Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2024.07.03 12:21
Tabular Output Report in Format: HTML
Building: ApartmentMidRise
Environment: RUNPERIOD 1 ** New Delhi-Safdarjung AP Delhi IND IWEC2 WMO#=421820
Simulation Timestamp: 2024-07-03 12:21:22
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Values gathered over 8760.00 hours| Total Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
| Total Site Energy | 1373.95 | 438.32 | 486.53 |
| Net Site Energy | 1373.95 | 438.32 | 486.53 |
| Total Source Energy | 3675.41 | 1172.52 | 1301.50 |
| Net Source Energy | 3675.41 | 1172.52 | 1301.50 |
| Site=>Source Conversion Factor | |
| Electricity | 3.167 |
| Natural Gas | 1.084 |
| District Cooling | 1.056 |
| District Heating | 3.613 |
| Steam | 1.200 |
| Gasoline | 1.050 |
| Diesel | 1.050 |
| Coal | 1.050 |
| Fuel Oil No 1 | 1.050 |
| Fuel Oil No 2 | 1.050 |
| Propane | 1.050 |
| Other Fuel 1 | 1.000 |
| Other Fuel 2 | 1.000 |
| Area [m2] | |
| Total Building Area | 3134.61 |
| Net Conditioned Building Area | 2823.98 |
| Unconditioned Building Area | 310.64 |
| Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | 0.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 343.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 73.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 33.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 454.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 144.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 324.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.51 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 1049.47 | 324.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.51 |
| Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | General | 0.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | General | 343.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | LightsWired | 67.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| LightsPlugIn | 5.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | General | 33.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | ElevatorLift | 67.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| ElevatorLightsFan | 0.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| MiscPlug | 386.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| General | 144.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Pumps | General | 0.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.51 | |
| Water Heater | 0.00 | 324.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | Unassigned | 0.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | Unassigned | 343.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | GENERAL | 73.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | Unassigned | 33.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | GENERAL | 454.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Unassigned | 144.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | Unassigned | 0.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Unassigned | 0.00 | 324.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1875.51 |
| Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 37.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 173.31 | 114.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| Other | 160.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 371.63 | 114.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 33.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 156.14 | 103.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| Other | 144.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 334.80 | 103.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 |
| Electricity [GJ] | Percent Electricity [%] | |
| Fuel-Fired Power Generation | 0.000 | 0.00 |
| High Temperature Geothermal* | 0.000 | 0.00 |
| Photovoltaic Power | 0.000 | 0.00 |
| Wind Power | 0.000 | 0.00 |
| Power Conversion | 0.000 | 0.00 |
| Net Decrease in On-Site Storage | 0.000 | 0.00 |
| Total On-Site Electric Sources | 0.000 | 0.00 |
| Electricity Coming From Utility | 1049.470 | 100.00 |
| Surplus Electricity Going To Utility | 0.000 | 0.00 |
| Net Electricity From Utility | 1049.470 | 100.00 |
| Total On-Site and Utility Electric Sources | 1049.470 | 100.00 |
| Total Electricity End Uses | 1049.470 | 100.00 |
| Heat [GJ] | Percent Heat [%] | |
| Water-Side Heat Recovery | 0.00 | 0.00 |
| Air to Air Heat Recovery for Cooling | 170.27 | 71.37 |
| Air to Air Heat Recovery for Heating | 68.30 | 28.63 |
| High-Temperature Geothermal* | 0.00 | 0.00 |
| Solar Water Thermal | 0.00 | 0.00 |
| Solar Air Thermal | 0.00 | 0.00 |
| Total On-Site Thermal Sources | 238.57 | 100.00 |
| Water [m3] | Percent Water [%] | |
| Rainwater Collection | 0.00 | 0.00 |
| Condensate Collection | 0.00 | 0.00 |
| Groundwater Well | 0.00 | 0.00 |
| Total On Site Water Sources | 0.00 | 0.00 |
| - | - | - |
| Initial Storage | 0.00 | 0.00 |
| Final Storage | 0.00 | 0.00 |
| Change in Storage | 0.00 | 0.00 |
| - | - | - |
| Water Supplied by Utility | 1875.51 | 100.00 |
| - | - | - |
| Total On Site, Change in Storage, and Utility Water Sources | 1875.51 | 100.00 |
| Total Water End Uses | 1875.51 | 100.00 |
| Degrees [deltaC] | |
| Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
| Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
| Facility [Hours] | |
| Time Setpoint Not Met During Occupied Heating | 0.00 |
| Time Setpoint Not Met During Occupied Cooling | 0.00 |
| Time Not Comfortable Based on Simple ASHRAE 55-2004 | 8760.00 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 1B
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2019
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY IND_DELHI_NEWDELHI
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PERFORMANCEPATHPROPOSED
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |ZoneCoolingSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ZoneHeatingSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ZoneElectricSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |SpaceGainsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |PeakSpaceGainsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |SpaceGainComponentsAtCoolingPeakMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |ComfortReportSimple55Monthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |OccupantComfortDataSummaryMonthly
| OCCUP_GSW | OCCUP_GNW | OCCUP_OFFICE | OCCUP_GNE | OCCUP_GN1 | OCCUP_GN2 | OCCUP_GS1 | OCCUP_GS2 | OCCUP_MSW | OCCUP_MNW | OCCUP_MSE | OCCUP_MNE | OCCUP_MN1 | OCCUP_MN2 | OCCUP_MS1 | OCCUP_MS2 | OCCUP_TSW | OCCUP_TNW | OCCUP_TSE | OCCUP_TNE | OCCUP_TN1 | OCCUP_TN2 | OCCUP_TS1 | OCCUP_TS2 | OCCUP_T CORRIDOR | OCCUP_G CORRIDOR | OCCUP_M CORRIDOR |DXReportMonthly
| SPLIT GSW HP COOLING COIL | SPLIT GNW HP COOLING COIL | SPLIT OFFICE HP COOLING COIL | SPLIT GNE HP COOLING COIL | SPLIT GN1 HP COOLING COIL | SPLIT GN2 HP COOLING COIL | SPLIT GS1 HP COOLING COIL | SPLIT GS2 HP COOLING COIL | SPLIT MSW HP COOLING COIL | SPLIT MNW HP COOLING COIL | SPLIT MSE HP COOLING COIL | SPLIT MNE HP COOLING COIL | SPLIT MN1 HP COOLING COIL | SPLIT MN2 HP COOLING COIL | SPLIT MS1 HP COOLING COIL | SPLIT MS2 HP COOLING COIL | SPLIT TSW HP COOLING COIL | SPLIT TNW HP COOLING COIL | SPLIT TSE HP COOLING COIL | SPLIT TNE HP COOLING COIL | SPLIT TN1 HP COOLING COIL | SPLIT TN2 HP COOLING COIL | SPLIT TS1 HP COOLING COIL | SPLIT TS2 HP COOLING COIL |WindowReportMonthly
| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |WindowEnergyReportMonthly
| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |WindowZoneSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |WindowEnergyZoneSummaryMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| SWHSYS1 WATER HEATER |DaylightingReportMonthly
| Environment |CoilReportMonthly
| SPLIT GSW HEATING COIL | SPLIT GNW HEATING COIL | SPLIT OFFICE HEATING COIL | SPLIT GNE HEATING COIL | SPLIT GN1 HEATING COIL | SPLIT GN2 HEATING COIL | SPLIT GS1 HEATING COIL | SPLIT GS2 HEATING COIL | SPLIT MSW HEATING COIL | SPLIT MNW HEATING COIL | SPLIT MSE HEATING COIL | SPLIT MNE HEATING COIL | SPLIT MN1 HEATING COIL | SPLIT MN2 HEATING COIL | SPLIT MS1 HEATING COIL | SPLIT MS2 HEATING COIL | SPLIT TSW HEATING COIL | SPLIT TNW HEATING COIL | SPLIT TSE HEATING COIL | SPLIT TNE HEATING COIL | SPLIT TN1 HEATING COIL | SPLIT TN2 HEATING COIL | SPLIT TS1 HEATING COIL | SPLIT TS2 HEATING COIL | SPLIT GSW_SUPPHEATCOIL | SPLIT GNW_SUPPHEATCOIL | SPLIT OFFICE_SUPPHEATCOIL | SPLIT GNE_SUPPHEATCOIL | SPLIT GN1_SUPPHEATCOIL | SPLIT GN2_SUPPHEATCOIL | SPLIT GS1_SUPPHEATCOIL | SPLIT GS2_SUPPHEATCOIL | SPLIT MSW_SUPPHEATCOIL | SPLIT MNW_SUPPHEATCOIL | SPLIT MSE_SUPPHEATCOIL | SPLIT MNE_SUPPHEATCOIL | SPLIT MN1_SUPPHEATCOIL | SPLIT MN2_SUPPHEATCOIL | SPLIT MS1_SUPPHEATCOIL | SPLIT MS2_SUPPHEATCOIL | SPLIT TSW_SUPPHEATCOIL | SPLIT TNW_SUPPHEATCOIL | SPLIT TSE_SUPPHEATCOIL | SPLIT TNE_SUPPHEATCOIL | SPLIT TN1_SUPPHEATCOIL | SPLIT TN2_SUPPHEATCOIL | SPLIT TS1_SUPPHEATCOIL | SPLIT TS2_SUPPHEATCOIL | SPLIT GSW HP COOLING COIL | SPLIT GNW HP COOLING COIL | SPLIT OFFICE HP COOLING COIL | SPLIT GNE HP COOLING COIL | SPLIT GN1 HP COOLING COIL | SPLIT GN2 HP COOLING COIL | SPLIT GS1 HP COOLING COIL | SPLIT GS2 HP COOLING COIL | SPLIT MSW HP COOLING COIL | SPLIT MNW HP COOLING COIL | SPLIT MSE HP COOLING COIL | SPLIT MNE HP COOLING COIL | SPLIT MN1 HP COOLING COIL | SPLIT MN2 HP COOLING COIL | SPLIT MS1 HP COOLING COIL | SPLIT MS2 HP COOLING COIL | SPLIT TSW HP COOLING COIL | SPLIT TNW HP COOLING COIL | SPLIT TSE HP COOLING COIL | SPLIT TNE HP COOLING COIL | SPLIT TN1 HP COOLING COIL | SPLIT TN2 HP COOLING COIL | SPLIT TS1 HP COOLING COIL | SPLIT TS2 HP COOLING COIL |PlantLoopDemandReportMonthly
| SWHSYS1 |FanReportMonthly
| SPLIT GSW SUPPLY FAN | G SW APARTMENT ERV SUP FAN | G SW APARTMENT ERV EXH FAN | SPLIT GNW SUPPLY FAN | G NW APARTMENT ERV SUP FAN | G NW APARTMENT ERV EXH FAN | SPLIT OFFICE SUPPLY FAN | SPLIT GNE SUPPLY FAN | G NE APARTMENT ERV SUP FAN | G NE APARTMENT ERV EXH FAN | SPLIT GN1 SUPPLY FAN | G N1 APARTMENT ERV SUP FAN | G N1 APARTMENT ERV EXH FAN | SPLIT GN2 SUPPLY FAN | G N2 APARTMENT ERV SUP FAN | G N2 APARTMENT ERV EXH FAN | SPLIT GS1 SUPPLY FAN | G S1 APARTMENT ERV SUP FAN | G S1 APARTMENT ERV EXH FAN | SPLIT GS2 SUPPLY FAN | G S2 APARTMENT ERV SUP FAN | G S2 APARTMENT ERV EXH FAN | SPLIT MSW SUPPLY FAN | M SW APARTMENT ERV SUP FAN | M SW APARTMENT ERV EXH FAN | SPLIT MNW SUPPLY FAN | M NW APARTMENT ERV SUP FAN | M NW APARTMENT ERV EXH FAN | SPLIT MSE SUPPLY FAN | M SE APARTMENT ERV SUP FAN | M SE APARTMENT ERV EXH FAN | SPLIT MNE SUPPLY FAN | M NE APARTMENT ERV SUP FAN | M NE APARTMENT ERV EXH FAN | SPLIT MN1 SUPPLY FAN | M N1 APARTMENT ERV SUP FAN | M N1 APARTMENT ERV EXH FAN | SPLIT MN2 SUPPLY FAN | M N2 APARTMENT ERV SUP FAN | M N2 APARTMENT ERV EXH FAN | SPLIT MS1 SUPPLY FAN | M S1 APARTMENT ERV SUP FAN | M S1 APARTMENT ERV EXH FAN | SPLIT MS2 SUPPLY FAN | M S2 APARTMENT ERV SUP FAN | M S2 APARTMENT ERV EXH FAN | SPLIT TSW SUPPLY FAN | T SW APARTMENT ERV SUP FAN | T SW APARTMENT ERV EXH FAN | SPLIT TNW SUPPLY FAN | T NW APARTMENT ERV SUP FAN | T NW APARTMENT ERV EXH FAN | SPLIT TSE SUPPLY FAN | T SE APARTMENT ERV SUP FAN | T SE APARTMENT ERV EXH FAN | SPLIT TNE SUPPLY FAN | T NE APARTMENT ERV SUP FAN | T NE APARTMENT ERV EXH FAN | SPLIT TN1 SUPPLY FAN | T N1 APARTMENT ERV SUP FAN | T N1 APARTMENT ERV EXH FAN | SPLIT TN2 SUPPLY FAN | T N2 APARTMENT ERV SUP FAN | T N2 APARTMENT ERV EXH FAN | SPLIT TS1 SUPPLY FAN | T S1 APARTMENT ERV SUP FAN | T S1 APARTMENT ERV EXH FAN | SPLIT TS2 SUPPLY FAN | T S2 APARTMENT ERV SUP FAN | T S2 APARTMENT ERV EXH FAN |PumpReportMonthly
| SWHSYS1 PUMP |CondLoopDemandReportMonthly
| SWHSYS1 |ZoneTemperatureOscillationReportMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |AirLoopSystemEnergyAndWaterUseMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |AirLoopSystemComponentLoadsMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |AirLoopSystemComponentEnergyUseMonthly
| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |MechanicalVentilationLoadsMonthly
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
General| Value | |
| Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2024.07.03 12:21 |
| RunPeriod | RUNPERIOD 1 |
| Weather File | New Delhi-Safdarjung AP Delhi IND IWEC2 WMO#=421820 |
| Latitude [deg] | 28.58 |
| Longitude [deg] | 77.20 |
| Elevation [m] | 216.00 |
| Time Zone | 5.50 |
| North Axis Angle [deg] | 0.00 |
| Rotation for Appendix G [deg] | 0.00 |
| Hours Simulated [hrs] | 8760.00 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
| Above Ground Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
| Window Opening Area [m2] | 306.92 | 112.97 | 43.82 | 112.97 | 37.16 |
| Gross Window-Wall Ratio [%] | 19.90 | 20.00 | 21.25 | 20.00 | 18.02 |
| Above Ground Window-Wall Ratio [%] | 19.90 | 20.00 | 21.25 | 20.00 | 18.02 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
| Above Ground Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
| Window Opening Area [m2] | 300.26 | 112.97 | 37.16 | 112.97 | 37.16 |
| Gross Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Above Ground Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Total | |
| Gross Roof Area [m2] | 783.65 |
| Skylight Area [m2] | 0.00 |
| Skylight-Roof Ratio [%] | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| G SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| G NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| OFFICE | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 7.4895 | 18.58 | 6.6700 |
| G NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| G N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| G S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| M SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| M NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| M SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| M NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| M N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| M S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| T SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| T NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| T SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| T NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 0.00 | 11.71 | 11.71 | 5.4896 | 35.30 | 6.6700 |
| T N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| T S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 0.00 | 7.06 | 7.06 | 5.4896 | 35.30 | 6.6700 |
| T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 0.00 | 1.11 | 1.11 | 5.2871 | 18.58 | 0.0000 |
| G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 0.00 | 3.32 | 3.32 | 5.2871 | 18.58 | 515.3919 |
| M CORRIDOR | 77.66 | No | Yes | 236.69 | 2.00 | 10.22 | 0.00 | 1.11 | 1.11 | 5.2871 | 18.58 | 0.0000 |
| Total | 3134.61 | 9553.84 | 1542.04 | 0.00 | 306.92 | 306.92 | 5.5258 | 31.67 | 18.7777 | |||
| Conditioned Total | 2823.98 | 8607.06 | 1501.17 | 0.00 | 300.26 | 300.26 | 5.5521 | 34.33 | 6.6700 | |||
| Unconditioned Total | 310.64 | 946.78 | 40.87 | 0.00 | 6.66 | 6.66 | 5.2871 | 18.58 | 128.8480 | |||
| Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
| G SW APARTMENT | 88.25 | Yes | Yes | 1.00 | G SW APARTMENT | GENERAL | G SW APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| G NW APARTMENT | 88.25 | Yes | Yes | 1.00 | G NW APARTMENT | GENERAL | G NW APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| OFFICE | 88.25 | Yes | Yes | 1.00 | OFFICE | GENERAL | OFFICE | 7.4895 | 18.58 | 6.6700 | |
| G NE APARTMENT | 88.25 | Yes | Yes | 1.00 | G NE APARTMENT | GENERAL | G NE APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| G N1 APARTMENT | 88.25 | Yes | Yes | 1.00 | G N1 APARTMENT | GENERAL | G N1 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| G N2 APARTMENT | 88.25 | Yes | Yes | 1.00 | G N2 APARTMENT | GENERAL | G N2 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| G S1 APARTMENT | 88.25 | Yes | Yes | 1.00 | G S1 APARTMENT | GENERAL | G S1 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| G S2 APARTMENT | 88.25 | Yes | Yes | 1.00 | G S2 APARTMENT | GENERAL | G S2 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M SW APARTMENT | 88.25 | Yes | Yes | 2.00 | M SW APARTMENT | GENERAL | M SW APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M NW APARTMENT | 88.25 | Yes | Yes | 2.00 | M NW APARTMENT | GENERAL | M NW APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M SE APARTMENT | 88.25 | Yes | Yes | 2.00 | M SE APARTMENT | GENERAL | M SE APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M NE APARTMENT | 88.25 | Yes | Yes | 2.00 | M NE APARTMENT | GENERAL | M NE APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M N1 APARTMENT | 88.25 | Yes | Yes | 2.00 | M N1 APARTMENT | GENERAL | M N1 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M N2 APARTMENT | 88.25 | Yes | Yes | 2.00 | M N2 APARTMENT | GENERAL | M N2 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M S1 APARTMENT | 88.25 | Yes | Yes | 2.00 | M S1 APARTMENT | GENERAL | M S1 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| M S2 APARTMENT | 88.25 | Yes | Yes | 2.00 | M S2 APARTMENT | GENERAL | M S2 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T SW APARTMENT | 88.25 | Yes | Yes | 1.00 | T SW APARTMENT | GENERAL | T SW APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T NW APARTMENT | 88.25 | Yes | Yes | 1.00 | T NW APARTMENT | GENERAL | T NW APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T SE APARTMENT | 88.25 | Yes | Yes | 1.00 | T SE APARTMENT | GENERAL | T SE APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T NE APARTMENT | 88.25 | Yes | Yes | 1.00 | T NE APARTMENT | GENERAL | T NE APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T N1 APARTMENT | 88.25 | Yes | Yes | 1.00 | T N1 APARTMENT | GENERAL | T N1 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T N2 APARTMENT | 88.25 | Yes | Yes | 1.00 | T N2 APARTMENT | GENERAL | T N2 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T S1 APARTMENT | 88.25 | Yes | Yes | 1.00 | T S1 APARTMENT | GENERAL | T S1 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T S2 APARTMENT | 88.25 | Yes | Yes | 1.00 | T S2 APARTMENT | GENERAL | T S2 APARTMENT | 5.4896 | 35.30 | 6.6700 | |
| T CORRIDOR | 77.66 | No | Yes | 1.00 | T CORRIDOR | GENERAL | T CORRIDOR | 5.2871 | 18.58 | 0.0000 | |
| G CORRIDOR | 77.66 | No | Yes | 1.00 | G CORRIDOR | GENERAL | G CORRIDOR | 5.2871 | 18.58 | 515.3919 | |
| M CORRIDOR | 77.66 | No | Yes | 2.00 | M CORRIDOR | GENERAL | M CORRIDOR | 5.2871 | 18.58 | 0.0000 | |
| Total | 3134.61 | 5.5258 | 15.84 | 18.7777 | |||||||
| Conditioned Total | 2823.98 | 5.5521 | 17.17 | 6.6700 | |||||||
| Unconditioned Total | 310.64 | 5.2871 | 9.29 | 128.8480 | |||||||
| Not Part of Total | 0.00 | 0.0000 | 0.00 | 0.0000 |
| Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| GENERAL | 3134.61 | 2823.98 | 310.64 | 0.00 | 4.1584 | 41.91 | 17.2755 |
| Total | 3134.61 | 2823.98 | 310.64 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
End Uses| Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Time of Peak | 10-JUN-16:49 | 21-JAN-07:00 | - | - | - | - | - | - | - | - | - | - | 04-MAR-07:10 |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 32110.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 3020.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 22179.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 9362.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 14.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 23788.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 66687.50 | 23788.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | General | 32110.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | LightsWired | 2720.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| LightsPlugIn | 299.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | ElevatorLift | 3772.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| ElevatorLightsFan | 31.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| MiscPlug | 18375.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| General | 9362.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Pumps | General | 14.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Water Heater | 0.00 | 23788.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Values gathered over 8760.00 hours| Source Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
| Heating | 2.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 1087.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 231.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 104.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 1437.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 459.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 1.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 351.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 3323.67 | 351.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 0.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 385.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 81.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 37.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 509.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 162.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 124.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 1176.95 | 124.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 0.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 346.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 73.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 33.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 458.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 146.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 112.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 1060.31 | 112.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
ZoneHVAC:EnergyRecoveryVentilator| User-Specified Supply Air Flow Rate [m3/s] | User-Specified Exhaust Air Flow Rate [m3/s] | |
| G SW APARTMENT ERV | 0.025955 | 0.025955 |
| G NW APARTMENT ERV | 0.025955 | 0.025955 |
| G NE APARTMENT ERV | 0.025955 | 0.025955 |
| G N1 APARTMENT ERV | 0.025955 | 0.025955 |
| G N2 APARTMENT ERV | 0.025955 | 0.025955 |
| G S1 APARTMENT ERV | 0.025955 | 0.025955 |
| G S2 APARTMENT ERV | 0.025955 | 0.025955 |
| M SW APARTMENT ERV | 0.051909 | 0.051909 |
| M NW APARTMENT ERV | 0.051909 | 0.051909 |
| M SE APARTMENT ERV | 0.051909 | 0.051909 |
| M NE APARTMENT ERV | 0.051909 | 0.051909 |
| M N1 APARTMENT ERV | 0.051909 | 0.051909 |
| M N2 APARTMENT ERV | 0.051909 | 0.051909 |
| M S1 APARTMENT ERV | 0.051909 | 0.051909 |
| M S2 APARTMENT ERV | 0.051909 | 0.051909 |
| T SW APARTMENT ERV | 0.025955 | 0.025955 |
| T NW APARTMENT ERV | 0.025955 | 0.025955 |
| T SE APARTMENT ERV | 0.025955 | 0.025955 |
| T NE APARTMENT ERV | 0.025955 | 0.025955 |
| T N1 APARTMENT ERV | 0.025955 | 0.025955 |
| T N2 APARTMENT ERV | 0.025955 | 0.025955 |
| T S1 APARTMENT ERV | 0.025955 | 0.025955 |
| T S2 APARTMENT ERV | 0.025955 | 0.025955 |
| Design Size Maximum Flow Rate [m3/s] | |
| G SW APARTMENT ERV SUP FAN | 0.025955 |
| G SW APARTMENT ERV EXH FAN | 0.025955 |
| G NW APARTMENT ERV SUP FAN | 0.025955 |
| G NW APARTMENT ERV EXH FAN | 0.025955 |
| G NE APARTMENT ERV SUP FAN | 0.025955 |
| G NE APARTMENT ERV EXH FAN | 0.025955 |
| G N1 APARTMENT ERV SUP FAN | 0.025955 |
| G N1 APARTMENT ERV EXH FAN | 0.025955 |
| G N2 APARTMENT ERV SUP FAN | 0.025955 |
| G N2 APARTMENT ERV EXH FAN | 0.025955 |
| G S1 APARTMENT ERV SUP FAN | 0.025955 |
| G S1 APARTMENT ERV EXH FAN | 0.025955 |
| G S2 APARTMENT ERV SUP FAN | 0.025955 |
| G S2 APARTMENT ERV EXH FAN | 0.025955 |
| M SW APARTMENT ERV SUP FAN | 0.051909 |
| M SW APARTMENT ERV EXH FAN | 0.051909 |
| M NW APARTMENT ERV SUP FAN | 0.051909 |
| M NW APARTMENT ERV EXH FAN | 0.051909 |
| M SE APARTMENT ERV SUP FAN | 0.051909 |
| M SE APARTMENT ERV EXH FAN | 0.051909 |
| M NE APARTMENT ERV SUP FAN | 0.051909 |
| M NE APARTMENT ERV EXH FAN | 0.051909 |
| M N1 APARTMENT ERV SUP FAN | 0.051909 |
| M N1 APARTMENT ERV EXH FAN | 0.051909 |
| M N2 APARTMENT ERV SUP FAN | 0.051909 |
| M N2 APARTMENT ERV EXH FAN | 0.051909 |
| M S1 APARTMENT ERV SUP FAN | 0.051909 |
| M S1 APARTMENT ERV EXH FAN | 0.051909 |
| M S2 APARTMENT ERV SUP FAN | 0.051909 |
| M S2 APARTMENT ERV EXH FAN | 0.051909 |
| T SW APARTMENT ERV SUP FAN | 0.025955 |
| T SW APARTMENT ERV EXH FAN | 0.025955 |
| T NW APARTMENT ERV SUP FAN | 0.025955 |
| T NW APARTMENT ERV EXH FAN | 0.025955 |
| T SE APARTMENT ERV SUP FAN | 0.025955 |
| T SE APARTMENT ERV EXH FAN | 0.025955 |
| T NE APARTMENT ERV SUP FAN | 0.025955 |
| T NE APARTMENT ERV EXH FAN | 0.025955 |
| T N1 APARTMENT ERV SUP FAN | 0.025955 |
| T N1 APARTMENT ERV EXH FAN | 0.025955 |
| T N2 APARTMENT ERV SUP FAN | 0.025955 |
| T N2 APARTMENT ERV EXH FAN | 0.025955 |
| T S1 APARTMENT ERV SUP FAN | 0.025955 |
| T S1 APARTMENT ERV EXH FAN | 0.025955 |
| T S2 APARTMENT ERV SUP FAN | 0.025955 |
| T S2 APARTMENT ERV EXH FAN | 0.025955 |
| SPLIT GSW SUPPLY FAN | 0.364495 |
| SPLIT GNW SUPPLY FAN | 0.363761 |
| SPLIT OFFICE SUPPLY FAN | 0.425456 |
| SPLIT GNE SUPPLY FAN | 0.350417 |
| SPLIT GN1 SUPPLY FAN | 0.305242 |
| SPLIT GN2 SUPPLY FAN | 0.305010 |
| SPLIT GS1 SUPPLY FAN | 0.306531 |
| SPLIT GS2 SUPPLY FAN | 0.309487 |
| SPLIT MSW SUPPLY FAN | 0.811454 |
| SPLIT MNW SUPPLY FAN | 0.809846 |
| SPLIT MSE SUPPLY FAN | 0.778570 |
| SPLIT MNE SUPPLY FAN | 0.777003 |
| SPLIT MN1 SUPPLY FAN | 0.668015 |
| SPLIT MN2 SUPPLY FAN | 0.667476 |
| SPLIT MS1 SUPPLY FAN | 0.670533 |
| SPLIT MS2 SUPPLY FAN | 0.669989 |
| SPLIT TSW SUPPLY FAN | 0.449178 |
| SPLIT TNW SUPPLY FAN | 0.450543 |
| SPLIT TSE SUPPLY FAN | 0.425726 |
| SPLIT TNE SUPPLY FAN | 0.427073 |
| SPLIT TN1 SUPPLY FAN | 0.380470 |
| SPLIT TN2 SUPPLY FAN | 0.379698 |
| SPLIT TS1 SUPPLY FAN | 0.379327 |
| SPLIT TS2 SUPPLY FAN | 0.378557 |
| Design Size Nominal Supply Air Flow Rate [m3/s] | |
| G SW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G NW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G NE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G N1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G N2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G S1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| G S2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| M SW APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M NW APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M SE APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M NE APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M N1 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M N2 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M S1 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| M S2 APARTMENT OA HEAT EXCHANGER | 0.051909 |
| T SW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T NW APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T SE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T NE APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T N1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T N2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T S1 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| T S2 APARTMENT OA HEAT EXCHANGER | 0.025955 |
| Design Size Maximum Air Flow Rate [m3/s] | |
| G SW APARTMENT DIRECT AIR | 0.364495 |
| G NW APARTMENT DIRECT AIR | 0.363761 |
| OFFICE DIRECT AIR | 0.425456 |
| G NE APARTMENT DIRECT AIR | 0.350417 |
| G N1 APARTMENT DIRECT AIR | 0.305242 |
| G N2 APARTMENT DIRECT AIR | 0.305010 |
| G S1 APARTMENT DIRECT AIR | 0.306531 |
| G S2 APARTMENT DIRECT AIR | 0.309487 |
| M SW APARTMENT DIRECT AIR | 0.811454 |
| M NW APARTMENT DIRECT AIR | 0.809846 |
| M SE APARTMENT DIRECT AIR | 0.778570 |
| M NE APARTMENT DIRECT AIR | 0.777003 |
| M N1 APARTMENT DIRECT AIR | 0.668015 |
| M N2 APARTMENT DIRECT AIR | 0.667476 |
| M S1 APARTMENT DIRECT AIR | 0.670533 |
| M S2 APARTMENT DIRECT AIR | 0.669989 |
| T SW APARTMENT DIRECT AIR | 0.449178 |
| T NW APARTMENT DIRECT AIR | 0.450543 |
| T SE APARTMENT DIRECT AIR | 0.425726 |
| T NE APARTMENT DIRECT AIR | 0.427073 |
| T N1 APARTMENT DIRECT AIR | 0.380470 |
| T N2 APARTMENT DIRECT AIR | 0.379698 |
| T S1 APARTMENT DIRECT AIR | 0.379327 |
| T S2 APARTMENT DIRECT AIR | 0.378557 |
| Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
| SPLIT GSW | 0.364495 | 0.364495 | 0.364495 | 0.364495 | 0.364495 | 0.364495 | 1.00 | 1.00 | 0.364495 |
| SPLIT GNW | 0.363761 | 0.363761 | 0.363761 | 0.363761 | 0.363761 | 0.363761 | 1.00 | 1.00 | 0.363761 |
| SPLIT OFFICE | 0.425456 | 0.425456 | 0.425456 | 0.425456 | 0.425456 | 0.425456 | 1.00 | 1.000000 | 0.425456 |
| SPLIT GNE | 0.350417 | 0.350417 | 0.350417 | 0.350417 | 0.350417 | 0.350417 | 1.00 | 1.00 | 0.350417 |
| SPLIT GN1 | 0.305242 | 0.305242 | 0.305242 | 0.305242 | 0.305242 | 0.305242 | 1.00 | 1.00 | 0.305242 |
| SPLIT GN2 | 0.305010 | 0.305010 | 0.305010 | 0.305010 | 0.305010 | 0.305010 | 1.00 | 1.000000 | 0.305010 |
| SPLIT GS1 | 0.306531 | 0.306531 | 0.306531 | 0.306531 | 0.306531 | 0.306531 | 1.00 | 1.00 | 0.306531 |
| SPLIT GS2 | 0.309487 | 0.309487 | 0.309487 | 0.309487 | 0.309487 | 0.309487 | 1.00 | 1.00 | 0.309487 |
| SPLIT MSW | 0.811454 | 0.811454 | 0.811454 | 0.811454 | 0.811454 | 0.811454 | 1.00 | 1.00 | 0.811454 |
| SPLIT MNW | 0.809846 | 0.809846 | 0.809846 | 0.809846 | 0.809846 | 0.809846 | 1.00 | 1.00 | 0.809846 |
| SPLIT MSE | 0.778570 | 0.778570 | 0.778570 | 0.778570 | 0.778570 | 0.778570 | 1.00 | 1.00 | 0.778570 |
| SPLIT MNE | 0.777003 | 0.777003 | 0.777003 | 0.777003 | 0.777003 | 0.777003 | 1.00 | 1.000000 | 0.777003 |
| SPLIT MN1 | 0.668015 | 0.668015 | 0.668015 | 0.668015 | 0.668015 | 0.668015 | 1.00 | 1.00 | 0.668015 |
| SPLIT MN2 | 0.667476 | 0.667476 | 0.667476 | 0.667476 | 0.667476 | 0.667476 | 1.00 | 1.000000 | 0.667476 |
| SPLIT MS1 | 0.670533 | 0.670533 | 0.670533 | 0.670533 | 0.670533 | 0.670533 | 1.00 | 1.00 | 0.670533 |
| SPLIT MS2 | 0.669989 | 0.669989 | 0.669989 | 0.669989 | 0.669989 | 0.669989 | 1.00 | 1.00 | 0.669989 |
| SPLIT TSW | 0.449178 | 0.449178 | 0.449178 | 0.449178 | 0.449178 | 0.449178 | 1.00 | 1.00 | 0.449178 |
| SPLIT TNW | 0.450543 | 0.450543 | 0.450543 | 0.450543 | 0.450543 | 0.450543 | 1.00 | 1.000000 | 0.450543 |
| SPLIT TSE | 0.425726 | 0.425726 | 0.425726 | 0.425726 | 0.425726 | 0.425726 | 1.00 | 1.000000 | 0.425726 |
| SPLIT TNE | 0.427073 | 0.427073 | 0.427073 | 0.427073 | 0.427073 | 0.427073 | 1.00 | 1.00 | 0.427073 |
| SPLIT TN1 | 0.380470 | 0.380470 | 0.380470 | 0.380470 | 0.380470 | 0.380470 | 1.00 | 1.000000 | 0.380470 |
| SPLIT TN2 | 0.379698 | 0.379698 | 0.379698 | 0.379698 | 0.379698 | 0.379698 | 1.00 | 1.00 | 0.379698 |
| SPLIT TS1 | 0.379327 | 0.379327 | 0.379327 | 0.379327 | 0.379327 | 0.379327 | 1.00 | 1.00 | 0.379327 |
| SPLIT TS2 | 0.378557 | 0.378557 | 0.378557 | 0.378557 | 0.378557 | 0.378557 | 1.00 | 1.00 | 0.378557 |
| Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
| SPLIT GSW_OA_CONTROLLER | 0.364495 | 0.025955 |
| SPLIT GNW_OA_CONTROLLER | 0.363761 | 0.025955 |
| SPLIT OFFICE_OA_CONTROLLER | 0.425456 | 0.038106 |
| SPLIT GNE_OA_CONTROLLER | 0.350417 | 0.025955 |
| SPLIT GN1_OA_CONTROLLER | 0.305242 | 0.025955 |
| SPLIT GN2_OA_CONTROLLER | 0.305010 | 0.025955 |
| SPLIT GS1_OA_CONTROLLER | 0.306531 | 0.025955 |
| SPLIT GS2_OA_CONTROLLER | 0.309487 | 0.025955 |
| SPLIT MSW_OA_CONTROLLER | 0.811454 | 0.051909 |
| SPLIT MNW_OA_CONTROLLER | 0.809846 | 0.051909 |
| SPLIT MSE_OA_CONTROLLER | 0.778570 | 0.051909 |
| SPLIT MNE_OA_CONTROLLER | 0.777003 | 0.051909 |
| SPLIT MN1_OA_CONTROLLER | 0.668015 | 0.051909 |
| SPLIT MN2_OA_CONTROLLER | 0.667476 | 0.051909 |
| SPLIT MS1_OA_CONTROLLER | 0.670533 | 0.051909 |
| SPLIT MS2_OA_CONTROLLER | 0.669989 | 0.051909 |
| SPLIT TSW_OA_CONTROLLER | 0.449178 | 0.025955 |
| SPLIT TNW_OA_CONTROLLER | 0.450543 | 0.025955 |
| SPLIT TSE_OA_CONTROLLER | 0.425726 | 0.025955 |
| SPLIT TNE_OA_CONTROLLER | 0.427073 | 0.025955 |
| SPLIT TN1_OA_CONTROLLER | 0.380470 | 0.025955 |
| SPLIT TN2_OA_CONTROLLER | 0.379698 | 0.025955 |
| SPLIT TS1_OA_CONTROLLER | 0.379327 | 0.025955 |
| SPLIT TS2_OA_CONTROLLER | 0.378557 | 0.025955 |
| Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | Design Size Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | User-Specified Supplemental Heating Coil Nominal Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
| SPLIT GSW_UNITARY_PACKAGE_DX | 0.364495 | 0.364495 | 0.364495 | 0.364495 | 6512.20 | 4363.17 | 40.00 | 6512.20 | 1.00 |
| SPLIT GNW_UNITARY_PACKAGE_DX | 0.363761 | 0.363761 | 0.363761 | 0.363761 | 6457.76 | 4326.70 | 40.00 | 6457.76 | 1.00 |
| SPLIT OFFICE_UNITARY_PACKAGE_DX | 0.425456 | 0.425456 | 0.425456 | 0.425456 | 7362.06 | 4932.58 | 40.00 | 7362.06 | 1.00 |
| SPLIT GNE_UNITARY_PACKAGE_DX | 0.350417 | 0.350417 | 0.350417 | 0.350417 | 6243.28 | 4183.00 | 40.00 | 6243.28 | 1.00 |
| SPLIT GN1_UNITARY_PACKAGE_DX | 0.305242 | 0.305242 | 0.305242 | 0.305242 | 5512.09 | 3693.10 | 40.00 | 5512.09 | 1.00 |
| SPLIT GN2_UNITARY_PACKAGE_DX | 0.305010 | 0.305010 | 0.305010 | 0.305010 | 5508.35 | 3690.59 | 40.00 | 5508.35 | 1.00 |
| SPLIT GS1_UNITARY_PACKAGE_DX | 0.306531 | 0.306531 | 0.306531 | 0.306531 | 5600.84 | 3752.57 | 40.00 | 5600.84 | 1.00 |
| SPLIT GS2_UNITARY_PACKAGE_DX | 0.309487 | 0.309487 | 0.309487 | 0.309487 | 5649.04 | 3784.86 | 40.00 | 5649.04 | 1.00 |
| SPLIT MSW_UNITARY_PACKAGE_DX | 0.811454 | 0.811454 | 0.811454 | 0.811454 | 14359.57 | 9620.91 | 40.00 | 14359.57 | 1.00 |
| SPLIT MNW_UNITARY_PACKAGE_DX | 0.809846 | 0.809846 | 0.809846 | 0.809846 | 14260.50 | 9554.53 | 40.00 | 14260.50 | 1.00 |
| SPLIT MSE_UNITARY_PACKAGE_DX | 0.778570 | 0.778570 | 0.778570 | 0.778570 | 13838.86 | 9272.04 | 40.00 | 13838.86 | 1.00 |
| SPLIT MNE_UNITARY_PACKAGE_DX | 0.777003 | 0.777003 | 0.777003 | 0.777003 | 13731.44 | 9200.06 | 40.00 | 13731.44 | 1.00 |
| SPLIT MN1_UNITARY_PACKAGE_DX | 0.668015 | 0.668015 | 0.668015 | 0.668015 | 11967.75 | 8018.39 | 40.00 | 11967.75 | 1.00 |
| SPLIT MN2_UNITARY_PACKAGE_DX | 0.667476 | 0.667476 | 0.667476 | 0.667476 | 11959.06 | 8012.57 | 40.00 | 11959.06 | 1.00 |
| SPLIT MS1_UNITARY_PACKAGE_DX | 0.670533 | 0.670533 | 0.670533 | 0.670533 | 12132.37 | 8128.69 | 40.00 | 12132.37 | 1.00 |
| SPLIT MS2_UNITARY_PACKAGE_DX | 0.669989 | 0.669989 | 0.669989 | 0.669989 | 12123.76 | 8122.92 | 40.00 | 12123.76 | 1.00 |
| SPLIT TSW_UNITARY_PACKAGE_DX | 0.449178 | 0.449178 | 0.449178 | 0.449178 | 7873.36 | 5275.15 | 40.00 | 7873.36 | 1.00 |
| SPLIT TNW_UNITARY_PACKAGE_DX | 0.450543 | 0.450543 | 0.450543 | 0.450543 | 7871.05 | 5273.60 | 40.00 | 7871.05 | 1.00 |
| SPLIT TSE_UNITARY_PACKAGE_DX | 0.425726 | 0.425726 | 0.425726 | 0.425726 | 7495.58 | 5022.04 | 40.00 | 7495.58 | 1.00 |
| SPLIT TNE_UNITARY_PACKAGE_DX | 0.427073 | 0.427073 | 0.427073 | 0.427073 | 7490.69 | 5018.76 | 40.00 | 7490.69 | 1.00 |
| SPLIT TN1_UNITARY_PACKAGE_DX | 0.380470 | 0.380470 | 0.380470 | 0.380470 | 6728.08 | 4507.81 | 40.00 | 6728.08 | 1.00 |
| SPLIT TN2_UNITARY_PACKAGE_DX | 0.379698 | 0.379698 | 0.379698 | 0.379698 | 6715.58 | 4499.44 | 40.00 | 6715.58 | 1.00 |
| SPLIT TS1_UNITARY_PACKAGE_DX | 0.379327 | 0.379327 | 0.379327 | 0.379327 | 6742.38 | 4517.40 | 40.00 | 6742.38 | 1.00 |
| SPLIT TS2_UNITARY_PACKAGE_DX | 0.378557 | 0.378557 | 0.378557 | 0.378557 | 6730.02 | 4509.11 | 40.00 | 6730.02 | 1.00 |
| Design Size Rated Air Flow Rate [m3/s] | Design Size Gross Rated Total Cooling Capacity [W] | Design Size Gross Rated Sensible Heat Ratio | |
| SPLIT GSW HP COOLING COIL | 0.364495 | 6512.20 | 0.800640 |
| SPLIT GNW HP COOLING COIL | 0.363761 | 6457.76 | 0.800820 |
| SPLIT OFFICE HP COOLING COIL | 0.425456 | 7362.06 | 0.800712 |
| SPLIT GNE HP COOLING COIL | 0.350417 | 6243.28 | 0.800590 |
| SPLIT GN1 HP COOLING COIL | 0.305242 | 5512.09 | 0.800024 |
| SPLIT GN2 HP COOLING COIL | 0.305010 | 5508.35 | 0.800996 |
| SPLIT GS1 HP COOLING COIL | 0.306531 | 5600.84 | 0.800083 |
| SPLIT GS2 HP COOLING COIL | 0.309487 | 5649.04 | 0.800426 |
| SPLIT MSW HP COOLING COIL | 0.811454 | 14359.57 | 0.800918 |
| SPLIT MNW HP COOLING COIL | 0.809846 | 14260.50 | 0.800621 |
| SPLIT MSE HP COOLING COIL | 0.778570 | 13838.86 | 0.800396 |
| SPLIT MNE HP COOLING COIL | 0.777003 | 13731.44 | 0.800381 |
| SPLIT MN1 HP COOLING COIL | 0.668015 | 11967.75 | 0.800708 |
| SPLIT MN2 HP COOLING COIL | 0.667476 | 11959.06 | 0.800681 |
| SPLIT MS1 HP COOLING COIL | 0.670533 | 12132.37 | 0.800362 |
| SPLIT MS2 HP COOLING COIL | 0.669989 | 12123.76 | 0.800327 |
| SPLIT TSW HP COOLING COIL | 0.449178 | 7873.36 | 0.800208 |
| SPLIT TNW HP COOLING COIL | 0.450543 | 7871.05 | 0.800366 |
| SPLIT TSE HP COOLING COIL | 0.425726 | 7495.58 | 0.800666 |
| SPLIT TNE HP COOLING COIL | 0.427073 | 7490.69 | 0.800987 |
| SPLIT TN1 HP COOLING COIL | 0.380470 | 6728.08 | 0.800160 |
| SPLIT TN2 HP COOLING COIL | 0.379698 | 6715.58 | 0.800102 |
| SPLIT TS1 HP COOLING COIL | 0.379327 | 6742.38 | 0.800399 |
| SPLIT TS2 HP COOLING COIL | 0.378557 | 6730.02 | 0.800332 |
| Design Size Rated Air Flow Rate [m3/s] | Design Size Gross Rated Heating Capacity [W] | |
| SPLIT GSW HEATING COIL | 0.364495 | 6512.20 |
| SPLIT GNW HEATING COIL | 0.363761 | 6457.76 |
| SPLIT OFFICE HEATING COIL | 0.425456 | 7362.06 |
| SPLIT GNE HEATING COIL | 0.350417 | 6243.28 |
| SPLIT GN1 HEATING COIL | 0.305242 | 5512.09 |
| SPLIT GN2 HEATING COIL | 0.305010 | 5508.35 |
| SPLIT GS1 HEATING COIL | 0.306531 | 5600.84 |
| SPLIT GS2 HEATING COIL | 0.309487 | 5649.04 |
| SPLIT MSW HEATING COIL | 0.811454 | 14359.57 |
| SPLIT MNW HEATING COIL | 0.809846 | 14260.50 |
| SPLIT MSE HEATING COIL | 0.778570 | 13838.86 |
| SPLIT MNE HEATING COIL | 0.777003 | 13731.44 |
| SPLIT MN1 HEATING COIL | 0.668015 | 11967.75 |
| SPLIT MN2 HEATING COIL | 0.667476 | 11959.06 |
| SPLIT MS1 HEATING COIL | 0.670533 | 12132.37 |
| SPLIT MS2 HEATING COIL | 0.669989 | 12123.76 |
| SPLIT TSW HEATING COIL | 0.449178 | 7873.36 |
| SPLIT TNW HEATING COIL | 0.450543 | 7871.05 |
| SPLIT TSE HEATING COIL | 0.425726 | 7495.58 |
| SPLIT TNE HEATING COIL | 0.427073 | 7490.69 |
| SPLIT TN1 HEATING COIL | 0.380470 | 6728.08 |
| SPLIT TN2 HEATING COIL | 0.379698 | 6715.58 |
| SPLIT TS1 HEATING COIL | 0.379327 | 6742.38 |
| SPLIT TS2 HEATING COIL | 0.378557 | 6730.02 |
| Design Size Nominal Capacity [W] | |
| SPLIT GSW_SUPPHEATCOIL | 6512.20 |
| SPLIT GNW_SUPPHEATCOIL | 6457.76 |
| SPLIT OFFICE_SUPPHEATCOIL | 7362.06 |
| SPLIT GNE_SUPPHEATCOIL | 6243.28 |
| SPLIT GN1_SUPPHEATCOIL | 5512.09 |
| SPLIT GN2_SUPPHEATCOIL | 5508.35 |
| SPLIT GS1_SUPPHEATCOIL | 5600.84 |
| SPLIT GS2_SUPPHEATCOIL | 5649.04 |
| SPLIT MSW_SUPPHEATCOIL | 14359.57 |
| SPLIT MNW_SUPPHEATCOIL | 14260.50 |
| SPLIT MSE_SUPPHEATCOIL | 13838.86 |
| SPLIT MNE_SUPPHEATCOIL | 13731.44 |
| SPLIT MN1_SUPPHEATCOIL | 11967.75 |
| SPLIT MN2_SUPPHEATCOIL | 11959.06 |
| SPLIT MS1_SUPPHEATCOIL | 12132.37 |
| SPLIT MS2_SUPPHEATCOIL | 12123.76 |
| SPLIT TSW_SUPPHEATCOIL | 7873.36 |
| SPLIT TNW_SUPPHEATCOIL | 7871.05 |
| SPLIT TSE_SUPPHEATCOIL | 7495.58 |
| SPLIT TNE_SUPPHEATCOIL | 7490.69 |
| SPLIT TN1_SUPPHEATCOIL | 6728.08 |
| SPLIT TN2_SUPPHEATCOIL | 6715.58 |
| SPLIT TS1_SUPPHEATCOIL | 6742.38 |
| SPLIT TS2_SUPPHEATCOIL | 6730.02 |
| Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
| SWHSYS1 | 0.000113 | 0.013615 |
| Design Flow Rate [m3/s] | Design Power Consumption [W] | |
| SWHSYS1 PUMP | 0.000113 | 14.49 |
| Use Side Design Flow Rate [m3/s] | |
| SWHSYS1 WATER HEATER | 0.000113 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces| None |
| Possible Shadow Receivers | |
| G SWALL SWA | GWINDOW1 S SWA | |
| G WWALL SWA | GWINDOW1 W SWA | |
| G NWALL NWA | GWINDOW1 N NWA | |
| G WWALL NWA | GWINDOW1 W NWA | |
| G SWALL SEA | GWINDOW1 S SEA | |
| G EWALL SEA | GWINDOW1 E SEA | |
| G NWALL NEA | GWINDOW1 N NEA | |
| G EWALL NEA | GWINDOW1 E NEA | |
| G NWALL N1A | GWINDOW1 N N1A | |
| G NWALL N2A | GWINDOW1 N N2A | |
| G SWALL S1A | GWINDOW1 S S1A | |
| G SWALL S2A | GWINDOW1 S S2A | |
| M WWALL SWA | MWINDOW1 W SWA | |
| M SWALL SWA | MWINDOW1 S SWA | |
| M NWALL NWA | MWINDOW1 N NWA | |
| M WWALL NWA | MWINDOW1 W NWA | |
| M EWALL SEA | MWINDOW1 E SEA | |
| M SWALL SEA | MWINDOW1 S SEA | |
| M NWALL NEA | MWINDOW1 N NEA | |
| M EWALL NEA | MWINDOW1 E NEA | |
| M NWALL N1A | MWINDOW1 N N1A | |
| M NWALL N2A | MWINDOW1 N N2A | |
| M SWALL S1A | MWINDOW1 S S1A | |
| M SWALL S2A | MWINDOW1 S S2A | |
| T WWALL SWA | TWINDOW1 W SWA | |
| T SWALL SWA | TWINDOW1 S SWA | |
| T NWALL NWA | TWINDOW1 N NWA | |
| T WWALL NWA | TWINDOW1 W NWA | |
| T EWALL SEA | TWINDOW1 E SEA | |
| T SWALL SEA | TWINDOW1 S SEA | |
| T NWALL NEA | TWINDOW1 N NEA | |
| T EWALL NEA | TWINDOW1 E NEA | |
| T NWALL N1A | TWINDOW1 N N1A | |
| T NWALL N2A | TWINDOW1 N N2A | |
| T SWALL S1A | TWINDOW1 S S1A | |
| T SWALL S2A | TWINDOW1 S S2A | |
| T EWALL C | TWINDOW14 | |
| G EWALL C | ENTRANCE DOOR | |
| M EWALL C | MWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Time Not Meeting the Adaptive Comfort Models during Occupied Hours| ASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Version| Version ID | |
| 1 | 22.1 |
| #TimeSteps | Minutes per TimeStep {minutes} | |
| 1 | 6 | 10 |
| Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
| 1 | 1 | 20 | 2 | 8 |
| Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
| 1 | Yes | Yes | No | No | Yes | No |
| Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
| 1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
| Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
| 1 | 0.556 | 0.556 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 25.10 | 19.60 | 14.50 | 13.40 | 17.00 | 22.40 | 29.10 | 33.00 | 33.60 | 31.70 | 30.00 | 28.70 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Normal | Daylighting {dimensionless} | |
| 1 | 1.000 | 1.000 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
| 1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
| Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
| 1 | New Delhi-Safdarjung AP Delhi IND IWEC2 WMO#=421820 | 28.58 | 77.20 | 5.50 | 216.00 | 98757 | 1.1738 |
| Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
| 1 | Correlation | NA | 24.84 | 20.20 | NA |
| Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
| 1 | ApartmentMidRise | 0.000 | City | 4.00000E-002 | 0.40000 | FullExterior | 25 | 6 |
| Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Value {Anisotropic} | |
| 1 | Anisotropic |
| Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
| 1 | ThirdOrderBackwardDifference |
| Simulation {Yes/No} | Carbon Dioxide Concentration | |
| 1 | No | N/A |
| Simulation {Yes/No} | Generic Contaminant Concentration | |
| 1 | No | N/A |
| Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
| 1 | No | N/A | N/A | N/A |
| Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
| 1 | RegulaFalsi |
| Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
| 1 | 0.330 | 460.000 | 6.500000E-003 |
| Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
| 1 | LowerLeftCorner | Clockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
| Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
| 1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
| Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
| 1 | 0 | 0 | 0 |
| Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
| 1 | 27 | 243 | 39 |
| Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
| 1 | G SW APARTMENT | 0.0 | 0.00 | 0.00 | 0.00 | 5.79 | 3.81 | 1.52 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 2 | G NW APARTMENT | 0.0 | 0.00 | 9.30 | 0.00 | 5.79 | 13.11 | 1.52 | 1 | 1 | 1 | 0.00 | 11.58 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 3 | OFFICE | 0.0 | 34.75 | 0.00 | 0.00 | 40.54 | 3.81 | 1.52 | 1 | 1 | 1 | 34.75 | 46.33 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 4 | G NE APARTMENT | 0.0 | 34.75 | 9.30 | 0.00 | 40.54 | 13.11 | 1.52 | 1 | 1 | 1 | 34.75 | 46.33 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 5 | G N1 APARTMENT | 0.0 | 11.58 | 9.30 | 0.00 | 17.37 | 13.11 | 1.52 | 1 | 1 | 1 | 11.58 | 23.16 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 6 | G N2 APARTMENT | 0.0 | 23.16 | 9.30 | 0.00 | 28.95 | 13.11 | 1.52 | 1 | 1 | 1 | 23.16 | 34.75 | 9.30 | 16.92 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 7 | G S1 APARTMENT | 0.0 | 11.58 | 0.00 | 0.00 | 17.37 | 3.81 | 1.52 | 1 | 1 | 1 | 11.58 | 23.16 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 8 | G S2 APARTMENT | 0.0 | 23.16 | 0.00 | 0.00 | 28.95 | 3.81 | 1.52 | 1 | 1 | 1 | 23.16 | 34.75 | 0.00 | 7.62 | 0.00 | 3.05 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 9 | M SW APARTMENT | 0.0 | 0.00 | 0.00 | 3.05 | 5.79 | 3.81 | 4.57 | 1 | 1 | 2 | 0.00 | 11.58 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 10 | M NW APARTMENT | 0.0 | 0.00 | 9.30 | 3.05 | 5.79 | 13.11 | 4.57 | 1 | 1 | 2 | 0.00 | 11.58 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 11 | M SE APARTMENT | 0.0 | 34.75 | 0.00 | 3.05 | 40.54 | 3.81 | 4.57 | 1 | 1 | 2 | 34.75 | 46.33 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 12 | M NE APARTMENT | 0.0 | 34.75 | 9.30 | 3.05 | 40.54 | 13.11 | 4.57 | 1 | 1 | 2 | 34.75 | 46.33 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 13 | M N1 APARTMENT | 0.0 | 11.58 | 9.30 | 3.05 | 17.37 | 13.11 | 4.57 | 1 | 1 | 2 | 11.58 | 23.16 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 14 | M N2 APARTMENT | 0.0 | 23.16 | 9.30 | 3.05 | 28.95 | 13.11 | 4.57 | 1 | 1 | 2 | 23.16 | 34.75 | 9.30 | 16.92 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 15 | M S1 APARTMENT | 0.0 | 11.58 | 0.00 | 3.05 | 17.37 | 3.81 | 4.57 | 1 | 1 | 2 | 11.58 | 23.16 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 16 | M S2 APARTMENT | 0.0 | 23.16 | 0.00 | 3.05 | 28.95 | 3.81 | 4.57 | 1 | 1 | 2 | 23.16 | 34.75 | 0.00 | 7.62 | 3.05 | 6.10 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 17 | T SW APARTMENT | 0.0 | 0.00 | 0.00 | 9.14 | 5.79 | 3.81 | 10.67 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 18 | T NW APARTMENT | 0.0 | 0.00 | 9.30 | 9.14 | 5.79 | 13.11 | 10.67 | 1 | 1 | 1 | 0.00 | 11.58 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 19 | T SE APARTMENT | 0.0 | 34.75 | 0.00 | 9.14 | 40.54 | 3.81 | 10.67 | 1 | 1 | 1 | 34.75 | 46.33 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 20 | T NE APARTMENT | 0.0 | 34.75 | 9.30 | 9.14 | 40.54 | 13.11 | 10.67 | 1 | 1 | 1 | 34.75 | 46.33 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 58.52 | 46.82 | 11.71 | 6 | 2 | 0 | Yes |
| 21 | T N1 APARTMENT | 0.0 | 11.58 | 9.30 | 9.14 | 17.37 | 13.11 | 10.67 | 1 | 1 | 1 | 11.58 | 23.16 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 22 | T N2 APARTMENT | 0.0 | 23.16 | 9.30 | 9.14 | 28.95 | 13.11 | 10.67 | 1 | 1 | 1 | 23.16 | 34.75 | 9.30 | 16.92 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 23 | T S1 APARTMENT | 0.0 | 11.58 | 0.00 | 9.14 | 17.37 | 3.81 | 10.67 | 1 | 1 | 1 | 11.58 | 23.16 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 24 | T S2 APARTMENT | 0.0 | 23.16 | 0.00 | 9.14 | 28.95 | 3.81 | 10.67 | 1 | 1 | 1 | 23.16 | 34.75 | 0.00 | 7.62 | 9.14 | 12.19 | 3.05 | 268.97 | TARP | TARP | 88.25 | 35.30 | 28.24 | 7.06 | 6 | 1 | 0 | Yes |
| 25 | T CORRIDOR | 0.0 | 0.00 | 7.62 | 9.14 | 23.16 | 8.46 | 10.67 | 1 | 1 | 1 | 0.00 | 46.33 | 7.62 | 9.30 | 9.14 | 12.19 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 9.10 | 1.11 | 12 | 1 | 0 | Yes |
| 26 | G CORRIDOR | 0.0 | 0.00 | 7.62 | 0.00 | 23.16 | 8.46 | 1.52 | 1 | 1 | 1 | 0.00 | 46.33 | 7.62 | 9.30 | 0.00 | 3.05 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 6.90 | 3.32 | 12 | 1 | 0 | Yes |
| 27 | M CORRIDOR | 0.0 | 0.00 | 7.62 | 3.05 | 23.16 | 8.46 | 4.57 | 1 | 1 | 2 | 0.00 | 46.33 | 7.62 | 9.30 | 3.05 | 6.10 | 3.05 | 236.69 | TARP | TARP | 77.66 | 10.22 | 9.10 | 1.11 | 12 | 1 | 0 | Yes |
| Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
| 1 | G SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 2 | G NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 3 | OFFICE | 88.25 | 4.7 | 18.581 | 5.382E-002 | 7.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 14.160 | No |
| 4 | G NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 5 | G N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 6 | G N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 7 | G S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 8 | G S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 9 | M SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 10 | M NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 11 | M SE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 12 | M NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 13 | M N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 14 | M N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 15 | M S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 16 | M S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 17 | T SW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 18 | T NW APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 19 | T SE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 20 | T NE APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 21 | T N1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 22 | T N2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 23 | T S1 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 24 | T S2 APARTMENT | 88.25 | 2.5 | 35.300 | 2.833E-002 | 5.490 | 6.670 | 0.000 | 0.000 | 0.000 | 0.000 | 12.160 | No |
| 25 | T CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 5.287 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.287 | No |
| 26 | G CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 5.287 | 515.392 | 0.000 | 0.000 | 0.000 | 0.000 | 520.679 | No |
| 27 | M CORRIDOR | 77.66 | 4.2 | 18.579 | 5.382E-002 | 5.287 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.287 | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
| 1 | OCCUP_GSW | OCC_APT_SCH_WORKING_FAMILY | G SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 2 | OCCUP_GNW | OCC_APT_SCH_STAY_HOME_FAMILY | G NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 3 | OCCUP_OFFICE | OCC_OFF_W_SB_SCH | OFFICE | 88.25 | 4.7 | 4.7 | 5.382E-002 | 18.581 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 5 |
| 4 | OCCUP_GNE | OCC_APT_SCH_STAY_HOME_FAMILY | G NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 5 | OCCUP_GN1 | OCC_APT_SCH_STAY_HOME_FAMILY | G N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 6 | OCCUP_GN2 | OCC_APT_SCH_STAY_HOME_FAMILY | G N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 7 | OCCUP_GS1 | OCC_APT_SCH_WORKING_FAMILY | G S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 8 | OCCUP_GS2 | OCC_APT_SCH_WORKING_FAMILY | G S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 9 | OCCUP_MSW | OCC_APT_SCH_WORKING_FAMILY | M SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 10 | OCCUP_MNW | OCC_APT_SCH_STAY_HOME_FAMILY | M NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 11 | OCCUP_MSE | OCC_APT_SCH_WORKING_FAMILY | M SE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 12 | OCCUP_MNE | OCC_APT_SCH_STAY_HOME_FAMILY | M NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 13 | OCCUP_MN1 | OCC_APT_SCH_STAY_HOME_FAMILY | M N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 14 | OCCUP_MN2 | OCC_APT_SCH_STAY_HOME_FAMILY | M N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 15 | OCCUP_MS1 | OCC_APT_SCH_WORKING_FAMILY | M S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 16 | OCCUP_MS2 | OCC_APT_SCH_WORKING_FAMILY | M S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 17 | OCCUP_TSW | OCC_APT_SCH_WORKING_FAMILY | T SW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 18 | OCCUP_TNW | OCC_APT_SCH_STAY_HOME_FAMILY | T NW APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 19 | OCCUP_TSE | OCC_APT_SCH_WORKING_FAMILY | T SE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 20 | OCCUP_TNE | OCC_APT_SCH_STAY_HOME_FAMILY | T NE APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 21 | OCCUP_TN1 | OCC_APT_SCH_STAY_HOME_FAMILY | T N1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 22 | OCCUP_TN2 | OCC_APT_SCH_STAY_HOME_FAMILY | T N2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 3 |
| 23 | OCCUP_TS1 | OCC_APT_SCH_WORKING_FAMILY | T S1 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 24 | OCCUP_TS2 | OCC_APT_SCH_WORKING_FAMILY | T S2 APARTMENT | 88.25 | 2.5 | 2.5 | 2.833E-002 | 35.300 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 3 |
| 25 | OCCUP_T CORRIDOR | OCC_APT_SCH_CORRIDOR | T CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| 26 | OCCUP_G CORRIDOR | OCC_APT_SCH_CORRIDOR | G CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| 27 | OCCUP_M CORRIDOR | OCC_APT_SCH_CORRIDOR | M CORRIDOR | 77.66 | 4.2 | 4.2 | 5.382E-002 | 18.579 | 1.000 | 0.000 | AutoCalculate | ACTIVITY SCHEDULE | No | 3.8200E-008 | 1 | 4 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
| 1 | LIGHTING_HARDWIRED_GSW | LTG_SCH_APARTMENT_HARDWIRED | G SW APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 2 | LIGHTING_HARDWIRED_GNW | LTG_SCH_APARTMENT_HARDWIRED | G NW APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 3 | LIGHTING_HARDWIRED_OFFICE | LTG_SCH_OFFICE | OFFICE | 88.25 | 4.7 | 660.945 | 7.490 | 139.160 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 660.945 |
