/s] | 1.13460E-004 |
| Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER User {Btu/W-h} | SEER Standard {Btu/W-h} | IEER {Btu/W-h} | |
| 1 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW HP COOLING COIL | 5561.7 | 3.13 | 10.67 | 11.10 | 10.50 | 10.49 |
| 2 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW HP COOLING COIL | 5309.3 | 3.13 | 10.68 | 11.11 | 10.51 | 10.50 |
| 3 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE HP COOLING COIL | 6418.0 | 3.13 | 10.66 | 11.09 | 10.49 | 10.49 |
| 4 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE HP COOLING COIL | 5002.3 | 3.14 | 10.70 | 11.14 | 10.53 | 10.54 |
| 5 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 HP COOLING COIL | 4475.4 | 3.15 | 10.74 | 11.18 | 10.57 | 10.60 |
| 6 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 HP COOLING COIL | 4469.6 | 3.15 | 10.74 | 11.18 | 10.57 | 10.60 |
| 7 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 HP COOLING COIL | 4816.4 | 3.15 | 10.73 | 11.17 | 10.56 | 10.59 |
| 8 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 HP COOLING COIL | 4857.5 | 3.14 | 10.73 | 11.16 | 10.56 | 10.58 |
| 9 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW HP COOLING COIL | 12169.9 | 3.12 | 10.64 | 11.07 | 10.47 | 10.46 |
| 10 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW HP COOLING COIL | 11647.4 | 3.12 | 10.65 | 11.08 | 10.48 | 10.47 |
| 11 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE HP COOLING COIL | 11358.4 | 3.13 | 10.68 | 11.11 | 10.51 | 10.50 |
| 12 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE HP COOLING COIL | 10835.8 | 3.13 | 10.69 | 11.12 | 10.52 | 10.52 |
| 13 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 HP COOLING COIL | 9815.6 | 3.14 | 10.72 | 11.15 | 10.55 | 10.57 |
| 14 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 HP COOLING COIL | 9800.3 | 3.14 | 10.72 | 11.15 | 10.55 | 10.57 |
| 15 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 HP COOLING COIL | 10394.5 | 3.14 | 10.71 | 11.14 | 10.54 | 10.55 |
| 16 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 HP COOLING COIL | 10381.0 | 3.14 | 10.71 | 11.14 | 10.54 | 10.55 |
| 17 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW HP COOLING COIL | 6676.7 | 3.11 | 10.62 | 11.04 | 10.45 | 10.42 |
| 18 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW HP COOLING COIL | 6479.2 | 3.11 | 10.62 | 11.05 | 10.45 | 10.43 |
| 19 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE HP COOLING COIL | 6054.2 | 3.12 | 10.65 | 11.08 | 10.48 | 10.47 |
| 20 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE HP COOLING COIL | 5855.1 | 3.12 | 10.66 | 11.09 | 10.49 | 10.48 |
| 21 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 HP COOLING COIL | 5457.9 | 3.13 | 10.67 | 11.10 | 10.50 | 10.49 |
| 22 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 HP COOLING COIL | 5437.8 | 3.13 | 10.67 | 11.10 | 10.50 | 10.49 |
| 23 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 HP COOLING COIL | 5676.4 | 3.12 | 10.66 | 11.09 | 10.49 | 10.48 |
| 24 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 HP COOLING COIL | 5656.3 | 3.12 | 10.66 | 11.09 | 10.49 | 10.48 |
| Component Type | Component Name | High Temperature Heating (net) Rating Capacity {W} | Low Temperature Heating (net) Rating Capacity {W} | HSPF {Btu/W-h} | Region Number | |
| 1 | Coil:Heating:DX:SingleSpeed | SPLIT GSW HEATING COIL | 6064.4 | 3366.2 | 8.13 | 4 |
| 2 | Coil:Heating:DX:SingleSpeed | SPLIT GNW HEATING COIL | 5787.4 | 3212.0 | 8.11 | 4 |
| 3 | Coil:Heating:DX:SingleSpeed | SPLIT OFFICE HEATING COIL | 6999.6 | 3885.7 | 8.10 | 4 |
| 4 | Coil:Heating:DX:SingleSpeed | SPLIT GNE HEATING COIL | 5446.1 | 3021.3 | 8.10 | 4 |
| 5 | Coil:Heating:DX:SingleSpeed | SPLIT GN1 HEATING COIL | 4864.4 | 2696.8 | 8.19 | 4 |
| 6 | Coil:Heating:DX:SingleSpeed | SPLIT GN2 HEATING COIL | 4858.0 | 2693.2 | 8.19 | 4 |
| 7 | Coil:Heating:DX:SingleSpeed | SPLIT GS1 HEATING COIL | 5237.5 | 2904.2 | 8.10 | 4 |
| 8 | Coil:Heating:DX:SingleSpeed | SPLIT GS2 HEATING COIL | 5283.0 | 2929.6 | 8.10 | 4 |
| 9 | Coil:Heating:DX:SingleSpeed | SPLIT MSW HEATING COIL | 13283.7 | 7376.5 | 8.07 | 4 |
| 10 | Coil:Heating:DX:SingleSpeed | SPLIT MNW HEATING COIL | 12708.4 | 7055.9 | 8.15 | 4 |
| 11 | Coil:Heating:DX:SingleSpeed | SPLIT MSE HEATING COIL | 12380.8 | 6871.4 | 8.15 | 4 |
| 12 | Coil:Heating:DX:SingleSpeed | SPLIT MNE HEATING COIL | 11806.3 | 6551.5 | 8.12 | 4 |
| 13 | Coil:Heating:DX:SingleSpeed | SPLIT MN1 HEATING COIL | 10679.5 | 5923.0 | 8.15 | 4 |
| 14 | Coil:Heating:DX:SingleSpeed | SPLIT MN2 HEATING COIL | 10662.6 | 5913.6 | 8.15 | 4 |
| 15 | Coil:Heating:DX:SingleSpeed | SPLIT MS1 HEATING COIL | 11315.3 | 6276.9 | 8.11 | 4 |
| 16 | Coil:Heating:DX:SingleSpeed | SPLIT MS2 HEATING COIL | 11300.3 | 6268.5 | 8.11 | 4 |
| 17 | Coil:Heating:DX:SingleSpeed | SPLIT TSW HEATING COIL | 7296.0 | 4053.2 | 8.10 | 4 |
| 18 | Coil:Heating:DX:SingleSpeed | SPLIT TNW HEATING COIL | 7078.7 | 3932.2 | 8.09 | 4 |
| 19 | Coil:Heating:DX:SingleSpeed | SPLIT TSE HEATING COIL | 6605.4 | 3667.4 | 8.08 | 4 |
| 20 | Coil:Heating:DX:SingleSpeed | SPLIT TNE HEATING COIL | 6386.5 | 3545.5 | 8.16 | 4 |
| 21 | Coil:Heating:DX:SingleSpeed | SPLIT TN1 HEATING COIL | 5951.4 | 3303.5 | 8.12 | 4 |
| 22 | Coil:Heating:DX:SingleSpeed | SPLIT TN2 HEATING COIL | 5929.1 | 3291.1 | 8.12 | 4 |
| 23 | Coil:Heating:DX:SingleSpeed | SPLIT TS1 HEATING COIL | 6191.4 | 3437.1 | 8.14 | 4 |
| 24 | Coil:Heating:DX:SingleSpeed | SPLIT TS2 HEATING COIL | 6169.1 | 3424.7 | 8.14 | 4 |
| Zone Name | # Surfaces | |
| 1 | G SW APARTMENT | 9 |
| 2 | G NW APARTMENT | 9 |
| 3 | OFFICE | 9 |
| 4 | G NE APARTMENT | 9 |
| 5 | G N1 APARTMENT | 8 |
| 6 | G N2 APARTMENT | 8 |
| 7 | G S1 APARTMENT | 8 |
| 8 | G S2 APARTMENT | 8 |
| 9 | M SW APARTMENT | 9 |
| 10 | M NW APARTMENT | 9 |
| 11 | M SE APARTMENT | 9 |
| 12 | M NE APARTMENT | 9 |
| 13 | M N1 APARTMENT | 8 |
| 14 | M N2 APARTMENT | 8 |
| 15 | M S1 APARTMENT | 8 |
| 16 | M S2 APARTMENT | 8 |
| 17 | T SW APARTMENT | 9 |
| 18 | T NW APARTMENT | 9 |
| 19 | T SE APARTMENT | 9 |
| 20 | T NE APARTMENT | 9 |
| 21 | T N1 APARTMENT | 8 |
| 22 | T N2 APARTMENT | 8 |
| 23 | T S1 APARTMENT | 8 |
| 24 | T S2 APARTMENT | 8 |
| 25 | T CORRIDOR | 13 |
| 26 | G CORRIDOR | 13 |
| 27 | M CORRIDOR | 13 |
| Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
| 1 | G SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.712 | 0.644 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 2 | GWINDOW1 S SWA | Window | G SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 3 | G WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.712 | 0.644 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 4 | GWINDOW1 W SWA | Window | G WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 5 | G NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 6 | G EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 7 | G GFLOOR SWA | Floor | CTF - ConductionTransferFunction | GGFLOORSWA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 8 | G CEILIN SWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 9 | G INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 10 | G NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.712 | 0.644 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 11 | GWINDOW1 N NWA | Window | G NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 12 | G WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.712 | 0.644 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 13 | GWINDOW1 W NWA | Window | G WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 14 | G SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 15 | G EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 16 | G GFLOOR NWA | Floor | CTF - ConductionTransferFunction | GGFLOORNWA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 17 | G CEILIN NWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 18 | G INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 19 | G SWALL SEA | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.854 | 0.757 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 20 | GWINDOW1 S SEA | Window | G SWALL SEA | Window5 Detailed Fenestration | NONRESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 21 | G EWALL SEA | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.854 | 0.757 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 22 | GWINDOW1 E SEA | Window | G EWALL SEA | Window5 Detailed Fenestration | NONRESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 23 | G NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 24 | iz-G EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 25 | G GFLOOR SEA | Floor | CTF - ConductionTransferFunction | GGFLOORSEA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 26 | G CEILIN SEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 27 | G INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 28 | G NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.712 | 0.644 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 29 | GWINDOW1 N NEA | Window | G NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 30 | G EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.712 | 0.644 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 31 | GWINDOW1 E NEA | Window | G EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 32 | G SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 33 | iz-G EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 34 | G GFLOOR NEA | Floor | CTF - ConductionTransferFunction | GGFLOORNEA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 35 | G CEILIN NEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 36 | G INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 37 | G NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.712 | 0.644 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 38 | GWINDOW1 N N1A | Window | G NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 39 | G SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 40 | G EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 41 | iz-G EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 42 | G GFLOOR N1A | Floor | CTF - ConductionTransferFunction | GGFLOORN1A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 43 | G CEILIN N1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 44 | G INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 45 | G NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.712 | 0.644 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 46 | GWINDOW1 N N2A | Window | G NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 47 | G SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 48 | G EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 49 | iz-G EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 50 | G GFLOOR N2A | Floor | CTF - ConductionTransferFunction | GGFLOORN2A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 51 | G CEILIN N2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 52 | G INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 53 | G SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.712 | 0.644 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 54 | GWINDOW1 S S1A | Window | G SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 55 | G NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 56 | G EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 57 | iz-G EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 58 | G GFLOOR S1A | Floor | CTF - ConductionTransferFunction | GGFLOORS1A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 59 | G CEILIN S1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 60 | G INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 61 | G SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 0.712 | 0.644 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 62 | GWINDOW1 S S2A | Window | G SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 63 | G NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 64 | G EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 65 | iz-G EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 66 | G GFLOOR S2A | Floor | CTF - ConductionTransferFunction | GGFLOORS2A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 67 | G CEILIN S2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 68 | G INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 69 | M WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.727 | 0.655 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 70 | MWINDOW1 W SWA | Window | M WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 71 | M SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.727 | 0.655 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 72 | MWINDOW1 S SWA | Window | M SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 73 | M NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 74 | M EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 3.05 | 7.62 | 0.00 | iz-M EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 75 | M GFLOOR SWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 76 | M CEILIN SWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 77 | M INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 78 | M NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.727 | 0.655 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 79 | MWINDOW1 N NWA | Window | M NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 80 | M WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.727 | 0.655 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 81 | MWINDOW1 W NWA | Window | M WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 82 | M SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 83 | M EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 84 | M GFLOOR NWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 85 | M CEILIN NWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 86 | M INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 87 | M EWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.727 | 0.655 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 88 | MWINDOW1 E SEA | Window | M EWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 89 | M SWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.727 | 0.655 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 90 | MWINDOW1 S SEA | Window | M SWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 91 | M NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 92 | iz-M EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 93 | M GFLOOR SEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 94 | M CEILIN SEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 95 | M INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 96 | M NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.727 | 0.655 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 97 | MWINDOW1 N NEA | Window | M NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 98 | M EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.727 | 0.655 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 99 | MWINDOW1 E NEA | Window | M EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 100 | M SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 101 | iz-M EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 102 | M GFLOOR NEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 103 | M CEILIN NEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 104 | M INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 105 | M NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.727 | 0.655 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 106 | MWINDOW1 N N1A | Window | M NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 107 | M SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 108 | M EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 109 | iz-M EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 110 | M GFLOOR N1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 111 | M CEILIN N1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 112 | M INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 113 | M NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.727 | 0.655 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 114 | MWINDOW1 N N2A | Window | M NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 115 | M SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 116 | M EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 117 | iz-M EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 118 | M GFLOOR N2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 119 | M CEILIN N2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 120 | M INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 121 | M SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.727 | 0.655 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 122 | MWINDOW1 S S1A | Window | M SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 123 | M NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 124 | M EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 125 | iz-M EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 3.05 | 7.62 | 0.00 | M EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 126 | M GFLOOR S1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 127 | M CEILIN S1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 128 | M INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 129 | M SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 0.727 | 0.655 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 130 | MWINDOW1 S S2A | Window | M SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 131 | M NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 132 | M EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 133 | iz-M EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 134 | M GFLOOR S2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 135 | M CEILIN S2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 136 | M INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 137 | T WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 0.957 | 0.837 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 138 | TWINDOW1 W SWA | Window | T WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 139 | T SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 0.957 | 0.837 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 140 | TWINDOW1 S SWA | Window | T SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 141 | T NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 142 | T EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 143 | T GFLOOR SWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 144 | T ROOF SWA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 145 | T INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 146 | T NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 0.957 | 0.837 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 147 | TWINDOW1 N NWA | Window | T NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 148 | T WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 0.957 | 0.837 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 149 | TWINDOW1 W NWA | Window | T WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 150 | T SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 151 | T EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 152 | T GFLOOR NWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 153 | T ROOF NWA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 154 | T INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 155 | T EWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 0.957 | 0.837 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 156 | TWINDOW1 E SEA | Window | T EWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 157 | T SWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 0.957 | 0.837 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 158 | TWINDOW1 S SEA | Window | T SWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 159 | T NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 160 | iz-T EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 161 | T GFLOOR SEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 162 | T ROOF SEA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 163 | T INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 164 | T NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 0.957 | 0.837 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 165 | TWINDOW1 N NEA | Window | T NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 166 | T EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 0.957 | 0.837 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 167 | TWINDOW1 E NEA | Window | T EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 168 | T SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 169 | iz-T EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 170 | T GFLOOR NEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 171 | T ROOF NEA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 172 | T INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 173 | T NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 0.957 | 0.837 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 174 | TWINDOW1 N N1A | Window | T NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 175 | T SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 176 | T EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 177 | iz-T EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 178 | T GFLOOR N1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 179 | T ROOF N1A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 180 | T INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 181 | T NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 0.957 | 0.837 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 182 | TWINDOW1 N N2A | Window | T NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 183 | T SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 184 | T EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 185 | iz-T EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 186 | T GFLOOR N2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 187 | T ROOF N2A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 188 | T INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 189 | T SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 0.957 | 0.837 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 190 | TWINDOW1 S S1A | Window | T SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 191 | T NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 192 | T EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 193 | iz-T EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 194 | T GFLOOR S1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 195 | T ROOF S1A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 196 | T INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 197 | T SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 0.957 | 0.837 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 198 | TWINDOW1 S S2A | Window | T SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 199 | T NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 200 | T EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 201 | iz-T EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 202 | T GFLOOR S2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 203 | T ROOF S2A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 204 | T INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 205 | T WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.109 | 0.951 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 206 | T EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.109 | 0.951 | 3.99 | 5.11 | 3.99 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 207 | TWINDOW14 | Window | T EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 1.11 | 1.11 | 1.11 | 90.00 | 90.00 | 0.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 208 | iz-T NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 209 | iz-T NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 210 | iz-T NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 211 | iz-T NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 212 | iz-T SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 213 | iz-T SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 214 | iz-T SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 215 | iz-T SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 216 | T FLOOR C | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | T FLOOR C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 217 | T ROOF C | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 218 | G WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.854 | 0.757 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 219 | G EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.854 | 0.757 | 1.79 | 5.11 | 1.79 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 220 | ENTRANCE DOOR | Window | G EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 3.32 | 3.32 | 3.32 | 90.00 | 90.00 | 1.57 | 2.11 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 221 | iz-G NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 222 | iz-G NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 223 | iz-G NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 224 | iz-G NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 225 | iz-G SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 226 | iz-G SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 227 | iz-G SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 228 | iz-G SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 229 | G FLOOR C | Floor | CTF - ConductionTransferFunction | GFLOORC_FFACTOR | 5.502E-002 | 5.429E-002 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 230 | G CEILING C | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | G CEILING C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 231 | M WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.869 | 0.769 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 232 | M EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.869 | 0.769 | 3.99 | 5.11 | 3.99 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 233 | MWINDOW14 | Window | M EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.487_SHGC_0.245 | N/A | 2.769 | No | 1.11 | 1.11 | 1.11 | 90.00 | 90.00 | 0.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 234 | iz-M NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 235 | iz-M NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 236 | iz-M NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 237 | iz-M NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 238 | iz-M SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 239 | iz-M SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 240 | iz-M SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 241 | iz-M SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 242 | M FLOOR C | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | M FLOOR C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 243 | M CEILING C | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | M CEILING C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
| Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
| 1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | Yes | Yes | Yes | Clark and Allen |
| Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
| 1 | NEW YEAR'S DAY | Holiday | InputFile | 01/02 | 1Environment:Special Days |
| Daylight Saving Indicator | Source | Start Date | End Date | |
| 1 | Yes | InputFile | 03/12 | 11/05 |
| Style | Unit Conversion | |
| 1 | Commaandhtml | commaandhtml |
| Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
| 1 | G SW APARTMENT | RunPeriod: RUNPERIOD 1 | 0.1901265824 | 0.3958199701 | Pass | Pass | 3.4295253744 | 15.7792075746 | Pass | Pass |
| 2 | G NW APARTMENT | RunPeriod: RUNPERIOD 1 | 5.4528376700E-002 | 0.2043282436 | Pass | Pass | 1.0024974784 | 5.9022325553 | Pass | Pass |
| 3 | OFFICE | RunPeriod: RUNPERIOD 1 | 2.9067642667E-002 | 3.3704654147E-002 | Pass | Pass | 0.1852409566 | 0.3854961565 | Pass | Pass |
| 4 | G NE APARTMENT | RunPeriod: RUNPERIOD 1 | 5.3869809298E-002 | 0.1973373040 | Pass | Pass | 0.7524058769 | 5.0697645572 | Pass | Pass |
| 5 | G N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 4.8189937608E-002 | 0.1781721243 | Pass | Pass | 0.9001101700 | 5.2653235599 | Pass | Pass |
| 6 | G N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 4.8339671939E-002 | 0.1782440748 | Pass | Pass | 0.8525703089 | 4.9976152556 | Pass | Pass |
| 7 | G S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 0.1841181279 | 0.3723356587 | Pass | Pass | 2.8276747220 | 13.8768085808 | Pass | Pass |
| 8 | G S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 0.2025359371 | 0.3817208654 | Pass | Pass | 4.3563434353 | 28.1602533822 | Pass | Pass |
| 9 | M SW APARTMENT | RunPeriod: RUNPERIOD 1 | 0.1898349988 | 0.4047217665 | Pass | Pass | 2.4766021626 | 9.7576315639 | Pass | Pass |
| 10 | M NW APARTMENT | RunPeriod: RUNPERIOD 1 | 4.9637889976E-002 | 0.1943793112 | Pass | Pass | 1.0063978439 | 6.2802316438 | Pass | Pass |
| 11 | M SE APARTMENT | RunPeriod: RUNPERIOD 1 | 0.1928096859 | 0.3964503779 | Pass | Pass | 2.5840681919 | 10.7741536809 | Pass | Pass |
| 12 | M NE APARTMENT | RunPeriod: RUNPERIOD 1 | 5.1871220848E-002 | 0.1935133954 | Pass | Pass | 0.8602207303 | 5.8225612779 | Pass | Pass |
| 13 | M N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 4.5282076105E-002 | 0.1786154867 | Pass | Pass | 5.2469165566 | 54.0579872671 | Pass | Pass |
| 14 | M N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 4.5465312908E-002 | 0.1792059972 | Pass | Pass | 2.1591733466 | 17.6865625311 | Pass | Pass |
| 15 | M S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 0.1819292215 | 0.3771295803 | Pass | Pass | 2.2161974761 | 9.1883164854 | Pass | Pass |
| 16 | M S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 0.1818077161 | 0.3771510361 | Pass | Pass | 2.2160401417 | 9.2179901763 | Pass | Pass |
| 17 | T SW APARTMENT | RunPeriod: RUNPERIOD 1 | 0.2335880754 | 0.4476544738 | Pass | Pass | 2.2539423257 | 9.1846120521 | Pass | Pass |
| 18 | T NW APARTMENT | RunPeriod: RUNPERIOD 1 | 7.9610226681E-002 | 0.2426828144 | Pass | Pass | 0.9622776424 | 6.0342714250 | Pass | Pass |
| 19 | T SE APARTMENT | RunPeriod: RUNPERIOD 1 | 0.2450066391 | 0.4448092594 | Pass | Pass | 2.5212048851 | 10.3016454216 | Pass | Pass |
| 20 | T NE APARTMENT | RunPeriod: RUNPERIOD 1 | 8.1974963381E-002 | 0.2309299388 | Pass | Pass | 0.7446602059 | 5.4722535937 | Pass | Pass |
| 21 | T N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 6.9657466449E-002 | 0.2186677525 | Pass | Pass | 0.6866923556 | 4.9633677329 | Pass | Pass |
| 22 | T N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 6.9447688617E-002 | 0.2180383072 | Pass | Pass | 0.7644967516 | 5.1254552833 | Pass | Pass |
| 23 | T S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 0.2261494532 | 0.4168326806 | Pass | Pass | 2.2466653069 | 9.1721036148 | Pass | Pass |
| 24 | T S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 0.2279788703 | 0.4177286130 | Pass | Pass | 2.2870486081 | 9.3722529767 | Pass | Pass |
| 25 | T CORRIDOR | RunPeriod: RUNPERIOD 1 | 2.3852935124E-002 | 2.4964528974E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 26 | G CORRIDOR | RunPeriod: RUNPERIOD 1 | 0.1248642448 | 0.3180996572 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 27 | M CORRIDOR | RunPeriod: RUNPERIOD 1 | 8.7980895494E-003 | 8.3933847760E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Heat Emission by Components| Envelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
| Heat Emissions [GJ] | 1550.48 | 19.01 | 0.00 | 0.93 | 1255.91 | 2826.34 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
SizingPeriod:DesignDay| Maximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
| TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 4.60 | 0.00 | 4.60 | Wetbulb [C] | 2.50 | 10.00 |
| TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 33.90 | 7.90 | 25.10 | Wetbulb [C] | 3.10 | 270.00 |
| Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
| Jan | 66.00 | 12 | |||
| Feb | 66.00 | 22 | |||
| Mar | 126.00 | 32 | |||
| Apr | 206.00 | 19 | |||
| May | 144.00 | 46 | |||
| Jun | 99.00 | 30 | |||
| Jul | 192.00 | 52 | |||
| Aug | 240.00 | 34 | |||
| Sep | 310.00 | 44 | |||
| Oct | 34.00 | 10 | |||
| Nov | 63.00 | 12 | |||
| Dec | 35.00 | 24 |
| Value | |
| None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Opaque Exterior| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| G SWALL SWA | RES_EXT_WALL_GRD | 0.30 | 0.644 | 0.712 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G WWALL SWA | RES_EXT_WALL_GRD | 0.30 | 0.644 | 0.712 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| G GFLOOR SWA | GGFLOORSWA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL NWA | RES_EXT_WALL_GRD | 0.30 | 0.644 | 0.712 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G WWALL NWA | RES_EXT_WALL_GRD | 0.30 | 0.644 | 0.712 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| G GFLOOR NWA | GGFLOORNWA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL SEA | NONRES_EXT_WALL_GRD | 0.30 | 0.757 | 0.854 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G EWALL SEA | NONRES_EXT_WALL_GRD | 0.30 | 0.757 | 0.854 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| G GFLOOR SEA | GGFLOORSEA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL NEA | RES_EXT_WALL_GRD | 0.30 | 0.644 | 0.712 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G EWALL NEA | RES_EXT_WALL_GRD | 0.30 | 0.644 | 0.712 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| G GFLOOR NEA | GGFLOORNEA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL N1A | RES_EXT_WALL_GRD | 0.30 | 0.644 | 0.712 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G GFLOOR N1A | GGFLOORN1A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL N2A | RES_EXT_WALL_GRD | 0.30 | 0.644 | 0.712 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G GFLOOR N2A | GGFLOORN2A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL S1A | RES_EXT_WALL_GRD | 0.30 | 0.644 | 0.712 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G GFLOOR S1A | GGFLOORS1A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL S2A | RES_EXT_WALL_GRD | 0.30 | 0.644 | 0.712 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G GFLOOR S2A | GGFLOORS2A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| M WWALL SWA | RES_EXT_WALL_MID | 0.30 | 0.655 | 0.727 | 46.45 | 37.16 | 270.00 | 90.00 | W |
| M SWALL SWA | RES_EXT_WALL_MID | 0.30 | 0.655 | 0.727 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M NWALL NWA | RES_EXT_WALL_MID | 0.30 | 0.655 | 0.727 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M WWALL NWA | RES_EXT_WALL_MID | 0.30 | 0.655 | 0.727 | 46.45 | 37.16 | 270.00 | 90.00 | W |
| M EWALL SEA | RES_EXT_WALL_MID | 0.30 | 0.655 | 0.727 | 46.45 | 37.16 | 90.00 | 90.00 | E |
| M SWALL SEA | RES_EXT_WALL_MID | 0.30 | 0.655 | 0.727 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M NWALL NEA | RES_EXT_WALL_MID | 0.30 | 0.655 | 0.727 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M EWALL NEA | RES_EXT_WALL_MID | 0.30 | 0.655 | 0.727 | 46.45 | 37.16 | 90.00 | 90.00 | E |
| M NWALL N1A | RES_EXT_WALL_MID | 0.30 | 0.655 | 0.727 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M NWALL N2A | RES_EXT_WALL_MID | 0.30 | 0.655 | 0.727 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M SWALL S1A | RES_EXT_WALL_MID | 0.30 | 0.655 | 0.727 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M SWALL S2A | RES_EXT_WALL_MID | 0.30 | 0.655 | 0.727 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| T WWALL SWA | RES_EXT_WALL_TOP | 0.30 | 0.837 | 0.957 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| T SWALL SWA | RES_EXT_WALL_TOP | 0.30 | 0.837 | 0.957 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF SWA | RES_ROOF | 0.55 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL NWA | RES_EXT_WALL_TOP | 0.30 | 0.837 | 0.957 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T WWALL NWA | RES_EXT_WALL_TOP | 0.30 | 0.837 | 0.957 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| T ROOF NWA | RES_ROOF | 0.55 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T EWALL SEA | RES_EXT_WALL_TOP | 0.30 | 0.837 | 0.957 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| T SWALL SEA | RES_EXT_WALL_TOP | 0.30 | 0.837 | 0.957 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF SEA | RES_ROOF | 0.55 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL NEA | RES_EXT_WALL_TOP | 0.30 | 0.837 | 0.957 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T EWALL NEA | RES_EXT_WALL_TOP | 0.30 | 0.837 | 0.957 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| T ROOF NEA | RES_ROOF | 0.55 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL N1A | RES_EXT_WALL_TOP | 0.30 | 0.837 | 0.957 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T ROOF N1A | RES_ROOF | 0.55 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL N2A | RES_EXT_WALL_TOP | 0.30 | 0.837 | 0.957 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T ROOF N2A | RES_ROOF | 0.55 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T SWALL S1A | RES_EXT_WALL_TOP | 0.30 | 0.837 | 0.957 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF S1A | RES_ROOF | 0.55 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T SWALL S2A | RES_EXT_WALL_TOP | 0.30 | 0.837 | 0.957 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF S2A | RES_ROOF | 0.55 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T WWALL C | NONRES_EXT_WALL_TOP | 0.30 | 0.951 | 1.109 | 5.11 | 5.11 | 270.00 | 90.00 | W |
| T EWALL C | NONRES_EXT_WALL_TOP | 0.30 | 0.951 | 1.109 | 5.11 | 3.99 | 90.00 | 90.00 | E |
| T ROOF C | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 77.66 | 77.66 | 180.00 | 0.00 | |
| G WWALL C | NONRES_EXT_WALL_GRD | 0.30 | 0.757 | 0.854 | 5.11 | 5.11 | 270.00 | 90.00 | W |
| G EWALL C | NONRES_EXT_WALL_GRD | 0.30 | 0.757 | 0.854 | 5.11 | 1.79 | 90.00 | 90.00 | E |
| G FLOOR C | GFLOORC_FFACTOR | 1.00 | 0.055 | 0.055 | 77.66 | 77.66 | 90.00 | 180.00 | |
| M WWALL C | NONRES_EXT_WALL_MID | 0.30 | 0.769 | 0.869 | 10.22 | 10.22 | 270.00 | 90.00 | W |
| M EWALL C | NONRES_EXT_WALL_MID | 0.30 | 0.769 | 0.869 | 10.22 | 7.99 | 90.00 | 90.00 | E |
| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| G NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| G CEILIN SWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| G CEILIN NWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN SEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN NEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN N1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN N2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN S1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN S2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| M NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| M GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN SWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| M GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN NWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN SEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN NEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN N1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN N2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN S1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN S2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| T NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| T GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| T GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| iz-T NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T FLOOR C | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 77.66 | 77.66 | 90.00 | 180.00 | |
| iz-G NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G CEILING C | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 77.66 | 77.66 | 180.00 | 0.00 | |
| iz-M NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M FLOOR C | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 155.32 | 155.32 | 90.00 | 180.00 | |
| M CEILING C | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 155.32 | 155.32 | 180.00 | 0.00 | |
| G INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| M INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| T INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N |
| Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| GWINDOW1 S SWA | RESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.769 | 0.246 | 0.270 | No | G SWALL SWA | 180.00 | 90.00 | S | |||||||
| GWINDOW1 W SWA | RESWINDOW_U_0.487_SHGC_0.245 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.769 | 0.246 | 0.270 | No | G WWALL SWA | 270.00 | 90.00 | W | |||||||
| GWINDOW1 N NWA | RESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.769 | 0.246 | 0.270 | No | G NWALL NWA | 0.00 | 90.00 | N | |||||||
| GWINDOW1 W NWA | RESWINDOW_U_0.487_SHGC_0.245 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.769 | 0.246 | 0.270 | No | G WWALL NWA | 270.00 | 90.00 | W | |||||||
| GWINDOW1 S SEA | NONRESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.769 | 0.246 | 0.270 | No | G SWALL SEA | 180.00 | 90.00 | S | |||||||
| GWINDOW1 E SEA | NONRESWINDOW_U_0.487_SHGC_0.245 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.769 | 0.246 | 0.270 | No | G EWALL SEA | 90.00 | 90.00 | E | |||||||
| GWINDOW1 N NEA | RESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.769 | 0.246 | 0.270 | No | G NWALL NEA | 0.00 | 90.00 | N | |||||||
| GWINDOW1 E NEA | RESWINDOW_U_0.487_SHGC_0.245 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.769 | 0.246 | 0.270 | No | G EWALL NEA | 90.00 | 90.00 | E | |||||||
| GWINDOW1 N N1A | RESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.769 | 0.246 | 0.270 | No | G NWALL N1A | 0.00 | 90.00 | N | |||||||
| GWINDOW1 N N2A | RESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.769 | 0.246 | 0.270 | No | G NWALL N2A | 0.00 | 90.00 | N | |||||||
| GWINDOW1 S S1A | RESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.769 | 0.246 | 0.270 | No | G SWALL S1A | 180.00 | 90.00 | S | |||||||
| GWINDOW1 S S2A | RESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.769 | 0.246 | 0.270 | No | G SWALL S2A | 180.00 | 90.00 | S | |||||||
| MWINDOW1 W SWA | RESWINDOW_U_0.487_SHGC_0.245 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.769 | 0.246 | 0.270 | No | M WWALL SWA | 270.00 | 90.00 | W | |||||||
| MWINDOW1 S SWA | RESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.769 | 0.246 | 0.270 | No | M SWALL SWA | 180.00 | 90.00 | S | |||||||
| MWINDOW1 N NWA | RESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.769 | 0.246 | 0.270 | No | M NWALL NWA | 0.00 | 90.00 | N | |||||||
| MWINDOW1 W NWA | RESWINDOW_U_0.487_SHGC_0.245 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.769 | 0.246 | 0.270 | No | M WWALL NWA | 270.00 | 90.00 | W | |||||||
| MWINDOW1 E SEA | RESWINDOW_U_0.487_SHGC_0.245 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.769 | 0.246 | 0.270 | No | M EWALL SEA | 90.00 | 90.00 | E | |||||||
| MWINDOW1 S SEA | RESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.769 | 0.246 | 0.270 | No | M SWALL SEA | 180.00 | 90.00 | S | |||||||
| MWINDOW1 N NEA | RESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.769 | 0.246 | 0.270 | No | M NWALL NEA | 0.00 | 90.00 | N | |||||||
| MWINDOW1 E NEA | RESWINDOW_U_0.487_SHGC_0.245 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.769 | 0.246 | 0.270 | No | M EWALL NEA | 90.00 | 90.00 | E | |||||||
| MWINDOW1 N N1A | RESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.769 | 0.246 | 0.270 | No | M NWALL N1A | 0.00 | 90.00 | N | |||||||
| MWINDOW1 N N2A | RESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.769 | 0.246 | 0.270 | No | M NWALL N2A | 0.00 | 90.00 | N | |||||||
| MWINDOW1 S S1A | RESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.769 | 0.246 | 0.270 | No | M SWALL S1A | 180.00 | 90.00 | S | |||||||
| MWINDOW1 S S2A | RESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.769 | 0.246 | 0.270 | No | M SWALL S2A | 180.00 | 90.00 | S | |||||||
| TWINDOW1 W SWA | RESWINDOW_U_0.487_SHGC_0.245 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.769 | 0.246 | 0.270 | No | T WWALL SWA | 270.00 | 90.00 | W | |||||||
| TWINDOW1 S SWA | RESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.769 | 0.246 | 0.270 | No | T SWALL SWA | 180.00 | 90.00 | S | |||||||
| TWINDOW1 N NWA | RESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.769 | 0.246 | 0.270 | No | T NWALL NWA | 0.00 | 90.00 | N | |||||||
| TWINDOW1 W NWA | RESWINDOW_U_0.487_SHGC_0.245 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.769 | 0.246 | 0.270 | No | T WWALL NWA | 270.00 | 90.00 | W | |||||||
| TWINDOW1 E SEA | RESWINDOW_U_0.487_SHGC_0.245 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.769 | 0.246 | 0.270 | No | T EWALL SEA | 90.00 | 90.00 | E | |||||||
| TWINDOW1 S SEA | RESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.769 | 0.246 | 0.270 | No | T SWALL SEA | 180.00 | 90.00 | S | |||||||
| TWINDOW1 N NEA | RESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.769 | 0.246 | 0.270 | No | T NWALL NEA | 0.00 | 90.00 | N | |||||||
| TWINDOW1 E NEA | RESWINDOW_U_0.487_SHGC_0.245 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.769 | 0.246 | 0.270 | No | T EWALL NEA | 90.00 | 90.00 | E | |||||||
| TWINDOW1 N N1A | RESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.769 | 0.246 | 0.270 | No | T NWALL N1A | 0.00 | 90.00 | N | |||||||
| TWINDOW1 N N2A | RESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.769 | 0.246 | 0.270 | No | T NWALL N2A | 0.00 | 90.00 | N | |||||||
| TWINDOW1 S S1A | RESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.769 | 0.246 | 0.270 | No | T SWALL S1A | 180.00 | 90.00 | S | |||||||
| TWINDOW1 S S2A | RESWINDOW_U_0.487_SHGC_0.245 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.769 | 0.246 | 0.270 | No | T SWALL S2A | 180.00 | 90.00 | S | |||||||
| TWINDOW14 | NONRESWINDOW_U_0.487_SHGC_0.245 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.769 | 0.246 | 0.270 | No | T EWALL C | 90.00 | 90.00 | E | |||||||
| ENTRANCE DOOR | NONRESWINDOW_U_0.487_SHGC_0.245 | 3.32 | 0.00 | 0.00 | 3.32 | 3.32 | 2.769 | 0.246 | 0.270 | No | G EWALL C | 90.00 | 90.00 | E | |||||||
| MWINDOW14 | NONRESWINDOW_U_0.487_SHGC_0.245 | 1.11 | 0.00 | 0.00 | 1.11 | 2.23 | 2.769 | 0.246 | 0.270 | No | M EWALL C | 90.00 | 90.00 | E | |||||||
| Total or Average | 306.92 | 2.769 | 0.246 | 0.270 | |||||||||||||||||
| North Total or Average | 112.97 | 2.769 | 0.246 | 0.270 | |||||||||||||||||
| Non-North Total or Average | 193.95 | 2.769 | 0.246 | 0.270 |
| Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
| None |
| Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
| Total or Average | 0.00 | - | - | - |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Sunlit Fraction| March 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
| GWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| GWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| GWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| GWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| GWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| MWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| MWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| TWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| TWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| TWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| TWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| Name | Type | Shaded Construction | Control | Glare Control | |
| None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Interior Lighting| Zone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
| LIGHTING_HARDWIRED_GSW | G SW APARTMENT | G SW APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_GNW | G NW APARTMENT | G NW APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_OFFICE | OFFICE | OFFICE | GENERAL | 7.4895 | 88.25 | 660.94 | LightsWired | LTG_SCH_OFFICE | 46.69 | 168.00 | 45.77 | 0.0000 | Y | 5.68 |
| LIGHTING_HARDWIRED_GNE | G NE APARTMENT | G NE APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_GN1 | G N1 APARTMENT | G N1 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_GN2 | G N2 APARTMENT | G N2 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_GS1 | G S1 APARTMENT | G S1 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_GS2 | G S2 APARTMENT | G S2 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_MSW | M SW APARTMENT | M SW APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_MNW | M NW APARTMENT | M NW APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_MSE | M SE APARTMENT | M SE APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_MNE | M NE APARTMENT | M NE APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_MN1 | M N1 APARTMENT | M N1 APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_MN2 | M N2 APARTMENT | M N2 APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_MS1 | M S1 APARTMENT | M S1 APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_MS2 | M S2 APARTMENT | M S2 APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_TSW | T SW APARTMENT | T SW APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_TNW | T NW APARTMENT | T NW APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_TSE | T SE APARTMENT | T SE APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_TNE | T NE APARTMENT | T NE APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_TN1 | T N1 APARTMENT | T N1 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_TN2 | T N2 APARTMENT | T N2 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_TS1 | T S1 APARTMENT | T S1 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_TS2 | T S2 APARTMENT | T S2 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_GC | G CORRIDOR | G CORRIDOR | GENERAL | 5.2871 | 77.66 | 410.59 | LightsWired | LTG_SCH_CORRIDOR | 126.00 | 168.00 | 126.00 | 0.0000 | N | 9.71 |
| LIGHTING_HARDWIRED_MC | M CORRIDOR | M CORRIDOR | GENERAL | 5.2871 | 155.32 | 821.19 | LightsWired | LTG_SCH_CORRIDOR | 126.00 | 168.00 | 126.00 | 0.0000 | N | 19.42 |
| LIGHTING_HARDWIRED_TC | T CORRIDOR | T CORRIDOR | GENERAL | 5.2871 | 77.66 | 410.59 | LightsWired | LTG_SCH_CORRIDOR | 126.00 | 168.00 | 126.00 | 0.0000 | N | 9.71 |
| LIGHTING_PLUGIN_GSW | G SW APARTMENT | G SW APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_GNW | G NW APARTMENT | G NW APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_GNE | G NE APARTMENT | G NE APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_GN1 | G N1 APARTMENT | G N1 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_GN2 | G N2 APARTMENT | G N2 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_GS1 | G S1 APARTMENT | G S1 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_GS2 | G S2 APARTMENT | G S2 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_MSW | M SW APARTMENT | M SW APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_MNW | M NW APARTMENT | M NW APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_MSE | M SE APARTMENT | M SE APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_MNE | M NE APARTMENT | M NE APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_MN1 | M N1 APARTMENT | M N1 APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_MN2 | M N2 APARTMENT | M N2 APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_MS1 | M S1 APARTMENT | M S1 APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_MS2 | M S2 APARTMENT | M S2 APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_TSW | T SW APARTMENT | T SW APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_TNW | T NW APARTMENT | T NW APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_TSE | T SE APARTMENT | T SE APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_TNE | T NE APARTMENT | T NE APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_TN1 | T N1 APARTMENT | T N1 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_TN2 | T N2 APARTMENT | T N2 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_TS1 | T S1 APARTMENT | T S1 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_TS2 | T S2 APARTMENT | T S2 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| Interior Lighting Total | 2.9507 | 5870.34 | 17321.34 | 55.94 |
| Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
| None |
| Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
| FACADE LIGHTING | 2101.03 | AstronomicalClock | - | 83.73 | 83.73 | 33.02 | |
| Exterior Lighting Total | 2101.03 | 33.02 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Central Plant| Type | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
| None |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
| SPLIT GSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5811.38 | 4650.08 | 1161.29 | 0.80 | 3.82 | |||
| SPLIT GNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5546.73 | 4442.31 | 1104.42 | 0.80 | 3.82 | |||
| SPLIT OFFICE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6706.83 | 5365.64 | 1341.19 | 0.80 | 3.82 | |||
| SPLIT GNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5222.70 | 4179.08 | 1043.61 | 0.80 | 3.82 | |||
| SPLIT GN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4668.56 | 3723.81 | 944.75 | 0.80 | 3.82 | |||
| SPLIT GN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4662.41 | 3718.46 | 943.95 | 0.80 | 3.82 | |||
| SPLIT GS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5025.49 | 4022.57 | 1002.91 | 0.80 | 3.82 | |||
| SPLIT GS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5068.80 | 4055.61 | 1013.19 | 0.80 | 3.82 | |||
| SPLIT MSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 12723.10 | 10181.55 | 2541.55 | 0.80 | 3.82 | |||
| SPLIT MNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 12174.35 | 9748.00 | 2426.36 | 0.80 | 3.82 | |||
| SPLIT MSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 11866.13 | 9502.37 | 2363.75 | 0.80 | 3.82 | |||
| SPLIT MNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 11317.74 | 9056.39 | 2261.34 | 0.80 | 3.82 | |||
| SPLIT MN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10244.58 | 8201.72 | 2042.86 | 0.80 | 3.82 | |||
| SPLIT MN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10228.45 | 8187.82 | 2040.63 | 0.80 | 3.82 | |||
| SPLIT MS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10851.74 | 8688.45 | 2163.29 | 0.80 | 3.82 | |||
| SPLIT MS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10837.45 | 8675.94 | 2161.51 | 0.80 | 3.82 | |||
| SPLIT TSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6984.29 | 5592.20 | 1392.09 | 0.80 | 3.82 | |||
| SPLIT TNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6777.00 | 5427.41 | 1349.58 | 0.80 | 3.82 | |||
| SPLIT TSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6327.96 | 5065.61 | 1262.36 | 0.80 | 3.82 | |||
| SPLIT TNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6119.01 | 4898.39 | 1220.63 | 0.80 | 3.82 | |||
| SPLIT TN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5703.00 | 4563.95 | 1139.05 | 0.80 | 3.82 | |||
| SPLIT TN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5681.79 | 4545.56 | 1136.23 | 0.80 | 3.82 | |||
| SPLIT TS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5932.13 | 4748.07 | 1184.06 | 0.80 | 3.82 | |||
| SPLIT TS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5911.00 | 4729.71 | 1181.29 | 0.80 | 3.82 |
| DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
| SPLIT GSW HP COOLING COIL | 5561.7 | 3.13 | 10.67 | 11.10 | 10.50 | 10.49 | |
| SPLIT GNW HP COOLING COIL | 5309.3 | 3.13 | 10.68 | 11.11 | 10.51 | 10.50 | |
| SPLIT OFFICE HP COOLING COIL | 6418.0 | 3.13 | 10.66 | 11.09 | 10.49 | 10.49 | |
| SPLIT GNE HP COOLING COIL | 5002.3 | 3.14 | 10.70 | 11.14 | 10.53 | 10.54 | |
| SPLIT GN1 HP COOLING COIL | 4475.4 | 3.15 | 10.74 | 11.18 | 10.57 | 10.60 | |
| SPLIT GN2 HP COOLING COIL | 4469.6 | 3.15 | 10.74 | 11.18 | 10.57 | 10.60 | |
| SPLIT GS1 HP COOLING COIL | 4816.4 | 3.15 | 10.73 | 11.17 | 10.56 | 10.59 | |
| SPLIT GS2 HP COOLING COIL | 4857.5 | 3.14 | 10.73 | 11.16 | 10.56 | 10.58 | |
| SPLIT MSW HP COOLING COIL | 12169.9 | 3.12 | 10.64 | 11.07 | 10.47 | 10.46 | |
| SPLIT MNW HP COOLING COIL | 11647.4 | 3.12 | 10.65 | 11.08 | 10.48 | 10.47 | |
| SPLIT MSE HP COOLING COIL | 11358.4 | 3.13 | 10.68 | 11.11 | 10.51 | 10.50 | |
| SPLIT MNE HP COOLING COIL | 10835.8 | 3.13 | 10.69 | 11.12 | 10.52 | 10.52 | |
| SPLIT MN1 HP COOLING COIL | 9815.6 | 3.14 | 10.72 | 11.15 | 10.55 | 10.57 | |
| SPLIT MN2 HP COOLING COIL | 9800.3 | 3.14 | 10.72 | 11.15 | 10.55 | 10.57 | |
| SPLIT MS1 HP COOLING COIL | 10394.5 | 3.14 | 10.71 | 11.14 | 10.54 | 10.55 | |
| SPLIT MS2 HP COOLING COIL | 10381.0 | 3.14 | 10.71 | 11.14 | 10.54 | 10.55 | |
| SPLIT TSW HP COOLING COIL | 6676.7 | 3.11 | 10.62 | 11.04 | 10.45 | 10.42 | |
| SPLIT TNW HP COOLING COIL | 6479.2 | 3.11 | 10.62 | 11.05 | 10.45 | 10.43 | |
| SPLIT TSE HP COOLING COIL | 6054.2 | 3.12 | 10.65 | 11.08 | 10.48 | 10.47 | |
| SPLIT TNE HP COOLING COIL | 5855.1 | 3.12 | 10.66 | 11.09 | 10.49 | 10.48 | |
| SPLIT TN1 HP COOLING COIL | 5457.9 | 3.13 | 10.67 | 11.10 | 10.50 | 10.49 | |
| SPLIT TN2 HP COOLING COIL | 5437.8 | 3.13 | 10.67 | 11.10 | 10.50 | 10.49 | |
| SPLIT TS1 HP COOLING COIL | 5676.4 | 3.12 | 10.66 | 11.09 | 10.49 | 10.48 | |
| SPLIT TS2 HP COOLING COIL | 5656.3 | 3.12 | 10.66 | 11.09 | 10.49 | 10.48 |
| DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
| SPLIT GSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT OFFICE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed |
| DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
| SPLIT GSW HEATING COIL | Coil:Heating:DX:SingleSpeed | 6064.4 | 3366.2 | 8.13 | 4 |
| SPLIT GNW HEATING COIL | Coil:Heating:DX:SingleSpeed | 5787.4 | 3212.0 | 8.11 | 4 |
| SPLIT OFFICE HEATING COIL | Coil:Heating:DX:SingleSpeed | 6999.6 | 3885.7 | 8.10 | 4 |
| SPLIT GNE HEATING COIL | Coil:Heating:DX:SingleSpeed | 5446.1 | 3021.3 | 8.10 | 4 |
| SPLIT GN1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 4864.4 | 2696.8 | 8.19 | 4 |
| SPLIT GN2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 4858.0 | 2693.2 | 8.19 | 4 |
| SPLIT GS1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5237.5 | 2904.2 | 8.10 | 4 |
| SPLIT GS2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5283.0 | 2929.6 | 8.10 | 4 |
| SPLIT MSW HEATING COIL | Coil:Heating:DX:SingleSpeed | 13283.7 | 7376.5 | 8.07 | 4 |
| SPLIT MNW HEATING COIL | Coil:Heating:DX:SingleSpeed | 12708.4 | 7055.9 | 8.15 | 4 |
| SPLIT MSE HEATING COIL | Coil:Heating:DX:SingleSpeed | 12380.8 | 6871.4 | 8.15 | 4 |
| SPLIT MNE HEATING COIL | Coil:Heating:DX:SingleSpeed | 11806.3 | 6551.5 | 8.12 | 4 |
| SPLIT MN1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 10679.5 | 5923.0 | 8.15 | 4 |
| SPLIT MN2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 10662.6 | 5913.6 | 8.15 | 4 |
| SPLIT MS1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 11315.3 | 6276.9 | 8.11 | 4 |
| SPLIT MS2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 11300.3 | 6268.5 | 8.11 | 4 |
| SPLIT TSW HEATING COIL | Coil:Heating:DX:SingleSpeed | 7296.0 | 4053.2 | 8.10 | 4 |
| SPLIT TNW HEATING COIL | Coil:Heating:DX:SingleSpeed | 7078.7 | 3932.2 | 8.09 | 4 |
| SPLIT TSE HEATING COIL | Coil:Heating:DX:SingleSpeed | 6605.4 | 3667.4 | 8.08 | 4 |
| SPLIT TNE HEATING COIL | Coil:Heating:DX:SingleSpeed | 6386.5 | 3545.5 | 8.16 | 4 |
| SPLIT TN1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5951.4 | 3303.5 | 8.12 | 4 |
| SPLIT TN2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5929.1 | 3291.1 | 8.12 | 4 |
| SPLIT TS1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 6191.4 | 3437.1 | 8.14 | 4 |
| SPLIT TS2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 6169.1 | 3424.7 | 8.14 | 4 |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
| SPLIT GSW HEATING COIL | Coil:Heating:DX:SingleSpeed | 5811.38 | 3.81 | |
| SPLIT GSW_SUPPHEATCOIL | Coil:Heating:Electric | 5811.38 | 1.00 | |
| SPLIT GNW HEATING COIL | Coil:Heating:DX:SingleSpeed | 5546.73 | 3.81 | |
| SPLIT GNW_SUPPHEATCOIL | Coil:Heating:Electric | 5546.73 | 1.00 | |
| SPLIT OFFICE HEATING COIL | Coil:Heating:DX:SingleSpeed | 6706.83 | 3.81 | |
| SPLIT OFFICE_SUPPHEATCOIL | Coil:Heating:Electric | 6706.83 | 1.00 | |
| SPLIT GNE HEATING COIL | Coil:Heating:DX:SingleSpeed | 5222.70 | 3.81 | |
| SPLIT GNE_SUPPHEATCOIL | Coil:Heating:Electric | 5222.70 | 1.00 | |
| SPLIT GN1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 4668.56 | 3.81 | |
| SPLIT GN1_SUPPHEATCOIL | Coil:Heating:Electric | 4668.56 | 1.00 | |
| SPLIT GN2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 4662.41 | 3.81 | |
| SPLIT GN2_SUPPHEATCOIL | Coil:Heating:Electric | 4662.41 | 1.00 | |
| SPLIT GS1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5025.49 | 3.81 | |
| SPLIT GS1_SUPPHEATCOIL | Coil:Heating:Electric | 5025.49 | 1.00 | |
| SPLIT GS2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5068.80 | 3.81 | |
| SPLIT GS2_SUPPHEATCOIL | Coil:Heating:Electric | 5068.80 | 1.00 | |
| SPLIT MSW HEATING COIL | Coil:Heating:DX:SingleSpeed | 12723.10 | 3.81 | |
| SPLIT MSW_SUPPHEATCOIL | Coil:Heating:Electric | 12723.10 | 1.00 | |
| SPLIT MNW HEATING COIL | Coil:Heating:DX:SingleSpeed | 12174.35 | 3.81 | |
| SPLIT MNW_SUPPHEATCOIL | Coil:Heating:Electric | 12174.35 | 1.00 | |
| SPLIT MSE HEATING COIL | Coil:Heating:DX:SingleSpeed | 11866.13 | 3.81 | |
| SPLIT MSE_SUPPHEATCOIL | Coil:Heating:Electric | 11866.13 | 1.00 | |
| SPLIT MNE HEATING COIL | Coil:Heating:DX:SingleSpeed | 11317.74 | 3.81 | |
| SPLIT MNE_SUPPHEATCOIL | Coil:Heating:Electric | 11317.74 | 1.00 | |
| SPLIT MN1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 10244.58 | 3.81 | |
| SPLIT MN1_SUPPHEATCOIL | Coil:Heating:Electric | 10244.58 | 1.00 | |
| SPLIT MN2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 10228.45 | 3.81 | |
| SPLIT MN2_SUPPHEATCOIL | Coil:Heating:Electric | 10228.45 | 1.00 | |
| SPLIT MS1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 10851.74 | 3.81 | |
| SPLIT MS1_SUPPHEATCOIL | Coil:Heating:Electric | 10851.74 | 1.00 | |
| SPLIT MS2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 10837.45 | 3.81 | |
| SPLIT MS2_SUPPHEATCOIL | Coil:Heating:Electric | 10837.45 | 1.00 | |
| SPLIT TSW HEATING COIL | Coil:Heating:DX:SingleSpeed | 6984.29 | 3.81 | |
| SPLIT TSW_SUPPHEATCOIL | Coil:Heating:Electric | 6984.29 | 1.00 | |
| SPLIT TNW HEATING COIL | Coil:Heating:DX:SingleSpeed | 6777.00 | 3.81 | |
| SPLIT TNW_SUPPHEATCOIL | Coil:Heating:Electric | 6777.00 | 1.00 | |
| SPLIT TSE HEATING COIL | Coil:Heating:DX:SingleSpeed | 6327.96 | 3.81 | |
| SPLIT TSE_SUPPHEATCOIL | Coil:Heating:Electric | 6327.96 | 1.00 | |
| SPLIT TNE HEATING COIL | Coil:Heating:DX:SingleSpeed | 6119.01 | 3.81 | |
| SPLIT TNE_SUPPHEATCOIL | Coil:Heating:Electric | 6119.01 | 1.00 | |
| SPLIT TN1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5703.00 | 3.81 | |
| SPLIT TN1_SUPPHEATCOIL | Coil:Heating:Electric | 5703.00 | 1.00 | |
| SPLIT TN2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5681.79 | 3.81 | |
| SPLIT TN2_SUPPHEATCOIL | Coil:Heating:Electric | 5681.79 | 1.00 | |
| SPLIT TS1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5932.13 | 3.81 | |
| SPLIT TS1_SUPPHEATCOIL | Coil:Heating:Electric | 5932.13 | 1.00 | |
| SPLIT TS2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5911.00 | 3.81 | |
| SPLIT TS2_SUPPHEATCOIL | Coil:Heating:Electric | 5911.00 | 1.00 |
| Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
| G SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| M SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M SE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M SE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| T SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T SE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T SE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.32 | 356.35 | 1120.11 | 1.00 | 1.86 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.30 | 338.81 | 1120.11 | 1.00 | 1.89 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.37 | 412.31 | 1120.11 | 1.00 | 1.76 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 09:20:00 |
| SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.28 | 314.49 | 1120.11 | 1.00 | 1.94 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.25 | 275.50 | 1120.11 | 1.00 | 2.05 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.25 | 275.06 | 1120.11 | 1.00 | 2.05 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.27 | 298.23 | 1120.11 | 1.00 | 1.99 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.27 | 301.43 | 1120.11 | 1.00 | 1.98 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.71 | 789.70 | 1120.11 | 1.00 | 1.47 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.67 | 752.18 | 1120.11 | 1.00 | 1.49 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.65 | 724.62 | 1120.11 | 1.00 | 1.50 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.61 | 687.79 | 1120.11 | 1.00 | 1.52 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.55 | 612.01 | 1120.11 | 1.00 | 1.57 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.55 | 610.87 | 1120.11 | 1.00 | 1.57 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.58 | 652.39 | 1120.11 | 1.00 | 1.54 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.58 | 651.34 | 1120.11 | 1.00 | 1.54 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.39 | 439.21 | 1120.11 | 1.00 | 1.73 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.38 | 425.15 | 1120.11 | 1.00 | 1.75 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.35 | 390.75 | 1120.11 | 1.00 | 1.80 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.34 | 376.73 | 1120.11 | 1.00 | 1.82 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 349.81 | 1120.11 | 1.00 | 1.87 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 348.25 | 1120.11 | 1.00 | 1.87 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.33 | 365.09 | 1120.11 | 1.00 | 1.84 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.32 | 363.53 | 1120.11 | 1.00 | 1.84 | General | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 |
| Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
| SWHSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 29891.00 | 0.000113 | 14.49 | 127739.32 | 0.30 | General |
| Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
| SWHSYS1 WATER HEATER | WaterHeater:Mixed | 0.95 | 53912.00 | 0.80 | 11.45 | 0.46 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Zone Sensible Cooling| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| G SW APARTMENT | 3760.27 | 4512.32 | 51.13 | 0.265 | 0.318 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00823 | 30.82 | 0.01653 | 0.026 | 0.00 |
| G NW APARTMENT | 3579.22 | 4295.07 | 48.67 | 0.252 | 0.302 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00821 | 30.82 | 0.01653 | 0.026 | 0.00 |
| OFFICE | 4177.28 | 5012.73 | 56.80 | 0.307 | 0.368 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 09:20:00 | 23.90 | 23.90 | 0.00807 | 30.00 | 0.01653 | 0.038 | 0.00 |
| G NE APARTMENT | 3328.98 | 3994.77 | 45.27 | 0.234 | 0.281 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00824 | 30.82 | 0.01653 | 0.026 | 0.00 |
| G N1 APARTMENT | 2927.28 | 3512.74 | 39.80 | 0.205 | 0.246 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00825 | 30.82 | 0.01653 | 0.026 | 0.00 |
| G N2 APARTMENT | 2922.72 | 3507.26 | 39.74 | 0.205 | 0.246 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00825 | 30.82 | 0.01653 | 0.026 | 0.00 |
| G S1 APARTMENT | 3162.37 | 3794.85 | 43.00 | 0.222 | 0.266 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00830 | 30.82 | 0.01653 | 0.026 | 0.00 |
| G S2 APARTMENT | 3195.10 | 3834.13 | 43.45 | 0.224 | 0.269 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00829 | 30.82 | 0.01653 | 0.026 | 0.00 |
| M SW APARTMENT | 8311.92 | 9974.31 | 113.02 | 0.588 | 0.705 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00823 | 30.82 | 0.01653 | 0.052 | 0.00 |
| M NW APARTMENT | 7927.77 | 9513.33 | 107.80 | 0.560 | 0.672 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00822 | 30.82 | 0.01653 | 0.052 | 0.00 |
| M SE APARTMENT | 7644.84 | 9173.80 | 103.95 | 0.539 | 0.647 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00827 | 30.82 | 0.01653 | 0.052 | 0.00 |
| M NE APARTMENT | 7263.59 | 8716.31 | 98.77 | 0.512 | 0.614 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00826 | 30.82 | 0.01653 | 0.052 | 0.00 |
| M N1 APARTMENT | 6483.89 | 7780.67 | 88.17 | 0.455 | 0.546 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00827 | 30.82 | 0.01653 | 0.052 | 0.00 |
| M N2 APARTMENT | 6472.14 | 7766.57 | 88.01 | 0.454 | 0.545 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00827 | 30.82 | 0.01653 | 0.052 | 0.00 |
| M S1 APARTMENT | 6898.48 | 8278.18 | 93.80 | 0.485 | 0.582 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00829 | 30.82 | 0.01653 | 0.052 | 0.00 |
| M S2 APARTMENT | 6887.61 | 8265.14 | 93.66 | 0.485 | 0.581 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00829 | 30.82 | 0.01653 | 0.052 | 0.00 |
| T SW APARTMENT | 4614.48 | 5537.38 | 62.75 | 0.327 | 0.392 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00822 | 30.82 | 0.01653 | 0.026 | 0.00 |
| T NW APARTMENT | 4469.40 | 5363.28 | 60.77 | 0.316 | 0.380 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00821 | 30.82 | 0.01653 | 0.026 | 0.00 |
| T SE APARTMENT | 4115.28 | 4938.34 | 55.96 | 0.291 | 0.349 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00825 | 30.82 | 0.01653 | 0.026 | 0.00 |
| T NE APARTMENT | 3971.31 | 4765.57 | 54.00 | 0.280 | 0.336 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00824 | 30.82 | 0.01653 | 0.026 | 0.00 |
| T N1 APARTMENT | 3695.45 | 4434.54 | 50.25 | 0.260 | 0.312 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00820 | 30.82 | 0.01653 | 0.026 | 0.00 |
| T N2 APARTMENT | 3679.47 | 4415.36 | 50.03 | 0.259 | 0.311 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00820 | 30.82 | 0.01653 | 0.026 | 0.00 |
| T S1 APARTMENT | 3852.01 | 4622.41 | 52.38 | 0.272 | 0.326 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00822 | 30.82 | 0.01653 | 0.026 | 0.00 |
| T S2 APARTMENT | 3835.96 | 4603.15 | 52.16 | 0.270 | 0.325 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 24.00 | 24.00 | 0.00822 | 30.82 | 0.01653 | 0.026 | 0.00 |
| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| G SW APARTMENT | 656.14 | 787.37 | 8.92 | 0.028 | 0.034 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 21.10 | 21.10 | 0.00780 | 4.60 | 0.00526 | 0.026 | 0.00 |
| G NW APARTMENT | 536.07 | 643.28 | 7.29 | 0.023 | 0.028 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 21.10 | 21.10 | 0.00831 | 4.60 | 0.00526 | 0.026 | 0.00 |
| OFFICE | 1048.99 | 1258.79 | 14.26 | 0.045 | 0.054 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | 21.10 | 21.10 | 0.00787 | 4.60 | 0.00526 | 0.038 | 0.00 |
| G NE APARTMENT | 537.04 | 644.44 | 7.30 | 0.023 | 0.028 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 21.10 | 21.10 | 0.00831 | 4.60 | 0.00526 | 0.026 | 0.00 |
| G N1 APARTMENT | 241.70 | 290.05 | 3.29 | 0.010 | 0.026 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 21.10 | 21.10 | 0.00881 | 4.60 | 0.00526 | 0.026 | 0.00 |
| G N2 APARTMENT | 241.73 | 290.08 | 3.29 | 0.010 | 0.026 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 21.10 | 21.10 | 0.00880 | 4.60 | 0.00526 | 0.026 | 0.00 |
| G S1 APARTMENT | 360.86 | 433.03 | 4.91 | 0.016 | 0.026 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 21.10 | 21.10 | 0.00776 | 4.60 | 0.00526 | 0.026 | 0.00 |
| G S2 APARTMENT | 372.06 | 446.47 | 5.06 | 0.016 | 0.026 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 21.10 | 21.10 | 0.00777 | 4.60 | 0.00526 | 0.026 | 0.00 |
| M SW APARTMENT | 1393.31 | 1671.98 | 18.95 | 0.060 | 0.072 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00774 | 4.60 | 0.00526 | 0.052 | 0.00 |
| M NW APARTMENT | 1120.13 | 1344.16 | 15.23 | 0.048 | 0.058 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00820 | 4.60 | 0.00526 | 0.052 | 0.00 |
| M SE APARTMENT | 1395.69 | 1674.83 | 18.98 | 0.060 | 0.072 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00774 | 4.60 | 0.00526 | 0.052 | 0.00 |
| M NE APARTMENT | 1122.63 | 1347.15 | 15.27 | 0.048 | 0.058 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00820 | 4.60 | 0.00526 | 0.052 | 0.00 |
| M N1 APARTMENT | 418.61 | 502.34 | 5.69 | 0.018 | 0.052 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00874 | 4.60 | 0.00526 | 0.052 | 0.00 |
| M N2 APARTMENT | 418.68 | 502.41 | 5.69 | 0.018 | 0.052 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00874 | 4.60 | 0.00526 | 0.052 | 0.00 |
| M S1 APARTMENT | 680.65 | 816.78 | 9.26 | 0.029 | 0.052 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00763 | 4.60 | 0.00526 | 0.052 | 0.00 |
| M S2 APARTMENT | 680.71 | 816.85 | 9.26 | 0.029 | 0.052 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00763 | 4.60 | 0.00526 | 0.052 | 0.00 |
| T SW APARTMENT | 1305.26 | 1566.31 | 17.75 | 0.056 | 0.068 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00782 | 4.60 | 0.00526 | 0.026 | 0.00 |
| T NW APARTMENT | 1158.04 | 1389.65 | 15.75 | 0.050 | 0.060 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00805 | 4.60 | 0.00526 | 0.026 | 0.00 |
| T SE APARTMENT | 1306.44 | 1567.72 | 17.76 | 0.056 | 0.068 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00782 | 4.60 | 0.00526 | 0.026 | 0.00 |
| T NE APARTMENT | 1159.31 | 1391.17 | 15.76 | 0.050 | 0.060 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00805 | 4.60 | 0.00526 | 0.026 | 0.00 |
| T N1 APARTMENT | 767.98 | 921.57 | 10.44 | 0.033 | 0.040 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00820 | 4.60 | 0.00526 | 0.026 | 0.00 |
| T N2 APARTMENT | 768.01 | 921.62 | 10.44 | 0.033 | 0.040 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00820 | 4.60 | 0.00526 | 0.026 | 0.00 |
| T S1 APARTMENT | 915.21 | 1098.25 | 12.44 | 0.039 | 0.047 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00784 | 4.60 | 0.00526 | 0.026 | 0.00 |
| T S2 APARTMENT | 915.24 | 1098.29 | 12.45 | 0.039 | 0.047 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00784 | 4.60 | 0.00526 | 0.026 | 0.00 |
| Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
| SPLIT GSW | 0.32 | 0.32 | 0.03 | 0.03 | 0.3181 | 0.3181 | 0.3181 | 1.0000 | 1.0000 |
| SPLIT GNW | 0.30 | 0.30 | 0.03 | 0.03 | 0.3025 | 0.3025 | 0.3025 | 1.0000 | 1.0000 |
| SPLIT OFFICE | 0.37 | 0.37 | 0.05 | 0.05 | 0.3681 | 0.3681 | 0.3681 | 1.0000 | 1.0000 |
| SPLIT GNE | 0.28 | 0.28 | 0.03 | 0.03 | 0.2808 | 0.2808 | 0.2808 | 1.0000 | 1.0000 |
| SPLIT GN1 | 0.25 | 0.25 | 0.03 | 0.03 | 0.2460 | 0.2460 | 0.2460 | 1.0000 | 1.0000 |
| SPLIT GN2 | 0.25 | 0.25 | 0.03 | 0.03 | 0.2456 | 0.2456 | 0.2456 | 1.0000 | 1.0000 |
| SPLIT GS1 | 0.27 | 0.27 | 0.03 | 0.03 | 0.2662 | 0.2662 | 0.2662 | 1.0000 | 1.0000 |
| SPLIT GS2 | 0.27 | 0.27 | 0.03 | 0.03 | 0.2691 | 0.2691 | 0.2691 | 1.0000 | 1.0000 |
| SPLIT MSW | 0.71 | 0.71 | 0.07 | 0.07 | 0.7050 | 0.7050 | 0.7050 | 1.0000 | 1.0000 |
| SPLIT MNW | 0.67 | 0.67 | 0.06 | 0.06 | 0.6715 | 0.6715 | 0.6715 | 1.0000 | 1.0000 |
| SPLIT MSE | 0.65 | 0.65 | 0.07 | 0.07 | 0.6469 | 0.6469 | 0.6469 | 1.0000 | 1.0000 |
| SPLIT MNE | 0.61 | 0.61 | 0.06 | 0.06 | 0.6140 | 0.6140 | 0.6140 | 1.0000 | 1.0000 |
| SPLIT MN1 | 0.55 | 0.55 | 0.05 | 0.05 | 0.5464 | 0.5464 | 0.5464 | 1.0000 | 1.0000 |
| SPLIT MN2 | 0.55 | 0.55 | 0.05 | 0.05 | 0.5454 | 0.5454 | 0.5454 | 1.0000 | 1.0000 |
| SPLIT MS1 | 0.58 | 0.58 | 0.05 | 0.05 | 0.5824 | 0.5824 | 0.5824 | 1.0000 | 1.0000 |
| SPLIT MS2 | 0.58 | 0.58 | 0.05 | 0.05 | 0.5815 | 0.5815 | 0.5815 | 1.0000 | 1.0000 |
| SPLIT TSW | 0.39 | 0.39 | 0.07 | 0.07 | 0.3921 | 0.3921 | 0.3921 | 1.0000 | 1.0000 |
| SPLIT TNW | 0.38 | 0.38 | 0.06 | 0.06 | 0.3796 | 0.3796 | 0.3796 | 1.0000 | 1.0000 |
| SPLIT TSE | 0.35 | 0.35 | 0.07 | 0.07 | 0.3489 | 0.3489 | 0.3489 | 1.0000 | 1.0000 |
| SPLIT TNE | 0.34 | 0.34 | 0.06 | 0.06 | 0.3363 | 0.3363 | 0.3363 | 1.0000 | 1.0000 |
| SPLIT TN1 | 0.31 | 0.31 | 0.04 | 0.04 | 0.3123 | 0.3123 | 0.3123 | 1.0000 | 1.0000 |
| SPLIT TN2 | 0.31 | 0.31 | 0.04 | 0.04 | 0.3109 | 0.3109 | 0.3109 | 1.0000 | 1.0000 |
| SPLIT TS1 | 0.33 | 0.33 | 0.05 | 0.05 | 0.3259 | 0.3259 | 0.3259 | 1.0000 | 1.0000 |
| SPLIT TS2 | 0.32 | 0.32 | 0.05 | 0.05 | 0.3245 | 0.3245 | 0.3245 | 1.0000 | 1.0000 |
| Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
| None |
| Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
| SPLIT GSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GSW | 5811.377 | 4650.085 | 0.318135 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 5678.74 | 4927.33 | 0.318135 | 25.50 | 17.25 | 0.00890412 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 8.1583 | 24.00 | 0.00822666 | 44.2697 | 3760.27 | 0.00 | 5810.39 | 4644.35 |
| SPLIT GSW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT GSW | 5811.377 | 5811.377 | 0.318135 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 5811.38 | 5811.38 | 0.318135 | 19.75 | 13.99 | 0.00759310 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 8.1583 | 21.10 | 0.00780060 | 50.0941 | 656.14 | 0.00 | 5819.01 | 5819.01 |
| SPLIT GSW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT GSW | 5811.377 | 5811.377 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 5811.38 | 5811.38 | 0.318135 | 19.75 | 13.99 | 0.00759310 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 8.1583 | 21.10 | 0.00780060 | 50.0941 | 656.14 | 0.00 | -999.00 | -999.00 |
| SPLIT GNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GNW | 5546.734 | 4442.313 | 0.302480 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 5423.09 | 4694.56 | 0.302480 | 25.53 | 17.27 | 0.00892154 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 8.5806 | 24.00 | 0.00820736 | 44.1667 | 3579.22 | 0.00 | 5545.79 | 4436.43 |
| SPLIT GNW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT GNW | 5546.734 | 5546.734 | 0.302480 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 5546.73 | 5546.73 | 0.302480 | 19.68 | 14.39 | 0.00804679 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 8.5806 | 21.10 | 0.00830862 | 53.3124 | 536.07 | 0.00 | 5554.02 | 5554.02 |
| SPLIT GNW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT GNW | 5546.734 | 5546.734 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 5546.73 | 5546.73 | 0.302480 | 19.68 | 14.39 | 0.00804679 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 8.5806 | 21.10 | 0.00830862 | 53.3124 | 536.07 | 0.00 | -999.00 | -999.00 |
| SPLIT OFFICE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT OFFICE | 6706.827 | 5365.639 | 0.368100 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 11:40:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 09:20:00 | 6592.51 | 5681.62 | 0.368100 | 25.44 | 17.26 | 0.00894681 | 12.80 | 11.59 | 0.00800000 | 30.00 | 0.01652904 | 24.11 | 10.3521 | 23.90 | 0.00806581 | 43.6752 | 4112.11 | 0.00 | 6705.69 | 5359.34 |
| SPLIT OFFICE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT OFFICE | 6706.827 | 6706.827 | 0.368100 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | 6706.83 | 6706.83 | 0.368100 | 19.39 | 13.86 | 0.00760289 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 10.3521 | 21.10 | 0.00787376 | 50.5579 | 1048.99 | 0.00 | 6715.64 | 6715.64 |
| SPLIT OFFICE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT OFFICE | 6706.827 | 6706.827 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | 6706.83 | 6706.83 | 0.368100 | 19.39 | 13.86 | 0.00760289 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 10.3521 | 21.10 | 0.00787376 | 50.5579 | 1048.99 | 0.00 | -999.00 | -999.00 |
| SPLIT GNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GNE | 5222.695 | 4179.084 | 0.280767 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 5116.55 | 4376.39 | 0.280767 | 25.56 | 17.35 | 0.00900685 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 9.2442 | 24.00 | 0.00824051 | 44.3430 | 3328.98 | 0.00 | 5221.81 | 4173.78 |
| SPLIT GNE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT GNE | 5222.695 | 5222.695 | 0.280767 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 5222.70 | 5222.70 | 0.280767 | 19.57 | 14.33 | 0.00802615 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 9.2442 | 21.10 | 0.00830819 | 53.3096 | 537.04 | 0.00 | 5229.56 | 5229.56 |
| SPLIT GNE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT GNE | 5222.695 | 5222.695 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 5222.70 | 5222.70 | 0.280767 | 19.57 | 14.33 | 0.00802615 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 9.2442 | 21.10 | 0.00830819 | 53.3096 | 537.04 | 0.00 | -999.00 | -999.00 |
| SPLIT GN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GN1 | 4668.563 | 3723.814 | 0.245959 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 4586.92 | 3860.70 | 0.245959 | 25.63 | 17.47 | 0.00912494 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 10.5524 | 24.00 | 0.00825128 | 44.4001 | 2927.28 | 0.00 | 4667.77 | 3719.69 |
| SPLIT GN1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT GN1 | 4668.563 | 4668.563 | 0.245959 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:20:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:30:00 | 4668.56 | 4668.56 | 0.245959 | 19.36 | 14.62 | 0.00843069 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 10.5524 | 21.10 | 0.00872559 | 55.9508 | 199.62 | 0.00 | 4674.70 | 4674.70 |
| SPLIT GN1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT GN1 | 4668.563 | 4668.563 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:20:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:30:00 | 4668.56 | 4668.56 | 0.245959 | 19.36 | 14.62 | 0.00843069 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 10.5524 | 21.10 | 0.00872559 | 55.9508 | 199.62 | 0.00 | -999.00 | -999.00 |
| SPLIT GN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GN2 | 4662.410 | 3718.462 | 0.245562 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 4581.07 | 3854.83 | 0.245562 | 25.63 | 17.48 | 0.00912675 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 10.5694 | 24.00 | 0.00825172 | 44.4025 | 2922.72 | 0.00 | 4661.62 | 3714.30 |
| SPLIT GN2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT GN2 | 4662.410 | 4662.410 | 0.245562 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 4662.41 | 4662.41 | 0.245562 | 19.36 | 14.62 | 0.00843001 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 10.5694 | 21.10 | 0.00871857 | 55.9065 | 194.00 | 0.00 | 4668.54 | 4668.54 |
| SPLIT GN2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT GN2 | 4662.410 | 4662.410 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 4662.41 | 4662.41 | 0.245562 | 19.36 | 14.62 | 0.00843001 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 10.5694 | 21.10 | 0.00871857 | 55.9065 | 194.00 | 0.00 | -999.00 | -999.00 |
| SPLIT GS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GS1 | 5025.485 | 4022.572 | 0.266249 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 4933.56 | 4165.70 | 0.266249 | 25.59 | 17.44 | 0.00909951 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 9.7482 | 24.00 | 0.00829687 | 44.6430 | 3162.37 | 0.00 | 5024.63 | 4012.53 |
| SPLIT GS1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT GS1 | 5025.485 | 5025.485 | 0.266249 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 5025.49 | 5025.49 | 0.266249 | 19.49 | 13.82 | 0.00751512 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 9.7482 | 21.10 | 0.00772086 | 49.5882 | 306.49 | 0.00 | 5032.09 | 5032.09 |
| SPLIT GS1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT GS1 | 5025.485 | 5025.485 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 5025.49 | 5025.49 | 0.266249 | 19.49 | 13.82 | 0.00751512 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 9.7482 | 21.10 | 0.00772086 | 49.5882 | 306.49 | 0.00 | -999.00 | -999.00 |
| SPLIT GS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GS2 | 5068.797 | 4055.606 | 0.269108 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 4974.58 | 4207.54 | 0.269108 | 25.59 | 17.43 | 0.00908695 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 9.6447 | 24.00 | 0.00829240 | 44.6193 | 3195.10 | 0.00 | 5067.93 | 4050.63 |
| SPLIT GS2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT GS2 | 5068.797 | 5068.797 | 0.269108 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 17:40:00 | 5068.80 | 5068.80 | 0.269108 | 19.51 | 13.83 | 0.00752571 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 9.6447 | 21.10 | 0.00773168 | 49.6568 | 318.63 | 0.00 | 5075.46 | 5075.46 |
| SPLIT GS2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT GS2 | 5068.797 | 5068.797 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 17:40:00 | 5068.80 | 5068.80 | 0.269108 | 19.51 | 13.83 | 0.00752571 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 9.6447 | 21.10 | 0.00773168 | 49.6568 | 318.63 | 0.00 | -999.00 | -999.00 |
| SPLIT MSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MSW | 12723.099 | 10181.550 | 0.705021 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 12411.70 | 10869.11 | 0.705021 | 25.45 | 17.18 | 0.00883883 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 7.3628 | 24.00 | 0.00822749 | 44.2741 | 16623.84 | 0.00 | 12720.93 | 10167.21 |
| SPLIT MSW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MSW | 12723.099 | 12723.099 | 0.705021 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 12723.10 | 12723.10 | 0.705021 | 19.88 | 14.01 | 0.00755502 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 7.3628 | 21.10 | 0.00773765 | 49.6950 | 2786.63 | 0.00 | 12739.82 | 12739.82 |
| SPLIT MSW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MSW | 12723.099 | 12723.099 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 12723.10 | 12723.10 | 0.705021 | 19.88 | 14.01 | 0.00755502 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 7.3628 | 21.10 | 0.00773765 | 49.6950 | 2786.63 | 0.00 | -999.00 | -999.00 |
| SPLIT MNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MNW | 12174.354 | 9747.996 | 0.671528 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 11883.98 | 10374.35 | 0.671528 | 25.48 | 17.20 | 0.00886135 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 7.7300 | 24.00 | 0.00821886 | 44.2280 | 15855.55 | 0.00 | 12172.28 | 9737.47 |
| SPLIT MNW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MNW | 12174.354 | 12174.354 | 0.671528 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 12174.35 | 12174.35 | 0.671528 | 19.82 | 14.37 | 0.00796943 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 7.7300 | 21.10 | 0.00819666 | 52.6035 | 2240.27 | 0.00 | 12190.35 | 12190.35 |
| SPLIT MNW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MNW | 12174.354 | 12174.354 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 12174.35 | 12174.35 | 0.671528 | 19.82 | 14.37 | 0.00796943 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 7.7300 | 21.10 | 0.00819666 | 52.6035 | 2240.27 | 0.00 | -999.00 | -999.00 |
| SPLIT MSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MSE | 11866.128 | 9502.375 | 0.646921 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 11601.83 | 10020.57 | 0.646921 | 25.49 | 17.27 | 0.00893515 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 8.0240 | 24.00 | 0.00827252 | 44.5136 | 15289.67 | 0.00 | 11864.11 | 9489.73 |
| SPLIT MSE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MSE | 11866.128 | 11866.128 | 0.646921 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 11866.13 | 11866.13 | 0.646921 | 19.78 | 13.95 | 0.00753903 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 8.0240 | 21.10 | 0.00773810 | 49.6979 | 2791.38 | 0.00 | 11881.72 | 11881.72 |
| SPLIT MSE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MSE | 11866.128 | 11866.128 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 11866.13 | 11866.13 | 0.646921 | 19.78 | 13.95 | 0.00753903 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 8.0240 | 21.10 | 0.00773810 | 49.6979 | 2791.38 | 0.00 | -999.00 | -999.00 |
| SPLIT MNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MNE | 11317.735 | 9056.393 | 0.614042 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 11073.24 | 9532.04 | 0.614042 | 25.52 | 17.30 | 0.00895969 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 8.4537 | 24.00 | 0.00826057 | 44.4498 | 14527.18 | 0.00 | 11315.81 | 9043.29 |
| SPLIT MNE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MNE | 11317.735 | 11317.735 | 0.614042 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 11317.74 | 11317.74 | 0.614042 | 19.71 | 14.30 | 0.00794787 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 8.4537 | 21.10 | 0.00819634 | 52.6015 | 2245.25 | 0.00 | 11332.61 | 11332.61 |
| SPLIT MNE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MNE | 11317.735 | 11317.735 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 11317.74 | 11317.74 | 0.614042 | 19.71 | 14.30 | 0.00794787 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 8.4537 | 21.10 | 0.00819634 | 52.6015 | 2245.25 | 0.00 | -999.00 | -999.00 |
| SPLIT MN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MN1 | 10244.583 | 8201.720 | 0.546385 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 10047.65 | 8533.87 | 0.546385 | 25.58 | 17.40 | 0.00905712 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 9.5005 | 24.00 | 0.00827257 | 44.5135 | 12967.78 | 0.00 | 10242.84 | 8192.91 |
| SPLIT MN1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MN1 | 10244.583 | 10244.583 | 0.546385 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:20:00 | 10244.58 | 10244.58 | 0.546385 | 19.53 | 14.67 | 0.00841206 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 9.5005 | 21.10 | 0.00863973 | 55.4081 | 569.59 | 0.00 | 10258.05 | 10258.05 |
| SPLIT MN1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MN1 | 10244.583 | 10244.583 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:20:00 | 10244.58 | 10244.58 | 0.546385 | 19.53 | 14.67 | 0.00841206 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 9.5005 | 21.10 | 0.00863973 | 55.4081 | 569.59 | 0.00 | -999.00 | -999.00 |
| SPLIT MN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MN2 | 10228.452 | 8187.822 | 0.545363 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 10032.25 | 8518.76 | 0.545363 | 25.58 | 17.40 | 0.00905886 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 9.5183 | 24.00 | 0.00827287 | 44.5151 | 12944.29 | 0.00 | 10226.71 | 8178.93 |
| SPLIT MN2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MN2 | 10228.452 | 10228.452 | 0.545363 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 10228.45 | 10228.45 | 0.545363 | 19.53 | 14.66 | 0.00841135 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 9.5183 | 21.10 | 0.00863964 | 55.4075 | 569.71 | 0.00 | 10241.89 | 10241.89 |
| SPLIT MN2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MN2 | 10228.452 | 10228.452 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 10228.45 | 10228.45 | 0.545363 | 19.53 | 14.66 | 0.00841135 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 9.5183 | 21.10 | 0.00863964 | 55.4075 | 569.71 | 0.00 | -999.00 | -999.00 |
| SPLIT MS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MS1 | 10851.740 | 8688.448 | 0.582439 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 10633.46 | 9069.22 | 0.582439 | 25.54 | 17.36 | 0.00902550 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 8.9124 | 24.00 | 0.00829118 | 44.6127 | 13796.96 | 0.00 | 10849.89 | 8677.06 |
| SPLIT MS1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MS1 | 10851.740 | 10851.740 | 0.582439 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 10851.74 | 10851.74 | 0.582439 | 19.63 | 13.78 | 0.00741721 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 8.9124 | 21.10 | 0.00752676 | 48.3566 | 1041.91 | 0.00 | 10866.00 | 10866.00 |
| SPLIT MS1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MS1 | 10851.740 | 10851.740 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 10851.74 | 10851.74 | 0.582439 | 19.63 | 13.78 | 0.00741721 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 8.9124 | 21.10 | 0.00752676 | 48.3566 | 1041.91 | 0.00 | -999.00 | -999.00 |
| SPLIT MS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MS2 | 10837.454 | 8675.940 | 0.581496 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 10619.91 | 9055.39 | 0.581496 | 25.54 | 17.36 | 0.00902732 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 8.9268 | 24.00 | 0.00829187 | 44.6164 | 13775.23 | 0.00 | 10835.61 | 8664.48 |
| SPLIT MS2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MS2 | 10837.454 | 10837.454 | 0.581496 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:20:00 | 10837.45 | 10837.45 | 0.581496 | 19.63 | 13.78 | 0.00741690 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 8.9268 | 21.10 | 0.00752681 | 48.3569 | 1042.03 | 0.00 | 10851.70 | 10851.70 |
| SPLIT MS2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MS2 | 10837.454 | 10837.454 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:20:00 | 10837.45 | 10837.45 | 0.581496 | 19.63 | 13.78 | 0.00741690 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 8.9268 | 21.10 | 0.00752681 | 48.3569 | 1042.03 | 0.00 | -999.00 | -999.00 |
| SPLIT TSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TSW | 6984.287 | 5592.200 | 0.392115 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 6801.13 | 6018.75 | 0.392115 | 25.41 | 17.10 | 0.00876623 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 6.6191 | 24.00 | 0.00821587 | 44.2122 | 4614.48 | 0.00 | 6983.10 | 5585.44 |
| SPLIT TSW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TSW | 6984.287 | 6984.287 | 0.392115 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6984.29 | 6984.29 | 0.392115 | 20.01 | 14.14 | 0.00764625 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 6.6191 | 21.10 | 0.00781559 | 50.1896 | 1305.26 | 0.00 | 6993.47 | 6993.47 |
| SPLIT TSW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TSW | 6984.287 | 6984.287 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6984.29 | 6984.29 | 0.392115 | 20.01 | 14.14 | 0.00764625 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 6.6191 | 21.10 | 0.00781559 | 50.1896 | 1305.26 | 0.00 | -999.00 | -999.00 |
| SPLIT TNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TNW | 6776.999 | 5427.414 | 0.379559 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 6601.48 | 5832.85 | 0.379559 | 25.43 | 17.12 | 0.00877742 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 6.8381 | 24.00 | 0.00820834 | 44.1720 | 4469.40 | 0.00 | 6775.85 | 5420.64 |
| SPLIT TNW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TNW | 6776.999 | 6776.999 | 0.379559 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6777.00 | 6777.00 | 0.379559 | 19.97 | 14.33 | 0.00786188 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 6.8381 | 21.10 | 0.00805306 | 51.6940 | 1158.04 | 0.00 | 6785.90 | 6785.90 |
| SPLIT TNW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TNW | 6776.999 | 6776.999 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6777.00 | 6777.00 | 0.379559 | 19.97 | 14.33 | 0.00786188 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 6.8381 | 21.10 | 0.00805306 | 51.6940 | 1158.04 | 0.00 | -999.00 | -999.00 |
| SPLIT TSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TSE | 6327.961 | 5065.606 | 0.348850 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 6177.45 | 5384.82 | 0.348850 | 25.46 | 17.21 | 0.00887050 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 7.4400 | 24.00 | 0.00825477 | 44.4191 | 4115.28 | 0.00 | 6326.88 | 5060.09 |
| SPLIT TSE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TSE | 6327.961 | 6327.961 | 0.348850 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6327.96 | 6327.96 | 0.348850 | 19.87 | 14.07 | 0.00762539 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 7.4400 | 21.10 | 0.00781575 | 50.1906 | 1306.44 | 0.00 | 6336.28 | 6336.28 |
| SPLIT TSE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TSE | 6327.961 | 6327.961 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6327.96 | 6327.96 | 0.348850 | 19.87 | 14.07 | 0.00762539 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 7.4400 | 21.10 | 0.00781575 | 50.1906 | 1306.44 | 0.00 | -999.00 | -999.00 |
| SPLIT TNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TNE | 6119.015 | 4898.388 | 0.336334 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 5975.96 | 5199.39 | 0.336334 | 25.48 | 17.22 | 0.00888427 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 7.7169 | 24.00 | 0.00824487 | 44.3663 | 3971.31 | 0.00 | 6117.97 | 4892.76 |
| SPLIT TNE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TNE | 6119.015 | 6119.015 | 0.336334 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6119.01 | 6119.01 | 0.336334 | 19.83 | 14.25 | 0.00783726 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 7.7169 | 21.10 | 0.00805301 | 51.6936 | 1159.31 | 0.00 | 6127.06 | 6127.06 |
| SPLIT TNE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TNE | 6119.015 | 6119.015 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6119.01 | 6119.01 | 0.336334 | 19.83 | 14.25 | 0.00783726 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 7.7169 | 21.10 | 0.00805301 | 51.6936 | 1159.31 | 0.00 | -999.00 | -999.00 |
| SPLIT TN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TN1 | 5702.997 | 4563.948 | 0.312298 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 5572.65 | 4841.91 | 0.312298 | 25.52 | 17.24 | 0.00889575 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 8.3108 | 24.00 | 0.00820372 | 44.1472 | 3695.45 | 0.00 | 5702.03 | 4558.35 |
| SPLIT TN1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TN1 | 5702.997 | 5702.997 | 0.312298 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 5703.00 | 5703.00 | 0.312298 | 19.73 | 14.32 | 0.00795988 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 8.3108 | 21.10 | 0.00820486 | 52.6553 | 767.98 | 0.00 | 5710.49 | 5710.49 |
| SPLIT TN1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TN1 | 5702.997 | 5702.997 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 5703.00 | 5703.00 | 0.312298 | 19.73 | 14.32 | 0.00795988 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 8.3108 | 21.10 | 0.00820486 | 52.6553 | 767.98 | 0.00 | -999.00 | -999.00 |
| SPLIT TN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TN2 | 5681.794 | 4545.562 | 0.310904 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 5552.51 | 4821.50 | 0.310904 | 25.52 | 17.25 | 0.00890001 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 8.3481 | 24.00 | 0.00820498 | 44.1539 | 3679.47 | 0.00 | 5680.83 | 4539.92 |
| SPLIT TN2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TN2 | 5681.794 | 5681.794 | 0.310904 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 5681.79 | 5681.79 | 0.310904 | 19.72 | 14.32 | 0.00795877 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 8.3481 | 21.10 | 0.00820485 | 52.6552 | 768.01 | 0.00 | 5689.26 | 5689.26 |
| SPLIT TN2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TN2 | 5681.794 | 5681.794 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 5681.79 | 5681.79 | 0.310904 | 19.72 | 14.32 | 0.00795877 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 8.3481 | 21.10 | 0.00820485 | 52.6552 | 768.01 | 0.00 | -999.00 | -999.00 |
| SPLIT TS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TS1 | 5932.126 | 4748.065 | 0.325944 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 5793.78 | 5044.11 | 0.325944 | 25.50 | 17.22 | 0.00888083 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 7.9629 | 24.00 | 0.00821899 | 44.2286 | 3852.01 | 0.00 | 5931.12 | 4742.58 |
| SPLIT TS1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TS1 | 5932.126 | 5932.126 | 0.325944 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 5932.13 | 5932.13 | 0.325944 | 19.79 | 14.04 | 0.00763182 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 7.9629 | 21.10 | 0.00783727 | 50.3267 | 915.21 | 0.00 | 5939.92 | 5939.92 |
| SPLIT TS1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TS1 | 5932.126 | 5932.126 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 5932.13 | 5932.13 | 0.325944 | 19.79 | 14.04 | 0.00763182 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 7.9629 | 21.10 | 0.00783727 | 50.3267 | 915.21 | 0.00 | -999.00 | -999.00 |
| SPLIT TS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TS2 | 5910.996 | 4729.710 | 0.324546 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | 5773.73 | 5023.65 | 0.324546 | 25.50 | 17.23 | 0.00888502 | 12.80 | 11.59 | 0.00800000 | 30.82 | 0.01653057 | 24.33 | 7.9972 | 24.00 | 0.00822045 | 44.2364 | 3835.96 | 0.00 | 5909.99 | 4724.19 |
| SPLIT TS2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TS2 | 5910.996 | 5910.996 | 0.324546 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 5911.00 | 5911.00 | 0.324546 | 19.78 | 14.04 | 0.00763094 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 7.9972 | 21.10 | 0.00783727 | 50.3268 | 915.24 | 0.00 | 5918.76 | 5918.76 |
| SPLIT TS2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TS2 | 5910.996 | 5910.996 | -999.0 | -999.0 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 5911.00 | 5911.00 | 0.324546 | 19.78 | 14.04 | 0.00763094 | 40.00 | 21.17 | 0.00800000 | 4.60 | 0.00525715 | 4.60 | 7.9972 | 21.10 | 0.00783727 | 50.3268 | 915.24 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Coils| Coil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
| SPLIT GSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5811.377 | 4650.085 | 0.318135 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.3923 | 1004.8586 | 1.2032 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.318135 | 0.38276992 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 5678.74 | 4927.33 | 0.9772 | 0.38276992 | 0.318135 | 25.50 | 17.25 | 0.00890412 | 48315.4 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 356.346 | 5322.39 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 8.1583 | 24.04 | 0.00822666 | 24.00 | 0.00822666 | 44.2697 | 3760.27 | 0.00 | 5810.39 | 4644.35 | 0.36765340 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.32 | 14.10 | 0.00994116 | 39518.4 | |
| SPLIT GSW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5811.377 | 5811.377 | 0.318135 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.318135 | 0.38276992 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | Sensible | 5811.38 | 5811.38 | 1.0000 | 0.38276992 | 0.318135 | 19.75 | 13.99 | 0.00759310 | 39118.0 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5811.38 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 8.1583 | 21.10 | 0.00780060 | 21.10 | 0.00780060 | 50.0941 | 656.14 | 0.00 | 5819.01 | 5819.01 | 0.37600626 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.27 | 20.61 | 0.00875166 | 58919.9 | |
| SPLIT GSW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5811.377 | 5811.377 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.318135 | 0.38276992 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | Sensible | 5811.38 | 5811.38 | 1.0000 | 0.38276992 | 0.318135 | 19.75 | 13.99 | 0.00759310 | 39118.0 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5811.38 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 8.1583 | 21.10 | 0.00780060 | 21.10 | 0.00780060 | 50.0941 | 656.14 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5546.734 | 4442.313 | 0.302480 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.4247 | 1004.8586 | 1.2032 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.302480 | 0.36393429 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 5423.09 | 4694.56 | 0.9777 | 0.36393429 | 0.302480 | 25.53 | 17.27 | 0.00892154 | 48384.3 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 338.811 | 5084.28 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 8.5806 | 24.03 | 0.00820736 | 24.00 | 0.00820736 | 44.1667 | 3579.22 | 0.00 | 5545.79 | 4436.43 | 0.34956164 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.26 | 14.07 | 0.00994037 | 39457.4 | |
| SPLIT GNW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5546.734 | 5546.734 | 0.302480 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.302480 | 0.36393429 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | Sensible | 5546.73 | 5546.73 | 1.0000 | 0.36393429 | 0.302480 | 19.68 | 14.39 | 0.00804679 | 40198.6 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5546.73 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 8.5806 | 21.10 | 0.00830862 | 21.10 | 0.00830862 | 53.3124 | 536.07 | 0.00 | 5554.02 | 5554.02 | 0.35750346 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.33 | 20.63 | 0.00875166 | 58979.7 | |
| SPLIT GNW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5546.734 | 5546.734 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.302480 | 0.36393429 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | Sensible | 5546.73 | 5546.73 | 1.0000 | 0.36393429 | 0.302480 | 19.68 | 14.39 | 0.00804679 | 40198.6 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5546.73 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 8.5806 | 21.10 | 0.00830862 | 21.10 | 0.00830862 | 53.3124 | 536.07 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT OFFICE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6706.827 | 5365.639 | 0.368100 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.4717 | 1004.8586 | 1.2032 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.368100 | 0.44288589 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 11:40:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 11:40:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 09:20:00 | Sensible | 6592.51 | 5681.62 | 0.9830 | 0.44288589 | 0.368100 | 25.44 | 17.26 | 0.00894681 | 48364.5 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 412.312 | 6180.20 | 30.00 | 0.01652904 | 24.11 | 0.03810604 | 10.3521 | 23.90 | 0.00807125 | 23.90 | 0.00806581 | 43.6752 | 4112.11 | 0.00 | 6705.69 | 5359.34 | 0.42539525 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.36 | 14.11 | 0.00994376 | 39559.0 | |
| SPLIT OFFICE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 6706.827 | 6706.827 | 0.368100 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.368100 | 0.44288589 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | Sensible | 6706.83 | 6706.83 | 1.0000 | 0.44288589 | 0.368100 | 19.39 | 13.86 | 0.00760289 | 38774.1 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6706.83 | 4.60 | 0.00525715 | 4.60 | 0.03810604 | 10.3521 | 21.10 | 0.00787376 | 21.10 | 0.00787376 | 50.5579 | 1048.99 | 0.00 | 6715.64 | 6715.64 | 0.43505996 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.23 | 20.60 | 0.00875166 | 58880.2 | |
| SPLIT OFFICE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6706.827 | 6706.827 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.368100 | 0.44288589 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | Sensible | 6706.83 | 6706.83 | 1.0000 | 0.44288589 | 0.368100 | 19.39 | 13.86 | 0.00760289 | 38774.1 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6706.83 | 4.60 | 0.00525715 | 4.60 | 0.03810604 | 10.3521 | 21.10 | 0.00787376 | 21.10 | 0.00787376 | 50.5579 | 1048.99 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5222.695 | 4179.084 | 0.280767 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.5833 | 1004.8586 | 1.2032 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.280767 | 0.33780974 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 5116.55 | 4376.39 | 0.9797 | 0.33780974 | 0.280767 | 25.56 | 17.35 | 0.00900685 | 48640.5 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 314.490 | 4802.06 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 9.2442 | 24.02 | 0.00824051 | 24.00 | 0.00824051 | 44.3430 | 3328.98 | 0.00 | 5221.81 | 4173.78 | 0.32446881 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.10 | 13.99 | 0.00991826 | 39229.0 | |
| SPLIT GNE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5222.695 | 5222.695 | 0.280767 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.280767 | 0.33780974 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | Sensible | 5222.70 | 5222.70 | 1.0000 | 0.33780974 | 0.280767 | 19.57 | 14.33 | 0.00802615 | 40034.6 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5222.70 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 9.2442 | 21.10 | 0.00830819 | 21.10 | 0.00830819 | 53.3096 | 537.04 | 0.00 | 5229.56 | 5229.56 | 0.33184054 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.54 | 20.70 | 0.00875166 | 59203.4 | |
| SPLIT GNE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5222.695 | 5222.695 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.280767 | 0.33780974 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | Sensible | 5222.70 | 5222.70 | 1.0000 | 0.33780974 | 0.280767 | 19.57 | 14.33 | 0.00802615 | 40034.6 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5222.70 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 9.2442 | 21.10 | 0.00830819 | 21.10 | 0.00830819 | 53.3096 | 537.04 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 4668.563 | 3723.814 | 0.245959 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.8028 | 1004.8586 | 1.2032 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.245959 | 0.29593029 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 4586.92 | 3860.70 | 0.9825 | 0.29593029 | 0.245959 | 25.63 | 17.47 | 0.00912494 | 49011.4 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 275.501 | 4311.42 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 10.5524 | 24.00 | 0.00825128 | 24.00 | 0.00825128 | 44.4001 | 2927.28 | 0.00 | 4667.77 | 3719.69 | 0.28424328 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.88 | 13.86 | 0.00987691 | 38900.6 | |
| SPLIT GN1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 4668.563 | 4668.563 | 0.245959 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.245959 | 0.29593029 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:20:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:30:00 | Sensible | 4668.56 | 4668.56 | 1.0000 | 0.29593029 | 0.245959 | 19.36 | 14.62 | 0.00843069 | 40840.8 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 4668.56 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 10.5524 | 21.10 | 0.00880508 | 21.10 | 0.00872559 | 55.9508 | 199.62 | 0.00 | 4674.70 | 4674.70 | 0.29070111 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.86 | 20.79 | 0.00875166 | 59524.9 | |
| SPLIT GN1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 4668.563 | 4668.563 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.245959 | 0.29593029 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:20:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:30:00 | Sensible | 4668.56 | 4668.56 | 1.0000 | 0.29593029 | 0.245959 | 19.36 | 14.62 | 0.00843069 | 40840.8 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 4668.56 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 10.5524 | 21.10 | 0.00880508 | 21.10 | 0.00872559 | 55.9508 | 199.62 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 4662.410 | 3718.462 | 0.245562 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.8062 | 1004.8586 | 1.2032 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.245562 | 0.29545258 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 4581.07 | 3854.83 | 0.9826 | 0.29545258 | 0.245562 | 25.63 | 17.48 | 0.00912675 | 49016.9 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 275.056 | 4306.02 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 10.5694 | 24.00 | 0.00825172 | 24.00 | 0.00825172 | 44.4025 | 2922.72 | 0.00 | 4661.62 | 3714.30 | 0.28378444 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.87 | 13.86 | 0.00987585 | 38895.8 | |
| SPLIT GN2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 4662.410 | 4662.410 | 0.245562 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.245562 | 0.29545258 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 4662.41 | 4662.41 | 1.0000 | 0.29545258 | 0.245562 | 19.36 | 14.62 | 0.00843001 | 40836.2 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 4662.41 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 10.5694 | 21.10 | 0.00880500 | 21.10 | 0.00871857 | 55.9065 | 194.00 | 0.00 | 4668.54 | 4668.54 | 0.29023184 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.86 | 20.79 | 0.00875166 | 59529.6 | |
| SPLIT GN2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 4662.410 | 4662.410 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.245562 | 0.29545258 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 4662.41 | 4662.41 | 1.0000 | 0.29545258 | 0.245562 | 19.36 | 14.62 | 0.00843001 | 40836.2 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 4662.41 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 10.5694 | 21.10 | 0.00880500 | 21.10 | 0.00871857 | 55.9065 | 194.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5025.485 | 4022.572 | 0.266249 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.7555 | 1004.8586 | 1.2032 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.266249 | 0.32034173 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 4933.56 | 4165.70 | 0.9817 | 0.32034173 | 0.266249 | 25.59 | 17.44 | 0.00909951 | 48906.7 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 298.227 | 4635.33 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 9.7482 | 24.02 | 0.00829687 | 24.00 | 0.00829687 | 44.6430 | 3162.37 | 0.00 | 5024.63 | 4012.53 | 0.30769065 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.92 | 13.90 | 0.00989498 | 38992.3 | |
| SPLIT GS1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5025.485 | 5025.485 | 0.266249 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.266249 | 0.32034173 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 5025.49 | 5025.49 | 1.0000 | 0.32034173 | 0.266249 | 19.49 | 13.82 | 0.00751512 | 38652.9 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5025.49 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 9.7482 | 21.10 | 0.00775900 | 21.10 | 0.00772086 | 49.5882 | 306.49 | 0.00 | 5032.09 | 5032.09 | 0.31468119 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.77 | 20.76 | 0.00875166 | 59435.2 | |
| SPLIT GS1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5025.485 | 5025.485 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.266249 | 0.32034173 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 5025.49 | 5025.49 | 1.0000 | 0.32034173 | 0.266249 | 19.49 | 13.82 | 0.00751512 | 38652.9 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5025.49 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 9.7482 | 21.10 | 0.00775900 | 21.10 | 0.00772086 | 49.5882 | 306.49 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5068.797 | 4055.606 | 0.269108 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.7322 | 1004.8586 | 1.2032 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.269108 | 0.32378153 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 4974.58 | 4207.54 | 0.9814 | 0.32378153 | 0.269108 | 25.59 | 17.43 | 0.00908695 | 48868.0 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 301.430 | 4673.15 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 9.6447 | 24.02 | 0.00829240 | 24.00 | 0.00829240 | 44.6193 | 3195.10 | 0.00 | 5067.93 | 4050.63 | 0.31099460 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.94 | 13.91 | 0.00990213 | 39026.5 | |
| SPLIT GS2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5068.797 | 5068.797 | 0.269108 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.269108 | 0.32378153 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 17:40:00 | Sensible | 5068.80 | 5068.80 | 1.0000 | 0.32378153 | 0.269108 | 19.51 | 13.83 | 0.00752571 | 38697.2 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5068.80 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 9.6447 | 21.10 | 0.00776786 | 21.10 | 0.00773168 | 49.6568 | 318.63 | 0.00 | 5075.46 | 5075.46 | 0.31806021 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.74 | 20.75 | 0.00875166 | 59401.6 | |