| 4 | LIGHTING_HARDWIRED_GNE | LTG_SCH_APARTMENT_HARDWIRED | G NE APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 5 | LIGHTING_HARDWIRED_GN1 | LTG_SCH_APARTMENT_HARDWIRED | G N1 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 6 | LIGHTING_HARDWIRED_GN2 | LTG_SCH_APARTMENT_HARDWIRED | G N2 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 7 | LIGHTING_HARDWIRED_GS1 | LTG_SCH_APARTMENT_HARDWIRED | G S1 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 8 | LIGHTING_HARDWIRED_GS2 | LTG_SCH_APARTMENT_HARDWIRED | G S2 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 9 | LIGHTING_HARDWIRED_MSW | LTG_SCH_APARTMENT_HARDWIRED | M SW APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 10 | LIGHTING_HARDWIRED_MNW | LTG_SCH_APARTMENT_HARDWIRED | M NW APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 11 | LIGHTING_HARDWIRED_MSE | LTG_SCH_APARTMENT_HARDWIRED | M SE APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 12 | LIGHTING_HARDWIRED_MNE | LTG_SCH_APARTMENT_HARDWIRED | M NE APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 13 | LIGHTING_HARDWIRED_MN1 | LTG_SCH_APARTMENT_HARDWIRED | M N1 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 14 | LIGHTING_HARDWIRED_MN2 | LTG_SCH_APARTMENT_HARDWIRED | M N2 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 15 | LIGHTING_HARDWIRED_MS1 | LTG_SCH_APARTMENT_HARDWIRED | M S1 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 16 | LIGHTING_HARDWIRED_MS2 | LTG_SCH_APARTMENT_HARDWIRED | M S2 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 17 | LIGHTING_HARDWIRED_TSW | LTG_SCH_APARTMENT_HARDWIRED | T SW APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 18 | LIGHTING_HARDWIRED_TNW | LTG_SCH_APARTMENT_HARDWIRED | T NW APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 19 | LIGHTING_HARDWIRED_TSE | LTG_SCH_APARTMENT_HARDWIRED | T SE APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 20 | LIGHTING_HARDWIRED_TNE | LTG_SCH_APARTMENT_HARDWIRED | T NE APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 21 | LIGHTING_HARDWIRED_TN1 | LTG_SCH_APARTMENT_HARDWIRED | T N1 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 22 | LIGHTING_HARDWIRED_TN2 | LTG_SCH_APARTMENT_HARDWIRED | T N2 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 23 | LIGHTING_HARDWIRED_TS1 | LTG_SCH_APARTMENT_HARDWIRED | T S1 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 24 | LIGHTING_HARDWIRED_TS2 | LTG_SCH_APARTMENT_HARDWIRED | T S2 APARTMENT | 88.25 | 2.5 | 398.961 | 4.521 | 159.584 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 398.961 |
| 25 | LIGHTING_HARDWIRED_GC | LTG_SCH_CORRIDOR | G CORRIDOR | 77.66 | 4.2 | 410.594 | 5.287 | 98.228 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 410.594 |
| 26 | LIGHTING_HARDWIRED_MC | LTG_SCH_CORRIDOR | M CORRIDOR | 77.66 | 4.2 | 410.594 | 5.287 | 98.228 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 410.594 |
| 27 | LIGHTING_HARDWIRED_TC | LTG_SCH_CORRIDOR | T CORRIDOR | 77.66 | 4.2 | 410.594 | 5.287 | 98.228 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsWired | 0.000 | 410.594 |
| 28 | LIGHTING_PLUGIN_GSW | LTG_SCH_APARTMENT_PLUGIN | G SW APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 29 | LIGHTING_PLUGIN_GNW | LTG_SCH_APARTMENT_PLUGIN | G NW APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 30 | LIGHTING_PLUGIN_GNE | LTG_SCH_APARTMENT_PLUGIN | G NE APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 31 | LIGHTING_PLUGIN_GN1 | LTG_SCH_APARTMENT_PLUGIN | G N1 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 32 | LIGHTING_PLUGIN_GN2 | LTG_SCH_APARTMENT_PLUGIN | G N2 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 33 | LIGHTING_PLUGIN_GS1 | LTG_SCH_APARTMENT_PLUGIN | G S1 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 34 | LIGHTING_PLUGIN_GS2 | LTG_SCH_APARTMENT_PLUGIN | G S2 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 35 | LIGHTING_PLUGIN_MSW | LTG_SCH_APARTMENT_PLUGIN | M SW APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 36 | LIGHTING_PLUGIN_MNW | LTG_SCH_APARTMENT_PLUGIN | M NW APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 37 | LIGHTING_PLUGIN_MSE | LTG_SCH_APARTMENT_PLUGIN | M SE APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 38 | LIGHTING_PLUGIN_MNE | LTG_SCH_APARTMENT_PLUGIN | M NE APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 39 | LIGHTING_PLUGIN_MN1 | LTG_SCH_APARTMENT_PLUGIN | M N1 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 40 | LIGHTING_PLUGIN_MN2 | LTG_SCH_APARTMENT_PLUGIN | M N2 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 41 | LIGHTING_PLUGIN_MS1 | LTG_SCH_APARTMENT_PLUGIN | M S1 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 42 | LIGHTING_PLUGIN_MS2 | LTG_SCH_APARTMENT_PLUGIN | M S2 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 43 | LIGHTING_PLUGIN_TSW | LTG_SCH_APARTMENT_PLUGIN | T SW APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 44 | LIGHTING_PLUGIN_TNW | LTG_SCH_APARTMENT_PLUGIN | T NW APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 45 | LIGHTING_PLUGIN_TSE | LTG_SCH_APARTMENT_PLUGIN | T SE APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 46 | LIGHTING_PLUGIN_TNE | LTG_SCH_APARTMENT_PLUGIN | T NE APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 47 | LIGHTING_PLUGIN_TN1 | LTG_SCH_APARTMENT_PLUGIN | T N1 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 48 | LIGHTING_PLUGIN_TN2 | LTG_SCH_APARTMENT_PLUGIN | T N2 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 49 | LIGHTING_PLUGIN_TS1 | LTG_SCH_APARTMENT_PLUGIN | T S1 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| 50 | LIGHTING_PLUGIN_TS2 | LTG_SCH_APARTMENT_PLUGIN | T S2 APARTMENT | 88.25 | 2.5 | 85.491 | 0.969 | 34.197 | 0.000 | 0.600 | 0.200 | 0.200 | 1.000 | LightsPlugIn | 0.000 | 85.491 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
| 1 | ELEVATOR_LIFT_RUNNING | ELEVATOR_RUNNING_SCH | G CORRIDOR | 77.66 | 4.2 | 38362.000 | 493.978 | 9177.512 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLift | 0.000 | 2585.215 |
| 2 | ELEVATOR_LIFT_STANDBY | ELEVATOR_STANDBY_SCH | G CORRIDOR | 77.66 | 4.2 | 1600.000 | 20.603 | 382.775 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLift | 1187.152 | 1600.000 |
| 3 | ELEVATORS_LIGHTS_FAN | ELEV_LIGHT_FAN_SCH_ADD_DF | G CORRIDOR | 77.66 | 4.2 | 63.000 | 0.811 | 15.072 | 0.000 | 0.000 | 0.950 | 5.000E-002 | ElevatorLightsFan | 3.150 | 31.500 |
| 4 | PLUG_GSW | EQP_APT_SCH | G SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 5 | PLUG_GNW | EQP_APT_SCH | G NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 6 | PLUG_OFFICE | EQP_OFF_SCH | OFFICE | 88.25 | 4.7 | 588.623 | 6.670 | 123.933 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 588.623 |
| 7 | PLUG_GNE | EQP_APT_SCH | G NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 8 | PLUG_GN1 | EQP_APT_SCH | G N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 9 | PLUG_GN2 | EQP_APT_SCH | G N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 10 | PLUG_GS1 | EQP_APT_SCH | G S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 11 | PLUG_GS2 | EQP_APT_SCH | G S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 12 | PLUG_MSW | EQP_APT_SCH | M SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 13 | PLUG_MNW | EQP_APT_SCH | M NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 14 | PLUG_MSE | EQP_APT_SCH | M SE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 15 | PLUG_MNE | EQP_APT_SCH | M NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 16 | PLUG_MN1 | EQP_APT_SCH | M N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 17 | PLUG_MN2 | EQP_APT_SCH | M N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 18 | PLUG_MS1 | EQP_APT_SCH | M S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 19 | PLUG_MS2 | EQP_APT_SCH | M S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 20 | PLUG_TSW | EQP_APT_SCH | T SW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 21 | PLUG_TNW | EQP_APT_SCH | T NW APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 22 | PLUG_TSE | EQP_APT_SCH | T SE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 23 | PLUG_TNE | EQP_APT_SCH | T NE APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 24 | PLUG_TN1 | EQP_APT_SCH | T N1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 25 | PLUG_TN2 | EQP_APT_SCH | T N2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 26 | PLUG_TS1 | EQP_APT_SCH | T S1 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| 27 | PLUG_TS2 | EQP_APT_SCH | T S2 APARTMENT | 88.25 | 2.5 | 588.623 | 6.670 | 235.449 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 223.677 | 588.623 |
| Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
| 1 | PolygonClipping | Periodic | 20 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
| Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
| 1 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | 0.9460 | 53912.0 | 11.449 | 0.4600 |
| Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
| 1 | G SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 2 | GWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 3 | G WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 4 | GWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 5 | G NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 6 | G EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 7 | G GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 8 | G CEILIN SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 9 | G INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 10 | G NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 11 | GWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 12 | G WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 13 | GWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 14 | G SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 15 | G EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 16 | G GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 17 | G CEILIN NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 18 | G INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 19 | G SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 20 | GWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 21 | G EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 22 | GWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 23 | G NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 24 | iz-G EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 25 | G GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 26 | G CEILIN SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 27 | G INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 28 | G NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 29 | GWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 30 | G EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 31 | GWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 32 | G SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 33 | iz-G EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 34 | G GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 35 | G CEILIN NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 36 | G INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 37 | G NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 38 | GWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 39 | G SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 40 | G EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 41 | iz-G EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 42 | G GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 43 | G CEILIN N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 44 | G INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 45 | G NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 46 | GWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 47 | G SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 48 | G EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 49 | iz-G EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 50 | G GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 51 | G CEILIN N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 52 | G INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 53 | G SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 54 | GWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 55 | G NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 56 | G EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 57 | iz-G EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 58 | G GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 59 | G CEILIN S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 60 | G INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 61 | G SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 62 | GWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 63 | G NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 64 | G EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 65 | iz-G EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 66 | G GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 67 | G CEILIN S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 68 | G INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 69 | M WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 70 | MWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 71 | M SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 72 | MWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 73 | M NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 74 | M EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 75 | M GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 76 | M CEILIN SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 77 | M INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 78 | M NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 79 | MWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 80 | M WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 81 | MWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 82 | M SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 83 | M EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 84 | M GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 85 | M CEILIN NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 86 | M INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 87 | M EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 88 | MWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 89 | M SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 90 | MWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 91 | M NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 92 | iz-M EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 93 | M GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 94 | M CEILIN SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 95 | M INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 96 | M NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 97 | MWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 98 | M EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 99 | MWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 100 | M SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 101 | iz-M EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 102 | M GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 103 | M CEILIN NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 104 | M INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 105 | M NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 106 | MWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 107 | M SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 108 | M EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 109 | iz-M EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 110 | M GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 111 | M CEILIN N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 112 | M INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 113 | M NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 114 | MWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 115 | M SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 116 | M EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 117 | iz-M EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 118 | M GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 119 | M CEILIN N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 120 | M INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 121 | M SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 122 | MWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 123 | M NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 124 | M EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 125 | iz-M EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 126 | M GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 127 | M CEILIN S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 128 | M INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 129 | M SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 130 | MWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 131 | M NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 132 | M EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 133 | iz-M EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 134 | M GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 135 | M CEILIN S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 136 | M INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 137 | T WWALL SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 138 | TWINDOW1 W SWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 139 | T SWALL SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 140 | TWINDOW1 S SWA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 141 | T NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 142 | T EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 143 | T GFLOOR SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 144 | T ROOF SWA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 145 | T INTERNALMASS SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 146 | T NWALL NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 147 | TWINDOW1 N NWA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 148 | T WWALL NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 149 | TWINDOW1 W NWA | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 150 | T SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 151 | T EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 152 | T GFLOOR NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 153 | T ROOF NWA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 154 | T INTERNALMASS NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 155 | T EWALL SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 156 | TWINDOW1 E SEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 157 | T SWALL SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 158 | TWINDOW1 S SEA | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 159 | T NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 160 | iz-T EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 161 | T GFLOOR SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 162 | T ROOF SEA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 163 | T INTERNALMASS SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 164 | T NWALL NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 165 | TWINDOW1 N NEA | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 166 | T EWALL NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 3 | No | No |
| 167 | TWINDOW1 E NEA | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 2 | No | No |
| 168 | T SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 169 | iz-T EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 170 | T GFLOOR NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 171 | T ROOF NEA | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 172 | T INTERNALMASS NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 19.20 | 9.19 | 0.20 | 0 | No | No |
| 173 | T NWALL N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 174 | TWINDOW1 N N1A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 175 | T SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 176 | T EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 177 | iz-T EIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 178 | T GFLOOR N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 179 | T ROOF N1A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 180 | T INTERNALMASS N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 181 | T NWALL N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 182 | TWINDOW1 N N2A | 0 | 423.60 | 123.02 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 183 | T SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 184 | T EIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 185 | iz-T EIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 186 | T GFLOOR N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 187 | T ROOF N2A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 188 | T INTERNALMASS N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 189 | T SWALL S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 190 | TWINDOW1 S S1A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 191 | T NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 192 | T EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 193 | iz-T EIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 194 | T GFLOOR S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 195 | T ROOF S1A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 196 | T INTERNALMASS S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 197 | T SWALL S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 3 | No | No |
| 198 | TWINDOW1 S S2A | 0 | 423.60 | 117.04 | 12.19 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 2 | No | No |
| 199 | T NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 200 | T EIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 201 | iz-T EIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 202 | T GFLOOR S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 203 | T ROOF S2A | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 204 | T INTERNALMASS S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 11.58 | 9.19 | 0.20 | 0 | No | No |
| 205 | T WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 206 | T EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 207 | TWINDOW14 | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 2 | No | No |
| 208 | iz-T NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 209 | iz-T NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 210 | iz-T NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 211 | iz-T NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 212 | iz-T SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 213 | iz-T SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 214 | iz-T SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 215 | iz-T SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 216 | T FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 217 | T ROOF C | 0 | 783.65 | 155.90 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 218 | G WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 4 | No | No |
| 219 | G EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 4 | No | No |
| 220 | ENTRANCE DOOR | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 1 | No | No |
| 221 | iz-G NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 222 | iz-G NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 223 | iz-G NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 224 | iz-G NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 225 | iz-G SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 226 | iz-G SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 227 | iz-G SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 228 | iz-G SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 229 | G FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 230 | G CEILING C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.32 | 0 | No | No |
| 231 | M WWALL C | 0 | 154.67 | 58.21 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 4 | No | No |
| 232 | M EWALL C | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 3 | No | No |
| 233 | MWINDOW14 | 0 | 154.67 | 123.02 | 12.19 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 2 | No | No |
| 234 | iz-M NIWALL SWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 235 | iz-M NIWALL S1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 236 | iz-M NIWALL S2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 237 | iz-M NIWALL SEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 238 | iz-M SIWALL NWA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 239 | iz-M SIWALL N1A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 240 | iz-M SIWALL N2A | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 241 | iz-M SIWALL NEA | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 242 | M FLOOR C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| 243 | M CEILING C | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.35 | 3.24 | 0.11 | 0 | No | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
| 1 | INFIL_GSW | INF_APT_SCH | G SW APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 2 | INFIL_GNW | INF_APT_SCH | G NW APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 3 | INFIL_OFFICE | INF_OFF_SCH | OFFICE | 88.25 | 4.7 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 4 | INFIL_GNE | INF_APT_SCH | G NE APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 5 | INFIL_GN1 | INF_APT_SCH | G N1 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 6 | INFIL_GN2 | INF_APT_SCH | G N2 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 7 | INFIL_GS1 | INF_APT_SCH | G S1 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 8 | INFIL_GS2 | INF_APT_SCH | G S2 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 9 | INFIL_MSW | INF_APT_SCH | M SW APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 10 | INFIL_MNW | INF_APT_SCH | M NW APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 11 | INFIL_MSE | INF_APT_SCH | M SE APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 12 | INFIL_MNE | INF_APT_SCH | M NE APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 2.563E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 13 | INFIL_MN1 | INF_APT_SCH | M N1 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 14 | INFIL_MN2 | INF_APT_SCH | M N2 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 15 | INFIL_MS1 | INF_APT_SCH | M S1 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 16 | INFIL_MS2 | INF_APT_SCH | M S2 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 2.563E-004 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 17 | INFIL_SW | INF_APT_SCH | T SW APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 1.022E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 18 | INFIL_NW | INF_APT_SCH | T NW APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 1.022E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 19 | INFIL_SE | INF_APT_SCH | T SE APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 1.022E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 20 | INFIL_NE | INF_APT_SCH | T NE APARTMENT | 88.25 | 2.5 | 1.500E-002 | 1.700E-004 | 1.022E-004 | 0.201 | 0.000 | 0.000 | 0.224 | 0.000 |
| 21 | INFIL_TN1 | INF_APT_SCH | T N1 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 7.323E-005 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 22 | INFIL_TN2 | INF_APT_SCH | T N2 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 7.323E-005 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 23 | INFIL_TS1 | INF_APT_SCH | T S1 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 7.323E-005 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 24 | INFIL_TS2 | INF_APT_SCH | T S2 APARTMENT | 88.25 | 2.5 | 9.048E-003 | 1.025E-004 | 7.323E-005 | 0.121 | 0.000 | 0.000 | 0.224 | 0.000 |
| 25 | INFIL_GC | INF_COR_SCH | G CORRIDOR | 77.66 | 4.2 | 2.619E-003 | 3.372E-005 | 2.563E-004 | 3.983E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| 26 | DOOR_INFIL_GC | INFIL_DOOR_OPENING_SCH | G CORRIDOR | 77.66 | 4.2 | 0.521 | 6.703E-003 | 5.094E-002 | 7.917 | 1.000 | 0.000 | 0.000 | 0.000 |
| 27 | INFIL_MC | INF_COR_SCH | M CORRIDOR | 77.66 | 4.2 | 2.619E-003 | 3.372E-005 | 2.563E-004 | 3.983E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| 28 | INFIL_TC | INF_COR_SCH | T CORRIDOR | 77.66 | 4.2 | 2.619E-003 | 3.372E-005 | 2.980E-005 | 3.983E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
| 1 | G SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 2 | G NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 3 | G NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 4 | G N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 5 | G N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 6 | G S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 7 | G S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | G S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 8 | M SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 9 | M NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 10 | M SE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M SE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 11 | M NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 12 | M N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 13 | M N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 14 | M S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 15 | M S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | M S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 16 | T SW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T SW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 17 | T NW APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T NW APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 18 | T SE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T SE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 19 | T NE APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T NE APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 20 | T N1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T N1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 21 | T N2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T N2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 22 | T S1 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T S1 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| 23 | T S2 APARTMENT SLIDING DOOR VENTILATION | Constant-0.0 | T S2 APARTMENT | 88.25 | 2.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
| Simple | |
| 1 | Simple |
| Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
| 1 | G SW APARTMENT | Mixing/Well-Stirred |
| 2 | G NW APARTMENT | Mixing/Well-Stirred |
| 3 | OFFICE | Mixing/Well-Stirred |
| 4 | G NE APARTMENT | Mixing/Well-Stirred |
| 5 | G N1 APARTMENT | Mixing/Well-Stirred |
| 6 | G N2 APARTMENT | Mixing/Well-Stirred |
| 7 | G S1 APARTMENT | Mixing/Well-Stirred |
| 8 | G S2 APARTMENT | Mixing/Well-Stirred |
| 9 | M SW APARTMENT | Mixing/Well-Stirred |
| 10 | M NW APARTMENT | Mixing/Well-Stirred |
| 11 | M SE APARTMENT | Mixing/Well-Stirred |
| 12 | M NE APARTMENT | Mixing/Well-Stirred |
| 13 | M N1 APARTMENT | Mixing/Well-Stirred |
| 14 | M N2 APARTMENT | Mixing/Well-Stirred |
| 15 | M S1 APARTMENT | Mixing/Well-Stirred |
| 16 | M S2 APARTMENT | Mixing/Well-Stirred |
| 17 | T SW APARTMENT | Mixing/Well-Stirred |
| 18 | T NW APARTMENT | Mixing/Well-Stirred |
| 19 | T SE APARTMENT | Mixing/Well-Stirred |
| 20 | T NE APARTMENT | Mixing/Well-Stirred |
| 21 | T N1 APARTMENT | Mixing/Well-Stirred |
| 22 | T N2 APARTMENT | Mixing/Well-Stirred |
| 23 | T S1 APARTMENT | Mixing/Well-Stirred |
| 24 | T S2 APARTMENT | Mixing/Well-Stirred |
| 25 | T CORRIDOR | Mixing/Well-Stirred |
| 26 | G CORRIDOR | Mixing/Well-Stirred |
| 27 | M CORRIDOR | Mixing/Well-Stirred |
| No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
| 1 | NoMultizoneOrDistribution |
| Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
| 1 | 1.000 | 1.000 | 1.000 | 1.000 |
| Value | |
| 1 | 6 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.2000 |
| 2 | Zone G SW APARTMENT | 1.2000 |
| 3 | Zone G NW APARTMENT | 1.2000 |
| 4 | Zone OFFICE | 1.2000 |
| 5 | Zone G NE APARTMENT | 1.2000 |
| 6 | Zone G N1 APARTMENT | 1.2000 |
| 7 | Zone G N2 APARTMENT | 1.2000 |
| 8 | Zone G S1 APARTMENT | 1.2000 |
| 9 | Zone G S2 APARTMENT | 1.2000 |
| 10 | Zone M SW APARTMENT | 1.2000 |
| 11 | Zone M NW APARTMENT | 1.2000 |
| 12 | Zone M SE APARTMENT | 1.2000 |
| 13 | Zone M NE APARTMENT | 1.2000 |
| 14 | Zone M N1 APARTMENT | 1.2000 |
| 15 | Zone M N2 APARTMENT | 1.2000 |
| 16 | Zone M S1 APARTMENT | 1.2000 |
| 17 | Zone M S2 APARTMENT | 1.2000 |
| 18 | Zone T SW APARTMENT | 1.2000 |
| 19 | Zone T NW APARTMENT | 1.2000 |
| 20 | Zone T SE APARTMENT | 1.2000 |
| 21 | Zone T NE APARTMENT | 1.2000 |
| 22 | Zone T N1 APARTMENT | 1.2000 |
| 23 | Zone T N2 APARTMENT | 1.2000 |
| 24 | Zone T S1 APARTMENT | 1.2000 |
| 25 | Zone T S2 APARTMENT | 1.2000 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.2000 |
| 2 | Zone G SW APARTMENT | 1.2000 |
| 3 | Zone G NW APARTMENT | 1.2000 |
| 4 | Zone OFFICE | 1.2000 |
| 5 | Zone G NE APARTMENT | 1.2000 |
| 6 | Zone G N1 APARTMENT | 1.2000 |
| 7 | Zone G N2 APARTMENT | 1.2000 |
| 8 | Zone G S1 APARTMENT | 1.2000 |
| 9 | Zone G S2 APARTMENT | 1.2000 |
| 10 | Zone M SW APARTMENT | 1.2000 |
| 11 | Zone M NW APARTMENT | 1.2000 |
| 12 | Zone M SE APARTMENT | 1.2000 |
| 13 | Zone M NE APARTMENT | 1.2000 |
| 14 | Zone M N1 APARTMENT | 1.2000 |
| 15 | Zone M N2 APARTMENT | 1.2000 |
| 16 | Zone M S1 APARTMENT | 1.2000 |
| 17 | Zone M S2 APARTMENT | 1.2000 |
| 18 | Zone T SW APARTMENT | 1.2000 |
| 19 | Zone T NW APARTMENT | 1.2000 |
| 20 | Zone T SE APARTMENT | 1.2000 |
| 21 | Zone T NE APARTMENT | 1.2000 |
| 22 | Zone T N1 APARTMENT | 1.2000 |
| 23 | Zone T N2 APARTMENT | 1.2000 |
| 24 | Zone T S1 APARTMENT | 1.2000 |
| 25 | Zone T S2 APARTMENT | 1.2000 |
| Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
| 1 | G SW APARTMENT | Cooling | 4188.84389 | 5026.61267 | 0.30375 | 0.36449 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 38.21700 | 9.15158E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 2 | G SW APARTMENT | Heating | 729.78561 | 875.74273 | 3.22602E-002 | 3.87122E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6.30000 | 6.07234E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 3 | G NW APARTMENT | Cooling | 4180.69628 | 5016.83554 | 0.30313 | 0.36376 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 38.21700 | 9.15158E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 4 | G NW APARTMENT | Heating | 608.76251 | 730.51501 | 2.69109E-002 | 3.22931E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30000 | 6.07234E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 5 | OFFICE | Cooling | 4816.11082 | 5779.33298 | 0.35455 | 0.42546 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 09:00:00 | 36.66500 | 9.14901E-003 | 88.24927 | 4.74953 | 3.81060E-002 | 0.00000 |
| 6 | OFFICE | Heating | 1040.02947 | 1248.03537 | 4.59746E-002 | 5.51695E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | 6.30000 | 6.07234E-003 | 88.24927 | 4.74953 | 3.81060E-002 | 0.00000 |
| 7 | G NE APARTMENT | Cooling | 4031.34941 | 4837.61929 | 0.29201 | 0.35042 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 38.21700 | 9.15158E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 8 | G NE APARTMENT | Heating | 608.34486 | 730.01384 | 2.68925E-002 | 3.22710E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30000 | 6.07234E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 9 | G N1 APARTMENT | Cooling | 3523.38614 | 4228.06337 | 0.25437 | 0.30524 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 38.21700 | 9.15158E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 10 | G N1 APARTMENT | Heating | 285.70716 | 342.84860 | 1.26300E-002 | 2.59546E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30000 | 6.07234E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 11 | G N2 APARTMENT | Cooling | 3520.77282 | 4224.92738 | 0.25418 | 0.30501 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 38.21700 | 9.15158E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 12 | G N2 APARTMENT | Heating | 285.69491 | 342.83390 | 1.26294E-002 | 2.59546E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6.30000 | 6.07234E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 13 | G S1 APARTMENT | Cooling | 3537.84221 | 4245.41065 | 0.25544 | 0.30653 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 38.21700 | 9.15158E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 14 | G S1 APARTMENT | Heating | 406.73422 | 488.08107 | 1.79797E-002 | 2.59546E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6.30000 | 6.07234E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 15 | G S2 APARTMENT | Cooling | 3570.98405 | 4285.18086 | 0.25791 | 0.30949 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 38.21700 | 9.15158E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 16 | G S2 APARTMENT | Heating | 414.97652 | 497.97182 | 1.83441E-002 | 2.59546E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:30:00 | 6.30000 | 6.07234E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 17 | M SW APARTMENT | Cooling | 9303.98957 | 11164.78749 | 0.67621 | 0.81145 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 38.21700 | 9.15158E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 18 | M SW APARTMENT | Heating | 1595.85789 | 1915.02946 | 7.05449E-002 | 8.46539E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6.30000 | 6.07234E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 19 | M NW APARTMENT | Cooling | 9286.03716 | 11143.24460 | 0.67487 | 0.80985 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 38.21700 | 9.15158E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 20 | M NW APARTMENT | Heating | 1319.54345 | 1583.45214 | 5.83316E-002 | 6.99979E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6.30000 | 6.07234E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 21 | M SE APARTMENT | Cooling | 8934.14812 | 10720.97775 | 0.64881 | 0.77857 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 38.21700 | 9.15158E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 22 | M SE APARTMENT | Heating | 1594.80560 | 1913.76672 | 7.04984E-002 | 8.45981E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6.30000 | 6.07234E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 23 | M NE APARTMENT | Cooling | 8916.69353 | 10700.03223 | 0.64750 | 0.77700 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 38.21700 | 9.15158E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 24 | M NE APARTMENT | Heating | 1318.39956 | 1582.07947 | 5.82810E-002 | 6.99372E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6.30000 | 6.07234E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 25 | M N1 APARTMENT | Cooling | 7695.79133 | 9234.94959 | 0.55668 | 0.66802 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 38.21700 | 9.15158E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 26 | M N1 APARTMENT | Heating | 551.10636 | 661.32763 | 2.43622E-002 | 5.19091E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6.30000 | 6.07234E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 27 | M N2 APARTMENT | Cooling | 7689.76955 | 9227.72346 | 0.55623 | 0.66748 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 38.21700 | 9.15158E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 28 | M N2 APARTMENT | Heating | 551.07688 | 661.29225 | 2.43609E-002 | 5.19091E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6.30000 | 6.07234E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 29 | M S1 APARTMENT | Cooling | 7723.76022 | 9268.51227 | 0.55878 | 0.67053 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 38.21700 | 9.15158E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 30 | M S1 APARTMENT | Heating | 819.85996 | 983.83195 | 3.62419E-002 | 5.19091E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6.30000 | 6.07234E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 31 | M S2 APARTMENT | Cooling | 7717.68066 | 9261.21679 | 0.55832 | 0.66999 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 38.21700 | 9.15158E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 32 | M S2 APARTMENT | Heating | 819.83306 | 983.79967 | 3.62407E-002 | 5.19091E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6.30000 | 6.07234E-003 | 88.24927 | 2.50000 | 5.19091E-002 | 0.00000 |
| 33 | T SW APARTMENT | Cooling | 5144.55019 | 6173.46023 | 0.37431 | 0.44918 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 38.21700 | 9.15158E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 34 | T SW APARTMENT | Heating | 1358.03734 | 1629.64480 | 6.00320E-002 | 7.20384E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6.30000 | 6.07234E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 35 | T NW APARTMENT | Cooling | 5159.88843 | 6191.86611 | 0.37545 | 0.45054 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 38.21700 | 9.15158E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 36 | T NW APARTMENT | Heating | 1210.35280 | 1452.42336 | 5.35047E-002 | 6.42056E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6.30000 | 6.07234E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 37 | T SE APARTMENT | Cooling | 4880.30951 | 5856.37142 | 0.35477 | 0.42573 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 38.21700 | 9.15158E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 38 | T SE APARTMENT | Heating | 1357.37103 | 1628.84524 | 6.00026E-002 | 7.20031E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6.30000 | 6.07234E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 39 | T NE APARTMENT | Cooling | 4895.54398 | 5874.65278 | 0.35589 | 0.42707 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 38.21700 | 9.15158E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 40 | T NE APARTMENT | Heating | 1209.61681 | 1451.54017 | 5.34721E-002 | 6.41666E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6.30000 | 6.07234E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 41 | T N1 APARTMENT | Cooling | 4370.42915 | 5244.51498 | 0.31706 | 0.38047 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 38.21700 | 9.15158E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 42 | T N1 APARTMENT | Heating | 806.42102 | 967.70523 | 3.56486E-002 | 4.27783E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6.30000 | 6.07234E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 43 | T N2 APARTMENT | Cooling | 4361.74923 | 5234.09907 | 0.31642 | 0.37970 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 38.21700 | 9.15158E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 44 | T N2 APARTMENT | Heating | 806.39876 | 967.67851 | 3.56476E-002 | 4.27771E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6.30000 | 6.07234E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 45 | T S1 APARTMENT | Cooling | 4357.54233 | 5229.05080 | 0.31611 | 0.37933 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 38.21700 | 9.15158E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 46 | T S1 APARTMENT | Heating | 955.04055 | 1146.04866 | 4.22176E-002 | 5.06611E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6.30000 | 6.07234E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 47 | T S2 APARTMENT | Cooling | 4348.87854 | 5218.65425 | 0.31546 | 0.37856 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 38.21700 | 9.15158E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| 48 | T S2 APARTMENT | Heating | 955.02052 | 1146.02462 | 4.22167E-002 | 5.06600E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6.30000 | 6.07234E-003 | 88.24927 | 2.50000 | 2.59546E-002 | 0.00000 |
| System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
| 1 | SPLIT GSW | Cooling | Sensible | 5268.57 | 0.36449 | 0.36449 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 2 | SPLIT GSW | Heating | Sensible | 1316.06 | 3.87122E-002 | 3.87122E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 3 | SPLIT GNW | Cooling | Sensible | 5258.88 | 0.36376 | 0.36376 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 4 | SPLIT GNW | Heating | Sensible | 1172.96 | 3.22931E-002 | 3.22931E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 |
| 5 | SPLIT OFFICE | Cooling | Sensible | 6171.43 | 0.42546 | 0.42546 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 6 | SPLIT OFFICE | Heating | Sensible | 1895.05 | 5.51695E-002 | 5.51695E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 |
| 7 | SPLIT GNE | Cooling | Sensible | 5081.16 | 0.35042 | 0.35042 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 8 | SPLIT GNE | Heating | Sensible | 1172.47 | 3.22710E-002 | 3.22710E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 |
| 9 | SPLIT GN1 | Cooling | Sensible | 4478.55 | 0.30524 | 0.30524 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 10 | SPLIT GN1 | Heating | Sensible | 1031.66 | 2.59546E-002 | 2.59546E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 11 | SPLIT GN2 | Cooling | Sensible | 4475.46 | 0.30501 | 0.30501 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 12 | SPLIT GN2 | Heating | Sensible | 1031.66 | 2.59546E-002 | 2.59546E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 13 | SPLIT GS1 | Cooling | Sensible | 4495.67 | 0.30653 | 0.30653 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 14 | SPLIT GS1 | Heating | Sensible | 1031.66 | 2.59546E-002 | 2.59546E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 15 | SPLIT GS2 | Cooling | Sensible | 4534.97 | 0.30949 | 0.30949 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 16 | SPLIT GS2 | Heating | Sensible | 1031.66 | 2.59546E-002 | 2.59546E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 17 | SPLIT MSW | Cooling | Sensible | 11636.85 | 0.81145 | 0.81145 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 18 | SPLIT MSW | Heating | Sensible | 2793.28 | 8.46539E-002 | 8.46539E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 19 | SPLIT MNW | Cooling | Sensible | 11615.57 | 0.80985 | 0.80985 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 20 | SPLIT MNW | Heating | Sensible | 2466.56 | 6.99979E-002 | 6.99979E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 21 | SPLIT MSE | Cooling | Sensible | 11198.25 | 0.77857 | 0.77857 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 22 | SPLIT MSE | Heating | Sensible | 2792.04 | 8.45981E-002 | 8.45981E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 23 | SPLIT MNE | Cooling | Sensible | 11177.54 | 0.77700 | 0.77700 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 24 | SPLIT MNE | Heating | Sensible | 2465.20 | 6.99372E-002 | 6.99372E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 25 | SPLIT MN1 | Cooling | Sensible | 9726.03 | 0.66802 | 0.66802 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 26 | SPLIT MN1 | Heating | Sensible | 2063.32 | 5.19091E-002 | 5.19091E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 27 | SPLIT MN2 | Cooling | Sensible | 9718.85 | 0.66748 | 0.66748 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 28 | SPLIT MN2 | Heating | Sensible | 2063.32 | 5.19091E-002 | 5.19091E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 29 | SPLIT MS1 | Cooling | Sensible | 9759.35 | 0.67053 | 0.67053 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 30 | SPLIT MS1 | Heating | Sensible | 2063.32 | 5.19091E-002 | 5.19091E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 31 | SPLIT MS2 | Cooling | Sensible | 9752.10 | 0.66999 | 0.66999 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 32 | SPLIT MS2 | Heating | Sensible | 2063.32 | 5.19091E-002 | 5.19091E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
| 33 | SPLIT TSW | Cooling | Sensible | 6399.96 | 0.44918 | 0.44918 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 34 | SPLIT TSW | Heating | Sensible | 2058.98 | 7.20384E-002 | 7.20384E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 35 | SPLIT TNW | Cooling | Sensible | 6418.17 | 0.45054 | 0.45054 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 36 | SPLIT TNW | Heating | Sensible | 1884.35 | 6.42056E-002 | 6.42056E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 37 | SPLIT TSE | Cooling | Sensible | 6087.21 | 0.42573 | 0.42573 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 38 | SPLIT TSE | Heating | Sensible | 2058.19 | 7.20031E-002 | 7.20031E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 39 | SPLIT TNE | Cooling | Sensible | 6105.24 | 0.42707 | 0.42707 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 40 | SPLIT TNE | Heating | Sensible | 1883.48 | 6.41666E-002 | 6.41666E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 41 | SPLIT TN1 | Cooling | Sensible | 5483.68 | 0.38047 | 0.38047 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 42 | SPLIT TN1 | Heating | Sensible | 1406.69 | 4.27783E-002 | 4.27783E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 43 | SPLIT TN2 | Cooling | Sensible | 5473.40 | 0.37970 | 0.37970 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 44 | SPLIT TN2 | Heating | Sensible | 1406.67 | 4.27771E-002 | 4.27771E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 45 | SPLIT TS1 | Cooling | Sensible | 5468.40 | 0.37933 | 0.37933 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 46 | SPLIT TS1 | Heating | Sensible | 1582.43 | 5.06611E-002 | 5.06611E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| 47 | SPLIT TS2 | Cooling | Sensible | 5458.14 | 0.37856 | 0.37856 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
| 48 | SPLIT TS2 | Heating | Sensible | 1582.40 | 5.06600E-002 | 5.06600E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 |
| Component Type | Component Name | Input Field Description | Value | |
| 1 | ZoneHVAC:EnergyRecoveryVentilator | G SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 2 | ZoneHVAC:EnergyRecoveryVentilator | G SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 3 | Fan:OnOff | G SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 4 | Fan:OnOff | G SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 5 | HeatExchanger:AirToAir:SensibleAndLatent | G SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 6 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.36449 |
| 7 | ZoneHVAC:EnergyRecoveryVentilator | G NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 8 | ZoneHVAC:EnergyRecoveryVentilator | G NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 9 | Fan:OnOff | G NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 10 | Fan:OnOff | G NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 11 | HeatExchanger:AirToAir:SensibleAndLatent | G NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 12 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.36376 |
| 13 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | OFFICE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.42546 |
| 14 | ZoneHVAC:EnergyRecoveryVentilator | G NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 15 | ZoneHVAC:EnergyRecoveryVentilator | G NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 16 | Fan:OnOff | G NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 17 | Fan:OnOff | G NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 18 | HeatExchanger:AirToAir:SensibleAndLatent | G NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 19 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.35042 |
| 20 | ZoneHVAC:EnergyRecoveryVentilator | G N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 21 | ZoneHVAC:EnergyRecoveryVentilator | G N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 22 | Fan:OnOff | G N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 23 | Fan:OnOff | G N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 24 | HeatExchanger:AirToAir:SensibleAndLatent | G N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 25 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.30524 |
| 26 | ZoneHVAC:EnergyRecoveryVentilator | G N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 27 | ZoneHVAC:EnergyRecoveryVentilator | G N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 28 | Fan:OnOff | G N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 29 | Fan:OnOff | G N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 30 | HeatExchanger:AirToAir:SensibleAndLatent | G N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 31 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.30501 |
| 32 | ZoneHVAC:EnergyRecoveryVentilator | G S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 33 | ZoneHVAC:EnergyRecoveryVentilator | G S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 34 | Fan:OnOff | G S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 35 | Fan:OnOff | G S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 36 | HeatExchanger:AirToAir:SensibleAndLatent | G S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 37 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.30653 |
| 38 | ZoneHVAC:EnergyRecoveryVentilator | G S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 39 | ZoneHVAC:EnergyRecoveryVentilator | G S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 40 | Fan:OnOff | G S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 41 | Fan:OnOff | G S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 42 | HeatExchanger:AirToAir:SensibleAndLatent | G S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 43 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | G S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.30949 |
| 44 | ZoneHVAC:EnergyRecoveryVentilator | M SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 45 | ZoneHVAC:EnergyRecoveryVentilator | M SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 46 | Fan:OnOff | M SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 47 | Fan:OnOff | M SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 48 | HeatExchanger:AirToAir:SensibleAndLatent | M SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 49 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.81145 |
| 50 | ZoneHVAC:EnergyRecoveryVentilator | M NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 51 | ZoneHVAC:EnergyRecoveryVentilator | M NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 52 | Fan:OnOff | M NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 53 | Fan:OnOff | M NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 54 | HeatExchanger:AirToAir:SensibleAndLatent | M NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 55 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.80985 |
| 56 | ZoneHVAC:EnergyRecoveryVentilator | M SE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 57 | ZoneHVAC:EnergyRecoveryVentilator | M SE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 58 | Fan:OnOff | M SE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 59 | Fan:OnOff | M SE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 60 | HeatExchanger:AirToAir:SensibleAndLatent | M SE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 61 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M SE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.77857 |
| 62 | ZoneHVAC:EnergyRecoveryVentilator | M NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 63 | ZoneHVAC:EnergyRecoveryVentilator | M NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 64 | Fan:OnOff | M NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 65 | Fan:OnOff | M NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 66 | HeatExchanger:AirToAir:SensibleAndLatent | M NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 67 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.77700 |
| 68 | ZoneHVAC:EnergyRecoveryVentilator | M N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 69 | ZoneHVAC:EnergyRecoveryVentilator | M N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 70 | Fan:OnOff | M N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 71 | Fan:OnOff | M N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 72 | HeatExchanger:AirToAir:SensibleAndLatent | M N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 73 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.66802 |
| 74 | ZoneHVAC:EnergyRecoveryVentilator | M N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 75 | ZoneHVAC:EnergyRecoveryVentilator | M N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 76 | Fan:OnOff | M N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 77 | Fan:OnOff | M N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 78 | HeatExchanger:AirToAir:SensibleAndLatent | M N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 79 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.66748 |
| 80 | ZoneHVAC:EnergyRecoveryVentilator | M S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 81 | ZoneHVAC:EnergyRecoveryVentilator | M S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 82 | Fan:OnOff | M S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 83 | Fan:OnOff | M S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 84 | HeatExchanger:AirToAir:SensibleAndLatent | M S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 85 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.67053 |
| 86 | ZoneHVAC:EnergyRecoveryVentilator | M S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 87 | ZoneHVAC:EnergyRecoveryVentilator | M S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 5.19091E-002 |
| 88 | Fan:OnOff | M S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 89 | Fan:OnOff | M S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 5.19091E-002 |
| 90 | HeatExchanger:AirToAir:SensibleAndLatent | M S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 5.19091E-002 |
| 91 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | M S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.66999 |
| 92 | ZoneHVAC:EnergyRecoveryVentilator | T SW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 93 | ZoneHVAC:EnergyRecoveryVentilator | T SW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 94 | Fan:OnOff | T SW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 95 | Fan:OnOff | T SW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 96 | HeatExchanger:AirToAir:SensibleAndLatent | T SW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 97 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T SW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.44918 |
| 98 | ZoneHVAC:EnergyRecoveryVentilator | T NW APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 99 | ZoneHVAC:EnergyRecoveryVentilator | T NW APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 100 | Fan:OnOff | T NW APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 101 | Fan:OnOff | T NW APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 102 | HeatExchanger:AirToAir:SensibleAndLatent | T NW APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 103 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T NW APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.45054 |
| 104 | ZoneHVAC:EnergyRecoveryVentilator | T SE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 105 | ZoneHVAC:EnergyRecoveryVentilator | T SE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 106 | Fan:OnOff | T SE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 107 | Fan:OnOff | T SE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 108 | HeatExchanger:AirToAir:SensibleAndLatent | T SE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 109 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T SE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.42573 |
| 110 | ZoneHVAC:EnergyRecoveryVentilator | T NE APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 111 | ZoneHVAC:EnergyRecoveryVentilator | T NE APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 112 | Fan:OnOff | T NE APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 113 | Fan:OnOff | T NE APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 114 | HeatExchanger:AirToAir:SensibleAndLatent | T NE APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 115 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T NE APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.42707 |
| 116 | ZoneHVAC:EnergyRecoveryVentilator | T N1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 117 | ZoneHVAC:EnergyRecoveryVentilator | T N1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 118 | Fan:OnOff | T N1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 119 | Fan:OnOff | T N1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 120 | HeatExchanger:AirToAir:SensibleAndLatent | T N1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 121 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T N1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.38047 |
| 122 | ZoneHVAC:EnergyRecoveryVentilator | T N2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 123 | ZoneHVAC:EnergyRecoveryVentilator | T N2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 124 | Fan:OnOff | T N2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 125 | Fan:OnOff | T N2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 126 | HeatExchanger:AirToAir:SensibleAndLatent | T N2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 127 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T N2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.37970 |
| 128 | ZoneHVAC:EnergyRecoveryVentilator | T S1 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 129 | ZoneHVAC:EnergyRecoveryVentilator | T S1 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 130 | Fan:OnOff | T S1 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 131 | Fan:OnOff | T S1 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 132 | HeatExchanger:AirToAir:SensibleAndLatent | T S1 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 133 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T S1 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.37933 |
| 134 | ZoneHVAC:EnergyRecoveryVentilator | T S2 APARTMENT ERV | User-Specified Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 135 | ZoneHVAC:EnergyRecoveryVentilator | T S2 APARTMENT ERV | User-Specified Exhaust Air Flow Rate [m3/s] | 2.59546E-002 |
| 136 | Fan:OnOff | T S2 APARTMENT ERV SUP FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 137 | Fan:OnOff | T S2 APARTMENT ERV EXH FAN | Design Size Maximum Flow Rate [m3/s] | 2.59546E-002 |
| 138 | HeatExchanger:AirToAir:SensibleAndLatent | T S2 APARTMENT OA HEAT EXCHANGER | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.59546E-002 |
| 139 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | T S2 APARTMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.37856 |
| 140 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.36449 |
| 141 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.36449 |
| 142 | AirLoopHVAC | SPLIT GSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.36449 |
| 143 | AirLoopHVAC | SPLIT GSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.36449 |
| 144 | AirLoopHVAC | SPLIT GSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.36449 |
| 145 | AirLoopHVAC | SPLIT GSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.36449 |
| 146 | AirLoopHVAC | SPLIT GSW | User Heating Air Flow Ratio [] | 1.00000 |
| 147 | AirLoopHVAC | SPLIT GSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 148 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.36376 |
| 149 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.36376 |
| 150 | AirLoopHVAC | SPLIT GNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.36376 |
| 151 | AirLoopHVAC | SPLIT GNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.36376 |
| 152 | AirLoopHVAC | SPLIT GNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.36376 |
| 153 | AirLoopHVAC | SPLIT GNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.36376 |
| 154 | AirLoopHVAC | SPLIT GNW | User Heating Air Flow Ratio [] | 1.00000 |
| 155 | AirLoopHVAC | SPLIT GNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 156 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.42546 |
| 157 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.42546 |
| 158 | AirLoopHVAC | SPLIT OFFICE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.42546 |
| 159 | AirLoopHVAC | SPLIT OFFICE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.42546 |
| 160 | AirLoopHVAC | SPLIT OFFICE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.42546 |
| 161 | AirLoopHVAC | SPLIT OFFICE | Adjusted Main Design Air Flow Rate [m3/s] | 0.42546 |
| 162 | AirLoopHVAC | SPLIT OFFICE | User Heating Air Flow Ratio [] | 1.00000 |
| 163 | AirLoopHVAC | SPLIT OFFICE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 164 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.35042 |
| 165 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.35042 |
| 166 | AirLoopHVAC | SPLIT GNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.35042 |
| 167 | AirLoopHVAC | SPLIT GNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.35042 |
| 168 | AirLoopHVAC | SPLIT GNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.35042 |
| 169 | AirLoopHVAC | SPLIT GNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.35042 |
| 170 | AirLoopHVAC | SPLIT GNE | User Heating Air Flow Ratio [] | 1.00000 |
| 171 | AirLoopHVAC | SPLIT GNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 172 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.30524 |
| 173 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.30524 |
| 174 | AirLoopHVAC | SPLIT GN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.30524 |
| 175 | AirLoopHVAC | SPLIT GN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.30524 |
| 176 | AirLoopHVAC | SPLIT GN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.30524 |
| 177 | AirLoopHVAC | SPLIT GN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.30524 |
| 178 | AirLoopHVAC | SPLIT GN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 179 | AirLoopHVAC | SPLIT GN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 180 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.30501 |
| 181 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.30501 |
| 182 | AirLoopHVAC | SPLIT GN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.30501 |
| 183 | AirLoopHVAC | SPLIT GN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.30501 |
| 184 | AirLoopHVAC | SPLIT GN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.30501 |
| 185 | AirLoopHVAC | SPLIT GN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.30501 |
| 186 | AirLoopHVAC | SPLIT GN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 187 | AirLoopHVAC | SPLIT GN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 188 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.30653 |
| 189 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.30653 |
| 190 | AirLoopHVAC | SPLIT GS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.30653 |
| 191 | AirLoopHVAC | SPLIT GS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.30653 |
| 192 | AirLoopHVAC | SPLIT GS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.30653 |
| 193 | AirLoopHVAC | SPLIT GS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.30653 |
| 194 | AirLoopHVAC | SPLIT GS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 195 | AirLoopHVAC | SPLIT GS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 196 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.30949 |
| 197 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.30949 |
| 198 | AirLoopHVAC | SPLIT GS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.30949 |
| 199 | AirLoopHVAC | SPLIT GS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.30949 |
| 200 | AirLoopHVAC | SPLIT GS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.30949 |
| 201 | AirLoopHVAC | SPLIT GS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.30949 |
| 202 | AirLoopHVAC | SPLIT GS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 203 | AirLoopHVAC | SPLIT GS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 204 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.81145 |
| 205 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.81145 |
| 206 | AirLoopHVAC | SPLIT MSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.81145 |
| 207 | AirLoopHVAC | SPLIT MSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.81145 |
| 208 | AirLoopHVAC | SPLIT MSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.81145 |
| 209 | AirLoopHVAC | SPLIT MSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.81145 |
| 210 | AirLoopHVAC | SPLIT MSW | User Heating Air Flow Ratio [] | 1.00000 |
| 211 | AirLoopHVAC | SPLIT MSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 212 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.80985 |
| 213 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.80985 |
| 214 | AirLoopHVAC | SPLIT MNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.80985 |
| 215 | AirLoopHVAC | SPLIT MNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.80985 |
| 216 | AirLoopHVAC | SPLIT MNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.80985 |
| 217 | AirLoopHVAC | SPLIT MNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.80985 |
| 218 | AirLoopHVAC | SPLIT MNW | User Heating Air Flow Ratio [] | 1.00000 |
| 219 | AirLoopHVAC | SPLIT MNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 220 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.77857 |
| 221 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.77857 |
| 222 | AirLoopHVAC | SPLIT MSE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.77857 |
| 223 | AirLoopHVAC | SPLIT MSE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.77857 |
| 224 | AirLoopHVAC | SPLIT MSE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.77857 |
| 225 | AirLoopHVAC | SPLIT MSE | Adjusted Main Design Air Flow Rate [m3/s] | 0.77857 |
| 226 | AirLoopHVAC | SPLIT MSE | User Heating Air Flow Ratio [] | 1.00000 |
| 227 | AirLoopHVAC | SPLIT MSE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 228 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.77700 |
| 229 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.77700 |
| 230 | AirLoopHVAC | SPLIT MNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.77700 |
| 231 | AirLoopHVAC | SPLIT MNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.77700 |
| 232 | AirLoopHVAC | SPLIT MNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.77700 |
| 233 | AirLoopHVAC | SPLIT MNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.77700 |
| 234 | AirLoopHVAC | SPLIT MNE | User Heating Air Flow Ratio [] | 1.00000 |
| 235 | AirLoopHVAC | SPLIT MNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 236 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.66802 |
| 237 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.66802 |
| 238 | AirLoopHVAC | SPLIT MN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.66802 |
| 239 | AirLoopHVAC | SPLIT MN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.66802 |
| 240 | AirLoopHVAC | SPLIT MN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.66802 |
| 241 | AirLoopHVAC | SPLIT MN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.66802 |
| 242 | AirLoopHVAC | SPLIT MN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 243 | AirLoopHVAC | SPLIT MN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 244 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.66748 |
| 245 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.66748 |
| 246 | AirLoopHVAC | SPLIT MN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.66748 |
| 247 | AirLoopHVAC | SPLIT MN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.66748 |
| 248 | AirLoopHVAC | SPLIT MN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.66748 |
| 249 | AirLoopHVAC | SPLIT MN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.66748 |
| 250 | AirLoopHVAC | SPLIT MN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 251 | AirLoopHVAC | SPLIT MN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 252 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.67053 |
| 253 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.67053 |
| 254 | AirLoopHVAC | SPLIT MS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.67053 |
| 255 | AirLoopHVAC | SPLIT MS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.67053 |
| 256 | AirLoopHVAC | SPLIT MS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.67053 |
| 257 | AirLoopHVAC | SPLIT MS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.67053 |
| 258 | AirLoopHVAC | SPLIT MS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 259 | AirLoopHVAC | SPLIT MS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 260 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.66999 |
| 261 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.66999 |
| 262 | AirLoopHVAC | SPLIT MS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.66999 |
| 263 | AirLoopHVAC | SPLIT MS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.66999 |
| 264 | AirLoopHVAC | SPLIT MS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.66999 |
| 265 | AirLoopHVAC | SPLIT MS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.66999 |
| 266 | AirLoopHVAC | SPLIT MS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 267 | AirLoopHVAC | SPLIT MS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 268 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.44918 |
| 269 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.44918 |
| 270 | AirLoopHVAC | SPLIT TSW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.44918 |
| 271 | AirLoopHVAC | SPLIT TSW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.44918 |
| 272 | AirLoopHVAC | SPLIT TSW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.44918 |
| 273 | AirLoopHVAC | SPLIT TSW | Adjusted Main Design Air Flow Rate [m3/s] | 0.44918 |
| 274 | AirLoopHVAC | SPLIT TSW | User Heating Air Flow Ratio [] | 1.00000 |
| 275 | AirLoopHVAC | SPLIT TSW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 276 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.45054 |
| 277 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.45054 |
| 278 | AirLoopHVAC | SPLIT TNW | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.45054 |
| 279 | AirLoopHVAC | SPLIT TNW | Adjusted Heating Design Air Flow Rate [m3/s] | 0.45054 |
| 280 | AirLoopHVAC | SPLIT TNW | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.45054 |
| 281 | AirLoopHVAC | SPLIT TNW | Adjusted Main Design Air Flow Rate [m3/s] | 0.45054 |
| 282 | AirLoopHVAC | SPLIT TNW | User Heating Air Flow Ratio [] | 1.00000 |
| 283 | AirLoopHVAC | SPLIT TNW | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 284 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.42573 |
| 285 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.42573 |
| 286 | AirLoopHVAC | SPLIT TSE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.42573 |
| 287 | AirLoopHVAC | SPLIT TSE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.42573 |
| 288 | AirLoopHVAC | SPLIT TSE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.42573 |
| 289 | AirLoopHVAC | SPLIT TSE | Adjusted Main Design Air Flow Rate [m3/s] | 0.42573 |
| 290 | AirLoopHVAC | SPLIT TSE | User Heating Air Flow Ratio [] | 1.00000 |
| 291 | AirLoopHVAC | SPLIT TSE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 292 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.42707 |
| 293 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.42707 |
| 294 | AirLoopHVAC | SPLIT TNE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.42707 |
| 295 | AirLoopHVAC | SPLIT TNE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.42707 |
| 296 | AirLoopHVAC | SPLIT TNE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.42707 |
| 297 | AirLoopHVAC | SPLIT TNE | Adjusted Main Design Air Flow Rate [m3/s] | 0.42707 |
| 298 | AirLoopHVAC | SPLIT TNE | User Heating Air Flow Ratio [] | 1.00000 |
| 299 | AirLoopHVAC | SPLIT TNE | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 300 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.38047 |
| 301 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.38047 |
| 302 | AirLoopHVAC | SPLIT TN1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.38047 |
| 303 | AirLoopHVAC | SPLIT TN1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.38047 |
| 304 | AirLoopHVAC | SPLIT TN1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.38047 |
| 305 | AirLoopHVAC | SPLIT TN1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.38047 |
| 306 | AirLoopHVAC | SPLIT TN1 | User Heating Air Flow Ratio [] | 1.00000 |
| 307 | AirLoopHVAC | SPLIT TN1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 308 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.37970 |
| 309 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.37970 |
| 310 | AirLoopHVAC | SPLIT TN2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.37970 |
| 311 | AirLoopHVAC | SPLIT TN2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.37970 |
| 312 | AirLoopHVAC | SPLIT TN2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.37970 |
| 313 | AirLoopHVAC | SPLIT TN2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.37970 |
| 314 | AirLoopHVAC | SPLIT TN2 | User Heating Air Flow Ratio [] | 1.00000 |
| 315 | AirLoopHVAC | SPLIT TN2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 316 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.37933 |
| 317 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.37933 |
| 318 | AirLoopHVAC | SPLIT TS1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.37933 |
| 319 | AirLoopHVAC | SPLIT TS1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.37933 |
| 320 | AirLoopHVAC | SPLIT TS1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.37933 |
| 321 | AirLoopHVAC | SPLIT TS1 | Adjusted Main Design Air Flow Rate [m3/s] | 0.37933 |
| 322 | AirLoopHVAC | SPLIT TS1 | User Heating Air Flow Ratio [] | 1.00000 |
| 323 | AirLoopHVAC | SPLIT TS1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 324 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.37856 |
| 325 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.37856 |
| 326 | AirLoopHVAC | SPLIT TS2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.37856 |
| 327 | AirLoopHVAC | SPLIT TS2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.37856 |
| 328 | AirLoopHVAC | SPLIT TS2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.37856 |
| 329 | AirLoopHVAC | SPLIT TS2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.37856 |
| 330 | AirLoopHVAC | SPLIT TS2 | User Heating Air Flow Ratio [] | 1.00000 |
| 331 | AirLoopHVAC | SPLIT TS2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
| 332 | AirLoopHVAC | SPLIT GSW | Design Supply Air Flow Rate [m3/s] | 0.36449 |
| 333 | AirLoopHVAC | SPLIT GNW | Design Supply Air Flow Rate [m3/s] | 0.36376 |
| 334 | AirLoopHVAC | SPLIT OFFICE | Design Supply Air Flow Rate [m3/s] | 0.42546 |
| 335 | AirLoopHVAC | SPLIT GNE | Design Supply Air Flow Rate [m3/s] | 0.35042 |
| 336 | AirLoopHVAC | SPLIT GN1 | Design Supply Air Flow Rate [m3/s] | 0.30524 |
| 337 | AirLoopHVAC | SPLIT GN2 | Design Supply Air Flow Rate [m3/s] | 0.30501 |
| 338 | AirLoopHVAC | SPLIT GS1 | Design Supply Air Flow Rate [m3/s] | 0.30653 |
| 339 | AirLoopHVAC | SPLIT GS2 | Design Supply Air Flow Rate [m3/s] | 0.30949 |
| 340 | AirLoopHVAC | SPLIT MSW | Design Supply Air Flow Rate [m3/s] | 0.81145 |
| 341 | AirLoopHVAC | SPLIT MNW | Design Supply Air Flow Rate [m3/s] | 0.80985 |
| 342 | AirLoopHVAC | SPLIT MSE | Design Supply Air Flow Rate [m3/s] | 0.77857 |
| 343 | AirLoopHVAC | SPLIT MNE | Design Supply Air Flow Rate [m3/s] | 0.77700 |
| 344 | AirLoopHVAC | SPLIT MN1 | Design Supply Air Flow Rate [m3/s] | 0.66802 |
| 345 | AirLoopHVAC | SPLIT MN2 | Design Supply Air Flow Rate [m3/s] | 0.66748 |
| 346 | AirLoopHVAC | SPLIT MS1 | Design Supply Air Flow Rate [m3/s] | 0.67053 |
| 347 | AirLoopHVAC | SPLIT MS2 | Design Supply Air Flow Rate [m3/s] | 0.66999 |
| 348 | AirLoopHVAC | SPLIT TSW | Design Supply Air Flow Rate [m3/s] | 0.44918 |
| 349 | AirLoopHVAC | SPLIT TNW | Design Supply Air Flow Rate [m3/s] | 0.45054 |
| 350 | AirLoopHVAC | SPLIT TSE | Design Supply Air Flow Rate [m3/s] | 0.42573 |
| 351 | AirLoopHVAC | SPLIT TNE | Design Supply Air Flow Rate [m3/s] | 0.42707 |
| 352 | AirLoopHVAC | SPLIT TN1 | Design Supply Air Flow Rate [m3/s] | 0.38047 |
| 353 | AirLoopHVAC | SPLIT TN2 | Design Supply Air Flow Rate [m3/s] | 0.37970 |
| 354 | AirLoopHVAC | SPLIT TS1 | Design Supply Air Flow Rate [m3/s] | 0.37933 |
| 355 | AirLoopHVAC | SPLIT TS2 | Design Supply Air Flow Rate [m3/s] | 0.37856 |
| 356 | Controller:OutdoorAir | SPLIT GSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.36449 |
| 357 | Controller:OutdoorAir | SPLIT GSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 358 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.36449 |
| 359 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.36449 |
| 360 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.36449 |
| 361 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.36449 |
| 362 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6512.19664 |
| 363 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 4363.17175 |
| 364 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 365 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 6512.19664 |
| 366 | AirLoopHVAC:UnitarySystem | SPLIT GSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 367 | Fan:OnOff | SPLIT GSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.36449 |
| 368 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.36449 |
| 369 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6512.19664 |
| 370 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80064 |
| 371 | Coil:Heating:DX:SingleSpeed | SPLIT GSW HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.36449 |
| 372 | Coil:Heating:DX:SingleSpeed | SPLIT GSW HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 6512.19664 |
| 373 | Coil:Heating:Electric | SPLIT GSW_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 6512.19664 |
| 374 | Controller:OutdoorAir | SPLIT GNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.36376 |
| 375 | Controller:OutdoorAir | SPLIT GNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 376 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.36376 |
| 377 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.36376 |
| 378 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.36376 |
| 379 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.36376 |
| 380 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6457.75745 |
| 381 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 4326.69749 |
| 382 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 383 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 6457.75745 |
| 384 | AirLoopHVAC:UnitarySystem | SPLIT GNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 385 | Fan:OnOff | SPLIT GNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.36376 |
| 386 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.36376 |
| 387 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6457.75745 |
| 388 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80082 |
| 389 | Coil:Heating:DX:SingleSpeed | SPLIT GNW HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.36376 |
| 390 | Coil:Heating:DX:SingleSpeed | SPLIT GNW HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 6457.75745 |
| 391 | Coil:Heating:Electric | SPLIT GNW_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 6457.75745 |
| 392 | Controller:OutdoorAir | SPLIT OFFICE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.42546 |
| 393 | Controller:OutdoorAir | SPLIT OFFICE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 3.81060E-002 |
| 394 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.42546 |
| 395 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.42546 |
| 396 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.42546 |
| 397 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.42546 |
| 398 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7362.06093 |
| 399 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 4932.58082 |
| 400 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 401 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 7362.06093 |
| 402 | AirLoopHVAC:UnitarySystem | SPLIT OFFICE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 403 | Fan:OnOff | SPLIT OFFICE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.42546 |
| 404 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.42546 |
| 405 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7362.06093 |
| 406 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80071 |
| 407 | Coil:Heating:DX:SingleSpeed | SPLIT OFFICE HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.42546 |
| 408 | Coil:Heating:DX:SingleSpeed | SPLIT OFFICE HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 7362.06093 |
| 409 | Coil:Heating:Electric | SPLIT OFFICE_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 7362.06093 |
| 410 | Controller:OutdoorAir | SPLIT GNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.35042 |
| 411 | Controller:OutdoorAir | SPLIT GNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 412 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.35042 |
| 413 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.35042 |
| 414 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.35042 |
| 415 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.35042 |
| 416 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6243.27771 |
| 417 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 4182.99607 |
| 418 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 419 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 6243.27771 |
| 420 | AirLoopHVAC:UnitarySystem | SPLIT GNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 421 | Fan:OnOff | SPLIT GNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.35042 |
| 422 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.35042 |
| 423 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6243.27771 |
| 424 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80059 |
| 425 | Coil:Heating:DX:SingleSpeed | SPLIT GNE HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.35042 |
| 426 | Coil:Heating:DX:SingleSpeed | SPLIT GNE HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 6243.27771 |
| 427 | Coil:Heating:Electric | SPLIT GNE_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 6243.27771 |
| 428 | Controller:OutdoorAir | SPLIT GN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.30524 |
| 429 | Controller:OutdoorAir | SPLIT GN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 430 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.30524 |
| 431 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.30524 |
| 432 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.30524 |
| 433 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.30524 |
| 434 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5512.09407 |
| 435 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3693.10302 |
| 436 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 437 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5512.09407 |
| 438 | AirLoopHVAC:UnitarySystem | SPLIT GN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 439 | Fan:OnOff | SPLIT GN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.30524 |
| 440 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.30524 |
| 441 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5512.09407 |
| 442 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80002 |
| 443 | Coil:Heating:DX:SingleSpeed | SPLIT GN1 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.30524 |
| 444 | Coil:Heating:DX:SingleSpeed | SPLIT GN1 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5512.09407 |
| 445 | Coil:Heating:Electric | SPLIT GN1_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5512.09407 |
| 446 | Controller:OutdoorAir | SPLIT GN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.30501 |
| 447 | Controller:OutdoorAir | SPLIT GN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 448 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.30501 |
| 449 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.30501 |
| 450 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.30501 |
| 451 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.30501 |
| 452 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5508.34796 |
| 453 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3690.59313 |
| 454 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 455 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5508.34796 |
| 456 | AirLoopHVAC:UnitarySystem | SPLIT GN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 457 | Fan:OnOff | SPLIT GN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.30501 |
| 458 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.30501 |
| 459 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5508.34796 |
| 460 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80100 |
| 461 | Coil:Heating:DX:SingleSpeed | SPLIT GN2 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.30501 |
| 462 | Coil:Heating:DX:SingleSpeed | SPLIT GN2 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5508.34796 |
| 463 | Coil:Heating:Electric | SPLIT GN2_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5508.34796 |
| 464 | Controller:OutdoorAir | SPLIT GS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.30653 |
| 465 | Controller:OutdoorAir | SPLIT GS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 466 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.30653 |
| 467 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.30653 |
| 468 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.30653 |
| 469 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.30653 |
| 470 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5600.84469 |
| 471 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3752.56594 |
| 472 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 473 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5600.84469 |
| 474 | AirLoopHVAC:UnitarySystem | SPLIT GS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 475 | Fan:OnOff | SPLIT GS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.30653 |
| 476 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.30653 |
| 477 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5600.84469 |
| 478 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80008 |
| 479 | Coil:Heating:DX:SingleSpeed | SPLIT GS1 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.30653 |
| 480 | Coil:Heating:DX:SingleSpeed | SPLIT GS1 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5600.84469 |
| 481 | Coil:Heating:Electric | SPLIT GS1_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5600.84469 |
| 482 | Controller:OutdoorAir | SPLIT GS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.30949 |
| 483 | Controller:OutdoorAir | SPLIT GS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 484 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.30949 |
| 485 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.30949 |
| 486 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.30949 |
| 487 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.30949 |
| 488 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 5649.03927 |
| 489 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 3784.85631 |
| 490 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 491 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 5649.03927 |
| 492 | AirLoopHVAC:UnitarySystem | SPLIT GS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 493 | Fan:OnOff | SPLIT GS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.30949 |
| 494 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.30949 |
| 495 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 5649.03927 |
| 496 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80043 |
| 497 | Coil:Heating:DX:SingleSpeed | SPLIT GS2 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.30949 |
| 498 | Coil:Heating:DX:SingleSpeed | SPLIT GS2 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 5649.03927 |
| 499 | Coil:Heating:Electric | SPLIT GS2_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 5649.03927 |
| 500 | Controller:OutdoorAir | SPLIT MSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.81145 |
| 501 | Controller:OutdoorAir | SPLIT MSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 502 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.81145 |
| 503 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.81145 |
| 504 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.81145 |
| 505 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.81145 |
| 506 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 14359.57128 |
| 507 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9620.91276 |
| 508 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 509 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 14359.57128 |
| 510 | AirLoopHVAC:UnitarySystem | SPLIT MSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 511 | Fan:OnOff | SPLIT MSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.81145 |
| 512 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.81145 |
| 513 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 14359.57128 |
| 514 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80092 |
| 515 | Coil:Heating:DX:SingleSpeed | SPLIT MSW HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.81145 |
| 516 | Coil:Heating:DX:SingleSpeed | SPLIT MSW HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 14359.57128 |
| 517 | Coil:Heating:Electric | SPLIT MSW_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 14359.57128 |
| 518 | Controller:OutdoorAir | SPLIT MNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.80985 |
| 519 | Controller:OutdoorAir | SPLIT MNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 520 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.80985 |
| 521 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.80985 |
| 522 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.80985 |
| 523 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.80985 |
| 524 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 14260.49930 |
| 525 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9554.53453 |
| 526 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 527 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 14260.49930 |
| 528 | AirLoopHVAC:UnitarySystem | SPLIT MNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 529 | Fan:OnOff | SPLIT MNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.80985 |
| 530 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.80985 |
| 531 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 14260.49930 |
| 532 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80062 |
| 533 | Coil:Heating:DX:SingleSpeed | SPLIT MNW HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.80985 |
| 534 | Coil:Heating:DX:SingleSpeed | SPLIT MNW HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 14260.49930 |
| 535 | Coil:Heating:Electric | SPLIT MNW_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 14260.49930 |
| 536 | Controller:OutdoorAir | SPLIT MSE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.77857 |
| 537 | Controller:OutdoorAir | SPLIT MSE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 538 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.77857 |
| 539 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.77857 |
| 540 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.77857 |
| 541 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.77857 |
| 542 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 13838.85858 |
| 543 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9272.03525 |
| 544 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 545 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 13838.85858 |
| 546 | AirLoopHVAC:UnitarySystem | SPLIT MSE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 547 | Fan:OnOff | SPLIT MSE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.77857 |
| 548 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.77857 |
| 549 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 13838.85858 |
| 550 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80040 |
| 551 | Coil:Heating:DX:SingleSpeed | SPLIT MSE HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.77857 |
| 552 | Coil:Heating:DX:SingleSpeed | SPLIT MSE HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 13838.85858 |
| 553 | Coil:Heating:Electric | SPLIT MSE_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 13838.85858 |
| 554 | Controller:OutdoorAir | SPLIT MNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.77700 |
| 555 | Controller:OutdoorAir | SPLIT MNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 556 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.77700 |
| 557 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.77700 |
| 558 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.77700 |
| 559 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.77700 |
| 560 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 13731.43675 |
| 561 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 9200.06262 |
| 562 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 563 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 13731.43675 |
| 564 | AirLoopHVAC:UnitarySystem | SPLIT MNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 565 | Fan:OnOff | SPLIT MNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.77700 |
| 566 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.77700 |
| 567 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 13731.43675 |
| 568 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80038 |
| 569 | Coil:Heating:DX:SingleSpeed | SPLIT MNE HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.77700 |
| 570 | Coil:Heating:DX:SingleSpeed | SPLIT MNE HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 13731.43675 |
| 571 | Coil:Heating:Electric | SPLIT MNE_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 13731.43675 |
| 572 | Controller:OutdoorAir | SPLIT MN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.66802 |
| 573 | Controller:OutdoorAir | SPLIT MN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 574 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.66802 |
| 575 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.66802 |
| 576 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.66802 |
| 577 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.66802 |
| 578 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 11967.74999 |
| 579 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8018.39250 |
| 580 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 581 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 11967.74999 |
| 582 | AirLoopHVAC:UnitarySystem | SPLIT MN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 583 | Fan:OnOff | SPLIT MN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.66802 |
| 584 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.66802 |
| 585 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 11967.74999 |
| 586 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80071 |
| 587 | Coil:Heating:DX:SingleSpeed | SPLIT MN1 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.66802 |
| 588 | Coil:Heating:DX:SingleSpeed | SPLIT MN1 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 11967.74999 |
| 589 | Coil:Heating:Electric | SPLIT MN1_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 11967.74999 |
| 590 | Controller:OutdoorAir | SPLIT MN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.66748 |
| 591 | Controller:OutdoorAir | SPLIT MN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 592 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.66748 |
| 593 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.66748 |
| 594 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.66748 |
| 595 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.66748 |
| 596 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 11959.05650 |
| 597 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8012.56785 |
| 598 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 599 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 11959.05650 |
| 600 | AirLoopHVAC:UnitarySystem | SPLIT MN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 601 | Fan:OnOff | SPLIT MN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.66748 |
| 602 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.66748 |
| 603 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 11959.05650 |
| 604 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80068 |
| 605 | Coil:Heating:DX:SingleSpeed | SPLIT MN2 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.66748 |
| 606 | Coil:Heating:DX:SingleSpeed | SPLIT MN2 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 11959.05650 |
| 607 | Coil:Heating:Electric | SPLIT MN2_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 11959.05650 |
| 608 | Controller:OutdoorAir | SPLIT MS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.67053 |
| 609 | Controller:OutdoorAir | SPLIT MS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 610 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.67053 |
| 611 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.67053 |
| 612 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.67053 |
| 613 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.67053 |
| 614 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 12132.36683 |
| 615 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8128.68578 |
| 616 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 617 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 12132.36683 |
| 618 | AirLoopHVAC:UnitarySystem | SPLIT MS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 619 | Fan:OnOff | SPLIT MS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.67053 |
| 620 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.67053 |
| 621 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 12132.36683 |
| 622 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80036 |
| 623 | Coil:Heating:DX:SingleSpeed | SPLIT MS1 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.67053 |
| 624 | Coil:Heating:DX:SingleSpeed | SPLIT MS1 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 12132.36683 |
| 625 | Coil:Heating:Electric | SPLIT MS1_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 12132.36683 |
| 626 | Controller:OutdoorAir | SPLIT MS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.66999 |
| 627 | Controller:OutdoorAir | SPLIT MS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 5.19091E-002 |
| 628 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.66999 |
| 629 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.66999 |
| 630 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.66999 |
| 631 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.66999 |
| 632 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 12123.75931 |
| 633 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 8122.91874 |
| 634 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 635 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 12123.75931 |
| 636 | AirLoopHVAC:UnitarySystem | SPLIT MS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 637 | Fan:OnOff | SPLIT MS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.66999 |
| 638 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.66999 |
| 639 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 12123.75931 |
| 640 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80033 |
| 641 | Coil:Heating:DX:SingleSpeed | SPLIT MS2 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.66999 |
| 642 | Coil:Heating:DX:SingleSpeed | SPLIT MS2 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 12123.75931 |
| 643 | Coil:Heating:Electric | SPLIT MS2_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 12123.75931 |
| 644 | Controller:OutdoorAir | SPLIT TSW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.44918 |
| 645 | Controller:OutdoorAir | SPLIT TSW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 646 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.44918 |
| 647 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.44918 |
| 648 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.44918 |
| 649 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.44918 |
| 650 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7873.36211 |
| 651 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 5275.15261 |
| 652 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 653 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 7873.36211 |
| 654 | AirLoopHVAC:UnitarySystem | SPLIT TSW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 655 | Fan:OnOff | SPLIT TSW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.44918 |
| 656 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.44918 |
| 657 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7873.36211 |
| 658 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80021 |
| 659 | Coil:Heating:DX:SingleSpeed | SPLIT TSW HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.44918 |
| 660 | Coil:Heating:DX:SingleSpeed | SPLIT TSW HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 7873.36211 |
| 661 | Coil:Heating:Electric | SPLIT TSW_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 7873.36211 |
| 662 | Controller:OutdoorAir | SPLIT TNW_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.45054 |
| 663 | Controller:OutdoorAir | SPLIT TNW_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 664 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.45054 |
| 665 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.45054 |
| 666 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.45054 |
| 667 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.45054 |
| 668 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7871.04818 |
| 669 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 5273.60228 |
| 670 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 671 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 7871.04818 |
| 672 | AirLoopHVAC:UnitarySystem | SPLIT TNW_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 673 | Fan:OnOff | SPLIT TNW SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.45054 |
| 674 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.45054 |
| 675 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7871.04818 |
| 676 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80037 |
| 677 | Coil:Heating:DX:SingleSpeed | SPLIT TNW HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.45054 |
| 678 | Coil:Heating:DX:SingleSpeed | SPLIT TNW HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 7871.04818 |
| 679 | Coil:Heating:Electric | SPLIT TNW_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 7871.04818 |
| 680 | Controller:OutdoorAir | SPLIT TSE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.42573 |
| 681 | Controller:OutdoorAir | SPLIT TSE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 682 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.42573 |
| 683 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.42573 |
| 684 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.42573 |
| 685 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.42573 |
| 686 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7495.58061 |
| 687 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 5022.03901 |
| 688 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 689 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 7495.58061 |
| 690 | AirLoopHVAC:UnitarySystem | SPLIT TSE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 691 | Fan:OnOff | SPLIT TSE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.42573 |
| 692 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.42573 |
| 693 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7495.58061 |
| 694 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80067 |
| 695 | Coil:Heating:DX:SingleSpeed | SPLIT TSE HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.42573 |
| 696 | Coil:Heating:DX:SingleSpeed | SPLIT TSE HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 7495.58061 |
| 697 | Coil:Heating:Electric | SPLIT TSE_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 7495.58061 |
| 698 | Controller:OutdoorAir | SPLIT TNE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.42707 |
| 699 | Controller:OutdoorAir | SPLIT TNE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 700 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.42707 |
| 701 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.42707 |