| SPLIT GS2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5068.797 | 5068.797 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.269108 | 0.32378153 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 17:40:00 | Sensible | 5068.80 | 5068.80 | 1.0000 | 0.32378153 | 0.269108 | 19.51 | 13.83 | 0.00752571 | 38697.2 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5068.80 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 9.6447 | 21.10 | 0.00776786 | 21.10 | 0.00773168 | 49.6568 | 318.63 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 12723.099 | 10181.550 | 0.705021 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.2709 | 1004.8586 | 1.2032 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.705021 | 0.84825744 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 12411.70 | 10869.11 | 0.9755 | 0.84825744 | 0.705021 | 25.45 | 17.18 | 0.00883883 | 48101.7 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 789.699 | 11622.00 | 30.82 | 0.01653057 | 24.33 | 0.05190911 | 7.3628 | 24.04 | 0.00822749 | 24.00 | 0.00822749 | 44.2741 | 16623.84 | 0.00 | 12720.93 | 10167.21 | 0.81475768 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.47 | 14.17 | 0.00995576 | 39709.2 | |
| SPLIT MSW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 12723.099 | 12723.099 | 0.705021 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.705021 | 0.84825744 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 12723.10 | 12723.10 | 1.0000 | 0.84825744 | 0.705021 | 19.88 | 14.01 | 0.00755502 | 39155.1 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12723.10 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 7.3628 | 21.10 | 0.00773765 | 21.10 | 0.00773765 | 49.6950 | 2786.63 | 0.00 | 12739.82 | 12739.82 | 0.83326846 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.08 | 20.56 | 0.00875166 | 58733.1 | |
| SPLIT MSW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 12723.099 | 12723.099 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.705021 | 0.84825744 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 12723.10 | 12723.10 | 1.0000 | 0.84825744 | 0.705021 | 19.88 | 14.01 | 0.00755502 | 39155.1 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12723.10 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 7.3628 | 21.10 | 0.00773765 | 21.10 | 0.00773765 | 49.6950 | 2786.63 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 12174.354 | 9747.996 | 0.671528 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.3128 | 1004.8586 | 1.2032 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.671528 | 0.80796066 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 11883.98 | 10374.35 | 0.9761 | 0.80796066 | 0.671528 | 25.48 | 17.20 | 0.00886135 | 48182.1 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 752.184 | 11131.79 | 30.82 | 0.01653057 | 24.33 | 0.05190911 | 7.7300 | 24.04 | 0.00821886 | 24.00 | 0.00821886 | 44.2280 | 15855.55 | 0.00 | 12172.28 | 9737.47 | 0.77605232 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.41 | 14.14 | 0.00995454 | 39637.5 | |
| SPLIT MNW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 12174.354 | 12174.354 | 0.671528 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.671528 | 0.80796066 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 12174.35 | 12174.35 | 1.0000 | 0.80796066 | 0.671528 | 19.82 | 14.37 | 0.00796943 | 40145.4 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12174.35 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 7.7300 | 21.10 | 0.00819666 | 21.10 | 0.00819666 | 52.6035 | 2240.27 | 0.00 | 12190.35 | 12190.35 | 0.79368375 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.15 | 20.58 | 0.00875166 | 58803.3 | |
| SPLIT MNW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 12174.354 | 12174.354 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.671528 | 0.80796066 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 12174.35 | 12174.35 | 1.0000 | 0.80796066 | 0.671528 | 19.82 | 14.37 | 0.00796943 | 40145.4 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12174.35 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 7.7300 | 21.10 | 0.00819666 | 21.10 | 0.00819666 | 52.6035 | 2240.27 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 11866.128 | 9502.375 | 0.646921 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.4500 | 1004.8586 | 1.2032 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.646921 | 0.77835379 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 11601.83 | 10020.57 | 0.9777 | 0.77835379 | 0.646921 | 25.49 | 17.27 | 0.00893515 | 48387.6 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 724.621 | 10877.21 | 30.82 | 0.01653057 | 24.33 | 0.05190911 | 8.0240 | 24.04 | 0.00827252 | 24.00 | 0.00827252 | 44.5136 | 15289.67 | 0.00 | 11864.11 | 9489.73 | 0.74761470 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.26 | 14.07 | 0.00993945 | 39453.1 | |
| SPLIT MSE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 11866.128 | 11866.128 | 0.646921 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.646921 | 0.77835379 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 11866.13 | 11866.13 | 1.0000 | 0.77835379 | 0.646921 | 19.78 | 13.95 | 0.00753903 | 39003.4 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11866.13 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 8.0240 | 21.10 | 0.00773810 | 21.10 | 0.00773810 | 49.6979 | 2791.38 | 0.00 | 11881.72 | 11881.72 | 0.76460003 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.33 | 20.63 | 0.00875166 | 58983.9 | |
| SPLIT MSE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 11866.128 | 11866.128 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.646921 | 0.77835379 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 11866.13 | 11866.13 | 1.0000 | 0.77835379 | 0.646921 | 19.78 | 13.95 | 0.00753903 | 39003.4 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11866.13 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 8.0240 | 21.10 | 0.00773810 | 21.10 | 0.00773810 | 49.6979 | 2791.38 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 11317.735 | 9056.393 | 0.614042 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.4956 | 1004.8586 | 1.2032 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.614042 | 0.73879450 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 11073.24 | 9532.04 | 0.9784 | 0.73879450 | 0.614042 | 25.52 | 17.30 | 0.00895969 | 48474.4 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 687.793 | 10385.45 | 30.82 | 0.01653057 | 24.33 | 0.05190911 | 8.4537 | 24.03 | 0.00826057 | 24.00 | 0.00826057 | 44.4498 | 14527.18 | 0.00 | 11315.81 | 9043.29 | 0.70961770 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.21 | 14.04 | 0.00992905 | 39376.0 | |
| SPLIT MNE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 11317.735 | 11317.735 | 0.614042 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.614042 | 0.73879450 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 11317.74 | 11317.74 | 1.0000 | 0.73879450 | 0.614042 | 19.71 | 14.30 | 0.00794787 | 39968.9 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11317.74 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 8.4537 | 21.10 | 0.00819634 | 21.10 | 0.00819634 | 52.6015 | 2245.25 | 0.00 | 11332.61 | 11332.61 | 0.72573977 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.40 | 20.65 | 0.00875166 | 59059.4 | |
| SPLIT MNE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 11317.735 | 11317.735 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.614042 | 0.73879450 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 11317.74 | 11317.74 | 1.0000 | 0.73879450 | 0.614042 | 19.71 | 14.30 | 0.00794787 | 39968.9 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11317.74 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 8.4537 | 21.10 | 0.00819634 | 21.10 | 0.00819634 | 52.6015 | 2245.25 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 10244.583 | 8201.720 | 0.546385 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.6767 | 1004.8586 | 1.2032 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.546385 | 0.65739231 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 10047.65 | 8533.87 | 0.9808 | 0.65739231 | 0.546385 | 25.58 | 17.40 | 0.00905712 | 48784.6 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 612.010 | 9435.64 | 30.82 | 0.01653057 | 24.33 | 0.05190911 | 9.5005 | 24.02 | 0.00827257 | 24.00 | 0.00827257 | 44.5135 | 12967.78 | 0.00 | 10242.84 | 8192.91 | 0.63143028 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.99 | 13.94 | 0.00991179 | 39100.7 | |
| SPLIT MN1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 10244.583 | 10244.583 | 0.546385 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.546385 | 0.65739231 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:20:00 | Sensible | 10244.58 | 10244.58 | 1.0000 | 0.65739231 | 0.546385 | 19.53 | 14.67 | 0.00841206 | 40970.6 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10244.58 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 9.5005 | 21.10 | 0.00874325 | 21.10 | 0.00863973 | 55.4081 | 569.59 | 0.00 | 10258.05 | 10258.05 | 0.64577598 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.67 | 20.73 | 0.00875166 | 59328.9 | |
| SPLIT MN1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10244.583 | 10244.583 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.546385 | 0.65739231 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:20:00 | Sensible | 10244.58 | 10244.58 | 1.0000 | 0.65739231 | 0.546385 | 19.53 | 14.67 | 0.00841206 | 40970.6 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10244.58 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 9.5005 | 21.10 | 0.00874325 | 21.10 | 0.00863973 | 55.4081 | 569.59 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 10228.452 | 8187.822 | 0.545363 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.6800 | 1004.8586 | 1.2032 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.545363 | 0.65616254 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 10032.25 | 8518.76 | 0.9808 | 0.65616254 | 0.545363 | 25.58 | 17.40 | 0.00905886 | 48790.0 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 610.865 | 9421.39 | 30.82 | 0.01653057 | 24.33 | 0.05190911 | 9.5183 | 24.02 | 0.00827287 | 24.00 | 0.00827287 | 44.5151 | 12944.29 | 0.00 | 10226.71 | 8178.93 | 0.63024908 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.98 | 13.94 | 0.00991074 | 39095.9 | |
| SPLIT MN2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 10228.452 | 10228.452 | 0.545363 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.545363 | 0.65616254 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 10228.45 | 10228.45 | 1.0000 | 0.65616254 | 0.545363 | 19.53 | 14.66 | 0.00841135 | 40965.9 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10228.45 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 9.5183 | 21.10 | 0.00874316 | 21.10 | 0.00863964 | 55.4075 | 569.71 | 0.00 | 10241.89 | 10241.89 | 0.64456794 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.67 | 20.73 | 0.00875166 | 59333.6 | |
| SPLIT MN2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10228.452 | 10228.452 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.545363 | 0.65616254 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 10228.45 | 10228.45 | 1.0000 | 0.65616254 | 0.545363 | 19.53 | 14.66 | 0.00841135 | 40965.9 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10228.45 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 9.5183 | 21.10 | 0.00874316 | 21.10 | 0.00863964 | 55.4075 | 569.71 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 10851.740 | 8688.448 | 0.582439 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.6180 | 1004.8586 | 1.2032 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.582439 | 0.70077126 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 10633.46 | 9069.22 | 0.9799 | 0.70077126 | 0.582439 | 25.54 | 17.36 | 0.00902550 | 48668.6 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 652.394 | 9981.06 | 30.82 | 0.01653057 | 24.33 | 0.05190911 | 8.9124 | 24.03 | 0.00829118 | 24.00 | 0.00829118 | 44.6127 | 13796.96 | 0.00 | 10849.89 | 8677.06 | 0.67309609 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.07 | 13.98 | 0.00991899 | 39203.0 | |
| SPLIT MS1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 10851.740 | 10851.740 | 0.582439 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.582439 | 0.70077126 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 10851.74 | 10851.74 | 1.0000 | 0.70077126 | 0.582439 | 19.63 | 13.78 | 0.00741721 | 38545.0 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10851.74 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 8.9124 | 21.10 | 0.00762856 | 21.10 | 0.00752676 | 48.3566 | 1041.91 | 0.00 | 10866.00 | 10866.00 | 0.68838841 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.57 | 20.70 | 0.00875166 | 59228.8 | |
| SPLIT MS1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10851.740 | 10851.740 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.582439 | 0.70077126 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 10851.74 | 10851.74 | 1.0000 | 0.70077126 | 0.582439 | 19.63 | 13.78 | 0.00741721 | 38545.0 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10851.74 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 8.9124 | 21.10 | 0.00762856 | 21.10 | 0.00752676 | 48.3566 | 1041.91 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 10837.454 | 8675.940 | 0.581496 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.6213 | 1004.8586 | 1.2032 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.581496 | 0.69963706 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 10619.91 | 9055.39 | 0.9799 | 0.69963706 | 0.581496 | 25.54 | 17.36 | 0.00902732 | 48674.0 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 651.339 | 9968.58 | 30.82 | 0.01653057 | 24.33 | 0.05190911 | 8.9268 | 24.03 | 0.00829187 | 24.00 | 0.00829187 | 44.6164 | 13775.23 | 0.00 | 10835.61 | 8664.48 | 0.67200668 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.07 | 13.98 | 0.00991793 | 39198.1 | |
| SPLIT MS2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 10837.454 | 10837.454 | 0.581496 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.581496 | 0.69963706 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:20:00 | Sensible | 10837.45 | 10837.45 | 1.0000 | 0.69963706 | 0.581496 | 19.63 | 13.78 | 0.00741690 | 38541.8 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10837.45 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 8.9268 | 21.10 | 0.00762859 | 21.10 | 0.00752681 | 48.3569 | 1042.03 | 0.00 | 10851.70 | 10851.70 | 0.68727426 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.57 | 20.70 | 0.00875166 | 59233.6 | |
| SPLIT MS2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10837.454 | 10837.454 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.581496 | 0.69963706 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 08:20:00 | Sensible | 10837.45 | 10837.45 | 1.0000 | 0.69963706 | 0.581496 | 19.63 | 13.78 | 0.00741690 | 38541.8 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10837.45 | 4.60 | 0.00525715 | 4.60 | 0.05190911 | 8.9268 | 21.10 | 0.00762859 | 21.10 | 0.00752681 | 48.3569 | 1042.03 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6984.287 | 5592.200 | 0.392115 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.1360 | 1004.8586 | 1.2032 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.392115 | 0.47177992 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 6801.13 | 6018.75 | 0.9738 | 0.47177992 | 0.392115 | 25.41 | 17.10 | 0.00876623 | 47875.6 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 439.211 | 6361.92 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 6.6191 | 24.06 | 0.00821587 | 24.00 | 0.00821587 | 44.2122 | 4614.48 | 0.00 | 6983.10 | 5585.44 | 0.45314818 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.62 | 14.24 | 0.00997537 | 39912.2 | |
| SPLIT TSW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 6984.287 | 6984.287 | 0.392115 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.392115 | 0.47177992 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 6984.29 | 6984.29 | 1.0000 | 0.47177992 | 0.392115 | 20.01 | 14.14 | 0.00764625 | 39511.6 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6984.29 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 6.6191 | 21.10 | 0.00781559 | 21.10 | 0.00781559 | 50.1896 | 1305.26 | 0.00 | 6993.47 | 6993.47 | 0.46344342 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 35.89 | 20.50 | 0.00875166 | 58534.3 | |
| SPLIT TSW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6984.287 | 6984.287 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.392115 | 0.47177992 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 6984.29 | 6984.29 | 1.0000 | 0.47177992 | 0.392115 | 20.01 | 14.14 | 0.00764625 | 39511.6 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6984.29 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 6.6191 | 21.10 | 0.00781559 | 21.10 | 0.00781559 | 50.1896 | 1305.26 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6776.999 | 5427.414 | 0.379559 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.1568 | 1004.8586 | 1.2032 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.379559 | 0.45667249 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 6601.48 | 5832.85 | 0.9741 | 0.45667249 | 0.379559 | 25.43 | 17.12 | 0.00877742 | 47917.4 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 425.147 | 6176.33 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 6.8381 | 24.05 | 0.00820834 | 24.00 | 0.00820834 | 44.1720 | 4469.40 | 0.00 | 6775.85 | 5420.64 | 0.43863738 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.59 | 14.23 | 0.00997331 | 39874.9 | |
| SPLIT TNW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 6776.999 | 6776.999 | 0.379559 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.379559 | 0.45667249 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 6777.00 | 6777.00 | 1.0000 | 0.45667249 | 0.379559 | 19.97 | 14.33 | 0.00786188 | 40022.4 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6777.00 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 6.8381 | 21.10 | 0.00805306 | 21.10 | 0.00805306 | 51.6940 | 1158.04 | 0.00 | 6785.90 | 6785.90 | 0.44860294 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 35.93 | 20.51 | 0.00875166 | 58570.9 | |
| SPLIT TNW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6776.999 | 6776.999 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.379559 | 0.45667249 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 6777.00 | 6777.00 | 1.0000 | 0.45667249 | 0.379559 | 19.97 | 14.33 | 0.00786188 | 40022.4 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6777.00 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 6.8381 | 21.10 | 0.00805306 | 21.10 | 0.00805306 | 51.6940 | 1158.04 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6327.961 | 5065.606 | 0.348850 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.3298 | 1004.8586 | 1.2032 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.348850 | 0.41972532 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 6177.45 | 5384.82 | 0.9762 | 0.41972532 | 0.348850 | 25.46 | 17.21 | 0.00887050 | 48191.2 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 390.750 | 5786.70 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 7.4400 | 24.05 | 0.00825477 | 24.00 | 0.00825477 | 44.4191 | 4115.28 | 0.00 | 6326.88 | 5060.09 | 0.40314934 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.40 | 14.14 | 0.00995266 | 39628.7 | |
| SPLIT TSE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 6327.961 | 6327.961 | 0.348850 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.348850 | 0.41972532 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 6327.96 | 6327.96 | 1.0000 | 0.41972532 | 0.348850 | 19.87 | 14.07 | 0.00762539 | 39320.7 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6327.96 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 7.4400 | 21.10 | 0.00781575 | 21.10 | 0.00781575 | 50.1906 | 1306.44 | 0.00 | 6336.28 | 6336.28 | 0.41230864 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.16 | 20.58 | 0.00875166 | 58811.9 | |
| SPLIT TSE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6327.961 | 6327.961 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.348850 | 0.41972532 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 6327.96 | 6327.96 | 1.0000 | 0.41972532 | 0.348850 | 19.87 | 14.07 | 0.00762539 | 39320.7 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6327.96 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 7.4400 | 21.10 | 0.00781575 | 21.10 | 0.00781575 | 50.1906 | 1306.44 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6119.015 | 4898.388 | 0.336334 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.3554 | 1004.8586 | 1.2032 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.336334 | 0.40466566 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 5975.96 | 5199.39 | 0.9766 | 0.40466566 | 0.336334 | 25.48 | 17.22 | 0.00888427 | 48243.6 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 376.730 | 5599.23 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 7.7169 | 24.05 | 0.00824487 | 24.00 | 0.00824487 | 44.3663 | 3971.31 | 0.00 | 6117.97 | 4892.76 | 0.38868443 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.37 | 14.12 | 0.00994875 | 39582.2 | |
| SPLIT TNE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 6119.015 | 6119.015 | 0.336334 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.336334 | 0.40466566 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 6119.01 | 6119.01 | 1.0000 | 0.40466566 | 0.336334 | 19.83 | 14.25 | 0.00783726 | 39812.1 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6119.01 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 7.7169 | 21.10 | 0.00805301 | 21.10 | 0.00805301 | 51.6936 | 1159.31 | 0.00 | 6127.06 | 6127.06 | 0.39751509 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.21 | 20.59 | 0.00875166 | 58857.5 | |
| SPLIT TNE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6119.015 | 6119.015 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.336334 | 0.40466566 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 6119.01 | 6119.01 | 1.0000 | 0.40466566 | 0.336334 | 19.83 | 14.25 | 0.00783726 | 39812.1 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6119.01 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 7.7169 | 21.10 | 0.00805301 | 21.10 | 0.00805301 | 51.6936 | 1159.31 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5702.997 | 4563.948 | 0.312298 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.3767 | 1004.8586 | 1.2032 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.312298 | 0.37574707 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 5572.65 | 4841.91 | 0.9771 | 0.37574707 | 0.312298 | 25.52 | 17.24 | 0.00889575 | 48310.8 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 349.808 | 5222.84 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 8.3108 | 24.04 | 0.00820372 | 24.00 | 0.00820372 | 44.1472 | 3695.45 | 0.00 | 5702.03 | 4558.35 | 0.36090790 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.32 | 14.10 | 0.00994221 | 39523.3 | |
| SPLIT TN1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5702.997 | 5702.997 | 0.312298 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.312298 | 0.37574707 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 5703.00 | 5703.00 | 1.0000 | 0.37574707 | 0.312298 | 19.73 | 14.32 | 0.00795988 | 40023.5 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5703.00 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 8.3108 | 21.10 | 0.00820486 | 21.10 | 0.00820486 | 52.6553 | 767.98 | 0.00 | 5710.49 | 5710.49 | 0.36910751 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.26 | 20.61 | 0.00875166 | 58915.2 | |
| SPLIT TN1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5702.997 | 5702.997 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.312298 | 0.37574707 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 5703.00 | 5703.00 | 1.0000 | 0.37574707 | 0.312298 | 19.73 | 14.32 | 0.00795988 | 40023.5 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5703.00 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 8.3108 | 21.10 | 0.00820486 | 21.10 | 0.00820486 | 52.6553 | 767.98 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5681.794 | 4545.562 | 0.310904 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.3847 | 1004.8586 | 1.2032 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.310904 | 0.37406990 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 5552.51 | 4821.50 | 0.9772 | 0.37406990 | 0.310904 | 25.52 | 17.25 | 0.00890001 | 48324.0 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 348.247 | 5204.27 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 8.3481 | 24.04 | 0.00820498 | 24.00 | 0.00820498 | 44.1539 | 3679.47 | 0.00 | 5680.83 | 4539.92 | 0.35929697 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.32 | 14.09 | 0.00993966 | 39511.4 | |
| SPLIT TN2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5681.794 | 5681.794 | 0.310904 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.310904 | 0.37406990 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 5681.79 | 5681.79 | 1.0000 | 0.37406990 | 0.310904 | 19.72 | 14.32 | 0.00795877 | 40014.4 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5681.79 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 8.3481 | 21.10 | 0.00820485 | 21.10 | 0.00820485 | 52.6552 | 768.01 | 0.00 | 5689.26 | 5689.26 | 0.36745997 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.27 | 20.61 | 0.00875166 | 58926.8 | |
| SPLIT TN2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5681.794 | 5681.794 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.310904 | 0.37406990 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 5681.79 | 5681.79 | 1.0000 | 0.37406990 | 0.310904 | 19.72 | 14.32 | 0.00795877 | 40014.4 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5681.79 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 8.3481 | 21.10 | 0.00820485 | 21.10 | 0.00820485 | 52.6552 | 768.01 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5932.126 | 4748.065 | 0.325944 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.3490 | 1004.8586 | 1.2032 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.325944 | 0.39216493 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 5793.78 | 5044.11 | 0.9767 | 0.39216493 | 0.325944 | 25.50 | 17.22 | 0.00888083 | 48250.7 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 365.092 | 5428.69 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 7.9629 | 24.05 | 0.00821899 | 24.00 | 0.00821899 | 44.2286 | 3852.01 | 0.00 | 5931.12 | 4742.58 | 0.37667738 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.36 | 14.12 | 0.00994753 | 39576.5 | |
| SPLIT TS1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5932.126 | 5932.126 | 0.325944 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.325944 | 0.39216493 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 5932.13 | 5932.13 | 1.0000 | 0.39216493 | 0.325944 | 19.79 | 14.04 | 0.00763182 | 39249.1 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5932.13 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 7.9629 | 21.10 | 0.00783727 | 21.10 | 0.00783727 | 50.3267 | 915.21 | 0.00 | 5939.92 | 5939.92 | 0.38523525 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.21 | 20.59 | 0.00875166 | 58863.0 | |
| SPLIT TS1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5932.126 | 5932.126 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.325944 | 0.39216493 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 5932.13 | 5932.13 | 1.0000 | 0.39216493 | 0.325944 | 19.79 | 14.04 | 0.00763182 | 39249.1 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5932.13 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 7.9629 | 21.10 | 0.00783727 | 21.10 | 0.00783727 | 50.3267 | 915.21 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5910.996 | 4729.710 | 0.324546 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.3568 | 1004.8586 | 1.2032 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.324546 | 0.39048275 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 19:00:00 | Sensible | 5773.73 | 5023.65 | 0.9768 | 0.39048275 | 0.324546 | 25.50 | 17.23 | 0.00888502 | 48263.5 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 363.526 | 5410.20 | 30.82 | 0.01653057 | 24.33 | 0.02595455 | 7.9972 | 24.04 | 0.00822045 | 24.00 | 0.00822045 | 44.2364 | 3835.96 | 0.00 | 5909.99 | 4724.19 | 0.37506164 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.36 | 14.11 | 0.00994506 | 39565.0 | |
| SPLIT TS2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5910.996 | 5910.996 | 0.324546 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.324546 | 0.39048275 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 5911.00 | 5911.00 | 1.0000 | 0.39048275 | 0.324546 | 19.78 | 14.04 | 0.00763094 | 39241.1 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5911.00 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 7.9972 | 21.10 | 0.00783727 | 21.10 | 0.00783727 | 50.3268 | 915.24 | 0.00 | 5918.76 | 5918.76 | 0.38358280 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.22 | 20.60 | 0.00875166 | 58874.3 | |
| SPLIT TS2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5910.996 | 5910.996 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2032 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.324546 | 0.39048275 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 5911.00 | 5911.00 | 1.0000 | 0.39048275 | 0.324546 | 19.78 | 14.04 | 0.00763094 | 39241.1 | 40.00 | 21.17 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5911.00 | 4.60 | 0.00525715 | 4.60 | 0.02595455 | 7.9972 | 21.10 | 0.00783727 | 21.10 | 0.00783727 | 50.3268 | 915.24 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Economizer| High Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
| None |
| Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
| None |
| Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
| G SW APARTMENT | 4760.83 | 1232.33 | 516.50 |
| G NW APARTMENT | 6428.33 | 2648.50 | 963.50 |
| OFFICE | 1387.00 | 153.33 | 20.33 |
| G NE APARTMENT | 6427.33 | 2627.67 | 963.00 |
| G N1 APARTMENT | 6466.00 | 2470.17 | 983.17 |
| G N2 APARTMENT | 6466.00 | 2466.67 | 981.83 |
| G S1 APARTMENT | 4859.50 | 1044.50 | 555.33 |
| G S2 APARTMENT | 4868.67 | 851.67 | 359.67 |
| M SW APARTMENT | 4806.50 | 1148.33 | 501.50 |
| M NW APARTMENT | 6577.17 | 2372.17 | 921.33 |
| M SE APARTMENT | 4798.33 | 1177.83 | 521.00 |
| M NE APARTMENT | 6589.83 | 2365.67 | 931.83 |
| M N1 APARTMENT | 6578.33 | 2353.67 | 1079.50 |
| M N2 APARTMENT | 6582.83 | 2352.67 | 1078.17 |
| M S1 APARTMENT | 4861.67 | 1063.83 | 600.67 |
| M S2 APARTMENT | 4860.33 | 1063.83 | 600.00 |
| T SW APARTMENT | 4624.67 | 2260.00 | 1162.17 |
| T NW APARTMENT | 6596.33 | 3618.00 | 1863.83 |
| T SE APARTMENT | 4622.00 | 2301.67 | 1198.83 |
| T NE APARTMENT | 6598.67 | 3639.17 | 1877.83 |
| T N1 APARTMENT | 6482.83 | 3491.83 | 1693.00 |
| T N2 APARTMENT | 6485.17 | 3494.50 | 1692.83 |
| T S1 APARTMENT | 4645.50 | 2045.50 | 1042.33 |
| T S2 APARTMENT | 4645.33 | 2047.00 | 1043.67 |
| T CORRIDOR | 8760.00 | 8760.00 | 8760.00 |
| G CORRIDOR | 7422.33 | 7047.67 | 6111.50 |
| M CORRIDOR | 8760.00 | 8760.00 | 8760.00 |
| Facility | 8760.00 | 8760.00 | 8760.00 |
| During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
| G SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 0.00 | 29.33 | 0.00 | 0.00 |
| G NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| Facility | 0.00 | 29.33 | 0.00 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Average Outdoor Air During Occupied Hours| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| G SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.356 | 0.032 | 0.000 | 0.045 |
| G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.034 | 0.000 | 0.057 |
| OFFICE | 4.75 | 4.75 | 268.97 | 0.521 | 0.038 | 0.000 | 0.000 |
| G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.034 | 0.000 | 0.059 |
| G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.020 | 0.000 | 0.061 |
| G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.020 | 0.000 | 0.061 |
| G S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.356 | 0.019 | 0.000 | 0.045 |
| G S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.356 | 0.019 | 0.000 | 0.043 |
| M SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.356 | 0.045 | 0.000 | 0.046 |
| M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.048 | 0.000 | 0.064 |
| M SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.356 | 0.045 | 0.000 | 0.046 |
| M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.048 | 0.000 | 0.066 |
| M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.029 | 0.000 | 0.072 |
| M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.029 | 0.000 | 0.072 |
| M S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.356 | 0.027 | 0.000 | 0.047 |
| M S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.356 | 0.027 | 0.000 | 0.047 |
| T SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.355 | 0.060 | 0.000 | 0.051 |
| T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.064 | 0.000 | 0.068 |
| T SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.355 | 0.060 | 0.000 | 0.052 |
| T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.064 | 0.000 | 0.071 |
| T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.038 | 0.000 | 0.074 |
| T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.038 | 0.000 | 0.074 |
| T S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.355 | 0.036 | 0.000 | 0.052 |
| T S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.355 | 0.036 | 0.000 | 0.052 |
| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| G SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
| G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
| OFFICE | 4.75 | 4.75 | 268.97 | 0.502 | 0.000 | 0.000 | 0.000 |
| G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
| G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
| G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
| G S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
| G S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
| M SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
| M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
| M SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
| M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
| M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
| M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
| M S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
| M S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
| T SW APARTMENT | 2.40 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
| T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T SE APARTMENT | 2.40 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
| T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
| T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
| T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
| T S1 APARTMENT | 2.40 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
| T S2 APARTMENT | 2.40 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Mechanical Ventilation Parameters by Zone| AirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
| G SW APARTMENT | SPLIT GSW | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G NW APARTMENT | SPLIT GNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| OFFICE | SPLIT OFFICE | 4.75 | 4.75 | 268.97 | 88.25 | 0.0381 | 0.038 |
| G NE APARTMENT | SPLIT GNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G N1 APARTMENT | SPLIT GN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G N2 APARTMENT | SPLIT GN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G S1 APARTMENT | SPLIT GS1 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G S2 APARTMENT | SPLIT GS2 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| M SW APARTMENT | SPLIT MSW | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M NW APARTMENT | SPLIT MNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M SE APARTMENT | SPLIT MSE | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M NE APARTMENT | SPLIT MNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M N1 APARTMENT | SPLIT MN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M N2 APARTMENT | SPLIT MN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M S1 APARTMENT | SPLIT MS1 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M S2 APARTMENT | SPLIT MS2 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| T SW APARTMENT | SPLIT TSW | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T NW APARTMENT | SPLIT TNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T SE APARTMENT | SPLIT TSE | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T NE APARTMENT | SPLIT TNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T N1 APARTMENT | SPLIT TN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T N2 APARTMENT | SPLIT TN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T S1 APARTMENT | SPLIT TS1 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T S2 APARTMENT | SPLIT TS2 | 2.40 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| Total Facility | 68.17 | 82.25 | 8607.06 | 2823.98 | 0.8427 | 1.258 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| G SW APARTMENT | 818502.78 | 116953.71 | 935456.49 | 77244.92 | 1012701.41 | 818502.78 | 0.00 | 7496.33 | 1263.67 | 2615.00 |
| G NW APARTMENT | 818502.78 | 131336.26 | 949839.03 | 77244.92 | 1027083.95 | 818502.78 | 0.00 | 7309.19 | 1450.81 | 0.00 |
| OFFICE | 1161736.54 | 0.00 | 1161736.54 | 77244.92 | 1238981.46 | 1201711.97 | 500.00 | 8260.00 | 0.00 | 7010.00 |
| G NE APARTMENT | 818502.78 | 134959.26 | 953462.04 | 77244.92 | 1030706.96 | 818502.78 | 0.00 | 7281.96 | 1478.04 | 0.00 |
| G N1 APARTMENT | 818502.78 | 139854.51 | 958357.29 | 46592.17 | 1004949.46 | 818502.78 | 0.00 | 7227.27 | 1532.73 | 0.00 |
| G N2 APARTMENT | 818502.78 | 139958.57 | 958461.35 | 46592.17 | 1005053.52 | 818502.78 | 0.00 | 7226.46 | 1533.54 | 0.00 |
| G S1 APARTMENT | 818502.78 | 117050.80 | 935553.58 | 46592.17 | 982145.75 | 818502.78 | 0.00 | 7503.12 | 1256.88 | 2615.00 |
| G S2 APARTMENT | 818502.78 | 113274.36 | 931777.14 | 46592.17 | 978369.31 | 818502.78 | 0.00 | 7553.14 | 1206.86 | 2615.00 |
| M SW APARTMENT | 1637005.55 | 122022.45 | 1759028.01 | 111006.69 | 1870034.70 | 1637005.55 | 0.00 | 7581.92 | 1178.08 | 2615.00 |
| M NW APARTMENT | 1637005.55 | 146589.71 | 1783595.27 | 111006.69 | 1894601.96 | 1637005.55 | 0.00 | 7363.70 | 1396.30 | 0.00 |
| M SE APARTMENT | 1637005.55 | 118184.06 | 1755189.62 | 111006.69 | 1866196.31 | 1637005.55 | 0.00 | 7623.88 | 1136.12 | 2615.00 |
| M NE APARTMENT | 1637005.55 | 151574.36 | 1788579.92 | 111006.69 | 1899586.61 | 1637005.55 | 0.00 | 7329.27 | 1430.73 | 0.00 |
| M N1 APARTMENT | 1637005.55 | 165923.20 | 1802928.76 | 66956.42 | 1869885.17 | 1637005.55 | 0.00 | 7184.37 | 1575.63 | 0.00 |
| M N2 APARTMENT | 1637005.55 | 165818.40 | 1802823.95 | 66956.42 | 1869780.37 | 1637005.55 | 0.00 | 7185.46 | 1574.54 | 0.00 |
| M S1 APARTMENT | 1637005.55 | 123449.63 | 1760455.18 | 66956.42 | 1827411.60 | 1637005.55 | 0.00 | 7571.72 | 1188.28 | 2615.00 |
| M S2 APARTMENT | 1637005.55 | 123278.69 | 1760284.24 | 66956.42 | 1827240.66 | 1637005.55 | 0.00 | 7573.30 | 1186.70 | 2615.00 |
| T SW APARTMENT | 818502.78 | 139283.59 | 957786.36 | 146838.49 | 1104624.85 | 818502.78 | 0.00 | 7554.55 | 1205.45 | 2615.00 |
| T NW APARTMENT | 818502.78 | 157632.88 | 976135.65 | 146838.49 | 1122974.14 | 818502.78 | 0.00 | 7419.71 | 1340.29 | 0.00 |
| T SE APARTMENT | 818502.78 | 135394.52 | 953897.30 | 146838.49 | 1100735.78 | 818502.78 | 0.00 | 7591.92 | 1168.08 | 2615.00 |
| T NE APARTMENT | 818502.78 | 163317.03 | 981819.80 | 146838.49 | 1128658.29 | 818502.78 | 0.00 | 7388.72 | 1371.28 | 0.00 |
| T N1 APARTMENT | 818502.78 | 171860.68 | 990363.46 | 88569.25 | 1078932.71 | 818502.78 | 0.00 | 7308.57 | 1451.43 | 0.00 |
| T N2 APARTMENT | 818502.78 | 171655.89 | 990158.67 | 88569.25 | 1078727.91 | 818502.78 | 0.00 | 7310.90 | 1449.10 | 0.00 |
| T S1 APARTMENT | 818502.78 | 141139.79 | 959642.57 | 88569.25 | 1048211.82 | 818502.78 | 0.00 | 7549.24 | 1210.76 | 2615.00 |
| T S2 APARTMENT | 818502.78 | 140591.49 | 959094.26 | 88569.25 | 1047663.51 | 818502.78 | 0.00 | 7553.34 | 1206.66 | 2615.00 |
| Total Facility | 39631367.07 | 4347944.36 | 43979311.43 | 2860684.17 | 46839995.59 | 39671342.50 | 500.00 | 8718.08 | 1716.03 | 8760.00 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
| G SW APARTMENT | 0.0260 | 0.0032 | 0.0292 | 0.0023 | 0.0315 | 0.0260 | 0.00 | 5360.86 | 784.14 |
| G NW APARTMENT | 0.0260 | 0.0042 | 0.0301 | 0.0024 | 0.0326 | 0.0260 | 0.00 | 7309.19 | 1450.81 |
| OFFICE | 0.0381 | 0.0000 | 0.0381 | 0.0028 | 0.0409 | 0.0381 | 0.00 | 1750.00 | 0.00 |
| G NE APARTMENT | 0.0260 | 0.0043 | 0.0302 | 0.0024 | 0.0327 | 0.0260 | 0.00 | 7281.96 | 1478.04 |
| G N1 APARTMENT | 0.0260 | 0.0044 | 0.0304 | 0.0015 | 0.0319 | 0.0260 | 0.00 | 7227.27 | 1532.73 |
| G N2 APARTMENT | 0.0260 | 0.0044 | 0.0304 | 0.0015 | 0.0319 | 0.0260 | 0.00 | 7226.46 | 1533.54 |
| G S1 APARTMENT | 0.0260 | 0.0033 | 0.0292 | 0.0014 | 0.0306 | 0.0260 | 0.00 | 5356.88 | 788.12 |
| G S2 APARTMENT | 0.0260 | 0.0031 | 0.0291 | 0.0014 | 0.0305 | 0.0260 | 0.00 | 5395.00 | 750.00 |
| M SW APARTMENT | 0.0519 | 0.0033 | 0.0553 | 0.0033 | 0.0586 | 0.0519 | 0.00 | 5406.84 | 738.16 |
| M NW APARTMENT | 0.0519 | 0.0046 | 0.0566 | 0.0035 | 0.0601 | 0.0519 | 0.00 | 7363.70 | 1396.30 |
| M SE APARTMENT | 0.0519 | 0.0033 | 0.0552 | 0.0033 | 0.0586 | 0.0519 | 0.00 | 5408.32 | 736.68 |
| M NE APARTMENT | 0.0519 | 0.0048 | 0.0567 | 0.0035 | 0.0602 | 0.0519 | 0.00 | 7329.27 | 1430.73 |
| M N1 APARTMENT | 0.0519 | 0.0053 | 0.0572 | 0.0021 | 0.0593 | 0.0519 | 0.00 | 7184.37 | 1575.63 |
| M N2 APARTMENT | 0.0519 | 0.0053 | 0.0572 | 0.0021 | 0.0593 | 0.0519 | 0.00 | 7185.46 | 1574.54 |
| M S1 APARTMENT | 0.0519 | 0.0034 | 0.0554 | 0.0020 | 0.0574 | 0.0519 | 0.00 | 5388.44 | 756.56 |
| M S2 APARTMENT | 0.0519 | 0.0034 | 0.0554 | 0.0020 | 0.0574 | 0.0519 | 0.00 | 5387.89 | 757.11 |
| T SW APARTMENT | 0.0260 | 0.0037 | 0.0297 | 0.0044 | 0.0341 | 0.0260 | 0.00 | 5405.31 | 739.69 |
| T NW APARTMENT | 0.0260 | 0.0050 | 0.0310 | 0.0047 | 0.0356 | 0.0260 | 0.00 | 7419.71 | 1340.29 |
| T SE APARTMENT | 0.0260 | 0.0038 | 0.0297 | 0.0044 | 0.0341 | 0.0260 | 0.00 | 5395.05 | 749.95 |
| T NE APARTMENT | 0.0260 | 0.0052 | 0.0311 | 0.0047 | 0.0358 | 0.0260 | 0.00 | 7388.72 | 1371.28 |
| T N1 APARTMENT | 0.0260 | 0.0054 | 0.0314 | 0.0028 | 0.0342 | 0.0260 | 0.00 | 7308.57 | 1451.43 |
| T N2 APARTMENT | 0.0260 | 0.0054 | 0.0314 | 0.0028 | 0.0342 | 0.0260 | 0.00 | 7310.90 | 1449.10 |
| T S1 APARTMENT | 0.0260 | 0.0038 | 0.0298 | 0.0026 | 0.0324 | 0.0260 | 0.00 | 5391.79 | 753.21 |
| T S2 APARTMENT | 0.0260 | 0.0038 | 0.0298 | 0.0026 | 0.0324 | 0.0260 | 0.00 | 5391.93 | 753.07 |
| Total Facility | 1.2580 | 0.1303 | 1.3882 | 0.0885 | 1.4768 | 1.2580 | 500.00 | 8718.05 | 1716.03 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| SPLIT GSW | 0.00 | 116953.71 | 116953.71 | 818502.78 | 8049.26 | 44.63 | 666.11 | 479.52 |
| SPLIT GNW | 0.00 | 131336.26 | 131336.26 | 818502.78 | 8027.60 | 48.86 | 683.54 | 0.00 |
| SPLIT OFFICE | 1681742.10 | 0.00 | 1681742.10 | 1201711.97 | 481.33 | 5.33 | 8273.33 | 7009.83 |
| SPLIT GNE | 0.00 | 134959.26 | 134959.26 | 818502.78 | 7997.97 | 45.78 | 716.25 | 0.00 |
| SPLIT GN1 | 0.00 | 139854.51 | 139854.51 | 818502.78 | 7965.43 | 51.25 | 743.32 | 0.00 |
| SPLIT GN2 | 0.00 | 139958.57 | 139958.57 | 818502.78 | 7964.36 | 51.53 | 744.11 | 0.00 |
| SPLIT GS1 | 0.00 | 117050.80 | 117050.80 | 818502.78 | 8041.08 | 39.46 | 679.46 | 468.76 |
| SPLIT GS2 | 0.00 | 113274.36 | 113274.36 | 818502.78 | 8051.12 | 38.34 | 670.53 | 456.85 |
| SPLIT MSW | 0.00 | 122022.45 | 122022.45 | 1637005.55 | 8749.47 | 0.75 | 9.78 | 439.92 |
| SPLIT MNW | 0.00 | 146589.71 | 146589.71 | 1637005.55 | 8742.80 | 3.37 | 13.83 | 0.00 |
| SPLIT MSE | 0.00 | 118184.06 | 118184.06 | 1637005.55 | 8749.43 | 0.79 | 9.78 | 399.44 |
| SPLIT MNE | 0.00 | 151574.36 | 151574.36 | 1637005.55 | 8742.61 | 3.50 | 13.89 | 0.00 |
| SPLIT MN1 | 0.00 | 165923.20 | 165923.20 | 1637005.55 | 8742.64 | 3.64 | 13.72 | 0.00 |
| SPLIT MN2 | 0.00 | 165818.40 | 165818.40 | 1637005.55 | 8742.64 | 3.64 | 13.72 | 0.00 |
| SPLIT MS1 | 0.00 | 123449.63 | 123449.63 | 1637005.55 | 8749.33 | 0.83 | 9.83 | 431.73 |
| SPLIT MS2 | 0.00 | 123278.69 | 123278.69 | 1637005.55 | 8749.33 | 0.83 | 9.83 | 429.59 |
| SPLIT TSW | 0.00 | 139283.59 | 139283.59 | 818502.78 | 7858.40 | 26.48 | 875.12 | 465.76 |
| SPLIT TNW | 0.00 | 157632.88 | 157632.88 | 818502.78 | 7772.49 | 26.37 | 961.14 | 0.00 |
| SPLIT TSE | 0.00 | 135394.52 | 135394.52 | 818502.78 | 7874.44 | 23.80 | 861.77 | 418.12 |
| SPLIT TNE | 0.00 | 163317.03 | 163317.03 | 818502.78 | 7722.33 | 26.36 | 1011.32 | 0.00 |
| SPLIT TN1 | 0.00 | 171860.68 | 171860.68 | 818502.78 | 7675.29 | 26.44 | 1058.27 | 0.00 |
| SPLIT TN2 | 0.00 | 171655.89 | 171655.89 | 818502.78 | 7676.23 | 27.20 | 1056.56 | 0.00 |
| SPLIT TS1 | 0.00 | 141139.79 | 141139.79 | 818502.78 | 7843.51 | 26.32 | 890.16 | 457.55 |
| SPLIT TS2 | 0.00 | 140591.49 | 140591.49 | 818502.78 | 7847.19 | 25.58 | 887.23 | 453.60 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
| SPLIT GSW | 0.0000 | 0.0032 | 0.0032 | 0.0260 | 5710.25 | 30.41 | 404.35 |
| SPLIT GNW | 0.0000 | 0.0042 | 0.0042 | 0.0260 | 8027.60 | 48.86 | 683.54 |
| SPLIT OFFICE | 0.0552 | 0.0000 | 0.0552 | 0.0381 | 0.00 | 0.00 | 1750.00 |
| SPLIT GNE | 0.0000 | 0.0043 | 0.0043 | 0.0260 | 7997.97 | 45.78 | 716.25 |
| SPLIT GN1 | 0.0000 | 0.0044 | 0.0044 | 0.0260 | 7965.43 | 51.25 | 743.32 |
| SPLIT GN2 | 0.0000 | 0.0044 | 0.0044 | 0.0260 | 7964.36 | 51.53 | 744.11 |
| SPLIT GS1 | 0.0000 | 0.0033 | 0.0033 | 0.0260 | 5705.44 | 25.96 | 413.60 |
| SPLIT GS2 | 0.0000 | 0.0031 | 0.0031 | 0.0260 | 5713.21 | 25.23 | 406.56 |
| SPLIT MSW | 0.0000 | 0.0033 | 0.0033 | 0.0519 | 6144.08 | 0.08 | 0.83 |
| SPLIT MNW | 0.0000 | 0.0046 | 0.0046 | 0.0519 | 8742.80 | 3.37 | 13.83 |
| SPLIT MSE | 0.0000 | 0.0033 | 0.0033 | 0.0519 | 6144.04 | 0.12 | 0.83 |
| SPLIT MNE | 0.0000 | 0.0048 | 0.0048 | 0.0519 | 8742.61 | 3.50 | 13.89 |
| SPLIT MN1 | 0.0000 | 0.0053 | 0.0053 | 0.0519 | 8742.64 | 3.64 | 13.72 |
| SPLIT MN2 | 0.0000 | 0.0053 | 0.0053 | 0.0519 | 8742.64 | 3.64 | 13.72 |
| SPLIT MS1 | 0.0000 | 0.0034 | 0.0034 | 0.0519 | 6144.00 | 0.17 | 0.83 |
| SPLIT MS2 | 0.0000 | 0.0034 | 0.0034 | 0.0519 | 6144.00 | 0.17 | 0.83 |
| SPLIT TSW | 0.0000 | 0.0037 | 0.0037 | 0.0260 | 5608.87 | 17.10 | 519.03 |
| SPLIT TNW | 0.0000 | 0.0050 | 0.0050 | 0.0260 | 7772.49 | 26.37 | 961.14 |
| SPLIT TSE | 0.0000 | 0.0038 | 0.0038 | 0.0260 | 5601.41 | 15.75 | 527.84 |
| SPLIT TNE | 0.0000 | 0.0052 | 0.0052 | 0.0260 | 7722.33 | 26.36 | 1011.32 |
| SPLIT TN1 | 0.0000 | 0.0054 | 0.0054 | 0.0260 | 7675.29 | 26.44 | 1058.27 |
| SPLIT TN2 | 0.0000 | 0.0054 | 0.0054 | 0.0260 | 7676.23 | 27.20 | 1056.56 |
| SPLIT TS1 | 0.0000 | 0.0038 | 0.0038 | 0.0260 | 5596.35 | 15.42 | 533.23 |
| SPLIT TS2 | 0.0000 | 0.0038 | 0.0038 | 0.0260 | 5597.05 | 15.36 | 532.59 |
| No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
| SPLIT GSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT OFFICE | 8759.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MSE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TSE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
| SPLIT GSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT OFFICE | 0.0552 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MSE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TSE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Surfaces by Class| Total | Outdoors | |
| Wall | 126 | 42 |
| Floor | 27 | 9 |
| Roof | 27 | 9 |
| Internal Mass | 24 | 0 |
| Building Detached Shading | 0 | 0 |
| Fixed Detached Shading | 0 | 0 |
| Window | 39 | 39 |
| Door | 0 | 0 |
| Glass Door | 0 | 0 |
| Shading | 0 | 0 |
| Overhang | 0 | 0 |
| Fin | 0 | 0 |
| Tubular Daylighting Device Dome | 0 | 0 |
| Tubular Daylighting Device Diffuser | 0 | 0 |
| Count | |
| HVAC Air Loops | 24 |
| Conditioned Zones | 24 |
| Unconditioned Zones | 3 |
| Supply Plenums | 0 |
| Return Plenums | 0 |
| Count | |
| IDF Objects | 1588 |
| Defaulted Fields | 1666 |
| Fields with Defaults | 5801 |
| Autosized Fields | 648 |
| Autosizable Fields | 770 |
| Autocalculated Fields | 332 |
| Autocalculatable Fields | 509 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Annual and Peak Values - Electricity| Electricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| Electricity:Facility | 942.81 | 14290.02 | 04-FEB-04:00 | 57461.20 | 10-SEP-16:10 |
| Electricity:Building | 527.01 | 10157.12 | 01-JAN-03:10 | 25266.90 | 03-JAN-17:10 |
| Electricity:Zone:G SW APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| Electricity:SpaceType:GENERAL | 527.01 | 10157.12 | 01-JAN-03:10 | 25266.90 | 03-JAN-17:10 |
| InteriorLights:Electricity | 73.00 | 1491.31 | 01-JAN-00:10 | 4040.47 | 01-JAN-19:10 |
| InteriorLights:Electricity:Zone:G SW APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| InteriorLights:Electricity:SpaceType:GENERAL | 73.00 | 1491.31 | 01-JAN-00:10 | 4040.47 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity | 67.97 | 1461.31 | 01-JAN-00:10 | 3560.62 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G SW APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 67.97 | 1461.31 | 01-JAN-00:10 | 3560.62 | 01-JAN-19:10 |
| Electricity:Zone:G NW APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G NW APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G NW APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:OFFICE | 13.20 | 218.21 | 01-JAN-00:10 | 992.54 | 03-JAN-08:10 |
| InteriorLights:Electricity:Zone:OFFICE | 5.68 | 89.52 | 01-JAN-00:10 | 447.62 | 03-JAN-08:10 |
| LightsWired:InteriorLights:Electricity:Zone:OFFICE | 5.68 | 89.52 | 01-JAN-00:10 | 447.62 | 03-JAN-08:10 |
| Electricity:Zone:G NE APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G NE APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G NE APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:G N1 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G N1 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G N1 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:G N2 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G N2 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G N2 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:G S1 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G S1 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G S1 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:G S2 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G S2 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G S2 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:M SW APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M SW APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M SW APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:M NW APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M NW APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M NW APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:M SE APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M SE APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M SE APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:M NE APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M NE APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M NE APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:M N1 APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M N1 APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M N1 APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:M N2 APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M N2 APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M N2 APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:M S1 APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M S1 APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M S1 APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:M S2 APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M S2 APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M S2 APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:T SW APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T SW APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T SW APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:T NW APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T NW APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T NW APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:T SE APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T SE APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T SE APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:T NE APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T NE APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T NE APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:T N1 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T N1 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T N1 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:T N2 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T N2 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T N2 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:T S1 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T S1 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T S1 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:T S2 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T S2 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T S2 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:G CORRIDOR | 77.61 | 1911.10 | 01-JAN-00:10 | 4111.81 | 01-JAN-07:10 |
| InteriorLights:Electricity:Zone:G CORRIDOR | 9.71 | 307.95 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:G CORRIDOR | 9.71 | 307.95 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 |
| Electricity:Zone:M CORRIDOR | 19.42 | 615.89 | 01-JAN-00:10 | 615.89 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:M CORRIDOR | 19.42 | 615.89 | 01-JAN-00:10 | 615.89 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:M CORRIDOR | 19.42 | 615.89 | 01-JAN-00:10 | 615.89 | 01-JAN-00:10 |
| Electricity:Zone:T CORRIDOR | 9.71 | 307.95 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:T CORRIDOR | 9.71 | 307.95 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:T CORRIDOR | 9.71 | 307.95 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 |
| LightsPlugIn:InteriorLights:Electricity | 5.02 | 30.00 | 01-JAN-00:10 | 479.85 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G SW APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:SpaceType:GENERAL | 5.02 | 30.00 | 01-JAN-00:10 | 479.85 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G NW APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G NE APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G N1 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G N2 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G S1 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G S2 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M SW APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M NW APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M SE APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M NE APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M N1 APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M N2 APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M S1 APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M S2 APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T SW APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T NW APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T SE APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T NE APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T N1 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T N2 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T S1 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T S2 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| InteriorEquipment:Electricity | 454.01 | 8665.81 | 01-JAN-03:10 | 22246.15 | 03-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G CORRIDOR | 67.90 | 1603.15 | 01-JAN-00:10 | 3803.87 | 01-JAN-07:10 |
| InteriorEquipment:Electricity:SpaceType:GENERAL | 454.01 | 8665.81 | 01-JAN-03:10 | 22246.15 | 03-JAN-17:10 |
| ElevatorLift:InteriorEquipment:Electricity | 67.41 | 1600.00 | 01-JAN-00:10 | 3772.37 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity:Zone:G CORRIDOR | 67.41 | 1600.00 | 01-JAN-00:10 | 3772.37 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity:SpaceType:GENERAL | 67.41 | 1600.00 | 01-JAN-00:10 | 3772.37 | 01-JAN-07:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity | 0.49 | 3.15 | 01-JAN-00:10 | 31.50 | 01-JAN-07:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity:Zone:G CORRIDOR | 0.49 | 3.15 | 01-JAN-00:10 | 31.50 | 01-JAN-07:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity:SpaceType:GENERAL | 0.49 | 3.15 | 01-JAN-00:10 | 31.50 | 01-JAN-07:10 |
| InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity | 386.12 | 7062.66 | 01-JAN-03:10 | 18442.28 | 03-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 386.12 | 7062.66 | 01-JAN-03:10 | 18442.28 | 03-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:OFFICE | 7.52 | 128.69 | 01-JAN-00:10 | 544.92 | 03-JAN-08:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:OFFICE | 7.52 | 128.69 | 01-JAN-00:10 | 544.92 | 03-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| Fans:Electricity | 122.14 | 1449.45 | 10-MAR-12:30 | 8952.52 | 05-SEP-08:50 |
| Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityPurchased:Facility | 942.81 | 14290.02 | 04-FEB-04:00 | 57461.20 | 10-SEP-16:10 |
| ElectricityPurchased:Plant | 942.81 | 14290.02 | 04-FEB-04:00 | 57461.20 | 10-SEP-16:10 |
| Cogeneration:ElectricityPurchased | 942.81 | 14290.02 | 04-FEB-04:00 | 57461.20 | 10-SEP-16:10 |
| General:Cogeneration:ElectricityPurchased | 942.81 | 14290.02 | 04-FEB-04:00 | 57461.20 | 10-SEP-16:10 |
| ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityNet:Facility | 942.81 | 14290.02 | 04-FEB-04:00 | 57461.20 | 10-SEP-16:10 |
| ElectricityNet:Plant | 942.81 | 14290.02 | 04-FEB-04:00 | 57461.20 | 10-SEP-16:10 |
| Cogeneration:ElectricityNet | 942.81 | 14290.02 | 04-FEB-04:00 | 57461.20 | 10-SEP-16:10 |
| General:Cogeneration:ElectricityNet | 942.81 | 14290.02 | 04-FEB-04:00 | 57461.20 | 10-SEP-16:10 |
| Electricity:HVAC | 382.33 | 1496.04 | 10-MAR-12:30 | 37717.67 | 05-SEP-08:50 |
| HeatRecovery:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:HeatRecovery:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Fans:Electricity | 122.14 | 1449.45 | 10-MAR-12:30 | 8952.52 | 05-SEP-08:50 |
| Cooling:Electricity | 258.54 | 0.00 | 01-JAN-06:20 | 28765.14 | 05-SEP-08:50 |
| General:Cooling:Electricity | 258.54 | 0.00 | 01-JAN-06:20 | 28765.14 | 05-SEP-08:50 |
| Heating:Electricity | 1.64 | 0.00 | 01-JAN-00:10 | 5133.41 | 05-FEB-07:00 |
| General:Heating:Electricity | 1.64 | 0.00 | 01-JAN-00:10 | 5133.41 | 05-FEB-07:00 |
| ExteriorLights:Electricity | 33.02 | 0.00 | 01-JAN-07:30 | 2101.03 | 01-JAN-00:10 |
| General:ExteriorLights:Electricity | 33.02 | 0.00 | 01-JAN-07:30 | 2101.03 | 01-JAN-00:10 |
| Electricity:Plant | 0.46 | 14.49 | 01-JAN-00:10 | 14.49 | 01-JAN-06:10 |
| Pumps:Electricity | 0.46 | 14.49 | 01-JAN-00:10 | 14.49 | 01-JAN-06:10 |
| General:Pumps:Electricity | 0.46 | 14.49 | 01-JAN-00:10 | 14.49 | 01-JAN-06:10 |
| Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| NaturalGas:Facility | 354.15 | 0.00 | 01-JAN-02:40 | 24157.89 | 26-JAN-08:00 |
| NaturalGas:Plant | 354.15 | 0.00 | 01-JAN-02:40 | 24157.89 | 26-JAN-08:00 |
| WaterSystems:NaturalGas | 354.15 | 0.00 | 01-JAN-02:40 | 24157.89 | 26-JAN-08:00 |
| Water Heater:WaterSystems:NaturalGas | 354.15 | 0.00 | 01-JAN-02:40 | 24157.89 | 26-JAN-08:00 |
| Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| Water:Facility | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water:Plant | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| WaterSystems:Water | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| WaterUse:WaterSystems:Water | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| MainsWater:Facility | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| MainsWater:Plant | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| WaterSystems:MainsWater | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| WaterUse:WaterSystems:MainsWater | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 01-JAN-07:10 |
| Water Heater:WaterSystems:Water | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Water Heater:WaterSystems:MainsWater | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
| Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| EnergyTransfer:Facility | 2197.38 | 7857.38 | 13-NOV-14:10 | 205430.08 | 05-SEP-08:50 |
| EnergyTransfer:Building | 715.82 | 152.18 | 05-SEP-05:50 | 75745.55 | 01-DEC-14:50 |
| EnergyTransfer:Zone:G SW APARTMENT | 23.86 | 0.00 | 28-APR-21:00 | 2703.74 | 01-DEC-16:10 |
| Heating:EnergyTransfer | 6.39 | 0.00 | 01-JAN-00:10 | 8476.52 | 05-FEB-07:00 |
| Heating:EnergyTransfer:Zone:G SW APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 34.31 | 01-JUN-13:40 |
| General:Heating:EnergyTransfer | 6.39 | 0.00 | 01-JAN-00:10 | 8476.52 | 05-FEB-07:00 |
| General:Heating:EnergyTransfer:Zone:G SW APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 34.31 | 01-JUN-13:40 |
| Cooling:EnergyTransfer | 709.44 | 0.00 | 20-FEB-12:50 | 75587.23 | 01-DEC-14:50 |
| Cooling:EnergyTransfer:Zone:G SW APARTMENT | 23.85 | 0.00 | 01-JAN-12:00 | 2703.74 | 01-DEC-16:10 |
| General:Cooling:EnergyTransfer | 709.44 | 0.00 | 20-FEB-12:50 | 75587.23 | 01-DEC-14:50 |
| General:Cooling:EnergyTransfer:Zone:G SW APARTMENT | 23.85 | 0.00 | 01-JAN-12:00 | 2703.74 | 01-DEC-16:10 |
| EnergyTransfer:Zone:G NW APARTMENT | 19.74 | 0.01 | 12-AUG-06:00 | 2168.73 | 12-JUL-17:00 |
| Heating:EnergyTransfer:Zone:G NW APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 44.92 | 05-MAR-11:30 |
| General:Heating:EnergyTransfer:Zone:G NW APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 44.92 | 05-MAR-11:30 |
| Cooling:EnergyTransfer:Zone:G NW APARTMENT | 19.73 | 0.00 | 01-JAN-11:40 | 2164.94 | 12-JUL-17:00 |
| General:Cooling:EnergyTransfer:Zone:G NW APARTMENT | 19.73 | 0.00 | 01-JAN-11:40 | 2164.94 | 12-JUL-17:00 |
| EnergyTransfer:Zone:OFFICE | 22.73 | 0.01 | 19-FEB-20:20 | 4153.30 | 10-OCT-06:20 |
| Heating:EnergyTransfer:Zone:OFFICE | 3.58 | 0.00 | 01-JAN-00:10 | 651.75 | 02-AUG-17:40 |
| General:Heating:EnergyTransfer:Zone:OFFICE | 3.58 | 0.00 | 01-JAN-00:10 | 651.75 | 02-AUG-17:40 |
| Cooling:EnergyTransfer:Zone:OFFICE | 19.15 | 0.00 | 01-JAN-10:30 | 4153.30 | 10-OCT-06:20 |
| General:Cooling:EnergyTransfer:Zone:OFFICE | 19.15 | 0.00 | 01-JAN-10:30 | 4153.30 | 10-OCT-06:20 |
| EnergyTransfer:Zone:G NE APARTMENT | 19.86 | 0.00 | 28-APR-05:50 | 1964.03 | 15-OCT-10:20 |
| Heating:EnergyTransfer:Zone:G NE APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 44.21 | 05-MAR-11:30 |
| General:Heating:EnergyTransfer:Zone:G NE APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 44.21 | 05-MAR-11:30 |
| Cooling:EnergyTransfer:Zone:G NE APARTMENT | 19.85 | 0.00 | 01-JAN-12:00 | 1956.64 | 15-OCT-10:20 |
| General:Cooling:EnergyTransfer:Zone:G NE APARTMENT | 19.85 | 0.00 | 01-JAN-12:00 | 1956.64 | 15-OCT-10:20 |
| EnergyTransfer:Zone:G N1 APARTMENT | 17.62 | 0.01 | 06-JUN-06:50 | 1895.25 | 14-SEP-17:00 |
| Heating:EnergyTransfer:Zone:G N1 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 60.81 | 01-JUN-14:00 |
| General:Heating:EnergyTransfer:Zone:G N1 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 60.81 | 01-JUN-14:00 |
| Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 17.61 | 0.00 | 01-JAN-11:50 | 1888.00 | 14-SEP-17:00 |
| General:Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 17.61 | 0.00 | 01-JAN-11:50 | 1888.00 | 14-SEP-17:00 |
| EnergyTransfer:Zone:G N2 APARTMENT | 17.63 | 0.01 | 22-OCT-07:50 | 1899.12 | 14-SEP-17:00 |
| Heating:EnergyTransfer:Zone:G N2 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 60.73 | 01-JUN-14:00 |
| General:Heating:EnergyTransfer:Zone:G N2 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 60.73 | 01-JUN-14:00 |
| Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 17.62 | 0.00 | 01-JAN-11:50 | 1891.87 | 14-SEP-17:00 |
| General:Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 17.62 | 0.00 | 01-JAN-11:50 | 1891.87 | 14-SEP-17:00 |
| EnergyTransfer:Zone:G S1 APARTMENT | 22.35 | 0.00 | 29-MAY-05:50 | 2483.63 | 17-DEC-17:30 |
| Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 61.22 | 01-JUN-14:00 |
| General:Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 61.22 | 01-JUN-14:00 |
| Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 22.34 | 0.00 | 01-JAN-12:00 | 2483.63 | 17-DEC-17:30 |
| General:Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 22.34 | 0.00 | 01-JAN-12:00 | 2483.63 | 17-DEC-17:30 |
| EnergyTransfer:Zone:G S2 APARTMENT | 23.98 | 0.01 | 23-SEP-07:40 | 2608.22 | 17-DEC-14:10 |
| Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 44.37 | 01-JUN-14:20 |
| General:Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 44.37 | 01-JUN-14:20 |
| Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 23.98 | 0.00 | 01-JAN-12:00 | 2608.22 | 17-DEC-14:10 |
| General:Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 23.98 | 0.00 | 01-JAN-12:00 | 2608.22 | 17-DEC-14:10 |
| EnergyTransfer:Zone:M SW APARTMENT | 52.85 | 0.01 | 27-AUG-05:50 | 6436.99 | 01-DEC-16:10 |
| Heating:EnergyTransfer:Zone:M SW APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 66.08 | 01-JUN-13:40 |
| General:Heating:EnergyTransfer:Zone:M SW APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 66.08 | 01-JUN-13:40 |
| Cooling:EnergyTransfer:Zone:M SW APARTMENT | 52.84 | 0.00 | 17-JAN-11:50 | 6436.99 | 01-DEC-16:10 |
| General:Cooling:EnergyTransfer:Zone:M SW APARTMENT | 52.84 | 0.00 | 17-JAN-11:50 | 6436.99 | 01-DEC-16:10 |
| EnergyTransfer:Zone:M NW APARTMENT | 43.38 | 0.04 | 23-DEC-15:50 | 4959.18 | 12-JUL-18:10 |
| Heating:EnergyTransfer:Zone:M NW APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 70.12 | 08-DEC-12:00 |
| General:Heating:EnergyTransfer:Zone:M NW APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 70.12 | 08-DEC-12:00 |
| Cooling:EnergyTransfer:Zone:M NW APARTMENT | 43.37 | 0.00 | 01-JAN-11:40 | 4959.18 | 12-JUL-18:10 |
| General:Cooling:EnergyTransfer:Zone:M NW APARTMENT | 43.37 | 0.00 | 01-JAN-11:40 | 4959.18 | 12-JUL-18:10 |
| EnergyTransfer:Zone:M SE APARTMENT | 53.12 | 0.01 | 12-SEP-21:20 | 6074.61 | 02-DEC-13:10 |
| Heating:EnergyTransfer:Zone:M SE APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 63.58 | 01-JUN-13:40 |
| General:Heating:EnergyTransfer:Zone:M SE APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 63.58 | 01-JUN-13:40 |
| Cooling:EnergyTransfer:Zone:M SE APARTMENT | 53.12 | 0.00 | 17-JAN-11:50 | 6074.61 | 02-DEC-13:10 |
| General:Cooling:EnergyTransfer:Zone:M SE APARTMENT | 53.12 | 0.00 | 17-JAN-11:50 | 6074.61 | 02-DEC-13:10 |
| EnergyTransfer:Zone:M NE APARTMENT | 43.60 | 0.02 | 12-OCT-06:40 | 4436.40 | 23-APR-09:40 |
| Heating:EnergyTransfer:Zone:M NE APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 62.62 | 01-JUN-13:40 |
| General:Heating:EnergyTransfer:Zone:M NE APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 62.62 | 01-JUN-13:40 |
| Cooling:EnergyTransfer:Zone:M NE APARTMENT | 43.59 | 0.00 | 01-JAN-11:50 | 4428.60 | 21-APR-10:10 |
| General:Cooling:EnergyTransfer:Zone:M NE APARTMENT | 43.59 | 0.00 | 01-JAN-11:50 | 4428.60 | 21-APR-10:10 |
| EnergyTransfer:Zone:M N1 APARTMENT | 37.66 | 0.01 | 09-AUG-21:30 | 3956.88 | 14-SEP-17:00 |
| Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.02 | 0.00 | 01-JAN-00:10 | 121.90 | 01-JUN-14:00 |
| General:Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.02 | 0.00 | 01-JAN-00:10 | 121.90 | 01-JUN-14:00 |
| Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 37.64 | 0.00 | 01-JAN-11:40 | 3943.32 | 14-SEP-17:00 |
| General:Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 37.64 | 0.00 | 01-JAN-11:40 | 3943.32 | 14-SEP-17:00 |
| EnergyTransfer:Zone:M N2 APARTMENT | 37.68 | 0.01 | 21-APR-09:10 | 3957.59 | 14-SEP-17:00 |
| Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.02 | 0.00 | 01-JAN-00:10 | 121.73 | 01-JUN-14:00 |
| General:Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.02 | 0.00 | 01-JAN-00:10 | 121.73 | 01-JUN-14:00 |
| Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 37.66 | 0.00 | 01-JAN-11:40 | 3944.02 | 14-SEP-17:00 |
| General:Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 37.66 | 0.00 | 01-JAN-11:40 | 3944.02 | 14-SEP-17:00 |
| EnergyTransfer:Zone:M S1 APARTMENT | 48.09 | 0.05 | 03-MAY-06:40 | 5704.86 | 02-DEC-13:10 |
| Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 122.79 | 01-JUN-14:00 |
| General:Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 122.79 | 01-JUN-14:00 |
| Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 48.08 | 0.00 | 17-JAN-11:50 | 5704.86 | 02-DEC-13:10 |
| General:Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 48.08 | 0.00 | 17-JAN-11:50 | 5704.86 | 02-DEC-13:10 |
| EnergyTransfer:Zone:M S2 APARTMENT | 48.12 | 0.01 | 03-MAY-06:40 | 5723.02 | 02-DEC-13:10 |
| Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 122.62 | 01-JUN-14:00 |
| General:Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 122.62 | 01-JUN-14:00 |
| Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 48.11 | 0.00 | 17-JAN-11:50 | 5723.02 | 02-DEC-13:10 |
| General:Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 48.11 | 0.00 | 17-JAN-11:50 | 5723.02 | 02-DEC-13:10 |
| EnergyTransfer:Zone:T SW APARTMENT | 26.51 | 0.00 | 27-AUG-06:40 | 3933.05 | 01-DEC-16:10 |
| Heating:EnergyTransfer:Zone:T SW APARTMENT | 0.31 | 0.00 | 01-JAN-00:10 | 1276.83 | 05-FEB-07:00 |
| General:Heating:EnergyTransfer:Zone:T SW APARTMENT | 0.31 | 0.00 | 01-JAN-00:10 | 1276.83 | 05-FEB-07:00 |
| Cooling:EnergyTransfer:Zone:T SW APARTMENT | 26.20 | 0.00 | 04-JAN-02:50 | 3933.05 | 01-DEC-16:10 |
| General:Cooling:EnergyTransfer:Zone:T SW APARTMENT | 26.20 | 0.00 | 04-JAN-02:50 | 3933.05 | 01-DEC-16:10 |
| EnergyTransfer:Zone:T NW APARTMENT | 22.83 | 0.01 | 03-JAN-23:40 | 3540.89 | 12-JUL-17:00 |
| Heating:EnergyTransfer:Zone:T NW APARTMENT | 0.71 | 0.00 | 01-JAN-00:10 | 1445.36 | 05-FEB-07:00 |
| General:Heating:EnergyTransfer:Zone:T NW APARTMENT | 0.71 | 0.00 | 01-JAN-00:10 | 1445.36 | 05-FEB-07:00 |
| Cooling:EnergyTransfer:Zone:T NW APARTMENT | 22.11 | 0.00 | 01-JAN-11:30 | 3540.89 | 12-JUL-17:00 |
| General:Cooling:EnergyTransfer:Zone:T NW APARTMENT | 22.11 | 0.00 | 01-JAN-11:30 | 3540.89 | 12-JUL-17:00 |
| EnergyTransfer:Zone:T SE APARTMENT | 26.56 | 0.01 | 01-JUN-06:40 | 3722.77 | 18-NOV-12:50 |
| Heating:EnergyTransfer:Zone:T SE APARTMENT | 0.30 | 0.00 | 01-JAN-00:10 | 1291.52 | 05-FEB-07:00 |
| General:Heating:EnergyTransfer:Zone:T SE APARTMENT | 0.30 | 0.00 | 01-JAN-00:10 | 1291.52 | 05-FEB-07:00 |
| Cooling:EnergyTransfer:Zone:T SE APARTMENT | 26.26 | 0.00 | 04-JAN-02:50 | 3722.77 | 18-NOV-12:50 |
| General:Cooling:EnergyTransfer:Zone:T SE APARTMENT | 26.26 | 0.00 | 04-JAN-02:50 | 3722.77 | 18-NOV-12:50 |
| EnergyTransfer:Zone:T NE APARTMENT | 22.89 | 0.01 | 12-JUN-05:50 | 3024.56 | 12-JUL-17:00 |
| Heating:EnergyTransfer:Zone:T NE APARTMENT | 0.68 | 0.00 | 01-JAN-00:10 | 1460.08 | 05-FEB-07:00 |
| General:Heating:EnergyTransfer:Zone:T NE APARTMENT | 0.68 | 0.00 | 01-JAN-00:10 | 1460.08 | 05-FEB-07:00 |
| Cooling:EnergyTransfer:Zone:T NE APARTMENT | 22.21 | 0.00 | 01-JAN-12:40 | 3024.56 | 12-JUL-17:00 |
| General:Cooling:EnergyTransfer:Zone:T NE APARTMENT | 22.21 | 0.00 | 01-JAN-12:40 | 3024.56 | 12-JUL-17:00 |
| EnergyTransfer:Zone:T N1 APARTMENT | 19.14 | 0.01 | 28-MAR-09:50 | 2737.03 | 12-JUL-18:10 |
| Heating:EnergyTransfer:Zone:T N1 APARTMENT | 0.26 | 0.00 | 01-JAN-00:10 | 850.06 | 05-FEB-07:00 |
| General:Heating:EnergyTransfer:Zone:T N1 APARTMENT | 0.26 | 0.00 | 01-JAN-00:10 | 850.06 | 05-FEB-07:00 |
| Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 18.88 | 0.00 | 01-JAN-11:40 | 2737.03 | 12-JUL-18:10 |
| General:Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 18.88 | 0.00 | 01-JAN-11:40 | 2737.03 | 12-JUL-18:10 |
| EnergyTransfer:Zone:T N2 APARTMENT | 19.16 | 0.00 | 27-NOV-17:00 | 2712.28 | 12-JUL-18:10 |
| Heating:EnergyTransfer:Zone:T N2 APARTMENT | 0.27 | 0.00 | 01-JAN-00:10 | 850.94 | 05-FEB-07:00 |
| General:Heating:EnergyTransfer:Zone:T N2 APARTMENT | 0.27 | 0.00 | 01-JAN-00:10 | 850.94 | 05-FEB-07:00 |
| Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 18.89 | 0.00 | 01-JAN-11:50 | 2712.28 | 12-JUL-18:10 |
| General:Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 18.89 | 0.00 | 01-JAN-11:50 | 2712.28 | 12-JUL-18:10 |
| EnergyTransfer:Zone:T S1 APARTMENT | 23.23 | 0.02 | 02-NOV-06:00 | 3574.06 | 01-DEC-14:50 |
| Heating:EnergyTransfer:Zone:T S1 APARTMENT | 0.06 | 0.00 | 01-JAN-00:10 | 650.38 | 05-FEB-07:00 |
| General:Heating:EnergyTransfer:Zone:T S1 APARTMENT | 0.06 | 0.00 | 01-JAN-00:10 | 650.38 | 05-FEB-07:00 |
| Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 23.17 | 0.00 | 04-JAN-05:50 | 3574.06 | 01-DEC-14:50 |
| General:Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 23.17 | 0.00 | 04-JAN-05:50 | 3574.06 | 01-DEC-14:50 |
| EnergyTransfer:Zone:T S2 APARTMENT | 23.26 | 0.02 | 02-NOV-06:00 | 3579.01 | 01-DEC-14:50 |
| Heating:EnergyTransfer:Zone:T S2 APARTMENT | 0.06 | 0.00 | 01-JAN-00:10 | 651.34 | 05-FEB-07:00 |
| General:Heating:EnergyTransfer:Zone:T S2 APARTMENT | 0.06 | 0.00 | 01-JAN-00:10 | 651.34 | 05-FEB-07:00 |
| Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 23.19 | 0.00 | 04-JAN-05:50 | 3579.01 | 01-DEC-14:50 |
| General:Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 23.19 | 0.00 | 04-JAN-05:50 | 3579.01 | 01-DEC-14:50 |
| EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| PlantLoopHeatingDemand:Facility | 272.55 | 141.99 | 24-JUL-02:30 | 18771.69 | 23-JAN-07:30 |
| PlantLoopHeatingDemand:Plant | 272.55 | 141.99 | 24-JUL-02:30 | 18771.69 | 23-JAN-07:30 |
| WaterSystems:PlantLoopHeatingDemand | 272.55 | 141.99 | 24-JUL-02:30 | 18771.69 | 23-JAN-07:30 |
| General:WaterSystems:PlantLoopHeatingDemand | 272.55 | 141.99 | 24-JUL-02:30 | 18771.69 | 23-JAN-07:30 |
| EnergyTransfer:HVAC | 1209.02 | 87.44 | 18-OCT-19:30 | 137910.58 | 05-SEP-08:50 |
| HeatRecoveryForHeating:EnergyTransfer | 79.59 | 0.00 | 01-JAN-13:00 | 17809.92 | 05-FEB-07:00 |
| HeatRecoveryForCooling:EnergyTransfer | 126.63 | 0.00 | 01-JAN-00:10 | 16540.97 | 10-SEP-13:00 |
| CoolingCoils:EnergyTransfer | 999.26 | 0.00 | 01-JAN-06:20 | 134101.13 | 05-SEP-08:50 |
| HeatingCoils:EnergyTransfer | 3.54 | 0.00 | 01-JAN-00:10 | 9204.90 | 05-FEB-07:00 |
| EnergyTransfer:Plant | 272.54 | 141.99 | 24-JUL-02:30 | 18769.77 | 23-JAN-07:30 |
| WaterSystems:EnergyTransfer | 272.54 | 141.99 | 24-JUL-02:30 | 18769.77 | 23-JAN-07:30 |
| WaterUse:WaterSystems:EnergyTransfer | 272.54 | 141.99 | 24-JUL-02:30 | 18769.77 | 23-JAN-07:30 |
| Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Annual Building Sensible Heat Gain Components| HVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
| G SW APARTMENT | 0.966 | -1.000 | 0.000 | -23.810 | 0.000 | 0.000 | 3.514 | 0.918 | 12.213 | 9.889 | 0.000 | 0.160 | 1.355 | 0.000 | -3.004 | 0.000 | -1.201 | -0.000 |
| G NW APARTMENT | 0.966 | -0.937 | 0.000 | -19.745 | 0.000 | 0.000 | 3.595 | 0.918 | 12.213 | 6.152 | 0.000 | 0.160 | 0.906 | 0.000 | -3.034 | 0.000 | -1.192 | -0.000 |
| OFFICE | 0.000 | 0.000 | 3.581 | -19.146 | 0.000 | 0.000 | 2.005 | 5.679 | 7.520 | 9.512 | 0.000 | 0.085 | 0.000 | 0.000 | -3.609 | 0.000 | -0.488 | -5.138 |
| G NE APARTMENT | 0.965 | -0.938 | 0.000 | -19.872 | 0.000 | 0.000 | 3.598 | 0.918 | 12.213 | 6.150 | 0.000 | 0.160 | 0.956 | 0.000 | -2.920 | 0.000 | -1.229 | -0.000 |
| G N1 APARTMENT | 0.965 | -0.964 | 0.000 | -17.600 | 0.000 | 0.000 | 3.578 | 0.918 | 12.213 | 2.608 | 0.000 | 0.096 | 1.225 | 0.000 | -1.927 | 0.000 | -1.113 | -0.000 |
| G N2 APARTMENT | 0.965 | -0.964 | 0.000 | -17.609 | 0.000 | 0.000 | 3.578 | 0.918 | 12.213 | 2.607 | 0.000 | 0.096 | 1.235 | 0.000 | -1.927 | 0.000 | -1.114 | -0.000 |
| G S1 APARTMENT | 0.966 | -1.015 | 0.000 | -22.284 | 0.000 | 0.000 | 3.504 | 0.918 | 12.213 | 6.392 | 0.000 | 0.097 | 2.097 | 0.000 | -1.825 | 0.000 | -1.063 | -0.000 |
| G S2 APARTMENT | 0.965 | -1.018 | 0.000 | -23.919 | 0.000 | 0.000 | 3.502 | 0.918 | 12.213 | 6.375 | 0.000 | 0.097 | 3.752 | 0.000 | -1.838 | 0.000 | -1.047 | -0.000 |
| M SW APARTMENT | 1.932 | -2.029 | 0.000 | -52.727 | 0.000 | 0.000 | 7.010 | 1.837 | 24.426 | 19.666 | 0.000 | 0.458 | 8.308 | 0.000 | -6.069 | 0.000 | -2.811 | -0.000 |
| M NW APARTMENT | 1.929 | -1.920 | 0.000 | -43.360 | 0.000 | 0.000 | 7.157 | 1.837 | 24.426 | 12.222 | 0.000 | 0.457 | 6.375 | 0.000 | -6.199 | 0.000 | -2.924 | -0.000 |
| M SE APARTMENT | 1.931 | -2.035 | 0.000 | -53.002 | 0.000 | 0.000 | 7.012 | 1.837 | 24.426 | 19.772 | 0.000 | 0.457 | 8.368 | 0.000 | -5.956 | 0.000 | -2.810 | -0.000 |
| M NE APARTMENT | 1.927 | -1.922 | 0.000 | -43.583 | 0.000 | 0.000 | 7.165 | 1.837 | 24.426 | 12.209 | 0.000 | 0.457 | 6.493 | 0.000 | -5.961 | 0.000 | -3.048 | -0.000 |
| M N1 APARTMENT | 1.930 | -1.963 | 0.000 | -37.592 | 0.000 | 0.000 | 7.133 | 1.837 | 24.426 | 5.200 | 0.000 | 0.276 | 5.453 | 0.000 | -3.929 | 0.000 | -2.771 | -0.000 |
| M N2 APARTMENT | 1.930 | -1.963 | 0.000 | -37.612 | 0.000 | 0.000 | 7.133 | 1.837 | 24.426 | 5.199 | 0.000 | 0.276 | 5.474 | 0.000 | -3.928 | 0.000 | -2.771 | -0.000 |
| M S1 APARTMENT | 1.932 | -2.049 | 0.000 | -47.948 | 0.000 | 0.000 | 6.998 | 1.837 | 24.426 | 12.734 | 0.000 | 0.276 | 7.858 | 0.000 | -3.669 | 0.000 | -2.395 | -0.000 |
| M S2 APARTMENT | 1.932 | -2.049 | 0.000 | -47.976 | 0.000 | 0.000 | 6.998 | 1.837 | 24.426 | 12.732 | 0.000 | 0.276 | 7.886 | 0.000 | -3.668 | 0.000 | -2.393 | -0.000 |
| T SW APARTMENT | 0.967 | -0.931 | 0.440 | -26.369 | 0.000 | 0.000 | 3.562 | 0.918 | 12.213 | 9.735 | 0.000 | 0.299 | 3.541 | 0.000 | -2.814 | 0.000 | -1.560 | -0.000 |
| T NW APARTMENT | 0.966 | -0.853 | 0.950 | -22.461 | 0.000 | 0.000 | 3.644 | 0.918 | 12.213 | 6.051 | 0.000 | 0.299 | 2.608 | 0.000 | -2.824 | 0.000 | -1.511 | -0.000 |
| T SE APARTMENT | 0.966 | -0.938 | 0.427 | -26.421 | 0.000 | 0.000 | 3.565 | 0.918 | 12.213 | 9.782 | 0.000 | 0.299 | 3.536 | 0.000 | -2.760 | 0.000 | -1.588 | -0.000 |
| T NE APARTMENT | 0.964 | -0.852 | 0.917 | -22.558 | 0.000 | 0.000 | 3.653 | 0.918 | 12.213 | 6.059 | 0.000 | 0.299 | 2.697 | 0.000 | -2.716 | 0.000 | -1.595 | -0.000 |
| T N1 APARTMENT | 0.966 | -0.864 | 0.424 | -19.138 | 0.000 | 0.000 | 3.638 | 0.918 | 12.213 | 2.573 | 0.000 | 0.180 | 2.226 | 0.000 | -1.785 | 0.000 | -1.351 | -0.000 |
| T N2 APARTMENT | 0.966 | -0.864 | 0.426 | -19.151 | 0.000 | 0.000 | 3.639 | 0.918 | 12.213 | 2.571 | 0.000 | 0.180 | 2.238 | 0.000 | -1.783 | 0.000 | -1.352 | -0.000 |
| T S1 APARTMENT | 0.966 | -0.959 | 0.122 | -23.234 | 0.000 | 0.000 | 3.544 | 0.918 | 12.213 | 6.314 | 0.000 | 0.181 | 2.995 | 0.000 | -1.728 | 0.000 | -1.332 | -0.000 |
| T S2 APARTMENT | 0.966 | -0.959 | 0.123 | -23.257 | 0.000 | 0.000 | 3.544 | 0.918 | 12.213 | 6.312 | 0.000 | 0.181 | 3.015 | 0.000 | -1.727 | 0.000 | -1.329 | -0.000 |
| T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.452 | 9.711 | 0.000 | 0.823 | 0.000 | 0.024 | 0.000 | 0.000 | -0.318 | 0.000 | -0.141 | -15.551 |
| G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.036 | 9.711 | 3.395 | 2.394 | 0.000 | 1.576 | 0.000 | 0.000 | -1.027 | 0.000 | -11.979 | -9.105 |
| M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 10.576 | 19.423 | 0.000 | 1.639 | 0.000 | 0.041 | 0.000 | 0.000 | -0.687 | 0.000 | -0.239 | -30.753 |
| Total Facility | 29.929 | -29.987 | 7.409 | -710.374 | 0.000 | 0.000 | 133.332 | 72.996 | 389.511 | 203.671 | 0.000 | 7.441 | 90.600 | 0.000 | -79.631 | 0.000 | -54.347 | -60.551 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| G SW APARTMENT | 17-DEC-17:01 | 0.00 | -90.13 | 0.00 | -5387.34 | 0.00 | 0.00 | 135.66 | 54.82 | 588.62 | 252.74 | 0.00 | 0.00 | 4498.59 | 0.00 | -0.00 | 0.00 | -52.95 | 0.00 |
| G NW APARTMENT | 17-DEC-17:32 | 0.00 | -90.24 | 0.00 | -4963.34 | 0.00 | 0.00 | 75.70 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 4769.73 | 0.00 | -382.71 | 0.00 | -52.59 | 0.00 |
| OFFICE | 03-JAN-07:01 | 0.00 | 0.00 | 0.00 | -6680.26 | 0.00 | 0.00 | 0.00 | 89.52 | 194.98 | 0.00 | 0.00 | 0.00 | 7138.97 | 0.00 | -657.90 | 0.00 | -85.32 | 0.00 |
| G NE APARTMENT | 30-NOV-22:22 | 0.00 | -63.54 | 0.00 | -4708.38 | 0.00 | 0.00 | 151.55 | 32.89 | 417.92 | 0.00 | 0.00 | 0.00 | 4504.55 | 0.00 | -314.19 | 0.00 | -20.81 | 0.00 |
| G N1 APARTMENT | 17-DEC-17:32 | 0.00 | -91.76 | 0.00 | -4226.95 | 0.00 | 0.00 | 77.40 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 3855.50 | 0.00 | -226.31 | 0.00 | -31.32 | 0.00 |
| G N2 APARTMENT | 17-DEC-17:32 | 0.00 | -91.69 | 0.00 | -4221.28 | 0.00 | 0.00 | 77.46 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 3849.51 | 0.00 | -226.15 | 0.00 | -31.29 | 0.00 |
| G S1 APARTMENT | 17-DEC-17:22 | 0.00 | -89.43 | 0.00 | -4603.46 | 0.00 | 0.00 | 145.07 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 4072.38 | 0.00 | -136.55 | 0.00 | -31.45 | 0.00 |
| G S2 APARTMENT | 17-DEC-17:01 | 0.00 | -91.31 | 0.00 | -4738.74 | 0.00 | 0.00 | 136.66 | 54.82 | 588.62 | 59.39 | 0.00 | 0.00 | 4022.44 | 0.00 | -0.00 | 0.00 | -31.89 | 0.00 |
| M SW APARTMENT | 17-DEC-17:01 | 0.00 | -181.98 | 0.00 | -11744.81 | 0.00 | 0.00 | 266.55 | 109.64 | 1177.25 | 484.24 | 0.00 | 0.00 | 10043.72 | 0.00 | -0.00 | 0.00 | -154.61 | 0.00 |
| M NW APARTMENT | 16-APR-20:42 | 0.00 | -140.69 | 0.00 | -10943.69 | 0.00 | 0.00 | 295.55 | 120.61 | 1000.66 | 0.00 | 0.00 | 0.00 | 10404.73 | 0.00 | -704.59 | 0.00 | -32.60 | 0.00 |
| M SE APARTMENT | 17-DEC-13:42 | 0.00 | -74.77 | 0.00 | -10857.92 | 0.00 | 0.00 | 128.64 | 21.93 | 776.98 | 2445.53 | 0.00 | 0.00 | 7686.37 | 0.00 | -0.00 | 0.00 | -126.75 | 0.00 |
| M NE APARTMENT | 16-APR-20:42 | 0.00 | -143.80 | 0.00 | -10231.52 | 0.00 | 0.00 | 293.09 | 120.61 | 1000.66 | 0.00 | 0.00 | 0.00 | 9690.32 | 0.00 | -696.40 | 0.00 | -32.97 | 0.00 |
| M N1 APARTMENT | 16-APR-20:42 | 0.00 | -148.53 | 0.00 | -9301.90 | 0.00 | 0.00 | 291.87 | 120.61 | 1000.66 | 0.00 | 0.00 | 0.00 | 8475.33 | 0.00 | -417.93 | 0.00 | -20.10 | 0.00 |
| M N2 APARTMENT | 16-APR-20:42 | 0.00 | -148.37 | 0.00 | -9287.03 | 0.00 | 0.00 | 292.07 | 120.61 | 1000.66 | 0.00 | 0.00 | 0.00 | 8459.82 | 0.00 | -417.68 | 0.00 | -20.08 | 0.00 |
| M S1 APARTMENT | 17-DEC-17:01 | 0.00 | -180.80 | 0.00 | -10087.17 | 0.00 | 0.00 | 273.65 | 109.64 | 1177.25 | 114.29 | 0.00 | 0.00 | 8684.70 | 0.00 | -0.00 | 0.00 | -91.56 | 0.00 |
| M S2 APARTMENT | 17-DEC-17:01 | 0.00 | -180.74 | 0.00 | -10074.30 | 0.00 | 0.00 | 273.76 | 109.64 | 1177.25 | 114.45 | 0.00 | 0.00 | 8671.47 | 0.00 | -0.00 | 0.00 | -91.53 | 0.00 |
| T SW APARTMENT | 17-DEC-17:01 | 0.00 | -96.66 | 0.00 | -6450.60 | 0.00 | 0.00 | 123.96 | 54.82 | 588.62 | 211.31 | 0.00 | 0.00 | 5676.65 | 0.00 | -0.00 | 0.00 | -108.10 | 0.00 |
| T NW APARTMENT | 16-APR-16:32 | 0.00 | -35.99 | 0.00 | -6172.92 | 0.00 | 0.00 | 62.64 | 54.82 | 588.62 | 810.65 | 0.00 | 0.00 | 4760.53 | 0.00 | -0.00 | 0.00 | -68.36 | 0.00 |
| T SE APARTMENT | 17-DEC-17:01 | 0.00 | -92.72 | 0.00 | -5850.02 | 0.00 | 0.00 | 131.02 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 5366.44 | 0.00 | -94.18 | 0.00 | -103.99 | 0.00 |
| T NE APARTMENT | 16-APR-16:32 | 0.00 | -30.27 | 0.00 | -5589.08 | 0.00 | 0.00 | 67.51 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 4992.68 | 0.00 | -22.14 | 0.00 | -62.14 | 0.00 |
| T N1 APARTMENT | 16-APR-16:32 | 0.00 | -29.65 | 0.00 | -5206.93 | 0.00 | 0.00 | 69.25 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 4569.11 | 0.00 | -8.91 | 0.00 | -36.31 | 0.00 |
| T N2 APARTMENT | 16-APR-16:32 | 0.00 | -29.81 | 0.00 | -5189.76 | 0.00 | 0.00 | 69.16 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 4552.45 | 0.00 | -9.09 | 0.00 | -36.39 | 0.00 |
| T S1 APARTMENT | 17-DEC-17:01 | 0.00 | -95.57 | 0.00 | -5515.21 | 0.00 | 0.00 | 128.83 | 54.82 | 588.62 | 42.53 | 0.00 | 0.00 | 4859.72 | 0.00 | -0.00 | 0.00 | -63.74 | 0.00 |
| T S2 APARTMENT | 17-DEC-17:01 | 0.00 | -95.47 | 0.00 | -5495.55 | 0.00 | 0.00 | 129.02 | 54.82 | 588.62 | 42.83 | 0.00 | 0.00 | 4839.40 | 0.00 | -0.00 | 0.00 | -63.68 | 0.00 |
| T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 16-APR-20:42 | 0.00 | -2195.43 | 0.00 | -158177.81 | 0.00 | 0.00 | 5542.98 | 3190.75 | 15719.84 | 0.00 | 0.00 | 0.00 | 146360.67 | 0.00 | -9052.56 | 0.00 | -1388.44 | 0.00 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| G SW APARTMENT | 24-APR-11:57 | 62.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.96 | 406.15 | 595.01 | 0.00 | 3.19 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1077.87 |
| G NW APARTMENT | 24-APR-11:57 | 63.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.58 | 10.96 | 406.15 | 477.11 | 0.00 | 3.20 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -997.17 |
| OFFICE | 06-FEB-07:01 | 0.00 | 0.00 | 3685.63 | 0.00 | 0.00 | 0.00 | 0.00 | 89.52 | 194.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -485.95 | 0.00 | -28.76 | -3455.42 |
| G NE APARTMENT | 01-JUN-14:07 | 86.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.27 | 19.19 | 400.26 | 465.14 | 0.00 | 5.80 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1013.40 |
| G N1 APARTMENT | 01-JUN-14:07 | 89.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.32 | 19.19 | 400.26 | 282.65 | 0.00 | 3.54 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -831.43 |
| G N2 APARTMENT | 01-JUN-14:07 | 89.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.30 | 19.19 | 400.26 | 282.55 | 0.00 | 3.55 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -831.41 |
| G S1 APARTMENT | 01-JUN-14:20 | 89.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.19 | 400.26 | 318.03 | 0.00 | 3.90 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -830.52 |
| G S2 APARTMENT | 01-JUN-14:20 | 88.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.19 | 400.26 | 317.04 | 0.00 | 3.89 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -829.12 |
| M SW APARTMENT | 24-APR-11:57 | 120.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.93 | 812.30 | 1168.69 | 0.00 | 8.91 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -2131.89 |
| M NW APARTMENT | 24-APR-11:57 | 123.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.54 | 21.93 | 812.30 | 931.73 | 0.00 | 9.05 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1971.44 |
| M SE APARTMENT | 24-APR-11:57 | 123.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.93 | 812.30 | 1222.94 | 0.00 | 9.04 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -2189.47 |
| M NE APARTMENT | 24-APR-11:57 | 126.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.53 | 21.93 | 812.30 | 985.93 | 0.00 | 9.10 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -2027.84 |
| M N1 APARTMENT | 01-JUN-14:07 | 174.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.72 | 38.38 | 800.53 | 561.28 | 0.00 | 10.03 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1657.02 |
| M N2 APARTMENT | 01-JUN-14:07 | 174.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.68 | 38.38 | 800.53 | 561.05 | 0.00 | 10.03 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1656.99 |
| M S1 APARTMENT | 24-APR-11:57 | 124.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.93 | 812.30 | 804.93 | 0.00 | 5.42 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1769.23 |
| M S2 APARTMENT | 24-APR-11:57 | 124.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.93 | 812.30 | 804.84 | 0.00 | 5.42 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1769.14 |
| T SW APARTMENT | 05-FEB-07:00 | -228.61 | 0.00 | 1505.44 | 0.00 | 0.00 | 0.00 | 194.99 | 38.37 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -659.10 | 0.00 | -234.18 | -934.76 |
| T NW APARTMENT | 05-FEB-07:00 | -228.60 | 0.00 | 1673.95 | 0.00 | 0.00 | 0.00 | 194.99 | 38.37 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -667.53 | 0.00 | -234.18 | -1094.85 |
| T SE APARTMENT | 05-FEB-07:00 | -228.61 | 0.00 | 1520.13 | 0.00 | 0.00 | 0.00 | 194.99 | 38.37 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -667.47 | 0.00 | -234.18 | -941.08 |
| T NE APARTMENT | 05-FEB-07:00 | -228.60 | 0.00 | 1688.67 | 0.00 | 0.00 | 0.00 | 194.99 | 38.37 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -675.84 | 0.00 | -234.18 | -1101.27 |
| T N1 APARTMENT | 05-FEB-07:00 | -228.67 | 0.00 | 1078.73 | 0.00 | 0.00 | 0.00 | 194.99 | 38.37 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -414.43 | 0.00 | -141.25 | -845.60 |
| T N2 APARTMENT | 05-FEB-07:00 | -228.67 | 0.00 | 1079.61 | 0.00 | 0.00 | 0.00 | 194.99 | 38.37 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -414.41 | 0.00 | -141.25 | -846.49 |
| T S1 APARTMENT | 05-FEB-07:00 | -228.69 | 0.00 | 879.07 | 0.00 | 0.00 | 0.00 | 194.99 | 38.37 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -405.06 | 0.00 | -141.25 | -655.28 |
| T S2 APARTMENT | 05-FEB-07:00 | -228.69 | 0.00 | 880.02 | 0.00 | 0.00 | 0.00 | 194.99 | 38.37 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -405.04 | 0.00 | -141.25 | -656.25 |
| T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 05-FEB-07:00 | -8018.06 | 669.32 | 10305.63 | -669.32 | 0.00 | 0.00 | 7038.49 | 2510.88 | 10105.59 | 0.00 | 0.00 | 0.00 | 4112.38 | 0.00 | -18833.08 | 0.00 | -7221.84 | 0.00 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
System Ventilation Requirements for Cooling| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| SPLIT GSW | 0.3181 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3181 | 0.0816 | 1.0000 | Not calculated | 0.0260 | 0.0816 | ||
| SPLIT GNW | 0.3025 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3025 | 0.0858 | 1.0000 | Not calculated | 0.0260 | 0.0858 | ||
| SPLIT OFFICE | 0.3681 | 0.0000 | 4.7495 | 1.0000 | Calculated from schedules | 0.0381 | 0.3681 | 0.1035 | 1.0000 | Not calculated | 0.0381 | 0.1035 | ||
| SPLIT GNE | 0.2808 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2808 | 0.0924 | 1.0000 | Not calculated | 0.0260 | 0.0924 | ||
| SPLIT GN1 | 0.2460 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2460 | 0.1055 | 1.0000 | Not calculated | 0.0260 | 0.1055 | ||
| SPLIT GN2 | 0.2456 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2456 | 0.1057 | 1.0000 | Not calculated | 0.0260 | 0.1057 | ||
| SPLIT GS1 | 0.2662 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2662 | 0.0975 | 1.0000 | Not calculated | 0.0260 | 0.0975 | ||
| SPLIT GS2 | 0.2691 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2691 | 0.0964 | 1.0000 | Not calculated | 0.0260 | 0.0964 | ||
| SPLIT MSW | 0.7050 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7050 | 0.0736 | 1.0000 | Not calculated | 0.0519 | 0.0736 | ||
| SPLIT MNW | 0.6715 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6715 | 0.0773 | 1.0000 | Not calculated | 0.0519 | 0.0773 | ||
| SPLIT MSE | 0.6469 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6469 | 0.0802 | 1.0000 | Not calculated | 0.0519 | 0.0802 | ||
| SPLIT MNE | 0.6140 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6140 | 0.0845 | 1.0000 | Not calculated | 0.0519 | 0.0845 | ||
| SPLIT MN1 | 0.5464 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.5464 | 0.0950 | 1.0000 | Not calculated | 0.0519 | 0.0950 | ||
| SPLIT MN2 | 0.5454 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.5454 | 0.0952 | 1.0000 | Not calculated | 0.0519 | 0.0952 | ||
| SPLIT MS1 | 0.5824 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.5824 | 0.0891 | 1.0000 | Not calculated | 0.0519 | 0.0891 | ||
| SPLIT MS2 | 0.5815 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.5815 | 0.0893 | 1.0000 | Not calculated | 0.0519 | 0.0893 | ||
| SPLIT TSW | 0.3921 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3921 | 0.0662 | 1.0000 | Not calculated | 0.0260 | 0.0662 | ||
| SPLIT TNW | 0.3796 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3796 | 0.0684 | 1.0000 | Not calculated | 0.0260 | 0.0684 | ||
| SPLIT TSE | 0.3489 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3489 | 0.0744 | 1.0000 | Not calculated | 0.0260 | 0.0744 | ||
| SPLIT TNE | 0.3363 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3363 | 0.0772 | 1.0000 | Not calculated | 0.0260 | 0.0772 | ||
| SPLIT TN1 | 0.3123 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3123 | 0.0831 | 1.0000 | Not calculated | 0.0260 | 0.0831 | ||
| SPLIT TN2 | 0.3109 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3109 | 0.0835 | 1.0000 | Not calculated | 0.0260 | 0.0835 | ||
| SPLIT TS1 | 0.3259 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3259 | 0.0796 | 1.0000 | Not calculated | 0.0260 | 0.0796 | ||
| SPLIT TS2 | 0.3245 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3245 | 0.0800 | 1.0000 | Not calculated | 0.0260 | 0.0800 |
| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| SPLIT GSW | 0.3181 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3181 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0816 | ||
| SPLIT GNW | 0.3025 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3025 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0858 | ||
| SPLIT OFFICE | 0.3681 | 0.0000 | 4.7495 | 1.0000 | Calculated from schedules | 0.0381 | 0.3681 | 1.0000 | 1.0000 | Not calculated | 0.0381 | 0.1035 | ||
| SPLIT GNE | 0.2808 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2808 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0924 | ||
| SPLIT GN1 | 0.2460 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2460 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.1055 | ||
| SPLIT GN2 | 0.2456 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2456 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.1057 | ||
| SPLIT GS1 | 0.2662 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2662 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0975 | ||
| SPLIT GS2 | 0.2691 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.2691 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0964 | ||
| SPLIT MSW | 0.7050 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7050 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0736 | ||
| SPLIT MNW | 0.6715 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6715 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0773 | ||
| SPLIT MSE | 0.6469 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6469 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0802 | ||
| SPLIT MNE | 0.6140 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6140 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0845 | ||
| SPLIT MN1 | 0.5464 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.5464 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0950 | ||
| SPLIT MN2 | 0.5454 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.5454 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0952 | ||
| SPLIT MS1 | 0.5824 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.5824 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0891 | ||
| SPLIT MS2 | 0.5815 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.5815 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0893 | ||
| SPLIT TSW | 0.3921 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3921 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0662 | ||
| SPLIT TNW | 0.3796 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3796 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0684 | ||
| SPLIT TSE | 0.3489 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3489 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0744 | ||
| SPLIT TNE | 0.3363 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3363 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0772 | ||
| SPLIT TN1 | 0.3123 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3123 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0831 | ||
| SPLIT TN2 | 0.3109 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3109 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0835 | ||
| SPLIT TS1 | 0.3259 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3259 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0796 | ||
| SPLIT TS2 | 0.3245 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3245 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0800 |
| AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| G SW APARTMENT | SPLIT GSW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G NW APARTMENT | SPLIT GNW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| OFFICE | SPLIT OFFICE | 0.000000 | 4.7495 | 0.000432 | 88.25 | 0.0381 | 1.0000 | 0.0381 | 1.000 | 0.0381 |
| G NE APARTMENT | SPLIT GNE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G N1 APARTMENT | SPLIT GN1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G N2 APARTMENT | SPLIT GN2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G S1 APARTMENT | SPLIT GS1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G S2 APARTMENT | SPLIT GS2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| M SW APARTMENT | SPLIT MSW | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M NW APARTMENT | SPLIT MNW | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M SE APARTMENT | SPLIT MSE | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M NE APARTMENT | SPLIT MNE | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M N1 APARTMENT | SPLIT MN1 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M N2 APARTMENT | SPLIT MN2 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M S1 APARTMENT | SPLIT MS1 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M S2 APARTMENT | SPLIT MS2 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| T SW APARTMENT | SPLIT TSW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T NW APARTMENT | SPLIT TNW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T SE APARTMENT | SPLIT TSE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T NE APARTMENT | SPLIT TNE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T N1 APARTMENT | SPLIT TN1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T N2 APARTMENT | SPLIT TN2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T S1 APARTMENT | SPLIT TS1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T S2 APARTMENT | SPLIT TS2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| SPLIT GSW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GNW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT OFFICE | 0.000000 | 4.75 | 0.000432 | 88.2493 | 0.0381 | 0.0381 | 0.0381 |
| SPLIT GNE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GN1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GN2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GS1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GS2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT MSW | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MNW | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MSE | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MNE | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MN1 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MN2 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MS1 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MS2 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT TSW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TNW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TSE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TNE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TN1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TN2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TS1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TS2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| G SW APARTMENT | SPLIT GSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3181 | 0.3181 | 0.3181 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NW APARTMENT | SPLIT GNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3025 | 0.3025 | 0.3025 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| OFFICE | SPLIT OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3681 | 0.3681 | 0.3681 | No | 0.0381 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NE APARTMENT | SPLIT GNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2808 | 0.2808 | 0.2808 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N1 APARTMENT | SPLIT GN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2460 | 0.2460 | 0.2460 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N2 APARTMENT | SPLIT GN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2456 | 0.2456 | 0.2456 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S1 APARTMENT | SPLIT GS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2662 | 0.2662 | 0.2662 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S2 APARTMENT | SPLIT GS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2691 | 0.2691 | 0.2691 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SW APARTMENT | SPLIT MSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7050 | 0.7050 | 0.7050 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NW APARTMENT | SPLIT MNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6715 | 0.6715 | 0.6715 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SE APARTMENT | SPLIT MSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6469 | 0.6469 | 0.6469 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NE APARTMENT | SPLIT MNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6140 | 0.6140 | 0.6140 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N1 APARTMENT | SPLIT MN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5464 | 0.5464 | 0.5464 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N2 APARTMENT | SPLIT MN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5454 | 0.5454 | 0.5454 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S1 APARTMENT | SPLIT MS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5824 | 0.5824 | 0.5824 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S2 APARTMENT | SPLIT MS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5815 | 0.5815 | 0.5815 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SW APARTMENT | SPLIT TSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3921 | 0.3921 | 0.3921 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NW APARTMENT | SPLIT TNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3796 | 0.3796 | 0.3796 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SE APARTMENT | SPLIT TSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3489 | 0.3489 | 0.3489 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NE APARTMENT | SPLIT TNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3363 | 0.3363 | 0.3363 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N1 APARTMENT | SPLIT TN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3123 | 0.3123 | 0.3123 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N2 APARTMENT | SPLIT TN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3109 | 0.3109 | 0.3109 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S1 APARTMENT | SPLIT TS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3259 | 0.3259 | 0.3259 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S2 APARTMENT | SPLIT TS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3245 | 0.3245 | 0.3245 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| SPLIT GSW | 0.3181 | 0.3181 | 0.3181 | 0.3181 | 0.0260 | 1.0000 |
| SPLIT GNW | 0.3025 | 0.3025 | 0.3025 | 0.3025 | 0.0260 | 1.0000 |
| SPLIT OFFICE | 0.3681 | 0.3681 | 0.3681 | 0.3681 | 0.0381 | 1.0000 |
| SPLIT GNE | 0.2808 | 0.2808 | 0.2808 | 0.2808 | 0.0260 | 1.0000 |
| SPLIT GN1 | 0.2460 | 0.2460 | 0.2460 | 0.2460 | 0.0260 | 1.0000 |
| SPLIT GN2 | 0.2456 | 0.2456 | 0.2456 | 0.2456 | 0.0260 | 1.0000 |
| SPLIT GS1 | 0.2662 | 0.2662 | 0.2662 | 0.2662 | 0.0260 | 1.0000 |
| SPLIT GS2 | 0.2691 | 0.2691 | 0.2691 | 0.2691 | 0.0260 | 1.0000 |
| SPLIT MSW | 0.7050 | 0.7050 | 0.7050 | 0.7050 | 0.0519 | 1.0000 |
| SPLIT MNW | 0.6715 | 0.6715 | 0.6715 | 0.6715 | 0.0519 | 1.0000 |
| SPLIT MSE | 0.6469 | 0.6469 | 0.6469 | 0.6469 | 0.0519 | 1.0000 |
| SPLIT MNE | 0.6140 | 0.6140 | 0.6140 | 0.6140 | 0.0519 | 1.0000 |
| SPLIT MN1 | 0.5464 | 0.5464 | 0.5464 | 0.5464 | 0.0519 | 1.0000 |
| SPLIT MN2 | 0.5454 | 0.5454 | 0.5454 | 0.5454 | 0.0519 | 1.0000 |
| SPLIT MS1 | 0.5824 | 0.5824 | 0.5824 | 0.5824 | 0.0519 | 1.0000 |
| SPLIT MS2 | 0.5815 | 0.5815 | 0.5815 | 0.5815 | 0.0519 | 1.0000 |
| SPLIT TSW | 0.3921 | 0.3921 | 0.3921 | 0.3921 | 0.0260 | 1.0000 |
| SPLIT TNW | 0.3796 | 0.3796 | 0.3796 | 0.3796 | 0.0260 | 1.0000 |
| SPLIT TSE | 0.3489 | 0.3489 | 0.3489 | 0.3489 | 0.0260 | 1.0000 |
| SPLIT TNE | 0.3363 | 0.3363 | 0.3363 | 0.3363 | 0.0260 | 1.0000 |
| SPLIT TN1 | 0.3123 | 0.3123 | 0.3123 | 0.3123 | 0.0260 | 1.0000 |
| SPLIT TN2 | 0.3109 | 0.3109 | 0.3109 | 0.3109 | 0.0260 | 1.0000 |
| SPLIT TS1 | 0.3259 | 0.3259 | 0.3259 | 0.3259 | 0.0260 | 1.0000 |
| SPLIT TS2 | 0.3245 | 0.3245 | 0.3245 | 0.3245 | 0.0260 | 1.0000 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| G SW APARTMENT | SPLIT GSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3181 | 0.3181 | 0.3181 | No | 0.0260 | 0.7644 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NW APARTMENT | SPLIT GNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3025 | 0.3025 | 0.3025 | No | 0.0260 | 0.9356 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| OFFICE | SPLIT OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3681 | 0.3681 | 0.3681 | No | 0.0381 | 0.7020 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NE APARTMENT | SPLIT GNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2808 | 0.2808 | 0.2808 | No | 0.0260 | 0.9339 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N1 APARTMENT | SPLIT GN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2460 | 0.2460 | 0.2460 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N2 APARTMENT | SPLIT GN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2456 | 0.2456 | 0.2456 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S1 APARTMENT | SPLIT GS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2662 | 0.2662 | 0.2662 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S2 APARTMENT | SPLIT GS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.2691 | 0.2691 | 0.2691 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SW APARTMENT | SPLIT MSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7050 | 0.7050 | 0.7050 | No | 0.0519 | 0.7199 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NW APARTMENT | SPLIT MNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6715 | 0.6715 | 0.6715 | No | 0.0519 | 0.8955 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SE APARTMENT | SPLIT MSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6469 | 0.6469 | 0.6469 | No | 0.0519 | 0.7187 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NE APARTMENT | SPLIT MNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6140 | 0.6140 | 0.6140 | No | 0.0519 | 0.8935 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N1 APARTMENT | SPLIT MN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5464 | 0.5464 | 0.5464 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N2 APARTMENT | SPLIT MN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5454 | 0.5454 | 0.5454 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S1 APARTMENT | SPLIT MS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5824 | 0.5824 | 0.5824 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S2 APARTMENT | SPLIT MS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5815 | 0.5815 | 0.5815 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SW APARTMENT | SPLIT TSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3921 | 0.3921 | 0.3921 | No | 0.0260 | 0.3842 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NW APARTMENT | SPLIT TNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3796 | 0.3796 | 0.3796 | No | 0.0260 | 0.4331 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SE APARTMENT | SPLIT TSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3489 | 0.3489 | 0.3489 | No | 0.0260 | 0.3839 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NE APARTMENT | SPLIT TNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3363 | 0.3363 | 0.3363 | No | 0.0260 | 0.4326 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N1 APARTMENT | SPLIT TN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3123 | 0.3123 | 0.3123 | No | 0.0260 | 0.6530 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N2 APARTMENT | SPLIT TN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3109 | 0.3109 | 0.3109 | No | 0.0260 | 0.6530 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S1 APARTMENT | SPLIT TS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3259 | 0.3259 | 0.3259 | No | 0.0260 | 0.5480 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S2 APARTMENT | SPLIT TS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3245 | 0.3245 | 0.3245 | No | 0.0260 | 0.5480 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| SPLIT GSW | 0.3181 | 0.3181 | 0.3181 | 0.3181 | 0.0260 | 1.0000 |
| SPLIT GNW | 0.3025 | 0.3025 | 0.3025 | 0.3025 | 0.0260 | 1.0000 |
| SPLIT OFFICE | 0.3681 | 0.3681 | 0.3681 | 0.3681 | 0.0381 | 1.0000 |
| SPLIT GNE | 0.2808 | 0.2808 | 0.2808 | 0.2808 | 0.0260 | 1.0000 |
| SPLIT GN1 | 0.2460 | 0.2460 | 0.2460 | 0.2460 | 0.0260 | 1.0000 |
| SPLIT GN2 | 0.2456 | 0.2456 | 0.2456 | 0.2456 | 0.0260 | 1.0000 |
| SPLIT GS1 | 0.2662 | 0.2662 | 0.2662 | 0.2662 | 0.0260 | 1.0000 |
| SPLIT GS2 | 0.2691 | 0.2691 | 0.2691 | 0.2691 | 0.0260 | 1.0000 |
| SPLIT MSW | 0.7050 | 0.7050 | 0.7050 | 0.7050 | 0.0519 | 1.0000 |
| SPLIT MNW | 0.6715 | 0.6715 | 0.6715 | 0.6715 | 0.0519 | 1.0000 |
| SPLIT MSE | 0.6469 | 0.6469 | 0.6469 | 0.6469 | 0.0519 | 1.0000 |
| SPLIT MNE | 0.6140 | 0.6140 | 0.6140 | 0.6140 | 0.0519 | 1.0000 |
| SPLIT MN1 | 0.5464 | 0.5464 | 0.5464 | 0.5464 | 0.0519 | 1.0000 |
| SPLIT MN2 | 0.5454 | 0.5454 | 0.5454 | 0.5454 | 0.0519 | 1.0000 |
| SPLIT MS1 | 0.5824 | 0.5824 | 0.5824 | 0.5824 | 0.0519 | 1.0000 |
| SPLIT MS2 | 0.5815 | 0.5815 | 0.5815 | 0.5815 | 0.0519 | 1.0000 |
| SPLIT TSW | 0.3921 | 0.3921 | 0.3921 | 0.3921 | 0.0260 | 1.0000 |
| SPLIT TNW | 0.3796 | 0.3796 | 0.3796 | 0.3796 | 0.0260 | 1.0000 |
| SPLIT TSE | 0.3489 | 0.3489 | 0.3489 | 0.3489 | 0.0260 | 1.0000 |
| SPLIT TNE | 0.3363 | 0.3363 | 0.3363 | 0.3363 | 0.0260 | 1.0000 |
| SPLIT TN1 | 0.3123 | 0.3123 | 0.3123 | 0.3123 | 0.0260 | 1.0000 |
| SPLIT TN2 | 0.3109 | 0.3109 | 0.3109 | 0.3109 | 0.0260 | 1.0000 |
| SPLIT TS1 | 0.3259 | 0.3259 | 0.3259 | 0.3259 | 0.0260 | 1.0000 |
| SPLIT TS2 | 0.3245 | 0.3245 | 0.3245 | 0.3245 | 0.0260 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Sec1.1A-General Information| Data | |
| Weather File | RUNPERIOD 1 ** Tampa-MacDill AFB FL USA TMY3 WMO#=747880 |
| Total gross floor area [m2] | 3134.61 |
| Principal Heating Source | Electricity |
| Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
| G SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| OFFICE | 88.25 | 88.25 | 0.00 | 33.56 |
| G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M SE APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T SE APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| G CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| M CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| Totals | 3134.61 | 2823.98 | 310.64 |
| Data | |
| Number of hours heating loads not met | 0.00 |
| Number of hours cooling loads not met | 0.00 |
| Number of hours not met | 0.00 |
| Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
| None |
| Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
| Heating -- General | 1.64 | 5133.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling -- General | 258.54 | 28765.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- LightsWired | 67.97 | 3560.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- LightsPlugIn | 5.02 | 479.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting -- General | 33.02 | 2101.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- ElevatorLift | 67.41 | 3772.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- ElevatorLightsFan | 0.49 | 31.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- MiscPlug | 386.12 | 18442.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- General | 122.14 | 8952.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps -- General | 0.46 | 14.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems -- WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems -- Water Heater | 0.00 | 0.00 | 354.15 | 24157.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Process Subtotal [GJ] | Total Energy Use [GJ] | |
| Electricity | 454.01 | 942.81 |
| Natural Gas | 0.00 | 354.15 |
| Additional | 0.00 | 0.00 |
| Total | 454.01 | 1296.96 |
| Process Subtotal [$] | Total Energy Cost [$] | |
| Electricity | 0.00 | |
| Natural Gas | 0.00 | |
| Additional | 0.00 | |
| Total | 0.00 |
| Rated Capacity [kW] | Annual Energy Generated [GJ] | |
| Photovoltaic | 0.00 | 0.00 |
| Wind | 0.00 | 0.00 |
| Electricty [MJ/m2] | |
| Interior Lighting (All) | 23.29 |
| Space Heating | 0.52 |
| Space Cooling | 82.48 |
| Fans (All) | 38.97 |
| Service Water Heating | 0.00 |
| Receptacle Equipment | 144.84 |
| Miscellaneous (All) | 300.77 |
| Subtotal | 300.77 |
| Natural Gas [MJ/m2] | |
| Space Heating | 0.00 |
| Service Water Heating | 112.98 |
| Miscellaneous (All) | 112.98 |
| Subtotal | 112.98 |
| Additional [MJ/m2] | |
| Subtotal | 0.00 |
| Miscellaneous | 0.00 |
| Percent [%] | |
| Interior Lighting (All) | 5.63 |
| Space Heating | 0.13 |
| Space Cooling | 19.93 |
| Fans (All) | 9.42 |
| Service Water Heating | 27.31 |
| Receptacle Equipment | 35.01 |
| Miscellaneous | 2.58 |
| Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
| ELEVATOR_RUNNING_SCH | 146. | 3285. |
| ELEVATOR_STANDBY_SCH | 8201. | 8760. |
| OCC_APT_SCH_STAY_HOME_FAMILY | 5993. | 8760. |
| OCC_APT_SCH_CORRIDOR | 5993. | 8760. |
| OCC_APT_SCH_WORKING_FAMILY | 5845. | 6055. |
| OCC_OFF_SCH | 2210. | 2340. |
| OCC_OFF_W_SB_SCH | 1820. | 1820. |
| LTG_SCH_OFFICE | 2435. | 8760. |
| LTG_SCH_CORRIDOR | 6570. | 8760. |
| LTG_SCH_APARTMENT_HARDWIRED | 527. | 8760. |
| LTG_SCH_APARTMENT_PLUGIN | 527. | 8760. |
| EQP_APT_SCH | 5763. | 8760. |
| EQP_OFF_SCH | 3614. | 8760. |
| INF_APT_SCH | 8760. | 8760. |
| INF_OFF_SCH | 8760. | 8760. |
| INF_COR_SCH | 8760. | 8760. |
| INFIL_DOOR_OPENING_SCH | 1466. | 5840. |
| ALL OFF | 0. | 0. |
| ALL ON | 8760. | 8760. |
| ALWAYS_ON | 8760. | 8760. |
| ALLON_EXCEPT_DD | 8760. | 8760. |
| EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
| FAN_OFF_W_SB_SCH | 8240. | 8240. |
| APT_DHW_SCH | 4592. | 8760. |
| EXTERIOR_LTG_SCH | 4380. | 4380. |
| ELEV_LIGHT_FAN_SCH_24_7 | 8760. | 8760. |
| ELEV_LIGHT_FAN_SCH_ADD_DF | 2154. | 8760. |
| SLIDING_DOORS_VENTILATION_AVAILABILITY_SCH | 5840. | 5840. |
| First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
| HTGSETP_APT_SCH | APTHEATINGSETPOINT | January | 21.10 | 365 | 21.10 | 365 |
| HTGSETP_DESIGN_OFF_SCH | OFFHEATINGSETPOINT | January | 21.10 | 365 | 21.10 | 365 |
| CLGSETP_APT_SCH | APTCOOLINGSETPOINT | July | 24.00 | 365 | 24.00 | 365 |
| CLGSETP_DESIGN_OFF_SCH | OFFCOOLINGSETPOINT | July | 23.90 | 365 | 23.90 | 365 |
| S HTGSETP_APT_SCH | S APARTMENT DUAL SP CONTROL | January | 21.10 | 365 | 21.10 | 365 |
| S CLGSETP_APT_SCH | S APARTMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
| N HTGSETP_APT_SCH | N APARTMENT DUAL SP CONTROL | January | 21.10 | 365 | 21.10 | 365 |
| N CLGSETP_APT_SCH | N APARTMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
| HTGSETP_OFF_SCH_NO_OPTIMUM | OFFICE DUAL SP CONTROL | January | 21.10 | 365 | 15.60 | 365 |
| CLGSETP_OFF_SCH_NO_OPTIMUM | OFFICE DUAL SP CONTROL | July | 24.00 | 365 | 29.40 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Heat Index Hours| Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| G SW APARTMENT | 8747.00 | 13.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 8754.33 | 5.67 | 0.00 | 0.00 | 0.00 |
| OFFICE | 4945.00 | 3149.33 | 665.67 | 0.00 | 0.00 |