| 702 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.42707 |
| 703 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.42707 |
| 704 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 7490.68559 |
| 705 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 5018.75934 |
| 706 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 707 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 7490.68559 |
| 708 | AirLoopHVAC:UnitarySystem | SPLIT TNE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 709 | Fan:OnOff | SPLIT TNE SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.42707 |
| 710 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.42707 |
| 711 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 7490.68559 |
| 712 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80099 |
| 713 | Coil:Heating:DX:SingleSpeed | SPLIT TNE HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.42707 |
| 714 | Coil:Heating:DX:SingleSpeed | SPLIT TNE HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 7490.68559 |
| 715 | Coil:Heating:Electric | SPLIT TNE_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 7490.68559 |
| 716 | Controller:OutdoorAir | SPLIT TN1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.38047 |
| 717 | Controller:OutdoorAir | SPLIT TN1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 718 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.38047 |
| 719 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.38047 |
| 720 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.38047 |
| 721 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.38047 |
| 722 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6728.07791 |
| 723 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 4507.81220 |
| 724 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 725 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 6728.07791 |
| 726 | AirLoopHVAC:UnitarySystem | SPLIT TN1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 727 | Fan:OnOff | SPLIT TN1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.38047 |
| 728 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.38047 |
| 729 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6728.07791 |
| 730 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80016 |
| 731 | Coil:Heating:DX:SingleSpeed | SPLIT TN1 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.38047 |
| 732 | Coil:Heating:DX:SingleSpeed | SPLIT TN1 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 6728.07791 |
| 733 | Coil:Heating:Electric | SPLIT TN1_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 6728.07791 |
| 734 | Controller:OutdoorAir | SPLIT TN2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.37970 |
| 735 | Controller:OutdoorAir | SPLIT TN2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 736 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.37970 |
| 737 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.37970 |
| 738 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.37970 |
| 739 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.37970 |
| 740 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6715.58154 |
| 741 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 4499.43963 |
| 742 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 743 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 6715.58154 |
| 744 | AirLoopHVAC:UnitarySystem | SPLIT TN2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 745 | Fan:OnOff | SPLIT TN2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.37970 |
| 746 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.37970 |
| 747 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6715.58154 |
| 748 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80010 |
| 749 | Coil:Heating:DX:SingleSpeed | SPLIT TN2 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.37970 |
| 750 | Coil:Heating:DX:SingleSpeed | SPLIT TN2 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 6715.58154 |
| 751 | Coil:Heating:Electric | SPLIT TN2_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 6715.58154 |
| 752 | Controller:OutdoorAir | SPLIT TS1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.37933 |
| 753 | Controller:OutdoorAir | SPLIT TS1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 754 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.37933 |
| 755 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.37933 |
| 756 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.37933 |
| 757 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.37933 |
| 758 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6742.38441 |
| 759 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 4517.39755 |
| 760 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 761 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 6742.38441 |
| 762 | AirLoopHVAC:UnitarySystem | SPLIT TS1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 763 | Fan:OnOff | SPLIT TS1 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.37933 |
| 764 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.37933 |
| 765 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6742.38441 |
| 766 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80040 |
| 767 | Coil:Heating:DX:SingleSpeed | SPLIT TS1 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.37933 |
| 768 | Coil:Heating:DX:SingleSpeed | SPLIT TS1 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 6742.38441 |
| 769 | Coil:Heating:Electric | SPLIT TS1_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 6742.38441 |
| 770 | Controller:OutdoorAir | SPLIT TS2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.37856 |
| 771 | Controller:OutdoorAir | SPLIT TS2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.59546E-002 |
| 772 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.37856 |
| 773 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.37856 |
| 774 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.37856 |
| 775 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.37856 |
| 776 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Nominal Cooling Capacity [W] | 6730.01594 |
| 777 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 4509.11068 |
| 778 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
| 779 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | User-Specified Supplemental Heating Coil Nominal Capacity [W] | 6730.01594 |
| 780 | AirLoopHVAC:UnitarySystem | SPLIT TS2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
| 781 | Fan:OnOff | SPLIT TS2 SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.37856 |
| 782 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 HP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.37856 |
| 783 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 HP COOLING COIL | Design Size Gross Rated Total Cooling Capacity [W] | 6730.01594 |
| 784 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 HP COOLING COIL | Design Size Gross Rated Sensible Heat Ratio | 0.80033 |
| 785 | Coil:Heating:DX:SingleSpeed | SPLIT TS2 HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.37856 |
| 786 | Coil:Heating:DX:SingleSpeed | SPLIT TS2 HEATING COIL | Design Size Gross Rated Heating Capacity [W] | 6730.01594 |
| 787 | Coil:Heating:Electric | SPLIT TS2_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 6730.01594 |
| 788 | PlantLoop | SWHSYS1 | Maximum Loop Flow Rate [m3/s] | 1.13460E-004 |
| 789 | PlantLoop | SWHSYS1 | Plant Loop Volume [m3] | 1.36152E-002 |
| 790 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Flow Rate [m3/s] | 1.13460E-004 |
| 791 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Power Consumption [W] | 14.49330 |
| 792 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | Use Side Design Flow Rate [m3/s] | 1.13460E-004 |
| Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER User {Btu/W-h} | SEER Standard {Btu/W-h} | IEER {Btu/W-h} | |
| 1 | Coil:Cooling:DX:SingleSpeed | SPLIT GSW HP COOLING COIL | 6226.2 | 3.11 | 10.63 | 11.05 | 10.45 | 10.43 |
| 2 | Coil:Cooling:DX:SingleSpeed | SPLIT GNW HP COOLING COIL | 6172.4 | 3.11 | 10.61 | 11.04 | 10.44 | 10.41 |
| 3 | Coil:Cooling:DX:SingleSpeed | SPLIT OFFICE HP COOLING COIL | 7028.4 | 3.10 | 10.56 | 10.98 | 10.39 | 10.34 |
| 4 | Coil:Cooling:DX:SingleSpeed | SPLIT GNE HP COOLING COIL | 5968.4 | 3.11 | 10.62 | 11.04 | 10.45 | 10.42 |
| 5 | Coil:Cooling:DX:SingleSpeed | SPLIT GN1 HP COOLING COIL | 5272.6 | 3.12 | 10.65 | 11.07 | 10.47 | 10.46 |
| 6 | Coil:Cooling:DX:SingleSpeed | SPLIT GN2 HP COOLING COIL | 5269.0 | 3.12 | 10.65 | 11.07 | 10.48 | 10.46 |
| 7 | Coil:Cooling:DX:SingleSpeed | SPLIT GS1 HP COOLING COIL | 5360.3 | 3.13 | 10.67 | 11.10 | 10.50 | 10.49 |
| 8 | Coil:Cooling:DX:SingleSpeed | SPLIT GS2 HP COOLING COIL | 5406.2 | 3.13 | 10.67 | 11.10 | 10.50 | 10.49 |
| 9 | Coil:Cooling:DX:SingleSpeed | SPLIT MSW HP COOLING COIL | 13723.1 | 3.11 | 10.61 | 11.03 | 10.43 | 10.40 |
| 10 | Coil:Cooling:DX:SingleSpeed | SPLIT MNW HP COOLING COIL | 13625.3 | 3.11 | 10.60 | 11.02 | 10.42 | 10.39 |
| 11 | Coil:Cooling:DX:SingleSpeed | SPLIT MSE HP COOLING COIL | 13228.1 | 3.11 | 10.61 | 11.04 | 10.44 | 10.41 |
| 12 | Coil:Cooling:DX:SingleSpeed | SPLIT MNE HP COOLING COIL | 13122.0 | 3.11 | 10.60 | 11.03 | 10.43 | 10.40 |
| 13 | Coil:Cooling:DX:SingleSpeed | SPLIT MN1 HP COOLING COIL | 11443.7 | 3.12 | 10.63 | 11.06 | 10.46 | 10.44 |
| 14 | Coil:Cooling:DX:SingleSpeed | SPLIT MN2 HP COOLING COIL | 11435.4 | 3.12 | 10.63 | 11.06 | 10.46 | 10.44 |
| 15 | Coil:Cooling:DX:SingleSpeed | SPLIT MS1 HP COOLING COIL | 11606.2 | 3.12 | 10.65 | 11.08 | 10.48 | 10.47 |
| 16 | Coil:Cooling:DX:SingleSpeed | SPLIT MS2 HP COOLING COIL | 11598.1 | 3.12 | 10.65 | 11.08 | 10.48 | 10.47 |
| 17 | Coil:Cooling:DX:SingleSpeed | SPLIT TSW HP COOLING COIL | 7521.1 | 3.10 | 10.59 | 11.01 | 10.41 | 10.37 |
| 18 | Coil:Cooling:DX:SingleSpeed | SPLIT TNW HP COOLING COIL | 7517.7 | 3.10 | 10.58 | 11.00 | 10.41 | 10.36 |
| 19 | Coil:Cooling:DX:SingleSpeed | SPLIT TSE HP COOLING COIL | 7161.7 | 3.11 | 10.60 | 11.02 | 10.42 | 10.39 |
| 20 | Coil:Cooling:DX:SingleSpeed | SPLIT TNE HP COOLING COIL | 7155.7 | 3.10 | 10.59 | 11.01 | 10.42 | 10.38 |
| 21 | Coil:Cooling:DX:SingleSpeed | SPLIT TN1 HP COOLING COIL | 6429.6 | 3.11 | 10.60 | 11.03 | 10.43 | 10.40 |
| 22 | Coil:Cooling:DX:SingleSpeed | SPLIT TN2 HP COOLING COIL | 6417.7 | 3.11 | 10.61 | 11.03 | 10.43 | 10.40 |
| 23 | Coil:Cooling:DX:SingleSpeed | SPLIT TS1 HP COOLING COIL | 6444.8 | 3.11 | 10.61 | 11.04 | 10.44 | 10.41 |
| 24 | Coil:Cooling:DX:SingleSpeed | SPLIT TS2 HP COOLING COIL | 6433.1 | 3.11 | 10.62 | 11.04 | 10.44 | 10.41 |
| Component Type | Component Name | High Temperature Heating (net) Rating Capacity {W} | Low Temperature Heating (net) Rating Capacity {W} | HSPF {Btu/W-h} | Region Number | |
| 1 | Coil:Heating:DX:SingleSpeed | SPLIT GSW HEATING COIL | 6802.0 | 3778.4 | 8.07 | 4 |
| 2 | Coil:Heating:DX:SingleSpeed | SPLIT GNW HEATING COIL | 6746.9 | 3748.6 | 8.07 | 4 |
| 3 | Coil:Heating:DX:SingleSpeed | SPLIT OFFICE HEATING COIL | 7700.0 | 4281.8 | 8.10 | 4 |
| 4 | Coil:Heating:DX:SingleSpeed | SPLIT GNE HEATING COIL | 6521.8 | 3623.1 | 8.15 | 4 |
| 5 | Coil:Heating:DX:SingleSpeed | SPLIT GN1 HEATING COIL | 5754.8 | 3195.6 | 8.10 | 4 |
| 6 | Coil:Heating:DX:SingleSpeed | SPLIT GN2 HEATING COIL | 5750.9 | 3193.4 | 8.10 | 4 |
| 7 | Coil:Heating:DX:SingleSpeed | SPLIT GS1 HEATING COIL | 5844.7 | 3244.2 | 8.11 | 4 |
| 8 | Coil:Heating:DX:SingleSpeed | SPLIT GS2 HEATING COIL | 5895.2 | 3272.4 | 8.12 | 4 |
| 9 | Coil:Heating:DX:SingleSpeed | SPLIT MSW HEATING COIL | 15004.5 | 8337.4 | 8.11 | 4 |
| 10 | Coil:Heating:DX:SingleSpeed | SPLIT MNW HEATING COIL | 14904.0 | 8283.0 | 8.10 | 4 |
| 11 | Coil:Heating:DX:SingleSpeed | SPLIT MSE HEATING COIL | 14457.7 | 8032.4 | 8.09 | 4 |
| 12 | Coil:Heating:DX:SingleSpeed | SPLIT MNE HEATING COIL | 14348.9 | 7973.5 | 8.09 | 4 |
| 13 | Coil:Heating:DX:SingleSpeed | SPLIT MN1 HEATING COIL | 12498.8 | 6942.3 | 8.13 | 4 |
| 14 | Coil:Heating:DX:SingleSpeed | SPLIT MN2 HEATING COIL | 12489.7 | 6937.2 | 8.13 | 4 |
| 15 | Coil:Heating:DX:SingleSpeed | SPLIT MS1 HEATING COIL | 12665.6 | 7032.6 | 8.15 | 4 |
| 16 | Coil:Heating:DX:SingleSpeed | SPLIT MS2 HEATING COIL | 12656.6 | 7027.6 | 8.15 | 4 |
| 17 | Coil:Heating:DX:SingleSpeed | SPLIT TSW HEATING COIL | 8230.3 | 4574.7 | 8.07 | 4 |
| 18 | Coil:Heating:DX:SingleSpeed | SPLIT TNW HEATING COIL | 8229.0 | 4574.5 | 8.06 | 4 |
| 19 | Coil:Heating:DX:SingleSpeed | SPLIT TSE HEATING COIL | 7833.9 | 4353.7 | 8.12 | 4 |
| 20 | Coil:Heating:DX:SingleSpeed | SPLIT TNE HEATING COIL | 7830.0 | 4352.1 | 8.12 | 4 |
| 21 | Coil:Heating:DX:SingleSpeed | SPLIT TN1 HEATING COIL | 7030.5 | 3906.6 | 8.08 | 4 |
| 22 | Coil:Heating:DX:SingleSpeed | SPLIT TN2 HEATING COIL | 7017.3 | 3899.3 | 8.08 | 4 |
| 23 | Coil:Heating:DX:SingleSpeed | SPLIT TS1 HEATING COIL | 7043.9 | 3913.4 | 8.08 | 4 |
| 24 | Coil:Heating:DX:SingleSpeed | SPLIT TS2 HEATING COIL | 7030.9 | 3906.2 | 8.08 | 4 |
| Zone Name | # Surfaces | |
| 1 | G SW APARTMENT | 9 |
| 2 | G NW APARTMENT | 9 |
| 3 | OFFICE | 9 |
| 4 | G NE APARTMENT | 9 |
| 5 | G N1 APARTMENT | 8 |
| 6 | G N2 APARTMENT | 8 |
| 7 | G S1 APARTMENT | 8 |
| 8 | G S2 APARTMENT | 8 |
| 9 | M SW APARTMENT | 9 |
| 10 | M NW APARTMENT | 9 |
| 11 | M SE APARTMENT | 9 |
| 12 | M NE APARTMENT | 9 |
| 13 | M N1 APARTMENT | 8 |
| 14 | M N2 APARTMENT | 8 |
| 15 | M S1 APARTMENT | 8 |
| 16 | M S2 APARTMENT | 8 |
| 17 | T SW APARTMENT | 9 |
| 18 | T NW APARTMENT | 9 |
| 19 | T SE APARTMENT | 9 |
| 20 | T NE APARTMENT | 9 |
| 21 | T N1 APARTMENT | 8 |
| 22 | T N2 APARTMENT | 8 |
| 23 | T S1 APARTMENT | 8 |
| 24 | T S2 APARTMENT | 8 |
| 25 | T CORRIDOR | 13 |
| 26 | G CORRIDOR | 13 |
| 27 | M CORRIDOR | 13 |
| Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
| 1 | G SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 1.154 | 0.984 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 2 | GWINDOW1 S SWA | Window | G SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 3 | G WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 1.154 | 0.984 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 4 | GWINDOW1 W SWA | Window | G WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 5 | G NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 6 | G EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 7 | G GFLOOR SWA | Floor | CTF - ConductionTransferFunction | GGFLOORSWA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 8 | G CEILIN SWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 9 | G INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 10 | G NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 1.154 | 0.984 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 11 | GWINDOW1 N NWA | Window | G NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 12 | G WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 1.154 | 0.984 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 13 | GWINDOW1 W NWA | Window | G WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 14 | G SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 15 | G EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 16 | G GFLOOR NWA | Floor | CTF - ConductionTransferFunction | GGFLOORNWA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 17 | G CEILIN NWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 18 | G INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 19 | G SWALL SEA | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.154 | 0.984 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 20 | GWINDOW1 S SEA | Window | G SWALL SEA | Window5 Detailed Fenestration | NONRESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 21 | G EWALL SEA | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.154 | 0.984 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 22 | GWINDOW1 E SEA | Window | G EWALL SEA | Window5 Detailed Fenestration | NONRESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 23 | G NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 24 | iz-G EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 25 | G GFLOOR SEA | Floor | CTF - ConductionTransferFunction | GGFLOORSEA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 26 | G CEILIN SEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 27 | G INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 28 | G NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 1.154 | 0.984 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 29 | GWINDOW1 N NEA | Window | G NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 30 | G EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 1.154 | 0.984 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 31 | GWINDOW1 E NEA | Window | G EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 32 | G SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 33 | iz-G EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 34 | G GFLOOR NEA | Floor | CTF - ConductionTransferFunction | GGFLOORNEA_FFACTOR | 0.287 | 0.268 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 35 | G CEILIN NEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 36 | G INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 37 | G NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 1.154 | 0.984 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 38 | GWINDOW1 N N1A | Window | G NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 39 | G SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 40 | G EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 41 | iz-G EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 42 | G GFLOOR N1A | Floor | CTF - ConductionTransferFunction | GGFLOORN1A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 43 | G CEILIN N1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 44 | G INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 45 | G NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 1.154 | 0.984 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 46 | GWINDOW1 N N2A | Window | G NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 47 | G SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 48 | G EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 49 | iz-G EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 50 | G GFLOOR N2A | Floor | CTF - ConductionTransferFunction | GGFLOORN2A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 51 | G CEILIN N2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 52 | G INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 53 | G SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 1.154 | 0.984 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 54 | GWINDOW1 S S1A | Window | G SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 55 | G NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 56 | G EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 57 | iz-G EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 58 | G GFLOOR S1A | Floor | CTF - ConductionTransferFunction | GGFLOORS1A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 59 | G CEILIN S1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 60 | G INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 61 | G SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_GRD | 1.154 | 0.984 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 62 | GWINDOW1 S S2A | Window | G SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 63 | G NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-G NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 64 | G EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-G EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 65 | iz-G EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | G EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 66 | G GFLOOR S2A | Floor | CTF - ConductionTransferFunction | GGFLOORS2A_FFACTOR | 0.170 | 0.163 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 67 | G CEILIN S2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | G CEILIN S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 68 | G INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | G INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 69 | M WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 70 | MWINDOW1 W SWA | Window | M WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 71 | M SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 72 | MWINDOW1 S SWA | Window | M SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 73 | M NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 74 | M EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 3.05 | 7.62 | 0.00 | iz-M EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 75 | M GFLOOR SWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 76 | M CEILIN SWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 77 | M INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 78 | M NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 79 | MWINDOW1 N NWA | Window | M NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 80 | M WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 81 | MWINDOW1 W NWA | Window | M WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 82 | M SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 83 | M EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 84 | M GFLOOR NWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 85 | M CEILIN NWA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 86 | M INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 87 | M EWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 88 | MWINDOW1 E SEA | Window | M EWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 89 | M SWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 90 | MWINDOW1 S SEA | Window | M SWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 91 | M NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 92 | iz-M EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 93 | M GFLOOR SEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 94 | M CEILIN SEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 95 | M INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 96 | M NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 97 | MWINDOW1 N NEA | Window | M NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 98 | M EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 99 | MWINDOW1 E NEA | Window | M EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 100 | M SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 101 | iz-M EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 102 | M GFLOOR NEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 103 | M CEILIN NEA | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 104 | M INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 105 | M NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 106 | MWINDOW1 N N1A | Window | M NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 107 | M SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 108 | M EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 109 | iz-M EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 110 | M GFLOOR N1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 111 | M CEILIN N1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 112 | M INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 113 | M NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 114 | MWINDOW1 N N2A | Window | M NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 115 | M SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 116 | M EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 117 | iz-M EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 118 | M GFLOOR N2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 119 | M CEILIN N2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 120 | M INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 121 | M SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 122 | MWINDOW1 S S1A | Window | M SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 123 | M NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 124 | M EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 125 | iz-M EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 3.05 | 7.62 | 0.00 | M EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 126 | M GFLOOR S1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 127 | M CEILIN S1A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 128 | M INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 129 | M SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.171 | 0.996 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 130 | MWINDOW1 S S2A | Window | M SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 131 | M NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-M NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 132 | M EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-M EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 133 | iz-M EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | M EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 134 | M GFLOOR S2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | M GFLOOR S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 135 | M CEILIN S2A | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | M CEILIN S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 136 | M INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 176.50 | 176.50 | 176.50 | 0.00 | 90.00 | 176.50 | 1.00 | 0.00 | M INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 137 | T WWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 138 | TWINDOW1 W SWA | Window | T WWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 139 | T SWALL SWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 140 | TWINDOW1 S SWA | Window | T SWALL SWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 141 | T NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 142 | T EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 143 | T GFLOOR SWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 144 | T ROOF SWA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 145 | T INTERNALMASS SWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 146 | T NWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 147 | TWINDOW1 N NWA | Window | T NWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 148 | T WWALL NWA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 18.58 | 23.22 | 18.58 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 149 | TWINDOW1 W NWA | Window | T WWALL NWA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 270.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 150 | T SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 151 | T EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 152 | T GFLOOR NWA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 153 | T ROOF NWA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 154 | T INTERNALMASS NWA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 155 | T EWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 156 | TWINDOW1 E SEA | Window | T EWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 157 | T SWALL SEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 158 | TWINDOW1 S SEA | Window | T SWALL SEA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 159 | T NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 160 | iz-T EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 161 | T GFLOOR SEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 162 | T ROOF SEA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 163 | T INTERNALMASS SEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 164 | T NWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 165 | TWINDOW1 N NEA | Window | T NWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 166 | T EWALL NEA | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 18.58 | 23.22 | 18.58 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 167 | TWINDOW1 E NEA | Window | T EWALL NEA | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 4.65 | 4.65 | 4.65 | 90.00 | 90.00 | 3.81 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 168 | T SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 169 | iz-T EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 170 | T GFLOOR NEA | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 171 | T ROOF NEA | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 172 | T INTERNALMASS NEA | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 173 | T NWALL N1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 174 | TWINDOW1 N N1A | Window | T NWALL N1A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 175 | T SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 176 | T EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 177 | iz-T EIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 178 | T GFLOOR N1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 179 | T ROOF N1A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 180 | T INTERNALMASS N1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 181 | T NWALL N2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 28.24 | 35.30 | 28.24 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 182 | TWINDOW1 N N2A | Window | T NWALL N2A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 0.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 183 | T SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 184 | T EIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 185 | iz-T EIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 186 | T GFLOOR N2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 187 | T ROOF N2A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 188 | T INTERNALMASS N2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 189 | T SWALL S1A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 190 | TWINDOW1 S S1A | Window | T SWALL S1A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 191 | T NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 192 | T EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 193 | iz-T EIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 194 | T GFLOOR S1A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 195 | T ROOF S1A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 196 | T INTERNALMASS S1A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 197 | T SWALL S2A | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.430 | 1.178 | 28.24 | 35.30 | 28.24 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 198 | TWINDOW1 S S2A | Window | T SWALL S2A | Window5 Detailed Fenestration | RESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 7.06 | 7.06 | 7.06 | 180.00 | 90.00 | 5.79 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 199 | T NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | iz-T NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 200 | T EIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 90.00 | 90.00 | 7.62 | 3.05 | 0.00 | iz-T EIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 201 | iz-T EIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 23.22 | 23.22 | 23.22 | 270.00 | 90.00 | 7.62 | 3.05 | 0.00 | T EIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 202 | T GFLOOR S2A | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 88.25 | 88.25 | 88.25 | 90.00 | 180.00 | 7.62 | 11.58 | 0.00 | T GFLOOR S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 203 | T ROOF S2A | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.228 | 0.219 | 88.25 | 88.25 | 88.25 | 180.00 | 0.00 | 11.58 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 204 | T INTERNALMASS S2A | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 88.25 | 88.25 | 88.25 | 0.00 | 90.00 | 88.25 | 1.00 | 0.00 | T INTERNALMASS S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 205 | T WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.430 | 1.178 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 206 | T EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.430 | 1.178 | 3.99 | 5.11 | 3.99 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 207 | TWINDOW14 | Window | T EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 1.11 | 1.11 | 1.11 | 90.00 | 90.00 | 0.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 208 | iz-T NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 209 | iz-T NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 210 | iz-T NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 211 | iz-T NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | T NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 212 | iz-T SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 213 | iz-T SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 214 | iz-T SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 215 | iz-T SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | T SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 216 | T FLOOR C | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | T FLOOR C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 217 | T ROOF C | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 218 | G WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.154 | 0.984 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 219 | G EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.154 | 0.984 | 1.79 | 5.11 | 1.79 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 220 | ENTRANCE DOOR | Window | G EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 3.32 | 3.32 | 3.32 | 90.00 | 90.00 | 1.57 | 2.11 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 221 | iz-G NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 222 | iz-G NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 223 | iz-G NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 224 | iz-G NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | G NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 225 | iz-G SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 226 | iz-G SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 227 | iz-G SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 228 | iz-G SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | G SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 229 | G FLOOR C | Floor | CTF - ConductionTransferFunction | GFLOORC_FFACTOR | 5.502E-002 | 5.429E-002 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 230 | G CEILING C | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | G CEILING C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 231 | M WWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.171 | 0.996 | 5.11 | 5.11 | 5.11 | 270.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 232 | M EWALL C | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.171 | 0.996 | 3.99 | 5.11 | 3.99 | 90.00 | 90.00 | 1.68 | 3.05 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 233 | MWINDOW14 | Window | M EWALL C | Window5 Detailed Fenestration | NONRESWINDOW_U_0.53_SHGC_0.225 | N/A | 3.013 | No | 1.11 | 1.11 | 1.11 | 90.00 | 90.00 | 0.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
| 234 | iz-M NIWALL SWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL SWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 235 | iz-M NIWALL S1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL S1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 236 | iz-M NIWALL S2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL S2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 237 | iz-M NIWALL SEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 180.00 | 90.00 | 11.58 | 3.05 | 0.00 | M NIWALL SEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 238 | iz-M SIWALL NWA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL NWA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 239 | iz-M SIWALL N1A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL N1A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 240 | iz-M SIWALL N2A | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL N2A | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 241 | iz-M SIWALL NEA | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 35.30 | 35.30 | 35.30 | 0.00 | 90.00 | 11.58 | 3.05 | 0.00 | M SIWALL NEA | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 242 | M FLOOR C | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 77.66 | 77.66 | 77.66 | 90.00 | 180.00 | 1.68 | 46.33 | 0.00 | M FLOOR C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 243 | M CEILING C | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 77.66 | 77.66 | 77.66 | 180.00 | 0.00 | 46.33 | 1.68 | 0.00 | M CEILING C | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
| Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
| 1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | Yes | Yes | Yes | Clark and Allen |
| Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
| 1 | NEW YEAR'S DAY | Holiday | InputFile | 01/02 | 1Environment:Special Days |
| Daylight Saving Indicator | Source | Start Date | End Date | |
| 1 | Yes | InputFile | 03/12 | 11/05 |
| Style | Unit Conversion | |
| 1 | Commaandhtml | commaandhtml |
| Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
| 1 | G SW APARTMENT | RunPeriod: RUNPERIOD 1 | 3.7188395451E-002 | 5.0135752452E-002 | Pass | Pass | 3.8165134471E-002 | 0.1395091992 | Pass | Pass |
| 2 | G NW APARTMENT | RunPeriod: RUNPERIOD 1 | 2.6421928392E-002 | 2.6660199776E-002 | Pass | Pass | 3.5485778975E-002 | 5.2567906927E-002 | Pass | Pass |
| 3 | OFFICE | RunPeriod: RUNPERIOD 1 | 3.5861675453E-002 | 2.5035889470E-002 | Pass | Pass | 0.1373286400 | 0.3940135344 | Pass | Pass |
| 4 | G NE APARTMENT | RunPeriod: RUNPERIOD 1 | 2.6029111443E-002 | 2.7522459590E-002 | Pass | Pass | 3.0468484414E-002 | 4.2850424897E-002 | Pass | Pass |
| 5 | G N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.4542893209E-002 | 3.1879666133E-002 | Pass | Pass | 1.7893777621E-002 | 2.2539847230E-002 | Pass | Pass |
| 6 | G N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.4587653308E-002 | 3.1919223492E-002 | Pass | Pass | 1.7886605697E-002 | 2.2539389919E-002 | Pass | Pass |
| 7 | G S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.7828651006E-002 | 8.9852181985E-002 | Pass | Pass | 6.5436267280E-002 | 0.3983888541 | Pass | Pass |
| 8 | G S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.7711206559E-002 | 7.8017265470E-002 | Pass | Pass | 6.0653267130E-002 | 0.3830974641 | Pass | Pass |
| 9 | M SW APARTMENT | RunPeriod: RUNPERIOD 1 | 3.6758569931E-002 | 7.3006979147E-002 | Pass | Pass | 5.6824326239E-002 | 0.2869075291 | Pass | Pass |
| 10 | M NW APARTMENT | RunPeriod: RUNPERIOD 1 | 2.7499505294E-002 | 2.4159757574E-002 | Pass | Pass | 2.0184878523E-002 | 2.5406696914E-002 | Pass | Pass |
| 11 | M SE APARTMENT | RunPeriod: RUNPERIOD 1 | 3.4933002982E-002 | 6.2267888727E-002 | Pass | Pass | 5.9483077657E-002 | 0.3492915940 | Pass | Pass |
| 12 | M NE APARTMENT | RunPeriod: RUNPERIOD 1 | 2.6844183144E-002 | 2.5202784843E-002 | Pass | Pass | 2.7918831203E-002 | 4.0791961290E-002 | Pass | Pass |
| 13 | M N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.3868553040E-002 | 3.0883552033E-002 | Pass | Pass | 1.6992570991E-002 | 2.1261850503E-002 | Pass | Pass |
| 14 | M N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.3931914214E-002 | 3.0905196878E-002 | Pass | Pass | 1.6978398934E-002 | 2.1258344040E-002 | Pass | Pass |
| 15 | M S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.8976300337E-002 | 0.1146254269 | Pass | Pass | 8.6865997626E-002 | 0.4570706846 | Pass | Pass |
| 16 | M S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.9009425005E-002 | 0.1146709054 | Pass | Pass | 8.7267805051E-002 | 0.4596318323 | Pass | Pass |
| 17 | T SW APARTMENT | RunPeriod: RUNPERIOD 1 | 5.1595775351E-002 | 6.7410483125E-002 | Pass | Pass | 0.1353194978 | 0.5207580123 | Pass | Pass |
| 18 | T NW APARTMENT | RunPeriod: RUNPERIOD 1 | 2.0957466231E-002 | 3.3404165912E-002 | Pass | Pass | 0.5446340797 | 3.7261102628 | Pass | Pass |
| 19 | T SE APARTMENT | RunPeriod: RUNPERIOD 1 | 5.0098175293E-002 | 5.4527440199E-002 | Pass | Pass | 0.1719940325 | 0.9644401752 | Pass | Pass |
| 20 | T NE APARTMENT | RunPeriod: RUNPERIOD 1 | 1.8290326844E-002 | 2.9987260047E-002 | Pass | Pass | 0.2192414554 | 1.2979565031 | Pass | Pass |
| 21 | T N1 APARTMENT | RunPeriod: RUNPERIOD 1 | 1.9871081233E-002 | 2.9713811957E-002 | Pass | Pass | 0.3289761390 | 2.0247768498 | Pass | Pass |
| 22 | T N2 APARTMENT | RunPeriod: RUNPERIOD 1 | 2.0002028762E-002 | 2.9617116572E-002 | Pass | Pass | 0.3959592880 | 2.5364777908 | Pass | Pass |
| 23 | T S1 APARTMENT | RunPeriod: RUNPERIOD 1 | 5.3609698190E-002 | 6.2383175330E-002 | Pass | Pass | 0.7818209704 | 7.8340653201 | Pass | Pass |
| 24 | T S2 APARTMENT | RunPeriod: RUNPERIOD 1 | 5.3568659742E-002 | 6.2503844641E-002 | Pass | Pass | 0.3226223739 | 2.1920700974 | Pass | Pass |
| 25 | T CORRIDOR | RunPeriod: RUNPERIOD 1 | 3.1304912832E-002 | 1.9242582228E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 26 | G CORRIDOR | RunPeriod: RUNPERIOD 1 | 0.1629948901 | 0.4951306665 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 27 | M CORRIDOR | RunPeriod: RUNPERIOD 1 | 9.0846675900E-003 | 4.7683151308E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Heat Emission by Components| Envelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
| Heat Emissions [GJ] | 1208.16 | 10.79 | 0.00 | -2.9 | 1576.21 | 2792.23 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
SizingPeriod:DesignDay| Maximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
| NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 6.30 | 0.00 | 6.30 | Wetbulb [C] | 0.50 | 270.00 |
| NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 42.00 | 9.70 | 22.20 | Wetbulb [C] | 3.20 | 320.00 |
| Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
| Jan | 0.60 | 4 | |||
| Feb | 21.40 | 43 | |||
| Mar | 12.00 | 35 | |||
| Apr | 29.10 | 12 | |||
| May | 29.10 | 57 | |||
| Jun | 197.10 | 59 | |||
| Jul | 47.90 | 83 | |||
| Aug | 0.00 | 0 | |||
| Sep | 171.60 | 106 | |||
| Oct | 4.80 | 31 | |||
| Nov | 1.20 | 7 | |||
| Dec | 33.00 | 13 |
| Value | |
| None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Opaque Exterior| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| G SWALL SWA | RES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G WWALL SWA | RES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| G GFLOOR SWA | GGFLOORSWA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL NWA | RES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G WWALL NWA | RES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| G GFLOOR NWA | GGFLOORNWA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL SEA | NONRES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G EWALL SEA | NONRES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| G GFLOOR SEA | GGFLOORSEA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL NEA | RES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G EWALL NEA | RES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| G GFLOOR NEA | GGFLOORNEA_FFACTOR | 1.00 | 0.274 | 0.287 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL N1A | RES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G GFLOOR N1A | GGFLOORN1A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G NWALL N2A | RES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| G GFLOOR N2A | GGFLOORN2A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL S1A | RES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G GFLOOR S1A | GGFLOORS1A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| G SWALL S2A | RES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| G GFLOOR S2A | GGFLOORS2A_FFACTOR | 1.00 | 0.166 | 0.170 | 88.25 | 88.25 | 90.00 | 180.00 | |
| M WWALL SWA | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 46.45 | 37.16 | 270.00 | 90.00 | W |
| M SWALL SWA | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M NWALL NWA | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M WWALL NWA | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 46.45 | 37.16 | 270.00 | 90.00 | W |
| M EWALL SEA | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 46.45 | 37.16 | 90.00 | 90.00 | E |
| M SWALL SEA | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M NWALL NEA | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M EWALL NEA | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 46.45 | 37.16 | 90.00 | 90.00 | E |
| M NWALL N1A | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M NWALL N2A | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 70.60 | 56.48 | 0.00 | 90.00 | N |
| M SWALL S1A | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| M SWALL S2A | RES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 70.60 | 56.48 | 180.00 | 90.00 | S |
| T WWALL SWA | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| T SWALL SWA | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF SWA | RES_ROOF | 0.55 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL NWA | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T WWALL NWA | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 23.22 | 18.58 | 270.00 | 90.00 | W |
| T ROOF NWA | RES_ROOF | 0.55 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T EWALL SEA | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| T SWALL SEA | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF SEA | RES_ROOF | 0.55 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL NEA | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T EWALL NEA | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 23.22 | 18.58 | 90.00 | 90.00 | E |
| T ROOF NEA | RES_ROOF | 0.55 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL N1A | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T ROOF N1A | RES_ROOF | 0.55 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T NWALL N2A | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 35.30 | 28.24 | 0.00 | 90.00 | N |
| T ROOF N2A | RES_ROOF | 0.55 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T SWALL S1A | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF S1A | RES_ROOF | 0.55 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T SWALL S2A | RES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 35.30 | 28.24 | 180.00 | 90.00 | S |
| T ROOF S2A | RES_ROOF | 0.55 | 0.221 | 0.228 | 88.25 | 88.25 | 180.00 | 0.00 | |
| T WWALL C | NONRES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 5.11 | 5.11 | 270.00 | 90.00 | W |
| T EWALL C | NONRES_EXT_WALL_TOP | 0.30 | 1.178 | 1.430 | 5.11 | 3.99 | 90.00 | 90.00 | E |
| T ROOF C | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 77.66 | 77.66 | 180.00 | 0.00 | |
| G WWALL C | NONRES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 5.11 | 5.11 | 270.00 | 90.00 | W |
| G EWALL C | NONRES_EXT_WALL_GRD | 0.30 | 0.984 | 1.154 | 5.11 | 1.79 | 90.00 | 90.00 | E |
| G FLOOR C | GFLOORC_FFACTOR | 1.00 | 0.055 | 0.055 | 77.66 | 77.66 | 90.00 | 180.00 | |
| M WWALL C | NONRES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 10.22 | 10.22 | 270.00 | 90.00 | W |
| M EWALL C | NONRES_EXT_WALL_MID | 0.30 | 0.996 | 1.171 | 10.22 | 7.99 | 90.00 | 90.00 | E |
| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| G NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| G CEILIN SWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| G CEILIN NWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN SEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN NEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN N1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| G EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN N2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN S1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| G NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-G EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| G CEILIN S2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 88.25 | 88.25 | 180.00 | 0.00 | |
| M NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| M GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN SWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| M GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN NWA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN SEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN NEA | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN N1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| M EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN N2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN S1A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| M NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 90.00 | 90.00 | E |
| iz-M EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 46.45 | 46.45 | 270.00 | 90.00 | W |
| M GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 176.50 | 176.50 | 90.00 | 180.00 | |
| M CEILIN S2A | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 176.50 | 176.50 | 180.00 | 0.00 | |
| T NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| T GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| T GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| T EIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| T NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T EIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 90.00 | 90.00 | E |
| iz-T EIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 23.22 | 23.22 | 270.00 | 90.00 | W |
| T GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 88.25 | 88.25 | 90.00 | 180.00 | |
| iz-T NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-T SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-T SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| T FLOOR C | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 77.66 | 77.66 | 90.00 | 180.00 | |
| iz-G NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 180.00 | 90.00 | S |
| iz-G SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| iz-G SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 35.30 | 35.30 | 0.00 | 90.00 | N |
| G CEILING C | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 77.66 | 77.66 | 180.00 | 0.00 | |
| iz-M NIWALL SWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL S1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL S2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M NIWALL SEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 180.00 | 90.00 | S |
| iz-M SIWALL NWA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL N1A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL N2A | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| iz-M SIWALL NEA | INT_WALL | 0.30 | 2.511 | 6.299 | 70.60 | 70.60 | 0.00 | 90.00 | N |
| M FLOOR C | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 155.32 | 155.32 | 90.00 | 180.00 | |
| M CEILING C | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 155.32 | 155.32 | 180.00 | 0.00 | |
| G INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| G INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| M INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| M INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 353.00 | 0.00 | 90.00 | N | ||
| T INTERNALMASS SWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS NWA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS SEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS NEA | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS N1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS N2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS S1A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N | ||
| T INTERNALMASS S2A | INTERIORFURNISHINGS | 0.30 | 0.800 | 88.25 | 0.00 | 90.00 | N |
| Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| GWINDOW1 S SWA | RESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.226 | 0.248 | No | G SWALL SWA | 180.00 | 90.00 | S | |||||||
| GWINDOW1 W SWA | RESWINDOW_U_0.53_SHGC_0.225 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.013 | 0.226 | 0.248 | No | G WWALL SWA | 270.00 | 90.00 | W | |||||||
| GWINDOW1 N NWA | RESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.226 | 0.248 | No | G NWALL NWA | 0.00 | 90.00 | N | |||||||
| GWINDOW1 W NWA | RESWINDOW_U_0.53_SHGC_0.225 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.013 | 0.226 | 0.248 | No | G WWALL NWA | 270.00 | 90.00 | W | |||||||
| GWINDOW1 S SEA | NONRESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.226 | 0.248 | No | G SWALL SEA | 180.00 | 90.00 | S | |||||||
| GWINDOW1 E SEA | NONRESWINDOW_U_0.53_SHGC_0.225 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.013 | 0.226 | 0.248 | No | G EWALL SEA | 90.00 | 90.00 | E | |||||||
| GWINDOW1 N NEA | RESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.226 | 0.248 | No | G NWALL NEA | 0.00 | 90.00 | N | |||||||
| GWINDOW1 E NEA | RESWINDOW_U_0.53_SHGC_0.225 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.013 | 0.226 | 0.248 | No | G EWALL NEA | 90.00 | 90.00 | E | |||||||
| GWINDOW1 N N1A | RESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.226 | 0.248 | No | G NWALL N1A | 0.00 | 90.00 | N | |||||||
| GWINDOW1 N N2A | RESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.226 | 0.248 | No | G NWALL N2A | 0.00 | 90.00 | N | |||||||
| GWINDOW1 S S1A | RESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.226 | 0.248 | No | G SWALL S1A | 180.00 | 90.00 | S | |||||||
| GWINDOW1 S S2A | RESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.226 | 0.248 | No | G SWALL S2A | 180.00 | 90.00 | S | |||||||
| MWINDOW1 W SWA | RESWINDOW_U_0.53_SHGC_0.225 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 3.013 | 0.226 | 0.248 | No | M WWALL SWA | 270.00 | 90.00 | W | |||||||
| MWINDOW1 S SWA | RESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.013 | 0.226 | 0.248 | No | M SWALL SWA | 180.00 | 90.00 | S | |||||||
| MWINDOW1 N NWA | RESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.013 | 0.226 | 0.248 | No | M NWALL NWA | 0.00 | 90.00 | N | |||||||
| MWINDOW1 W NWA | RESWINDOW_U_0.53_SHGC_0.225 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 3.013 | 0.226 | 0.248 | No | M WWALL NWA | 270.00 | 90.00 | W | |||||||
| MWINDOW1 E SEA | RESWINDOW_U_0.53_SHGC_0.225 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 3.013 | 0.226 | 0.248 | No | M EWALL SEA | 90.00 | 90.00 | E | |||||||
| MWINDOW1 S SEA | RESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.013 | 0.226 | 0.248 | No | M SWALL SEA | 180.00 | 90.00 | S | |||||||
| MWINDOW1 N NEA | RESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.013 | 0.226 | 0.248 | No | M NWALL NEA | 0.00 | 90.00 | N | |||||||
| MWINDOW1 E NEA | RESWINDOW_U_0.53_SHGC_0.225 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 3.013 | 0.226 | 0.248 | No | M EWALL NEA | 90.00 | 90.00 | E | |||||||
| MWINDOW1 N N1A | RESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.013 | 0.226 | 0.248 | No | M NWALL N1A | 0.00 | 90.00 | N | |||||||
| MWINDOW1 N N2A | RESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.013 | 0.226 | 0.248 | No | M NWALL N2A | 0.00 | 90.00 | N | |||||||
| MWINDOW1 S S1A | RESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.013 | 0.226 | 0.248 | No | M SWALL S1A | 180.00 | 90.00 | S | |||||||
| MWINDOW1 S S2A | RESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 3.013 | 0.226 | 0.248 | No | M SWALL S2A | 180.00 | 90.00 | S | |||||||
| TWINDOW1 W SWA | RESWINDOW_U_0.53_SHGC_0.225 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.013 | 0.226 | 0.248 | No | T WWALL SWA | 270.00 | 90.00 | W | |||||||
| TWINDOW1 S SWA | RESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.226 | 0.248 | No | T SWALL SWA | 180.00 | 90.00 | S | |||||||
| TWINDOW1 N NWA | RESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.226 | 0.248 | No | T NWALL NWA | 0.00 | 90.00 | N | |||||||
| TWINDOW1 W NWA | RESWINDOW_U_0.53_SHGC_0.225 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.013 | 0.226 | 0.248 | No | T WWALL NWA | 270.00 | 90.00 | W | |||||||
| TWINDOW1 E SEA | RESWINDOW_U_0.53_SHGC_0.225 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.013 | 0.226 | 0.248 | No | T EWALL SEA | 90.00 | 90.00 | E | |||||||
| TWINDOW1 S SEA | RESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.226 | 0.248 | No | T SWALL SEA | 180.00 | 90.00 | S | |||||||
| TWINDOW1 N NEA | RESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.226 | 0.248 | No | T NWALL NEA | 0.00 | 90.00 | N | |||||||
| TWINDOW1 E NEA | RESWINDOW_U_0.53_SHGC_0.225 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 3.013 | 0.226 | 0.248 | No | T EWALL NEA | 90.00 | 90.00 | E | |||||||
| TWINDOW1 N N1A | RESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.226 | 0.248 | No | T NWALL N1A | 0.00 | 90.00 | N | |||||||
| TWINDOW1 N N2A | RESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.226 | 0.248 | No | T NWALL N2A | 0.00 | 90.00 | N | |||||||
| TWINDOW1 S S1A | RESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.226 | 0.248 | No | T SWALL S1A | 180.00 | 90.00 | S | |||||||
| TWINDOW1 S S2A | RESWINDOW_U_0.53_SHGC_0.225 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 3.013 | 0.226 | 0.248 | No | T SWALL S2A | 180.00 | 90.00 | S | |||||||
| TWINDOW14 | NONRESWINDOW_U_0.53_SHGC_0.225 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 3.013 | 0.226 | 0.248 | No | T EWALL C | 90.00 | 90.00 | E | |||||||
| ENTRANCE DOOR | NONRESWINDOW_U_0.53_SHGC_0.225 | 3.32 | 0.00 | 0.00 | 3.32 | 3.32 | 3.013 | 0.226 | 0.248 | No | G EWALL C | 90.00 | 90.00 | E | |||||||
| MWINDOW14 | NONRESWINDOW_U_0.53_SHGC_0.225 | 1.11 | 0.00 | 0.00 | 1.11 | 2.23 | 3.013 | 0.226 | 0.248 | No | M EWALL C | 90.00 | 90.00 | E | |||||||
| Total or Average | 306.92 | 3.013 | 0.226 | 0.248 | |||||||||||||||||
| North Total or Average | 112.97 | 3.013 | 0.226 | 0.248 | |||||||||||||||||
| Non-North Total or Average | 193.95 | 3.013 | 0.226 | 0.248 |
| Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
| None |
| Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
| Total or Average | 0.00 | - | - | - |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Sunlit Fraction| March 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
| GWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| GWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| GWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| GWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| GWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| GWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| GWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| MWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| MWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| MWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| MWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| TWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| TWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| TWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| TWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| TWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| Name | Type | Shaded Construction | Control | Glare Control | |
| None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Interior Lighting| Zone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
| LIGHTING_HARDWIRED_GSW | G SW APARTMENT | G SW APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_GNW | G NW APARTMENT | G NW APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_OFFICE | OFFICE | OFFICE | GENERAL | 7.4895 | 88.25 | 660.94 | LightsWired | LTG_SCH_OFFICE | 46.69 | 168.00 | 45.77 | 0.0000 | Y | 5.68 |
| LIGHTING_HARDWIRED_GNE | G NE APARTMENT | G NE APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_GN1 | G N1 APARTMENT | G N1 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_GN2 | G N2 APARTMENT | G N2 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_GS1 | G S1 APARTMENT | G S1 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_GS2 | G S2 APARTMENT | G S2 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_MSW | M SW APARTMENT | M SW APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_MNW | M NW APARTMENT | M NW APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_MSE | M SE APARTMENT | M SE APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_MNE | M NE APARTMENT | M NE APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_MN1 | M N1 APARTMENT | M N1 APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_MN2 | M N2 APARTMENT | M N2 APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_MS1 | M S1 APARTMENT | M S1 APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_MS2 | M S2 APARTMENT | M S2 APARTMENT | GENERAL | 4.5208 | 176.50 | 797.92 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.51 |
| LIGHTING_HARDWIRED_TSW | T SW APARTMENT | T SW APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_TNW | T NW APARTMENT | T NW APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_TSE | T SE APARTMENT | T SE APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_TNE | T NE APARTMENT | T NE APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_TN1 | T N1 APARTMENT | T N1 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_TN2 | T N2 APARTMENT | T N2 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_TS1 | T S1 APARTMENT | T S1 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_TS2 | T S2 APARTMENT | T S2 APARTMENT | GENERAL | 4.5208 | 88.25 | 398.96 | LightsWired | LTG_SCH_APARTMENT_HARDWIRED | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.76 |
| LIGHTING_HARDWIRED_GC | G CORRIDOR | G CORRIDOR | GENERAL | 5.2871 | 77.66 | 410.59 | LightsWired | LTG_SCH_CORRIDOR | 126.00 | 168.00 | 126.00 | 0.0000 | N | 9.71 |
| LIGHTING_HARDWIRED_MC | M CORRIDOR | M CORRIDOR | GENERAL | 5.2871 | 155.32 | 821.19 | LightsWired | LTG_SCH_CORRIDOR | 126.00 | 168.00 | 126.00 | 0.0000 | N | 19.42 |
| LIGHTING_HARDWIRED_TC | T CORRIDOR | T CORRIDOR | GENERAL | 5.2871 | 77.66 | 410.59 | LightsWired | LTG_SCH_CORRIDOR | 126.00 | 168.00 | 126.00 | 0.0000 | N | 9.71 |
| LIGHTING_PLUGIN_GSW | G SW APARTMENT | G SW APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_GNW | G NW APARTMENT | G NW APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_GNE | G NE APARTMENT | G NE APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_GN1 | G N1 APARTMENT | G N1 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_GN2 | G N2 APARTMENT | G N2 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_GS1 | G S1 APARTMENT | G S1 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_GS2 | G S2 APARTMENT | G S2 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_MSW | M SW APARTMENT | M SW APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_MNW | M NW APARTMENT | M NW APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_MSE | M SE APARTMENT | M SE APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_MNE | M NE APARTMENT | M NE APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_MN1 | M N1 APARTMENT | M N1 APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_MN2 | M N2 APARTMENT | M N2 APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_MS1 | M S1 APARTMENT | M S1 APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_MS2 | M S2 APARTMENT | M S2 APARTMENT | GENERAL | 0.9688 | 176.50 | 170.98 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.32 |
| LIGHTING_PLUGIN_TSW | T SW APARTMENT | T SW APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_TNW | T NW APARTMENT | T NW APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_TSE | T SE APARTMENT | T SE APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_TNE | T NE APARTMENT | T NE APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_TN1 | T N1 APARTMENT | T N1 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_TN2 | T N2 APARTMENT | T N2 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_TS1 | T S1 APARTMENT | T S1 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| LIGHTING_PLUGIN_TS2 | T S2 APARTMENT | T S2 APARTMENT | GENERAL | 0.9688 | 88.25 | 85.49 | LightsPlugIn | LTG_SCH_APARTMENT_PLUGIN | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.16 |
| Interior Lighting Total | 2.9507 | 5870.34 | 17321.34 | 55.94 |
| Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
| None |
| Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
| FACADE LIGHTING | 2101.03 | AstronomicalClock | - | 83.75 | 83.75 | 33.03 | |
| Exterior Lighting Total | 2101.03 | 33.03 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Central Plant| Type | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
| None |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
| SPLIT GSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6512.20 | 5213.92 | 1298.27 | 0.80 | 3.82 | |||
| SPLIT GNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6457.76 | 5171.50 | 1286.26 | 0.80 | 3.82 | |||
| SPLIT OFFICE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7362.06 | 5894.89 | 1467.17 | 0.80 | 3.82 | |||
| SPLIT GNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6243.28 | 4998.30 | 1244.97 | 0.80 | 3.82 | |||
| SPLIT GN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5512.09 | 4409.80 | 1102.29 | 0.80 | 3.82 | |||
| SPLIT GN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5508.35 | 4412.17 | 1096.18 | 0.80 | 3.82 | |||
| SPLIT GS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5600.84 | 4481.14 | 1119.70 | 0.80 | 3.82 | |||
| SPLIT GS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5649.04 | 4521.64 | 1127.40 | 0.80 | 3.82 | |||
| SPLIT MSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 14359.57 | 11500.83 | 2858.74 | 0.80 | 3.82 | |||
| SPLIT MNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 14260.50 | 11417.25 | 2843.25 | 0.80 | 3.82 | |||
| SPLIT MSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 13838.86 | 11076.57 | 2762.29 | 0.80 | 3.82 | |||
| SPLIT MNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 13731.44 | 10990.38 | 2741.06 | 0.80 | 3.82 | |||
| SPLIT MN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 11967.75 | 9582.67 | 2385.08 | 0.80 | 3.82 | |||
| SPLIT MN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 11959.06 | 9575.39 | 2383.67 | 0.80 | 3.82 | |||
| SPLIT MS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 12132.37 | 9710.28 | 2422.08 | 0.80 | 3.82 | |||
| SPLIT MS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 12123.76 | 9702.98 | 2420.78 | 0.80 | 3.82 | |||
| SPLIT TSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7873.36 | 6300.33 | 1573.03 | 0.80 | 3.82 | |||
| SPLIT TNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7871.05 | 6299.72 | 1571.33 | 0.80 | 3.82 | |||
| SPLIT TSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7495.58 | 6001.46 | 1494.13 | 0.80 | 3.82 | |||
| SPLIT TNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7490.69 | 5999.94 | 1490.75 | 0.80 | 3.82 | |||
| SPLIT TN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6728.08 | 5383.54 | 1344.54 | 0.80 | 3.82 | |||
| SPLIT TN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6715.58 | 5373.15 | 1342.43 | 0.80 | 3.82 | |||
| SPLIT TS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6742.38 | 5396.60 | 1345.79 | 0.80 | 3.82 | |||
| SPLIT TS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6730.02 | 5386.25 | 1343.77 | 0.80 | 3.82 |
| DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
| SPLIT GSW HP COOLING COIL | 6226.2 | 3.11 | 10.63 | 11.05 | 10.45 | 10.43 | |
| SPLIT GNW HP COOLING COIL | 6172.4 | 3.11 | 10.61 | 11.04 | 10.44 | 10.41 | |
| SPLIT OFFICE HP COOLING COIL | 7028.4 | 3.10 | 10.56 | 10.98 | 10.39 | 10.34 | |
| SPLIT GNE HP COOLING COIL | 5968.4 | 3.11 | 10.62 | 11.04 | 10.45 | 10.42 | |
| SPLIT GN1 HP COOLING COIL | 5272.6 | 3.12 | 10.65 | 11.07 | 10.47 | 10.46 | |
| SPLIT GN2 HP COOLING COIL | 5269.0 | 3.12 | 10.65 | 11.07 | 10.48 | 10.46 | |
| SPLIT GS1 HP COOLING COIL | 5360.3 | 3.13 | 10.67 | 11.10 | 10.50 | 10.49 | |
| SPLIT GS2 HP COOLING COIL | 5406.2 | 3.13 | 10.67 | 11.10 | 10.50 | 10.49 | |
| SPLIT MSW HP COOLING COIL | 13723.1 | 3.11 | 10.61 | 11.03 | 10.43 | 10.40 | |
| SPLIT MNW HP COOLING COIL | 13625.3 | 3.11 | 10.60 | 11.02 | 10.42 | 10.39 | |
| SPLIT MSE HP COOLING COIL | 13228.1 | 3.11 | 10.61 | 11.04 | 10.44 | 10.41 | |
| SPLIT MNE HP COOLING COIL | 13122.0 | 3.11 | 10.60 | 11.03 | 10.43 | 10.40 | |
| SPLIT MN1 HP COOLING COIL | 11443.7 | 3.12 | 10.63 | 11.06 | 10.46 | 10.44 | |
| SPLIT MN2 HP COOLING COIL | 11435.4 | 3.12 | 10.63 | 11.06 | 10.46 | 10.44 | |
| SPLIT MS1 HP COOLING COIL | 11606.2 | 3.12 | 10.65 | 11.08 | 10.48 | 10.47 | |
| SPLIT MS2 HP COOLING COIL | 11598.1 | 3.12 | 10.65 | 11.08 | 10.48 | 10.47 | |
| SPLIT TSW HP COOLING COIL | 7521.1 | 3.10 | 10.59 | 11.01 | 10.41 | 10.37 | |
| SPLIT TNW HP COOLING COIL | 7517.7 | 3.10 | 10.58 | 11.00 | 10.41 | 10.36 | |
| SPLIT TSE HP COOLING COIL | 7161.7 | 3.11 | 10.60 | 11.02 | 10.42 | 10.39 | |
| SPLIT TNE HP COOLING COIL | 7155.7 | 3.10 | 10.59 | 11.01 | 10.42 | 10.38 | |
| SPLIT TN1 HP COOLING COIL | 6429.6 | 3.11 | 10.60 | 11.03 | 10.43 | 10.40 | |
| SPLIT TN2 HP COOLING COIL | 6417.7 | 3.11 | 10.61 | 11.03 | 10.43 | 10.40 | |
| SPLIT TS1 HP COOLING COIL | 6444.8 | 3.11 | 10.61 | 11.04 | 10.44 | 10.41 | |
| SPLIT TS2 HP COOLING COIL | 6433.1 | 3.11 | 10.62 | 11.04 | 10.44 | 10.41 |
| DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
| SPLIT GSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT OFFICE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT GS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT MS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | ||||||||
| SPLIT TS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed |
| DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
| SPLIT GSW HEATING COIL | Coil:Heating:DX:SingleSpeed | 6802.0 | 3778.4 | 8.07 | 4 |
| SPLIT GNW HEATING COIL | Coil:Heating:DX:SingleSpeed | 6746.9 | 3748.6 | 8.07 | 4 |
| SPLIT OFFICE HEATING COIL | Coil:Heating:DX:SingleSpeed | 7700.0 | 4281.8 | 8.10 | 4 |
| SPLIT GNE HEATING COIL | Coil:Heating:DX:SingleSpeed | 6521.8 | 3623.1 | 8.15 | 4 |
| SPLIT GN1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5754.8 | 3195.6 | 8.10 | 4 |
| SPLIT GN2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5750.9 | 3193.4 | 8.10 | 4 |
| SPLIT GS1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5844.7 | 3244.2 | 8.11 | 4 |
| SPLIT GS2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5895.2 | 3272.4 | 8.12 | 4 |
| SPLIT MSW HEATING COIL | Coil:Heating:DX:SingleSpeed | 15004.5 | 8337.4 | 8.11 | 4 |
| SPLIT MNW HEATING COIL | Coil:Heating:DX:SingleSpeed | 14904.0 | 8283.0 | 8.10 | 4 |
| SPLIT MSE HEATING COIL | Coil:Heating:DX:SingleSpeed | 14457.7 | 8032.4 | 8.09 | 4 |
| SPLIT MNE HEATING COIL | Coil:Heating:DX:SingleSpeed | 14348.9 | 7973.5 | 8.09 | 4 |
| SPLIT MN1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 12498.8 | 6942.3 | 8.13 | 4 |
| SPLIT MN2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 12489.7 | 6937.2 | 8.13 | 4 |
| SPLIT MS1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 12665.6 | 7032.6 | 8.15 | 4 |
| SPLIT MS2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 12656.6 | 7027.6 | 8.15 | 4 |
| SPLIT TSW HEATING COIL | Coil:Heating:DX:SingleSpeed | 8230.3 | 4574.7 | 8.07 | 4 |
| SPLIT TNW HEATING COIL | Coil:Heating:DX:SingleSpeed | 8229.0 | 4574.5 | 8.06 | 4 |
| SPLIT TSE HEATING COIL | Coil:Heating:DX:SingleSpeed | 7833.9 | 4353.7 | 8.12 | 4 |
| SPLIT TNE HEATING COIL | Coil:Heating:DX:SingleSpeed | 7830.0 | 4352.1 | 8.12 | 4 |
| SPLIT TN1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 7030.5 | 3906.6 | 8.08 | 4 |
| SPLIT TN2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 7017.3 | 3899.3 | 8.08 | 4 |
| SPLIT TS1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 7043.9 | 3913.4 | 8.08 | 4 |
| SPLIT TS2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 7030.9 | 3906.2 | 8.08 | 4 |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
| SPLIT GSW HEATING COIL | Coil:Heating:DX:SingleSpeed | 6512.20 | 3.81 | |
| SPLIT GSW_SUPPHEATCOIL | Coil:Heating:Electric | 6512.20 | 1.00 | |
| SPLIT GNW HEATING COIL | Coil:Heating:DX:SingleSpeed | 6457.76 | 3.81 | |
| SPLIT GNW_SUPPHEATCOIL | Coil:Heating:Electric | 6457.76 | 1.00 | |
| SPLIT OFFICE HEATING COIL | Coil:Heating:DX:SingleSpeed | 7362.06 | 3.81 | |
| SPLIT OFFICE_SUPPHEATCOIL | Coil:Heating:Electric | 7362.06 | 1.00 | |
| SPLIT GNE HEATING COIL | Coil:Heating:DX:SingleSpeed | 6243.28 | 3.81 | |
| SPLIT GNE_SUPPHEATCOIL | Coil:Heating:Electric | 6243.28 | 1.00 | |
| SPLIT GN1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5512.09 | 3.81 | |
| SPLIT GN1_SUPPHEATCOIL | Coil:Heating:Electric | 5512.09 | 1.00 | |
| SPLIT GN2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5508.35 | 3.81 | |
| SPLIT GN2_SUPPHEATCOIL | Coil:Heating:Electric | 5508.35 | 1.00 | |
| SPLIT GS1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5600.84 | 3.81 | |
| SPLIT GS1_SUPPHEATCOIL | Coil:Heating:Electric | 5600.84 | 1.00 | |
| SPLIT GS2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 5649.04 | 3.81 | |
| SPLIT GS2_SUPPHEATCOIL | Coil:Heating:Electric | 5649.04 | 1.00 | |
| SPLIT MSW HEATING COIL | Coil:Heating:DX:SingleSpeed | 14359.57 | 3.81 | |
| SPLIT MSW_SUPPHEATCOIL | Coil:Heating:Electric | 14359.57 | 1.00 | |
| SPLIT MNW HEATING COIL | Coil:Heating:DX:SingleSpeed | 14260.50 | 3.81 | |
| SPLIT MNW_SUPPHEATCOIL | Coil:Heating:Electric | 14260.50 | 1.00 | |
| SPLIT MSE HEATING COIL | Coil:Heating:DX:SingleSpeed | 13838.86 | 3.81 | |
| SPLIT MSE_SUPPHEATCOIL | Coil:Heating:Electric | 13838.86 | 1.00 | |
| SPLIT MNE HEATING COIL | Coil:Heating:DX:SingleSpeed | 13731.44 | 3.81 | |
| SPLIT MNE_SUPPHEATCOIL | Coil:Heating:Electric | 13731.44 | 1.00 | |
| SPLIT MN1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 11967.75 | 3.81 | |
| SPLIT MN1_SUPPHEATCOIL | Coil:Heating:Electric | 11967.75 | 1.00 | |
| SPLIT MN2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 11959.06 | 3.81 | |
| SPLIT MN2_SUPPHEATCOIL | Coil:Heating:Electric | 11959.06 | 1.00 | |
| SPLIT MS1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 12132.37 | 3.81 | |
| SPLIT MS1_SUPPHEATCOIL | Coil:Heating:Electric | 12132.37 | 1.00 | |
| SPLIT MS2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 12123.76 | 3.81 | |
| SPLIT MS2_SUPPHEATCOIL | Coil:Heating:Electric | 12123.76 | 1.00 | |
| SPLIT TSW HEATING COIL | Coil:Heating:DX:SingleSpeed | 7873.36 | 3.81 | |
| SPLIT TSW_SUPPHEATCOIL | Coil:Heating:Electric | 7873.36 | 1.00 | |
| SPLIT TNW HEATING COIL | Coil:Heating:DX:SingleSpeed | 7871.05 | 3.81 | |
| SPLIT TNW_SUPPHEATCOIL | Coil:Heating:Electric | 7871.05 | 1.00 | |
| SPLIT TSE HEATING COIL | Coil:Heating:DX:SingleSpeed | 7495.58 | 3.81 | |
| SPLIT TSE_SUPPHEATCOIL | Coil:Heating:Electric | 7495.58 | 1.00 | |
| SPLIT TNE HEATING COIL | Coil:Heating:DX:SingleSpeed | 7490.69 | 3.81 | |
| SPLIT TNE_SUPPHEATCOIL | Coil:Heating:Electric | 7490.69 | 1.00 | |
| SPLIT TN1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 6728.08 | 3.81 | |
| SPLIT TN1_SUPPHEATCOIL | Coil:Heating:Electric | 6728.08 | 1.00 | |
| SPLIT TN2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 6715.58 | 3.81 | |
| SPLIT TN2_SUPPHEATCOIL | Coil:Heating:Electric | 6715.58 | 1.00 | |
| SPLIT TS1 HEATING COIL | Coil:Heating:DX:SingleSpeed | 6742.38 | 3.81 | |
| SPLIT TS1_SUPPHEATCOIL | Coil:Heating:Electric | 6742.38 | 1.00 | |
| SPLIT TS2 HEATING COIL | Coil:Heating:DX:SingleSpeed | 6730.02 | 3.81 | |
| SPLIT TS2_SUPPHEATCOIL | Coil:Heating:Electric | 6730.02 | 1.00 |
| Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
| G SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| G S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| M SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M SE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M SE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| M S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.05 | 46.34 | 892.76 | 1.00 | 3.85 | General | ||
| T SW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T SW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T NW APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T NW APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T SE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T SE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T NE APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T NE APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T N1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T N1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T N2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T N2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T S1 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T S1 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T S2 APARTMENT ERV SUP FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| T S2 APARTMENT ERV EXH FAN | Fan:OnOff | 0.30 | 270.65 | 0.03 | 23.17 | 892.76 | 1.00 | 6.84 | General | ||
| SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.36 | 408.27 | 1120.11 | 1.00 | 1.77 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 |
| SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.36 | 407.45 | 1120.11 | 1.00 | 1.77 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 |
| SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.43 | 476.56 | 1120.11 | 1.00 | 1.68 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 09:00:00 |
| SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.35 | 392.50 | 1120.11 | 1.00 | 1.79 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 |
| SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 341.90 | 1120.11 | 1.00 | 1.88 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 |
| SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 341.64 | 1120.11 | 1.00 | 1.88 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 |
| SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 343.35 | 1120.11 | 1.00 | 1.88 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 |
| SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 346.66 | 1120.11 | 1.00 | 1.87 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 |
| SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.81 | 908.92 | 1120.11 | 1.00 | 1.43 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 |
| SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.81 | 907.11 | 1120.11 | 1.00 | 1.43 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 |
| SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.78 | 872.08 | 1120.11 | 1.00 | 1.44 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 |
| SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.78 | 870.33 | 1120.11 | 1.00 | 1.44 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 |
| SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.67 | 748.25 | 1120.11 | 1.00 | 1.49 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 |
| SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.67 | 747.65 | 1120.11 | 1.00 | 1.49 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 |
| SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.67 | 751.07 | 1120.11 | 1.00 | 1.49 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 |
| SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.67 | 750.46 | 1120.11 | 1.00 | 1.49 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 |
| SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.45 | 503.13 | 1120.11 | 1.00 | 1.66 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 |
| SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.45 | 504.66 | 1120.11 | 1.00 | 1.65 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 |
| SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.43 | 476.86 | 1120.11 | 1.00 | 1.68 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 |
| SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.43 | 478.37 | 1120.11 | 1.00 | 1.68 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 |
| SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.38 | 426.17 | 1120.11 | 1.00 | 1.74 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 |
| SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.38 | 425.30 | 1120.11 | 1.00 | 1.75 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 |
| SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.38 | 424.89 | 1120.11 | 1.00 | 1.75 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 |
| SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.38 | 424.02 | 1120.11 | 1.00 | 1.75 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 |
| Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
| SWHSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 29891.00 | 0.000113 | 14.49 | 127739.32 | 0.30 | General |
| Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
| SWHSYS1 WATER HEATER | WaterHeater:Mixed | 0.95 | 53912.00 | 0.80 | 11.45 | 0.46 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Zone Sensible Cooling| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| G SW APARTMENT | 4188.84 | 5026.61 | 56.96 | 0.304 | 0.364 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 24.00 | 24.00 | 0.00814 | 38.22 | 0.00915 | 0.026 | 0.00 |
| G NW APARTMENT | 4180.70 | 5016.84 | 56.85 | 0.303 | 0.364 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 24.00 | 24.00 | 0.00810 | 38.22 | 0.00915 | 0.026 | 0.00 |
| OFFICE | 4816.11 | 5779.33 | 65.49 | 0.355 | 0.425 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 09:00:00 | 23.90 | 23.90 | 0.00801 | 36.66 | 0.00915 | 0.038 | 0.00 |
| G NE APARTMENT | 4031.35 | 4837.62 | 54.82 | 0.292 | 0.350 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 24.00 | 24.00 | 0.00811 | 38.22 | 0.00915 | 0.026 | 0.00 |
| G N1 APARTMENT | 3523.39 | 4228.06 | 47.91 | 0.254 | 0.305 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 24.00 | 24.00 | 0.00813 | 38.22 | 0.00915 | 0.026 | 0.00 |
| G N2 APARTMENT | 3520.77 | 4224.93 | 47.87 | 0.254 | 0.305 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 24.00 | 24.00 | 0.00813 | 38.22 | 0.00915 | 0.026 | 0.00 |
| G S1 APARTMENT | 3537.84 | 4245.41 | 48.11 | 0.255 | 0.307 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 24.00 | 24.00 | 0.00822 | 38.22 | 0.00915 | 0.026 | 0.00 |
| G S2 APARTMENT | 3570.98 | 4285.18 | 48.56 | 0.258 | 0.309 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 24.00 | 24.00 | 0.00821 | 38.22 | 0.00915 | 0.026 | 0.00 |
| M SW APARTMENT | 9303.99 | 11164.79 | 126.51 | 0.676 | 0.811 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 24.00 | 24.00 | 0.00813 | 38.22 | 0.00915 | 0.052 | 0.00 |
| M NW APARTMENT | 9286.04 | 11143.24 | 126.27 | 0.675 | 0.810 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 24.00 | 24.00 | 0.00809 | 38.22 | 0.00915 | 0.052 | 0.00 |
| M SE APARTMENT | 8934.15 | 10720.98 | 121.49 | 0.649 | 0.779 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 24.00 | 24.00 | 0.00814 | 38.22 | 0.00915 | 0.052 | 0.00 |
| M NE APARTMENT | 8916.69 | 10700.03 | 121.25 | 0.648 | 0.777 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 24.00 | 24.00 | 0.00810 | 38.22 | 0.00915 | 0.052 | 0.00 |
| M N1 APARTMENT | 7695.79 | 9234.95 | 104.65 | 0.557 | 0.668 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 24.00 | 24.00 | 0.00812 | 38.22 | 0.00915 | 0.052 | 0.00 |
| M N2 APARTMENT | 7689.77 | 9227.72 | 104.56 | 0.556 | 0.667 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 24.00 | 24.00 | 0.00812 | 38.22 | 0.00915 | 0.052 | 0.00 |
| M S1 APARTMENT | 7723.76 | 9268.51 | 105.03 | 0.559 | 0.671 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 24.00 | 24.00 | 0.00819 | 38.22 | 0.00915 | 0.052 | 0.00 |
| M S2 APARTMENT | 7717.68 | 9261.22 | 104.94 | 0.558 | 0.670 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 24.00 | 24.00 | 0.00819 | 38.22 | 0.00915 | 0.052 | 0.00 |
| T SW APARTMENT | 5144.55 | 6173.46 | 69.95 | 0.374 | 0.449 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 24.00 | 24.00 | 0.00810 | 38.22 | 0.00915 | 0.026 | 0.00 |
| T NW APARTMENT | 5159.89 | 6191.87 | 70.16 | 0.375 | 0.451 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 24.00 | 24.00 | 0.00808 | 38.22 | 0.00915 | 0.026 | 0.00 |
| T SE APARTMENT | 4880.31 | 5856.37 | 66.36 | 0.355 | 0.426 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 24.00 | 24.00 | 0.00811 | 38.22 | 0.00915 | 0.026 | 0.00 |
| T NE APARTMENT | 4895.54 | 5874.65 | 66.57 | 0.356 | 0.427 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 24.00 | 24.00 | 0.00808 | 38.22 | 0.00915 | 0.026 | 0.00 |
| T N1 APARTMENT | 4370.43 | 5244.51 | 59.43 | 0.317 | 0.380 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 24.00 | 24.00 | 0.00809 | 38.22 | 0.00915 | 0.026 | 0.00 |
| T N2 APARTMENT | 4361.75 | 5234.10 | 59.31 | 0.316 | 0.380 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 24.00 | 24.00 | 0.00809 | 38.22 | 0.00915 | 0.026 | 0.00 |
| T S1 APARTMENT | 4357.54 | 5229.05 | 59.25 | 0.316 | 0.379 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 24.00 | 24.00 | 0.00813 | 38.22 | 0.00915 | 0.026 | 0.00 |
| T S2 APARTMENT | 4348.88 | 5218.65 | 59.14 | 0.315 | 0.379 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 24.00 | 24.00 | 0.00813 | 38.22 | 0.00915 | 0.026 | 0.00 |
| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| G SW APARTMENT | 729.79 | 875.74 | 9.92 | 0.032 | 0.039 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00797 | 6.30 | 0.00607 | 0.026 | 0.00 |
| G NW APARTMENT | 608.76 | 730.52 | 8.28 | 0.027 | 0.032 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 21.10 | 21.10 | 0.00849 | 6.30 | 0.00607 | 0.026 | 0.00 |
| OFFICE | 1040.03 | 1248.04 | 14.14 | 0.046 | 0.055 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | 21.10 | 21.10 | 0.00798 | 6.30 | 0.00607 | 0.038 | 0.00 |
| G NE APARTMENT | 608.34 | 730.01 | 8.27 | 0.027 | 0.032 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 21.10 | 21.10 | 0.00849 | 6.30 | 0.00607 | 0.026 | 0.00 |
| G N1 APARTMENT | 285.71 | 342.85 | 3.89 | 0.013 | 0.026 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 21.10 | 21.10 | 0.00905 | 6.30 | 0.00607 | 0.026 | 0.00 |
| G N2 APARTMENT | 285.69 | 342.83 | 3.88 | 0.013 | 0.026 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 21.10 | 21.10 | 0.00905 | 6.30 | 0.00607 | 0.026 | 0.00 |
| G S1 APARTMENT | 406.73 | 488.08 | 5.53 | 0.018 | 0.026 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00797 | 6.30 | 0.00607 | 0.026 | 0.00 |
| G S2 APARTMENT | 414.98 | 497.97 | 5.64 | 0.018 | 0.026 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:30:00 | 21.10 | 21.10 | 0.00797 | 6.30 | 0.00607 | 0.026 | 0.00 |
| M SW APARTMENT | 1595.86 | 1915.03 | 21.70 | 0.071 | 0.085 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00797 | 6.30 | 0.00607 | 0.052 | 0.00 |
| M NW APARTMENT | 1319.54 | 1583.45 | 17.94 | 0.058 | 0.070 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00845 | 6.30 | 0.00607 | 0.052 | 0.00 |
| M SE APARTMENT | 1594.81 | 1913.77 | 21.69 | 0.070 | 0.085 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00797 | 6.30 | 0.00607 | 0.052 | 0.00 |
| M NE APARTMENT | 1318.40 | 1582.08 | 17.93 | 0.058 | 0.070 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00845 | 6.30 | 0.00607 | 0.052 | 0.00 |
| M N1 APARTMENT | 551.11 | 661.33 | 7.49 | 0.024 | 0.052 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00912 | 6.30 | 0.00607 | 0.052 | 0.00 |
| M N2 APARTMENT | 551.08 | 661.29 | 7.49 | 0.024 | 0.052 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00912 | 6.30 | 0.00607 | 0.052 | 0.00 |
| M S1 APARTMENT | 819.86 | 983.83 | 11.15 | 0.036 | 0.052 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00796 | 6.30 | 0.00607 | 0.052 | 0.00 |
| M S2 APARTMENT | 819.83 | 983.80 | 11.15 | 0.036 | 0.052 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00796 | 6.30 | 0.00607 | 0.052 | 0.00 |
| T SW APARTMENT | 1358.04 | 1629.64 | 18.47 | 0.060 | 0.072 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00797 | 6.30 | 0.00607 | 0.026 | 0.00 |
| T NW APARTMENT | 1210.35 | 1452.42 | 16.46 | 0.054 | 0.064 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00824 | 6.30 | 0.00607 | 0.026 | 0.00 |
| T SE APARTMENT | 1357.37 | 1628.85 | 18.46 | 0.060 | 0.072 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00797 | 6.30 | 0.00607 | 0.026 | 0.00 |
| T NE APARTMENT | 1209.62 | 1451.54 | 16.45 | 0.053 | 0.064 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00824 | 6.30 | 0.00607 | 0.026 | 0.00 |
| T N1 APARTMENT | 806.42 | 967.71 | 10.97 | 0.036 | 0.043 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00837 | 6.30 | 0.00607 | 0.026 | 0.00 |
| T N2 APARTMENT | 806.40 | 967.68 | 10.97 | 0.036 | 0.043 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00837 | 6.30 | 0.00607 | 0.026 | 0.00 |
| T S1 APARTMENT | 955.04 | 1146.05 | 12.99 | 0.042 | 0.051 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00798 | 6.30 | 0.00607 | 0.026 | 0.00 |
| T S2 APARTMENT | 955.02 | 1146.02 | 12.99 | 0.042 | 0.051 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 21.10 | 21.10 | 0.00798 | 6.30 | 0.00607 | 0.026 | 0.00 |
| Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
| SPLIT GSW | 0.36 | 0.36 | 0.04 | 0.04 | 0.3645 | 0.3645 | 0.3645 | 1.0000 | 1.0000 |
| SPLIT GNW | 0.36 | 0.36 | 0.03 | 0.03 | 0.3638 | 0.3638 | 0.3638 | 1.0000 | 1.0000 |
| SPLIT OFFICE | 0.43 | 0.43 | 0.06 | 0.06 | 0.4255 | 0.4255 | 0.4255 | 1.0000 | 1.0000 |
| SPLIT GNE | 0.35 | 0.35 | 0.03 | 0.03 | 0.3504 | 0.3504 | 0.3504 | 1.0000 | 1.0000 |
| SPLIT GN1 | 0.31 | 0.31 | 0.03 | 0.03 | 0.3052 | 0.3052 | 0.3052 | 1.0000 | 1.0000 |
| SPLIT GN2 | 0.31 | 0.31 | 0.03 | 0.03 | 0.3050 | 0.3050 | 0.3050 | 1.0000 | 1.0000 |
| SPLIT GS1 | 0.31 | 0.31 | 0.03 | 0.03 | 0.3065 | 0.3065 | 0.3065 | 1.0000 | 1.0000 |
| SPLIT GS2 | 0.31 | 0.31 | 0.03 | 0.03 | 0.3095 | 0.3095 | 0.3095 | 1.0000 | 1.0000 |
| SPLIT MSW | 0.81 | 0.81 | 0.08 | 0.08 | 0.8115 | 0.8115 | 0.8115 | 1.0000 | 1.0000 |
| SPLIT MNW | 0.81 | 0.81 | 0.07 | 0.07 | 0.8098 | 0.8098 | 0.8098 | 1.0000 | 1.0000 |
| SPLIT MSE | 0.78 | 0.78 | 0.08 | 0.08 | 0.7786 | 0.7786 | 0.7786 | 1.0000 | 1.0000 |
| SPLIT MNE | 0.78 | 0.78 | 0.07 | 0.07 | 0.7770 | 0.7770 | 0.7770 | 1.0000 | 1.0000 |
| SPLIT MN1 | 0.67 | 0.67 | 0.05 | 0.05 | 0.6680 | 0.6680 | 0.6680 | 1.0000 | 1.0000 |
| SPLIT MN2 | 0.67 | 0.67 | 0.05 | 0.05 | 0.6675 | 0.6675 | 0.6675 | 1.0000 | 1.0000 |
| SPLIT MS1 | 0.67 | 0.67 | 0.05 | 0.05 | 0.6705 | 0.6705 | 0.6705 | 1.0000 | 1.0000 |
| SPLIT MS2 | 0.67 | 0.67 | 0.05 | 0.05 | 0.6700 | 0.6700 | 0.6700 | 1.0000 | 1.0000 |
| SPLIT TSW | 0.45 | 0.45 | 0.07 | 0.07 | 0.4492 | 0.4492 | 0.4492 | 1.0000 | 1.0000 |
| SPLIT TNW | 0.45 | 0.45 | 0.06 | 0.06 | 0.4505 | 0.4505 | 0.4505 | 1.0000 | 1.0000 |
| SPLIT TSE | 0.43 | 0.43 | 0.07 | 0.07 | 0.4257 | 0.4257 | 0.4257 | 1.0000 | 1.0000 |
| SPLIT TNE | 0.43 | 0.43 | 0.06 | 0.06 | 0.4271 | 0.4271 | 0.4271 | 1.0000 | 1.0000 |
| SPLIT TN1 | 0.38 | 0.38 | 0.04 | 0.04 | 0.3805 | 0.3805 | 0.3805 | 1.0000 | 1.0000 |
| SPLIT TN2 | 0.38 | 0.38 | 0.04 | 0.04 | 0.3797 | 0.3797 | 0.3797 | 1.0000 | 1.0000 |
| SPLIT TS1 | 0.38 | 0.38 | 0.05 | 0.05 | 0.3793 | 0.3793 | 0.3793 | 1.0000 | 1.0000 |
| SPLIT TS2 | 0.38 | 0.38 | 0.05 | 0.05 | 0.3786 | 0.3786 | 0.3786 | 1.0000 | 1.0000 |
| Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
| None |
| Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
| SPLIT GSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GSW | 6512.197 | 5213.924 | 0.364495 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 5824.11 | 5630.14 | 0.364495 | 25.99 | 16.58 | 0.00821604 | 12.80 | 11.37 | 0.00800000 | 38.22 | 0.00915158 | 21.18 | 7.1207 | 24.00 | 0.00814431 | 42.7611 | 4188.84 | 0.00 | 6511.09 | 5140.31 |
| SPLIT GSW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT GSW | 6512.197 | 6512.197 | 0.364495 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6512.20 | 6512.20 | 0.364495 | 20.05 | 14.10 | 0.00783910 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 7.1207 | 21.10 | 0.00797456 | 49.9465 | 729.79 | 0.00 | 6520.75 | 6520.75 |
| SPLIT GSW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT GSW | 6512.197 | 6512.197 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6512.20 | 6512.20 | 0.364495 | 20.05 | 14.10 | 0.00783910 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 7.1207 | 21.10 | 0.00797456 | 49.9465 | 729.79 | 0.00 | -999.00 | -999.00 |
| SPLIT GNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GNW | 6457.757 | 5171.500 | 0.363761 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 5769.44 | 5613.52 | 0.363761 | 25.99 | 16.55 | 0.00817419 | 12.80 | 11.37 | 0.00800000 | 38.22 | 0.00915158 | 21.18 | 7.1351 | 24.00 | 0.00809909 | 42.5262 | 4180.70 | 0.00 | 6456.66 | 5098.88 |
| SPLIT GNW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT GNW | 6457.757 | 6457.757 | 0.363761 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6457.76 | 6457.76 | 0.363761 | 20.04 | 14.54 | 0.00832072 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 7.1351 | 21.10 | 0.00849347 | 53.1514 | 608.76 | 0.00 | 6466.24 | 6466.24 |
| SPLIT GNW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT GNW | 6457.757 | 6457.757 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6457.76 | 6457.76 | 0.363761 | 20.04 | 14.54 | 0.00832072 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 7.1351 | 21.10 | 0.00849347 | 53.1514 | 608.76 | 0.00 | -999.00 | -999.00 |
| SPLIT OFFICE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT OFFICE | 7362.061 | 5894.893 | 0.425456 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 09:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 09:00:00 | 6691.56 | 6574.20 | 0.425456 | 26.03 | 16.51 | 0.00811224 | 12.80 | 11.37 | 0.00800000 | 36.66 | 0.00914901 | 20.73 | 8.9565 | 23.90 | 0.00801025 | 42.3183 | 4816.11 | 0.00 | 7360.81 | 5811.00 |
| SPLIT OFFICE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT OFFICE | 7362.061 | 7362.061 | 0.425456 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | 7362.06 | 7362.06 | 0.425456 | 19.77 | 13.97 | 0.00781103 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 8.9565 | 21.10 | 0.00798207 | 49.9929 | 1040.03 | 0.00 | 7371.74 | 7371.74 |
| SPLIT OFFICE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT OFFICE | 7362.061 | 7362.061 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | 7362.06 | 7362.06 | 0.425456 | 19.77 | 13.97 | 0.00781103 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 8.9565 | 21.10 | 0.00798207 | 49.9929 | 1040.03 | 0.00 | -999.00 | -999.00 |
| SPLIT GNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GNE | 6243.278 | 4998.303 | 0.350417 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 5581.24 | 5423.16 | 0.350417 | 26.03 | 16.57 | 0.00818323 | 12.80 | 11.37 | 0.00800000 | 38.22 | 0.00915158 | 21.18 | 7.4068 | 24.00 | 0.00810577 | 42.5608 | 4031.35 | 0.00 | 6242.22 | 4927.94 |
| SPLIT GNE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT GNE | 6243.278 | 6243.278 | 0.350417 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6243.28 | 6243.28 | 0.350417 | 20.00 | 14.51 | 0.00831444 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 7.4068 | 21.10 | 0.00849379 | 53.1534 | 608.34 | 0.00 | 6251.48 | 6251.48 |
| SPLIT GNE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT GNE | 6243.278 | 6243.278 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | 6243.28 | 6243.28 | 0.350417 | 20.00 | 14.51 | 0.00831444 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 7.4068 | 21.10 | 0.00849379 | 53.1534 | 608.34 | 0.00 | -999.00 | -999.00 |
| SPLIT GN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GN1 | 5512.094 | 4409.805 | 0.305242 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 4939.01 | 4777.12 | 0.305242 | 26.17 | 16.65 | 0.00821498 | 12.80 | 11.37 | 0.00800000 | 38.22 | 0.00915158 | 21.18 | 8.5029 | 24.00 | 0.00812794 | 42.6758 | 3523.39 | 0.00 | 5511.16 | 4346.90 |
| SPLIT GN1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT GN1 | 5512.094 | 5512.094 | 0.305242 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 5512.09 | 5512.09 | 0.305242 | 19.84 | 14.89 | 0.00880075 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 8.5029 | 21.10 | 0.00901588 | 56.3742 | 236.27 | 0.00 | 5519.34 | 5519.34 |
| SPLIT GN1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT GN1 | 5512.094 | 5512.094 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 5512.09 | 5512.09 | 0.305242 | 19.84 | 14.89 | 0.00880075 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 8.5029 | 21.10 | 0.00901588 | 56.3742 | 236.27 | 0.00 | -999.00 | -999.00 |
| SPLIT GN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GN2 | 5508.348 | 4412.167 | 0.305010 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 4935.73 | 4773.80 | 0.305010 | 26.18 | 16.65 | 0.00821518 | 12.80 | 11.37 | 0.00800000 | 38.22 | 0.00915158 | 21.18 | 8.5094 | 24.00 | 0.00812809 | 42.6766 | 3520.77 | 0.00 | 5507.41 | 4349.05 |
| SPLIT GN2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT GN2 | 5508.348 | 5508.348 | 0.305010 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 5508.35 | 5508.35 | 0.305010 | 19.84 | 14.89 | 0.00880060 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 8.5094 | 21.10 | 0.00901592 | 56.3744 | 236.26 | 0.00 | 5515.59 | 5515.59 |
| SPLIT GN2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT GN2 | 5508.348 | 5508.348 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 5508.35 | 5508.35 | 0.305010 | 19.84 | 14.89 | 0.00880060 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 8.5094 | 21.10 | 0.00901592 | 56.3744 | 236.26 | 0.00 | -999.00 | -999.00 |
| SPLIT GS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GS1 | 5600.845 | 4481.141 | 0.306531 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 5028.32 | 4805.13 | 0.306531 | 26.17 | 16.71 | 0.00829454 | 12.80 | 11.37 | 0.00800000 | 38.22 | 0.00915158 | 21.18 | 8.4672 | 24.00 | 0.00821526 | 43.1292 | 3537.84 | 0.00 | 5599.89 | 4417.99 |
| SPLIT GS1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT GS1 | 5600.845 | 5600.845 | 0.306531 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 5600.84 | 5600.84 | 0.306531 | 19.85 | 13.99 | 0.00780937 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 8.4672 | 21.10 | 0.00796398 | 49.8810 | 350.26 | 0.00 | 5608.20 | 5608.20 |
| SPLIT GS1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT GS1 | 5600.845 | 5600.845 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 5600.84 | 5600.84 | 0.306531 | 19.85 | 13.99 | 0.00780937 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 8.4672 | 21.10 | 0.00796398 | 49.8810 | 350.26 | 0.00 | -999.00 | -999.00 |
| SPLIT GS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT GS2 | 5649.039 | 4521.636 | 0.309487 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 5070.67 | 4847.36 | 0.309487 | 26.16 | 16.70 | 0.00829194 | 12.80 | 11.37 | 0.00800000 | 38.22 | 0.00915158 | 21.18 | 8.3863 | 24.00 | 0.00821325 | 43.1188 | 3570.98 | 0.00 | 5648.08 | 4457.96 |
| SPLIT GS2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT GS2 | 5649.039 | 5649.039 | 0.309487 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 5649.04 | 5649.04 | 0.309487 | 19.86 | 14.00 | 0.00781125 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 8.3863 | 21.10 | 0.00796502 | 49.8874 | 359.56 | 0.00 | 5656.46 | 5656.46 |
| SPLIT GS2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT GS2 | 5649.039 | 5649.039 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 5649.04 | 5649.04 | 0.309487 | 19.86 | 14.00 | 0.00781125 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 8.3863 | 21.10 | 0.00796502 | 49.8874 | 359.56 | 0.00 | -999.00 | -999.00 |
| SPLIT MSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MSW | 14359.571 | 11500.832 | 0.811454 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 12821.42 | 12439.32 | 0.811454 | 25.89 | 16.53 | 0.00819144 | 12.80 | 11.37 | 0.00800000 | 38.22 | 0.00915158 | 21.18 | 6.3970 | 24.00 | 0.00812582 | 42.6650 | 18607.98 | 0.00 | 14357.13 | 11339.72 |
| SPLIT MSW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MSW | 14359.571 | 14359.571 | 0.811454 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 14359.57 | 14359.57 | 0.811454 | 20.15 | 14.14 | 0.00784531 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 6.3970 | 21.10 | 0.00796648 | 49.8965 | 3191.72 | 0.00 | 14378.44 | 14378.44 |
| SPLIT MSW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MSW | 14359.571 | 14359.571 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 14359.57 | 14359.57 | 0.811454 | 20.15 | 14.14 | 0.00784531 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 6.3970 | 21.10 | 0.00796648 | 49.8965 | 3191.72 | 0.00 | -999.00 | -999.00 |
| SPLIT MNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MNW | 14260.499 | 11417.249 | 0.809846 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 12722.83 | 12405.71 | 0.809846 | 25.90 | 16.50 | 0.00815933 | 12.80 | 11.37 | 0.00800000 | 38.22 | 0.00915158 | 21.18 | 6.4098 | 24.00 | 0.00809137 | 42.4861 | 18572.07 | 0.00 | 14258.07 | 11255.74 |
| SPLIT MNW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MNW | 14260.499 | 14260.499 | 0.809846 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 14260.50 | 14260.50 | 0.809846 | 20.15 | 14.55 | 0.00829356 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 6.4098 | 21.10 | 0.00844569 | 52.8565 | 2639.09 | 0.00 | 14279.24 | 14279.24 |
| SPLIT MNW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MNW | 14260.499 | 14260.499 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 14260.50 | 14260.50 | 0.809846 | 20.15 | 14.55 | 0.00829356 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 6.4098 | 21.10 | 0.00844569 | 52.8565 | 2639.09 | 0.00 | -999.00 | -999.00 |
| SPLIT MSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MSE | 13838.859 | 11076.572 | 0.778570 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 12365.71 | 11970.82 | 0.778570 | 25.93 | 16.55 | 0.00820606 | 12.80 | 11.37 | 0.00800000 | 38.22 | 0.00915158 | 21.18 | 6.6672 | 24.00 | 0.00813851 | 42.7309 | 17868.30 | 0.00 | 13836.50 | 10921.10 |
| SPLIT MSE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MSE | 13838.859 | 13838.859 | 0.778570 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 13838.86 | 13838.86 | 0.778570 | 20.11 | 14.12 | 0.00784017 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 6.6672 | 21.10 | 0.00796645 | 49.8964 | 3189.61 | 0.00 | 13857.04 | 13857.04 |
| SPLIT MSE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MSE | 13838.859 | 13838.859 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 13838.86 | 13838.86 | 0.778570 | 20.11 | 14.12 | 0.00784017 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 6.6672 | 21.10 | 0.00796645 | 49.8964 | 3189.61 | 0.00 | -999.00 | -999.00 |
| SPLIT MNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MNE | 13731.437 | 10990.376 | 0.777003 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 12258.25 | 11936.56 | 0.777003 | 25.93 | 16.52 | 0.00816837 | 12.80 | 11.37 | 0.00800000 | 38.22 | 0.00915158 | 21.18 | 6.6807 | 24.00 | 0.00809798 | 42.5204 | 17833.39 | 0.00 | 13729.10 | 10836.90 |
| SPLIT MNE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MNE | 13731.437 | 13731.437 | 0.777003 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 13731.44 | 13731.44 | 0.777003 | 20.11 | 14.53 | 0.00828749 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 6.6807 | 21.10 | 0.00844607 | 52.8589 | 2636.80 | 0.00 | 13749.48 | 13749.48 |
| SPLIT MNE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MNE | 13731.437 | 13731.437 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 13731.44 | 13731.44 | 0.777003 | 20.11 | 14.53 | 0.00828749 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 6.6807 | 21.10 | 0.00844607 | 52.8589 | 2636.80 | 0.00 | -999.00 | -999.00 |
| SPLIT MN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MN1 | 11967.750 | 9582.674 | 0.668015 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 10708.74 | 10380.01 | 0.668015 | 26.08 | 16.60 | 0.00819970 | 12.80 | 11.37 | 0.00800000 | 38.22 | 0.00915158 | 21.18 | 7.7706 | 24.00 | 0.00811950 | 42.6320 | 15391.58 | 0.00 | 11965.71 | 9446.96 |
| SPLIT MN1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MN1 | 11967.750 | 11967.750 | 0.668015 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 11967.75 | 11967.75 | 0.668015 | 19.95 | 15.00 | 0.00888281 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 7.7706 | 21.10 | 0.00912107 | 57.0225 | 829.73 | 0.00 | 11983.48 | 11983.48 |
| SPLIT MN1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MN1 | 11967.750 | 11967.750 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 11967.75 | 11967.75 | 0.668015 | 19.95 | 15.00 | 0.00888281 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 7.7706 | 21.10 | 0.00912107 | 57.0225 | 829.73 | 0.00 | -999.00 | -999.00 |
| SPLIT MN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MN2 | 11959.056 | 9575.386 | 0.667476 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 10701.11 | 10372.32 | 0.667476 | 26.08 | 16.60 | 0.00819990 | 12.80 | 11.37 | 0.00800000 | 38.22 | 0.00915158 | 21.18 | 7.7769 | 24.00 | 0.00811965 | 42.6327 | 15379.54 | 0.00 | 11957.02 | 9439.78 |
| SPLIT MN2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MN2 | 11959.056 | 11959.056 | 0.667476 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 11959.06 | 11959.06 | 0.667476 | 19.95 | 15.00 | 0.00888268 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 7.7769 | 21.10 | 0.00912114 | 57.0229 | 829.67 | 0.00 | 11974.77 | 11974.77 |
| SPLIT MN2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MN2 | 11959.056 | 11959.056 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 11959.06 | 11959.06 | 0.667476 | 19.95 | 15.00 | 0.00888268 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 7.7769 | 21.10 | 0.00912114 | 57.0229 | 829.67 | 0.00 | -999.00 | -999.00 |
| SPLIT MS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MS1 | 12132.367 | 9710.283 | 0.670533 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 10873.70 | 10433.57 | 0.670533 | 26.08 | 16.65 | 0.00826592 | 12.80 | 11.37 | 0.00800000 | 38.22 | 0.00915158 | 21.18 | 7.7415 | 24.00 | 0.00819161 | 43.0064 | 15447.52 | 0.00 | 12130.30 | 9571.28 |
| SPLIT MS1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MS1 | 12132.367 | 12132.367 | 0.670533 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 17:30:00 | 12132.37 | 12132.37 | 0.670533 | 19.95 | 14.03 | 0.00780943 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 7.7415 | 21.10 | 0.00794280 | 49.7501 | 1316.53 | 0.00 | 12148.31 | 12148.31 |
| SPLIT MS1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MS1 | 12132.367 | 12132.367 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 17:30:00 | 12132.37 | 12132.37 | 0.670533 | 19.95 | 14.03 | 0.00780943 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 7.7415 | 21.10 | 0.00794280 | 49.7501 | 1316.53 | 0.00 | -999.00 | -999.00 |
| SPLIT MS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT MS2 | 12123.759 | 9702.978 | 0.669989 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 10866.17 | 10425.83 | 0.669989 | 26.08 | 16.65 | 0.00826627 | 12.80 | 11.37 | 0.00800000 | 38.22 | 0.00915158 | 21.18 | 7.7478 | 24.00 | 0.00819191 | 43.0080 | 15435.36 | 0.00 | 12121.70 | 9564.07 |
| SPLIT MS2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT MS2 | 12123.759 | 12123.759 | 0.669989 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 12123.76 | 12123.76 | 0.669989 | 19.95 | 14.03 | 0.00780931 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 7.7478 | 21.10 | 0.00794280 | 49.7500 | 1316.48 | 0.00 | 12139.69 | 12139.69 |
| SPLIT MS2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT MS2 | 12123.759 | 12123.759 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 12123.76 | 12123.76 | 0.669989 | 19.95 | 14.03 | 0.00780931 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 7.7478 | 21.10 | 0.00794280 | 49.7500 | 1316.48 | 0.00 | -999.00 | -999.00 |
| SPLIT TSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TSW | 7873.362 | 6300.328 | 0.449178 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 7018.81 | 6841.05 | 0.449178 | 25.82 | 16.48 | 0.00816113 | 12.80 | 11.37 | 0.00800000 | 38.22 | 0.00915158 | 21.18 | 5.7782 | 24.00 | 0.00810039 | 42.5330 | 5144.55 | 0.00 | 7872.02 | 6210.35 |