| G NE APARTMENT | 8750.17 | 9.83 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 8759.17 | 0.83 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 8759.17 | 0.83 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 8755.00 | 5.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 8743.33 | 16.67 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 8749.17 | 10.83 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 8758.50 | 1.50 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 8746.17 | 13.83 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 8758.33 | 1.67 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 8759.83 | 0.17 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 8759.83 | 0.17 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 8755.83 | 4.17 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 8755.83 | 4.17 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 8668.50 | 91.50 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 8671.67 | 88.33 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 8670.00 | 90.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 8675.50 | 84.50 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 8724.17 | 35.83 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 8724.83 | 35.17 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 8704.00 | 56.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 8704.67 | 55.33 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 2913.00 | 5278.00 | 569.00 | 0.00 | 0.00 |
| G CORRIDOR | 3249.67 | 4149.50 | 1360.83 | 0.00 | 0.00 |
| M CORRIDOR | 1403.50 | 7356.50 | 0.00 | 0.00 | 0.00 |
| Min | 1403.50 | 0.17 | 0.00 | 0.00 | 0.00 |
| Max | 8759.83 | 7356.50 | 1360.83 | 0.00 | 0.00 |
| Average | 7902.45 | 761.42 | 96.13 | 0.00 | 0.00 |
| Sum | 213366.17 | 20558.33 | 2595.50 | 0.00 | 0.00 |
| Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| G SW APARTMENT | 11815.33 | 14.67 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 10578.00 | 7.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 7000.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 10579.67 | 5.33 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 10584.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 10584.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 11826.50 | 3.50 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 11813.17 | 16.83 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 11820.67 | 9.33 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 10582.17 | 2.83 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 11820.17 | 9.83 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 10584.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 10584.67 | 0.33 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 10584.67 | 0.33 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 11827.17 | 2.83 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 11827.17 | 2.83 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 11728.83 | 101.17 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 10463.50 | 121.50 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 11756.33 | 73.67 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 10528.50 | 56.50 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 10534.33 | 50.67 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 10537.00 | 48.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 11770.17 | 59.83 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 11774.00 | 56.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 7882.50 | 13740.33 | 1372.17 | 0.00 | 0.00 |
| G CORRIDOR | 8128.83 | 10297.00 | 4569.17 | 0.00 | 0.00 |
| M CORRIDOR | 3740.00 | 19255.00 | 0.00 | 0.00 | 0.00 |
| Min | 3740.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 11827.17 | 19255.00 | 4569.17 | 0.00 | 0.00 |
| Average | 10490.94 | 1627.35 | 220.05 | 0.00 | 0.00 |
| Sum | 283255.33 | 43938.33 | 5941.33 | 0.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| G SW APARTMENT | 7267.50 | 1492.50 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 7153.00 | 1607.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 4145.17 | 4471.67 | 143.17 | 0.00 | 0.00 |
| G NE APARTMENT | 7162.67 | 1597.33 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 7030.83 | 1729.17 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 7032.83 | 1727.17 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 7140.67 | 1619.33 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 7465.17 | 1294.83 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 7222.00 | 1538.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 7085.67 | 1674.33 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 7221.50 | 1538.50 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 7110.83 | 1649.17 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 6855.50 | 1904.50 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 6857.67 | 1902.33 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 6983.67 | 1776.33 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 6983.33 | 1776.67 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 6667.00 | 2093.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 6519.17 | 2240.83 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 6671.83 | 2088.17 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 6528.33 | 2231.67 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 6563.33 | 2196.67 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 6562.83 | 2197.17 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 6685.67 | 2074.33 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 6684.83 | 2075.17 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 77.17 | 6354.50 | 2328.33 | 0.00 | 0.00 |
| G CORRIDOR | 2169.67 | 5280.17 | 1310.17 | 0.00 | 0.00 |
| M CORRIDOR | 0.00 | 7684.17 | 1075.83 | 0.00 | 0.00 |
| Min | 0.00 | 1294.83 | 0.00 | 0.00 | 0.00 |
| Max | 7465.17 | 7684.17 | 2328.33 | 0.00 | 0.00 |
| Average | 6142.51 | 2437.58 | 179.91 | 0.00 | 0.00 |
| Sum | 165847.83 | 65814.67 | 4857.50 | 0.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| G SW APARTMENT | 9770.00 | 2060.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 8576.83 | 2008.17 | 0.00 | 0.00 | 0.00 |
| OFFICE | 6856.67 | 143.33 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 8529.33 | 2055.67 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 8398.00 | 2187.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 8400.33 | 2184.67 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 9554.67 | 2275.33 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 10101.17 | 1728.83 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 9709.50 | 2120.50 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 8531.50 | 2053.50 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 9657.83 | 2172.17 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 8474.33 | 2110.67 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 8207.17 | 2377.83 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 8204.00 | 2381.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 9311.33 | 2518.67 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 9308.83 | 2521.17 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 8735.33 | 3094.67 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 7538.17 | 3046.83 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 8651.67 | 3178.33 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 7410.00 | 3175.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 7650.17 | 2934.83 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 7643.50 | 2941.50 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 8792.83 | 3037.17 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 8788.50 | 3041.50 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 166.50 | 17171.00 | 5657.50 | 0.00 | 0.00 |
| G CORRIDOR | 5100.67 | 13176.33 | 4718.00 | 0.00 | 0.00 |
| M CORRIDOR | 0.00 | 20065.67 | 2929.33 | 0.00 | 0.00 |
| Min | 0.00 | 143.33 | 0.00 | 0.00 | 0.00 |
| Max | 10101.17 | 20065.67 | 5657.50 | 0.00 | 0.00 |
| Average | 7854.40 | 3991.16 | 492.77 | 0.00 | 0.00 |
| Sum | 212068.83 | 107761.33 | 13304.83 | 0.00 | 0.00 |
| SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
| None |
| SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
| None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
CO2 Level Hours| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Illuminance Level Hours| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 2A
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.572 |
| February | 15.490 |
| March | 17.074 |
| April | 21.231 |
| May | 26.899 |
| June | 27.606 |
| July | 27.937 |
| August | 27.434 |
| September | 26.232 |
| October | 24.234 |
| November | 18.911 |
| December | 15.677 |
| Annual Sum or Average | 21.892 |
| Minimum of Months | 13.572 |
| Maximum of Months | 27.937 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.572 |
| February | 15.490 |
| March | 17.074 |
| April | 21.231 |
| May | 26.899 |
| June | 27.606 |
| July | 27.937 |
| August | 27.434 |
| September | 26.232 |
| October | 24.234 |
| November | 18.911 |
| December | 15.677 |
| Annual Sum or Average | 21.892 |
| Minimum of Months | 13.572 |
| Maximum of Months | 27.937 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.572 |
| February | 15.490 |
| March | 17.074 |
| April | 21.231 |
| May | 26.899 |
| June | 27.606 |
| July | 27.937 |
| August | 27.434 |
| September | 26.232 |
| October | 24.234 |
| November | 18.911 |
| December | 15.677 |
| Annual Sum or Average | 21.892 |
| Minimum of Months | 13.572 |
| Maximum of Months | 27.937 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2019
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.572 |
| February | 15.490 |
| March | 17.074 |
| April | 21.231 |
| May | 26.899 |
| June | 27.606 |
| July | 27.937 |
| August | 27.434 |
| September | 26.232 |
| October | 24.234 |
| November | 18.911 |
| December | 15.677 |
| Annual Sum or Average | 21.892 |
| Minimum of Months | 13.572 |
| Maximum of Months | 27.937 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.572 |
| February | 15.490 |
| March | 17.074 |
| April | 21.231 |
| May | 26.899 |
| June | 27.606 |
| July | 27.937 |
| August | 27.434 |
| September | 26.232 |
| October | 24.234 |
| November | 18.911 |
| December | 15.677 |
| Annual Sum or Average | 21.892 |
| Minimum of Months | 13.572 |
| Maximum of Months | 27.937 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_FL_TAMPA
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.572 |
| February | 15.490 |
| March | 17.074 |
| April | 21.231 |
| May | 26.899 |
| June | 27.606 |
| July | 27.937 |
| August | 27.434 |
| September | 26.232 |
| October | 24.234 |
| November | 18.911 |
| December | 15.677 |
| Annual Sum or Average | 21.892 |
| Minimum of Months | 13.572 |
| Maximum of Months | 27.937 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.572 |
| February | 15.490 |
| March | 17.074 |
| April | 21.231 |
| May | 26.899 |
| June | 27.606 |
| July | 27.937 |
| August | 27.434 |
| September | 26.232 |
| October | 24.234 |
| November | 18.911 |
| December | 15.677 |
| Annual Sum or Average | 21.892 |
| Minimum of Months | 13.572 |
| Maximum of Months | 27.937 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PERFORMANCEPATHPROPOSED
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.572 |
| February | 15.490 |
| March | 17.074 |
| April | 21.231 |
| May | 26.899 |
| June | 27.606 |
| July | 27.937 |
| August | 27.434 |
| September | 26.232 |
| October | 24.234 |
| November | 18.911 |
| December | 15.677 |
| Annual Sum or Average | 21.892 |
| Minimum of Months | 13.572 |
| Maximum of Months | 27.937 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.572 |
| February | 15.490 |
| March | 17.074 |
| April | 21.231 |
| May | 26.899 |
| June | 27.606 |
| July | 27.937 |
| August | 27.434 |
| September | 26.232 |
| October | 24.234 |
| November | 18.911 |
| December | 15.677 |
| Annual Sum or Average | 21.892 |
| Minimum of Months | 13.572 |
| Maximum of Months | 27.937 |
Report: ZoneCoolingSummaryMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.108322E+10 | 5304.74 | 15-JAN-18:02 | 16.92 | 13.14 | 0.132460E+09 | 103.05 | 15-JAN-16:49 | 16.92 | 13.14 |
| February | 0.900286E+09 | 5248.65 | 09-FEB-18:42 | 17.98 | 14.53 | 0.117325E+09 | 103.17 | 27-FEB-18:10 | 22.33 | 19.20 |
| March | 0.850220E+09 | 5203.67 | 04-MAR-22:02 | 18.28 | 13.75 | 0.124761E+09 | 97.64 | 17-MAR-17:19 | 22.73 | 19.18 |
| April | 0.120483E+10 | 5278.59 | 16-APR-20:42 | 14.58 | 11.99 | 0.131492E+09 | 97.10 | 28-APR-19:19 | 23.63 | 22.40 |
| May | 0.225536E+10 | 4275.63 | 27-MAY-18:52 | 25.00 | 22.66 | 0.128111E+09 | 94.72 | 17-MAY-20:49 | 25.00 | 22.66 |
| June | 0.241323E+10 | 4062.21 | 06-JUN-20:12 | 22.80 | 21.46 | 0.121583E+09 | 94.27 | 06-JUN-19:00 | 22.80 | 21.46 |
| July | 0.277142E+10 | 4289.57 | 12-JUL-17:32 | 23.90 | 22.65 | 0.129960E+09 | 103.00 | 12-JUL-17:40 | 23.90 | 22.65 |
| August | 0.312337E+10 | 4282.63 | 16-AUG-16:12 | 23.07 | 22.30 | 0.126360E+09 | 101.56 | 16-AUG-17:30 | 21.70 | 20.88 |
| September | 0.292409E+10 | 4505.65 | 06-SEP-20:02 | 24.60 | 22.43 | 0.128658E+09 | 107.40 | 02-SEP-17:49 | 24.60 | 22.43 |
| October | 0.295265E+10 | 5335.40 | 17-OCT-16:42 | 22.33 | 16.01 | 0.134099E+09 | 106.49 | 29-OCT-16:00 | 23.00 | 17.32 |
| November | 0.188293E+10 | 5299.00 | 30-NOV-22:22 | 15.05 | 12.93 | 0.133205E+09 | 102.48 | 04-NOV-17:40 | 15.05 | 12.93 |
| December | 0.148927E+10 | 5477.47 | 17-DEC-17:01 | 14.50 | 10.51 | 0.135560E+09 | 103.65 | 16-DEC-18:30 | 14.50 | 10.51 |
| Annual Sum or Average | 0.238509E+11 | 0.154357E+10 | ||||||||
| Minimum of Months | 0.850220E+09 | 4062.21 | 14.50 | 10.51 | 0.117325E+09 | 94.27 | 14.50 | 10.51 | ||
| Maximum of Months | 0.312337E+10 | 5477.47 | 25.00 | 22.66 | 0.135560E+09 | 107.40 | 25.00 | 22.66 |
Report: ZoneCoolingSummaryMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.451031E+09 | 4777.06 | 02-JAN-22:12 | 13.33 | 10.29 | 0.119863E+09 | 92.30 | 19-JAN-21:10 | 21.00 | 21.00 |
| February | 0.429717E+09 | 4438.56 | 26-FEB-19:02 | 20.42 | 18.26 | 0.109156E+09 | 87.96 | 02-FEB-22:00 | 20.42 | 18.26 |
| March | 0.538978E+09 | 4917.84 | 04-MAR-22:52 | 18.20 | 13.98 | 0.124605E+09 | 87.32 | 29-MAR-21:30 | 21.10 | 19.57 |
| April | 0.990690E+09 | 5048.44 | 16-APR-20:42 | 14.58 | 11.99 | 0.131252E+09 | 93.50 | 23-APR-20:10 | 22.43 | 20.40 |
| May | 0.224034E+10 | 4122.21 | 27-MAY-18:52 | 25.00 | 22.66 | 0.131069E+09 | 94.75 | 17-MAY-20:49 | 25.00 | 22.66 |
| June | 0.248316E+10 | 3876.52 | 06-JUN-20:12 | 22.80 | 21.46 | 0.125790E+09 | 92.37 | 06-JUN-21:49 | 22.80 | 20.89 |
| July | 0.279853E+10 | 4153.68 | 12-JUL-16:32 | 23.90 | 22.40 | 0.129652E+09 | 96.63 | 12-JUL-21:40 | 23.90 | 22.65 |
| August | 0.300674E+10 | 4044.27 | 16-AUG-16:12 | 23.07 | 22.30 | 0.131056E+09 | 98.06 | 12-AUG-20:10 | 23.07 | 22.30 |
| September | 0.262999E+10 | 4426.85 | 02-SEP-17:12 | 23.53 | 21.83 | 0.129484E+09 | 99.13 | 02-SEP-20:19 | 23.30 | 22.28 |
| October | 0.232357E+10 | 5020.06 | 17-OCT-18:12 | 20.47 | 16.00 | 0.135293E+09 | 97.65 | 01-OCT-20:10 | 20.47 | 16.00 |
| November | 0.108979E+10 | 5050.10 | 30-NOV-22:22 | 15.05 | 12.93 | 0.133246E+09 | 96.02 | 05-NOV-20:19 | 15.05 | 12.93 |
| December | 0.744521E+09 | 5053.59 | 17-DEC-17:32 | 13.00 | 9.82 | 0.129068E+09 | 94.74 | 11-DEC-21:10 | 13.00 | 9.82 |
| Annual Sum or Average | 0.197270E+11 | 0.152953E+10 | ||||||||
| Minimum of Months | 0.429717E+09 | 3876.52 | 13.00 | 9.82 | 0.109156E+09 | 87.32 | 13.00 | 9.82 | ||
| Maximum of Months | 0.300674E+10 | 5053.59 | 25.00 | 22.66 | 0.135293E+09 | 99.13 | 25.00 | 22.66 |
Report: ZoneCoolingSummaryMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.112761E+10 | 6680.28 | 03-JAN-07:01 | 2.33 | 0.16 | 66395243.90 | 133.53 | 17-JAN-15:20 | 25.00 | 19.63 |
| February | 0.965801E+09 | 5054.04 | 24-FEB-07:01 | 15.45 | 15.45 | 63119680.86 | 133.53 | 27-FEB-16:10 | 25.32 | 20.49 |
| March | 0.944500E+09 | 5613.00 | 01-MAR-07:01 | 15.30 | 14.01 | 76270848.41 | 133.52 | 02-MAR-15:39 | 19.07 | 14.25 |
| April | 0.102173E+10 | 5683.69 | 18-APR-06:01 | 16.78 | 15.05 | 67285565.62 | 133.53 | 28-APR-14:50 | 33.20 | 23.05 |
| May | 0.177734E+10 | 4694.85 | 12-MAY-06:01 | 23.40 | 20.68 | 74018915.35 | 133.54 | 30-MAY-09:00 | 28.90 | 24.51 |
| June | 0.190094E+10 | 4849.25 | 07-JUN-06:01 | 21.38 | 19.31 | 74018453.21 | 133.54 | 19-JUN-10:20 | 30.97 | 25.88 |
| July | 0.193977E+10 | 3957.76 | 17-JUL-06:01 | 24.60 | 23.38 | 67292322.69 | 133.84 | 24-JUL-07:10 | 27.48 | 25.67 |
| August | 0.235136E+10 | 4245.40 | 04-AUG-06:01 | 25.68 | 23.49 | 77386876.81 | 133.57 | 21-AUG-07:10 | 26.33 | 23.97 |
| September | 0.201805E+10 | 4623.92 | 22-SEP-06:01 | 21.70 | 19.78 | 67291790.03 | 133.56 | 05-SEP-07:10 | 21.70 | 19.78 |
| October | 0.219685E+10 | 6601.57 | 17-OCT-06:01 | 15.83 | 10.49 | 70657659.34 | 133.54 | 25-OCT-07:10 | 24.17 | 24.17 |
| November | 0.163004E+10 | 6492.84 | 14-NOV-07:01 | 15.08 | 11.13 | 67290002.66 | 133.54 | 07-NOV-15:00 | 15.08 | 11.13 |
| December | 0.127392E+10 | 6596.43 | 18-DEC-07:01 | 2.50 | 0.21 | 66737219.64 | 133.54 | 11-DEC-13:30 | 2.50 | 0.21 |
| Annual Sum or Average | 0.191479E+11 | 0.837765E+09 | ||||||||
| Minimum of Months | 0.944500E+09 | 3957.76 | 2.33 | 0.16 | 63119680.86 | 133.52 | 2.50 | 0.21 | ||
| Maximum of Months | 0.235136E+10 | 6680.28 | 25.68 | 23.49 | 77386876.81 | 133.84 | 33.20 | 25.88 |
Report: ZoneCoolingSummaryMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.435589E+09 | 4509.98 | 02-JAN-22:12 | 13.33 | 10.29 | 0.119293E+09 | 91.92 | 19-JAN-21:10 | 21.00 | 21.00 |
| February | 0.401914E+09 | 3991.84 | 27-FEB-18:42 | 20.87 | 18.76 | 0.108777E+09 | 87.32 | 02-FEB-22:00 | 20.87 | 18.76 |
| March | 0.551606E+09 | 4639.84 | 19-MAR-18:22 | 14.40 | 9.41 | 0.124545E+09 | 87.89 | 29-MAR-21:30 | 21.10 | 19.57 |
| April | 0.981483E+09 | 4748.80 | 16-APR-20:42 | 14.58 | 11.99 | 0.130817E+09 | 92.44 | 28-APR-21:10 | 23.82 | 23.08 |
| May | 0.231256E+10 | 3937.92 | 13-MAY-12:52 | 25.00 | 22.66 | 0.131139E+09 | 94.55 | 19-MAY-20:10 | 23.48 | 22.69 |
| June | 0.253255E+10 | 3716.56 | 01-JUN-14:02 | 29.60 | 22.94 | 0.125809E+09 | 92.50 | 06-JUN-20:19 | 22.80 | 21.46 |
| July | 0.287980E+10 | 3792.24 | 12-JUL-15:42 | 23.72 | 21.64 | 0.129638E+09 | 96.10 | 12-JUL-21:40 | 23.90 | 22.65 |
| August | 0.302790E+10 | 3815.23 | 16-AUG-16:12 | 23.07 | 22.30 | 0.131026E+09 | 97.16 | 12-AUG-20:10 | 23.07 | 22.30 |
| September | 0.263359E+10 | 4101.17 | 02-SEP-17:12 | 23.53 | 21.83 | 0.129436E+09 | 98.34 | 27-SEP-21:10 | 22.70 | 21.53 |
| October | 0.230842E+10 | 4765.33 | 17-OCT-18:12 | 20.47 | 16.00 | 0.134927E+09 | 96.71 | 03-OCT-20:00 | 20.47 | 16.00 |
| November | 0.108455E+10 | 4771.93 | 30-NOV-22:22 | 15.05 | 12.93 | 0.132935E+09 | 94.96 | 06-NOV-21:19 | 15.05 | 12.93 |
| December | 0.704424E+09 | 4765.05 | 01-DEC-17:12 | 20.00 | 14.89 | 0.128095E+09 | 94.50 | 11-DEC-21:10 | 21.83 | 19.89 |
| Annual Sum or Average | 0.198544E+11 | 0.152644E+10 | ||||||||
| Minimum of Months | 0.401914E+09 | 3716.56 | 13.33 | 9.41 | 0.108777E+09 | 87.32 | 15.05 | 12.93 | ||
| Maximum of Months | 0.302790E+10 | 4771.93 | 29.60 | 22.94 | 0.134927E+09 | 98.34 | 23.90 | 23.08 |
Report: ZoneCoolingSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.483313E+09 | 4084.58 | 02-JAN-22:12 | 13.33 | 10.29 | 0.126104E+09 | 91.95 | 19-JAN-21:10 | 21.00 | 21.00 |
| February | 0.453028E+09 | 3576.84 | 26-FEB-19:02 | 20.42 | 18.26 | 0.114257E+09 | 89.32 | 02-FEB-22:00 | 20.42 | 18.26 |
| March | 0.594452E+09 | 4221.14 | 04-MAR-22:52 | 18.20 | 13.98 | 0.128788E+09 | 88.05 | 29-MAR-21:30 | 21.10 | 19.57 |
| April | 0.963074E+09 | 4301.76 | 16-APR-20:42 | 14.58 | 11.99 | 0.131210E+09 | 92.38 | 28-APR-20:00 | 23.80 | 23.06 |
| May | 0.199991E+10 | 3430.80 | 13-MAY-12:52 | 25.00 | 22.66 | 0.131073E+09 | 93.02 | 19-MAY-20:10 | 23.48 | 22.69 |
| June | 0.215173E+10 | 3265.44 | 06-JUN-20:12 | 22.80 | 21.46 | 0.125781E+09 | 92.53 | 06-JUN-20:19 | 22.80 | 21.46 |
| July | 0.240284E+10 | 3275.87 | 12-JUL-15:42 | 23.72 | 21.64 | 0.129597E+09 | 95.12 | 12-JUL-21:40 | 23.90 | 22.65 |
| August | 0.250813E+10 | 3360.60 | 16-AUG-16:12 | 23.07 | 22.30 | 0.130910E+09 | 95.33 | 16-AUG-20:30 | 20.80 | 20.74 |
| September | 0.222704E+10 | 3576.68 | 06-SEP-20:02 | 24.60 | 22.43 | 0.129196E+09 | 97.80 | 27-SEP-21:10 | 22.70 | 21.53 |
| October | 0.198045E+10 | 4289.86 | 17-OCT-18:12 | 20.47 | 16.00 | 0.134720E+09 | 95.21 | 16-OCT-21:10 | 20.47 | 16.00 |
| November | 0.106732E+10 | 4317.95 | 30-NOV-22:22 | 15.05 | 12.93 | 0.132842E+09 | 95.18 | 29-NOV-21:10 | 15.05 | 12.93 |
| December | 0.778031E+09 | 4318.72 | 17-DEC-17:32 | 13.00 | 9.82 | 0.131926E+09 | 94.58 | 11-DEC-21:10 | 13.00 | 9.82 |
| Annual Sum or Average | 0.176093E+11 | 0.154640E+10 | ||||||||
| Minimum of Months | 0.453028E+09 | 3265.44 | 13.00 | 9.82 | 0.114257E+09 | 88.05 | 13.00 | 9.82 | ||
| Maximum of Months | 0.250813E+10 | 4318.72 | 25.00 | 22.66 | 0.134720E+09 | 97.80 | 23.90 | 23.06 |
Report: ZoneCoolingSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.482761E+09 | 4078.67 | 02-JAN-22:12 | 13.33 | 10.29 | 0.126121E+09 | 91.88 | 19-JAN-21:10 | 21.00 | 21.00 |
| February | 0.452353E+09 | 3569.12 | 26-FEB-19:02 | 20.42 | 18.26 | 0.114261E+09 | 89.24 | 02-FEB-22:00 | 20.42 | 18.26 |
| March | 0.596114E+09 | 4213.90 | 04-MAR-22:52 | 18.20 | 13.98 | 0.128832E+09 | 88.15 | 29-MAR-21:30 | 21.10 | 19.57 |
| April | 0.964586E+09 | 4295.77 | 16-APR-20:42 | 14.58 | 11.99 | 0.131211E+09 | 92.34 | 28-APR-20:00 | 23.80 | 23.06 |
| May | 0.200340E+10 | 3429.14 | 13-MAY-12:52 | 25.00 | 22.66 | 0.131075E+09 | 93.04 | 19-MAY-20:10 | 23.48 | 22.69 |
| June | 0.215407E+10 | 3260.50 | 01-JUN-14:02 | 29.60 | 22.94 | 0.125780E+09 | 92.51 | 06-JUN-20:19 | 22.80 | 21.46 |
| July | 0.240632E+10 | 3273.19 | 12-JUL-15:42 | 23.72 | 21.64 | 0.129597E+09 | 95.10 | 12-JUL-21:40 | 23.90 | 22.65 |
| August | 0.250905E+10 | 3356.20 | 16-AUG-16:12 | 23.07 | 22.30 | 0.130907E+09 | 95.30 | 16-AUG-20:30 | 20.80 | 20.74 |
| September | 0.222723E+10 | 3570.83 | 06-SEP-20:02 | 24.60 | 22.43 | 0.129194E+09 | 97.81 | 27-SEP-21:10 | 22.70 | 21.53 |
| October | 0.198002E+10 | 4283.79 | 17-OCT-18:12 | 20.47 | 16.00 | 0.134695E+09 | 95.20 | 16-OCT-21:10 | 20.47 | 16.00 |
| November | 0.106759E+10 | 4312.54 | 30-NOV-22:22 | 15.05 | 12.93 | 0.132844E+09 | 95.08 | 29-NOV-21:10 | 15.05 | 12.93 |
| December | 0.774506E+09 | 4312.98 | 17-DEC-17:32 | 13.00 | 9.82 | 0.131875E+09 | 94.56 | 11-DEC-21:10 | 13.00 | 9.82 |
| Annual Sum or Average | 0.176180E+11 | 0.154639E+10 | ||||||||
| Minimum of Months | 0.452353E+09 | 3260.50 | 13.00 | 9.82 | 0.114261E+09 | 88.15 | 13.00 | 9.82 | ||
| Maximum of Months | 0.250905E+10 | 4312.98 | 29.60 | 22.94 | 0.134695E+09 | 97.81 | 23.90 | 23.06 |
Report: ZoneCoolingSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.130236E+10 | 4653.75 | 28-JAN-20:12 | 14.67 | 12.54 | 0.134717E+09 | 99.71 | 15-JAN-16:49 | 14.67 | 12.54 |
| February | 0.104957E+10 | 4620.75 | 08-FEB-21:02 | 13.20 | 11.12 | 0.120037E+09 | 98.24 | 27-FEB-18:10 | 22.33 | 19.20 |
| March | 0.963871E+09 | 4566.95 | 04-MAR-22:02 | 18.28 | 13.75 | 0.128183E+09 | 93.84 | 18-MAR-17:30 | 23.30 | 21.04 |
| April | 0.119407E+10 | 4628.66 | 16-APR-20:42 | 14.58 | 11.99 | 0.131714E+09 | 94.46 | 28-APR-19:19 | 23.63 | 22.40 |
| May | 0.202559E+10 | 3661.87 | 13-MAY-21:52 | 23.90 | 21.88 | 0.128129E+09 | 93.10 | 19-MAY-20:10 | 23.48 | 22.69 |
| June | 0.209064E+10 | 3527.82 | 06-JUN-20:12 | 22.80 | 21.46 | 0.121577E+09 | 92.51 | 06-JUN-20:19 | 22.80 | 21.46 |
| July | 0.238683E+10 | 3608.45 | 12-JUL-15:32 | 23.53 | 21.40 | 0.129920E+09 | 96.00 | 12-JUL-17:40 | 23.90 | 22.65 |
| August | 0.263728E+10 | 3667.28 | 16-AUG-16:12 | 23.07 | 22.30 | 0.126227E+09 | 97.43 | 16-AUG-17:30 | 21.70 | 20.88 |
| September | 0.253693E+10 | 3873.41 | 06-SEP-20:02 | 24.60 | 22.43 | 0.128409E+09 | 100.44 | 02-SEP-17:49 | 24.60 | 22.43 |
| October | 0.262897E+10 | 4647.10 | 28-OCT-21:52 | 15.00 | 12.15 | 0.133908E+09 | 101.62 | 29-OCT-16:00 | 23.00 | 17.32 |
| November | 0.189648E+10 | 4649.43 | 30-NOV-22:22 | 15.05 | 12.93 | 0.133404E+09 | 99.61 | 05-NOV-09:00 | 15.05 | 12.93 |
| December | 0.162766E+10 | 4692.88 | 17-DEC-17:22 | 13.50 | 10.06 | 0.136837E+09 | 101.72 | 17-DEC-10:20 | 13.50 | 10.06 |
| Annual Sum or Average | 0.223402E+11 | 0.155306E+10 | ||||||||
| Minimum of Months | 0.963871E+09 | 3527.82 | 13.20 | 10.06 | 0.120037E+09 | 92.51 | 13.50 | 10.06 | ||
| Maximum of Months | 0.263728E+10 | 4692.88 | 24.60 | 22.43 | 0.136837E+09 | 101.72 | 24.60 | 22.69 |
Report: ZoneCoolingSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.132480E+10 | 4688.06 | 28-JAN-20:12 | 14.67 | 12.54 | 0.134839E+09 | 101.10 | 01-JAN-20:49 | 14.67 | 12.54 |
| February | 0.105649E+10 | 4654.36 | 08-FEB-21:02 | 13.20 | 11.12 | 0.119977E+09 | 98.82 | 27-FEB-18:10 | 22.33 | 19.20 |
| March | 0.996796E+09 | 4604.15 | 04-MAR-22:02 | 18.28 | 13.75 | 0.128257E+09 | 94.20 | 18-MAR-17:30 | 23.30 | 21.04 |
| April | 0.126271E+10 | 4668.80 | 16-APR-20:42 | 14.58 | 11.99 | 0.132130E+09 | 95.32 | 28-APR-19:19 | 23.63 | 22.40 |
| May | 0.223177E+10 | 3758.68 | 13-MAY-21:52 | 23.90 | 21.88 | 0.128344E+09 | 94.21 | 19-MAY-20:10 | 23.48 | 22.69 |
| June | 0.230844E+10 | 3609.60 | 06-JUN-20:12 | 22.80 | 21.46 | 0.121690E+09 | 93.63 | 06-JUN-19:00 | 22.80 | 21.46 |
| July | 0.264925E+10 | 3697.80 | 12-JUL-15:32 | 23.53 | 21.40 | 0.129952E+09 | 96.99 | 12-JUL-17:40 | 23.90 | 22.65 |
| August | 0.288555E+10 | 3739.41 | 16-AUG-16:12 | 23.07 | 22.30 | 0.126384E+09 | 98.52 | 16-AUG-17:30 | 21.70 | 20.88 |
| September | 0.276187E+10 | 3932.13 | 06-SEP-20:02 | 24.60 | 22.43 | 0.128670E+09 | 102.24 | 02-SEP-17:49 | 24.60 | 22.43 |
| October | 0.283592E+10 | 4688.87 | 17-OCT-16:42 | 22.33 | 16.01 | 0.134337E+09 | 102.38 | 29-OCT-16:00 | 23.00 | 17.32 |
| November | 0.198655E+10 | 4689.59 | 30-NOV-22:22 | 15.05 | 12.93 | 0.133799E+09 | 101.45 | 05-NOV-09:00 | 15.05 | 12.93 |
| December | 0.167685E+10 | 4830.05 | 17-DEC-17:01 | 14.50 | 10.51 | 0.137050E+09 | 103.43 | 17-DEC-10:20 | 14.50 | 10.51 |
| Annual Sum or Average | 0.239770E+11 | 0.155543E+10 | ||||||||
| Minimum of Months | 0.996796E+09 | 3609.60 | 13.20 | 10.51 | 0.119977E+09 | 93.63 | 14.50 | 10.51 | ||
| Maximum of Months | 0.288555E+10 | 4830.05 | 24.60 | 22.43 | 0.137050E+09 | 103.43 | 24.60 | 22.69 |
Report: ZoneCoolingSummaryMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.128260E+10 | 5777.99 | 15-JAN-18:02 | 16.92 | 13.14 | 0.132501E+09 | 108.11 | 15-JAN-16:49 | 16.92 | 13.14 |
| February | 0.130741E+10 | 5753.15 | 19-FEB-18:32 | 16.67 | 13.62 | 0.120348E+09 | 105.56 | 27-FEB-18:10 | 22.33 | 19.20 |
| March | 0.137512E+10 | 5726.96 | 15-MAR-14:32 | 21.80 | 16.57 | 0.129823E+09 | 105.68 | 17-MAR-17:19 | 22.73 | 19.18 |
| April | 0.186927E+10 | 5756.31 | 02-APR-20:12 | 14.80 | 12.07 | 0.134672E+09 | 104.76 | 16-APR-18:19 | 18.07 | 13.19 |
| May | 0.279256E+10 | 4706.95 | 27-MAY-18:52 | 25.00 | 22.66 | 0.128188E+09 | 95.79 | 17-MAY-20:49 | 25.00 | 22.66 |
| June | 0.282891E+10 | 4399.14 | 06-JUN-20:12 | 22.80 | 21.46 | 0.121571E+09 | 94.29 | 06-JUN-19:00 | 22.80 | 21.46 |
| July | 0.295294E+10 | 4656.66 | 12-JUL-17:32 | 23.90 | 22.65 | 0.129949E+09 | 103.73 | 12-JUL-17:40 | 23.90 | 22.65 |
| August | 0.299512E+10 | 4558.63 | 16-AUG-16:12 | 23.07 | 22.30 | 0.126038E+09 | 98.92 | 16-AUG-17:30 | 21.70 | 20.88 |
| September | 0.277305E+10 | 4853.37 | 06-SEP-20:02 | 24.60 | 22.43 | 0.128024E+09 | 104.74 | 02-SEP-17:49 | 24.60 | 22.43 |
| October | 0.282053E+10 | 5786.45 | 17-OCT-16:42 | 22.33 | 16.01 | 0.133229E+09 | 105.94 | 29-OCT-16:00 | 23.00 | 17.32 |
| November | 0.187434E+10 | 5775.24 | 21-NOV-17:01 | 19.62 | 15.14 | 0.132905E+09 | 104.57 | 26-NOV-16:00 | 19.40 | 14.76 |
| December | 0.154622E+10 | 5963.39 | 17-DEC-17:01 | 14.50 | 10.51 | 0.135008E+09 | 104.46 | 31-DEC-16:40 | 21.33 | 16.54 |
| Annual Sum or Average | 0.264181E+11 | 0.155226E+10 | ||||||||
| Minimum of Months | 0.128260E+10 | 4399.14 | 14.50 | 10.51 | 0.120348E+09 | 94.29 | 16.92 | 13.14 | ||
| Maximum of Months | 0.299512E+10 | 5963.39 | 25.00 | 22.66 | 0.135008E+09 | 108.11 | 25.00 | 22.66 |
Report: ZoneCoolingSummaryMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.532537E+09 | 5206.39 | 02-JAN-22:12 | 13.33 | 10.29 | 0.121859E+09 | 94.38 | 31-JAN-21:30 | 19.70 | 19.37 |
| February | 0.683823E+09 | 4958.46 | 25-FEB-19:42 | 19.08 | 17.52 | 0.116436E+09 | 94.64 | 23-FEB-21:10 | 19.08 | 17.52 |
| March | 0.975649E+09 | 5466.75 | 04-MAR-22:52 | 18.20 | 13.98 | 0.132574E+09 | 94.81 | 18-MAR-20:00 | 21.60 | 20.54 |
| April | 0.162296E+10 | 5542.17 | 16-APR-20:42 | 14.58 | 11.99 | 0.134934E+09 | 99.04 | 16-APR-20:10 | 14.58 | 11.99 |
| May | 0.277210E+10 | 4539.00 | 27-MAY-18:52 | 25.00 | 22.66 | 0.131149E+09 | 95.81 | 17-MAY-20:49 | 25.00 | 22.66 |
| June | 0.289383E+10 | 4195.20 | 06-JUN-20:12 | 22.80 | 21.46 | 0.125774E+09 | 92.76 | 06-JUN-21:40 | 22.80 | 20.96 |
| July | 0.297078E+10 | 4513.28 | 12-JUL-16:32 | 23.90 | 22.40 | 0.129639E+09 | 97.55 | 12-JUL-21:40 | 23.90 | 22.65 |
| August | 0.286199E+10 | 4315.15 | 16-AUG-16:12 | 23.07 | 22.30 | 0.130747E+09 | 95.45 | 16-AUG-20:30 | 20.80 | 20.74 |
| September | 0.245532E+10 | 4668.49 | 02-SEP-17:12 | 23.53 | 21.83 | 0.128788E+09 | 96.31 | 27-SEP-21:10 | 22.70 | 21.53 |
| October | 0.214391E+10 | 5476.39 | 17-OCT-15:11 | 23.73 | 16.39 | 0.133996E+09 | 94.16 | 01-OCT-20:10 | 23.73 | 16.39 |
| November | 0.102473E+10 | 5495.34 | 19-NOV-18:12 | 19.77 | 14.69 | 0.132180E+09 | 94.30 | 29-NOV-21:10 | 19.40 | 18.28 |
| December | 0.746006E+09 | 5480.46 | 01-DEC-17:12 | 20.00 | 14.89 | 0.127448E+09 | 93.90 | 11-DEC-21:10 | 21.83 | 19.89 |
| Annual Sum or Average | 0.216836E+11 | 0.154552E+10 | ||||||||
| Minimum of Months | 0.532537E+09 | 4195.20 | 13.33 | 10.29 | 0.116436E+09 | 92.76 | 14.58 | 11.99 | ||
| Maximum of Months | 0.297078E+10 | 5542.17 | 25.00 | 22.66 | 0.134934E+09 | 99.04 | 25.00 | 22.66 |
Report: ZoneCoolingSummaryMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.126904E+10 | 5415.79 | 28-JAN-20:12 | 14.67 | 12.54 | 0.132404E+09 | 103.55 | 29-JAN-16:00 | 22.00 | 16.46 |
| February | 0.128048E+10 | 5398.77 | 19-FEB-18:32 | 16.67 | 13.62 | 0.120018E+09 | 101.19 | 11-FEB-10:39 | 16.67 | 13.62 |
| March | 0.139806E+10 | 5380.13 | 15-MAR-14:32 | 21.80 | 16.57 | 0.129888E+09 | 100.69 | 17-MAR-17:19 | 22.73 | 19.18 |
| April | 0.186055E+10 | 5426.44 | 16-APR-20:42 | 14.58 | 11.99 | 0.134439E+09 | 100.29 | 09-APR-17:30 | 14.58 | 11.99 |
| May | 0.287044E+10 | 4494.43 | 13-MAY-12:52 | 25.00 | 22.66 | 0.128260E+09 | 95.16 | 17-MAY-20:49 | 22.80 | 22.08 |
| June | 0.288194E+10 | 4165.60 | 01-JUN-14:02 | 29.60 | 22.94 | 0.121596E+09 | 93.85 | 11-JUN-07:40 | 24.43 | 20.84 |
| July | 0.303865E+10 | 4315.97 | 12-JUL-15:32 | 23.53 | 21.40 | 0.129928E+09 | 98.92 | 12-JUL-17:40 | 23.90 | 22.65 |
| August | 0.301703E+10 | 4274.54 | 16-AUG-16:12 | 23.07 | 22.30 | 0.125997E+09 | 97.43 | 16-AUG-17:30 | 21.70 | 20.88 |
| September | 0.277620E+10 | 4497.07 | 06-SEP-20:02 | 24.60 | 22.43 | 0.127947E+09 | 101.09 | 02-SEP-17:49 | 24.60 | 22.43 |
| October | 0.280262E+10 | 5393.95 | 28-OCT-21:52 | 15.00 | 12.15 | 0.133111E+09 | 101.89 | 15-OCT-09:00 | 15.00 | 12.15 |
| November | 0.187131E+10 | 5432.20 | 21-NOV-17:01 | 19.62 | 15.14 | 0.132839E+09 | 100.11 | 18-NOV-10:09 | 19.62 | 15.14 |
| December | 0.149144E+10 | 5466.35 | 17-DEC-13:42 | 19.00 | 12.50 | 0.134699E+09 | 100.73 | 17-DEC-10:20 | 19.00 | 12.50 |
| Annual Sum or Average | 0.265578E+11 | 0.155113E+10 | ||||||||
| Minimum of Months | 0.126904E+10 | 4165.60 | 14.58 | 11.99 | 0.120018E+09 | 93.85 | 14.58 | 11.99 | ||
| Maximum of Months | 0.303865E+10 | 5466.35 | 29.60 | 22.94 | 0.134699E+09 | 103.55 | 24.60 | 22.65 |
Report: ZoneCoolingSummaryMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.508305E+09 | 4856.72 | 02-JAN-22:12 | 13.33 | 10.29 | 0.121230E+09 | 92.44 | 19-JAN-21:10 | 21.00 | 21.00 |
| February | 0.647708E+09 | 4509.55 | 26-FEB-19:02 | 20.42 | 18.26 | 0.115546E+09 | 91.76 | 24-FEB-21:40 | 20.42 | 18.26 |
| March | 0.985801E+09 | 5106.21 | 04-MAR-22:52 | 18.20 | 13.98 | 0.132171E+09 | 94.63 | 31-MAR-21:10 | 20.52 | 18.77 |
| April | 0.161778E+10 | 5187.65 | 16-APR-20:42 | 14.58 | 11.99 | 0.134846E+09 | 97.43 | 06-APR-20:30 | 14.58 | 11.99 |
| May | 0.285019E+10 | 4313.40 | 13-MAY-12:52 | 25.00 | 22.66 | 0.131214E+09 | 95.18 | 17-MAY-20:49 | 22.80 | 22.08 |
| June | 0.294718E+10 | 3959.20 | 01-JUN-14:02 | 29.60 | 22.94 | 0.125799E+09 | 92.43 | 06-JUN-20:10 | 22.80 | 21.52 |
| July | 0.305676E+10 | 4052.70 | 12-JUL-15:42 | 23.72 | 21.64 | 0.129620E+09 | 96.55 | 12-JUL-21:40 | 23.90 | 22.65 |
| August | 0.288405E+10 | 4025.20 | 16-AUG-16:12 | 23.07 | 22.30 | 0.130713E+09 | 94.70 | 16-AUG-20:30 | 20.80 | 20.74 |
| September | 0.245892E+10 | 4271.06 | 06-SEP-20:02 | 24.60 | 22.43 | 0.128741E+09 | 96.35 | 27-SEP-21:10 | 22.70 | 21.53 |
| October | 0.212455E+10 | 5108.83 | 17-OCT-15:11 | 23.73 | 16.39 | 0.133619E+09 | 92.69 | 03-OCT-20:00 | 23.73 | 16.39 |
| November | 0.101532E+10 | 5127.74 | 30-NOV-22:22 | 15.05 | 12.93 | 0.131646E+09 | 92.14 | 05-NOV-20:49 | 15.05 | 12.93 |
| December | 0.698700E+09 | 5109.18 | 17-DEC-17:32 | 13.00 | 9.82 | 0.126400E+09 | 93.65 | 11-DEC-21:10 | 13.00 | 9.82 |
| Annual Sum or Average | 0.217953E+11 | 0.154154E+10 | ||||||||
| Minimum of Months | 0.508305E+09 | 3959.20 | 13.00 | 9.82 | 0.115546E+09 | 91.76 | 13.00 | 9.82 | ||
| Maximum of Months | 0.305676E+10 | 5187.65 | 29.60 | 22.94 | 0.134846E+09 | 97.43 | 23.90 | 22.65 |
Report: ZoneCoolingSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.585825E+09 | 4671.88 | 28-JAN-20:12 | 14.67 | 12.54 | 0.128564E+09 | 92.82 | 31-JAN-21:30 | 19.70 | 19.37 |
| February | 0.704224E+09 | 4657.88 | 08-FEB-21:02 | 13.20 | 11.12 | 0.119205E+09 | 91.40 | 28-FEB-22:00 | 18.30 | 17.87 |
| March | 0.972143E+09 | 4666.92 | 04-MAR-22:52 | 18.20 | 13.98 | 0.134052E+09 | 93.56 | 18-MAR-20:00 | 21.60 | 20.54 |
| April | 0.140918E+10 | 4725.20 | 16-APR-20:42 | 14.58 | 11.99 | 0.133590E+09 | 96.83 | 06-APR-20:30 | 14.58 | 11.99 |
| May | 0.230007E+10 | 3778.61 | 13-MAY-12:52 | 25.00 | 22.66 | 0.131035E+09 | 92.68 | 17-MAY-20:49 | 22.80 | 22.08 |
| June | 0.235865E+10 | 3518.61 | 01-JUN-14:02 | 29.60 | 22.94 | 0.125720E+09 | 91.73 | 06-JUN-20:10 | 22.80 | 21.52 |
| July | 0.244634E+10 | 3510.79 | 12-JUL-15:42 | 23.72 | 21.64 | 0.129561E+09 | 94.86 | 12-JUL-21:40 | 23.90 | 22.65 |
| August | 0.234448E+10 | 3570.37 | 16-AUG-16:12 | 23.07 | 22.30 | 0.130615E+09 | 93.56 | 16-AUG-20:30 | 20.80 | 20.74 |
| September | 0.205723E+10 | 3846.25 | 06-SEP-20:02 | 24.60 | 22.43 | 0.128522E+09 | 96.10 | 27-SEP-21:10 | 22.70 | 21.53 |
| October | 0.181438E+10 | 4653.16 | 17-OCT-16:32 | 22.67 | 16.13 | 0.133498E+09 | 92.43 | 14-OCT-20:10 | 22.67 | 16.13 |
| November | 0.103192E+10 | 4697.45 | 30-NOV-22:22 | 15.05 | 12.93 | 0.131904E+09 | 91.71 | 29-NOV-22:49 | 15.05 | 12.93 |
| December | 0.797061E+09 | 4685.97 | 17-DEC-17:32 | 13.00 | 9.82 | 0.131523E+09 | 93.90 | 11-DEC-21:10 | 13.00 | 9.82 |
| Annual Sum or Average | 0.188215E+11 | 0.155779E+10 | ||||||||
| Minimum of Months | 0.585825E+09 | 3510.79 | 13.00 | 9.82 | 0.119205E+09 | 91.40 | 13.00 | 9.82 | ||
| Maximum of Months | 0.244634E+10 | 4725.20 | 29.60 | 22.94 | 0.134052E+09 | 96.83 | 23.90 | 22.65 |
Report: ZoneCoolingSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.585437E+09 | 4665.45 | 28-JAN-20:12 | 14.67 | 12.54 | 0.128586E+09 | 92.68 | 31-JAN-21:30 | 19.70 | 19.37 |
| February | 0.703023E+09 | 4651.10 | 08-FEB-21:02 | 13.20 | 11.12 | 0.119179E+09 | 91.31 | 28-FEB-22:00 | 18.30 | 17.87 |
| March | 0.974459E+09 | 4659.62 | 04-MAR-22:52 | 18.20 | 13.98 | 0.134101E+09 | 93.72 | 31-MAR-21:10 | 20.52 | 18.77 |
| April | 0.141245E+10 | 4717.68 | 16-APR-20:42 | 14.58 | 11.99 | 0.133605E+09 | 96.87 | 06-APR-20:30 | 14.58 | 11.99 |
| May | 0.230331E+10 | 3775.93 | 13-MAY-12:52 | 25.00 | 22.66 | 0.131036E+09 | 92.67 | 17-MAY-20:49 | 22.80 | 22.08 |
| June | 0.236090E+10 | 3516.60 | 01-JUN-14:02 | 29.60 | 22.94 | 0.125719E+09 | 91.68 | 06-JUN-20:10 | 22.80 | 21.52 |
| July | 0.244941E+10 | 3507.13 | 12-JUL-15:42 | 23.72 | 21.64 | 0.129560E+09 | 94.81 | 12-JUL-21:40 | 23.90 | 22.65 |
| August | 0.234541E+10 | 3564.62 | 16-AUG-16:12 | 23.07 | 22.30 | 0.130614E+09 | 93.53 | 16-AUG-20:30 | 20.80 | 20.74 |
| September | 0.205757E+10 | 3837.76 | 06-SEP-20:02 | 24.60 | 22.43 | 0.128520E+09 | 96.11 | 27-SEP-21:10 | 22.70 | 21.53 |
| October | 0.181421E+10 | 4646.25 | 17-OCT-16:32 | 22.67 | 16.13 | 0.133482E+09 | 92.43 | 14-OCT-20:10 | 22.67 | 16.13 |
| November | 0.103212E+10 | 4690.12 | 30-NOV-22:22 | 15.05 | 12.93 | 0.131906E+09 | 91.66 | 28-NOV-22:19 | 15.05 | 12.93 |
| December | 0.793160E+09 | 4678.67 | 17-DEC-17:32 | 13.00 | 9.82 | 0.131462E+09 | 93.88 | 11-DEC-21:10 | 13.00 | 9.82 |
| Annual Sum or Average | 0.188315E+11 | 0.155777E+10 | ||||||||
| Minimum of Months | 0.585437E+09 | 3507.13 | 13.00 | 9.82 | 0.119179E+09 | 91.31 | 13.00 | 9.82 | ||
| Maximum of Months | 0.244941E+10 | 4717.68 | 29.60 | 22.94 | 0.134101E+09 | 96.87 | 23.90 | 22.65 |
Report: ZoneCoolingSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.152295E+10 | 5002.40 | 15-JAN-18:02 | 16.92 | 13.14 | 0.134976E+09 | 103.63 | 15-JAN-16:49 | 16.92 | 13.14 |
| February | 0.141747E+10 | 4990.85 | 08-FEB-21:02 | 13.20 | 11.12 | 0.122017E+09 | 99.74 | 10-FEB-18:49 | 17.47 | 15.55 |
| March | 0.140780E+10 | 4947.17 | 14-MAR-20:12 | 14.43 | 11.80 | 0.131061E+09 | 98.70 | 17-MAR-17:19 | 22.73 | 19.18 |
| April | 0.166289E+10 | 5000.32 | 16-APR-20:42 | 14.58 | 11.99 | 0.133973E+09 | 99.79 | 09-APR-17:30 | 14.58 | 11.99 |
| May | 0.232061E+10 | 3986.73 | 13-MAY-21:52 | 23.90 | 21.88 | 0.128073E+09 | 92.66 | 17-MAY-20:49 | 22.80 | 22.08 |
| June | 0.229310E+10 | 3727.41 | 01-JUN-14:02 | 29.60 | 22.94 | 0.121515E+09 | 91.72 | 06-JUN-20:10 | 22.80 | 21.52 |
| July | 0.242855E+10 | 3788.26 | 12-JUL-15:32 | 23.53 | 21.40 | 0.129890E+09 | 95.25 | 12-JUL-17:40 | 23.90 | 22.65 |
| August | 0.247801E+10 | 3852.28 | 16-AUG-16:12 | 23.07 | 22.30 | 0.125910E+09 | 94.78 | 16-AUG-17:30 | 21.70 | 20.88 |
| September | 0.237762E+10 | 4112.45 | 06-SEP-20:02 | 24.60 | 22.43 | 0.127793E+09 | 97.74 | 02-SEP-17:49 | 24.60 | 22.43 |
| October | 0.249800E+10 | 4987.15 | 28-OCT-21:52 | 15.00 | 12.15 | 0.133133E+09 | 100.91 | 29-OCT-16:00 | 23.00 | 17.32 |
| November | 0.191622E+10 | 4997.89 | 21-NOV-17:01 | 19.62 | 15.14 | 0.133271E+09 | 100.53 | 26-NOV-18:10 | 15.38 | 13.56 |
| December | 0.171522E+10 | 5133.98 | 17-DEC-17:01 | 14.50 | 10.51 | 0.136753E+09 | 102.56 | 31-DEC-16:40 | 21.33 | 16.54 |
| Annual Sum or Average | 0.240384E+11 | 0.155836E+10 | ||||||||
| Minimum of Months | 0.140780E+10 | 3727.41 | 13.20 | 10.51 | 0.121515E+09 | 91.72 | 14.58 | 11.99 | ||
| Maximum of Months | 0.249800E+10 | 5133.98 | 29.60 | 22.94 | 0.136753E+09 | 103.63 | 24.60 | 22.65 |
Report: ZoneCoolingSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.152365E+10 | 4996.35 | 28-JAN-20:12 | 14.67 | 12.54 | 0.134974E+09 | 103.58 | 15-JAN-16:49 | 14.67 | 12.54 |
| February | 0.141715E+10 | 4984.74 | 08-FEB-21:02 | 13.20 | 11.12 | 0.122006E+09 | 99.73 | 10-FEB-18:49 | 17.47 | 15.55 |
| March | 0.141079E+10 | 4941.96 | 14-MAR-20:12 | 14.43 | 11.80 | 0.131069E+09 | 98.72 | 17-MAR-17:19 | 22.73 | 19.18 |
| April | 0.166595E+10 | 4993.12 | 16-APR-20:42 | 14.58 | 11.99 | 0.133974E+09 | 99.74 | 09-APR-17:30 | 14.58 | 11.99 |
| May | 0.232386E+10 | 3982.42 | 13-MAY-21:52 | 23.90 | 21.88 | 0.128075E+09 | 92.66 | 17-MAY-20:49 | 22.80 | 22.08 |
| June | 0.229540E+10 | 3726.33 | 01-JUN-14:02 | 29.60 | 22.94 | 0.121514E+09 | 91.68 | 06-JUN-20:10 | 22.80 | 21.52 |
| July | 0.243166E+10 | 3785.42 | 12-JUL-15:32 | 23.53 | 21.40 | 0.129889E+09 | 95.18 | 12-JUL-17:40 | 23.90 | 22.65 |
| August | 0.247892E+10 | 3847.13 | 16-AUG-16:12 | 23.07 | 22.30 | 0.125908E+09 | 94.74 | 16-AUG-17:30 | 21.70 | 20.88 |
| September | 0.237785E+10 | 4105.45 | 06-SEP-20:02 | 24.60 | 22.43 | 0.127790E+09 | 97.67 | 02-SEP-17:49 | 24.60 | 22.43 |
| October | 0.249805E+10 | 4980.69 | 28-OCT-21:52 | 15.00 | 12.15 | 0.133127E+09 | 100.79 | 29-OCT-16:00 | 23.00 | 17.32 |
| November | 0.191741E+10 | 4991.96 | 21-NOV-17:01 | 19.62 | 15.14 | 0.133274E+09 | 100.43 | 26-NOV-18:10 | 15.38 | 13.56 |
| December | 0.171205E+10 | 5127.52 | 17-DEC-17:01 | 14.50 | 10.51 | 0.136731E+09 | 102.55 | 31-DEC-16:40 | 21.33 | 16.54 |
| Annual Sum or Average | 0.240527E+11 | 0.155833E+10 | ||||||||
| Minimum of Months | 0.141079E+10 | 3726.33 | 13.20 | 10.51 | 0.121514E+09 | 91.68 | 14.58 | 11.99 | ||
| Maximum of Months | 0.249805E+10 | 5127.52 | 29.60 | 22.94 | 0.136731E+09 | 103.58 | 24.60 | 22.65 |
Report: ZoneCoolingSummaryMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.839826E+09 | 6354.23 | 29-JAN-15:42 | 23.00 | 16.34 | 0.115118E+09 | 117.04 | 15-JAN-16:49 | 23.00 | 16.34 |
| February | 0.954945E+09 | 6278.79 | 10-FEB-16:22 | 21.60 | 17.22 | 0.110261E+09 | 116.33 | 27-FEB-18:10 | 22.33 | 19.20 |
| March | 0.108820E+10 | 6391.88 | 16-MAR-16:12 | 22.53 | 14.26 | 0.120912E+09 | 117.03 | 17-MAR-17:19 | 22.73 | 19.18 |
| April | 0.177043E+10 | 6456.37 | 12-APR-16:42 | 23.30 | 17.27 | 0.133809E+09 | 118.06 | 16-APR-16:49 | 19.68 | 13.51 |
| May | 0.309608E+10 | 5270.22 | 27-MAY-18:52 | 25.00 | 22.66 | 0.128096E+09 | 103.23 | 17-MAY-20:49 | 25.00 | 22.66 |
| June | 0.321309E+10 | 4805.53 | 01-JUN-14:02 | 29.60 | 22.94 | 0.121469E+09 | 100.88 | 06-JUN-19:00 | 22.80 | 21.59 |
| July | 0.333805E+10 | 5718.72 | 12-JUL-16:22 | 23.90 | 22.27 | 0.130059E+09 | 123.04 | 12-JUL-17:30 | 23.90 | 22.65 |
| August | 0.335474E+10 | 5398.88 | 16-AUG-15:52 | 23.70 | 23.09 | 0.126097E+09 | 114.38 | 16-AUG-17:30 | 21.70 | 20.88 |
| September | 0.297276E+10 | 5764.51 | 02-SEP-16:42 | 22.47 | 21.28 | 0.128261E+09 | 121.43 | 02-SEP-17:49 | 25.08 | 22.58 |
| October | 0.291805E+10 | 6337.15 | 17-OCT-16:42 | 22.33 | 16.01 | 0.132303E+09 | 116.92 | 29-OCT-16:00 | 23.00 | 17.32 |
| November | 0.151584E+10 | 6375.12 | 26-NOV-18:02 | 15.38 | 13.56 | 0.127609E+09 | 115.17 | 26-NOV-16:00 | 15.38 | 13.56 |
| December | 0.113875E+10 | 6547.25 | 17-DEC-17:01 | 14.50 | 10.51 | 0.121749E+09 | 117.04 | 31-DEC-16:40 | 21.33 | 16.54 |
| Annual Sum or Average | 0.262008E+11 | 0.149574E+10 | ||||||||
| Minimum of Months | 0.839826E+09 | 4805.53 | 14.50 | 10.51 | 0.110261E+09 | 100.88 | 15.38 | 13.51 | ||
| Maximum of Months | 0.335474E+10 | 6547.25 | 29.60 | 23.09 | 0.133809E+09 | 123.04 | 25.08 | 22.66 |
Report: ZoneCoolingSummaryMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.325022E+09 | 5716.04 | 02-JAN-22:12 | 13.33 | 10.29 | 0.104042E+09 | 98.37 | 31-JAN-21:30 | 19.70 | 19.37 |
| February | 0.458783E+09 | 5679.95 | 27-FEB-18:22 | 21.60 | 18.99 | 0.105527E+09 | 98.44 | 23-FEB-21:10 | 21.60 | 18.99 |
| March | 0.747684E+09 | 6028.86 | 14-MAR-20:12 | 14.43 | 11.80 | 0.122970E+09 | 101.46 | 16-MAR-20:10 | 16.10 | 14.66 |
| April | 0.152019E+10 | 6209.00 | 16-APR-16:32 | 19.97 | 13.44 | 0.134550E+09 | 109.68 | 16-APR-20:10 | 15.32 | 12.31 |
| May | 0.307472E+10 | 5140.38 | 27-MAY-18:52 | 25.00 | 22.66 | 0.131085E+09 | 103.25 | 17-MAY-20:49 | 25.00 | 22.66 |
| June | 0.327906E+10 | 4653.49 | 01-JUN-14:02 | 29.60 | 22.94 | 0.125678E+09 | 96.70 | 06-JUN-21:40 | 22.80 | 20.96 |
| July | 0.335724E+10 | 5548.35 | 12-JUL-16:32 | 23.90 | 22.40 | 0.129796E+09 | 105.56 | 12-JUL-21:40 | 23.90 | 22.65 |
| August | 0.320895E+10 | 5169.67 | 16-AUG-15:52 | 23.70 | 23.09 | 0.130844E+09 | 103.88 | 16-AUG-20:30 | 20.80 | 20.74 |
| September | 0.263750E+10 | 5610.73 | 02-SEP-17:12 | 23.53 | 21.83 | 0.129118E+09 | 103.50 | 02-SEP-20:19 | 23.30 | 22.28 |
| October | 0.222142E+10 | 6080.79 | 17-OCT-16:12 | 23.33 | 16.37 | 0.132640E+09 | 100.76 | 01-OCT-20:10 | 23.33 | 16.37 |
| November | 0.766411E+09 | 6089.21 | 30-NOV-15:21 | 21.35 | 13.94 | 0.123215E+09 | 97.93 | 29-NOV-21:10 | 21.35 | 13.94 |
| December | 0.515449E+09 | 6035.65 | 01-DEC-17:12 | 20.00 | 14.89 | 0.110710E+09 | 96.80 | 11-DEC-21:10 | 21.83 | 19.89 |
| Annual Sum or Average | 0.221124E+11 | 0.148017E+10 | ||||||||
| Minimum of Months | 0.325022E+09 | 4653.49 | 13.33 | 10.29 | 0.104042E+09 | 96.70 | 15.32 | 12.31 | ||
| Maximum of Months | 0.335724E+10 | 6209.00 | 29.60 | 23.09 | 0.134550E+09 | 109.68 | 25.00 | 22.66 |
Report: ZoneCoolingSummaryMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.800747E+09 | 5787.35 | 29-JAN-15:42 | 23.00 | 16.34 | 0.114727E+09 | 114.77 | 29-JAN-16:00 | 22.00 | 16.46 |
| February | 0.921096E+09 | 5741.49 | 08-FEB-13:32 | 23.10 | 14.77 | 0.109372E+09 | 106.83 | 27-FEB-18:10 | 22.33 | 19.20 |
| March | 0.109695E+10 | 5808.00 | 16-MAR-16:12 | 22.53 | 14.26 | 0.120517E+09 | 109.21 | 17-MAR-17:19 | 22.73 | 19.18 |
| April | 0.174321E+10 | 5817.73 | 12-APR-16:42 | 23.30 | 17.27 | 0.133295E+09 | 111.97 | 01-APR-15:20 | 23.30 | 17.27 |
| May | 0.317423E+10 | 4848.49 | 13-MAY-12:52 | 25.00 | 22.66 | 0.128173E+09 | 102.13 | 19-MAY-20:10 | 23.48 | 22.69 |
| June | 0.326824E+10 | 4497.79 | 01-JUN-14:02 | 29.60 | 22.94 | 0.121512E+09 | 98.46 | 06-JUN-19:00 | 22.80 | 21.59 |
| July | 0.342983E+10 | 5136.86 | 12-JUL-15:12 | 23.17 | 20.92 | 0.130023E+09 | 114.95 | 12-JUL-17:40 | 23.90 | 22.65 |
| August | 0.337557E+10 | 4906.34 | 16-AUG-15:52 | 23.70 | 23.09 | 0.126043E+09 | 111.82 | 16-AUG-17:30 | 21.70 | 20.88 |
| September | 0.297642E+10 | 5114.22 | 02-SEP-16:42 | 22.47 | 21.28 | 0.128131E+09 | 113.85 | 02-SEP-17:49 | 25.08 | 22.58 |
| October | 0.289393E+10 | 5848.63 | 17-OCT-16:42 | 22.33 | 16.01 | 0.132083E+09 | 114.00 | 15-OCT-09:00 | 22.33 | 16.01 |
| November | 0.150170E+10 | 5837.82 | 21-NOV-12:22 | 23.25 | 15.84 | 0.127449E+09 | 106.71 | 26-NOV-16:00 | 19.40 | 14.76 |
| December | 0.108128E+10 | 5942.73 | 17-DEC-17:01 | 14.50 | 10.51 | 0.121116E+09 | 113.14 | 31-DEC-16:40 | 21.33 | 16.54 |
| Annual Sum or Average | 0.262632E+11 | 0.149244E+10 | ||||||||
| Minimum of Months | 0.800747E+09 | 4497.79 | 14.50 | 10.51 | 0.109372E+09 | 98.46 | 19.40 | 14.76 | ||
| Maximum of Months | 0.342983E+10 | 5942.73 | 29.60 | 23.09 | 0.133295E+09 | 114.95 | 25.08 | 22.69 |
Report: ZoneCoolingSummaryMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.304767E+09 | 5189.48 | 02-JAN-22:12 | 13.33 | 10.29 | 0.102059E+09 | 95.87 | 01-JAN-21:10 | 13.33 | 10.29 |
| February | 0.423466E+09 | 4869.68 | 26-FEB-19:02 | 20.42 | 18.26 | 0.103948E+09 | 94.41 | 24-FEB-21:10 | 20.42 | 18.26 |
| March | 0.761313E+09 | 5523.51 | 24-MAR-13:42 | 25.13 | 16.31 | 0.121923E+09 | 98.18 | 31-MAR-21:10 | 20.52 | 18.77 |
| April | 0.149359E+10 | 5619.40 | 16-APR-16:32 | 19.97 | 13.44 | 0.133845E+09 | 102.59 | 06-APR-20:30 | 19.97 | 13.44 |
| May | 0.315353E+10 | 4704.32 | 13-MAY-12:52 | 25.00 | 22.66 | 0.131154E+09 | 102.15 | 19-MAY-20:10 | 23.48 | 22.69 |
| June | 0.333490E+10 | 4368.51 | 01-JUN-14:02 | 29.60 | 22.94 | 0.125719E+09 | 94.96 | 06-JUN-21:40 | 22.80 | 20.96 |
| July | 0.344937E+10 | 4997.03 | 12-JUL-16:32 | 23.90 | 22.40 | 0.129759E+09 | 103.84 | 12-JUL-21:40 | 23.90 | 22.65 |
| August | 0.322971E+10 | 4680.80 | 16-AUG-15:52 | 23.70 | 23.09 | 0.130783E+09 | 102.67 | 16-AUG-20:30 | 20.80 | 20.74 |
| September | 0.264075E+10 | 4977.59 | 02-SEP-17:12 | 23.53 | 21.83 | 0.129036E+09 | 100.87 | 27-SEP-21:10 | 22.70 | 21.53 |
| October | 0.219596E+10 | 5503.15 | 17-OCT-15:11 | 23.73 | 16.39 | 0.131850E+09 | 96.76 | 16-OCT-21:10 | 23.73 | 16.39 |
| November | 0.745546E+09 | 5524.00 | 30-NOV-15:21 | 21.35 | 13.94 | 0.122202E+09 | 94.36 | 29-NOV-21:10 | 21.35 | 13.94 |
| December | 0.476412E+09 | 5502.18 | 01-DEC-17:12 | 20.00 | 14.89 | 0.109125E+09 | 96.55 | 11-DEC-21:10 | 21.83 | 19.89 |
| Annual Sum or Average | 0.222093E+11 | 0.147140E+10 | ||||||||
| Minimum of Months | 0.304767E+09 | 4368.51 | 13.33 | 10.29 | 0.102059E+09 | 94.36 | 13.33 | 10.29 | ||
| Maximum of Months | 0.344937E+10 | 5619.40 | 29.60 | 23.09 | 0.133845E+09 | 103.84 | 23.90 | 22.69 |
Report: ZoneCoolingSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.334849E+09 | 4918.60 | 02-JAN-22:12 | 13.33 | 10.29 | 0.105024E+09 | 96.85 | 01-JAN-21:10 | 13.33 | 10.29 |
| February | 0.436083E+09 | 4566.92 | 25-FEB-19:42 | 19.08 | 17.52 | 0.106474E+09 | 96.17 | 23-FEB-21:10 | 19.08 | 17.52 |
| March | 0.696467E+09 | 5146.88 | 04-MAR-22:52 | 18.20 | 13.98 | 0.123567E+09 | 99.11 | 31-MAR-21:10 | 20.52 | 18.77 |
| April | 0.129614E+10 | 5236.66 | 16-APR-16:32 | 19.97 | 13.44 | 0.133926E+09 | 103.68 | 15-APR-20:10 | 19.97 | 13.44 |
| May | 0.258889E+10 | 4286.28 | 27-MAY-18:52 | 25.00 | 22.66 | 0.131084E+09 | 100.94 | 19-MAY-20:10 | 25.00 | 22.66 |
| June | 0.272645E+10 | 3939.32 | 01-JUN-14:02 | 29.60 | 22.94 | 0.125692E+09 | 95.35 | 06-JUN-21:40 | 22.80 | 20.96 |
| July | 0.282194E+10 | 4500.03 | 12-JUL-16:32 | 23.90 | 22.40 | 0.129710E+09 | 103.80 | 12-JUL-21:40 | 23.90 | 22.65 |
| August | 0.267375E+10 | 4189.12 | 16-AUG-17:22 | 21.70 | 20.88 | 0.130770E+09 | 102.50 | 16-AUG-20:30 | 20.80 | 20.74 |
| September | 0.223264E+10 | 4525.46 | 02-SEP-17:12 | 23.53 | 21.83 | 0.128984E+09 | 102.08 | 27-SEP-21:10 | 22.70 | 21.53 |
| October | 0.186871E+10 | 5149.81 | 17-OCT-15:11 | 23.73 | 16.39 | 0.132530E+09 | 97.78 | 26-OCT-20:30 | 19.50 | 12.00 |
| November | 0.707595E+09 | 5177.20 | 19-NOV-18:12 | 19.77 | 14.69 | 0.125250E+09 | 98.18 | 29-NOV-21:10 | 19.40 | 18.28 |
| December | 0.493552E+09 | 5155.80 | 01-DEC-17:12 | 20.00 | 14.89 | 0.113091E+09 | 97.94 | 11-DEC-21:10 | 21.83 | 19.89 |
| Annual Sum or Average | 0.188771E+11 | 0.148610E+10 | ||||||||
| Minimum of Months | 0.334849E+09 | 3939.32 | 13.33 | 10.29 | 0.105024E+09 | 95.35 | 13.33 | 10.29 | ||
| Maximum of Months | 0.282194E+10 | 5236.66 | 29.60 | 22.94 | 0.133926E+09 | 103.80 | 25.00 | 22.66 |
Report: ZoneCoolingSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.333560E+09 | 4898.70 | 02-JAN-22:12 | 13.33 | 10.29 | 0.104890E+09 | 96.65 | 01-JAN-21:10 | 13.33 | 10.29 |
| February | 0.434675E+09 | 4543.21 | 25-FEB-19:42 | 19.08 | 17.52 | 0.106383E+09 | 95.76 | 23-FEB-21:10 | 19.08 | 17.52 |
| March | 0.699227E+09 | 5127.12 | 04-MAR-22:52 | 18.20 | 13.98 | 0.123533E+09 | 99.47 | 31-MAR-21:10 | 20.52 | 18.77 |
| April | 0.129842E+10 | 5219.63 | 16-APR-16:32 | 19.97 | 13.44 | 0.133936E+09 | 103.40 | 15-APR-20:10 | 19.97 | 13.44 |
| May | 0.259277E+10 | 4268.15 | 27-MAY-18:52 | 25.00 | 22.66 | 0.131084E+09 | 100.87 | 19-MAY-20:10 | 25.00 | 22.66 |
| June | 0.272920E+10 | 3928.61 | 01-JUN-14:02 | 29.60 | 22.94 | 0.125691E+09 | 95.23 | 06-JUN-21:40 | 22.80 | 20.96 |
| July | 0.282562E+10 | 4481.69 | 12-JUL-16:32 | 23.90 | 22.40 | 0.129708E+09 | 103.63 | 12-JUL-21:40 | 23.90 | 22.65 |
| August | 0.267484E+10 | 4172.76 | 16-AUG-15:52 | 23.70 | 23.09 | 0.130766E+09 | 102.41 | 16-AUG-20:30 | 20.80 | 20.74 |
| September | 0.223319E+10 | 4504.59 | 02-SEP-17:12 | 23.53 | 21.83 | 0.128979E+09 | 102.07 | 27-SEP-21:10 | 22.70 | 21.53 |
| October | 0.186847E+10 | 5131.48 | 17-OCT-15:11 | 23.73 | 16.39 | 0.132485E+09 | 97.33 | 26-OCT-20:30 | 19.50 | 12.00 |
| November | 0.708204E+09 | 5154.04 | 19-NOV-18:12 | 19.77 | 14.69 | 0.125202E+09 | 97.79 | 29-NOV-21:10 | 19.40 | 18.28 |
| December | 0.491618E+09 | 5141.62 | 01-DEC-17:12 | 20.00 | 14.89 | 0.112932E+09 | 97.90 | 11-DEC-21:10 | 21.83 | 19.89 |
| Annual Sum or Average | 0.188898E+11 | 0.148559E+10 | ||||||||
| Minimum of Months | 0.333560E+09 | 3928.61 | 13.33 | 10.29 | 0.104890E+09 | 95.23 | 13.33 | 10.29 | ||
| Maximum of Months | 0.282562E+10 | 5219.63 | 29.60 | 23.09 | 0.133936E+09 | 103.63 | 25.00 | 22.66 |
Report: ZoneCoolingSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.901870E+09 | 5427.23 | 15-JAN-16:42 | 21.28 | 14.19 | 0.120343E+09 | 113.59 | 29-JAN-16:00 | 22.00 | 16.46 |
| February | 0.965155E+09 | 5399.26 | 19-FEB-18:32 | 16.67 | 13.62 | 0.113321E+09 | 105.76 | 27-FEB-18:10 | 22.33 | 19.20 |
| March | 0.104577E+10 | 5427.95 | 15-MAR-16:32 | 21.10 | 16.15 | 0.122804E+09 | 106.97 | 17-MAR-17:19 | 22.73 | 19.18 |
| April | 0.154779E+10 | 5443.28 | 02-APR-18:12 | 16.83 | 12.81 | 0.133839E+09 | 110.95 | 01-APR-17:10 | 16.83 | 12.81 |
| May | 0.260989E+10 | 4433.58 | 27-MAY-18:52 | 25.00 | 22.66 | 0.128095E+09 | 100.92 | 19-MAY-20:10 | 25.00 | 22.66 |
| June | 0.265951E+10 | 4117.49 | 06-JUN-20:12 | 22.80 | 21.46 | 0.121485E+09 | 97.71 | 06-JUN-19:00 | 22.80 | 21.46 |
| July | 0.280231E+10 | 4634.48 | 12-JUL-15:12 | 23.17 | 20.92 | 0.130002E+09 | 111.00 | 12-JUL-17:40 | 23.90 | 22.65 |
| August | 0.282060E+10 | 4485.77 | 16-AUG-15:52 | 23.70 | 23.09 | 0.126040E+09 | 108.38 | 16-AUG-17:30 | 21.70 | 20.88 |
| September | 0.257162E+10 | 4585.43 | 02-SEP-17:52 | 25.60 | 22.81 | 0.128137E+09 | 110.52 | 02-SEP-17:49 | 25.60 | 22.81 |
| October | 0.257802E+10 | 5511.06 | 17-OCT-16:42 | 22.33 | 16.01 | 0.132707E+09 | 109.87 | 28-OCT-15:09 | 21.00 | 14.05 |
| November | 0.150287E+10 | 5481.04 | 26-NOV-18:02 | 15.38 | 13.56 | 0.130325E+09 | 108.21 | 26-NOV-16:00 | 15.38 | 13.56 |
| December | 0.116330E+10 | 5610.77 | 17-DEC-17:01 | 14.50 | 10.51 | 0.126228E+09 | 112.40 | 31-DEC-16:40 | 21.33 | 16.54 |
| Annual Sum or Average | 0.231687E+11 | 0.151332E+10 | ||||||||
| Minimum of Months | 0.901870E+09 | 4117.49 | 14.50 | 10.51 | 0.113321E+09 | 97.71 | 15.38 | 12.81 | ||
| Maximum of Months | 0.282060E+10 | 5610.77 | 25.60 | 23.09 | 0.133839E+09 | 113.59 | 25.60 | 22.81 |
Report: ZoneCoolingSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.904451E+09 | 5408.75 | 15-JAN-16:42 | 21.28 | 14.19 | 0.120317E+09 | 113.62 | 29-JAN-16:00 | 22.00 | 16.46 |
| February | 0.965699E+09 | 5381.96 | 19-FEB-18:32 | 16.67 | 13.62 | 0.113260E+09 | 105.57 | 27-FEB-18:10 | 22.33 | 19.20 |
| March | 0.105023E+10 | 5410.84 | 15-MAR-16:32 | 21.10 | 16.15 | 0.122858E+09 | 106.53 | 17-MAR-17:19 | 22.73 | 19.18 |
| April | 0.155056E+10 | 5424.86 | 02-APR-18:12 | 16.83 | 12.81 | 0.133819E+09 | 110.97 | 01-APR-17:10 | 16.83 | 12.81 |
| May | 0.261385E+10 | 4415.51 | 27-MAY-18:52 | 25.00 | 22.66 | 0.128095E+09 | 100.85 | 19-MAY-20:10 | 25.00 | 22.66 |
| June | 0.266235E+10 | 4101.16 | 06-JUN-20:12 | 22.80 | 21.46 | 0.121484E+09 | 97.59 | 06-JUN-19:00 | 22.80 | 21.46 |
| July | 0.280601E+10 | 4622.27 | 12-JUL-15:12 | 23.17 | 20.92 | 0.129999E+09 | 110.71 | 12-JUL-17:40 | 23.90 | 22.65 |
| August | 0.282152E+10 | 4470.01 | 16-AUG-15:52 | 23.70 | 23.09 | 0.126027E+09 | 108.29 | 16-AUG-17:30 | 21.70 | 20.88 |
| September | 0.257213E+10 | 4563.75 | 02-SEP-17:52 | 25.60 | 22.81 | 0.128130E+09 | 110.31 | 02-SEP-17:49 | 25.60 | 22.81 |
| October | 0.257817E+10 | 5489.16 | 17-OCT-16:42 | 22.33 | 16.01 | 0.132693E+09 | 109.99 | 28-OCT-15:09 | 21.00 | 14.05 |
| November | 0.150495E+10 | 5463.00 | 21-NOV-12:22 | 23.25 | 15.84 | 0.130306E+09 | 107.99 | 26-NOV-16:00 | 19.40 | 14.76 |
| December | 0.116180E+10 | 5591.01 | 17-DEC-17:01 | 14.50 | 10.51 | 0.126159E+09 | 112.36 | 31-DEC-16:40 | 21.33 | 16.54 |
| Annual Sum or Average | 0.231917E+11 | 0.151315E+10 | ||||||||
| Minimum of Months | 0.904451E+09 | 4101.16 | 14.50 | 10.51 | 0.113260E+09 | 97.59 | 16.83 | 12.81 | ||
| Maximum of Months | 0.282152E+10 | 5591.01 | 25.60 | 23.09 | 0.133819E+09 | 113.62 | 25.60 | 22.81 |
Report: ZoneCoolingSummaryMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 17.00 | 16.69 | 0.206226E+09 | 168.08 | 01-JAN-21:19 | 19.00 | 17.48 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 18.20 | 18.20 | 0.206917E+09 | 167.87 | 28-FEB-21:10 | 19.30 | 18.37 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 17.62 | 17.16 | 0.240636E+09 | 172.87 | 17-MAR-20:10 | 21.10 | 18.46 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 | 19.79 | 0.270144E+09 | 174.87 | 16-APR-20:10 | 15.32 | 12.31 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 | 19.11 | 0.289405E+09 | 172.30 | 03-MAY-20:10 | 28.30 | 22.17 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 | 21.40 | 0.282490E+09 | 174.50 | 13-JUN-20:10 | 30.03 | 21.76 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 | 23.10 | 0.293617E+09 | 184.01 | 12-JUL-20:10 | 23.90 | 22.44 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 | 23.55 | 0.292552E+09 | 176.46 | 16-AUG-20:10 | 21.07 | 20.97 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 | 24.22 | 0.280303E+09 | 175.34 | 09-SEP-20:10 | 34.67 | 27.13 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 | 20.64 | 0.283097E+09 | 171.91 | 26-OCT-20:10 | 19.83 | 11.96 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 | 21.01 | 0.248132E+09 | 169.71 | 04-NOV-20:10 | 21.18 | 19.56 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 14.12 | 12.36 | 0.222759E+09 | 165.94 | 15-DEC-22:30 | 22.50 | 21.42 |
| Annual Sum or Average | 0.00 | 0.311628E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 14.12 | 12.36 | 0.206226E+09 | 165.94 | 15.32 | 11.96 | ||
| Maximum of Months | 0.00 | 0.00 | 25.13 | 24.22 | 0.293617E+09 | 184.01 | 34.67 | 27.13 |
Report: ZoneCoolingSummaryMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 17.00 | 16.69 | 0.229796E+09 | 180.05 | 01-JAN-22:40 | 18.33 | 17.29 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 18.20 | 18.20 | 0.216531E+09 | 175.20 | 28-FEB-23:30 | 18.00 | 17.68 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 17.62 | 17.16 | 0.250355E+09 | 174.24 | 30-MAR-21:40 | 18.80 | 18.47 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 | 19.79 | 0.281857E+09 | 193.99 | 28-APR-17:10 | 29.80 | 24.19 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 | 19.11 | 0.334090E+09 | 215.66 | 07-MAY-17:10 | 33.22 | 23.18 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 | 21.40 | 0.331234E+09 | 216.77 | 11-JUN-17:10 | 33.12 | 21.85 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 | 23.10 | 0.347736E+09 | 235.63 | 22-JUL-17:10 | 34.63 | 26.60 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 | 23.55 | 0.348199E+09 | 233.55 | 30-AUG-17:10 | 34.67 | 23.11 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 | 24.22 | 0.330122E+09 | 244.87 | 09-SEP-17:10 | 36.18 | 26.62 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 | 20.64 | 0.330058E+09 | 215.05 | 05-OCT-17:10 | 32.83 | 23.08 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 | 21.01 | 0.277600E+09 | 188.62 | 05-NOV-21:40 | 22.17 | 18.77 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 14.12 | 12.36 | 0.254370E+09 | 187.39 | 16-DEC-23:10 | 22.00 | 22.00 |
| Annual Sum or Average | 0.00 | 0.353195E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 14.12 | 12.36 | 0.216531E+09 | 174.24 | 18.00 | 17.29 | ||
| Maximum of Months | 0.00 | 0.00 | 25.13 | 24.22 | 0.348199E+09 | 244.87 | 36.18 | 26.62 |
Report: ZoneCoolingSummaryMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 17.00 | 16.69 | 0.257213E+09 | 163.92 | 31-JAN-21:00 | 19.40 | 19.40 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 18.20 | 18.20 | 0.241993E+09 | 165.30 | 27-FEB-21:10 | 19.30 | 18.52 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 17.62 | 17.16 | 0.271897E+09 | 166.26 | 17-MAR-20:19 | 21.10 | 18.46 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 | 19.79 | 0.278704E+09 | 168.10 | 07-APR-20:10 | 15.50 | 12.59 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 | 19.11 | 0.283970E+09 | 161.27 | 17-MAY-21:40 | 23.53 | 22.30 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 | 21.40 | 0.275553E+09 | 161.44 | 11-JUN-20:10 | 28.72 | 21.28 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 | 23.10 | 0.285060E+09 | 164.81 | 12-JUL-20:40 | 23.90 | 22.57 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 | 23.55 | 0.284968E+09 | 162.36 | 16-AUG-21:10 | 20.47 | 20.47 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 | 24.22 | 0.276357E+09 | 164.61 | 27-SEP-21:40 | 22.70 | 21.28 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 | 20.64 | 0.285306E+09 | 164.28 | 26-OCT-20:00 | 19.00 | 12.03 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 | 21.01 | 0.272679E+09 | 164.18 | 04-NOV-20:10 | 21.18 | 19.56 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 14.12 | 12.36 | 0.266086E+09 | 163.52 | 16-DEC-21:00 | 22.00 | 22.00 |
| Annual Sum or Average | 0.00 | 0.327979E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 14.12 | 12.36 | 0.241993E+09 | 161.27 | 15.50 | 12.03 | ||
| Maximum of Months | 0.00 | 0.00 | 25.13 | 24.22 | 0.285306E+09 | 168.10 | 28.72 | 22.57 |
Report: ZoneHeatingSummaryMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 86907.05 | 35.22 | 19-JAN-11:07 | 24.92 |
| February | 156050.41 | 27.90 | 24-FEB-11:37 | 24.40 |
| March | 725981.27 | 53.82 | 26-MAR-15:55 | 26.10 |
| April | 1158627.23 | 62.57 | 24-APR-11:57 | 27.20 |
| May | 1269103.47 | 54.82 | 14-MAY-13:05 | 26.05 |
| June | 591361.42 | 55.11 | 07-JUN-09:10 | 26.78 |
| July | 324439.16 | 54.77 | 18-JUL-06:55 | 26.10 |
| August | 407174.42 | 53.37 | 27-AUG-07:47 | 26.50 |
| September | 486479.14 | 48.14 | 05-SEP-08:47 | 25.75 |
| October | 321629.01 | 51.04 | 12-OCT-09:07 | 26.33 |
| November | 333924.55 | 55.83 | 29-NOV-12:57 | 26.60 |
| December | 144847.45 | 45.18 | 14-DEC-11:47 | 25.67 |
| Annual Sum or Average | 6006524.58 | |||
| Minimum of Months | 86907.05 | 27.90 | 24.40 | |
| Maximum of Months | 1269103.47 | 62.57 | 27.20 |
Report: ZoneHeatingSummaryMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 526477.87 | 43.19 | 17-JAN-13:15 | 25.00 |
| February | 1357241.00 | 51.11 | 26-FEB-11:35 | 25.73 |
| March | 1828264.42 | 53.77 | 26-MAR-15:55 | 26.10 |
| April | 1411774.72 | 63.19 | 24-APR-11:57 | 27.20 |
| May | 1190259.01 | 54.64 | 14-MAY-13:05 | 26.05 |
| June | 487490.30 | 55.22 | 07-JUN-09:10 | 26.78 |
| July | 301291.43 | 53.18 | 18-JUL-06:55 | 26.10 |
| August | 422893.88 | 54.38 | 27-AUG-07:47 | 26.50 |
| September | 580823.40 | 46.75 | 01-SEP-07:07 | 25.97 |
| October | 502218.30 | 53.09 | 12-OCT-09:07 | 26.33 |
| November | 698943.28 | 55.28 | 29-NOV-12:57 | 26.60 |
| December | 517894.00 | 50.15 | 10-DEC-10:45 | 25.67 |
| Annual Sum or Average | 9825571.62 | |||
| Minimum of Months | 301291.43 | 43.19 | 25.00 | |
| Maximum of Months | 1828264.42 | 63.19 | 27.20 |
Report: ZoneHeatingSummaryMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 58386312.18 | 351.56 | 16-JAN-15:00 | 27.00 |
| February | 75961997.75 | 3685.63 | 06-FEB-07:01 | 3.90 |
| March | 0.148088E+09 | 2050.12 | 13-MAR-06:01 | 5.92 |
| April | 0.272492E+09 | 666.72 | 28-APR-16:12 | 31.83 |
| May | 0.561509E+09 | 706.58 | 25-MAY-16:12 | 32.80 |
| June | 0.565544E+09 | 719.05 | 28-JUN-16:12 | 33.13 |
| July | 0.563234E+09 | 773.26 | 21-JUL-16:13 | 34.80 |
| August | 0.464537E+09 | 781.17 | 30-AUG-16:13 | 35.83 |
| September | 0.370176E+09 | 619.72 | 06-SEP-16:13 | 31.93 |
| October | 0.287905E+09 | 635.92 | 05-OCT-16:13 | 32.33 |
| November | 0.121854E+09 | 499.26 | 02-NOV-16:12 | 28.43 |
| December | 90640592.53 | 464.88 | 15-DEC-17:12 | 27.33 |
| Annual Sum or Average | 0.358033E+10 | |||
| Minimum of Months | 58386312.18 | 351.56 | 3.90 | |
| Maximum of Months | 0.565544E+09 | 3685.63 | 35.83 |
Report: ZoneHeatingSummaryMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 446239.25 | 42.23 | 19-JAN-11:27 | 25.35 |
| February | 1190041.96 | 51.39 | 21-FEB-13:55 | 26.10 |
| March | 1483029.62 | 53.95 | 26-MAR-15:55 | 26.10 |
| April | 1049475.16 | 62.01 | 24-APR-12:10 | 27.20 |
| May | 963791.25 | 51.81 | 14-MAY-13:20 | 26.50 |
| June | 374734.70 | 86.75 | 01-JUN-14:07 | 29.60 |
| July | 282638.36 | 50.47 | 12-JUL-06:57 | 26.10 |
| August | 398425.52 | 56.07 | 27-AUG-07:47 | 26.50 |
| September | 571925.86 | 48.39 | 01-SEP-07:07 | 25.97 |
| October | 486523.03 | 53.70 | 12-OCT-09:07 | 26.33 |
| November | 533630.48 | 56.84 | 29-NOV-12:57 | 26.60 |
| December | 434801.69 | 46.19 | 09-DEC-11:00 | 26.00 |
| Annual Sum or Average | 8215256.88 | |||
| Minimum of Months | 282638.36 | 42.23 | 25.35 | |
| Maximum of Months | 1483029.62 | 86.75 | 29.60 |
Report: ZoneHeatingSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 465800.52 | 42.75 | 19-JAN-11:27 | 25.35 |
| February | 1172434.81 | 53.09 | 21-FEB-13:55 | 26.10 |
| March | 1602676.27 | 53.07 | 26-MAR-15:55 | 26.10 |
| April | 1400993.51 | 61.97 | 24-APR-12:10 | 27.20 |
| May | 1196048.22 | 51.82 | 14-MAY-13:20 | 26.50 |
| June | 642509.99 | 89.46 | 01-JUN-14:07 | 29.60 |
| July | 366948.15 | 51.87 | 12-JUL-06:57 | 26.10 |
| August | 582562.74 | 54.60 | 27-AUG-07:47 | 26.50 |
| September | 765944.63 | 51.90 | 01-SEP-07:20 | 26.43 |
| October | 618743.42 | 53.72 | 10-OCT-09:17 | 26.40 |
| November | 720136.45 | 55.84 | 29-NOV-12:57 | 26.60 |
| December | 498621.44 | 46.89 | 09-DEC-11:00 | 26.00 |
| Annual Sum or Average | 10033420.16 | |||
| Minimum of Months | 366948.15 | 42.75 | 25.35 | |
| Maximum of Months | 1602676.27 | 89.46 | 29.60 |
Report: ZoneHeatingSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 463756.83 | 42.87 | 19-JAN-11:27 | 25.35 |
| February | 1165395.66 | 53.17 | 21-FEB-13:55 | 26.10 |
| March | 1586043.38 | 53.03 | 26-MAR-15:55 | 26.10 |
| April | 1386058.15 | 61.96 | 24-APR-12:10 | 27.20 |
| May | 1192154.38 | 51.80 | 14-MAY-13:20 | 26.50 |
| June | 643257.90 | 89.57 | 01-JUN-14:07 | 29.60 |
| July | 366687.96 | 51.84 | 12-JUL-06:57 | 26.10 |
| August | 580077.88 | 54.57 | 27-AUG-07:47 | 26.50 |
| September | 762910.90 | 51.89 | 01-SEP-07:20 | 26.43 |
| October | 609372.87 | 53.79 | 10-OCT-09:17 | 26.40 |
| November | 706726.31 | 55.81 | 29-NOV-12:57 | 26.60 |
| December | 497394.70 | 46.87 | 09-DEC-11:00 | 26.00 |
| Annual Sum or Average | 9959836.92 | |||
| Minimum of Months | 366687.96 | 42.87 | 25.35 | |
| Maximum of Months | 1586043.38 | 89.57 | 29.60 |
Report: ZoneHeatingSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 75149.34 | 36.72 | 17-JAN-13:17 | 25.00 |
| February | 174239.59 | 50.80 | 01-FEB-14:47 | 26.23 |
| March | 627755.96 | 49.71 | 27-MAR-11:07 | 26.18 |
| April | 1099781.07 | 61.40 | 24-APR-12:10 | 27.20 |
| May | 1255375.29 | 51.80 | 16-MAY-07:10 | 26.38 |
| June | 735151.12 | 89.16 | 01-JUN-14:20 | 29.80 |
| July | 390781.26 | 51.32 | 18-JUL-07:10 | 26.47 |
| August | 528751.31 | 56.55 | 27-AUG-07:47 | 26.50 |
| September | 661514.89 | 51.32 | 01-SEP-07:20 | 26.43 |
| October | 292201.17 | 54.49 | 12-OCT-09:07 | 26.33 |
| November | 268750.46 | 51.06 | 07-NOV-09:57 | 26.10 |
| December | 105137.27 | 43.96 | 10-DEC-10:47 | 25.67 |
| Annual Sum or Average | 6214588.73 | |||
| Minimum of Months | 75149.34 | 36.72 | 25.00 | |
| Maximum of Months | 1255375.29 | 89.16 | 29.80 |
Report: ZoneHeatingSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 80493.70 | 36.49 | 17-JAN-13:17 | 25.00 |
| February | 173227.64 | 50.56 | 01-FEB-14:47 | 26.23 |
| March | 589553.01 | 50.26 | 27-MAR-11:07 | 26.18 |
| April | 1021155.71 | 62.07 | 24-APR-11:57 | 27.20 |
| May | 1062277.44 | 51.74 | 16-MAY-07:10 | 26.38 |
| June | 577227.09 | 88.75 | 01-JUN-14:20 | 29.80 |
| July | 338717.85 | 51.45 | 12-JUL-06:57 | 26.10 |
| August | 414631.58 | 55.99 | 27-AUG-07:47 | 26.50 |
| September | 498445.70 | 48.90 | 01-SEP-07:07 | 25.97 |
| October | 272829.28 | 54.05 | 12-OCT-09:07 | 26.33 |
| November | 255487.18 | 50.47 | 07-NOV-09:57 | 26.10 |
| December | 97798.77 | 43.67 | 10-DEC-10:47 | 25.67 |
| Annual Sum or Average | 5381844.94 | |||
| Minimum of Months | 80493.70 | 36.49 | 25.00 | |
| Maximum of Months | 1062277.44 | 88.75 | 29.80 |
Report: ZoneHeatingSummaryMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 65015.83 | 41.79 | 17-JAN-13:15 | 25.00 |
| February | 88789.25 | 35.47 | 11-FEB-12:05 | 24.50 |
| March | 277687.61 | 46.72 | 31-MAR-11:55 | 25.50 |
| April | 511128.93 | 60.04 | 24-APR-11:57 | 27.20 |
| May | 907585.49 | 55.24 | 14-MAY-13:05 | 26.05 |
| June | 464835.68 | 53.55 | 10-JUN-07:25 | 26.10 |
| July | 301051.94 | 55.81 | 15-JUL-06:55 | 26.10 |
| August | 628129.74 | 53.84 | 01-AUG-06:55 | 26.10 |
| September | 804104.05 | 53.06 | 01-SEP-07:05 | 25.97 |
| October | 377761.81 | 48.99 | 22-OCT-09:07 | 26.00 |
| November | 339036.58 | 54.13 | 29-NOV-12:57 | 26.60 |
| December | 161604.40 | 43.27 | 14-DEC-11:47 | 25.67 |
| Annual Sum or Average | 4926731.31 | |||
| Minimum of Months | 65015.83 | 35.47 | 24.50 | |
| Maximum of Months | 907585.49 | 60.04 | 27.20 |
Report: ZoneHeatingSummaryMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 299265.20 | 41.57 | 02-JAN-11:45 | 24.83 |
| February | 487020.33 | 51.79 | 26-FEB-11:35 | 25.73 |
| March | 642406.69 | 54.94 | 26-MAR-15:55 | 26.10 |
| April | 544578.65 | 61.96 | 24-APR-11:57 | 27.20 |
| May | 821720.32 | 55.15 | 14-MAY-13:05 | 26.05 |
| June | 362795.75 | 32.53 | 01-JUN-13:40 | 27.20 |
| July | 285829.24 | 55.29 | 18-JUL-06:55 | 26.10 |
| August | 624121.57 | 52.86 | 01-AUG-06:55 | 26.10 |
| September | 917673.17 | 52.42 | 01-SEP-07:05 | 25.97 |
| October | 1009444.01 | 51.42 | 12-OCT-09:07 | 26.33 |
| November | 892035.55 | 52.69 | 28-NOV-10:35 | 25.87 |
| December | 606634.35 | 50.24 | 10-DEC-10:45 | 25.67 |
| Annual Sum or Average | 7493524.83 | |||
| Minimum of Months | 285829.24 | 32.53 | 24.83 | |
| Maximum of Months | 1009444.01 | 61.96 | 27.20 |
Report: ZoneHeatingSummaryMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 49769.28 | 32.42 | 02-JAN-11:05 | 24.17 |
| February | 82733.70 | 20.94 | 01-FEB-14:25 | 25.50 |
| March | 220312.24 | 47.77 | 27-MAR-11:07 | 26.18 |
| April | 373094.53 | 61.65 | 24-APR-11:57 | 27.20 |
| May | 628125.91 | 54.16 | 14-MAY-13:05 | 26.05 |
| June | 318682.06 | 42.85 | 08-JUN-08:17 | 25.73 |
| July | 264459.79 | 53.97 | 18-JUL-06:55 | 26.10 |
| August | 538387.90 | 54.17 | 27-AUG-07:47 | 26.50 |
| September | 765736.43 | 38.73 | 23-SEP-08:07 | 25.27 |
| October | 338178.19 | 51.25 | 12-OCT-09:07 | 26.33 |
| November | 233072.49 | 42.60 | 02-NOV-08:57 | 25.50 |
| December | 132344.47 | 43.65 | 14-DEC-11:47 | 25.67 |
| Annual Sum or Average | 3944896.99 | |||
| Minimum of Months | 49769.28 | 20.94 | 24.17 | |
| Maximum of Months | 765736.43 | 61.65 | 27.20 |
Report: ZoneHeatingSummaryMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 243972.51 | 41.54 | 19-JAN-11:27 | 25.35 |
| February | 362339.12 | 47.24 | 21-FEB-13:57 | 26.10 |
| March | 358606.39 | 54.84 | 26-MAR-15:55 | 26.10 |
| April | 368664.49 | 63.04 | 24-APR-11:57 | 27.20 |
| May | 591316.73 | 48.46 | 16-MAY-06:57 | 26.10 |
| June | 289333.26 | 54.92 | 07-JUN-08:57 | 26.70 |
| July | 266389.35 | 52.41 | 18-JUL-06:55 | 26.10 |
| August | 586716.17 | 54.48 | 27-AUG-07:47 | 26.50 |
| September | 865580.00 | 45.59 | 23-SEP-08:27 | 25.80 |
| October | 746076.94 | 52.83 | 12-OCT-09:07 | 26.33 |
| November | 591516.61 | 54.62 | 29-NOV-12:57 | 26.60 |
| December | 451953.11 | 45.00 | 02-DEC-13:15 | 25.00 |
| Annual Sum or Average | 5722464.67 | |||
| Minimum of Months | 243972.51 | 41.54 | 25.00 | |
| Maximum of Months | 865580.00 | 63.04 | 27.20 |
Report: ZoneHeatingSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 283078.36 | 41.43 | 19-JAN-11:27 | 25.35 |
| February | 536705.02 | 48.09 | 21-FEB-13:57 | 26.10 |
| March | 693933.45 | 51.45 | 24-MAR-14:05 | 25.60 |
| April | 686026.51 | 45.98 | 22-APR-09:37 | 25.87 |
| May | 979586.69 | 48.01 | 16-MAY-06:57 | 26.10 |
| June | 557772.60 | 87.05 | 01-JUN-14:07 | 29.60 |
| July | 335702.43 | 48.38 | 12-JUL-06:57 | 26.10 |
| August | 707803.15 | 54.75 | 27-AUG-07:47 | 26.50 |
| September | 1091912.49 | 44.51 | 23-SEP-08:27 | 25.80 |
| October | 1136990.97 | 52.24 | 10-OCT-09:17 | 26.40 |
| November | 899002.40 | 55.88 | 29-NOV-12:57 | 26.60 |
| December | 473858.22 | 48.00 | 10-DEC-10:45 | 25.67 |
| Annual Sum or Average | 8382372.29 | |||
| Minimum of Months | 283078.36 | 41.43 | 25.35 | |
| Maximum of Months | 1136990.97 | 87.05 | 29.60 |
Report: ZoneHeatingSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 280880.51 | 41.62 | 01-JAN-12:45 | 24.83 |
| February | 531244.62 | 48.14 | 21-FEB-13:57 | 26.10 |
| March | 685118.37 | 51.74 | 24-MAR-14:05 | 25.60 |
| April | 674647.48 | 46.16 | 22-APR-09:37 | 25.87 |
| May | 977938.82 | 48.06 | 16-MAY-06:57 | 26.10 |
| June | 557145.83 | 87.17 | 01-JUN-14:07 | 29.60 |
| July | 333574.74 | 48.42 | 12-JUL-06:57 | 26.10 |
| August | 708511.05 | 54.79 | 27-AUG-07:47 | 26.50 |
| September | 1091329.68 | 44.59 | 23-SEP-08:27 | 25.80 |
| October | 1128512.58 | 52.41 | 10-OCT-09:17 | 26.40 |
| November | 889828.44 | 55.94 | 29-NOV-12:57 | 26.60 |
| December | 463775.42 | 47.84 | 10-DEC-10:45 | 25.67 |
| Annual Sum or Average | 8322507.54 | |||
| Minimum of Months | 280880.51 | 41.62 | 24.83 | |
| Maximum of Months | 1128512.58 | 87.17 | 29.60 |
Report: ZoneHeatingSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 47379.71 | 34.61 | 17-JAN-13:17 | 25.00 |
| February | 88731.09 | 31.05 | 02-FEB-10:37 | 24.57 |
| March | 304552.91 | 54.16 | 26-MAR-15:55 | 26.10 |
| April | 557351.81 | 62.34 | 24-APR-11:57 | 27.20 |
| May | 997242.83 | 45.51 | 15-MAY-07:27 | 25.85 |
| June | 576015.16 | 61.40 | 01-JUN-14:00 | 29.40 |
| July | 364002.19 | 53.60 | 18-JUL-06:55 | 26.10 |
| August | 676601.33 | 54.67 | 27-AUG-07:47 | 26.50 |
| September | 902267.25 | 39.25 | 23-SEP-08:07 | 25.27 |
| October | 396434.65 | 52.81 | 12-OCT-09:07 | 26.33 |
| November | 264614.93 | 49.40 | 07-NOV-09:57 | 26.10 |
| December | 110028.76 | 37.93 | 11-DEC-11:17 | 25.00 |
| Annual Sum or Average | 5285222.61 | |||
| Minimum of Months | 47379.71 | 31.05 | 24.57 | |
| Maximum of Months | 997242.83 | 62.34 | 29.40 |
Report: ZoneHeatingSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 47353.84 | 34.66 | 17-JAN-13:17 | 25.00 |
| February | 88414.20 | 31.11 | 02-FEB-10:37 | 24.57 |
| March | 297289.28 | 54.23 | 26-MAR-15:55 | 26.10 |
| April | 539733.08 | 62.34 | 24-APR-11:57 | 27.20 |
| May | 998151.53 | 45.58 | 15-MAY-07:27 | 25.85 |
| June | 576197.86 | 61.31 | 01-JUN-14:00 | 29.40 |
| July | 364497.61 | 53.56 | 18-JUL-06:55 | 26.10 |
| August | 676784.31 | 54.70 | 27-AUG-07:47 | 26.50 |
| September | 902667.40 | 39.32 | 23-SEP-08:07 | 25.27 |
| October | 389800.66 | 52.86 | 12-OCT-09:07 | 26.33 |
| November | 262132.08 | 49.45 | 07-NOV-09:57 | 26.10 |
| December | 110394.75 | 37.96 | 11-DEC-11:17 | 25.00 |
| Annual Sum or Average | 5253416.60 | |||
| Minimum of Months | 47353.84 | 31.11 | 24.57 | |
| Maximum of Months | 998151.53 | 62.34 | 29.40 |
Report: ZoneHeatingSummaryMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 90805184.18 | 782.93 | 05-JAN-06:00 | 0.00 |
| February | 74607979.86 | 1276.83 | 05-FEB-07:00 | -3.4 |
| March | 62201648.18 | 621.96 | 12-MAR-07:00 | 6.60 |
| April | 500914.76 | 51.98 | 21-APR-10:05 | 25.68 |
| May | 1116852.00 | 57.37 | 14-MAY-13:05 | 26.05 |
| June | 509187.18 | 93.47 | 01-JUN-14:05 | 29.60 |
| July | 321285.62 | 54.99 | 18-JUL-06:55 | 26.10 |
| August | 730174.96 | 55.44 | 01-AUG-06:55 | 26.10 |
| September | 962390.45 | 54.72 | 01-SEP-07:05 | 25.97 |
| October | 449587.65 | 53.26 | 14-OCT-19:55 | 26.00 |
| November | 496256.46 | 49.51 | 10-NOV-11:25 | 25.80 |
| December | 73550546.12 | 921.38 | 21-DEC-07:00 | 0.00 |
| Annual Sum or Average | 0.306252E+09 | |||
| Minimum of Months | 321285.62 | 49.51 | -3.4 | |
| Maximum of Months | 90805184.18 | 1276.83 | 29.60 |
Report: ZoneHeatingSummaryMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.276737E+09 | 1084.16 | 05-JAN-06:00 | 0.00 |
| February | 0.163634E+09 | 1445.36 | 05-FEB-07:00 | -3.4 |
| March | 90437245.68 | 654.86 | 12-MAR-07:00 | 6.60 |
| April | 547198.00 | 60.31 | 24-APR-11:57 | 27.20 |
| May | 882275.35 | 59.10 | 14-MAY-13:05 | 26.05 |
| June | 344055.30 | 54.16 | 10-JUN-07:25 | 26.10 |
| July | 291232.38 | 55.70 | 15-JUL-06:55 | 26.10 |
| August | 744078.70 | 54.68 | 01-AUG-06:55 | 26.10 |
| September | 1022557.78 | 54.63 | 01-SEP-07:05 | 25.97 |
| October | 1007064.68 | 51.95 | 31-OCT-11:45 | 25.67 |
| November | 6248229.64 | 262.63 | 16-NOV-06:00 | 9.40 |
| December | 0.171636E+09 | 1136.97 | 21-DEC-07:00 | 0.00 |
| Annual Sum or Average | 0.713531E+09 | |||
| Minimum of Months | 291232.38 | 51.95 | -3.4 | |
| Maximum of Months | 0.276737E+09 | 1445.36 | 27.20 |
Report: ZoneHeatingSummaryMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 86846476.61 | 801.89 | 05-JAN-06:00 | 0.00 |
| February | 70922392.57 | 1291.52 | 05-FEB-07:00 | -3.4 |
| March | 58849975.72 | 621.54 | 12-MAR-06:40 | 6.80 |
| April | 359605.57 | 60.17 | 24-APR-11:57 | 27.20 |
| May | 651248.31 | 47.59 | 16-MAY-06:57 | 26.10 |
| June | 309471.38 | 62.21 | 01-JUN-14:00 | 29.40 |
| July | 284144.53 | 55.22 | 18-JUL-06:55 | 26.10 |
| August | 600976.76 | 54.75 | 27-AUG-07:47 | 26.50 |
| September | 847710.14 | 52.31 | 01-SEP-07:05 | 25.97 |
| October | 381905.27 | 50.12 | 12-OCT-09:07 | 26.33 |
| November | 508216.39 | 61.64 | 16-NOV-06:00 | 9.40 |
| December | 75674804.72 | 953.32 | 21-DEC-07:00 | 0.00 |
| Annual Sum or Average | 0.296237E+09 | |||
| Minimum of Months | 284144.53 | 47.59 | -3.4 | |
| Maximum of Months | 86846476.61 | 1291.52 | 29.40 |
Report: ZoneHeatingSummaryMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.260255E+09 | 1107.68 | 05-JAN-06:00 | 0.00 |
| February | 0.152300E+09 | 1460.08 | 05-FEB-07:00 | -3.4 |
| March | 85500220.11 | 660.08 | 09-MAR-06:50 | 1.10 |
| April | 319856.12 | 61.87 | 24-APR-11:57 | 27.20 |
| May | 598736.01 | 48.51 | 16-MAY-06:57 | 26.10 |
| June | 288464.18 | 62.47 | 01-JUN-14:00 | 29.40 |
| July | 260826.32 | 53.89 | 18-JUL-06:55 | 26.10 |
| August | 600682.72 | 54.99 | 27-AUG-07:47 | 26.50 |
| September | 909957.90 | 51.68 | 01-SEP-07:05 | 25.97 |
| October | 714841.97 | 52.15 | 04-OCT-08:07 | 26.17 |
| November | 5499242.42 | 277.27 | 16-NOV-06:00 | 9.40 |
| December | 0.173169E+09 | 1162.30 | 21-DEC-07:00 | 0.00 |
| Annual Sum or Average | 0.680418E+09 | |||
| Minimum of Months | 260826.32 | 48.51 | -3.4 | |
| Maximum of Months | 0.260255E+09 | 1460.08 | 29.40 |
Report: ZoneHeatingSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.101450E+09 | 662.05 | 05-JAN-06:00 | 0.00 |
| February | 69093766.75 | 850.06 | 05-FEB-07:00 | -3.4 |
| March | 27033748.80 | 326.56 | 12-MAR-07:02 | 6.97 |
| April | 560758.53 | 64.62 | 24-APR-11:57 | 27.20 |
| May | 940982.12 | 53.93 | 14-MAY-13:05 | 26.05 |
| June | 358741.62 | 85.90 | 01-JUN-14:07 | 29.60 |
| July | 306043.13 | 53.73 | 18-JUL-06:55 | 26.10 |
| August | 704501.19 | 55.95 | 27-AUG-07:47 | 26.50 |
| September | 1008293.54 | 51.69 | 01-SEP-07:20 | 26.43 |
| October | 1077753.33 | 54.62 | 12-OCT-09:07 | 26.33 |
| November | 1351701.13 | 58.11 | 29-NOV-12:57 | 26.60 |
| December | 60408885.24 | 712.15 | 21-DEC-06:00 | 1.00 |
| Annual Sum or Average | 0.264296E+09 | |||
| Minimum of Months | 306043.13 | 51.69 | -3.4 | |
| Maximum of Months | 0.101450E+09 | 850.06 | 29.60 |
Report: ZoneHeatingSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.102040E+09 | 663.18 | 05-JAN-06:00 | 0.00 |
| February | 69269642.75 | 850.94 | 05-FEB-07:00 | -3.4 |
| March | 26964205.76 | 325.92 | 12-MAR-07:02 | 6.97 |
| April | 542913.38 | 64.68 | 24-APR-11:57 | 27.20 |
| May | 918357.31 | 50.95 | 16-MAY-07:10 | 26.38 |
| June | 359001.96 | 86.01 | 01-JUN-14:07 | 29.60 |
| July | 297664.04 | 53.62 | 18-JUL-06:55 | 26.10 |
| August | 702685.98 | 56.05 | 27-AUG-07:47 | 26.50 |
| September | 1005810.02 | 51.68 | 01-SEP-07:20 | 26.43 |
| October | 1067054.32 | 54.73 | 12-OCT-09:07 | 26.33 |
| November | 1310160.16 | 58.24 | 29-NOV-12:57 | 26.60 |
| December | 60840920.05 | 714.26 | 21-DEC-06:00 | 1.00 |
| Annual Sum or Average | 0.265318E+09 | |||
| Minimum of Months | 297664.04 | 50.95 | -3.4 | |
| Maximum of Months | 0.102040E+09 | 850.94 | 29.60 |
Report: ZoneHeatingSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 10412715.36 | 331.38 | 05-JAN-06:00 | 0.00 |
| February | 17860254.32 | 650.38 | 05-FEB-07:00 | -3.4 |
| March | 12552906.14 | 295.75 | 12-MAR-05:00 | 8.00 |
| April | 481725.90 | 62.96 | 24-APR-11:57 | 27.20 |
| May | 1139819.48 | 55.73 | 14-MAY-13:05 | 26.05 |
| June | 532618.09 | 53.93 | 07-JUN-08:57 | 26.70 |
| July | 318725.32 | 55.17 | 18-JUL-06:55 | 26.10 |
| August | 712381.42 | 55.54 | 27-AUG-07:47 | 26.50 |
| September | 900333.99 | 52.08 | 01-SEP-07:05 | 25.97 |
| October | 447047.17 | 52.32 | 12-OCT-09:07 | 26.33 |
| November | 306235.26 | 48.48 | 07-NOV-09:57 | 26.10 |
| December | 17767737.09 | 448.15 | 21-DEC-07:00 | 0.00 |
| Annual Sum or Average | 63432499.54 | |||
| Minimum of Months | 306235.26 | 48.48 | -3.4 | |
| Maximum of Months | 17860254.32 | 650.38 | 27.20 |
Report: ZoneHeatingSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 10451635.34 | 332.53 | 05-JAN-06:00 | 0.00 |
| February | 17966865.96 | 651.34 | 05-FEB-07:00 | -3.4 |
| March | 12557355.22 | 295.88 | 12-MAR-05:00 | 8.00 |
| April | 459825.14 | 62.94 | 24-APR-11:57 | 27.20 |
| May | 1135268.76 | 55.28 | 14-MAY-13:05 | 26.05 |
| June | 517150.09 | 54.06 | 07-JUN-08:57 | 26.70 |
| July | 318033.87 | 55.07 | 18-JUL-06:55 | 26.10 |
| August | 713355.61 | 55.63 | 27-AUG-07:47 | 26.50 |
| September | 903133.87 | 51.99 | 01-SEP-07:05 | 25.97 |
| October | 444779.69 | 52.38 | 12-OCT-09:07 | 26.33 |
| November | 301908.99 | 48.52 | 07-NOV-09:57 | 26.10 |
| December | 17882129.98 | 451.35 | 21-DEC-07:00 | 0.00 |
| Annual Sum or Average | 63651442.51 | |||
| Minimum of Months | 301908.99 | 48.52 | -3.4 | |
| Maximum of Months | 17966865.96 | 651.34 | 27.20 |
Report: ZoneHeatingSummaryMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 17.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 18.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 17.62 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 14.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 14.12 | |
| Maximum of Months | 0.00 | 0.00 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 17.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 18.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 17.62 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 14.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 14.12 | |
| Maximum of Months | 0.00 | 0.00 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 17.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 18.20 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 17.62 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 20.72 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 22.45 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 22.93 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 25.07 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 24.85 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 22.17 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 21.63 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 14.12 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 14.12 | |
| Maximum of Months | 0.00 | 0.00 | 25.13 |
Report: ZoneElectricSummaryMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.468251E+09 | 447.62 | 03-JAN-08:09 | 0.621586E+09 | 544.92 | 03-JAN-08:09 |
| February | 0.433623E+09 | 447.62 | 01-FEB-08:09 | 0.574385E+09 | 544.92 | 01-FEB-08:09 |
| March | 0.502522E+09 | 447.62 | 01-MAR-08:09 | 0.663122E+09 | 544.92 | 01-MAR-08:09 |
| April | 0.460516E+09 | 447.62 | 03-APR-07:10 | 0.610467E+09 | 544.92 | 03-APR-07:10 |
| May | 0.491098E+09 | 447.62 | 01-MAY-07:10 | 0.649277E+09 | 544.92 | 01-MAY-07:10 |
| June | 0.483363E+09 | 447.62 | 01-JUN-07:10 | 0.638158E+09 | 544.92 | 01-JUN-07:10 |
| July | 0.468251E+09 | 447.62 | 03-JUL-07:10 | 0.621586E+09 | 544.92 | 03-JUL-07:10 |
| August | 0.502522E+09 | 447.62 | 01-AUG-07:10 | 0.663122E+09 | 544.92 | 01-AUG-07:10 |
| September | 0.460516E+09 | 447.62 | 01-SEP-07:10 | 0.610467E+09 | 544.92 | 01-SEP-07:10 |
| October | 0.479675E+09 | 447.62 | 02-OCT-07:10 | 0.635432E+09 | 544.92 | 02-OCT-07:10 |
| November | 0.460516E+09 | 447.62 | 01-NOV-07:10 | 0.610467E+09 | 544.92 | 01-NOV-07:10 |
| December | 0.468251E+09 | 447.62 | 01-DEC-08:09 | 0.621586E+09 | 544.92 | 01-DEC-08:09 |
| Annual Sum or Average | 0.567911E+10 | 0.751966E+10 | ||||
| Minimum of Months | 0.433623E+09 | 447.62 | 0.574385E+09 | 544.92 | ||
| Maximum of Months | 0.502522E+09 | 447.62 | 0.663122E+09 | 544.92 |
Report: ZoneElectricSummaryMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
| January | 0.824800E+09 | 307.95 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.744981E+09 | 307.95 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.824800E+09 | 307.95 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.798194E+09 | 307.95 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.824800E+09 | 307.95 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.798194E+09 | 307.95 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 0.824800E+09 | 307.95 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 0.824800E+09 | 307.95 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 0.798194E+09 | 307.95 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 0.824800E+09 | 307.95 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.798194E+09 | 307.95 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.824800E+09 | 307.95 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.971136E+10 | 0.00 | 0.00 | ||
| Minimum of Months | 0.744981E+09 | 307.95 | 0.00 | 0.00 | |
| Maximum of Months | 0.824800E+09 | 307.95 | 0.00 | 0.00 |
Report: ZoneElectricSummaryMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.824800E+09 | 307.95 | 01-JAN-00:10 | 0.576651E+10 | 3803.87 | 01-JAN-07:10 |
| February | 0.744981E+09 | 307.95 | 01-FEB-00:10 | 0.520846E+10 | 3803.87 | 01-FEB-07:10 |
| March | 0.824800E+09 | 307.95 | 01-MAR-00:10 | 0.576651E+10 | 3803.87 | 01-MAR-07:10 |
| April | 0.798194E+09 | 307.95 | 01-APR-00:10 | 0.558049E+10 | 3803.87 | 01-APR-06:10 |
| May | 0.824800E+09 | 307.95 | 01-MAY-00:10 | 0.576651E+10 | 3803.87 | 01-MAY-06:10 |
| June | 0.798194E+09 | 307.95 | 01-JUN-00:10 | 0.558049E+10 | 3803.87 | 01-JUN-06:10 |
| July | 0.824800E+09 | 307.95 | 01-JUL-00:10 | 0.576651E+10 | 3803.87 | 01-JUL-06:10 |
| August | 0.824800E+09 | 307.95 | 01-AUG-00:10 | 0.576651E+10 | 3803.87 | 01-AUG-06:10 |
| September | 0.798194E+09 | 307.95 | 01-SEP-00:10 | 0.558049E+10 | 3803.87 | 01-SEP-06:10 |
| October | 0.824800E+09 | 307.95 | 01-OCT-00:10 | 0.576651E+10 | 3803.87 | 01-OCT-06:10 |
| November | 0.798194E+09 | 307.95 | 01-NOV-00:10 | 0.558049E+10 | 3803.87 | 01-NOV-06:10 |
| December | 0.824800E+09 | 307.95 | 01-DEC-00:10 | 0.576651E+10 | 3803.87 | 01-DEC-07:10 |
| Annual Sum or Average | 0.971136E+10 | 0.678960E+11 | ||||
| Minimum of Months | 0.744981E+09 | 307.95 | 0.520846E+10 | 3803.87 | ||
| Maximum of Months | 0.824800E+09 | 307.95 | 0.576651E+10 | 3803.87 |
Report: ZoneElectricSummaryMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
| January | 0.824800E+09 | 307.95 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.744981E+09 | 307.95 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.824800E+09 | 307.95 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.798194E+09 | 307.95 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.824800E+09 | 307.95 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.798194E+09 | 307.95 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 0.824800E+09 | 307.95 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 0.824800E+09 | 307.95 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 0.798194E+09 | 307.95 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 0.824800E+09 | 307.95 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.798194E+09 | 307.95 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.824800E+09 | 307.95 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.971136E+10 | 0.00 | 0.00 | ||
| Minimum of Months | 0.744981E+09 | 307.95 | 0.00 | 0.00 | |
| Maximum of Months | 0.824800E+09 | 307.95 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 439557.87 | 91870208.25 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 904264.65 | 65692282.00 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2566101.13 | 68444061.02 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5959780.22 | 24714442.60 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24104292.21 | 950995.25 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22868094.38 | 1141342.29 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27493175.98 | 290897.44 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29358845.77 | 1561560.82 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21735593.90 | 3691369.52 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20590450.14 | 21328626.06 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2486739.03 | 41244785.40 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1536986.65 | 77581397.17 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160044E+09 | 0.398512E+09 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 439557.87 | 290897.44 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29358845.77 | 91870208.25 |
Report: SpaceGainsMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 419234.96 | 85813488.20 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 881124.30 | 61060719.64 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2553789.38 | 65628780.75 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5964035.12 | 24400293.82 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24106318.60 | 956161.11 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22876114.55 | 1148189.66 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27494015.10 | 293790.56 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29358529.54 | 1562937.91 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21734423.37 | 3698704.82 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20451641.94 | 21202953.56 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2467792.18 | 40598212.76 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1529149.68 | 74325231.57 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159836E+09 | 0.380689E+09 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 419234.96 | 293790.56 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29358529.54 | 85813488.20 |
Report: SpaceGainsMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.227408E+09 | 0.468251E+09 | 0.621586E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 284260.65 | 93124231.50 |
| February | 0.216037E+09 | 0.433623E+09 | 0.574385E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 775442.83 | 65465256.82 |
| March | 0.261519E+09 | 0.502522E+09 | 0.663122E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1548633.84 | 72411796.95 |
| April | 0.227408E+09 | 0.460516E+09 | 0.610467E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3242545.36 | 30768348.92 |
| May | 0.250148E+09 | 0.491098E+09 | 0.649277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12922683.55 | 10979420.20 |
| June | 0.250148E+09 | 0.483363E+09 | 0.638158E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 13247885.85 | 7911573.42 |
| July | 0.227408E+09 | 0.468251E+09 | 0.621586E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12445137.90 | 7000112.42 |
| August | 0.261519E+09 | 0.502522E+09 | 0.663122E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16324554.34 | 13236135.89 |
| September | 0.227408E+09 | 0.460516E+09 | 0.610467E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 10636065.08 | 17732930.96 |
| October | 0.238778E+09 | 0.479675E+09 | 0.635432E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 10630705.60 | 38523555.06 |
| November | 0.227408E+09 | 0.460516E+09 | 0.610467E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1902257.65 | 47974027.21 |
| December | 0.227408E+09 | 0.468251E+09 | 0.621586E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 849873.38 | 82436430.10 |
| Annual Sum or Average | 0.284259E+10 | 0.567911E+10 | 0.751966E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 84810046.03 | 0.487564E+09 |
| Minimum of Months | 0.216037E+09 | 0.433623E+09 | 0.574385E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 284260.65 | 7000112.42 |
| Maximum of Months | 0.261519E+09 | 0.502522E+09 | 0.663122E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16324554.34 | 93124231.50 |
Report: SpaceGainsMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 418395.77 | 86016005.24 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 880429.55 | 61320343.53 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2540064.83 | 66028853.23 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5960910.32 | 24543972.27 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24104546.20 | 983535.59 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22874768.60 | 1158963.08 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27493907.73 | 296231.39 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29357993.91 | 1554708.22 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21734054.93 | 3691866.84 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20450091.20 | 21156930.15 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2466096.94 | 40696554.14 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1527816.03 | 74136874.85 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159809E+09 | 0.381585E+09 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 418395.77 | 296231.39 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29357993.91 | 86016005.24 |
Report: SpaceGainsMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 252482.73 | 53452755.36 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 529608.83 | 38297951.63 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1533068.33 | 40840864.83 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3596656.49 | 14768470.30 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14539905.39 | 576673.59 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13798485.88 | 688148.69 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16583644.76 | 167166.80 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17707622.98 | 915642.89 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13108619.55 | 2165438.52 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12332879.55 | 12621504.70 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1487551.64 | 24378011.33 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 921409.68 | 45677716.29 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 96391935.81 | 0.234550E+09 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 252482.73 | 167166.80 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17707622.98 | 53452755.36 |
Report: SpaceGainsMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 252468.18 | 53466897.95 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 529553.79 | 38308855.22 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1532718.74 | 40859919.64 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3596606.59 | 14775702.33 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14539876.75 | 577107.22 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13798452.08 | 687801.05 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16583638.48 | 167254.97 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17707598.06 | 915181.81 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13108601.25 | 2165106.09 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12332865.28 | 12615555.65 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1487503.95 | 24383145.38 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 921380.57 | 45665553.10 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 96391263.73 | 0.234588E+09 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 252468.18 | 167254.97 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17707598.06 | 53466897.95 |
Report: SpaceGainsMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 265028.14 | 55961354.71 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 545328.62 | 40317666.91 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1546385.49 | 42322518.69 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3593926.37 | 15032822.92 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14538478.57 | 574905.98 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13793665.23 | 684904.00 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16583156.35 | 166209.21 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17708064.77 | 917083.08 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13110039.73 | 2172968.85 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12418309.93 | 12845981.36 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1499365.73 | 24960376.59 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 926611.03 | 47175604.71 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 96528359.95 | 0.243132E+09 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 265028.14 | 166209.21 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17708064.77 | 55961354.71 |
Report: SpaceGainsMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 265024.81 | 55974182.70 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 545323.65 | 40296697.40 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1546133.25 | 42370585.84 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3593645.72 | 15128391.51 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14538071.94 | 607464.21 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13792713.21 | 709971.21 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16583050.77 | 171568.63 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17708137.42 | 942699.70 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13110111.18 | 2233309.81 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12418537.36 | 12975494.46 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1499382.97 | 25046399.22 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 926655.99 | 47232095.45 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 96526788.26 | 0.243689E+09 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 265024.81 | 171568.63 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17708137.42 | 55974182.70 |
Report: SpaceGainsMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 620096.25 | 0.132538E+09 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1283391.98 | 96069331.11 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3646055.79 | 0.102143E+09 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8508514.95 | 37438269.77 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34438300.07 | 1417684.25 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32714941.40 | 1664141.01 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39330568.88 | 417486.02 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 41988201.15 | 2136594.62 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31063873.18 | 4999146.66 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29425544.50 | 29961990.22 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3545877.54 | 59187149.16 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2191546.36 | 0.111282E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.228757E+09 | 0.579255E+09 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 620096.25 | 417486.02 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 41988201.15 | 0.132538E+09 |
Report: SpaceGainsMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 590888.71 | 0.124671E+09 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1238948.44 | 91532297.24 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3603249.41 | 99710125.18 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8511989.17 | 37319342.42 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34441033.43 | 1427556.13 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32726228.26 | 1668087.21 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39331678.93 | 421504.53 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 41988084.49 | 2134654.45 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31062247.21 | 4956105.98 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29235589.24 | 29305734.08 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3521309.99 | 57667804.68 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2180874.21 | 0.105657E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.228432E+09 | 0.556472E+09 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 590888.71 | 421504.53 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 41988084.49 | 0.124671E+09 |
Report: SpaceGainsMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 619708.83 | 0.132743E+09 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1282836.44 | 96236651.63 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3643369.09 | 0.102903E+09 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8506457.60 | 37910365.44 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34435543.67 | 1458954.88 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32712007.16 | 1691093.24 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39330048.37 | 421675.08 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 41986485.20 | 2119940.39 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31062343.38 | 4986007.53 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29422004.40 | 30074309.12 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3544539.67 | 59453086.33 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2190689.41 | 0.111249E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.228736E+09 | 0.581247E+09 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 619708.83 | 421675.08 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 41986485.20 | 0.132743E+09 |
Report: SpaceGainsMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 590294.86 | 0.125091E+09 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1237660.29 | 91817393.25 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3600375.20 | 0.100199E+09 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8510152.84 | 37978539.70 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34439081.05 | 1464627.75 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32724357.91 | 1689609.99 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39331287.59 | 425291.01 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 41986109.98 | 2122283.59 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31060720.21 | 4954319.00 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29228015.55 | 29289268.02 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3518244.68 | 57769659.08 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2179149.79 | 0.105453E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.228405E+09 | 0.558253E+09 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 590294.86 | 425291.01 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 41986109.98 | 0.125091E+09 |
Report: SpaceGainsMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 356027.22 | 77955319.02 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 746695.03 | 56637597.97 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2172573.67 | 60908148.75 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5133422.40 | 22150778.57 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20773408.44 | 833647.43 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19740529.95 | 983335.11 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23723854.94 | 234435.16 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25325676.80 | 1249013.71 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18735277.45 | 2897655.23 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17632998.69 | 17493707.88 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2123237.62 | 34710513.62 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1314511.17 | 65538694.16 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.137778E+09 | 0.341593E+09 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 356027.22 | 234435.16 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25325676.80 | 77955319.02 |
Report: SpaceGainsMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 356021.06 | 77982737.04 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 746655.28 | 56649213.36 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2172482.14 | 60940178.67 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5133337.03 | 22171267.89 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20773385.19 | 834062.63 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19740479.96 | 983178.70 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23723849.95 | 234541.99 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25325661.97 | 1248530.00 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18735250.00 | 2897121.24 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17632775.45 | 17489363.94 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2123134.49 | 34720237.09 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1314468.51 | 65520922.02 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.137778E+09 | 0.341671E+09 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 356021.06 | 234541.99 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25325661.97 | 77982737.04 |
Report: SpaceGainsMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 373782.85 | 80828922.54 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 773673.77 | 58599444.99 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2197648.92 | 62218640.30 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5130864.16 | 22464329.34 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20771436.54 | 828101.41 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19733663.01 | 979987.90 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23723170.85 | 232672.66 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25325778.89 | 1250823.12 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18735974.39 | 2938363.39 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17746603.45 | 18093990.25 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2137734.55 | 35859840.78 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1321178.37 | 67853397.15 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.137972E+09 | 0.352149E+09 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 373782.85 | 232672.66 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25325778.89 | 80828922.54 |
Report: SpaceGainsMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 373767.17 | 80837687.72 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 773670.56 | 58602762.95 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2197601.80 | 62236326.08 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5130841.06 | 22479988.02 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20771403.58 | 828519.18 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19733598.10 | 979862.42 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23723165.68 | 232778.68 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25325765.47 | 1250349.80 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18735965.33 | 2937289.67 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17746582.97 | 18093632.65 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2137705.04 | 35867060.03 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1321162.04 | 67849263.53 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.137971E+09 | 0.352196E+09 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 373767.17 | 232778.68 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25325765.47 | 80837687.72 |
Report: SpaceGainsMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 789883.47 | 0.162191E+09 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1655277.63 | 0.118899E+09 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4721844.92 | 0.125952E+09 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11114089.57 | 48971683.70 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45025276.72 | 1930120.96 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 42881239.14 | 2234157.65 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 51551299.15 | 651499.45 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 55001738.84 | 2972084.20 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 40634553.27 | 6987849.63 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38489400.35 | 38664733.61 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4617113.46 | 75718228.25 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2853623.17 | 0.135492E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.299335E+09 | 0.720664E+09 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 789883.47 | 651499.45 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 55001738.84 | 0.162191E+09 |
Report: SpaceGainsMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 753862.86 | 0.148560E+09 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1600684.18 | 0.110200E+09 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4667326.32 | 0.121600E+09 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11118974.87 | 49457327.39 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45028335.14 | 1951443.61 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 42896498.64 | 2236236.09 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 51552676.79 | 661642.28 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 55000975.91 | 2984842.60 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 40632418.78 | 6992066.63 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38245858.22 | 36812145.83 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4596824.51 | 70099444.61 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2845566.56 | 0.123642E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.298940E+09 | 0.675197E+09 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 753862.86 | 661642.28 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 55000975.91 | 0.148560E+09 |
Report: SpaceGainsMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 788566.57 | 0.163365E+09 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1653816.09 | 0.119379E+09 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4716484.58 | 0.127878E+09 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11109276.52 | 50011515.79 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45020923.36 | 1993362.45 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 42878275.73 | 2290481.97 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 51550384.84 | 660630.03 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 54998916.74 | 2945135.23 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 40631774.38 | 6981365.27 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38481925.62 | 38963449.77 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4614128.30 | 76465916.65 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2852267.06 | 0.135910E+09 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.299297E+09 | 0.726845E+09 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 788566.57 | 660630.03 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 54998916.74 | 0.163365E+09 |
Report: SpaceGainsMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 752528.75 | 0.148111E+09 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1596531.42 | 0.110550E+09 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4662203.73 | 0.122697E+09 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11114483.32 | 50330493.97 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45025546.87 | 2006546.12 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 42894230.11 | 2282646.84 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 51551901.47 | 668154.63 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 54998403.88 | 2949696.09 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 40629855.54 | 6988705.90 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38236213.91 | 36753752.08 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4581271.32 | 70832004.52 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2839039.42 | 0.123407E+09 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.298882E+09 | 0.677578E+09 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 752528.75 | 668154.63 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 54998403.88 | 0.148111E+09 |
Report: SpaceGainsMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 454159.24 | 90093774.93 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 963947.34 | 67443017.36 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2813533.32 | 74044936.90 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6705065.25 | 29727639.72 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27158564.74 | 1178445.38 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25873524.31 | 1350010.20 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31095018.34 | 370320.40 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 33173403.01 | 1771541.09 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24507042.56 | 4165832.20 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23065519.69 | 22301652.58 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2768515.73 | 43243220.54 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1713911.70 | 75900596.52 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.180292E+09 | 0.411591E+09 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 454159.24 | 370320.40 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 33173403.01 | 90093774.93 |
Report: SpaceGainsMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 454116.10 | 90101295.80 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 963677.07 | 67472292.94 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2813251.23 | 74113695.54 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6704948.25 | 29786927.82 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27158495.39 | 1178897.09 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25873497.27 | 1349915.24 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31095012.57 | 370765.39 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 33173349.71 | 1770204.63 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24506980.97 | 4164539.70 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23065194.80 | 22291508.98 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2767828.88 | 43279673.95 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1713707.90 | 75869480.05 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.180290E+09 | 0.411749E+09 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 454116.10 | 370765.39 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 33173349.71 | 90101295.80 |
Report: SpaceGainsMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 475864.67 | 0.100509E+09 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 997537.14 | 73537389.58 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2845657.09 | 77346811.75 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6701946.67 | 29768170.39 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27156405.72 | 1164529.01 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25864168.88 | 1349893.85 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31094230.47 | 366450.93 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 33173656.58 | 1768630.60 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24508058.65 | 4177851.96 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23212709.04 | 23687994.07 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2783090.11 | 46780323.83 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1720406.22 | 84402520.92 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.180534E+09 | 0.444860E+09 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 475864.67 | 366450.93 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 33173656.58 | 0.100509E+09 |
Report: SpaceGainsMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 475814.49 | 0.100554E+09 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 997497.79 | 73554857.75 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2845481.05 | 77483933.68 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6701751.55 | 29802605.76 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27156285.27 | 1165134.55 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25864066.96 | 1350173.43 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31094217.19 | 366645.53 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 33173604.52 | 1762588.82 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24508021.90 | 4176146.14 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23212551.53 | 23696640.78 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2782996.10 | 46798312.14 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1720362.54 | 84401709.56 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.180533E+09 | 0.445113E+09 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 475814.49 | 366645.53 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 33173604.52 | 0.100554E+09 |
Report: SpaceGainsMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4595.15 | 28745697.28 |
| February | 0.657255E+09 | 0.744981E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43320.49 | 21390184.73 |
| March | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 129399.95 | 24007652.87 |
| April | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 669824.25 | 10395917.17 |
| May | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3472276.44 | 1658466.42 |
| June | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3688947.63 | 1186250.04 |
| July | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4457006.19 | 587931.16 |
| August | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4740715.98 | 1785547.60 |
| September | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3244654.08 | 3083835.72 |
| October | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2740684.58 | 9061888.11 |
| November | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 238181.46 | 14556155.41 |
| December | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 127162.48 | 24477994.63 |
| Annual Sum or Average | 0.856778E+10 | 0.971136E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23556768.68 | 0.140938E+09 |
| Minimum of Months | 0.657255E+09 | 0.744981E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4595.15 | 587931.16 |
| Maximum of Months | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4740715.98 | 28745697.28 |
Report: SpaceGainsMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 90447.42 | 0.236777E+10 |
| February | 0.657255E+09 | 0.744981E+09 | 0.260423E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 771106.57 | 0.177564E+10 |
| March | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5252935.92 | 0.165221E+10 |
| April | 0.704201E+09 | 0.798194E+09 | 0.279025E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 53614551.08 | 0.952029E+09 |
| May | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.271564E+09 | 0.217381E+09 |
| June | 0.704201E+09 | 0.798194E+09 | 0.279025E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.333645E+09 | 0.145963E+09 |
| July | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.321913E+09 | 0.148430E+09 |
| August | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.306326E+09 | 0.227009E+09 |
| September | 0.704201E+09 | 0.798194E+09 | 0.279025E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.154160E+09 | 0.340318E+09 |
| October | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.115703E+09 | 0.642309E+09 |
| November | 0.704201E+09 | 0.798194E+09 | 0.279025E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9022614.91 | 0.146302E+10 |
| December | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3804667.97 | 0.204680E+10 |
| Annual Sum or Average | 0.856778E+10 | 0.971136E+10 | 0.339480E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.157587E+10 | 0.119789E+11 |
| Minimum of Months | 0.657255E+09 | 0.744981E+09 | 0.260423E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 90447.42 | 0.145963E+09 |
| Maximum of Months | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.333645E+09 | 0.236777E+10 |
Report: SpaceGainsMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3091.67 | 25196078.62 |
| February | 0.657255E+09 | 0.744981E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29104.78 | 18514909.34 |
| March | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 111666.45 | 20527318.39 |
| April | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 592518.78 | 8238748.70 |
| May | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3023804.71 | 1162618.22 |
| June | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3224810.33 | 863324.60 |
| July | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3874726.61 | 394202.55 |
| August | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4078453.39 | 1227865.70 |
| September | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2787782.62 | 2215423.81 |
| October | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2444161.71 | 7293510.68 |
| November | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 196812.90 | 12199859.84 |
| December | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 107516.49 | 21531805.98 |
| Annual Sum or Average | 0.856778E+10 | 0.971136E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20474450.44 | 0.119366E+09 |
| Minimum of Months | 0.657255E+09 | 0.744981E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3091.67 | 394202.55 |
| Maximum of Months | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4078453.39 | 25196078.62 |
Report: PeakSpaceGainsMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 9.95 | 19-JAN-12:10 | 118.73 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 27.12 | 02-FEB-13:00 | 161.50 | 16-FEB-18:30 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.82 | 28-MAR-14:00 | 118.96 | 20-MAR-22:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 43.98 | 29-APR-16:00 | 65.24 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.46 | 25-MAY-14:00 | 12.56 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 55.87 | 08-JUN-15:00 | 24.08 | 06-JUN-19:53 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 96.32 | 19-JUL-13:00 | 14.54 | 12-JUL-15:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.44 | 20-AUG-14:00 | 24.09 | 25-AUG-21:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.37 | 09-SEP-23:00 | 29.59 | 19-SEP-18:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 75.56 | 09-OCT-14:00 | 59.31 | 28-OCT-08:20 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 21.04 | 07-NOV-13:00 | 79.87 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.72 | 13-DEC-14:00 | 131.73 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 9.95 | 12.56 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 96.32 | 161.50 |
Report: PeakSpaceGainsMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 9.95 | 19-JAN-12:10 | 113.21 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 27.12 | 02-FEB-13:00 | 158.31 | 16-FEB-18:01 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.82 | 28-MAR-14:00 | 116.09 | 20-MAR-19:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 43.98 | 29-APR-16:00 | 65.24 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.46 | 25-MAY-14:00 | 12.67 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 55.87 | 08-JUN-15:00 | 24.08 | 06-JUN-19:53 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 96.32 | 19-JUL-13:00 | 14.57 | 12-JUL-15:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.44 | 20-AUG-14:00 | 23.90 | 25-AUG-21:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.37 | 09-SEP-23:00 | 29.37 | 19-SEP-18:53 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 75.56 | 09-OCT-14:00 | 59.31 | 28-OCT-08:20 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 21.04 | 07-NOV-13:00 | 79.87 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.72 | 13-DEC-14:00 | 128.22 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 9.95 | 12.67 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 96.32 | 158.31 |
Report: PeakSpaceGainsMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 451.21 | 03-JAN-08:09 | 447.62 | 03-JAN-08:09 | 544.92 | 03-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 9.95 | 19-JAN-12:10 | 118.73 | 09-JAN-17:00 |
| February | 451.21 | 01-FEB-08:09 | 447.62 | 01-FEB-08:09 | 544.92 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 27.12 | 02-FEB-13:00 | 162.84 | 16-FEB-18:01 |
| March | 451.21 | 01-MAR-08:09 | 447.62 | 01-MAR-08:09 | 544.92 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 26.82 | 28-MAR-14:00 | 121.63 | 20-MAR-19:00 |
| April | 451.21 | 03-APR-07:10 | 447.62 | 03-APR-07:10 | 544.92 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 35.96 | 28-APR-15:00 | 75.33 | 01-APR-17:55 |
| May | 451.21 | 01-MAY-07:10 | 447.62 | 01-MAY-07:10 | 544.92 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.46 | 25-MAY-14:00 | 27.05 | 14-MAY-12:00 |
| June | 451.21 | 01-JUN-07:10 | 447.62 | 01-JUN-07:10 | 544.92 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 55.87 | 08-JUN-15:00 | 37.16 | 06-JUN-20:55 |
| July | 451.21 | 03-JUL-07:10 | 447.62 | 03-JUL-07:10 | 544.92 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 96.30 | 19-JUL-13:00 | 29.84 | 30-JUL-11:00 |
| August | 451.21 | 01-AUG-07:10 | 447.62 | 01-AUG-07:10 | 544.92 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 53.91 | 03-AUG-16:00 | 38.47 | 16-AUG-04:00 |
| September | 451.21 | 01-SEP-07:10 | 447.62 | 01-SEP-07:10 | 544.92 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 49.95 | 13-SEP-13:00 | 46.68 | 05-SEP-03:00 |
| October | 451.21 | 02-OCT-07:10 | 447.62 | 02-OCT-07:10 | 544.92 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 49.90 | 10-OCT-15:00 | 67.36 | 17-OCT-06:00 |
| November | 451.21 | 01-NOV-07:10 | 447.62 | 01-NOV-07:10 | 544.92 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 21.04 | 07-NOV-13:00 | 87.72 | 12-NOV-08:00 |
| December | 451.21 | 01-DEC-08:09 | 447.62 | 01-DEC-08:09 | 544.92 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 19.72 | 13-DEC-14:00 | 130.66 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 451.21 | 447.62 | 544.92 | 0.00 | 0.00 | 0.00 | 0.00 | 9.95 | 27.05 | |||||
| Maximum of Months | 451.21 | 447.62 | 544.92 | 0.00 | 0.00 | 0.00 | 0.00 | 96.30 | 162.84 |
Report: PeakSpaceGainsMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 9.95 | 19-JAN-12:10 | 111.21 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 27.12 | 02-FEB-13:00 | 155.76 | 16-FEB-18:01 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.82 | 28-MAR-14:00 | 116.09 | 20-MAR-19:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 43.98 | 29-APR-16:00 | 65.24 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.46 | 25-MAY-14:00 | 12.57 | 05-MAY-06:10 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 55.87 | 08-JUN-15:00 | 24.35 | 06-JUN-20:10 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 96.32 | 19-JUL-13:00 | 14.17 | 12-JUL-15:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.44 | 20-AUG-14:00 | 23.32 | 25-AUG-21:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.37 | 09-SEP-23:00 | 28.38 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 75.56 | 09-OCT-14:00 | 59.31 | 28-OCT-08:20 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 21.04 | 07-NOV-13:00 | 79.87 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.72 | 13-DEC-14:00 | 128.07 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 9.95 | 12.57 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 96.32 | 155.76 |
Report: PeakSpaceGainsMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 19-JAN-12:10 | 69.66 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16.36 | 02-FEB-13:00 | 97.46 | 16-FEB-18:30 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16.17 | 28-MAR-14:00 | 72.18 | 20-MAR-22:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.53 | 29-APR-16:00 | 39.37 | 01-APR-17:55 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 31.04 | 25-MAY-14:00 | 7.56 | 05-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 33.70 | 08-JUN-15:00 | 14.70 | 06-JUN-20:10 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.10 | 19-JUL-13:00 | 7.70 | 12-JUL-15:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 35.25 | 20-AUG-14:00 | 13.41 | 25-AUG-21:20 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.99 | 09-SEP-23:00 | 16.50 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.58 | 09-OCT-14:00 | 35.78 | 28-OCT-08:20 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12.69 | 07-NOV-13:00 | 48.18 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 11.90 | 13-DEC-14:00 | 80.22 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 7.56 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 58.10 | 97.46 |
Report: PeakSpaceGainsMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 19-JAN-12:10 | 69.69 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16.36 | 02-FEB-13:00 | 97.46 | 16-FEB-18:30 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16.17 | 28-MAR-14:00 | 72.20 | 20-MAR-22:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.53 | 29-APR-16:00 | 39.41 | 01-APR-17:55 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 31.04 | 25-MAY-14:00 | 7.56 | 05-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 33.70 | 08-JUN-15:00 | 14.70 | 06-JUN-20:10 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.10 | 19-JUL-13:00 | 7.71 | 12-JUL-15:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 35.25 | 20-AUG-14:00 | 13.40 | 25-AUG-21:20 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.99 | 09-SEP-23:00 | 16.48 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.58 | 09-OCT-14:00 | 35.78 | 28-OCT-08:20 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12.69 | 07-NOV-13:00 | 48.18 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 11.90 | 13-DEC-14:00 | 80.22 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 7.56 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 58.10 | 97.46 |
Report: PeakSpaceGainsMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 19-JAN-12:10 | 71.61 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16.36 | 02-FEB-13:00 | 97.42 | 16-FEB-18:30 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16.17 | 28-MAR-14:00 | 72.23 | 20-MAR-22:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.53 | 29-APR-16:00 | 39.35 | 01-APR-21:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 31.04 | 25-MAY-14:00 | 7.40 | 05-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 33.70 | 08-JUN-15:00 | 14.70 | 06-JUN-20:10 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.10 | 19-JUL-13:00 | 7.78 | 12-JUL-15:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 35.25 | 20-AUG-14:00 | 13.91 | 25-AUG-21:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.99 | 09-SEP-23:00 | 16.72 | 19-SEP-18:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.58 | 09-OCT-14:00 | 35.78 | 28-OCT-08:20 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12.69 | 07-NOV-13:00 | 48.18 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 11.90 | 13-DEC-14:00 | 81.58 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 7.40 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 58.10 | 97.42 |
Report: PeakSpaceGainsMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 19-JAN-12:10 | 71.61 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16.36 | 02-FEB-13:00 | 97.42 | 16-FEB-18:30 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16.17 | 28-MAR-14:00 | 72.23 | 20-MAR-22:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.53 | 29-APR-16:00 | 39.53 | 01-APR-18:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 31.04 | 25-MAY-14:00 | 7.75 | 05-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 33.70 | 08-JUN-15:00 | 14.63 | 06-JUN-20:10 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.10 | 19-JUL-13:00 | 8.04 | 12-JUL-15:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 35.25 | 20-AUG-14:00 | 14.35 | 25-AUG-21:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.99 | 09-SEP-23:00 | 17.11 | 19-SEP-18:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.58 | 09-OCT-14:00 | 35.78 | 28-OCT-08:20 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12.69 | 07-NOV-13:00 | 48.18 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 11.90 | 13-DEC-14:00 | 81.58 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 7.75 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 58.10 | 97.42 |
Report: PeakSpaceGainsMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.15 | 19-JAN-12:10 | 170.83 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.79 | 02-FEB-13:00 | 232.43 | 16-FEB-18:30 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.30 | 28-MAR-14:00 | 172.32 | 20-MAR-22:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 63.00 | 29-APR-16:00 | 104.42 | 01-APR-17:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 73.78 | 25-MAY-14:00 | 18.41 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 80.10 | 08-JUN-15:00 | 35.36 | 06-JUN-21:20 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 138.14 | 19-JUL-13:00 | 20.65 | 12-JUL-15:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.81 | 20-AUG-14:00 | 32.83 | 25-AUG-21:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 73.68 | 09-SEP-23:00 | 39.87 | 19-SEP-18:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 108.28 | 09-OCT-14:00 | 85.36 | 28-OCT-08:20 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.10 | 07-NOV-13:00 | 114.92 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 28.23 | 13-DEC-14:00 | 185.55 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 14.15 | 18.41 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 138.14 | 232.43 |
Report: PeakSpaceGainsMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.15 | 19-JAN-12:10 | 164.76 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.79 | 02-FEB-13:00 | 232.43 | 16-FEB-18:30 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.30 | 28-MAR-14:00 | 172.06 | 20-MAR-22:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 63.00 | 29-APR-16:00 | 99.31 | 01-APR-17:55 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 73.78 | 25-MAY-14:00 | 18.83 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 80.10 | 08-JUN-15:00 | 35.08 | 06-JUN-21:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 138.14 | 19-JUL-13:00 | 20.68 | 12-JUL-15:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.81 | 20-AUG-14:00 | 31.40 | 25-AUG-21:20 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 73.68 | 09-SEP-23:00 | 39.61 | 19-SEP-18:53 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 108.28 | 09-OCT-14:00 | 85.36 | 28-OCT-08:20 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.10 | 07-NOV-13:00 | 114.92 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 28.23 | 13-DEC-14:00 | 179.75 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 14.15 | 18.83 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 138.14 | 232.43 |
Report: PeakSpaceGainsMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.15 | 19-JAN-12:10 | 170.83 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.79 | 02-FEB-13:00 | 232.43 | 16-FEB-18:30 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.30 | 28-MAR-14:00 | 172.32 | 20-MAR-22:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 63.00 | 29-APR-16:00 | 103.62 | 01-APR-17:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 73.78 | 25-MAY-14:00 | 18.14 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 80.10 | 08-JUN-15:00 | 35.15 | 06-JUN-20:10 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 138.14 | 19-JUL-13:00 | 19.98 | 12-JUL-15:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.81 | 20-AUG-14:00 | 31.06 | 25-AUG-21:20 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 73.68 | 09-SEP-23:00 | 38.25 | 19-SEP-18:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 108.28 | 09-OCT-14:00 | 85.36 | 28-OCT-08:20 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.10 | 07-NOV-13:00 | 114.92 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 28.23 | 13-DEC-14:00 | 185.28 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 14.15 | 18.14 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 138.14 | 232.43 |
Report: PeakSpaceGainsMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.15 | 19-JAN-12:10 | 161.76 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.79 | 02-FEB-13:00 | 232.30 | 16-FEB-18:25 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.30 | 28-MAR-14:00 | 171.90 | 20-MAR-22:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 63.00 | 29-APR-16:00 | 112.62 | 01-APR-17:55 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 73.78 | 25-MAY-14:00 | 18.38 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 80.10 | 08-JUN-15:00 | 35.15 | 06-JUN-20:10 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 138.14 | 19-JUL-13:00 | 20.00 | 12-JUL-15:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.81 | 20-AUG-14:00 | 30.70 | 25-AUG-21:20 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 73.68 | 09-SEP-23:00 | 37.89 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 108.28 | 09-OCT-14:00 | 85.36 | 28-OCT-08:20 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.10 | 07-NOV-13:00 | 114.92 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 28.23 | 13-DEC-14:00 | 179.58 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 14.15 | 18.38 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 138.14 | 232.30 |
Report: PeakSpaceGainsMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8.53 | 19-JAN-12:10 | 101.84 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.40 | 02-FEB-13:00 | 140.19 | 16-FEB-18:30 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.10 | 28-MAR-14:00 | 103.94 | 20-MAR-22:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.00 | 29-APR-16:00 | 59.31 | 01-APR-17:55 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.51 | 25-MAY-14:00 | 10.53 | 05-MAY-06:10 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.31 | 08-JUN-15:00 | 20.78 | 06-JUN-20:10 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.32 | 19-JUL-13:00 | 10.53 | 12-JUL-15:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.55 | 20-AUG-14:00 | 18.12 | 25-AUG-21:20 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.44 | 09-SEP-23:00 | 21.95 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 65.31 | 09-OCT-14:00 | 51.49 | 28-OCT-08:20 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.16 | 07-NOV-13:00 | 69.32 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 17.03 | 13-DEC-14:00 | 114.36 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 8.53 | 10.53 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 83.32 | 140.19 |
Report: PeakSpaceGainsMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8.53 | 19-JAN-12:10 | 101.90 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.40 | 02-FEB-13:00 | 140.19 | 16-FEB-18:30 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.10 | 28-MAR-14:00 | 103.94 | 20-MAR-22:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.00 | 29-APR-16:00 | 59.52 | 01-APR-17:55 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.51 | 25-MAY-14:00 | 10.52 | 05-MAY-06:10 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.31 | 08-JUN-15:00 | 20.75 | 06-JUN-20:10 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.32 | 19-JUL-13:00 | 10.54 | 12-JUL-15:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.55 | 20-AUG-14:00 | 18.11 | 25-AUG-21:20 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.44 | 09-SEP-23:00 | 21.91 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 65.31 | 09-OCT-14:00 | 51.49 | 28-OCT-08:20 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.16 | 07-NOV-13:00 | 69.32 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 17.03 | 13-DEC-14:00 | 114.35 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 8.53 | 10.52 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 83.32 | 140.19 |
Report: PeakSpaceGainsMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8.53 | 19-JAN-12:10 | 103.04 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.40 | 02-FEB-13:00 | 140.19 | 16-FEB-18:30 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.10 | 28-MAR-14:00 | 103.94 | 20-MAR-22:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.00 | 29-APR-16:00 | 61.29 | 01-APR-17:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.51 | 25-MAY-14:00 | 10.27 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.31 | 08-JUN-15:00 | 20.77 | 06-JUN-20:10 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.32 | 19-JUL-13:00 | 10.65 | 12-JUL-15:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.55 | 20-AUG-14:00 | 18.36 | 25-AUG-21:20 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.44 | 09-SEP-23:00 | 22.89 | 19-SEP-18:53 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 65.31 | 09-OCT-14:00 | 51.49 | 28-OCT-08:20 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.16 | 07-NOV-13:00 | 69.32 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 17.03 | 13-DEC-14:00 | 116.34 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 8.53 | 10.27 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 83.32 | 140.19 |
Report: PeakSpaceGainsMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8.53 | 19-JAN-12:10 | 103.04 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.40 | 02-FEB-13:00 | 140.19 | 16-FEB-18:30 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.10 | 28-MAR-14:00 | 103.94 | 20-MAR-22:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.00 | 29-APR-16:00 | 61.38 | 01-APR-17:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.51 | 25-MAY-14:00 | 10.27 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.31 | 08-JUN-15:00 | 20.75 | 06-JUN-20:10 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.32 | 19-JUL-13:00 | 10.66 | 12-JUL-15:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.55 | 20-AUG-14:00 | 18.34 | 25-AUG-21:20 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.44 | 09-SEP-23:00 | 22.89 | 19-SEP-18:53 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 65.31 | 09-OCT-14:00 | 51.49 | 28-OCT-08:20 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.16 | 07-NOV-13:00 | 69.32 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 17.03 | 13-DEC-14:00 | 116.33 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 8.53 | 10.27 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 83.32 | 140.19 |
Report: PeakSpaceGainsMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.31 | 19-JAN-12:10 | 226.53 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.84 | 02-FEB-13:00 | 308.24 | 16-FEB-18:18 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.03 | 28-MAR-14:00 | 221.85 | 20-MAR-19:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 82.78 | 29-APR-16:00 | 153.88 | 01-APR-17:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 97.16 | 25-MAY-14:00 | 28.16 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 105.44 | 08-JUN-15:00 | 52.75 | 06-JUN-21:20 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 181.99 | 19-JUL-13:00 | 38.45 | 12-JUL-15:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 110.42 | 20-AUG-14:00 | 47.06 | 25-AUG-21:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 97.08 | 09-SEP-23:00 | 63.70 | 19-SEP-18:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 142.42 | 09-OCT-14:00 | 111.00 | 28-OCT-15:00 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 39.45 | 07-NOV-13:00 | 141.25 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.05 | 13-DEC-14:00 | 211.45 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 18.31 | 28.16 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 181.99 | 308.24 |
Report: PeakSpaceGainsMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.31 | 19-JAN-12:10 | 196.17 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.84 | 02-FEB-13:00 | 292.43 | 16-FEB-18:01 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.03 | 28-MAR-14:00 | 219.47 | 20-MAR-19:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 82.78 | 29-APR-16:00 | 164.39 | 01-APR-17:55 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 97.16 | 25-MAY-14:00 | 28.42 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 105.44 | 08-JUN-15:00 | 51.73 | 06-JUN-21:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 181.99 | 19-JUL-13:00 | 38.21 | 12-JUL-15:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 110.42 | 20-AUG-14:00 | 46.63 | 25-AUG-21:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 97.08 | 09-SEP-23:00 | 62.39 | 19-SEP-18:55 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 142.42 | 09-OCT-14:00 | 106.25 | 27-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 39.45 | 07-NOV-13:00 | 137.47 | 12-NOV-07:01 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.05 | 13-DEC-14:00 | 211.45 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 18.31 | 28.42 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 181.99 | 292.43 |
Report: PeakSpaceGainsMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.31 | 19-JAN-12:10 | 226.53 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.84 | 02-FEB-13:00 | 307.19 | 16-FEB-18:01 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.03 | 28-MAR-14:00 | 221.85 | 20-MAR-19:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 82.78 | 29-APR-16:00 | 148.99 | 01-APR-17:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 97.16 | 25-MAY-14:00 | 26.72 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 105.44 | 08-JUN-15:00 | 50.28 | 06-JUN-21:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 181.99 | 19-JUL-13:00 | 36.62 | 12-JUL-15:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 110.42 | 20-AUG-14:00 | 44.87 | 25-AUG-21:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 97.08 | 09-SEP-23:00 | 59.24 | 19-SEP-18:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 142.42 | 09-OCT-14:00 | 110.30 | 27-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 39.45 | 07-NOV-13:00 | 145.44 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.05 | 13-DEC-14:00 | 211.45 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 18.31 | 26.72 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 181.99 | 307.19 |
Report: PeakSpaceGainsMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.31 | 19-JAN-12:10 | 187.26 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.84 | 02-FEB-13:00 | 284.09 | 16-FEB-18:01 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.03 | 28-MAR-14:00 | 214.37 | 20-MAR-19:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 82.78 | 29-APR-16:00 | 160.85 | 01-APR-17:55 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 97.16 | 25-MAY-14:00 | 27.54 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 105.44 | 08-JUN-15:00 | 49.63 | 06-JUN-21:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 181.99 | 19-JUL-13:00 | 36.26 | 12-JUL-15:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 110.42 | 20-AUG-14:00 | 43.14 | 25-AUG-21:30 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 97.08 | 09-SEP-23:00 | 58.19 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 142.42 | 09-OCT-14:00 | 108.11 | 27-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 39.45 | 07-NOV-13:00 | 140.27 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.05 | 13-DEC-14:00 | 211.45 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 18.31 | 27.54 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 181.99 | 284.09 |
Report: PeakSpaceGainsMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 11.04 | 19-JAN-12:10 | 116.66 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.66 | 02-FEB-13:00 | 179.97 | 16-FEB-18:01 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.18 | 28-MAR-14:00 | 133.61 | 20-MAR-19:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 49.93 | 29-APR-16:00 | 98.00 | 01-APR-17:55 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.61 | 25-MAY-14:00 | 15.65 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 63.60 | 08-JUN-15:00 | 30.22 | 06-JUN-21:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 109.77 | 19-JUL-13:00 | 19.60 | 12-JUL-15:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 66.60 | 20-AUG-14:00 | 26.37 | 25-AUG-21:30 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.55 | 09-SEP-23:00 | 34.66 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 85.90 | 09-OCT-14:00 | 66.54 | 27-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.80 | 07-NOV-13:00 | 86.95 | 12-NOV-07:01 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 22.35 | 13-DEC-14:00 | 127.54 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 11.04 | 15.65 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 109.77 | 179.97 |
Report: PeakSpaceGainsMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 11.04 | 19-JAN-12:10 | 116.65 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.66 | 02-FEB-13:00 | 179.88 | 16-FEB-18:01 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.18 | 28-MAR-14:00 | 133.62 | 20-MAR-19:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 49.93 | 29-APR-16:00 | 98.06 | 01-APR-17:55 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.61 | 25-MAY-14:00 | 15.63 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 63.60 | 08-JUN-15:00 | 30.13 | 06-JUN-21:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 109.77 | 19-JUL-13:00 | 19.62 | 12-JUL-15:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 66.60 | 20-AUG-14:00 | 26.27 | 25-AUG-21:30 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.55 | 09-SEP-23:00 | 34.50 | 19-SEP-19:00 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 85.90 | 09-OCT-14:00 | 66.54 | 27-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.80 | 07-NOV-13:00 | 86.93 | 12-NOV-07:01 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 22.35 | 13-DEC-14:00 | 127.54 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 11.04 | 15.63 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 109.77 | 179.88 |
Report: PeakSpaceGainsMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 11.04 | 19-JAN-12:10 | 136.64 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.66 | 02-FEB-13:00 | 185.98 | 16-FEB-18:30 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.18 | 28-MAR-14:00 | 134.03 | 20-MAR-22:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 49.93 | 29-APR-16:00 | 90.69 | 01-APR-17:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.61 | 25-MAY-14:00 | 15.41 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 63.60 | 08-JUN-15:00 | 30.66 | 06-JUN-21:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 109.77 | 19-JUL-13:00 | 19.78 | 12-JUL-15:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 66.60 | 20-AUG-14:00 | 27.36 | 25-AUG-21:20 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.55 | 09-SEP-23:00 | 35.40 | 19-SEP-18:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 85.90 | 09-OCT-14:00 | 66.78 | 28-OCT-09:00 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.80 | 07-NOV-13:00 | 89.68 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 22.35 | 13-DEC-14:00 | 127.55 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 11.04 | 15.41 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 109.77 | 185.98 |
Report: PeakSpaceGainsMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 11.04 | 19-JAN-12:10 | 136.64 | 09-JAN-17:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.66 | 02-FEB-13:00 | 185.98 | 16-FEB-18:30 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.18 | 28-MAR-14:00 | 134.18 | 20-MAR-22:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 49.93 | 29-APR-16:00 | 90.71 | 01-APR-17:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.61 | 25-MAY-14:00 | 15.39 | 19-MAY-19:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 63.60 | 08-JUN-15:00 | 30.57 | 06-JUN-21:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 109.77 | 19-JUL-13:00 | 19.80 | 12-JUL-15:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 66.60 | 20-AUG-14:00 | 26.56 | 25-AUG-21:30 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.55 | 09-SEP-23:00 | 35.25 | 19-SEP-18:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 85.90 | 09-OCT-14:00 | 66.88 | 28-OCT-09:00 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.80 | 07-NOV-13:00 | 89.70 | 12-NOV-08:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 22.35 | 13-DEC-14:00 | 127.54 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 11.04 | 15.39 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 109.77 | 185.98 |
Report: PeakSpaceGainsMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.81 | 16-JAN-15:00 | 37.58 | 09-JAN-17:00 |
| February | 397.10 | 01-FEB-00:10 | 307.95 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.72 | 02-FEB-13:00 | 54.64 | 16-FEB-18:01 |
| March | 397.10 | 01-MAR-00:10 | 307.95 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.99 | 27-MAR-15:00 | 40.99 | 20-MAR-19:00 |
| April | 397.10 | 01-APR-00:10 | 307.95 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.23 | 28-APR-15:00 | 28.37 | 01-APR-17:55 |
| May | 397.10 | 01-MAY-00:10 | 307.95 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.60 | 25-MAY-14:00 | 5.94 | 19-MAY-18:53 |
| June | 397.10 | 01-JUN-00:10 | 307.95 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.28 | 08-JUN-15:00 | 10.07 | 06-JUN-20:55 |
| July | 397.10 | 01-JUL-00:10 | 307.95 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.33 | 19-JUL-13:00 | 7.04 | 31-JUL-11:00 |
| August | 397.10 | 01-AUG-00:10 | 307.95 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.84 | 20-AUG-14:00 | 10.22 | 25-AUG-24:00 |
| September | 397.10 | 01-SEP-00:10 | 307.95 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.46 | 09-SEP-17:00 | 10.34 | 19-SEP-19:00 |
| October | 397.10 | 01-OCT-00:10 | 307.95 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.39 | 09-OCT-14:00 | 20.56 | 27-OCT-07:00 |
| November | 397.10 | 01-NOV-00:10 | 307.95 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.39 | 28-NOV-13:00 | 26.67 | 12-NOV-07:01 |
| December | 397.10 | 01-DEC-00:10 | 307.95 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.67 | 13-DEC-14:20 | 38.00 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.81 | 5.94 | ||||
| Maximum of Months | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.33 | 54.64 |
Report: PeakSpaceGainsMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 | 190.19 | 01-JAN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.43 | 16-JAN-15:00 | 13604.77 | 21-JAN-07:01 |
| February | 397.10 | 01-FEB-00:10 | 307.95 | 01-FEB-00:10 | 190.19 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 109.02 | 02-FEB-13:00 | 15884.15 | 05-FEB-07:01 |
| March | 397.10 | 01-MAR-00:10 | 307.95 | 01-MAR-00:10 | 190.19 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 245.03 | 26-MAR-14:00 | 13462.31 | 09-MAR-07:01 |
| April | 397.10 | 01-APR-00:10 | 307.95 | 01-APR-00:10 | 190.19 | 01-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2195.14 | 28-APR-16:02 | 9126.81 | 11-APR-06:01 |
| May | 397.10 | 01-MAY-00:10 | 307.95 | 01-MAY-00:10 | 190.19 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2735.97 | 28-MAY-16:02 | 2627.51 | 02-MAY-06:01 |
| June | 397.10 | 01-JUN-00:10 | 307.95 | 01-JUN-00:10 | 190.19 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2835.96 | 10-JUN-16:02 | 2912.85 | 07-JUN-06:01 |
| July | 397.10 | 01-JUL-00:10 | 307.95 | 01-JUL-00:10 | 190.19 | 01-JUL-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3827.22 | 22-JUL-16:02 | 1914.57 | 12-JUL-16:02 |
| August | 397.10 | 01-AUG-00:10 | 307.95 | 01-AUG-00:10 | 190.19 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3951.93 | 30-AUG-16:02 | 2950.98 | 29-AUG-06:01 |
| September | 397.10 | 01-SEP-00:10 | 307.95 | 01-SEP-00:10 | 190.19 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3802.91 | 09-SEP-16:02 | 3374.45 | 07-SEP-16:02 |
| October | 397.10 | 01-OCT-00:10 | 307.95 | 01-OCT-00:10 | 190.19 | 01-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2046.09 | 05-OCT-16:02 | 8871.17 | 28-OCT-06:01 |
| November | 397.10 | 01-NOV-00:10 | 307.95 | 01-NOV-00:10 | 190.19 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 424.26 | 02-NOV-16:02 | 10664.83 | 12-NOV-07:01 |
| December | 397.10 | 01-DEC-00:10 | 307.95 | 01-DEC-00:10 | 190.19 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 208.25 | 13-DEC-15:00 | 13271.77 | 18-DEC-07:01 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 397.10 | 307.95 | 190.19 | 0.00 | 0.00 | 0.00 | 0.00 | 50.43 | 1914.57 | |||||
| Maximum of Months | 397.10 | 307.95 | 190.19 | 0.00 | 0.00 | 0.00 | 0.00 | 3951.93 | 15884.15 |
Report: PeakSpaceGainsMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.62 | 16-JAN-15:00 | 31.51 | 09-JAN-17:00 |
| February | 397.10 | 01-FEB-00:10 | 307.95 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.31 | 02-FEB-13:00 | 44.32 | 16-FEB-18:01 |
| March | 397.10 | 01-MAR-00:10 | 307.95 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.23 | 27-MAR-15:00 | 33.76 | 20-MAR-19:00 |
| April | 397.10 | 01-APR-00:10 | 307.95 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.82 | 28-APR-15:00 | 20.85 | 01-APR-21:00 |
| May | 397.10 | 01-MAY-00:10 | 307.95 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.81 | 25-MAY-14:00 | 4.01 | 05-MAY-06:00 |
| June | 397.10 | 01-JUN-00:10 | 307.95 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.25 | 08-JUN-15:00 | 6.91 | 06-JUN-20:55 |
| July | 397.10 | 01-JUL-00:10 | 307.95 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.61 | 19-JUL-13:00 | 4.97 | 31-JUL-11:00 |
| August | 397.10 | 01-AUG-00:10 | 307.95 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.38 | 20-AUG-14:00 | 7.70 | 25-AUG-24:00 |
| September | 397.10 | 01-SEP-00:10 | 307.95 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.37 | 09-SEP-17:00 | 6.98 | 19-SEP-19:00 |
| October | 397.10 | 01-OCT-00:10 | 307.95 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.59 | 09-OCT-14:00 | 17.01 | 27-OCT-07:00 |
| November | 397.10 | 01-NOV-00:10 | 307.95 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.81 | 03-NOV-14:00 | 22.02 | 12-NOV-08:00 |
| December | 397.10 | 01-DEC-00:10 | 307.95 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.88 | 13-DEC-14:30 | 35.51 | 20-DEC-01:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.62 | 4.01 | ||||
| Maximum of Months | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.61 | 44.32 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5304.74 | 15-JAN-18:02 | 1425.00 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.20 |
| February | 5248.65 | 09-FEB-18:42 | 1425.00 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.95 |
| March | 5203.67 | 04-MAR-22:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.02 |
| April | 5278.59 | 16-APR-20:42 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.12 |
| May | 4275.63 | 27-MAY-18:52 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.82 |
| June | 4062.21 | 06-JUN-20:12 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.43 |
| July | 4289.57 | 12-JUL-17:32 | 1425.00 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.06 |
| August | 4282.63 | 16-AUG-16:12 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.05 |
| September | 4505.65 | 06-SEP-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.34 |
| October | 5335.40 | 17-OCT-16:42 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.89 |
| November | 5299.00 | 30-NOV-22:22 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.80 |
| December | 5477.47 | 17-DEC-17:01 | 2375.00 | 548.21 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.95 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 4062.21 | 0.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.82 | |
| Maximum of Months | 5477.47 | 2375.00 | 548.21 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.95 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4777.06 | 02-JAN-22:12 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.68 |
| February | 4438.56 | 26-FEB-19:02 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.01 |
| March | 4917.84 | 04-MAR-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.41 |
| April | 5048.44 | 16-APR-20:42 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.14 |
| May | 4122.21 | 27-MAY-18:52 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.88 |
| June | 3876.52 | 06-JUN-20:12 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.65 |
| July | 4153.68 | 12-JUL-16:32 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 4044.27 | 16-AUG-16:12 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.11 |
| September | 4426.85 | 02-SEP-17:12 | 1239.75 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.82 |
| October | 5020.06 | 17-OCT-18:12 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.12 |
| November | 5050.10 | 30-NOV-22:22 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.00 |
| December | 5053.59 | 17-DEC-17:32 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.59 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3876.52 | 741.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5053.59 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.59 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 6680.28 | 03-JAN-07:01 | 0.00 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85.32 |
| February | 5054.04 | 24-FEB-07:01 | 0.00 | 805.72 | 1754.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 5613.00 | 01-MAR-07:01 | 0.00 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38.34 |
| April | 5683.69 | 18-APR-06:01 | 0.00 | 716.20 | 1559.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.76 |
| May | 4694.85 | 12-MAY-06:01 | 0.00 | 805.72 | 1754.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.01 |
| June | 4849.25 | 07-JUN-06:01 | 0.00 | 716.20 | 1559.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.16 |
| July | 3957.76 | 17-JUL-06:01 | 0.00 | 716.20 | 1559.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.95 |
| August | 4245.40 | 04-AUG-06:01 | 0.00 | 805.72 | 1754.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.98 |
| September | 4623.92 | 22-SEP-06:01 | 0.00 | 805.72 | 1754.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.25 |
| October | 6601.57 | 17-OCT-06:01 | 0.00 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59.99 |
| November | 6492.84 | 14-NOV-07:01 | 0.00 | 805.72 | 1754.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50.82 |
| December | 6596.43 | 18-DEC-07:01 | 0.00 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 54.83 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3957.76 | 0.00 | 716.20 | 1559.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 6680.28 | 0.00 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85.32 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4509.98 | 02-JAN-22:12 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.64 |
| February | 3991.84 | 27-FEB-18:42 | 1239.75 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.06 |
| March | 4639.84 | 19-MAR-18:22 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 75.42 |
| April | 4748.80 | 16-APR-20:42 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.64 |
| May | 3937.92 | 13-MAY-12:52 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.51 |
| June | 3716.56 | 01-JUN-14:02 | 356.25 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 4.31 | 0.00 |
| July | 3792.24 | 12-JUL-15:42 | 427.50 | 230.24 | 2825.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.15 |
| August | 3815.23 | 16-AUG-16:12 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.17 |
| September | 4101.17 | 02-SEP-17:12 | 1239.75 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.08 |
| October | 4765.33 | 17-OCT-18:12 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.72 |
| November | 4771.93 | 30-NOV-22:22 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.81 |
| December | 4765.05 | 01-DEC-17:12 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.77 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3716.56 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4771.93 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 4.31 | 75.42 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4084.58 | 02-JAN-22:12 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.01 |
| February | 3576.84 | 26-FEB-19:02 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.12 |
| March | 4221.14 | 04-MAR-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.63 |
| April | 4301.76 | 16-APR-20:42 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.63 |
| May | 3430.80 | 13-MAY-12:52 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.15 |
| June | 3265.44 | 06-JUN-20:12 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.46 |
| July | 3275.87 | 12-JUL-15:42 | 427.50 | 230.24 | 2825.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.72 |
| August | 3360.60 | 16-AUG-16:12 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.58 |
| September | 3576.68 | 06-SEP-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.65 |
| October | 4289.86 | 17-OCT-18:12 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.48 |
| November | 4317.95 | 30-NOV-22:22 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.90 |
| December | 4318.72 | 17-DEC-17:32 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.32 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3265.44 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.15 | |
| Maximum of Months | 4318.72 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.32 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4078.67 | 02-JAN-22:12 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.01 |
| February | 3569.12 | 26-FEB-19:02 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.12 |
| March | 4213.90 | 04-MAR-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.61 |
| April | 4295.77 | 16-APR-20:42 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.62 |
| May | 3429.14 | 13-MAY-12:52 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.15 |
| June | 3260.50 | 01-JUN-14:02 | 356.25 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 2.57 | 0.00 |
| July | 3273.19 | 12-JUL-15:42 | 427.50 | 230.24 | 2825.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.72 |
| August | 3356.20 | 16-AUG-16:12 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.58 |
| September | 3570.83 | 06-SEP-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.66 |
| October | 4283.79 | 17-OCT-18:12 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.48 |
| November | 4312.54 | 30-NOV-22:22 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.89 |
| December | 4312.98 | 17-DEC-17:32 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.29 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3260.50 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4312.98 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 2.57 | 31.29 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4653.75 | 28-JAN-20:12 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.32 |
| February | 4620.75 | 08-FEB-21:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 4566.95 | 04-MAR-22:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.28 |
| April | 4628.66 | 16-APR-20:42 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.77 |
| May | 3661.87 | 13-MAY-21:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 |
| June | 3527.82 | 06-JUN-20:12 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.26 |
| July | 3608.45 | 12-JUL-15:32 | 0.00 | 230.24 | 2825.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.54 |
| August | 3667.28 | 16-AUG-16:12 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.53 |
| September | 3873.41 | 06-SEP-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.58 |
| October | 4647.10 | 28-OCT-21:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.33 |
| November | 4649.43 | 30-NOV-22:22 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.32 |
| December | 4692.88 | 17-DEC-17:22 | 1425.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.45 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3527.82 | 0.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4692.88 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.45 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4688.06 | 28-JAN-20:12 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.28 |
| February | 4654.36 | 08-FEB-21:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 4604.15 | 04-MAR-22:02 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.31 |
| April | 4668.80 | 16-APR-20:42 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.81 |
| May | 3758.68 | 13-MAY-21:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.09 |
| June | 3609.60 | 06-JUN-20:12 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.17 |
| July | 3697.80 | 12-JUL-15:32 | 0.00 | 230.24 | 2825.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.53 |
| August | 3739.41 | 16-AUG-16:12 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.52 |
| September | 3932.13 | 06-SEP-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.57 |
| October | 4688.87 | 17-OCT-16:42 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.32 |
| November | 4689.59 | 30-NOV-22:22 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.32 |
| December | 4830.05 | 17-DEC-17:01 | 2375.00 | 548.21 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.89 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3609.60 | 0.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4830.05 | 2375.00 | 548.21 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.89 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5777.99 | 15-JAN-18:02 | 1425.00 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43.38 |
| February | 5753.15 | 19-FEB-18:32 | 1425.00 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.03 |
| March | 5726.96 | 15-MAR-14:32 | 0.00 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.39 |
| April | 5756.31 | 02-APR-20:12 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.80 |
| May | 4706.95 | 27-MAY-18:52 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.09 |
| June | 4399.14 | 06-JUN-20:12 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.78 |
| July | 4656.66 | 12-JUL-17:32 | 1425.00 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.46 |
| August | 4558.63 | 16-AUG-16:12 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.75 |
| September | 4853.37 | 06-SEP-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.14 |
| October | 5786.45 | 17-OCT-16:42 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.48 |
| November | 5775.24 | 21-NOV-17:01 | 0.00 | 383.74 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.16 |
| December | 5963.39 | 17-DEC-17:01 | 2375.00 | 548.21 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 77.31 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 4399.14 | 0.00 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.09 | |
| Maximum of Months | 5963.39 | 2375.00 | 548.21 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 77.31 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5206.39 | 02-JAN-22:12 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39.48 |
| February | 4958.46 | 25-FEB-19:42 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.53 |
| March | 5466.75 | 04-MAR-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.75 |
| April | 5542.17 | 16-APR-20:42 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.30 |
| May | 4539.00 | 27-MAY-18:52 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.19 |
| June | 4195.20 | 06-JUN-20:12 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.11 |
| July | 4513.28 | 12-JUL-16:32 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 4315.15 | 16-AUG-16:12 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.84 |
| September | 4668.49 | 02-SEP-17:12 | 1239.75 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.47 |
| October | 5476.39 | 17-OCT-15:11 | 498.75 | 268.61 | 3296.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.54 |
| November | 5495.34 | 19-NOV-18:12 | 1239.75 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 5480.46 | 01-DEC-17:12 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.68 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 4195.20 | 498.75 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5542.17 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39.48 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5415.79 | 28-JAN-20:12 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.56 |
| February | 5398.77 | 19-FEB-18:32 | 1425.00 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.60 |
| March | 5380.13 | 15-MAR-14:32 | 0.00 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.74 |
| April | 5426.44 | 16-APR-20:42 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.55 |
| May | 4494.43 | 13-MAY-12:52 | 712.50 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.91 |
| June | 4165.60 | 01-JUN-14:02 | 0.00 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 6.25 | 0.00 |
| July | 4315.97 | 12-JUL-15:32 | 0.00 | 230.24 | 2825.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.53 |
| August | 4274.54 | 16-AUG-16:12 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.85 |
| September | 4497.07 | 06-SEP-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.38 |
| October | 5393.95 | 28-OCT-21:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.58 |
| November | 5432.20 | 21-NOV-17:01 | 0.00 | 383.74 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.52 |
| December | 5466.35 | 17-DEC-13:42 | 712.50 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.38 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 4165.60 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5466.35 | 1425.00 | 526.29 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 6.25 | 63.38 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4856.72 | 02-JAN-22:12 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39.43 |
| February | 4509.55 | 26-FEB-19:02 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.85 |
| March | 5106.21 | 04-MAR-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.76 |
| April | 5187.65 | 16-APR-20:42 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.48 |
| May | 4313.40 | 13-MAY-12:52 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.97 |
| June | 3959.20 | 01-JUN-14:02 | 356.25 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 6.21 | 0.00 |
| July | 4052.70 | 12-JUL-15:42 | 427.50 | 230.24 | 2825.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.63 |
| August | 4025.20 | 16-AUG-16:12 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.95 |
| September | 4271.06 | 06-SEP-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.50 |
| October | 5108.83 | 17-OCT-15:11 | 498.75 | 268.61 | 3296.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.61 |
| November | 5127.74 | 30-NOV-22:22 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.45 |
| December | 5109.18 | 17-DEC-17:32 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.38 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3959.20 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5187.65 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 6.21 | 72.38 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4671.88 | 28-JAN-20:12 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.65 |
| February | 4657.88 | 08-FEB-21:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 4666.92 | 04-MAR-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.81 |
| April | 4725.20 | 16-APR-20:42 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.05 |
| May | 3778.61 | 13-MAY-12:52 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.18 |
| June | 3518.61 | 01-JUN-14:02 | 356.25 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 3.73 | 0.00 |
| July | 3510.79 | 12-JUL-15:42 | 427.50 | 230.24 | 2825.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.02 |
| August | 3570.37 | 16-AUG-16:12 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.67 |
| September | 3846.25 | 06-SEP-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.08 |
| October | 4653.16 | 17-OCT-16:32 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.66 |
| November | 4697.45 | 30-NOV-22:22 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.37 |
| December | 4685.97 | 17-DEC-17:32 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.28 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3510.79 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4725.20 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 3.73 | 44.28 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4665.45 | 28-JAN-20:12 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.66 |
| February | 4651.10 | 08-FEB-21:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 4659.62 | 04-MAR-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.77 |
| April | 4717.68 | 16-APR-20:42 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.04 |
| May | 3775.93 | 13-MAY-12:52 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.19 |
| June | 3516.60 | 01-JUN-14:02 | 356.25 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 3.72 | 0.00 |
| July | 3507.13 | 12-JUL-15:42 | 427.50 | 230.24 | 2825.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.02 |
| August | 3564.62 | 16-AUG-16:12 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.67 |
| September | 3837.76 | 06-SEP-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.06 |
| October | 4646.25 | 17-OCT-16:32 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.67 |
| November | 4690.12 | 30-NOV-22:22 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.34 |
| December | 4678.67 | 17-DEC-17:32 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.25 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3507.13 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4717.68 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 3.72 | 44.25 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5002.40 | 15-JAN-18:02 | 1425.00 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.51 |
| February | 4990.85 | 08-FEB-21:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 4947.17 | 14-MAR-20:12 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 5000.32 | 16-APR-20:42 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.05 |
| May | 3986.73 | 13-MAY-21:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.42 |
| June | 3727.41 | 01-JUN-14:02 | 0.00 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 3.79 | 0.00 |
| July | 3788.26 | 12-JUL-15:32 | 0.00 | 230.24 | 2825.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.20 |
| August | 3852.28 | 16-AUG-16:12 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.61 |
| September | 4112.45 | 06-SEP-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.17 |
| October | 4987.15 | 28-OCT-21:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.75 |
| November | 4997.89 | 21-NOV-17:01 | 0.00 | 383.74 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.80 |
| December | 5133.98 | 17-DEC-17:01 | 2375.00 | 548.21 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.78 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3727.41 | 0.00 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5133.98 | 2375.00 | 548.21 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 3.79 | 45.78 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4996.35 | 28-JAN-20:12 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.17 |
| February | 4984.74 | 08-FEB-21:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 4941.96 | 14-MAR-20:12 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 4993.12 | 16-APR-20:42 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.05 |
| May | 3982.42 | 13-MAY-21:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.42 |
| June | 3726.33 | 01-JUN-14:02 | 0.00 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 3.79 | 0.00 |
| July | 3785.42 | 12-JUL-15:32 | 0.00 | 230.24 | 2825.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.20 |
| August | 3847.13 | 16-AUG-16:12 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.61 |
| September | 4105.45 | 06-SEP-20:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.18 |
| October | 4980.69 | 28-OCT-21:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.73 |
| November | 4991.96 | 21-NOV-17:01 | 0.00 | 383.74 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.81 |
| December | 5127.52 | 17-DEC-17:01 | 2375.00 | 548.21 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.77 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3726.33 | 0.00 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5127.52 | 2375.00 | 548.21 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 3.79 | 45.77 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 6354.23 | 29-JAN-15:42 | 0.00 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.19 |
| February | 6278.79 | 10-FEB-16:22 | 0.00 | 230.24 | 2825.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.90 |
| March | 6391.88 | 16-MAR-16:12 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.26 |
| April | 6456.37 | 12-APR-16:42 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 37.32 |
| May | 5270.22 | 27-MAY-18:52 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.50 |
| June | 4805.53 | 01-JUN-14:02 | 0.00 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 8.33 | 0.00 |
| July | 5718.72 | 12-JUL-16:22 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 5398.88 | 16-AUG-15:52 | 0.00 | 191.87 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.36 |
| September | 5764.51 | 02-SEP-16:42 | 1187.50 | 274.10 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.39 |
| October | 6337.15 | 17-OCT-16:42 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.31 |
| November | 6375.12 | 26-NOV-18:02 | 1425.00 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.22 |
| December | 6547.25 | 17-DEC-17:01 | 2375.00 | 548.21 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 108.10 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 4805.53 | 0.00 | 115.13 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 6547.25 | 2375.00 | 548.21 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 8.33 | 108.10 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5716.04 | 02-JAN-22:12 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.75 |
| February | 5679.95 | 27-FEB-18:22 | 1239.75 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.00 |
| March | 6028.86 | 14-MAR-20:12 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 6209.00 | 16-APR-16:32 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68.36 |
| May | 5140.38 | 27-MAY-18:52 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.59 |
| June | 4653.49 | 01-JUN-14:02 | 356.25 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 8.27 | 0.00 |
| July | 5548.35 | 12-JUL-16:32 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 5169.67 | 16-AUG-15:52 | 356.25 | 191.87 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.23 |
| September | 5610.73 | 02-SEP-17:12 | 1239.75 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.03 |
| October | 6080.79 | 17-OCT-16:12 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.25 |
| November | 6089.21 | 30-NOV-15:21 | 415.63 | 134.32 | 2801.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.17 |
| December | 6035.65 | 01-DEC-17:12 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.89 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 4653.49 | 356.25 | 115.13 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 6209.00 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 8.27 | 68.36 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5787.35 | 29-JAN-15:42 | 0.00 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.10 |
| February | 5741.49 | 08-FEB-13:32 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.00 |
| March | 5808.00 | 16-MAR-16:12 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39.22 |
| April | 5817.73 | 12-APR-16:42 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.20 |
| May | 4848.49 | 13-MAY-12:52 | 712.50 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.35 |
| June | 4497.79 | 01-JUN-14:02 | 0.00 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 8.30 | 0.00 |
| July | 5136.86 | 12-JUL-15:12 | 0.00 | 230.24 | 2825.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.25 |
| August | 4906.34 | 16-AUG-15:52 | 0.00 | 191.87 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.21 |
| September | 5114.22 | 02-SEP-16:42 | 1187.50 | 274.10 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.98 |
| October | 5848.63 | 17-OCT-16:42 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.40 |
| November | 5837.82 | 21-NOV-12:22 | 0.00 | 65.78 | 2436.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.47 |
| December | 5942.73 | 17-DEC-17:01 | 2375.00 | 548.21 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 103.99 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 4497.79 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5942.73 | 2375.00 | 548.21 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 8.30 | 103.99 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5189.48 | 02-JAN-22:12 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
| February | 4869.68 | 26-FEB-19:02 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.81 |
| March | 5523.51 | 24-MAR-13:42 | 356.25 | 65.78 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.05 |
| April | 5619.40 | 16-APR-16:32 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 62.14 |
| May | 4704.32 | 13-MAY-12:52 | 356.25 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.39 |
| June | 4368.51 | 01-JUN-14:02 | 356.25 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 8.29 | 0.00 |
| July | 4997.03 | 12-JUL-16:32 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 4680.80 | 16-AUG-15:52 | 356.25 | 191.87 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.08 |
| September | 4977.59 | 02-SEP-17:12 | 1239.75 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.08 |
| October | 5503.15 | 17-OCT-15:11 | 498.75 | 268.61 | 3296.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.08 |
| November | 5524.00 | 30-NOV-15:21 | 415.63 | 134.32 | 2801.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.23 |
| December | 5502.18 | 01-DEC-17:12 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.11 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 4368.51 | 356.25 | 65.78 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5619.40 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 8.29 | 62.14 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4918.60 | 02-JAN-22:12 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.29 |
| February | 4566.92 | 25-FEB-19:42 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.72 |
| March | 5146.88 | 04-MAR-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.07 |
| April | 5236.66 | 16-APR-16:32 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.31 |
| May | 4286.28 | 27-MAY-18:52 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.22 |
| June | 3939.32 | 01-JUN-14:02 | 356.25 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 4.90 | 0.00 |
| July | 4500.03 | 12-JUL-16:32 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 4189.12 | 16-AUG-17:22 | 1033.12 | 370.05 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.98 |
| September | 4525.46 | 02-SEP-17:12 | 1239.75 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.96 |
| October | 5149.81 | 17-OCT-15:11 | 498.75 | 268.61 | 3296.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.28 |
| November | 5177.20 | 19-NOV-18:12 | 1239.75 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 5155.80 | 01-DEC-17:12 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.49 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3939.32 | 356.25 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5236.66 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 4.90 | 36.31 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4898.70 | 02-JAN-22:12 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.27 |
| February | 4543.21 | 25-FEB-19:42 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.72 |
| March | 5127.12 | 04-MAR-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.95 |
| April | 5219.63 | 16-APR-16:32 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.39 |
| May | 4268.15 | 27-MAY-18:52 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.22 |
| June | 3928.61 | 01-JUN-14:02 | 356.25 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 4.90 | 0.00 |
| July | 4481.69 | 12-JUL-16:32 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 4172.76 | 16-AUG-15:52 | 356.25 | 191.87 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.25 |
| September | 4504.59 | 02-SEP-17:12 | 1239.75 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.91 |
| October | 5131.48 | 17-OCT-15:11 | 498.75 | 268.61 | 3296.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.28 |
| November | 5154.04 | 19-NOV-18:12 | 1239.75 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 5141.62 | 01-DEC-17:12 | 741.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.51 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3928.61 | 356.25 | 115.13 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5219.63 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 4.90 | 36.39 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5427.23 | 15-JAN-16:42 | 1425.00 | 230.24 | 2825.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.03 |
| February | 5399.26 | 19-FEB-18:32 | 1425.00 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.73 |
| March | 5427.95 | 15-MAR-16:32 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.10 |
| April | 5443.28 | 02-APR-18:12 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48.57 |
| May | 4433.58 | 27-MAY-18:52 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.15 |
| June | 4117.49 | 06-JUN-20:12 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.15 |
| July | 4634.48 | 12-JUL-15:12 | 0.00 | 230.24 | 2825.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.31 |
| August | 4485.77 | 16-AUG-15:52 | 0.00 | 191.87 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.32 |
| September | 4585.43 | 02-SEP-17:52 | 1425.00 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.20 |
| October | 5511.06 | 17-OCT-16:42 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.61 |
| November | 5481.04 | 26-NOV-18:02 | 1425.00 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.66 |
| December | 5610.77 | 17-DEC-17:01 | 2375.00 | 548.21 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.74 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 4117.49 | 0.00 | 191.87 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.15 | |
| Maximum of Months | 5610.77 | 2375.00 | 548.21 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.74 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5408.75 | 15-JAN-16:42 | 1425.00 | 230.24 | 2825.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.97 |
| February | 5381.96 | 19-FEB-18:32 | 1425.00 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.74 |
| March | 5410.84 | 15-MAR-16:32 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.19 |
| April | 5424.86 | 02-APR-18:12 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48.50 |
| May | 4415.51 | 27-MAY-18:52 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.15 |
| June | 4101.16 | 06-JUN-20:12 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.19 |
| July | 4622.27 | 12-JUL-15:12 | 0.00 | 230.24 | 2825.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.33 |
| August | 4470.01 | 16-AUG-15:52 | 0.00 | 191.87 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.32 |
| September | 4563.75 | 02-SEP-17:52 | 1425.00 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.14 |
| October | 5489.16 | 17-OCT-16:42 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.52 |
| November | 5463.00 | 21-NOV-12:22 | 0.00 | 65.78 | 2436.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.21 |
| December | 5591.01 | 17-DEC-17:01 | 2375.00 | 548.21 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.68 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 4101.16 | 0.00 | 65.78 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.15 | |
| Maximum of Months | 5591.01 | 2375.00 | 548.21 | 5886.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.68 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.51 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.92 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.28 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.38 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.30 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.10 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.59 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.70 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.11 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.23 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.43 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.84 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.11 | |
| Maximum of Months | 0.00 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.84 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.23 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.95 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.65 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.87 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.63 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.84 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.68 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.05 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.14 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.23 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.35 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.19 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.14 | |
| Maximum of Months | 0.00 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.23 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.60 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.31 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.90 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.94 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.85 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.85 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.38 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.51 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.08 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.27 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.70 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.02 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.08 | |
| Maximum of Months | 0.00 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.02 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
| January | 0.615788E+11 | 52351.28 | 19-JAN-11:30 | 0.340912E+11 | 24157.89 | 26-JAN-07:00 |
| February | 0.573808E+11 | 51263.68 | 24-FEB-11:39 | 0.305397E+11 | 24129.41 | 05-FEB-07:40 |
| March | 0.644522E+11 | 50453.22 | 26-MAR-16:19 | 0.325931E+11 | 23602.55 | 01-MAR-07:40 |
| April | 0.701845E+11 | 51964.01 | 24-APR-11:00 | 0.296719E+11 | 22841.90 | 02-APR-06:40 |
| May | 0.918600E+11 | 51432.45 | 19-MAY-20:30 | 0.285749E+11 | 21069.55 | 01-MAY-06:49 |
| June | 0.919202E+11 | 52966.72 | 28-JUN-16:40 | 0.260492E+11 | 19316.92 | 01-JUN-06:30 |
| July | 0.978289E+11 | 56402.66 | 14-JUL-16:30 | 0.261069E+11 | 18944.73 | 04-JUL-06:49 |
| August | 0.970023E+11 | 55492.11 | 16-AUG-16:19 | 0.263677E+11 | 19111.21 | 31-AUG-06:49 |
| September | 0.900254E+11 | 57461.20 | 10-SEP-16:10 | 0.267337E+11 | 20563.34 | 29-SEP-06:19 |
| October | 0.873798E+11 | 55387.00 | 08-OCT-16:10 | 0.295396E+11 | 21553.60 | 31-OCT-06:00 |
| November | 0.679503E+11 | 54208.38 | 29-NOV-11:00 | 0.306015E+11 | 23300.39 | 30-NOV-07:00 |
| December | 0.652484E+11 | 49921.38 | 16-DEC-10:39 | 0.332830E+11 | 23808.32 | 30-DEC-07:19 |
| Annual Sum or Average | 0.942812E+12 | 0.354152E+12 | ||||
| Minimum of Months | 0.573808E+11 | 49921.38 | 0.260492E+11 | 18944.73 | ||
| Maximum of Months | 0.978289E+11 | 57461.20 | 0.340912E+11 | 24157.89 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [J] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [J] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
| January | 0.618562E+10 | 0.317171E+10 | 0.385428E+11 | 0.00 | 0.664413E+10 | 38818862.27 | 0.629165E+09 | 0.636649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.559770E+10 | 0.273932E+10 | 0.348258E+11 | 0.00 | 0.638837E+10 | 35062198.18 | 0.419137E+09 | 0.737538E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.621989E+10 | 0.284395E+10 | 0.385844E+11 | 0.00 | 0.730309E+10 | 38818862.27 | 0.201774E+09 | 0.926029E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.599345E+10 | 0.256914E+10 | 0.373085E+11 | 0.00 | 0.870319E+10 | 37566640.91 | 0.00 | 0.155727E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.620847E+10 | 0.248972E+10 | 0.385705E+11 | 0.00 | 0.127626E+11 | 38818862.27 | 0.00 | 0.317899E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.601630E+10 | 0.231954E+10 | 0.373361E+11 | 0.00 | 0.129073E+11 | 37566640.91 | 0.00 | 0.333034E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.618562E+10 | 0.244434E+10 | 0.385428E+11 | 0.00 | 0.138739E+11 | 38818862.27 | 0.00 | 0.367433E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.621989E+10 | 0.257796E+10 | 0.385844E+11 | 0.00 | 0.136735E+11 | 38818862.27 | 0.00 | 0.359078E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.599345E+10 | 0.267503E+10 | 0.373085E+11 | 0.00 | 0.125316E+11 | 37566640.91 | 0.00 | 0.314793E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.619704E+10 | 0.295615E+10 | 0.385567E+11 | 0.00 | 0.118113E+11 | 38818862.27 | 0.00 | 0.278198E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.599345E+10 | 0.302044E+10 | 0.373085E+11 | 0.00 | 0.815066E+10 | 37566640.91 | 5633276.21 | 0.134341E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.618562E+10 | 0.321332E+10 | 0.385428E+11 | 0.00 | 0.739279E+10 | 38818862.27 | 0.383148E+09 | 0.949192E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.729965E+11 | 0.330206E+11 | 0.454012E+12 | 0.00 | 0.122142E+12 | 0.457061E+09 | 0.163886E+10 | 0.258544E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.559770E+10 | 0.231954E+10 | 0.348258E+11 | 0.00 | 0.638837E+10 | 35062198.18 | 0.00 | 0.636649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.621989E+10 | 0.321332E+10 | 0.385844E+11 | 0.00 | 0.138739E+11 | 38818862.27 | 0.629165E+09 | 0.367433E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [J] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.340912E+11 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.305397E+11 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.325931E+11 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.296719E+11 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.285749E+11 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.260492E+11 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.261069E+11 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.263677E+11 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.267337E+11 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.295396E+11 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.306015E+11 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.332830E+11 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.354152E+12 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.260492E+11 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.340912E+11 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY {Maximum} [W] | PUMPS:ELECTRICITY {TIMESTAMP} | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
| January | 4040.47 | 01-JAN-19:10 | 2101.03 | 01-JAN-00:10 | 22246.15 | 03-JAN-17:10 | 0.00 | 8111.21 | 19-JAN-11:30 | 14.49 | 01-JAN-06:10 | 4868.77 | 05-JAN-05:00 |
| February | 4040.47 | 01-FEB-19:10 | 2101.03 | 01-FEB-00:10 | 22246.15 | 01-FEB-17:10 | 0.00 | 7991.23 | 24-FEB-11:39 | 14.49 | 01-FEB-06:10 | 5133.41 | 05-FEB-06:00 |
| March | 4040.47 | 01-MAR-19:10 | 2101.03 | 01-MAR-00:10 | 22246.15 | 01-MAR-17:10 | 0.00 | 7772.36 | 29-MAR-12:00 | 14.49 | 01-MAR-06:10 | 2697.27 | 09-MAR-06:49 |
| April | 4040.47 | 01-APR-18:10 | 2101.03 | 01-APR-00:10 | 22246.15 | 03-APR-16:10 | 0.00 | 8051.27 | 24-APR-11:00 | 14.49 | 01-APR-06:19 | 0.00 | 01-APR-00:10 |
| May | 4040.47 | 01-MAY-18:10 | 2101.03 | 01-MAY-00:10 | 22246.15 | 01-MAY-16:10 | 0.00 | 7875.17 | 15-MAY-07:30 | 14.49 | 01-MAY-17:10 | 0.00 | 01-MAY-00:10 |
| June | 4040.47 | 01-JUN-18:10 | 2101.03 | 01-JUN-00:10 | 22246.15 | 01-JUN-16:10 | 0.00 | 7840.65 | 06-JUN-07:49 | 14.49 | 01-JUN-06:19 | 0.00 | 01-JUN-00:10 |
| July | 4040.47 | 01-JUL-18:10 | 2101.03 | 01-JUL-00:10 | 22246.15 | 03-JUL-16:10 | 0.00 | 7878.53 | 14-JUL-16:30 | 14.49 | 03-JUL-07:19 | 0.00 | 01-JUL-00:10 |
| August | 4040.47 | 01-AUG-18:10 | 2101.03 | 01-AUG-00:10 | 22246.15 | 01-AUG-16:10 | 0.00 | 8452.05 | 29-AUG-08:09 | 14.49 | 01-AUG-17:19 | 0.00 | 01-AUG-00:10 |
| September | 4040.47 | 01-SEP-18:10 | 2101.03 | 01-SEP-00:10 | 22246.15 | 01-SEP-16:10 | 0.00 | 8952.52 | 05-SEP-08:50 | 14.49 | 01-SEP-05:49 | 0.00 | 01-SEP-00:10 |
| October | 4040.47 | 01-OCT-18:10 | 2101.03 | 01-OCT-00:10 | 22246.15 | 02-OCT-16:10 | 0.00 | 8632.47 | 22-OCT-09:09 | 14.49 | 01-OCT-06:19 | 0.00 | 01-OCT-00:10 |
| November | 4040.47 | 01-NOV-18:10 | 2101.03 | 01-NOV-00:10 | 22246.15 | 01-NOV-16:10 | 0.00 | 8661.94 | 29-NOV-11:00 | 14.49 | 01-NOV-05:19 | 332.70 | 16-NOV-05:00 |
| December | 4040.47 | 01-DEC-19:10 | 2101.03 | 01-DEC-00:10 | 22246.15 | 01-DEC-17:10 | 0.00 | 8265.16 | 16-DEC-10:39 | 14.49 | 01-DEC-07:10 | 4832.56 | 21-DEC-06:00 |
| Annual Sum or Average | 0.00 | ||||||||||||
| Minimum of Months | 4040.47 | 2101.03 | 22246.15 | 0.00 | 7772.36 | 14.49 | 0.00 | ||||||
| Maximum of Months | 4040.47 | 2101.03 | 22246.15 | 0.00 | 8952.52 | 14.49 | 5133.41 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY {Maximum} [W] | HEATRECOVERY:ELECTRICITY {TIMESTAMP} | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
| January | 25106.46 | 19-JAN-11:30 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 24138.97 | 22-FEB-12:30 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 23486.52 | 29-MAR-12:00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 26374.39 | 24-APR-11:00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 24510.84 | 15-MAY-07:30 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 23680.70 | 06-JUN-07:49 | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 23837.18 | 13-JUL-14:39 | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 26651.47 | 29-AUG-08:09 | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 28765.14 | 05-SEP-08:50 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 26517.27 | 22-OCT-09:09 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 27903.60 | 29-NOV-12:00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 24809.78 | 16-DEC-10:39 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 23486.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Maximum of Months | 28765.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
| January | 52351.28 | 19-JAN-11:30 | 2019.26 | 17099.85 | 0.00 | 0.00 | 8111.21 | 14.49 | 0.00 | 25106.46 | 0.00 |
| February | 51263.68 | 24-FEB-11:39 | 2019.26 | 17099.85 | 0.00 | 0.00 | 7991.23 | 14.49 | 0.00 | 24138.84 | 0.00 |
| March | 50453.22 | 26-MAR-16:19 | 3020.75 | 22179.86 | 0.00 | 0.00 | 6677.65 | 14.49 | 0.00 | 18560.48 | 0.00 |
| April | 51964.01 | 24-APR-11:00 | 1969.53 | 15554.33 | 0.00 | 0.00 | 8051.27 | 14.49 | 0.00 | 26374.39 | 0.00 |
| May | 51432.45 | 19-MAY-20:30 | 3190.75 | 17257.79 | 2101.03 | 0.00 | 7497.25 | 14.49 | 0.00 | 21371.13 | 0.00 |
| June | 52966.72 | 28-JUN-16:40 | 3020.75 | 22246.15 | 0.00 | 0.00 | 6762.64 | 14.49 | 0.00 | 20922.69 | 0.00 |
| July | 56402.66 | 14-JUL-16:30 | 3020.75 | 22246.15 | 0.00 | 0.00 | 7878.53 | 14.49 | 0.00 | 23242.74 | 0.00 |
| August | 55492.11 | 16-AUG-16:19 | 3020.75 | 22246.15 | 0.00 | 0.00 | 7784.20 | 14.49 | 0.00 | 22426.53 | 0.00 |
| September | 57461.20 | 10-SEP-16:10 | 3020.75 | 22179.86 | 0.00 | 0.00 | 7577.09 | 14.49 | 0.00 | 24669.01 | 0.00 |
| October | 55387.00 | 08-OCT-16:10 | 3020.75 | 22179.86 | 0.00 | 0.00 | 7342.03 | 14.49 | 0.00 | 22829.87 | 0.00 |
| November | 54208.38 | 29-NOV-11:00 | 2019.26 | 17099.85 | 0.00 | 0.00 | 8661.94 | 14.49 | 0.00 | 26412.83 | 0.00 |
| December | 49921.38 | 16-DEC-10:39 | 1661.16 | 15170.79 | 0.00 | 0.00 | 8265.16 | 14.49 | 0.00 | 24809.78 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | |||||||||
| Minimum of Months | 49921.38 | 1661.16 | 15170.79 | 0.00 | 0.00 | 6677.65 | 14.49 | 0.00 | 18560.48 | 0.00 | |
| Maximum of Months | 57461.20 | 3190.75 | 22246.15 | 2101.03 | 0.00 | 8661.94 | 14.49 | 0.00 | 26412.83 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS {Maximum} [W] | WATERSYSTEMS:NATURALGAS {TIMESTAMP} | COGENERATION:NATURALGAS [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 24157.89 | 26-JAN-07:00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 24129.41 | 05-FEB-07:40 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 23602.55 | 01-MAR-07:40 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 22841.90 | 02-APR-06:40 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 21069.55 | 01-MAY-06:49 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 19316.92 | 01-JUN-06:30 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 18944.73 | 04-JUL-06:49 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 19111.21 | 31-AUG-06:49 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 20563.34 | 29-SEP-06:19 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 21553.60 | 31-OCT-06:00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 23300.39 | 30-NOV-07:00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 23808.32 | 30-DEC-07:19 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 18944.73 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 24157.89 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.63 | 0.00 | 24.63 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 3.83 | 25.05 | 0.00 | 25.05 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 4.17 | 25.24 | 0.00 | 25.24 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 5.33 | 25.52 | 0.00 | 25.52 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 25.46 | 0.00 | 25.46 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 5.00 | 25.31 | 0.00 | 25.31 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 25.38 | 0.00 | 25.38 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 24.82 | 0.00 | 24.82 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.76 | 0.00 | 24.76 |
| Annual Sum or Average | 0.00 | 0.00 | 29.33 | 25.30 | 0.00 | 25.30 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 25.52 | 0.00 | 25.52 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 240.50 | 23.85 | 201.50 | 24.23 | 24.17 | 24.26 |
| February | 169.83 | 23.59 | 235.67 | 24.14 | 11.67 | 24.15 |
| March | 222.83 | 23.58 | 235.50 | 24.05 | 36.17 | 24.11 |
| April | 71.50 | 24.78 | 395.67 | 24.53 | 58.00 | 24.57 |
| May | 112.33 | 24.39 | 515.00 | 24.17 | 112.33 | 24.20 |
| June | 63.50 | 24.33 | 492.00 | 24.09 | 63.50 | 24.12 |
| July | 60.00 | 24.21 | 533.00 | 24.05 | 60.00 | 24.06 |
| August | 28.83 | 25.41 | 506.00 | 24.19 | 28.83 | 24.25 |
| September | 50.83 | 25.48 | 510.00 | 24.34 | 50.83 | 24.44 |
| October | 41.17 | 25.08 | 489.17 | 24.40 | 37.33 | 24.45 |
| November | 33.17 | 24.82 | 375.33 | 24.65 | 16.33 | 24.69 |
| December | 137.83 | 23.95 | 272.00 | 24.46 | 17.33 | 24.50 |
| Annual Sum or Average | 1232.33 | 24.09 | 4760.83 | 24.26 | 516.50 | 24.30 |
| Minimum of Months | 28.83 | 23.58 | 201.50 | 24.05 | 11.67 | 24.06 |
| Maximum of Months | 240.50 | 25.48 | 533.00 | 24.65 | 112.33 | 24.69 |
Report: ComfortReportSimple55Monthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 566.17 | 23.31 | 205.67 | 23.62 | 66.33 | 23.69 |
| February | 446.17 | 23.24 | 290.33 | 23.68 | 93.17 | 23.76 |
| March | 441.67 | 23.45 | 280.00 | 23.82 | 94.00 | 23.92 |
| April | 164.83 | 24.52 | 541.50 | 24.47 | 111.83 | 24.52 |
| May | 138.67 | 24.38 | 744.00 | 24.14 | 138.67 | 24.18 |
| June | 65.33 | 24.47 | 720.00 | 24.09 | 65.33 | 24.12 |
| July | 64.17 | 24.42 | 744.00 | 24.08 | 64.17 | 24.10 |
| August | 39.83 | 25.24 | 744.00 | 24.15 | 39.83 | 24.21 |
| September | 95.17 | 25.40 | 720.00 | 24.38 | 95.17 | 24.48 |
| October | 93.33 | 24.86 | 682.83 | 24.42 | 83.83 | 24.47 |
| November | 146.83 | 24.49 | 468.17 | 24.69 | 51.83 | 24.74 |
| December | 386.33 | 23.74 | 287.83 | 24.12 | 59.33 | 24.19 |
| Annual Sum or Average | 2648.50 | 23.79 | 6428.33 | 24.13 | 963.50 | 24.19 |
| Minimum of Months | 39.83 | 23.24 | 205.67 | 23.62 | 39.83 | 23.69 |
| Maximum of Months | 566.17 | 25.40 | 744.00 | 24.69 | 138.67 | 24.74 |
Report: ComfortReportSimple55Monthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 36.33 | 23.70 | 47.67 | 23.87 | 0.00 | 23.87 |
| February | 28.67 | 23.63 | 77.17 | 23.90 | 0.00 | 23.90 |
| March | 44.67 | 23.68 | 75.67 | 23.88 | 0.17 | 23.88 |
| April | 4.17 | 24.00 | 113.17 | 24.00 | 1.83 | 24.00 |
| May | 4.33 | 24.00 | 154.00 | 24.00 | 4.33 | 24.00 |
| June | 4.50 | 24.00 | 154.00 | 24.00 | 4.50 | 24.00 |
| July | 3.67 | 24.00 | 140.00 | 24.00 | 3.67 | 24.00 |
| August | 3.33 | 24.00 | 161.00 | 24.00 | 3.33 | 24.00 |
| September | 0.83 | 24.00 | 140.00 | 24.00 | 0.83 | 24.00 |
| October | 1.17 | 24.00 | 140.00 | 24.00 | 1.17 | 24.00 |
| November | 1.00 | 24.00 | 113.67 | 24.00 | 0.50 | 24.00 |
| December | 20.67 | 23.65 | 70.67 | 23.92 | 0.00 | 23.92 |
| Annual Sum or Average | 153.33 | 23.72 | 1387.00 | 23.97 | 20.33 | 23.97 |
| Minimum of Months | 0.83 | 23.63 | 47.67 | 23.87 | 0.00 | 23.87 |
| Maximum of Months | 44.67 | 24.00 | 161.00 | 24.00 | 4.50 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 574.17 | 23.35 | 205.33 | 23.64 | 70.00 | 23.72 |
| February | 449.67 | 23.29 | 296.33 | 23.71 | 99.17 | 23.80 |
| March | 441.50 | 23.53 | 276.00 | 23.88 | 95.83 | 23.97 |
| April | 156.33 | 24.64 | 541.33 | 24.51 | 118.33 | 24.56 |
| May | 129.17 | 24.44 | 744.00 | 24.15 | 129.17 | 24.19 |
| June | 57.00 | 24.56 | 720.00 | 24.10 | 57.00 | 24.13 |
| July | 61.00 | 24.45 | 744.00 | 24.08 | 61.00 | 24.11 |
| August | 40.67 | 25.25 | 744.00 | 24.15 | 40.67 | 24.21 |
| September | 96.50 | 25.43 | 720.00 | 24.38 | 96.50 | 24.49 |
| October | 87.33 | 24.95 | 678.83 | 24.42 | 78.17 | 24.48 |
| November | 137.00 | 24.58 | 478.17 | 24.71 | 53.17 | 24.77 |
| December | 397.33 | 23.74 | 279.33 | 24.10 | 64.00 | 24.18 |
| Annual Sum or Average | 2627.67 | 23.83 | 6427.33 | 24.14 | 963.00 | 24.21 |
| Minimum of Months | 40.67 | 23.29 | 205.33 | 23.64 | 40.67 | 23.72 |
| Maximum of Months | 574.17 | 25.43 | 744.00 | 24.71 | 129.17 | 24.77 |
Report: ComfortReportSimple55Monthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.67 | 23.73 | 214.00 | 23.94 | 67.00 | 24.00 |
| February | 409.17 | 23.67 | 299.17 | 23.98 | 88.33 | 24.04 |
| March | 401.50 | 23.81 | 284.83 | 24.07 | 85.17 | 24.15 |
| April | 126.33 | 24.79 | 554.17 | 24.52 | 103.17 | 24.58 |
| May | 119.00 | 24.46 | 744.00 | 24.15 | 119.00 | 24.19 |
| June | 73.17 | 24.43 | 720.00 | 24.09 | 73.17 | 24.12 |
| July | 85.00 | 24.36 | 744.00 | 24.08 | 85.00 | 24.10 |
| August | 48.00 | 25.08 | 744.00 | 24.15 | 48.00 | 24.20 |
| September | 101.00 | 25.33 | 720.00 | 24.36 | 101.00 | 24.47 |
| October | 102.67 | 24.77 | 681.83 | 24.39 | 95.17 | 24.44 |
| November | 129.50 | 24.62 | 467.33 | 24.68 | 55.83 | 24.75 |
| December | 341.17 | 24.05 | 292.67 | 24.31 | 62.33 | 24.39 |
| Annual Sum or Average | 2470.17 | 24.09 | 6466.00 | 24.22 | 983.17 | 24.28 |
| Minimum of Months | 48.00 | 23.67 | 214.00 | 23.94 | 48.00 | 24.00 |
| Maximum of Months | 533.67 | 25.33 | 744.00 | 24.68 | 119.00 | 24.75 |
Report: ComfortReportSimple55Monthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 533.17 | 23.73 | 213.83 | 23.94 | 67.00 | 24.01 |
| February | 407.67 | 23.67 | 299.50 | 23.98 | 88.50 | 24.04 |
| March | 400.50 | 23.82 | 285.17 | 24.07 | 84.50 | 24.15 |
| April | 126.00 | 24.80 | 554.00 | 24.52 | 103.33 | 24.58 |
| May | 118.33 | 24.46 | 744.00 | 24.15 | 118.33 | 24.19 |
| June | 73.00 | 24.43 | 720.00 | 24.09 | 73.00 | 24.12 |
| July | 83.83 | 24.36 | 744.00 | 24.08 | 83.83 | 24.10 |
| August | 48.83 | 25.06 | 744.00 | 24.15 | 48.83 | 24.20 |
| September | 101.17 | 25.33 | 720.00 | 24.36 | 101.17 | 24.47 |
| October | 102.50 | 24.77 | 681.33 | 24.39 | 95.00 | 24.44 |
| November | 128.83 | 24.62 | 468.00 | 24.68 | 55.83 | 24.75 |
| December | 342.83 | 24.05 | 292.17 | 24.31 | 62.50 | 24.38 |
| Annual Sum or Average | 2466.67 | 24.09 | 6466.00 | 24.22 | 981.83 | 24.28 |
| Minimum of Months | 48.83 | 23.67 | 213.83 | 23.94 | 48.83 | 24.01 |
| Maximum of Months | 533.17 | 25.33 | 744.00 | 24.68 | 118.33 | 24.75 |
Report: ComfortReportSimple55Monthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 171.33 | 24.10 | 213.33 | 24.44 | 23.00 | 24.47 |
| February | 123.67 | 23.92 | 255.00 | 24.35 | 9.67 | 24.37 |
| March | 181.33 | 23.99 | 252.00 | 24.29 | 33.83 | 24.34 |
| April | 61.17 | 25.03 | 410.00 | 24.56 | 58.67 | 24.62 |
| May | 98.50 | 24.46 | 515.00 | 24.18 | 98.50 | 24.22 |
| June | 77.83 | 24.28 | 492.00 | 24.09 | 77.83 | 24.11 |
| July | 81.33 | 24.18 | 533.00 | 24.05 | 81.33 | 24.06 |
| August | 37.17 | 25.19 | 506.00 | 24.19 | 37.17 | 24.25 |
| September | 54.00 | 25.42 | 510.00 | 24.33 | 54.00 | 24.43 |
| October | 46.83 | 24.94 | 490.83 | 24.39 | 46.83 | 24.44 |
| November | 16.83 | 25.66 | 390.67 | 24.68 | 16.83 | 24.72 |
| December | 94.50 | 24.24 | 291.67 | 24.59 | 17.67 | 24.63 |
| Annual Sum or Average | 1044.50 | 24.35 | 4859.50 | 24.32 | 555.33 | 24.36 |
| Minimum of Months | 16.83 | 23.92 | 213.33 | 24.05 | 9.67 | 24.06 |
| Maximum of Months | 181.33 | 25.66 | 533.00 | 24.68 | 98.50 | 24.72 |
Report: ComfortReportSimple55Monthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 173.33 | 24.10 | 212.17 | 24.45 | 22.67 | 24.47 |
| February | 123.67 | 23.91 | 253.00 | 24.35 | 9.67 | 24.36 |
| March | 182.33 | 23.97 | 254.00 | 24.30 | 33.00 | 24.35 |
| April | 55.50 | 25.14 | 413.33 | 24.59 | 54.33 | 24.65 |
| May | 65.33 | 24.69 | 515.00 | 24.20 | 65.33 | 24.25 |
| June | 22.17 | 24.87 | 492.00 | 24.10 | 22.17 | 24.13 |
| July | 17.50 | 24.80 | 533.00 | 24.05 | 17.50 | 24.08 |
| August | 28.83 | 25.43 | 506.00 | 24.19 | 28.83 | 24.25 |
| September | 47.17 | 25.56 | 510.00 | 24.34 | 47.17 | 24.44 |
| October | 28.50 | 25.42 | 492.17 | 24.42 | 28.50 | 24.47 |
| November | 14.83 | 25.81 | 395.17 | 24.69 | 14.83 | 24.73 |
| December | 92.50 | 24.24 | 292.83 | 24.60 | 15.67 | 24.64 |
| Annual Sum or Average | 851.67 | 24.41 | 4868.67 | 24.34 | 359.67 | 24.39 |
| Minimum of Months | 14.83 | 23.91 | 212.17 | 24.05 | 9.67 | 24.08 |
| Maximum of Months | 182.33 | 25.81 | 533.00 | 24.69 | 65.33 | 24.73 |
Report: ComfortReportSimple55Monthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 232.00 | 23.79 | 203.83 | 24.24 | 22.83 | 24.27 |
| February | 135.00 | 23.67 | 256.17 | 24.35 | 10.50 | 24.37 |
| March | 156.67 | 23.84 | 279.17 | 24.38 | 27.17 | 24.44 |
| April | 44.67 | 25.30 | 430.67 | 24.70 | 44.67 | 24.76 |
| May | 68.17 | 24.63 | 515.00 | 24.19 | 68.17 | 24.23 |
| June | 25.00 | 24.85 | 492.00 | 24.10 | 25.00 | 24.13 |
| July | 63.17 | 24.20 | 533.00 | 24.05 | 63.17 | 24.06 |
| August | 60.33 | 24.72 | 506.00 | 24.17 | 60.33 | 24.22 |
| September | 77.00 | 24.99 | 510.00 | 24.30 | 77.00 | 24.38 |
| October | 72.50 | 24.60 | 474.17 | 24.35 | 62.83 | 24.38 |
| November | 53.67 | 24.46 | 344.17 | 24.65 | 19.17 | 24.68 |
| December | 160.17 | 23.87 | 262.33 | 24.41 | 20.67 | 24.45 |
| Annual Sum or Average | 1148.33 | 24.16 | 4806.50 | 24.31 | 501.50 | 24.35 |
| Minimum of Months | 25.00 | 23.67 | 203.83 | 24.05 | 10.50 | 24.06 |
| Maximum of Months | 232.00 | 25.30 | 533.00 | 24.70 | 77.00 | 24.76 |
Report: ComfortReportSimple55Monthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 522.33 | 23.34 | 218.00 | 23.71 | 58.67 | 23.79 |
| February | 311.67 | 23.51 | 322.50 | 24.10 | 52.67 | 24.18 |
| March | 304.17 | 23.81 | 370.67 | 24.29 | 60.00 | 24.36 |
| April | 82.00 | 25.20 | 597.50 | 24.74 | 76.50 | 24.79 |
| May | 85.50 | 24.61 | 744.00 | 24.16 | 85.50 | 24.20 |
| June | 35.67 | 24.89 | 720.00 | 24.10 | 35.67 | 24.13 |
| July | 75.50 | 24.36 | 744.00 | 24.08 | 75.50 | 24.10 |
| August | 79.00 | 24.63 | 744.00 | 24.14 | 79.00 | 24.18 |
| September | 143.83 | 24.87 | 720.00 | 24.32 | 143.83 | 24.39 |
| October | 155.83 | 24.44 | 660.33 | 24.32 | 131.83 | 24.35 |
| November | 177.00 | 24.33 | 447.83 | 24.58 | 57.67 | 24.63 |
| December | 399.67 | 23.60 | 288.33 | 24.01 | 64.50 | 24.09 |
| Annual Sum or Average | 2372.17 | 23.91 | 6577.17 | 24.20 | 921.33 | 24.26 |
| Minimum of Months | 35.67 | 23.34 | 218.00 | 23.71 | 35.67 | 23.79 |
| Maximum of Months | 522.33 | 25.20 | 744.00 | 24.74 | 143.83 | 24.79 |
Report: ComfortReportSimple55Monthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 237.17 | 23.80 | 205.00 | 24.24 | 24.00 | 24.27 |
| February | 133.33 | 23.67 | 256.50 | 24.34 | 10.67 | 24.36 |
| March | 158.17 | 23.85 | 273.00 | 24.39 | 25.67 | 24.45 |
| April | 45.33 | 25.43 | 428.50 | 24.72 | 45.33 | 24.78 |
| May | 66.67 | 24.68 | 515.00 | 24.19 | 66.67 | 24.24 |
| June | 24.17 | 24.95 | 492.00 | 24.10 | 24.17 | 24.14 |
| July | 64.33 | 24.22 | 533.00 | 24.05 | 64.33 | 24.07 |
| August | 72.83 | 24.62 | 506.00 | 24.17 | 72.83 | 24.22 |
| September | 82.83 | 24.94 | 510.00 | 24.30 | 82.83 | 24.38 |
| October | 71.67 | 24.63 | 472.17 | 24.35 | 62.50 | 24.39 |
| November | 53.50 | 24.51 | 344.67 | 24.66 | 20.00 | 24.69 |
| December | 167.83 | 23.87 | 262.50 | 24.40 | 22.00 | 24.44 |
| Annual Sum or Average | 1177.83 | 24.17 | 4798.33 | 24.31 | 521.00 | 24.35 |
| Minimum of Months | 24.17 | 23.67 | 205.00 | 24.05 | 10.67 | 24.07 |
| Maximum of Months | 237.17 | 25.43 | 533.00 | 24.72 | 82.83 | 24.78 |
Report: ComfortReportSimple55Monthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 527.67 | 23.40 | 213.83 | 23.73 | 61.50 | 23.82 |
| February | 310.83 | 23.57 | 319.83 | 24.11 | 59.00 | 24.20 |
| March | 289.33 | 23.88 | 374.83 | 24.34 | 58.33 | 24.43 |
| April | 79.00 | 25.41 | 613.00 | 24.80 | 76.67 | 24.86 |
| May | 81.67 | 24.68 | 744.00 | 24.16 | 81.67 | 24.21 |
| June | 32.50 | 25.02 | 720.00 | 24.10 | 32.50 | 24.14 |
| July | 74.33 | 24.39 | 744.00 | 24.08 | 74.33 | 24.10 |
| August | 89.67 | 24.59 | 744.00 | 24.14 | 89.67 | 24.18 |
| September | 145.00 | 24.89 | 720.00 | 24.32 | 145.00 | 24.40 |
| October | 145.17 | 24.50 | 654.67 | 24.33 | 123.17 | 24.36 |
| November | 174.33 | 24.39 | 456.50 | 24.59 | 60.67 | 24.65 |
| December | 416.17 | 23.61 | 285.17 | 24.00 | 69.33 | 24.08 |
| Annual Sum or Average | 2365.67 | 23.96 | 6589.83 | 24.22 | 931.83 | 24.28 |
| Minimum of Months | 32.50 | 23.40 | 213.83 | 23.73 | 32.50 | 23.82 |
| Maximum of Months | 527.67 | 25.41 | 744.00 | 24.80 | 145.00 | 24.86 |
Report: ComfortReportSimple55Monthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 478.83 | 23.85 | 225.17 | 24.09 | 60.17 | 24.16 |
| February | 288.50 | 23.94 | 329.33 | 24.30 | 59.00 | 24.37 |
| March | 287.17 | 24.14 | 360.50 | 24.40 | 62.67 | 24.47 |
| April | 83.00 | 25.26 | 591.17 | 24.68 | 83.00 | 24.75 |
| May | 88.00 | 24.61 | 744.00 | 24.15 | 88.00 | 24.20 |
| June | 50.67 | 24.62 | 720.00 | 24.09 | 50.67 | 24.12 |
| July | 113.00 | 24.27 | 744.00 | 24.07 | 113.00 | 24.10 |
| August | 123.17 | 24.43 | 744.00 | 24.13 | 123.17 | 24.16 |
| September | 163.50 | 24.77 | 720.00 | 24.30 | 163.50 | 24.37 |
| October | 169.33 | 24.40 | 653.50 | 24.30 | 147.17 | 24.32 |
| November | 159.83 | 24.46 | 452.00 | 24.58 | 62.17 | 24.64 |
| December | 348.67 | 24.01 | 294.67 | 24.27 | 67.00 | 24.35 |
| Annual Sum or Average | 2353.67 | 24.21 | 6578.33 | 24.27 | 1079.50 | 24.32 |
| Minimum of Months | 50.67 | 23.85 | 225.17 | 24.07 | 50.67 | 24.10 |
| Maximum of Months | 478.83 | 25.26 | 744.00 | 24.68 | 163.50 | 24.75 |
Report: ComfortReportSimple55Monthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 479.00 | 23.86 | 225.67 | 24.09 | 60.17 | 24.16 |
| February | 288.33 | 23.95 | 330.33 | 24.30 | 59.17 | 24.37 |
| March | 286.17 | 24.15 | 362.17 | 24.41 | 62.17 | 24.48 |
| April | 82.67 | 25.26 | 592.50 | 24.69 | 82.67 | 24.75 |
| May | 87.83 | 24.61 | 744.00 | 24.15 | 87.83 | 24.20 |
| June | 50.33 | 24.62 | 720.00 | 24.09 | 50.33 | 24.12 |
| July | 112.50 | 24.27 | 744.00 | 24.07 | 112.50 | 24.10 |
| August | 123.17 | 24.43 | 744.00 | 24.13 | 123.17 | 24.16 |
| September | 163.83 | 24.76 | 720.00 | 24.30 | 163.83 | 24.37 |
| October | 168.83 | 24.40 | 653.33 | 24.30 | 146.67 | 24.32 |
| November | 159.33 | 24.46 | 452.17 | 24.59 | 62.17 | 24.64 |
| December | 350.67 | 24.01 | 294.67 | 24.27 | 67.50 | 24.35 |
| Annual Sum or Average | 2352.67 | 24.21 | 6582.83 | 24.27 | 1078.17 | 24.32 |
| Minimum of Months | 50.33 | 23.86 | 225.67 | 24.07 | 50.33 | 24.10 |
| Maximum of Months | 479.00 | 25.26 | 744.00 | 24.69 | 163.83 | 24.75 |
Report: ComfortReportSimple55Monthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 165.33 | 24.10 | 212.17 | 24.48 | 23.33 | 24.51 |
| February | 118.83 | 23.99 | 268.83 | 24.49 | 9.33 | 24.50 |
| March | 124.50 | 24.19 | 279.67 | 24.51 | 27.50 | 24.56 |
| April | 48.33 | 25.32 | 434.17 | 24.68 | 48.33 | 24.74 |
| May | 69.83 | 24.63 | 515.00 | 24.18 | 69.83 | 24.23 |
| June | 42.50 | 24.50 | 492.00 | 24.09 | 42.50 | 24.12 |
| July | 100.83 | 24.14 | 533.00 | 24.05 | 100.83 | 24.06 |
| August | 91.33 | 24.49 | 506.00 | 24.16 | 91.33 | 24.20 |
| September | 82.83 | 24.94 | 510.00 | 24.30 | 82.83 | 24.37 |
| October | 70.67 | 24.61 | 477.83 | 24.34 | 64.50 | 24.38 |
| November | 35.33 | 24.76 | 360.00 | 24.69 | 19.33 | 24.72 |
| December | 113.50 | 24.17 | 273.00 | 24.59 | 21.00 | 24.63 |
| Annual Sum or Average | 1063.83 | 24.37 | 4861.67 | 24.34 | 600.67 | 24.38 |
| Minimum of Months | 35.33 | 23.99 | 212.17 | 24.05 | 9.33 | 24.06 |
| Maximum of Months | 165.33 | 25.32 | 533.00 | 24.69 | 100.83 | 24.74 |
Report: ComfortReportSimple55Monthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 165.83 | 24.10 | 212.17 | 24.48 | 23.33 | 24.51 |
| February | 119.00 | 23.99 | 269.00 | 24.49 | 9.33 | 24.50 |
| March | 124.33 | 24.19 | 279.00 | 24.51 | 27.50 | 24.56 |
| April | 48.33 | 25.32 | 434.17 | 24.68 | 48.33 | 24.74 |
| May | 69.33 | 24.63 | 515.00 | 24.18 | 69.33 | 24.23 |
| June | 42.17 | 24.50 | 492.00 | 24.09 | 42.17 | 24.12 |
| July | 100.67 | 24.14 | 533.00 | 24.05 | 100.67 | 24.06 |
| August | 91.33 | 24.49 | 506.00 | 24.16 | 91.33 | 24.20 |
| September | 83.00 | 24.94 | 510.00 | 24.30 | 83.00 | 24.37 |
| October | 70.83 | 24.61 | 477.67 | 24.34 | 64.67 | 24.38 |
| November | 35.33 | 24.76 | 359.67 | 24.69 | 19.33 | 24.72 |
| December | 113.67 | 24.17 | 272.67 | 24.59 | 21.00 | 24.62 |
| Annual Sum or Average | 1063.83 | 24.37 | 4860.33 | 24.34 | 600.00 | 24.38 |
| Minimum of Months | 35.33 | 23.99 | 212.17 | 24.05 | 9.33 | 24.06 |
| Maximum of Months | 165.83 | 25.32 | 533.00 | 24.69 | 100.67 | 24.74 |
Report: ComfortReportSimple55Monthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 349.33 | 22.47 | 199.83 | 23.09 | 61.67 | 23.06 |
| February | 234.83 | 22.66 | 246.67 | 23.46 | 64.17 | 23.36 |
| March | 249.17 | 22.90 | 259.67 | 23.68 | 65.50 | 23.67 |
| April | 110.00 | 24.56 | 383.33 | 24.67 | 64.50 | 24.74 |
| May | 120.33 | 24.37 | 515.00 | 24.17 | 120.33 | 24.20 |
| June | 98.50 | 24.23 | 492.00 | 24.08 | 98.50 | 24.11 |
| July | 154.83 | 24.09 | 533.00 | 24.05 | 154.83 | 24.06 |
| August | 155.67 | 24.28 | 505.67 | 24.15 | 155.67 | 24.17 |
| September | 163.17 | 24.53 | 510.00 | 24.29 | 163.17 | 24.33 |
| October | 151.67 | 24.19 | 453.83 | 24.27 | 114.33 | 24.30 |
| November | 177.83 | 23.53 | 283.83 | 24.25 | 44.50 | 24.29 |
| December | 294.67 | 22.72 | 241.83 | 23.53 | 55.00 | 23.54 |
| Annual Sum or Average | 2260.00 | 23.43 | 4624.67 | 23.99 | 1162.17 | 24.01 |
| Minimum of Months | 98.50 | 22.47 | 199.83 | 23.09 | 44.50 | 23.06 |
| Maximum of Months | 349.33 | 24.56 | 533.00 | 24.67 | 163.17 | 24.74 |
Report: ComfortReportSimple55Monthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 597.83 | 22.15 | 305.67 | 22.55 | 190.50 | 22.54 |
| February | 425.00 | 22.57 | 354.00 | 23.17 | 158.67 | 23.11 |
| March | 428.33 | 22.89 | 368.33 | 23.58 | 126.50 | 23.60 |
| April | 176.17 | 24.58 | 556.83 | 24.69 | 106.67 | 24.77 |
| May | 146.83 | 24.37 | 744.00 | 24.15 | 146.83 | 24.18 |
| June | 111.33 | 24.30 | 720.00 | 24.09 | 111.33 | 24.11 |
| July | 179.83 | 24.20 | 744.00 | 24.09 | 179.83 | 24.10 |
| August | 194.33 | 24.27 | 743.67 | 24.12 | 194.33 | 24.15 |
| September | 236.00 | 24.57 | 720.00 | 24.31 | 236.00 | 24.36 |
| October | 234.00 | 24.06 | 635.33 | 24.22 | 168.67 | 24.25 |
| November | 347.67 | 23.30 | 380.50 | 24.02 | 90.00 | 24.09 |
| December | 540.67 | 22.45 | 324.00 | 22.97 | 154.50 | 22.99 |
| Annual Sum or Average | 3618.00 | 23.22 | 6596.33 | 23.83 | 1863.83 | 23.85 |
| Minimum of Months | 111.33 | 22.15 | 305.67 | 22.55 | 90.00 | 22.54 |
| Maximum of Months | 597.83 | 24.58 | 744.00 | 24.69 | 236.00 | 24.77 |
Report: ComfortReportSimple55Monthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 354.17 | 22.49 | 202.83 | 23.10 | 65.17 | 23.08 |
| February | 238.83 | 22.67 | 245.33 | 23.43 | 65.50 | 23.33 |
| March | 246.33 | 22.85 | 256.00 | 23.66 | 63.00 | 23.64 |
| April | 110.00 | 24.53 | 383.50 | 24.66 | 63.83 | 24.72 |
| May | 121.17 | 24.39 | 515.00 | 24.18 | 121.17 | 24.21 |
| June | 106.33 | 24.24 | 492.00 | 24.09 | 106.33 | 24.11 |
| July | 155.17 | 24.09 | 533.00 | 24.05 | 155.17 | 24.05 |
| August | 166.50 | 24.28 | 505.67 | 24.15 | 166.50 | 24.17 |
| September | 168.33 | 24.50 | 510.00 | 24.28 | 168.33 | 24.32 |
| October | 153.33 | 24.17 | 454.33 | 24.26 | 115.00 | 24.29 |
| November | 178.67 | 23.55 | 284.00 | 24.26 | 47.83 | 24.30 |
| December | 302.83 | 22.74 | 240.33 | 23.51 | 61.00 | 23.54 |
| Annual Sum or Average | 2301.67 | 23.44 | 4622.00 | 23.98 | 1198.83 | 24.01 |
| Minimum of Months | 106.33 | 22.49 | 202.83 | 23.10 | 47.83 | 23.08 |
| Maximum of Months | 354.17 | 24.53 | 533.00 | 24.66 | 168.33 | 24.72 |
Report: ComfortReportSimple55Monthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 606.83 | 22.16 | 302.17 | 22.52 | 200.00 | 22.53 |
| February | 432.50 | 22.63 | 355.83 | 23.18 | 170.50 | 23.14 |
| March | 420.50 | 22.94 | 366.83 | 23.63 | 117.50 | 23.64 |
| April | 164.67 | 24.68 | 573.67 | 24.74 | 103.67 | 24.82 |
| May | 142.17 | 24.41 | 744.00 | 24.16 | 142.17 | 24.19 |
| June | 115.17 | 24.31 | 720.00 | 24.09 | 115.17 | 24.12 |
| July | 173.17 | 24.21 | 744.00 | 24.09 | 173.17 | 24.10 |
| August | 197.83 | 24.28 | 743.67 | 24.13 | 197.83 | 24.15 |
| September | 236.17 | 24.58 | 720.00 | 24.31 | 236.17 | 24.37 |
| October | 232.67 | 24.09 | 633.50 | 24.22 | 165.00 | 24.26 |
| November | 354.33 | 23.44 | 377.83 | 24.06 | 94.17 | 24.14 |
| December | 563.17 | 22.51 | 317.17 | 22.98 | 162.50 | 23.02 |
| Annual Sum or Average | 3639.17 | 23.25 | 6598.67 | 23.84 | 1877.83 | 23.86 |
| Minimum of Months | 115.17 | 22.16 | 302.17 | 22.52 | 94.17 | 22.53 |
| Maximum of Months | 606.83 | 24.68 | 744.00 | 24.74 | 236.17 | 24.82 |
Report: ComfortReportSimple55Monthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 591.33 | 22.24 | 252.17 | 22.68 | 131.33 | 22.73 |
| February | 405.00 | 22.69 | 343.67 | 23.29 | 132.17 | 23.26 |
| March | 395.17 | 23.00 | 341.17 | 23.66 | 93.67 | 23.70 |
| April | 153.33 | 24.71 | 568.50 | 24.67 | 94.83 | 24.75 |
| May | 130.67 | 24.43 | 744.00 | 24.15 | 130.67 | 24.19 |
| June | 121.00 | 24.28 | 720.00 | 24.09 | 121.00 | 24.11 |
| July | 189.33 | 24.17 | 744.00 | 24.08 | 189.33 | 24.09 |
| August | 193.17 | 24.28 | 744.00 | 24.13 | 193.17 | 24.15 |
| September | 228.83 | 24.59 | 720.00 | 24.31 | 228.83 | 24.36 |
| October | 227.00 | 24.17 | 635.67 | 24.23 | 166.67 | 24.26 |
| November | 327.83 | 23.62 | 379.17 | 24.15 | 89.00 | 24.22 |
| December | 529.17 | 22.65 | 290.50 | 23.14 | 122.33 | 23.20 |
| Annual Sum or Average | 3491.83 | 23.33 | 6482.83 | 23.89 | 1693.00 | 23.93 |
| Minimum of Months | 121.00 | 22.24 | 252.17 | 22.68 | 89.00 | 22.73 |
| Maximum of Months | 591.33 | 24.71 | 744.00 | 24.67 | 228.83 | 24.75 |
Report: ComfortReportSimple55Monthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 592.83 | 22.24 | 252.67 | 22.69 | 132.17 | 22.73 |
| February | 404.83 | 22.69 | 343.67 | 23.29 | 132.33 | 23.26 |
| March | 395.00 | 23.00 | 341.33 | 23.66 | 93.83 | 23.71 |
| April | 152.50 | 24.71 | 570.00 | 24.68 | 94.50 | 24.75 |
| May | 130.83 | 24.43 | 744.00 | 24.15 | 130.83 | 24.19 |
| June | 121.17 | 24.28 | 720.00 | 24.09 | 121.17 | 24.11 |
| July | 188.67 | 24.17 | 744.00 | 24.08 | 188.67 | 24.09 |
| August | 192.83 | 24.28 | 744.00 | 24.13 | 192.83 | 24.15 |
| September | 228.67 | 24.59 | 720.00 | 24.31 | 228.67 | 24.36 |
| October | 226.83 | 24.17 | 635.17 | 24.23 | 166.33 | 24.26 |
| November | 327.83 | 23.63 | 379.67 | 24.15 | 88.83 | 24.22 |
| December | 532.50 | 22.65 | 290.67 | 23.14 | 122.67 | 23.20 |
| Annual Sum or Average | 3494.50 | 23.33 | 6485.17 | 23.89 | 1692.83 | 23.93 |
| Minimum of Months | 121.17 | 22.24 | 252.67 | 22.69 | 88.83 | 22.73 |
| Maximum of Months | 592.83 | 24.71 | 744.00 | 24.68 | 228.67 | 24.75 |
Report: ComfortReportSimple55Monthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 323.33 | 22.82 | 192.83 | 23.45 | 36.83 | 23.46 |
| February | 205.33 | 22.92 | 242.67 | 23.74 | 39.67 | 23.68 |
| March | 221.17 | 23.08 | 253.17 | 23.86 | 43.00 | 23.88 |
| April | 87.17 | 24.67 | 398.33 | 24.65 | 52.50 | 24.71 |
| May | 109.83 | 24.42 | 515.00 | 24.17 | 109.83 | 24.21 |
| June | 107.67 | 24.22 | 492.00 | 24.09 | 107.67 | 24.10 |
| July | 169.50 | 24.08 | 533.00 | 24.04 | 169.50 | 24.05 |
| August | 154.17 | 24.30 | 506.00 | 24.15 | 154.17 | 24.18 |
| September | 151.00 | 24.54 | 510.00 | 24.28 | 151.00 | 24.33 |
| October | 133.00 | 24.29 | 458.17 | 24.30 | 106.00 | 24.32 |
| November | 129.33 | 23.85 | 298.00 | 24.45 | 34.33 | 24.49 |
| December | 254.00 | 23.03 | 246.33 | 23.82 | 37.83 | 23.85 |
| Annual Sum or Average | 2045.50 | 23.63 | 4645.50 | 24.09 | 1042.33 | 24.12 |
| Minimum of Months | 87.17 | 22.82 | 192.83 | 23.45 | 34.33 | 23.46 |
| Maximum of Months | 323.33 | 24.67 | 533.00 | 24.65 | 169.50 | 24.71 |
Report: ComfortReportSimple55Monthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 323.83 | 22.82 | 192.83 | 23.45 | 37.00 | 23.46 |
| February | 205.50 | 22.92 | 243.17 | 23.74 | 40.17 | 23.68 |
| March | 221.17 | 23.09 | 253.17 | 23.86 | 43.67 | 23.89 |
| April | 87.00 | 24.67 | 398.33 | 24.65 | 52.17 | 24.71 |
| May | 109.50 | 24.42 | 515.00 | 24.17 | 109.50 | 24.21 |
| June | 108.17 | 24.21 | 492.00 | 24.09 | 108.17 | 24.10 |
| July | 169.83 | 24.08 | 533.00 | 24.04 | 169.83 | 24.05 |
| August | 154.17 | 24.30 | 506.00 | 24.15 | 154.17 | 24.18 |
| September | 150.67 | 24.54 | 510.00 | 24.28 | 150.67 | 24.33 |
| October | 133.00 | 24.29 | 458.17 | 24.30 | 105.83 | 24.32 |
| November | 129.67 | 23.85 | 297.50 | 24.45 | 34.67 | 24.49 |
| December | 254.50 | 23.02 | 246.17 | 23.81 | 37.83 | 23.84 |
| Annual Sum or Average | 2047.00 | 23.63 | 4645.33 | 24.09 | 1043.67 | 24.12 |
| Minimum of Months | 87.00 | 22.82 | 192.83 | 23.45 | 34.67 | 23.46 |
| Maximum of Months | 323.83 | 24.67 | 533.00 | 24.65 | 169.83 | 24.71 |
Report: ComfortReportSimple55Monthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 23.65 | 744.00 | 23.65 | 744.00 | 23.65 |
| February | 672.00 | 24.36 | 672.00 | 24.36 | 672.00 | 24.36 |
| March | 744.00 | 24.66 | 744.00 | 24.66 | 744.00 | 24.66 |
| April | 720.00 | 25.88 | 720.00 | 25.88 | 720.00 | 25.88 |
| May | 744.00 | 26.23 | 744.00 | 26.23 | 744.00 | 26.23 |
| June | 720.00 | 26.30 | 720.00 | 26.30 | 720.00 | 26.30 |
| July | 744.00 | 26.33 | 744.00 | 26.33 | 744.00 | 26.33 |
| August | 744.00 | 26.30 | 744.00 | 26.30 | 744.00 | 26.30 |
| September | 720.00 | 26.23 | 720.00 | 26.23 | 720.00 | 26.23 |
| October | 744.00 | 26.03 | 744.00 | 26.03 | 744.00 | 26.03 |
| November | 720.00 | 25.26 | 720.00 | 25.26 | 720.00 | 25.26 |
| December | 744.00 | 24.18 | 744.00 | 24.18 | 744.00 | 24.18 |
| Annual Sum or Average | 8760.00 | 25.45 | 8760.00 | 25.45 | 8760.00 | 25.45 |
| Minimum of Months | 672.00 | 23.65 | 672.00 | 23.65 | 672.00 | 23.65 |
| Maximum of Months | 744.00 | 26.33 | 744.00 | 26.33 | 744.00 | 26.33 |
Report: ComfortReportSimple55Monthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 499.67 | 23.70 | 372.00 | 24.34 | 212.67 | 24.48 |
| February | 510.67 | 24.39 | 401.83 | 24.84 | 298.33 | 25.01 |
| March | 475.83 | 24.67 | 474.67 | 25.21 | 287.00 | 25.37 |
| April | 469.50 | 26.42 | 672.00 | 26.38 | 452.50 | 26.44 |
| May | 744.00 | 27.46 | 744.00 | 27.46 | 744.00 | 27.46 |
| June | 720.00 | 27.68 | 720.00 | 27.68 | 720.00 | 27.68 |
| July | 744.00 | 27.81 | 744.00 | 27.81 | 744.00 | 27.81 |
| August | 744.00 | 27.81 | 744.00 | 27.81 | 744.00 | 27.81 |
| September | 720.00 | 27.60 | 720.00 | 27.60 | 720.00 | 27.60 |
| October | 618.83 | 27.51 | 728.17 | 27.42 | 610.67 | 27.47 |
| November | 367.83 | 26.33 | 621.50 | 26.38 | 327.17 | 26.51 |
| December | 433.33 | 24.69 | 480.17 | 25.33 | 251.17 | 25.52 |
| Annual Sum or Average | 7047.67 | 26.60 | 7422.33 | 26.77 | 6111.50 | 26.90 |
| Minimum of Months | 367.83 | 23.70 | 372.00 | 24.34 | 212.67 | 24.48 |
| Maximum of Months | 744.00 | 27.81 | 744.00 | 27.81 | 744.00 | 27.81 |
Report: ComfortReportSimple55Monthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 25.26 | 744.00 | 25.26 | 744.00 | 25.26 |
| February | 672.00 | 25.56 | 672.00 | 25.56 | 672.00 | 25.56 |
| March | 744.00 | 25.67 | 744.00 | 25.67 | 744.00 | 25.67 |