| SPLIT TSW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TSW | 7873.362 | 7873.362 | 0.449178 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 7873.36 | 7873.36 | 0.449178 | 20.24 | 14.19 | 0.00786458 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 5.7782 | 21.10 | 0.00797449 | 49.9461 | 1358.04 | 0.00 | 7883.71 | 7883.71 |
| SPLIT TSW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TSW | 7873.362 | 7873.362 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 7873.36 | 7873.36 | 0.449178 | 20.24 | 14.19 | 0.00786458 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 5.7782 | 21.10 | 0.00797449 | 49.9461 | 1358.04 | 0.00 | -999.00 | -999.00 |
| SPLIT TNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TNW | 7871.048 | 6299.716 | 0.450543 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 7012.99 | 6856.94 | 0.450543 | 25.81 | 16.46 | 0.00814111 | 12.80 | 11.37 | 0.00800000 | 38.22 | 0.00915158 | 21.18 | 5.7607 | 24.00 | 0.00807935 | 42.4237 | 5159.89 | 0.00 | 7869.71 | 6209.85 |
| SPLIT TNW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TNW | 7871.048 | 7871.048 | 0.450543 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 7871.05 | 7871.05 | 0.450543 | 20.25 | 14.42 | 0.00811104 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 5.7607 | 21.10 | 0.00823566 | 51.5593 | 1210.35 | 0.00 | 7881.39 | 7881.39 |
| SPLIT TNW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TNW | 7871.048 | 7871.048 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 7871.05 | 7871.05 | 0.450543 | 20.25 | 14.42 | 0.00811104 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 5.7607 | 21.10 | 0.00823566 | 51.5593 | 1210.35 | 0.00 | -999.00 | -999.00 |
| SPLIT TSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TSE | 7495.581 | 6001.455 | 0.425726 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 6687.03 | 6506.08 | 0.425726 | 25.86 | 16.50 | 0.00817294 | 12.80 | 11.37 | 0.00800000 | 38.22 | 0.00915158 | 21.18 | 6.0965 | 24.00 | 0.00810940 | 42.5798 | 4880.31 | 0.00 | 7494.30 | 5916.55 |
| SPLIT TSE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TSE | 7495.581 | 7495.581 | 0.425726 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 7495.58 | 7495.58 | 0.425726 | 20.20 | 14.17 | 0.00785851 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 6.0965 | 21.10 | 0.00797448 | 49.9460 | 1357.37 | 0.00 | 7505.43 | 7505.43 |
| SPLIT TSE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TSE | 7495.581 | 7495.581 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 7495.58 | 7495.58 | 0.425726 | 20.20 | 14.17 | 0.00785851 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 6.0965 | 21.10 | 0.00797448 | 49.9460 | 1357.37 | 0.00 | -999.00 | -999.00 |
| SPLIT TNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TNE | 7490.686 | 5999.939 | 0.427073 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 6678.55 | 6521.43 | 0.427073 | 25.86 | 16.48 | 0.00814979 | 12.80 | 11.37 | 0.00800000 | 38.22 | 0.00915158 | 21.18 | 6.0773 | 24.00 | 0.00808496 | 42.4528 | 4895.54 | 0.00 | 7489.41 | 5913.92 |
| SPLIT TNE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TNE | 7490.686 | 7490.686 | 0.427073 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 7490.69 | 7490.69 | 0.427073 | 20.20 | 14.40 | 0.00810433 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 6.0773 | 21.10 | 0.00823581 | 51.5602 | 1209.62 | 0.00 | 7500.53 | 7500.53 |
| SPLIT TNE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TNE | 7490.686 | 7490.686 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 7490.69 | 7490.69 | 0.427073 | 20.20 | 14.40 | 0.00810433 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 6.0773 | 21.10 | 0.00823581 | 51.5602 | 1209.62 | 0.00 | -999.00 | -999.00 |
| SPLIT TN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TN1 | 6728.078 | 5383.542 | 0.380470 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 6006.98 | 5853.97 | 0.380470 | 25.96 | 16.53 | 0.00816354 | 12.80 | 11.37 | 0.00800000 | 38.22 | 0.00915158 | 21.18 | 6.8217 | 24.00 | 0.00809120 | 42.4851 | 4370.43 | 0.00 | 6726.93 | 5308.39 |
| SPLIT TN1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TN1 | 6728.078 | 6728.078 | 0.380470 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6728.08 | 6728.08 | 0.380470 | 20.09 | 14.46 | 0.00821790 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 6.8217 | 21.10 | 0.00837498 | 52.4198 | 806.42 | 0.00 | 6736.92 | 6736.92 |
| SPLIT TN1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TN1 | 6728.078 | 6728.078 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6728.08 | 6728.08 | 0.380470 | 20.09 | 14.46 | 0.00821790 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 6.8217 | 21.10 | 0.00837498 | 52.4198 | 806.42 | 0.00 | -999.00 | -999.00 |
| SPLIT TN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TN2 | 6715.582 | 5373.150 | 0.379698 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 5996.00 | 5842.94 | 0.379698 | 25.96 | 16.53 | 0.00816391 | 12.80 | 11.37 | 0.00800000 | 38.22 | 0.00915158 | 21.18 | 6.8356 | 24.00 | 0.00809144 | 42.4864 | 4361.75 | 0.00 | 6714.44 | 5298.15 |
| SPLIT TN2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TN2 | 6715.582 | 6715.582 | 0.379698 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6715.58 | 6715.58 | 0.379698 | 20.09 | 14.46 | 0.00821759 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 6.8356 | 21.10 | 0.00837499 | 52.4199 | 806.40 | 0.00 | 6724.41 | 6724.41 |
| SPLIT TN2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TN2 | 6715.582 | 6715.582 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6715.58 | 6715.58 | 0.379698 | 20.09 | 14.46 | 0.00821759 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 6.8356 | 21.10 | 0.00837499 | 52.4199 | 806.40 | 0.00 | -999.00 | -999.00 |
| SPLIT TS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TS1 | 6742.384 | 5396.595 | 0.379327 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 6024.78 | 5842.41 | 0.379327 | 25.96 | 16.55 | 0.00819533 | 12.80 | 11.37 | 0.00800000 | 38.22 | 0.00915158 | 21.18 | 6.8423 | 24.00 | 0.00812509 | 42.6612 | 4357.54 | 0.00 | 6741.24 | 5320.85 |
| SPLIT TS1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TS1 | 6742.384 | 6742.384 | 0.379327 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6742.38 | 6742.38 | 0.379327 | 20.09 | 14.12 | 0.00784737 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 6.8423 | 21.10 | 0.00797774 | 49.9661 | 955.04 | 0.00 | 6751.24 | 6751.24 |
| SPLIT TS1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TS1 | 6742.384 | 6742.384 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6742.38 | 6742.38 | 0.379327 | 20.09 | 14.12 | 0.00784737 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 6.8423 | 21.10 | 0.00797774 | 49.9661 | 955.04 | 0.00 | -999.00 | -999.00 |
| SPLIT TS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoopHVAC | SPLIT TS2 | 6730.016 | 5386.245 | 0.378557 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | 6013.92 | 5831.42 | 0.378557 | 25.96 | 16.56 | 0.00819587 | 12.80 | 11.37 | 0.00800000 | 38.22 | 0.00915158 | 21.18 | 6.8562 | 24.00 | 0.00812552 | 42.6634 | 4348.88 | 0.00 | 6728.87 | 5310.65 |
| SPLIT TS2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoopHVAC | SPLIT TS2 | 6730.016 | 6730.016 | 0.378557 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6730.02 | 6730.02 | 0.378557 | 20.09 | 14.12 | 0.00784710 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 6.8562 | 21.10 | 0.00797774 | 49.9661 | 955.02 | 0.00 | 6738.86 | 6738.86 |
| SPLIT TS2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoopHVAC | SPLIT TS2 | 6730.016 | 6730.016 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | 6730.02 | 6730.02 | 0.378557 | 20.09 | 14.12 | 0.00784710 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 6.8562 | 21.10 | 0.00797774 | 49.9661 | 955.02 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Coils| Coil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
| SPLIT GSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6512.197 | 5213.924 | 0.364495 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.1132 | 1004.8586 | 1.1738 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.364495 | 0.42783844 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | Sensible | 5824.11 | 5630.14 | 0.8943 | 0.42783844 | 0.364495 | 25.99 | 16.58 | 0.00821604 | 47060.9 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 408.273 | 5415.84 | 38.22 | 0.00915158 | 21.18 | 0.02595455 | 7.1207 | 24.05 | 0.00814431 | 24.00 | 0.00814431 | 42.7611 | 4188.84 | 0.00 | 6511.09 | 5140.31 | 0.41094206 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.44 | 14.08 | 0.00987681 | 39478.1 | |
| SPLIT GSW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 6512.197 | 6512.197 | 0.364495 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.364495 | 0.42783844 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 6512.20 | 6512.20 | 1.0000 | 0.42783844 | 0.364495 | 20.05 | 14.10 | 0.00783910 | 40040.4 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6512.20 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 7.1207 | 21.10 | 0.00797456 | 21.10 | 0.00797456 | 49.9465 | 729.79 | 0.00 | 6520.75 | 6520.75 | 0.42027840 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.31 | 20.62 | 0.00875166 | 58959.4 | |
| SPLIT GSW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT GSW | G SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6512.197 | 6512.197 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.364495 | 0.42783844 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 6512.20 | 6512.20 | 1.0000 | 0.42783844 | 0.364495 | 20.05 | 14.10 | 0.00783910 | 40040.4 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6512.20 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 7.1207 | 21.10 | 0.00797456 | 21.10 | 0.00797456 | 49.9465 | 729.79 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6457.757 | 5171.500 | 0.363761 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.0354 | 1004.8586 | 1.1738 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.363761 | 0.42697694 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | Sensible | 5769.44 | 5613.52 | 0.8934 | 0.42697694 | 0.363761 | 25.99 | 16.55 | 0.00817419 | 46956.4 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 407.451 | 5361.99 | 38.22 | 0.00915158 | 21.18 | 0.02595455 | 7.1351 | 24.05 | 0.00809909 | 24.00 | 0.00809909 | 42.5262 | 4180.70 | 0.00 | 6456.66 | 5098.88 | 0.41011458 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.52 | 14.12 | 0.00988660 | 39578.8 | |
| SPLIT GNW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 6457.757 | 6457.757 | 0.363761 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.363761 | 0.42697694 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | Sensible | 6457.76 | 6457.76 | 1.0000 | 0.42697694 | 0.363761 | 20.04 | 14.54 | 0.00832072 | 41261.0 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6457.76 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 7.1351 | 21.10 | 0.00849347 | 21.10 | 0.00849347 | 53.1514 | 608.76 | 0.00 | 6466.24 | 6466.24 | 0.41943213 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.21 | 20.59 | 0.00875166 | 58860.8 | |
| SPLIT GNW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT GNW | G NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6457.757 | 6457.757 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.363761 | 0.42697694 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | Sensible | 6457.76 | 6457.76 | 1.0000 | 0.42697694 | 0.363761 | 20.04 | 14.54 | 0.00832072 | 41261.0 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6457.76 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 7.1351 | 21.10 | 0.00849347 | 21.10 | 0.00849347 | 53.1514 | 608.76 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT OFFICE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7362.061 | 5894.893 | 0.425456 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.9202 | 1004.8586 | 1.1738 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.425456 | 0.49939460 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 09:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 09:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 09:00:00 | Sensible | 6691.56 | 6574.20 | 0.9089 | 0.49939460 | 0.425456 | 26.03 | 16.51 | 0.00811224 | 46840.5 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 476.557 | 6215.00 | 36.66 | 0.00914901 | 20.73 | 0.03810604 | 8.9565 | 23.96 | 0.00801025 | 23.90 | 0.00801025 | 42.3183 | 4816.11 | 0.00 | 7360.81 | 5811.00 | 0.47967228 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.83 | 14.27 | 0.00991787 | 39976.9 | |
| SPLIT OFFICE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 7362.061 | 7362.061 | 0.425456 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.425456 | 0.49939460 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | Sensible | 7362.06 | 7362.06 | 1.0000 | 0.49939460 | 0.425456 | 19.77 | 13.97 | 0.00781103 | 39692.2 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7362.06 | 6.30 | 0.00607234 | 6.30 | 0.03810604 | 8.9565 | 21.10 | 0.00798207 | 21.10 | 0.00798207 | 49.9929 | 1040.03 | 0.00 | 7371.74 | 7371.74 | 0.49057014 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 35.83 | 20.48 | 0.00875166 | 58471.0 | |
| SPLIT OFFICE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT OFFICE | OFFICE | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7362.061 | 7362.061 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.425456 | 0.49939460 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 18:50:00 | Sensible | 7362.06 | 7362.06 | 1.0000 | 0.49939460 | 0.425456 | 19.77 | 13.97 | 0.00781103 | 39692.2 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7362.06 | 6.30 | 0.00607234 | 6.30 | 0.03810604 | 8.9565 | 21.10 | 0.00798207 | 21.10 | 0.00798207 | 49.9929 | 1040.03 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6243.278 | 4998.303 | 0.350417 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.0522 | 1004.8586 | 1.1738 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.350417 | 0.41131446 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | Sensible | 5581.24 | 5423.16 | 0.8940 | 0.41131446 | 0.350417 | 26.03 | 16.57 | 0.00818323 | 47016.9 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 392.505 | 5188.73 | 38.22 | 0.00915158 | 21.18 | 0.02595455 | 7.4068 | 24.04 | 0.00810577 | 24.00 | 0.00810577 | 42.5608 | 4031.35 | 0.00 | 6242.22 | 4927.94 | 0.39507064 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.48 | 14.10 | 0.00988035 | 39522.1 | |
| SPLIT GNE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 6243.278 | 6243.278 | 0.350417 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.350417 | 0.41131446 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | Sensible | 6243.28 | 6243.28 | 1.0000 | 0.41131446 | 0.350417 | 20.00 | 14.51 | 0.00831444 | 41204.1 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6243.28 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 7.4068 | 21.10 | 0.00849379 | 21.10 | 0.00849379 | 53.1534 | 608.34 | 0.00 | 6251.48 | 6251.48 | 0.40404640 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.26 | 20.61 | 0.00875166 | 58916.3 | |
| SPLIT GNE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT GNE | G NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6243.278 | 6243.278 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.350417 | 0.41131446 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | Sensible | 6243.28 | 6243.28 | 1.0000 | 0.41131446 | 0.350417 | 20.00 | 14.51 | 0.00831444 | 41204.1 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6243.28 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 7.4068 | 21.10 | 0.00849379 | 21.10 | 0.00849379 | 53.1534 | 608.34 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5512.094 | 4409.805 | 0.305242 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.1112 | 1004.8586 | 1.1738 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.305242 | 0.35828909 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | Sensible | 4939.01 | 4777.12 | 0.8960 | 0.35828909 | 0.305242 | 26.17 | 16.65 | 0.00821498 | 47246.4 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 341.904 | 4597.11 | 38.22 | 0.00915158 | 21.18 | 0.02595455 | 8.5029 | 24.03 | 0.00812794 | 24.00 | 0.00812794 | 42.6758 | 3523.39 | 0.00 | 5511.16 | 4346.90 | 0.34413938 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.32 | 14.02 | 0.00985822 | 39308.1 | |
| SPLIT GN1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5512.094 | 5512.094 | 0.305242 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.305242 | 0.35828909 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 5512.09 | 5512.09 | 1.0000 | 0.35828909 | 0.305242 | 19.84 | 14.89 | 0.00880075 | 42272.7 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5512.09 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 8.5029 | 21.10 | 0.00905431 | 21.10 | 0.00901588 | 56.3742 | 236.27 | 0.00 | 5519.34 | 5519.34 | 0.35195802 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.47 | 20.67 | 0.00875166 | 59125.9 | |
| SPLIT GN1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT GN1 | G N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5512.094 | 5512.094 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.305242 | 0.35828909 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 5512.09 | 5512.09 | 1.0000 | 0.35828909 | 0.305242 | 19.84 | 14.89 | 0.00880075 | 42272.7 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5512.09 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 8.5029 | 21.10 | 0.00905431 | 21.10 | 0.00901588 | 56.3742 | 236.27 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5508.348 | 4412.167 | 0.305010 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.1116 | 1004.8586 | 1.1738 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.305010 | 0.35801686 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | Sensible | 4935.73 | 4773.80 | 0.8960 | 0.35801686 | 0.305010 | 26.18 | 16.65 | 0.00821518 | 47247.8 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 341.645 | 4594.08 | 38.22 | 0.00915158 | 21.18 | 0.02595455 | 8.5094 | 24.03 | 0.00812809 | 24.00 | 0.00812809 | 42.6766 | 3520.77 | 0.00 | 5507.41 | 4349.05 | 0.34387790 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.31 | 14.02 | 0.00986394 | 39306.8 | |
| SPLIT GN2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5508.348 | 5508.348 | 0.305010 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.305010 | 0.35801686 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 5508.35 | 5508.35 | 1.0000 | 0.35801686 | 0.305010 | 19.84 | 14.89 | 0.00880060 | 42271.4 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5508.35 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 8.5094 | 21.10 | 0.00905436 | 21.10 | 0.00901592 | 56.3744 | 236.26 | 0.00 | 5515.59 | 5515.59 | 0.35169059 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.47 | 20.67 | 0.00875166 | 59127.2 | |
| SPLIT GN2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT GN2 | G N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5508.348 | 5508.348 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.305010 | 0.35801686 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 5508.35 | 5508.35 | 1.0000 | 0.35801686 | 0.305010 | 19.84 | 14.89 | 0.00880060 | 42271.4 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5508.35 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 8.5094 | 21.10 | 0.00905436 | 21.10 | 0.00901592 | 56.3744 | 236.26 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5600.845 | 4481.141 | 0.306531 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.2591 | 1004.8586 | 1.1738 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.306531 | 0.35980148 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | Sensible | 5028.32 | 4805.13 | 0.8978 | 0.35980148 | 0.306531 | 26.17 | 16.71 | 0.00829454 | 47444.1 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 343.348 | 4684.97 | 38.22 | 0.00915158 | 21.18 | 0.02595455 | 8.4672 | 24.03 | 0.00821526 | 24.00 | 0.00821526 | 43.1292 | 3537.84 | 0.00 | 5599.89 | 4417.99 | 0.34559204 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.17 | 13.95 | 0.00984378 | 39118.6 | |
| SPLIT GS1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5600.845 | 5600.845 | 0.306531 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.306531 | 0.35980148 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 5600.84 | 5600.84 | 1.0000 | 0.35980148 | 0.306531 | 19.85 | 13.99 | 0.00780937 | 39761.8 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5600.84 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 8.4672 | 21.10 | 0.00797005 | 21.10 | 0.00796398 | 49.8810 | 350.26 | 0.00 | 5608.20 | 5608.20 | 0.35344367 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.65 | 20.73 | 0.00875166 | 59311.4 | |
| SPLIT GS1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT GS1 | G S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5600.845 | 5600.845 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.306531 | 0.35980148 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 5600.84 | 5600.84 | 1.0000 | 0.35980148 | 0.306531 | 19.85 | 13.99 | 0.00780937 | 39761.8 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5600.84 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 8.4672 | 21.10 | 0.00797005 | 21.10 | 0.00796398 | 49.8810 | 350.26 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT GS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 5649.039 | 4521.636 | 0.309487 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.2543 | 1004.8586 | 1.1738 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.309487 | 0.36327078 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | Sensible | 5070.67 | 4847.36 | 0.8976 | 0.36327078 | 0.309487 | 26.16 | 16.70 | 0.00829194 | 47426.2 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 346.658 | 4724.01 | 38.22 | 0.00915158 | 21.18 | 0.02595455 | 8.3863 | 24.03 | 0.00821325 | 24.00 | 0.00821325 | 43.1188 | 3570.98 | 0.00 | 5648.08 | 4457.96 | 0.34892433 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.18 | 13.95 | 0.00984736 | 39135.3 | |
| SPLIT GS2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 5649.039 | 5649.039 | 0.309487 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.309487 | 0.36327078 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 5649.04 | 5649.04 | 1.0000 | 0.36327078 | 0.309487 | 19.86 | 14.00 | 0.00781125 | 39778.8 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5649.04 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 8.3863 | 21.10 | 0.00797043 | 21.10 | 0.00796502 | 49.8874 | 359.56 | 0.00 | 5656.46 | 5656.46 | 0.35685168 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.63 | 20.72 | 0.00875166 | 59295.1 | |
| SPLIT GS2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT GS2 | G S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5649.039 | 5649.039 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.309487 | 0.36327078 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 5649.04 | 5649.04 | 1.0000 | 0.36327078 | 0.309487 | 19.86 | 14.00 | 0.00781125 | 39778.8 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5649.04 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 8.3863 | 21.10 | 0.00797043 | 21.10 | 0.00796502 | 49.8874 | 359.56 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 14359.571 | 11500.832 | 0.811454 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.0675 | 1004.8586 | 1.1738 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.811454 | 0.95247276 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | Sensible | 12821.42 | 12439.32 | 0.8929 | 0.95247276 | 0.811454 | 25.89 | 16.53 | 0.00819144 | 46899.9 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 908.916 | 11912.51 | 38.22 | 0.00915158 | 21.18 | 0.05190911 | 6.3970 | 24.05 | 0.00812582 | 24.00 | 0.00812582 | 42.6650 | 18607.98 | 0.00 | 14357.13 | 11339.72 | 0.91485729 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.55 | 14.14 | 0.00989150 | 39629.1 | |
| SPLIT MSW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 14359.571 | 14359.571 | 0.811454 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.811454 | 0.95247276 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 14359.57 | 14359.57 | 1.0000 | 0.95247276 | 0.811454 | 20.15 | 14.14 | 0.00784531 | 40165.3 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 14359.57 | 6.30 | 0.00607234 | 6.30 | 0.05190911 | 6.3970 | 21.10 | 0.00796648 | 21.10 | 0.00796648 | 49.8965 | 3191.72 | 0.00 | 14378.44 | 14378.44 | 0.93564227 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.16 | 20.58 | 0.00875166 | 58811.6 | |
| SPLIT MSW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MSW | M SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 14359.571 | 14359.571 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.811454 | 0.95247276 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 14359.57 | 14359.57 | 1.0000 | 0.95247276 | 0.811454 | 20.15 | 14.14 | 0.00784531 | 40165.3 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 14359.57 | 6.30 | 0.00607234 | 6.30 | 0.05190911 | 6.3970 | 21.10 | 0.00796648 | 21.10 | 0.00796648 | 49.8965 | 3191.72 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 14260.499 | 11417.249 | 0.809846 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.0078 | 1004.8586 | 1.1738 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.809846 | 0.95058527 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | Sensible | 12722.83 | 12405.71 | 0.8922 | 0.95058527 | 0.809846 | 25.90 | 16.50 | 0.00815933 | 46820.0 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 907.115 | 11815.72 | 38.22 | 0.00915158 | 21.18 | 0.05190911 | 6.4098 | 24.05 | 0.00809137 | 24.00 | 0.00809137 | 42.4861 | 18572.07 | 0.00 | 14258.07 | 11255.74 | 0.91304434 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.62 | 14.17 | 0.00989541 | 39706.4 | |
| SPLIT MNW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 14260.499 | 14260.499 | 0.809846 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.809846 | 0.95058527 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 14260.50 | 14260.50 | 1.0000 | 0.95058527 | 0.809846 | 20.15 | 14.55 | 0.00829356 | 41301.6 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 14260.50 | 6.30 | 0.00607234 | 6.30 | 0.05190911 | 6.4098 | 21.10 | 0.00844569 | 21.10 | 0.00844569 | 52.8565 | 2639.09 | 0.00 | 14279.24 | 14279.24 | 0.93378813 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.09 | 20.56 | 0.00875166 | 58735.8 | |
| SPLIT MNW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MNW | M NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 14260.499 | 14260.499 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.809846 | 0.95058527 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 14260.50 | 14260.50 | 1.0000 | 0.95058527 | 0.809846 | 20.15 | 14.55 | 0.00829356 | 41301.6 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 14260.50 | 6.30 | 0.00607234 | 6.30 | 0.05190911 | 6.4098 | 21.10 | 0.00844569 | 21.10 | 0.00844569 | 52.8565 | 2639.09 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 13838.859 | 11076.572 | 0.778570 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.0947 | 1004.8586 | 1.1738 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.778570 | 0.91387363 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | Sensible | 12365.71 | 11970.82 | 0.8935 | 0.91387363 | 0.778570 | 25.93 | 16.55 | 0.00820606 | 46973.7 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 872.082 | 11493.63 | 38.22 | 0.00915158 | 21.18 | 0.05190911 | 6.6672 | 24.05 | 0.00813851 | 24.00 | 0.00813851 | 42.7309 | 17868.30 | 0.00 | 13836.50 | 10921.10 | 0.87778253 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.51 | 14.11 | 0.00988245 | 39559.4 | |
| SPLIT MSE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 13838.859 | 13838.859 | 0.778570 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.778570 | 0.91387363 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 13838.86 | 13838.86 | 1.0000 | 0.91387363 | 0.778570 | 20.11 | 14.12 | 0.00784017 | 40111.5 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 13838.86 | 6.30 | 0.00607234 | 6.30 | 0.05190911 | 6.6672 | 21.10 | 0.00796645 | 21.10 | 0.00796645 | 49.8964 | 3189.61 | 0.00 | 13857.04 | 13857.04 | 0.89772520 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.23 | 20.60 | 0.00875166 | 58879.8 | |
| SPLIT MSE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MSE | M SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 13838.859 | 13838.859 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.778570 | 0.91387363 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 13838.86 | 13838.86 | 1.0000 | 0.91387363 | 0.778570 | 20.11 | 14.12 | 0.00784017 | 40111.5 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 13838.86 | 6.30 | 0.00607234 | 6.30 | 0.05190911 | 6.6672 | 21.10 | 0.00796645 | 21.10 | 0.00796645 | 49.8964 | 3189.61 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 13731.437 | 10990.376 | 0.777003 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.0246 | 1004.8586 | 1.1738 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.777003 | 0.91203492 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | Sensible | 12258.25 | 11936.56 | 0.8927 | 0.91203492 | 0.777003 | 25.93 | 16.52 | 0.00816837 | 46879.8 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 870.327 | 11387.93 | 38.22 | 0.00915158 | 21.18 | 0.05190911 | 6.6807 | 24.05 | 0.00809798 | 24.00 | 0.00809798 | 42.5204 | 17833.39 | 0.00 | 13729.10 | 10836.90 | 0.87601644 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.58 | 14.15 | 0.00989020 | 39650.2 | |
| SPLIT MNE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 13731.437 | 13731.437 | 0.777003 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.777003 | 0.91203492 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 13731.44 | 13731.44 | 1.0000 | 0.91203492 | 0.777003 | 20.11 | 14.53 | 0.00828749 | 41245.3 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 13731.44 | 6.30 | 0.00607234 | 6.30 | 0.05190911 | 6.6807 | 21.10 | 0.00844607 | 21.10 | 0.00844607 | 52.8589 | 2636.80 | 0.00 | 13749.48 | 13749.48 | 0.89591898 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.14 | 20.57 | 0.00875166 | 58790.9 | |
| SPLIT MNE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MNE | M NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 13731.437 | 13731.437 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.777003 | 0.91203492 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 13731.44 | 13731.44 | 1.0000 | 0.91203492 | 0.777003 | 20.11 | 14.53 | 0.00828749 | 41245.3 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 13731.44 | 6.30 | 0.00607234 | 6.30 | 0.05190911 | 6.6807 | 21.10 | 0.00844607 | 21.10 | 0.00844607 | 52.8589 | 2636.80 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 11967.750 | 9582.674 | 0.668015 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.0828 | 1004.8586 | 1.1738 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.668015 | 0.78410669 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | Sensible | 10708.74 | 10380.01 | 0.8948 | 0.78410669 | 0.668015 | 26.08 | 16.60 | 0.00819970 | 47110.2 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 748.249 | 9960.49 | 38.22 | 0.00915158 | 21.18 | 0.05190911 | 7.7706 | 24.04 | 0.00811950 | 24.00 | 0.00811950 | 42.6320 | 15391.58 | 0.00 | 11965.71 | 9446.96 | 0.75314040 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.41 | 14.07 | 0.00987343 | 39434.6 | |
| SPLIT MN1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 11967.750 | 11967.750 | 0.668015 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.668015 | 0.78410669 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 11967.75 | 11967.75 | 1.0000 | 0.78410669 | 0.668015 | 19.95 | 15.00 | 0.00888281 | 42591.7 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11967.75 | 6.30 | 0.00607234 | 6.30 | 0.05190911 | 7.7706 | 21.10 | 0.00911960 | 21.10 | 0.00912107 | 57.0225 | 829.73 | 0.00 | 11983.48 | 11983.48 | 0.77025128 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.35 | 20.64 | 0.00875166 | 59002.0 | |
| SPLIT MN1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MN1 | M N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 11967.750 | 11967.750 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.668015 | 0.78410669 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 11967.75 | 11967.75 | 1.0000 | 0.78410669 | 0.668015 | 19.95 | 15.00 | 0.00888281 | 42591.7 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11967.75 | 6.30 | 0.00607234 | 6.30 | 0.05190911 | 7.7706 | 21.10 | 0.00911960 | 21.10 | 0.00912107 | 57.0225 | 829.73 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 11959.056 | 9575.386 | 0.667476 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.0832 | 1004.8586 | 1.1738 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.667476 | 0.78347405 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | Sensible | 10701.11 | 10372.32 | 0.8948 | 0.78347405 | 0.667476 | 26.08 | 16.60 | 0.00819990 | 47111.5 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 747.646 | 9953.47 | 38.22 | 0.00915158 | 21.18 | 0.05190911 | 7.7769 | 24.04 | 0.00811965 | 24.00 | 0.00811965 | 42.6327 | 15379.54 | 0.00 | 11957.02 | 9439.78 | 0.75253275 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.41 | 14.07 | 0.00987315 | 39433.3 | |
| SPLIT MN2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 11959.056 | 11959.056 | 0.667476 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.667476 | 0.78347405 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 11959.06 | 11959.06 | 1.0000 | 0.78347405 | 0.667476 | 19.95 | 15.00 | 0.00888268 | 42590.4 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11959.06 | 6.30 | 0.00607234 | 6.30 | 0.05190911 | 7.7769 | 21.10 | 0.00911967 | 21.10 | 0.00912114 | 57.0229 | 829.67 | 0.00 | 11974.77 | 11974.77 | 0.76962982 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.35 | 20.64 | 0.00875166 | 59003.2 | |
| SPLIT MN2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MN2 | M N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 11959.056 | 11959.056 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.667476 | 0.78347405 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 11959.06 | 11959.06 | 1.0000 | 0.78347405 | 0.667476 | 19.95 | 15.00 | 0.00888268 | 42590.4 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11959.06 | 6.30 | 0.00607234 | 6.30 | 0.05190911 | 7.7769 | 21.10 | 0.00911967 | 21.10 | 0.00912114 | 57.0229 | 829.67 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 12132.367 | 9710.283 | 0.670533 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.2059 | 1004.8586 | 1.1738 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.670533 | 0.78706201 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | Sensible | 10873.70 | 10433.57 | 0.8963 | 0.78706201 | 0.670533 | 26.08 | 16.65 | 0.00826592 | 47274.6 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 751.069 | 10122.63 | 38.22 | 0.00915158 | 21.18 | 0.05190911 | 7.7415 | 24.04 | 0.00819161 | 24.00 | 0.00819161 | 43.0064 | 15447.52 | 0.00 | 12130.30 | 9571.28 | 0.75597901 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.29 | 14.01 | 0.00985746 | 39276.6 | |
| SPLIT MS1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 12132.367 | 12132.367 | 0.670533 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.670533 | 0.78706201 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 17:30:00 | Sensible | 12132.37 | 12132.37 | 1.0000 | 0.78706201 | 0.670533 | 19.95 | 14.03 | 0.00780943 | 39871.4 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12132.37 | 6.30 | 0.00607234 | 6.30 | 0.05190911 | 7.7415 | 21.10 | 0.00795519 | 21.10 | 0.00794280 | 49.7501 | 1316.53 | 0.00 | 12148.31 | 12148.31 | 0.77315438 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.50 | 20.68 | 0.00875166 | 59156.8 | |
| SPLIT MS1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MS1 | M S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 12132.367 | 12132.367 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.670533 | 0.78706201 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 17:30:00 | Sensible | 12132.37 | 12132.37 | 1.0000 | 0.78706201 | 0.670533 | 19.95 | 14.03 | 0.00780943 | 39871.4 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12132.37 | 6.30 | 0.00607234 | 6.30 | 0.05190911 | 7.7415 | 21.10 | 0.00795519 | 21.10 | 0.00794280 | 49.7501 | 1316.53 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT MS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 12123.759 | 9702.978 | 0.669989 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.2066 | 1004.8586 | 1.1738 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.669989 | 0.78642341 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | Sensible | 10866.17 | 10425.83 | 0.8963 | 0.78642341 | 0.669989 | 26.08 | 16.65 | 0.00826627 | 47276.3 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 750.460 | 10115.71 | 38.22 | 0.00915158 | 21.18 | 0.05190911 | 7.7478 | 24.04 | 0.00819191 | 24.00 | 0.00819191 | 43.0080 | 15435.36 | 0.00 | 12121.70 | 9564.07 | 0.75536563 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.29 | 14.01 | 0.00985711 | 39274.9 | |
| SPLIT MS2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 12123.759 | 12123.759 | 0.669989 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.669989 | 0.78642341 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 12123.76 | 12123.76 | 1.0000 | 0.78642341 | 0.669989 | 19.95 | 14.03 | 0.00780931 | 39870.2 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12123.76 | 6.30 | 0.00607234 | 6.30 | 0.05190911 | 7.7478 | 21.10 | 0.00795519 | 21.10 | 0.00794280 | 49.7500 | 1316.48 | 0.00 | 12139.69 | 12139.69 | 0.77252706 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.50 | 20.68 | 0.00875166 | 59158.4 | |
| SPLIT MS2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT MS2 | M S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 12123.759 | 12123.759 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.669989 | 0.78642341 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 12123.76 | 12123.76 | 1.0000 | 0.78642341 | 0.669989 | 19.95 | 14.03 | 0.00780931 | 39870.2 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12123.76 | 6.30 | 0.00607234 | 6.30 | 0.05190911 | 7.7478 | 21.10 | 0.00795519 | 21.10 | 0.00794280 | 49.7500 | 1316.48 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TSW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7873.362 | 6300.328 | 0.449178 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.0111 | 1004.8586 | 1.1738 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.449178 | 0.52723810 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | Sensible | 7018.81 | 6841.05 | 0.8915 | 0.52723810 | 0.449178 | 25.82 | 16.48 | 0.00816113 | 46742.6 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 503.127 | 6515.68 | 38.22 | 0.00915158 | 21.18 | 0.02595455 | 5.7782 | 24.06 | 0.00810039 | 24.00 | 0.00810039 | 42.5330 | 5144.55 | 0.00 | 7872.02 | 6210.35 | 0.50641618 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.68 | 14.20 | 0.00989816 | 39777.8 | |
| SPLIT TSW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 7873.362 | 7873.362 | 0.449178 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.449178 | 0.52723810 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 7873.36 | 7873.36 | 1.0000 | 0.52723810 | 0.449178 | 20.24 | 14.19 | 0.00786458 | 40307.6 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7873.36 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 5.7782 | 21.10 | 0.00797449 | 21.10 | 0.00797449 | 49.9461 | 1358.04 | 0.00 | 7883.71 | 7883.71 | 0.51792164 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.02 | 20.54 | 0.00875166 | 58665.9 | |
| SPLIT TSW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TSW | T SW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7873.362 | 7873.362 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.449178 | 0.52723810 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 7873.36 | 7873.36 | 1.0000 | 0.52723810 | 0.449178 | 20.24 | 14.19 | 0.00786458 | 40307.6 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7873.36 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 5.7782 | 21.10 | 0.00797449 | 21.10 | 0.00797449 | 49.9461 | 1358.04 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TNW HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7871.048 | 6299.716 | 0.450543 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.9739 | 1004.8586 | 1.1738 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.450543 | 0.52884041 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | Sensible | 7012.99 | 6856.94 | 0.8910 | 0.52884041 | 0.450543 | 25.81 | 16.46 | 0.00814111 | 46689.2 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 504.656 | 6508.34 | 38.22 | 0.00915158 | 21.18 | 0.02595455 | 5.7607 | 24.06 | 0.00807935 | 24.00 | 0.00807935 | 42.4237 | 5159.89 | 0.00 | 7869.71 | 6209.85 | 0.50795521 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.72 | 14.21 | 0.00990346 | 39829.5 | |
| SPLIT TNW HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 7871.048 | 7871.048 | 0.450543 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.450543 | 0.52884041 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 7871.05 | 7871.05 | 1.0000 | 0.52884041 | 0.450543 | 20.25 | 14.42 | 0.00811104 | 40936.2 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7871.05 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 5.7607 | 21.10 | 0.00823566 | 21.10 | 0.00823566 | 51.5593 | 1210.35 | 0.00 | 7881.39 | 7881.39 | 0.51949564 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 35.97 | 20.52 | 0.00875166 | 58615.3 | |
| SPLIT TNW_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TNW | T NW APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7871.048 | 7871.048 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.450543 | 0.52884041 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 7871.05 | 7871.05 | 1.0000 | 0.52884041 | 0.450543 | 20.25 | 14.42 | 0.00811104 | 40936.2 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7871.05 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 5.7607 | 21.10 | 0.00823566 | 21.10 | 0.00823566 | 51.5593 | 1210.35 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TSE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7495.581 | 6001.455 | 0.425726 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.0331 | 1004.8586 | 1.1738 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.425726 | 0.49971053 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | Sensible | 6687.03 | 6506.08 | 0.8921 | 0.49971053 | 0.425726 | 25.86 | 16.50 | 0.00817294 | 46816.1 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 476.859 | 6210.17 | 38.22 | 0.00915158 | 21.18 | 0.02595455 | 6.0965 | 24.06 | 0.00810940 | 24.00 | 0.00810940 | 42.5798 | 4880.31 | 0.00 | 7494.30 | 5916.55 | 0.47997574 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.62 | 14.17 | 0.00989584 | 39708.5 | |
| SPLIT TSE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 7495.581 | 7495.581 | 0.425726 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.425726 | 0.49971053 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 7495.58 | 7495.58 | 1.0000 | 0.49971053 | 0.425726 | 20.20 | 14.17 | 0.00785851 | 40244.2 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7495.58 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 6.0965 | 21.10 | 0.00797448 | 21.10 | 0.00797448 | 49.9460 | 1357.37 | 0.00 | 7505.43 | 7505.43 | 0.49088049 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.08 | 20.56 | 0.00875166 | 58733.8 | |
| SPLIT TSE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TSE | T SE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7495.581 | 7495.581 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.425726 | 0.49971053 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 7495.58 | 7495.58 | 1.0000 | 0.49971053 | 0.425726 | 20.20 | 14.17 | 0.00785851 | 40244.2 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7495.58 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 6.0965 | 21.10 | 0.00797448 | 21.10 | 0.00797448 | 49.9460 | 1357.37 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TNE HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 7490.686 | 5999.939 | 0.427073 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.9900 | 1004.8586 | 1.1738 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.427073 | 0.50129231 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | Sensible | 6678.55 | 6521.43 | 0.8916 | 0.50129231 | 0.427073 | 25.86 | 16.48 | 0.00814979 | 46754.7 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 478.368 | 6200.18 | 38.22 | 0.00915158 | 21.18 | 0.02595455 | 6.0773 | 24.06 | 0.00808496 | 24.00 | 0.00808496 | 42.4528 | 4895.54 | 0.00 | 7489.41 | 5913.92 | 0.48149505 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.66 | 14.19 | 0.00990175 | 39767.9 | |
| SPLIT TNE HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 7490.686 | 7490.686 | 0.427073 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.427073 | 0.50129231 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 7490.69 | 7490.69 | 1.0000 | 0.50129231 | 0.427073 | 20.20 | 14.40 | 0.00810433 | 40871.4 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7490.69 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 6.0773 | 21.10 | 0.00823581 | 21.10 | 0.00823581 | 51.5602 | 1209.62 | 0.00 | 7500.53 | 7500.53 | 0.49243432 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.03 | 20.54 | 0.00875166 | 58675.6 | |
| SPLIT TNE_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TNE | T NE APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7490.686 | 7490.686 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.427073 | 0.50129231 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 7490.69 | 7490.69 | 1.0000 | 0.50129231 | 0.427073 | 20.20 | 14.40 | 0.00810433 | 40871.4 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7490.69 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 6.0773 | 21.10 | 0.00823581 | 21.10 | 0.00823581 | 51.5602 | 1209.62 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TN1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6728.078 | 5383.542 | 0.380470 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.0156 | 1004.8586 | 1.1738 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.380470 | 0.44658971 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | Sensible | 6006.98 | 5853.97 | 0.8928 | 0.44658971 | 0.380470 | 25.96 | 16.53 | 0.00816354 | 46891.2 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 426.167 | 5580.81 | 38.22 | 0.00915158 | 21.18 | 0.02595455 | 6.8217 | 24.05 | 0.00809120 | 24.00 | 0.00809120 | 42.4851 | 4370.43 | 0.00 | 6726.93 | 5308.39 | 0.42895279 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.57 | 14.14 | 0.00988807 | 39640.2 | |
| SPLIT TN1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 6728.078 | 6728.078 | 0.380470 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.380470 | 0.44658971 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 6728.08 | 6728.08 | 1.0000 | 0.44658971 | 0.380470 | 20.09 | 14.46 | 0.00821790 | 41047.4 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6728.08 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 6.8217 | 21.10 | 0.00837498 | 21.10 | 0.00837498 | 52.4198 | 806.42 | 0.00 | 6736.92 | 6736.92 | 0.43869833 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.15 | 20.58 | 0.00875166 | 58800.7 | |
| SPLIT TN1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TN1 | T N1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6728.078 | 6728.078 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.380470 | 0.44658971 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 6728.08 | 6728.08 | 1.0000 | 0.44658971 | 0.380470 | 20.09 | 14.46 | 0.00821790 | 41047.4 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6728.08 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 6.8217 | 21.10 | 0.00837498 | 21.10 | 0.00837498 | 52.4198 | 806.42 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TN2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6715.582 | 5373.150 | 0.379698 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.0163 | 1004.8586 | 1.1738 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.379698 | 0.44568445 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | Sensible | 5996.00 | 5842.94 | 0.8928 | 0.44568445 | 0.379698 | 25.96 | 16.53 | 0.00816391 | 46894.0 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 425.303 | 5570.69 | 38.22 | 0.00915158 | 21.18 | 0.02595455 | 6.8356 | 24.05 | 0.00809144 | 24.00 | 0.00809144 | 42.4864 | 4361.75 | 0.00 | 6714.44 | 5298.15 | 0.42808328 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.57 | 14.14 | 0.00988750 | 39637.5 | |
| SPLIT TN2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 6715.582 | 6715.582 | 0.379698 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.379698 | 0.44568445 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 6715.58 | 6715.58 | 1.0000 | 0.44568445 | 0.379698 | 20.09 | 14.46 | 0.00821759 | 41044.5 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6715.58 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 6.8356 | 21.10 | 0.00837499 | 21.10 | 0.00837499 | 52.4199 | 806.40 | 0.00 | 6724.41 | 6724.41 | 0.43780907 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.15 | 20.58 | 0.00875166 | 58803.3 | |
| SPLIT TN2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TN2 | T N2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6715.582 | 6715.582 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.379698 | 0.44568445 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 6715.58 | 6715.58 | 1.0000 | 0.44568445 | 0.379698 | 20.09 | 14.46 | 0.00821759 | 41044.5 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6715.58 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 6.8356 | 21.10 | 0.00837499 | 21.10 | 0.00837499 | 52.4199 | 806.40 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TS1 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6742.384 | 5396.595 | 0.379327 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.0747 | 1004.8586 | 1.1738 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.379327 | 0.44524834 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | Sensible | 6024.78 | 5842.41 | 0.8936 | 0.44524834 | 0.379327 | 25.96 | 16.55 | 0.00819533 | 46974.9 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 424.887 | 5599.89 | 38.22 | 0.00915158 | 21.18 | 0.02595455 | 6.8423 | 24.05 | 0.00812509 | 24.00 | 0.00812509 | 42.6612 | 4357.54 | 0.00 | 6741.24 | 5320.85 | 0.42766440 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.51 | 14.11 | 0.00988247 | 39559.5 | |
| SPLIT TS1 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 6742.384 | 6742.384 | 0.379327 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.379327 | 0.44524834 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 6742.38 | 6742.38 | 1.0000 | 0.44524834 | 0.379327 | 20.09 | 14.12 | 0.00784737 | 40103.4 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6742.38 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 6.8423 | 21.10 | 0.00797774 | 21.10 | 0.00797774 | 49.9661 | 955.04 | 0.00 | 6751.24 | 6751.24 | 0.43738067 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.23 | 20.60 | 0.00875166 | 58879.7 | |
| SPLIT TS1_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TS1 | T S1 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6742.384 | 6742.384 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.379327 | 0.44524834 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 6742.38 | 6742.38 | 1.0000 | 0.44524834 | 0.379327 | 20.09 | 14.12 | 0.00784737 | 40103.4 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6742.38 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 6.8423 | 21.10 | 0.00797774 | 21.10 | 0.00797774 | 49.9661 | 955.04 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
| SPLIT TS2 HP COOLING COIL | Coil:Cooling:DX:SingleSpeed | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 6730.016 | 5386.245 | 0.378557 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.0757 | 1004.8586 | 1.1738 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.378557 | 0.44434470 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 19:00:00 | Sensible | 6013.92 | 5831.42 | 0.8936 | 0.44434470 | 0.378557 | 25.96 | 16.56 | 0.00819587 | 46978.2 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 424.025 | 5589.90 | 38.22 | 0.00915158 | 21.18 | 0.02595455 | 6.8562 | 24.05 | 0.00812552 | 24.00 | 0.00812552 | 42.6634 | 4348.88 | 0.00 | 6728.87 | 5310.65 | 0.42679644 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.51 | 14.11 | 0.00988181 | 39556.4 | |
| SPLIT TS2 HEATING COIL | COIL:HEATING:DX:SINGLESPEED | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | Yes | unknown | No | 6730.016 | 6730.016 | 0.378557 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.378557 | 0.44434470 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 6730.02 | 6730.02 | 1.0000 | 0.44434470 | 0.378557 | 20.09 | 14.12 | 0.00784710 | 40100.6 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6730.02 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 6.8562 | 21.10 | 0.00797774 | 21.10 | 0.00797774 | 49.9661 | 955.02 | 0.00 | 6738.86 | 6738.86 | 0.43649299 | 21.11 | 15.56 | 0.00875166 | 43444.1 | 36.23 | 20.60 | 0.00875166 | 58882.7 | |
| SPLIT TS2_SUPPHEATCOIL | COIL:HEATING:ELECTRIC | AirLoop | AirLoopHVAC | SPLIT TS2 | T S2 APARTMENT | Non-Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 6730.016 | 6730.016 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.378557 | 0.44434470 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 05:00:00 | Sensible | 6730.02 | 6730.02 | 1.0000 | 0.44434470 | 0.378557 | 20.09 | 14.12 | 0.00784710 | 40100.6 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6730.02 | 6.30 | 0.00607234 | 6.30 | 0.02595455 | 6.8562 | 21.10 | 0.00797774 | 21.10 | 0.00797774 | 49.9661 | 955.02 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Economizer| High Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