| April | 720.00 | 26.14 | 720.00 | 26.14 | 720.00 | 26.14 |
| May | 744.00 | 26.04 | 744.00 | 26.04 | 744.00 | 26.04 |
| June | 720.00 | 26.06 | 720.00 | 26.06 | 720.00 | 26.06 |
| July | 744.00 | 26.06 | 744.00 | 26.06 | 744.00 | 26.06 |
| August | 744.00 | 26.06 | 744.00 | 26.06 | 744.00 | 26.06 |
| September | 720.00 | 26.08 | 720.00 | 26.08 | 720.00 | 26.08 |
| October | 744.00 | 26.08 | 744.00 | 26.08 | 744.00 | 26.08 |
| November | 720.00 | 25.98 | 720.00 | 25.98 | 720.00 | 25.98 |
| December | 744.00 | 25.52 | 744.00 | 25.52 | 744.00 | 25.52 |
| Annual Sum or Average | 8760.00 | 25.88 | 8760.00 | 25.88 | 8760.00 | 25.88 |
| Minimum of Months | 672.00 | 25.26 | 672.00 | 25.26 | 672.00 | 25.26 |
| Maximum of Months | 744.00 | 26.14 | 744.00 | 26.14 | 744.00 | 26.14 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 133.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 154.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 154.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 147.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 1750.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 133.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MSE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TSE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: SPLIT GSW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.104689E+10 | 0.263918E+09 | 386.40 | 0.918579E+09 | 0.128308E+09 | 0.00 | 1.00 | 01-JAN-10:52 | 0.00 | 01-JAN-06:13 | 6437.75 | 31-JAN-11:02 | 5924.68 | 15-JAN-18:02 | 2403.89 | 31-JAN-11:03 | 1360.65 | 17-JAN-13:12 | 0.00 |
| February | 0.963918E+09 | 0.240228E+09 | 307.02 | 0.801135E+09 | 0.162783E+09 | 0.00 | 1.00 | 01-FEB-13:22 | 0.00 | 01-FEB-06:13 | 6392.03 | 02-FEB-22:52 | 5885.73 | 08-FEB-13:52 | 2244.71 | 02-FEB-22:53 | 1385.87 | 01-FEB-14:42 | 0.00 |
| March | 0.955556E+09 | 0.240782E+09 | 322.41 | 0.779608E+09 | 0.175948E+09 | 0.00 | 1.00 | 01-MAR-19:42 | 0.00 | 01-MAR-07:00 | 6502.92 | 18-MAR-09:32 | 5873.72 | 24-MAR-12:32 | 2924.48 | 18-MAR-09:33 | 1387.41 | 27-MAR-11:02 | 0.00 |
| April | 0.159594E+10 | 0.408027E+09 | 428.43 | 0.128622E+10 | 0.309725E+09 | 0.00 | 1.00 | 01-APR-11:22 | 0.00 | 01-APR-05:15 | 6526.69 | 30-APR-11:02 | 5895.31 | 16-APR-20:42 | 2990.37 | 30-APR-11:03 | 1410.77 | 24-APR-11:53 | 0.00 |
| May | 0.346091E+10 | 0.909823E+09 | 688.91 | 0.262613E+10 | 0.834775E+09 | 0.00 | 1.00 | 02-MAY-07:52 | 0.00 | 02-MAY-05:15 | 6468.63 | 23-MAY-06:52 | 4918.47 | 27-MAY-18:52 | 2749.15 | 23-MAY-06:53 | 1385.68 | 16-MAY-06:52 | 0.00 |
| June | 0.369373E+10 | 0.979709E+09 | 690.75 | 0.281665E+10 | 0.877077E+09 | 0.00 | 1.00 | 01-JUN-07:32 | 0.00 | 01-JUN-05:15 | 6450.51 | 06-JUN-07:42 | 4728.42 | 01-JUN-14:02 | 2555.06 | 06-JUN-07:43 | 1452.04 | 01-JUN-14:02 | 0.00 |
| July | 0.435770E+10 | 0.114974E+10 | 724.86 | 0.323124E+10 | 0.112646E+10 | 0.00 | 1.00 | 11-JUL-21:22 | 0.00 | 11-JUL-19:33 | 6384.46 | 31-JUL-12:22 | 4906.76 | 12-JUL-17:32 | 2293.54 | 12-JUL-06:53 | 1385.68 | 12-JUL-06:52 | 0.00 |
| August | 0.466311E+10 | 0.122258E+10 | 704.94 | 0.358760E+10 | 0.107551E+10 | 0.00 | 1.00 | 01-AUG-06:52 | 0.00 | 01-AUG-05:15 | 6498.08 | 29-AUG-08:62 | 4885.39 | 16-AUG-16:12 | 2726.90 | 29-AUG-08:03 | 1394.66 | 27-AUG-07:42 | 0.00 |
| September | 0.432428E+10 | 0.111278E+10 | 634.94 | 0.332260E+10 | 0.100168E+10 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-05:43 | 6520.29 | 05-SEP-08:42 | 5146.70 | 06-SEP-20:02 | 2849.39 | 05-SEP-08:43 | 1382.27 | 01-SEP-07:02 | 0.00 |
| October | 0.405907E+10 | 0.104208E+10 | 600.61 | 0.328160E+10 | 0.777476E+09 | 0.00 | 1.00 | 01-OCT-09:52 | 0.00 | 01-OCT-05:15 | 6480.00 | 22-OCT-09:02 | 5957.60 | 17-OCT-16:42 | 2673.91 | 22-OCT-09:03 | 1390.56 | 12-OCT-09:02 | 0.00 |
| November | 0.224587E+10 | 0.565312E+09 | 476.95 | 0.194532E+10 | 0.300554E+09 | 0.00 | 1.00 | 01-NOV-07:32 | 0.00 | 01-NOV-05:13 | 6522.15 | 29-NOV-11:52 | 5931.29 | 26-NOV-13:02 | 2801.85 | 29-NOV-11:53 | 1396.98 | 29-NOV-12:52 | 0.00 |
| December | 0.163198E+10 | 0.411116E+09 | 464.79 | 0.141992E+10 | 0.212054E+09 | 0.00 | 1.00 | 01-DEC-11:32 | 0.00 | 01-DEC-09:45 | 6523.86 | 12-DEC-10:22 | 6013.81 | 17-DEC-13:42 | 2781.45 | 12-DEC-10:23 | 1375.98 | 14-DEC-11:43 | 0.00 |
| Annual Sum or Average | 0.329989E+11 | 0.854610E+10 | 6431.01 | 0.260166E+11 | 0.698235E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.955556E+09 | 0.240228E+09 | 307.02 | 0.779608E+09 | 0.128308E+09 | 0.00 | 1.00 | 0.00 | 6384.46 | 4728.42 | 2244.71 | 1360.65 | 0.00 | ||||||
| Maximum of Months | 0.466311E+10 | 0.122258E+10 | 724.86 | 0.358760E+10 | 0.112646E+10 | 0.00 | 1.00 | 0.00 | 6526.69 | 6013.81 | 2990.37 | 1452.04 | 0.00 |
Report: DXReportMonthly
For: SPLIT GNW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.329856E+09 | 82185949.74 | 132.30 | 0.252049E+09 | 77806219.70 | 0.00 | 1.00 | 01-JAN-12:42 | 0.00 | 01-JAN-06:03 | 6157.53 | 31-JAN-11:22 | 5313.32 | 02-JAN-22:12 | 2553.93 | 30-JAN-22:43 | 1306.28 | 19-JAN-11:23 | 0.00 |
| February | 0.403456E+09 | 0.100654E+09 | 147.65 | 0.304004E+09 | 99451799.95 | 0.00 | 1.00 | 01-FEB-14:12 | 0.00 | 01-FEB-06:13 | 6147.80 | 02-FEB-22:52 | 5014.49 | 26-FEB-19:02 | 2467.19 | 02-FEB-22:53 | 1322.12 | 21-FEB-13:52 | 0.00 |
| March | 0.590497E+09 | 0.148906E+09 | 242.56 | 0.448764E+09 | 0.141732E+09 | 0.00 | 1.00 | 01-MAR-19:42 | 0.00 | 01-MAR-06:40 | 6170.26 | 18-MAR-09:42 | 5523.62 | 24-MAR-14:02 | 2773.17 | 18-MAR-09:42 | 1314.14 | 26-MAR-10:02 | 0.00 |
| April | 0.134252E+10 | 0.343515E+09 | 393.11 | 0.105334E+10 | 0.289176E+09 | 0.00 | 1.00 | 01-APR-11:52 | 0.00 | 01-APR-05:15 | 6247.00 | 24-APR-10:42 | 5615.14 | 16-APR-20:42 | 2880.35 | 24-APR-10:43 | 1346.45 | 24-APR-11:53 | 0.00 |
| May | 0.344452E+10 | 0.903370E+09 | 689.38 | 0.260857E+10 | 0.835943E+09 | 0.00 | 1.00 | 02-MAY-07:52 | 0.00 | 02-MAY-05:15 | 6171.50 | 23-MAY-06:52 | 4724.86 | 27-MAY-18:52 | 2603.52 | 23-MAY-06:53 | 1322.58 | 16-MAY-06:52 | 0.00 |
| June | 0.377819E+10 | 0.999287E+09 | 691.72 | 0.289053E+10 | 0.887663E+09 | 0.00 | 1.00 | 01-JUN-07:32 | 0.00 | 01-JUN-05:15 | 6163.63 | 06-JUN-07:42 | 4492.43 | 01-JUN-14:02 | 2445.53 | 06-JUN-07:43 | 1386.50 | 01-JUN-14:02 | 0.00 |
| July | 0.438682E+10 | 0.115443E+10 | 724.93 | 0.325835E+10 | 0.112847E+10 | 0.00 | 1.00 | 11-JUL-21:22 | 0.00 | 11-JUL-19:33 | 6105.20 | 31-JUL-12:22 | 4662.13 | 12-JUL-16:32 | 2160.09 | 13-JUL-14:33 | 1322.58 | 12-JUL-06:52 | 0.00 |
| August | 0.452997E+10 | 0.118508E+10 | 704.92 | 0.346024E+10 | 0.106973E+10 | 0.00 | 1.00 | 01-AUG-06:52 | 0.00 | 01-AUG-05:15 | 6196.90 | 29-AUG-08:62 | 4603.00 | 16-AUG-16:12 | 2642.40 | 29-AUG-08:05 | 1331.13 | 27-AUG-07:42 | 0.00 |
| September | 0.398109E+10 | 0.102333E+10 | 632.69 | 0.300420E+10 | 0.976881E+09 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-05:43 | 6251.57 | 05-SEP-08:42 | 4978.61 | 02-SEP-17:12 | 2882.82 | 05-SEP-08:45 | 1319.42 | 01-SEP-07:02 | 0.00 |
| October | 0.333301E+10 | 0.858267E+09 | 582.08 | 0.260165E+10 | 0.731362E+09 | 0.00 | 1.00 | 01-OCT-10:52 | 0.00 | 01-OCT-05:15 | 6231.59 | 20-OCT-08:22 | 5625.77 | 17-OCT-16:32 | 2781.26 | 20-OCT-08:25 | 1328.80 | 10-OCT-09:12 | 0.00 |
| November | 0.134020E+10 | 0.339735E+09 | 410.89 | 0.108500E+10 | 0.255203E+09 | 0.00 | 1.00 | 01-NOV-07:42 | 0.00 | 01-NOV-05:13 | 6249.15 | 29-NOV-11:52 | 5660.68 | 19-NOV-16:32 | 2835.44 | 29-NOV-11:55 | 1333.36 | 29-NOV-12:53 | 0.00 |
| December | 0.790718E+09 | 0.198735E+09 | 263.15 | 0.621990E+09 | 0.168728E+09 | 0.00 | 1.00 | 01-DEC-14:42 | 0.00 | 01-DEC-09:45 | 6276.32 | 12-DEC-11:12 | 5641.19 | 01-DEC-17:12 | 2918.56 | 12-DEC-11:15 | 1312.66 | 09-DEC-10:42 | 0.00 |
| Annual Sum or Average | 0.282508E+11 | 0.733750E+10 | 5615.38 | 0.215887E+11 | 0.666214E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.329856E+09 | 82185949.74 | 132.30 | 0.252049E+09 | 77806219.70 | 0.00 | 1.00 | 0.00 | 6105.20 | 4492.43 | 2160.09 | 1306.28 | 0.00 | ||||||
| Maximum of Months | 0.452997E+10 | 0.118508E+10 | 724.93 | 0.346024E+10 | 0.112847E+10 | 0.00 | 1.00 | 0.00 | 6276.32 | 5660.68 | 2918.56 | 1386.50 | 0.00 |
Report: DXReportMonthly
For: SPLIT OFFICE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.920707E+09 | 0.233158E+09 | 176.93 | 0.801525E+09 | 0.119182E+09 | 0.00 | 1.00 | 03-JAN-07:01 | 0.00 | 01-JAN-00:10 | 7345.99 | 31-JAN-07:01 | 6306.77 | 03-JAN-07:01 | 2802.97 | 31-JAN-07:03 | 1543.59 | 18-JAN-07:01 | 0.00 |
| February | 0.103064E+10 | 0.258413E+09 | 171.43 | 0.860891E+09 | 0.169750E+09 | 0.00 | 1.00 | 01-FEB-07:01 | 0.00 | 01-FEB-00:10 | 7358.23 | 03-FEB-07:01 | 5247.81 | 24-FEB-07:01 | 2833.77 | 03-FEB-07:03 | 1543.60 | 27-FEB-07:02 | 0.00 |
| March | 0.112113E+10 | 0.282952E+09 | 204.12 | 0.935672E+09 | 0.185462E+09 | 0.00 | 1.00 | 01-MAR-07:01 | 0.00 | 01-MAR-00:10 | 7498.56 | 07-MAR-07:01 | 5787.58 | 01-MAR-07:01 | 3268.09 | 07-MAR-07:04 | 1543.61 | 06-MAR-07:03 | 0.00 |
| April | 0.149411E+10 | 0.379137E+09 | 204.03 | 0.123413E+10 | 0.259979E+09 | 0.00 | 1.00 | 04-APR-06:01 | 0.00 | 01-APR-00:10 | 7608.20 | 28-APR-06:01 | 6006.12 | 18-APR-06:01 | 3530.63 | 28-APR-06:05 | 1543.60 | 25-APR-06:01 | 0.00 |
| May | 0.299376E+10 | 0.759932E+09 | 259.11 | 0.227208E+10 | 0.721674E+09 | 0.00 | 1.00 | 01-MAY-06:01 | 0.00 | 01-MAY-00:10 | 7742.31 | 23-MAY-06:01 | 5143.61 | 12-MAY-06:01 | 4296.69 | 24-MAY-06:06 | 1598.87 | 22-MAY-06:08 | 0.00 |
| June | 0.323637E+10 | 0.823264E+09 | 270.63 | 0.242771E+10 | 0.808658E+09 | 0.00 | 1.00 | 01-JUN-06:01 | 0.00 | 01-JUN-00:10 | 7742.13 | 05-JUN-06:01 | 5264.66 | 07-JUN-06:01 | 4274.23 | 29-JUN-06:07 | 1627.51 | 28-JUN-06:23 | 0.00 |
| July | 0.346289E+10 | 0.870458E+09 | 323.32 | 0.250699E+10 | 0.955901E+09 | 0.00 | 1.00 | 03-JUL-06:01 | 0.00 | 01-JUL-00:10 | 7741.69 | 12-JUL-06:01 | 4385.88 | 17-JUL-06:01 | 4217.92 | 13-JUL-06:06 | 1628.88 | 19-JUL-06:23 | 0.00 |
| August | 0.402090E+10 | 0.100476E+10 | 344.63 | 0.297397E+10 | 0.104693E+10 | 0.00 | 1.00 | 01-AUG-06:01 | 0.00 | 01-AUG-00:10 | 7742.45 | 29-AUG-06:01 | 4736.69 | 04-AUG-06:01 | 4343.22 | 02-AUG-06:09 | 1602.33 | 22-AUG-06:35 | 0.00 |
| September | 0.347020E+10 | 0.848774E+09 | 339.23 | 0.255244E+10 | 0.917755E+09 | 0.00 | 1.00 | 01-SEP-06:01 | 0.00 | 01-SEP-00:10 | 7742.45 | 01-SEP-06:02 | 4979.41 | 22-SEP-06:01 | 3994.76 | 27-SEP-06:08 | 1606.40 | 12-SEP-06:10 | 0.00 |
| October | 0.330050E+10 | 0.818127E+09 | 312.11 | 0.263227E+10 | 0.668232E+09 | 0.00 | 1.00 | 02-OCT-06:01 | 0.00 | 01-OCT-00:10 | 7742.45 | 23-OCT-06:01 | 6784.09 | 17-OCT-06:01 | 4659.71 | 25-OCT-06:08 | 1606.40 | 06-OCT-06:25 | 0.00 |
| November | 0.198978E+10 | 0.494516E+09 | 208.99 | 0.170050E+10 | 0.289276E+09 | 0.00 | 1.00 | 01-NOV-06:01 | 0.00 | 01-NOV-00:10 | 7721.26 | 02-NOV-06:01 | 6709.52 | 14-NOV-07:01 | 3820.20 | 02-NOV-06:06 | 1543.60 | 06-NOV-07:03 | 0.00 |
| December | 0.128187E+10 | 0.321270E+09 | 195.63 | 0.109527E+10 | 0.186596E+09 | 0.00 | 1.00 | 01-DEC-07:01 | 0.00 | 01-DEC-00:10 | 7556.68 | 15-DEC-07:01 | 6539.19 | 01-DEC-07:01 | 3372.61 | 15-DEC-07:05 | 1542.59 | 13-DEC-07:13 | 0.00 |
| Annual Sum or Average | 0.283228E+11 | 0.709476E+10 | 3010.16 | 0.219934E+11 | 0.632940E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.920707E+09 | 0.233158E+09 | 171.43 | 0.801525E+09 | 0.119182E+09 | 0.00 | 1.00 | 0.00 | 7345.99 | 4385.88 | 2802.97 | 1542.59 | 0.00 | ||||||
| Maximum of Months | 0.402090E+10 | 0.100476E+10 | 344.63 | 0.297397E+10 | 0.104693E+10 | 0.00 | 1.00 | 0.00 | 7742.45 | 6784.09 | 4659.71 | 1628.88 | 0.00 |
Report: DXReportMonthly
For: SPLIT GNE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.309817E+09 | 77042370.74 | 124.59 | 0.234633E+09 | 75184258.60 | 0.00 | 1.00 | 01-JAN-12:42 | 0.00 | 01-JAN-06:03 | 5799.10 | 31-JAN-11:22 | 4985.81 | 02-JAN-22:12 | 2414.39 | 30-JAN-22:43 | 1230.28 | 19-JAN-11:25 | 0.00 |
| February | 0.366750E+09 | 91358966.35 | 147.29 | 0.272907E+09 | 93843011.06 | 0.00 | 1.00 | 01-FEB-14:12 | 0.00 | 01-FEB-06:13 | 5789.38 | 02-FEB-22:52 | 4503.72 | 27-FEB-18:42 | 2342.01 | 02-FEB-22:53 | 1244.85 | 21-FEB-13:52 | 0.00 |
| March | 0.606168E+09 | 0.152458E+09 | 240.57 | 0.460848E+09 | 0.145320E+09 | 0.00 | 1.00 | 01-MAR-19:42 | 0.00 | 01-MAR-06:40 | 5812.69 | 18-MAR-09:42 | 5226.30 | 24-MAR-14:02 | 2624.09 | 18-MAR-09:43 | 1237.79 | 26-MAR-10:02 | 0.00 |
| April | 0.133156E+10 | 0.339840E+09 | 395.00 | 0.104170E+10 | 0.289865E+09 | 0.00 | 1.00 | 01-APR-11:52 | 0.00 | 01-APR-05:15 | 5878.01 | 24-APR-10:42 | 5283.97 | 03-APR-12:22 | 2646.68 | 24-APR-10:43 | 1267.84 | 24-APR-11:55 | 0.00 |
| May | 0.352920E+10 | 0.922412E+09 | 691.60 | 0.268245E+10 | 0.846754E+09 | 0.00 | 1.00 | 02-MAY-07:52 | 0.00 | 02-MAY-05:15 | 5811.82 | 23-MAY-06:52 | 4495.23 | 13-MAY-12:52 | 2445.35 | 23-MAY-06:53 | 1245.31 | 16-MAY-06:52 | 0.00 |
| June | 0.383316E+10 | 0.101060E+10 | 693.53 | 0.293914E+10 | 0.894015E+09 | 0.00 | 1.00 | 01-JUN-07:32 | 0.00 | 01-JUN-05:15 | 5808.95 | 06-JUN-07:42 | 4303.10 | 01-JUN-14:02 | 2373.19 | 06-JUN-07:45 | 1303.78 | 01-JUN-14:02 | 0.00 |
| July | 0.447640E+10 | 0.117422E+10 | 725.00 | 0.334018E+10 | 0.113622E+10 | 0.00 | 1.00 | 11-JUL-21:22 | 0.00 | 11-JUL-19:33 | 5745.22 | 12-JUL-21:52 | 4308.46 | 12-JUL-15:42 | 2021.92 | 13-JUL-14:33 | 1245.31 | 12-JUL-06:52 | 0.00 |
| August | 0.454947E+10 | 0.118631E+10 | 705.00 | 0.347732E+10 | 0.107215E+10 | 0.00 | 1.00 | 01-AUG-06:52 | 0.00 | 01-AUG-05:15 | 5826.95 | 29-AUG-08:62 | 4322.96 | 16-AUG-16:12 | 2443.02 | 29-AUG-08:05 | 1253.37 | 27-AUG-07:42 | 0.00 |
| September | 0.398108E+10 | 0.102006E+10 | 632.38 | 0.300311E+10 | 0.977977E+09 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-05:43 | 5882.82 | 05-SEP-08:42 | 4598.10 | 02-SEP-17:12 | 2696.07 | 05-SEP-08:45 | 1242.36 | 01-SEP-07:02 | 0.00 |
| October | 0.331314E+10 | 0.850492E+09 | 581.08 | 0.258133E+10 | 0.731813E+09 | 0.00 | 1.00 | 01-OCT-10:52 | 0.00 | 01-OCT-05:15 | 5873.44 | 20-OCT-08:22 | 5323.37 | 17-OCT-18:12 | 2638.56 | 20-OCT-08:25 | 1251.01 | 10-OCT-09:12 | 0.00 |
| November | 0.133204E+10 | 0.337117E+09 | 410.70 | 0.107758E+10 | 0.254459E+09 | 0.00 | 1.00 | 01-NOV-07:42 | 0.00 | 01-NOV-05:13 | 5883.14 | 29-NOV-11:52 | 5306.82 | 18-NOV-17:52 | 2661.77 | 29-NOV-11:55 | 1255.45 | 29-NOV-12:53 | 0.00 |
| December | 0.743777E+09 | 0.186541E+09 | 256.46 | 0.578732E+09 | 0.165045E+09 | 0.00 | 1.00 | 01-DEC-14:42 | 0.00 | 01-DEC-09:45 | 5909.82 | 12-DEC-11:12 | 5313.67 | 01-DEC-17:12 | 2741.64 | 12-DEC-11:15 | 1236.18 | 09-DEC-10:42 | 0.00 |
| Annual Sum or Average | 0.283726E+11 | 0.734845E+10 | 5603.20 | 0.216899E+11 | 0.668265E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.309817E+09 | 77042370.74 | 124.59 | 0.234633E+09 | 75184258.60 | 0.00 | 1.00 | 0.00 | 5745.22 | 4303.10 | 2021.92 | 1230.28 | 0.00 | ||||||
| Maximum of Months | 0.454947E+10 | 0.118631E+10 | 725.00 | 0.347732E+10 | 0.113622E+10 | 0.00 | 1.00 | 0.00 | 5909.82 | 5323.37 | 2741.64 | 1303.78 | 0.00 |
Report: DXReportMonthly
For: SPLIT GN1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.354929E+09 | 88621904.58 | 201.94 | 0.275754E+09 | 79175316.86 | 0.00 | 1.00 | 01-JAN-12:42 | 0.00 | 01-JAN-06:13 | 5185.46 | 30-JAN-22:42 | 4464.48 | 02-JAN-22:12 | 2136.44 | 30-JAN-22:43 | 1099.46 | 19-JAN-11:23 | 0.00 |
| February | 0.423300E+09 | 0.105562E+09 | 200.25 | 0.319695E+09 | 0.103605E+09 | 0.00 | 1.00 | 01-FEB-14:12 | 0.00 | 01-FEB-06:13 | 5176.95 | 02-FEB-22:52 | 4002.82 | 26-FEB-19:02 | 2050.44 | 02-FEB-22:53 | 1112.74 | 21-FEB-13:52 | 0.00 |
| March | 0.648416E+09 | 0.163371E+09 | 301.00 | 0.499819E+09 | 0.148597E+09 | 0.00 | 1.00 | 01-MAR-19:42 | 0.00 | 01-MAR-07:00 | 5191.85 | 18-MAR-09:42 | 4668.61 | 04-MAR-22:52 | 2319.71 | 18-MAR-09:43 | 1106.09 | 26-MAR-10:02 | 0.00 |
| April | 0.130578E+10 | 0.332337E+09 | 415.40 | 0.101889E+10 | 0.286893E+09 | 0.00 | 1.00 | 01-APR-11:52 | 0.00 | 01-APR-05:15 | 5256.73 | 24-APR-10:42 | 4711.20 | 16-APR-20:42 | 2448.61 | 24-APR-10:45 | 1133.35 | 24-APR-11:55 | 0.00 |
| May | 0.313096E+10 | 0.815881E+09 | 689.27 | 0.233918E+10 | 0.791777E+09 | 0.00 | 1.00 | 02-MAY-07:52 | 0.00 | 02-MAY-05:15 | 5180.69 | 23-MAY-06:52 | 3908.19 | 31-MAY-21:52 | 2103.68 | 23-MAY-06:53 | 1113.18 | 16-MAY-06:52 | 0.00 |
| June | 0.336322E+10 | 0.884176E+09 | 690.78 | 0.252271E+10 | 0.840510E+09 | 0.00 | 1.00 | 01-JUN-07:32 | 0.00 | 01-JUN-05:15 | 5184.18 | 06-JUN-07:42 | 3766.39 | 01-JUN-14:02 | 2110.67 | 06-JUN-07:45 | 1167.06 | 01-JUN-14:02 | 0.00 |
| July | 0.387957E+10 | 0.101499E+10 | 724.74 | 0.281939E+10 | 0.106017E+10 | 0.00 | 1.00 | 11-JUL-21:22 | 0.00 | 11-JUL-19:33 | 5153.81 | 13-JUL-14:32 | 3706.70 | 12-JUL-15:42 | 1942.69 | 13-JUL-14:35 | 1113.18 | 12-JUL-06:52 | 0.00 |
| August | 0.390210E+10 | 0.101584E+10 | 703.45 | 0.291052E+10 | 0.991579E+09 | 0.00 | 1.00 | 01-AUG-06:52 | 0.00 | 01-AUG-05:15 | 5214.63 | 29-AUG-08:62 | 3793.30 | 20-AUG-07:42 | 2211.02 | 29-AUG-08:05 | 1120.40 | 27-AUG-07:42 | 0.00 |
| September | 0.346555E+10 | 0.885646E+09 | 630.41 | 0.255870E+10 | 0.906857E+09 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-05:43 | 5266.28 | 05-SEP-08:42 | 4035.11 | 06-SEP-20:02 | 2441.83 | 05-SEP-08:55 | 1112.82 | 05-SEP-08:55 | 0.00 |
| October | 0.289836E+10 | 0.742849E+09 | 583.52 | 0.222287E+10 | 0.675488E+09 | 0.00 | 1.00 | 01-OCT-10:52 | 0.00 | 01-OCT-05:15 | 5247.81 | 20-OCT-08:22 | 4750.25 | 17-OCT-18:12 | 2356.98 | 20-OCT-08:35 | 1118.42 | 10-OCT-09:12 | 0.00 |
| November | 0.130356E+10 | 0.329507E+09 | 423.82 | 0.105702E+10 | 0.246543E+09 | 0.00 | 1.00 | 01-NOV-07:42 | 0.00 | 01-NOV-05:13 | 5252.47 | 29-NOV-11:52 | 4735.21 | 30-NOV-15:21 | 2343.31 | 29-NOV-11:55 | 1122.26 | 29-NOV-12:53 | 0.00 |
| December | 0.816790E+09 | 0.205256E+09 | 360.72 | 0.650955E+09 | 0.165835E+09 | 0.00 | 1.00 | 01-DEC-14:42 | 0.00 | 01-DEC-09:45 | 5270.20 | 12-DEC-11:12 | 4738.21 | 01-DEC-17:12 | 2394.14 | 12-DEC-11:15 | 1111.13 | 13-DEC-11:35 | 0.00 |
| Annual Sum or Average | 0.254925E+11 | 0.658404E+10 | 5925.30 | 0.191955E+11 | 0.629703E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.354929E+09 | 88621904.58 | 200.25 | 0.275754E+09 | 79175316.86 | 0.00 | 1.00 | 0.00 | 5153.81 | 3706.70 | 1942.69 | 1099.46 | 0.00 | ||||||
| Maximum of Months | 0.390210E+10 | 0.101584E+10 | 724.74 | 0.291052E+10 | 0.106017E+10 | 0.00 | 1.00 | 0.00 | 5270.20 | 4750.25 | 2448.61 | 1167.06 | 0.00 |
Report: DXReportMonthly
For: SPLIT GN2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.354109E+09 | 88419179.55 | 202.81 | 0.275080E+09 | 79029113.90 | 0.00 | 1.00 | 01-JAN-12:42 | 0.00 | 01-JAN-06:13 | 5178.69 | 30-JAN-22:42 | 4457.49 | 02-JAN-22:12 | 2133.47 | 30-JAN-22:43 | 1098.00 | 19-JAN-11:23 | 0.00 |
| February | 0.422343E+09 | 0.105333E+09 | 201.60 | 0.318917E+09 | 0.103426E+09 | 0.00 | 1.00 | 01-FEB-14:12 | 0.00 | 01-FEB-06:13 | 5169.96 | 02-FEB-22:52 | 3993.98 | 26-FEB-19:02 | 2049.33 | 02-FEB-22:53 | 1111.27 | 21-FEB-13:52 | 0.00 |
| March | 0.650444E+09 | 0.163867E+09 | 301.26 | 0.501515E+09 | 0.148929E+09 | 0.00 | 1.00 | 01-MAR-19:42 | 0.00 | 01-MAR-07:00 | 5185.04 | 18-MAR-09:42 | 4660.26 | 04-MAR-22:52 | 2315.84 | 18-MAR-09:43 | 1104.64 | 26-MAR-10:02 | 0.00 |
| April | 0.130762E+10 | 0.332788E+09 | 415.59 | 0.102048E+10 | 0.287136E+09 | 0.00 | 1.00 | 01-APR-11:52 | 0.00 | 01-APR-05:15 | 5249.93 | 24-APR-10:42 | 4704.15 | 16-APR-20:42 | 2444.86 | 24-APR-10:45 | 1131.85 | 24-APR-11:55 | 0.00 |
| May | 0.313520E+10 | 0.816932E+09 | 689.27 | 0.234287E+10 | 0.792329E+09 | 0.00 | 1.00 | 02-MAY-07:52 | 0.00 | 02-MAY-05:15 | 5173.84 | 23-MAY-06:52 | 3902.93 | 31-MAY-21:52 | 2100.77 | 23-MAY-06:53 | 1111.72 | 16-MAY-06:52 | 0.00 |
| June | 0.336610E+10 | 0.884879E+09 | 690.72 | 0.252516E+10 | 0.840947E+09 | 0.00 | 1.00 | 01-JUN-07:32 | 0.00 | 01-JUN-05:15 | 5177.43 | 06-JUN-07:42 | 3764.70 | 01-JUN-14:02 | 2108.50 | 06-JUN-07:45 | 1165.49 | 01-JUN-14:02 | 0.00 |
| July | 0.388370E+10 | 0.101601E+10 | 724.74 | 0.282304E+10 | 0.106066E+10 | 0.00 | 1.00 | 11-JUL-21:22 | 0.00 | 11-JUL-19:33 | 5146.95 | 13-JUL-14:32 | 3703.16 | 12-JUL-15:42 | 1940.04 | 13-JUL-14:35 | 1111.71 | 12-JUL-06:52 | 0.00 |
| August | 0.390335E+10 | 0.101611E+10 | 703.53 | 0.291143E+10 | 0.991915E+09 | 0.00 | 1.00 | 01-AUG-06:52 | 0.00 | 01-AUG-05:15 | 5207.54 | 29-AUG-08:62 | 3788.43 | 20-AUG-07:42 | 2207.33 | 29-AUG-08:05 | 1118.93 | 27-AUG-07:42 | 0.00 |
| September | 0.346579E+10 | 0.885661E+09 | 630.41 | 0.255882E+10 | 0.906969E+09 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-05:43 | 5259.27 | 05-SEP-08:42 | 4028.31 | 06-SEP-20:02 | 2438.51 | 05-SEP-08:55 | 1111.36 | 05-SEP-08:55 | 0.00 |
| October | 0.289797E+10 | 0.742716E+09 | 583.47 | 0.222238E+10 | 0.675587E+09 | 0.00 | 1.00 | 01-OCT-10:52 | 0.00 | 01-OCT-05:15 | 5241.05 | 20-OCT-08:22 | 4743.37 | 17-OCT-18:12 | 2357.30 | 20-OCT-08:35 | 1116.95 | 10-OCT-09:12 | 0.00 |
| November | 0.130390E+10 | 0.329582E+09 | 424.03 | 0.105728E+10 | 0.246626E+09 | 0.00 | 1.00 | 01-NOV-07:42 | 0.00 | 01-NOV-05:13 | 5245.49 | 29-NOV-11:52 | 4728.95 | 30-NOV-15:21 | 2340.12 | 29-NOV-11:55 | 1120.78 | 29-NOV-12:53 | 0.00 |
| December | 0.812909E+09 | 0.204248E+09 | 358.33 | 0.647219E+09 | 0.165691E+09 | 0.00 | 1.00 | 01-DEC-14:42 | 0.00 | 01-DEC-09:45 | 5263.30 | 12-DEC-11:12 | 4729.98 | 01-DEC-17:12 | 2398.68 | 13-DEC-11:25 | 1109.61 | 13-DEC-11:35 | 0.00 |
| Annual Sum or Average | 0.255034E+11 | 0.658654E+10 | 5925.76 | 0.192042E+11 | 0.629924E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.354109E+09 | 88419179.55 | 201.60 | 0.275080E+09 | 79029113.90 | 0.00 | 1.00 | 0.00 | 5146.95 | 3703.16 | 1940.04 | 1098.00 | 0.00 | ||||||
| Maximum of Months | 0.390335E+10 | 0.101611E+10 | 724.74 | 0.291143E+10 | 0.106066E+10 | 0.00 | 1.00 | 0.00 | 5263.30 | 4743.37 | 2444.86 | 1165.49 | 0.00 |
Report: DXReportMonthly
For: SPLIT GS1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.128007E+10 | 0.324244E+09 | 523.62 | 0.114724E+10 | 0.132838E+09 | 0.00 | 1.00 | 01-JAN-10:52 | 0.00 | 01-JAN-06:13 | 5554.95 | 31-JAN-11:02 | 5125.52 | 15-JAN-18:02 | 2086.52 | 31-JAN-11:05 | 1176.59 | 17-JAN-13:12 | 0.00 |
| February | 0.112540E+10 | 0.281585E+09 | 391.67 | 0.954331E+09 | 0.171069E+09 | 0.00 | 1.00 | 01-FEB-13:22 | 0.00 | 01-FEB-06:13 | 5512.68 | 02-FEB-22:52 | 5099.91 | 08-FEB-12:42 | 1850.00 | 02-FEB-22:53 | 1198.54 | 01-FEB-14:42 | 0.00 |
| March | 0.107669E+10 | 0.271312E+09 | 384.55 | 0.893254E+09 | 0.183435E+09 | 0.00 | 1.00 | 01-MAR-07:53 | 0.00 | 01-MAR-07:00 | 5626.40 | 18-MAR-09:32 | 5095.44 | 24-MAR-12:32 | 2484.83 | 18-MAR-09:33 | 1199.74 | 27-MAR-11:02 | 0.00 |
| April | 0.157586E+10 | 0.401059E+09 | 426.15 | 0.126872E+10 | 0.307134E+09 | 0.00 | 1.00 | 01-APR-11:22 | 0.00 | 01-APR-05:15 | 5647.31 | 30-APR-11:02 | 5094.54 | 16-APR-20:42 | 2553.58 | 30-APR-11:03 | 1219.98 | 24-APR-11:53 | 0.00 |
| May | 0.315791E+10 | 0.825812E+09 | 688.82 | 0.236840E+10 | 0.789515E+09 | 0.00 | 1.00 | 02-MAY-07:52 | 0.00 | 02-MAY-05:15 | 5579.35 | 23-MAY-06:52 | 4193.75 | 31-MAY-21:52 | 2275.55 | 23-MAY-06:53 | 1198.29 | 16-MAY-06:52 | 0.00 |
| June | 0.328625E+10 | 0.867357E+09 | 690.00 | 0.245871E+10 | 0.827537E+09 | 0.00 | 1.00 | 01-JUN-07:32 | 0.00 | 01-JUN-05:15 | 5576.39 | 06-JUN-07:42 | 4076.36 | 01-JUN-14:02 | 2204.07 | 06-JUN-07:43 | 1255.67 | 01-JUN-14:02 | 0.00 |
| July | 0.386069E+10 | 0.101390E+10 | 724.47 | 0.280452E+10 | 0.105617E+10 | 0.00 | 1.00 | 11-JUL-21:22 | 0.00 | 11-JUL-19:33 | 5542.06 | 12-JUL-21:52 | 4091.96 | 12-JUL-15:32 | 2038.57 | 13-JUL-14:35 | 1198.29 | 12-JUL-06:52 | 0.00 |
| August | 0.404819E+10 | 0.105755E+10 | 703.50 | 0.305131E+10 | 0.996887E+09 | 0.00 | 1.00 | 01-AUG-06:52 | 0.00 | 01-AUG-05:15 | 5617.75 | 29-AUG-08:62 | 4143.31 | 16-AUG-16:12 | 2398.72 | 29-AUG-08:05 | 1206.07 | 27-AUG-07:42 | 0.00 |
| September | 0.382661E+10 | 0.980452E+09 | 633.74 | 0.289345E+10 | 0.933167E+09 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-05:43 | 5632.74 | 05-SEP-08:42 | 4382.55 | 06-SEP-20:02 | 2477.75 | 05-SEP-08:45 | 1195.51 | 01-SEP-07:02 | 0.00 |
| October | 0.364543E+10 | 0.932417E+09 | 602.06 | 0.292131E+10 | 0.724128E+09 | 0.00 | 1.00 | 01-OCT-09:52 | 0.00 | 01-OCT-05:15 | 5598.13 | 22-OCT-09:02 | 5124.32 | 17-OCT-16:42 | 2343.06 | 22-OCT-09:15 | 1202.51 | 12-OCT-09:02 | 0.00 |
| November | 0.224258E+10 | 0.562830E+09 | 479.36 | 0.195072E+10 | 0.291856E+09 | 0.00 | 1.00 | 01-NOV-07:32 | 0.00 | 01-NOV-05:13 | 5621.59 | 29-NOV-11:52 | 5173.40 | 26-NOV-13:52 | 2389.62 | 29-NOV-11:55 | 1208.07 | 29-NOV-12:52 | 0.00 |
| December | 0.176929E+10 | 0.445909E+09 | 514.11 | 0.156063E+10 | 0.208663E+09 | 0.00 | 1.00 | 01-DEC-11:32 | 0.00 | 01-DEC-09:45 | 5607.94 | 12-DEC-10:22 | 5148.47 | 17-DEC-13:42 | 2322.14 | 12-DEC-10:25 | 1191.09 | 14-DEC-11:55 | 0.00 |
| Annual Sum or Average | 0.308950E+11 | 0.796443E+10 | 6762.04 | 0.242726E+11 | 0.662240E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.107669E+10 | 0.271312E+09 | 384.55 | 0.893254E+09 | 0.132838E+09 | 0.00 | 1.00 | 0.00 | 5512.68 | 4076.36 | 1850.00 | 1176.59 | 0.00 | ||||||
| Maximum of Months | 0.404819E+10 | 0.105755E+10 | 724.47 | 0.305131E+10 | 0.105617E+10 | 0.00 | 1.00 | 0.00 | 5647.31 | 5173.40 | 2553.58 | 1255.67 | 0.00 |
Report: DXReportMonthly
For: SPLIT GS2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.130555E+10 | 0.330463E+09 | 518.07 | 0.117149E+10 | 0.134051E+09 | 0.00 | 1.00 | 01-JAN-10:52 | 0.00 | 01-JAN-06:13 | 5602.20 | 31-JAN-11:02 | 5169.46 | 15-JAN-18:02 | 2070.30 | 31-JAN-11:05 | 1186.71 | 17-JAN-13:12 | 0.00 |
| February | 0.113356E+10 | 0.283555E+09 | 389.49 | 0.962020E+09 | 0.171536E+09 | 0.00 | 1.00 | 01-FEB-13:22 | 0.00 | 01-FEB-06:13 | 5559.28 | 02-FEB-22:52 | 5144.61 | 08-FEB-12:42 | 1859.84 | 02-FEB-22:53 | 1208.86 | 01-FEB-14:42 | 0.00 |
| March | 0.111563E+10 | 0.281102E+09 | 384.91 | 0.928819E+09 | 0.186815E+09 | 0.00 | 1.00 | 01-MAR-07:53 | 0.00 | 01-MAR-07:00 | 5675.24 | 18-MAR-09:32 | 5143.56 | 24-MAR-12:32 | 2501.33 | 18-MAR-09:33 | 1210.05 | 27-MAR-11:02 | 0.00 |
| April | 0.165712E+10 | 0.421478E+09 | 429.18 | 0.134250E+10 | 0.314628E+09 | 0.00 | 1.00 | 01-APR-11:22 | 0.00 | 01-APR-05:15 | 5704.44 | 30-APR-11:02 | 5144.58 | 16-APR-13:32 | 2572.26 | 30-APR-11:05 | 1230.51 | 24-APR-11:52 | 0.00 |
| May | 0.340360E+10 | 0.888742E+09 | 688.99 | 0.259067E+10 | 0.812922E+09 | 0.00 | 1.00 | 02-MAY-07:52 | 0.00 | 02-MAY-05:15 | 5615.26 | 23-MAY-06:52 | 4291.62 | 31-MAY-21:52 | 2200.66 | 23-MAY-06:53 | 1208.61 | 16-MAY-06:52 | 0.00 |
| June | 0.354445E+10 | 0.933944E+09 | 691.19 | 0.269341E+10 | 0.851042E+09 | 0.00 | 1.00 | 01-JUN-07:32 | 0.00 | 01-JUN-05:15 | 5611.60 | 06-JUN-07:42 | 4156.80 | 01-JUN-14:02 | 2121.49 | 06-JUN-07:43 | 1265.93 | 01-JUN-14:02 | 0.00 |
| July | 0.417187E+10 | 0.109388E+10 | 724.94 | 0.308699E+10 | 0.108488E+10 | 0.00 | 1.00 | 11-JUL-21:22 | 0.00 | 11-JUL-19:33 | 5578.87 | 12-JUL-21:52 | 4190.05 | 12-JUL-15:32 | 1960.47 | 12-JUL-21:53 | 1208.60 | 12-JUL-06:52 | 0.00 |
| August | 0.433793E+10 | 0.113120E+10 | 704.67 | 0.331827E+10 | 0.101966E+10 | 0.00 | 1.00 | 01-AUG-06:52 | 0.00 | 01-AUG-05:15 | 5639.83 | 29-AUG-08:62 | 4223.90 | 16-AUG-16:12 | 2307.69 | 29-AUG-08:05 | 1216.36 | 27-AUG-07:42 | 0.00 |
| September | 0.408850E+10 | 0.104604E+10 | 634.76 | 0.313515E+10 | 0.953354E+09 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-05:43 | 5654.02 | 26-SEP-09:32 | 4448.34 | 06-SEP-20:02 | 2394.86 | 05-SEP-08:45 | 1205.65 | 01-SEP-07:02 | 0.00 |
| October | 0.388118E+10 | 0.990833E+09 | 602.24 | 0.314314E+10 | 0.738041E+09 | 0.00 | 1.00 | 01-OCT-09:52 | 0.00 | 01-OCT-05:15 | 5625.31 | 21-OCT-07:42 | 5172.56 | 17-OCT-16:42 | 2232.34 | 21-OCT-07:45 | 1212.74 | 12-OCT-09:02 | 0.00 |
| November | 0.234382E+10 | 0.587739E+09 | 479.52 | 0.204748E+10 | 0.296334E+09 | 0.00 | 1.00 | 01-NOV-07:32 | 0.00 | 01-NOV-05:13 | 5666.13 | 29-NOV-11:52 | 5223.49 | 26-NOV-13:52 | 2395.12 | 29-NOV-11:55 | 1218.48 | 29-NOV-12:52 | 0.00 |
| December | 0.182427E+10 | 0.459441E+09 | 510.70 | 0.161354E+10 | 0.210727E+09 | 0.00 | 1.00 | 01-DEC-11:32 | 0.00 | 01-DEC-09:45 | 5635.67 | 13-DEC-10:52 | 5230.45 | 17-DEC-13:42 | 2275.05 | 13-DEC-10:55 | 1200.17 | 14-DEC-11:43 | 0.00 |
| Annual Sum or Average | 0.328075E+11 | 0.844842E+10 | 6758.67 | 0.260335E+11 | 0.677399E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.111563E+10 | 0.281102E+09 | 384.91 | 0.928819E+09 | 0.134051E+09 | 0.00 | 1.00 | 0.00 | 5559.28 | 4156.80 | 1859.84 | 1186.71 | 0.00 | ||||||
| Maximum of Months | 0.433793E+10 | 0.113120E+10 | 724.94 | 0.331827E+10 | 0.108488E+10 | 0.00 | 1.00 | 0.00 | 5704.44 | 5230.45 | 2572.26 | 1265.93 | 0.00 |
Report: DXReportMonthly
For: SPLIT MSW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.255668E+10 | 0.644692E+09 | 396.07 | 0.227184E+10 | 0.284841E+09 | 0.00 | 1.00 | 01-JAN-10:52 | 0.00 | 01-JAN-06:13 | 14119.57 | 31-JAN-11:02 | 13105.57 | 15-JAN-16:42 | 5391.90 | 31-JAN-11:03 | 2978.94 | 17-JAN-13:12 | 0.00 |
| February | 0.287732E+10 | 0.718925E+09 | 363.46 | 0.247957E+10 | 0.397751E+09 | 0.00 | 1.00 | 01-FEB-13:22 | 0.00 | 01-FEB-06:13 | 14009.36 | 02-FEB-22:52 | 12981.30 | 09-FEB-16:02 | 4969.58 | 02-FEB-22:53 | 3033.50 | 01-FEB-14:42 | 0.00 |
| March | 0.313754E+10 | 0.791189E+09 | 403.38 | 0.268463E+10 | 0.452913E+09 | 0.00 | 1.00 | 01-MAR-19:42 | 0.00 | 01-MAR-07:00 | 14247.02 | 18-MAR-09:32 | 12965.10 | 15-MAR-14:32 | 6089.84 | 18-MAR-09:33 | 3037.35 | 27-MAR-11:02 | 0.00 |
| April | 0.477004E+10 | 0.121512E+10 | 454.12 | 0.400842E+10 | 0.761619E+09 | 0.00 | 1.00 | 01-APR-11:22 | 0.00 | 01-APR-05:15 | 14329.22 | 30-APR-11:02 | 12962.37 | 16-APR-12:02 | 6411.11 | 30-APR-11:03 | 3088.61 | 24-APR-11:52 | 0.00 |
| May | 0.827684E+10 | 0.217385E+10 | 691.38 | 0.642405E+10 | 0.185279E+10 | 0.00 | 1.00 | 02-MAY-07:52 | 0.00 | 02-MAY-05:15 | 14221.09 | 23-MAY-06:52 | 10875.15 | 27-MAY-18:52 | 6226.29 | 23-MAY-06:53 | 3033.68 | 16-MAY-06:52 | 0.00 |
| June | 0.842517E+10 | 0.223555E+10 | 691.94 | 0.654136E+10 | 0.188381E+10 | 0.00 | 1.00 | 01-JUN-07:32 | 0.00 | 01-JUN-05:15 | 14149.75 | 06-JUN-07:42 | 10242.66 | 01-JUN-14:02 | 5742.36 | 06-JUN-07:43 | 3181.36 | 01-JUN-14:02 | 0.00 |
| July | 0.923079E+10 | 0.244049E+10 | 724.92 | 0.686804E+10 | 0.236275E+10 | 0.00 | 1.00 | 11-JUL-21:22 | 0.00 | 11-JUL-19:33 | 14057.86 | 31-JUL-12:22 | 10723.28 | 12-JUL-17:32 | 5446.09 | 12-JUL-06:53 | 3033.72 | 12-JUL-06:53 | 0.00 |
| August | 0.912369E+10 | 0.240264E+10 | 702.84 | 0.691442E+10 | 0.220926E+10 | 0.00 | 1.00 | 01-AUG-06:52 | 0.00 | 01-AUG-05:15 | 14372.50 | 29-AUG-08:62 | 10496.57 | 16-AUG-16:12 | 6759.19 | 29-AUG-08:03 | 3053.41 | 27-AUG-07:43 | 0.00 |
| September | 0.839389E+10 | 0.216908E+10 | 632.35 | 0.633546E+10 | 0.205843E+10 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-05:43 | 14543.54 | 05-SEP-08:42 | 11182.30 | 06-SEP-20:02 | 7535.41 | 05-SEP-08:45 | 3026.75 | 01-SEP-07:02 | 0.00 |
| October | 0.790153E+10 | 0.203717E+10 | 602.41 | 0.629517E+10 | 0.160637E+10 | 0.00 | 1.00 | 01-OCT-09:52 | 0.00 | 01-OCT-05:15 | 14372.13 | 21-OCT-07:42 | 13044.66 | 17-OCT-16:42 | 6651.33 | 21-OCT-07:43 | 3045.24 | 12-OCT-09:02 | 0.00 |
| November | 0.449743E+10 | 0.113316E+10 | 476.11 | 0.388143E+10 | 0.616000E+09 | 0.00 | 1.00 | 01-NOV-07:32 | 0.00 | 01-NOV-05:13 | 14400.38 | 29-NOV-11:52 | 13097.68 | 26-NOV-13:52 | 6780.62 | 29-NOV-11:55 | 3058.44 | 29-NOV-12:53 | 0.00 |
| December | 0.341450E+10 | 0.859650E+09 | 440.78 | 0.297036E+10 | 0.444149E+09 | 0.00 | 1.00 | 01-DEC-11:32 | 0.00 | 01-DEC-09:45 | 14389.91 | 12-DEC-10:22 | 13118.43 | 17-DEC-13:42 | 6835.81 | 12-DEC-10:23 | 3012.08 | 14-DEC-11:43 | 0.00 |
| Annual Sum or Average | 0.726054E+11 | 0.188215E+11 | 6579.77 | 0.576747E+11 | 0.149307E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.255668E+10 | 0.644692E+09 | 363.46 | 0.227184E+10 | 0.284841E+09 | 0.00 | 1.00 | 0.00 | 14009.36 | 10242.66 | 4969.58 | 2978.94 | 0.00 | ||||||
| Maximum of Months | 0.923079E+10 | 0.244049E+10 | 724.92 | 0.691442E+10 | 0.236275E+10 | 0.00 | 1.00 | 0.00 | 14543.54 | 13118.43 | 7535.41 | 3181.36 | 0.00 |
Report: DXReportMonthly
For: SPLIT MNW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.868833E+09 | 0.216455E+09 | 152.59 | 0.677385E+09 | 0.191447E+09 | 0.00 | 1.00 | 01-JAN-12:42 | 0.00 | 01-JAN-06:03 | 13539.10 | 31-JAN-11:22 | 11682.64 | 02-JAN-22:12 | 5353.57 | 31-JAN-11:23 | 2867.01 | 19-JAN-11:23 | 0.00 |
| February | 0.143391E+10 | 0.358797E+09 | 227.62 | 0.114108E+10 | 0.292830E+09 | 0.00 | 1.00 | 01-FEB-14:12 | 0.00 | 01-FEB-06:13 | 13489.47 | 02-FEB-22:52 | 11233.60 | 25-FEB-19:42 | 5214.68 | 02-FEB-22:53 | 2902.14 | 21-FEB-13:52 | 0.00 |
| March | 0.223499E+10 | 0.564558E+09 | 328.12 | 0.182384E+10 | 0.411148E+09 | 0.00 | 1.00 | 01-MAR-19:42 | 0.00 | 01-MAR-07:00 | 13569.68 | 18-MAR-09:42 | 12335.08 | 04-MAR-22:52 | 5571.85 | 18-MAR-09:43 | 2885.03 | 26-MAR-10:02 | 0.00 |
| April | 0.420101E+10 | 0.107151E+10 | 437.06 | 0.347013E+10 | 0.730882E+09 | 0.00 | 1.00 | 01-APR-11:52 | 0.00 | 01-APR-05:15 | 13690.24 | 24-APR-10:42 | 12360.61 | 16-APR-20:42 | 5963.09 | 24-APR-10:43 | 2955.47 | 24-APR-11:53 | 0.00 |
| May | 0.823028E+10 | 0.215652E+10 | 691.99 | 0.637606E+10 | 0.185422E+10 | 0.00 | 1.00 | 02-MAY-07:52 | 0.00 | 02-MAY-05:15 | 13598.27 | 23-MAY-06:52 | 10449.53 | 27-MAY-18:52 | 5896.06 | 23-MAY-06:53 | 2902.84 | 16-MAY-06:52 | 0.00 |
| June | 0.858038E+10 | 0.227050E+10 | 692.81 | 0.667741E+10 | 0.190297E+10 | 0.00 | 1.00 | 01-JUN-07:32 | 0.00 | 01-JUN-05:15 | 13568.17 | 06-JUN-07:42 | 9760.47 | 01-JUN-14:02 | 5568.75 | 06-JUN-07:43 | 3045.31 | 01-JUN-14:02 | 0.00 |
| July | 0.926616E+10 | 0.244408E+10 | 725.10 | 0.690165E+10 | 0.236451E+10 | 0.00 | 1.00 | 11-JUL-21:22 | 0.00 | 11-JUL-19:33 | 13469.49 | 31-JUL-12:22 | 10212.20 | 12-JUL-16:32 | 5154.96 | 12-JUL-06:53 | 2902.88 | 12-JUL-06:53 | 0.00 |
| August | 0.881694E+10 | 0.231728E+10 | 703.20 | 0.662349E+10 | 0.219345E+10 | 0.00 | 1.00 | 01-AUG-06:52 | 0.00 | 01-AUG-05:15 | 13732.90 | 29-AUG-08:62 | 9910.83 | 16-AUG-16:12 | 6380.84 | 29-AUG-08:03 | 2921.79 | 27-AUG-07:43 | 0.00 |
| September | 0.764752E+10 | 0.197367E+10 | 629.23 | 0.564655E+10 | 0.200098E+10 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-05:43 | 13954.20 | 05-SEP-08:42 | 10664.62 | 06-SEP-20:02 | 7396.47 | 05-SEP-08:45 | 2896.28 | 01-SEP-07:02 | 0.00 |
| October | 0.632271E+10 | 0.163525E+10 | 576.97 | 0.483011E+10 | 0.149260E+10 | 0.00 | 1.00 | 01-OCT-10:52 | 0.00 | 01-OCT-05:15 | 13812.94 | 21-OCT-08:62 | 12373.35 | 17-OCT-16:32 | 6749.90 | 21-OCT-08:03 | 2917.01 | 10-OCT-09:13 | 0.00 |
| November | 0.255172E+10 | 0.647905E+09 | 384.96 | 0.203711E+10 | 0.514605E+09 | 0.00 | 1.00 | 01-NOV-07:42 | 0.00 | 01-NOV-05:13 | 13831.86 | 29-NOV-11:52 | 12415.47 | 19-NOV-18:12 | 6725.08 | 29-NOV-11:53 | 2926.07 | 29-NOV-12:53 | 0.00 |
| December | 0.160812E+10 | 0.404672E+09 | 244.62 | 0.125574E+10 | 0.352375E+09 | 0.00 | 1.00 | 01-DEC-14:42 | 0.00 | 01-DEC-09:35 | 13829.32 | 12-DEC-11:12 | 12371.72 | 01-DEC-17:12 | 6713.87 | 12-DEC-11:13 | 2881.02 | 09-DEC-10:42 | 0.00 |
| Annual Sum or Average | 0.617626E+11 | 0.160612E+11 | 5794.26 | 0.474606E+11 | 0.143020E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.868833E+09 | 0.216455E+09 | 152.59 | 0.677385E+09 | 0.191447E+09 | 0.00 | 1.00 | 0.00 | 13469.49 | 9760.47 | 5154.96 | 2867.01 | 0.00 | ||||||
| Maximum of Months | 0.926616E+10 | 0.244408E+10 | 725.10 | 0.690165E+10 | 0.236451E+10 | 0.00 | 1.00 | 0.00 | 13954.20 | 12415.47 | 7396.47 | 3045.31 | 0.00 |
Report: DXReportMonthly
For: SPLIT MSE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.251769E+10 | 0.634254E+09 | 403.55 | 0.223712E+10 | 0.280569E+09 | 0.00 | 1.00 | 01-JAN-10:52 | 0.00 | 01-JAN-06:13 | 13168.20 | 31-JAN-11:02 | 12092.10 | 07-JAN-16:32 | 5007.31 | 31-JAN-11:03 | 2778.18 | 17-JAN-13:12 | 0.00 |
| February | 0.280437E+10 | 0.699566E+09 | 364.06 | 0.241552E+10 | 0.388847E+09 | 0.00 | 1.00 | 01-FEB-13:22 | 0.00 | 01-FEB-06:13 | 13076.63 | 02-FEB-22:52 | 12083.38 | 19-FEB-12:12 | 4662.01 | 02-FEB-22:53 | 2829.74 | 01-FEB-14:42 | 0.00 |
| March | 0.318062E+10 | 0.799838E+09 | 402.84 | 0.272578E+10 | 0.454842E+09 | 0.00 | 1.00 | 01-MAR-19:42 | 0.00 | 01-MAR-07:00 | 13286.81 | 18-MAR-09:32 | 12091.18 | 15-MAR-14:32 | 5660.90 | 18-MAR-09:33 | 2832.79 | 27-MAR-11:02 | 0.00 |
| April | 0.473681E+10 | 0.120295E+10 | 454.88 | 0.397924E+10 | 0.757568E+09 | 0.00 | 1.00 | 01-APR-11:22 | 0.00 | 01-APR-05:15 | 13362.09 | 30-APR-11:02 | 12099.36 | 16-APR-20:42 | 5972.67 | 30-APR-11:03 | 2880.44 | 24-APR-11:52 | 0.00 |
| May | 0.845065E+10 | 0.221052E+10 | 694.99 | 0.658021E+10 | 0.187044E+10 | 0.00 | 1.00 | 02-MAY-07:52 | 0.00 | 02-MAY-05:15 | 13266.95 | 23-MAY-06:52 | 10325.35 | 13-MAY-12:52 | 5787.87 | 23-MAY-06:53 | 2829.38 | 16-MAY-06:52 | 0.00 |
| June | 0.853809E+10 | 0.225734E+10 | 693.58 | 0.664357E+10 | 0.189452E+10 | 0.00 | 1.00 | 01-JUN-07:32 | 0.00 | 01-JUN-05:15 | 13210.81 | 06-JUN-07:42 | 9710.05 | 01-JUN-14:02 | 5340.96 | 06-JUN-07:43 | 2963.81 | 01-JUN-14:02 | 0.00 |
| July | 0.941483E+10 | 0.248084E+10 | 725.51 | 0.703887E+10 | 0.237597E+10 | 0.00 | 1.00 | 11-JUL-21:22 | 0.00 | 11-JUL-19:33 | 13109.92 | 12-JUL-21:52 | 9884.10 | 12-JUL-15:32 | 5055.43 | 12-JUL-06:53 | 2829.39 | 12-JUL-06:53 | 0.00 |
| August | 0.916107E+10 | 0.240400E+10 | 704.20 | 0.694840E+10 | 0.221267E+10 | 0.00 | 1.00 | 01-AUG-06:52 | 0.00 | 01-AUG-05:15 | 13410.64 | 29-AUG-08:62 | 9780.47 | 16-AUG-16:12 | 6275.92 | 29-AUG-08:05 | 2847.69 | 27-AUG-07:43 | 0.00 |
| September | 0.838706E+10 | 0.215959E+10 | 632.99 | 0.632959E+10 | 0.205747E+10 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-05:43 | 13567.75 | 05-SEP-08:42 | 10308.33 | 06-SEP-20:02 | 7000.71 | 05-SEP-08:45 | 2823.00 | 01-SEP-07:02 | 0.00 |
| October | 0.785016E+10 | 0.201600E+10 | 603.09 | 0.624417E+10 | 0.160599E+10 | 0.00 | 1.00 | 01-OCT-09:52 | 0.00 | 01-OCT-05:15 | 13413.69 | 21-OCT-07:42 | 12075.48 | 17-OCT-18:12 | 6247.29 | 21-OCT-07:45 | 2840.08 | 12-OCT-09:02 | 0.00 |
| November | 0.447821E+10 | 0.112512E+10 | 475.70 | 0.386577E+10 | 0.612438E+09 | 0.00 | 1.00 | 01-NOV-07:32 | 0.00 | 01-NOV-05:13 | 13424.29 | 29-NOV-11:52 | 12238.32 | 26-NOV-13:52 | 6279.70 | 29-NOV-11:55 | 2852.43 | 29-NOV-12:53 | 0.00 |
| December | 0.328353E+10 | 0.824771E+09 | 436.55 | 0.284638E+10 | 0.437150E+09 | 0.00 | 1.00 | 01-DEC-11:32 | 0.00 | 01-DEC-09:45 | 13419.56 | 12-DEC-10:22 | 12271.20 | 17-DEC-13:42 | 6414.60 | 12-DEC-10:23 | 2809.62 | 14-DEC-11:45 | 0.00 |
| Annual Sum or Average | 0.728031E+11 | 0.188148E+11 | 6591.94 | 0.578546E+11 | 0.149485E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.251769E+10 | 0.634254E+09 | 364.06 | 0.223712E+10 | 0.280569E+09 | 0.00 | 1.00 | 0.00 | 13076.63 | 9710.05 | 4662.01 | 2778.18 | 0.00 | ||||||
| Maximum of Months | 0.941483E+10 | 0.248084E+10 | 725.51 | 0.703887E+10 | 0.237597E+10 | 0.00 | 1.00 | 0.00 | 13567.75 | 12271.20 | 7000.71 | 2963.81 | 0.00 |
Report: DXReportMonthly
For: SPLIT MNE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.808513E+09 | 0.200871E+09 | 140.24 | 0.622536E+09 | 0.185977E+09 | 0.00 | 1.00 | 01-JAN-12:42 | 0.00 | 01-JAN-06:03 | 12594.79 | 30-JAN-22:42 | 10815.95 | 02-JAN-22:12 | 5079.37 | 30-JAN-22:43 | 2665.57 | 19-JAN-11:23 | 0.00 |
| February | 0.134394E+10 | 0.335973E+09 | 230.27 | 0.106070E+10 | 0.283237E+09 | 0.00 | 1.00 | 01-FEB-14:12 | 0.00 | 01-FEB-06:13 | 12587.98 | 02-FEB-22:52 | 10196.09 | 26-FEB-19:02 | 5106.68 | 02-FEB-22:53 | 2697.91 | 21-FEB-13:52 | 0.00 |
| March | 0.225796E+10 | 0.568589E+09 | 334.03 | 0.184091E+10 | 0.417051E+09 | 0.00 | 1.00 | 01-MAR-19:42 | 0.00 | 01-MAR-07:00 | 12615.95 | 18-MAR-09:42 | 11454.63 | 24-MAR-14:02 | 5154.14 | 18-MAR-09:43 | 2681.53 | 26-MAR-10:02 | 0.00 |
| April | 0.418286E+10 | 0.106354E+10 | 441.67 | 0.345005E+10 | 0.732811E+09 | 0.00 | 1.00 | 01-APR-11:52 | 0.00 | 01-APR-05:15 | 12704.59 | 30-APR-11:52 | 11518.09 | 16-APR-20:42 | 5525.99 | 24-APR-10:45 | 2747.48 | 24-APR-11:52 | 0.00 |
| May | 0.840885E+10 | 0.219389E+10 | 695.71 | 0.653269E+10 | 0.187616E+10 | 0.00 | 1.00 | 02-MAY-07:52 | 0.00 | 02-MAY-05:15 | 12643.95 | 23-MAY-06:52 | 9881.44 | 13-MAY-12:52 | 5467.10 | 23-MAY-06:53 | 2698.62 | 16-MAY-06:52 | 0.00 |
| June | 0.869666E+10 | 0.229219E+10 | 694.39 | 0.677984E+10 | 0.191682E+10 | 0.00 | 1.00 | 01-JUN-07:32 | 0.00 | 01-JUN-05:15 | 12625.57 | 06-JUN-07:42 | 9207.67 | 01-JUN-14:02 | 5167.46 | 06-JUN-07:43 | 2827.95 | 01-JUN-14:02 | 0.00 |
| July | 0.945462E+10 | 0.248473E+10 | 725.47 | 0.707296E+10 | 0.238166E+10 | 0.00 | 1.00 | 11-JUL-21:22 | 0.00 | 11-JUL-19:33 | 12489.84 | 12-JUL-21:52 | 9265.21 | 12-JUL-15:42 | 4773.67 | 12-JUL-06:53 | 2698.63 | 12-JUL-06:53 | 0.00 |
| August | 0.885915E+10 | 0.232008E+10 | 703.48 | 0.665833E+10 | 0.220082E+10 | 0.00 | 1.00 | 01-AUG-06:52 | 0.00 | 01-AUG-05:15 | 12771.90 | 29-AUG-08:62 | 9187.94 | 16-AUG-16:12 | 5907.80 | 29-AUG-08:05 | 2716.18 | 27-AUG-07:43 | 0.00 |
| September | 0.764746E+10 | 0.196689E+10 | 630.42 | 0.564323E+10 | 0.200423E+10 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-05:43 | 12975.59 | 05-SEP-08:42 | 9769.67 | 06-SEP-20:02 | 6855.08 | 05-SEP-08:45 | 2692.58 | 01-SEP-07:02 | 0.00 |
| October | 0.627659E+10 | 0.161739E+10 | 579.69 | 0.478025E+10 | 0.149635E+10 | 0.00 | 1.00 | 01-OCT-10:52 | 0.00 | 01-OCT-05:15 | 12852.88 | 21-OCT-08:62 | 11504.49 | 17-OCT-16:32 | 6246.86 | 21-OCT-08:05 | 2711.80 | 10-OCT-09:12 | 0.00 |
| November | 0.252640E+10 | 0.639946E+09 | 387.69 | 0.201389E+10 | 0.512516E+09 | 0.00 | 1.00 | 01-NOV-07:42 | 0.00 | 01-NOV-05:13 | 12850.64 | 29-NOV-11:52 | 11539.29 | 19-NOV-16:32 | 6242.30 | 29-NOV-11:55 | 2720.17 | 29-NOV-12:53 | 0.00 |
| December | 0.149743E+10 | 0.375661E+09 | 242.53 | 0.115323E+10 | 0.344199E+09 | 0.00 | 1.00 | 01-DEC-14:42 | 0.00 | 01-DEC-09:45 | 12857.10 | 12-DEC-11:12 | 11428.98 | 01-DEC-17:12 | 6302.37 | 12-DEC-11:15 | 2678.84 | 09-DEC-10:42 | 0.00 |
| Annual Sum or Average | 0.619604E+11 | 0.160598E+11 | 5805.60 | 0.476086E+11 | 0.143518E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.808513E+09 | 0.200871E+09 | 140.24 | 0.622536E+09 | 0.185977E+09 | 0.00 | 1.00 | 0.00 | 12489.84 | 9187.94 | 4773.67 | 2665.57 | 0.00 | ||||||
| Maximum of Months | 0.945462E+10 | 0.248473E+10 | 725.47 | 0.707296E+10 | 0.238166E+10 | 0.00 | 1.00 | 0.00 | 12975.59 | 11539.29 | 6855.08 | 2827.95 | 0.00 |
Report: DXReportMonthly
For: SPLIT MN1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.959983E+09 | 0.240013E+09 | 246.36 | 0.767138E+09 | 0.192846E+09 | 0.00 | 1.00 | 01-JAN-12:42 | 0.00 | 01-JAN-06:13 | 11403.06 | 19-JAN-22:52 | 10310.20 | 28-JAN-20:12 | 4580.07 | 19-JAN-22:53 | 2412.54 | 19-JAN-11:23 | 0.00 |
| February | 0.146265E+10 | 0.366365E+09 | 280.31 | 0.117010E+10 | 0.292550E+09 | 0.00 | 1.00 | 01-FEB-14:12 | 0.00 | 01-FEB-06:13 | 11378.16 | 02-FEB-22:52 | 10258.23 | 08-FEB-21:02 | 4462.26 | 02-FEB-22:53 | 2442.02 | 21-FEB-13:52 | 0.00 |
| March | 0.219897E+10 | 0.554834E+09 | 392.89 | 0.180270E+10 | 0.396268E+09 | 0.00 | 1.00 | 01-MAR-19:42 | 0.00 | 01-MAR-07:00 | 11408.41 | 18-MAR-09:42 | 10374.00 | 04-MAR-22:52 | 4767.72 | 18-MAR-09:45 | 2427.62 | 26-MAR-10:02 | 0.00 |
| April | 0.367831E+10 | 0.934010E+09 | 432.47 | 0.299804E+10 | 0.680270E+09 | 0.00 | 1.00 | 01-APR-11:52 | 0.00 | 01-APR-05:15 | 11522.90 | 24-APR-10:42 | 10407.45 | 16-APR-20:42 | 5169.40 | 24-APR-10:45 | 2486.95 | 24-APR-11:53 | 0.00 |
| May | 0.702491E+10 | 0.183190E+10 | 691.49 | 0.533354E+10 | 0.169137E+10 | 0.00 | 1.00 | 02-MAY-07:52 | 0.00 | 02-MAY-05:15 | 11429.47 | 23-MAY-06:52 | 8656.49 | 31-MAY-21:52 | 4889.76 | 23-MAY-06:53 | 2442.73 | 16-MAY-06:52 | 0.00 |
| June | 0.724983E+10 | 0.190971E+10 | 691.44 | 0.549938E+10 | 0.175045E+10 | 0.00 | 1.00 | 01-JUN-07:32 | 0.00 | 01-JUN-05:15 | 11422.51 | 06-JUN-07:42 | 8165.72 | 01-JUN-14:02 | 4757.11 | 06-JUN-07:43 | 2563.53 | 01-JUN-14:02 | 0.00 |
| July | 0.791132E+10 | 0.207660E+10 | 725.13 | 0.574313E+10 | 0.216819E+10 | 0.00 | 1.00 | 11-JUL-21:22 | 0.00 | 11-JUL-19:33 | 11356.17 | 12-JUL-21:52 | 8003.83 | 12-JUL-15:42 | 4430.28 | 12-JUL-21:55 | 2442.74 | 12-JUL-06:53 | 0.00 |
| August | 0.747335E+10 | 0.195509E+10 | 702.21 | 0.548074E+10 | 0.199261E+10 | 0.00 | 1.00 | 01-AUG-06:52 | 0.00 | 01-AUG-05:15 | 11538.98 | 29-AUG-08:62 | 8111.47 | 16-AUG-16:12 | 5392.18 | 29-AUG-08:05 | 2458.60 | 27-AUG-07:43 | 0.00 |
| September | 0.659102E+10 | 0.169111E+10 | 625.85 | 0.476390E+10 | 0.182712E+10 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-05:43 | 11719.68 | 05-SEP-08:42 | 8751.12 | 06-SEP-20:02 | 6159.07 | 05-SEP-08:45 | 2437.33 | 01-SEP-07:02 | 0.00 |
| October | 0.545457E+10 | 0.140411E+10 | 575.00 | 0.410013E+10 | 0.135444E+10 | 0.00 | 1.00 | 01-OCT-10:52 | 0.00 | 01-OCT-05:15 | 11602.51 | 21-OCT-08:62 | 10418.15 | 17-OCT-16:32 | 5659.33 | 21-OCT-08:05 | 2454.66 | 10-OCT-09:12 | 0.00 |
| November | 0.253935E+10 | 0.643251E+09 | 414.12 | 0.204460E+10 | 0.494748E+09 | 0.00 | 1.00 | 01-NOV-07:42 | 0.00 | 01-NOV-05:13 | 11622.25 | 29-NOV-11:52 | 10426.70 | 19-NOV-18:12 | 5609.95 | 29-NOV-11:55 | 2462.24 | 29-NOV-12:53 | 0.00 |
| December | 0.169330E+10 | 0.426241E+09 | 354.75 | 0.134730E+10 | 0.346003E+09 | 0.00 | 1.00 | 01-DEC-14:42 | 0.00 | 01-DEC-09:35 | 11628.44 | 12-DEC-11:12 | 10360.30 | 01-DEC-17:12 | 5590.59 | 12-DEC-11:15 | 2424.33 | 09-DEC-10:42 | 0.00 |
| Annual Sum or Average | 0.542376E+11 | 0.140332E+11 | 6132.02 | 0.410507E+11 | 0.131869E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.959983E+09 | 0.240013E+09 | 246.36 | 0.767138E+09 | 0.192846E+09 | 0.00 | 1.00 | 0.00 | 11356.17 | 8003.83 | 4430.28 | 2412.54 | 0.00 | ||||||
| Maximum of Months | 0.791132E+10 | 0.207660E+10 | 725.13 | 0.574313E+10 | 0.216819E+10 | 0.00 | 1.00 | 0.00 | 11719.68 | 10426.70 | 6159.07 | 2563.53 | 0.00 |
Report: DXReportMonthly
For: SPLIT MN2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.958783E+09 | 0.239717E+09 | 247.54 | 0.766102E+09 | 0.192681E+09 | 0.00 | 1.00 | 01-JAN-12:42 | 0.00 | 01-JAN-06:13 | 11385.00 | 19-JAN-22:52 | 10294.43 | 28-JAN-20:12 | 4574.56 | 19-JAN-22:53 | 2408.72 | 19-JAN-11:23 | 0.00 |
| February | 0.145967E+10 | 0.365651E+09 | 280.58 | 0.116745E+10 | 0.292215E+09 | 0.00 | 1.00 | 01-FEB-14:12 | 0.00 | 01-FEB-06:13 | 11359.91 | 02-FEB-22:52 | 10241.84 | 08-FEB-21:02 | 4460.18 | 02-FEB-22:53 | 2438.18 | 21-FEB-13:52 | 0.00 |
| March | 0.220431E+10 | 0.556128E+09 | 393.61 | 0.180745E+10 | 0.396862E+09 | 0.00 | 1.00 | 01-MAR-19:42 | 0.00 | 01-MAR-07:00 | 11390.41 | 18-MAR-09:42 | 10356.31 | 04-MAR-22:52 | 4760.75 | 18-MAR-09:45 | 2423.82 | 26-MAR-10:02 | 0.00 |
| April | 0.368571E+10 | 0.935826E+09 | 432.54 | 0.300489E+10 | 0.680827E+09 | 0.00 | 1.00 | 01-APR-11:52 | 0.00 | 01-APR-05:15 | 11505.10 | 24-APR-10:42 | 10390.32 | 16-APR-20:42 | 5159.57 | 24-APR-10:45 | 2483.03 | 24-APR-11:53 | 0.00 |
| May | 0.703268E+10 | 0.183381E+10 | 691.46 | 0.534035E+10 | 0.169233E+10 | 0.00 | 1.00 | 02-MAY-07:52 | 0.00 | 02-MAY-05:15 | 11411.47 | 23-MAY-06:52 | 8641.95 | 31-MAY-21:52 | 4882.09 | 23-MAY-06:53 | 2438.88 | 16-MAY-06:52 | 0.00 |
| June | 0.725518E+10 | 0.191101E+10 | 691.44 | 0.550403E+10 | 0.175115E+10 | 0.00 | 1.00 | 01-JUN-07:32 | 0.00 | 01-JUN-05:15 | 11404.72 | 06-JUN-07:42 | 8159.56 | 01-JUN-14:02 | 4751.32 | 06-JUN-07:43 | 2559.43 | 01-JUN-14:02 | 0.00 |
| July | 0.791866E+10 | 0.207841E+10 | 725.13 | 0.574956E+10 | 0.216909E+10 | 0.00 | 1.00 | 11-JUL-21:22 | 0.00 | 11-JUL-19:33 | 11339.97 | 12-JUL-21:52 | 7994.27 | 12-JUL-15:42 | 4429.74 | 12-JUL-21:55 | 2438.89 | 12-JUL-06:53 | 0.00 |
| August | 0.747557E+10 | 0.195558E+10 | 702.24 | 0.548256E+10 | 0.199301E+10 | 0.00 | 1.00 | 01-AUG-06:52 | 0.00 | 01-AUG-05:15 | 11521.00 | 29-AUG-08:62 | 8097.68 | 16-AUG-16:12 | 5381.95 | 29-AUG-08:05 | 2454.73 | 27-AUG-07:43 | 0.00 |
| September | 0.659185E+10 | 0.169124E+10 | 625.85 | 0.476446E+10 | 0.182739E+10 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-05:43 | 11701.26 | 05-SEP-08:42 | 8731.29 | 06-SEP-20:02 | 6149.14 | 05-SEP-08:45 | 2433.50 | 01-SEP-07:02 | 0.00 |
| October | 0.545434E+10 | 0.140399E+10 | 574.67 | 0.409966E+10 | 0.135468E+10 | 0.00 | 1.00 | 01-OCT-10:52 | 0.00 | 01-OCT-05:15 | 11584.45 | 21-OCT-08:62 | 10401.66 | 17-OCT-16:32 | 5650.47 | 21-OCT-08:05 | 2450.79 | 10-OCT-09:12 | 0.00 |
| November | 0.254002E+10 | 0.643369E+09 | 414.19 | 0.204495E+10 | 0.495067E+09 | 0.00 | 1.00 | 01-NOV-07:42 | 0.00 | 01-NOV-05:13 | 11604.09 | 29-NOV-11:52 | 10409.53 | 19-NOV-16:32 | 5600.65 | 29-NOV-11:55 | 2458.36 | 29-NOV-12:53 | 0.00 |
| December | 0.168452E+10 | 0.423998E+09 | 352.98 | 0.133900E+10 | 0.345522E+09 | 0.00 | 1.00 | 01-DEC-14:42 | 0.00 | 01-DEC-09:35 | 11610.09 | 12-DEC-11:12 | 10281.09 | 04-DEC-20:02 | 5582.35 | 12-DEC-11:15 | 2420.52 | 09-DEC-10:42 | 0.00 |
| Annual Sum or Average | 0.542613E+11 | 0.140387E+11 | 6132.23 | 0.410705E+11 | 0.131908E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.958783E+09 | 0.239717E+09 | 247.54 | 0.766102E+09 | 0.192681E+09 | 0.00 | 1.00 | 0.00 | 11339.97 | 7994.27 | 4429.74 | 2408.72 | 0.00 | ||||||
| Maximum of Months | 0.791866E+10 | 0.207841E+10 | 725.13 | 0.574956E+10 | 0.216909E+10 | 0.00 | 1.00 | 0.00 | 11701.26 | 10409.53 | 6149.14 | 2559.43 | 0.00 |
Report: DXReportMonthly
For: SPLIT MS1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.306097E+10 | 0.774784E+09 | 517.90 | 0.277226E+10 | 0.288706E+09 | 0.00 | 1.00 | 01-JAN-10:52 | 0.00 | 01-JAN-06:13 | 12016.05 | 31-JAN-11:02 | 11066.97 | 15-JAN-18:02 | 4443.89 | 31-JAN-11:03 | 2546.12 | 19-JAN-11:15 | 0.00 |
| February | 0.309328E+10 | 0.774577E+09 | 425.56 | 0.269990E+10 | 0.393377E+09 | 0.00 | 1.00 | 01-FEB-13:22 | 0.00 | 01-FEB-06:13 | 11933.02 | 02-FEB-22:52 | 11044.40 | 09-FEB-16:02 | 4130.55 | 02-FEB-22:53 | 2587.61 | 01-FEB-14:42 | 0.00 |
| March | 0.317568E+10 | 0.801009E+09 | 456.90 | 0.273885E+10 | 0.436832E+09 | 0.00 | 1.00 | 01-MAR-07:53 | 0.00 | 01-MAR-07:00 | 12147.68 | 18-MAR-09:32 | 11050.87 | 15-MAR-14:32 | 5265.32 | 18-MAR-09:35 | 2590.58 | 27-MAR-11:02 | 0.00 |
| April | 0.426017E+10 | 0.108135E+10 | 454.80 | 0.354794E+10 | 0.712229E+09 | 0.00 | 1.00 | 01-APR-11:22 | 0.00 | 01-APR-05:15 | 12216.39 | 30-APR-11:02 | 11056.99 | 16-APR-12:02 | 5557.05 | 30-APR-11:05 | 2634.38 | 24-APR-11:52 | 0.00 |
| May | 0.707149E+10 | 0.184972E+10 | 691.29 | 0.538207E+10 | 0.168942E+10 | 0.00 | 1.00 | 02-MAY-07:52 | 0.00 | 02-MAY-05:15 | 12115.69 | 23-MAY-06:52 | 9137.39 | 31-MAY-21:52 | 5235.47 | 23-MAY-06:53 | 2587.50 | 16-MAY-06:52 | 0.00 |
| June | 0.709115E+10 | 0.187412E+10 | 691.25 | 0.536267E+10 | 0.172848E+10 | 0.00 | 1.00 | 01-JUN-07:32 | 0.00 | 01-JUN-05:15 | 12072.39 | 06-JUN-07:42 | 8674.17 | 01-JUN-14:02 | 4963.60 | 06-JUN-07:43 | 2714.14 | 01-JUN-14:02 | 0.00 |
| July | 0.787496E+10 | 0.207326E+10 | 724.89 | 0.571001E+10 | 0.216495E+10 | 0.00 | 1.00 | 11-JUL-21:22 | 0.00 | 11-JUL-19:33 | 12033.49 | 12-JUL-21:52 | 8654.48 | 12-JUL-15:32 | 4647.92 | 12-JUL-06:53 | 2587.51 | 12-JUL-06:53 | 0.00 |
| August | 0.778405E+10 | 0.204207E+10 | 702.72 | 0.577243E+10 | 0.201162E+10 | 0.00 | 1.00 | 01-AUG-06:52 | 0.00 | 01-AUG-05:15 | 12241.88 | 29-AUG-08:62 | 8770.18 | 16-AUG-16:12 | 5787.74 | 29-AUG-08:05 | 2604.16 | 27-AUG-07:43 | 0.00 |
| September | 0.735007E+10 | 0.189046E+10 | 631.05 | 0.545748E+10 | 0.189260E+10 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-05:43 | 12377.43 | 05-SEP-08:42 | 9373.96 | 06-SEP-20:02 | 6337.89 | 05-SEP-08:45 | 2581.73 | 01-SEP-07:02 | 0.00 |
| October | 0.704848E+10 | 0.181006E+10 | 603.86 | 0.557509E+10 | 0.147339E+10 | 0.00 | 1.00 | 01-OCT-09:52 | 0.00 | 01-OCT-05:15 | 12232.30 | 21-OCT-07:42 | 11065.03 | 17-OCT-16:42 | 5650.46 | 20-OCT-08:25 | 2597.33 | 12-OCT-09:02 | 0.00 |
| November | 0.454812E+10 | 0.114256E+10 | 485.78 | 0.395244E+10 | 0.595678E+09 | 0.00 | 1.00 | 01-NOV-07:32 | 0.00 | 01-NOV-05:13 | 12265.10 | 29-NOV-11:52 | 11189.17 | 26-NOV-13:52 | 5667.70 | 29-NOV-11:55 | 2608.59 | 29-NOV-12:53 | 0.00 |
| December | 0.375052E+10 | 0.944906E+09 | 506.36 | 0.331582E+10 | 0.434698E+09 | 0.00 | 1.00 | 01-DEC-11:32 | 0.00 | 01-DEC-09:45 | 12254.90 | 12-DEC-10:22 | 11216.49 | 17-DEC-13:42 | 5669.04 | 12-DEC-10:25 | 2569.44 | 14-DEC-11:45 | 0.00 |
| Annual Sum or Average | 0.661089E+11 | 0.170589E+11 | 6892.37 | 0.522869E+11 | 0.138220E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.306097E+10 | 0.774577E+09 | 425.56 | 0.269990E+10 | 0.288706E+09 | 0.00 | 1.00 | 0.00 | 11933.02 | 8654.48 | 4130.55 | 2546.12 | 0.00 | ||||||
| Maximum of Months | 0.787496E+10 | 0.207326E+10 | 724.89 | 0.577243E+10 | 0.216495E+10 | 0.00 | 1.00 | 0.00 | 12377.43 | 11216.49 | 6337.89 | 2714.14 | 0.00 |
Report: DXReportMonthly
For: SPLIT MS2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.306240E+10 | 0.775119E+09 | 517.47 | 0.277364E+10 | 0.288763E+09 | 0.00 | 1.00 | 01-JAN-10:52 | 0.00 | 01-JAN-06:13 | 12000.22 | 31-JAN-11:02 | 11052.02 | 15-JAN-18:02 | 4438.59 | 31-JAN-11:03 | 2542.75 | 19-JAN-11:15 | 0.00 |
| February | 0.309235E+10 | 0.774318E+09 | 425.65 | 0.269912E+10 | 0.393235E+09 | 0.00 | 1.00 | 01-FEB-13:22 | 0.00 | 01-FEB-06:13 | 11917.44 | 02-FEB-22:52 | 11030.19 | 09-FEB-16:02 | 4126.31 | 02-FEB-22:53 | 2584.22 | 01-FEB-14:42 | 0.00 |
| March | 0.318245E+10 | 0.802677E+09 | 457.76 | 0.274509E+10 | 0.437357E+09 | 0.00 | 1.00 | 01-MAR-07:53 | 0.00 | 01-MAR-07:00 | 12131.72 | 18-MAR-09:32 | 11036.42 | 15-MAR-14:32 | 5258.80 | 18-MAR-09:35 | 2587.17 | 27-MAR-11:02 | 0.00 |
| April | 0.426708E+10 | 0.108303E+10 | 455.37 | 0.355432E+10 | 0.712754E+09 | 0.00 | 1.00 | 01-APR-11:22 | 0.00 | 01-APR-05:15 | 12200.16 | 30-APR-11:02 | 11040.98 | 16-APR-12:02 | 5550.82 | 30-APR-11:05 | 2630.92 | 24-APR-11:52 | 0.00 |
| May | 0.707932E+10 | 0.185168E+10 | 691.29 | 0.538891E+10 | 0.169041E+10 | 0.00 | 1.00 | 02-MAY-07:52 | 0.00 | 02-MAY-05:15 | 12099.73 | 23-MAY-06:52 | 9124.44 | 31-MAY-21:52 | 5228.63 | 23-MAY-06:53 | 2584.10 | 16-MAY-06:52 | 0.00 |
| June | 0.709667E+10 | 0.187550E+10 | 691.25 | 0.536746E+10 | 0.172921E+10 | 0.00 | 1.00 | 01-JUN-07:32 | 0.00 | 01-JUN-05:15 | 12056.72 | 06-JUN-07:42 | 8670.07 | 01-JUN-14:02 | 4958.96 | 06-JUN-07:43 | 2710.50 | 01-JUN-14:02 | 0.00 |
| July | 0.788241E+10 | 0.207514E+10 | 724.89 | 0.571653E+10 | 0.216588E+10 | 0.00 | 1.00 | 11-JUL-21:22 | 0.00 | 11-JUL-19:33 | 12018.85 | 12-JUL-21:52 | 8646.73 | 12-JUL-15:32 | 4642.15 | 12-JUL-06:53 | 2584.11 | 12-JUL-06:53 | 0.00 |
| August | 0.778619E+10 | 0.204255E+10 | 702.55 | 0.577420E+10 | 0.201199E+10 | 0.00 | 1.00 | 01-AUG-06:52 | 0.00 | 01-AUG-05:15 | 12225.97 | 29-AUG-08:62 | 8757.66 | 16-AUG-16:12 | 5778.36 | 29-AUG-08:05 | 2600.73 | 27-AUG-07:43 | 0.00 |
| September | 0.735065E+10 | 0.189051E+10 | 630.89 | 0.545779E+10 | 0.189286E+10 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-05:43 | 12361.18 | 05-SEP-08:42 | 9357.76 | 06-SEP-20:02 | 6329.31 | 05-SEP-08:45 | 2578.33 | 01-SEP-07:02 | 0.00 |
| October | 0.704864E+10 | 0.181000E+10 | 604.09 | 0.557503E+10 | 0.147362E+10 | 0.00 | 1.00 | 01-OCT-09:52 | 0.00 | 01-OCT-05:15 | 12216.34 | 21-OCT-07:42 | 11049.42 | 17-OCT-16:42 | 5644.21 | 20-OCT-08:25 | 2593.91 | 12-OCT-09:02 | 0.00 |
| November | 0.455071E+10 | 0.114313E+10 | 485.43 | 0.395484E+10 | 0.595868E+09 | 0.00 | 1.00 | 01-NOV-07:32 | 0.00 | 01-NOV-05:13 | 12248.65 | 29-NOV-11:52 | 11174.77 | 26-NOV-13:52 | 5659.45 | 29-NOV-11:55 | 2605.16 | 29-NOV-12:53 | 0.00 |
| December | 0.374365E+10 | 0.943111E+09 | 506.30 | 0.330896E+10 | 0.434696E+09 | 0.00 | 1.00 | 01-DEC-11:32 | 0.00 | 01-DEC-09:45 | 12238.72 | 12-DEC-10:22 | 11204.00 | 17-DEC-13:42 | 5662.20 | 12-DEC-10:25 | 2568.27 | 14-DEC-11:55 | 0.00 |
| Annual Sum or Average | 0.661425E+11 | 0.170668E+11 | 6892.93 | 0.523159E+11 | 0.138266E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.306240E+10 | 0.774318E+09 | 425.65 | 0.269912E+10 | 0.288763E+09 | 0.00 | 1.00 | 0.00 | 11917.44 | 8646.73 | 4126.31 | 2542.75 | 0.00 | ||||||
| Maximum of Months | 0.788241E+10 | 0.207514E+10 | 724.89 | 0.577420E+10 | 0.216588E+10 | 0.00 | 1.00 | 0.00 | 12361.18 | 11204.00 | 6329.31 | 2710.50 | 0.00 |
Report: DXReportMonthly
For: SPLIT TSW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.856541E+09 | 0.212062E+09 | 215.00 | 0.740109E+09 | 0.116431E+09 | 0.00 | 1.00 | 01-JAN-10:52 | 0.00 | 01-JAN-04:40 | 7761.68 | 31-JAN-11:02 | 7289.84 | 29-JAN-15:42 | 3144.32 | 31-JAN-11:03 | 1635.51 | 17-JAN-13:12 | 0.00 |
| February | 0.107111E+10 | 0.263561E+09 | 226.73 | 0.909793E+09 | 0.161319E+09 | 0.00 | 1.00 | 01-FEB-13:22 | 0.00 | 01-FEB-06:03 | 7722.03 | 02-FEB-22:52 | 7213.40 | 26-FEB-18:12 | 2878.52 | 02-FEB-22:53 | 1664.74 | 01-FEB-14:42 | 0.00 |
| March | 0.127939E+10 | 0.319874E+09 | 268.01 | 0.107988E+10 | 0.199514E+09 | 0.00 | 1.00 | 02-MAR-19:02 | 0.00 | 01-MAR-07:00 | 7832.22 | 18-MAR-09:32 | 7291.28 | 16-MAR-16:12 | 3542.92 | 18-MAR-09:33 | 1667.50 | 27-MAR-11:02 | 0.00 |
| April | 0.226554E+10 | 0.577114E+09 | 407.27 | 0.190409E+10 | 0.361457E+09 | 0.00 | 1.00 | 01-APR-11:22 | 0.00 | 01-APR-05:15 | 7869.30 | 30-APR-11:02 | 7299.14 | 12-APR-16:42 | 3530.49 | 30-APR-11:03 | 1695.51 | 24-APR-11:52 | 0.00 |
| May | 0.450788E+10 | 0.118828E+10 | 691.32 | 0.354489E+10 | 0.962994E+09 | 0.00 | 1.00 | 02-MAY-07:52 | 0.00 | 02-MAY-05:15 | 7861.50 | 23-MAY-06:52 | 6095.03 | 27-MAY-18:52 | 3545.86 | 23-MAY-06:53 | 1665.35 | 16-MAY-06:53 | 0.00 |
| June | 0.466790E+10 | 0.124261E+10 | 692.14 | 0.369023E+10 | 0.977667E+09 | 0.00 | 1.00 | 01-JUN-07:32 | 0.00 | 01-JUN-05:15 | 7821.53 | 06-JUN-07:42 | 5658.90 | 01-JUN-14:02 | 3329.43 | 06-JUN-07:43 | 1745.59 | 01-JUN-14:02 | 0.00 |
| July | 0.509184E+10 | 0.134996E+10 | 725.14 | 0.385593E+10 | 0.123591E+10 | 0.00 | 1.00 | 11-JUL-21:22 | 0.00 | 11-JUL-19:33 | 7755.83 | 12-JUL-06:52 | 6569.71 | 12-JUL-16:22 | 3193.34 | 12-JUL-06:53 | 1665.33 | 15-JUL-06:52 | 0.00 |
| August | 0.500756E+10 | 0.132227E+10 | 703.66 | 0.385136E+10 | 0.115620E+10 | 0.00 | 1.00 | 01-AUG-06:52 | 0.00 | 01-AUG-05:15 | 7937.68 | 29-AUG-08:62 | 6346.98 | 16-AUG-15:52 | 3879.77 | 29-AUG-08:03 | 1675.91 | 27-AUG-07:43 | 0.00 |
| September | 0.445394E+10 | 0.115379E+10 | 631.40 | 0.338925E+10 | 0.106469E+10 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-05:43 | 8022.78 | 05-SEP-08:42 | 6693.25 | 02-SEP-16:42 | 4250.18 | 05-SEP-08:45 | 1661.74 | 01-SEP-07:02 | 0.00 |
| October | 0.408208E+10 | 0.105430E+10 | 574.04 | 0.325961E+10 | 0.822464E+09 | 0.00 | 1.00 | 01-OCT-09:52 | 0.00 | 01-OCT-05:15 | 7959.71 | 21-OCT-07:42 | 7283.09 | 29-OCT-16:52 | 3915.46 | 21-OCT-07:43 | 1671.64 | 12-OCT-09:02 | 0.00 |
| November | 0.184214E+10 | 0.461091E+09 | 343.92 | 0.156557E+10 | 0.276568E+09 | 0.00 | 1.00 | 01-NOV-07:32 | 0.00 | 01-NOV-05:13 | 7914.24 | 29-NOV-11:52 | 7272.46 | 13-NOV-15:32 | 3708.95 | 29-NOV-11:53 | 1678.95 | 29-NOV-12:53 | 0.00 |
| December | 0.129778E+10 | 0.323146E+09 | 250.84 | 0.110223E+10 | 0.195546E+09 | 0.00 | 1.00 | 01-DEC-11:32 | 0.00 | 01-DEC-02:20 | 7927.75 | 13-DEC-10:52 | 7312.60 | 31-DEC-16:32 | 3953.64 | 12-DEC-10:22 | 1653.13 | 14-DEC-11:43 | 0.00 |
| Annual Sum or Average | 0.364237E+11 | 0.946806E+10 | 5729.48 | 0.288929E+11 | 0.753076E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.856541E+09 | 0.212062E+09 | 215.00 | 0.740109E+09 | 0.116431E+09 | 0.00 | 1.00 | 0.00 | 7722.03 | 5658.90 | 2878.52 | 1635.51 | 0.00 | ||||||
| Maximum of Months | 0.509184E+10 | 0.134996E+10 | 725.14 | 0.385593E+10 | 0.123591E+10 | 0.00 | 1.00 | 0.00 | 8022.78 | 7312.60 | 4250.18 | 1745.59 | 0.00 |
Report: DXReportMonthly
For: SPLIT TNW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.327756E+09 | 80944555.07 | 91.02 | 0.248788E+09 | 78968249.37 | 0.00 | 1.00 | 01-JAN-12:42 | 0.00 | 01-JAN-02:30 | 7550.50 | 31-JAN-11:22 | 6486.46 | 02-JAN-22:12 | 3047.58 | 31-JAN-11:23 | 1595.66 | 19-JAN-11:23 | 0.00 |
| February | 0.516536E+09 | 0.128105E+09 | 144.21 | 0.401905E+09 | 0.114631E+09 | 0.00 | 1.00 | 01-FEB-14:12 | 0.00 | 01-FEB-06:03 | 7525.17 | 02-FEB-22:52 | 6507.35 | 27-FEB-18:22 | 2968.05 | 02-FEB-22:53 | 1615.30 | 21-FEB-13:52 | 0.00 |
| March | 0.904269E+09 | 0.227133E+09 | 217.64 | 0.722939E+09 | 0.181330E+09 | 0.00 | 1.00 | 02-MAR-19:02 | 0.00 | 01-MAR-07:00 | 7570.56 | 18-MAR-09:42 | 6876.13 | 16-MAR-17:22 | 3269.33 | 18-MAR-09:43 | 1606.23 | 26-MAR-10:02 | 0.00 |
| April | 0.197710E+10 | 0.505154E+09 | 388.54 | 0.162950E+10 | 0.347602E+09 | 0.00 | 1.00 | 01-APR-11:52 | 0.00 | 01-APR-05:15 | 7633.99 | 24-APR-10:42 | 7014.33 | 12-APR-15:52 | 3374.48 | 24-APR-10:43 | 1645.19 | 24-APR-11:53 | 0.00 |
| May | 0.448759E+10 | 0.118088E+10 | 693.57 | 0.352101E+10 | 0.966586E+09 | 0.00 | 1.00 | 02-MAY-07:52 | 0.00 | 02-MAY-05:15 | 7622.27 | 23-MAY-06:52 | 5929.89 | 27-MAY-18:52 | 3403.26 | 23-MAY-06:53 | 1615.92 | 16-MAY-06:53 | 0.00 |
| June | 0.474927E+10 | 0.126150E+10 | 694.25 | 0.376034E+10 | 0.988932E+09 | 0.00 | 1.00 | 01-JUN-07:32 | 0.00 | 01-JUN-05:15 | 7603.57 | 06-JUN-07:42 | 5467.27 | 01-JUN-14:02 | 3290.47 | 06-JUN-07:43 | 1694.36 | 01-JUN-14:02 | 0.00 |
| July | 0.511345E+10 | 0.135342E+10 | 725.45 | 0.387515E+10 | 0.123830E+10 | 0.00 | 1.00 | 11-JUL-21:22 | 0.00 | 11-JUL-19:33 | 7523.67 | 12-JUL-06:52 | 6313.50 | 12-JUL-17:42 | 3070.54 | 12-JUL-06:53 | 1615.90 | 15-JUL-06:52 | 0.00 |
| August | 0.484429E+10 | 0.127790E+10 | 703.59 | 0.369320E+10 | 0.115109E+10 | 0.00 | 1.00 | 01-AUG-06:52 | 0.00 | 01-AUG-05:15 | 7691.61 | 29-AUG-08:62 | 6066.47 | 16-AUG-15:52 | 3700.89 | 29-AUG-08:03 | 1626.13 | 27-AUG-07:43 | 0.00 |
| September | 0.406438E+10 | 0.105312E+10 | 630.32 | 0.302644E+10 | 0.103794E+10 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-05:43 | 7804.66 | 05-SEP-08:42 | 6409.72 | 02-SEP-17:12 | 4203.87 | 05-SEP-08:45 | 1612.42 | 01-SEP-07:02 | 0.00 |
| October | 0.327351E+10 | 0.850111E+09 | 542.72 | 0.250661E+10 | 0.766901E+09 | 0.00 | 1.00 | 01-OCT-10:52 | 0.00 | 01-OCT-05:05 | 7747.55 | 21-OCT-08:62 | 6958.70 | 17-OCT-16:12 | 3948.91 | 21-OCT-08:03 | 1623.82 | 10-OCT-09:13 | 0.00 |
| November | 0.984303E+09 | 0.249599E+09 | 235.33 | 0.758564E+09 | 0.225739E+09 | 0.00 | 1.00 | 01-NOV-07:42 | 0.00 | 01-NOV-05:13 | 7717.28 | 29-NOV-11:52 | 6910.73 | 19-NOV-18:12 | 3831.55 | 29-NOV-11:53 | 1628.54 | 29-NOV-12:53 | 0.00 |
| December | 0.625863E+09 | 0.157286E+09 | 148.29 | 0.473014E+09 | 0.152849E+09 | 0.00 | 1.00 | 01-DEC-14:42 | 0.00 | 01-DEC-01:20 | 7711.65 | 12-DEC-11:12 | 6875.31 | 01-DEC-17:12 | 3884.95 | 12-DEC-11:13 | 1603.99 | 09-DEC-10:42 | 0.00 |
| Annual Sum or Average | 0.318683E+11 | 0.832514E+10 | 5214.92 | 0.246175E+11 | 0.725087E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.327756E+09 | 80944555.07 | 91.02 | 0.248788E+09 | 78968249.37 | 0.00 | 1.00 | 0.00 | 7523.67 | 5467.27 | 2968.05 | 1595.66 | 0.00 | ||||||
| Maximum of Months | 0.511345E+10 | 0.135342E+10 | 725.45 | 0.387515E+10 | 0.123830E+10 | 0.00 | 1.00 | 0.00 | 7804.66 | 7014.33 | 4203.87 | 1694.36 | 0.00 |
Report: DXReportMonthly
For: SPLIT TSE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.805906E+09 | 0.198601E+09 | 215.43 | 0.691785E+09 | 0.114121E+09 | 0.00 | 1.00 | 01-JAN-10:52 | 0.00 | 01-JAN-04:30 | 7034.27 | 31-JAN-11:02 | 6585.92 | 29-JAN-15:42 | 2831.39 | 31-JAN-11:03 | 1484.11 | 19-JAN-11:15 | 0.00 |
| February | 0.102515E+10 | 0.251036E+09 | 226.40 | 0.868041E+09 | 0.157106E+09 | 0.00 | 1.00 | 01-FEB-13:22 | 0.00 | 01-FEB-06:03 | 7007.15 | 02-FEB-22:52 | 6531.30 | 08-FEB-13:32 | 2646.80 | 02-FEB-22:53 | 1508.70 | 01-FEB-14:42 | 0.00 |
| March | 0.128460E+10 | 0.319343E+09 | 263.50 | 0.108309E+10 | 0.201503E+09 | 0.00 | 1.00 | 02-MAR-19:02 | 0.00 | 01-MAR-07:00 | 7106.74 | 18-MAR-09:32 | 6582.35 | 16-MAR-16:12 | 3159.04 | 18-MAR-09:33 | 1510.82 | 27-MAR-11:02 | 0.00 |
| April | 0.222841E+10 | 0.564501E+09 | 405.89 | 0.186858E+10 | 0.359831E+09 | 0.00 | 1.00 | 01-APR-11:02 | 0.00 | 01-APR-05:15 | 7129.60 | 30-APR-11:02 | 6587.25 | 16-APR-11:42 | 3194.35 | 30-APR-11:03 | 1536.08 | 24-APR-11:52 | 0.00 |
| May | 0.459698E+10 | 0.120477E+10 | 696.27 | 0.362185E+10 | 0.975130E+09 | 0.00 | 1.00 | 02-MAY-07:52 | 0.00 | 02-MAY-05:15 | 7125.39 | 23-MAY-06:52 | 5569.54 | 13-MAY-12:52 | 3195.11 | 23-MAY-06:53 | 1508.84 | 16-MAY-06:53 | 0.00 |
| June | 0.472680E+10 | 0.125154E+10 | 694.31 | 0.374179E+10 | 0.985011E+09 | 0.00 | 1.00 | 01-JUN-07:32 | 0.00 | 01-JUN-05:15 | 7077.22 | 06-JUN-07:42 | 5236.92 | 01-JUN-14:02 | 2967.06 | 06-JUN-07:43 | 1578.47 | 01-JUN-14:02 | 0.00 |
| July | 0.518970E+10 | 0.136880E+10 | 724.79 | 0.394579E+10 | 0.124392E+10 | 0.00 | 1.00 | 11-JUL-21:22 | 0.00 | 11-JUL-19:33 | 7032.06 | 12-JUL-06:52 | 5870.81 | 12-JUL-15:12 | 2874.85 | 12-JUL-06:53 | 1508.84 | 15-JUL-06:53 | 0.00 |
| August | 0.502430E+10 | 0.131985E+10 | 704.78 | 0.386513E+10 | 0.115916E+10 | 0.00 | 1.00 | 01-AUG-06:52 | 0.00 | 01-AUG-05:15 | 7177.77 | 29-AUG-08:62 | 5709.09 | 16-AUG-15:52 | 3460.76 | 29-AUG-08:05 | 1518.42 | 27-AUG-07:43 | 0.00 |
| September | 0.445064E+10 | 0.114700E+10 | 632.47 | 0.338519E+10 | 0.106546E+10 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-05:43 | 7263.39 | 05-SEP-08:42 | 5894.13 | 02-SEP-16:42 | 3824.30 | 05-SEP-08:45 | 1505.56 | 01-SEP-07:03 | 0.00 |
| October | 0.405065E+10 | 0.103991E+10 | 574.40 | 0.322608E+10 | 0.824573E+09 | 0.00 | 1.00 | 01-OCT-09:52 | 0.00 | 01-OCT-05:15 | 7200.74 | 21-OCT-07:42 | 6533.01 | 29-OCT-14:12 | 3534.96 | 21-OCT-07:45 | 1514.58 | 12-OCT-09:02 | 0.00 |
| November | 0.182137E+10 | 0.453669E+09 | 348.69 | 0.154529E+10 | 0.276083E+09 | 0.00 | 1.00 | 01-NOV-07:32 | 0.00 | 01-NOV-05:13 | 7160.64 | 29-NOV-11:52 | 6626.54 | 18-NOV-12:22 | 3356.18 | 29-NOV-11:55 | 1521.17 | 29-NOV-12:53 | 0.00 |
| December | 0.122886E+10 | 0.304627E+09 | 246.97 | 0.103671E+10 | 0.192150E+09 | 0.00 | 1.00 | 01-DEC-11:32 | 0.00 | 01-DEC-02:00 | 7178.25 | 13-DEC-10:52 | 6599.32 | 31-DEC-15:22 | 3611.90 | 12-DEC-10:23 | 1498.28 | 14-DEC-11:45 | 0.00 |
| Annual Sum or Average | 0.364334E+11 | 0.942364E+10 | 5733.87 | 0.288793E+11 | 0.755405E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.805906E+09 | 0.198601E+09 | 215.43 | 0.691785E+09 | 0.114121E+09 | 0.00 | 1.00 | 0.00 | 7007.15 | 5236.92 | 2646.80 | 1484.11 | 0.00 | ||||||
| Maximum of Months | 0.518970E+10 | 0.136880E+10 | 724.79 | 0.394579E+10 | 0.124392E+10 | 0.00 | 1.00 | 0.00 | 7263.39 | 6626.54 | 3824.30 | 1578.47 | 0.00 |
Report: DXReportMonthly
For: SPLIT TNE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.299631E+09 | 73822650.65 | 86.56 | 0.225063E+09 | 74567584.79 | 0.00 | 1.00 | 01-JAN-12:42 | 0.00 | 01-JAN-02:70 | 6837.59 | 19-JAN-11:02 | 5826.08 | 02-JAN-22:12 | 2759.42 | 19-JAN-22:53 | 1441.09 | 19-JAN-11:23 | 0.00 |
| February | 0.470611E+09 | 0.116307E+09 | 135.27 | 0.362767E+09 | 0.107844E+09 | 0.00 | 1.00 | 01-FEB-14:12 | 0.00 | 01-FEB-06:03 | 6797.40 | 02-FEB-22:52 | 5539.90 | 26-FEB-19:02 | 2697.48 | 02-FEB-22:53 | 1458.24 | 21-FEB-13:52 | 0.00 |
| March | 0.918296E+09 | 0.229575E+09 | 217.19 | 0.734130E+09 | 0.184167E+09 | 0.00 | 1.00 | 04-MAR-12:22 | 0.00 | 01-MAR-06:00 | 6840.72 | 18-MAR-09:42 | 6291.33 | 24-MAR-13:42 | 2917.56 | 18-MAR-09:43 | 1449.96 | 26-MAR-10:02 | 0.00 |
| April | 0.194179E+10 | 0.493669E+09 | 389.05 | 0.159548E+10 | 0.346316E+09 | 0.00 | 1.00 | 01-APR-11:52 | 0.00 | 01-APR-05:15 | 6870.95 | 30-APR-11:52 | 6315.26 | 16-APR-14:52 | 2969.77 | 30-APR-11:53 | 1485.47 | 24-APR-11:52 | 0.00 |
| May | 0.457673E+10 | 0.119700E+10 | 697.04 | 0.359823E+10 | 0.978505E+09 | 0.00 | 1.00 | 02-MAY-07:52 | 0.00 | 02-MAY-05:15 | 6884.74 | 23-MAY-06:52 | 5395.88 | 13-MAY-12:52 | 3055.85 | 23-MAY-06:53 | 1459.03 | 16-MAY-06:53 | 0.00 |
| June | 0.480768E+10 | 0.126949E+10 | 694.83 | 0.381197E+10 | 0.995709E+09 | 0.00 | 1.00 | 01-JUN-07:32 | 0.00 | 01-JUN-05:15 | 6861.62 | 06-JUN-07:42 | 5071.86 | 01-JUN-14:02 | 2946.94 | 06-JUN-07:43 | 1525.95 | 01-JUN-14:02 | 0.00 |
| July | 0.521150E+10 | 0.137161E+10 | 725.04 | 0.396502E+10 | 0.124648E+10 | 0.00 | 1.00 | 11-JUL-21:22 | 0.00 | 11-JUL-19:33 | 6798.39 | 12-JUL-06:52 | 5625.56 | 12-JUL-15:22 | 2756.83 | 12-JUL-06:53 | 1459.02 | 15-JUL-06:53 | 0.00 |
| August | 0.486160E+10 | 0.127574E+10 | 704.81 | 0.370707E+10 | 0.115453E+10 | 0.00 | 1.00 | 01-AUG-06:52 | 0.00 | 01-AUG-05:15 | 6928.37 | 29-AUG-08:62 | 5436.35 | 16-AUG-15:52 | 3294.23 | 29-AUG-08:05 | 1468.38 | 27-AUG-07:43 | 0.00 |
| September | 0.406272E+10 | 0.104755E+10 | 630.81 | 0.302275E+10 | 0.103997E+10 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-05:43 | 7041.49 | 05-SEP-08:42 | 5588.14 | 02-SEP-17:12 | 3770.54 | 05-SEP-08:45 | 1455.86 | 01-SEP-07:03 | 0.00 |
| October | 0.324298E+10 | 0.837639E+09 | 540.17 | 0.247416E+10 | 0.768825E+09 | 0.00 | 1.00 | 01-OCT-10:52 | 0.00 | 01-OCT-05:05 | 6984.79 | 21-OCT-08:62 | 6224.11 | 17-OCT-16:32 | 3534.90 | 20-OCT-08:23 | 1466.16 | 10-OCT-09:12 | 0.00 |
| November | 0.959240E+09 | 0.242173E+09 | 233.47 | 0.734445E+09 | 0.224796E+09 | 0.00 | 1.00 | 01-NOV-07:42 | 0.00 | 01-NOV-05:13 | 6952.88 | 29-NOV-11:52 | 6232.56 | 19-NOV-16:32 | 3386.40 | 29-NOV-11:55 | 1470.55 | 29-NOV-12:53 | 0.00 |
| December | 0.580234E+09 | 0.145174E+09 | 144.20 | 0.431441E+09 | 0.148792E+09 | 0.00 | 1.00 | 01-DEC-14:42 | 0.00 | 01-DEC-00:30 | 6965.93 | 12-DEC-11:12 | 6216.38 | 01-DEC-17:12 | 3483.54 | 12-DEC-11:13 | 1448.47 | 09-DEC-10:42 | 0.00 |
| Annual Sum or Average | 0.319330E+11 | 0.829975E+10 | 5198.44 | 0.246625E+11 | 0.727050E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.299631E+09 | 73822650.65 | 86.56 | 0.225063E+09 | 74567584.79 | 0.00 | 1.00 | 0.00 | 6797.40 | 5071.86 | 2697.48 | 1441.09 | 0.00 | ||||||
| Maximum of Months | 0.521150E+10 | 0.137161E+10 | 725.04 | 0.396502E+10 | 0.124648E+10 | 0.00 | 1.00 | 0.00 | 7041.49 | 6315.26 | 3770.54 | 1525.95 | 0.00 |
Report: DXReportMonthly
For: SPLIT TN1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.306872E+09 | 75736537.97 | 107.29 | 0.229125E+09 | 77746741.65 | 0.00 | 1.00 | 01-JAN-12:42 | 0.00 | 01-JAN-05:00 | 6353.28 | 31-JAN-11:22 | 5483.11 | 02-JAN-22:12 | 2529.70 | 19-JAN-22:53 | 1342.74 | 19-JAN-11:23 | 0.00 |
| February | 0.471683E+09 | 0.116984E+09 | 159.71 | 0.359090E+09 | 0.112593E+09 | 0.00 | 1.00 | 01-FEB-14:12 | 0.00 | 01-FEB-06:03 | 6329.43 | 02-FEB-22:52 | 5153.48 | 25-FEB-19:42 | 2441.31 | 02-FEB-22:53 | 1359.34 | 21-FEB-13:52 | 0.00 |
| March | 0.825793E+09 | 0.207014E+09 | 240.40 | 0.649929E+09 | 0.175864E+09 | 0.00 | 1.00 | 04-MAR-12:22 | 0.00 | 01-MAR-07:00 | 6369.58 | 18-MAR-09:42 | 5777.50 | 04-MAR-22:52 | 2721.87 | 18-MAR-09:43 | 1351.68 | 26-MAR-10:02 | 0.00 |
| April | 0.170825E+10 | 0.435195E+09 | 403.72 | 0.138237E+10 | 0.325877E+09 | 0.00 | 1.00 | 01-APR-11:52 | 0.00 | 01-APR-05:15 | 6422.34 | 24-APR-10:42 | 5828.11 | 16-APR-14:52 | 2887.09 | 24-APR-10:45 | 1384.47 | 24-APR-11:53 | 0.00 |
| May | 0.386849E+10 | 0.101421E+10 | 692.79 | 0.298636E+10 | 0.882138E+09 | 0.00 | 1.00 | 02-MAY-07:52 | 0.00 | 02-MAY-05:15 | 6402.03 | 23-MAY-06:52 | 4908.56 | 13-MAY-12:52 | 2788.41 | 23-MAY-06:53 | 1359.84 | 16-MAY-06:53 | 0.00 |
| June | 0.406700E+10 | 0.107653E+10 | 694.44 | 0.315420E+10 | 0.912798E+09 | 0.00 | 1.00 | 01-JUN-07:32 | 0.00 | 01-JUN-05:15 | 6383.96 | 06-JUN-07:42 | 4591.56 | 01-JUN-14:02 | 2694.65 | 06-JUN-07:43 | 1426.09 | 01-JUN-14:02 | 0.00 |
| July | 0.442065E+10 | 0.116583E+10 | 725.11 | 0.328545E+10 | 0.113520E+10 | 0.00 | 1.00 | 11-JUL-21:22 | 0.00 | 11-JUL-19:33 | 6326.56 | 12-JUL-06:52 | 5040.35 | 12-JUL-15:22 | 2535.44 | 12-JUL-06:53 | 1359.83 | 15-JUL-06:52 | 0.00 |
| August | 0.414834E+10 | 0.109062E+10 | 703.87 | 0.310407E+10 | 0.104427E+10 | 0.00 | 1.00 | 01-AUG-06:52 | 0.00 | 01-AUG-05:15 | 6460.64 | 29-AUG-08:62 | 4844.06 | 16-AUG-15:52 | 3087.26 | 29-AUG-08:05 | 1368.59 | 27-AUG-07:43 | 0.00 |
| September | 0.352473E+10 | 0.909406E+09 | 630.33 | 0.257894E+10 | 0.945784E+09 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-05:43 | 6555.09 | 05-SEP-08:42 | 5064.36 | 02-SEP-17:12 | 3481.22 | 05-SEP-08:45 | 1356.89 | 05-SEP-08:55 | 0.00 |
| October | 0.281174E+10 | 0.727583E+09 | 555.12 | 0.211738E+10 | 0.694362E+09 | 0.00 | 1.00 | 01-OCT-10:52 | 0.00 | 01-OCT-05:15 | 6507.01 | 21-OCT-08:62 | 5798.51 | 17-OCT-16:32 | 3278.23 | 21-OCT-08:05 | 1366.48 | 10-OCT-09:13 | 0.00 |
| November | 0.904089E+09 | 0.228212E+09 | 257.71 | 0.686067E+09 | 0.218022E+09 | 0.00 | 1.00 | 01-NOV-07:42 | 0.00 | 01-NOV-05:13 | 6480.69 | 29-NOV-11:52 | 5816.43 | 19-NOV-18:12 | 3154.80 | 29-NOV-11:55 | 1370.52 | 29-NOV-12:53 | 0.00 |
| December | 0.567848E+09 | 0.141911E+09 | 156.24 | 0.420181E+09 | 0.147667E+09 | 0.00 | 1.00 | 01-DEC-14:42 | 0.00 | 01-DEC-02:70 | 6491.98 | 12-DEC-11:12 | 5787.55 | 01-DEC-17:12 | 3222.74 | 12-DEC-11:15 | 1349.80 | 09-DEC-10:42 | 0.00 |
| Annual Sum or Average | 0.276255E+11 | 0.718923E+10 | 5326.74 | 0.209532E+11 | 0.667232E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.306872E+09 | 75736537.97 | 107.29 | 0.229125E+09 | 77746741.65 | 0.00 | 1.00 | 0.00 | 6326.56 | 4591.56 | 2441.31 | 1342.74 | 0.00 | ||||||
| Maximum of Months | 0.442065E+10 | 0.116583E+10 | 725.11 | 0.328545E+10 | 0.113520E+10 | 0.00 | 1.00 | 0.00 | 6555.09 | 5828.11 | 3481.22 | 1426.09 | 0.00 |
Report: DXReportMonthly
For: SPLIT TN2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.305488E+09 | 75385420.01 | 106.61 | 0.227978E+09 | 77510063.89 | 0.00 | 1.00 | 01-JAN-12:42 | 0.00 | 01-JAN-05:00 | 6330.56 | 19-JAN-22:52 | 5458.83 | 02-JAN-22:12 | 2535.67 | 19-JAN-22:53 | 1337.74 | 19-JAN-11:23 | 0.00 |
| February | 0.469909E+09 | 0.116530E+09 | 159.70 | 0.357686E+09 | 0.112223E+09 | 0.00 | 1.00 | 01-FEB-14:12 | 0.00 | 01-FEB-06:03 | 6306.19 | 02-FEB-22:52 | 5125.91 | 25-FEB-19:42 | 2434.28 | 02-FEB-22:53 | 1354.28 | 21-FEB-13:52 | 0.00 |
| March | 0.829067E+09 | 0.207806E+09 | 240.76 | 0.652762E+09 | 0.176305E+09 | 0.00 | 1.00 | 04-MAR-12:22 | 0.00 | 01-MAR-07:00 | 6345.86 | 18-MAR-09:42 | 5753.56 | 04-MAR-22:52 | 2713.06 | 18-MAR-09:43 | 1346.69 | 26-MAR-10:02 | 0.00 |
| April | 0.171067E+10 | 0.435751E+09 | 404.17 | 0.138456E+10 | 0.326112E+09 | 0.00 | 1.00 | 01-APR-11:52 | 0.00 | 01-APR-05:15 | 6397.91 | 24-APR-10:42 | 5811.71 | 16-APR-14:52 | 2873.70 | 24-APR-10:45 | 1379.32 | 24-APR-11:53 | 0.00 |
| May | 0.387322E+10 | 0.101528E+10 | 693.13 | 0.299032E+10 | 0.882898E+09 | 0.00 | 1.00 | 02-MAY-07:52 | 0.00 | 02-MAY-05:15 | 6378.23 | 23-MAY-06:52 | 4894.36 | 13-MAY-12:52 | 2778.02 | 23-MAY-06:53 | 1354.78 | 16-MAY-06:53 | 0.00 |
| June | 0.407025E+10 | 0.107721E+10 | 694.42 | 0.315691E+10 | 0.913337E+09 | 0.00 | 1.00 | 01-JUN-07:32 | 0.00 | 01-JUN-05:15 | 6360.35 | 06-JUN-07:42 | 4577.60 | 01-JUN-14:02 | 2685.82 | 06-JUN-07:43 | 1420.68 | 01-JUN-14:02 | 0.00 |
| July | 0.442492E+10 | 0.116678E+10 | 725.17 | 0.328914E+10 | 0.113578E+10 | 0.00 | 1.00 | 11-JUL-21:22 | 0.00 | 11-JUL-19:33 | 6303.08 | 12-JUL-06:52 | 5024.16 | 12-JUL-15:22 | 2526.63 | 12-JUL-06:53 | 1354.78 | 15-JUL-06:52 | 0.00 |
| August | 0.414961E+10 | 0.109080E+10 | 703.83 | 0.310499E+10 | 0.104463E+10 | 0.00 | 1.00 | 01-AUG-06:52 | 0.00 | 01-AUG-05:15 | 6436.14 | 29-AUG-08:62 | 4826.18 | 16-AUG-15:52 | 3073.89 | 29-AUG-08:05 | 1363.50 | 27-AUG-07:43 | 0.00 |
| September | 0.352544E+10 | 0.909462E+09 | 630.36 | 0.257932E+10 | 0.946124E+09 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-05:43 | 6530.53 | 05-SEP-08:42 | 5041.00 | 02-SEP-17:12 | 3467.84 | 05-SEP-08:45 | 1351.84 | 05-SEP-08:55 | 0.00 |
| October | 0.281152E+10 | 0.727424E+09 | 554.08 | 0.211697E+10 | 0.694547E+09 | 0.00 | 1.00 | 01-OCT-10:52 | 0.00 | 01-OCT-05:15 | 6483.06 | 21-OCT-08:62 | 5776.88 | 17-OCT-16:32 | 3265.16 | 21-OCT-08:05 | 1361.40 | 10-OCT-09:13 | 0.00 |
| November | 0.904858E+09 | 0.228361E+09 | 256.71 | 0.686672E+09 | 0.218186E+09 | 0.00 | 1.00 | 01-NOV-07:42 | 0.00 | 01-NOV-05:13 | 6456.30 | 29-NOV-11:52 | 5788.57 | 19-NOV-18:12 | 3142.04 | 29-NOV-11:55 | 1365.81 | 29-NOV-12:55 | 0.00 |
| December | 0.566082E+09 | 0.141445E+09 | 155.25 | 0.418599E+09 | 0.147483E+09 | 0.00 | 1.00 | 01-DEC-14:42 | 0.00 | 01-DEC-02:70 | 6467.83 | 12-DEC-11:12 | 5759.60 | 01-DEC-17:12 | 3211.17 | 12-DEC-11:15 | 1344.81 | 09-DEC-10:42 | 0.00 |
| Annual Sum or Average | 0.276410E+11 | 0.719223E+10 | 5324.18 | 0.209659E+11 | 0.667514E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.305488E+09 | 75385420.01 | 106.61 | 0.227978E+09 | 77510063.89 | 0.00 | 1.00 | 0.00 | 6303.08 | 4577.60 | 2434.28 | 1337.74 | 0.00 | ||||||
| Maximum of Months | 0.442492E+10 | 0.116678E+10 | 725.17 | 0.328914E+10 | 0.113578E+10 | 0.00 | 1.00 | 0.00 | 6530.53 | 5811.71 | 3467.84 | 1420.68 | 0.00 |
Report: DXReportMonthly
For: SPLIT TS1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.877961E+09 | 0.217670E+09 | 258.33 | 0.759814E+09 | 0.118146E+09 | 0.00 | 1.00 | 01-JAN-10:52 | 0.00 | 01-JAN-06:03 | 6592.37 | 31-JAN-11:02 | 6130.79 | 15-JAN-16:42 | 2626.31 | 31-JAN-11:03 | 1389.07 | 17-JAN-13:12 | 0.00 |
| February | 0.105993E+10 | 0.260968E+09 | 271.06 | 0.896662E+09 | 0.163273E+09 | 0.00 | 1.00 | 01-FEB-13:22 | 0.00 | 01-FEB-06:03 | 6537.21 | 02-FEB-22:52 | 6108.27 | 08-FEB-13:32 | 2333.27 | 02-FEB-22:53 | 1414.14 | 01-FEB-14:42 | 0.00 |
| March | 0.121016E+10 | 0.302347E+09 | 304.58 | 0.101424E+10 | 0.195923E+09 | 0.00 | 1.00 | 02-MAR-19:02 | 0.00 | 01-MAR-07:00 | 6659.02 | 18-MAR-09:32 | 6137.68 | 15-MAR-16:32 | 2966.00 | 18-MAR-09:33 | 1416.28 | 27-MAR-11:02 | 0.00 |
| April | 0.199756E+10 | 0.507579E+09 | 425.50 | 0.165657E+10 | 0.340992E+09 | 0.00 | 1.00 | 01-APR-11:22 | 0.00 | 01-APR-05:15 | 6680.96 | 30-APR-11:02 | 6104.49 | 16-APR-13:12 | 2966.32 | 30-APR-11:03 | 1440.09 | 24-APR-11:52 | 0.00 |
| May | 0.388853E+10 | 0.102179E+10 | 690.63 | 0.300999E+10 | 0.878535E+09 | 0.00 | 1.00 | 02-MAY-07:52 | 0.00 | 02-MAY-05:15 | 6664.71 | 23-MAY-06:52 | 5093.13 | 13-MAY-12:52 | 2934.47 | 23-MAY-06:53 | 1414.47 | 16-MAY-06:53 | 0.00 |
| June | 0.398377E+10 | 0.105732E+10 | 691.89 | 0.308325E+10 | 0.900516E+09 | 0.00 | 1.00 | 01-JUN-07:32 | 0.00 | 01-JUN-05:15 | 6629.05 | 06-JUN-07:42 | 4796.92 | 01-JUN-14:02 | 2754.19 | 06-JUN-07:43 | 1482.92 | 01-JUN-14:02 | 0.00 |
| July | 0.439787E+10 | 0.116237E+10 | 724.95 | 0.326594E+10 | 0.113193E+10 | 0.00 | 1.00 | 11-JUL-21:22 | 0.00 | 11-JUL-19:33 | 6582.24 | 12-JUL-06:52 | 5289.59 | 12-JUL-15:12 | 2660.35 | 12-JUL-06:53 | 1414.47 | 15-JUL-06:52 | 0.00 |
| August | 0.431389E+10 | 0.113590E+10 | 703.47 | 0.326330E+10 | 0.105059E+10 | 0.00 | 1.00 | 01-AUG-06:52 | 0.00 | 01-AUG-05:15 | 6731.93 | 29-AUG-08:62 | 5205.71 | 16-AUG-15:52 | 3270.92 | 29-AUG-08:05 | 1423.50 | 27-AUG-07:43 | 0.00 |
| September | 0.391938E+10 | 0.101184E+10 | 632.15 | 0.294526E+10 | 0.974120E+09 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-05:43 | 6798.69 | 05-SEP-08:42 | 5246.79 | 02-SEP-17:52 | 3540.54 | 05-SEP-08:45 | 1411.40 | 01-SEP-07:02 | 0.00 |
| October | 0.363401E+10 | 0.935602E+09 | 591.91 | 0.288210E+10 | 0.751913E+09 | 0.00 | 1.00 | 01-OCT-09:52 | 0.00 | 01-OCT-05:15 | 6735.14 | 21-OCT-07:42 | 6134.88 | 29-OCT-14:12 | 3254.38 | 20-OCT-08:25 | 1419.83 | 12-OCT-09:02 | 0.00 |
| November | 0.181420E+10 | 0.452880E+09 | 395.85 | 0.154098E+10 | 0.273221E+09 | 0.00 | 1.00 | 01-NOV-07:32 | 0.00 | 01-NOV-05:13 | 6710.33 | 29-NOV-11:52 | 6179.18 | 21-NOV-12:22 | 3125.56 | 29-NOV-11:55 | 1426.02 | 29-NOV-12:53 | 0.00 |
| December | 0.129379E+10 | 0.321649E+09 | 296.87 | 0.109991E+10 | 0.193884E+09 | 0.00 | 1.00 | 01-DEC-11:32 | 0.00 | 01-DEC-04:10 | 6724.66 | 13-DEC-10:52 | 6177.12 | 31-DEC-15:22 | 3324.08 | 12-DEC-10:23 | 1404.55 | 14-DEC-11:45 | 0.00 |
| Annual Sum or Average | 0.323911E+11 | 0.838792E+10 | 5987.18 | 0.254180E+11 | 0.697305E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.877961E+09 | 0.217670E+09 | 258.33 | 0.759814E+09 | 0.118146E+09 | 0.00 | 1.00 | 0.00 | 6537.21 | 4796.92 | 2333.27 | 1389.07 | 0.00 | ||||||
| Maximum of Months | 0.439787E+10 | 0.116237E+10 | 724.95 | 0.326594E+10 | 0.113193E+10 | 0.00 | 1.00 | 0.00 | 6798.69 | 6179.18 | 3540.54 | 1482.92 | 0.00 |
Report: DXReportMonthly
For: SPLIT TS2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.880694E+09 | 0.218315E+09 | 259.22 | 0.762505E+09 | 0.118189E+09 | 0.00 | 1.00 | 01-JAN-10:52 | 0.00 | 01-JAN-06:03 | 6568.91 | 31-JAN-11:02 | 6111.56 | 15-JAN-14:23 | 2617.80 | 31-JAN-11:03 | 1387.03 | 19-JAN-11:15 | 0.00 |
| February | 0.106038E+10 | 0.261033E+09 | 270.24 | 0.897174E+09 | 0.163209E+09 | 0.00 | 1.00 | 01-FEB-13:22 | 0.00 | 01-FEB-06:03 | 6514.14 | 02-FEB-22:52 | 6088.29 | 08-FEB-13:32 | 2326.65 | 02-FEB-22:53 | 1409.11 | 01-FEB-14:42 | 0.00 |
| March | 0.121575E+10 | 0.303631E+09 | 305.62 | 0.101876E+10 | 0.196996E+09 | 0.00 | 1.00 | 02-MAR-19:02 | 0.00 | 01-MAR-07:00 | 6635.24 | 18-MAR-09:32 | 6116.02 | 15-MAR-16:32 | 2956.50 | 18-MAR-09:33 | 1411.24 | 27-MAR-11:02 | 0.00 |
| April | 0.200056E+10 | 0.508228E+09 | 425.38 | 0.165934E+10 | 0.341220E+09 | 0.00 | 1.00 | 01-APR-11:22 | 0.00 | 01-APR-05:15 | 6657.28 | 30-APR-11:02 | 6085.65 | 16-APR-13:12 | 2956.93 | 30-APR-11:03 | 1434.96 | 24-APR-11:52 | 0.00 |
| May | 0.389332E+10 | 0.102289E+10 | 690.66 | 0.301403E+10 | 0.879287E+09 | 0.00 | 1.00 | 02-MAY-07:52 | 0.00 | 02-MAY-05:15 | 6640.97 | 23-MAY-06:52 | 5079.42 | 13-MAY-12:52 | 2923.98 | 23-MAY-06:53 | 1409.43 | 16-MAY-06:53 | 0.00 |
| June | 0.398717E+10 | 0.105807E+10 | 692.08 | 0.308609E+10 | 0.901074E+09 | 0.00 | 1.00 | 01-JUN-07:32 | 0.00 | 01-JUN-05:15 | 6605.58 | 06-JUN-07:42 | 4783.31 | 01-JUN-14:02 | 2745.65 | 06-JUN-07:43 | 1477.52 | 01-JUN-14:02 | 0.00 |
| July | 0.440224E+10 | 0.116336E+10 | 724.95 | 0.326967E+10 | 0.113257E+10 | 0.00 | 1.00 | 11-JUL-21:22 | 0.00 | 11-JUL-19:33 | 6558.83 | 12-JUL-06:52 | 5273.74 | 12-JUL-15:12 | 2651.39 | 12-JUL-06:53 | 1409.43 | 15-JUL-06:52 | 0.00 |
| August | 0.431520E+10 | 0.113606E+10 | 703.39 | 0.326405E+10 | 0.105116E+10 | 0.00 | 1.00 | 01-AUG-06:52 | 0.00 | 01-AUG-05:15 | 6708.28 | 29-AUG-08:62 | 5185.60 | 16-AUG-15:52 | 3257.10 | 29-AUG-08:05 | 1418.43 | 27-AUG-07:43 | 0.00 |
| September | 0.391996E+10 | 0.101183E+10 | 632.00 | 0.294556E+10 | 0.974400E+09 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-05:43 | 6774.28 | 05-SEP-08:42 | 5220.77 | 02-SEP-17:52 | 3527.48 | 05-SEP-08:45 | 1406.37 | 01-SEP-07:02 | 0.00 |
| October | 0.363425E+10 | 0.935474E+09 | 591.31 | 0.288201E+10 | 0.752238E+09 | 0.00 | 1.00 | 01-OCT-09:52 | 0.00 | 01-OCT-05:15 | 6711.03 | 21-OCT-07:42 | 6110.60 | 29-OCT-14:12 | 3243.84 | 20-OCT-08:25 | 1414.78 | 12-OCT-09:02 | 0.00 |
| November | 0.181649E+10 | 0.453336E+09 | 396.18 | 0.154307E+10 | 0.273419E+09 | 0.00 | 1.00 | 01-NOV-07:32 | 0.00 | 01-NOV-05:13 | 6686.09 | 29-NOV-11:52 | 6157.97 | 21-NOV-12:22 | 3112.80 | 29-NOV-11:55 | 1420.94 | 29-NOV-12:53 | 0.00 |
| December | 0.129208E+10 | 0.321156E+09 | 295.76 | 0.109828E+10 | 0.193805E+09 | 0.00 | 1.00 | 01-DEC-11:32 | 0.00 | 01-DEC-04:00 | 6700.64 | 13-DEC-10:52 | 6156.61 | 31-DEC-15:22 | 3312.85 | 12-DEC-10:23 | 1399.55 | 14-DEC-11:45 | 0.00 |
| Annual Sum or Average | 0.324181E+11 | 0.839339E+10 | 5986.79 | 0.254405E+11 | 0.697757E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.880694E+09 | 0.218315E+09 | 259.22 | 0.762505E+09 | 0.118189E+09 | 0.00 | 1.00 | 0.00 | 6514.14 | 4783.31 | 2326.65 | 1387.03 | 0.00 | ||||||
| Maximum of Months | 0.440224E+10 | 0.116336E+10 | 724.95 | 0.326967E+10 | 0.113257E+10 | 0.00 | 1.00 | 0.00 | 6774.28 | 6157.97 | 3527.48 | 1477.52 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 187.72 | 133.34 | 54.38 | 271.70 | 131.24 | 0.00 | 0.00 | 0.00 |
| February | 173.17 | 112.51 | 60.65 | 256.77 | 110.68 | 0.00 | 0.00 | 0.00 |
| March | 108.35 | 48.13 | 60.23 | 165.68 | 96.03 | 0.00 | 0.00 | 0.00 |
| April | 83.19 | 20.88 | 62.31 | 141.48 | 59.85 | 0.00 | 0.00 | 0.00 |
| May | 62.38 | 2.83 | 59.55 | 136.95 | 11.44 | 0.00 | 0.00 | 0.00 |
| June | 61.48 | 0.64 | 60.84 | 138.99 | 9.38 | 0.00 | 0.00 | 0.00 |
| July | 64.33 | 1.21 | 63.12 | 146.09 | 5.22 | 0.00 | 0.00 | 0.00 |
| August | 75.00 | 8.43 | 66.57 | 166.93 | 10.45 | 0.00 | 0.00 | 0.00 |
| September | 91.98 | 25.14 | 66.84 | 187.07 | 17.81 | 0.00 | 0.00 | 0.00 |
| October | 138.27 | 70.82 | 67.46 | 257.26 | 36.57 | 0.00 | 0.00 | 0.00 |
| November | 179.89 | 124.07 | 55.82 | 283.32 | 86.10 | 0.00 | 0.00 | 0.00 |
| December | 184.96 | 132.74 | 52.21 | 278.74 | 116.44 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 117.25 | 56.42 | 60.83 | 202.30 | 57.32 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61.48 | 0.64 | 52.21 | 136.95 | 5.22 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 187.72 | 133.34 | 67.46 | 283.32 | 131.24 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 W SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 59.00 | 31.87 | 27.13 | 72.75 | 95.19 | 0.00 | 0.00 | 0.00 |
| February | 66.76 | 33.75 | 33.02 | 87.24 | 78.64 | 0.00 | 0.00 | 0.00 |
| March | 65.92 | 29.17 | 36.75 | 91.92 | 64.43 | 0.00 | 0.00 | 0.00 |
| April | 81.76 | 37.55 | 44.21 | 131.78 | 38.35 | 0.00 | 0.00 | 0.00 |
| May | 68.11 | 22.17 | 45.95 | 137.49 | 7.56 | 0.00 | 0.00 | 0.00 |
| June | 75.73 | 26.62 | 49.11 | 155.67 | 6.12 | 0.00 | 0.00 | 0.00 |
| July | 69.00 | 19.12 | 49.88 | 143.87 | 3.51 | 0.00 | 0.00 | 0.00 |
| August | 69.77 | 21.27 | 48.49 | 142.79 | 6.79 | 0.00 | 0.00 | 0.00 |
| September | 64.32 | 22.08 | 42.24 | 123.70 | 11.63 | 0.00 | 0.00 | 0.00 |
| October | 65.68 | 28.32 | 37.36 | 119.04 | 24.70 | 0.00 | 0.00 | 0.00 |
| November | 56.39 | 28.33 | 28.06 | 80.35 | 61.59 | 0.00 | 0.00 | 0.00 |
| December | 54.26 | 28.85 | 25.41 | 70.76 | 82.30 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.36 | 27.36 | 39.00 | 113.22 | 39.87 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 54.26 | 19.12 | 25.41 | 70.76 | 3.51 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 81.76 | 37.55 | 49.88 | 155.67 | 95.19 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 W NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 59.00 | 31.87 | 27.13 | 76.63 | 88.33 | 0.00 | 0.00 | 0.00 |
| February | 66.76 | 33.75 | 33.02 | 91.27 | 72.99 | 0.00 | 0.00 | 0.00 |
| March | 65.92 | 29.17 | 36.75 | 94.28 | 61.70 | 0.00 | 0.00 | 0.00 |
| April | 81.76 | 37.55 | 44.21 | 132.74 | 37.76 | 0.00 | 0.00 | 0.00 |
| May | 68.11 | 22.17 | 45.95 | 137.56 | 7.57 | 0.00 | 0.00 | 0.00 |
| June | 75.73 | 26.62 | 49.11 | 155.50 | 6.20 | 0.00 | 0.00 | 0.00 |
| July | 69.00 | 19.12 | 49.88 | 143.78 | 3.53 | 0.00 | 0.00 | 0.00 |
| August | 69.77 | 21.27 | 48.49 | 143.13 | 6.72 | 0.00 | 0.00 | 0.00 |
| September | 64.32 | 22.08 | 42.24 | 124.43 | 11.25 | 0.00 | 0.00 | 0.00 |
| October | 65.68 | 28.32 | 37.36 | 120.52 | 23.78 | 0.00 | 0.00 | 0.00 |
| November | 56.39 | 28.33 | 28.06 | 82.73 | 59.24 | 0.00 | 0.00 | 0.00 |
| December | 54.26 | 28.85 | 25.41 | 73.61 | 77.95 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.36 | 27.36 | 39.00 | 114.77 | 37.90 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 54.26 | 19.12 | 25.41 | 73.61 | 3.53 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 81.76 | 37.55 | 49.88 | 155.50 | 88.33 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 32.80 | 0.00 | 32.80 | 21.47 | 143.17 | 0.00 | 0.00 | 0.00 |
| February | 38.70 | 0.00 | 38.70 | 31.34 | 117.15 | 0.00 | 0.00 | 0.00 |
| March | 44.90 | 0.00 | 44.90 | 47.04 | 97.47 | 0.00 | 0.00 | 0.00 |
| April | 53.12 | 0.31 | 52.81 | 74.73 | 58.34 | 0.00 | 0.00 | 0.00 |
| May | 60.12 | 2.26 | 57.86 | 130.63 | 10.98 | 0.00 | 0.00 | 0.00 |
| June | 68.16 | 4.64 | 63.51 | 153.24 | 8.95 | 0.00 | 0.00 | 0.00 |
| July | 66.19 | 2.47 | 63.72 | 149.12 | 5.30 | 0.00 | 0.00 | 0.00 |
| August | 59.52 | 0.61 | 58.91 | 132.46 | 9.94 | 0.00 | 0.00 | 0.00 |
| September | 51.25 | 0.01 | 51.24 | 104.04 | 17.21 | 0.00 | 0.00 | 0.00 |
| October | 44.52 | 0.00 | 44.52 | 81.94 | 36.87 | 0.00 | 0.00 | 0.00 |
| November | 33.80 | 0.00 | 33.80 | 33.26 | 94.06 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 22.58 | 125.93 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.68 | 0.86 | 47.82 | 82.13 | 60.15 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 21.47 | 5.30 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 68.16 | 4.64 | 63.72 | 153.24 | 143.17 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 187.72 | 133.34 | 54.38 | 271.19 | 134.35 | 0.00 | 0.00 | 0.00 |
| February | 173.17 | 112.51 | 60.65 | 257.52 | 112.99 | 0.00 | 0.00 | 0.00 |
| March | 108.35 | 48.13 | 60.23 | 164.20 | 100.51 | 0.00 | 0.00 | 0.00 |
| April | 83.19 | 20.88 | 62.31 | 137.01 | 69.41 | 0.00 | 0.00 | 0.00 |
| May | 62.38 | 2.83 | 59.55 | 123.09 | 28.24 | 0.00 | 0.00 | 0.00 |
| June | 61.48 | 0.64 | 60.84 | 124.16 | 26.71 | 0.00 | 0.00 | 0.00 |
| July | 64.33 | 1.21 | 63.12 | 125.64 | 22.90 | 0.00 | 0.00 | 0.00 |
| August | 75.00 | 8.43 | 66.57 | 151.07 | 29.70 | 0.00 | 0.00 | 0.00 |
| September | 91.98 | 25.14 | 66.84 | 172.93 | 38.48 | 0.00 | 0.00 | 0.00 |
| October | 138.27 | 70.82 | 67.46 | 246.79 | 56.95 | 0.00 | 0.00 | 0.00 |
| November | 179.89 | 124.07 | 55.82 | 280.12 | 98.17 | 0.00 | 0.00 | 0.00 |
| December | 184.96 | 132.74 | 52.21 | 277.03 | 123.20 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 117.25 | 56.42 | 60.83 | 193.88 | 69.91 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61.48 | 0.64 | 52.21 | 123.09 | 22.90 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 187.72 | 133.34 | 67.46 | 280.12 | 134.35 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 E SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 55.78 | 28.52 | 27.26 | 63.23 | 93.80 | 0.00 | 0.00 | 0.00 |
| February | 61.71 | 29.68 | 32.03 | 76.29 | 76.94 | 0.00 | 0.00 | 0.00 |
| March | 72.77 | 35.05 | 37.73 | 99.49 | 64.43 | 0.00 | 0.00 | 0.00 |
| April | 80.05 | 36.26 | 43.79 | 124.17 | 43.25 | 0.00 | 0.00 | 0.00 |
| May | 82.35 | 35.73 | 46.61 | 151.86 | 17.72 | 0.00 | 0.00 | 0.00 |
| June | 83.47 | 33.12 | 50.36 | 158.80 | 16.66 | 0.00 | 0.00 | 0.00 |
| July | 80.54 | 29.51 | 51.02 | 150.78 | 14.54 | 0.00 | 0.00 | 0.00 |
| August | 74.18 | 25.48 | 48.70 | 138.47 | 18.69 | 0.00 | 0.00 | 0.00 |
| September | 65.61 | 22.51 | 43.10 | 115.50 | 24.71 | 0.00 | 0.00 | 0.00 |
| October | 65.07 | 27.53 | 37.53 | 108.80 | 37.45 | 0.00 | 0.00 | 0.00 |
| November | 57.48 | 29.31 | 28.17 | 76.18 | 66.85 | 0.00 | 0.00 | 0.00 |
| December | 45.29 | 20.54 | 24.75 | 52.23 | 85.89 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 68.72 | 29.43 | 39.29 | 109.82 | 46.59 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 45.29 | 20.54 | 24.75 | 52.23 | 14.54 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 83.47 | 36.26 | 51.02 | 158.80 | 93.80 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 E NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 55.78 | 28.52 | 27.26 | 66.82 | 84.40 | 0.00 | 0.00 | 0.00 |
| February | 61.71 | 29.68 | 32.03 | 79.26 | 69.41 | 0.00 | 0.00 | 0.00 |
| March | 72.77 | 35.05 | 37.73 | 102.15 | 58.62 | 0.00 | 0.00 | 0.00 |
| April | 80.05 | 36.26 | 43.79 | 127.69 | 36.28 | 0.00 | 0.00 | 0.00 |
| May | 82.35 | 35.73 | 46.61 | 161.39 | 7.07 | 0.00 | 0.00 | 0.00 |
| June | 83.47 | 33.12 | 50.36 | 168.86 | 5.75 | 0.00 | 0.00 | 0.00 |
| July | 80.54 | 29.51 | 51.02 | 164.32 | 3.32 | 0.00 | 0.00 | 0.00 |
| August | 74.18 | 25.48 | 48.70 | 149.68 | 6.31 | 0.00 | 0.00 | 0.00 |
| September | 65.61 | 22.51 | 43.10 | 125.77 | 10.79 | 0.00 | 0.00 | 0.00 |
| October | 65.07 | 27.53 | 37.53 | 117.05 | 22.54 | 0.00 | 0.00 | 0.00 |
| November | 57.48 | 29.31 | 28.17 | 79.97 | 55.83 | 0.00 | 0.00 | 0.00 |
| December | 45.29 | 20.54 | 24.75 | 55.64 | 76.02 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 68.72 | 29.43 | 39.29 | 116.76 | 36.19 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 45.29 | 20.54 | 24.75 | 55.64 | 3.32 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 83.47 | 36.26 | 51.02 | 168.86 | 84.40 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 32.80 | 0.00 | 32.80 | 21.09 | 142.86 | 0.00 | 0.00 | 0.00 |
| February | 38.70 | 0.00 | 38.70 | 30.88 | 116.79 | 0.00 | 0.00 | 0.00 |
| March | 44.90 | 0.00 | 44.90 | 46.28 | 97.37 | 0.00 | 0.00 | 0.00 |
| April | 53.12 | 0.31 | 52.81 | 74.10 | 57.94 | 0.00 | 0.00 | 0.00 |
| May | 60.12 | 2.26 | 57.86 | 130.13 | 10.94 | 0.00 | 0.00 | 0.00 |
| June | 68.16 | 4.64 | 63.51 | 152.88 | 8.87 | 0.00 | 0.00 | 0.00 |
| July | 66.19 | 2.47 | 63.72 | 148.71 | 5.30 | 0.00 | 0.00 | 0.00 |
| August | 59.52 | 0.61 | 58.91 | 132.25 | 9.82 | 0.00 | 0.00 | 0.00 |
| September | 51.25 | 0.01 | 51.24 | 103.88 | 17.05 | 0.00 | 0.00 | 0.00 |
| October | 44.52 | 0.00 | 44.52 | 81.70 | 36.50 | 0.00 | 0.00 | 0.00 |
| November | 33.80 | 0.00 | 33.80 | 32.81 | 93.71 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 22.49 | 125.05 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.68 | 0.86 | 47.82 | 81.74 | 59.89 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 21.09 | 5.30 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 68.16 | 4.64 | 63.72 | 152.88 | 142.86 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N N1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 32.80 | 0.00 | 32.80 | 20.75 | 147.82 | 0.00 | 0.00 | 0.00 |
| February | 38.70 | 0.00 | 38.70 | 30.49 | 121.40 | 0.00 | 0.00 | 0.00 |
| March | 44.90 | 0.00 | 44.90 | 46.17 | 100.86 | 0.00 | 0.00 | 0.00 |
| April | 53.12 | 0.31 | 52.81 | 74.72 | 58.80 | 0.00 | 0.00 | 0.00 |
| May | 60.12 | 2.26 | 57.86 | 131.55 | 10.76 | 0.00 | 0.00 | 0.00 |
| June | 68.16 | 4.64 | 63.51 | 154.62 | 8.61 | 0.00 | 0.00 | 0.00 |
| July | 66.19 | 2.47 | 63.72 | 150.87 | 4.98 | 0.00 | 0.00 | 0.00 |
| August | 59.52 | 0.61 | 58.91 | 134.42 | 9.21 | 0.00 | 0.00 | 0.00 |
| September | 51.25 | 0.01 | 51.24 | 105.63 | 16.30 | 0.00 | 0.00 | 0.00 |
| October | 44.52 | 0.00 | 44.52 | 83.28 | 35.97 | 0.00 | 0.00 | 0.00 |
| November | 33.80 | 0.00 | 33.80 | 33.53 | 93.92 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 22.39 | 128.31 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.68 | 0.86 | 47.82 | 82.69 | 61.10 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 20.75 | 4.98 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 68.16 | 4.64 | 63.72 | 154.62 | 147.82 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N N2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 32.80 | 0.00 | 32.80 | 20.73 | 147.83 | 0.00 | 0.00 | 0.00 |
| February | 38.70 | 0.00 | 38.70 | 30.47 | 121.41 | 0.00 | 0.00 | 0.00 |
| March | 44.90 | 0.00 | 44.90 | 46.13 | 100.88 | 0.00 | 0.00 | 0.00 |
| April | 53.12 | 0.31 | 52.81 | 74.69 | 58.80 | 0.00 | 0.00 | 0.00 |
| May | 60.12 | 2.26 | 57.86 | 131.53 | 10.77 | 0.00 | 0.00 | 0.00 |
| June | 68.16 | 4.64 | 63.51 | 154.61 | 8.61 | 0.00 | 0.00 | 0.00 |
| July | 66.19 | 2.47 | 63.72 | 150.86 | 4.98 | 0.00 | 0.00 | 0.00 |
| August | 59.52 | 0.61 | 58.91 | 134.42 | 9.20 | 0.00 | 0.00 | 0.00 |
| September | 51.25 | 0.01 | 51.24 | 105.62 | 16.29 | 0.00 | 0.00 | 0.00 |
| October | 44.52 | 0.00 | 44.52 | 83.28 | 35.95 | 0.00 | 0.00 | 0.00 |
| November | 33.80 | 0.00 | 33.80 | 33.51 | 93.91 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 22.40 | 128.25 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.68 | 0.86 | 47.82 | 82.67 | 61.10 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 20.73 | 4.98 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 68.16 | 4.64 | 63.72 | 154.61 | 147.83 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S S1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 187.72 | 133.34 | 54.38 | 270.74 | 133.34 | 0.00 | 0.00 | 0.00 |
| February | 173.17 | 112.51 | 60.65 | 255.54 | 113.03 | 0.00 | 0.00 | 0.00 |
| March | 108.35 | 48.13 | 60.23 | 164.59 | 98.90 | 0.00 | 0.00 | 0.00 |
| April | 83.19 | 20.88 | 62.31 | 141.35 | 60.44 | 0.00 | 0.00 | 0.00 |
| May | 62.38 | 2.83 | 59.55 | 137.83 | 11.26 | 0.00 | 0.00 | 0.00 |
| June | 61.48 | 0.64 | 60.84 | 140.33 | 9.05 | 0.00 | 0.00 | 0.00 |
| July | 64.33 | 1.21 | 63.12 | 147.82 | 4.90 | 0.00 | 0.00 | 0.00 |
| August | 75.00 | 8.43 | 66.57 | 168.81 | 9.75 | 0.00 | 0.00 | 0.00 |
| September | 91.98 | 25.14 | 66.84 | 188.51 | 16.97 | 0.00 | 0.00 | 0.00 |
| October | 138.27 | 70.82 | 67.46 | 258.37 | 35.94 | 0.00 | 0.00 | 0.00 |
| November | 179.89 | 124.07 | 55.82 | 283.32 | 86.41 | 0.00 | 0.00 | 0.00 |
| December | 184.96 | 132.74 | 52.21 | 278.27 | 117.82 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 117.25 | 56.42 | 60.83 | 202.68 | 57.86 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61.48 | 0.64 | 52.21 | 137.83 | 4.90 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 187.72 | 133.34 | 67.46 | 283.32 | 133.34 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S S2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 187.72 | 133.34 | 54.38 | 270.65 | 133.43 | 0.00 | 0.00 | 0.00 |
| February | 173.17 | 112.51 | 60.65 | 255.53 | 113.00 | 0.00 | 0.00 | 0.00 |
| March | 108.35 | 48.13 | 60.23 | 164.44 | 99.04 | 0.00 | 0.00 | 0.00 |
| April | 83.19 | 20.88 | 62.31 | 140.97 | 60.87 | 0.00 | 0.00 | 0.00 |
| May | 62.38 | 2.83 | 59.55 | 137.01 | 11.86 | 0.00 | 0.00 | 0.00 |
| June | 61.48 | 0.64 | 60.84 | 139.45 | 9.61 | 0.00 | 0.00 | 0.00 |
| July | 64.33 | 1.21 | 63.12 | 146.68 | 5.34 | 0.00 | 0.00 | 0.00 |
| August | 75.00 | 8.43 | 66.57 | 167.89 | 10.34 | 0.00 | 0.00 | 0.00 |
| September | 91.98 | 25.14 | 66.84 | 187.76 | 17.74 | 0.00 | 0.00 | 0.00 |
| October | 138.27 | 70.82 | 67.46 | 257.70 | 36.73 | 0.00 | 0.00 | 0.00 |
| November | 179.89 | 124.07 | 55.82 | 282.98 | 86.89 | 0.00 | 0.00 | 0.00 |
| December | 184.96 | 132.74 | 52.21 | 278.10 | 118.06 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 117.25 | 56.42 | 60.83 | 202.15 | 58.29 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61.48 | 0.64 | 52.21 | 137.01 | 5.34 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 187.72 | 133.34 | 67.46 | 282.98 | 133.43 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 187.72 | 133.34 | 54.38 | 269.27 | 132.36 | 0.00 | 0.00 | 0.00 |
| February | 173.17 | 112.51 | 60.65 | 252.86 | 114.19 | 0.00 | 0.00 | 0.00 |
| March | 108.35 | 48.13 | 60.23 | 161.44 | 101.28 | 0.00 | 0.00 | 0.00 |
| April | 83.19 | 20.88 | 62.31 | 137.96 | 63.43 | 0.00 | 0.00 | 0.00 |
| May | 62.38 | 2.83 | 59.55 | 135.89 | 11.81 | 0.00 | 0.00 | 0.00 |
| June | 61.48 | 0.64 | 60.84 | 138.59 | 9.39 | 0.00 | 0.00 | 0.00 |
| July | 64.33 | 1.21 | 63.12 | 146.86 | 4.78 | 0.00 | 0.00 | 0.00 |
| August | 75.00 | 8.43 | 66.57 | 168.64 | 9.13 | 0.00 | 0.00 | 0.00 |
| September | 91.98 | 25.14 | 66.84 | 188.30 | 15.88 | 0.00 | 0.00 | 0.00 |
| October | 138.27 | 70.82 | 67.46 | 257.93 | 34.67 | 0.00 | 0.00 | 0.00 |
| November | 179.89 | 124.07 | 55.82 | 282.61 | 85.23 | 0.00 | 0.00 | 0.00 |
| December | 184.96 | 132.74 | 52.21 | 277.41 | 116.24 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 117.25 | 56.42 | 60.83 | 201.22 | 57.90 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61.48 | 0.64 | 52.21 | 135.89 | 4.78 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 187.72 | 133.34 | 67.46 | 282.61 | 132.36 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 W SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 59.00 | 31.87 | 27.13 | 71.62 | 96.19 | 0.00 | 0.00 | 0.00 |
| February | 66.76 | 33.75 | 33.02 | 85.21 | 81.32 | 0.00 | 0.00 | 0.00 |
| March | 65.92 | 29.17 | 36.75 | 89.23 | 68.01 | 0.00 | 0.00 | 0.00 |
| April | 81.76 | 37.55 | 44.21 | 129.14 | 40.61 | 0.00 | 0.00 | 0.00 |
| May | 68.11 | 22.17 | 45.95 | 136.65 | 7.83 | 0.00 | 0.00 | 0.00 |
| June | 75.73 | 26.62 | 49.11 | 155.16 | 6.13 | 0.00 | 0.00 | 0.00 |
| July | 69.00 | 19.12 | 49.88 | 144.15 | 3.24 | 0.00 | 0.00 | 0.00 |
| August | 69.77 | 21.27 | 48.49 | 143.81 | 5.94 | 0.00 | 0.00 | 0.00 |
| September | 64.32 | 22.08 | 42.24 | 124.57 | 10.41 | 0.00 | 0.00 | 0.00 |
| October | 65.68 | 28.32 | 37.36 | 119.72 | 23.45 | 0.00 | 0.00 | 0.00 |
| November | 56.39 | 28.33 | 28.06 | 80.20 | 61.03 | 0.00 | 0.00 | 0.00 |
| December | 54.26 | 28.85 | 25.41 | 70.25 | 82.30 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.36 | 27.36 | 39.00 | 112.59 | 40.33 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 54.26 | 19.12 | 25.41 | 70.25 | 3.24 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 81.76 | 37.55 | 49.88 | 155.16 | 96.19 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 W NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 59.00 | 31.87 | 27.13 | 75.39 | 90.25 | 0.00 | 0.00 | 0.00 |
| February | 66.76 | 33.75 | 33.02 | 88.46 | 77.50 | 0.00 | 0.00 | 0.00 |
| March | 65.92 | 29.17 | 36.75 | 91.03 | 66.39 | 0.00 | 0.00 | 0.00 |
| April | 81.76 | 37.55 | 44.21 | 129.89 | 40.34 | 0.00 | 0.00 | 0.00 |
| May | 68.11 | 22.17 | 45.95 | 136.72 | 7.83 | 0.00 | 0.00 | 0.00 |
| June | 75.73 | 26.62 | 49.11 | 155.03 | 6.18 | 0.00 | 0.00 | 0.00 |
| July | 69.00 | 19.12 | 49.88 | 144.09 | 3.25 | 0.00 | 0.00 | 0.00 |
| August | 69.77 | 21.27 | 48.49 | 144.13 | 5.88 | 0.00 | 0.00 | 0.00 |
| September | 64.32 | 22.08 | 42.24 | 125.27 | 10.11 | 0.00 | 0.00 | 0.00 |
| October | 65.68 | 28.32 | 37.36 | 121.24 | 22.64 | 0.00 | 0.00 | 0.00 |
| November | 56.39 | 28.33 | 28.06 | 82.77 | 58.87 | 0.00 | 0.00 | 0.00 |
| December | 54.26 | 28.85 | 25.41 | 73.36 | 77.91 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.36 | 27.36 | 39.00 | 114.06 | 38.72 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 54.26 | 19.12 | 25.41 | 73.36 | 3.25 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 81.76 | 37.55 | 49.88 | 155.03 | 90.25 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 32.80 | 0.00 | 32.80 | 20.53 | 146.41 | 0.00 | 0.00 | 0.00 |
| February | 38.70 | 0.00 | 38.70 | 28.61 | 124.69 | 0.00 | 0.00 | 0.00 |
| March | 44.90 | 0.00 | 44.90 | 43.32 | 105.16 | 0.00 | 0.00 | 0.00 |
| April | 53.12 | 0.31 | 52.81 | 71.37 | 62.53 | 0.00 | 0.00 | 0.00 |
| May | 60.12 | 2.26 | 57.86 | 129.58 | 11.31 | 0.00 | 0.00 | 0.00 |
| June | 68.16 | 4.64 | 63.51 | 152.85 | 8.88 | 0.00 | 0.00 | 0.00 |
| July | 66.19 | 2.47 | 63.72 | 149.86 | 4.86 | 0.00 | 0.00 | 0.00 |
| August | 59.52 | 0.61 | 58.91 | 134.40 | 8.63 | 0.00 | 0.00 | 0.00 |
| September | 51.25 | 0.01 | 51.24 | 105.72 | 15.40 | 0.00 | 0.00 | 0.00 |
| October | 44.52 | 0.00 | 44.52 | 83.49 | 35.01 | 0.00 | 0.00 | 0.00 |
| November | 33.80 | 0.00 | 33.80 | 33.73 | 93.43 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 22.71 | 125.89 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.68 | 0.86 | 47.82 | 81.68 | 61.51 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 20.53 | 4.86 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 68.16 | 4.64 | 63.72 | 152.85 | 146.41 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 187.72 | 133.34 | 54.38 | 268.74 | 131.97 | 0.00 | 0.00 | 0.00 |
| February | 173.17 | 112.51 | 60.65 | 252.28 | 113.65 | 0.00 | 0.00 | 0.00 |
| March | 108.35 | 48.13 | 60.23 | 160.47 | 101.08 | 0.00 | 0.00 | 0.00 |
| April | 83.19 | 20.88 | 62.31 | 137.10 | 63.08 | 0.00 | 0.00 | 0.00 |
| May | 62.38 | 2.83 | 59.55 | 135.40 | 11.74 | 0.00 | 0.00 | 0.00 |
| June | 61.48 | 0.64 | 60.84 | 138.22 | 9.28 | 0.00 | 0.00 | 0.00 |
| July | 64.33 | 1.21 | 63.12 | 146.48 | 4.74 | 0.00 | 0.00 | 0.00 |
| August | 75.00 | 8.43 | 66.57 | 168.43 | 9.00 | 0.00 | 0.00 | 0.00 |
| September | 91.98 | 25.14 | 66.84 | 188.13 | 15.70 | 0.00 | 0.00 | 0.00 |
| October | 138.27 | 70.82 | 67.46 | 257.65 | 34.37 | 0.00 | 0.00 | 0.00 |
| November | 179.89 | 124.07 | 55.82 | 282.03 | 84.92 | 0.00 | 0.00 | 0.00 |
| December | 184.96 | 132.74 | 52.21 | 277.21 | 115.65 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 117.25 | 56.42 | 60.83 | 200.75 | 57.63 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61.48 | 0.64 | 52.21 | 135.40 | 4.74 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 187.72 | 133.34 | 67.46 | 282.03 | 131.97 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 E SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 55.78 | 28.52 | 27.26 | 62.23 | 92.58 | 0.00 | 0.00 | 0.00 |
| February | 61.71 | 29.68 | 32.03 | 73.60 | 77.79 | 0.00 | 0.00 | 0.00 |
| March | 72.77 | 35.05 | 37.73 | 96.90 | 64.75 | 0.00 | 0.00 | 0.00 |
| April | 80.05 | 36.26 | 43.79 | 123.97 | 39.12 | 0.00 | 0.00 | 0.00 |
| May | 82.35 | 35.73 | 46.61 | 160.27 | 7.25 | 0.00 | 0.00 | 0.00 |
| June | 83.47 | 33.12 | 50.36 | 168.46 | 5.65 | 0.00 | 0.00 | 0.00 |
| July | 80.54 | 29.51 | 51.02 | 164.65 | 2.99 | 0.00 | 0.00 | 0.00 |
| August | 74.18 | 25.48 | 48.70 | 150.35 | 5.53 | 0.00 | 0.00 | 0.00 |
| September | 65.61 | 22.51 | 43.10 | 125.91 | 9.94 | 0.00 | 0.00 | 0.00 |
| October | 65.07 | 27.53 | 37.53 | 116.18 | 22.28 | 0.00 | 0.00 | 0.00 |
| November | 57.48 | 29.31 | 28.17 | 77.54 | 57.90 | 0.00 | 0.00 | 0.00 |
| December | 45.29 | 20.54 | 24.75 | 52.59 | 80.91 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 68.72 | 29.43 | 39.29 | 114.62 | 38.69 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 45.29 | 20.54 | 24.75 | 52.59 | 2.99 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 83.47 | 36.26 | 51.02 | 168.46 | 92.58 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 E NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 55.78 | 28.52 | 27.26 | 65.54 | 86.29 | 0.00 | 0.00 | 0.00 |
| February | 61.71 | 29.68 | 32.03 | 76.50 | 73.62 | 0.00 | 0.00 | 0.00 |
| March | 72.77 | 35.05 | 37.73 | 98.62 | 62.97 | 0.00 | 0.00 | 0.00 |
| April | 80.05 | 36.26 | 43.79 | 124.67 | 38.82 | 0.00 | 0.00 | 0.00 |
| May | 82.35 | 35.73 | 46.61 | 160.34 | 7.24 | 0.00 | 0.00 | 0.00 |
| June | 83.47 | 33.12 | 50.36 | 168.33 | 5.69 | 0.00 | 0.00 | 0.00 |
| July | 80.54 | 29.51 | 51.02 | 164.59 | 3.00 | 0.00 | 0.00 | 0.00 |
| August | 74.18 | 25.48 | 48.70 | 150.68 | 5.47 | 0.00 | 0.00 | 0.00 |
| September | 65.61 | 22.51 | 43.10 | 126.62 | 9.64 | 0.00 | 0.00 | 0.00 |
| October | 65.07 | 27.53 | 37.53 | 117.72 | 21.38 | 0.00 | 0.00 | 0.00 |
| November | 57.48 | 29.31 | 28.17 | 79.92 | 55.39 | 0.00 | 0.00 | 0.00 |
| December | 45.29 | 20.54 | 24.75 | 55.40 | 75.97 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 68.72 | 29.43 | 39.29 | 115.97 | 36.93 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 45.29 | 20.54 | 24.75 | 55.40 | 3.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 83.47 | 36.26 | 51.02 | 168.33 | 86.29 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 32.80 | 0.00 | 32.80 | 20.03 | 146.10 | 0.00 | 0.00 | 0.00 |
| February | 38.70 | 0.00 | 38.70 | 28.07 | 124.11 | 0.00 | 0.00 | 0.00 |
| March | 44.90 | 0.00 | 44.90 | 42.45 | 104.88 | 0.00 | 0.00 | 0.00 |
| April | 53.12 | 0.31 | 52.81 | 70.50 | 62.18 | 0.00 | 0.00 | 0.00 |
| May | 60.12 | 2.26 | 57.86 | 129.11 | 11.22 | 0.00 | 0.00 | 0.00 |
| June | 68.16 | 4.64 | 63.51 | 152.49 | 8.77 | 0.00 | 0.00 | 0.00 |
| July | 66.19 | 2.47 | 63.72 | 149.49 | 4.82 | 0.00 | 0.00 | 0.00 |
| August | 59.52 | 0.61 | 58.91 | 134.19 | 8.50 | 0.00 | 0.00 | 0.00 |
| September | 51.25 | 0.01 | 51.24 | 105.54 | 15.22 | 0.00 | 0.00 | 0.00 |
| October | 44.52 | 0.00 | 44.52 | 83.19 | 34.59 | 0.00 | 0.00 | 0.00 |
| November | 33.80 | 0.00 | 33.80 | 33.18 | 92.92 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 22.54 | 124.97 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.68 | 0.86 | 47.82 | 81.23 | 61.19 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 20.03 | 4.82 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 68.16 | 4.64 | 63.72 | 152.49 | 146.10 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N N1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 32.80 | 0.00 | 32.80 | 19.72 | 151.75 | 0.00 | 0.00 | 0.00 |
| February | 38.70 | 0.00 | 38.70 | 28.28 | 127.50 | 0.00 | 0.00 | 0.00 |
| March | 44.90 | 0.00 | 44.90 | 43.31 | 106.74 | 0.00 | 0.00 | 0.00 |
| April | 53.12 | 0.31 | 52.81 | 72.29 | 61.71 | 0.00 | 0.00 | 0.00 |
| May | 60.12 | 2.26 | 57.86 | 131.15 | 10.76 | 0.00 | 0.00 | 0.00 |
| June | 68.16 | 4.64 | 63.51 | 154.71 | 8.34 | 0.00 | 0.00 | 0.00 |
| July | 66.19 | 2.47 | 63.72 | 151.84 | 4.52 | 0.00 | 0.00 | 0.00 |
| August | 59.52 | 0.61 | 58.91 | 136.18 | 8.10 | 0.00 | 0.00 | 0.00 |
| September | 51.25 | 0.01 | 51.24 | 107.12 | 14.77 | 0.00 | 0.00 | 0.00 |
| October | 44.52 | 0.00 | 44.52 | 84.64 | 34.42 | 0.00 | 0.00 | 0.00 |
| November | 33.80 | 0.00 | 33.80 | 33.85 | 93.56 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 22.33 | 129.30 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.68 | 0.86 | 47.82 | 82.45 | 62.29 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 19.72 | 4.52 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 68.16 | 4.64 | 63.72 | 154.71 | 151.75 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N N2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 32.80 | 0.00 | 32.80 | 19.70 | 151.78 | 0.00 | 0.00 | 0.00 |
| February | 38.70 | 0.00 | 38.70 | 28.25 | 127.48 | 0.00 | 0.00 | 0.00 |
| March | 44.90 | 0.00 | 44.90 | 43.26 | 106.76 | 0.00 | 0.00 | 0.00 |
| April | 53.12 | 0.31 | 52.81 | 72.24 | 61.72 | 0.00 | 0.00 | 0.00 |
| May | 60.12 | 2.26 | 57.86 | 131.13 | 10.76 | 0.00 | 0.00 | 0.00 |
| June | 68.16 | 4.64 | 63.51 | 154.70 | 8.34 | 0.00 | 0.00 | 0.00 |
| July | 66.19 | 2.47 | 63.72 | 151.82 | 4.52 | 0.00 | 0.00 | 0.00 |
| August | 59.52 | 0.61 | 58.91 | 136.17 | 8.10 | 0.00 | 0.00 | 0.00 |
| September | 51.25 | 0.01 | 51.24 | 107.11 | 14.77 | 0.00 | 0.00 | 0.00 |
| October | 44.52 | 0.00 | 44.52 | 84.63 | 34.40 | 0.00 | 0.00 | 0.00 |
| November | 33.80 | 0.00 | 33.80 | 33.82 | 93.55 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 22.33 | 129.23 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.68 | 0.86 | 47.82 | 82.43 | 62.28 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 19.70 | 4.52 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 68.16 | 4.64 | 63.72 | 154.70 | 151.78 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S S1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 187.72 | 133.34 | 54.38 | 268.35 | 134.42 | 0.00 | 0.00 | 0.00 |
| February | 173.17 | 112.51 | 60.65 | 252.29 | 115.61 | 0.00 | 0.00 | 0.00 |
| March | 108.35 | 48.13 | 60.23 | 161.35 | 102.50 | 0.00 | 0.00 | 0.00 |
| April | 83.19 | 20.88 | 62.31 | 138.73 | 62.91 | 0.00 | 0.00 | 0.00 |
| May | 62.38 | 2.83 | 59.55 | 137.44 | 11.25 | 0.00 | 0.00 | 0.00 |
| June | 61.48 | 0.64 | 60.84 | 140.43 | 8.83 | 0.00 | 0.00 | 0.00 |
| July | 64.33 | 1.21 | 63.12 | 148.86 | 4.43 | 0.00 | 0.00 | 0.00 |
| August | 75.00 | 8.43 | 66.57 | 170.38 | 8.61 | 0.00 | 0.00 | 0.00 |
| September | 91.98 | 25.14 | 66.84 | 189.62 | 15.29 | 0.00 | 0.00 | 0.00 |
| October | 138.27 | 70.82 | 67.46 | 258.90 | 34.29 | 0.00 | 0.00 | 0.00 |
| November | 179.89 | 124.07 | 55.82 | 282.55 | 85.69 | 0.00 | 0.00 | 0.00 |
| December | 184.96 | 132.74 | 52.21 | 276.86 | 117.85 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 117.25 | 56.42 | 60.83 | 201.89 | 58.17 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61.48 | 0.64 | 52.21 | 137.44 | 4.43 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 187.72 | 133.34 | 67.46 | 282.55 | 134.42 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S S2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 187.72 | 133.34 | 54.38 | 268.33 | 134.42 | 0.00 | 0.00 | 0.00 |
| February | 173.17 | 112.51 | 60.65 | 252.27 | 115.59 | 0.00 | 0.00 | 0.00 |
| March | 108.35 | 48.13 | 60.23 | 161.30 | 102.50 | 0.00 | 0.00 | 0.00 |
| April | 83.19 | 20.88 | 62.31 | 138.69 | 62.91 | 0.00 | 0.00 | 0.00 |
| May | 62.38 | 2.83 | 59.55 | 137.42 | 11.25 | 0.00 | 0.00 | 0.00 |
| June | 61.48 | 0.64 | 60.84 | 140.42 | 8.82 | 0.00 | 0.00 | 0.00 |
| July | 64.33 | 1.21 | 63.12 | 148.85 | 4.43 | 0.00 | 0.00 | 0.00 |
| August | 75.00 | 8.43 | 66.57 | 170.37 | 8.60 | 0.00 | 0.00 | 0.00 |
| September | 91.98 | 25.14 | 66.84 | 189.61 | 15.28 | 0.00 | 0.00 | 0.00 |
| October | 138.27 | 70.82 | 67.46 | 258.89 | 34.28 | 0.00 | 0.00 | 0.00 |
| November | 179.89 | 124.07 | 55.82 | 282.52 | 85.68 | 0.00 | 0.00 | 0.00 |
| December | 184.96 | 132.74 | 52.21 | 276.86 | 117.82 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 117.25 | 56.42 | 60.83 | 201.87 | 58.16 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61.48 | 0.64 | 52.21 | 137.42 | 4.43 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 187.72 | 133.34 | 67.46 | 282.52 | 134.42 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 187.72 | 133.34 | 54.38 | 272.31 | 119.86 | 0.00 | 0.00 | 0.00 |
| February | 173.17 | 112.51 | 60.65 | 254.10 | 105.42 | 0.00 | 0.00 | 0.00 |
| March | 108.35 | 48.13 | 60.23 | 162.09 | 92.87 | 0.00 | 0.00 | 0.00 |
| April | 83.19 | 20.88 | 62.31 | 135.81 | 61.43 | 0.00 | 0.00 | 0.00 |
| May | 62.38 | 2.83 | 59.55 | 132.09 | 11.68 | 0.00 | 0.00 | 0.00 |
| June | 61.48 | 0.64 | 60.84 | 134.42 | 9.33 | 0.00 | 0.00 | 0.00 |
| July | 64.33 | 1.21 | 63.12 | 142.50 | 4.78 | 0.00 | 0.00 | 0.00 |
| August | 75.00 | 8.43 | 66.57 | 164.41 | 9.10 | 0.00 | 0.00 | 0.00 |
| September | 91.98 | 25.14 | 66.84 | 184.62 | 15.84 | 0.00 | 0.00 | 0.00 |
| October | 138.27 | 70.82 | 67.46 | 254.62 | 33.50 | 0.00 | 0.00 | 0.00 |
| November | 179.89 | 124.07 | 55.82 | 281.78 | 80.62 | 0.00 | 0.00 | 0.00 |
| December | 184.96 | 132.74 | 52.21 | 278.90 | 105.48 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 117.25 | 56.42 | 60.83 | 199.53 | 53.87 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61.48 | 0.64 | 52.21 | 132.09 | 4.78 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 187.72 | 133.34 | 67.46 | 281.78 | 119.86 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 W SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 59.00 | 31.87 | 27.13 | 71.52 | 85.74 | 0.00 | 0.00 | 0.00 |
| February | 66.76 | 33.75 | 33.02 | 84.57 | 74.00 | 0.00 | 0.00 | 0.00 |
| March | 65.92 | 29.17 | 36.75 | 88.93 | 61.74 | 0.00 | 0.00 | 0.00 |
| April | 81.76 | 37.55 | 44.21 | 127.28 | 39.00 | 0.00 | 0.00 | 0.00 |
| May | 68.11 | 22.17 | 45.95 | 134.08 | 7.72 | 0.00 | 0.00 | 0.00 |
| June | 75.73 | 26.62 | 49.11 | 152.22 | 6.05 | 0.00 | 0.00 | 0.00 |
| July | 69.00 | 19.12 | 49.88 | 141.10 | 3.21 | 0.00 | 0.00 | 0.00 |
| August | 69.77 | 21.27 | 48.49 | 140.94 | 5.89 | 0.00 | 0.00 | 0.00 |
| September | 64.32 | 22.08 | 42.24 | 122.11 | 10.33 | 0.00 | 0.00 | 0.00 |
| October | 65.68 | 28.32 | 37.36 | 117.47 | 22.52 | 0.00 | 0.00 | 0.00 |
| November | 56.39 | 28.33 | 28.06 | 78.81 | 57.09 | 0.00 | 0.00 | 0.00 |
| December | 54.26 | 28.85 | 25.41 | 69.77 | 73.65 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.36 | 27.36 | 39.00 | 110.85 | 37.04 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 54.26 | 19.12 | 25.41 | 69.77 | 3.21 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 81.76 | 37.55 | 49.88 | 152.22 | 85.74 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 W NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 59.00 | 31.87 | 27.13 | 77.66 | 79.81 | 0.00 | 0.00 | 0.00 |
| February | 66.76 | 33.75 | 33.02 | 89.70 | 69.99 | 0.00 | 0.00 | 0.00 |
| March | 65.92 | 29.17 | 36.75 | 91.69 | 60.13 | 0.00 | 0.00 | 0.00 |
| April | 81.76 | 37.55 | 44.21 | 128.29 | 38.95 | 0.00 | 0.00 | 0.00 |
| May | 68.11 | 22.17 | 45.95 | 134.15 | 7.74 | 0.00 | 0.00 | 0.00 |
| June | 75.73 | 26.62 | 49.11 | 152.05 | 6.09 | 0.00 | 0.00 | 0.00 |
| July | 69.00 | 19.12 | 49.88 | 141.02 | 3.22 | 0.00 | 0.00 | 0.00 |
| August | 69.77 | 21.27 | 48.49 | 141.38 | 5.86 | 0.00 | 0.00 | 0.00 |
| September | 64.32 | 22.08 | 42.24 | 123.07 | 10.11 | 0.00 | 0.00 | 0.00 |
| October | 65.68 | 28.32 | 37.36 | 119.77 | 21.67 | 0.00 | 0.00 | 0.00 |
| November | 56.39 | 28.33 | 28.06 | 83.49 | 53.73 | 0.00 | 0.00 | 0.00 |
| December | 54.26 | 28.85 | 25.41 | 75.17 | 68.25 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 66.36 | 27.36 | 39.00 | 113.22 | 35.27 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 54.26 | 19.12 | 25.41 | 75.17 | 3.22 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 81.76 | 37.55 | 49.88 | 152.05 | 79.81 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 32.80 | 0.00 | 32.80 | 23.12 | 129.38 | 0.00 | 0.00 | 0.00 |
| February | 38.70 | 0.00 | 38.70 | 30.31 | 112.82 | 0.00 | 0.00 | 0.00 |
| March | 44.90 | 0.00 | 44.90 | 44.71 | 95.67 | 0.00 | 0.00 | 0.00 |
| April | 53.12 | 0.31 | 52.81 | 69.82 | 60.92 | 0.00 | 0.00 | 0.00 |
| May | 60.12 | 2.26 | 57.86 | 125.89 | 11.23 | 0.00 | 0.00 | 0.00 |
| June | 68.16 | 4.64 | 63.51 | 148.59 | 8.79 | 0.00 | 0.00 | 0.00 |
| July | 66.19 | 2.47 | 63.72 | 145.50 | 4.85 | 0.00 | 0.00 | 0.00 |
| August | 59.52 | 0.61 | 58.91 | 130.46 | 8.61 | 0.00 | 0.00 | 0.00 |
| September | 51.25 | 0.01 | 51.24 | 102.57 | 15.46 | 0.00 | 0.00 | 0.00 |
| October | 44.52 | 0.00 | 44.52 | 81.49 | 33.60 | 0.00 | 0.00 | 0.00 |
| November | 33.80 | 0.00 | 33.80 | 34.97 | 85.58 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 24.76 | 110.23 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.68 | 0.86 | 47.82 | 80.49 | 56.11 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 23.12 | 4.85 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 68.16 | 4.64 | 63.72 | 148.59 | 129.38 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 187.72 | 133.34 | 54.38 | 270.79 | 118.96 | 0.00 | 0.00 | 0.00 |
| February | 173.17 | 112.51 | 60.65 | 252.71 | 104.24 | 0.00 | 0.00 | 0.00 |
| March | 108.35 | 48.13 | 60.23 | 160.08 | 92.16 | 0.00 | 0.00 | 0.00 |
| April | 83.19 | 20.88 | 62.31 | 134.22 | 60.63 | 0.00 | 0.00 | 0.00 |
| May | 62.38 | 2.83 | 59.55 | 131.41 | 11.50 | 0.00 | 0.00 | 0.00 |
| June | 61.48 | 0.64 | 60.84 | 133.89 | 9.12 | 0.00 | 0.00 | 0.00 |
| July | 64.33 | 1.21 | 63.12 | 141.98 | 4.68 | 0.00 | 0.00 | 0.00 |
| August | 75.00 | 8.43 | 66.57 | 164.12 | 8.89 | 0.00 | 0.00 | 0.00 |
| September | 91.98 | 25.14 | 66.84 | 184.33 | 15.55 | 0.00 | 0.00 | 0.00 |
| October | 138.27 | 70.82 | 67.46 | 254.11 | 32.98 | 0.00 | 0.00 | 0.00 |