| None |
| Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
| None |
| Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
| G SW APARTMENT | 4666.17 | 585.33 | 199.00 |
| G NW APARTMENT | 6140.00 | 1500.50 | 214.67 |
| OFFICE | 1507.33 | 57.83 | 11.83 |
| G NE APARTMENT | 6187.67 | 1446.50 | 215.33 |
| G N1 APARTMENT | 6095.83 | 1424.67 | 549.17 |
| G N2 APARTMENT | 6107.50 | 1438.17 | 568.17 |
| G S1 APARTMENT | 4825.17 | 578.33 | 472.00 |
| G S2 APARTMENT | 4911.33 | 307.33 | 189.83 |
| M SW APARTMENT | 4604.83 | 893.83 | 550.83 |
| M NW APARTMENT | 6112.17 | 1889.83 | 702.17 |
| M SE APARTMENT | 4588.50 | 903.33 | 560.33 |
| M NE APARTMENT | 6129.83 | 1842.50 | 709.67 |
| M N1 APARTMENT | 5950.83 | 1826.83 | 1084.17 |
| M N2 APARTMENT | 5961.33 | 1823.50 | 1084.33 |
| M S1 APARTMENT | 4668.17 | 920.17 | 808.33 |
| M S2 APARTMENT | 4669.00 | 920.50 | 809.00 |
| T SW APARTMENT | 4180.83 | 2016.50 | 675.17 |
| T NW APARTMENT | 5887.67 | 3083.50 | 925.00 |
| T SE APARTMENT | 4165.67 | 2032.00 | 690.83 |
| T NE APARTMENT | 5878.17 | 3053.00 | 915.83 |
| T N1 APARTMENT | 5704.00 | 3100.33 | 996.67 |
| T N2 APARTMENT | 5709.83 | 3097.00 | 997.17 |
| T S1 APARTMENT | 4253.33 | 1852.00 | 792.67 |
| T S2 APARTMENT | 4253.50 | 1853.83 | 793.17 |
| T CORRIDOR | 8760.00 | 8760.00 | 8760.00 |
| G CORRIDOR | 7838.50 | 6311.50 | 5742.67 |
| M CORRIDOR | 8760.00 | 8760.00 | 8760.00 |
| Facility | 8760.00 | 8760.00 | 8760.00 |
| During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
| G SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 0.00 | 36.83 | 0.00 | 0.00 |
| G NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
| Facility | 0.00 | 36.83 | 0.00 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Average Outdoor Air During Occupied Hours| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| G SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.359 | 0.013 | 0.000 | 0.032 |
| G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.016 | 0.000 | 0.044 |
| OFFICE | 4.75 | 4.75 | 268.97 | 0.527 | 0.023 | 0.000 | 0.000 |
| G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.016 | 0.000 | 0.045 |
| G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.010 | 0.000 | 0.046 |
| G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.010 | 0.000 | 0.046 |
| G S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.359 | 0.008 | 0.000 | 0.031 |
| G S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.359 | 0.008 | 0.000 | 0.029 |
| M SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.359 | 0.019 | 0.000 | 0.031 |
| M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.023 | 0.000 | 0.046 |
| M SE APARTMENT | 2.41 | 2.50 | 268.97 | 0.359 | 0.019 | 0.000 | 0.031 |
| M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.023 | 0.000 | 0.048 |
| M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.014 | 0.000 | 0.052 |
| M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.014 | 0.000 | 0.052 |
| M S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.360 | 0.011 | 0.000 | 0.030 |
| M S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.360 | 0.011 | 0.000 | 0.030 |
| T SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.359 | 0.025 | 0.000 | 0.033 |
| T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.030 | 0.000 | 0.046 |
| T SE APARTMENT | 2.41 | 2.50 | 268.97 | 0.359 | 0.025 | 0.000 | 0.034 |
| T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.030 | 0.000 | 0.049 |
| T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.018 | 0.000 | 0.050 |
| T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.359 | 0.018 | 0.000 | 0.050 |
| T S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.359 | 0.015 | 0.000 | 0.033 |
| T S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.359 | 0.015 | 0.000 | 0.033 |
| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| G SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.332 | 0.000 | 0.000 | 0.000 |
| G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.329 | 0.000 | 0.000 | 0.000 |
| OFFICE | 4.75 | 4.75 | 268.97 | 0.485 | 0.000 | 0.000 | 0.000 |
| G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.329 | 0.000 | 0.000 | 0.000 |
| G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.330 | 0.000 | 0.000 | 0.000 |
| G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.330 | 0.000 | 0.000 | 0.000 |
| G S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.332 | 0.000 | 0.000 | 0.000 |
| G S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.332 | 0.000 | 0.000 | 0.000 |
| M SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.331 | 0.000 | 0.000 | 0.000 |
| M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.329 | 0.000 | 0.000 | 0.000 |
| M SE APARTMENT | 2.41 | 2.50 | 268.97 | 0.331 | 0.000 | 0.000 | 0.000 |
| M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.329 | 0.000 | 0.000 | 0.000 |
| M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.330 | 0.000 | 0.000 | 0.000 |
| M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.330 | 0.000 | 0.000 | 0.000 |
| M S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.332 | 0.000 | 0.000 | 0.000 |
| M S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.332 | 0.000 | 0.000 | 0.000 |
| T SW APARTMENT | 2.41 | 2.50 | 268.97 | 0.329 | 0.000 | 0.000 | 0.000 |
| T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.326 | 0.000 | 0.000 | 0.000 |
| T SE APARTMENT | 2.41 | 2.50 | 268.97 | 0.329 | 0.000 | 0.000 | 0.000 |
| T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.327 | 0.000 | 0.000 | 0.000 |
| T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.327 | 0.000 | 0.000 | 0.000 |
| T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.327 | 0.000 | 0.000 | 0.000 |
| T S1 APARTMENT | 2.41 | 2.50 | 268.97 | 0.329 | 0.000 | 0.000 | 0.000 |
| T S2 APARTMENT | 2.41 | 2.50 | 268.97 | 0.329 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Mechanical Ventilation Parameters by Zone| AirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
| G SW APARTMENT | SPLIT GSW | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G NW APARTMENT | SPLIT GNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| OFFICE | SPLIT OFFICE | 4.75 | 4.75 | 268.97 | 88.25 | 0.0381 | 0.038 |
| G NE APARTMENT | SPLIT GNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G N1 APARTMENT | SPLIT GN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G N2 APARTMENT | SPLIT GN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G S1 APARTMENT | SPLIT GS1 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| G S2 APARTMENT | SPLIT GS2 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| M SW APARTMENT | SPLIT MSW | 2.41 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M NW APARTMENT | SPLIT MNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M SE APARTMENT | SPLIT MSE | 2.41 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M NE APARTMENT | SPLIT MNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M N1 APARTMENT | SPLIT MN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M N2 APARTMENT | SPLIT MN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M S1 APARTMENT | SPLIT MS1 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| M S2 APARTMENT | SPLIT MS2 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0519 | 0.052 |
| T SW APARTMENT | SPLIT TSW | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T NW APARTMENT | SPLIT TNW | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T SE APARTMENT | SPLIT TSE | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T NE APARTMENT | SPLIT TNE | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T N1 APARTMENT | SPLIT TN1 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T N2 APARTMENT | SPLIT TN2 | 1.71 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T S1 APARTMENT | SPLIT TS1 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| T S2 APARTMENT | SPLIT TS2 | 2.41 | 2.50 | 268.97 | 88.25 | 0.0260 | 0.026 |
| Total Facility | 68.20 | 82.25 | 8607.06 | 2823.98 | 0.8427 | 1.258 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| G SW APARTMENT | 818502.78 | 89633.63 | 908136.41 | 36336.51 | 944472.92 | 818502.78 | 0.00 | 7733.97 | 1026.03 | 2615.00 |
| G NW APARTMENT | 818502.78 | 101981.51 | 920484.29 | 36336.51 | 956820.80 | 818502.78 | 0.00 | 7505.42 | 1254.58 | 0.00 |
| OFFICE | 1166912.23 | 0.00 | 1166912.23 | 36336.51 | 1203248.74 | 1201711.97 | 500.00 | 8260.00 | 0.00 | 7010.00 |
| G NE APARTMENT | 818502.78 | 103376.99 | 921879.77 | 36336.51 | 958216.28 | 818502.78 | 0.00 | 7509.85 | 1250.15 | 0.00 |
| G N1 APARTMENT | 818502.78 | 106682.49 | 925185.27 | 21917.26 | 947102.53 | 818502.78 | 0.00 | 7464.24 | 1295.76 | 0.00 |
| G N2 APARTMENT | 818502.78 | 106680.41 | 925183.18 | 21917.26 | 947100.45 | 818502.78 | 0.00 | 7465.32 | 1294.68 | 0.00 |
| G S1 APARTMENT | 818502.78 | 84909.24 | 903412.02 | 21917.26 | 925329.28 | 818502.78 | 0.00 | 7793.77 | 966.23 | 2615.00 |
| G S2 APARTMENT | 818502.78 | 81966.81 | 900469.59 | 21917.26 | 922386.85 | 818502.78 | 0.00 | 7836.19 | 923.81 | 2615.00 |
| M SW APARTMENT | 1637005.55 | 89467.66 | 1726473.22 | 52218.20 | 1778691.42 | 1637005.55 | 0.00 | 7773.71 | 986.29 | 2615.00 |
| M NW APARTMENT | 1637005.55 | 106735.40 | 1743740.95 | 52218.20 | 1795959.16 | 1637005.55 | 0.00 | 7512.00 | 1248.00 | 0.00 |
| M SE APARTMENT | 1637005.55 | 85344.13 | 1722349.68 | 52218.20 | 1774567.89 | 1637005.55 | 0.00 | 7830.75 | 929.25 | 2615.00 |
| M NE APARTMENT | 1637005.55 | 110428.11 | 1747433.67 | 52218.20 | 1799651.87 | 1637005.55 | 0.00 | 7490.28 | 1269.72 | 0.00 |
| M N1 APARTMENT | 1637005.55 | 119289.36 | 1756294.91 | 31496.70 | 1787791.61 | 1637005.55 | 0.00 | 7384.31 | 1375.69 | 0.00 |
| M N2 APARTMENT | 1637005.55 | 119164.36 | 1756169.91 | 31496.70 | 1787666.61 | 1637005.55 | 0.00 | 7386.77 | 1373.23 | 0.00 |
| M S1 APARTMENT | 1637005.55 | 84663.61 | 1721669.16 | 31496.70 | 1753165.86 | 1637005.55 | 0.00 | 7830.53 | 929.47 | 2615.00 |
| M S2 APARTMENT | 1637005.55 | 84482.55 | 1721488.10 | 31496.70 | 1752984.80 | 1637005.55 | 0.00 | 7832.68 | 927.32 | 2615.00 |
| T SW APARTMENT | 818502.78 | 97476.89 | 915979.67 | 69073.52 | 985053.19 | 818502.78 | 0.00 | 7690.65 | 1069.35 | 2615.00 |
| T NW APARTMENT | 818502.78 | 105444.18 | 923946.96 | 69073.52 | 993020.48 | 818502.78 | 0.00 | 7518.00 | 1242.00 | 0.00 |
| T SE APARTMENT | 818502.78 | 96126.02 | 914628.80 | 69073.52 | 983702.32 | 818502.78 | 0.00 | 7726.85 | 1033.15 | 2615.00 |
| T NE APARTMENT | 818502.78 | 112168.28 | 930671.06 | 69073.52 | 999744.58 | 818502.78 | 0.00 | 7461.56 | 1298.44 | 0.00 |
| T N1 APARTMENT | 818502.78 | 115730.72 | 934233.50 | 41663.39 | 975896.89 | 818502.78 | 0.00 | 7409.94 | 1350.06 | 0.00 |
| T N2 APARTMENT | 818502.78 | 115647.83 | 934150.61 | 41663.39 | 975814.00 | 818502.78 | 0.00 | 7412.17 | 1347.83 | 0.00 |
| T S1 APARTMENT | 818502.78 | 97500.73 | 916003.51 | 41663.39 | 957666.90 | 818502.78 | 0.00 | 7711.89 | 1048.11 | 2615.00 |
| T S2 APARTMENT | 818502.78 | 97183.91 | 915686.69 | 41663.39 | 957350.09 | 818502.78 | 0.00 | 7715.77 | 1044.23 | 2615.00 |
| Total Facility | 39636542.76 | 3111660.00 | 42748202.76 | 1345681.97 | 44093884.73 | 39671342.50 | 500.00 | 8719.46 | 1453.32 | 8760.00 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
| G SW APARTMENT | 0.0260 | 0.0023 | 0.0282 | 0.0009 | 0.0292 | 0.0260 | 0.00 | 5562.95 | 582.05 |
| G NW APARTMENT | 0.0260 | 0.0032 | 0.0292 | 0.0012 | 0.0303 | 0.0260 | 0.00 | 7505.42 | 1254.58 |
| OFFICE | 0.0381 | 0.0000 | 0.0381 | 0.0016 | 0.0397 | 0.0381 | 0.00 | 1750.00 | 0.00 |
| G NE APARTMENT | 0.0260 | 0.0033 | 0.0292 | 0.0012 | 0.0304 | 0.0260 | 0.00 | 7509.85 | 1250.15 |
| G N1 APARTMENT | 0.0260 | 0.0034 | 0.0293 | 0.0007 | 0.0300 | 0.0260 | 0.00 | 7464.24 | 1295.76 |
| G N2 APARTMENT | 0.0260 | 0.0034 | 0.0293 | 0.0007 | 0.0300 | 0.0260 | 0.00 | 7465.32 | 1294.68 |
| G S1 APARTMENT | 0.0260 | 0.0022 | 0.0282 | 0.0006 | 0.0287 | 0.0260 | 0.00 | 5582.00 | 563.00 |
| G S2 APARTMENT | 0.0260 | 0.0021 | 0.0281 | 0.0006 | 0.0286 | 0.0260 | 0.00 | 5612.51 | 532.49 |
| M SW APARTMENT | 0.0519 | 0.0022 | 0.0542 | 0.0013 | 0.0555 | 0.0519 | 0.00 | 5585.79 | 559.21 |
| M NW APARTMENT | 0.0519 | 0.0034 | 0.0553 | 0.0017 | 0.0569 | 0.0519 | 0.00 | 7512.00 | 1248.00 |
| M SE APARTMENT | 0.0519 | 0.0022 | 0.0541 | 0.0013 | 0.0555 | 0.0519 | 0.00 | 5591.33 | 553.67 |
| M NE APARTMENT | 0.0519 | 0.0035 | 0.0554 | 0.0017 | 0.0571 | 0.0519 | 0.00 | 7490.28 | 1269.72 |
| M N1 APARTMENT | 0.0519 | 0.0038 | 0.0557 | 0.0010 | 0.0567 | 0.0519 | 0.00 | 7384.31 | 1375.69 |
| M N2 APARTMENT | 0.0519 | 0.0038 | 0.0557 | 0.0010 | 0.0567 | 0.0519 | 0.00 | 7386.77 | 1373.23 |
| M S1 APARTMENT | 0.0519 | 0.0022 | 0.0541 | 0.0008 | 0.0549 | 0.0519 | 0.00 | 5603.38 | 541.62 |
| M S2 APARTMENT | 0.0519 | 0.0022 | 0.0541 | 0.0008 | 0.0549 | 0.0519 | 0.00 | 5604.02 | 540.98 |
| T SW APARTMENT | 0.0260 | 0.0024 | 0.0284 | 0.0018 | 0.0301 | 0.0260 | 0.00 | 5544.51 | 600.49 |
| T NW APARTMENT | 0.0260 | 0.0033 | 0.0293 | 0.0022 | 0.0315 | 0.0260 | 0.00 | 7518.00 | 1242.00 |
| T SE APARTMENT | 0.0260 | 0.0025 | 0.0284 | 0.0018 | 0.0302 | 0.0260 | 0.00 | 5542.55 | 602.45 |
| T NE APARTMENT | 0.0260 | 0.0036 | 0.0295 | 0.0022 | 0.0317 | 0.0260 | 0.00 | 7461.56 | 1298.44 |
| T N1 APARTMENT | 0.0260 | 0.0037 | 0.0296 | 0.0013 | 0.0309 | 0.0260 | 0.00 | 7409.94 | 1350.06 |
| T N2 APARTMENT | 0.0260 | 0.0037 | 0.0296 | 0.0013 | 0.0309 | 0.0260 | 0.00 | 7412.17 | 1347.83 |
| T S1 APARTMENT | 0.0260 | 0.0024 | 0.0284 | 0.0011 | 0.0295 | 0.0260 | 0.00 | 5549.84 | 595.16 |
| T S2 APARTMENT | 0.0260 | 0.0024 | 0.0284 | 0.0011 | 0.0295 | 0.0260 | 0.00 | 5550.59 | 594.41 |
| Total Facility | 1.2580 | 0.0904 | 1.3484 | 0.0393 | 1.3877 | 1.2580 | 500.00 | 8719.46 | 1453.32 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| SPLIT GSW | 0.00 | 89633.63 | 89633.63 | 818502.78 | 8277.33 | 37.69 | 444.98 | 443.97 |
| SPLIT GNW | 0.00 | 101981.51 | 101981.51 | 818502.78 | 8358.69 | 45.14 | 356.17 | 0.00 |
| SPLIT OFFICE | 1607739.35 | 0.00 | 1607739.35 | 1201711.97 | 448.33 | 9.67 | 8302.00 | 7010.00 |
| SPLIT GNE | 0.00 | 103376.99 | 103376.99 | 818502.78 | 8332.56 | 50.01 | 377.42 | 0.00 |
| SPLIT GN1 | 0.00 | 106682.49 | 106682.49 | 818502.78 | 8312.37 | 49.38 | 398.26 | 0.00 |
| SPLIT GN2 | 0.00 | 106680.41 | 106680.41 | 818502.78 | 8311.36 | 49.50 | 399.14 | 0.00 |
| SPLIT GS1 | 0.00 | 84909.24 | 84909.24 | 818502.78 | 8280.03 | 34.65 | 445.32 | 403.24 |
| SPLIT GS2 | 0.00 | 81966.81 | 81966.81 | 818502.78 | 8281.00 | 34.29 | 444.71 | 391.33 |
| SPLIT MSW | 0.00 | 89467.66 | 89467.66 | 1637005.55 | 8758.83 | 1.00 | 0.17 | 427.09 |
| SPLIT MNW | 0.00 | 106735.40 | 106735.40 | 1637005.55 | 8759.33 | 0.67 | 0.00 | 0.00 |
| SPLIT MSE | 0.00 | 85344.13 | 85344.13 | 1637005.55 | 8758.83 | 1.00 | 0.17 | 375.58 |
| SPLIT MNE | 0.00 | 110428.11 | 110428.11 | 1637005.55 | 8759.33 | 0.67 | 0.00 | 0.00 |
| SPLIT MN1 | 0.00 | 119289.36 | 119289.36 | 1637005.55 | 8759.00 | 0.83 | 0.17 | 0.00 |
| SPLIT MN2 | 0.00 | 119164.36 | 119164.36 | 1637005.55 | 8759.00 | 0.83 | 0.17 | 0.00 |
| SPLIT MS1 | 0.00 | 84663.61 | 84663.61 | 1637005.55 | 8758.67 | 0.83 | 0.50 | 387.85 |
| SPLIT MS2 | 0.00 | 84482.55 | 84482.55 | 1637005.55 | 8758.67 | 0.83 | 0.50 | 386.34 |
| SPLIT TSW | 0.00 | 97476.89 | 97476.89 | 818502.78 | 8249.25 | 36.21 | 474.54 | 468.86 |
| SPLIT TNW | 0.00 | 105444.18 | 105444.18 | 818502.78 | 8289.13 | 37.72 | 433.16 | 0.00 |
| SPLIT TSE | 0.00 | 96126.02 | 96126.02 | 818502.78 | 8222.98 | 36.49 | 500.53 | 430.70 |
| SPLIT TNE | 0.00 | 112168.28 | 112168.28 | 818502.78 | 8256.75 | 43.40 | 459.85 | 0.00 |
| SPLIT TN1 | 0.00 | 115730.72 | 115730.72 | 818502.78 | 8232.53 | 48.89 | 478.58 | 0.00 |
| SPLIT TN2 | 0.00 | 115647.83 | 115647.83 | 818502.78 | 8232.69 | 46.50 | 480.81 | 0.00 |
| SPLIT TS1 | 0.00 | 97500.73 | 97500.73 | 818502.78 | 8213.85 | 36.26 | 509.89 | 452.95 |
| SPLIT TS2 | 0.00 | 97183.91 | 97183.91 | 818502.78 | 8214.75 | 35.80 | 509.45 | 449.81 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
| SPLIT GSW | 0.0000 | 0.0023 | 0.0023 | 0.0260 | 5867.72 | 21.43 | 255.85 |
| SPLIT GNW | 0.0000 | 0.0032 | 0.0032 | 0.0260 | 8358.69 | 45.14 | 356.17 |
| SPLIT OFFICE | 0.0525 | 0.0000 | 0.0525 | 0.0381 | 0.00 | 0.00 | 1750.00 |
| SPLIT GNE | 0.0000 | 0.0033 | 0.0033 | 0.0260 | 8332.56 | 50.01 | 377.42 |
| SPLIT GN1 | 0.0000 | 0.0034 | 0.0034 | 0.0260 | 8312.37 | 49.38 | 398.26 |
| SPLIT GN2 | 0.0000 | 0.0034 | 0.0034 | 0.0260 | 8311.36 | 49.50 | 399.14 |
| SPLIT GS1 | 0.0000 | 0.0022 | 0.0022 | 0.0260 | 5866.32 | 20.75 | 257.93 |
| SPLIT GS2 | 0.0000 | 0.0021 | 0.0021 | 0.0260 | 5867.18 | 20.13 | 257.68 |
| SPLIT MSW | 0.0000 | 0.0022 | 0.0022 | 0.0519 | 6144.83 | 0.17 | 0.00 |
| SPLIT MNW | 0.0000 | 0.0034 | 0.0034 | 0.0519 | 8759.33 | 0.67 | 0.00 |
| SPLIT MSE | 0.0000 | 0.0022 | 0.0022 | 0.0519 | 6144.83 | 0.17 | 0.00 |
| SPLIT MNE | 0.0000 | 0.0035 | 0.0035 | 0.0519 | 8759.33 | 0.67 | 0.00 |
| SPLIT MN1 | 0.0000 | 0.0038 | 0.0038 | 0.0519 | 8759.00 | 0.83 | 0.17 |
| SPLIT MN2 | 0.0000 | 0.0038 | 0.0038 | 0.0519 | 8759.00 | 0.83 | 0.17 |
| SPLIT MS1 | 0.0000 | 0.0022 | 0.0022 | 0.0519 | 6144.83 | 0.17 | 0.00 |
| SPLIT MS2 | 0.0000 | 0.0022 | 0.0022 | 0.0519 | 6144.83 | 0.17 | 0.00 |
| SPLIT TSW | 0.0000 | 0.0024 | 0.0024 | 0.0260 | 5861.12 | 21.92 | 261.96 |
| SPLIT TNW | 0.0000 | 0.0033 | 0.0033 | 0.0260 | 8289.13 | 37.72 | 433.16 |
| SPLIT TSE | 0.0000 | 0.0025 | 0.0025 | 0.0260 | 5847.39 | 20.53 | 277.08 |
| SPLIT TNE | 0.0000 | 0.0036 | 0.0036 | 0.0260 | 8256.75 | 43.40 | 459.85 |
| SPLIT TN1 | 0.0000 | 0.0037 | 0.0037 | 0.0260 | 8232.53 | 48.89 | 478.58 |
| SPLIT TN2 | 0.0000 | 0.0037 | 0.0037 | 0.0260 | 8232.69 | 46.50 | 480.81 |
| SPLIT TS1 | 0.0000 | 0.0024 | 0.0024 | 0.0260 | 5844.96 | 19.71 | 280.33 |
| SPLIT TS2 | 0.0000 | 0.0024 | 0.0024 | 0.0260 | 5845.09 | 19.95 | 279.97 |
| No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
| SPLIT GSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT OFFICE | 500.00 | 8260.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT GS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MSE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT MS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TSW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TNW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TSE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TNE | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TN1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TN2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TS1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| SPLIT TS2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
| SPLIT GSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT OFFICE | 0.0000 | 0.0525 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT GS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MSE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT MS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TSW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TNW | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TSE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TNE | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TN1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TN2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TS1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
| SPLIT TS2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Surfaces by Class| Total | Outdoors | |
| Wall | 126 | 42 |
| Floor | 27 | 9 |
| Roof | 27 | 9 |
| Internal Mass | 24 | 0 |
| Building Detached Shading | 0 | 0 |
| Fixed Detached Shading | 0 | 0 |
| Window | 39 | 39 |
| Door | 0 | 0 |
| Glass Door | 0 | 0 |
| Shading | 0 | 0 |
| Overhang | 0 | 0 |
| Fin | 0 | 0 |
| Tubular Daylighting Device Dome | 0 | 0 |
| Tubular Daylighting Device Diffuser | 0 | 0 |
| Count | |
| HVAC Air Loops | 24 |
| Conditioned Zones | 24 |
| Unconditioned Zones | 3 |
| Supply Plenums | 0 |
| Return Plenums | 0 |
| Count | |
| IDF Objects | 1588 |
| Defaulted Fields | 1666 |
| Fields with Defaults | 5801 |
| Autosized Fields | 648 |
| Autosizable Fields | 770 |
| Autocalculated Fields | 332 |
| Autocalculatable Fields | 509 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Annual and Peak Values - Electricity| Electricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| Electricity:Facility | 1049.47 | 14366.67 | 17-JAN-03:50 | 66687.50 | 10-JUN-16:50 |
| Electricity:Building | 527.01 | 10157.12 | 01-JAN-03:10 | 25266.90 | 03-JAN-17:10 |
| Electricity:Zone:G SW APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| Electricity:SpaceType:GENERAL | 527.01 | 10157.12 | 01-JAN-03:10 | 25266.90 | 03-JAN-17:10 |
| InteriorLights:Electricity | 73.00 | 1491.31 | 01-JAN-00:10 | 4040.47 | 01-JAN-19:10 |
| InteriorLights:Electricity:Zone:G SW APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| InteriorLights:Electricity:SpaceType:GENERAL | 73.00 | 1491.31 | 01-JAN-00:10 | 4040.47 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity | 67.97 | 1461.31 | 01-JAN-00:10 | 3560.62 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G SW APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 67.97 | 1461.31 | 01-JAN-00:10 | 3560.62 | 01-JAN-19:10 |
| Electricity:Zone:G NW APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G NW APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G NW APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:OFFICE | 13.20 | 218.21 | 01-JAN-00:10 | 992.54 | 03-JAN-08:10 |
| InteriorLights:Electricity:Zone:OFFICE | 5.68 | 89.52 | 01-JAN-00:10 | 447.62 | 03-JAN-08:10 |
| LightsWired:InteriorLights:Electricity:Zone:OFFICE | 5.68 | 89.52 | 01-JAN-00:10 | 447.62 | 03-JAN-08:10 |
| Electricity:Zone:G NE APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G NE APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G NE APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:G N1 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G N1 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G N1 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:G N2 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G N2 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G N2 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:G S1 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G S1 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G S1 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:G S2 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:G S2 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:G S2 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:M SW APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M SW APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M SW APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:M NW APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M NW APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M NW APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:M SE APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M SE APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M SE APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:M NE APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M NE APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M NE APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:M N1 APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M N1 APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M N1 APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:M N2 APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M N2 APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M N2 APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:M S1 APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M S1 APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M S1 APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:M S2 APARTMENT | 26.26 | 458.32 | 01-JAN-03:10 | 1325.26 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:M S2 APARTMENT | 1.84 | 10.97 | 01-JAN-00:10 | 175.43 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:M S2 APARTMENT | 1.51 | 9.03 | 01-JAN-00:10 | 144.47 | 01-JAN-19:10 |
| Electricity:Zone:T SW APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T SW APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T SW APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:T NW APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T NW APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T NW APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:T SE APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T SE APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T SE APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:T NE APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T NE APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T NE APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:T N1 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T N1 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T N1 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:T N2 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T N2 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T N2 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:T S1 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T S1 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T S1 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:T S2 APARTMENT | 13.13 | 229.16 | 01-JAN-03:10 | 662.63 | 01-JAN-18:10 |
| InteriorLights:Electricity:Zone:T S2 APARTMENT | 0.92 | 5.48 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 |
| LightsWired:InteriorLights:Electricity:Zone:T S2 APARTMENT | 0.76 | 4.52 | 01-JAN-00:10 | 72.24 | 01-JAN-19:10 |
| Electricity:Zone:G CORRIDOR | 77.61 | 1911.10 | 01-JAN-00:10 | 4111.81 | 01-JAN-07:10 |
| InteriorLights:Electricity:Zone:G CORRIDOR | 9.71 | 307.95 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:G CORRIDOR | 9.71 | 307.95 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 |
| Electricity:Zone:M CORRIDOR | 19.42 | 615.89 | 01-JAN-00:10 | 615.89 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:M CORRIDOR | 19.42 | 615.89 | 01-JAN-00:10 | 615.89 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:M CORRIDOR | 19.42 | 615.89 | 01-JAN-00:10 | 615.89 | 01-JAN-00:10 |
| Electricity:Zone:T CORRIDOR | 9.71 | 307.95 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 |
| InteriorLights:Electricity:Zone:T CORRIDOR | 9.71 | 307.95 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 |
| LightsWired:InteriorLights:Electricity:Zone:T CORRIDOR | 9.71 | 307.95 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 |
| LightsPlugIn:InteriorLights:Electricity | 5.02 | 30.00 | 01-JAN-00:10 | 479.85 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G SW APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:SpaceType:GENERAL | 5.02 | 30.00 | 01-JAN-00:10 | 479.85 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G NW APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G NE APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G N1 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G N2 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G S1 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:G S2 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M SW APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M NW APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M SE APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M NE APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M N1 APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M N2 APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M S1 APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:M S2 APARTMENT | 0.32 | 1.94 | 01-JAN-00:10 | 30.96 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T SW APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T NW APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T SE APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T NE APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T N1 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T N2 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T S1 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| LightsPlugIn:InteriorLights:Electricity:Zone:T S2 APARTMENT | 0.16 | 0.97 | 01-JAN-00:10 | 15.48 | 01-JAN-19:10 |
| InteriorEquipment:Electricity | 454.01 | 8665.81 | 01-JAN-03:10 | 22246.15 | 03-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G CORRIDOR | 67.90 | 1603.15 | 01-JAN-00:10 | 3803.87 | 01-JAN-07:10 |
| InteriorEquipment:Electricity:SpaceType:GENERAL | 454.01 | 8665.81 | 01-JAN-03:10 | 22246.15 | 03-JAN-17:10 |
| ElevatorLift:InteriorEquipment:Electricity | 67.41 | 1600.00 | 01-JAN-00:10 | 3772.37 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity:Zone:G CORRIDOR | 67.41 | 1600.00 | 01-JAN-00:10 | 3772.37 | 01-JAN-07:10 |
| ElevatorLift:InteriorEquipment:Electricity:SpaceType:GENERAL | 67.41 | 1600.00 | 01-JAN-00:10 | 3772.37 | 01-JAN-07:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity | 0.49 | 3.15 | 01-JAN-00:10 | 31.50 | 01-JAN-07:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity:Zone:G CORRIDOR | 0.49 | 3.15 | 01-JAN-00:10 | 31.50 | 01-JAN-07:10 |
| ElevatorLightsFan:InteriorEquipment:Electricity:SpaceType:GENERAL | 0.49 | 3.15 | 01-JAN-00:10 | 31.50 | 01-JAN-07:10 |
| InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity | 386.12 | 7062.66 | 01-JAN-03:10 | 18442.28 | 03-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 386.12 | 7062.66 | 01-JAN-03:10 | 18442.28 | 03-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:OFFICE | 7.52 | 128.69 | 01-JAN-00:10 | 544.92 | 03-JAN-08:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:OFFICE | 7.52 | 128.69 | 01-JAN-00:10 | 544.92 | 03-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:10 | 1177.25 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| MiscPlug:InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:10 | 588.62 | 01-JAN-17:10 |
| Fans:Electricity | 144.96 | 1462.22 | 03-JAN-12:10 | 9389.71 | 07-JUN-16:20 |
| Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Ventilation (simple):Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityPurchased:Facility | 1049.47 | 14366.67 | 17-JAN-03:50 | 66687.50 | 10-JUN-16:50 |
| ElectricityPurchased:Plant | 1049.47 | 14366.67 | 17-JAN-03:50 | 66687.50 | 10-JUN-16:50 |
| Cogeneration:ElectricityPurchased | 1049.47 | 14366.67 | 17-JAN-03:50 | 66687.50 | 10-JUN-16:50 |
| General:Cogeneration:ElectricityPurchased | 1049.47 | 14366.67 | 17-JAN-03:50 | 66687.50 | 10-JUN-16:50 |
| ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityNet:Facility | 1049.47 | 14366.67 | 17-JAN-03:50 | 66687.50 | 10-JUN-16:50 |
| ElectricityNet:Plant | 1049.47 | 14366.67 | 17-JAN-03:50 | 66687.50 | 10-JUN-16:50 |
| Cogeneration:ElectricityNet | 1049.47 | 14366.67 | 17-JAN-03:50 | 66687.50 | 10-JUN-16:50 |
| General:Cogeneration:ElectricityNet | 1049.47 | 14366.67 | 17-JAN-03:50 | 66687.50 | 10-JUN-16:50 |
| Electricity:HVAC | 488.97 | 1550.93 | 03-JAN-12:10 | 41472.40 | 10-JUN-16:50 |
| HeatRecovery:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:HeatRecovery:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Fans:Electricity | 144.96 | 1462.22 | 03-JAN-12:10 | 9389.71 | 07-JUN-16:20 |
| Cooling:Electricity | 343.35 | 0.00 | 01-JAN-00:10 | 32110.08 | 10-JUN-16:50 |
| General:Cooling:Electricity | 343.35 | 0.00 | 01-JAN-00:10 | 32110.08 | 10-JUN-16:50 |
| Heating:Electricity | 0.67 | 0.00 | 01-JAN-12:10 | 1649.55 | 02-JAN-06:00 |
| General:Heating:Electricity | 0.67 | 0.00 | 01-JAN-12:10 | 1649.55 | 02-JAN-06:00 |
| ExteriorLights:Electricity | 33.03 | 0.00 | 01-JAN-07:20 | 2101.03 | 01-JAN-00:10 |
| General:ExteriorLights:Electricity | 33.03 | 0.00 | 01-JAN-07:20 | 2101.03 | 01-JAN-00:10 |
| Electricity:Plant | 0.46 | 14.49 | 01-JAN-00:10 | 14.49 | 01-JAN-07:10 |
| Pumps:Electricity | 0.46 | 14.49 | 01-JAN-00:10 | 14.49 | 01-JAN-07:10 |
| General:Pumps:Electricity | 0.46 | 14.49 | 01-JAN-00:10 | 14.49 | 01-JAN-07:10 |
| Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| NaturalGas:Facility | 324.48 | 0.00 | 01-JAN-03:10 | 23788.17 | 21-JAN-08:00 |
| NaturalGas:Plant | 324.48 | 0.00 | 01-JAN-03:10 | 23788.17 | 21-JAN-08:00 |
| WaterSystems:NaturalGas | 324.48 | 0.00 | 01-JAN-03:10 | 23788.17 | 21-JAN-08:00 |
| Water Heater:WaterSystems:NaturalGas | 324.48 | 0.00 | 01-JAN-03:10 | 23788.17 | 21-JAN-08:00 |
| Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| Water:Facility | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 04-MAR-07:10 |
| Water:Plant | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 04-MAR-07:10 |
| WaterSystems:Water | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 04-MAR-07:10 |
| WaterUse:WaterSystems:Water | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 04-MAR-07:10 |
| MainsWater:Facility | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 04-MAR-07:10 |
| MainsWater:Plant | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 04-MAR-07:10 |
| WaterSystems:MainsWater | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 04-MAR-07:10 |
| WaterUse:WaterSystems:MainsWater | 1875.51 | 0.00 | 01-JAN-02:10 | 0.00 | 04-MAR-07:10 |
| Water Heater:WaterSystems:Water | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Water Heater:WaterSystems:MainsWater | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
| Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| EnergyTransfer:Facility | 2637.07 | 8547.69 | 14-OCT-21:10 | 198357.32 | 02-JUL-17:10 |
| EnergyTransfer:Building | 912.91 | 128.98 | 09-OCT-21:30 | 77103.97 | 06-JUN-16:00 |
| EnergyTransfer:Zone:G SW APARTMENT | 33.11 | 0.01 | 07-APR-08:20 | 2783.22 | 01-OCT-16:10 |
| Heating:EnergyTransfer | 5.71 | 0.00 | 01-JAN-19:00 | 4324.98 | 02-JAN-06:00 |
| Heating:EnergyTransfer:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 50.01 | 11-APR-09:40 |
| General:Heating:EnergyTransfer | 5.71 | 0.00 | 01-JAN-19:00 | 4324.98 | 02-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 50.01 | 11-APR-09:40 |
| Cooling:EnergyTransfer | 907.20 | 0.00 | 11-MAR-06:20 | 77103.97 | 06-JUN-16:00 |
| Cooling:EnergyTransfer:Zone:G SW APARTMENT | 33.11 | 0.00 | 25-JAN-13:20 | 2783.22 | 01-OCT-16:10 |
| General:Cooling:EnergyTransfer | 907.20 | 0.00 | 11-MAR-06:20 | 77103.97 | 06-JUN-16:00 |
| General:Cooling:EnergyTransfer:Zone:G SW APARTMENT | 33.11 | 0.00 | 25-JAN-13:20 | 2783.22 | 01-OCT-16:10 |
| EnergyTransfer:Zone:G NW APARTMENT | 27.99 | 0.02 | 30-MAR-08:30 | 2807.91 | 07-JUN-17:10 |
| Heating:EnergyTransfer:Zone:G NW APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 58.66 | 04-NOV-11:10 |
| General:Heating:EnergyTransfer:Zone:G NW APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 58.66 | 04-NOV-11:10 |
| Cooling:EnergyTransfer:Zone:G NW APARTMENT | 27.99 | 0.00 | 04-JAN-13:10 | 2807.91 | 07-JUN-17:10 |
| General:Cooling:EnergyTransfer:Zone:G NW APARTMENT | 27.99 | 0.00 | 04-JAN-13:10 | 2807.91 | 07-JUN-17:10 |
| EnergyTransfer:Zone:OFFICE | 28.42 | 0.00 | 26-FEB-23:40 | 4876.62 | 12-JUN-06:20 |
| Heating:EnergyTransfer:Zone:OFFICE | 3.96 | 0.00 | 01-JAN-00:10 | 1031.14 | 07-JUN-17:10 |
| General:Heating:EnergyTransfer:Zone:OFFICE | 3.96 | 0.00 | 01-JAN-00:10 | 1031.14 | 07-JUN-17:10 |
| Cooling:EnergyTransfer:Zone:OFFICE | 24.46 | 0.00 | 01-JAN-11:50 | 4876.62 | 12-JUN-06:20 |
| General:Cooling:EnergyTransfer:Zone:OFFICE | 24.46 | 0.00 | 01-JAN-11:50 | 4876.62 | 12-JUN-06:20 |
| EnergyTransfer:Zone:G NE APARTMENT | 27.99 | 0.03 | 21-MAR-15:20 | 2468.97 | 12-JUN-17:20 |
| Heating:EnergyTransfer:Zone:G NE APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 45.43 | 05-MAR-11:30 |
| General:Heating:EnergyTransfer:Zone:G NE APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 45.43 | 05-MAR-11:30 |
| Cooling:EnergyTransfer:Zone:G NE APARTMENT | 27.98 | 0.00 | 04-JAN-13:20 | 2468.97 | 12-JUN-17:20 |
| General:Cooling:EnergyTransfer:Zone:G NE APARTMENT | 27.98 | 0.00 | 04-JAN-13:20 | 2468.97 | 12-JUN-17:20 |
| EnergyTransfer:Zone:G N1 APARTMENT | 23.36 | 0.02 | 24-NOV-16:40 | 1915.29 | 12-JUN-17:30 |
| Heating:EnergyTransfer:Zone:G N1 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 59.41 | 04-NOV-11:10 |
| General:Heating:EnergyTransfer:Zone:G N1 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 59.41 | 04-NOV-11:10 |
| Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 23.36 | 0.00 | 04-JAN-13:40 | 1915.29 | 12-JUN-17:30 |
| General:Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 23.36 | 0.00 | 04-JAN-13:40 | 1915.29 | 12-JUN-17:30 |
| EnergyTransfer:Zone:G N2 APARTMENT | 23.38 | 0.01 | 09-MAR-21:10 | 1910.36 | 12-JUN-17:30 |
| Heating:EnergyTransfer:Zone:G N2 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 59.35 | 04-NOV-11:10 |
| General:Heating:EnergyTransfer:Zone:G N2 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 59.35 | 04-NOV-11:10 |
| Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 23.37 | 0.00 | 04-JAN-13:40 | 1910.36 | 12-JUN-17:30 |
| General:Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 23.37 | 0.00 | 04-JAN-13:40 | 1910.36 | 12-JUN-17:30 |
| EnergyTransfer:Zone:G S1 APARTMENT | 29.14 | 0.02 | 30-MAR-08:40 | 2494.88 | 02-DEC-14:30 |
| Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 50.32 | 11-APR-09:40 |
| General:Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 50.32 | 11-APR-09:40 |
| Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 29.13 | 0.00 | 25-JAN-13:20 | 2494.88 | 02-DEC-14:30 |
| General:Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 29.13 | 0.00 | 25-JAN-13:20 | 2494.88 | 02-DEC-14:30 |
| EnergyTransfer:Zone:G S2 APARTMENT | 31.36 | 0.05 | 23-MAR-22:10 | 2561.09 | 25-NOV-14:50 |
| Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 49.93 | 11-APR-09:40 |
| General:Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 49.93 | 11-APR-09:40 |
| Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 31.36 | 0.00 | 25-JAN-13:20 | 2561.09 | 25-NOV-14:50 |
| General:Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 31.36 | 0.00 | 25-JAN-13:20 | 2561.09 | 25-NOV-14:50 |
| EnergyTransfer:Zone:M SW APARTMENT | 66.75 | 0.02 | 11-OCT-20:40 | 6438.93 | 05-FEB-15:20 |
| Heating:EnergyTransfer:Zone:M SW APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 43.69 | 02-OCT-07:30 |
| General:Heating:EnergyTransfer:Zone:M SW APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 43.69 | 02-OCT-07:30 |
| Cooling:EnergyTransfer:Zone:M SW APARTMENT | 66.74 | 0.00 | 22-FEB-11:20 | 6429.80 | 05-FEB-15:20 |
| General:Cooling:EnergyTransfer:Zone:M SW APARTMENT | 66.74 | 0.00 | 22-FEB-11:20 | 6429.80 | 05-FEB-15:20 |
| EnergyTransfer:Zone:M NW APARTMENT | 55.51 | 0.05 | 04-JAN-13:20 | 5884.24 | 07-JUN-17:10 |
| Heating:EnergyTransfer:Zone:M NW APARTMENT | 0.02 | 0.00 | 01-JAN-00:10 | 87.19 | 22-NOV-12:20 |
| General:Heating:EnergyTransfer:Zone:M NW APARTMENT | 0.02 | 0.00 | 01-JAN-00:10 | 87.19 | 22-NOV-12:20 |
| Cooling:EnergyTransfer:Zone:M NW APARTMENT | 55.49 | 0.00 | 04-JAN-13:20 | 5884.24 | 07-JUN-17:10 |
| General:Cooling:EnergyTransfer:Zone:M NW APARTMENT | 55.49 | 0.00 | 04-JAN-13:20 | 5884.24 | 07-JUN-17:10 |
| EnergyTransfer:Zone:M SE APARTMENT | 66.88 | 0.01 | 13-MAY-06:50 | 6210.04 | 19-FEB-13:50 |
| Heating:EnergyTransfer:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 40.57 | 02-OCT-07:30 |
| General:Heating:EnergyTransfer:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:10 | 40.57 | 02-OCT-07:30 |
| Cooling:EnergyTransfer:Zone:M SE APARTMENT | 66.88 | 0.00 | 11-MAR-06:20 | 6197.32 | 19-FEB-13:50 |
| General:Cooling:EnergyTransfer:Zone:M SE APARTMENT | 66.88 | 0.00 | 11-MAR-06:20 | 6197.32 | 19-FEB-13:50 |
| EnergyTransfer:Zone:M NE APARTMENT | 55.48 | 0.01 | 10-MAR-09:20 | 5000.24 | 12-JUN-17:20 |
| Heating:EnergyTransfer:Zone:M NE APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 61.05 | 25-DEC-14:40 |
| General:Heating:EnergyTransfer:Zone:M NE APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 61.05 | 25-DEC-14:40 |
| Cooling:EnergyTransfer:Zone:M NE APARTMENT | 55.47 | 0.00 | 04-JAN-13:30 | 5000.24 | 12-JUN-17:20 |
| General:Cooling:EnergyTransfer:Zone:M NE APARTMENT | 55.47 | 0.00 | 04-JAN-13:30 | 5000.24 | 12-JUN-17:20 |
| EnergyTransfer:Zone:M N1 APARTMENT | 45.35 | 0.13 | 13-MAY-06:40 | 3992.23 | 17-MAR-18:00 |
| Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.02 | 0.00 | 01-JAN-00:10 | 66.93 | 06-FEB-14:10 |
| General:Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.02 | 0.00 | 01-JAN-00:10 | 66.93 | 06-FEB-14:10 |
| Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 45.33 | 0.00 | 04-JAN-14:00 | 3979.78 | 17-MAR-18:00 |
| General:Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 45.33 | 0.00 | 04-JAN-14:00 | 3979.78 | 17-MAR-18:00 |
| EnergyTransfer:Zone:M N2 APARTMENT | 45.38 | 0.11 | 20-OCT-08:10 | 3993.29 | 17-MAR-18:00 |
| Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.02 | 0.00 | 01-JAN-00:10 | 65.97 | 06-FEB-14:10 |
| General:Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.02 | 0.00 | 01-JAN-00:10 | 65.97 | 06-FEB-14:10 |
| Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 45.37 | 0.00 | 04-JAN-14:00 | 3980.82 | 17-MAR-18:00 |
| General:Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 45.37 | 0.00 | 04-JAN-14:00 | 3980.82 | 17-MAR-18:00 |
| EnergyTransfer:Zone:M S1 APARTMENT | 57.73 | 0.04 | 24-APR-06:30 | 5879.14 | 02-DEC-14:30 |
| Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 43.92 | 02-OCT-07:30 |
| General:Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 43.92 | 02-OCT-07:30 |
| Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 57.73 | 0.00 | 22-FEB-11:20 | 5879.14 | 02-DEC-14:30 |
| General:Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 57.73 | 0.00 | 22-FEB-11:20 | 5879.14 | 02-DEC-14:30 |
| EnergyTransfer:Zone:M S2 APARTMENT | 57.76 | 0.02 | 24-APR-06:30 | 5887.33 | 02-DEC-14:30 |
| Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 43.90 | 02-OCT-07:30 |
| General:Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 43.90 | 02-OCT-07:30 |
| Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 57.76 | 0.00 | 22-FEB-11:20 | 5887.33 | 02-DEC-14:30 |
| General:Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 57.76 | 0.00 | 22-FEB-11:20 | 5887.33 | 02-DEC-14:30 |
| EnergyTransfer:Zone:T SW APARTMENT | 34.95 | 0.03 | 08-MAR-10:20 | 3920.78 | 06-JUN-16:10 |
| Heating:EnergyTransfer:Zone:T SW APARTMENT | 0.16 | 0.00 | 01-JAN-10:00 | 625.21 | 02-JAN-07:00 |
| General:Heating:EnergyTransfer:Zone:T SW APARTMENT | 0.16 | 0.00 | 01-JAN-10:00 | 625.21 | 02-JAN-07:00 |
| Cooling:EnergyTransfer:Zone:T SW APARTMENT | 34.79 | 0.00 | 01-JAN-00:10 | 3920.78 | 06-JUN-16:10 |
| General:Cooling:EnergyTransfer:Zone:T SW APARTMENT | 34.79 | 0.00 | 01-JAN-00:10 | 3920.78 | 06-JUN-16:10 |
| EnergyTransfer:Zone:T NW APARTMENT | 30.23 | 0.01 | 04-FEB-09:40 | 3929.44 | 08-JUN-16:40 |
| Heating:EnergyTransfer:Zone:T NW APARTMENT | 0.51 | 0.00 | 01-JAN-12:00 | 815.64 | 02-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:T NW APARTMENT | 0.51 | 0.00 | 01-JAN-12:00 | 815.64 | 02-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:T NW APARTMENT | 29.72 | 0.00 | 01-JAN-00:10 | 3929.44 | 08-JUN-16:40 |
| General:Cooling:EnergyTransfer:Zone:T NW APARTMENT | 29.72 | 0.00 | 01-JAN-00:10 | 3929.44 | 08-JUN-16:40 |
| EnergyTransfer:Zone:T SE APARTMENT | 34.90 | 0.00 | 13-MAY-07:00 | 3749.92 | 19-FEB-13:50 |
| Heating:EnergyTransfer:Zone:T SE APARTMENT | 0.15 | 0.00 | 01-JAN-09:30 | 637.01 | 02-JAN-07:00 |
| General:Heating:EnergyTransfer:Zone:T SE APARTMENT | 0.15 | 0.00 | 01-JAN-09:30 | 637.01 | 02-JAN-07:00 |
| Cooling:EnergyTransfer:Zone:T SE APARTMENT | 34.75 | 0.00 | 01-JAN-00:10 | 3749.92 | 19-FEB-13:50 |
| General:Cooling:EnergyTransfer:Zone:T SE APARTMENT | 34.75 | 0.00 | 01-JAN-00:10 | 3749.92 | 19-FEB-13:50 |
| EnergyTransfer:Zone:T NE APARTMENT | 30.13 | 0.02 | 08-FEB-18:40 | 3321.05 | 06-JUN-16:10 |
| Heating:EnergyTransfer:Zone:T NE APARTMENT | 0.47 | 0.00 | 01-JAN-11:10 | 833.90 | 02-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:T NE APARTMENT | 0.47 | 0.00 | 01-JAN-11:10 | 833.90 | 02-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:T NE APARTMENT | 29.66 | 0.00 | 01-JAN-00:10 | 3321.05 | 06-JUN-16:10 |
| General:Cooling:EnergyTransfer:Zone:T NE APARTMENT | 29.66 | 0.00 | 01-JAN-00:10 | 3321.05 | 06-JUN-16:10 |
| EnergyTransfer:Zone:T N1 APARTMENT | 24.19 | 0.00 | 08-FEB-18:40 | 2594.75 | 12-JUN-17:10 |
| Heating:EnergyTransfer:Zone:T N1 APARTMENT | 0.16 | 0.00 | 01-JAN-11:10 | 462.60 | 02-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:T N1 APARTMENT | 0.16 | 0.00 | 01-JAN-11:10 | 462.60 | 02-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 24.03 | 0.00 | 01-JAN-00:10 | 2594.75 | 12-JUN-17:10 |
| General:Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 24.03 | 0.00 | 01-JAN-00:10 | 2594.75 | 12-JUN-17:10 |
| EnergyTransfer:Zone:T N2 APARTMENT | 24.21 | 0.02 | 01-FEB-14:10 | 2581.83 | 12-JUN-17:10 |
| Heating:EnergyTransfer:Zone:T N2 APARTMENT | 0.16 | 0.00 | 01-JAN-11:00 | 464.72 | 02-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:T N2 APARTMENT | 0.16 | 0.00 | 01-JAN-11:00 | 464.72 | 02-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 24.05 | 0.00 | 01-JAN-00:10 | 2581.83 | 12-JUN-17:10 |
| General:Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 24.05 | 0.00 | 01-JAN-00:10 | 2581.83 | 12-JUN-17:10 |
| EnergyTransfer:Zone:T S1 APARTMENT | 29.34 | 0.06 | 03-APR-07:00 | 3415.47 | 19-FEB-13:50 |
| Heating:EnergyTransfer:Zone:T S1 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 245.32 | 02-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:T S1 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 245.32 | 02-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 29.33 | 0.00 | 01-JAN-02:30 | 3415.47 | 19-FEB-13:50 |
| General:Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 29.33 | 0.00 | 01-JAN-02:30 | 3415.47 | 19-FEB-13:50 |
| EnergyTransfer:Zone:T S2 APARTMENT | 29.37 | 0.03 | 25-JAN-13:20 | 3449.02 | 19-FEB-13:50 |
| Heating:EnergyTransfer:Zone:T S2 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 246.44 | 02-JAN-06:00 |
| General:Heating:EnergyTransfer:Zone:T S2 APARTMENT | 0.01 | 0.00 | 01-JAN-00:10 | 246.44 | 02-JAN-06:00 |
| Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 29.35 | 0.00 | 01-JAN-02:20 | 3449.02 | 19-FEB-13:50 |
| General:Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 29.35 | 0.00 | 01-JAN-02:20 | 3449.02 | 19-FEB-13:50 |
| EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| PlantLoopHeatingDemand:Facility | 249.09 | 115.79 | 19-JUL-02:50 | 18552.80 | 17-JAN-07:40 |
| PlantLoopHeatingDemand:Plant | 249.09 | 115.79 | 19-JUL-02:50 | 18552.80 | 17-JAN-07:40 |
| WaterSystems:PlantLoopHeatingDemand | 249.09 | 115.79 | 19-JUL-02:50 | 18552.80 | 17-JAN-07:40 |
| General:WaterSystems:PlantLoopHeatingDemand | 249.09 | 115.79 | 19-JUL-02:50 | 18552.80 | 17-JAN-07:40 |
| EnergyTransfer:HVAC | 1475.07 | 57.17 | 30-MAR-19:20 | 122248.48 | 01-JUL-16:30 |
| HeatRecoveryForHeating:EnergyTransfer | 68.30 | 0.00 | 07-FEB-14:40 | 13280.15 | 05-JAN-07:00 |
| HeatRecoveryForCooling:EnergyTransfer | 170.27 | 0.00 | 01-JAN-00:10 | 19743.97 | 01-JUL-17:00 |
| CoolingCoils:EnergyTransfer | 1234.35 | 0.00 | 01-JAN-00:10 | 102535.55 | 01-JUL-16:30 |
| HeatingCoils:EnergyTransfer | 2.15 | 0.00 | 01-JAN-12:10 | 5241.60 | 02-JAN-06:00 |
| EnergyTransfer:Plant | 249.08 | 115.79 | 19-JUL-02:50 | 18550.91 | 17-JAN-07:40 |
| WaterSystems:EnergyTransfer | 249.08 | 115.79 | 19-JUL-02:50 | 18550.91 | 17-JAN-07:40 |
| WaterUse:WaterSystems:EnergyTransfer | 249.08 | 115.79 | 19-JUL-02:50 | 18550.91 | 17-JAN-07:40 |
| Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Annual Building Sensible Heat Gain Components| HVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
| G SW APARTMENT | 1.808 | -0.790 | 0.000 | -34.122 | 0.000 | 0.000 | 3.524 | 0.918 | 12.213 | 10.739 | 0.000 | 0.223 | 9.026 | 0.000 | -2.798 | 0.000 | -0.740 | -0.000 |
| G NW APARTMENT | 1.806 | -0.731 | 0.002 | -29.053 | 0.000 | 0.000 | 3.601 | 0.918 | 12.213 | 7.251 | 0.000 | 0.223 | 7.287 | 0.000 | -2.795 | 0.000 | -0.722 | -0.000 |
| OFFICE | 0.000 | 0.000 | 3.960 | -24.463 | 0.000 | 0.000 | 2.002 | 5.679 | 7.520 | 9.774 | 0.000 | 0.148 | 0.000 | 0.000 | -3.354 | 0.000 | -0.108 | -1.158 |
| G NE APARTMENT | 1.805 | -0.736 | 0.002 | -29.043 | 0.000 | 0.000 | 3.601 | 0.918 | 12.213 | 7.116 | 0.000 | 0.223 | 7.305 | 0.000 | -2.655 | 0.000 | -0.747 | -0.000 |
| G N1 APARTMENT | 1.806 | -0.754 | 0.000 | -24.399 | 0.000 | 0.000 | 3.586 | 0.918 | 12.213 | 3.431 | 0.000 | 0.135 | 5.545 | 0.000 | -1.744 | 0.000 | -0.737 | -0.000 |
| G N2 APARTMENT | 1.806 | -0.754 | 0.000 | -24.412 | 0.000 | 0.000 | 3.586 | 0.918 | 12.213 | 3.430 | 0.000 | 0.135 | 5.561 | 0.000 | -1.744 | 0.000 | -0.738 | -0.000 |
| G S1 APARTMENT | 1.808 | -0.802 | 0.000 | -30.134 | 0.000 | 0.000 | 3.516 | 0.918 | 12.213 | 6.987 | 0.000 | 0.135 | 7.738 | 0.000 | -1.691 | 0.000 | -0.687 | -0.000 |
| G S2 APARTMENT | 1.808 | -0.805 | 0.000 | -32.358 | 0.000 | 0.000 | 3.514 | 0.918 | 12.213 | 6.959 | 0.000 | 0.135 | 9.991 | 0.000 | -1.701 | 0.000 | -0.673 | -0.000 |
| M SW APARTMENT | 3.615 | -1.589 | 0.000 | -68.761 | 0.000 | 0.000 | 7.043 | 1.837 | 24.426 | 21.597 | 0.000 | 0.640 | 18.329 | 0.000 | -5.583 | 0.000 | -1.552 | -0.000 |
| M NW APARTMENT | 3.612 | -1.472 | 0.000 | -57.616 | 0.000 | 0.000 | 7.194 | 1.837 | 24.426 | 14.653 | 0.000 | 0.639 | 13.930 | 0.000 | -5.616 | 0.000 | -1.587 | -0.000 |
| M SE APARTMENT | 3.615 | -1.598 | 0.000 | -68.892 | 0.000 | 0.000 | 7.042 | 1.837 | 24.426 | 21.475 | 0.000 | 0.640 | 18.429 | 0.000 | -5.442 | 0.000 | -1.532 | -0.000 |
| M NE APARTMENT | 3.609 | -1.483 | 0.001 | -57.583 | 0.000 | 0.000 | 7.194 | 1.837 | 24.426 | 14.378 | 0.000 | 0.639 | 13.997 | 0.000 | -5.330 | 0.000 | -1.684 | -0.000 |
| M N1 APARTMENT | 3.611 | -1.521 | 0.000 | -47.409 | 0.000 | 0.000 | 7.163 | 1.837 | 24.426 | 6.955 | 0.000 | 0.386 | 9.762 | 0.000 | -3.510 | 0.000 | -1.700 | -0.000 |
| M N2 APARTMENT | 3.611 | -1.521 | 0.000 | -47.443 | 0.000 | 0.000 | 7.163 | 1.837 | 24.426 | 6.953 | 0.000 | 0.386 | 9.800 | 0.000 | -3.511 | 0.000 | -1.701 | -0.000 |
| M S1 APARTMENT | 3.615 | -1.611 | 0.000 | -59.723 | 0.000 | 0.000 | 7.029 | 1.837 | 24.426 | 14.038 | 0.000 | 0.386 | 14.779 | 0.000 | -3.369 | 0.000 | -1.406 | -0.000 |
| M S2 APARTMENT | 3.615 | -1.611 | 0.000 | -59.756 | 0.000 | 0.000 | 7.029 | 1.837 | 24.426 | 14.037 | 0.000 | 0.386 | 14.812 | 0.000 | -3.369 | 0.000 | -1.405 | -0.000 |
| T SW APARTMENT | 1.809 | -0.700 | 0.240 | -35.981 | 0.000 | 0.000 | 3.589 | 0.918 | 12.213 | 10.676 | 0.000 | 0.421 | 10.134 | 0.000 | -2.542 | 0.000 | -0.776 | -0.000 |
| T NW APARTMENT | 1.810 | -0.623 | 0.663 | -31.061 | 0.000 | 0.000 | 3.673 | 0.918 | 12.213 | 7.241 | 0.000 | 0.421 | 7.954 | 0.000 | -2.512 | 0.000 | -0.698 | -0.000 |
| T SE APARTMENT | 1.808 | -0.709 | 0.225 | -35.928 | 0.000 | 0.000 | 3.590 | 0.918 | 12.213 | 10.615 | 0.000 | 0.421 | 10.135 | 0.000 | -2.480 | 0.000 | -0.806 | -0.001 |
| T NE APARTMENT | 1.806 | -0.625 | 0.621 | -30.998 | 0.000 | 0.000 | 3.677 | 0.918 | 12.213 | 7.124 | 0.000 | 0.421 | 7.997 | 0.000 | -2.388 | 0.000 | -0.765 | -0.001 |
| T N1 APARTMENT | 1.809 | -0.644 | 0.250 | -25.285 | 0.000 | 0.000 | 3.658 | 0.918 | 12.213 | 3.442 | 0.000 | 0.254 | 5.676 | 0.000 | -1.574 | 0.000 | -0.718 | -0.000 |
| T N2 APARTMENT | 1.809 | -0.644 | 0.251 | -25.302 | 0.000 | 0.000 | 3.658 | 0.918 | 12.213 | 3.440 | 0.000 | 0.254 | 5.696 | 0.000 | -1.573 | 0.000 | -0.719 | -0.000 |
| T S1 APARTMENT | 1.808 | -0.739 | 0.029 | -30.413 | 0.000 | 0.000 | 3.563 | 0.918 | 12.213 | 6.955 | 0.000 | 0.254 | 7.731 | 0.000 | -1.568 | 0.000 | -0.753 | -0.000 |
| T S2 APARTMENT | 1.808 | -0.739 | 0.029 | -30.435 | 0.000 | 0.000 | 3.563 | 0.918 | 12.213 | 6.953 | 0.000 | 0.254 | 7.755 | 0.000 | -1.567 | 0.000 | -0.752 | -0.000 |
| T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.394 | 9.711 | 0.000 | 0.854 | 0.000 | 0.048 | 0.000 | 0.000 | -0.269 | 0.000 | -0.029 | -15.710 |
| G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.705 | 9.711 | 3.395 | 2.368 | 0.000 | 5.083 | 0.000 | 0.000 | -0.916 | 0.000 | -8.516 | -15.831 |
| M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 10.482 | 19.423 | 0.000 | 1.705 | 0.000 | 0.079 | 0.000 | 0.000 | -0.594 | 0.000 | -0.052 | -31.042 |
| Total Facility | 56.018 | -23.202 | 6.273 | -940.570 | 0.000 | 0.000 | 133.340 | 72.996 | 389.511 | 231.146 | 0.000 | 13.365 | 229.368 | 0.000 | -72.197 | 0.000 | -32.306 | -63.746 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| G SW APARTMENT | 08-DEC-17:01 | 0.00 | -37.73 | 0.00 | -5837.74 | 0.00 | 0.00 | 0.00 | 54.82 | 588.62 | 50.90 | 0.00 | 0.00 | 5181.13 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 23-NOV-21:12 | 0.00 | -64.40 | 0.00 | -5688.65 | 0.00 | 0.00 | 148.42 | 60.30 | 500.33 | 0.00 | 0.00 | 0.00 | 5397.46 | 0.00 | -353.46 | 0.00 | 0.00 | 0.00 |
| OFFICE | 27-NOV-07:01 | 0.00 | 0.00 | 0.00 | -7111.56 | 0.00 | 0.00 | 0.00 | 89.52 | 194.98 | 0.00 | 0.00 | 0.00 | 7218.62 | 0.00 | -391.56 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 23-NOV-21:12 | 0.00 | -64.56 | 0.00 | -5510.43 | 0.00 | 0.00 | 149.22 | 60.30 | 500.33 | 0.00 | 0.00 | 0.00 | 5217.16 | 0.00 | -352.02 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 23-NOV-21:12 | 0.00 | -68.86 | 0.00 | -4917.52 | 0.00 | 0.00 | 147.93 | 60.30 | 500.33 | 0.00 | 0.00 | 0.00 | 4491.48 | 0.00 | -213.66 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 23-NOV-21:12 | 0.00 | -68.87 | 0.00 | -4914.96 | 0.00 | 0.00 | 147.94 | 60.30 | 500.33 | 0.00 | 0.00 | 0.00 | 4488.90 | 0.00 | -213.64 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 09-DEC-19:12 | 0.00 | -79.97 | 0.00 | -5037.30 | 0.00 | 0.00 | 145.07 | 87.71 | 547.42 | 0.00 | 0.00 | 0.00 | 4567.12 | 0.00 | -226.40 | 0.00 | -3.65 | 0.00 |
| G S2 APARTMENT | 09-DEC-19:12 | 0.00 | -79.77 | 0.00 | -5077.56 | 0.00 | 0.00 | 145.07 | 87.71 | 547.42 | 0.00 | 0.00 | 0.00 | 4607.17 | 0.00 | -226.40 | 0.00 | -3.65 | 0.00 |