| November | 179.89 | 124.07 | 55.82 | 280.58 | 79.91 | 0.00 | 0.00 | 0.00 |
| December | 184.96 | 132.74 | 52.21 | 278.17 | 104.48 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 117.25 | 56.42 | 60.83 | 198.59 | 53.31 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61.48 | 0.64 | 52.21 | 131.41 | 4.68 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 187.72 | 133.34 | 67.46 | 280.58 | 118.96 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 E SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 55.78 | 28.52 | 27.26 | 64.08 | 84.23 | 0.00 | 0.00 | 0.00 |
| February | 61.71 | 29.68 | 32.03 | 74.53 | 71.94 | 0.00 | 0.00 | 0.00 |
| March | 72.77 | 35.05 | 37.73 | 97.39 | 59.45 | 0.00 | 0.00 | 0.00 |
| April | 80.05 | 36.26 | 43.79 | 122.45 | 37.87 | 0.00 | 0.00 | 0.00 |
| May | 82.35 | 35.73 | 46.61 | 157.42 | 7.10 | 0.00 | 0.00 | 0.00 |
| June | 83.47 | 33.12 | 50.36 | 165.43 | 5.55 | 0.00 | 0.00 | 0.00 |
| July | 80.54 | 29.51 | 51.02 | 161.55 | 2.94 | 0.00 | 0.00 | 0.00 |
| August | 74.18 | 25.48 | 48.70 | 147.41 | 5.45 | 0.00 | 0.00 | 0.00 |
| September | 65.61 | 22.51 | 43.10 | 123.35 | 9.83 | 0.00 | 0.00 | 0.00 |
| October | 65.07 | 27.53 | 37.53 | 113.92 | 21.47 | 0.00 | 0.00 | 0.00 |
| November | 57.48 | 29.31 | 28.17 | 77.09 | 55.01 | 0.00 | 0.00 | 0.00 |
| December | 45.29 | 20.54 | 24.75 | 53.45 | 73.57 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 68.72 | 29.43 | 39.29 | 113.39 | 36.01 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 45.29 | 20.54 | 24.75 | 53.45 | 2.94 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 83.47 | 36.26 | 51.02 | 165.43 | 84.23 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 E NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 55.78 | 28.52 | 27.26 | 68.78 | 76.22 | 0.00 | 0.00 | 0.00 |
| February | 61.71 | 29.68 | 32.03 | 78.62 | 66.72 | 0.00 | 0.00 | 0.00 |
| March | 72.77 | 35.05 | 37.73 | 99.96 | 57.39 | 0.00 | 0.00 | 0.00 |
| April | 80.05 | 36.26 | 43.79 | 123.40 | 37.66 | 0.00 | 0.00 | 0.00 |
| May | 82.35 | 35.73 | 46.61 | 157.50 | 7.11 | 0.00 | 0.00 | 0.00 |
| June | 83.47 | 33.12 | 50.36 | 165.26 | 5.59 | 0.00 | 0.00 | 0.00 |
| July | 80.54 | 29.51 | 51.02 | 161.48 | 2.95 | 0.00 | 0.00 | 0.00 |
| August | 74.18 | 25.48 | 48.70 | 147.84 | 5.42 | 0.00 | 0.00 | 0.00 |
| September | 65.61 | 22.51 | 43.10 | 124.30 | 9.60 | 0.00 | 0.00 | 0.00 |
| October | 65.07 | 27.53 | 37.53 | 116.21 | 20.37 | 0.00 | 0.00 | 0.00 |
| November | 57.48 | 29.31 | 28.17 | 81.28 | 51.00 | 0.00 | 0.00 | 0.00 |
| December | 45.29 | 20.54 | 24.75 | 57.85 | 66.76 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 68.72 | 29.43 | 39.29 | 115.42 | 33.72 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 45.29 | 20.54 | 24.75 | 57.85 | 2.95 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 83.47 | 36.26 | 51.02 | 165.26 | 76.22 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 32.80 | 0.00 | 32.80 | 22.01 | 127.68 | 0.00 | 0.00 | 0.00 |
| February | 38.70 | 0.00 | 38.70 | 28.99 | 111.28 | 0.00 | 0.00 | 0.00 |
| March | 44.90 | 0.00 | 44.90 | 42.95 | 94.69 | 0.00 | 0.00 | 0.00 |
| April | 53.12 | 0.31 | 52.81 | 68.23 | 59.91 | 0.00 | 0.00 | 0.00 |
| May | 60.12 | 2.26 | 57.86 | 125.23 | 11.04 | 0.00 | 0.00 | 0.00 |
| June | 68.16 | 4.64 | 63.51 | 148.08 | 8.59 | 0.00 | 0.00 | 0.00 |
| July | 66.19 | 2.47 | 63.72 | 145.00 | 4.75 | 0.00 | 0.00 | 0.00 |
| August | 59.52 | 0.61 | 58.91 | 130.17 | 8.41 | 0.00 | 0.00 | 0.00 |
| September | 51.25 | 0.01 | 51.24 | 102.28 | 15.17 | 0.00 | 0.00 | 0.00 |
| October | 44.52 | 0.00 | 44.52 | 80.91 | 32.79 | 0.00 | 0.00 | 0.00 |
| November | 33.80 | 0.00 | 33.80 | 33.60 | 84.52 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 24.05 | 108.61 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.68 | 0.86 | 47.82 | 79.61 | 55.31 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 22.01 | 4.75 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 68.16 | 4.64 | 63.72 | 148.08 | 127.68 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N N1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 32.80 | 0.00 | 32.80 | 22.97 | 131.04 | 0.00 | 0.00 | 0.00 |
| February | 38.70 | 0.00 | 38.70 | 30.27 | 114.28 | 0.00 | 0.00 | 0.00 |
| March | 44.90 | 0.00 | 44.90 | 44.98 | 96.99 | 0.00 | 0.00 | 0.00 |
| April | 53.12 | 0.31 | 52.81 | 70.77 | 60.65 | 0.00 | 0.00 | 0.00 |
| May | 60.12 | 2.26 | 57.86 | 127.84 | 10.86 | 0.00 | 0.00 | 0.00 |
| June | 68.16 | 4.64 | 63.51 | 150.90 | 8.41 | 0.00 | 0.00 | 0.00 |
| July | 66.19 | 2.47 | 63.72 | 147.88 | 4.61 | 0.00 | 0.00 | 0.00 |
| August | 59.52 | 0.61 | 58.91 | 132.69 | 8.26 | 0.00 | 0.00 | 0.00 |
| September | 51.25 | 0.01 | 51.24 | 104.35 | 15.08 | 0.00 | 0.00 | 0.00 |
| October | 44.52 | 0.00 | 44.52 | 82.89 | 33.39 | 0.00 | 0.00 | 0.00 |
| November | 33.80 | 0.00 | 33.80 | 34.89 | 87.01 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 24.63 | 112.48 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.68 | 0.86 | 47.82 | 81.58 | 56.61 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 22.97 | 4.61 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 68.16 | 4.64 | 63.72 | 150.90 | 131.04 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N N2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 32.80 | 0.00 | 32.80 | 22.90 | 130.92 | 0.00 | 0.00 | 0.00 |
| February | 38.70 | 0.00 | 38.70 | 30.18 | 114.17 | 0.00 | 0.00 | 0.00 |
| March | 44.90 | 0.00 | 44.90 | 44.84 | 96.93 | 0.00 | 0.00 | 0.00 |
| April | 53.12 | 0.31 | 52.81 | 70.64 | 60.60 | 0.00 | 0.00 | 0.00 |
| May | 60.12 | 2.26 | 57.86 | 127.81 | 10.85 | 0.00 | 0.00 | 0.00 |
| June | 68.16 | 4.64 | 63.51 | 150.88 | 8.40 | 0.00 | 0.00 | 0.00 |
| July | 66.19 | 2.47 | 63.72 | 147.86 | 4.61 | 0.00 | 0.00 | 0.00 |
| August | 59.52 | 0.61 | 58.91 | 132.68 | 8.24 | 0.00 | 0.00 | 0.00 |
| September | 51.25 | 0.01 | 51.24 | 104.34 | 15.06 | 0.00 | 0.00 | 0.00 |
| October | 44.52 | 0.00 | 44.52 | 82.85 | 33.33 | 0.00 | 0.00 | 0.00 |
| November | 33.80 | 0.00 | 33.80 | 34.78 | 86.95 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 24.59 | 112.33 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 48.68 | 0.86 | 47.82 | 81.52 | 56.55 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 22.90 | 4.61 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 68.16 | 4.64 | 63.72 | 150.88 | 130.92 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S S1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 187.72 | 133.34 | 54.38 | 270.84 | 123.54 | 0.00 | 0.00 | 0.00 |
| February | 173.17 | 112.51 | 60.65 | 253.24 | 107.83 | 0.00 | 0.00 | 0.00 |
| March | 108.35 | 48.13 | 60.23 | 161.83 | 94.77 | 0.00 | 0.00 | 0.00 |
| April | 83.19 | 20.88 | 62.31 | 136.60 | 61.47 | 0.00 | 0.00 | 0.00 |
| May | 62.38 | 2.83 | 59.55 | 134.05 | 11.31 | 0.00 | 0.00 | 0.00 |
| June | 61.48 | 0.64 | 60.84 | 136.71 | 8.92 | 0.00 | 0.00 | 0.00 |
| July | 64.33 | 1.21 | 63.12 | 144.92 | 4.54 | 0.00 | 0.00 | 0.00 |
| August | 75.00 | 8.43 | 66.57 | 166.60 | 8.74 | 0.00 | 0.00 | 0.00 |
| September | 91.98 | 25.14 | 66.84 | 186.30 | 15.48 | 0.00 | 0.00 | 0.00 |
| October | 138.27 | 70.82 | 67.46 | 255.76 | 33.50 | 0.00 | 0.00 | 0.00 |
| November | 179.89 | 124.07 | 55.82 | 281.23 | 82.20 | 0.00 | 0.00 | 0.00 |
| December | 184.96 | 132.74 | 52.21 | 277.78 | 108.78 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 117.25 | 56.42 | 60.83 | 200.22 | 54.80 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61.48 | 0.64 | 52.21 | 134.05 | 4.54 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 187.72 | 133.34 | 67.46 | 281.23 | 123.54 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S S2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 187.72 | 133.34 | 54.38 | 270.73 | 123.49 | 0.00 | 0.00 | 0.00 |
| February | 173.17 | 112.51 | 60.65 | 253.14 | 107.75 | 0.00 | 0.00 | 0.00 |
| March | 108.35 | 48.13 | 60.23 | 161.68 | 94.76 | 0.00 | 0.00 | 0.00 |
| April | 83.19 | 20.88 | 62.31 | 136.49 | 61.43 | 0.00 | 0.00 | 0.00 |
| May | 62.38 | 2.83 | 59.55 | 134.01 | 11.30 | 0.00 | 0.00 | 0.00 |
| June | 61.48 | 0.64 | 60.84 | 136.68 | 8.91 | 0.00 | 0.00 | 0.00 |
| July | 64.33 | 1.21 | 63.12 | 144.89 | 4.53 | 0.00 | 0.00 | 0.00 |
| August | 75.00 | 8.43 | 66.57 | 166.59 | 8.73 | 0.00 | 0.00 | 0.00 |
| September | 91.98 | 25.14 | 66.84 | 186.28 | 15.46 | 0.00 | 0.00 | 0.00 |
| October | 138.27 | 70.82 | 67.46 | 255.73 | 33.46 | 0.00 | 0.00 | 0.00 |
| November | 179.89 | 124.07 | 55.82 | 281.15 | 82.16 | 0.00 | 0.00 | 0.00 |
| December | 184.96 | 132.74 | 52.21 | 277.74 | 108.70 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 117.25 | 56.42 | 60.83 | 200.16 | 54.77 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61.48 | 0.64 | 52.21 | 134.01 | 4.53 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 187.72 | 133.34 | 67.46 | 281.15 | 123.49 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW14
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 13.38 | 6.84 | 6.54 | 15.43 | 21.46 | 499.17 | 0.00 | 0.00 |
| February | 14.81 | 7.12 | 7.69 | 17.81 | 18.68 | 443.33 | 0.00 | 0.00 |
| March | 17.46 | 8.41 | 9.05 | 22.94 | 16.05 | 452.67 | 0.00 | 0.00 |
| April | 19.21 | 8.70 | 10.51 | 28.41 | 10.82 | 401.67 | 0.00 | 0.00 |
| May | 19.76 | 8.57 | 11.19 | 35.71 | 3.07 | 314.83 | 0.00 | 0.00 |
| June | 20.03 | 7.95 | 12.08 | 37.58 | 2.65 | 290.17 | 0.00 | 0.00 |
| July | 19.33 | 7.08 | 12.24 | 36.37 | 1.76 | 230.67 | 0.00 | 0.00 |
| August | 17.80 | 6.11 | 11.68 | 33.23 | 2.54 | 289.50 | 0.00 | 0.00 |
| September | 15.74 | 5.40 | 10.34 | 27.92 | 3.83 | 344.83 | 0.00 | 0.00 |
| October | 15.61 | 6.61 | 9.01 | 26.09 | 6.77 | 379.50 | 0.00 | 0.00 |
| November | 13.79 | 7.03 | 6.76 | 18.29 | 14.75 | 446.17 | 0.00 | 0.00 |
| December | 10.87 | 4.93 | 5.94 | 12.77 | 19.13 | 511.50 | 0.00 | 0.00 |
| Annual Sum or Average | 16.49 | 7.06 | 9.43 | 26.09 | 10.08 | 4604.00 | 0.00 | 0.00 |
| Minimum of Months | 10.87 | 4.93 | 5.94 | 12.77 | 1.76 | 230.67 | 0.00 | 0.00 |
| Maximum of Months | 20.03 | 8.70 | 12.24 | 37.58 | 21.46 | 511.50 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ENTRANCE DOOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 39.86 | 20.38 | 19.48 | 44.92 | 66.95 | 21.33 | 0.00 | 0.00 |
| February | 44.10 | 21.21 | 22.89 | 53.02 | 56.37 | 33.17 | 0.00 | 0.00 |
| March | 52.01 | 25.05 | 26.96 | 68.61 | 48.31 | 26.17 | 0.00 | 0.00 |
| April | 57.21 | 25.92 | 31.29 | 85.04 | 32.31 | 49.67 | 0.00 | 0.00 |
| May | 58.85 | 25.54 | 33.31 | 104.05 | 11.64 | 117.33 | 0.00 | 0.00 |
| June | 59.65 | 23.67 | 35.99 | 108.86 | 10.60 | 122.00 | 0.00 | 0.00 |
| July | 57.56 | 21.09 | 36.46 | 104.59 | 8.19 | 157.67 | 0.00 | 0.00 |
| August | 53.01 | 18.21 | 34.80 | 95.14 | 10.95 | 138.83 | 0.00 | 0.00 |
| September | 46.89 | 16.09 | 30.80 | 80.04 | 15.10 | 128.33 | 0.00 | 0.00 |
| October | 46.50 | 19.68 | 26.82 | 75.35 | 23.95 | 99.67 | 0.00 | 0.00 |
| November | 41.08 | 20.95 | 20.13 | 53.07 | 46.83 | 45.33 | 0.00 | 0.00 |
| December | 32.37 | 14.68 | 17.69 | 36.64 | 61.09 | 23.17 | 0.00 | 0.00 |
| Annual Sum or Average | 49.11 | 21.03 | 28.08 | 75.90 | 32.57 | 962.67 | 0.00 | 0.00 |
| Minimum of Months | 32.37 | 14.68 | 17.69 | 36.64 | 8.19 | 21.33 | 0.00 | 0.00 |
| Maximum of Months | 59.65 | 25.92 | 36.46 | 108.86 | 66.95 | 157.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW14
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 13.38 | 6.84 | 6.54 | 14.27 | 24.23 | 577.83 | 0.00 | 0.00 |
| February | 14.81 | 7.12 | 7.69 | 16.87 | 20.62 | 504.17 | 0.00 | 0.00 |
| March | 17.46 | 8.41 | 9.05 | 22.15 | 17.63 | 521.33 | 0.00 | 0.00 |
| April | 19.21 | 8.70 | 10.51 | 28.28 | 11.13 | 429.17 | 0.00 | 0.00 |
| May | 19.76 | 8.57 | 11.19 | 36.26 | 2.99 | 298.67 | 0.00 | 0.00 |
| June | 20.03 | 7.95 | 12.08 | 38.20 | 2.55 | 270.17 | 0.00 | 0.00 |
| July | 19.33 | 7.08 | 12.24 | 37.05 | 1.66 | 210.83 | 0.00 | 0.00 |
| August | 17.80 | 6.11 | 11.68 | 33.85 | 2.44 | 269.33 | 0.00 | 0.00 |
| September | 15.74 | 5.40 | 10.34 | 28.37 | 3.77 | 339.83 | 0.00 | 0.00 |
| October | 15.61 | 6.61 | 9.01 | 26.30 | 6.93 | 386.17 | 0.00 | 0.00 |
| November | 13.79 | 7.03 | 6.76 | 17.69 | 15.78 | 500.83 | 0.00 | 0.00 |
| December | 10.87 | 4.93 | 5.94 | 11.93 | 21.55 | 577.00 | 0.00 | 0.00 |
| Annual Sum or Average | 16.49 | 7.06 | 9.43 | 25.99 | 10.89 | 4885.33 | 0.00 | 0.00 |
| Minimum of Months | 10.87 | 4.93 | 5.94 | 11.93 | 1.66 | 210.83 | 0.00 | 0.00 |
| Maximum of Months | 20.03 | 8.70 | 12.24 | 38.20 | 24.23 | 577.83 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.502791E+09 | 0.357141E+09 | 0.145651E+09 | 0.727717E+09 | 0.351510E+09 |
| February | 0.418930E+09 | 0.272196E+09 | 0.146733E+09 | 0.621170E+09 | 0.267757E+09 |
| March | 0.290211E+09 | 0.128898E+09 | 0.161313E+09 | 0.443757E+09 | 0.257219E+09 |
| April | 0.215630E+09 | 54115104.10 | 0.161515E+09 | 0.366720E+09 | 0.155141E+09 |
| May | 0.167073E+09 | 7576796.02 | 0.159496E+09 | 0.366800E+09 | 30648582.33 |
| June | 0.159351E+09 | 1647151.60 | 0.157704E+09 | 0.360265E+09 | 24313096.48 |
| July | 0.172296E+09 | 3238841.76 | 0.169057E+09 | 0.391277E+09 | 13975959.64 |
| August | 0.200876E+09 | 22577599.97 | 0.178298E+09 | 0.447107E+09 | 27998582.06 |
| September | 0.238407E+09 | 65161043.25 | 0.173246E+09 | 0.484882E+09 | 46154777.70 |
| October | 0.370348E+09 | 0.189674E+09 | 0.180674E+09 | 0.689054E+09 | 97940347.14 |
| November | 0.466286E+09 | 0.321602E+09 | 0.144684E+09 | 0.734365E+09 | 0.223166E+09 |
| December | 0.495387E+09 | 0.355537E+09 | 0.139850E+09 | 0.746588E+09 | 0.311869E+09 |
| Annual Sum or Average | 0.369759E+10 | 0.177937E+10 | 0.191822E+10 | 0.637970E+10 | 0.180769E+10 |
| Minimum of Months | 0.159351E+09 | 1647151.60 | 0.139850E+09 | 0.360265E+09 | 13975959.64 |
| Maximum of Months | 0.502791E+09 | 0.357141E+09 | 0.180674E+09 | 0.746588E+09 | 0.351510E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 W SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.158021E+09 | 85347902.52 | 72672624.48 | 0.194850E+09 | 0.254961E+09 |
| February | 0.161517E+09 | 81636932.67 | 79880196.06 | 0.211054E+09 | 0.190243E+09 |
| March | 0.176571E+09 | 78127728.44 | 98442962.80 | 0.246210E+09 | 0.172560E+09 |
| April | 0.211931E+09 | 97331851.08 | 0.114599E+09 | 0.341576E+09 | 99402256.78 |
| May | 0.182433E+09 | 59372310.88 | 0.123060E+09 | 0.368264E+09 | 20260368.42 |
| June | 0.196297E+09 | 68993422.12 | 0.127304E+09 | 0.403488E+09 | 15850194.92 |
| July | 0.184820E+09 | 51210314.87 | 0.133609E+09 | 0.385350E+09 | 9395247.74 |
| August | 0.186866E+09 | 56979874.95 | 0.129886E+09 | 0.382462E+09 | 18198566.81 |
| September | 0.166720E+09 | 57241413.69 | 0.109478E+09 | 0.320636E+09 | 30139874.41 |
| October | 0.175921E+09 | 75844789.61 | 0.100076E+09 | 0.318846E+09 | 66158508.88 |
| November | 0.146163E+09 | 73426852.63 | 72735834.01 | 0.208273E+09 | 0.159652E+09 |
| December | 0.145317E+09 | 77267943.06 | 68048957.49 | 0.189525E+09 | 0.220438E+09 |
| Annual Sum or Average | 0.209258E+10 | 0.862781E+09 | 0.122979E+10 | 0.357053E+10 | 0.125726E+10 |
| Minimum of Months | 0.145317E+09 | 51210314.87 | 68048957.49 | 0.189525E+09 | 9395247.74 |
| Maximum of Months | 0.211931E+09 | 97331851.08 | 0.133609E+09 | 0.403488E+09 | 0.254961E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 W NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.158021E+09 | 85347902.52 | 72672624.48 | 0.205250E+09 | 0.236576E+09 |
| February | 0.161517E+09 | 81636932.67 | 79880196.06 | 0.220790E+09 | 0.176582E+09 |
| March | 0.176571E+09 | 78127728.44 | 98442962.80 | 0.252526E+09 | 0.165271E+09 |
| April | 0.211931E+09 | 97331851.08 | 0.114599E+09 | 0.344071E+09 | 97872153.25 |
| May | 0.182433E+09 | 59372310.88 | 0.123060E+09 | 0.368437E+09 | 20267394.56 |
| June | 0.196297E+09 | 68993422.12 | 0.127304E+09 | 0.403052E+09 | 16063617.42 |
| July | 0.184820E+09 | 51210314.87 | 0.133609E+09 | 0.385111E+09 | 9466451.11 |
| August | 0.186866E+09 | 56979874.95 | 0.129886E+09 | 0.383365E+09 | 17991815.43 |
| September | 0.166720E+09 | 57241413.69 | 0.109478E+09 | 0.322522E+09 | 29161514.96 |
| October | 0.175921E+09 | 75844789.61 | 0.100076E+09 | 0.322794E+09 | 63688172.61 |
| November | 0.146163E+09 | 73426852.63 | 72735834.01 | 0.214430E+09 | 0.153556E+09 |
| December | 0.145317E+09 | 77267943.06 | 68048957.49 | 0.197149E+09 | 0.208771E+09 |
| Annual Sum or Average | 0.209258E+10 | 0.862781E+09 | 0.122979E+10 | 0.361950E+10 | 0.119527E+10 |
| Minimum of Months | 0.145317E+09 | 51210314.87 | 68048957.49 | 0.197149E+09 | 9466451.11 |
| Maximum of Months | 0.211931E+09 | 97331851.08 | 0.133609E+09 | 0.403052E+09 | 0.236576E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 87851305.19 | 0.00 | 87851305.19 | 57517974.49 | 0.383466E+09 |
| February | 93613281.56 | 0.00 | 93613281.56 | 75827363.37 | 0.283402E+09 |
| March | 0.120260E+09 | 5622.98 | 0.120255E+09 | 0.125991E+09 | 0.261068E+09 |
| April | 0.137691E+09 | 814454.99 | 0.136876E+09 | 0.193689E+09 | 0.151210E+09 |
| May | 0.161025E+09 | 6063506.41 | 0.154962E+09 | 0.349866E+09 | 29403703.47 |
| June | 0.176659E+09 | 12028244.03 | 0.164631E+09 | 0.397196E+09 | 23189950.72 |
| July | 0.177281E+09 | 6616296.66 | 0.170665E+09 | 0.399407E+09 | 14197341.23 |
| August | 0.159426E+09 | 1641530.34 | 0.157785E+09 | 0.354776E+09 | 26619925.48 |
| September | 0.132846E+09 | 25838.56 | 0.132820E+09 | 0.269669E+09 | 44604840.82 |
| October | 0.119234E+09 | 0.00 | 0.119234E+09 | 0.219470E+09 | 98765885.55 |
| November | 87597669.79 | 0.00 | 87597669.79 | 86215296.54 | 0.243806E+09 |
| December | 81667786.01 | 0.00 | 81667786.01 | 60483195.15 | 0.337297E+09 |
| Annual Sum or Average | 0.153515E+10 | 27195493.98 | 0.150796E+10 | 0.259011E+10 | 0.189703E+10 |
| Minimum of Months | 81667786.01 | 0.00 | 81667786.01 | 57517974.49 | 14197341.23 |
| Maximum of Months | 0.177281E+09 | 12028244.03 | 0.170665E+09 | 0.399407E+09 | 0.383466E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.502791E+09 | 0.357141E+09 | 0.145651E+09 | 0.726349E+09 | 0.359830E+09 |
| February | 0.418930E+09 | 0.272196E+09 | 0.146733E+09 | 0.622993E+09 | 0.273355E+09 |
| March | 0.290211E+09 | 0.128898E+09 | 0.161313E+09 | 0.439791E+09 | 0.269212E+09 |
| April | 0.215630E+09 | 54115104.10 | 0.161515E+09 | 0.355124E+09 | 0.179907E+09 |
| May | 0.167073E+09 | 7576796.02 | 0.159496E+09 | 0.329682E+09 | 75638517.91 |
| June | 0.159351E+09 | 1647151.60 | 0.157704E+09 | 0.321825E+09 | 69226056.81 |
| July | 0.172296E+09 | 3238841.76 | 0.169057E+09 | 0.336510E+09 | 61336150.24 |
| August | 0.200876E+09 | 22577599.97 | 0.178298E+09 | 0.404613E+09 | 79546650.24 |
| September | 0.238407E+09 | 65161043.25 | 0.173246E+09 | 0.448237E+09 | 99732093.31 |
| October | 0.370348E+09 | 0.189674E+09 | 0.180674E+09 | 0.661016E+09 | 0.152534E+09 |
| November | 0.466286E+09 | 0.321602E+09 | 0.144684E+09 | 0.726074E+09 | 0.254453E+09 |
| December | 0.495387E+09 | 0.355537E+09 | 0.139850E+09 | 0.741993E+09 | 0.329978E+09 |
| Annual Sum or Average | 0.369759E+10 | 0.177937E+10 | 0.191822E+10 | 0.611421E+10 | 0.220475E+10 |
| Minimum of Months | 0.159351E+09 | 1647151.60 | 0.139850E+09 | 0.321825E+09 | 61336150.24 |
| Maximum of Months | 0.502791E+09 | 0.357141E+09 | 0.180674E+09 | 0.741993E+09 | 0.359830E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 E SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.149391E+09 | 76380900.21 | 73009938.99 | 0.169354E+09 | 0.251234E+09 |
| February | 0.149295E+09 | 71797887.95 | 77497036.91 | 0.184551E+09 | 0.186139E+09 |
| March | 0.194919E+09 | 93866035.49 | 0.101053E+09 | 0.266471E+09 | 0.172576E+09 |
| April | 0.207495E+09 | 93994691.47 | 0.113500E+09 | 0.321847E+09 | 0.112096E+09 |
| May | 0.220559E+09 | 95705537.34 | 0.124853E+09 | 0.406731E+09 | 47452590.00 |
| June | 0.216360E+09 | 85835864.82 | 0.130524E+09 | 0.411600E+09 | 43174661.36 |
| July | 0.215710E+09 | 79049917.79 | 0.136660E+09 | 0.403843E+09 | 38933808.72 |
| August | 0.198680E+09 | 68252399.00 | 0.130428E+09 | 0.370872E+09 | 50050363.04 |
| September | 0.170060E+09 | 58356923.99 | 0.111703E+09 | 0.299366E+09 | 64052232.12 |
| October | 0.174276E+09 | 73745867.93 | 0.100530E+09 | 0.291407E+09 | 0.100301E+09 |
| November | 0.148984E+09 | 75969936.22 | 73014387.14 | 0.197446E+09 | 0.173278E+09 |
| December | 0.121301E+09 | 55018271.94 | 66283178.64 | 0.139883E+09 | 0.230043E+09 |
| Annual Sum or Average | 0.216703E+10 | 0.927974E+09 | 0.123906E+10 | 0.346337E+10 | 0.146933E+10 |
| Minimum of Months | 0.121301E+09 | 55018271.94 | 66283178.64 | 0.139883E+09 | 38933808.72 |
| Maximum of Months | 0.220559E+09 | 95705537.34 | 0.136660E+09 | 0.411600E+09 | 0.251234E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 E NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.149391E+09 | 76380900.21 | 73009938.99 | 0.178982E+09 | 0.226044E+09 |
| February | 0.149295E+09 | 71797887.95 | 77497036.91 | 0.191746E+09 | 0.167918E+09 |
| March | 0.194919E+09 | 93866035.49 | 0.101053E+09 | 0.273610E+09 | 0.157013E+09 |
| April | 0.207495E+09 | 93994691.47 | 0.113500E+09 | 0.330960E+09 | 94026534.23 |
| May | 0.220559E+09 | 95705537.34 | 0.124853E+09 | 0.432265E+09 | 18939691.58 |
| June | 0.216360E+09 | 85835864.82 | 0.130524E+09 | 0.437697E+09 | 14915521.75 |
| July | 0.215710E+09 | 79049917.79 | 0.136660E+09 | 0.440120E+09 | 8890610.45 |
| August | 0.198680E+09 | 68252399.00 | 0.130428E+09 | 0.400897E+09 | 16891538.05 |
| September | 0.170060E+09 | 58356923.99 | 0.111703E+09 | 0.325985E+09 | 27980059.54 |
| October | 0.174276E+09 | 73745867.93 | 0.100530E+09 | 0.313502E+09 | 60370524.45 |
| November | 0.148984E+09 | 75969936.22 | 73014387.14 | 0.207279E+09 | 0.144699E+09 |
| December | 0.121301E+09 | 55018271.94 | 66283178.64 | 0.149017E+09 | 0.203610E+09 |
| Annual Sum or Average | 0.216703E+10 | 0.927974E+09 | 0.123906E+10 | 0.368206E+10 | 0.114130E+10 |
| Minimum of Months | 0.121301E+09 | 55018271.94 | 66283178.64 | 0.149017E+09 | 8890610.45 |
| Maximum of Months | 0.220559E+09 | 95705537.34 | 0.136660E+09 | 0.440120E+09 | 0.226044E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 87851305.19 | 0.00 | 87851305.19 | 56479144.70 | 0.382648E+09 |
| February | 93613281.56 | 0.00 | 93613281.56 | 74703034.72 | 0.282542E+09 |
| March | 0.120260E+09 | 5622.98 | 0.120255E+09 | 0.123953E+09 | 0.260805E+09 |
| April | 0.137691E+09 | 814454.99 | 0.136876E+09 | 0.192075E+09 | 0.150176E+09 |
| May | 0.161025E+09 | 6063506.41 | 0.154962E+09 | 0.348528E+09 | 29313169.18 |
| June | 0.176659E+09 | 12028244.03 | 0.164631E+09 | 0.396256E+09 | 22979237.94 |
| July | 0.177281E+09 | 6616296.66 | 0.170665E+09 | 0.398310E+09 | 14187608.17 |
| August | 0.159426E+09 | 1641530.34 | 0.157785E+09 | 0.354229E+09 | 26312099.82 |
| September | 0.132846E+09 | 25838.56 | 0.132820E+09 | 0.269266E+09 | 44187716.81 |
| October | 0.119234E+09 | 0.00 | 0.119234E+09 | 0.218834E+09 | 97752122.67 |
| November | 87597669.79 | 0.00 | 87597669.79 | 85031483.25 | 0.242900E+09 |
| December | 81667786.01 | 0.00 | 81667786.01 | 60234259.65 | 0.334934E+09 |
| Annual Sum or Average | 0.153515E+10 | 27195493.98 | 0.150796E+10 | 0.257790E+10 | 0.188874E+10 |
| Minimum of Months | 81667786.01 | 0.00 | 81667786.01 | 56479144.70 | 14187608.17 |
| Maximum of Months | 0.177281E+09 | 12028244.03 | 0.170665E+09 | 0.398310E+09 | 0.382648E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N N1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 87851305.19 | 0.00 | 87851305.19 | 55575001.75 | 0.395926E+09 |
| February | 93613281.56 | 0.00 | 93613281.56 | 73764080.35 | 0.293695E+09 |
| March | 0.120260E+09 | 5622.98 | 0.120255E+09 | 0.123668E+09 | 0.270141E+09 |
| April | 0.137691E+09 | 814454.99 | 0.136876E+09 | 0.193677E+09 | 0.152408E+09 |
| May | 0.161025E+09 | 6063506.41 | 0.154962E+09 | 0.352343E+09 | 28829119.31 |
| June | 0.176659E+09 | 12028244.03 | 0.164631E+09 | 0.400780E+09 | 22323626.84 |
| July | 0.177281E+09 | 6616296.66 | 0.170665E+09 | 0.404102E+09 | 13325998.54 |
| August | 0.159426E+09 | 1641530.34 | 0.157785E+09 | 0.360040E+09 | 24661024.80 |
| September | 0.132846E+09 | 25838.56 | 0.132820E+09 | 0.273782E+09 | 42242122.92 |
| October | 0.119234E+09 | 0.00 | 0.119234E+09 | 0.223069E+09 | 96339235.55 |
| November | 87597669.79 | 0.00 | 87597669.79 | 86913228.58 | 0.243436E+09 |
| December | 81667786.01 | 0.00 | 81667786.01 | 59977560.20 | 0.343669E+09 |
| Annual Sum or Average | 0.153515E+10 | 27195493.98 | 0.150796E+10 | 0.260769E+10 | 0.192700E+10 |
| Minimum of Months | 81667786.01 | 0.00 | 81667786.01 | 55575001.75 | 13325998.54 |
| Maximum of Months | 0.177281E+09 | 12028244.03 | 0.170665E+09 | 0.404102E+09 | 0.395926E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N N2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 87851305.19 | 0.00 | 87851305.19 | 55525991.82 | 0.395961E+09 |
| February | 93613281.56 | 0.00 | 93613281.56 | 73705686.65 | 0.293704E+09 |
| March | 0.120260E+09 | 5622.98 | 0.120255E+09 | 0.123546E+09 | 0.270206E+09 |
| April | 0.137691E+09 | 814454.99 | 0.136876E+09 | 0.193591E+09 | 0.152401E+09 |
| May | 0.161025E+09 | 6063506.41 | 0.154962E+09 | 0.352287E+09 | 28835945.43 |
| June | 0.176659E+09 | 12028244.03 | 0.164631E+09 | 0.400743E+09 | 22321496.60 |
| July | 0.177281E+09 | 6616296.66 | 0.170665E+09 | 0.404053E+09 | 13330671.78 |
| August | 0.159426E+09 | 1641530.34 | 0.157785E+09 | 0.360019E+09 | 24650619.40 |
| September | 0.132846E+09 | 25838.56 | 0.132820E+09 | 0.273769E+09 | 42227322.26 |
| October | 0.119234E+09 | 0.00 | 0.119234E+09 | 0.223050E+09 | 96287100.74 |
| November | 87597669.79 | 0.00 | 87597669.79 | 86857538.28 | 0.243425E+09 |
| December | 81667786.01 | 0.00 | 81667786.01 | 59990660.84 | 0.343498E+09 |
| Annual Sum or Average | 0.153515E+10 | 27195493.98 | 0.150796E+10 | 0.260714E+10 | 0.192685E+10 |
| Minimum of Months | 81667786.01 | 0.00 | 81667786.01 | 55525991.82 | 13330671.78 |
| Maximum of Months | 0.177281E+09 | 12028244.03 | 0.170665E+09 | 0.404053E+09 | 0.395961E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S S1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.502791E+09 | 0.357141E+09 | 0.145651E+09 | 0.725140E+09 | 0.357143E+09 |
| February | 0.418930E+09 | 0.272196E+09 | 0.146733E+09 | 0.618193E+09 | 0.273454E+09 |
| March | 0.290211E+09 | 0.128898E+09 | 0.161313E+09 | 0.440837E+09 | 0.264884E+09 |
| April | 0.215630E+09 | 54115104.10 | 0.161515E+09 | 0.366387E+09 | 0.156662E+09 |
| May | 0.167073E+09 | 7576796.02 | 0.159496E+09 | 0.369167E+09 | 30171345.78 |
| June | 0.159351E+09 | 1647151.60 | 0.157704E+09 | 0.363729E+09 | 23462162.74 |
| July | 0.172296E+09 | 3238841.76 | 0.169057E+09 | 0.395912E+09 | 13134230.75 |
| August | 0.200876E+09 | 22577599.97 | 0.178298E+09 | 0.452138E+09 | 26110707.25 |
| September | 0.238407E+09 | 65161043.25 | 0.173246E+09 | 0.488613E+09 | 43984652.08 |
| October | 0.370348E+09 | 0.189674E+09 | 0.180674E+09 | 0.692005E+09 | 96274305.92 |
| November | 0.466286E+09 | 0.321602E+09 | 0.144684E+09 | 0.734369E+09 | 0.223974E+09 |
| December | 0.495387E+09 | 0.355537E+09 | 0.139850E+09 | 0.745331E+09 | 0.315560E+09 |
| Annual Sum or Average | 0.369759E+10 | 0.177937E+10 | 0.191822E+10 | 0.639182E+10 | 0.182481E+10 |
| Minimum of Months | 0.159351E+09 | 1647151.60 | 0.139850E+09 | 0.363729E+09 | 13134230.75 |
| Maximum of Months | 0.502791E+09 | 0.357141E+09 | 0.180674E+09 | 0.745331E+09 | 0.357143E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S S2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.502791E+09 | 0.357141E+09 | 0.145651E+09 | 0.724919E+09 | 0.357376E+09 |
| February | 0.418930E+09 | 0.272196E+09 | 0.146733E+09 | 0.618177E+09 | 0.273370E+09 |
| March | 0.290211E+09 | 0.128898E+09 | 0.161313E+09 | 0.440431E+09 | 0.265280E+09 |
| April | 0.215630E+09 | 54115104.10 | 0.161515E+09 | 0.365396E+09 | 0.157782E+09 |
| May | 0.167073E+09 | 7576796.02 | 0.159496E+09 | 0.366959E+09 | 31761581.03 |
| June | 0.159351E+09 | 1647151.60 | 0.157704E+09 | 0.361453E+09 | 24903939.13 |
| July | 0.172296E+09 | 3238841.76 | 0.169057E+09 | 0.392863E+09 | 14310865.42 |
| August | 0.200876E+09 | 22577599.97 | 0.178298E+09 | 0.449679E+09 | 27699955.85 |
| September | 0.238407E+09 | 65161043.25 | 0.173246E+09 | 0.486663E+09 | 45991964.64 |
| October | 0.370348E+09 | 0.189674E+09 | 0.180674E+09 | 0.690222E+09 | 98382380.92 |
| November | 0.466286E+09 | 0.321602E+09 | 0.144684E+09 | 0.733474E+09 | 0.225218E+09 |
| December | 0.495387E+09 | 0.355537E+09 | 0.139850E+09 | 0.744857E+09 | 0.316221E+09 |
| Annual Sum or Average | 0.369759E+10 | 0.177937E+10 | 0.191822E+10 | 0.637509E+10 | 0.183830E+10 |
| Minimum of Months | 0.159351E+09 | 1647151.60 | 0.139850E+09 | 0.361453E+09 | 14310865.42 |
| Maximum of Months | 0.502791E+09 | 0.357141E+09 | 0.180674E+09 | 0.744857E+09 | 0.357376E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.502791E+09 | 0.357141E+09 | 0.145651E+09 | 0.721215E+09 | 0.354523E+09 |
| February | 0.418930E+09 | 0.272196E+09 | 0.146733E+09 | 0.611720E+09 | 0.276241E+09 |
| March | 0.290211E+09 | 0.128898E+09 | 0.161313E+09 | 0.432403E+09 | 0.271277E+09 |
| April | 0.215630E+09 | 54115104.10 | 0.161515E+09 | 0.357595E+09 | 0.164415E+09 |
| May | 0.167073E+09 | 7576796.02 | 0.159496E+09 | 0.363963E+09 | 31643024.87 |
| June | 0.159351E+09 | 1647151.60 | 0.157704E+09 | 0.359223E+09 | 24346037.86 |
| July | 0.172296E+09 | 3238841.76 | 0.169057E+09 | 0.393356E+09 | 12815615.43 |
| August | 0.200876E+09 | 22577599.97 | 0.178298E+09 | 0.451673E+09 | 24455781.38 |
| September | 0.238407E+09 | 65161043.25 | 0.173246E+09 | 0.488082E+09 | 41167118.49 |
| October | 0.370348E+09 | 0.189674E+09 | 0.180674E+09 | 0.690846E+09 | 92849090.25 |
| November | 0.466286E+09 | 0.321602E+09 | 0.144684E+09 | 0.732523E+09 | 0.220916E+09 |
| December | 0.495387E+09 | 0.355537E+09 | 0.139850E+09 | 0.743010E+09 | 0.311344E+09 |
| Annual Sum or Average | 0.369759E+10 | 0.177937E+10 | 0.191822E+10 | 0.634561E+10 | 0.182599E+10 |
| Minimum of Months | 0.159351E+09 | 1647151.60 | 0.139850E+09 | 0.357595E+09 | 12815615.43 |
| Maximum of Months | 0.502791E+09 | 0.357141E+09 | 0.180674E+09 | 0.743010E+09 | 0.354523E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 W SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.158021E+09 | 85347902.52 | 72672624.48 | 0.191834E+09 | 0.257636E+09 |
| February | 0.161517E+09 | 81636932.67 | 79880196.06 | 0.206146E+09 | 0.196735E+09 |
| March | 0.176571E+09 | 78127728.44 | 98442962.80 | 0.238997E+09 | 0.182163E+09 |
| April | 0.211931E+09 | 97331851.08 | 0.114599E+09 | 0.334738E+09 | 0.105254E+09 |
| May | 0.182433E+09 | 59372310.88 | 0.123060E+09 | 0.366012E+09 | 20979379.66 |
| June | 0.196297E+09 | 68993422.12 | 0.127304E+09 | 0.402166E+09 | 15897774.61 |
| July | 0.184820E+09 | 51210314.87 | 0.133609E+09 | 0.386084E+09 | 8684702.47 |
| August | 0.186866E+09 | 56979874.95 | 0.129886E+09 | 0.385173E+09 | 15915795.87 |
| September | 0.166720E+09 | 57241413.69 | 0.109478E+09 | 0.322882E+09 | 26983635.71 |
| October | 0.175921E+09 | 75844789.61 | 0.100076E+09 | 0.320657E+09 | 62803703.86 |
| November | 0.146163E+09 | 73426852.63 | 72735834.01 | 0.207882E+09 | 0.158198E+09 |
| December | 0.145317E+09 | 77267943.06 | 68048957.49 | 0.188152E+09 | 0.220441E+09 |
| Annual Sum or Average | 0.209258E+10 | 0.862781E+09 | 0.122979E+10 | 0.355073E+10 | 0.127169E+10 |
| Minimum of Months | 0.145317E+09 | 51210314.87 | 68048957.49 | 0.188152E+09 | 8684702.47 |
| Maximum of Months | 0.211931E+09 | 97331851.08 | 0.133609E+09 | 0.402166E+09 | 0.257636E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 W NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.158021E+09 | 85347902.52 | 72672624.48 | 0.201925E+09 | 0.241736E+09 |
| February | 0.161517E+09 | 81636932.67 | 79880196.06 | 0.213994E+09 | 0.187482E+09 |
| March | 0.176571E+09 | 78127728.44 | 98442962.80 | 0.243819E+09 | 0.177824E+09 |
| April | 0.211931E+09 | 97331851.08 | 0.114599E+09 | 0.336679E+09 | 0.104558E+09 |
| May | 0.182433E+09 | 59372310.88 | 0.123060E+09 | 0.366178E+09 | 20978934.40 |
| June | 0.196297E+09 | 68993422.12 | 0.127304E+09 | 0.401827E+09 | 16025962.56 |
| July | 0.184820E+09 | 51210314.87 | 0.133609E+09 | 0.385938E+09 | 8716389.86 |
| August | 0.186866E+09 | 56979874.95 | 0.129886E+09 | 0.386048E+09 | 15743226.99 |
| September | 0.166720E+09 | 57241413.69 | 0.109478E+09 | 0.324711E+09 | 26206957.49 |
| October | 0.175921E+09 | 75844789.61 | 0.100076E+09 | 0.324722E+09 | 60642882.00 |
| November | 0.146163E+09 | 73426852.63 | 72735834.01 | 0.214527E+09 | 0.152593E+09 |
| December | 0.145317E+09 | 77267943.06 | 68048957.49 | 0.196500E+09 | 0.208685E+09 |
| Annual Sum or Average | 0.209258E+10 | 0.862781E+09 | 0.122979E+10 | 0.359687E+10 | 0.122119E+10 |
| Minimum of Months | 0.145317E+09 | 51210314.87 | 68048957.49 | 0.196500E+09 | 8716389.86 |
| Maximum of Months | 0.211931E+09 | 97331851.08 | 0.133609E+09 | 0.401827E+09 | 0.241736E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 87851305.19 | 0.00 | 87851305.19 | 54997930.02 | 0.392140E+09 |
| February | 93613281.56 | 0.00 | 93613281.56 | 69211912.35 | 0.301649E+09 |
| March | 0.120260E+09 | 5622.98 | 0.120255E+09 | 0.116030E+09 | 0.281651E+09 |
| April | 0.137691E+09 | 814454.99 | 0.136876E+09 | 0.184983E+09 | 0.162069E+09 |
| May | 0.161025E+09 | 6063506.41 | 0.154962E+09 | 0.347076E+09 | 30284394.58 |
| June | 0.176659E+09 | 12028244.03 | 0.164631E+09 | 0.396185E+09 | 23005131.23 |
| July | 0.177281E+09 | 6616296.66 | 0.170665E+09 | 0.401394E+09 | 13018450.81 |
| August | 0.159426E+09 | 1641530.34 | 0.157785E+09 | 0.359969E+09 | 23103981.89 |
| September | 0.132846E+09 | 25838.56 | 0.132820E+09 | 0.274022E+09 | 39909081.81 |
| October | 0.119234E+09 | 0.00 | 0.119234E+09 | 0.223613E+09 | 93764718.48 |
| November | 87597669.79 | 0.00 | 87597669.79 | 87427051.24 | 0.242165E+09 |
| December | 81667786.01 | 0.00 | 81667786.01 | 60821325.02 | 0.337174E+09 |
| Annual Sum or Average | 0.153515E+10 | 27195493.98 | 0.150796E+10 | 0.257573E+10 | 0.193993E+10 |
| Minimum of Months | 81667786.01 | 0.00 | 81667786.01 | 54997930.02 | 13018450.81 |
| Maximum of Months | 0.177281E+09 | 12028244.03 | 0.170665E+09 | 0.401394E+09 | 0.392140E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.502791E+09 | 0.357141E+09 | 0.145651E+09 | 0.719794E+09 | 0.353461E+09 |
| February | 0.418930E+09 | 0.272196E+09 | 0.146733E+09 | 0.610326E+09 | 0.274930E+09 |
| March | 0.290211E+09 | 0.128898E+09 | 0.161313E+09 | 0.429791E+09 | 0.270735E+09 |
| April | 0.215630E+09 | 54115104.10 | 0.161515E+09 | 0.355360E+09 | 0.163513E+09 |
| May | 0.167073E+09 | 7576796.02 | 0.159496E+09 | 0.362666E+09 | 31438238.86 |
| June | 0.159351E+09 | 1647151.60 | 0.157704E+09 | 0.358261E+09 | 24055791.67 |
| July | 0.172296E+09 | 3238841.76 | 0.169057E+09 | 0.392323E+09 | 12707727.40 |
| August | 0.200876E+09 | 22577599.97 | 0.178298E+09 | 0.451119E+09 | 24099618.81 |
| September | 0.238407E+09 | 65161043.25 | 0.173246E+09 | 0.487630E+09 | 40697375.95 |
| October | 0.370348E+09 | 0.189674E+09 | 0.180674E+09 | 0.690102E+09 | 92061601.45 |
| November | 0.466286E+09 | 0.321602E+09 | 0.144684E+09 | 0.731012E+09 | 0.220121E+09 |
| December | 0.495387E+09 | 0.355537E+09 | 0.139850E+09 | 0.742491E+09 | 0.309746E+09 |
| Annual Sum or Average | 0.369759E+10 | 0.177937E+10 | 0.191822E+10 | 0.633088E+10 | 0.181757E+10 |
| Minimum of Months | 0.159351E+09 | 1647151.60 | 0.139850E+09 | 0.355360E+09 | 12707727.40 |
| Maximum of Months | 0.502791E+09 | 0.357141E+09 | 0.180674E+09 | 0.742491E+09 | 0.353461E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 E SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.149391E+09 | 76380900.21 | 73009938.99 | 0.166682E+09 | 0.247979E+09 |
| February | 0.149295E+09 | 71797887.95 | 77497036.91 | 0.178045E+09 | 0.188180E+09 |
| March | 0.194919E+09 | 93866035.49 | 0.101053E+09 | 0.259524E+09 | 0.173415E+09 |
| April | 0.207495E+09 | 93994691.47 | 0.113500E+09 | 0.321331E+09 | 0.101401E+09 |
| May | 0.220559E+09 | 95705537.34 | 0.124853E+09 | 0.429274E+09 | 19408946.59 |
| June | 0.216360E+09 | 85835864.82 | 0.130524E+09 | 0.436637E+09 | 14634688.23 |
| July | 0.215710E+09 | 79049917.79 | 0.136660E+09 | 0.440987E+09 | 8006795.52 |
| August | 0.198680E+09 | 68252399.00 | 0.130428E+09 | 0.402699E+09 | 14815833.73 |
| September | 0.170060E+09 | 58356923.99 | 0.111703E+09 | 0.326357E+09 | 25756357.52 |
| October | 0.174276E+09 | 73745867.93 | 0.100530E+09 | 0.311185E+09 | 59687612.37 |
| November | 0.148984E+09 | 75969936.22 | 73014387.14 | 0.200989E+09 | 0.150088E+09 |
| December | 0.121301E+09 | 55018271.94 | 66283178.64 | 0.140866E+09 | 0.216707E+09 |
| Annual Sum or Average | 0.216703E+10 | 0.927974E+09 | 0.123906E+10 | 0.361457E+10 | 0.122008E+10 |
| Minimum of Months | 0.121301E+09 | 55018271.94 | 66283178.64 | 0.140866E+09 | 8006795.52 |
| Maximum of Months | 0.220559E+09 | 95705537.34 | 0.136660E+09 | 0.440987E+09 | 0.247979E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 E NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.149391E+09 | 76380900.21 | 73009938.99 | 0.175545E+09 | 0.231115E+09 |
| February | 0.149295E+09 | 71797887.95 | 77497036.91 | 0.185066E+09 | 0.178106E+09 |
| March | 0.194919E+09 | 93866035.49 | 0.101053E+09 | 0.264150E+09 | 0.168651E+09 |
| April | 0.207495E+09 | 93994691.47 | 0.113500E+09 | 0.323137E+09 | 0.100632E+09 |
| May | 0.220559E+09 | 95705537.34 | 0.124853E+09 | 0.429446E+09 | 19399064.12 |
| June | 0.216360E+09 | 85835864.82 | 0.130524E+09 | 0.436304E+09 | 14752002.71 |
| July | 0.215710E+09 | 79049917.79 | 0.136660E+09 | 0.440843E+09 | 8037644.69 |
| August | 0.198680E+09 | 68252399.00 | 0.130428E+09 | 0.403582E+09 | 14649596.01 |
| September | 0.170060E+09 | 58356923.99 | 0.111703E+09 | 0.328194E+09 | 24979940.21 |
| October | 0.174276E+09 | 73745867.93 | 0.100530E+09 | 0.315309E+09 | 57250896.43 |
| November | 0.148984E+09 | 75969936.22 | 73014387.14 | 0.207163E+09 | 0.143565E+09 |
| December | 0.121301E+09 | 55018271.94 | 66283178.64 | 0.148378E+09 | 0.203490E+09 |
| Annual Sum or Average | 0.216703E+10 | 0.927974E+09 | 0.123906E+10 | 0.365712E+10 | 0.116463E+10 |
| Minimum of Months | 0.121301E+09 | 55018271.94 | 66283178.64 | 0.148378E+09 | 8037644.69 |
| Maximum of Months | 0.220559E+09 | 95705537.34 | 0.136660E+09 | 0.440843E+09 | 0.231115E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 87851305.19 | 0.00 | 87851305.19 | 53655247.62 | 0.391324E+09 |
| February | 93613281.56 | 0.00 | 93613281.56 | 67913870.62 | 0.300245E+09 |
| March | 0.120260E+09 | 5622.98 | 0.120255E+09 | 0.113703E+09 | 0.280902E+09 |
| April | 0.137691E+09 | 814454.99 | 0.136876E+09 | 0.182732E+09 | 0.161183E+09 |
| May | 0.161025E+09 | 6063506.41 | 0.154962E+09 | 0.345797E+09 | 30055735.39 |
| June | 0.176659E+09 | 12028244.03 | 0.164631E+09 | 0.395261E+09 | 22723358.98 |
| July | 0.177281E+09 | 6616296.66 | 0.170665E+09 | 0.400401E+09 | 12922047.80 |
| August | 0.159426E+09 | 1641530.34 | 0.157785E+09 | 0.359415E+09 | 22753100.62 |
| September | 0.132846E+09 | 25838.56 | 0.132820E+09 | 0.273555E+09 | 39458727.40 |
| October | 0.119234E+09 | 0.00 | 0.119234E+09 | 0.222803E+09 | 92648516.94 |
| November | 87597669.79 | 0.00 | 87597669.79 | 85990854.34 | 0.240839E+09 |
| December | 81667786.01 | 0.00 | 81667786.01 | 60382914.09 | 0.334724E+09 |
| Annual Sum or Average | 0.153515E+10 | 27195493.98 | 0.150796E+10 | 0.256161E+10 | 0.192978E+10 |
| Minimum of Months | 81667786.01 | 0.00 | 81667786.01 | 53655247.62 | 12922047.80 |
| Maximum of Months | 0.177281E+09 | 12028244.03 | 0.170665E+09 | 0.400401E+09 | 0.391324E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N N1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 87851305.19 | 0.00 | 87851305.19 | 52820459.77 | 0.406458E+09 |
| February | 93613281.56 | 0.00 | 93613281.56 | 68403135.82 | 0.308442E+09 |
| March | 0.120260E+09 | 5622.98 | 0.120255E+09 | 0.115995E+09 | 0.285898E+09 |
| April | 0.137691E+09 | 814454.99 | 0.136876E+09 | 0.187378E+09 | 0.159958E+09 |
| May | 0.161025E+09 | 6063506.41 | 0.154962E+09 | 0.351259E+09 | 28808499.23 |
| June | 0.176659E+09 | 12028244.03 | 0.164631E+09 | 0.401013E+09 | 21621013.38 |
| July | 0.177281E+09 | 6616296.66 | 0.170665E+09 | 0.406677E+09 | 12095008.06 |
| August | 0.159426E+09 | 1641530.34 | 0.157785E+09 | 0.364750E+09 | 21704040.21 |
| September | 0.132846E+09 | 25838.56 | 0.132820E+09 | 0.277656E+09 | 38287667.56 |
| October | 0.119234E+09 | 0.00 | 0.119234E+09 | 0.226690E+09 | 92181732.14 |
| November | 87597669.79 | 0.00 | 87597669.79 | 87740638.12 | 0.242508E+09 |
| December | 81667786.01 | 0.00 | 81667786.01 | 59804461.88 | 0.346318E+09 |
| Annual Sum or Average | 0.153515E+10 | 27195493.98 | 0.150796E+10 | 0.260019E+10 | 0.196428E+10 |
| Minimum of Months | 81667786.01 | 0.00 | 81667786.01 | 52820459.77 | 12095008.06 |
| Maximum of Months | 0.177281E+09 | 12028244.03 | 0.170665E+09 | 0.406677E+09 | 0.406458E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N N2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 87851305.19 | 0.00 | 87851305.19 | 52754870.69 | 0.406526E+09 |
| February | 93613281.56 | 0.00 | 93613281.56 | 68345712.65 | 0.308402E+09 |
| March | 0.120260E+09 | 5622.98 | 0.120255E+09 | 0.115866E+09 | 0.285940E+09 |
| April | 0.137691E+09 | 814454.99 | 0.136876E+09 | 0.187255E+09 | 0.159973E+09 |
| May | 0.161025E+09 | 6063506.41 | 0.154962E+09 | 0.351214E+09 | 28806464.78 |
| June | 0.176659E+09 | 12028244.03 | 0.164631E+09 | 0.400979E+09 | 21614137.51 |
| July | 0.177281E+09 | 6616296.66 | 0.170665E+09 | 0.406639E+09 | 12094032.55 |
| August | 0.159426E+09 | 1641530.34 | 0.157785E+09 | 0.364730E+09 | 21691898.38 |
| September | 0.132846E+09 | 25838.56 | 0.132820E+09 | 0.277640E+09 | 38271423.41 |
| October | 0.119234E+09 | 0.00 | 0.119234E+09 | 0.226663E+09 | 92131541.14 |
| November | 87597669.79 | 0.00 | 87597669.79 | 87669234.40 | 0.242485E+09 |
| December | 81667786.01 | 0.00 | 81667786.01 | 59807491.99 | 0.346138E+09 |
| Annual Sum or Average | 0.153515E+10 | 27195493.98 | 0.150796E+10 | 0.259956E+10 | 0.196407E+10 |
| Minimum of Months | 81667786.01 | 0.00 | 81667786.01 | 52754870.69 | 12094032.55 |
| Maximum of Months | 0.177281E+09 | 12028244.03 | 0.170665E+09 | 0.406639E+09 | 0.406526E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S S1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.502791E+09 | 0.357141E+09 | 0.145651E+09 | 0.718757E+09 | 0.360042E+09 |
| February | 0.418930E+09 | 0.272196E+09 | 0.146733E+09 | 0.610347E+09 | 0.279672E+09 |
| March | 0.290211E+09 | 0.128898E+09 | 0.161313E+09 | 0.432150E+09 | 0.274535E+09 |
| April | 0.215630E+09 | 54115104.10 | 0.161515E+09 | 0.359592E+09 | 0.163060E+09 |
| May | 0.167073E+09 | 7576796.02 | 0.159496E+09 | 0.368106E+09 | 30128460.96 |
| June | 0.159351E+09 | 1647151.60 | 0.157704E+09 | 0.363993E+09 | 22879410.89 |
| July | 0.172296E+09 | 3238841.76 | 0.169057E+09 | 0.398713E+09 | 11858853.35 |
| August | 0.200876E+09 | 22577599.97 | 0.178298E+09 | 0.456350E+09 | 23056483.48 |
| September | 0.238407E+09 | 65161043.25 | 0.173246E+09 | 0.491486E+09 | 39625493.59 |
| October | 0.370348E+09 | 0.189674E+09 | 0.180674E+09 | 0.693430E+09 | 91850708.94 |
| November | 0.466286E+09 | 0.321602E+09 | 0.144684E+09 | 0.732363E+09 | 0.222098E+09 |
| December | 0.495387E+09 | 0.355537E+09 | 0.139850E+09 | 0.741555E+09 | 0.315639E+09 |
| Annual Sum or Average | 0.369759E+10 | 0.177937E+10 | 0.191822E+10 | 0.636684E+10 | 0.183445E+10 |
| Minimum of Months | 0.159351E+09 | 1647151.60 | 0.139850E+09 | 0.359592E+09 | 11858853.35 |
| Maximum of Months | 0.502791E+09 | 0.357141E+09 | 0.180674E+09 | 0.741555E+09 | 0.360042E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S S2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.502791E+09 | 0.357141E+09 | 0.145651E+09 | 0.718689E+09 | 0.360019E+09 |
| February | 0.418930E+09 | 0.272196E+09 | 0.146733E+09 | 0.610295E+09 | 0.279624E+09 |
| March | 0.290211E+09 | 0.128898E+09 | 0.161313E+09 | 0.432028E+09 | 0.274549E+09 |
| April | 0.215630E+09 | 54115104.10 | 0.161515E+09 | 0.359475E+09 | 0.163055E+09 |
| May | 0.167073E+09 | 7576796.02 | 0.159496E+09 | 0.368060E+09 | 30126402.77 |
| June | 0.159351E+09 | 1647151.60 | 0.157704E+09 | 0.363959E+09 | 22871996.59 |
| July | 0.172296E+09 | 3238841.76 | 0.169057E+09 | 0.398674E+09 | 11857513.81 |
| August | 0.200876E+09 | 22577599.97 | 0.178298E+09 | 0.456331E+09 | 23044001.44 |
| September | 0.238407E+09 | 65161043.25 | 0.173246E+09 | 0.491474E+09 | 39608719.16 |
| October | 0.370348E+09 | 0.189674E+09 | 0.180674E+09 | 0.693406E+09 | 91821582.51 |
| November | 0.466286E+09 | 0.321602E+09 | 0.144684E+09 | 0.732299E+09 | 0.222089E+09 |
| December | 0.495387E+09 | 0.355537E+09 | 0.139850E+09 | 0.741544E+09 | 0.315556E+09 |
| Annual Sum or Average | 0.369759E+10 | 0.177937E+10 | 0.191822E+10 | 0.636623E+10 | 0.183422E+10 |
| Minimum of Months | 0.159351E+09 | 1647151.60 | 0.139850E+09 | 0.359475E+09 | 11857513.81 |
| Maximum of Months | 0.502791E+09 | 0.357141E+09 | 0.180674E+09 | 0.741544E+09 | 0.360019E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.502791E+09 | 0.357141E+09 | 0.145651E+09 | 0.729342E+09 | 0.321022E+09 |
| February | 0.418930E+09 | 0.272196E+09 | 0.146733E+09 | 0.614731E+09 | 0.255034E+09 |
| March | 0.290211E+09 | 0.128898E+09 | 0.161313E+09 | 0.434135E+09 | 0.248730E+09 |
| April | 0.215630E+09 | 54115104.10 | 0.161515E+09 | 0.352015E+09 | 0.159228E+09 |
| May | 0.167073E+09 | 7576796.02 | 0.159496E+09 | 0.353801E+09 | 31294830.16 |
| June | 0.159351E+09 | 1647151.60 | 0.157704E+09 | 0.348421E+09 | 24170409.12 |
| July | 0.172296E+09 | 3238841.76 | 0.169057E+09 | 0.381665E+09 | 12803638.65 |
| August | 0.200876E+09 | 22577599.97 | 0.178298E+09 | 0.440357E+09 | 24368256.17 |
| September | 0.238407E+09 | 65161043.25 | 0.173246E+09 | 0.478546E+09 | 41067592.34 |
| October | 0.370348E+09 | 0.189674E+09 | 0.180674E+09 | 0.681976E+09 | 89717591.35 |
| November | 0.466286E+09 | 0.321602E+09 | 0.144684E+09 | 0.730376E+09 | 0.208965E+09 |
| December | 0.495387E+09 | 0.355537E+09 | 0.139850E+09 | 0.747011E+09 | 0.282530E+09 |
| Annual Sum or Average | 0.369759E+10 | 0.177937E+10 | 0.191822E+10 | 0.629238E+10 | 0.169893E+10 |
| Minimum of Months | 0.159351E+09 | 1647151.60 | 0.139850E+09 | 0.348421E+09 | 12803638.65 |
| Maximum of Months | 0.502791E+09 | 0.357141E+09 | 0.180674E+09 | 0.747011E+09 | 0.321022E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 W SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.158021E+09 | 85347902.52 | 72672624.48 | 0.191563E+09 | 0.229644E+09 |
| February | 0.161517E+09 | 81636932.67 | 79880196.06 | 0.204589E+09 | 0.179018E+09 |
| March | 0.176571E+09 | 78127728.44 | 98442962.80 | 0.238181E+09 | 0.165358E+09 |
| April | 0.211931E+09 | 97331851.08 | 0.114599E+09 | 0.329917E+09 | 0.101085E+09 |
| May | 0.182433E+09 | 59372310.88 | 0.123060E+09 | 0.359111E+09 | 20688585.49 |
| June | 0.196297E+09 | 68993422.12 | 0.127304E+09 | 0.394562E+09 | 15672660.16 |
| July | 0.184820E+09 | 51210314.87 | 0.133609E+09 | 0.377910E+09 | 8590485.05 |
| August | 0.186866E+09 | 56979874.95 | 0.129886E+09 | 0.377498E+09 | 15787479.75 |
| September | 0.166720E+09 | 57241413.69 | 0.109478E+09 | 0.316513E+09 | 26777385.27 |
| October | 0.175921E+09 | 75844789.61 | 0.100076E+09 | 0.314638E+09 | 60312883.53 |
| November | 0.146163E+09 | 73426852.63 | 72735834.01 | 0.204288E+09 | 0.147967E+09 |
| December | 0.145317E+09 | 77267943.06 | 68048957.49 | 0.186864E+09 | 0.197255E+09 |
| Annual Sum or Average | 0.209258E+10 | 0.862781E+09 | 0.122979E+10 | 0.349563E+10 | 0.116816E+10 |
| Minimum of Months | 0.145317E+09 | 51210314.87 | 68048957.49 | 0.186864E+09 | 8590485.05 |
| Maximum of Months | 0.211931E+09 | 97331851.08 | 0.133609E+09 | 0.394562E+09 | 0.229644E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 W NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.158021E+09 | 85347902.52 | 72672624.48 | 0.207996E+09 | 0.213753E+09 |
| February | 0.161517E+09 | 81636932.67 | 79880196.06 | 0.217010E+09 | 0.169322E+09 |
| March | 0.176571E+09 | 78127728.44 | 98442962.80 | 0.245586E+09 | 0.161059E+09 |
| April | 0.211931E+09 | 97331851.08 | 0.114599E+09 | 0.332541E+09 | 0.100954E+09 |
| May | 0.182433E+09 | 59372310.88 | 0.123060E+09 | 0.359303E+09 | 20730632.75 |
| June | 0.196297E+09 | 68993422.12 | 0.127304E+09 | 0.394117E+09 | 15794224.89 |
| July | 0.184820E+09 | 51210314.87 | 0.133609E+09 | 0.377701E+09 | 8625139.17 |
| August | 0.186866E+09 | 56979874.95 | 0.129886E+09 | 0.378665E+09 | 15695510.18 |
| September | 0.166720E+09 | 57241413.69 | 0.109478E+09 | 0.318986E+09 | 26208275.93 |
| October | 0.175921E+09 | 75844789.61 | 0.100076E+09 | 0.320799E+09 | 58039589.48 |
| November | 0.146163E+09 | 73426852.63 | 72735834.01 | 0.216394E+09 | 0.139275E+09 |
| December | 0.145317E+09 | 77267943.06 | 68048957.49 | 0.201343E+09 | 0.182813E+09 |
| Annual Sum or Average | 0.209258E+10 | 0.862781E+09 | 0.122979E+10 | 0.357044E+10 | 0.111227E+10 |
| Minimum of Months | 0.145317E+09 | 51210314.87 | 68048957.49 | 0.201343E+09 | 8625139.17 |
| Maximum of Months | 0.211931E+09 | 97331851.08 | 0.133609E+09 | 0.394117E+09 | 0.213753E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 87851305.19 | 0.00 | 87851305.19 | 61917126.08 | 0.346521E+09 |
| February | 93613281.56 | 0.00 | 93613281.56 | 73324146.78 | 0.272945E+09 |
| March | 0.120260E+09 | 5622.98 | 0.120255E+09 | 0.119763E+09 | 0.256245E+09 |
| April | 0.137691E+09 | 814454.99 | 0.136876E+09 | 0.180966E+09 | 0.157897E+09 |
| May | 0.161025E+09 | 6063506.41 | 0.154962E+09 | 0.337186E+09 | 30085635.99 |
| June | 0.176659E+09 | 12028244.03 | 0.164631E+09 | 0.385141E+09 | 22777001.98 |
| July | 0.177281E+09 | 6616296.66 | 0.170665E+09 | 0.389701E+09 | 12980937.78 |
| August | 0.159426E+09 | 1641530.34 | 0.157785E+09 | 0.349412E+09 | 23072313.26 |
| September | 0.132846E+09 | 25838.56 | 0.132820E+09 | 0.265868E+09 | 40072214.62 |
| October | 0.119234E+09 | 0.00 | 0.119234E+09 | 0.218252E+09 | 89981942.71 |
| November | 87597669.79 | 0.00 | 87597669.79 | 90649726.18 | 0.221829E+09 |
| December | 81667786.01 | 0.00 | 81667786.01 | 66307078.78 | 0.295227E+09 |
| Annual Sum or Average | 0.153515E+10 | 27195493.98 | 0.150796E+10 | 0.253849E+10 | 0.176963E+10 |
| Minimum of Months | 81667786.01 | 0.00 | 81667786.01 | 61917126.08 | 12980937.78 |
| Maximum of Months | 0.177281E+09 | 12028244.03 | 0.170665E+09 | 0.389701E+09 | 0.346521E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.502791E+09 | 0.357141E+09 | 0.145651E+09 | 0.725297E+09 | 0.318633E+09 |
| February | 0.418930E+09 | 0.272196E+09 | 0.146733E+09 | 0.611361E+09 | 0.252178E+09 |
| March | 0.290211E+09 | 0.128898E+09 | 0.161313E+09 | 0.428764E+09 | 0.246829E+09 |
| April | 0.215630E+09 | 54115104.10 | 0.161515E+09 | 0.347903E+09 | 0.157143E+09 |
| May | 0.167073E+09 | 7576796.02 | 0.159496E+09 | 0.351956E+09 | 30801337.77 |
| June | 0.159351E+09 | 1647151.60 | 0.157704E+09 | 0.347036E+09 | 23642307.14 |
| July | 0.172296E+09 | 3238841.76 | 0.169057E+09 | 0.380267E+09 | 12537078.56 |
| August | 0.200876E+09 | 22577599.97 | 0.178298E+09 | 0.439567E+09 | 23808898.18 |
| September | 0.238407E+09 | 65161043.25 | 0.173246E+09 | 0.477784E+09 | 40297783.05 |
| October | 0.370348E+09 | 0.189674E+09 | 0.180674E+09 | 0.680595E+09 | 88325995.25 |
| November | 0.466286E+09 | 0.321602E+09 | 0.144684E+09 | 0.727255E+09 | 0.207128E+09 |
| December | 0.495387E+09 | 0.355537E+09 | 0.139850E+09 | 0.745037E+09 | 0.279826E+09 |
| Annual Sum or Average | 0.369759E+10 | 0.177937E+10 | 0.191822E+10 | 0.626282E+10 | 0.168115E+10 |
| Minimum of Months | 0.159351E+09 | 1647151.60 | 0.139850E+09 | 0.347036E+09 | 12537078.56 |
| Maximum of Months | 0.502791E+09 | 0.357141E+09 | 0.180674E+09 | 0.745037E+09 | 0.318633E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 E SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.149391E+09 | 76380900.21 | 73009938.99 | 0.171627E+09 | 0.225596E+09 |
| February | 0.149295E+09 | 71797887.95 | 77497036.91 | 0.180292E+09 | 0.174047E+09 |
| March | 0.194919E+09 | 93866035.49 | 0.101053E+09 | 0.260857E+09 | 0.159229E+09 |
| April | 0.207495E+09 | 93994691.47 | 0.113500E+09 | 0.317390E+09 | 98171902.88 |
| May | 0.220559E+09 | 95705537.34 | 0.124853E+09 | 0.421638E+09 | 19020624.47 |
| June | 0.216360E+09 | 85835864.82 | 0.130524E+09 | 0.428796E+09 | 14383457.50 |
| July | 0.215710E+09 | 79049917.79 | 0.136660E+09 | 0.432695E+09 | 7877324.88 |
| August | 0.198680E+09 | 68252399.00 | 0.130428E+09 | 0.394810E+09 | 14607032.84 |
| September | 0.170060E+09 | 58356923.99 | 0.111703E+09 | 0.319732E+09 | 25484894.37 |
| October | 0.174276E+09 | 73745867.93 | 0.100530E+09 | 0.305114E+09 | 57494272.29 |
| November | 0.148984E+09 | 75969936.22 | 73014387.14 | 0.199829E+09 | 0.142594E+09 |
| December | 0.121301E+09 | 55018271.94 | 66283178.64 | 0.143169E+09 | 0.197041E+09 |
| Annual Sum or Average | 0.216703E+10 | 0.927974E+09 | 0.123906E+10 | 0.357595E+10 | 0.113555E+10 |
| Minimum of Months | 0.121301E+09 | 55018271.94 | 66283178.64 | 0.143169E+09 | 7877324.88 |
| Maximum of Months | 0.220559E+09 | 95705537.34 | 0.136660E+09 | 0.432695E+09 | 0.225596E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 E NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.149391E+09 | 76380900.21 | 73009938.99 | 0.184225E+09 | 0.204135E+09 |
| February | 0.149295E+09 | 71797887.95 | 77497036.91 | 0.190199E+09 | 0.161402E+09 |
| March | 0.194919E+09 | 93866035.49 | 0.101053E+09 | 0.267726E+09 | 0.153702E+09 |
| April | 0.207495E+09 | 93994691.47 | 0.113500E+09 | 0.319863E+09 | 97614466.62 |
| May | 0.220559E+09 | 95705537.34 | 0.124853E+09 | 0.421838E+09 | 19049640.23 |
| June | 0.216360E+09 | 85835864.82 | 0.130524E+09 | 0.428363E+09 | 14494040.94 |
| July | 0.215710E+09 | 79049917.79 | 0.136660E+09 | 0.432499E+09 | 7911900.85 |
| August | 0.198680E+09 | 68252399.00 | 0.130428E+09 | 0.395981E+09 | 14504903.41 |
| September | 0.170060E+09 | 58356923.99 | 0.111703E+09 | 0.322189E+09 | 24876307.64 |
| October | 0.174276E+09 | 73745867.93 | 0.100530E+09 | 0.311257E+09 | 54561992.13 |
| November | 0.148984E+09 | 75969936.22 | 73014387.14 | 0.210670E+09 | 0.132184E+09 |
| December | 0.121301E+09 | 55018271.94 | 66283178.64 | 0.154958E+09 | 0.178810E+09 |
| Annual Sum or Average | 0.216703E+10 | 0.927974E+09 | 0.123906E+10 | 0.363977E+10 | 0.106325E+10 |
| Minimum of Months | 0.121301E+09 | 55018271.94 | 66283178.64 | 0.154958E+09 | 7911900.85 |
| Maximum of Months | 0.220559E+09 | 95705537.34 | 0.136660E+09 | 0.432499E+09 | 0.204135E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 87851305.19 | 0.00 | 87851305.19 | 58958307.57 | 0.341971E+09 |
| February | 93613281.56 | 0.00 | 93613281.56 | 70121542.63 | 0.269208E+09 |
| March | 0.120260E+09 | 5622.98 | 0.120255E+09 | 0.115040E+09 | 0.253627E+09 |
| April | 0.137691E+09 | 814454.99 | 0.136876E+09 | 0.176844E+09 | 0.155280E+09 |
| May | 0.161025E+09 | 6063506.41 | 0.154962E+09 | 0.335411E+09 | 29569861.20 |
| June | 0.176659E+09 | 12028244.03 | 0.164631E+09 | 0.383832E+09 | 22275384.46 |
| July | 0.177281E+09 | 6616296.66 | 0.170665E+09 | 0.388373E+09 | 12730673.79 |
| August | 0.159426E+09 | 1641530.34 | 0.157785E+09 | 0.348641E+09 | 22514565.73 |
| September | 0.132846E+09 | 25838.56 | 0.132820E+09 | 0.265107E+09 | 39318488.85 |
| October | 0.119234E+09 | 0.00 | 0.119234E+09 | 0.216719E+09 | 87835140.70 |
| November | 87597669.79 | 0.00 | 87597669.79 | 87099336.62 | 0.219074E+09 |
| December | 81667786.01 | 0.00 | 81667786.01 | 64409180.09 | 0.290911E+09 |
| Annual Sum or Average | 0.153515E+10 | 27195493.98 | 0.150796E+10 | 0.251055E+10 | 0.174431E+10 |
| Minimum of Months | 81667786.01 | 0.00 | 81667786.01 | 58958307.57 | 12730673.79 |
| Maximum of Months | 0.177281E+09 | 12028244.03 | 0.170665E+09 | 0.388373E+09 | 0.341971E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N N1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 87851305.19 | 0.00 | 87851305.19 | 61533120.97 | 0.350990E+09 |
| February | 93613281.56 | 0.00 | 93613281.56 | 73240952.21 | 0.276462E+09 |
| March | 0.120260E+09 | 5622.98 | 0.120255E+09 | 0.120481E+09 | 0.259784E+09 |
| April | 0.137691E+09 | 814454.99 | 0.136876E+09 | 0.183433E+09 | 0.157203E+09 |
| May | 0.161025E+09 | 6063506.41 | 0.154962E+09 | 0.342400E+09 | 29080738.05 |
| June | 0.176659E+09 | 12028244.03 | 0.164631E+09 | 0.391131E+09 | 21796951.28 |
| July | 0.177281E+09 | 6616296.66 | 0.170665E+09 | 0.396076E+09 | 12352318.96 |
| August | 0.159426E+09 | 1641530.34 | 0.157785E+09 | 0.355394E+09 | 22113970.66 |
| September | 0.132846E+09 | 25838.56 | 0.132820E+09 | 0.270486E+09 | 39083342.73 |
| October | 0.119234E+09 | 0.00 | 0.119234E+09 | 0.222009E+09 | 89435606.62 |
| November | 87597669.79 | 0.00 | 87597669.79 | 90430753.61 | 0.225531E+09 |
| December | 81667786.01 | 0.00 | 81667786.01 | 65977039.45 | 0.301277E+09 |
| Annual Sum or Average | 0.153515E+10 | 27195493.98 | 0.150796E+10 | 0.257259E+10 | 0.178511E+10 |
| Minimum of Months | 81667786.01 | 0.00 | 81667786.01 | 61533120.97 | 12352318.96 |
| Maximum of Months | 0.177281E+09 | 12028244.03 | 0.170665E+09 | 0.396076E+09 | 0.350990E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N N2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 87851305.19 | 0.00 | 87851305.19 | 61322301.64 | 0.350657E+09 |
| February | 93613281.56 | 0.00 | 93613281.56 | 73003574.28 | 0.276209E+09 |
| March | 0.120260E+09 | 5622.98 | 0.120255E+09 | 0.120106E+09 | 0.259621E+09 |
| April | 0.137691E+09 | 814454.99 | 0.136876E+09 | 0.183105E+09 | 0.157087E+09 |
| May | 0.161025E+09 | 6063506.41 | 0.154962E+09 | 0.342318E+09 | 29053699.71 |
| June | 0.176659E+09 | 12028244.03 | 0.164631E+09 | 0.391070E+09 | 21770023.90 |
| July | 0.177281E+09 | 6616296.66 | 0.170665E+09 | 0.396017E+09 | 12338329.98 |
| August | 0.159426E+09 | 1641530.34 | 0.157785E+09 | 0.355357E+09 | 22079773.79 |
| September | 0.132846E+09 | 25838.56 | 0.132820E+09 | 0.270444E+09 | 39037327.34 |
| October | 0.119234E+09 | 0.00 | 0.119234E+09 | 0.221918E+09 | 89278849.17 |
| November | 87597669.79 | 0.00 | 87597669.79 | 90154706.12 | 0.225380E+09 |
| December | 81667786.01 | 0.00 | 81667786.01 | 65849835.94 | 0.300870E+09 |
| Annual Sum or Average | 0.153515E+10 | 27195493.98 | 0.150796E+10 | 0.257066E+10 | 0.178338E+10 |
| Minimum of Months | 81667786.01 | 0.00 | 81667786.01 | 61322301.64 | 12338329.98 |
| Maximum of Months | 0.177281E+09 | 12028244.03 | 0.170665E+09 | 0.396017E+09 | 0.350657E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S S1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.502791E+09 | 0.357141E+09 | 0.145651E+09 | 0.725428E+09 | 0.330887E+09 |
| February | 0.418930E+09 | 0.272196E+09 | 0.146733E+09 | 0.612630E+09 | 0.260853E+09 |
| March | 0.290211E+09 | 0.128898E+09 | 0.161313E+09 | 0.433451E+09 | 0.253824E+09 |
| April | 0.215630E+09 | 54115104.10 | 0.161515E+09 | 0.354075E+09 | 0.159337E+09 |
| May | 0.167073E+09 | 7576796.02 | 0.159496E+09 | 0.359027E+09 | 30287669.90 |
| June | 0.159351E+09 | 1647151.60 | 0.157704E+09 | 0.354347E+09 | 23120070.70 |
| July | 0.172296E+09 | 3238841.76 | 0.169057E+09 | 0.388144E+09 | 12151251.97 |
| August | 0.200876E+09 | 22577599.97 | 0.178298E+09 | 0.446230E+09 | 23414291.46 |
| September | 0.238407E+09 | 65161043.25 | 0.173246E+09 | 0.482885E+09 | 40129863.73 |
| October | 0.370348E+09 | 0.189674E+09 | 0.180674E+09 | 0.685037E+09 | 89714027.25 |
| November | 0.466286E+09 | 0.321602E+09 | 0.144684E+09 | 0.728939E+09 | 0.213055E+09 |
| December | 0.495387E+09 | 0.355537E+09 | 0.139850E+09 | 0.744011E+09 | 0.291352E+09 |
| Annual Sum or Average | 0.369759E+10 | 0.177937E+10 | 0.191822E+10 | 0.631420E+10 | 0.172813E+10 |
| Minimum of Months | 0.159351E+09 | 1647151.60 | 0.139850E+09 | 0.354075E+09 | 12151251.97 |
| Maximum of Months | 0.502791E+09 | 0.357141E+09 | 0.180674E+09 | 0.744011E+09 | 0.330887E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S S2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.502791E+09 | 0.357141E+09 | 0.145651E+09 | 0.725128E+09 | 0.330757E+09 |
| February | 0.418930E+09 | 0.272196E+09 | 0.146733E+09 | 0.612399E+09 | 0.260658E+09 |
| March | 0.290211E+09 | 0.128898E+09 | 0.161313E+09 | 0.433040E+09 | 0.253807E+09 |
| April | 0.215630E+09 | 54115104.10 | 0.161515E+09 | 0.353788E+09 | 0.159225E+09 |
| May | 0.167073E+09 | 7576796.02 | 0.159496E+09 | 0.358941E+09 | 30260129.96 |
| June | 0.159351E+09 | 1647151.60 | 0.157704E+09 | 0.354281E+09 | 23091061.97 |
| July | 0.172296E+09 | 3238841.76 | 0.169057E+09 | 0.388081E+09 | 12135594.79 |
| August | 0.200876E+09 | 22577599.97 | 0.178298E+09 | 0.446193E+09 | 23374148.41 |
| September | 0.238407E+09 | 65161043.25 | 0.173246E+09 | 0.482846E+09 | 40083959.85 |
| October | 0.370348E+09 | 0.189674E+09 | 0.180674E+09 | 0.684951E+09 | 89632368.02 |
| November | 0.466286E+09 | 0.321602E+09 | 0.144684E+09 | 0.728748E+09 | 0.212956E+09 |
| December | 0.495387E+09 | 0.355537E+09 | 0.139850E+09 | 0.743889E+09 | 0.291146E+09 |
| Annual Sum or Average | 0.369759E+10 | 0.177937E+10 | 0.191822E+10 | 0.631229E+10 | 0.172713E+10 |
| Minimum of Months | 0.159351E+09 | 1647151.60 | 0.139850E+09 | 0.353788E+09 | 12135594.79 |
| Maximum of Months | 0.502791E+09 | 0.357141E+09 | 0.180674E+09 | 0.743889E+09 | 0.330757E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW14
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 35846939.95 | 18327907.91 | 17519032.04 | 41322928.52 | 57479981.03 |
| February | 35823924.91 | 17228195.46 | 18595729.45 | 43096302.45 | 45199336.13 |
| March | 46771595.74 | 22523537.29 | 24248058.45 | 61431521.78 | 42982927.37 |
| April | 49789167.74 | 22554408.81 | 27234758.93 | 73648545.70 | 28044770.86 |
| May | 52923985.63 | 22964933.24 | 29959052.39 | 95651794.60 | 8222994.51 |
| June | 51916412.70 | 20596665.15 | 31319747.55 | 97415560.61 | 6858281.32 |
| July | 51760477.65 | 18968349.54 | 32792128.11 | 97416140.52 | 4717146.20 |
| August | 47674155.21 | 16377440.95 | 31296714.25 | 89015322.70 | 6792066.51 |
| September | 40806582.60 | 14002981.45 | 26803601.15 | 72375514.36 | 9935077.14 |
| October | 41818126.21 | 17695621.18 | 24122505.02 | 69887114.93 | 18123057.84 |
| November | 35749394.81 | 18229295.42 | 17520099.39 | 47403822.54 | 38237868.73 |
| December | 29106776.81 | 13201858.30 | 15904918.51 | 34213310.32 | 51249955.20 |
| Annual Sum or Average | 0.519988E+09 | 0.222671E+09 | 0.297316E+09 | 0.822878E+09 | 0.317843E+09 |
| Minimum of Months | 29106776.81 | 13201858.30 | 15904918.51 | 34213310.32 | 4717146.20 |
| Maximum of Months | 52923985.63 | 22964933.24 | 32792128.11 | 97416140.52 | 57479981.03 |
Report: WindowEnergyReportMonthly
For: ENTRANCE DOOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.106761E+09 | 54585070.89 | 52176037.26 | 0.120304E+09 | 0.179306E+09 |
| February | 0.106693E+09 | 51309853.55 | 55382710.10 | 0.128260E+09 | 0.136362E+09 |
| March | 0.139297E+09 | 67080699.33 | 72216752.51 | 0.183758E+09 | 0.129388E+09 |
| April | 0.148285E+09 | 67172642.41 | 81111889.83 | 0.220411E+09 | 83748222.37 |
| May | 0.157621E+09 | 68395286.33 | 89225513.73 | 0.278690E+09 | 31189470.52 |
| June | 0.154620E+09 | 61341994.57 | 93278002.55 | 0.282163E+09 | 27487123.04 |
| July | 0.154156E+09 | 56492465.45 | 97663118.26 | 0.280140E+09 | 21932777.57 |
| August | 0.141985E+09 | 48776094.91 | 93209403.65 | 0.254828E+09 | 29322503.04 |
| September | 0.121532E+09 | 41704363.58 | 79827794.65 | 0.207456E+09 | 39139624.00 |
| October | 0.124545E+09 | 52701963.68 | 71842823.17 | 0.201823E+09 | 64145452.48 |
| November | 0.106471E+09 | 54291378.37 | 52179216.10 | 0.137548E+09 | 0.121377E+09 |
| December | 86687224.96 | 39318419.47 | 47368805.49 | 98142699.22 | 0.163629E+09 |
| Annual Sum or Average | 0.154865E+10 | 0.663170E+09 | 0.885482E+09 | 0.239352E+10 | 0.102703E+10 |
| Minimum of Months | 86687224.96 | 39318419.47 | 47368805.49 | 98142699.22 | 21932777.57 |
| Maximum of Months | 0.157621E+09 | 68395286.33 | 97663118.26 | 0.282163E+09 | 0.179306E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW14
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 35846939.95 | 18327907.91 | 17519032.04 | 38223360.83 | 64905593.92 |
| February | 35823924.91 | 17228195.46 | 18595729.45 | 40816383.79 | 49882034.62 |
| March | 46771595.74 | 22523537.29 | 24248058.45 | 59338745.19 | 47230274.81 |
| April | 49789167.74 | 22554408.81 | 27234758.93 | 73299666.53 | 28846070.61 |
| May | 52923985.63 | 22964933.24 | 29959052.39 | 97132083.73 | 8008667.75 |
| June | 51916412.70 | 20596665.15 | 31319747.55 | 99014940.17 | 6599818.32 |
| July | 51760477.65 | 18968349.54 | 32792128.11 | 99233576.43 | 4437326.16 |
| August | 47674155.21 | 16377440.95 | 31296714.25 | 90651563.92 | 6528329.09 |
| September | 40806582.60 | 14002981.45 | 26803601.15 | 73529505.04 | 9782585.67 |
| October | 41818126.21 | 17695621.18 | 24122505.02 | 70450808.29 | 18560321.80 |
| November | 35749394.81 | 18229295.42 | 17520099.39 | 45861402.93 | 40896043.87 |
| December | 29106776.81 | 13201858.30 | 15904918.51 | 31958207.93 | 57728575.71 |
| Annual Sum or Average | 0.519988E+09 | 0.222671E+09 | 0.297316E+09 | 0.819510E+09 | 0.343406E+09 |
| Minimum of Months | 29106776.81 | 13201858.30 | 15904918.51 | 31958207.93 | 4437326.16 |
| Maximum of Months | 52923985.63 | 22964933.24 | 32792128.11 | 99233576.43 | 64905593.92 |
Report: WindowZoneSummaryMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 337.77 | 219.75 | 246.72 | 165.21 | 81.51 | 0.00 | 0.00 |
| February | 339.36 | 184.68 | 239.93 | 146.26 | 93.67 | 0.00 | 0.00 |
| March | 255.58 | 158.44 | 174.28 | 77.29 | 96.98 | 0.00 | 0.00 |
| April | 272.09 | 97.03 | 164.95 | 58.43 | 106.53 | 0.00 | 0.00 |
| May | 274.42 | 18.98 | 130.49 | 25.00 | 105.49 | 0.00 | 0.00 |
| June | 294.63 | 15.47 | 137.21 | 27.25 | 109.96 | 0.00 | 0.00 |
| July | 289.91 | 8.67 | 133.33 | 20.33 | 113.00 | 0.00 | 0.00 |
| August | 309.70 | 17.22 | 144.77 | 29.70 | 115.06 | 0.00 | 0.00 |
| September | 310.68 | 29.35 | 156.30 | 47.22 | 109.08 | 0.00 | 0.00 |
| October | 375.87 | 60.83 | 203.95 | 99.13 | 104.82 | 0.00 | 0.00 |
| November | 359.91 | 143.93 | 236.28 | 152.40 | 83.88 | 0.00 | 0.00 |
| December | 345.00 | 194.23 | 239.21 | 161.59 | 77.62 | 0.00 | 0.00 |
| Annual Sum or Average | 313.58 | 95.25 | 183.60 | 83.78 | 99.82 | 0.00 | 0.00 |
| Minimum of Months | 255.58 | 8.67 | 130.49 | 20.33 | 77.62 | 0.00 | 0.00 |
| Maximum of Months | 375.87 | 219.75 | 246.72 | 165.21 | 115.06 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 91.48 | 224.87 | 91.80 | 31.87 | 59.93 | 0.00 | 0.00 |
| February | 118.12 | 185.65 | 105.46 | 33.75 | 71.72 | 0.00 | 0.00 |
| March | 139.29 | 157.14 | 110.82 | 29.17 | 81.65 | 0.00 | 0.00 |
| April | 206.51 | 95.14 | 134.88 | 37.87 | 97.02 | 0.00 | 0.00 |
| May | 267.97 | 18.34 | 128.23 | 24.43 | 103.80 | 0.00 | 0.00 |
| June | 308.59 | 14.99 | 143.89 | 31.26 | 112.63 | 0.00 | 0.00 |
| July | 292.85 | 8.78 | 135.19 | 21.59 | 113.60 | 0.00 | 0.00 |
| August | 275.55 | 16.61 | 129.29 | 21.89 | 107.40 | 0.00 | 0.00 |
| September | 228.40 | 28.39 | 115.57 | 22.09 | 93.48 | 0.00 | 0.00 |
| October | 201.99 | 60.19 | 110.20 | 28.32 | 81.88 | 0.00 | 0.00 |
| November | 113.33 | 150.64 | 90.19 | 28.33 | 61.86 | 0.00 | 0.00 |
| December | 91.71 | 199.40 | 84.75 | 28.85 | 55.90 | 0.00 | 0.00 |
| Annual Sum or Average | 195.06 | 96.21 | 115.03 | 28.22 | 86.81 | 0.00 | 0.00 |
| Minimum of Months | 91.48 | 8.78 | 84.75 | 21.59 | 55.90 | 0.00 | 0.00 |
| Maximum of Months | 308.59 | 224.87 | 143.89 | 37.87 | 113.60 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 329.50 | 223.23 | 243.50 | 161.86 | 81.64 | 0.00 | 0.00 |
| February | 330.30 | 186.43 | 234.88 | 142.19 | 92.69 | 0.00 | 0.00 |
| March | 260.46 | 161.71 | 181.13 | 83.17 | 97.96 | 0.00 | 0.00 |
| April | 258.25 | 109.73 | 163.24 | 57.14 | 106.10 | 0.00 | 0.00 |
| May | 273.95 | 44.96 | 144.73 | 38.56 | 106.16 | 0.00 | 0.00 |
| June | 282.17 | 42.58 | 144.95 | 33.75 | 111.20 | 0.00 | 0.00 |
| July | 275.84 | 36.86 | 144.86 | 30.72 | 114.14 | 0.00 | 0.00 |
| August | 288.86 | 47.71 | 149.18 | 33.91 | 115.27 | 0.00 | 0.00 |
| September | 287.86 | 62.62 | 157.59 | 47.65 | 109.93 | 0.00 | 0.00 |
| October | 354.78 | 93.58 | 203.34 | 98.35 | 104.99 | 0.00 | 0.00 |
| November | 353.88 | 162.60 | 237.37 | 153.38 | 83.99 | 0.00 | 0.00 |
| December | 325.78 | 205.61 | 230.25 | 153.28 | 76.96 | 0.00 | 0.00 |
| Annual Sum or Average | 301.64 | 114.44 | 185.97 | 85.85 | 100.12 | 0.00 | 0.00 |
| Minimum of Months | 258.25 | 36.86 | 144.73 | 30.72 | 76.96 | 0.00 | 0.00 |
| Maximum of Months | 354.78 | 223.23 | 243.50 | 161.86 | 115.27 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 77.40 | 216.75 | 88.58 | 28.52 | 60.06 | 0.00 | 0.00 |
| February | 101.92 | 177.99 | 100.41 | 29.68 | 70.73 | 0.00 | 0.00 |
| March | 142.77 | 150.33 | 117.67 | 35.05 | 82.63 | 0.00 | 0.00 |
| April | 199.48 | 91.91 | 133.17 | 36.58 | 96.60 | 0.00 | 0.00 |
| May | 291.50 | 18.00 | 142.47 | 38.00 | 104.47 | 0.00 | 0.00 |
| June | 321.72 | 14.59 | 151.63 | 37.76 | 113.87 | 0.00 | 0.00 |
| July | 313.01 | 8.60 | 146.73 | 31.98 | 114.74 | 0.00 | 0.00 |
| August | 281.82 | 16.02 | 133.70 | 26.10 | 107.61 | 0.00 | 0.00 |
| September | 229.34 | 27.53 | 116.86 | 22.52 | 94.34 | 0.00 | 0.00 |
| October | 197.44 | 57.72 | 109.58 | 27.53 | 82.05 | 0.00 | 0.00 |
| November | 105.63 | 142.39 | 91.27 | 29.31 | 61.96 | 0.00 | 0.00 |
| December | 71.69 | 194.63 | 75.78 | 20.54 | 55.24 | 0.00 | 0.00 |
| Annual Sum or Average | 195.02 | 92.60 | 117.40 | 30.29 | 87.11 | 0.00 | 0.00 |
| Minimum of Months | 71.69 | 8.60 | 75.78 | 20.54 | 55.24 | 0.00 | 0.00 |
| Maximum of Months | 321.72 | 216.75 | 151.63 | 38.00 | 114.74 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 20.75 | 147.82 | 32.80 | 0.00 | 32.80 | 0.00 | 0.00 |
| February | 30.49 | 121.40 | 38.70 | 0.00 | 38.70 | 0.00 | 0.00 |
| March | 46.17 | 100.86 | 44.90 | 0.00 | 44.90 | 0.00 | 0.00 |
| April | 74.72 | 58.80 | 53.12 | 0.31 | 52.81 | 0.00 | 0.00 |
| May | 131.55 | 10.76 | 60.12 | 2.26 | 57.86 | 0.00 | 0.00 |
| June | 154.62 | 8.61 | 68.16 | 4.64 | 63.51 | 0.00 | 0.00 |
| July | 150.87 | 4.98 | 66.19 | 2.47 | 63.72 | 0.00 | 0.00 |
| August | 134.42 | 9.21 | 59.52 | 0.61 | 58.91 | 0.00 | 0.00 |
| September | 105.63 | 16.30 | 51.25 | 0.01 | 51.24 | 0.00 | 0.00 |
| October | 83.28 | 35.97 | 44.52 | 0.00 | 44.52 | 0.00 | 0.00 |
| November | 33.53 | 93.92 | 33.80 | 0.00 | 33.80 | 0.00 | 0.00 |
| December | 22.39 | 128.31 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Annual Sum or Average | 82.69 | 61.10 | 48.68 | 0.86 | 47.82 | 0.00 | 0.00 |
| Minimum of Months | 20.75 | 4.98 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Maximum of Months | 154.62 | 147.82 | 68.16 | 4.64 | 63.72 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 20.73 | 147.83 | 32.80 | 0.00 | 32.80 | 0.00 | 0.00 |
| February | 30.47 | 121.41 | 38.70 | 0.00 | 38.70 | 0.00 | 0.00 |
| March | 46.13 | 100.88 | 44.90 | 0.00 | 44.90 | 0.00 | 0.00 |
| April | 74.69 | 58.80 | 53.12 | 0.31 | 52.81 | 0.00 | 0.00 |
| May | 131.53 | 10.77 | 60.12 | 2.26 | 57.86 | 0.00 | 0.00 |
| June | 154.61 | 8.61 | 68.16 | 4.64 | 63.51 | 0.00 | 0.00 |
| July | 150.86 | 4.98 | 66.19 | 2.47 | 63.72 | 0.00 | 0.00 |
| August | 134.42 | 9.20 | 59.52 | 0.61 | 58.91 | 0.00 | 0.00 |
| September | 105.62 | 16.29 | 51.25 | 0.01 | 51.24 | 0.00 | 0.00 |
| October | 83.28 | 35.95 | 44.52 | 0.00 | 44.52 | 0.00 | 0.00 |
| November | 33.51 | 93.91 | 33.80 | 0.00 | 33.80 | 0.00 | 0.00 |
| December | 22.40 | 128.25 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Annual Sum or Average | 82.67 | 61.10 | 48.68 | 0.86 | 47.82 | 0.00 | 0.00 |
| Minimum of Months | 20.73 | 4.98 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Maximum of Months | 154.61 | 147.83 | 68.16 | 4.64 | 63.72 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 270.74 | 133.34 | 187.72 | 133.34 | 54.38 | 0.00 | 0.00 |
| February | 255.54 | 113.03 | 173.17 | 112.51 | 60.65 | 0.00 | 0.00 |
| March | 164.59 | 98.90 | 108.35 | 48.13 | 60.23 | 0.00 | 0.00 |
| April | 141.35 | 60.44 | 83.19 | 20.88 | 62.31 | 0.00 | 0.00 |
| May | 137.83 | 11.26 | 62.38 | 2.83 | 59.55 | 0.00 | 0.00 |
| June | 140.33 | 9.05 | 61.48 | 0.64 | 60.84 | 0.00 | 0.00 |
| July | 147.82 | 4.90 | 64.33 | 1.21 | 63.12 | 0.00 | 0.00 |
| August | 168.81 | 9.75 | 75.00 | 8.43 | 66.57 | 0.00 | 0.00 |
| September | 188.51 | 16.97 | 91.98 | 25.14 | 66.84 | 0.00 | 0.00 |
| October | 258.37 | 35.94 | 138.27 | 70.82 | 67.46 | 0.00 | 0.00 |
| November | 283.32 | 86.41 | 179.89 | 124.07 | 55.82 | 0.00 | 0.00 |
| December | 278.27 | 117.82 | 184.96 | 132.74 | 52.21 | 0.00 | 0.00 |
| Annual Sum or Average | 202.68 | 57.86 | 117.25 | 56.42 | 60.83 | 0.00 | 0.00 |
| Minimum of Months | 137.83 | 4.90 | 61.48 | 0.64 | 52.21 | 0.00 | 0.00 |
| Maximum of Months | 283.32 | 133.34 | 187.72 | 133.34 | 67.46 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 270.65 | 133.43 | 187.72 | 133.34 | 54.38 | 0.00 | 0.00 |
| February | 255.53 | 113.00 | 173.17 | 112.51 | 60.65 | 0.00 | 0.00 |
| March | 164.44 | 99.04 | 108.35 | 48.13 | 60.23 | 0.00 | 0.00 |
| April | 140.97 | 60.87 | 83.19 | 20.88 | 62.31 | 0.00 | 0.00 |
| May | 137.01 | 11.86 | 62.38 | 2.83 | 59.55 | 0.00 | 0.00 |
| June | 139.45 | 9.61 | 61.48 | 0.64 | 60.84 | 0.00 | 0.00 |
| July | 146.68 | 5.34 | 64.33 | 1.21 | 63.12 | 0.00 | 0.00 |
| August | 167.89 | 10.34 | 75.00 | 8.43 | 66.57 | 0.00 | 0.00 |
| September | 187.76 | 17.74 | 91.98 | 25.14 | 66.84 | 0.00 | 0.00 |
| October | 257.70 | 36.73 | 138.27 | 70.82 | 67.46 | 0.00 | 0.00 |
| November | 282.98 | 86.89 | 179.89 | 124.07 | 55.82 | 0.00 | 0.00 |
| December | 278.10 | 118.06 | 184.96 | 132.74 | 52.21 | 0.00 | 0.00 |
| Annual Sum or Average | 202.15 | 58.29 | 117.25 | 56.42 | 60.83 | 0.00 | 0.00 |
| Minimum of Months | 137.01 | 5.34 | 61.48 | 0.64 | 52.21 | 0.00 | 0.00 |
| Maximum of Months | 282.98 | 133.43 | 187.72 | 133.34 | 67.46 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 334.09 | 221.75 | 246.72 | 165.21 | 81.51 | 0.00 | 0.00 |
| February | 333.14 | 190.58 | 239.93 | 146.26 | 93.67 | 0.00 | 0.00 |
| March | 248.42 | 167.04 | 174.28 | 77.29 | 96.98 | 0.00 | 0.00 |
| April | 265.74 | 102.67 | 164.95 | 58.43 | 106.53 | 0.00 | 0.00 |
| May | 272.52 | 19.62 | 130.49 | 25.00 | 105.49 | 0.00 | 0.00 |
| June | 293.72 | 15.50 | 137.21 | 27.25 | 109.96 | 0.00 | 0.00 |
| July | 290.95 | 7.97 | 133.33 | 20.33 | 113.00 | 0.00 | 0.00 |
| August | 312.42 | 15.05 | 144.77 | 29.70 | 115.06 | 0.00 | 0.00 |
| September | 312.79 | 26.21 | 156.30 | 47.22 | 109.08 | 0.00 | 0.00 |
| October | 377.24 | 57.70 | 203.95 | 99.13 | 104.82 | 0.00 | 0.00 |
| November | 359.08 | 142.53 | 236.28 | 152.40 | 83.88 | 0.00 | 0.00 |
| December | 343.12 | 194.01 | 239.21 | 161.59 | 77.62 | 0.00 | 0.00 |
| Annual Sum or Average | 311.80 | 96.22 | 183.60 | 83.78 | 99.82 | 0.00 | 0.00 |
| Minimum of Months | 248.42 | 7.97 | 130.49 | 20.33 | 77.62 | 0.00 | 0.00 |
| Maximum of Months | 377.24 | 221.75 | 246.72 | 165.21 | 115.06 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 89.05 | 229.79 | 91.80 | 31.87 | 59.93 | 0.00 | 0.00 |
| February | 111.94 | 197.06 | 105.46 | 33.75 | 71.72 | 0.00 | 0.00 |
| March | 131.96 | 169.16 | 110.82 | 29.17 | 81.65 | 0.00 | 0.00 |
| April | 200.08 | 101.69 | 134.88 | 37.87 | 97.02 | 0.00 | 0.00 |
| May | 266.08 | 18.92 | 128.23 | 24.43 | 103.80 | 0.00 | 0.00 |
| June | 307.72 | 14.90 | 143.89 | 31.26 | 112.63 | 0.00 | 0.00 |
| July | 293.91 | 8.06 | 135.19 | 21.59 | 113.60 | 0.00 | 0.00 |
| August | 278.50 | 14.47 | 129.29 | 21.89 | 107.40 | 0.00 | 0.00 |
| September | 230.92 | 25.44 | 115.57 | 22.09 | 93.48 | 0.00 | 0.00 |
| October | 204.28 | 57.20 | 110.20 | 28.32 | 81.88 | 0.00 | 0.00 |
| November | 113.84 | 149.65 | 90.19 | 28.33 | 61.86 | 0.00 | 0.00 |
| December | 91.60 | 199.33 | 84.75 | 28.85 | 55.90 | 0.00 | 0.00 |
| Annual Sum or Average | 193.77 | 98.28 | 115.03 | 28.22 | 86.81 | 0.00 | 0.00 |
| Minimum of Months | 89.05 | 8.06 | 84.75 | 21.59 | 55.90 | 0.00 | 0.00 |
| Maximum of Months | 307.72 | 229.79 | 143.89 | 37.87 | 113.60 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 325.80 | 219.38 | 243.50 | 161.86 | 81.64 | 0.00 | 0.00 |
| February | 321.99 | 187.54 | 234.88 | 142.19 | 92.69 | 0.00 | 0.00 |
| March | 253.82 | 162.29 | 181.13 | 83.17 | 97.96 | 0.00 | 0.00 |
| April | 258.11 | 99.25 | 163.24 | 57.14 | 106.10 | 0.00 | 0.00 |
| May | 295.25 | 18.55 | 144.73 | 38.56 | 106.16 | 0.00 | 0.00 |
| June | 306.36 | 14.62 | 144.95 | 33.75 | 111.20 | 0.00 | 0.00 |
| July | 311.05 | 7.66 | 144.86 | 30.72 | 114.14 | 0.00 | 0.00 |
| August | 318.56 | 14.31 | 149.18 | 33.91 | 115.27 | 0.00 | 0.00 |
| September | 313.80 | 25.40 | 157.59 | 47.65 | 109.93 | 0.00 | 0.00 |
| October | 373.28 | 56.09 | 203.34 | 98.35 | 104.99 | 0.00 | 0.00 |
| November | 357.47 | 140.73 | 237.37 | 153.38 | 83.99 | 0.00 | 0.00 |
| December | 326.47 | 193.22 | 230.25 | 153.28 | 76.96 | 0.00 | 0.00 |
| Annual Sum or Average | 313.48 | 94.43 | 185.97 | 85.85 | 100.12 | 0.00 | 0.00 |
| Minimum of Months | 253.82 | 7.66 | 144.73 | 30.72 | 76.96 | 0.00 | 0.00 |
| Maximum of Months | 373.28 | 219.38 | 243.50 | 161.86 | 115.27 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 74.80 | 221.62 | 88.58 | 28.52 | 60.06 | 0.00 | 0.00 |
| February | 95.71 | 188.87 | 100.41 | 29.68 | 70.73 | 0.00 | 0.00 |
| March | 134.80 | 161.57 | 117.67 | 35.05 | 82.63 | 0.00 | 0.00 |
| April | 192.58 | 98.42 | 133.17 | 36.58 | 96.60 | 0.00 | 0.00 |
| May | 289.42 | 18.44 | 142.47 | 38.00 | 104.47 | 0.00 | 0.00 |
| June | 320.79 | 14.43 | 151.63 | 37.76 | 113.87 | 0.00 | 0.00 |
| July | 314.06 | 7.81 | 146.73 | 31.98 | 114.74 | 0.00 | 0.00 |
| August | 284.77 | 13.87 | 133.70 | 26.10 | 107.61 | 0.00 | 0.00 |
| September | 231.90 | 24.60 | 116.86 | 22.52 | 94.34 | 0.00 | 0.00 |
| October | 199.65 | 54.71 | 109.58 | 27.53 | 82.05 | 0.00 | 0.00 |
| November | 105.99 | 141.19 | 91.27 | 29.31 | 61.96 | 0.00 | 0.00 |
| December | 71.46 | 194.47 | 75.78 | 20.54 | 55.24 | 0.00 | 0.00 |
| Annual Sum or Average | 193.58 | 94.51 | 117.40 | 30.29 | 87.11 | 0.00 | 0.00 |
| Minimum of Months | 71.46 | 7.81 | 75.78 | 20.54 | 55.24 | 0.00 | 0.00 |
| Maximum of Months | 320.79 | 221.62 | 151.63 | 38.00 | 114.74 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 19.72 | 151.75 | 32.80 | 0.00 | 32.80 | 0.00 | 0.00 |
| February | 28.28 | 127.50 | 38.70 | 0.00 | 38.70 | 0.00 | 0.00 |
| March | 43.31 | 106.74 | 44.90 | 0.00 | 44.90 | 0.00 | 0.00 |
| April | 72.29 | 61.71 | 53.12 | 0.31 | 52.81 | 0.00 | 0.00 |
| May | 131.15 | 10.76 | 60.12 | 2.26 | 57.86 | 0.00 | 0.00 |
| June | 154.71 | 8.34 | 68.16 | 4.64 | 63.51 | 0.00 | 0.00 |
| July | 151.84 | 4.52 | 66.19 | 2.47 | 63.72 | 0.00 | 0.00 |
| August | 136.18 | 8.10 | 59.52 | 0.61 | 58.91 | 0.00 | 0.00 |
| September | 107.12 | 14.77 | 51.25 | 0.01 | 51.24 | 0.00 | 0.00 |
| October | 84.64 | 34.42 | 44.52 | 0.00 | 44.52 | 0.00 | 0.00 |
| November | 33.85 | 93.56 | 33.80 | 0.00 | 33.80 | 0.00 | 0.00 |
| December | 22.33 | 129.30 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Annual Sum or Average | 82.45 | 62.29 | 48.68 | 0.86 | 47.82 | 0.00 | 0.00 |
| Minimum of Months | 19.72 | 4.52 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Maximum of Months | 154.71 | 151.75 | 68.16 | 4.64 | 63.72 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 19.70 | 151.78 | 32.80 | 0.00 | 32.80 | 0.00 | 0.00 |
| February | 28.25 | 127.48 | 38.70 | 0.00 | 38.70 | 0.00 | 0.00 |
| March | 43.26 | 106.76 | 44.90 | 0.00 | 44.90 | 0.00 | 0.00 |
| April | 72.24 | 61.72 | 53.12 | 0.31 | 52.81 | 0.00 | 0.00 |
| May | 131.13 | 10.76 | 60.12 | 2.26 | 57.86 | 0.00 | 0.00 |
| June | 154.70 | 8.34 | 68.16 | 4.64 | 63.51 | 0.00 | 0.00 |
| July | 151.82 | 4.52 | 66.19 | 2.47 | 63.72 | 0.00 | 0.00 |
| August | 136.17 | 8.10 | 59.52 | 0.61 | 58.91 | 0.00 | 0.00 |
| September | 107.11 | 14.77 | 51.25 | 0.01 | 51.24 | 0.00 | 0.00 |
| October | 84.63 | 34.40 | 44.52 | 0.00 | 44.52 | 0.00 | 0.00 |
| November | 33.82 | 93.55 | 33.80 | 0.00 | 33.80 | 0.00 | 0.00 |
| December | 22.33 | 129.23 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Annual Sum or Average | 82.43 | 62.28 | 48.68 | 0.86 | 47.82 | 0.00 | 0.00 |
| Minimum of Months | 19.70 | 4.52 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Maximum of Months | 154.70 | 151.78 | 68.16 | 4.64 | 63.72 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 268.35 | 134.42 | 187.72 | 133.34 | 54.38 | 0.00 | 0.00 |
| February | 252.29 | 115.61 | 173.17 | 112.51 | 60.65 | 0.00 | 0.00 |
| March | 161.35 | 102.50 | 108.35 | 48.13 | 60.23 | 0.00 | 0.00 |
| April | 138.73 | 62.91 | 83.19 | 20.88 | 62.31 | 0.00 | 0.00 |
| May | 137.44 | 11.25 | 62.38 | 2.83 | 59.55 | 0.00 | 0.00 |
| June | 140.43 | 8.83 | 61.48 | 0.64 | 60.84 | 0.00 | 0.00 |
| July | 148.86 | 4.43 | 64.33 | 1.21 | 63.12 | 0.00 | 0.00 |
| August | 170.38 | 8.61 | 75.00 | 8.43 | 66.57 | 0.00 | 0.00 |
| September | 189.62 | 15.29 | 91.98 | 25.14 | 66.84 | 0.00 | 0.00 |
| October | 258.90 | 34.29 | 138.27 | 70.82 | 67.46 | 0.00 | 0.00 |
| November | 282.55 | 85.69 | 179.89 | 124.07 | 55.82 | 0.00 | 0.00 |
| December | 276.86 | 117.85 | 184.96 | 132.74 | 52.21 | 0.00 | 0.00 |
| Annual Sum or Average | 201.89 | 58.17 | 117.25 | 56.42 | 60.83 | 0.00 | 0.00 |
| Minimum of Months | 137.44 | 4.43 | 61.48 | 0.64 | 52.21 | 0.00 | 0.00 |
| Maximum of Months | 282.55 | 134.42 | 187.72 | 133.34 | 67.46 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 268.33 | 134.42 | 187.72 | 133.34 | 54.38 | 0.00 | 0.00 |
| February | 252.27 | 115.59 | 173.17 | 112.51 | 60.65 | 0.00 | 0.00 |
| March | 161.30 | 102.50 | 108.35 | 48.13 | 60.23 | 0.00 | 0.00 |
| April | 138.69 | 62.91 | 83.19 | 20.88 | 62.31 | 0.00 | 0.00 |
| May | 137.42 | 11.25 | 62.38 | 2.83 | 59.55 | 0.00 | 0.00 |
| June | 140.42 | 8.82 | 61.48 | 0.64 | 60.84 | 0.00 | 0.00 |
| July | 148.85 | 4.43 | 64.33 | 1.21 | 63.12 | 0.00 | 0.00 |
| August | 170.37 | 8.60 | 75.00 | 8.43 | 66.57 | 0.00 | 0.00 |
| September | 189.61 | 15.28 | 91.98 | 25.14 | 66.84 | 0.00 | 0.00 |
| October | 258.89 | 34.28 | 138.27 | 70.82 | 67.46 | 0.00 | 0.00 |
| November | 282.52 | 85.68 | 179.89 | 124.07 | 55.82 | 0.00 | 0.00 |
| December | 276.86 | 117.82 | 184.96 | 132.74 | 52.21 | 0.00 | 0.00 |
| Annual Sum or Average | 201.87 | 58.16 | 117.25 | 56.42 | 60.83 | 0.00 | 0.00 |
| Minimum of Months | 137.42 | 4.43 | 61.48 | 0.64 | 52.21 | 0.00 | 0.00 |
| Maximum of Months | 282.52 | 134.42 | 187.72 | 133.34 | 67.46 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 338.55 | 200.32 | 246.72 | 165.21 | 81.51 | 0.00 | 0.00 |
| February | 334.64 | 175.39 | 239.93 | 146.26 | 93.67 | 0.00 | 0.00 |
| March | 248.79 | 152.38 | 174.28 | 77.29 | 96.98 | 0.00 | 0.00 |
| April | 261.51 | 98.85 | 164.95 | 58.43 | 106.53 | 0.00 | 0.00 |
| May | 266.14 | 19.38 | 130.49 | 25.00 | 105.49 | 0.00 | 0.00 |
| June | 286.60 | 15.32 | 137.21 | 27.25 | 109.96 | 0.00 | 0.00 |
| July | 283.50 | 7.89 | 133.33 | 20.33 | 113.00 | 0.00 | 0.00 |
| August | 305.31 | 14.95 | 144.77 | 29.70 | 115.06 | 0.00 | 0.00 |
| September | 306.64 | 26.08 | 156.30 | 47.22 | 109.08 | 0.00 | 0.00 |
| October | 371.73 | 55.65 | 203.95 | 99.13 | 104.82 | 0.00 | 0.00 |
| November | 357.33 | 134.44 | 236.28 | 152.40 | 83.88 | 0.00 | 0.00 |
| December | 345.25 | 175.71 | 239.21 | 161.59 | 77.62 | 0.00 | 0.00 |
| Annual Sum or Average | 308.68 | 89.22 | 183.60 | 83.78 | 99.82 | 0.00 | 0.00 |
| Minimum of Months | 248.79 | 7.89 | 130.49 | 20.33 | 77.62 | 0.00 | 0.00 |
| Maximum of Months | 371.73 | 200.32 | 246.72 | 165.21 | 115.06 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 94.78 | 203.19 | 91.80 | 31.87 | 59.93 | 0.00 | 0.00 |
| February | 115.22 | 178.03 | 105.46 | 33.75 | 71.72 | 0.00 | 0.00 |
| March | 133.95 | 153.35 | 110.82 | 29.17 | 81.65 | 0.00 | 0.00 |
| April | 196.62 | 98.38 | 134.88 | 37.87 | 97.02 | 0.00 | 0.00 |
| May | 259.84 | 18.77 | 128.23 | 24.43 | 103.80 | 0.00 | 0.00 |
| June | 300.50 | 14.74 | 143.89 | 31.26 | 112.63 | 0.00 | 0.00 |
| July | 286.45 | 8.01 | 135.19 | 21.59 | 113.60 | 0.00 | 0.00 |
| August | 271.79 | 14.44 | 129.29 | 21.89 | 107.40 | 0.00 | 0.00 |
| September | 225.56 | 25.49 | 115.57 | 22.09 | 93.48 | 0.00 | 0.00 |
| October | 200.77 | 54.77 | 110.20 | 28.32 | 81.88 | 0.00 | 0.00 |
| November | 115.85 | 136.71 | 90.19 | 28.33 | 61.86 | 0.00 | 0.00 |
| December | 96.05 | 174.60 | 84.75 | 28.85 | 55.90 | 0.00 | 0.00 |
| Annual Sum or Average | 191.88 | 89.55 | 115.03 | 28.22 | 86.81 | 0.00 | 0.00 |
| Minimum of Months | 94.78 | 8.01 | 84.75 | 21.59 | 55.90 | 0.00 | 0.00 |
| Maximum of Months | 300.50 | 203.19 | 143.89 | 37.87 | 113.60 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 329.73 | 198.05 | 243.50 | 161.86 | 81.64 | 0.00 | 0.00 |
| February | 323.58 | 172.53 | 234.88 | 142.19 | 92.69 | 0.00 | 0.00 |
| March | 254.42 | 148.55 | 181.13 | 83.17 | 97.96 | 0.00 | 0.00 |
| April | 254.06 | 95.89 | 163.24 | 57.14 | 106.10 | 0.00 | 0.00 |
| May | 288.45 | 18.22 | 144.73 | 38.56 | 106.16 | 0.00 | 0.00 |
| June | 299.04 | 14.39 | 144.95 | 33.75 | 111.20 | 0.00 | 0.00 |
| July | 303.47 | 7.56 | 144.86 | 30.72 | 114.14 | 0.00 | 0.00 |
| August | 311.32 | 14.14 | 149.18 | 33.91 | 115.27 | 0.00 | 0.00 |
| September | 307.47 | 25.16 | 157.59 | 47.65 | 109.93 | 0.00 | 0.00 |
| October | 367.49 | 53.92 | 203.34 | 98.35 | 104.99 | 0.00 | 0.00 |
| November | 355.43 | 132.68 | 237.37 | 153.38 | 83.99 | 0.00 | 0.00 |
| December | 328.16 | 174.58 | 230.25 | 153.28 | 76.96 | 0.00 | 0.00 |
| Annual Sum or Average | 310.18 | 87.51 | 185.97 | 85.85 | 100.12 | 0.00 | 0.00 |
| Minimum of Months | 254.06 | 7.56 | 144.73 | 30.72 | 76.96 | 0.00 | 0.00 |
| Maximum of Months | 367.49 | 198.05 | 243.50 | 161.86 | 115.27 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 82.32 | 195.42 | 88.58 | 28.52 | 60.06 | 0.00 | 0.00 |
| February | 100.34 | 170.73 | 100.41 | 29.68 | 70.73 | 0.00 | 0.00 |
| March | 137.72 | 146.90 | 117.67 | 35.05 | 82.63 | 0.00 | 0.00 |
| April | 189.45 | 95.38 | 133.17 | 36.58 | 96.60 | 0.00 | 0.00 |
| May | 282.71 | 18.14 | 142.47 | 38.00 | 104.47 | 0.00 | 0.00 |
| June | 313.32 | 14.16 | 151.63 | 37.76 | 113.87 | 0.00 | 0.00 |
| July | 306.45 | 7.68 | 146.73 | 31.98 | 114.74 | 0.00 | 0.00 |
| August | 277.92 | 13.73 | 133.70 | 26.10 | 107.61 | 0.00 | 0.00 |
| September | 226.34 | 24.53 | 116.86 | 22.52 | 94.34 | 0.00 | 0.00 |
| October | 196.01 | 52.05 | 109.58 | 27.53 | 82.05 | 0.00 | 0.00 |
| November | 109.11 | 129.74 | 91.27 | 29.31 | 61.96 | 0.00 | 0.00 |
| December | 77.09 | 170.56 | 75.78 | 20.54 | 55.24 | 0.00 | 0.00 |
| Annual Sum or Average | 192.12 | 86.12 | 117.40 | 30.29 | 87.11 | 0.00 | 0.00 |
| Minimum of Months | 77.09 | 7.68 | 75.78 | 20.54 | 55.24 | 0.00 | 0.00 |
| Maximum of Months | 313.32 | 195.42 | 151.63 | 38.00 | 114.74 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 22.97 | 131.04 | 32.80 | 0.00 | 32.80 | 0.00 | 0.00 |
| February | 30.27 | 114.28 | 38.70 | 0.00 | 38.70 | 0.00 | 0.00 |
| March | 44.98 | 96.99 | 44.90 | 0.00 | 44.90 | 0.00 | 0.00 |
| April | 70.77 | 60.65 | 53.12 | 0.31 | 52.81 | 0.00 | 0.00 |
| May | 127.84 | 10.86 | 60.12 | 2.26 | 57.86 | 0.00 | 0.00 |
| June | 150.90 | 8.41 | 68.16 | 4.64 | 63.51 | 0.00 | 0.00 |
| July | 147.88 | 4.61 | 66.19 | 2.47 | 63.72 | 0.00 | 0.00 |
| August | 132.69 | 8.26 | 59.52 | 0.61 | 58.91 | 0.00 | 0.00 |
| September | 104.35 | 15.08 | 51.25 | 0.01 | 51.24 | 0.00 | 0.00 |
| October | 82.89 | 33.39 | 44.52 | 0.00 | 44.52 | 0.00 | 0.00 |
| November | 34.89 | 87.01 | 33.80 | 0.00 | 33.80 | 0.00 | 0.00 |
| December | 24.63 | 112.48 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Annual Sum or Average | 81.58 | 56.61 | 48.68 | 0.86 | 47.82 | 0.00 | 0.00 |
| Minimum of Months | 22.97 | 4.61 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Maximum of Months | 150.90 | 131.04 | 68.16 | 4.64 | 63.72 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 22.90 | 130.92 | 32.80 | 0.00 | 32.80 | 0.00 | 0.00 |
| February | 30.18 | 114.17 | 38.70 | 0.00 | 38.70 | 0.00 | 0.00 |
| March | 44.84 | 96.93 | 44.90 | 0.00 | 44.90 | 0.00 | 0.00 |
| April | 70.64 | 60.60 | 53.12 | 0.31 | 52.81 | 0.00 | 0.00 |
| May | 127.81 | 10.85 | 60.12 | 2.26 | 57.86 | 0.00 | 0.00 |
| June | 150.88 | 8.40 | 68.16 | 4.64 | 63.51 | 0.00 | 0.00 |
| July | 147.86 | 4.61 | 66.19 | 2.47 | 63.72 | 0.00 | 0.00 |
| August | 132.68 | 8.24 | 59.52 | 0.61 | 58.91 | 0.00 | 0.00 |
| September | 104.34 | 15.06 | 51.25 | 0.01 | 51.24 | 0.00 | 0.00 |
| October | 82.85 | 33.33 | 44.52 | 0.00 | 44.52 | 0.00 | 0.00 |
| November | 34.78 | 86.95 | 33.80 | 0.00 | 33.80 | 0.00 | 0.00 |
| December | 24.59 | 112.33 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Annual Sum or Average | 81.52 | 56.55 | 48.68 | 0.86 | 47.82 | 0.00 | 0.00 |
| Minimum of Months | 22.90 | 4.61 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Maximum of Months | 150.88 | 130.92 | 68.16 | 4.64 | 63.72 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 270.84 | 123.54 | 187.72 | 133.34 | 54.38 | 0.00 | 0.00 |
| February | 253.24 | 107.83 | 173.17 | 112.51 | 60.65 | 0.00 | 0.00 |
| March | 161.83 | 94.77 | 108.35 | 48.13 | 60.23 | 0.00 | 0.00 |
| April | 136.60 | 61.47 | 83.19 | 20.88 | 62.31 | 0.00 | 0.00 |
| May | 134.05 | 11.31 | 62.38 | 2.83 | 59.55 | 0.00 | 0.00 |
| June | 136.71 | 8.92 | 61.48 | 0.64 | 60.84 | 0.00 | 0.00 |
| July | 144.92 | 4.54 | 64.33 | 1.21 | 63.12 | 0.00 | 0.00 |
| August | 166.60 | 8.74 | 75.00 | 8.43 | 66.57 | 0.00 | 0.00 |
| September | 186.30 | 15.48 | 91.98 | 25.14 | 66.84 | 0.00 | 0.00 |
| October | 255.76 | 33.50 | 138.27 | 70.82 | 67.46 | 0.00 | 0.00 |
| November | 281.23 | 82.20 | 179.89 | 124.07 | 55.82 | 0.00 | 0.00 |
| December | 277.78 | 108.78 | 184.96 | 132.74 | 52.21 | 0.00 | 0.00 |
| Annual Sum or Average | 200.22 | 54.80 | 117.25 | 56.42 | 60.83 | 0.00 | 0.00 |
| Minimum of Months | 134.05 | 4.54 | 61.48 | 0.64 | 52.21 | 0.00 | 0.00 |
| Maximum of Months | 281.23 | 123.54 | 187.72 | 133.34 | 67.46 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 270.73 | 123.49 | 187.72 | 133.34 | 54.38 | 0.00 | 0.00 |
| February | 253.14 | 107.75 | 173.17 | 112.51 | 60.65 | 0.00 | 0.00 |
| March | 161.68 | 94.76 | 108.35 | 48.13 | 60.23 | 0.00 | 0.00 |
| April | 136.49 | 61.43 | 83.19 | 20.88 | 62.31 | 0.00 | 0.00 |
| May | 134.01 | 11.30 | 62.38 | 2.83 | 59.55 | 0.00 | 0.00 |
| June | 136.68 | 8.91 | 61.48 | 0.64 | 60.84 | 0.00 | 0.00 |
| July | 144.89 | 4.53 | 64.33 | 1.21 | 63.12 | 0.00 | 0.00 |
| August | 166.59 | 8.73 | 75.00 | 8.43 | 66.57 | 0.00 | 0.00 |
| September | 186.28 | 15.46 | 91.98 | 25.14 | 66.84 | 0.00 | 0.00 |
| October | 255.73 | 33.46 | 138.27 | 70.82 | 67.46 | 0.00 | 0.00 |
| November | 281.15 | 82.16 | 179.89 | 124.07 | 55.82 | 0.00 | 0.00 |
| December | 277.74 | 108.70 | 184.96 | 132.74 | 52.21 | 0.00 | 0.00 |
| Annual Sum or Average | 200.16 | 54.77 | 117.25 | 56.42 | 60.83 | 0.00 | 0.00 |
| Minimum of Months | 134.01 | 4.53 | 61.48 | 0.64 | 52.21 | 0.00 | 0.00 |
| Maximum of Months | 281.15 | 123.49 | 187.72 | 133.34 | 67.46 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 15.43 | 21.46 | 13.38 | 6.84 | 6.54 | 0.00 | 0.00 |
| February | 17.81 | 18.68 | 14.81 | 7.12 | 7.69 | 0.00 | 0.00 |
| March | 22.94 | 16.05 | 17.46 | 8.41 | 9.05 | 0.00 | 0.00 |
| April | 28.41 | 10.82 | 19.21 | 8.70 | 10.51 | 0.00 | 0.00 |
| May | 35.71 | 3.07 | 19.76 | 8.57 | 11.19 | 0.00 | 0.00 |
| June | 37.58 | 2.65 | 20.03 | 7.95 | 12.08 | 0.00 | 0.00 |
| July | 36.37 | 1.76 | 19.33 | 7.08 | 12.24 | 0.00 | 0.00 |
| August | 33.23 | 2.54 | 17.80 | 6.11 | 11.68 | 0.00 | 0.00 |
| September | 27.92 | 3.83 | 15.74 | 5.40 | 10.34 | 0.00 | 0.00 |
| October | 26.09 | 6.77 | 15.61 | 6.61 | 9.01 | 0.00 | 0.00 |
| November | 18.29 | 14.75 | 13.79 | 7.03 | 6.76 | 0.00 | 0.00 |
| December | 12.77 | 19.13 | 10.87 | 4.93 | 5.94 | 0.00 | 0.00 |
| Annual Sum or Average | 26.09 | 10.08 | 16.49 | 7.06 | 9.43 | 0.00 | 0.00 |
| Minimum of Months | 12.77 | 1.76 | 10.87 | 4.93 | 5.94 | 0.00 | 0.00 |
| Maximum of Months | 37.58 | 21.46 | 20.03 | 8.70 | 12.24 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 44.92 | 66.95 | 39.86 | 20.38 | 19.48 | 0.00 | 0.00 |
| February | 53.02 | 56.37 | 44.10 | 21.21 | 22.89 | 0.00 | 0.00 |
| March | 68.61 | 48.31 | 52.01 | 25.05 | 26.96 | 0.00 | 0.00 |
| April | 85.04 | 32.31 | 57.21 | 25.92 | 31.29 | 0.00 | 0.00 |
| May | 104.05 | 11.64 | 58.85 | 25.54 | 33.31 | 0.00 | 0.00 |
| June | 108.86 | 10.60 | 59.65 | 23.67 | 35.99 | 0.00 | 0.00 |
| July | 104.59 | 8.19 | 57.56 | 21.09 | 36.46 | 0.00 | 0.00 |
| August | 95.14 | 10.95 | 53.01 | 18.21 | 34.80 | 0.00 | 0.00 |
| September | 80.04 | 15.10 | 46.89 | 16.09 | 30.80 | 0.00 | 0.00 |
| October | 75.35 | 23.95 | 46.50 | 19.68 | 26.82 | 0.00 | 0.00 |
| November | 53.07 | 46.83 | 41.08 | 20.95 | 20.13 | 0.00 | 0.00 |
| December | 36.64 | 61.09 | 32.37 | 14.68 | 17.69 | 0.00 | 0.00 |
| Annual Sum or Average | 75.90 | 32.57 | 49.11 | 21.03 | 28.08 | 0.00 | 0.00 |
| Minimum of Months | 36.64 | 8.19 | 32.37 | 14.68 | 17.69 | 0.00 | 0.00 |
| Maximum of Months | 108.86 | 66.95 | 59.65 | 25.92 | 36.46 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 14.27 | 24.23 | 13.38 | 6.84 | 6.54 | 0.00 | 0.00 |
| February | 16.87 | 20.62 | 14.81 | 7.12 | 7.69 | 0.00 | 0.00 |
| March | 22.15 | 17.63 | 17.46 | 8.41 | 9.05 | 0.00 | 0.00 |
| April | 28.28 | 11.13 | 19.21 | 8.70 | 10.51 | 0.00 | 0.00 |
| May | 36.26 | 2.99 | 19.76 | 8.57 | 11.19 | 0.00 | 0.00 |
| June | 38.20 | 2.55 | 20.03 | 7.95 | 12.08 | 0.00 | 0.00 |
| July | 37.05 | 1.66 | 19.33 | 7.08 | 12.24 | 0.00 | 0.00 |
| August | 33.85 | 2.44 | 17.80 | 6.11 | 11.68 | 0.00 | 0.00 |
| September | 28.37 | 3.77 | 15.74 | 5.40 | 10.34 | 0.00 | 0.00 |
| October | 26.30 | 6.93 | 15.61 | 6.61 | 9.01 | 0.00 | 0.00 |
| November | 17.69 | 15.78 | 13.79 | 7.03 | 6.76 | 0.00 | 0.00 |
| December | 11.93 | 21.55 | 10.87 | 4.93 | 5.94 | 0.00 | 0.00 |
| Annual Sum or Average | 25.99 | 10.89 | 16.49 | 7.06 | 9.43 | 0.00 | 0.00 |
| Minimum of Months | 11.93 | 1.66 | 10.87 | 4.93 | 5.94 | 0.00 | 0.00 |
| Maximum of Months | 38.20 | 24.23 | 20.03 | 8.70 | 12.24 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.904687E+09 | 0.588591E+09 | 0.660812E+09 | 0.442488E+09 | 0.218323E+09 | 0.00 | 0.00 |
| February | 0.820990E+09 | 0.446766E+09 | 0.580447E+09 | 0.353833E+09 | 0.226614E+09 | 0.00 | 0.00 |
| March | 0.684547E+09 | 0.424359E+09 | 0.466782E+09 | 0.207026E+09 | 0.259756E+09 | 0.00 | 0.00 |
| April | 0.705259E+09 | 0.251506E+09 | 0.427561E+09 | 0.151447E+09 | 0.276114E+09 | 0.00 | 0.00 |
| May | 0.734999E+09 | 50843241.19 | 0.349506E+09 | 66949106.90 | 0.282557E+09 | 0.00 | 0.00 |
| June | 0.763681E+09 | 40092202.51 | 0.355648E+09 | 70640573.72 | 0.285008E+09 | 0.00 | 0.00 |
| July | 0.776482E+09 | 23225719.09 | 0.357116E+09 | 54449156.63 | 0.302666E+09 | 0.00 | 0.00 |
| August | 0.829490E+09 | 46118008.63 | 0.387742E+09 | 79557474.92 | 0.308184E+09 | 0.00 | 0.00 |
| September | 0.805292E+09 | 76068383.38 | 0.405127E+09 | 0.122402E+09 | 0.282725E+09 | 0.00 | 0.00 |
| October | 0.100673E+10 | 0.162931E+09 | 0.546269E+09 | 0.265519E+09 | 0.280750E+09 | 0.00 | 0.00 |
| November | 0.932894E+09 | 0.373074E+09 | 0.612449E+09 | 0.395029E+09 | 0.217420E+09 | 0.00 | 0.00 |
| December | 0.924041E+09 | 0.520234E+09 | 0.640704E+09 | 0.432805E+09 | 0.207899E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.988909E+10 | 0.300381E+10 | 0.579016E+10 | 0.264215E+10 | 0.314802E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.684547E+09 | 23225719.09 | 0.349506E+09 | 54449156.63 | 0.207899E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.100673E+10 | 0.588591E+09 | 0.660812E+09 | 0.442488E+09 | 0.308184E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.245017E+09 | 0.602291E+09 | 0.245872E+09 | 85347902.52 | 0.160524E+09 | 0.00 | 0.00 |
| February | 0.285764E+09 | 0.449130E+09 | 0.255130E+09 | 81636932.67 | 0.173493E+09 | 0.00 | 0.00 |
| March | 0.373067E+09 | 0.420889E+09 | 0.296831E+09 | 78133351.41 | 0.218698E+09 | 0.00 | 0.00 |
| April | 0.535281E+09 | 0.246602E+09 | 0.349621E+09 | 98146306.07 | 0.251475E+09 | 0.00 | 0.00 |
| May | 0.717741E+09 | 49108716.79 | 0.343458E+09 | 65435817.29 | 0.278022E+09 | 0.00 | 0.00 |
| June | 0.799855E+09 | 38860666.70 | 0.372956E+09 | 81021666.15 | 0.291935E+09 | 0.00 | 0.00 |
| July | 0.784377E+09 | 23522335.98 | 0.362101E+09 | 57826611.54 | 0.304275E+09 | 0.00 | 0.00 |
| August | 0.738027E+09 | 44497490.03 | 0.346292E+09 | 58621405.29 | 0.287670E+09 | 0.00 | 0.00 |
| September | 0.592003E+09 | 73577896.07 | 0.299566E+09 | 57267252.25 | 0.242299E+09 | 0.00 | 0.00 |
| October | 0.541017E+09 | 0.161207E+09 | 0.295155E+09 | 75844789.61 | 0.219310E+09 | 0.00 | 0.00 |
| November | 0.293739E+09 | 0.390456E+09 | 0.233760E+09 | 73426852.63 | 0.160334E+09 | 0.00 | 0.00 |
| December | 0.245645E+09 | 0.534080E+09 | 0.226985E+09 | 77267943.06 | 0.149717E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.615153E+10 | 0.303422E+10 | 0.362773E+10 | 0.889977E+09 | 0.273775E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.245017E+09 | 23522335.98 | 0.226985E+09 | 57267252.25 | 0.149717E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.799855E+09 | 0.602291E+09 | 0.372956E+09 | 98146306.07 | 0.304275E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.882539E+09 | 0.597901E+09 | 0.652182E+09 | 0.433521E+09 | 0.218661E+09 | 0.00 | 0.00 |
| February | 0.799053E+09 | 0.451003E+09 | 0.568225E+09 | 0.343994E+09 | 0.224230E+09 | 0.00 | 0.00 |
| March | 0.697608E+09 | 0.433134E+09 | 0.485130E+09 | 0.222765E+09 | 0.262366E+09 | 0.00 | 0.00 |
| April | 0.669394E+09 | 0.284426E+09 | 0.423125E+09 | 0.148110E+09 | 0.275015E+09 | 0.00 | 0.00 |
| May | 0.733755E+09 | 0.120433E+09 | 0.387632E+09 | 0.103282E+09 | 0.284350E+09 | 0.00 | 0.00 |
| June | 0.731390E+09 | 0.110366E+09 | 0.375710E+09 | 87483016.42 | 0.288227E+09 | 0.00 | 0.00 |
| July | 0.738813E+09 | 98730070.79 | 0.388006E+09 | 82288759.55 | 0.305717E+09 | 0.00 | 0.00 |
| August | 0.773672E+09 | 0.127784E+09 | 0.399556E+09 | 90829998.97 | 0.308726E+09 | 0.00 | 0.00 |
| September | 0.746138E+09 | 0.162319E+09 | 0.408467E+09 | 0.123518E+09 | 0.284949E+09 | 0.00 | 0.00 |
| October | 0.950231E+09 | 0.250644E+09 | 0.544624E+09 | 0.263420E+09 | 0.281204E+09 | 0.00 | 0.00 |
| November | 0.917250E+09 | 0.421461E+09 | 0.615270E+09 | 0.397572E+09 | 0.217698E+09 | 0.00 | 0.00 |
| December | 0.872569E+09 | 0.550714E+09 | 0.616689E+09 | 0.410556E+09 | 0.206133E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.951241E+10 | 0.360891E+10 | 0.586462E+10 | 0.270734E+10 | 0.315728E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.669394E+09 | 98730070.79 | 0.375710E+09 | 82288759.55 | 0.206133E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.950231E+09 | 0.597901E+09 | 0.652182E+09 | 0.433521E+09 | 0.308726E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.207318E+09 | 0.580549E+09 | 0.237242E+09 | 76380900.21 | 0.160861E+09 | 0.00 | 0.00 |
| February | 0.246572E+09 | 0.430582E+09 | 0.242908E+09 | 71797887.95 | 0.171110E+09 | 0.00 | 0.00 |
| March | 0.382384E+09 | 0.402639E+09 | 0.315179E+09 | 93871658.47 | 0.221307E+09 | 0.00 | 0.00 |
| April | 0.517054E+09 | 0.238222E+09 | 0.345185E+09 | 94809146.46 | 0.250376E+09 | 0.00 | 0.00 |
| May | 0.780750E+09 | 48210756.98 | 0.381584E+09 | 0.101769E+09 | 0.279815E+09 | 0.00 | 0.00 |
| June | 0.833887E+09 | 37829336.66 | 0.393019E+09 | 97864108.85 | 0.295155E+09 | 0.00 | 0.00 |
| July | 0.838379E+09 | 23027196.85 | 0.392991E+09 | 85666214.46 | 0.307325E+09 | 0.00 | 0.00 |
| August | 0.754825E+09 | 42903025.88 | 0.358106E+09 | 69893929.35 | 0.288213E+09 | 0.00 | 0.00 |
| September | 0.594438E+09 | 71355154.13 | 0.302906E+09 | 58382762.56 | 0.244523E+09 | 0.00 | 0.00 |
| October | 0.528810E+09 | 0.154597E+09 | 0.293509E+09 | 73745867.93 | 0.219764E+09 | 0.00 | 0.00 |
| November | 0.273781E+09 | 0.369069E+09 | 0.236582E+09 | 75969936.22 | 0.160612E+09 | 0.00 | 0.00 |
| December | 0.192011E+09 | 0.521303E+09 | 0.202969E+09 | 55018271.94 | 0.147951E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.615021E+10 | 0.292029E+10 | 0.370218E+10 | 0.955170E+09 | 0.274701E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.192011E+09 | 23027196.85 | 0.202969E+09 | 55018271.94 | 0.147951E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.838379E+09 | 0.580549E+09 | 0.393019E+09 | 0.101769E+09 | 0.307325E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 55575001.75 | 0.395926E+09 | 87851305.19 | 0.00 | 87851305.19 | 0.00 | 0.00 |
| February | 73764080.35 | 0.293695E+09 | 93613281.56 | 0.00 | 93613281.56 | 0.00 | 0.00 |
| March | 0.123668E+09 | 0.270141E+09 | 0.120260E+09 | 5622.98 | 0.120255E+09 | 0.00 | 0.00 |
| April | 0.193677E+09 | 0.152408E+09 | 0.137691E+09 | 814454.99 | 0.136876E+09 | 0.00 | 0.00 |
| May | 0.352343E+09 | 28829119.31 | 0.161025E+09 | 6063506.41 | 0.154962E+09 | 0.00 | 0.00 |
| June | 0.400780E+09 | 22323626.84 | 0.176659E+09 | 12028244.03 | 0.164631E+09 | 0.00 | 0.00 |
| July | 0.404102E+09 | 13325998.54 | 0.177281E+09 | 6616296.66 | 0.170665E+09 | 0.00 | 0.00 |
| August | 0.360040E+09 | 24661024.80 | 0.159426E+09 | 1641530.34 | 0.157785E+09 | 0.00 | 0.00 |
| September | 0.273782E+09 | 42242122.92 | 0.132846E+09 | 25838.56 | 0.132820E+09 | 0.00 | 0.00 |
| October | 0.223069E+09 | 96339235.55 | 0.119234E+09 | 0.00 | 0.119234E+09 | 0.00 | 0.00 |
| November | 86913228.58 | 0.243436E+09 | 87597669.79 | 0.00 | 87597669.79 | 0.00 | 0.00 |
| December | 59977560.20 | 0.343669E+09 | 81667786.01 | 0.00 | 81667786.01 | 0.00 | 0.00 |
| Annual Sum or Average | 0.260769E+10 | 0.192700E+10 | 0.153515E+10 | 27195493.98 | 0.150796E+10 | 0.00 | 0.00 |
| Minimum of Months | 55575001.75 | 13325998.54 | 81667786.01 | 0.00 | 81667786.01 | 0.00 | 0.00 |
| Maximum of Months | 0.404102E+09 | 0.395926E+09 | 0.177281E+09 | 12028244.03 | 0.170665E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 55525991.82 | 0.395961E+09 | 87851305.19 | 0.00 | 87851305.19 | 0.00 | 0.00 |
| February | 73705686.65 | 0.293704E+09 | 93613281.56 | 0.00 | 93613281.56 | 0.00 | 0.00 |
| March | 0.123546E+09 | 0.270206E+09 | 0.120260E+09 | 5622.98 | 0.120255E+09 | 0.00 | 0.00 |
| April | 0.193591E+09 | 0.152401E+09 | 0.137691E+09 | 814454.99 | 0.136876E+09 | 0.00 | 0.00 |
| May | 0.352287E+09 | 28835945.43 | 0.161025E+09 | 6063506.41 | 0.154962E+09 | 0.00 | 0.00 |
| June | 0.400743E+09 | 22321496.60 | 0.176659E+09 | 12028244.03 | 0.164631E+09 | 0.00 | 0.00 |
| July | 0.404053E+09 | 13330671.78 | 0.177281E+09 | 6616296.66 | 0.170665E+09 | 0.00 | 0.00 |
| August | 0.360019E+09 | 24650619.40 | 0.159426E+09 | 1641530.34 | 0.157785E+09 | 0.00 | 0.00 |
| September | 0.273769E+09 | 42227322.26 | 0.132846E+09 | 25838.56 | 0.132820E+09 | 0.00 | 0.00 |
| October | 0.223050E+09 | 96287100.74 | 0.119234E+09 | 0.00 | 0.119234E+09 | 0.00 | 0.00 |
| November | 86857538.28 | 0.243425E+09 | 87597669.79 | 0.00 | 87597669.79 | 0.00 | 0.00 |
| December | 59990660.84 | 0.343498E+09 | 81667786.01 | 0.00 | 81667786.01 | 0.00 | 0.00 |
| Annual Sum or Average | 0.260714E+10 | 0.192685E+10 | 0.153515E+10 | 27195493.98 | 0.150796E+10 | 0.00 | 0.00 |
| Minimum of Months | 55525991.82 | 13330671.78 | 81667786.01 | 0.00 | 81667786.01 | 0.00 | 0.00 |
| Maximum of Months | 0.404053E+09 | 0.395961E+09 | 0.177281E+09 | 12028244.03 | 0.170665E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.725140E+09 | 0.357143E+09 | 0.502791E+09 | 0.357141E+09 | 0.145651E+09 | 0.00 | 0.00 |
| February | 0.618193E+09 | 0.273454E+09 | 0.418930E+09 | 0.272196E+09 | 0.146733E+09 | 0.00 | 0.00 |
| March | 0.440837E+09 | 0.264884E+09 | 0.290211E+09 | 0.128898E+09 | 0.161313E+09 | 0.00 | 0.00 |
| April | 0.366387E+09 | 0.156662E+09 | 0.215630E+09 | 54115104.10 | 0.161515E+09 | 0.00 | 0.00 |
| May | 0.369167E+09 | 30171345.78 | 0.167073E+09 | 7576796.02 | 0.159496E+09 | 0.00 | 0.00 |
| June | 0.363729E+09 | 23462162.74 | 0.159351E+09 | 1647151.60 | 0.157704E+09 | 0.00 | 0.00 |
| July | 0.395912E+09 | 13134230.75 | 0.172296E+09 | 3238841.76 | 0.169057E+09 | 0.00 | 0.00 |
| August | 0.452138E+09 | 26110707.25 | 0.200876E+09 | 22577599.97 | 0.178298E+09 | 0.00 | 0.00 |
| September | 0.488613E+09 | 43984652.08 | 0.238407E+09 | 65161043.25 | 0.173246E+09 | 0.00 | 0.00 |
| October | 0.692005E+09 | 96274305.92 | 0.370348E+09 | 0.189674E+09 | 0.180674E+09 | 0.00 | 0.00 |
| November | 0.734369E+09 | 0.223974E+09 | 0.466286E+09 | 0.321602E+09 | 0.144684E+09 | 0.00 | 0.00 |
| December | 0.745331E+09 | 0.315560E+09 | 0.495387E+09 | 0.355537E+09 | 0.139850E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.639182E+10 | 0.182481E+10 | 0.369759E+10 | 0.177937E+10 | 0.191822E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.363729E+09 | 13134230.75 | 0.159351E+09 | 1647151.60 | 0.139850E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.745331E+09 | 0.357143E+09 | 0.502791E+09 | 0.357141E+09 | 0.180674E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.724919E+09 | 0.357376E+09 | 0.502791E+09 | 0.357141E+09 | 0.145651E+09 | 0.00 | 0.00 |
| February | 0.618177E+09 | 0.273370E+09 | 0.418930E+09 | 0.272196E+09 | 0.146733E+09 | 0.00 | 0.00 |
| March | 0.440431E+09 | 0.265280E+09 | 0.290211E+09 | 0.128898E+09 | 0.161313E+09 | 0.00 | 0.00 |
| April | 0.365396E+09 | 0.157782E+09 | 0.215630E+09 | 54115104.10 | 0.161515E+09 | 0.00 | 0.00 |
| May | 0.366959E+09 | 31761581.03 | 0.167073E+09 | 7576796.02 | 0.159496E+09 | 0.00 | 0.00 |
| June | 0.361453E+09 | 24903939.13 | 0.159351E+09 | 1647151.60 | 0.157704E+09 | 0.00 | 0.00 |
| July | 0.392863E+09 | 14310865.42 | 0.172296E+09 | 3238841.76 | 0.169057E+09 | 0.00 | 0.00 |
| August | 0.449679E+09 | 27699955.85 | 0.200876E+09 | 22577599.97 | 0.178298E+09 | 0.00 | 0.00 |
| September | 0.486663E+09 | 45991964.64 | 0.238407E+09 | 65161043.25 | 0.173246E+09 | 0.00 | 0.00 |
| October | 0.690222E+09 | 98382380.92 | 0.370348E+09 | 0.189674E+09 | 0.180674E+09 | 0.00 | 0.00 |
| November | 0.733474E+09 | 0.225218E+09 | 0.466286E+09 | 0.321602E+09 | 0.144684E+09 | 0.00 | 0.00 |
| December | 0.744857E+09 | 0.316221E+09 | 0.495387E+09 | 0.355537E+09 | 0.139850E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.637509E+10 | 0.183830E+10 | 0.369759E+10 | 0.177937E+10 | 0.191822E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.361453E+09 | 14310865.42 | 0.159351E+09 | 1647151.60 | 0.139850E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.744857E+09 | 0.357376E+09 | 0.502791E+09 | 0.357141E+09 | 0.180674E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.894830E+09 | 0.593939E+09 | 0.660812E+09 | 0.442488E+09 | 0.218323E+09 | 0.00 | 0.00 |
| February | 0.805939E+09 | 0.461049E+09 | 0.580447E+09 | 0.353833E+09 | 0.226614E+09 | 0.00 | 0.00 |
| March | 0.665355E+09 | 0.447395E+09 | 0.466782E+09 | 0.207026E+09 | 0.259756E+09 | 0.00 | 0.00 |
| April | 0.688796E+09 | 0.266131E+09 | 0.427561E+09 | 0.151447E+09 | 0.276114E+09 | 0.00 | 0.00 |
| May | 0.729911E+09 | 52558662.55 | 0.349506E+09 | 66949106.90 | 0.282557E+09 | 0.00 | 0.00 |
| June | 0.761311E+09 | 40165526.61 | 0.355648E+09 | 70640573.72 | 0.285008E+09 | 0.00 | 0.00 |
| July | 0.779288E+09 | 21347922.80 | 0.357116E+09 | 54449156.63 | 0.302666E+09 | 0.00 | 0.00 |
| August | 0.836776E+09 | 40301711.41 | 0.387742E+09 | 79557474.92 | 0.308184E+09 | 0.00 | 0.00 |
| September | 0.810741E+09 | 67927522.36 | 0.405127E+09 | 0.122402E+09 | 0.282725E+09 | 0.00 | 0.00 |
| October | 0.101039E+10 | 0.154536E+09 | 0.546269E+09 | 0.265519E+09 | 0.280750E+09 | 0.00 | 0.00 |
| November | 0.930733E+09 | 0.369441E+09 | 0.612449E+09 | 0.395029E+09 | 0.217420E+09 | 0.00 | 0.00 |
| December | 0.919001E+09 | 0.519624E+09 | 0.640704E+09 | 0.432805E+09 | 0.207899E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.983307E+10 | 0.303442E+10 | 0.579016E+10 | 0.264215E+10 | 0.314802E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.665355E+09 | 21347922.80 | 0.349506E+09 | 54449156.63 | 0.207899E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.101039E+10 | 0.593939E+09 | 0.660812E+09 | 0.442488E+09 | 0.308184E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.238505E+09 | 0.615457E+09 | 0.245872E+09 | 85347902.52 | 0.160524E+09 | 0.00 | 0.00 |
| February | 0.270804E+09 | 0.476730E+09 | 0.255130E+09 | 81636932.67 | 0.173493E+09 | 0.00 | 0.00 |
| March | 0.353450E+09 | 0.453077E+09 | 0.296831E+09 | 78133351.41 | 0.218698E+09 | 0.00 | 0.00 |
| April | 0.518603E+09 | 0.263568E+09 | 0.349621E+09 | 98146306.07 | 0.251475E+09 | 0.00 | 0.00 |
| May | 0.712665E+09 | 50674508.99 | 0.343458E+09 | 65435817.29 | 0.278022E+09 | 0.00 | 0.00 |
| June | 0.797608E+09 | 38627366.41 | 0.372956E+09 | 81021666.15 | 0.291935E+09 | 0.00 | 0.00 |
| July | 0.787197E+09 | 21599341.16 | 0.362101E+09 | 57826611.54 | 0.304275E+09 | 0.00 | 0.00 |
| August | 0.745922E+09 | 38751031.18 | 0.346292E+09 | 58621405.29 | 0.287670E+09 | 0.00 | 0.00 |
| September | 0.598547E+09 | 65929118.90 | 0.299566E+09 | 57267252.25 | 0.242299E+09 | 0.00 | 0.00 |
| October | 0.547140E+09 | 0.153213E+09 | 0.295155E+09 | 75844789.61 | 0.219310E+09 | 0.00 | 0.00 |
| November | 0.295083E+09 | 0.387886E+09 | 0.233760E+09 | 73426852.63 | 0.160334E+09 | 0.00 | 0.00 |
| December | 0.245354E+09 | 0.533892E+09 | 0.226985E+09 | 77267943.06 | 0.149717E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.611088E+10 | 0.309940E+10 | 0.362773E+10 | 0.889977E+09 | 0.273775E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.238505E+09 | 21599341.16 | 0.226985E+09 | 57267252.25 | 0.149717E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.797608E+09 | 0.615457E+09 | 0.372956E+09 | 98146306.07 | 0.304275E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.872627E+09 | 0.587590E+09 | 0.652182E+09 | 0.433521E+09 | 0.218661E+09 | 0.00 | 0.00 |
| February | 0.778961E+09 | 0.453700E+09 | 0.568225E+09 | 0.343994E+09 | 0.224230E+09 | 0.00 | 0.00 |
| March | 0.679833E+09 | 0.434667E+09 | 0.485130E+09 | 0.222765E+09 | 0.262366E+09 | 0.00 | 0.00 |
| April | 0.669021E+09 | 0.257244E+09 | 0.423125E+09 | 0.148110E+09 | 0.275015E+09 | 0.00 | 0.00 |
| May | 0.790790E+09 | 49696563.43 | 0.387632E+09 | 0.103282E+09 | 0.284350E+09 | 0.00 | 0.00 |
| June | 0.794091E+09 | 37883851.02 | 0.375710E+09 | 87483016.42 | 0.288227E+09 | 0.00 | 0.00 |
| July | 0.833121E+09 | 20526237.65 | 0.388006E+09 | 82288759.55 | 0.305717E+09 | 0.00 | 0.00 |
| August | 0.853234E+09 | 38332172.98 | 0.399556E+09 | 90829998.97 | 0.308726E+09 | 0.00 | 0.00 |
| September | 0.813375E+09 | 65842355.47 | 0.408467E+09 | 0.123518E+09 | 0.284949E+09 | 0.00 | 0.00 |
| October | 0.999782E+09 | 0.150245E+09 | 0.544624E+09 | 0.263420E+09 | 0.281204E+09 | 0.00 | 0.00 |
| November | 0.926566E+09 | 0.364775E+09 | 0.615270E+09 | 0.397572E+09 | 0.217698E+09 | 0.00 | 0.00 |
| December | 0.874424E+09 | 0.517520E+09 | 0.616689E+09 | 0.410556E+09 | 0.206133E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.988583E+10 | 0.297802E+10 | 0.586462E+10 | 0.270734E+10 | 0.315728E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.669021E+09 | 20526237.65 | 0.375710E+09 | 82288759.55 | 0.206133E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.999782E+09 | 0.587590E+09 | 0.652182E+09 | 0.433521E+09 | 0.308726E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.200341E+09 | 0.593579E+09 | 0.237242E+09 | 76380900.21 | 0.160861E+09 | 0.00 | 0.00 |
| February | 0.231537E+09 | 0.456908E+09 | 0.242908E+09 | 71797887.95 | 0.171110E+09 | 0.00 | 0.00 |
| March | 0.361044E+09 | 0.432744E+09 | 0.315179E+09 | 93871658.47 | 0.221307E+09 | 0.00 | 0.00 |
| April | 0.499163E+09 | 0.255109E+09 | 0.345185E+09 | 94809146.46 | 0.250376E+09 | 0.00 | 0.00 |
| May | 0.775187E+09 | 49399227.99 | 0.381584E+09 | 0.101769E+09 | 0.279815E+09 | 0.00 | 0.00 |
| June | 0.831498E+09 | 37408106.49 | 0.393019E+09 | 97864108.85 | 0.295155E+09 | 0.00 | 0.00 |
| July | 0.841190E+09 | 20905546.58 | 0.392991E+09 | 85666214.46 | 0.307325E+09 | 0.00 | 0.00 |
| August | 0.762740E+09 | 37145164.10 | 0.358106E+09 | 69893929.35 | 0.288213E+09 | 0.00 | 0.00 |
| September | 0.601079E+09 | 63768220.64 | 0.302906E+09 | 58382762.56 | 0.244523E+09 | 0.00 | 0.00 |
| October | 0.534738E+09 | 0.146526E+09 | 0.293509E+09 | 73745867.93 | 0.219764E+09 | 0.00 | 0.00 |
| November | 0.274714E+09 | 0.365965E+09 | 0.236582E+09 | 75969936.22 | 0.160612E+09 | 0.00 | 0.00 |
| December | 0.191404E+09 | 0.520857E+09 | 0.202969E+09 | 55018271.94 | 0.147951E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.610464E+10 | 0.298031E+10 | 0.370218E+10 | 0.955170E+09 | 0.274701E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.191404E+09 | 20905546.58 | 0.202969E+09 | 55018271.94 | 0.147951E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.841190E+09 | 0.593579E+09 | 0.393019E+09 | 0.101769E+09 | 0.307325E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 52820459.77 | 0.406458E+09 | 87851305.19 | 0.00 | 87851305.19 | 0.00 | 0.00 |
| February | 68403135.82 | 0.308442E+09 | 93613281.56 | 0.00 | 93613281.56 | 0.00 | 0.00 |
| March | 0.115995E+09 | 0.285898E+09 | 0.120260E+09 | 5622.98 | 0.120255E+09 | 0.00 | 0.00 |
| April | 0.187378E+09 | 0.159958E+09 | 0.137691E+09 | 814454.99 | 0.136876E+09 | 0.00 | 0.00 |
| May | 0.351259E+09 | 28808499.23 | 0.161025E+09 | 6063506.41 | 0.154962E+09 | 0.00 | 0.00 |
| June | 0.401013E+09 | 21621013.38 | 0.176659E+09 | 12028244.03 | 0.164631E+09 | 0.00 | 0.00 |
| July | 0.406677E+09 | 12095008.06 | 0.177281E+09 | 6616296.66 | 0.170665E+09 | 0.00 | 0.00 |
| August | 0.364750E+09 | 21704040.21 | 0.159426E+09 | 1641530.34 | 0.157785E+09 | 0.00 | 0.00 |
| September | 0.277656E+09 | 38287667.56 | 0.132846E+09 | 25838.56 | 0.132820E+09 | 0.00 | 0.00 |
| October | 0.226690E+09 | 92181732.14 | 0.119234E+09 | 0.00 | 0.119234E+09 | 0.00 | 0.00 |
| November | 87740638.12 | 0.242508E+09 | 87597669.79 | 0.00 | 87597669.79 | 0.00 | 0.00 |
| December | 59804461.88 | 0.346318E+09 | 81667786.01 | 0.00 | 81667786.01 | 0.00 | 0.00 |
| Annual Sum or Average | 0.260019E+10 | 0.196428E+10 | 0.153515E+10 | 27195493.98 | 0.150796E+10 | 0.00 | 0.00 |
| Minimum of Months | 52820459.77 | 12095008.06 | 81667786.01 | 0.00 | 81667786.01 | 0.00 | 0.00 |
| Maximum of Months | 0.406677E+09 | 0.406458E+09 | 0.177281E+09 | 12028244.03 | 0.170665E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 52754870.69 | 0.406526E+09 | 87851305.19 | 0.00 | 87851305.19 | 0.00 | 0.00 |
| February | 68345712.65 | 0.308402E+09 | 93613281.56 | 0.00 | 93613281.56 | 0.00 | 0.00 |
| March | 0.115866E+09 | 0.285940E+09 | 0.120260E+09 | 5622.98 | 0.120255E+09 | 0.00 | 0.00 |
| April | 0.187255E+09 | 0.159973E+09 | 0.137691E+09 | 814454.99 | 0.136876E+09 | 0.00 | 0.00 |
| May | 0.351214E+09 | 28806464.78 | 0.161025E+09 | 6063506.41 | 0.154962E+09 | 0.00 | 0.00 |
| June | 0.400979E+09 | 21614137.51 | 0.176659E+09 | 12028244.03 | 0.164631E+09 | 0.00 | 0.00 |
| July | 0.406639E+09 | 12094032.55 | 0.177281E+09 | 6616296.66 | 0.170665E+09 | 0.00 | 0.00 |
| August | 0.364730E+09 | 21691898.38 | 0.159426E+09 | 1641530.34 | 0.157785E+09 | 0.00 | 0.00 |
| September | 0.277640E+09 | 38271423.41 | 0.132846E+09 | 25838.56 | 0.132820E+09 | 0.00 | 0.00 |
| October | 0.226663E+09 | 92131541.14 | 0.119234E+09 | 0.00 | 0.119234E+09 | 0.00 | 0.00 |
| November | 87669234.40 | 0.242485E+09 | 87597669.79 | 0.00 | 87597669.79 | 0.00 | 0.00 |
| December | 59807491.99 | 0.346138E+09 | 81667786.01 | 0.00 | 81667786.01 | 0.00 | 0.00 |
| Annual Sum or Average | 0.259956E+10 | 0.196407E+10 | 0.153515E+10 | 27195493.98 | 0.150796E+10 | 0.00 | 0.00 |
| Minimum of Months | 52754870.69 | 12094032.55 | 81667786.01 | 0.00 | 81667786.01 | 0.00 | 0.00 |
| Maximum of Months | 0.406639E+09 | 0.406526E+09 | 0.177281E+09 | 12028244.03 | 0.170665E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.718757E+09 | 0.360042E+09 | 0.502791E+09 | 0.357141E+09 | 0.145651E+09 | 0.00 | 0.00 |
| February | 0.610347E+09 | 0.279672E+09 | 0.418930E+09 | 0.272196E+09 | 0.146733E+09 | 0.00 | 0.00 |
| March | 0.432150E+09 | 0.274535E+09 | 0.290211E+09 | 0.128898E+09 | 0.161313E+09 | 0.00 | 0.00 |
| April | 0.359592E+09 | 0.163060E+09 | 0.215630E+09 | 54115104.10 | 0.161515E+09 | 0.00 | 0.00 |
| May | 0.368106E+09 | 30128460.96 | 0.167073E+09 | 7576796.02 | 0.159496E+09 | 0.00 | 0.00 |
| June | 0.363993E+09 | 22879410.89 | 0.159351E+09 | 1647151.60 | 0.157704E+09 | 0.00 | 0.00 |
| July | 0.398713E+09 | 11858853.35 | 0.172296E+09 | 3238841.76 | 0.169057E+09 | 0.00 | 0.00 |
| August | 0.456350E+09 | 23056483.48 | 0.200876E+09 | 22577599.97 | 0.178298E+09 | 0.00 | 0.00 |
| September | 0.491486E+09 | 39625493.59 | 0.238407E+09 | 65161043.25 | 0.173246E+09 | 0.00 | 0.00 |
| October | 0.693430E+09 | 91850708.94 | 0.370348E+09 | 0.189674E+09 | 0.180674E+09 | 0.00 | 0.00 |
| November | 0.732363E+09 | 0.222098E+09 | 0.466286E+09 | 0.321602E+09 | 0.144684E+09 | 0.00 | 0.00 |
| December | 0.741555E+09 | 0.315639E+09 | 0.495387E+09 | 0.355537E+09 | 0.139850E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.636684E+10 | 0.183445E+10 | 0.369759E+10 | 0.177937E+10 | 0.191822E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.359592E+09 | 11858853.35 | 0.159351E+09 | 1647151.60 | 0.139850E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.741555E+09 | 0.360042E+09 | 0.502791E+09 | 0.357141E+09 | 0.180674E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.718689E+09 | 0.360019E+09 | 0.502791E+09 | 0.357141E+09 | 0.145651E+09 | 0.00 | 0.00 |
| February | 0.610295E+09 | 0.279624E+09 | 0.418930E+09 | 0.272196E+09 | 0.146733E+09 | 0.00 | 0.00 |
| March | 0.432028E+09 | 0.274549E+09 | 0.290211E+09 | 0.128898E+09 | 0.161313E+09 | 0.00 | 0.00 |
| April | 0.359475E+09 | 0.163055E+09 | 0.215630E+09 | 54115104.10 | 0.161515E+09 | 0.00 | 0.00 |
| May | 0.368060E+09 | 30126402.77 | 0.167073E+09 | 7576796.02 | 0.159496E+09 | 0.00 | 0.00 |
| June | 0.363959E+09 | 22871996.59 | 0.159351E+09 | 1647151.60 | 0.157704E+09 | 0.00 | 0.00 |
| July | 0.398674E+09 | 11857513.81 | 0.172296E+09 | 3238841.76 | 0.169057E+09 | 0.00 | 0.00 |
| August | 0.456331E+09 | 23044001.44 | 0.200876E+09 | 22577599.97 | 0.178298E+09 | 0.00 | 0.00 |
| September | 0.491474E+09 | 39608719.16 | 0.238407E+09 | 65161043.25 | 0.173246E+09 | 0.00 | 0.00 |
| October | 0.693406E+09 | 91821582.51 | 0.370348E+09 | 0.189674E+09 | 0.180674E+09 | 0.00 | 0.00 |
| November | 0.732299E+09 | 0.222089E+09 | 0.466286E+09 | 0.321602E+09 | 0.144684E+09 | 0.00 | 0.00 |
| December | 0.741544E+09 | 0.315556E+09 | 0.495387E+09 | 0.355537E+09 | 0.139850E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.636623E+10 | 0.183422E+10 | 0.369759E+10 | 0.177937E+10 | 0.191822E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.359475E+09 | 11857513.81 | 0.159351E+09 | 1647151.60 | 0.139850E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.741544E+09 | 0.360019E+09 | 0.502791E+09 | 0.357141E+09 | 0.180674E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.906780E+09 | 0.536541E+09 | 0.660812E+09 | 0.442488E+09 | 0.218323E+09 | 0.00 | 0.00 |
| February | 0.809567E+09 | 0.424298E+09 | 0.580447E+09 | 0.353833E+09 | 0.226614E+09 | 0.00 | 0.00 |
| March | 0.666364E+09 | 0.408137E+09 | 0.466782E+09 | 0.207026E+09 | 0.259756E+09 | 0.00 | 0.00 |
| April | 0.677830E+09 | 0.256212E+09 | 0.427561E+09 | 0.151447E+09 | 0.276114E+09 | 0.00 | 0.00 |
| May | 0.712835E+09 | 51906450.09 | 0.349506E+09 | 66949106.90 | 0.282557E+09 | 0.00 | 0.00 |
| June | 0.742856E+09 | 39715658.72 | 0.355648E+09 | 70640573.72 | 0.285008E+09 | 0.00 | 0.00 |
| July | 0.759325E+09 | 21143922.71 | 0.357116E+09 | 54449156.63 | 0.302666E+09 | 0.00 | 0.00 |
| August | 0.817750E+09 | 40050399.17 | 0.387742E+09 | 79557474.92 | 0.308184E+09 | 0.00 | 0.00 |
| September | 0.794808E+09 | 67593387.39 | 0.405127E+09 | 0.122402E+09 | 0.282725E+09 | 0.00 | 0.00 |
| October | 0.995634E+09 | 0.149051E+09 | 0.546269E+09 | 0.265519E+09 | 0.280750E+09 | 0.00 | 0.00 |
| November | 0.926195E+09 | 0.348465E+09 | 0.612449E+09 | 0.395029E+09 | 0.217420E+09 | 0.00 | 0.00 |
| December | 0.924724E+09 | 0.470635E+09 | 0.640704E+09 | 0.432805E+09 | 0.207899E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.973467E+10 | 0.281375E+10 | 0.579016E+10 | 0.264215E+10 | 0.314802E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.666364E+09 | 21143922.71 | 0.349506E+09 | 54449156.63 | 0.207899E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.995634E+09 | 0.536541E+09 | 0.660812E+09 | 0.442488E+09 | 0.308184E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.253860E+09 | 0.544220E+09 | 0.245872E+09 | 85347902.52 | 0.160524E+09 | 0.00 | 0.00 |
| February | 0.278745E+09 | 0.430679E+09 | 0.255130E+09 | 81636932.67 | 0.173493E+09 | 0.00 | 0.00 |
| March | 0.358772E+09 | 0.410727E+09 | 0.296831E+09 | 78133351.41 | 0.218698E+09 | 0.00 | 0.00 |
| April | 0.509644E+09 | 0.254988E+09 | 0.349621E+09 | 98146306.07 | 0.251475E+09 | 0.00 | 0.00 |
| May | 0.695943E+09 | 50270458.56 | 0.343458E+09 | 65435817.29 | 0.278022E+09 | 0.00 | 0.00 |
| June | 0.778884E+09 | 38197620.63 | 0.372956E+09 | 81021666.15 | 0.291935E+09 | 0.00 | 0.00 |
| July | 0.767239E+09 | 21442181.59 | 0.362101E+09 | 57826611.54 | 0.304275E+09 | 0.00 | 0.00 |
| August | 0.727973E+09 | 38664455.30 | 0.346292E+09 | 58621405.29 | 0.287670E+09 | 0.00 | 0.00 |
| September | 0.584649E+09 | 66075654.67 | 0.299566E+09 | 57267252.25 | 0.242299E+09 | 0.00 | 0.00 |
| October | 0.537738E+09 | 0.146708E+09 | 0.295155E+09 | 75844789.61 | 0.219310E+09 | 0.00 | 0.00 |
| November | 0.300295E+09 | 0.354355E+09 | 0.233760E+09 | 73426852.63 | 0.160334E+09 | 0.00 | 0.00 |
| December | 0.257269E+09 | 0.467658E+09 | 0.226985E+09 | 77267943.06 | 0.149717E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.605101E+10 | 0.282399E+10 | 0.362773E+10 | 0.889977E+09 | 0.273775E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.253860E+09 | 21442181.59 | 0.226985E+09 | 57267252.25 | 0.149717E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.778884E+09 | 0.544220E+09 | 0.372956E+09 | 98146306.07 | 0.304275E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.883158E+09 | 0.530463E+09 | 0.652182E+09 | 0.433521E+09 | 0.218661E+09 | 0.00 | 0.00 |
| February | 0.782809E+09 | 0.417381E+09 | 0.568225E+09 | 0.343994E+09 | 0.224230E+09 | 0.00 | 0.00 |
| March | 0.681443E+09 | 0.397879E+09 | 0.485130E+09 | 0.222765E+09 | 0.262366E+09 | 0.00 | 0.00 |
| April | 0.658521E+09 | 0.248543E+09 | 0.423125E+09 | 0.148110E+09 | 0.275015E+09 | 0.00 | 0.00 |
| May | 0.772579E+09 | 48807885.21 | 0.387632E+09 | 0.103282E+09 | 0.284350E+09 | 0.00 | 0.00 |
| June | 0.775109E+09 | 37302597.17 | 0.375710E+09 | 87483016.42 | 0.288227E+09 | 0.00 | 0.00 |
| July | 0.812802E+09 | 20253745.67 | 0.388006E+09 | 82288759.55 | 0.305717E+09 | 0.00 | 0.00 |
| August | 0.833827E+09 | 37866582.20 | 0.399556E+09 | 90829998.97 | 0.308726E+09 | 0.00 | 0.00 |
| September | 0.796960E+09 | 65226590.36 | 0.408467E+09 | 0.123518E+09 | 0.284949E+09 | 0.00 | 0.00 |
| October | 0.984298E+09 | 0.144408E+09 | 0.544624E+09 | 0.263420E+09 | 0.281204E+09 | 0.00 | 0.00 |
| November | 0.921271E+09 | 0.343909E+09 | 0.615270E+09 | 0.397572E+09 | 0.217698E+09 | 0.00 | 0.00 |
| December | 0.878945E+09 | 0.467606E+09 | 0.616689E+09 | 0.410556E+09 | 0.206133E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.978172E+10 | 0.275965E+10 | 0.586462E+10 | 0.270734E+10 | 0.315728E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.658521E+09 | 20253745.67 | 0.375710E+09 | 82288759.55 | 0.206133E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.984298E+09 | 0.530463E+09 | 0.652182E+09 | 0.433521E+09 | 0.308726E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.220490E+09 | 0.523413E+09 | 0.237242E+09 | 76380900.21 | 0.160861E+09 | 0.00 | 0.00 |
| February | 0.242738E+09 | 0.413027E+09 | 0.242908E+09 | 71797887.95 | 0.171110E+09 | 0.00 | 0.00 |
| March | 0.368882E+09 | 0.393444E+09 | 0.315179E+09 | 93871658.47 | 0.221307E+09 | 0.00 | 0.00 |
| April | 0.491047E+09 | 0.247234E+09 | 0.345185E+09 | 94809146.46 | 0.250376E+09 | 0.00 | 0.00 |
| May | 0.757203E+09 | 48573491.76 | 0.381584E+09 | 0.101769E+09 | 0.279815E+09 | 0.00 | 0.00 |
| June | 0.812121E+09 | 36696027.39 | 0.393019E+09 | 97864108.85 | 0.295155E+09 | 0.00 | 0.00 |
| July | 0.820805E+09 | 20575489.60 | 0.392991E+09 | 85666214.46 | 0.307325E+09 | 0.00 | 0.00 |
| August | 0.744384E+09 | 36781409.94 | 0.358106E+09 | 69893929.35 | 0.288213E+09 | 0.00 | 0.00 |
| September | 0.586682E+09 | 63581394.81 | 0.302906E+09 | 58382762.56 | 0.244523E+09 | 0.00 | 0.00 |
| October | 0.524997E+09 | 0.139419E+09 | 0.293509E+09 | 73745867.93 | 0.219764E+09 | 0.00 | 0.00 |
| November | 0.282807E+09 | 0.336296E+09 | 0.236582E+09 | 75969936.22 | 0.160612E+09 | 0.00 | 0.00 |
| December | 0.206481E+09 | 0.456835E+09 | 0.202969E+09 | 55018271.94 | 0.147951E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.605864E+10 | 0.271588E+10 | 0.370218E+10 | 0.955170E+09 | 0.274701E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.206481E+09 | 20575489.60 | 0.202969E+09 | 55018271.94 | 0.147951E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.820805E+09 | 0.523413E+09 | 0.393019E+09 | 0.101769E+09 | 0.307325E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 61533120.97 | 0.350990E+09 | 87851305.19 | 0.00 | 87851305.19 | 0.00 | 0.00 |
| February | 73240952.21 | 0.276462E+09 | 93613281.56 | 0.00 | 93613281.56 | 0.00 | 0.00 |
| March | 0.120481E+09 | 0.259784E+09 | 0.120260E+09 | 5622.98 | 0.120255E+09 | 0.00 | 0.00 |
| April | 0.183433E+09 | 0.157203E+09 | 0.137691E+09 | 814454.99 | 0.136876E+09 | 0.00 | 0.00 |
| May | 0.342400E+09 | 29080738.05 | 0.161025E+09 | 6063506.41 | 0.154962E+09 | 0.00 | 0.00 |
| June | 0.391131E+09 | 21796951.28 | 0.176659E+09 | 12028244.03 | 0.164631E+09 | 0.00 | 0.00 |
| July | 0.396076E+09 | 12352318.96 | 0.177281E+09 | 6616296.66 | 0.170665E+09 | 0.00 | 0.00 |
| August | 0.355394E+09 | 22113970.66 | 0.159426E+09 | 1641530.34 | 0.157785E+09 | 0.00 | 0.00 |
| September | 0.270486E+09 | 39083342.73 | 0.132846E+09 | 25838.56 | 0.132820E+09 | 0.00 | 0.00 |
| October | 0.222009E+09 | 89435606.62 | 0.119234E+09 | 0.00 | 0.119234E+09 | 0.00 | 0.00 |
| November | 90430753.61 | 0.225531E+09 | 87597669.79 | 0.00 | 87597669.79 | 0.00 | 0.00 |
| December | 65977039.45 | 0.301277E+09 | 81667786.01 | 0.00 | 81667786.01 | 0.00 | 0.00 |
| Annual Sum or Average | 0.257259E+10 | 0.178511E+10 | 0.153515E+10 | 27195493.98 | 0.150796E+10 | 0.00 | 0.00 |
| Minimum of Months | 61533120.97 | 12352318.96 | 81667786.01 | 0.00 | 81667786.01 | 0.00 | 0.00 |
| Maximum of Months | 0.396076E+09 | 0.350990E+09 | 0.177281E+09 | 12028244.03 | 0.170665E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 61322301.64 | 0.350657E+09 | 87851305.19 | 0.00 | 87851305.19 | 0.00 | 0.00 |
| February | 73003574.28 | 0.276209E+09 | 93613281.56 | 0.00 | 93613281.56 | 0.00 | 0.00 |
| March | 0.120106E+09 | 0.259621E+09 | 0.120260E+09 | 5622.98 | 0.120255E+09 | 0.00 | 0.00 |
| April | 0.183105E+09 | 0.157087E+09 | 0.137691E+09 | 814454.99 | 0.136876E+09 | 0.00 | 0.00 |
| May | 0.342318E+09 | 29053699.71 | 0.161025E+09 | 6063506.41 | 0.154962E+09 | 0.00 | 0.00 |
| June | 0.391070E+09 | 21770023.90 | 0.176659E+09 | 12028244.03 | 0.164631E+09 | 0.00 | 0.00 |
| July | 0.396017E+09 | 12338329.98 | 0.177281E+09 | 6616296.66 | 0.170665E+09 | 0.00 | 0.00 |
| August | 0.355357E+09 | 22079773.79 | 0.159426E+09 | 1641530.34 | 0.157785E+09 | 0.00 | 0.00 |
| September | 0.270444E+09 | 39037327.34 | 0.132846E+09 | 25838.56 | 0.132820E+09 | 0.00 | 0.00 |
| October | 0.221918E+09 | 89278849.17 | 0.119234E+09 | 0.00 | 0.119234E+09 | 0.00 | 0.00 |
| November | 90154706.12 | 0.225380E+09 | 87597669.79 | 0.00 | 87597669.79 | 0.00 | 0.00 |
| December | 65849835.94 | 0.300870E+09 | 81667786.01 | 0.00 | 81667786.01 | 0.00 | 0.00 |
| Annual Sum or Average | 0.257066E+10 | 0.178338E+10 | 0.153515E+10 | 27195493.98 | 0.150796E+10 | 0.00 | 0.00 |
| Minimum of Months | 61322301.64 | 12338329.98 | 81667786.01 | 0.00 | 81667786.01 | 0.00 | 0.00 |
| Maximum of Months | 0.396017E+09 | 0.350657E+09 | 0.177281E+09 | 12028244.03 | 0.170665E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.725428E+09 | 0.330887E+09 | 0.502791E+09 | 0.357141E+09 | 0.145651E+09 | 0.00 | 0.00 |
| February | 0.612630E+09 | 0.260853E+09 | 0.418930E+09 | 0.272196E+09 | 0.146733E+09 | 0.00 | 0.00 |
| March | 0.433451E+09 | 0.253824E+09 | 0.290211E+09 | 0.128898E+09 | 0.161313E+09 | 0.00 | 0.00 |
| April | 0.354075E+09 | 0.159337E+09 | 0.215630E+09 | 54115104.10 | 0.161515E+09 | 0.00 | 0.00 |
| May | 0.359027E+09 | 30287669.90 | 0.167073E+09 | 7576796.02 | 0.159496E+09 | 0.00 | 0.00 |
| June | 0.354347E+09 | 23120070.70 | 0.159351E+09 | 1647151.60 | 0.157704E+09 | 0.00 | 0.00 |
| July | 0.388144E+09 | 12151251.97 | 0.172296E+09 | 3238841.76 | 0.169057E+09 | 0.00 | 0.00 |
| August | 0.446230E+09 | 23414291.46 | 0.200876E+09 | 22577599.97 | 0.178298E+09 | 0.00 | 0.00 |
| September | 0.482885E+09 | 40129863.73 | 0.238407E+09 | 65161043.25 | 0.173246E+09 | 0.00 | 0.00 |
| October | 0.685037E+09 | 89714027.25 | 0.370348E+09 | 0.189674E+09 | 0.180674E+09 | 0.00 | 0.00 |
| November | 0.728939E+09 | 0.213055E+09 | 0.466286E+09 | 0.321602E+09 | 0.144684E+09 | 0.00 | 0.00 |
| December | 0.744011E+09 | 0.291352E+09 | 0.495387E+09 | 0.355537E+09 | 0.139850E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.631420E+10 | 0.172813E+10 | 0.369759E+10 | 0.177937E+10 | 0.191822E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.354075E+09 | 12151251.97 | 0.159351E+09 | 1647151.60 | 0.139850E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.744011E+09 | 0.330887E+09 | 0.502791E+09 | 0.357141E+09 | 0.180674E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.725128E+09 | 0.330757E+09 | 0.502791E+09 | 0.357141E+09 | 0.145651E+09 | 0.00 | 0.00 |
| February | 0.612399E+09 | 0.260658E+09 | 0.418930E+09 | 0.272196E+09 | 0.146733E+09 | 0.00 | 0.00 |
| March | 0.433040E+09 | 0.253807E+09 | 0.290211E+09 | 0.128898E+09 | 0.161313E+09 | 0.00 | 0.00 |
| April | 0.353788E+09 | 0.159225E+09 | 0.215630E+09 | 54115104.10 | 0.161515E+09 | 0.00 | 0.00 |
| May | 0.358941E+09 | 30260129.96 | 0.167073E+09 | 7576796.02 | 0.159496E+09 | 0.00 | 0.00 |
| June | 0.354281E+09 | 23091061.97 | 0.159351E+09 | 1647151.60 | 0.157704E+09 | 0.00 | 0.00 |
| July | 0.388081E+09 | 12135594.79 | 0.172296E+09 | 3238841.76 | 0.169057E+09 | 0.00 | 0.00 |
| August | 0.446193E+09 | 23374148.41 | 0.200876E+09 | 22577599.97 | 0.178298E+09 | 0.00 | 0.00 |
| September | 0.482846E+09 | 40083959.85 | 0.238407E+09 | 65161043.25 | 0.173246E+09 | 0.00 | 0.00 |
| October | 0.684951E+09 | 89632368.02 | 0.370348E+09 | 0.189674E+09 | 0.180674E+09 | 0.00 | 0.00 |
| November | 0.728748E+09 | 0.212956E+09 | 0.466286E+09 | 0.321602E+09 | 0.144684E+09 | 0.00 | 0.00 |
| December | 0.743889E+09 | 0.291146E+09 | 0.495387E+09 | 0.355537E+09 | 0.139850E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.631229E+10 | 0.172713E+10 | 0.369759E+10 | 0.177937E+10 | 0.191822E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.353788E+09 | 12135594.79 | 0.159351E+09 | 1647151.60 | 0.139850E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.743889E+09 | 0.330757E+09 | 0.502791E+09 | 0.357141E+09 | 0.180674E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 41322928.52 | 57479981.03 | 35846939.95 | 18327907.91 | 17519032.04 | 0.00 | 0.00 |
| February | 43096302.45 | 45199336.13 | 35823924.91 | 17228195.46 | 18595729.45 | 0.00 | 0.00 |
| March | 61431521.78 | 42982927.37 | 46771595.74 | 22523537.29 | 24248058.45 | 0.00 | 0.00 |
| April | 73648545.70 | 28044770.86 | 49789167.74 | 22554408.81 | 27234758.93 | 0.00 | 0.00 |
| May | 95651794.60 | 8222994.51 | 52923985.63 | 22964933.24 | 29959052.39 | 0.00 | 0.00 |
| June | 97415560.61 | 6858281.32 | 51916412.70 | 20596665.15 | 31319747.55 | 0.00 | 0.00 |
| July | 97416140.52 | 4717146.20 | 51760477.65 | 18968349.54 | 32792128.11 | 0.00 | 0.00 |
| August | 89015322.70 | 6792066.51 | 47674155.21 | 16377440.95 | 31296714.25 | 0.00 | 0.00 |
| September | 72375514.36 | 9935077.14 | 40806582.60 | 14002981.45 | 26803601.15 | 0.00 | 0.00 |
| October | 69887114.93 | 18123057.84 | 41818126.21 | 17695621.18 | 24122505.02 | 0.00 | 0.00 |
| November | 47403822.54 | 38237868.73 | 35749394.81 | 18229295.42 | 17520099.39 | 0.00 | 0.00 |
| December | 34213310.32 | 51249955.20 | 29106776.81 | 13201858.30 | 15904918.51 | 0.00 | 0.00 |
| Annual Sum or Average | 0.822878E+09 | 0.317843E+09 | 0.519988E+09 | 0.222671E+09 | 0.297316E+09 | 0.00 | 0.00 |
| Minimum of Months | 34213310.32 | 4717146.20 | 29106776.81 | 13201858.30 | 15904918.51 | 0.00 | 0.00 |
| Maximum of Months | 97416140.52 | 57479981.03 | 52923985.63 | 22964933.24 | 32792128.11 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.120304E+09 | 0.179306E+09 | 0.106761E+09 | 54585070.89 | 52176037.26 | 0.00 | 0.00 |
| February | 0.128260E+09 | 0.136362E+09 | 0.106693E+09 | 51309853.55 | 55382710.10 | 0.00 | 0.00 |
| March | 0.183758E+09 | 0.129388E+09 | 0.139297E+09 | 67080699.33 | 72216752.51 | 0.00 | 0.00 |
| April | 0.220411E+09 | 83748222.37 | 0.148285E+09 | 67172642.41 | 81111889.83 | 0.00 | 0.00 |
| May | 0.278690E+09 | 31189470.52 | 0.157621E+09 | 68395286.33 | 89225513.73 | 0.00 | 0.00 |
| June | 0.282163E+09 | 27487123.04 | 0.154620E+09 | 61341994.57 | 93278002.55 | 0.00 | 0.00 |
| July | 0.280140E+09 | 21932777.57 | 0.154156E+09 | 56492465.45 | 97663118.26 | 0.00 | 0.00 |
| August | 0.254828E+09 | 29322503.04 | 0.141985E+09 | 48776094.91 | 93209403.65 | 0.00 | 0.00 |
| September | 0.207456E+09 | 39139624.00 | 0.121532E+09 | 41704363.58 | 79827794.65 | 0.00 | 0.00 |
| October | 0.201823E+09 | 64145452.48 | 0.124545E+09 | 52701963.68 | 71842823.17 | 0.00 | 0.00 |
| November | 0.137548E+09 | 0.121377E+09 | 0.106471E+09 | 54291378.37 | 52179216.10 | 0.00 | 0.00 |
| December | 98142699.22 | 0.163629E+09 | 86687224.96 | 39318419.47 | 47368805.49 | 0.00 | 0.00 |
| Annual Sum or Average | 0.239352E+10 | 0.102703E+10 | 0.154865E+10 | 0.663170E+09 | 0.885482E+09 | 0.00 | 0.00 |
| Minimum of Months | 98142699.22 | 21932777.57 | 86687224.96 | 39318419.47 | 47368805.49 | 0.00 | 0.00 |
| Maximum of Months | 0.282163E+09 | 0.179306E+09 | 0.157621E+09 | 68395286.33 | 97663118.26 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 38223360.83 | 64905593.92 | 35846939.95 | 18327907.91 | 17519032.04 | 0.00 | 0.00 |
| February | 40816383.79 | 49882034.62 | 35823924.91 | 17228195.46 | 18595729.45 | 0.00 | 0.00 |
| March | 59338745.19 | 47230274.81 | 46771595.74 | 22523537.29 | 24248058.45 | 0.00 | 0.00 |
| April | 73299666.53 | 28846070.61 | 49789167.74 | 22554408.81 | 27234758.93 | 0.00 | 0.00 |
| May | 97132083.73 | 8008667.75 | 52923985.63 | 22964933.24 | 29959052.39 | 0.00 | 0.00 |
| June | 99014940.17 | 6599818.32 | 51916412.70 | 20596665.15 | 31319747.55 | 0.00 | 0.00 |
| July | 99233576.43 | 4437326.16 | 51760477.65 | 18968349.54 | 32792128.11 | 0.00 | 0.00 |
| August | 90651563.92 | 6528329.09 | 47674155.21 | 16377440.95 | 31296714.25 | 0.00 | 0.00 |
| September | 73529505.04 | 9782585.67 | 40806582.60 | 14002981.45 | 26803601.15 | 0.00 | 0.00 |
| October | 70450808.29 | 18560321.80 | 41818126.21 | 17695621.18 | 24122505.02 | 0.00 | 0.00 |
| November | 45861402.93 | 40896043.87 | 35749394.81 | 18229295.42 | 17520099.39 | 0.00 | 0.00 |
| December | 31958207.93 | 57728575.71 | 29106776.81 | 13201858.30 | 15904918.51 | 0.00 | 0.00 |
| Annual Sum or Average | 0.819510E+09 | 0.343406E+09 | 0.519988E+09 | 0.222671E+09 | 0.297316E+09 | 0.00 | 0.00 |
| Minimum of Months | 31958207.93 | 4437326.16 | 29106776.81 | 13201858.30 | 15904918.51 | 0.00 | 0.00 |
| Maximum of Months | 99233576.43 | 64905593.92 | 52923985.63 | 22964933.24 | 32792128.11 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
| January | 13.57 | 11.02 | 8.64 | 3.24 | 3.13 | 48.31 | 209.17 | 0.01 |
| February | 15.49 | 12.82 | 10.40 | 2.82 | 4.36 | 58.07 | 218.23 | 0.02 |
| March | 17.07 | 13.58 | 10.72 | 3.68 | 7.24 | 76.61 | 186.08 | 0.03 |
| April | 21.23 | 17.54 | 15.23 | 2.65 | 11.47 | 90.28 | 216.86 | 0.02 |
| May | 26.90 | 22.82 | 21.10 | 3.11 | 19.64 | 106.10 | 173.47 | 0.04 |
| June | 27.61 | 23.37 | 21.62 | 2.44 | 19.77 | 115.40 | 187.69 | 0.03 |
| July | 27.94 | 24.58 | 23.34 | 2.53 | 20.70 | 123.49 | 154.05 | 0.05 |
| August | 27.43 | 23.90 | 22.52 | 3.20 | 20.40 | 118.51 | 145.78 | 0.03 |
| September | 26.23 | 23.37 | 22.24 | 3.39 | 19.02 | 101.73 | 135.58 | 0.05 |
| October | 24.23 | 20.47 | 18.40 | 4.11 | 16.60 | 78.24 | 178.15 | 0.01 |
| November | 18.91 | 15.31 | 12.62 | 2.63 | 7.99 | 49.56 | 205.43 | 0.01 |
| December | 15.68 | 12.88 | 10.53 | 3.17 | 6.01 | 45.08 | 191.18 | 0.02 |
| Annual Sum or Average | 21.89 | 18.50 | 16.48 | 3.09 | 13.08 | 84.44 | 183.16 | 0.03 |
| Minimum of Months | 13.57 | 11.02 | 8.64 | 2.44 | 3.13 | 45.08 | 135.58 | 0.01 |
| Maximum of Months | 27.94 | 24.58 | 23.34 | 4.11 | 20.70 | 123.49 | 218.23 | 0.05 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 27.00 | 02-JAN-14:00 | 18.67 | 14.00 | 1.50 | 17.75 | 146.50 | 0.00 |
| February | 28.30 | 02-FEB-12:00 | 20.78 | 17.20 | 6.60 | 17.93 | 127.50 | 748.50 |
| March | 30.00 | 26-MAR-13:00 | 19.88 | 14.40 | 3.00 | 19.52 | 288.50 | 548.00 |
| April | 33.30 | 28-APR-14:00 | 23.06 | 18.80 | 4.10 | 23.15 | 150.50 | 762.50 |
| May | 33.90 | 07-MAY-13:00 | 23.76 | 19.40 | 4.10 | 23.15 | 287.50 | 507.50 |
| June | 35.00 | 14-JUN-13:00 | 23.95 | 19.40 | 2.10 | 24.16 | 194.50 | 712.50 |
| July | 36.10 | 21-JUL-15:00 | 25.96 | 22.20 | 1.50 | 26.65 | 216.00 | 245.00 |
| August | 36.30 | 30-AUG-15:00 | 23.74 | 18.50 | 2.40 | 25.33 | 116.00 | 698.50 |
| September | 36.40 | 09-SEP-16:00 | 26.65 | 23.40 | 4.40 | 26.48 | 114.00 | 401.50 |
| October | 34.00 | 05-OCT-14:00 | 24.05 | 20.00 | 2.60 | 29.55 | 169.50 | 606.00 |
| November | 30.00 | 01-NOV-13:00 | 25.01 | 23.30 | 2.00 | 26.48 | 216.50 | 118.00 |
| December | 30.00 | 13-DEC-14:00 | 21.84 | 18.00 | 3.10 | 20.92 | 101.50 | 682.50 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 27.00 | 18.67 | 14.00 | 1.50 | 17.75 | 101.50 | 0.00 | |
| Maximum of Months | 36.40 | 26.65 | 23.40 | 6.60 | 29.55 | 288.50 | 762.50 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 0.00 | 05-JAN-05:00 | -0.0 | -0.0 | 2.10 | -16.0 | 0.00 | 0.00 |
| February | -3.4 | 05-FEB-07:10 | -5.4 | -9.4 | 4.68 | -21.3 | 0.00 | 0.00 |
| March | 1.10 | 09-MAR-05:00 | -2.1 | -7.3 | 3.60 | -14.4 | 0.00 | 0.00 |
| April | 8.30 | 11-APR-05:00 | 6.95 | 5.50 | 0.00 | -6.9 | 0.00 | 0.00 |
| May | 21.10 | 07-MAY-00:00 | 19.58 | 18.90 | 0.00 | 11.46 | 0.00 | 0.00 |
| June | 20.60 | 07-JUN-01:00 | 18.00 | 16.70 | 3.60 | 10.50 | 0.00 | 0.00 |
| July | 22.20 | 11-JUL-19:00 | 21.37 | 21.10 | 2.10 | 20.22 | 0.00 | 0.00 |
| August | 20.20 | 25-AUG-23:00 | 20.20 | 20.20 | 5.30 | 11.84 | 0.00 | 0.00 |
| September | 19.20 | 07-SEP-17:00 | 19.20 | 19.20 | 2.50 | 16.85 | 35.00 | 7.00 |
| October | 10.00 | 28-OCT-04:00 | 5.56 | 0.00 | 3.60 | -0.1 | 0.00 | 0.00 |
| November | 7.20 | 12-NOV-07:49 | 4.12 | 0.18 | 4.60 | -9.0 | 36.00 | 517.00 |
| December | 0.00 | 21-DEC-04:00 | -0.9 | -2.0 | 2.10 | -16.2 | 0.00 | 0.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | -3.4 | -5.4 | -9.4 | 0.00 | -21.3 | 0.00 | 0.00 | |
| Maximum of Months | 22.20 | 21.37 | 21.10 | 5.30 | 20.22 | 36.00 | 517.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 22.11 | 31-JAN-12:00 | 25.00 | 21.00 | 5.70 | 20.92 | 336.50 | 96.00 |
| February | 21.49 | 24-FEB-12:00 | 27.70 | 18.80 | 4.10 | 17.75 | 165.00 | 746.50 |
| March | 22.77 | 30-MAR-12:00 | 29.40 | 20.00 | 2.50 | 27.14 | 340.00 | 0.00 |
| April | 25.55 | 28-APR-15:00 | 32.20 | 23.30 | 3.60 | 22.47 | 156.00 | 575.50 |
| May | 25.84 | 27-MAY-13:00 | 31.70 | 23.90 | 3.10 | 22.13 | 168.50 | 735.50 |
| June | 26.52 | 29-JUN-16:00 | 29.40 | 25.60 | 1.50 | 26.32 | 164.00 | 36.00 |
| July | 27.17 | 22-JUL-10:00 | 32.20 | 25.60 | 2.10 | 21.96 | 191.00 | 719.50 |
| August | 27.24 | 07-AUG-12:00 | 31.00 | 26.00 | 3.10 | 27.95 | 473.00 | 200.00 |
| September | 27.79 | 10-SEP-12:00 | 35.00 | 25.50 | 2.90 | 24.66 | 239.50 | 662.00 |
| October | 28.18 | 07-OCT-07:00 | 29.00 | 28.00 | 2.60 | 21.09 | 95.00 | 500.50 |
| November | 25.01 | 01-NOV-13:00 | 30.00 | 23.30 | 2.00 | 26.48 | 216.50 | 118.00 |
| December | 24.12 | 12-DEC-13:00 | 27.00 | 23.00 | 2.10 | 19.17 | 160.50 | 599.50 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 21.49 | 25.00 | 18.80 | 1.50 | 17.75 | 95.00 | 0.00 | |
| Maximum of Months | 28.18 | 35.00 | 28.00 | 5.70 | 27.95 | 473.00 | 746.50 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 21.00 | 31-JAN-12:00 | 25.00 | 22.11 | 5.70 | 20.92 | 336.50 | 96.00 |
| February | 20.20 | 02-FEB-22:00 | 21.50 | 20.56 | 4.80 | 14.65 | 0.00 | 0.00 |
| March | 21.10 | 07-MAR-08:00 | 23.30 | 21.69 | 2.00 | 13.91 | 126.00 | 566.50 |
| April | 23.30 | 28-APR-15:00 | 32.20 | 25.55 | 3.60 | 22.47 | 156.00 | 575.50 |
| May | 24.40 | 26-MAY-08:20 | 27.07 | 25.09 | 3.10 | 23.71 | 252.67 | 47.33 |
| June | 25.60 | 29-JUN-14:00 | 27.20 | 26.00 | 5.10 | 24.16 | 335.00 | 238.00 |
| July | 25.60 | 02-JUL-05:00 | 26.10 | 25.71 | 2.60 | 19.52 | 30.50 | 8.50 |
| August | 26.60 | 09-AUG-18:00 | 26.60 | 26.60 | 1.90 | 19.52 | 26.00 | 23.00 |
| September | 25.50 | 10-SEP-12:00 | 35.00 | 27.79 | 2.90 | 24.66 | 239.50 | 662.00 |
| October | 28.00 | 07-OCT-07:00 | 29.00 | 28.18 | 2.60 | 21.09 | 95.00 | 500.50 |
| November | 23.80 | 01-NOV-10:00 | 26.10 | 24.39 | 2.00 | 22.64 | 228.50 | 113.00 |
| December | 23.00 | 12-DEC-13:00 | 27.00 | 24.12 | 2.10 | 19.17 | 160.50 | 599.50 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 20.20 | 21.50 | 20.56 | 1.90 | 13.91 | 0.00 | 0.00 | |
| Maximum of Months | 28.00 | 35.00 | 28.18 | 5.70 | 24.66 | 336.50 | 662.00 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
| January | 18.00 | 13.00 | 16.00 | 20.46 | 29.60 | 0.00 |
| February | 18.00 | 13.00 | 16.00 | 20.78 | 36.65 | 0.00 |
| March | 18.00 | 13.00 | 16.00 | 22.23 | 38.94 | 0.00 |
| April | 18.00 | 13.00 | 16.00 | 24.49 | 49.11 | 0.00 |
| May | 18.00 | 13.00 | 16.00 | 26.95 | 46.95 | 0.00 |
| June | 18.00 | 13.00 | 16.00 | 28.93 | 51.71 | 0.00 |
| July | 18.00 | 13.00 | 16.00 | 29.89 | 48.43 | 0.00 |
| August | 18.00 | 13.00 | 16.00 | 29.58 | 45.50 | 0.00 |
| September | 18.00 | 13.00 | 16.00 | 28.08 | 39.22 | 0.00 |
| October | 18.00 | 13.00 | 16.00 | 25.80 | 37.51 | 0.00 |
| November | 18.00 | 13.00 | 16.00 | 23.35 | 31.26 | 0.00 |
| December | 18.00 | 13.00 | 16.00 | 21.40 | 27.18 | 0.00 |
| Annual Sum or Average | 18.00 | 13.00 | 16.00 | 25.18 | 40.17 | 0.00 |
| Minimum of Months | 18.00 | 13.00 | 16.00 | 20.46 | 27.18 | 0.00 |
| Maximum of Months | 18.00 | 13.00 | 16.00 | 29.89 | 51.71 | 0.00 |
Report: WaterHeaterReportMonthly
For: SWHSYS1 WATER HEATER
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.272731E+11 | -0.263149E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -958194433.1 | 59.95 | 0.00 | 0.00 |
| February | 0.244319E+11 | -0.235747E+11 | 0.00 | 0.00 | 672.00 | 0.00 | -857165462.5 | 59.95 | 0.00 | 0.00 |
| March | 0.260744E+11 | -0.251346E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -939732436.0 | 59.95 | 0.00 | 0.00 |
| April | 0.237376E+11 | -0.228621E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -875471411.3 | 59.95 | 0.00 | 0.00 |
| May | 0.228598E+11 | -0.219896E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -870142188.1 | 59.95 | 0.00 | 0.00 |
| June | 0.208394E+11 | -0.200030E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -836346721.8 | 59.95 | 0.00 | 0.00 |
| July | 0.208856E+11 | -0.200249E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -860778419.5 | 59.95 | 0.00 | 0.00 |
| August | 0.210942E+11 | -0.202336E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -860606049.9 | 59.95 | 0.00 | 0.00 |
| September | 0.213869E+11 | -0.205487E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -838211224.9 | 59.95 | 0.00 | 0.00 |
| October | 0.236315E+11 | -0.227561E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -875404073.6 | 59.95 | 0.00 | 0.00 |
| November | 0.244812E+11 | -0.236009E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -880241009.3 | 59.95 | 0.00 | 0.00 |
| December | 0.266264E+11 | -0.256887E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -937704850.6 | 59.95 | 0.00 | 0.00 |
| Annual Sum or Average | 0.283322E+12 | -0.272732E+12 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.105900E+11 | 59.95 | 0.00 | 0.00 |
| Minimum of Months | 0.208394E+11 | -0.263149E+11 | 0.00 | 0.00 | 672.00 | 0.00 | -958194433.1 | 59.95 | 0.00 | 0.00 |
| Maximum of Months | 0.272731E+11 | -0.200030E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -836346721.8 | 59.95 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
| January | 307.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 295.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 296.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 347.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 353.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 394.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 390.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 380.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 342.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 330.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 308.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 282.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 4027.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 282.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 394.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 881568.23 | 4222.79 | 06-FEB-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 752001.99 | 2433.89 | 13-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 1633570.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 881568.23 | 4222.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.129424E+09 | 873.48 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 96226059.09 | 1342.33 | 05-FEB-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 81897006.53 | 697.34 | 12-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 987744.20 | 131.59 | 16-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 96011435.55 | 1000.69 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.404546E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.129424E+09 | 1342.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.343681E+09 | 1143.94 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.196842E+09 | 1494.29 | 05-FEB-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.115993E+09 | 749.52 | 09-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 7852197.79 | 338.48 | 16-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.213875E+09 | 1195.18 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.878243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.343681E+09 | 1494.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.124043E+09 | 892.58 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 91568066.05 | 1359.03 | 05-FEB-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 78181763.63 | 696.32 | 12-MAR-06:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 1147725.40 | 150.86 | 16-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 98203273.14 | 1031.81 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.393143E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.124043E+09 | 1359.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.326974E+09 | 1168.05 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.186929E+09 | 1511.66 | 05-FEB-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.111383E+09 | 766.40 | 09-MAR-06:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 7878980.71 | 352.61 | 16-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.216356E+09 | 1221.03 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.849521E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.326974E+09 | 1511.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.157734E+09 | 767.97 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 97255098.75 | 963.73 | 05-FEB-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 45762865.24 | 420.31 | 12-MAR-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 415622.62 | 65.37 | 16-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 90388074.74 | 808.33 | 21-DEC-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.391555E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.157734E+09 | 963.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.158500E+09 | 769.06 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 97580105.29 | 964.61 | 05-FEB-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 45730220.02 | 419.74 | 12-MAR-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 429257.48 | 66.23 | 16-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 91150424.28 | 810.32 | 21-DEC-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.393390E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.158500E+09 | 964.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 24763258.68 | 471.28 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 31188259.56 | 784.16 | 05-FEB-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 26181922.44 | 382.75 | 12-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 29916598.83 | 577.50 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.112050E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 31188259.56 | 784.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 24815251.83 | 472.35 | 05-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 31320993.41 | 785.09 | 05-FEB-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 26167596.10 | 382.60 | 12-MAR-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 30068101.51 | 580.42 | 21-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.112372E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 31320993.41 | 785.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.104689E+10 | 0.918579E+09 | 6437.75 | 31-JAN-11:02 | 4100.67 | 0.00 |
| February | 0.00 | 0.00 | 0.963918E+09 | 0.801135E+09 | 6392.03 | 02-FEB-22:52 | 4223.14 | 0.00 |
| March | 0.00 | 0.00 | 0.955556E+09 | 0.779608E+09 | 6502.92 | 18-MAR-09:32 | 3618.99 | 0.00 |
| April | 0.00 | 0.00 | 0.159594E+10 | 0.128622E+10 | 6526.69 | 30-APR-11:02 | 3577.35 | 0.00 |
| May | 0.00 | 0.00 | 0.346091E+10 | 0.262613E+10 | 6468.63 | 23-MAY-06:52 | 3769.64 | 0.00 |
| June | 0.00 | 0.00 | 0.369373E+10 | 0.281665E+10 | 6450.51 | 06-JUN-07:42 | 3957.23 | 0.00 |
| July | 0.00 | 0.00 | 0.435770E+10 | 0.323124E+10 | 6384.46 | 31-JUL-12:22 | 4251.33 | 0.00 |
| August | 0.00 | 0.00 | 0.466311E+10 | 0.358760E+10 | 6498.08 | 29-AUG-08:62 | 3822.31 | 0.00 |
| September | 0.00 | 0.00 | 0.432428E+10 | 0.332260E+10 | 6520.29 | 05-SEP-08:42 | 3718.52 | 0.00 |
| October | 0.00 | 0.00 | 0.405907E+10 | 0.328160E+10 | 6480.00 | 22-OCT-09:02 | 3856.63 | 0.00 |
| November | 0.00 | 0.00 | 0.224587E+10 | 0.194532E+10 | 6522.15 | 29-NOV-11:52 | 3767.83 | 0.00 |
| December | 0.00 | 0.00 | 0.163198E+10 | 0.141992E+10 | 6523.86 | 12-DEC-10:22 | 3794.82 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.329989E+11 | 0.260166E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.955556E+09 | 0.779608E+09 | 6384.46 | 3577.35 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.466311E+10 | 0.358760E+10 | 6526.69 | 4251.33 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.329856E+09 | 0.252049E+09 | 6157.53 | 31-JAN-11:22 | 3700.56 | 0.00 |
| February | 0.00 | 0.00 | 0.403456E+09 | 0.304004E+09 | 6147.80 | 02-FEB-22:52 | 3734.08 | 0.00 |
| March | 0.00 | 0.00 | 0.590497E+09 | 0.448764E+09 | 6170.26 | 18-MAR-09:42 | 3397.09 | 0.00 |
| April | 0.00 | 0.00 | 0.134252E+10 | 0.105334E+10 | 6247.00 | 24-APR-10:42 | 3409.94 | 0.00 |
| May | 0.00 | 0.00 | 0.344452E+10 | 0.260857E+10 | 6171.50 | 23-MAY-06:52 | 3614.92 | 0.00 |
| June | 0.00 | 0.00 | 0.377819E+10 | 0.289053E+10 | 6163.63 | 06-JUN-07:42 | 3775.17 | 0.00 |
| July | 0.00 | 0.00 | 0.438682E+10 | 0.325835E+10 | 6105.20 | 31-JUL-12:22 | 4020.58 | 0.00 |
| August | 0.00 | 0.00 | 0.452997E+10 | 0.346024E+10 | 6196.90 | 29-AUG-08:62 | 3670.17 | 0.00 |
| September | 0.00 | 0.00 | 0.398109E+10 | 0.300420E+10 | 6251.57 | 05-SEP-08:42 | 3460.43 | 0.00 |
| October | 0.00 | 0.00 | 0.333301E+10 | 0.260165E+10 | 6231.59 | 20-OCT-08:22 | 3558.22 | 0.00 |
| November | 0.00 | 0.00 | 0.134020E+10 | 0.108500E+10 | 6249.15 | 29-NOV-11:52 | 3517.27 | 0.00 |
| December | 0.00 | 0.00 | 0.790718E+09 | 0.621990E+09 | 6276.32 | 12-DEC-11:12 | 3448.05 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.282508E+11 | 0.215887E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.329856E+09 | 0.252049E+09 | 6105.20 | 3397.09 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.452997E+10 | 0.346024E+10 | 6276.32 | 4020.58 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.920707E+09 | 0.801525E+09 | 7345.99 | 31-JAN-07:01 | 4619.19 | 0.00 |
| February | 0.00 | 0.00 | 0.103064E+10 | 0.860891E+09 | 7358.23 | 03-FEB-07:01 | 4599.77 | 0.00 |
| March | 0.00 | 0.00 | 0.112113E+10 | 0.935672E+09 | 7498.56 | 07-MAR-07:01 | 4384.58 | 0.00 |
| April | 0.00 | 0.00 | 0.149411E+10 | 0.123413E+10 | 7608.20 | 28-APR-06:01 | 4270.42 | 0.00 |
| May | 0.00 | 0.00 | 0.299376E+10 | 0.227208E+10 | 7742.31 | 23-MAY-06:01 | 3778.56 | 0.00 |
| June | 0.00 | 0.00 | 0.323637E+10 | 0.242771E+10 | 7742.13 | 05-JUN-06:01 | 4290.32 | 0.00 |
| July | 0.00 | 0.00 | 0.346289E+10 | 0.250699E+10 | 7741.69 | 12-JUL-06:01 | 3972.86 | 0.00 |
| August | 0.00 | 0.00 | 0.402090E+10 | 0.297397E+10 | 7742.45 | 29-AUG-06:01 | 4116.12 | 0.00 |
| September | 0.00 | 0.00 | 0.347020E+10 | 0.255244E+10 | 7742.45 | 01-SEP-06:02 | 3991.28 | 0.00 |
| October | 0.00 | 0.00 | 0.330050E+10 | 0.263227E+10 | 7742.45 | 23-OCT-06:01 | 4060.57 | 0.00 |
| November | 0.00 | 0.00 | 0.198978E+10 | 0.170050E+10 | 7721.26 | 02-NOV-06:01 | 4100.16 | 0.00 |
| December | 0.00 | 0.00 | 0.128187E+10 | 0.109527E+10 | 7556.68 | 15-DEC-07:01 | 4400.14 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.283228E+11 | 0.219934E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.920707E+09 | 0.801525E+09 | 7345.99 | 3778.56 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.402090E+10 | 0.297397E+10 | 7742.45 | 4619.19 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.309817E+09 | 0.234633E+09 | 5799.10 | 31-JAN-11:22 | 3499.86 | 0.00 |
| February | 0.00 | 0.00 | 0.366750E+09 | 0.272907E+09 | 5789.38 | 02-FEB-22:52 | 3493.92 | 0.00 |
| March | 0.00 | 0.00 | 0.606168E+09 | 0.460848E+09 | 5812.69 | 18-MAR-09:42 | 3211.90 | 0.00 |
| April | 0.00 | 0.00 | 0.133156E+10 | 0.104170E+10 | 5878.01 | 24-APR-10:42 | 3280.84 | 0.00 |
| May | 0.00 | 0.00 | 0.352920E+10 | 0.268245E+10 | 5811.82 | 23-MAY-06:52 | 3408.79 | 0.00 |
| June | 0.00 | 0.00 | 0.383316E+10 | 0.293914E+10 | 5808.95 | 06-JUN-07:42 | 3555.60 | 0.00 |
| July | 0.00 | 0.00 | 0.447640E+10 | 0.334018E+10 | 5745.22 | 12-JUL-21:52 | 3788.82 | 0.00 |
| August | 0.00 | 0.00 | 0.454947E+10 | 0.347732E+10 | 5826.95 | 29-AUG-08:62 | 3483.92 | 0.00 |
| September | 0.00 | 0.00 | 0.398108E+10 | 0.300311E+10 | 5882.82 | 05-SEP-08:42 | 3269.37 | 0.00 |
| October | 0.00 | 0.00 | 0.331314E+10 | 0.258133E+10 | 5873.44 | 20-OCT-08:22 | 3329.20 | 0.00 |
| November | 0.00 | 0.00 | 0.133204E+10 | 0.107758E+10 | 5883.14 | 29-NOV-11:52 | 3313.80 | 0.00 |
| December | 0.00 | 0.00 | 0.743777E+09 | 0.578732E+09 | 5909.82 | 12-DEC-11:12 | 3246.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.283726E+11 | 0.216899E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.309817E+09 | 0.234633E+09 | 5745.22 | 3211.90 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.454947E+10 | 0.347732E+10 | 5909.82 | 3788.82 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.354929E+09 | 0.275754E+09 | 5185.46 | 30-JAN-22:42 | 3085.15 | 0.00 |
| February | 0.00 | 0.00 | 0.423300E+09 | 0.319695E+09 | 5176.95 | 02-FEB-22:52 | 3166.00 | 0.00 |
| March | 0.00 | 0.00 | 0.648416E+09 | 0.499819E+09 | 5191.85 | 18-MAR-09:42 | 2892.63 | 0.00 |
| April | 0.00 | 0.00 | 0.130578E+10 | 0.101889E+10 | 5256.73 | 24-APR-10:42 | 2879.02 | 0.00 |
| May | 0.00 | 0.00 | 0.313096E+10 | 0.233918E+10 | 5180.69 | 23-MAY-06:52 | 3113.81 | 0.00 |
| June | 0.00 | 0.00 | 0.336322E+10 | 0.252271E+10 | 5184.18 | 06-JUN-07:42 | 3171.63 | 0.00 |
| July | 0.00 | 0.00 | 0.387957E+10 | 0.281939E+10 | 5153.81 | 13-JUL-14:32 | 3320.24 | 0.00 |
| August | 0.00 | 0.00 | 0.390210E+10 | 0.291052E+10 | 5214.63 | 29-AUG-08:62 | 3089.00 | 0.00 |
| September | 0.00 | 0.00 | 0.346555E+10 | 0.255870E+10 | 5266.28 | 05-SEP-08:42 | 2897.68 | 0.00 |
| October | 0.00 | 0.00 | 0.289836E+10 | 0.222287E+10 | 5247.81 | 20-OCT-08:22 | 2980.89 | 0.00 |
| November | 0.00 | 0.00 | 0.130356E+10 | 0.105702E+10 | 5252.47 | 29-NOV-11:52 | 2983.54 | 0.00 |
| December | 0.00 | 0.00 | 0.816790E+09 | 0.650955E+09 | 5270.20 | 12-DEC-11:12 | 2944.37 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.254925E+11 | 0.191955E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.354929E+09 | 0.275754E+09 | 5153.81 | 2879.02 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.390210E+10 | 0.291052E+10 | 5270.20 | 3320.24 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.354109E+09 | 0.275080E+09 | 5178.69 | 30-JAN-22:42 | 3081.24 | 0.00 |
| February | 0.00 | 0.00 | 0.422343E+09 | 0.318917E+09 | 5169.96 | 02-FEB-22:52 | 3159.93 | 0.00 |
| March | 0.00 | 0.00 | 0.650444E+09 | 0.501515E+09 | 5185.04 | 18-MAR-09:42 | 2889.61 | 0.00 |
| April | 0.00 | 0.00 | 0.130762E+10 | 0.102048E+10 | 5249.93 | 24-APR-10:42 | 2875.87 | 0.00 |
| May | 0.00 | 0.00 | 0.313520E+10 | 0.234287E+10 | 5173.84 | 23-MAY-06:52 | 3109.76 | 0.00 |
| June | 0.00 | 0.00 | 0.336610E+10 | 0.252516E+10 | 5177.43 | 06-JUN-07:42 | 3166.67 | 0.00 |
| July | 0.00 | 0.00 | 0.388370E+10 | 0.282304E+10 | 5146.95 | 13-JUL-14:32 | 3315.68 | 0.00 |
| August | 0.00 | 0.00 | 0.390335E+10 | 0.291143E+10 | 5207.54 | 29-AUG-08:62 | 3085.36 | 0.00 |
| September | 0.00 | 0.00 | 0.346579E+10 | 0.255882E+10 | 5259.27 | 05-SEP-08:42 | 2893.85 | 0.00 |
| October | 0.00 | 0.00 | 0.289797E+10 | 0.222238E+10 | 5241.05 | 20-OCT-08:22 | 2976.13 | 0.00 |
| November | 0.00 | 0.00 | 0.130390E+10 | 0.105728E+10 | 5245.49 | 29-NOV-11:52 | 2979.53 | 0.00 |
| December | 0.00 | 0.00 | 0.812909E+09 | 0.647219E+09 | 5263.30 | 12-DEC-11:12 | 2940.05 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.255034E+11 | 0.192042E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.354109E+09 | 0.275080E+09 | 5146.95 | 2875.87 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.390335E+10 | 0.291143E+10 | 5263.30 | 3315.68 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.128007E+10 | 0.114724E+10 | 5554.95 | 31-JAN-11:02 | 3594.98 | 0.00 |
| February | 0.00 | 0.00 | 0.112540E+10 | 0.954331E+09 | 5512.68 | 02-FEB-22:52 | 3722.73 | 0.00 |
| March | 0.00 | 0.00 | 0.107669E+10 | 0.893254E+09 | 5626.40 | 18-MAR-09:32 | 3176.11 | 0.00 |
| April | 0.00 | 0.00 | 0.157586E+10 | 0.126872E+10 | 5647.31 | 30-APR-11:02 | 3126.26 | 0.00 |
| May | 0.00 | 0.00 | 0.315791E+10 | 0.236840E+10 | 5579.35 | 23-MAY-06:52 | 3346.21 | 0.00 |
| June | 0.00 | 0.00 | 0.328625E+10 | 0.245871E+10 | 5576.39 | 06-JUN-07:42 | 3419.53 | 0.00 |
| July | 0.00 | 0.00 | 0.386069E+10 | 0.280452E+10 | 5542.06 | 12-JUL-21:52 | 3616.94 | 0.00 |
| August | 0.00 | 0.00 | 0.404819E+10 | 0.305131E+10 | 5617.75 | 29-AUG-08:62 | 3314.52 | 0.00 |
| September | 0.00 | 0.00 | 0.382661E+10 | 0.289345E+10 | 5632.74 | 05-SEP-08:42 | 3244.59 | 0.00 |
| October | 0.00 | 0.00 | 0.364543E+10 | 0.292131E+10 | 5598.13 | 22-OCT-09:02 | 3358.25 | 0.00 |
| November | 0.00 | 0.00 | 0.224258E+10 | 0.195072E+10 | 5621.59 | 29-NOV-11:52 | 3324.62 | 0.00 |
| December | 0.00 | 0.00 | 0.176929E+10 | 0.156063E+10 | 5607.94 | 12-DEC-10:22 | 3396.82 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.308950E+11 | 0.242726E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.107669E+10 | 0.893254E+09 | 5512.68 | 3126.26 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.404819E+10 | 0.305131E+10 | 5647.31 | 3722.73 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.130555E+10 | 0.117149E+10 | 5602.20 | 31-JAN-11:02 | 3630.84 | 0.00 |
| February | 0.00 | 0.00 | 0.113356E+10 | 0.962020E+09 | 5559.28 | 02-FEB-22:52 | 3760.93 | 0.00 |
| March | 0.00 | 0.00 | 0.111563E+10 | 0.928819E+09 | 5675.24 | 18-MAR-09:32 | 3209.47 | 0.00 |
| April | 0.00 | 0.00 | 0.165712E+10 | 0.134250E+10 | 5704.44 | 30-APR-11:02 | 3219.27 | 0.00 |
| May | 0.00 | 0.00 | 0.340360E+10 | 0.259067E+10 | 5615.26 | 23-MAY-06:52 | 3462.13 | 0.00 |
| June | 0.00 | 0.00 | 0.354445E+10 | 0.269341E+10 | 5611.60 | 06-JUN-07:42 | 3542.90 | 0.00 |
| July | 0.00 | 0.00 | 0.417187E+10 | 0.308699E+10 | 5578.87 | 12-JUL-21:52 | 3674.92 | 0.00 |
| August | 0.00 | 0.00 | 0.433793E+10 | 0.331827E+10 | 5639.83 | 29-AUG-08:62 | 3438.75 | 0.00 |
| September | 0.00 | 0.00 | 0.408850E+10 | 0.313515E+10 | 5654.02 | 26-SEP-09:32 | 3397.05 | 0.00 |
| October | 0.00 | 0.00 | 0.388118E+10 | 0.314314E+10 | 5625.31 | 21-OCT-07:42 | 3514.01 | 0.00 |
| November | 0.00 | 0.00 | 0.234382E+10 | 0.204748E+10 | 5666.13 | 29-NOV-11:52 | 3364.74 | 0.00 |
| December | 0.00 | 0.00 | 0.182427E+10 | 0.161354E+10 | 5635.67 | 13-DEC-10:52 | 3462.67 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.328075E+11 | 0.260335E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.111563E+10 | 0.928819E+09 | 5559.28 | 3209.47 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.433793E+10 | 0.331827E+10 | 5704.44 | 3760.93 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.255668E+10 | 0.227184E+10 | 14119.57 | 31-JAN-11:02 | 8879.39 | 0.00 |
| February | 0.00 | 0.00 | 0.287732E+10 | 0.247957E+10 | 14009.36 | 02-FEB-22:52 | 9214.70 | 0.00 |
| March | 0.00 | 0.00 | 0.313754E+10 | 0.268463E+10 | 14247.02 | 18-MAR-09:32 | 8275.39 | 0.00 |
| April | 0.00 | 0.00 | 0.477004E+10 | 0.400842E+10 | 14329.22 | 30-APR-11:02 | 8023.72 | 0.00 |
| May | 0.00 | 0.00 | 0.827684E+10 | 0.642405E+10 | 14221.09 | 23-MAY-06:52 | 8102.02 | 0.00 |
| June | 0.00 | 0.00 | 0.842517E+10 | 0.654136E+10 | 14149.75 | 06-JUN-07:42 | 8542.68 | 0.00 |
| July | 0.00 | 0.00 | 0.923079E+10 | 0.686804E+10 | 14057.86 | 31-JUL-12:22 | 8984.80 | 0.00 |
| August | 0.00 | 0.00 | 0.912369E+10 | 0.691442E+10 | 14372.50 | 29-AUG-08:62 | 7697.22 | 0.00 |
| September | 0.00 | 0.00 | 0.839389E+10 | 0.633546E+10 | 14543.54 | 05-SEP-08:42 | 7113.76 | 0.00 |
| October | 0.00 | 0.00 | 0.790153E+10 | 0.629517E+10 | 14372.13 | 21-OCT-07:42 | 7816.14 | 0.00 |
| November | 0.00 | 0.00 | 0.449743E+10 | 0.388143E+10 | 14400.38 | 29-NOV-11:52 | 7812.69 | 0.00 |
| December | 0.00 | 0.00 | 0.341450E+10 | 0.297036E+10 | 14389.91 | 12-DEC-10:22 | 7637.19 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.726054E+11 | 0.576747E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.255668E+10 | 0.227184E+10 | 14009.36 | 7113.76 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.923079E+10 | 0.691442E+10 | 14543.54 | 9214.70 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.868833E+09 | 0.677385E+09 | 13539.10 | 31-JAN-11:22 | 8315.53 | 0.00 |
| February | 0.00 | 0.00 | 0.143391E+10 | 0.114108E+10 | 13489.47 | 02-FEB-22:52 | 8413.22 | 0.00 |
| March | 0.00 | 0.00 | 0.223499E+10 | 0.182384E+10 | 13569.68 | 18-MAR-09:42 | 8120.75 | 0.00 |
| April | 0.00 | 0.00 | 0.420101E+10 | 0.347013E+10 | 13690.24 | 24-APR-10:42 | 7867.64 | 0.00 |
| May | 0.00 | 0.00 | 0.823028E+10 | 0.637606E+10 | 13598.27 | 23-MAY-06:52 | 7804.21 | 0.00 |
| June | 0.00 | 0.00 | 0.858038E+10 | 0.667741E+10 | 13568.17 | 06-JUN-07:42 | 8122.27 | 0.00 |
| July | 0.00 | 0.00 | 0.926616E+10 | 0.690165E+10 | 13469.49 | 31-JUL-12:22 | 8513.63 | 0.00 |
| August | 0.00 | 0.00 | 0.881694E+10 | 0.662349E+10 | 13732.90 | 29-AUG-08:62 | 7433.01 | 0.00 |
| September | 0.00 | 0.00 | 0.764752E+10 | 0.564655E+10 | 13954.20 | 05-SEP-08:42 | 6634.35 | 0.00 |
| October | 0.00 | 0.00 | 0.632271E+10 | 0.483011E+10 | 13812.94 | 21-OCT-08:62 | 7131.66 | 0.00 |
| November | 0.00 | 0.00 | 0.255172E+10 | 0.203711E+10 | 13831.86 | 29-NOV-11:52 | 7179.32 | 0.00 |
| December | 0.00 | 0.00 | 0.160812E+10 | 0.125574E+10 | 13829.32 | 12-DEC-11:12 | 7182.69 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.617626E+11 | 0.474606E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.868833E+09 | 0.677385E+09 | 13469.49 | 6634.35 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.926616E+10 | 0.690165E+10 | 13954.20 | 8513.63 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.251769E+10 | 0.223712E+10 | 13168.20 | 31-JAN-11:02 | 8294.88 | 0.00 |
| February | 0.00 | 0.00 | 0.280437E+10 | 0.241552E+10 | 13076.63 | 02-FEB-22:52 | 8567.25 | 0.00 |
| March | 0.00 | 0.00 | 0.318062E+10 | 0.272578E+10 | 13286.81 | 18-MAR-09:32 | 7730.74 | 0.00 |
| April | 0.00 | 0.00 | 0.473681E+10 | 0.397924E+10 | 13362.09 | 30-APR-11:02 | 7482.79 | 0.00 |
| May | 0.00 | 0.00 | 0.845065E+10 | 0.658021E+10 | 13266.95 | 23-MAY-06:52 | 7575.30 | 0.00 |
| June | 0.00 | 0.00 | 0.853809E+10 | 0.664357E+10 | 13210.81 | 06-JUN-07:42 | 7989.91 | 0.00 |
| July | 0.00 | 0.00 | 0.941483E+10 | 0.703887E+10 | 13109.92 | 12-JUL-21:52 | 8424.57 | 0.00 |
| August | 0.00 | 0.00 | 0.916107E+10 | 0.694840E+10 | 13410.64 | 29-AUG-08:62 | 7303.97 | 0.00 |
| September | 0.00 | 0.00 | 0.838706E+10 | 0.632959E+10 | 13567.75 | 05-SEP-08:42 | 6665.72 | 0.00 |
| October | 0.00 | 0.00 | 0.785016E+10 | 0.624417E+10 | 13413.69 | 21-OCT-07:42 | 7361.09 | 0.00 |
| November | 0.00 | 0.00 | 0.447821E+10 | 0.386577E+10 | 13424.29 | 29-NOV-11:52 | 7318.42 | 0.00 |
| December | 0.00 | 0.00 | 0.328353E+10 | 0.284638E+10 | 13419.56 | 12-DEC-10:22 | 7069.50 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.728031E+11 | 0.578546E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.251769E+10 | 0.223712E+10 | 13076.63 | 6665.72 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.941483E+10 | 0.703887E+10 | 13567.75 | 8567.25 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.808513E+09 | 0.622536E+09 | 12594.79 | 30-JAN-22:42 | 7627.60 | 0.00 |
| February | 0.00 | 0.00 | 0.134394E+10 | 0.106070E+10 | 12587.98 | 02-FEB-22:52 | 7589.75 | 0.00 |
| March | 0.00 | 0.00 | 0.225796E+10 | 0.184091E+10 | 12615.95 | 18-MAR-09:42 | 7568.41 | 0.00 |
| April | 0.00 | 0.00 | 0.418286E+10 | 0.345005E+10 | 12704.59 | 30-APR-11:52 | 7279.49 | 0.00 |
| May | 0.00 | 0.00 | 0.840885E+10 | 0.653269E+10 | 12643.95 | 23-MAY-06:52 | 7266.71 | 0.00 |
| June | 0.00 | 0.00 | 0.869666E+10 | 0.677984E+10 | 12625.57 | 06-JUN-07:42 | 7565.33 | 0.00 |
| July | 0.00 | 0.00 | 0.945462E+10 | 0.707296E+10 | 12489.84 | 12-JUL-21:52 | 8072.70 | 0.00 |
| August | 0.00 | 0.00 | 0.885915E+10 | 0.665833E+10 | 12771.90 | 29-AUG-08:62 | 7030.29 | 0.00 |
| September | 0.00 | 0.00 | 0.764746E+10 | 0.564323E+10 | 12975.59 | 05-SEP-08:42 | 6190.90 | 0.00 |
| October | 0.00 | 0.00 | 0.627659E+10 | 0.478025E+10 | 12852.88 | 21-OCT-08:62 | 6744.44 | 0.00 |
| November | 0.00 | 0.00 | 0.252640E+10 | 0.201389E+10 | 12850.64 | 29-NOV-11:52 | 6762.23 | 0.00 |
| December | 0.00 | 0.00 | 0.149743E+10 | 0.115323E+10 | 12857.10 | 12-DEC-11:12 | 6679.56 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.619604E+11 | 0.476086E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.808513E+09 | 0.622536E+09 | 12489.84 | 6190.90 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.945462E+10 | 0.707296E+10 | 12975.59 | 8072.70 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.959983E+09 | 0.767138E+09 | 11403.06 | 19-JAN-22:52 | 6919.61 | 0.00 |
| February | 0.00 | 0.00 | 0.146265E+10 | 0.117010E+10 | 11378.16 | 02-FEB-22:52 | 7013.42 | 0.00 |
| March | 0.00 | 0.00 | 0.219897E+10 | 0.180270E+10 | 11408.41 | 18-MAR-09:42 | 6845.58 | 0.00 |
| April | 0.00 | 0.00 | 0.367831E+10 | 0.299804E+10 | 11522.90 | 24-APR-10:42 | 6557.41 | 0.00 |
| May | 0.00 | 0.00 | 0.702491E+10 | 0.533354E+10 | 11429.47 | 23-MAY-06:52 | 6616.35 | 0.00 |
| June | 0.00 | 0.00 | 0.724983E+10 | 0.549938E+10 | 11422.51 | 06-JUN-07:42 | 6750.64 | 0.00 |
| July | 0.00 | 0.00 | 0.791132E+10 | 0.574313E+10 | 11356.17 | 12-JUL-21:52 | 7177.95 | 0.00 |
| August | 0.00 | 0.00 | 0.747335E+10 | 0.548074E+10 | 11538.98 | 29-AUG-08:62 | 6287.39 | 0.00 |
| September | 0.00 | 0.00 | 0.659102E+10 | 0.476390E+10 | 11719.68 | 05-SEP-08:42 | 5625.47 | 0.00 |
| October | 0.00 | 0.00 | 0.545457E+10 | 0.410013E+10 | 11602.51 | 21-OCT-08:62 | 6060.86 | 0.00 |
| November | 0.00 | 0.00 | 0.253935E+10 | 0.204460E+10 | 11622.25 | 29-NOV-11:52 | 6146.33 | 0.00 |
| December | 0.00 | 0.00 | 0.169330E+10 | 0.134730E+10 | 11628.44 | 12-DEC-11:12 | 6163.11 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.542376E+11 | 0.410507E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.959983E+09 | 0.767138E+09 | 11356.17 | 5625.47 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.791132E+10 | 0.574313E+10 | 11719.68 | 7177.95 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.958783E+09 | 0.766102E+09 | 11385.00 | 19-JAN-22:52 | 6906.63 | 0.00 |
| February | 0.00 | 0.00 | 0.145967E+10 | 0.116745E+10 | 11359.91 | 02-FEB-22:52 | 6996.55 | 0.00 |
| March | 0.00 | 0.00 | 0.220431E+10 | 0.180745E+10 | 11390.41 | 18-MAR-09:42 | 6833.63 | 0.00 |
| April | 0.00 | 0.00 | 0.368571E+10 | 0.300489E+10 | 11505.10 | 24-APR-10:42 | 6549.18 | 0.00 |
| May | 0.00 | 0.00 | 0.703268E+10 | 0.534035E+10 | 11411.47 | 23-MAY-06:52 | 6605.75 | 0.00 |
| June | 0.00 | 0.00 | 0.725518E+10 | 0.550403E+10 | 11404.72 | 06-JUN-07:42 | 6738.25 | 0.00 |
| July | 0.00 | 0.00 | 0.791866E+10 | 0.574956E+10 | 11339.97 | 12-JUL-21:52 | 7161.17 | 0.00 |
| August | 0.00 | 0.00 | 0.747557E+10 | 0.548256E+10 | 11521.00 | 29-AUG-08:62 | 6279.41 | 0.00 |
| September | 0.00 | 0.00 | 0.659185E+10 | 0.476446E+10 | 11701.26 | 05-SEP-08:42 | 5616.79 | 0.00 |
| October | 0.00 | 0.00 | 0.545434E+10 | 0.409966E+10 | 11584.45 | 21-OCT-08:62 | 6051.20 | 0.00 |
| November | 0.00 | 0.00 | 0.254002E+10 | 0.204495E+10 | 11604.09 | 29-NOV-11:52 | 6137.14 | 0.00 |
| December | 0.00 | 0.00 | 0.168452E+10 | 0.133900E+10 | 11610.09 | 12-DEC-11:12 | 6152.44 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.542613E+11 | 0.410705E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.958783E+09 | 0.766102E+09 | 11339.97 | 5616.79 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.791866E+10 | 0.574956E+10 | 11701.26 | 7161.17 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.306097E+10 | 0.277226E+10 | 12016.05 | 31-JAN-11:02 | 7689.15 | 0.00 |
| February | 0.00 | 0.00 | 0.309328E+10 | 0.269990E+10 | 11933.02 | 02-FEB-22:52 | 7935.26 | 0.00 |
| March | 0.00 | 0.00 | 0.317568E+10 | 0.273885E+10 | 12147.68 | 18-MAR-09:32 | 7086.84 | 0.00 |
| April | 0.00 | 0.00 | 0.426017E+10 | 0.354794E+10 | 12216.39 | 30-APR-11:02 | 6840.50 | 0.00 |
| May | 0.00 | 0.00 | 0.707149E+10 | 0.538207E+10 | 12115.69 | 23-MAY-06:52 | 6963.23 | 0.00 |
| June | 0.00 | 0.00 | 0.709115E+10 | 0.536267E+10 | 12072.39 | 06-JUN-07:42 | 7205.81 | 0.00 |
| July | 0.00 | 0.00 | 0.787496E+10 | 0.571001E+10 | 12033.49 | 12-JUL-21:52 | 7593.89 | 0.00 |
| August | 0.00 | 0.00 | 0.778405E+10 | 0.577243E+10 | 12241.88 | 29-AUG-08:62 | 6598.87 | 0.00 |
| September | 0.00 | 0.00 | 0.735007E+10 | 0.545748E+10 | 12377.43 | 05-SEP-08:42 | 6130.50 | 0.00 |
| October | 0.00 | 0.00 | 0.704848E+10 | 0.557509E+10 | 12232.30 | 21-OCT-07:42 | 6761.05 | 0.00 |
| November | 0.00 | 0.00 | 0.454812E+10 | 0.395244E+10 | 12265.10 | 29-NOV-11:52 | 6740.18 | 0.00 |
| December | 0.00 | 0.00 | 0.375052E+10 | 0.331582E+10 | 12254.90 | 12-DEC-10:22 | 6761.32 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.661089E+11 | 0.522869E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.306097E+10 | 0.269990E+10 | 11933.02 | 6130.50 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.787496E+10 | 0.577243E+10 | 12377.43 | 7935.26 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.306240E+10 | 0.277364E+10 | 12000.22 | 31-JAN-11:02 | 7678.22 | 0.00 |
| February | 0.00 | 0.00 | 0.309235E+10 | 0.269912E+10 | 11917.44 | 02-FEB-22:52 | 7923.43 | 0.00 |
| March | 0.00 | 0.00 | 0.318245E+10 | 0.274509E+10 | 12131.72 | 18-MAR-09:32 | 7076.67 | 0.00 |
| April | 0.00 | 0.00 | 0.426708E+10 | 0.355432E+10 | 12200.16 | 30-APR-11:02 | 6829.72 | 0.00 |
| May | 0.00 | 0.00 | 0.707932E+10 | 0.538891E+10 | 12099.73 | 23-MAY-06:52 | 6953.87 | 0.00 |
| June | 0.00 | 0.00 | 0.709667E+10 | 0.536746E+10 | 12056.72 | 06-JUN-07:42 | 7194.38 | 0.00 |
| July | 0.00 | 0.00 | 0.788241E+10 | 0.571653E+10 | 12018.85 | 12-JUL-21:52 | 7579.74 | 0.00 |
| August | 0.00 | 0.00 | 0.778619E+10 | 0.577420E+10 | 12225.97 | 29-AUG-08:62 | 6592.17 | 0.00 |
| September | 0.00 | 0.00 | 0.735065E+10 | 0.545779E+10 | 12361.18 | 05-SEP-08:42 | 6122.57 | 0.00 |
| October | 0.00 | 0.00 | 0.704864E+10 | 0.557503E+10 | 12216.34 | 21-OCT-07:42 | 6751.48 | 0.00 |
| November | 0.00 | 0.00 | 0.455071E+10 | 0.395484E+10 | 12248.65 | 29-NOV-11:52 | 6731.74 | 0.00 |
| December | 0.00 | 0.00 | 0.374365E+10 | 0.330896E+10 | 12238.72 | 12-DEC-10:22 | 6751.34 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.661425E+11 | 0.523159E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.306240E+10 | 0.269912E+10 | 11917.44 | 6122.57 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.788241E+10 | 0.577420E+10 | 12361.18 | 7923.43 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.856541E+09 | 0.740109E+09 | 7761.68 | 31-JAN-11:02 | 4698.91 | 0.00 |
| February | 0.00 | 0.00 | 0.107111E+10 | 0.909793E+09 | 7722.03 | 02-FEB-22:52 | 4943.14 | 0.00 |
| March | 0.00 | 0.00 | 0.127939E+10 | 0.107988E+10 | 7832.22 | 18-MAR-09:32 | 4347.25 | 0.00 |
| April | 0.00 | 0.00 | 0.226554E+10 | 0.190409E+10 | 7869.30 | 30-APR-11:02 | 4404.15 | 0.00 |
| May | 0.00 | 0.00 | 0.450788E+10 | 0.354489E+10 | 7861.50 | 23-MAY-06:52 | 4378.19 | 0.00 |
| June | 0.00 | 0.00 | 0.466790E+10 | 0.369023E+10 | 7821.53 | 06-JUN-07:42 | 4566.02 | 0.00 |
| July | 0.00 | 0.00 | 0.509184E+10 | 0.385593E+10 | 7755.83 | 12-JUL-06:52 | 4640.12 | 0.00 |
| August | 0.00 | 0.00 | 0.500756E+10 | 0.385136E+10 | 7937.68 | 29-AUG-08:62 | 4101.78 | 0.00 |
| September | 0.00 | 0.00 | 0.445394E+10 | 0.338925E+10 | 8022.78 | 05-SEP-08:42 | 3824.15 | 0.00 |
| October | 0.00 | 0.00 | 0.408208E+10 | 0.325961E+10 | 7959.71 | 21-OCT-07:42 | 4089.42 | 0.00 |
| November | 0.00 | 0.00 | 0.184214E+10 | 0.156557E+10 | 7914.24 | 29-NOV-11:52 | 4255.28 | 0.00 |
| December | 0.00 | 0.00 | 0.129778E+10 | 0.110223E+10 | 7927.75 | 13-DEC-10:52 | 4214.18 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.364237E+11 | 0.288929E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.856541E+09 | 0.740109E+09 | 7722.03 | 3824.15 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.509184E+10 | 0.385593E+10 | 8022.78 | 4943.14 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.327756E+09 | 0.248788E+09 | 7550.50 | 31-JAN-11:22 | 4581.98 | 0.00 |
| February | 0.00 | 0.00 | 0.516536E+09 | 0.401905E+09 | 7525.17 | 02-FEB-22:52 | 4641.67 | 0.00 |
| March | 0.00 | 0.00 | 0.904269E+09 | 0.722939E+09 | 7570.56 | 18-MAR-09:42 | 4328.70 | 0.00 |
| April | 0.00 | 0.00 | 0.197710E+10 | 0.162950E+10 | 7633.99 | 24-APR-10:42 | 4329.36 | 0.00 |
| May | 0.00 | 0.00 | 0.448759E+10 | 0.352101E+10 | 7622.27 | 23-MAY-06:52 | 4280.18 | 0.00 |
| June | 0.00 | 0.00 | 0.474927E+10 | 0.376034E+10 | 7603.57 | 06-JUN-07:42 | 4379.87 | 0.00 |
| July | 0.00 | 0.00 | 0.511345E+10 | 0.387515E+10 | 7523.67 | 12-JUL-06:52 | 4527.85 | 0.00 |
| August | 0.00 | 0.00 | 0.484429E+10 | 0.369320E+10 | 7691.61 | 29-AUG-08:62 | 4035.56 | 0.00 |
| September | 0.00 | 0.00 | 0.406438E+10 | 0.302644E+10 | 7804.66 | 05-SEP-08:42 | 3640.18 | 0.00 |
| October | 0.00 | 0.00 | 0.327351E+10 | 0.250661E+10 | 7747.55 | 21-OCT-08:62 | 3832.50 | 0.00 |
| November | 0.00 | 0.00 | 0.984303E+09 | 0.758564E+09 | 7717.28 | 29-NOV-11:52 | 3925.72 | 0.00 |
| December | 0.00 | 0.00 | 0.625863E+09 | 0.473014E+09 | 7711.65 | 12-DEC-11:12 | 3858.16 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.318683E+11 | 0.246175E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.327756E+09 | 0.248788E+09 | 7523.67 | 3640.18 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.511345E+10 | 0.387515E+10 | 7804.66 | 4641.67 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.805906E+09 | 0.691785E+09 | 7034.27 | 31-JAN-11:02 | 4271.57 | 0.00 |
| February | 0.00 | 0.00 | 0.102515E+10 | 0.868041E+09 | 7007.15 | 02-FEB-22:52 | 4441.82 | 0.00 |
| March | 0.00 | 0.00 | 0.128460E+10 | 0.108309E+10 | 7106.74 | 18-MAR-09:32 | 4002.68 | 0.00 |
| April | 0.00 | 0.00 | 0.222841E+10 | 0.186858E+10 | 7129.60 | 30-APR-11:02 | 3989.68 | 0.00 |
| May | 0.00 | 0.00 | 0.459698E+10 | 0.362185E+10 | 7125.39 | 23-MAY-06:52 | 3983.81 | 0.00 |
| June | 0.00 | 0.00 | 0.472680E+10 | 0.374179E+10 | 7077.22 | 06-JUN-07:42 | 4173.50 | 0.00 |
| July | 0.00 | 0.00 | 0.518970E+10 | 0.394579E+10 | 7032.06 | 12-JUL-06:52 | 4222.56 | 0.00 |
| August | 0.00 | 0.00 | 0.502430E+10 | 0.386513E+10 | 7177.77 | 29-AUG-08:62 | 3800.42 | 0.00 |
| September | 0.00 | 0.00 | 0.445064E+10 | 0.338519E+10 | 7263.39 | 05-SEP-08:42 | 3485.95 | 0.00 |
| October | 0.00 | 0.00 | 0.405065E+10 | 0.322608E+10 | 7200.74 | 21-OCT-07:42 | 3750.32 | 0.00 |
| November | 0.00 | 0.00 | 0.182137E+10 | 0.154529E+10 | 7160.64 | 29-NOV-11:52 | 3894.19 | 0.00 |
| December | 0.00 | 0.00 | 0.122886E+10 | 0.103671E+10 | 7178.25 | 13-DEC-10:52 | 3838.56 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.364334E+11 | 0.288793E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.805906E+09 | 0.691785E+09 | 7007.15 | 3485.95 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.518970E+10 | 0.394579E+10 | 7263.39 | 4441.82 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.299631E+09 | 0.225063E+09 | 6837.59 | 19-JAN-11:02 | 4392.64 | 0.00 |
| February | 0.00 | 0.00 | 0.470611E+09 | 0.362767E+09 | 6797.40 | 02-FEB-22:52 | 4168.43 | 0.00 |
| March | 0.00 | 0.00 | 0.918296E+09 | 0.734130E+09 | 6840.72 | 18-MAR-09:42 | 3940.99 | 0.00 |
| April | 0.00 | 0.00 | 0.194179E+10 | 0.159548E+10 | 6870.95 | 30-APR-11:52 | 3957.05 | 0.00 |
| May | 0.00 | 0.00 | 0.457673E+10 | 0.359823E+10 | 6884.74 | 23-MAY-06:52 | 3880.79 | 0.00 |
| June | 0.00 | 0.00 | 0.480768E+10 | 0.381197E+10 | 6861.62 | 06-JUN-07:42 | 3970.04 | 0.00 |
| July | 0.00 | 0.00 | 0.521150E+10 | 0.396502E+10 | 6798.39 | 12-JUL-06:52 | 4103.78 | 0.00 |
| August | 0.00 | 0.00 | 0.486160E+10 | 0.370707E+10 | 6928.37 | 29-AUG-08:62 | 3719.37 | 0.00 |
| September | 0.00 | 0.00 | 0.406272E+10 | 0.302275E+10 | 7041.49 | 05-SEP-08:42 | 3307.16 | 0.00 |
| October | 0.00 | 0.00 | 0.324298E+10 | 0.247416E+10 | 6984.79 | 21-OCT-08:62 | 3539.33 | 0.00 |
| November | 0.00 | 0.00 | 0.959240E+09 | 0.734445E+09 | 6952.88 | 29-NOV-11:52 | 3659.54 | 0.00 |
| December | 0.00 | 0.00 | 0.580234E+09 | 0.431441E+09 | 6965.93 | 12-DEC-11:12 | 3511.24 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.319330E+11 | 0.246625E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.299631E+09 | 0.225063E+09 | 6797.40 | 3307.16 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.521150E+10 | 0.396502E+10 | 7041.49 | 4392.64 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.306872E+09 | 0.229125E+09 | 6353.28 | 31-JAN-11:22 | 3881.89 | 0.00 |
| February | 0.00 | 0.00 | 0.471683E+09 | 0.359090E+09 | 6329.43 | 02-FEB-22:52 | 3950.69 | 0.00 |
| March | 0.00 | 0.00 | 0.825793E+09 | 0.649929E+09 | 6369.58 | 18-MAR-09:42 | 3665.52 | 0.00 |
| April | 0.00 | 0.00 | 0.170825E+10 | 0.138237E+10 | 6422.34 | 24-APR-10:42 | 3650.99 | 0.00 |
| May | 0.00 | 0.00 | 0.386849E+10 | 0.298636E+10 | 6402.03 | 23-MAY-06:52 | 3660.94 | 0.00 |
| June | 0.00 | 0.00 | 0.406700E+10 | 0.315420E+10 | 6383.96 | 06-JUN-07:42 | 3740.10 | 0.00 |
| July | 0.00 | 0.00 | 0.442065E+10 | 0.328545E+10 | 6326.56 | 12-JUL-06:52 | 3847.16 | 0.00 |
| August | 0.00 | 0.00 | 0.414834E+10 | 0.310407E+10 | 6460.64 | 29-AUG-08:62 | 3453.24 | 0.00 |
| September | 0.00 | 0.00 | 0.352473E+10 | 0.257894E+10 | 6555.09 | 05-SEP-08:42 | 3109.24 | 0.00 |
| October | 0.00 | 0.00 | 0.281174E+10 | 0.211738E+10 | 6507.01 | 21-OCT-08:62 | 3288.69 | 0.00 |
| November | 0.00 | 0.00 | 0.904089E+09 | 0.686067E+09 | 6480.69 | 29-NOV-11:52 | 3408.25 | 0.00 |
| December | 0.00 | 0.00 | 0.567848E+09 | 0.420181E+09 | 6491.98 | 12-DEC-11:12 | 3329.61 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.276255E+11 | 0.209532E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.306872E+09 | 0.229125E+09 | 6326.56 | 3109.24 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.442065E+10 | 0.328545E+10 | 6555.09 | 3950.69 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.305488E+09 | 0.227978E+09 | 6330.56 | 19-JAN-22:52 | 3854.92 | 0.00 |
| February | 0.00 | 0.00 | 0.469909E+09 | 0.357686E+09 | 6306.19 | 02-FEB-22:52 | 3933.86 | 0.00 |
| March | 0.00 | 0.00 | 0.829067E+09 | 0.652762E+09 | 6345.86 | 18-MAR-09:42 | 3650.13 | 0.00 |
| April | 0.00 | 0.00 | 0.171067E+10 | 0.138456E+10 | 6397.91 | 24-APR-10:42 | 3638.57 | 0.00 |
| May | 0.00 | 0.00 | 0.387322E+10 | 0.299032E+10 | 6378.23 | 23-MAY-06:52 | 3647.13 | 0.00 |
| June | 0.00 | 0.00 | 0.407025E+10 | 0.315691E+10 | 6360.35 | 06-JUN-07:42 | 3724.82 | 0.00 |
| July | 0.00 | 0.00 | 0.442492E+10 | 0.328914E+10 | 6303.08 | 12-JUL-06:52 | 3831.98 | 0.00 |
| August | 0.00 | 0.00 | 0.414961E+10 | 0.310499E+10 | 6436.14 | 29-AUG-08:62 | 3441.33 | 0.00 |
| September | 0.00 | 0.00 | 0.352544E+10 | 0.257932E+10 | 6530.53 | 05-SEP-08:42 | 3097.73 | 0.00 |
| October | 0.00 | 0.00 | 0.281152E+10 | 0.211697E+10 | 6483.06 | 21-OCT-08:62 | 3277.35 | 0.00 |
| November | 0.00 | 0.00 | 0.904858E+09 | 0.686672E+09 | 6456.30 | 29-NOV-11:52 | 3395.89 | 0.00 |
| December | 0.00 | 0.00 | 0.566082E+09 | 0.418599E+09 | 6467.83 | 12-DEC-11:12 | 3316.40 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.276410E+11 | 0.209659E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.305488E+09 | 0.227978E+09 | 6303.08 | 3097.73 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.442492E+10 | 0.328914E+10 | 6530.53 | 3933.86 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.877961E+09 | 0.759814E+09 | 6592.37 | 31-JAN-11:02 | 4027.21 | 0.00 |
| February | 0.00 | 0.00 | 0.105993E+10 | 0.896662E+09 | 6537.21 | 02-FEB-22:52 | 4280.25 | 0.00 |
| March | 0.00 | 0.00 | 0.121016E+10 | 0.101424E+10 | 6659.02 | 18-MAR-09:32 | 3740.89 | 0.00 |
| April | 0.00 | 0.00 | 0.199756E+10 | 0.165657E+10 | 6680.96 | 30-APR-11:02 | 3762.43 | 0.00 |
| May | 0.00 | 0.00 | 0.388853E+10 | 0.300999E+10 | 6664.71 | 23-MAY-06:52 | 3779.68 | 0.00 |
| June | 0.00 | 0.00 | 0.398377E+10 | 0.308325E+10 | 6629.05 | 06-JUN-07:42 | 3932.15 | 0.00 |
| July | 0.00 | 0.00 | 0.439787E+10 | 0.326594E+10 | 6582.24 | 12-JUL-06:52 | 3981.47 | 0.00 |
| August | 0.00 | 0.00 | 0.431389E+10 | 0.326330E+10 | 6731.93 | 29-AUG-08:62 | 3537.80 | 0.00 |
| September | 0.00 | 0.00 | 0.391938E+10 | 0.294526E+10 | 6798.69 | 05-SEP-08:42 | 3304.65 | 0.00 |
| October | 0.00 | 0.00 | 0.363401E+10 | 0.288210E+10 | 6735.14 | 21-OCT-07:42 | 3570.94 | 0.00 |
| November | 0.00 | 0.00 | 0.181420E+10 | 0.154098E+10 | 6710.33 | 29-NOV-11:52 | 3659.34 | 0.00 |
| December | 0.00 | 0.00 | 0.129379E+10 | 0.109991E+10 | 6724.66 | 13-DEC-10:52 | 3614.55 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.323911E+11 | 0.254180E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.877961E+09 | 0.759814E+09 | 6537.21 | 3304.65 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.439787E+10 | 0.326594E+10 | 6798.69 | 4280.25 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.880694E+09 | 0.762505E+09 | 6568.91 | 31-JAN-11:02 | 4011.72 | 0.00 |
| February | 0.00 | 0.00 | 0.106038E+10 | 0.897174E+09 | 6514.14 | 02-FEB-22:52 | 4263.06 | 0.00 |
| March | 0.00 | 0.00 | 0.121575E+10 | 0.101876E+10 | 6635.24 | 18-MAR-09:32 | 3726.15 | 0.00 |
| April | 0.00 | 0.00 | 0.200056E+10 | 0.165934E+10 | 6657.28 | 30-APR-11:02 | 3747.69 | 0.00 |
| May | 0.00 | 0.00 | 0.389332E+10 | 0.301403E+10 | 6640.97 | 23-MAY-06:52 | 3766.02 | 0.00 |
| June | 0.00 | 0.00 | 0.398717E+10 | 0.308609E+10 | 6605.58 | 06-JUN-07:42 | 3916.65 | 0.00 |
| July | 0.00 | 0.00 | 0.440224E+10 | 0.326967E+10 | 6558.83 | 12-JUL-06:52 | 3966.51 | 0.00 |
| August | 0.00 | 0.00 | 0.431520E+10 | 0.326405E+10 | 6708.28 | 29-AUG-08:62 | 3527.46 | 0.00 |
| September | 0.00 | 0.00 | 0.391996E+10 | 0.294556E+10 | 6774.28 | 05-SEP-08:42 | 3292.90 | 0.00 |
| October | 0.00 | 0.00 | 0.363425E+10 | 0.288201E+10 | 6711.03 | 21-OCT-07:42 | 3557.88 | 0.00 |
| November | 0.00 | 0.00 | 0.181649E+10 | 0.154307E+10 | 6686.09 | 29-NOV-11:52 | 3646.71 | 0.00 |
| December | 0.00 | 0.00 | 0.129208E+10 | 0.109828E+10 | 6700.64 | 13-DEC-10:52 | 3601.17 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.324181E+11 | 0.254405E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.880694E+09 | 0.762505E+09 | 6514.14 | 3292.90 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.440224E+10 | 0.326967E+10 | 6774.28 | 4263.06 | 0.00 |
Report: PlantLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 9837.00 | 18792.91 | 23-JAN-07:40 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 9757.04 | 18763.47 | 01-FEB-07:50 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 9396.68 | 18336.08 | 01-MAR-07:40 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 8833.40 | 17383.11 | 01-APR-06:50 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 8224.08 | 16226.56 | 01-MAY-06:50 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 7732.06 | 15114.50 | 01-JUN-06:50 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 7491.61 | 14402.98 | 01-JUL-06:50 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 7569.43 | 14688.22 | 31-AUG-06:50 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 7942.27 | 15605.64 | 30-SEP-06:50 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 8509.77 | 16796.57 | 31-OCT-06:50 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 9118.07 | 17879.55 | 30-NOV-07:50 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 9603.39 | 18619.05 | 31-DEC-07:50 |
| Annual Sum or Average | 0.00 | 8661.81 | ||||
| Minimum of Months | 0.00 | 0.00 | 7491.61 | 14402.98 | ||
| Maximum of Months | 0.00 | 0.00 | 9837.00 | 18792.91 |
Report: FanReportMonthly
For: SPLIT GSW SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 70924260.74 | 0.55 | 356.35 | 01-JAN-10:52 | 0.91 |
| February | 64004363.11 | 0.48 | 356.35 | 01-FEB-13:22 | 0.91 |
| March | 63751110.08 | 0.45 | 356.35 | 01-MAR-19:42 | 0.91 |
| April | 0.106537E+09 | 0.62 | 356.35 | 01-APR-11:22 | 0.90 |
| May | 0.231329E+09 | 0.95 | 356.35 | 02-MAY-07:52 | 0.90 |
| June | 0.247278E+09 | 0.98 | 356.35 | 01-JUN-07:32 | 0.90 |
| July | 0.288896E+09 | 0.99 | 356.35 | 11-JUL-21:22 | 0.90 |
| August | 0.309278E+09 | 0.96 | 356.35 | 01-AUG-06:52 | 0.90 |
| September | 0.284737E+09 | 0.89 | 356.35 | 01-SEP-07:02 | 0.91 |
| October | 0.268665E+09 | 0.82 | 356.35 | 01-OCT-09:52 | 0.91 |
| November | 0.149988E+09 | 0.68 | 356.35 | 01-NOV-07:32 | 0.90 |
| December | 0.109487E+09 | 0.65 | 356.35 | 01-DEC-11:32 | 0.91 |
| Annual Sum or Average | 0.219487E+10 | 0.75 | |||
| Minimum of Months | 63751110.08 | 0.45 | 356.35 | 0.90 | |
| Maximum of Months | 0.309278E+09 | 0.99 | 356.35 | 0.91 |
Report: FanReportMonthly
For: G SW APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: G SW APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: SPLIT GNW SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 21739246.14 | 0.19 | 338.81 | 01-JAN-12:42 | 0.91 |
| February | 26488557.09 | 0.23 | 338.81 | 01-FEB-14:12 | 0.91 |
| March | 39045425.44 | 0.34 | 338.81 | 01-MAR-19:42 | 0.91 |
| April | 89107907.16 | 0.57 | 338.81 | 01-APR-11:52 | 0.91 |
| May | 0.228822E+09 | 0.95 | 338.81 | 02-MAY-07:52 | 0.90 |
| June | 0.251294E+09 | 0.98 | 338.81 | 01-JUN-07:32 | 0.90 |
| July | 0.289005E+09 | 0.99 | 338.81 | 11-JUL-21:22 | 0.90 |
| August | 0.298572E+09 | 0.96 | 338.81 | 01-AUG-06:52 | 0.90 |
| September | 0.260729E+09 | 0.89 | 338.81 | 01-SEP-07:02 | 0.91 |
| October | 0.219803E+09 | 0.80 | 338.81 | 01-OCT-10:52 | 0.91 |
| November | 89152154.26 | 0.60 | 338.81 | 01-NOV-07:42 | 0.90 |
| December | 52166498.96 | 0.37 | 338.81 | 01-DEC-14:42 | 0.91 |
| Annual Sum or Average | 0.186593E+10 | 0.66 | |||
| Minimum of Months | 21739246.14 | 0.19 | 338.81 | 0.90 | |
| Maximum of Months | 0.298572E+09 | 0.99 | 338.81 | 0.91 |
Report: FanReportMonthly
For: G NW APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: G NW APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: SPLIT OFFICE SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.105982E+10 | 0.92 | 412.31 | 01-JAN-00:10 | 0.91 |
| February | 0.956655E+09 | 0.92 | 412.31 | 01-FEB-00:10 | 0.90 |
| March | 0.105219E+10 | 0.92 | 412.31 | 01-MAR-00:10 | 0.91 |
| April | 0.102888E+10 | 0.91 | 412.31 | 01-APR-00:10 | 0.90 |
| May | 0.107231E+10 | 0.91 | 412.31 | 01-MAY-00:10 | 0.91 |
| June | 0.103884E+10 | 0.91 | 412.31 | 01-JUN-00:10 | 0.90 |
| July | 0.108128E+10 | 0.90 | 412.31 | 01-JUL-00:10 | 0.90 |
| August | 0.107968E+10 | 0.91 | 412.31 | 01-AUG-00:10 | 0.90 |
| September | 0.104571E+10 | 0.91 | 412.31 | 01-SEP-00:10 | 0.90 |
| October | 0.108025E+10 | 0.91 | 412.31 | 01-OCT-00:10 | 0.90 |
| November | 0.103623E+10 | 0.92 | 412.31 | 01-NOV-00:10 | 0.90 |
| December | 0.106411E+10 | 0.92 | 412.31 | 01-DEC-00:10 | 0.91 |
| Annual Sum or Average | 0.125960E+11 | 0.91 | |||
| Minimum of Months | 0.956655E+09 | 0.90 | 412.31 | 0.90 | |
| Maximum of Months | 0.108128E+10 | 0.92 | 412.31 | 0.91 |
Report: FanReportMonthly
For: SPLIT GNE SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 20080516.70 | 0.18 | 314.49 | 01-JAN-12:42 | 0.91 |
| February | 23678199.92 | 0.23 | 314.49 | 01-FEB-14:12 | 0.91 |
| March | 39384652.88 | 0.34 | 314.49 | 01-MAR-19:42 | 0.91 |
| April | 86910397.34 | 0.57 | 314.49 | 01-APR-11:52 | 0.91 |
| May | 0.230398E+09 | 0.95 | 314.49 | 02-MAY-07:52 | 0.90 |
| June | 0.250573E+09 | 0.98 | 314.49 | 01-JUN-07:32 | 0.90 |
| July | 0.289807E+09 | 0.99 | 314.49 | 11-JUL-21:22 | 0.90 |
| August | 0.294635E+09 | 0.96 | 314.49 | 01-AUG-06:52 | 0.90 |
| September | 0.256201E+09 | 0.89 | 314.49 | 01-SEP-07:02 | 0.91 |
| October | 0.214685E+09 | 0.79 | 314.49 | 01-OCT-10:52 | 0.91 |
| November | 87228517.32 | 0.59 | 314.49 | 01-NOV-07:42 | 0.90 |
| December | 48247551.60 | 0.36 | 314.49 | 01-DEC-14:42 | 0.91 |
| Annual Sum or Average | 0.184183E+10 | 0.65 | |||
| Minimum of Months | 20080516.70 | 0.18 | 314.49 | 0.90 | |
| Maximum of Months | 0.294635E+09 | 0.99 | 314.49 | 0.91 |
Report: FanReportMonthly
For: G NE APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: G NE APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: SPLIT GN1 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 22711991.05 | 0.29 | 275.50 | 01-JAN-12:42 | 0.91 |
| February | 26901358.44 | 0.31 | 275.50 | 01-FEB-14:12 | 0.91 |
| March | 41534569.59 | 0.42 | 275.50 | 01-MAR-19:42 | 0.91 |
| April | 83560299.27 | 0.60 | 275.50 | 01-APR-11:52 | 0.91 |
| May | 0.199878E+09 | 0.95 | 275.50 | 02-MAY-07:52 | 0.90 |
| June | 0.214892E+09 | 0.98 | 275.50 | 01-JUN-07:32 | 0.90 |
| July | 0.245472E+09 | 0.99 | 275.50 | 11-JUL-21:22 | 0.90 |
| August | 0.247175E+09 | 0.96 | 275.50 | 01-AUG-06:52 | 0.90 |
| September | 0.218040E+09 | 0.89 | 275.50 | 01-SEP-07:02 | 0.90 |
| October | 0.183903E+09 | 0.80 | 275.50 | 01-OCT-10:52 | 0.91 |
| November | 83739317.70 | 0.61 | 275.50 | 01-NOV-07:42 | 0.90 |
| December | 52250124.08 | 0.51 | 275.50 | 01-DEC-14:42 | 0.91 |
| Annual Sum or Average | 0.162006E+10 | 0.69 | |||
| Minimum of Months | 22711991.05 | 0.29 | 275.50 | 0.90 | |
| Maximum of Months | 0.247175E+09 | 0.99 | 275.50 | 0.91 |
Report: FanReportMonthly
For: G N1 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: G N1 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: SPLIT GN2 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 22653546.49 | 0.29 | 275.06 | 01-JAN-12:42 | 0.91 |
| February | 26835170.57 | 0.31 | 275.06 | 01-FEB-14:12 | 0.91 |
| March | 41648095.87 | 0.42 | 275.06 | 01-MAR-19:42 | 0.91 |
| April | 83649484.28 | 0.60 | 275.06 | 01-APR-11:52 | 0.91 |
| May | 0.200078E+09 | 0.95 | 275.06 | 02-MAY-07:52 | 0.90 |
| June | 0.214999E+09 | 0.98 | 275.06 | 01-JUN-07:32 | 0.90 |
| July | 0.245647E+09 | 0.99 | 275.06 | 11-JUL-21:22 | 0.90 |
| August | 0.247165E+09 | 0.96 | 275.06 | 01-AUG-06:52 | 0.90 |
| September | 0.217978E+09 | 0.89 | 275.06 | 01-SEP-07:02 | 0.90 |
| October | 0.183812E+09 | 0.80 | 275.06 | 01-OCT-10:52 | 0.91 |
| November | 83734329.18 | 0.61 | 275.06 | 01-NOV-07:42 | 0.90 |
| December | 51973663.43 | 0.51 | 275.06 | 01-DEC-14:42 | 0.91 |
| Annual Sum or Average | 0.162017E+10 | 0.69 | |||
| Minimum of Months | 22653546.49 | 0.29 | 275.06 | 0.90 | |
| Maximum of Months | 0.247165E+09 | 0.99 | 275.06 | 0.91 |
Report: FanReportMonthly
For: G N2 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: G N2 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: SPLIT GS1 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 84550305.43 | 0.74 | 298.23 | 01-JAN-10:52 | 0.91 |
| February | 72840881.48 | 0.61 | 298.23 | 01-FEB-13:22 | 0.91 |
| March | 69748222.35 | 0.54 | 298.23 | 01-MAR-07:53 | 0.91 |
| April | 0.101638E+09 | 0.61 | 298.23 | 01-APR-11:22 | 0.90 |
| May | 0.203411E+09 | 0.95 | 298.23 | 02-MAY-07:52 | 0.90 |
| June | 0.211931E+09 | 0.98 | 298.23 | 01-JUN-07:32 | 0.90 |
| July | 0.246521E+09 | 0.99 | 298.23 | 11-JUL-21:22 | 0.90 |
| August | 0.258799E+09 | 0.96 | 298.23 | 01-AUG-06:52 | 0.90 |
| September | 0.242810E+09 | 0.89 | 298.23 | 01-SEP-07:02 | 0.91 |
| October | 0.232784E+09 | 0.82 | 298.23 | 01-OCT-09:52 | 0.91 |
| November | 0.144746E+09 | 0.68 | 298.23 | 01-NOV-07:32 | 0.90 |
| December | 0.115258E+09 | 0.72 | 298.23 | 01-DEC-11:32 | 0.91 |
| Annual Sum or Average | 0.198504E+10 | 0.79 | |||
| Minimum of Months | 69748222.35 | 0.54 | 298.23 | 0.90 | |
| Maximum of Months | 0.258799E+09 | 0.99 | 298.23 | 0.91 |
Report: FanReportMonthly
For: G S1 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: G S1 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: SPLIT GS2 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 86348965.35 | 0.73 | 301.43 | 01-JAN-10:52 | 0.91 |
| February | 73496530.51 | 0.61 | 301.43 | 01-FEB-13:22 | 0.91 |
| March | 72426341.75 | 0.54 | 301.43 | 01-MAR-07:53 | 0.91 |
| April | 0.107079E+09 | 0.62 | 301.43 | 01-APR-11:22 | 0.90 |
| May | 0.219633E+09 | 0.95 | 301.43 | 02-MAY-07:52 | 0.90 |
| June | 0.228990E+09 | 0.98 | 301.43 | 01-JUN-07:32 | 0.90 |
| July | 0.266896E+09 | 0.99 | 301.43 | 11-JUL-21:22 | 0.90 |
| August | 0.277748E+09 | 0.96 | 301.43 | 01-AUG-06:52 | 0.90 |
| September | 0.259840E+09 | 0.89 | 301.43 | 01-SEP-07:02 | 0.91 |
| October | 0.248118E+09 | 0.82 | 301.43 | 01-OCT-09:52 | 0.91 |
| November | 0.151517E+09 | 0.68 | 301.43 | 01-NOV-07:32 | 0.90 |
| December | 0.119014E+09 | 0.71 | 301.43 | 01-DEC-11:32 | 0.91 |
| Annual Sum or Average | 0.211111E+10 | 0.79 | |||
| Minimum of Months | 72426341.75 | 0.54 | 301.43 | 0.90 | |
| Maximum of Months | 0.277748E+09 | 0.99 | 301.43 | 0.91 |
Report: FanReportMonthly
For: G S2 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: G S2 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: SPLIT MSW SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.175551E+09 | 0.56 | 789.70 | 01-JAN-10:52 | 0.91 |
| February | 0.194519E+09 | 0.56 | 789.70 | 01-FEB-13:22 | 0.91 |
| March | 0.213056E+09 | 0.57 | 789.70 | 01-MAR-19:42 | 0.91 |
| April | 0.322826E+09 | 0.65 | 789.70 | 01-APR-11:22 | 0.91 |
| May | 0.560371E+09 | 0.95 | 789.70 | 02-MAY-07:52 | 0.90 |
| June | 0.571808E+09 | 0.98 | 789.70 | 01-JUN-07:32 | 0.90 |
| July | 0.620691E+09 | 0.99 | 789.70 | 11-JUL-21:22 | 0.90 |
| August | 0.614065E+09 | 0.96 | 789.70 | 01-AUG-06:52 | 0.90 |
| September | 0.560681E+09 | 0.89 | 789.70 | 01-SEP-07:02 | 0.90 |
| October | 0.530468E+09 | 0.83 | 789.70 | 01-OCT-09:52 | 0.91 |
| November | 0.304090E+09 | 0.69 | 789.70 | 01-NOV-07:32 | 0.90 |
| December | 0.231647E+09 | 0.62 | 789.70 | 01-DEC-11:32 | 0.91 |
| Annual Sum or Average | 0.489977E+10 | 0.77 | |||
| Minimum of Months | 0.175551E+09 | 0.56 | 789.70 | 0.90 | |
| Maximum of Months | 0.620691E+09 | 0.99 | 789.70 | 0.91 |
Report: FanReportMonthly
For: M SW APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.73 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.73 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.73 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.73 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.73 | 46.34 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.73 | 46.34 | 0.73 |
Report: FanReportMonthly
For: M SW APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.73 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.73 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.73 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.73 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.73 | 46.34 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.73 | 46.34 | 0.73 |
Report: FanReportMonthly
For: SPLIT MNW SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 57960658.72 | 0.22 | 752.18 | 01-JAN-12:42 | 0.91 |
| February | 95964035.10 | 0.35 | 752.18 | 01-FEB-14:12 | 0.91 |
| March | 0.150708E+09 | 0.46 | 752.18 | 01-MAR-19:42 | 0.91 |
| April | 0.282920E+09 | 0.63 | 752.18 | 01-APR-11:52 | 0.91 |
| May | 0.553395E+09 | 0.95 | 752.18 | 02-MAY-07:52 | 0.90 |
| June | 0.578144E+09 | 0.98 | 752.18 | 01-JUN-07:32 | 0.90 |
| July | 0.618830E+09 | 0.99 | 752.18 | 11-JUL-21:22 | 0.90 |
| August | 0.589405E+09 | 0.96 | 752.18 | 01-AUG-06:52 | 0.90 |
| September | 0.507662E+09 | 0.89 | 752.18 | 01-SEP-07:02 | 0.90 |
| October | 0.422538E+09 | 0.80 | 752.18 | 01-OCT-10:52 | 0.91 |
| November | 0.171678E+09 | 0.56 | 752.18 | 01-NOV-07:42 | 0.90 |
| December | 0.107351E+09 | 0.34 | 752.18 | 01-DEC-14:42 | 0.91 |
| Annual Sum or Average | 0.413656E+10 | 0.68 | |||
| Minimum of Months | 57960658.72 | 0.22 | 752.18 | 0.90 | |
| Maximum of Months | 0.618830E+09 | 0.99 | 752.18 | 0.91 |
Report: FanReportMonthly
For: M NW APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.73 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.73 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.73 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.73 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.73 | 46.34 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.73 | 46.34 | 0.73 |
Report: FanReportMonthly
For: M NW APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.73 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.73 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.73 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.73 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.73 | 46.34 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.73 | 46.34 | 0.73 |
Report: FanReportMonthly
For: SPLIT MSE SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.169935E+09 | 0.57 | 724.62 | 01-JAN-10:52 | 0.91 |
| February | 0.186232E+09 | 0.56 | 724.62 | 01-FEB-13:22 | 0.91 |
| March | 0.211836E+09 | 0.56 | 724.62 | 01-MAR-19:42 | 0.91 |
| April | 0.314441E+09 | 0.65 | 724.62 | 01-APR-11:22 | 0.90 |
| May | 0.560729E+09 | 0.95 | 724.62 | 02-MAY-07:52 | 0.90 |
| June | 0.568096E+09 | 0.98 | 724.62 | 01-JUN-07:32 | 0.90 |
| July | 0.620720E+09 | 0.99 | 724.62 | 11-JUL-21:22 | 0.90 |
| August | 0.604446E+09 | 0.96 | 724.62 | 01-AUG-06:52 | 0.90 |
| September | 0.549183E+09 | 0.89 | 724.62 | 01-SEP-07:02 | 0.90 |
| October | 0.516393E+09 | 0.82 | 724.62 | 01-OCT-09:52 | 0.91 |
| November | 0.297082E+09 | 0.68 | 724.62 | 01-NOV-07:32 | 0.90 |
| December | 0.218621E+09 | 0.61 | 724.62 | 01-DEC-11:32 | 0.91 |
| Annual Sum or Average | 0.481771E+10 | 0.77 | |||
| Minimum of Months | 0.169935E+09 | 0.56 | 724.62 | 0.90 | |
| Maximum of Months | 0.620720E+09 | 0.99 | 724.62 | 0.91 |
Report: FanReportMonthly
For: M SE APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.73 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.73 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.73 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.73 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.73 | 46.34 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.73 | 46.34 | 0.73 |
Report: FanReportMonthly
For: M SE APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.73 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.73 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.73 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.73 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.73 | 46.34 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.73 | 46.34 | 0.73 |
Report: FanReportMonthly
For: SPLIT MNE SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 52869994.29 | 0.20 | 687.79 | 01-JAN-12:42 | 0.91 |
| February | 88352891.22 | 0.36 | 687.79 | 01-FEB-14:12 | 0.91 |
| March | 0.149199E+09 | 0.47 | 687.79 | 01-MAR-19:42 | 0.91 |
| April | 0.276253E+09 | 0.63 | 687.79 | 01-APR-11:52 | 0.91 |
| May | 0.553906E+09 | 0.95 | 687.79 | 02-MAY-07:52 | 0.90 |
| June | 0.574194E+09 | 0.98 | 687.79 | 01-JUN-07:32 | 0.90 |
| July | 0.618817E+09 | 0.99 | 687.79 | 11-JUL-21:22 | 0.90 |
| August | 0.580443E+09 | 0.96 | 687.79 | 01-AUG-06:52 | 0.90 |
| September | 0.497626E+09 | 0.89 | 687.79 | 01-SEP-07:02 | 0.90 |
| October | 0.410995E+09 | 0.80 | 687.79 | 01-OCT-10:52 | 0.91 |
| November | 0.166813E+09 | 0.56 | 687.79 | 01-NOV-07:42 | 0.90 |
| December | 97957063.60 | 0.34 | 687.79 | 01-DEC-14:42 | 0.91 |
| Annual Sum or Average | 0.406743E+10 | 0.68 | |||
| Minimum of Months | 52869994.29 | 0.20 | 687.79 | 0.90 | |
| Maximum of Months | 0.618817E+09 | 0.99 | 687.79 | 0.91 |
Report: FanReportMonthly
For: M NE APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.73 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.73 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.73 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.73 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.73 | 46.34 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.73 | 46.34 | 0.73 |
Report: FanReportMonthly
For: M NE APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.73 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.73 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.73 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.73 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.73 | 46.34 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.73 | 46.34 | 0.73 |
Report: FanReportMonthly
For: SPLIT MN1 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62348675.21 | 0.35 | 612.01 | 01-JAN-12:42 | 0.91 |
| February | 94953786.99 | 0.44 | 612.01 | 01-FEB-14:12 | 0.91 |
| March | 0.143524E+09 | 0.55 | 612.01 | 01-MAR-19:42 | 0.91 |
| April | 0.238775E+09 | 0.62 | 612.01 | 01-APR-11:52 | 0.91 |
| May | 0.454701E+09 | 0.95 | 612.01 | 02-MAY-07:52 | 0.90 |
| June | 0.470061E+09 | 0.98 | 612.01 | 01-JUN-07:32 | 0.90 |
| July | 0.508201E+09 | 0.99 | 612.01 | 11-JUL-21:22 | 0.90 |
| August | 0.480772E+09 | 0.96 | 612.01 | 01-AUG-06:52 | 0.90 |
| September | 0.420859E+09 | 0.89 | 612.01 | 01-SEP-07:02 | 0.90 |
| October | 0.351215E+09 | 0.79 | 612.01 | 01-OCT-10:52 | 0.91 |
| November | 0.165370E+09 | 0.60 | 612.01 | 01-NOV-07:42 | 0.90 |
| December | 0.109836E+09 | 0.50 | 612.01 | 01-DEC-14:42 | 0.91 |
| Annual Sum or Average | 0.350062E+10 | 0.72 | |||
| Minimum of Months | 62348675.21 | 0.35 | 612.01 | 0.90 | |
| Maximum of Months | 0.508201E+09 | 0.99 | 612.01 | 0.91 |
Report: FanReportMonthly
For: M N1 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.73 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.73 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.73 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.73 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.73 | 46.34 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.73 | 46.34 | 0.73 |
Report: FanReportMonthly
For: M N1 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.73 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.73 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.73 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.73 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.73 | 46.34 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.73 | 46.34 | 0.73 |
Report: FanReportMonthly
For: SPLIT MN2 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62254553.49 | 0.35 | 610.87 | 01-JAN-12:42 | 0.91 |
| February | 94741612.48 | 0.44 | 610.87 | 01-FEB-14:12 | 0.91 |
| March | 0.143816E+09 | 0.55 | 610.87 | 01-MAR-19:42 | 0.91 |
| April | 0.239173E+09 | 0.62 | 610.87 | 01-APR-11:52 | 0.91 |
| May | 0.455038E+09 | 0.95 | 610.87 | 02-MAY-07:52 | 0.90 |
| June | 0.470239E+09 | 0.98 | 610.87 | 01-JUN-07:32 | 0.90 |
| July | 0.508492E+09 | 0.99 | 610.87 | 11-JUL-21:22 | 0.90 |
| August | 0.480745E+09 | 0.96 | 610.87 | 01-AUG-06:52 | 0.90 |
| September | 0.420762E+09 | 0.89 | 610.87 | 01-SEP-07:02 | 0.90 |
| October | 0.351071E+09 | 0.79 | 610.87 | 01-OCT-10:52 | 0.91 |
| November | 0.165350E+09 | 0.60 | 610.87 | 01-NOV-07:42 | 0.90 |
| December | 0.109216E+09 | 0.50 | 610.87 | 01-DEC-14:42 | 0.91 |
| Annual Sum or Average | 0.350090E+10 | 0.72 | |||
| Minimum of Months | 62254553.49 | 0.35 | 610.87 | 0.90 | |
| Maximum of Months | 0.508492E+09 | 0.99 | 610.87 | 0.91 |
Report: FanReportMonthly
For: M N2 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.73 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.73 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.73 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.73 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.73 | 46.34 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.73 | 46.34 | 0.73 |
Report: FanReportMonthly
For: M N2 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.73 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.73 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.73 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.73 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.73 | 46.34 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.73 | 46.34 | 0.73 |
Report: FanReportMonthly
For: SPLIT MS1 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.204842E+09 | 0.73 | 652.39 | 01-JAN-10:52 | 0.91 |
| February | 0.203477E+09 | 0.66 | 652.39 | 01-FEB-13:22 | 0.91 |
| March | 0.209362E+09 | 0.64 | 652.39 | 01-MAR-07:53 | 0.91 |
| April | 0.278619E+09 | 0.65 | 652.39 | 01-APR-11:22 | 0.90 |
| May | 0.461976E+09 | 0.95 | 652.39 | 02-MAY-07:52 | 0.90 |
| June | 0.464167E+09 | 0.98 | 652.39 | 01-JUN-07:32 | 0.90 |
| July | 0.510518E+09 | 0.99 | 652.39 | 11-JUL-21:22 | 0.90 |
| August | 0.505421E+09 | 0.96 | 652.39 | 01-AUG-06:52 | 0.90 |
| September | 0.473527E+09 | 0.89 | 652.39 | 01-SEP-07:02 | 0.90 |
| October | 0.457015E+09 | 0.83 | 652.39 | 01-OCT-09:52 | 0.91 |
| November | 0.297588E+09 | 0.70 | 652.39 | 01-NOV-07:32 | 0.90 |
| December | 0.247450E+09 | 0.71 | 652.39 | 01-DEC-11:32 | 0.91 |
| Annual Sum or Average | 0.431396E+10 | 0.81 | |||
| Minimum of Months | 0.203477E+09 | 0.64 | 652.39 | 0.90 | |
| Maximum of Months | 0.510518E+09 | 0.99 | 652.39 | 0.91 |
Report: FanReportMonthly
For: M S1 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.73 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.73 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.73 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.73 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.73 | 46.34 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.73 | 46.34 | 0.73 |
Report: FanReportMonthly
For: M S1 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.73 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.73 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.73 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.73 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.73 | 46.34 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.73 | 46.34 | 0.73 |
Report: FanReportMonthly
For: SPLIT MS2 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.204872E+09 | 0.73 | 651.34 | 01-JAN-10:52 | 0.91 |
| February | 0.203351E+09 | 0.66 | 651.34 | 01-FEB-13:22 | 0.91 |
| March | 0.209736E+09 | 0.64 | 651.34 | 01-MAR-07:53 | 0.91 |
| April | 0.278973E+09 | 0.65 | 651.34 | 01-APR-11:22 | 0.90 |
| May | 0.462324E+09 | 0.95 | 651.34 | 02-MAY-07:52 | 0.90 |
| June | 0.464368E+09 | 0.98 | 651.34 | 01-JUN-07:32 | 0.90 |
| July | 0.510827E+09 | 0.99 | 651.34 | 11-JUL-21:22 | 0.90 |
| August | 0.505384E+09 | 0.96 | 651.34 | 01-AUG-06:52 | 0.90 |
| September | 0.473394E+09 | 0.89 | 651.34 | 01-SEP-07:02 | 0.90 |
| October | 0.456857E+09 | 0.83 | 651.34 | 01-OCT-09:52 | 0.91 |
| November | 0.297647E+09 | 0.70 | 651.34 | 01-NOV-07:32 | 0.90 |
| December | 0.246901E+09 | 0.71 | 651.34 | 01-DEC-11:32 | 0.91 |
| Annual Sum or Average | 0.431463E+10 | 0.81 | |||
| Minimum of Months | 0.203351E+09 | 0.64 | 651.34 | 0.90 | |
| Maximum of Months | 0.510827E+09 | 0.99 | 651.34 | 0.91 |
Report: FanReportMonthly
For: M S2 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.73 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.73 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.73 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.73 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.73 | 46.34 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.73 | 46.34 | 0.73 |
Report: FanReportMonthly
For: M S2 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.73 | 46.34 | 01-JAN-00:10 | 0.72 |
| February | 0.112112E+09 | 0.73 | 46.34 | 01-FEB-00:10 | 0.72 |
| March | 0.124124E+09 | 0.73 | 46.34 | 01-MAR-00:10 | 0.72 |
| April | 0.120120E+09 | 0.72 | 46.34 | 01-APR-00:10 | 0.72 |
| May | 0.124124E+09 | 0.72 | 46.34 | 01-MAY-00:10 | 0.72 |
| June | 0.120120E+09 | 0.72 | 46.34 | 01-JUN-00:10 | 0.72 |
| July | 0.124124E+09 | 0.72 | 46.34 | 01-JUL-00:10 | 0.72 |
| August | 0.124124E+09 | 0.72 | 46.34 | 01-AUG-00:10 | 0.72 |
| September | 0.120120E+09 | 0.72 | 46.34 | 01-SEP-00:10 | 0.72 |
| October | 0.124124E+09 | 0.72 | 46.34 | 01-OCT-00:10 | 0.72 |
| November | 0.120120E+09 | 0.73 | 46.34 | 01-NOV-00:10 | 0.72 |
| December | 0.124124E+09 | 0.73 | 46.34 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.146145E+10 | 0.72 | |||
| Minimum of Months | 0.112112E+09 | 0.72 | 46.34 | 0.72 | |
| Maximum of Months | 0.124124E+09 | 0.73 | 46.34 | 0.73 |
Report: FanReportMonthly
For: SPLIT TSW SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 69553438.90 | 0.45 | 439.21 | 01-JAN-10:52 | 0.91 |
| February | 81085872.43 | 0.44 | 439.21 | 01-FEB-13:22 | 0.91 |
| March | 93125842.87 | 0.47 | 439.21 | 02-MAR-19:02 | 0.91 |
| April | 0.154495E+09 | 0.58 | 439.21 | 01-APR-11:22 | 0.91 |
| May | 0.309394E+09 | 0.95 | 439.21 | 02-MAY-07:52 | 0.90 |
| June | 0.321203E+09 | 0.98 | 439.21 | 01-JUN-07:32 | 0.90 |
| July | 0.347150E+09 | 0.99 | 439.21 | 11-JUL-21:22 | 0.90 |
| August | 0.341555E+09 | 0.96 | 439.21 | 01-AUG-06:52 | 0.90 |
| September | 0.301276E+09 | 0.89 | 439.21 | 01-SEP-07:02 | 0.90 |
| October | 0.276902E+09 | 0.79 | 439.21 | 01-OCT-09:52 | 0.91 |
| November | 0.124606E+09 | 0.50 | 439.21 | 01-NOV-07:32 | 0.90 |
| December | 95619049.52 | 0.45 | 439.21 | 01-DEC-11:32 | 0.91 |
| Annual Sum or Average | 0.251596E+10 | 0.71 | |||
| Minimum of Months | 69553438.90 | 0.44 | 439.21 | 0.90 | |
| Maximum of Months | 0.347150E+09 | 0.99 | 439.21 | 0.91 |
Report: FanReportMonthly
For: T SW APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: T SW APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: SPLIT TNW SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 49631363.95 | 0.45 | 425.15 | 01-JAN-12:42 | 0.91 |
| February | 51839500.15 | 0.40 | 425.15 | 01-FEB-14:12 | 0.91 |
| March | 70047281.43 | 0.43 | 425.15 | 02-MAR-19:02 | 0.91 |
| April | 0.134642E+09 | 0.56 | 425.15 | 01-APR-11:52 | 0.91 |
| May | 0.306776E+09 | 0.95 | 425.15 | 02-MAY-07:52 | 0.90 |
| June | 0.325355E+09 | 0.98 | 425.15 | 01-JUN-07:32 | 0.90 |
| July | 0.347256E+09 | 0.99 | 425.15 | 11-JUL-21:22 | 0.91 |
| August | 0.329244E+09 | 0.96 | 425.15 | 01-AUG-06:52 | 0.90 |
| September | 0.274246E+09 | 0.89 | 425.15 | 01-SEP-07:02 | 0.90 |
| October | 0.222028E+09 | 0.75 | 425.15 | 01-OCT-10:52 | 0.91 |
| November | 67064266.06 | 0.36 | 425.15 | 01-NOV-07:42 | 0.90 |
| December | 58974998.75 | 0.42 | 425.15 | 01-DEC-14:42 | 0.91 |
| Annual Sum or Average | 0.223710E+10 | 0.68 | |||
| Minimum of Months | 49631363.95 | 0.36 | 425.15 | 0.90 | |
| Maximum of Months | 0.347256E+09 | 0.99 | 425.15 | 0.91 |
Report: FanReportMonthly
For: T NW APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: T NW APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: SPLIT TSE SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 64203533.59 | 0.45 | 390.75 | 01-JAN-10:52 | 0.91 |
| February | 75777371.29 | 0.44 | 390.75 | 01-FEB-13:22 | 0.91 |
| March | 90952251.64 | 0.45 | 390.75 | 02-MAR-19:02 | 0.91 |
| April | 0.148370E+09 | 0.58 | 390.75 | 01-APR-11:02 | 0.90 |
| May | 0.308133E+09 | 0.95 | 390.75 | 02-MAY-07:52 | 0.90 |
| June | 0.317737E+09 | 0.98 | 390.75 | 01-JUN-07:32 | 0.90 |
| July | 0.345637E+09 | 0.99 | 390.75 | 11-JUL-21:22 | 0.90 |
| August | 0.334773E+09 | 0.96 | 390.75 | 01-AUG-06:52 | 0.90 |
| September | 0.294098E+09 | 0.89 | 390.75 | 01-SEP-07:02 | 0.90 |
| October | 0.268169E+09 | 0.78 | 390.75 | 01-OCT-09:52 | 0.91 |
| November | 0.120397E+09 | 0.50 | 390.75 | 01-NOV-07:32 | 0.90 |
| December | 89086959.08 | 0.44 | 390.75 | 01-DEC-11:32 | 0.91 |
| Annual Sum or Average | 0.245733E+10 | 0.70 | |||
| Minimum of Months | 64203533.59 | 0.44 | 390.75 | 0.90 | |
| Maximum of Months | 0.345637E+09 | 0.99 | 390.75 | 0.91 |
Report: FanReportMonthly
For: T SE APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: T SE APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: SPLIT TNE SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 45652802.85 | 0.43 | 376.73 | 01-JAN-12:42 | 0.91 |
| February | 46875868.30 | 0.38 | 376.73 | 01-FEB-14:12 | 0.91 |
| March | 69009651.82 | 0.43 | 376.73 | 04-MAR-12:22 | 0.91 |
| April | 0.129115E+09 | 0.56 | 376.73 | 01-APR-11:52 | 0.91 |
| May | 0.305298E+09 | 0.95 | 376.73 | 02-MAY-07:52 | 0.90 |
| June | 0.321406E+09 | 0.98 | 376.73 | 01-JUN-07:32 | 0.90 |
| July | 0.345388E+09 | 0.99 | 376.73 | 11-JUL-21:22 | 0.90 |
| August | 0.322582E+09 | 0.96 | 376.73 | 01-AUG-06:52 | 0.90 |
| September | 0.267725E+09 | 0.89 | 376.73 | 01-SEP-07:02 | 0.90 |
| October | 0.214661E+09 | 0.74 | 376.73 | 01-OCT-10:52 | 0.91 |
| November | 63842178.51 | 0.35 | 376.73 | 01-NOV-07:42 | 0.90 |
| December | 54868518.33 | 0.42 | 376.73 | 01-DEC-14:42 | 0.91 |
| Annual Sum or Average | 0.218642E+10 | 0.67 | |||
| Minimum of Months | 45652802.85 | 0.35 | 376.73 | 0.90 | |
| Maximum of Months | 0.345388E+09 | 0.99 | 376.73 | 0.91 |
Report: FanReportMonthly
For: T NE APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: T NE APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: SPLIT TN1 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 32901556.48 | 0.38 | 349.81 | 01-JAN-12:42 | 0.91 |
| February | 39572895.79 | 0.37 | 349.81 | 01-FEB-14:12 | 0.91 |
| March | 58026472.33 | 0.41 | 349.81 | 04-MAR-12:22 | 0.91 |
| April | 0.113553E+09 | 0.58 | 349.81 | 01-APR-11:52 | 0.91 |
| May | 0.257802E+09 | 0.95 | 349.81 | 02-MAY-07:52 | 0.90 |
| June | 0.271507E+09 | 0.98 | 349.81 | 01-JUN-07:32 | 0.90 |
| July | 0.292473E+09 | 0.99 | 349.81 | 11-JUL-21:22 | 0.90 |
| August | 0.274815E+09 | 0.96 | 349.81 | 01-AUG-06:52 | 0.90 |
| September | 0.231778E+09 | 0.89 | 349.81 | 01-SEP-07:02 | 0.90 |
| October | 0.185991E+09 | 0.77 | 349.81 | 01-OCT-10:52 | 0.91 |
| November | 59590461.42 | 0.38 | 349.81 | 01-NOV-07:42 | 0.90 |
| December | 44470164.31 | 0.35 | 349.81 | 01-DEC-14:42 | 0.91 |
| Annual Sum or Average | 0.186248E+10 | 0.67 | |||
| Minimum of Months | 32901556.48 | 0.35 | 349.81 | 0.90 | |
| Maximum of Months | 0.292473E+09 | 0.99 | 349.81 | 0.91 |
Report: FanReportMonthly
For: T N1 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: T N1 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: SPLIT TN2 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 32841455.37 | 0.38 | 348.25 | 01-JAN-12:42 | 0.91 |
| February | 39445381.29 | 0.37 | 348.25 | 01-FEB-14:12 | 0.91 |
| March | 58188475.23 | 0.42 | 348.25 | 04-MAR-12:22 | 0.91 |
| April | 0.113613E+09 | 0.58 | 348.25 | 01-APR-11:52 | 0.91 |
| May | 0.257881E+09 | 0.95 | 348.25 | 02-MAY-07:52 | 0.90 |
| June | 0.271477E+09 | 0.98 | 348.25 | 01-JUN-07:32 | 0.90 |
| July | 0.292492E+09 | 0.99 | 348.25 | 11-JUL-21:22 | 0.90 |
| August | 0.274653E+09 | 0.96 | 348.25 | 01-AUG-06:52 | 0.90 |
| September | 0.231617E+09 | 0.89 | 348.25 | 01-SEP-07:02 | 0.90 |
| October | 0.185805E+09 | 0.76 | 348.25 | 01-OCT-10:52 | 0.91 |
| November | 59583838.06 | 0.37 | 348.25 | 01-NOV-07:42 | 0.90 |
| December | 44367918.75 | 0.36 | 348.25 | 01-DEC-14:42 | 0.91 |
| Annual Sum or Average | 0.186197E+10 | 0.67 | |||
| Minimum of Months | 32841455.37 | 0.36 | 348.25 | 0.90 | |
| Maximum of Months | 0.292492E+09 | 0.99 | 348.25 | 0.91 |
Report: FanReportMonthly
For: T N2 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: T N2 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: SPLIT TS1 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 60953996.36 | 0.41 | 365.09 | 01-JAN-10:52 | 0.91 |
| February | 72923588.68 | 0.47 | 365.09 | 01-FEB-13:22 | 0.91 |
| March | 82329667.38 | 0.48 | 365.09 | 02-MAR-19:02 | 0.91 |
| April | 0.133142E+09 | 0.61 | 365.09 | 01-APR-11:22 | 0.91 |
| May | 0.260543E+09 | 0.95 | 365.09 | 02-MAY-07:52 | 0.90 |
| June | 0.267505E+09 | 0.98 | 365.09 | 01-JUN-07:32 | 0.90 |
| July | 0.292526E+09 | 0.99 | 365.09 | 11-JUL-21:22 | 0.90 |
| August | 0.287218E+09 | 0.96 | 365.09 | 01-AUG-06:52 | 0.90 |
| September | 0.258786E+09 | 0.89 | 365.09 | 01-SEP-07:02 | 0.90 |
| October | 0.240781E+09 | 0.81 | 365.09 | 01-OCT-09:52 | 0.91 |
| November | 0.119944E+09 | 0.57 | 365.09 | 01-NOV-07:32 | 0.90 |
| December | 88135157.64 | 0.46 | 365.09 | 01-DEC-11:32 | 0.91 |
| Annual Sum or Average | 0.216479E+10 | 0.72 | |||
| Minimum of Months | 60953996.36 | 0.41 | 365.09 | 0.90 | |
| Maximum of Months | 0.292526E+09 | 0.99 | 365.09 | 0.91 |
Report: FanReportMonthly
For: T S1 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: T S1 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: SPLIT TS2 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 61093210.69 | 0.41 | 363.53 | 01-JAN-10:52 | 0.91 |
| February | 72900868.91 | 0.46 | 363.53 | 01-FEB-13:22 | 0.91 |
| March | 82610470.31 | 0.48 | 363.53 | 02-MAR-19:02 | 0.91 |
| April | 0.133216E+09 | 0.61 | 363.53 | 01-APR-11:22 | 0.91 |
| May | 0.260634E+09 | 0.95 | 363.53 | 02-MAY-07:52 | 0.90 |
| June | 0.267501E+09 | 0.98 | 363.53 | 01-JUN-07:32 | 0.90 |
| July | 0.292562E+09 | 0.99 | 363.53 | 11-JUL-21:22 | 0.90 |
| August | 0.287049E+09 | 0.96 | 363.53 | 01-AUG-06:52 | 0.90 |
| September | 0.258593E+09 | 0.89 | 363.53 | 01-SEP-07:02 | 0.90 |
| October | 0.240571E+09 | 0.81 | 363.53 | 01-OCT-09:52 | 0.91 |
| November | 0.119980E+09 | 0.57 | 363.53 | 01-NOV-07:32 | 0.90 |
| December | 87952586.17 | 0.46 | 363.53 | 01-DEC-11:32 | 0.91 |
| Annual Sum or Average | 0.216466E+10 | 0.72 | |||
| Minimum of Months | 61093210.69 | 0.41 | 363.53 | 0.90 | |
| Maximum of Months | 0.292562E+09 | 0.99 | 363.53 | 0.91 |
Report: FanReportMonthly
For: T S2 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: FanReportMonthly
For: T S2 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.73 | 23.17 | 01-JAN-00:10 | 0.72 |
| February | 56055778.84 | 0.73 | 23.17 | 01-FEB-00:10 | 0.72 |
| March | 62061755.14 | 0.73 | 23.17 | 01-MAR-00:10 | 0.72 |
| April | 60059763.04 | 0.72 | 23.17 | 01-APR-00:10 | 0.72 |
| May | 62061755.14 | 0.72 | 23.17 | 01-MAY-00:10 | 0.72 |
| June | 60059763.04 | 0.72 | 23.17 | 01-JUN-00:10 | 0.72 |
| July | 62061755.14 | 0.72 | 23.17 | 01-JUL-00:10 | 0.72 |
| August | 62061755.14 | 0.72 | 23.17 | 01-AUG-00:10 | 0.72 |
| September | 60059763.04 | 0.72 | 23.17 | 01-SEP-00:10 | 0.72 |
| October | 62061755.14 | 0.72 | 23.17 | 01-OCT-00:10 | 0.72 |
| November | 60059763.04 | 0.73 | 23.17 | 01-NOV-00:10 | 0.72 |
| December | 62061755.14 | 0.73 | 23.17 | 01-DEC-00:10 | 0.73 |
| Annual Sum or Average | 0.730727E+09 | 0.72 | |||
| Minimum of Months | 56055778.84 | 0.72 | 23.17 | 0.72 | |
| Maximum of Months | 62061755.14 | 0.73 | 23.17 | 0.73 |
Report: PumpReportMonthly
For: SWHSYS1 PUMP
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
| January | 38818862.27 | 11645658.68 | 14.49 | 01-JAN-00:10 | 4.35 | 4.35 | 56.00 | 0.11 |
| February | 35062198.18 | 10518659.46 | 14.49 | 01-FEB-00:10 | 4.35 | 4.35 | 55.97 | 0.11 |
| March | 38818862.27 | 11645658.68 | 14.49 | 01-MAR-00:10 | 4.35 | 4.35 | 56.06 | 0.11 |
| April | 37566640.91 | 11269992.27 | 14.49 | 01-APR-00:10 | 4.35 | 4.35 | 58.35 | 0.11 |
| May | 38818862.27 | 11645658.68 | 14.49 | 01-MAY-00:10 | 4.35 | 4.35 | 58.45 | 0.11 |
| June | 37566640.91 | 11269992.27 | 14.49 | 01-JUN-00:10 | 4.35 | 4.35 | 58.56 | 0.11 |
| July | 38818862.27 | 11645658.68 | 14.49 | 01-JUL-00:10 | 4.35 | 4.35 | 58.62 | 0.11 |
| August | 38818862.27 | 11645658.68 | 14.49 | 01-AUG-00:10 | 4.35 | 4.35 | 58.64 | 0.11 |
| September | 37566640.91 | 11269992.27 | 14.49 | 01-SEP-00:10 | 4.35 | 4.35 | 58.60 | 0.11 |
| October | 38818862.27 | 11645658.68 | 14.49 | 01-OCT-00:10 | 4.35 | 4.35 | 58.51 | 0.11 |
| November | 37566640.91 | 11269992.27 | 14.49 | 01-NOV-00:10 | 4.35 | 4.35 | 58.40 | 0.11 |
| December | 38818862.27 | 11645658.68 | 14.49 | 01-DEC-00:10 | 4.35 | 4.35 | 56.15 | 0.11 |
| Annual Sum or Average | 0.457061E+09 | 0.137118E+09 | ||||||
| Minimum of Months | 35062198.18 | 10518659.46 | 14.49 | 4.35 | 4.35 | 55.97 | 0.11 | |
| Maximum of Months | 38818862.27 | 11645658.68 | 14.49 | 4.35 | 4.35 | 58.64 | 0.11 |
Report: CondLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 56.00 | 59.95 | 9837.00 | 18792.91 | 23-JAN-07:40 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 55.97 | 59.95 | 9757.04 | 18763.47 | 01-FEB-07:50 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 56.06 | 59.95 | 9396.68 | 18336.08 | 01-MAR-07:40 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 58.35 | 59.95 | 8833.40 | 17383.11 | 01-APR-06:50 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 58.45 | 59.94 | 8224.08 | 16226.56 | 01-MAY-06:50 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 58.56 | 59.95 | 7732.06 | 15114.50 | 01-JUN-06:50 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 58.62 | 59.95 | 7491.61 | 14402.98 | 01-JUL-06:50 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 58.64 | 59.95 | 7569.43 | 14688.22 | 31-AUG-06:50 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 58.60 | 59.95 | 7942.27 | 15605.64 | 30-SEP-06:50 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 58.51 | 59.95 | 8509.77 | 16796.57 | 31-OCT-06:50 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 58.40 | 59.95 | 9118.07 | 17879.55 | 30-NOV-07:50 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 56.15 | 59.95 | 9603.39 | 18619.05 | 31-DEC-07:50 |
| Annual Sum or Average | 0.00 | 8661.81 | ||||||
| Minimum of Months | 0.00 | 0.00 | 55.97 | 59.94 | 7491.61 | 14402.98 | ||
| Maximum of Months | 0.00 | 0.00 | 58.64 | 59.95 | 9837.00 | 18792.91 |
Report: ZoneTemperatureOscillationReportMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.335706E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.304232E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.304534E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.514564E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.114115E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.122699E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.143864E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.153186E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.139751E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.131075E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.715300E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.521807E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.107430E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.304232E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.153186E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.103925E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.127143E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.187951E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.432623E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.113219E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.125058E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.144343E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.148366E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.128406E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.107807E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.428887E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.250902E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.920343E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.103925E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.148366E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.130077E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.122086E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.133683E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.140802E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.183225E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.186210E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.195173E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.208444E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.189449E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.189838E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.153074E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.138920E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.197098E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.122086E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.208444E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 97122887.44 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.115037E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.191843E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.426750E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.115281E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.126118E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.146403E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.148095E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.127626E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.106518E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.424346E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.234788E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.919028E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 97122887.44 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.148095E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.111976E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.132464E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.204905E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.415898E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.101576E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.109907E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.126046E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.126302E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.110369E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.926752E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.413246E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.258404E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.820564E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.111976E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.126302E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.111715E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.132168E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.205515E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.416437E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.101701E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.109988E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.126166E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.126327E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.110364E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.926528E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.413316E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.257120E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.820826E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.111715E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.126327E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.412425E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.355069E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.341090E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.502696E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.102922E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.107929E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.126042E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.131635E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.122326E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.116520E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.707576E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.562748E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.995535E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.341090E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.131635E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.420605E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.357640E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.353618E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.528556E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.110838E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.116293E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.136077E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.140895E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.130588E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.123895E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.739257E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.580050E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.105656E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.353618E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.140895E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.820569E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.913444E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.100424E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.153795E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.273422E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.280735E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.306119E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.301670E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.272976E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.256763E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.143725E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.109189E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.237222E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.820569E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.306119E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.274416E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.454761E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.715266E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.135443E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.270992E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.284864E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.306291E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.290668E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.248134E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.205779E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.819582E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.512023E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.201978E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.274416E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.306291E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MSE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.804482E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.885797E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.101167E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.151739E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.277125E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.282544E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.310156E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.300844E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.270878E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.253239E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.142221E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.104382E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.236332E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.804482E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.310156E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.253741E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.424326E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.717788E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.133980E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.274780E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.286639E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.310355E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.290052E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.246451E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.202839E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.806759E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.473618E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.201272E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.253741E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.310355E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.302935E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.461319E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.698358E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.117278E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.228660E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.237977E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.258480E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.243586E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.211197E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.175533E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.808621E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.536226E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.175346E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.302935E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.258480E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.302537E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.460392E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.699944E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.117500E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.228884E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.238124E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.258690E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.243632E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.211200E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.175506E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.808719E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.533363E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.175403E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.302537E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.258690E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.982252E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.978983E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.101055E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.135997E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.231170E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.233828E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.258378E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.254749E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.236399E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.226708E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.144015E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.119392E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.213781E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.978983E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.258378E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.982617E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.978597E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.101259E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.136201E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.231400E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.233987E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.258597E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.254793E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.236391E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.226686E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.144078E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.119158E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.213867E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.978597E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.258597E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.334592E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.384051E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.440043E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.731609E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.149767E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.156381E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.169711E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.166383E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.145507E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.133120E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.585996E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.454701E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.121397E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.334592E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.169711E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.252004E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.251816E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.334910E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.639796E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.148765E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.158686E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.170067E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.160714E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.132736E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.107214E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.319022E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.289917E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.108693E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.251816E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.170067E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TSE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.313871E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.364175E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.436181E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.712871E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.151291E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.156928E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.171443E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.165462E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.144109E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.130808E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.574414E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.430358E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.120323E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.313871E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.171443E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.235740E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.231571E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.334881E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.622784E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.150230E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.159090E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.171700E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.159832E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.131527E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.105230E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.308388E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.274424E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.107839E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.231571E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.171700E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.169266E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.195527E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.280555E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.548749E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.127201E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.134804E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.145830E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.136543E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.114118E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.913574E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.287928E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.220226E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.920079E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.169266E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.145830E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.169099E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.195041E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.281499E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.549365E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.127316E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.134869E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.145927E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.136545E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.114108E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.913229E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.288075E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.219893E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.920385E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.169099E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.145927E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.293169E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.349570E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.393755E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.640721E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.128234E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.132482E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.145490E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.142311E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.127063E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.117638E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.572824E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.423141E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.106054E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.293169E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.145490E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.293976E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.349654E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.395346E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.641445E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.128353E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.132557E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.145593E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.142311E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.127042E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.117605E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.573316E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.422519E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.106109E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.293976E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.145593E+10 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 70924260.74 | 0.104689E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 64004363.11 | 0.963918E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 63751110.08 | 0.955556E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.106537E+09 | 0.159594E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.231329E+09 | 0.346091E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.247278E+09 | 0.369373E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.288896E+09 | 0.435770E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.309278E+09 | 0.466311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.284737E+09 | 0.432428E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.268665E+09 | 0.405907E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.149988E+09 | 0.224587E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.109487E+09 | 0.163198E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.219487E+10 | 0.329989E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 63751110.08 | 0.955556E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.309278E+09 | 0.466311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 21739246.14 | 0.329856E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 26488557.09 | 0.403456E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 39045425.44 | 0.590497E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 89107907.16 | 0.134252E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.228822E+09 | 0.344452E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.251294E+09 | 0.377819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.289005E+09 | 0.438682E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.298572E+09 | 0.452997E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.260729E+09 | 0.398109E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.219803E+09 | 0.333301E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 89152154.26 | 0.134020E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 52166498.96 | 0.790718E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.186593E+10 | 0.282508E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 21739246.14 | 0.329856E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.298572E+09 | 0.452997E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.105982E+10 | 0.920707E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.956655E+09 | 0.103064E+10 | 881568.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.105219E+10 | 0.112113E+10 | 752001.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.102888E+10 | 0.149411E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.107231E+10 | 0.299376E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.103884E+10 | 0.323637E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.108128E+10 | 0.346289E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.107968E+10 | 0.402090E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.104571E+10 | 0.347020E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.108025E+10 | 0.330050E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.103623E+10 | 0.198978E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.106411E+10 | 0.128187E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.125960E+11 | 0.283228E+11 | 1633570.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.956655E+09 | 0.920707E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.108128E+10 | 0.402090E+10 | 881568.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 20080516.70 | 0.309817E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 23678199.92 | 0.366750E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 39384652.88 | 0.606168E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 86910397.34 | 0.133156E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.230398E+09 | 0.352920E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.250573E+09 | 0.383316E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.289807E+09 | 0.447640E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.294635E+09 | 0.454947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.256201E+09 | 0.398108E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.214685E+09 | 0.331314E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 87228517.32 | 0.133204E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 48247551.60 | 0.743777E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.184183E+10 | 0.283726E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 20080516.70 | 0.309817E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.294635E+09 | 0.454947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 22711991.05 | 0.354929E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 26901358.44 | 0.423300E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 41534569.59 | 0.648416E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 83560299.27 | 0.130578E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.199878E+09 | 0.313096E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.214892E+09 | 0.336322E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.245472E+09 | 0.387957E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.247175E+09 | 0.390210E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.218040E+09 | 0.346555E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.183903E+09 | 0.289836E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 83739317.70 | 0.130356E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 52250124.08 | 0.816790E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.162006E+10 | 0.254925E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 22711991.05 | 0.354929E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.247175E+09 | 0.390210E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 22653546.49 | 0.354109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 26835170.57 | 0.422343E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 41648095.87 | 0.650444E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 83649484.28 | 0.130762E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.200078E+09 | 0.313520E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.214999E+09 | 0.336610E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.245647E+09 | 0.388370E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.247165E+09 | 0.390335E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.217978E+09 | 0.346579E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.183812E+09 | 0.289797E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 83734329.18 | 0.130390E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 51973663.43 | 0.812909E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.162017E+10 | 0.255034E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 22653546.49 | 0.354109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.247165E+09 | 0.390335E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 84550305.43 | 0.128007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 72840881.48 | 0.112540E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 69748222.35 | 0.107669E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.101638E+09 | 0.157586E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.203411E+09 | 0.315791E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.211931E+09 | 0.328625E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.246521E+09 | 0.386069E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.258799E+09 | 0.404819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.242810E+09 | 0.382661E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.232784E+09 | 0.364543E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.144746E+09 | 0.224258E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.115258E+09 | 0.176929E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.198504E+10 | 0.308950E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 69748222.35 | 0.107669E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.258799E+09 | 0.404819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 86348965.35 | 0.130555E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 73496530.51 | 0.113356E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 72426341.75 | 0.111563E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.107079E+09 | 0.165712E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.219633E+09 | 0.340360E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.228990E+09 | 0.354445E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.266896E+09 | 0.417187E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.277748E+09 | 0.433793E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.259840E+09 | 0.408850E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.248118E+09 | 0.388118E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.151517E+09 | 0.234382E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.119014E+09 | 0.182427E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.211111E+10 | 0.328075E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 72426341.75 | 0.111563E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.277748E+09 | 0.433793E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.175551E+09 | 0.255668E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.194519E+09 | 0.287732E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.213056E+09 | 0.313754E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.322826E+09 | 0.477004E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.560371E+09 | 0.827684E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.571808E+09 | 0.842517E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.620691E+09 | 0.923079E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.614065E+09 | 0.912369E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.560681E+09 | 0.839389E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.530468E+09 | 0.790153E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.304090E+09 | 0.449743E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.231647E+09 | 0.341450E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.489977E+10 | 0.726054E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.175551E+09 | 0.255668E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.620691E+09 | 0.923079E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 57960658.72 | 0.868833E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 95964035.10 | 0.143391E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.150708E+09 | 0.223499E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.282920E+09 | 0.420101E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.553395E+09 | 0.823028E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.578144E+09 | 0.858038E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.618830E+09 | 0.926616E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.589405E+09 | 0.881694E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.507662E+09 | 0.764752E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.422538E+09 | 0.632271E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.171678E+09 | 0.255172E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.107351E+09 | 0.160812E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.413656E+10 | 0.617626E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 57960658.72 | 0.868833E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.618830E+09 | 0.926616E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MSE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.169935E+09 | 0.251769E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.186232E+09 | 0.280437E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.211836E+09 | 0.318062E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.314441E+09 | 0.473681E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.560729E+09 | 0.845065E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.568096E+09 | 0.853809E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.620720E+09 | 0.941483E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.604446E+09 | 0.916107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.549183E+09 | 0.838706E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.516393E+09 | 0.785016E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.297082E+09 | 0.447821E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.218621E+09 | 0.328353E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.481771E+10 | 0.728031E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.169935E+09 | 0.251769E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.620720E+09 | 0.941483E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 52869994.29 | 0.808513E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 88352891.22 | 0.134394E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.149199E+09 | 0.225796E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.276253E+09 | 0.418286E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.553906E+09 | 0.840885E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.574194E+09 | 0.869666E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.618817E+09 | 0.945462E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.580443E+09 | 0.885915E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.497626E+09 | 0.764746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.410995E+09 | 0.627659E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.166813E+09 | 0.252640E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 97957063.60 | 0.149743E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.406743E+10 | 0.619604E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 52869994.29 | 0.808513E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.618817E+09 | 0.945462E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 62348675.21 | 0.959983E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 94953786.99 | 0.146265E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.143524E+09 | 0.219897E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.238775E+09 | 0.367831E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.454701E+09 | 0.702491E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.470061E+09 | 0.724983E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.508201E+09 | 0.791132E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.480772E+09 | 0.747335E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.420859E+09 | 0.659102E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.351215E+09 | 0.545457E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.165370E+09 | 0.253935E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.109836E+09 | 0.169330E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.350062E+10 | 0.542376E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 62348675.21 | 0.959983E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.508201E+09 | 0.791132E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 62254553.49 | 0.958783E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 94741612.48 | 0.145967E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.143816E+09 | 0.220431E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.239173E+09 | 0.368571E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.455038E+09 | 0.703268E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.470239E+09 | 0.725518E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.508492E+09 | 0.791866E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.480745E+09 | 0.747557E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.420762E+09 | 0.659185E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.351071E+09 | 0.545434E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.165350E+09 | 0.254002E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.109216E+09 | 0.168452E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.350090E+10 | 0.542613E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 62254553.49 | 0.958783E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.508492E+09 | 0.791866E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.204842E+09 | 0.306097E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.203477E+09 | 0.309328E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.209362E+09 | 0.317568E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.278619E+09 | 0.426017E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.461976E+09 | 0.707149E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.464167E+09 | 0.709115E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.510518E+09 | 0.787496E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.505421E+09 | 0.778405E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.473527E+09 | 0.735007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.457015E+09 | 0.704848E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.297588E+09 | 0.454812E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.247450E+09 | 0.375052E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.431396E+10 | 0.661089E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.203477E+09 | 0.306097E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.510518E+09 | 0.787496E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.204872E+09 | 0.306240E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.203351E+09 | 0.309235E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.209736E+09 | 0.318245E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.278973E+09 | 0.426708E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.462324E+09 | 0.707932E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.464368E+09 | 0.709667E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.510827E+09 | 0.788241E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.505384E+09 | 0.778619E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.473394E+09 | 0.735065E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.456857E+09 | 0.704864E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.297647E+09 | 0.455071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.246901E+09 | 0.374365E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.431463E+10 | 0.661425E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.203351E+09 | 0.306240E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.510827E+09 | 0.788241E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 69553438.90 | 0.856541E+09 | 0.129424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 81085872.43 | 0.107111E+10 | 96226059.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 93125842.87 | 0.127939E+10 | 81897006.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.154495E+09 | 0.226554E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.309394E+09 | 0.450788E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.321203E+09 | 0.466790E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.347150E+09 | 0.509184E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.341555E+09 | 0.500756E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.301276E+09 | 0.445394E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.276902E+09 | 0.408208E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.124606E+09 | 0.184214E+10 | 987744.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 95619049.52 | 0.129778E+10 | 96011435.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.251596E+10 | 0.364237E+11 | 0.404546E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 69553438.90 | 0.856541E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.347150E+09 | 0.509184E+10 | 0.129424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 49631363.95 | 0.327756E+09 | 0.343681E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 51839500.15 | 0.516536E+09 | 0.196842E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 70047281.43 | 0.904269E+09 | 0.115993E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.134642E+09 | 0.197710E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.306776E+09 | 0.448759E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.325355E+09 | 0.474927E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.347256E+09 | 0.511345E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.329244E+09 | 0.484429E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.274246E+09 | 0.406438E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.222028E+09 | 0.327351E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 67064266.06 | 0.984303E+09 | 7852197.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 58974998.75 | 0.625863E+09 | 0.213875E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.223710E+10 | 0.318683E+11 | 0.878243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 49631363.95 | 0.327756E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.347256E+09 | 0.511345E+10 | 0.343681E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TSE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 64203533.59 | 0.805906E+09 | 0.124043E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 75777371.29 | 0.102515E+10 | 91568066.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 90952251.64 | 0.128460E+10 | 78181763.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.148370E+09 | 0.222841E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.308133E+09 | 0.459698E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.317737E+09 | 0.472680E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.345637E+09 | 0.518970E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.334773E+09 | 0.502430E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.294098E+09 | 0.445064E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.268169E+09 | 0.405065E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.120397E+09 | 0.182137E+10 | 1147725.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 89086959.08 | 0.122886E+10 | 98203273.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.245733E+10 | 0.364334E+11 | 0.393143E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 64203533.59 | 0.805906E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.345637E+09 | 0.518970E+10 | 0.124043E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 45652802.85 | 0.299631E+09 | 0.326974E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 46875868.30 | 0.470611E+09 | 0.186929E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 69009651.82 | 0.918296E+09 | 0.111383E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.129115E+09 | 0.194179E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.305298E+09 | 0.457673E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.321406E+09 | 0.480768E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.345388E+09 | 0.521150E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.322582E+09 | 0.486160E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.267725E+09 | 0.406272E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.214661E+09 | 0.324298E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 63842178.51 | 0.959240E+09 | 7878980.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 54868518.33 | 0.580234E+09 | 0.216356E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.218642E+10 | 0.319330E+11 | 0.849521E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 45652802.85 | 0.299631E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.345388E+09 | 0.521150E+10 | 0.326974E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 32901556.48 | 0.306872E+09 | 0.157734E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 39572895.79 | 0.471683E+09 | 97255098.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 58026472.33 | 0.825793E+09 | 45762865.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.113553E+09 | 0.170825E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.257802E+09 | 0.386849E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.271507E+09 | 0.406700E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.292473E+09 | 0.442065E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.274815E+09 | 0.414834E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.231778E+09 | 0.352473E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.185991E+09 | 0.281174E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 59590461.42 | 0.904089E+09 | 415622.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 44470164.31 | 0.567848E+09 | 90388074.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.186248E+10 | 0.276255E+11 | 0.391555E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 32901556.48 | 0.306872E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.292473E+09 | 0.442065E+10 | 0.157734E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 32841455.37 | 0.305488E+09 | 0.158500E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 39445381.29 | 0.469909E+09 | 97580105.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 58188475.23 | 0.829067E+09 | 45730220.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.113613E+09 | 0.171067E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.257881E+09 | 0.387322E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.271477E+09 | 0.407025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.292492E+09 | 0.442492E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.274653E+09 | 0.414961E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.231617E+09 | 0.352544E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.185805E+09 | 0.281152E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 59583838.06 | 0.904858E+09 | 429257.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 44367918.75 | 0.566082E+09 | 91150424.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.186197E+10 | 0.276410E+11 | 0.393390E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 32841455.37 | 0.305488E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.292492E+09 | 0.442492E+10 | 0.158500E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 60953996.36 | 0.877961E+09 | 24763258.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 72923588.68 | 0.105993E+10 | 31188259.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 82329667.38 | 0.121016E+10 | 26181922.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.133142E+09 | 0.199756E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.260543E+09 | 0.388853E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.267505E+09 | 0.398377E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.292526E+09 | 0.439787E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.287218E+09 | 0.431389E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.258786E+09 | 0.391938E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.240781E+09 | 0.363401E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.119944E+09 | 0.181420E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 88135157.64 | 0.129379E+10 | 29916598.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.216479E+10 | 0.323911E+11 | 0.112050E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 60953996.36 | 0.877961E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.292526E+09 | 0.439787E+10 | 31188259.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 61093210.69 | 0.880694E+09 | 24815251.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 72900868.91 | 0.106038E+10 | 31320993.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 82610470.31 | 0.121575E+10 | 26167596.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.133216E+09 | 0.200056E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.260634E+09 | 0.389332E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.267501E+09 | 0.398717E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.292562E+09 | 0.440224E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.287049E+09 | 0.431520E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.258593E+09 | 0.391996E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.240571E+09 | 0.363425E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.119980E+09 | 0.181649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 87952586.17 | 0.129208E+10 | 30068101.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.216466E+10 | 0.324181E+11 | 0.112372E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61093210.69 | 0.880694E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.292562E+09 | 0.440224E+10 | 31320993.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 70924260.74 | 0.00 | 0.00 | 863907.23 | 0.263918E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 64004363.11 | 0.00 | 0.00 | 0.00 | 0.240228E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 63751110.08 | 0.00 | 0.00 | 0.00 | 0.240782E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.106537E+09 | 0.00 | 0.00 | 0.00 | 0.408027E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.231329E+09 | 0.00 | 0.00 | 0.00 | 0.909823E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.247278E+09 | 0.00 | 0.00 | 0.00 | 0.979709E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.288896E+09 | 0.00 | 0.00 | 0.00 | 0.114974E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.309278E+09 | 0.00 | 0.00 | 0.00 | 0.122258E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.284737E+09 | 0.00 | 0.00 | 0.00 | 0.111278E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.268665E+09 | 0.00 | 0.00 | 0.00 | 0.104208E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.149988E+09 | 0.00 | 0.00 | 0.00 | 0.565312E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.109487E+09 | 0.00 | 0.00 | 1203807.08 | 0.411116E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.219487E+10 | 0.00 | 0.00 | 2067714.31 | 0.854610E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 63751110.08 | 0.00 | 0.00 | 0.00 | 0.240228E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.309278E+09 | 0.00 | 0.00 | 1203807.08 | 0.122258E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 21739246.14 | 0.00 | 0.00 | 0.00 | 82185949.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 26488557.09 | 0.00 | 0.00 | 0.00 | 0.100654E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 39045425.44 | 0.00 | 0.00 | 0.00 | 0.148906E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 89107907.16 | 0.00 | 0.00 | 0.00 | 0.343515E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.228822E+09 | 0.00 | 0.00 | 0.00 | 0.903370E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.251294E+09 | 0.00 | 0.00 | 0.00 | 0.999287E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.289005E+09 | 0.00 | 0.00 | 0.00 | 0.115443E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.298572E+09 | 0.00 | 0.00 | 0.00 | 0.118508E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.260729E+09 | 0.00 | 0.00 | 0.00 | 0.102333E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.219803E+09 | 0.00 | 0.00 | 0.00 | 0.858267E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 89152154.26 | 0.00 | 0.00 | 0.00 | 0.339735E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 52166498.96 | 0.00 | 0.00 | 0.00 | 0.198735E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.186593E+10 | 0.00 | 0.00 | 0.00 | 0.733750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 21739246.14 | 0.00 | 0.00 | 0.00 | 82185949.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.298572E+09 | 0.00 | 0.00 | 0.00 | 0.118508E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.105982E+10 | 0.00 | 0.00 | 7791931.57 | 0.233158E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.956655E+09 | 0.00 | 0.00 | 5796439.13 | 0.258413E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.105219E+10 | 0.00 | 0.00 | 1680669.54 | 0.282952E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.102888E+10 | 0.00 | 0.00 | 0.00 | 0.379137E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.107231E+10 | 0.00 | 0.00 | 0.00 | 0.759932E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.103884E+10 | 0.00 | 0.00 | 0.00 | 0.823264E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.108128E+10 | 0.00 | 0.00 | 0.00 | 0.870458E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.107968E+10 | 0.00 | 0.00 | 0.00 | 0.100476E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.104571E+10 | 0.00 | 0.00 | 0.00 | 0.848774E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.108025E+10 | 0.00 | 0.00 | 0.00 | 0.818127E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.103623E+10 | 0.00 | 0.00 | 0.00 | 0.494516E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.106411E+10 | 0.00 | 0.00 | 3825706.80 | 0.321270E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.125960E+11 | 0.00 | 0.00 | 19094747.04 | 0.709476E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.956655E+09 | 0.00 | 0.00 | 0.00 | 0.233158E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.108128E+10 | 0.00 | 0.00 | 7791931.57 | 0.100476E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 20080516.70 | 0.00 | 0.00 | 0.00 | 77042370.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 23678199.92 | 0.00 | 0.00 | 0.00 | 91358966.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 39384652.88 | 0.00 | 0.00 | 0.00 | 0.152458E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 86910397.34 | 0.00 | 0.00 | 0.00 | 0.339840E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.230398E+09 | 0.00 | 0.00 | 0.00 | 0.922412E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.250573E+09 | 0.00 | 0.00 | 0.00 | 0.101060E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.289807E+09 | 0.00 | 0.00 | 0.00 | 0.117422E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.294635E+09 | 0.00 | 0.00 | 0.00 | 0.118631E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.256201E+09 | 0.00 | 0.00 | 0.00 | 0.102006E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.214685E+09 | 0.00 | 0.00 | 0.00 | 0.850492E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 87228517.32 | 0.00 | 0.00 | 0.00 | 0.337117E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 48247551.60 | 0.00 | 0.00 | 0.00 | 0.186541E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.184183E+10 | 0.00 | 0.00 | 0.00 | 0.734845E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 20080516.70 | 0.00 | 0.00 | 0.00 | 77042370.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.294635E+09 | 0.00 | 0.00 | 0.00 | 0.118631E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 22711991.05 | 0.00 | 0.00 | 642512.56 | 88621904.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 26901358.44 | 0.00 | 0.00 | 0.00 | 0.105562E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 41534569.59 | 0.00 | 0.00 | 0.00 | 0.163371E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 83560299.27 | 0.00 | 0.00 | 0.00 | 0.332337E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.199878E+09 | 0.00 | 0.00 | 0.00 | 0.815881E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.214892E+09 | 0.00 | 0.00 | 0.00 | 0.884176E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.245472E+09 | 0.00 | 0.00 | 0.00 | 0.101499E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.247175E+09 | 0.00 | 0.00 | 0.00 | 0.101584E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.218040E+09 | 0.00 | 0.00 | 0.00 | 0.885646E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.183903E+09 | 0.00 | 0.00 | 0.00 | 0.742849E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 83739317.70 | 0.00 | 0.00 | 0.00 | 0.329507E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 52250124.08 | 0.00 | 0.00 | 898195.91 | 0.205256E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.162006E+10 | 0.00 | 0.00 | 1540708.47 | 0.658404E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 22711991.05 | 0.00 | 0.00 | 0.00 | 88621904.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.247175E+09 | 0.00 | 0.00 | 898195.91 | 0.101584E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 22653546.49 | 0.00 | 0.00 | 642687.09 | 88419179.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 26835170.57 | 0.00 | 0.00 | 0.00 | 0.105333E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 41648095.87 | 0.00 | 0.00 | 0.00 | 0.163867E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 83649484.28 | 0.00 | 0.00 | 0.00 | 0.332788E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.200078E+09 | 0.00 | 0.00 | 0.00 | 0.816932E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.214999E+09 | 0.00 | 0.00 | 0.00 | 0.884879E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.245647E+09 | 0.00 | 0.00 | 0.00 | 0.101601E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.247165E+09 | 0.00 | 0.00 | 0.00 | 0.101611E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.217978E+09 | 0.00 | 0.00 | 0.00 | 0.885661E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.183812E+09 | 0.00 | 0.00 | 0.00 | 0.742716E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 83734329.18 | 0.00 | 0.00 | 0.00 | 0.329582E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 51973663.43 | 0.00 | 0.00 | 898565.01 | 0.204248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.162017E+10 | 0.00 | 0.00 | 1541252.10 | 0.658654E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 22653546.49 | 0.00 | 0.00 | 0.00 | 88419179.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.247165E+09 | 0.00 | 0.00 | 898565.01 | 0.101611E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 84550305.43 | 0.00 | 0.00 | 3629856.79 | 0.324244E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 72840881.48 | 0.00 | 0.00 | 643317.62 | 0.281585E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 69748222.35 | 0.00 | 0.00 | 29872.98 | 0.271312E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.101638E+09 | 0.00 | 0.00 | 0.00 | 0.401059E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.203411E+09 | 0.00 | 0.00 | 0.00 | 0.825812E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.211931E+09 | 0.00 | 0.00 | 0.00 | 0.867357E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.246521E+09 | 0.00 | 0.00 | 0.00 | 0.101390E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.258799E+09 | 0.00 | 0.00 | 0.00 | 0.105755E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.242810E+09 | 0.00 | 0.00 | 0.00 | 0.980452E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.232784E+09 | 0.00 | 0.00 | 0.00 | 0.932417E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.144746E+09 | 0.00 | 0.00 | 0.00 | 0.562830E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.115258E+09 | 0.00 | 0.00 | 1581733.30 | 0.445909E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.198504E+10 | 0.00 | 0.00 | 5884780.68 | 0.796443E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 69748222.35 | 0.00 | 0.00 | 0.00 | 0.271312E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.258799E+09 | 0.00 | 0.00 | 3629856.79 | 0.105755E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 86348965.35 | 0.00 | 0.00 | 3793640.38 | 0.330463E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 73496530.51 | 0.00 | 0.00 | 588406.95 | 0.283555E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 72426341.75 | 0.00 | 0.00 | 89490.86 | 0.281102E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.107079E+09 | 0.00 | 0.00 | 0.00 | 0.421478E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.219633E+09 | 0.00 | 0.00 | 0.00 | 0.888742E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.228990E+09 | 0.00 | 0.00 | 0.00 | 0.933944E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.266896E+09 | 0.00 | 0.00 | 0.00 | 0.109388E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.277748E+09 | 0.00 | 0.00 | 0.00 | 0.113120E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.259840E+09 | 0.00 | 0.00 | 0.00 | 0.104604E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.248118E+09 | 0.00 | 0.00 | 0.00 | 0.990833E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.151517E+09 | 0.00 | 0.00 | 0.00 | 0.587739E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.119014E+09 | 0.00 | 0.00 | 1595005.22 | 0.459441E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.211111E+10 | 0.00 | 0.00 | 6066543.41 | 0.844842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 72426341.75 | 0.00 | 0.00 | 0.00 | 0.281102E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.277748E+09 | 0.00 | 0.00 | 3793640.38 | 0.113120E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.175551E+09 | 0.00 | 0.00 | 325430.67 | 0.644692E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.194519E+09 | 0.00 | 0.00 | 0.00 | 0.718925E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.213056E+09 | 0.00 | 0.00 | 0.00 | 0.791189E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.322826E+09 | 0.00 | 0.00 | 0.00 | 0.121512E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.560371E+09 | 0.00 | 0.00 | 0.00 | 0.217385E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.571808E+09 | 0.00 | 0.00 | 0.00 | 0.223555E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.620691E+09 | 0.00 | 0.00 | 0.00 | 0.244049E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.614065E+09 | 0.00 | 0.00 | 0.00 | 0.240264E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.560681E+09 | 0.00 | 0.00 | 0.00 | 0.216908E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.530468E+09 | 0.00 | 0.00 | 0.00 | 0.203717E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.304090E+09 | 0.00 | 0.00 | 0.00 | 0.113316E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.231647E+09 | 0.00 | 0.00 | 588503.49 | 0.859650E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.489977E+10 | 0.00 | 0.00 | 913934.16 | 0.188215E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.175551E+09 | 0.00 | 0.00 | 0.00 | 0.644692E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.620691E+09 | 0.00 | 0.00 | 588503.49 | 0.244049E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 57960658.72 | 0.00 | 0.00 | 0.00 | 0.216455E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 95964035.10 | 0.00 | 0.00 | 0.00 | 0.358797E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.150708E+09 | 0.00 | 0.00 | 0.00 | 0.564558E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.282920E+09 | 0.00 | 0.00 | 0.00 | 0.107151E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.553395E+09 | 0.00 | 0.00 | 0.00 | 0.215652E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.578144E+09 | 0.00 | 0.00 | 0.00 | 0.227050E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.618830E+09 | 0.00 | 0.00 | 0.00 | 0.244408E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.589405E+09 | 0.00 | 0.00 | 0.00 | 0.231728E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.507662E+09 | 0.00 | 0.00 | 0.00 | 0.197367E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.422538E+09 | 0.00 | 0.00 | 0.00 | 0.163525E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.171678E+09 | 0.00 | 0.00 | 0.00 | 0.647905E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.107351E+09 | 0.00 | 0.00 | 0.00 | 0.404672E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.413656E+10 | 0.00 | 0.00 | 0.00 | 0.160612E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 57960658.72 | 0.00 | 0.00 | 0.00 | 0.216455E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.618830E+09 | 0.00 | 0.00 | 0.00 | 0.244408E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MSE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.169935E+09 | 0.00 | 0.00 | 292675.75 | 0.634254E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.186232E+09 | 0.00 | 0.00 | 0.00 | 0.699566E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.211836E+09 | 0.00 | 0.00 | 0.00 | 0.799838E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.314441E+09 | 0.00 | 0.00 | 0.00 | 0.120295E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.560729E+09 | 0.00 | 0.00 | 0.00 | 0.221052E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.568096E+09 | 0.00 | 0.00 | 0.00 | 0.225734E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.620720E+09 | 0.00 | 0.00 | 0.00 | 0.248084E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.604446E+09 | 0.00 | 0.00 | 0.00 | 0.240400E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.549183E+09 | 0.00 | 0.00 | 0.00 | 0.215959E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.516393E+09 | 0.00 | 0.00 | 0.00 | 0.201600E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.297082E+09 | 0.00 | 0.00 | 0.00 | 0.112512E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.218621E+09 | 0.00 | 0.00 | 428529.90 | 0.824771E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.481771E+10 | 0.00 | 0.00 | 721205.65 | 0.188148E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.169935E+09 | 0.00 | 0.00 | 0.00 | 0.634254E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.620720E+09 | 0.00 | 0.00 | 428529.90 | 0.248084E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 52869994.29 | 0.00 | 0.00 | 0.00 | 0.200871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 88352891.22 | 0.00 | 0.00 | 0.00 | 0.335973E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.149199E+09 | 0.00 | 0.00 | 0.00 | 0.568589E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.276253E+09 | 0.00 | 0.00 | 0.00 | 0.106354E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.553906E+09 | 0.00 | 0.00 | 0.00 | 0.219389E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.574194E+09 | 0.00 | 0.00 | 0.00 | 0.229219E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.618817E+09 | 0.00 | 0.00 | 0.00 | 0.248473E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.580443E+09 | 0.00 | 0.00 | 0.00 | 0.232008E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.497626E+09 | 0.00 | 0.00 | 0.00 | 0.196689E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.410995E+09 | 0.00 | 0.00 | 0.00 | 0.161739E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.166813E+09 | 0.00 | 0.00 | 0.00 | 0.639946E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 97957063.60 | 0.00 | 0.00 | 0.00 | 0.375661E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.406743E+10 | 0.00 | 0.00 | 0.00 | 0.160598E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 52869994.29 | 0.00 | 0.00 | 0.00 | 0.200871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.618817E+09 | 0.00 | 0.00 | 0.00 | 0.248473E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 62348675.21 | 0.00 | 0.00 | 573453.13 | 0.240013E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 94953786.99 | 0.00 | 0.00 | 0.00 | 0.366365E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.143524E+09 | 0.00 | 0.00 | 0.00 | 0.554834E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.238775E+09 | 0.00 | 0.00 | 0.00 | 0.934010E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.454701E+09 | 0.00 | 0.00 | 0.00 | 0.183190E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.470061E+09 | 0.00 | 0.00 | 0.00 | 0.190971E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.508201E+09 | 0.00 | 0.00 | 0.00 | 0.207660E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.480772E+09 | 0.00 | 0.00 | 0.00 | 0.195509E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.420859E+09 | 0.00 | 0.00 | 0.00 | 0.169111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.351215E+09 | 0.00 | 0.00 | 0.00 | 0.140411E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.165370E+09 | 0.00 | 0.00 | 0.00 | 0.643251E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.109836E+09 | 0.00 | 0.00 | 148693.44 | 0.426241E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.350062E+10 | 0.00 | 0.00 | 722146.57 | 0.140332E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 62348675.21 | 0.00 | 0.00 | 0.00 | 0.240013E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.508201E+09 | 0.00 | 0.00 | 573453.13 | 0.207660E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 62254553.49 | 0.00 | 0.00 | 565668.85 | 0.239717E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 94741612.48 | 0.00 | 0.00 | 0.00 | 0.365651E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.143816E+09 | 0.00 | 0.00 | 0.00 | 0.556128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.239173E+09 | 0.00 | 0.00 | 0.00 | 0.935826E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.455038E+09 | 0.00 | 0.00 | 0.00 | 0.183381E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.470239E+09 | 0.00 | 0.00 | 0.00 | 0.191101E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.508492E+09 | 0.00 | 0.00 | 0.00 | 0.207841E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.480745E+09 | 0.00 | 0.00 | 0.00 | 0.195558E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.420762E+09 | 0.00 | 0.00 | 0.00 | 0.169124E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.351071E+09 | 0.00 | 0.00 | 0.00 | 0.140399E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.165350E+09 | 0.00 | 0.00 | 0.00 | 0.643369E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.109216E+09 | 0.00 | 0.00 | 148730.09 | 0.423998E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.350090E+10 | 0.00 | 0.00 | 714398.95 | 0.140387E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 62254553.49 | 0.00 | 0.00 | 0.00 | 0.239717E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.508492E+09 | 0.00 | 0.00 | 565668.85 | 0.207841E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.204842E+09 | 0.00 | 0.00 | 2626372.16 | 0.774784E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.203477E+09 | 0.00 | 0.00 | 928790.30 | 0.774577E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.209362E+09 | 0.00 | 0.00 | 178048.63 | 0.801009E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.278619E+09 | 0.00 | 0.00 | 0.00 | 0.108135E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.461976E+09 | 0.00 | 0.00 | 0.00 | 0.184972E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.464167E+09 | 0.00 | 0.00 | 0.00 | 0.187412E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.510518E+09 | 0.00 | 0.00 | 0.00 | 0.207326E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.505421E+09 | 0.00 | 0.00 | 0.00 | 0.204207E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.473527E+09 | 0.00 | 0.00 | 0.00 | 0.189046E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.457015E+09 | 0.00 | 0.00 | 0.00 | 0.181006E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.297588E+09 | 0.00 | 0.00 | 0.00 | 0.114256E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.247450E+09 | 0.00 | 0.00 | 1568571.33 | 0.944906E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.431396E+10 | 0.00 | 0.00 | 5301782.41 | 0.170589E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.203477E+09 | 0.00 | 0.00 | 0.00 | 0.774577E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.510518E+09 | 0.00 | 0.00 | 2626372.16 | 0.207326E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.204872E+09 | 0.00 | 0.00 | 2625935.31 | 0.775119E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.203351E+09 | 0.00 | 0.00 | 928190.51 | 0.774318E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.209736E+09 | 0.00 | 0.00 | 178060.07 | 0.802677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.278973E+09 | 0.00 | 0.00 | 0.00 | 0.108303E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.462324E+09 | 0.00 | 0.00 | 0.00 | 0.185168E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.464368E+09 | 0.00 | 0.00 | 0.00 | 0.187550E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.510827E+09 | 0.00 | 0.00 | 0.00 | 0.207514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.505384E+09 | 0.00 | 0.00 | 0.00 | 0.204255E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.473394E+09 | 0.00 | 0.00 | 0.00 | 0.189051E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.456857E+09 | 0.00 | 0.00 | 0.00 | 0.181000E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.297647E+09 | 0.00 | 0.00 | 0.00 | 0.114313E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.246901E+09 | 0.00 | 0.00 | 1568901.43 | 0.943111E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.431463E+10 | 0.00 | 0.00 | 5301087.32 | 0.170668E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.203351E+09 | 0.00 | 0.00 | 0.00 | 0.774318E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.510827E+09 | 0.00 | 0.00 | 2625935.31 | 0.207514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 69553438.90 | 0.00 | 0.00 | 52976383.69 | 0.212062E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 81085872.43 | 0.00 | 0.00 | 39403451.98 | 0.263561E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 93125842.87 | 0.00 | 0.00 | 27043680.80 | 0.319874E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.154495E+09 | 0.00 | 0.00 | 0.00 | 0.577114E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.309394E+09 | 0.00 | 0.00 | 0.00 | 0.118828E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.321203E+09 | 0.00 | 0.00 | 0.00 | 0.124261E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.347150E+09 | 0.00 | 0.00 | 0.00 | 0.134996E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.341555E+09 | 0.00 | 0.00 | 0.00 | 0.132227E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.301276E+09 | 0.00 | 0.00 | 0.00 | 0.115379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.276902E+09 | 0.00 | 0.00 | 0.00 | 0.105430E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.124606E+09 | 0.00 | 0.00 | 298782.64 | 0.461091E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 95619049.52 | 0.00 | 0.00 | 35935588.26 | 0.323146E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.251596E+10 | 0.00 | 0.00 | 0.155658E+09 | 0.946806E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 69553438.90 | 0.00 | 0.00 | 0.00 | 0.212062E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.347150E+09 | 0.00 | 0.00 | 52976383.69 | 0.134996E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 49631363.95 | 0.00 | 0.00 | 0.121428E+09 | 80944555.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 51839500.15 | 0.00 | 0.00 | 71871057.76 | 0.128105E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 70047281.43 | 0.00 | 0.00 | 37729225.88 | 0.227133E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.134642E+09 | 0.00 | 0.00 | 0.00 | 0.505154E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.306776E+09 | 0.00 | 0.00 | 0.00 | 0.118088E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.325355E+09 | 0.00 | 0.00 | 0.00 | 0.126150E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.347256E+09 | 0.00 | 0.00 | 0.00 | 0.135342E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.329244E+09 | 0.00 | 0.00 | 0.00 | 0.127790E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.274246E+09 | 0.00 | 0.00 | 0.00 | 0.105312E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.222028E+09 | 0.00 | 0.00 | 0.00 | 0.850111E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 67064266.06 | 0.00 | 0.00 | 2359118.34 | 0.249599E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 58974998.75 | 0.00 | 0.00 | 73655866.33 | 0.157286E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.223710E+10 | 0.00 | 0.00 | 0.307043E+09 | 0.832514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 49631363.95 | 0.00 | 0.00 | 0.00 | 80944555.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.347256E+09 | 0.00 | 0.00 | 0.121428E+09 | 0.135342E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TSE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 64203533.59 | 0.00 | 0.00 | 51066480.28 | 0.198601E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 75777371.29 | 0.00 | 0.00 | 37360790.18 | 0.251036E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 90952251.64 | 0.00 | 0.00 | 25885559.71 | 0.319343E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.148370E+09 | 0.00 | 0.00 | 0.00 | 0.564501E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.308133E+09 | 0.00 | 0.00 | 0.00 | 0.120477E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.317737E+09 | 0.00 | 0.00 | 0.00 | 0.125154E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.345637E+09 | 0.00 | 0.00 | 0.00 | 0.136880E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.334773E+09 | 0.00 | 0.00 | 0.00 | 0.131985E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.294098E+09 | 0.00 | 0.00 | 0.00 | 0.114700E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.268169E+09 | 0.00 | 0.00 | 0.00 | 0.103991E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.120397E+09 | 0.00 | 0.00 | 347251.84 | 0.453669E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 89086959.08 | 0.00 | 0.00 | 36643290.31 | 0.304627E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.245733E+10 | 0.00 | 0.00 | 0.151303E+09 | 0.942364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 64203533.59 | 0.00 | 0.00 | 0.00 | 0.198601E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.345637E+09 | 0.00 | 0.00 | 51066480.28 | 0.136880E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 45652802.85 | 0.00 | 0.00 | 0.116265E+09 | 73822650.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 46875868.30 | 0.00 | 0.00 | 68388530.87 | 0.116307E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 69009651.82 | 0.00 | 0.00 | 36296813.99 | 0.229575E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.129115E+09 | 0.00 | 0.00 | 0.00 | 0.493669E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.305298E+09 | 0.00 | 0.00 | 0.00 | 0.119700E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.321406E+09 | 0.00 | 0.00 | 0.00 | 0.126949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.345388E+09 | 0.00 | 0.00 | 0.00 | 0.137161E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.322582E+09 | 0.00 | 0.00 | 0.00 | 0.127574E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.267725E+09 | 0.00 | 0.00 | 0.00 | 0.104755E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.214661E+09 | 0.00 | 0.00 | 0.00 | 0.837639E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 63842178.51 | 0.00 | 0.00 | 2372179.22 | 0.242173E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 54868518.33 | 0.00 | 0.00 | 74381774.16 | 0.145174E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.218642E+10 | 0.00 | 0.00 | 0.297704E+09 | 0.829975E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 45652802.85 | 0.00 | 0.00 | 0.00 | 73822650.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.345388E+09 | 0.00 | 0.00 | 0.116265E+09 | 0.137161E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 32901556.48 | 0.00 | 0.00 | 60628063.06 | 75736537.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 39572895.79 | 0.00 | 0.00 | 38969951.64 | 0.116984E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 58026472.33 | 0.00 | 0.00 | 15514111.10 | 0.207014E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.113553E+09 | 0.00 | 0.00 | 0.00 | 0.435195E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.257802E+09 | 0.00 | 0.00 | 0.00 | 0.101421E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.271507E+09 | 0.00 | 0.00 | 0.00 | 0.107653E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.292473E+09 | 0.00 | 0.00 | 0.00 | 0.116583E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.274815E+09 | 0.00 | 0.00 | 0.00 | 0.109062E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.231778E+09 | 0.00 | 0.00 | 0.00 | 0.909406E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.185991E+09 | 0.00 | 0.00 | 0.00 | 0.727583E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 59590461.42 | 0.00 | 0.00 | 125905.08 | 0.228212E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 44470164.31 | 0.00 | 0.00 | 33844455.41 | 0.141911E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.186248E+10 | 0.00 | 0.00 | 0.149082E+09 | 0.718923E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 32901556.48 | 0.00 | 0.00 | 0.00 | 75736537.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.292473E+09 | 0.00 | 0.00 | 60628063.06 | 0.116583E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 32841455.37 | 0.00 | 0.00 | 60872227.69 | 75385420.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 39445381.29 | 0.00 | 0.00 | 39066055.14 | 0.116530E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 58188475.23 | 0.00 | 0.00 | 15505069.48 | 0.207806E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.113613E+09 | 0.00 | 0.00 | 0.00 | 0.435751E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.257881E+09 | 0.00 | 0.00 | 0.00 | 0.101528E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.271477E+09 | 0.00 | 0.00 | 0.00 | 0.107721E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.292492E+09 | 0.00 | 0.00 | 0.00 | 0.116678E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.274653E+09 | 0.00 | 0.00 | 0.00 | 0.109080E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.231617E+09 | 0.00 | 0.00 | 0.00 | 0.909462E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.185805E+09 | 0.00 | 0.00 | 0.00 | 0.727424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 59583838.06 | 0.00 | 0.00 | 130039.10 | 0.228361E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 44367918.75 | 0.00 | 0.00 | 34080485.89 | 0.141445E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.186197E+10 | 0.00 | 0.00 | 0.149654E+09 | 0.719223E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 32841455.37 | 0.00 | 0.00 | 0.00 | 75385420.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.292492E+09 | 0.00 | 0.00 | 60872227.69 | 0.116678E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 60953996.36 | 0.00 | 0.00 | 14544596.49 | 0.217670E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 72923588.68 | 0.00 | 0.00 | 15679165.69 | 0.260968E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 82329667.38 | 0.00 | 0.00 | 9078462.87 | 0.302347E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.133142E+09 | 0.00 | 0.00 | 0.00 | 0.507579E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.260543E+09 | 0.00 | 0.00 | 0.00 | 0.102179E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.267505E+09 | 0.00 | 0.00 | 0.00 | 0.105732E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.292526E+09 | 0.00 | 0.00 | 0.00 | 0.116237E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.287218E+09 | 0.00 | 0.00 | 0.00 | 0.113590E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.258786E+09 | 0.00 | 0.00 | 0.00 | 0.101184E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.240781E+09 | 0.00 | 0.00 | 0.00 | 0.935602E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.119944E+09 | 0.00 | 0.00 | 0.00 | 0.452880E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 88135157.64 | 0.00 | 0.00 | 13356543.83 | 0.321649E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.216479E+10 | 0.00 | 0.00 | 52658768.88 | 0.838792E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 60953996.36 | 0.00 | 0.00 | 0.00 | 0.217670E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.292526E+09 | 0.00 | 0.00 | 15679165.69 | 0.116237E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 61093210.69 | 0.00 | 0.00 | 14566990.45 | 0.218315E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 72900868.91 | 0.00 | 0.00 | 15720052.21 | 0.261033E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 82610470.31 | 0.00 | 0.00 | 9104679.87 | 0.303631E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.133216E+09 | 0.00 | 0.00 | 0.00 | 0.508228E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.260634E+09 | 0.00 | 0.00 | 0.00 | 0.102289E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.267501E+09 | 0.00 | 0.00 | 0.00 | 0.105807E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.292562E+09 | 0.00 | 0.00 | 0.00 | 0.116336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.287049E+09 | 0.00 | 0.00 | 0.00 | 0.113606E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.258593E+09 | 0.00 | 0.00 | 0.00 | 0.101183E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.240571E+09 | 0.00 | 0.00 | 0.00 | 0.935474E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.119980E+09 | 0.00 | 0.00 | 0.00 | 0.453336E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 87952586.17 | 0.00 | 0.00 | 13410343.40 | 0.321156E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.216466E+10 | 0.00 | 0.00 | 52802065.93 | 0.839339E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 61093210.69 | 0.00 | 0.00 | 0.00 | 0.218315E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.292562E+09 | 0.00 | 0.00 | 15720052.21 | 0.116336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.138241E+09 | 32972484.12 | 0.00 | 2010192.31 | 10351057.12 | 0.00 | 0.150589E+09 | 0.00 | 0.35 |
| February | 0.108316E+09 | 41614340.62 | 0.00 | 1083391.26 | 14262990.48 | 0.00 | 82296354.45 | 0.00 | 0.35 |
| March | 0.121208E+09 | 68072765.00 | 0.00 | 840208.12 | 18830497.02 | 0.00 | 60969968.14 | 0.00 | 0.35 |
| April | 30822293.17 | 0.166715E+09 | 0.00 | 936074.89 | 30826184.20 | 0.00 | 40759458.14 | 0.00 | 0.36 |
| May | 0.00 | 0.717057E+09 | 0.00 | 0.00 | 30560761.70 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.824340E+09 | 0.00 | 0.00 | 13053167.90 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.105082E+10 | 0.00 | 0.00 | 14286545.82 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.953468E+09 | 0.00 | 0.00 | 28123280.29 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.807071E+09 | 0.00 | 0.00 | 50922840.10 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 12820622.22 | 0.599091E+09 | 0.00 | 740635.19 | 32025146.56 | 0.00 | 23679122.84 | 0.00 | 0.36 |
| November | 29628227.19 | 0.165546E+09 | 0.00 | 3122407.66 | 24071664.65 | 0.00 | 0.105057E+09 | 0.00 | 0.35 |
| December | 76049076.46 | 93112342.30 | 0.00 | 2420941.44 | 24633815.03 | 0.00 | 0.158456E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.517086E+09 | 0.551988E+10 | 0.00 | 11153850.88 | 0.291948E+09 | 0.00 | 0.621807E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 32972484.12 | 0.00 | 0.00 | 10351057.12 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.138241E+09 | 0.105082E+10 | 0.00 | 3122407.66 | 50922840.10 | 0.00 | 0.158456E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.244251E+09 | 19328800.33 | 0.00 | 267678.25 | 8444359.34 | 0.00 | 35430769.26 | 0.00 | 0.35 |
| February | 0.171208E+09 | 24960276.56 | 0.00 | 284775.25 | 11327027.41 | 0.00 | 22839026.96 | 0.00 | 0.35 |
| March | 0.141533E+09 | 54039624.69 | 0.00 | 325058.15 | 16391225.94 | 0.00 | 40599466.11 | 0.00 | 0.35 |
| April | 39158200.42 | 0.155628E+09 | 0.00 | 537194.37 | 28484172.71 | 0.00 | 35463308.80 | 0.00 | 0.36 |
| May | 0.00 | 0.715632E+09 | 0.00 | 0.00 | 30371320.79 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.829040E+09 | 0.00 | 0.00 | 12574271.45 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.105283E+10 | 0.00 | 0.00 | 13957764.21 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.944543E+09 | 0.00 | 0.00 | 27939932.10 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 14624.81 | 0.784570E+09 | 0.00 | 36.09 | 48969147.07 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 13436750.94 | 0.563126E+09 | 0.00 | 455840.97 | 31876559.93 | 0.00 | 24253172.11 | 0.00 | 0.36 |
| November | 44048392.38 | 0.143502E+09 | 0.00 | 1166837.18 | 22498601.52 | 0.00 | 99346281.64 | 0.00 | 0.35 |
| December | 0.162335E+09 | 75786184.72 | 0.00 | 499774.49 | 21660195.42 | 0.00 | 72945969.81 | 0.00 | 0.35 |
| Annual Sum or Average | 0.815985E+09 | 0.536299E+10 | 0.00 | 3537194.75 | 0.274495E+09 | 0.00 | 0.330878E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 19328800.33 | 0.00 | 0.00 | 8444359.34 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.244251E+09 | 0.105283E+10 | 0.00 | 1166837.18 | 48969147.07 | 0.00 | 99346281.64 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.113046E+10 | 49726545.64 | 0.00 | 1344733.81 | 5554928.93 | 0.00 | 0.194743E+09 | 0.00 | 0.50 |
| February | 0.844332E+09 | 71958597.18 | 0.00 | 1121052.54 | 7406487.00 | 49850.36 | 0.110147E+09 | 0.00 | 0.50 |
| March | 0.775693E+09 | 96871534.63 | 0.00 | 1200673.47 | 14593697.67 | 43454.77 | 0.140556E+09 | 0.00 | 0.50 |
| April | 0.499093E+09 | 0.158877E+09 | 0.00 | 1164000.44 | 42493119.12 | 0.00 | 54259289.77 | 0.00 | 0.50 |
| May | 0.139372E+09 | 0.593826E+09 | 0.00 | 492968.59 | 0.150328E+09 | 0.00 | 32240.65 | 0.00 | 0.51 |
| June | 0.116264E+09 | 0.694465E+09 | 0.00 | 425750.27 | 0.186006E+09 | 0.00 | 7975.31 | 0.00 | 0.52 |
| July | 97354064.75 | 0.772617E+09 | 0.00 | 390446.52 | 0.224069E+09 | 0.00 | 84775.20 | 0.00 | 0.52 |
| August | 0.129472E+09 | 0.848138E+09 | 0.00 | 607339.19 | 0.196754E+09 | 0.00 | 857701.87 | 0.00 | 0.52 |
| September | 0.150631E+09 | 0.675225E+09 | 0.00 | 717846.64 | 0.133112E+09 | 0.00 | 108938.47 | 0.00 | 0.52 |
| October | 0.364275E+09 | 0.512691E+09 | 0.00 | 2066248.67 | 91457808.07 | 0.00 | 43433248.62 | 0.00 | 0.52 |
| November | 0.740389E+09 | 0.184231E+09 | 0.00 | 3249424.62 | 23663120.81 | 0.00 | 96629646.71 | 0.00 | 0.51 |
| December | 0.981064E+09 | 0.111400E+09 | 0.00 | 1815406.17 | 10173331.50 | 0.00 | 0.165381E+09 | 0.00 | 0.50 |
| Annual Sum or Average | 0.596840E+10 | 0.477003E+10 | 0.00 | 14595890.91 | 0.108561E+10 | 93305.13 | 0.806241E+09 | 0.00 | 0.51 |
| Minimum of Months | 97354064.75 | 49726545.64 | 0.00 | 390446.52 | 5554928.93 | 0.00 | 7975.31 | 0.00 | 0.50 |
| Maximum of Months | 0.113046E+10 | 0.848138E+09 | 0.00 | 3249424.62 | 0.224069E+09 | 49850.36 | 0.194743E+09 | 0.00 | 0.52 |
Report: MechanicalVentilationLoadsMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.246900E+09 | 18608665.85 | 0.00 | 249940.02 | 7751494.53 | 0.00 | 34231295.66 | 0.00 | 0.35 |
| February | 0.167719E+09 | 23990490.89 | 0.00 | 265933.22 | 10259283.97 | 0.00 | 29604780.31 | 0.00 | 0.35 |
| March | 0.142223E+09 | 56027812.49 | 0.00 | 305150.34 | 15659284.10 | 0.00 | 40922319.94 | 0.00 | 0.35 |
| April | 40293331.53 | 0.156268E+09 | 0.00 | 521126.56 | 27217896.48 | 0.00 | 35346777.02 | 0.00 | 0.36 |
| May | 0.00 | 0.723696E+09 | 0.00 | 0.00 | 29745627.28 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.835323E+09 | 0.00 | 0.00 | 11636860.26 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.105955E+10 | 0.00 | 0.00 | 13976575.85 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.946698E+09 | 0.00 | 0.00 | 27439182.21 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 13812.77 | 0.785371E+09 | 0.00 | 16.52 | 48585589.85 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 13374841.34 | 0.564307E+09 | 0.00 | 444352.45 | 31348909.25 | 0.00 | 24514265.51 | 0.00 | 0.36 |
| November | 44204430.20 | 0.143261E+09 | 0.00 | 1208956.32 | 21640531.39 | 0.00 | 0.100573E+09 | 0.00 | 0.35 |
| December | 0.166374E+09 | 74122372.05 | 0.00 | 437017.85 | 20515692.96 | 0.00 | 68533333.76 | 0.00 | 0.35 |
| Annual Sum or Average | 0.821102E+09 | 0.538723E+10 | 0.00 | 3432493.28 | 0.265777E+09 | 0.00 | 0.333726E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 18608665.85 | 0.00 | 0.00 | 7751494.53 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.246900E+09 | 0.105955E+10 | 0.00 | 1208956.32 | 48585589.85 | 0.00 | 0.100573E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.212695E+09 | 19003512.85 | 0.00 | 473735.21 | 8072263.56 | 0.00 | 83609025.24 | 0.00 | 0.35 |
| February | 0.136528E+09 | 24530108.47 | 0.00 | 445735.05 | 10737566.01 | 0.00 | 68012779.24 | 0.00 | 0.35 |
| March | 0.121326E+09 | 56001201.75 | 0.00 | 517607.92 | 15996038.18 | 0.00 | 67989384.01 | 0.00 | 0.35 |
| April | 32119471.67 | 0.153857E+09 | 0.00 | 680042.37 | 28268788.29 | 0.00 | 40086550.01 | 0.00 | 0.36 |
| May | 0.00 | 0.709368E+09 | 0.00 | 0.00 | 30545564.88 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.812323E+09 | 0.00 | 0.00 | 13235447.55 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.102970E+10 | 0.00 | 0.00 | 13808108.48 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.917545E+09 | 0.00 | 0.00 | 28342056.18 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 26175.24 | 0.762943E+09 | 0.00 | 384.55 | 48931970.84 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 13070492.25 | 0.548371E+09 | 0.00 | 481865.67 | 31806933.50 | 0.00 | 24750139.60 | 0.00 | 0.36 |
| November | 38794638.94 | 0.139736E+09 | 0.00 | 1371864.92 | 21841657.08 | 0.00 | 0.104990E+09 | 0.00 | 0.35 |
| December | 0.105596E+09 | 74156074.23 | 0.00 | 811655.32 | 21029826.02 | 0.00 | 0.136828E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.660157E+09 | 0.524753E+10 | 0.00 | 4782891.02 | 0.272616E+09 | 0.00 | 0.526266E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 19003512.85 | 0.00 | 0.00 | 8072263.56 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.212695E+09 | 0.102970E+10 | 0.00 | 1371864.92 | 48931970.84 | 0.00 | 0.136828E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.212451E+09 | 18979805.17 | 0.00 | 474138.88 | 8057430.73 | 0.00 | 83980180.16 | 0.00 | 0.35 |
| February | 0.136164E+09 | 24490034.65 | 0.00 | 445480.10 | 10710850.52 | 0.00 | 68475015.18 | 0.00 | 0.35 |
| March | 0.121554E+09 | 56182298.52 | 0.00 | 516977.21 | 16033269.69 | 0.00 | 67847242.47 | 0.00 | 0.35 |
| April | 32128978.08 | 0.154014E+09 | 0.00 | 680498.29 | 28241343.68 | 0.00 | 40068383.34 | 0.00 | 0.36 |
| May | 0.00 | 0.709809E+09 | 0.00 | 0.00 | 30568138.13 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.812650E+09 | 0.00 | 0.00 | 13234581.92 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.103015E+10 | 0.00 | 0.00 | 13823321.75 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.917772E+09 | 0.00 | 0.00 | 28229948.92 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 26067.99 | 0.763020E+09 | 0.00 | 382.52 | 48971486.70 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 13085607.65 | 0.548493E+09 | 0.00 | 480657.01 | 31799985.19 | 0.00 | 24789716.77 | 0.00 | 0.36 |
| November | 38798989.93 | 0.139791E+09 | 0.00 | 1372440.33 | 21750824.24 | 0.00 | 0.105001E+09 | 0.00 | 0.35 |
| December | 0.106619E+09 | 74069164.94 | 0.00 | 802576.09 | 20956058.17 | 0.00 | 0.135806E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.660827E+09 | 0.524942E+10 | 0.00 | 4773150.44 | 0.272377E+09 | 0.00 | 0.525968E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 18979805.17 | 0.00 | 0.00 | 8057430.73 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.212451E+09 | 0.103015E+10 | 0.00 | 1372440.33 | 48971486.70 | 0.00 | 0.135806E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 40975313.93 | 34046557.12 | 0.00 | 2804697.46 | 10286815.15 | 0.00 | 0.251074E+09 | 0.00 | 0.35 |
| February | 61953400.14 | 43774964.78 | 0.00 | 1615828.05 | 13467804.51 | 0.00 | 0.131336E+09 | 0.00 | 0.35 |
| March | 86590065.48 | 70717593.39 | 0.00 | 1205144.06 | 18774972.06 | 0.00 | 99791332.00 | 0.00 | 0.35 |
| April | 30793375.89 | 0.166370E+09 | 0.00 | 1097309.31 | 30176950.31 | 0.00 | 39031865.23 | 0.00 | 0.36 |
| May | 0.00 | 0.709838E+09 | 0.00 | 0.00 | 30557731.39 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.805527E+09 | 0.00 | 0.00 | 13488956.49 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.102577E+10 | 0.00 | 0.00 | 14339207.47 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.926782E+09 | 0.00 | 0.00 | 28766707.56 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 14639.62 | 0.788913E+09 | 0.00 | 449.23 | 51194619.69 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 12995582.71 | 0.589705E+09 | 0.00 | 780115.53 | 31734406.31 | 0.00 | 24111202.91 | 0.00 | 0.36 |
| November | 30185612.36 | 0.164160E+09 | 0.00 | 3446379.50 | 23821558.51 | 0.00 | 0.105415E+09 | 0.00 | 0.35 |
| December | 40420907.69 | 93341080.26 | 0.00 | 2990482.61 | 24717035.35 | 0.00 | 0.198377E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.303929E+09 | 0.541894E+10 | 0.00 | 13940405.74 | 0.291327E+09 | 0.00 | 0.849136E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 34046557.12 | 0.00 | 0.00 | 10286815.15 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 86590065.48 | 0.102577E+10 | 0.00 | 3446379.50 | 51194619.69 | 0.00 | 0.251074E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 42222665.48 | 34610575.46 | 0.00 | 2787975.70 | 10419355.81 | 0.00 | 0.249821E+09 | 0.00 | 0.35 |
| February | 64168885.49 | 44165513.71 | 0.00 | 1587300.24 | 13712655.79 | 0.00 | 0.128907E+09 | 0.00 | 0.35 |
| March | 88250495.22 | 72750162.63 | 0.00 | 1221922.79 | 18651117.08 | 0.00 | 97617191.20 | 0.00 | 0.35 |
| April | 30534929.77 | 0.171390E+09 | 0.00 | 1133794.47 | 30544639.60 | 0.00 | 39015925.92 | 0.00 | 0.36 |
| May | 0.00 | 0.730389E+09 | 0.00 | 0.00 | 31951576.64 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.827649E+09 | 0.00 | 0.00 | 13742898.66 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.105271E+10 | 0.00 | 0.00 | 14356191.88 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.949000E+09 | 0.00 | 0.00 | 28368405.93 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 2308.71 | 0.807241E+09 | 0.00 | 0.00 | 51989639.06 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 13137070.56 | 0.601591E+09 | 0.00 | 811696.74 | 32987092.55 | 0.00 | 23839206.68 | 0.00 | 0.36 |
| November | 30372660.44 | 0.166585E+09 | 0.00 | 3562000.03 | 24515609.15 | 0.00 | 0.104951E+09 | 0.00 | 0.35 |
| December | 40198051.21 | 95139969.31 | 0.00 | 3038025.45 | 25721435.40 | 0.00 | 0.198678E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.308887E+09 | 0.555322E+10 | 0.00 | 14142715.43 | 0.296961E+09 | 0.00 | 0.842829E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 34610575.46 | 0.00 | 0.00 | 10419355.81 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 88250495.22 | 0.105271E+10 | 0.00 | 3562000.03 | 51989639.06 | 0.00 | 0.249821E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.276984E+09 | 70697131.57 | 0.00 | 4816065.48 | 20361794.08 | 0.00 | 0.286656E+09 | 0.00 | 0.35 |
| February | 0.174732E+09 | 0.100483E+09 | 0.00 | 3400265.20 | 31190711.67 | 0.00 | 0.188164E+09 | 0.00 | 0.35 |
| March | 0.180955E+09 | 0.165410E+09 | 0.00 | 3336054.24 | 37248902.67 | 0.00 | 0.175738E+09 | 0.00 | 0.35 |
| April | 54731486.14 | 0.387744E+09 | 0.00 | 3181246.31 | 62458900.13 | 0.00 | 75540131.86 | 0.00 | 0.36 |
| May | 0.00 | 0.150467E+10 | 0.00 | 0.00 | 58517697.51 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.170039E+10 | 0.00 | 0.00 | 24602593.08 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.210935E+10 | 0.00 | 0.00 | 27370169.08 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.185377E+10 | 0.00 | 0.00 | 53571482.90 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 57262.08 | 0.155857E+10 | 0.00 | 621.90 | 93221187.18 | 0.00 | 1740.89 | 0.00 | 0.36 |
| October | 23894101.92 | 0.115689E+10 | 0.00 | 1289428.12 | 56471913.51 | 0.00 | 47758264.82 | 0.00 | 0.36 |
| November | 62892701.11 | 0.322783E+09 | 0.00 | 6232953.44 | 44512753.19 | 0.00 | 0.203420E+09 | 0.00 | 0.35 |
| December | 0.174051E+09 | 0.182761E+09 | 0.00 | 4969048.75 | 46415746.57 | 0.00 | 0.285455E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.948297E+09 | 0.111135E+11 | 0.00 | 27225683.45 | 0.555944E+09 | 0.00 | 0.126273E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 70697131.57 | 0.00 | 0.00 | 20361794.08 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.276984E+09 | 0.210935E+10 | 0.00 | 6232953.44 | 93221187.18 | 0.00 | 0.286656E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.471791E+09 | 46998006.91 | 0.00 | 671204.69 | 17443699.94 | 0.00 | 77921737.02 | 0.00 | 0.35 |
| February | 0.266179E+09 | 68798337.09 | 0.00 | 1109869.05 | 25565807.66 | 0.00 | 0.101962E+09 | 0.00 | 0.35 |
| March | 0.235218E+09 | 0.147790E+09 | 0.00 | 1676432.79 | 34499536.61 | 0.00 | 0.124017E+09 | 0.00 | 0.35 |
| April | 59255679.11 | 0.371266E+09 | 0.00 | 2097884.15 | 60101928.18 | 0.00 | 74083632.76 | 0.00 | 0.36 |
| May | 0.00 | 0.150142E+10 | 0.00 | 0.00 | 58315198.31 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.170661E+10 | 0.00 | 0.00 | 23434266.51 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.211122E+10 | 0.00 | 0.00 | 26750674.32 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.183385E+10 | 0.00 | 0.00 | 52266129.99 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 112099.02 | 0.150825E+10 | 0.00 | 401.81 | 87238360.96 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 25067650.88 | 0.107793E+10 | 0.00 | 740519.13 | 57738653.54 | 0.00 | 49069043.01 | 0.00 | 0.36 |
| November | 0.109937E+09 | 0.276469E+09 | 0.00 | 1983983.17 | 43613712.00 | 0.00 | 0.170455E+09 | 0.00 | 0.35 |
| December | 0.346371E+09 | 0.148877E+09 | 0.00 | 915667.79 | 41250905.97 | 0.00 | 0.108976E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.151393E+10 | 0.107995E+11 | 0.00 | 9195962.59 | 0.528219E+09 | 0.00 | 0.706484E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 46998006.91 | 0.00 | 0.00 | 17443699.94 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.471791E+09 | 0.211122E+10 | 0.00 | 2097884.15 | 87238360.96 | 0.00 | 0.170455E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.269642E+09 | 69694036.97 | 0.00 | 4737368.04 | 19219670.44 | 0.00 | 0.297299E+09 | 0.00 | 0.35 |
| February | 0.167629E+09 | 98739115.80 | 0.00 | 3451399.91 | 29566814.70 | 0.00 | 0.197788E+09 | 0.00 | 0.35 |
| March | 0.183271E+09 | 0.168731E+09 | 0.00 | 3285046.19 | 36554274.63 | 0.00 | 0.177746E+09 | 0.00 | 0.35 |
| April | 59520168.07 | 0.389824E+09 | 0.00 | 3311311.71 | 58230901.61 | 0.00 | 76499066.39 | 0.00 | 0.36 |
| May | 0.00 | 0.151816E+10 | 0.00 | 0.00 | 55281964.99 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.170921E+10 | 0.00 | 0.00 | 23047448.40 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.212079E+10 | 0.00 | 0.00 | 26181218.37 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.185730E+10 | 0.00 | 0.00 | 50531330.33 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 60288.54 | 0.155812E+10 | 0.00 | 681.05 | 91010226.69 | 0.00 | 1812.65 | 0.00 | 0.36 |
| October | 24243646.02 | 0.115745E+10 | 0.00 | 1255986.58 | 55282826.08 | 0.00 | 48586242.35 | 0.00 | 0.36 |
| November | 65232052.39 | 0.323466E+09 | 0.00 | 6399525.23 | 42328807.31 | 0.00 | 0.204095E+09 | 0.00 | 0.35 |
| December | 0.179475E+09 | 0.179979E+09 | 0.00 | 4785697.27 | 44224384.07 | 0.00 | 0.282383E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.949073E+09 | 0.111515E+11 | 0.00 | 27227015.98 | 0.531460E+09 | 0.00 | 0.128440E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 69694036.97 | 0.00 | 0.00 | 19219670.44 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.269642E+09 | 0.212079E+10 | 0.00 | 6399525.23 | 91010226.69 | 0.00 | 0.297299E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.487283E+09 | 45760737.22 | 0.00 | 601670.43 | 14769326.99 | 0.00 | 66782677.18 | 0.00 | 0.35 |
| February | 0.267716E+09 | 65105967.34 | 0.00 | 1192945.46 | 22679326.96 | 0.00 | 0.105200E+09 | 0.00 | 0.35 |
| March | 0.235207E+09 | 0.152421E+09 | 0.00 | 1605900.79 | 31998562.38 | 0.00 | 0.126366E+09 | 0.00 | 0.35 |
| April | 65381772.05 | 0.375014E+09 | 0.00 | 2186260.01 | 55714526.60 | 0.00 | 75802332.96 | 0.00 | 0.36 |
| May | 0.00 | 0.151822E+10 | 0.00 | 0.00 | 55049702.90 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.171820E+10 | 0.00 | 0.00 | 22086163.84 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.212546E+10 | 0.00 | 0.00 | 25900752.06 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.183977E+10 | 0.00 | 0.00 | 51120595.23 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 110817.89 | 0.151139E+10 | 0.00 | 796.51 | 85804422.56 | 0.00 | 3912.49 | 0.00 | 0.36 |
| October | 25507432.21 | 0.108248E+10 | 0.00 | 707850.30 | 54823777.17 | 0.00 | 50012845.27 | 0.00 | 0.36 |
| November | 0.109352E+09 | 0.276488E+09 | 0.00 | 2071685.85 | 41085845.53 | 0.00 | 0.174623E+09 | 0.00 | 0.35 |
| December | 0.344055E+09 | 0.143520E+09 | 0.00 | 791156.13 | 39930593.03 | 0.00 | 0.110933E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.153461E+10 | 0.108538E+11 | 0.00 | 9158265.47 | 0.500964E+09 | 0.00 | 0.709723E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 45760737.22 | 0.00 | 0.00 | 14769326.99 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.487283E+09 | 0.212546E+10 | 0.00 | 2186260.01 | 85804422.56 | 0.00 | 0.174623E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.391740E+09 | 46237132.82 | 0.00 | 1246057.82 | 15898807.13 | 0.00 | 0.193571E+09 | 0.00 | 0.35 |
| February | 0.205450E+09 | 64237615.96 | 0.00 | 1645295.59 | 23830403.29 | 0.00 | 0.179663E+09 | 0.00 | 0.35 |
| March | 0.166039E+09 | 0.143416E+09 | 0.00 | 2163939.54 | 32857817.63 | 0.00 | 0.203241E+09 | 0.00 | 0.35 |
| April | 59427578.43 | 0.352995E+09 | 0.00 | 2140282.28 | 57771473.68 | 0.00 | 74913568.38 | 0.00 | 0.36 |
| May | 0.00 | 0.145913E+10 | 0.00 | 0.00 | 57870651.20 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.164741E+10 | 0.00 | 0.00 | 24552569.88 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.204701E+10 | 0.00 | 0.00 | 25584971.89 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.177664E+10 | 0.00 | 0.00 | 52251334.89 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 410636.83 | 0.146261E+10 | 0.00 | 11170.69 | 88683735.29 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 24990318.08 | 0.104775E+10 | 0.00 | 824411.65 | 58201439.44 | 0.00 | 50250523.47 | 0.00 | 0.36 |
| November | 79004245.67 | 0.267994E+09 | 0.00 | 2572453.95 | 43204673.47 | 0.00 | 0.203963E+09 | 0.00 | 0.35 |
| December | 0.215026E+09 | 0.144301E+09 | 0.00 | 1620797.67 | 40567304.49 | 0.00 | 0.260667E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.114209E+10 | 0.104597E+11 | 0.00 | 12224409.18 | 0.521275E+09 | 0.00 | 0.116627E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 46237132.82 | 0.00 | 0.00 | 15898807.13 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.391740E+09 | 0.204701E+10 | 0.00 | 2572453.95 | 88683735.29 | 0.00 | 0.260667E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.390653E+09 | 46248286.37 | 0.00 | 1249931.08 | 15777532.17 | 0.00 | 0.194926E+09 | 0.00 | 0.35 |
| February | 0.204878E+09 | 63969752.87 | 0.00 | 1652419.98 | 23785034.99 | 0.00 | 0.180466E+09 | 0.00 | 0.35 |
| March | 0.165221E+09 | 0.143772E+09 | 0.00 | 2162162.64 | 32880067.68 | 0.00 | 0.204209E+09 | 0.00 | 0.35 |
| April | 59484444.70 | 0.352945E+09 | 0.00 | 2149287.78 | 58177888.50 | 0.00 | 74954832.54 | 0.00 | 0.36 |
| May | 0.00 | 0.145989E+10 | 0.00 | 0.00 | 57890567.46 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.164803E+10 | 0.00 | 0.00 | 24548390.02 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.204786E+10 | 0.00 | 0.00 | 25524729.95 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.177704E+10 | 0.00 | 0.00 | 52218931.80 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 410163.93 | 0.146288E+10 | 0.00 | 11164.10 | 88653726.46 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 25012212.35 | 0.104808E+10 | 0.00 | 821586.02 | 58107435.73 | 0.00 | 50281171.73 | 0.00 | 0.36 |
| November | 79106923.91 | 0.267997E+09 | 0.00 | 2574247.27 | 43154256.77 | 0.00 | 0.204032E+09 | 0.00 | 0.35 |
| December | 0.215571E+09 | 0.143965E+09 | 0.00 | 1601433.09 | 40617368.93 | 0.00 | 0.260152E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.114034E+10 | 0.104627E+11 | 0.00 | 12222231.96 | 0.521336E+09 | 0.00 | 0.116902E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 46248286.37 | 0.00 | 0.00 | 15777532.17 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.390653E+09 | 0.204786E+10 | 0.00 | 2574247.27 | 88653726.46 | 0.00 | 0.260152E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.104239E+09 | 72297123.40 | 0.00 | 6480158.87 | 20023883.22 | 0.00 | 0.470982E+09 | 0.00 | 0.35 |
| February | 98193151.19 | 0.101027E+09 | 0.00 | 4388499.46 | 29367211.64 | 0.00 | 0.273593E+09 | 0.00 | 0.35 |
| March | 0.120929E+09 | 0.164497E+09 | 0.00 | 3986359.20 | 36367300.09 | 0.00 | 0.244124E+09 | 0.00 | 0.35 |
| April | 54558634.48 | 0.375318E+09 | 0.00 | 3294147.92 | 58841227.61 | 0.00 | 77911843.12 | 0.00 | 0.36 |
| May | 0.00 | 0.146289E+10 | 0.00 | 0.00 | 57604780.04 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.163913E+10 | 0.00 | 0.00 | 25134369.98 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.204371E+10 | 0.00 | 0.00 | 26363899.56 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.180256E+10 | 0.00 | 0.00 | 52137533.25 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 241170.58 | 0.152513E+10 | 0.00 | 4862.75 | 92159622.77 | 0.00 | 3682.07 | 0.00 | 0.36 |
| October | 23857360.69 | 0.114101E+10 | 0.00 | 1390060.70 | 57085757.59 | 0.00 | 48774551.97 | 0.00 | 0.36 |
| November | 57929294.95 | 0.321636E+09 | 0.00 | 7068067.18 | 43762922.73 | 0.00 | 0.210880E+09 | 0.00 | 0.35 |
| December | 98162515.41 | 0.185058E+09 | 0.00 | 6300601.95 | 44839706.97 | 0.00 | 0.371933E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.558110E+09 | 0.108343E+11 | 0.00 | 32912758.02 | 0.543688E+09 | 0.00 | 0.169820E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 72297123.40 | 0.00 | 0.00 | 20023883.22 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.120929E+09 | 0.204371E+10 | 0.00 | 7068067.18 | 92159622.77 | 0.00 | 0.470982E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.104344E+09 | 72295540.12 | 0.00 | 6482613.39 | 19997498.66 | 0.00 | 0.471014E+09 | 0.00 | 0.35 |
| February | 98202084.23 | 0.101155E+09 | 0.00 | 4391612.32 | 29205347.72 | 0.00 | 0.273592E+09 | 0.00 | 0.35 |
| March | 0.120829E+09 | 0.164838E+09 | 0.00 | 3992668.28 | 36302146.55 | 0.00 | 0.244307E+09 | 0.00 | 0.35 |
| April | 54860790.80 | 0.375699E+09 | 0.00 | 3305262.93 | 58720669.23 | 0.00 | 77716921.19 | 0.00 | 0.36 |
| May | 0.00 | 0.146364E+10 | 0.00 | 0.00 | 57619103.23 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.163979E+10 | 0.00 | 0.00 | 25129462.62 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.204454E+10 | 0.00 | 0.00 | 26348944.76 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.180291E+10 | 0.00 | 0.00 | 52127519.41 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 241582.37 | 0.152532E+10 | 0.00 | 4864.79 | 92142777.58 | 0.00 | 2658.26 | 0.00 | 0.36 |
| October | 23841081.73 | 0.114144E+10 | 0.00 | 1387152.03 | 56925168.70 | 0.00 | 48808905.03 | 0.00 | 0.36 |
| November | 57968230.31 | 0.321711E+09 | 0.00 | 7077519.49 | 43782321.13 | 0.00 | 0.210863E+09 | 0.00 | 0.35 |
| December | 98466003.47 | 0.184902E+09 | 0.00 | 6293265.40 | 44822167.38 | 0.00 | 0.371738E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.558752E+09 | 0.108382E+11 | 0.00 | 32934958.63 | 0.543123E+09 | 0.00 | 0.169804E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 72295540.12 | 0.00 | 0.00 | 19997498.66 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.120829E+09 | 0.204454E+10 | 0.00 | 7077519.49 | 92142777.58 | 0.00 | 0.471014E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.146794E+09 | 29344278.63 | 0.00 | 1518844.07 | 9428846.82 | 59754721.13 | 49638152.64 | 0.00 | 0.35 |
| February | 0.107850E+09 | 42865875.67 | 0.00 | 1009898.52 | 13837892.18 | 33792237.64 | 37672217.80 | 0.00 | 0.35 |
| March | 0.105640E+09 | 75377044.83 | 0.00 | 1095116.86 | 17815947.01 | 32239226.92 | 31685776.73 | 0.00 | 0.35 |
| April | 48436436.52 | 0.183967E+09 | 0.00 | 1398011.74 | 28726496.04 | 0.00 | 21140275.24 | 0.00 | 0.36 |
| May | 0.00 | 0.744984E+09 | 0.00 | 0.00 | 26520169.35 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.849745E+09 | 0.00 | 0.00 | 10527651.85 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.105477E+10 | 0.00 | 0.00 | 13393390.21 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.921609E+09 | 0.00 | 934.32 | 24660171.22 | 0.00 | 5244.50 | 0.00 | 0.36 |
| September | 0.00 | 0.763962E+09 | 0.00 | 0.00 | 43372959.52 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 23425947.49 | 0.565612E+09 | 0.00 | 459198.85 | 24337105.00 | 0.00 | 14422312.05 | 0.00 | 0.36 |
| November | 94570668.14 | 0.152029E+09 | 0.00 | 2329384.51 | 19924558.66 | 746112.14 | 43214242.29 | 0.00 | 0.35 |
| December | 0.133016E+09 | 81887949.91 | 0.00 | 1605146.84 | 21685586.00 | 35780756.22 | 40998420.11 | 0.00 | 0.35 |
| Annual Sum or Average | 0.659732E+09 | 0.546615E+10 | 0.00 | 9416535.70 | 0.254231E+09 | 0.162313E+09 | 0.238777E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 29344278.63 | 0.00 | 0.00 | 9428846.82 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.146794E+09 | 0.105477E+10 | 0.00 | 2329384.51 | 43372959.52 | 59754721.13 | 49638152.64 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.113622E+09 | 20104030.49 | 1042.09 | 134177.95 | 9087562.09 | 0.116205E+09 | 8721633.82 | 187.08 | 0.35 |
| February | 0.100778E+09 | 29472764.10 | 0.00 | 256700.49 | 11606517.97 | 56521690.49 | 16187703.84 | 0.00 | 0.35 |
| March | 0.106368E+09 | 68205013.56 | 0.00 | 409789.64 | 16511430.57 | 42228863.36 | 18659022.13 | 0.00 | 0.35 |
| April | 53818288.87 | 0.177429E+09 | 0.00 | 803337.99 | 27905125.40 | 0.00 | 19271471.00 | 0.00 | 0.36 |
| May | 0.00 | 0.745863E+09 | 0.00 | 0.00 | 25786487.90 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.854046E+09 | 0.00 | 0.00 | 9656148.53 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.105720E+10 | 0.00 | 0.00 | 13232574.23 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.914331E+09 | 0.00 | 1385.86 | 24482243.13 | 0.00 | 7257.98 | 0.00 | 0.36 |
| September | 103238.33 | 0.743763E+09 | 0.00 | 1597.40 | 41123388.06 | 0.00 | 441.98 | 0.00 | 0.36 |
| October | 27113024.66 | 0.531997E+09 | 0.00 | 216009.38 | 24868186.84 | 0.00 | 10573675.38 | 0.00 | 0.36 |
| November | 0.114331E+09 | 0.130878E+09 | 0.00 | 407031.55 | 20389430.18 | 3431818.82 | 17776322.54 | 0.00 | 0.35 |
| December | 0.115191E+09 | 66121867.21 | 418812.20 | 120430.71 | 20185806.79 | 71816967.16 | 8802717.01 | 4319.96 | 0.35 |
| Annual Sum or Average | 0.631324E+09 | 0.533941E+10 | 419854.29 | 2350460.96 | 0.244835E+09 | 0.290205E+09 | 0.100000E+09 | 4507.04 | 0.36 |
| Minimum of Months | 0.00 | 20104030.49 | 0.00 | 0.00 | 9087562.09 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.115191E+09 | 0.105720E+10 | 418812.20 | 803337.99 | 41123388.06 | 0.116205E+09 | 19271471.00 | 4319.96 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.151140E+09 | 28980088.40 | 0.00 | 1400642.74 | 8519925.63 | 56358727.61 | 50911483.72 | 0.00 | 0.35 |
| February | 0.110931E+09 | 42488000.55 | 0.00 | 1008908.22 | 13113663.92 | 31684695.28 | 39124357.53 | 0.00 | 0.35 |
| March | 0.110798E+09 | 77057409.69 | 0.00 | 1036719.77 | 17057621.47 | 31371831.98 | 30871742.41 | 0.00 | 0.35 |
| April | 51084221.05 | 0.184579E+09 | 0.00 | 1463956.85 | 26616341.24 | 0.00 | 22503213.06 | 0.00 | 0.36 |
| May | 0.00 | 0.753108E+09 | 0.00 | 0.00 | 24211651.63 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.855093E+09 | 0.00 | 0.00 | 9624130.74 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.106026E+10 | 0.00 | 0.00 | 13774916.55 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.924797E+09 | 0.00 | 940.47 | 23155239.27 | 0.00 | 4979.58 | 0.00 | 0.36 |
| September | 0.00 | 0.765170E+09 | 0.00 | 0.00 | 42553701.02 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 24761477.86 | 0.567172E+09 | 0.00 | 435072.81 | 23199676.35 | 0.00 | 13941125.34 | 0.00 | 0.36 |
| November | 93782446.00 | 0.152604E+09 | 0.00 | 2365454.19 | 18615156.97 | 949154.77 | 46041721.20 | 0.00 | 0.35 |
| December | 0.133275E+09 | 80931191.36 | 0.00 | 1492861.94 | 20354998.88 | 36374590.90 | 41012005.37 | 0.00 | 0.35 |
| Annual Sum or Average | 0.675772E+09 | 0.549224E+10 | 0.00 | 9204557.00 | 0.240797E+09 | 0.156739E+09 | 0.244411E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 28980088.40 | 0.00 | 0.00 | 8519925.63 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.151140E+09 | 0.106026E+10 | 0.00 | 2365454.19 | 42553701.02 | 56358727.61 | 50911483.72 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.119710E+09 | 19586002.17 | 0.00 | 118348.71 | 7627717.75 | 0.110338E+09 | 8408014.88 | 0.00 | 0.35 |
| February | 0.105990E+09 | 29122855.35 | 0.00 | 240690.10 | 10058064.27 | 54752113.40 | 16402822.78 | 0.00 | 0.35 |
| March | 0.107816E+09 | 70196981.83 | 0.00 | 360126.44 | 15248347.84 | 41352397.16 | 18147707.60 | 0.00 | 0.35 |
| April | 56917508.01 | 0.178466E+09 | 0.00 | 821669.89 | 25701779.73 | 0.00 | 19939121.45 | 0.00 | 0.36 |
| May | 0.00 | 0.753502E+09 | 0.00 | 0.00 | 24018380.17 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.858819E+09 | 0.00 | 0.00 | 9116479.12 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.106257E+10 | 0.00 | 0.00 | 13336916.24 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.917782E+09 | 0.00 | 1395.69 | 23012942.67 | 0.00 | 6691.21 | 0.00 | 0.36 |
| September | 115737.62 | 0.745512E+09 | 0.00 | 2401.33 | 40027455.11 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 28488906.59 | 0.534138E+09 | 0.00 | 194943.04 | 23205641.10 | 0.00 | 9937095.79 | 0.00 | 0.36 |
| November | 0.116941E+09 | 0.131346E+09 | 0.00 | 399994.77 | 18063081.88 | 3114604.95 | 17182450.70 | 0.00 | 0.35 |
| December | 0.116914E+09 | 64849338.57 | 154346.87 | 82244.73 | 18013693.83 | 71882540.76 | 5852332.02 | 976.24 | 0.35 |
| Annual Sum or Average | 0.652893E+09 | 0.536589E+10 | 154346.87 | 2221814.69 | 0.227430E+09 | 0.281440E+09 | 95876236.43 | 976.24 | 0.36 |
| Minimum of Months | 0.00 | 19586002.17 | 0.00 | 0.00 | 7627717.75 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.119710E+09 | 0.106257E+10 | 154346.87 | 821669.89 | 40027455.11 | 0.110338E+09 | 19939121.45 | 976.24 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.149095E+09 | 20095079.20 | 0.00 | 171464.23 | 7905375.15 | 80347209.85 | 15718556.68 | 0.00 | 0.35 |
| February | 0.117314E+09 | 28436560.96 | 0.00 | 326743.36 | 10293508.02 | 38777927.82 | 22835458.74 | 0.00 | 0.35 |
| March | 0.115379E+09 | 68186995.26 | 0.00 | 412916.20 | 15526746.47 | 27806744.19 | 27572624.86 | 0.00 | 0.35 |
| April | 46183127.01 | 0.173656E+09 | 0.00 | 796533.17 | 26766505.22 | 0.00 | 27305760.01 | 0.00 | 0.36 |
| May | 0.00 | 0.737056E+09 | 0.00 | 0.00 | 26384367.33 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.838387E+09 | 0.00 | 0.00 | 9754783.11 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.104034E+10 | 0.00 | 0.00 | 13180550.48 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.901072E+09 | 0.00 | 1444.81 | 24494717.41 | 0.00 | 6308.23 | 0.00 | 0.36 |
| September | 98158.84 | 0.735654E+09 | 0.00 | 1726.44 | 40824285.29 | 0.00 | 278.82 | 0.00 | 0.36 |
| October | 22185189.15 | 0.525923E+09 | 0.00 | 233349.55 | 25501655.98 | 0.00 | 16560212.36 | 0.00 | 0.36 |
| November | 0.114854E+09 | 0.128803E+09 | 0.00 | 468252.10 | 19572032.10 | 0.00 | 26049491.54 | 0.00 | 0.35 |
| December | 0.151017E+09 | 66509405.79 | 6646.49 | 121782.59 | 19279828.77 | 41394661.29 | 12563902.25 | 18.46 | 0.35 |
| Annual Sum or Average | 0.716126E+09 | 0.526412E+10 | 6646.49 | 2534212.47 | 0.239484E+09 | 0.188327E+09 | 0.148613E+09 | 18.46 | 0.36 |
| Minimum of Months | 0.00 | 20095079.20 | 0.00 | 0.00 | 7905375.15 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.151017E+09 | 0.104034E+10 | 6646.49 | 796533.17 | 40824285.29 | 80347209.85 | 27572624.86 | 18.46 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.149358E+09 | 20126896.45 | 0.00 | 171262.84 | 7764566.99 | 80313973.05 | 15512180.05 | 0.00 | 0.35 |
| February | 0.117085E+09 | 28497413.51 | 0.00 | 325232.76 | 10190838.24 | 38836848.10 | 23274484.00 | 0.00 | 0.35 |
| March | 0.115165E+09 | 68416104.43 | 0.00 | 412424.28 | 15503612.37 | 27751904.09 | 27892949.33 | 0.00 | 0.35 |
| April | 46546380.65 | 0.173854E+09 | 0.00 | 799482.19 | 26731474.73 | 0.00 | 27183176.09 | 0.00 | 0.36 |
| May | 0.00 | 0.737809E+09 | 0.00 | 0.00 | 26159782.34 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.838817E+09 | 0.00 | 0.00 | 9766425.13 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.104090E+10 | 0.00 | 0.00 | 13161508.16 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.901439E+09 | 0.00 | 1431.73 | 24443866.83 | 0.00 | 6060.96 | 0.00 | 0.36 |
| September | 95607.91 | 0.735943E+09 | 0.00 | 1729.96 | 40783645.29 | 0.00 | 272.96 | 0.00 | 0.36 |
| October | 22167526.94 | 0.526246E+09 | 0.00 | 229226.20 | 25421712.50 | 0.00 | 16624544.87 | 0.00 | 0.36 |
| November | 0.114873E+09 | 0.128940E+09 | 0.00 | 469859.81 | 19503661.92 | 0.00 | 26129030.60 | 0.00 | 0.35 |
| December | 0.151111E+09 | 66475617.78 | 6663.61 | 117634.00 | 19203943.04 | 41565999.84 | 12137012.50 | 19.71 | 0.35 |
| Annual Sum or Average | 0.716402E+09 | 0.526746E+10 | 6663.61 | 2528283.77 | 0.238635E+09 | 0.188469E+09 | 0.148760E+09 | 19.71 | 0.36 |
| Minimum of Months | 0.00 | 20126896.45 | 0.00 | 0.00 | 7764566.99 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.151111E+09 | 0.104090E+10 | 6663.61 | 799482.19 | 40783645.29 | 80313973.05 | 27892949.33 | 19.71 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.183389E+09 | 30782007.30 | 0.00 | 1674567.71 | 8921209.57 | 15760515.27 | 70048121.41 | 0.00 | 0.35 |
| February | 0.109556E+09 | 44103750.25 | 0.00 | 1171945.24 | 13341031.27 | 17793737.45 | 58538241.66 | 0.00 | 0.35 |
| March | 0.111617E+09 | 76809737.87 | 0.00 | 1137054.13 | 17170406.80 | 18256477.16 | 45110394.13 | 0.00 | 0.35 |
| April | 39533954.64 | 0.181654E+09 | 0.00 | 1392338.95 | 27751679.08 | 0.00 | 31098342.38 | 0.00 | 0.36 |
| May | 0.00 | 0.736167E+09 | 0.00 | 0.00 | 26992426.62 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.832859E+09 | 0.00 | 0.00 | 10946824.10 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.103746E+10 | 0.00 | 0.00 | 13443111.85 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.910003E+09 | 0.00 | 976.95 | 24726668.65 | 0.00 | 4498.78 | 0.00 | 0.36 |
| September | 9.03 | 0.760370E+09 | 0.00 | 0.00 | 43567728.55 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 17414461.96 | 0.565674E+09 | 0.00 | 516081.62 | 24968717.98 | 0.00 | 21219493.93 | 0.00 | 0.36 |
| November | 76344316.54 | 0.153159E+09 | 0.00 | 2636474.14 | 19675393.04 | 0.00 | 65813491.31 | 0.00 | 0.35 |
| December | 0.142465E+09 | 84602310.45 | 0.00 | 1803648.41 | 20963168.69 | 17695594.14 | 62009449.42 | 0.00 | 0.35 |
| Annual Sum or Average | 0.680320E+09 | 0.541364E+10 | 0.00 | 10333087.15 | 0.252468E+09 | 69506324.02 | 0.353842E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 30782007.30 | 0.00 | 0.00 | 8921209.57 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.183389E+09 | 0.103746E+10 | 0.00 | 2636474.14 | 43567728.55 | 18256477.16 | 70048121.41 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.182981E+09 | 30764567.65 | 0.00 | 1684879.13 | 8894155.96 | 15759529.52 | 70567337.96 | 0.00 | 0.35 |
| February | 0.109474E+09 | 44119160.22 | 0.00 | 1177008.42 | 13314697.34 | 17905409.49 | 58608055.34 | 0.00 | 0.35 |
| March | 0.111740E+09 | 76883797.90 | 0.00 | 1148149.00 | 17144925.37 | 18255898.15 | 45569577.79 | 0.00 | 0.35 |
| April | 39616495.37 | 0.181875E+09 | 0.00 | 1399895.98 | 27651066.23 | 0.00 | 31102297.02 | 0.00 | 0.36 |
| May | 0.00 | 0.736735E+09 | 0.00 | 0.00 | 26953085.96 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.833338E+09 | 0.00 | 0.00 | 10922763.41 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.103798E+10 | 0.00 | 0.00 | 13440827.62 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.910189E+09 | 0.00 | 977.75 | 24687916.27 | 0.00 | 4331.94 | 0.00 | 0.36 |
| September | 0.00 | 0.760547E+09 | 0.00 | 0.00 | 43614937.22 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 17389458.88 | 0.565878E+09 | 0.00 | 514516.09 | 24980590.54 | 0.00 | 21279143.46 | 0.00 | 0.36 |
| November | 76327442.90 | 0.153296E+09 | 0.00 | 2642746.66 | 19622451.59 | 0.00 | 65831617.28 | 0.00 | 0.35 |
| December | 0.142444E+09 | 84510657.59 | 0.00 | 1800881.41 | 20989453.94 | 17691710.50 | 62040628.79 | 0.00 | 0.35 |
| Annual Sum or Average | 0.679972E+09 | 0.541612E+10 | 0.00 | 10369054.46 | 0.252217E+09 | 69612547.65 | 0.355003E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 30764567.65 | 0.00 | 0.00 | 8894155.96 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.182981E+09 | 0.103798E+10 | 0.00 | 2642746.66 | 43614937.22 | 18255898.15 | 70567337.96 | 0.00 | 0.36 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
| January | 0.125185E+12 | 0.783797E+10 | 0.00 | 0.127096E+10 | 0.310472E+11 |
| February | 0.127374E+12 | 0.659322E+10 | 0.00 | 0.876285E+09 | 0.365469E+11 |
| March | 0.133889E+12 | 0.674584E+10 | 0.00 | 0.806028E+09 | 0.457344E+11 |
| April | 0.141630E+12 | 0.355742E+10 | 0.00 | 0.353146E+09 | 0.767951E+11 |
| May | 0.138857E+12 | -0.327662E+10 | 0.00 | -604257431.8 | 0.153314E+12 |
| June | 0.135507E+12 | -0.261312E+10 | 0.00 | -763773182.6 | 0.159398E+12 |
| July | 0.142493E+12 | -0.368577E+10 | 0.00 | -898856755.2 | 0.176429E+12 |
| August | 0.134889E+12 | -0.410360E+10 | 0.00 | -913955928.4 | 0.173008E+12 |
| September | 0.119990E+12 | -0.375060E+10 | 0.00 | -656878608.3 | 0.153963E+12 |
| October | 0.129964E+12 | -531964837.5 | 0.00 | -194374618.7 | 0.136046E+12 |
| November | 0.107193E+12 | 0.534895E+10 | 0.00 | 0.632374E+09 | 0.668014E+11 |
| December | 0.113509E+12 | 0.688855E+10 | 0.00 | 0.102669E+10 | 0.468088E+11 |
| Annual Sum or Average | 0.155048E+13 | 0.190103E+11 | 0.00 | 0.933384E+09 | 0.125589E+13 |
| Minimum of Months | 0.107193E+12 | -0.410360E+10 | 0.00 | -913955928.4 | 0.310472E+11 |
| Maximum of Months | 0.142493E+12 | 0.783797E+10 | 0.00 | 0.127096E+10 | 0.176429E+12 |