| M SW APARTMENT | 08-DEC-17:01 | 0.00 | -72.70 | 0.00 | -12813.41 | 0.00 | 0.00 | 0.00 | 109.64 | 1177.25 | 93.22 | 0.00 | 0.00 | 11506.01 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 23-NOV-21:12 | 0.00 | -118.98 | 0.00 | -12436.45 | 0.00 | 0.00 | 302.47 | 120.61 | 1000.66 | 0.00 | 0.00 | 0.00 | 11831.46 | 0.00 | -699.77 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 08-DEC-17:01 | 0.00 | -73.15 | 0.00 | -12362.55 | 0.00 | 0.00 | 0.00 | 109.64 | 1177.25 | 0.00 | 0.00 | 0.00 | 11368.60 | 0.00 | -219.78 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 19-MAR-20:12 | 0.00 | -6.34 | 0.00 | -12106.19 | 0.00 | 0.00 | 290.14 | 120.61 | 1000.66 | 0.00 | 0.00 | 0.00 | 11157.32 | 0.00 | -426.47 | 0.00 | -29.72 | 0.00 |
| M N1 APARTMENT | 01-DEC-20:12 | 0.00 | -154.29 | 0.00 | -10581.81 | 0.00 | 0.00 | 261.97 | 175.43 | 1047.75 | 0.00 | 0.00 | 0.00 | 9721.96 | 0.00 | -455.65 | 0.00 | -15.36 | 0.00 |
| M N2 APARTMENT | 01-DEC-20:12 | 0.00 | -154.27 | 0.00 | -10574.80 | 0.00 | 0.00 | 262.06 | 175.43 | 1047.75 | 0.00 | 0.00 | 0.00 | 9714.69 | 0.00 | -455.50 | 0.00 | -15.36 | 0.00 |
| M S1 APARTMENT | 08-DEC-17:01 | 0.00 | -79.08 | 0.00 | -10935.46 | 0.00 | 0.00 | 0.00 | 109.64 | 1177.25 | 0.00 | 0.00 | 0.00 | 9768.15 | 0.00 | -40.50 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 08-DEC-17:01 | 0.00 | -79.09 | 0.00 | -10928.00 | 0.00 | 0.00 | 0.00 | 109.64 | 1177.25 | 0.00 | 0.00 | 0.00 | 9760.69 | 0.00 | -40.48 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 15-FEB-14:22 | 0.00 | 4.89 | 0.00 | -7099.02 | 0.00 | 0.00 | 0.00 | 10.96 | 382.60 | 857.51 | 0.00 | 0.00 | 5852.27 | 0.00 | -0.00 | 0.00 | -9.22 | 0.00 |
| T NW APARTMENT | 22-MAR-20:12 | 0.00 | 17.23 | 0.00 | -6883.54 | 0.00 | 0.00 | 145.07 | 60.30 | 500.33 | 0.00 | 0.00 | 0.00 | 6313.39 | 0.00 | -142.67 | 0.00 | -10.11 | 0.00 |
| T SE APARTMENT | 15-FEB-14:22 | 0.00 | 1.60 | 0.00 | -6846.33 | 0.00 | 0.00 | 0.00 | 10.96 | 382.60 | 627.26 | 0.00 | 0.00 | 5833.74 | 0.00 | -0.00 | 0.00 | -9.83 | 0.00 |
| T NE APARTMENT | 21-MAR-19:42 | 0.00 | 5.54 | 0.00 | -6572.89 | 0.00 | 0.00 | 126.21 | 87.71 | 523.87 | 0.00 | 0.00 | 0.00 | 5996.76 | 0.00 | -151.88 | 0.00 | -15.33 | 0.00 |
| T N1 APARTMENT | 21-MAR-19:42 | 0.00 | 2.59 | 0.00 | -5953.39 | 0.00 | 0.00 | 126.21 | 87.71 | 523.87 | 0.00 | 0.00 | 0.00 | 5314.13 | 0.00 | -91.65 | 0.00 | -9.48 | 0.00 |
| T N2 APARTMENT | 21-MAR-19:42 | 0.00 | 2.48 | 0.00 | -5944.17 | 0.00 | 0.00 | 126.21 | 87.71 | 523.87 | 0.00 | 0.00 | 0.00 | 5305.19 | 0.00 | -91.81 | 0.00 | -9.49 | 0.00 |
| T S1 APARTMENT | 15-FEB-14:22 | 0.00 | 1.67 | 0.00 | -6142.92 | 0.00 | 0.00 | 0.00 | 10.96 | 382.60 | 559.20 | 0.00 | 0.00 | 5194.07 | 0.00 | -0.00 | 0.00 | -5.60 | 0.00 |
| T S2 APARTMENT | 15-FEB-14:22 | 0.00 | 1.35 | 0.00 | -6140.23 | 0.00 | 0.00 | 0.00 | 10.96 | 382.60 | 558.56 | 0.00 | 0.00 | 5192.41 | 0.00 | -0.00 | 0.00 | -5.65 | 0.00 |
| T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 21-MAR-15:42 | 0.00 | 690.91 | 0.00 | -181252.98 | 0.00 | 0.00 | 1299.03 | 2868.98 | 15265.96 | 6887.82 | 0.00 | 0.00 | 154648.31 | 0.00 | 0.00 | 0.00 | -408.03 | 0.00 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| G SW APARTMENT | 02-OCT-07:35 | 58.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.45 | 388.49 | 183.08 | 0.00 | 0.86 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -647.36 |
| G NW APARTMENT | 04-NOV-10:55 | 64.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.59 | 10.96 | 412.04 | 296.46 | 0.00 | 3.96 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -824.23 |
| OFFICE | 08-JUN-16:01 | 0.00 | 0.00 | 1190.76 | 0.00 | 0.00 | 0.00 | 0.00 | 89.52 | 194.98 | 742.64 | 0.00 | 5.51 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -2223.42 |
| G NE APARTMENT | 04-NOV-10:55 | 65.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.27 | 10.96 | 412.04 | 483.02 | 0.00 | 4.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1012.12 |
| G N1 APARTMENT | 04-NOV-10:55 | 66.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.55 | 10.96 | 412.04 | 178.75 | 0.00 | 2.44 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -707.47 |
| G N2 APARTMENT | 04-NOV-10:55 | 66.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.51 | 10.96 | 412.04 | 178.50 | 0.00 | 2.44 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -707.36 |
| G S1 APARTMENT | 28-MAR-09:15 | 59.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.96 | 406.15 | 430.33 | 0.00 | 0.70 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -907.46 |
| G S2 APARTMENT | 28-MAR-09:15 | 58.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.96 | 406.15 | 428.54 | 0.00 | 0.68 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -905.12 |
| M SW APARTMENT | 28-MAR-09:15 | 113.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.93 | 812.30 | 1072.17 | 0.00 | 3.25 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -2022.66 |
| M NW APARTMENT | 10-MAR-10:15 | 115.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 74.18 | 21.93 | 812.30 | 693.20 | 0.00 | 12.03 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1729.48 |
| M SE APARTMENT | 28-MAR-09:15 | 115.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.93 | 812.30 | 2316.29 | 0.00 | 3.28 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -3269.37 |
| M NE APARTMENT | 04-NOV-10:55 | 126.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.57 | 21.93 | 824.07 | 972.39 | 0.00 | 11.19 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -2028.97 |
| M N1 APARTMENT | 04-NOV-10:55 | 120.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 75.26 | 21.93 | 824.07 | 366.38 | 0.00 | 6.59 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1414.93 |
| M N2 APARTMENT | 04-NOV-10:55 | 121.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 75.15 | 21.93 | 824.07 | 365.78 | 0.00 | 6.61 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1414.75 |
| M S1 APARTMENT | 28-MAR-09:15 | 118.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.93 | 812.30 | 853.63 | 0.00 | 2.01 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1807.90 |
| M S2 APARTMENT | 28-MAR-09:15 | 118.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.93 | 812.30 | 853.15 | 0.00 | 2.01 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1807.77 |
| T SW APARTMENT | 02-JAN-07:00 | -124.88 | 0.00 | 750.07 | 0.00 | 0.00 | 0.00 | 194.99 | 38.37 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -413.23 | 0.00 | 0.00 | -763.19 |
| T NW APARTMENT | 02-JAN-06:00 | -127.98 | 0.00 | 943.60 | 0.00 | 0.00 | 0.00 | 194.99 | 35.63 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -417.93 | 0.00 | 0.00 | -881.41 |
| T SE APARTMENT | 02-JAN-07:00 | -124.88 | 0.00 | 761.88 | 0.00 | 0.00 | 0.00 | 194.99 | 38.37 | 317.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -412.86 | 0.00 | 0.00 | -775.36 |
| T NE APARTMENT | 02-JAN-06:00 | -127.98 | 0.00 | 961.85 | 0.00 | 0.00 | 0.00 | 194.99 | 35.63 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -417.42 | 0.00 | 0.00 | -900.19 |
| T N1 APARTMENT | 02-JAN-06:00 | -127.98 | 0.00 | 590.57 | 0.00 | 0.00 | 0.00 | 194.99 | 35.63 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -257.39 | 0.00 | 0.00 | -688.93 |
| T N2 APARTMENT | 02-JAN-06:00 | -127.98 | 0.00 | 592.69 | 0.00 | 0.00 | 0.00 | 194.99 | 35.63 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -257.35 | 0.00 | 0.00 | -691.08 |
| T S1 APARTMENT | 02-JAN-06:00 | -128.01 | 0.00 | 373.33 | 0.00 | 0.00 | 0.00 | 194.99 | 35.63 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -262.31 | 0.00 | 0.00 | -466.73 |
| T S2 APARTMENT | 02-JAN-06:00 | -128.01 | 0.00 | 374.44 | 0.00 | 0.00 | 0.00 | 194.99 | 35.63 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -262.29 | 0.00 | 0.00 | -467.87 |
| T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 03-JAN-07:01 | -4527.47 | 0.00 | 6038.36 | 0.00 | 0.00 | 0.00 | 6387.03 | 2425.88 | 12245.92 | 0.00 | 0.00 | 0.00 | 492.93 | 0.00 | -13030.49 | 0.00 | -10032.16 | 0.00 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
System Ventilation Requirements for Cooling| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| SPLIT GSW | 0.3645 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3645 | 0.0712 | 1.0000 | Not calculated | 0.0260 | 0.0712 | ||
| SPLIT GNW | 0.3638 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3638 | 0.0714 | 1.0000 | Not calculated | 0.0260 | 0.0714 | ||
| SPLIT OFFICE | 0.4255 | 0.0000 | 4.7495 | 1.0000 | Calculated from schedules | 0.0381 | 0.4255 | 0.0896 | 1.0000 | Not calculated | 0.0381 | 0.0896 | ||
| SPLIT GNE | 0.3504 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3504 | 0.0741 | 1.0000 | Not calculated | 0.0260 | 0.0741 | ||
| SPLIT GN1 | 0.3052 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3052 | 0.0850 | 1.0000 | Not calculated | 0.0260 | 0.0850 | ||
| SPLIT GN2 | 0.3050 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3050 | 0.0851 | 1.0000 | Not calculated | 0.0260 | 0.0851 | ||
| SPLIT GS1 | 0.3065 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3065 | 0.0847 | 1.0000 | Not calculated | 0.0260 | 0.0847 | ||
| SPLIT GS2 | 0.3095 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3095 | 0.0839 | 1.0000 | Not calculated | 0.0260 | 0.0839 | ||
| SPLIT MSW | 0.8115 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8115 | 0.0640 | 1.0000 | Not calculated | 0.0519 | 0.0640 | ||
| SPLIT MNW | 0.8098 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8098 | 0.0641 | 1.0000 | Not calculated | 0.0519 | 0.0641 | ||
| SPLIT MSE | 0.7786 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7786 | 0.0667 | 1.0000 | Not calculated | 0.0519 | 0.0667 | ||
| SPLIT MNE | 0.7770 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7770 | 0.0668 | 1.0000 | Not calculated | 0.0519 | 0.0668 | ||
| SPLIT MN1 | 0.6680 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6680 | 0.0777 | 1.0000 | Not calculated | 0.0519 | 0.0777 | ||
| SPLIT MN2 | 0.6675 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6675 | 0.0778 | 1.0000 | Not calculated | 0.0519 | 0.0778 | ||
| SPLIT MS1 | 0.6705 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6705 | 0.0774 | 1.0000 | Not calculated | 0.0519 | 0.0774 | ||
| SPLIT MS2 | 0.6700 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6700 | 0.0775 | 1.0000 | Not calculated | 0.0519 | 0.0775 | ||
| SPLIT TSW | 0.4492 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4492 | 0.0578 | 1.0000 | Not calculated | 0.0260 | 0.0578 | ||
| SPLIT TNW | 0.4505 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4505 | 0.0576 | 1.0000 | Not calculated | 0.0260 | 0.0576 | ||
| SPLIT TSE | 0.4257 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4257 | 0.0610 | 1.0000 | Not calculated | 0.0260 | 0.0610 | ||
| SPLIT TNE | 0.4271 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4271 | 0.0608 | 1.0000 | Not calculated | 0.0260 | 0.0608 | ||
| SPLIT TN1 | 0.3805 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3805 | 0.0682 | 1.0000 | Not calculated | 0.0260 | 0.0682 | ||
| SPLIT TN2 | 0.3797 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3797 | 0.0684 | 1.0000 | Not calculated | 0.0260 | 0.0684 | ||
| SPLIT TS1 | 0.3793 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3793 | 0.0684 | 1.0000 | Not calculated | 0.0260 | 0.0684 | ||
| SPLIT TS2 | 0.3786 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3786 | 0.0686 | 1.0000 | Not calculated | 0.0260 | 0.0686 |
| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| SPLIT GSW | 0.3645 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3645 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0712 | ||
| SPLIT GNW | 0.3638 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3638 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0714 | ||
| SPLIT OFFICE | 0.4255 | 0.0000 | 4.7495 | 1.0000 | Calculated from schedules | 0.0381 | 0.4255 | 1.0000 | 1.0000 | Not calculated | 0.0381 | 0.0896 | ||
| SPLIT GNE | 0.3504 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3504 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0741 | ||
| SPLIT GN1 | 0.3052 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3052 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0850 | ||
| SPLIT GN2 | 0.3050 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3050 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0851 | ||
| SPLIT GS1 | 0.3065 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3065 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0847 | ||
| SPLIT GS2 | 0.3095 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3095 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0839 | ||
| SPLIT MSW | 0.8115 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8115 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0640 | ||
| SPLIT MNW | 0.8098 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.8098 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0641 | ||
| SPLIT MSE | 0.7786 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7786 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0667 | ||
| SPLIT MNE | 0.7770 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.7770 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0668 | ||
| SPLIT MN1 | 0.6680 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6680 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0777 | ||
| SPLIT MN2 | 0.6675 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6675 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0778 | ||
| SPLIT MS1 | 0.6705 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6705 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0774 | ||
| SPLIT MS2 | 0.6700 | 0.0000 | 5.0000 | 1.0000 | Calculated from schedules | 0.0519 | 0.6700 | 1.0000 | 1.0000 | Not calculated | 0.0519 | 0.0775 | ||
| SPLIT TSW | 0.4492 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4492 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0578 | ||
| SPLIT TNW | 0.4505 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4505 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0576 | ||
| SPLIT TSE | 0.4257 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4257 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0610 | ||
| SPLIT TNE | 0.4271 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.4271 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0608 | ||
| SPLIT TN1 | 0.3805 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3805 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0682 | ||
| SPLIT TN2 | 0.3797 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3797 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0684 | ||
| SPLIT TS1 | 0.3793 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3793 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0684 | ||
| SPLIT TS2 | 0.3786 | 0.0000 | 2.5000 | 1.0000 | Calculated from schedules | 0.0260 | 0.3786 | 1.0000 | 1.0000 | Not calculated | 0.0260 | 0.0686 |
| AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| G SW APARTMENT | SPLIT GSW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G NW APARTMENT | SPLIT GNW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| OFFICE | SPLIT OFFICE | 0.000000 | 4.7495 | 0.000432 | 88.25 | 0.0381 | 1.0000 | 0.0381 | 1.000 | 0.0381 |
| G NE APARTMENT | SPLIT GNE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G N1 APARTMENT | SPLIT GN1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G N2 APARTMENT | SPLIT GN2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G S1 APARTMENT | SPLIT GS1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| G S2 APARTMENT | SPLIT GS2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| M SW APARTMENT | SPLIT MSW | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M NW APARTMENT | SPLIT MNW | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M SE APARTMENT | SPLIT MSE | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M NE APARTMENT | SPLIT MNE | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M N1 APARTMENT | SPLIT MN1 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M N2 APARTMENT | SPLIT MN2 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M S1 APARTMENT | SPLIT MS1 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| M S2 APARTMENT | SPLIT MS2 | 0.000000 | 5.0000 | 0.000294 | 176.50 | 0.0519 | 1.0000 | 0.0519 | 1.000 | 0.0519 |
| T SW APARTMENT | SPLIT TSW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T NW APARTMENT | SPLIT TNW | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T SE APARTMENT | SPLIT TSE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T NE APARTMENT | SPLIT TNE | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T N1 APARTMENT | SPLIT TN1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T N2 APARTMENT | SPLIT TN2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T S1 APARTMENT | SPLIT TS1 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| T S2 APARTMENT | SPLIT TS2 | 0.000000 | 2.5000 | 0.000294 | 88.25 | 0.0260 | 1.0000 | 0.0260 | 1.000 | 0.0260 |
| People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| SPLIT GSW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GNW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT OFFICE | 0.000000 | 4.75 | 0.000432 | 88.2493 | 0.0381 | 0.0381 | 0.0381 |
| SPLIT GNE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GN1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GN2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GS1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT GS2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT MSW | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MNW | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MSE | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MNE | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MN1 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MN2 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MS1 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT MS2 | 0.000000 | 5.00 | 0.000294 | 176.4985 | 0.0519 | 0.0519 | 0.0519 |
| SPLIT TSW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TNW | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TSE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TNE | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TN1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TN2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TS1 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| SPLIT TS2 | 0.000000 | 2.50 | 0.000294 | 88.2493 | 0.0260 | 0.0260 | 0.0260 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| G SW APARTMENT | SPLIT GSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3645 | 0.3645 | 0.3645 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NW APARTMENT | SPLIT GNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3638 | 0.3638 | 0.3638 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| OFFICE | SPLIT OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4255 | 0.4255 | 0.4255 | No | 0.0381 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NE APARTMENT | SPLIT GNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3504 | 0.3504 | 0.3504 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N1 APARTMENT | SPLIT GN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3052 | 0.3052 | 0.3052 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N2 APARTMENT | SPLIT GN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3050 | 0.3050 | 0.3050 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S1 APARTMENT | SPLIT GS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3065 | 0.3065 | 0.3065 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S2 APARTMENT | SPLIT GS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3095 | 0.3095 | 0.3095 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SW APARTMENT | SPLIT MSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8115 | 0.8115 | 0.8115 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NW APARTMENT | SPLIT MNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8098 | 0.8098 | 0.8098 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SE APARTMENT | SPLIT MSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7786 | 0.7786 | 0.7786 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NE APARTMENT | SPLIT MNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7770 | 0.7770 | 0.7770 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N1 APARTMENT | SPLIT MN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6680 | 0.6680 | 0.6680 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N2 APARTMENT | SPLIT MN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6675 | 0.6675 | 0.6675 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S1 APARTMENT | SPLIT MS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6705 | 0.6705 | 0.6705 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S2 APARTMENT | SPLIT MS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6700 | 0.6700 | 0.6700 | No | 0.0519 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SW APARTMENT | SPLIT TSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4492 | 0.4492 | 0.4492 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NW APARTMENT | SPLIT TNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4505 | 0.4505 | 0.4505 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SE APARTMENT | SPLIT TSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4257 | 0.4257 | 0.4257 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NE APARTMENT | SPLIT TNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4271 | 0.4271 | 0.4271 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N1 APARTMENT | SPLIT TN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3805 | 0.3805 | 0.3805 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N2 APARTMENT | SPLIT TN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3797 | 0.3797 | 0.3797 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S1 APARTMENT | SPLIT TS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3793 | 0.3793 | 0.3793 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S2 APARTMENT | SPLIT TS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3786 | 0.3786 | 0.3786 | No | 0.0260 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| SPLIT GSW | 0.3645 | 0.3645 | 0.3645 | 0.3645 | 0.0260 | 1.0000 |
| SPLIT GNW | 0.3638 | 0.3638 | 0.3638 | 0.3638 | 0.0260 | 1.0000 |
| SPLIT OFFICE | 0.4255 | 0.4255 | 0.4255 | 0.4255 | 0.0381 | 1.0000 |
| SPLIT GNE | 0.3504 | 0.3504 | 0.3504 | 0.3504 | 0.0260 | 1.0000 |
| SPLIT GN1 | 0.3052 | 0.3052 | 0.3052 | 0.3052 | 0.0260 | 1.0000 |
| SPLIT GN2 | 0.3050 | 0.3050 | 0.3050 | 0.3050 | 0.0260 | 1.0000 |
| SPLIT GS1 | 0.3065 | 0.3065 | 0.3065 | 0.3065 | 0.0260 | 1.0000 |
| SPLIT GS2 | 0.3095 | 0.3095 | 0.3095 | 0.3095 | 0.0260 | 1.0000 |
| SPLIT MSW | 0.8115 | 0.8115 | 0.8115 | 0.8115 | 0.0519 | 1.0000 |
| SPLIT MNW | 0.8098 | 0.8098 | 0.8098 | 0.8098 | 0.0519 | 1.0000 |
| SPLIT MSE | 0.7786 | 0.7786 | 0.7786 | 0.7786 | 0.0519 | 1.0000 |
| SPLIT MNE | 0.7770 | 0.7770 | 0.7770 | 0.7770 | 0.0519 | 1.0000 |
| SPLIT MN1 | 0.6680 | 0.6680 | 0.6680 | 0.6680 | 0.0519 | 1.0000 |
| SPLIT MN2 | 0.6675 | 0.6675 | 0.6675 | 0.6675 | 0.0519 | 1.0000 |
| SPLIT MS1 | 0.6705 | 0.6705 | 0.6705 | 0.6705 | 0.0519 | 1.0000 |
| SPLIT MS2 | 0.6700 | 0.6700 | 0.6700 | 0.6700 | 0.0519 | 1.0000 |
| SPLIT TSW | 0.4492 | 0.4492 | 0.4492 | 0.4492 | 0.0260 | 1.0000 |
| SPLIT TNW | 0.4505 | 0.4505 | 0.4505 | 0.4505 | 0.0260 | 1.0000 |
| SPLIT TSE | 0.4257 | 0.4257 | 0.4257 | 0.4257 | 0.0260 | 1.0000 |
| SPLIT TNE | 0.4271 | 0.4271 | 0.4271 | 0.4271 | 0.0260 | 1.0000 |
| SPLIT TN1 | 0.3805 | 0.3805 | 0.3805 | 0.3805 | 0.0260 | 1.0000 |
| SPLIT TN2 | 0.3797 | 0.3797 | 0.3797 | 0.3797 | 0.0260 | 1.0000 |
| SPLIT TS1 | 0.3793 | 0.3793 | 0.3793 | 0.3793 | 0.0260 | 1.0000 |
| SPLIT TS2 | 0.3786 | 0.3786 | 0.3786 | 0.3786 | 0.0260 | 1.0000 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| G SW APARTMENT | SPLIT GSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3645 | 0.3645 | 0.3645 | No | 0.0260 | 0.6704 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NW APARTMENT | SPLIT GNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3638 | 0.3638 | 0.3638 | No | 0.0260 | 0.8037 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| OFFICE | SPLIT OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4255 | 0.4255 | 0.4255 | No | 0.0381 | 0.6907 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G NE APARTMENT | SPLIT GNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3504 | 0.3504 | 0.3504 | No | 0.0260 | 0.8043 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N1 APARTMENT | SPLIT GN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3052 | 0.3052 | 0.3052 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G N2 APARTMENT | SPLIT GN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3050 | 0.3050 | 0.3050 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S1 APARTMENT | SPLIT GS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3065 | 0.3065 | 0.3065 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| G S2 APARTMENT | SPLIT GS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3095 | 0.3095 | 0.3095 | No | 0.0260 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SW APARTMENT | SPLIT MSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8115 | 0.8115 | 0.8115 | No | 0.0519 | 0.6132 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NW APARTMENT | SPLIT MNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8098 | 0.8098 | 0.8098 | No | 0.0519 | 0.7416 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M SE APARTMENT | SPLIT MSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7786 | 0.7786 | 0.7786 | No | 0.0519 | 0.6136 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M NE APARTMENT | SPLIT MNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.7770 | 0.7770 | 0.7770 | No | 0.0519 | 0.7422 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N1 APARTMENT | SPLIT MN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6680 | 0.6680 | 0.6680 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M N2 APARTMENT | SPLIT MN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6675 | 0.6675 | 0.6675 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S1 APARTMENT | SPLIT MS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6705 | 0.6705 | 0.6705 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| M S2 APARTMENT | SPLIT MS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.6700 | 0.6700 | 0.6700 | No | 0.0519 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SW APARTMENT | SPLIT TSW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4492 | 0.4492 | 0.4492 | No | 0.0260 | 0.3603 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NW APARTMENT | SPLIT TNW | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4505 | 0.4505 | 0.4505 | No | 0.0260 | 0.4042 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T SE APARTMENT | SPLIT TSE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4257 | 0.4257 | 0.4257 | No | 0.0260 | 0.3605 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T NE APARTMENT | SPLIT TNE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.4271 | 0.4271 | 0.4271 | No | 0.0260 | 0.4045 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N1 APARTMENT | SPLIT TN1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3805 | 0.3805 | 0.3805 | No | 0.0260 | 0.6067 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T N2 APARTMENT | SPLIT TN2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3797 | 0.3797 | 0.3797 | No | 0.0260 | 0.6067 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S1 APARTMENT | SPLIT TS1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3793 | 0.3793 | 0.3793 | No | 0.0260 | 0.5123 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| T S2 APARTMENT | SPLIT TS2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.3786 | 0.3786 | 0.3786 | No | 0.0260 | 0.5123 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| SPLIT GSW | 0.3645 | 0.3645 | 0.3645 | 0.3645 | 0.0260 | 1.0000 |
| SPLIT GNW | 0.3638 | 0.3638 | 0.3638 | 0.3638 | 0.0260 | 1.0000 |
| SPLIT OFFICE | 0.4255 | 0.4255 | 0.4255 | 0.4255 | 0.0381 | 1.0000 |
| SPLIT GNE | 0.3504 | 0.3504 | 0.3504 | 0.3504 | 0.0260 | 1.0000 |
| SPLIT GN1 | 0.3052 | 0.3052 | 0.3052 | 0.3052 | 0.0260 | 1.0000 |
| SPLIT GN2 | 0.3050 | 0.3050 | 0.3050 | 0.3050 | 0.0260 | 1.0000 |
| SPLIT GS1 | 0.3065 | 0.3065 | 0.3065 | 0.3065 | 0.0260 | 1.0000 |
| SPLIT GS2 | 0.3095 | 0.3095 | 0.3095 | 0.3095 | 0.0260 | 1.0000 |
| SPLIT MSW | 0.8115 | 0.8115 | 0.8115 | 0.8115 | 0.0519 | 1.0000 |
| SPLIT MNW | 0.8098 | 0.8098 | 0.8098 | 0.8098 | 0.0519 | 1.0000 |
| SPLIT MSE | 0.7786 | 0.7786 | 0.7786 | 0.7786 | 0.0519 | 1.0000 |
| SPLIT MNE | 0.7770 | 0.7770 | 0.7770 | 0.7770 | 0.0519 | 1.0000 |
| SPLIT MN1 | 0.6680 | 0.6680 | 0.6680 | 0.6680 | 0.0519 | 1.0000 |
| SPLIT MN2 | 0.6675 | 0.6675 | 0.6675 | 0.6675 | 0.0519 | 1.0000 |
| SPLIT MS1 | 0.6705 | 0.6705 | 0.6705 | 0.6705 | 0.0519 | 1.0000 |
| SPLIT MS2 | 0.6700 | 0.6700 | 0.6700 | 0.6700 | 0.0519 | 1.0000 |
| SPLIT TSW | 0.4492 | 0.4492 | 0.4492 | 0.4492 | 0.0260 | 1.0000 |
| SPLIT TNW | 0.4505 | 0.4505 | 0.4505 | 0.4505 | 0.0260 | 1.0000 |
| SPLIT TSE | 0.4257 | 0.4257 | 0.4257 | 0.4257 | 0.0260 | 1.0000 |
| SPLIT TNE | 0.4271 | 0.4271 | 0.4271 | 0.4271 | 0.0260 | 1.0000 |
| SPLIT TN1 | 0.3805 | 0.3805 | 0.3805 | 0.3805 | 0.0260 | 1.0000 |
| SPLIT TN2 | 0.3797 | 0.3797 | 0.3797 | 0.3797 | 0.0260 | 1.0000 |
| SPLIT TS1 | 0.3793 | 0.3793 | 0.3793 | 0.3793 | 0.0260 | 1.0000 |
| SPLIT TS2 | 0.3786 | 0.3786 | 0.3786 | 0.3786 | 0.0260 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Sec1.1A-General Information| Data | |
| Weather File | RUNPERIOD 1 ** New Delhi-Safdarjung AP Delhi IND IWEC2 WMO#=421820 |
| Total gross floor area [m2] | 3134.61 |
| Principal Heating Source | Electricity |
| Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
| G SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| OFFICE | 88.25 | 88.25 | 0.00 | 33.56 |
| G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M SE APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T SW APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T SE APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
| T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 117.85 |
| T CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| G CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| M CORRIDOR | 77.66 | 0.00 | 77.66 | 168.00 |
| Totals | 3134.61 | 2823.98 | 310.64 |
| Data | |
| Number of hours heating loads not met | 0.00 |
| Number of hours cooling loads not met | 0.00 |
| Number of hours not met | 0.00 |
| Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
| None |
| Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
| Heating -- General | 0.67 | 1649.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling -- General | 343.35 | 32110.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- LightsWired | 67.97 | 3560.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- LightsPlugIn | 5.02 | 479.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting -- General | 33.03 | 2101.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- ElevatorLift | 67.41 | 3772.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- ElevatorLightsFan | 0.49 | 31.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- MiscPlug | 386.12 | 18442.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- General | 144.96 | 9389.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps -- General | 0.46 | 14.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems -- WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems -- Water Heater | 0.00 | 0.00 | 324.48 | 23788.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Process Subtotal [GJ] | Total Energy Use [GJ] | |
| Electricity | 454.01 | 1049.47 |
| Natural Gas | 0.00 | 324.48 |
| Additional | 0.00 | 0.00 |
| Total | 454.01 | 1373.95 |
| Process Subtotal [$] | Total Energy Cost [$] | |
| Electricity | 0.00 | |
| Natural Gas | 0.00 | |
| Additional | 0.00 | |
| Total | 0.00 |
| Rated Capacity [kW] | Annual Energy Generated [GJ] | |
| Photovoltaic | 0.00 | 0.00 |
| Wind | 0.00 | 0.00 |
| Electricty [MJ/m2] | |
| Interior Lighting (All) | 23.29 |
| Space Heating | 0.21 |
| Space Cooling | 109.53 |
| Fans (All) | 46.25 |
| Service Water Heating | 0.00 |
| Receptacle Equipment | 144.84 |
| Miscellaneous (All) | 334.80 |
| Subtotal | 334.80 |
| Natural Gas [MJ/m2] | |
| Space Heating | 0.00 |
| Service Water Heating | 103.52 |
| Miscellaneous (All) | 103.52 |
| Subtotal | 103.52 |
| Additional [MJ/m2] | |
| Subtotal | 0.00 |
| Miscellaneous | 0.00 |
| Percent [%] | |
| Interior Lighting (All) | 5.31 |
| Space Heating | 0.05 |
| Space Cooling | 24.99 |
| Fans (All) | 10.55 |
| Service Water Heating | 23.62 |
| Receptacle Equipment | 33.04 |
| Miscellaneous | 2.44 |
| Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
| ELEVATOR_RUNNING_SCH | 146. | 3285. |
| ELEVATOR_STANDBY_SCH | 8201. | 8760. |
| OCC_APT_SCH_STAY_HOME_FAMILY | 5993. | 8760. |
| OCC_APT_SCH_CORRIDOR | 5993. | 8760. |
| OCC_APT_SCH_WORKING_FAMILY | 5845. | 6055. |
| OCC_OFF_SCH | 2210. | 2340. |
| OCC_OFF_W_SB_SCH | 1820. | 1820. |
| LTG_SCH_OFFICE | 2435. | 8760. |
| LTG_SCH_CORRIDOR | 6570. | 8760. |
| LTG_SCH_APARTMENT_HARDWIRED | 527. | 8760. |
| LTG_SCH_APARTMENT_PLUGIN | 527. | 8760. |
| EQP_APT_SCH | 5763. | 8760. |
| EQP_OFF_SCH | 3614. | 8760. |
| INF_APT_SCH | 8760. | 8760. |
| INF_OFF_SCH | 8760. | 8760. |
| INF_COR_SCH | 8760. | 8760. |
| INFIL_DOOR_OPENING_SCH | 1466. | 5840. |
| ALL OFF | 0. | 0. |
| ALL ON | 8760. | 8760. |
| ALWAYS_ON | 8760. | 8760. |
| ALLON_EXCEPT_DD | 8760. | 8760. |
| EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
| FAN_OFF_W_SB_SCH | 8240. | 8240. |
| APT_DHW_SCH | 4592. | 8760. |
| EXTERIOR_LTG_SCH | 4380. | 4380. |
| ELEV_LIGHT_FAN_SCH_24_7 | 8760. | 8760. |
| ELEV_LIGHT_FAN_SCH_ADD_DF | 2154. | 8760. |
| SLIDING_DOORS_VENTILATION_AVAILABILITY_SCH | 5840. | 5840. |
| First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
| HTGSETP_APT_SCH | APTHEATINGSETPOINT | January | 21.10 | 365 | 21.10 | 365 |
| HTGSETP_DESIGN_OFF_SCH | OFFHEATINGSETPOINT | January | 21.10 | 365 | 21.10 | 365 |
| CLGSETP_APT_SCH | APTCOOLINGSETPOINT | July | 24.00 | 365 | 24.00 | 365 |
| CLGSETP_DESIGN_OFF_SCH | OFFCOOLINGSETPOINT | July | 23.90 | 365 | 23.90 | 365 |
| S HTGSETP_APT_SCH | S APARTMENT DUAL SP CONTROL | January | 21.10 | 365 | 21.10 | 365 |
| S CLGSETP_APT_SCH | S APARTMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
| N HTGSETP_APT_SCH | N APARTMENT DUAL SP CONTROL | January | 21.10 | 365 | 21.10 | 365 |
| N CLGSETP_APT_SCH | N APARTMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
| HTGSETP_OFF_SCH_NO_OPTIMUM | OFFICE DUAL SP CONTROL | January | 21.10 | 365 | 15.60 | 365 |
| CLGSETP_OFF_SCH_NO_OPTIMUM | OFFICE DUAL SP CONTROL | July | 24.00 | 365 | 29.40 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Heat Index Hours| Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| G SW APARTMENT | 8758.17 | 1.83 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 8759.50 | 0.50 | 0.00 | 0.00 | 0.00 |
| OFFICE | 4594.67 | 3030.83 | 1134.50 | 0.00 | 0.00 |
| G NE APARTMENT | 8759.33 | 0.67 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 8758.83 | 1.17 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 8755.50 | 4.50 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 8759.83 | 0.17 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 8758.67 | 1.33 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 8747.83 | 12.17 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 8756.00 | 4.00 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 8742.50 | 17.50 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 8754.33 | 5.67 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 8759.67 | 0.33 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 8759.67 | 0.33 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 8752.67 | 7.33 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 8751.33 | 8.67 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 3069.33 | 4148.00 | 1542.67 | 0.00 | 0.00 |
| G CORRIDOR | 2905.50 | 3395.67 | 2451.83 | 7.00 | 0.00 |
| M CORRIDOR | 1254.00 | 7420.33 | 85.67 | 0.00 | 0.00 |
| Min | 1254.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 8760.00 | 7420.33 | 2451.83 | 7.00 | 0.00 |
| Average | 7897.68 | 668.93 | 193.14 | 0.26 | 0.00 |
| Sum | 213237.33 | 18061.00 | 5214.67 | 7.00 | 0.00 |
| Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| G SW APARTMENT | 11828.00 | 2.00 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 10584.67 | 0.33 | 0.00 | 0.00 | 0.00 |
| OFFICE | 7000.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 10584.67 | 0.33 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 11828.33 | 1.67 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 11824.00 | 6.00 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 11829.17 | 0.83 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 10585.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 11830.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 11822.50 | 7.50 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 10581.67 | 3.33 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 11823.50 | 6.50 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 10584.33 | 0.67 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 10584.50 | 0.50 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 10584.50 | 0.50 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 11826.33 | 3.67 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 11825.50 | 4.50 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 8339.83 | 10984.00 | 3671.17 | 0.00 | 0.00 |
| G CORRIDOR | 7244.50 | 8685.50 | 7050.00 | 15.00 | 0.00 |
| M CORRIDOR | 3366.83 | 19391.67 | 236.50 | 0.00 | 0.00 |
| Min | 3366.83 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 11830.00 | 19391.67 | 7050.00 | 15.00 | 0.00 |
| Average | 10483.81 | 1448.13 | 405.84 | 0.56 | 0.00 |
| Sum | 283062.83 | 39099.50 | 10957.67 | 15.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| G SW APARTMENT | 8575.17 | 184.83 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 8587.00 | 173.00 | 0.00 | 0.00 | 0.00 |
| OFFICE | 4573.17 | 3611.00 | 575.83 | 0.00 | 0.00 |
| G NE APARTMENT | 8566.33 | 193.67 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 8407.50 | 352.50 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 8398.00 | 362.00 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 8404.67 | 355.33 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 8573.33 | 186.67 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 8220.17 | 539.83 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 8218.33 | 541.67 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 8199.83 | 560.17 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 8192.17 | 567.83 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 7930.17 | 829.83 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 7929.00 | 831.00 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 7970.83 | 789.17 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 7969.50 | 790.50 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 8088.83 | 671.17 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 8062.50 | 697.50 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 8059.83 | 700.17 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 8027.67 | 732.33 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 7916.67 | 843.33 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 7916.00 | 844.00 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 7936.83 | 823.17 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 7935.33 | 824.67 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 21.83 | 5698.17 | 3040.00 | 0.00 | 0.00 |
| G CORRIDOR | 2367.83 | 4263.67 | 2088.33 | 40.17 | 0.00 |
| M CORRIDOR | 0.00 | 6061.17 | 2698.83 | 0.00 | 0.00 |
| Min | 0.00 | 173.00 | 0.00 | 0.00 | 0.00 |
| Max | 8587.00 | 6061.17 | 3040.00 | 40.17 | 0.00 |
| Average | 7224.02 | 1223.27 | 311.22 | 1.49 | 0.00 |
| Sum | 195048.50 | 33028.33 | 8403.00 | 40.17 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| G SW APARTMENT | 11554.50 | 275.50 | 0.00 | 0.00 | 0.00 |
| G NW APARTMENT | 10382.67 | 202.33 | 0.00 | 0.00 | 0.00 |
| OFFICE | 6974.67 | 25.33 | 0.00 | 0.00 | 0.00 |
| G NE APARTMENT | 10376.17 | 208.83 | 0.00 | 0.00 | 0.00 |
| G N1 APARTMENT | 10075.50 | 509.50 | 0.00 | 0.00 | 0.00 |
| G N2 APARTMENT | 10059.50 | 525.50 | 0.00 | 0.00 | 0.00 |
| G S1 APARTMENT | 11240.00 | 590.00 | 0.00 | 0.00 | 0.00 |
| G S2 APARTMENT | 11561.83 | 268.17 | 0.00 | 0.00 | 0.00 |
| M SW APARTMENT | 10947.17 | 882.83 | 0.00 | 0.00 | 0.00 |
| M NW APARTMENT | 9824.83 | 760.17 | 0.00 | 0.00 | 0.00 |
| M SE APARTMENT | 10916.17 | 913.83 | 0.00 | 0.00 | 0.00 |
| M NE APARTMENT | 9797.50 | 787.50 | 0.00 | 0.00 | 0.00 |
| M N1 APARTMENT | 9438.17 | 1146.83 | 0.00 | 0.00 | 0.00 |
| M N2 APARTMENT | 9436.17 | 1148.83 | 0.00 | 0.00 | 0.00 |
| M S1 APARTMENT | 10571.67 | 1258.33 | 0.00 | 0.00 | 0.00 |
| M S2 APARTMENT | 10568.83 | 1261.17 | 0.00 | 0.00 | 0.00 |
| T SW APARTMENT | 10755.17 | 1074.83 | 0.00 | 0.00 | 0.00 |
| T NW APARTMENT | 9601.33 | 983.67 | 0.00 | 0.00 | 0.00 |
| T SE APARTMENT | 10711.17 | 1118.83 | 0.00 | 0.00 | 0.00 |
| T NE APARTMENT | 9559.50 | 1025.50 | 0.00 | 0.00 | 0.00 |
| T N1 APARTMENT | 9395.67 | 1189.33 | 0.00 | 0.00 | 0.00 |
| T N2 APARTMENT | 9393.67 | 1191.33 | 0.00 | 0.00 | 0.00 |
| T S1 APARTMENT | 10518.33 | 1311.67 | 0.00 | 0.00 | 0.00 |
| T S2 APARTMENT | 10516.83 | 1313.17 | 0.00 | 0.00 | 0.00 |
| T CORRIDOR | 51.33 | 15212.83 | 7730.83 | 0.00 | 0.00 |
| G CORRIDOR | 5054.33 | 11578.33 | 6215.50 | 146.83 | 0.00 |
| M CORRIDOR | 0.00 | 16374.33 | 6620.67 | 0.00 | 0.00 |
| Min | 0.00 | 25.33 | 0.00 | 0.00 | 0.00 |
| Max | 11561.83 | 16374.33 | 7730.83 | 146.83 | 0.00 |
| Average | 9232.69 | 2338.46 | 761.74 | 5.44 | 0.00 |
| Sum | 249282.67 | 63138.50 | 20567.00 | 146.83 | 0.00 |
| SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
| None |
| SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
| None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
CO2 Level Hours| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2024-07-03 12:21:22
Illuminance Level Hours| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 1B
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.392 |
| February | 16.974 |
| March | 22.368 |
| April | 29.134 |
| May | 32.978 |
| June | 33.595 |
| July | 31.671 |
| August | 30.033 |
| September | 28.750 |
| October | 25.087 |
| November | 19.629 |
| December | 14.516 |
| Annual Sum or Average | 24.876 |
| Minimum of Months | 13.392 |
| Maximum of Months | 33.595 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.392 |
| February | 16.974 |
| March | 22.368 |
| April | 29.134 |
| May | 32.978 |
| June | 33.595 |
| July | 31.671 |
| August | 30.033 |
| September | 28.750 |
| October | 25.087 |
| November | 19.629 |
| December | 14.516 |
| Annual Sum or Average | 24.876 |
| Minimum of Months | 13.392 |
| Maximum of Months | 33.595 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.392 |
| February | 16.974 |
| March | 22.368 |
| April | 29.134 |
| May | 32.978 |
| June | 33.595 |
| July | 31.671 |
| August | 30.033 |
| September | 28.750 |
| October | 25.087 |
| November | 19.629 |
| December | 14.516 |
| Annual Sum or Average | 24.876 |
| Minimum of Months | 13.392 |
| Maximum of Months | 33.595 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2019
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.392 |
| February | 16.974 |
| March | 22.368 |
| April | 29.134 |
| May | 32.978 |
| June | 33.595 |
| July | 31.671 |
| August | 30.033 |
| September | 28.750 |
| October | 25.087 |
| November | 19.629 |
| December | 14.516 |
| Annual Sum or Average | 24.876 |
| Minimum of Months | 13.392 |
| Maximum of Months | 33.595 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.392 |
| February | 16.974 |
| March | 22.368 |
| April | 29.134 |
| May | 32.978 |
| June | 33.595 |
| July | 31.671 |
| August | 30.033 |
| September | 28.750 |
| October | 25.087 |
| November | 19.629 |
| December | 14.516 |
| Annual Sum or Average | 24.876 |
| Minimum of Months | 13.392 |
| Maximum of Months | 33.595 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY IND_DELHI_NEWDELHI
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.392 |
| February | 16.974 |
| March | 22.368 |
| April | 29.134 |
| May | 32.978 |
| June | 33.595 |
| July | 31.671 |
| August | 30.033 |
| September | 28.750 |
| October | 25.087 |
| November | 19.629 |
| December | 14.516 |
| Annual Sum or Average | 24.876 |
| Minimum of Months | 13.392 |
| Maximum of Months | 33.595 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.392 |
| February | 16.974 |
| March | 22.368 |
| April | 29.134 |
| May | 32.978 |
| June | 33.595 |
| July | 31.671 |
| August | 30.033 |
| September | 28.750 |
| October | 25.087 |
| November | 19.629 |
| December | 14.516 |
| Annual Sum or Average | 24.876 |
| Minimum of Months | 13.392 |
| Maximum of Months | 33.595 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PERFORMANCEPATHPROPOSED
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.392 |
| February | 16.974 |
| March | 22.368 |
| April | 29.134 |
| May | 32.978 |
| June | 33.595 |
| July | 31.671 |
| August | 30.033 |
| September | 28.750 |
| October | 25.087 |
| November | 19.629 |
| December | 14.516 |
| Annual Sum or Average | 24.876 |
| Minimum of Months | 13.392 |
| Maximum of Months | 33.595 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
| January | 13.392 |
| February | 16.974 |
| March | 22.368 |
| April | 29.134 |
| May | 32.978 |
| June | 33.595 |
| July | 31.671 |
| August | 30.033 |
| September | 28.750 |
| October | 25.087 |
| November | 19.629 |
| December | 14.516 |
| Annual Sum or Average | 24.876 |
| Minimum of Months | 13.392 |
| Maximum of Months | 33.595 |
Report: ZoneCoolingSummaryMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.611274E+09 | 5796.21 | 07-JAN-19:02 | 13.68 | 11.36 | 0.128828E+09 | 97.37 | 13-JAN-18:10 | 19.15 | 14.27 |
| February | 0.881341E+09 | 5794.92 | 27-FEB-13:52 | 21.70 | 13.76 | 0.121024E+09 | 102.92 | 20-FEB-18:19 | 21.70 | 13.76 |
| March | 0.184332E+10 | 5774.58 | 19-MAR-19:42 | 21.12 | 14.60 | 0.129727E+09 | 98.19 | 15-MAR-18:00 | 21.12 | 14.60 |
| April | 0.299260E+10 | 5753.64 | 09-APR-20:52 | 21.70 | 14.20 | 0.125890E+09 | 94.00 | 09-APR-20:40 | 21.70 | 14.20 |
| May | 0.379781E+10 | 4232.02 | 13-MAY-07:52 | 24.60 | 19.68 | 0.125898E+09 | 91.41 | 13-MAY-07:00 | 24.60 | 19.68 |
| June | 0.395158E+10 | 4364.45 | 27-JUN-11:52 | 24.50 | 23.35 | 0.120529E+09 | 92.43 | 18-JUN-06:00 | 24.50 | 23.35 |
| July | 0.413664E+10 | 2657.33 | 02-JUL-17:02 | 40.18 | 26.57 | 0.129276E+09 | 70.27 | 19-JUL-06:00 | 28.20 | 25.36 |
| August | 0.407107E+10 | 2492.98 | 06-AUG-16:40 | 36.10 | 26.38 | 0.123963E+09 | 70.27 | 12-AUG-07:49 | 28.98 | 28.69 |
| September | 0.387929E+10 | 4806.21 | 29-SEP-06:22 | 24.65 | 21.40 | 0.124174E+09 | 97.18 | 27-SEP-06:00 | 24.65 | 21.40 |
| October | 0.353858E+10 | 5805.69 | 24-OCT-20:52 | 21.60 | 16.34 | 0.134575E+09 | 101.69 | 11-OCT-20:10 | 21.60 | 16.34 |
| November | 0.229589E+10 | 5844.32 | 26-NOV-21:32 | 14.60 | 11.35 | 0.134745E+09 | 107.46 | 26-NOV-16:19 | 14.60 | 11.35 |
| December | 0.110888E+10 | 5875.47 | 08-DEC-17:01 | 18.15 | 13.70 | 0.135076E+09 | 102.71 | 02-DEC-17:40 | 18.15 | 13.70 |
| Annual Sum or Average | 0.331083E+11 | 0.153370E+10 | ||||||||
| Minimum of Months | 0.611274E+09 | 2492.98 | 13.68 | 11.35 | 0.120529E+09 | 70.27 | 14.60 | 11.35 | ||
| Maximum of Months | 0.413664E+10 | 5875.47 | 40.18 | 26.57 | 0.135076E+09 | 107.46 | 28.98 | 28.69 |
Report: ZoneCoolingSummaryMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.220597E+09 | 4177.57 | 14-JAN-22:52 | 17.30 | 13.73 | 0.111860E+09 | 78.10 | 14-JAN-22:00 | 17.30 | 13.73 |
| February | 0.341593E+09 | 5705.54 | 21-FEB-19:42 | 20.15 | 14.74 | 0.115240E+09 | 85.78 | 24-FEB-22:49 | 19.15 | 16.48 |
| March | 0.121561E+10 | 5694.35 | 21-MAR-17:02 | 22.78 | 14.79 | 0.133700E+09 | 90.43 | 30-MAR-20:10 | 22.28 | 17.63 |
| April | 0.256719E+10 | 5688.54 | 09-APR-21:12 | 21.47 | 14.17 | 0.126363E+09 | 92.22 | 09-APR-21:10 | 21.47 | 14.17 |
| May | 0.371422E+10 | 4242.12 | 13-MAY-07:52 | 24.60 | 19.68 | 0.128884E+09 | 85.02 | 13-MAY-05:00 | 24.60 | 19.68 |
| June | 0.397636E+10 | 4300.77 | 27-JUN-11:52 | 24.50 | 23.35 | 0.124730E+09 | 85.94 | 18-JUN-05:40 | 24.50 | 23.35 |
| July | 0.414234E+10 | 2659.04 | 02-JUL-17:17 | 40.07 | 26.58 | 0.128775E+09 | 70.27 | 25-JUL-05:40 | 28.20 | 26.15 |
| August | 0.399648E+10 | 2427.02 | 07-AUG-17:02 | 36.48 | 26.95 | 0.128775E+09 | 70.27 | 12-AUG-05:49 | 27.95 | 27.04 |
| September | 0.352134E+10 | 4707.58 | 29-SEP-06:22 | 24.65 | 21.40 | 0.124810E+09 | 87.86 | 29-SEP-05:49 | 24.65 | 21.40 |
| October | 0.265147E+10 | 5601.76 | 24-OCT-21:42 | 21.18 | 16.67 | 0.135215E+09 | 99.64 | 11-OCT-20:10 | 21.18 | 16.67 |
| November | 0.127296E+10 | 5753.04 | 23-NOV-21:12 | 14.50 | 11.83 | 0.134803E+09 | 95.94 | 01-NOV-20:10 | 14.50 | 11.83 |
| December | 0.364920E+09 | 5744.03 | 04-DEC-20:02 | 13.90 | 11.82 | 0.130130E+09 | 88.74 | 28-DEC-21:10 | 18.85 | 14.08 |
| Annual Sum or Average | 0.279851E+11 | 0.152329E+10 | ||||||||
| Minimum of Months | 0.220597E+09 | 2427.02 | 13.90 | 11.82 | 0.111860E+09 | 70.27 | 14.50 | 11.83 | ||
| Maximum of Months | 0.414234E+10 | 5753.04 | 40.07 | 26.95 | 0.135215E+09 | 99.64 | 28.20 | 27.04 |
Report: ZoneCoolingSummaryMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.802979E+09 | 3178.02 | 26-JAN-07:01 | 12.98 | 11.90 | 66400939.93 | 133.52 | 26-JAN-10:20 | 18.10 | 12.94 |
| February | 0.948634E+09 | 6874.73 | 21-FEB-07:01 | 12.08 | 11.15 | 63849372.02 | 133.53 | 23-FEB-09:50 | 20.57 | 14.30 |
| March | 0.157757E+10 | 6854.15 | 16-MAR-06:01 | 14.97 | 12.11 | 77383701.17 | 133.53 | 29-MAR-10:39 | 28.00 | 19.68 |
| April | 0.205706E+10 | 6950.59 | 04-APR-06:01 | 23.23 | 15.86 | 67291524.21 | 133.54 | 18-APR-08:39 | 28.33 | 21.04 |
| May | 0.270794E+10 | 6744.15 | 05-MAY-06:01 | 30.43 | 17.14 | 74022988.32 | 133.54 | 22-MAY-07:40 | 31.13 | 25.22 |
| June | 0.275666E+10 | 6496.18 | 05-JUN-06:01 | 31.05 | 20.86 | 74023764.98 | 133.57 | 27-JUN-07:10 | 29.57 | 26.81 |
| July | 0.260741E+10 | 4998.72 | 05-JUL-06:01 | 33.02 | 24.50 | 67294135.72 | 133.71 | 18-JUL-07:10 | 29.05 | 27.65 |
| August | 0.287857E+10 | 4826.01 | 03-AUG-06:01 | 28.43 | 23.36 | 77391172.65 | 134.11 | 28-AUG-07:10 | 29.38 | 27.16 |
| September | 0.254428E+10 | 5389.02 | 26-SEP-06:01 | 25.28 | 20.15 | 67294602.39 | 133.61 | 18-SEP-07:10 | 25.28 | 20.15 |
| October | 0.255783E+10 | 7073.19 | 23-OCT-06:01 | 19.08 | 14.21 | 70657207.03 | 133.54 | 02-OCT-07:10 | 19.08 | 14.21 |
| November | 0.184969E+10 | 7111.56 | 27-NOV-07:01 | 10.02 | 9.28 | 67290573.46 | 133.53 | 07-NOV-09:20 | 10.02 | 9.28 |
| December | 0.117573E+10 | 6874.06 | 01-DEC-07:01 | 12.92 | 9.54 | 67268939.26 | 133.52 | 29-DEC-16:49 | 18.40 | 15.07 |
| Annual Sum or Average | 0.244644E+11 | 0.840169E+09 | ||||||||
| Minimum of Months | 0.802979E+09 | 3178.02 | 10.02 | 9.28 | 63849372.02 | 133.52 | 10.02 | 9.28 | ||
| Maximum of Months | 0.287857E+10 | 7111.56 | 33.02 | 24.50 | 77391172.65 | 134.11 | 31.13 | 27.65 |
Report: ZoneCoolingSummaryMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.220946E+09 | 3924.00 | 14-JAN-22:52 | 17.30 | 13.73 | 0.111789E+09 | 77.58 | 14-JAN-22:00 | 17.30 | 13.73 |
| February | 0.346192E+09 | 5520.31 | 28-FEB-19:12 | 21.00 | 14.89 | 0.115665E+09 | 86.66 | 24-FEB-22:49 | 21.00 | 14.89 |
| March | 0.121158E+10 | 5523.07 | 04-MAR-19:42 | 21.68 | 15.86 | 0.133975E+09 | 90.45 | 30-MAR-20:10 | 22.28 | 17.63 |
| April | 0.258311E+10 | 5508.68 | 09-APR-21:12 | 21.47 | 14.17 | 0.126442E+09 | 91.34 | 09-APR-21:10 | 21.47 | 14.17 |
| May | 0.374111E+10 | 4107.25 | 13-MAY-07:52 | 24.60 | 19.68 | 0.128884E+09 | 84.94 | 13-MAY-05:00 | 24.60 | 19.68 |
| June | 0.392884E+10 | 4163.44 | 27-JUN-11:52 | 24.50 | 23.35 | 0.124728E+09 | 85.64 | 18-JUN-05:40 | 24.50 | 23.35 |
| July | 0.414796E+10 | 2402.62 | 07-JUL-17:02 | 39.22 | 25.12 | 0.128775E+09 | 70.27 | 20-JUL-01:00 | 29.10 | 26.67 |
| August | 0.400227E+10 | 2240.72 | 07-AUG-17:02 | 36.48 | 26.95 | 0.128775E+09 | 70.27 | 20-AUG-05:49 | 26.32 | 25.93 |
| September | 0.350849E+10 | 4555.19 | 29-SEP-06:22 | 24.65 | 21.40 | 0.124807E+09 | 87.67 | 29-SEP-05:49 | 24.65 | 21.40 |
| October | 0.266430E+10 | 5431.62 | 24-OCT-21:42 | 21.18 | 16.67 | 0.135296E+09 | 99.75 | 11-OCT-20:10 | 21.18 | 16.67 |
| November | 0.126352E+10 | 5574.98 | 23-NOV-21:12 | 14.50 | 11.83 | 0.134787E+09 | 95.35 | 01-NOV-20:10 | 14.50 | 11.83 |
| December | 0.360971E+09 | 5565.64 | 01-DEC-20:12 | 13.37 | 12.16 | 0.129830E+09 | 87.80 | 28-DEC-21:10 | 18.85 | 14.08 |
| Annual Sum or Average | 0.279793E+11 | 0.152375E+10 | ||||||||
| Minimum of Months | 0.220946E+09 | 2240.72 | 13.37 | 11.83 | 0.111789E+09 | 70.27 | 14.50 | 11.83 | ||
| Maximum of Months | 0.414796E+10 | 5574.98 | 39.22 | 26.95 | 0.135296E+09 | 99.75 | 29.10 | 26.67 |
Report: ZoneCoolingSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.283858E+09 | 4920.18 | 26-JAN-20:42 | 14.92 | 11.74 | 0.120008E+09 | 81.41 | 14-JAN-22:00 | 14.92 | 11.74 |
| February | 0.414037E+09 | 4926.82 | 28-FEB-19:12 | 21.00 | 14.89 | 0.119560E+09 | 87.53 | 24-FEB-22:49 | 21.00 | 14.89 |
| March | 0.114034E+10 | 4924.15 | 04-MAR-19:42 | 21.68 | 15.86 | 0.134256E+09 | 90.56 | 30-MAR-20:10 | 22.28 | 17.63 |
| April | 0.209612E+10 | 4908.34 | 09-APR-21:12 | 21.47 | 14.17 | 0.126489E+09 | 90.97 | 09-APR-21:10 | 21.47 | 14.17 |
| May | 0.295207E+10 | 3661.80 | 13-MAY-07:52 | 24.60 | 19.68 | 0.128884E+09 | 85.11 | 13-MAY-05:00 | 24.60 | 19.68 |
| June | 0.313605E+10 | 3659.96 | 27-JUN-11:52 | 24.50 | 23.35 | 0.124726E+09 | 85.02 | 18-JUN-05:40 | 24.50 | 23.35 |
| July | 0.333203E+10 | 1852.41 | 04-JUL-17:30 | 40.05 | 24.21 | 0.128775E+09 | 70.27 | 16-JUL-05:19 | 28.90 | 26.62 |
| August | 0.322972E+10 | 1730.33 | 07-AUG-17:12 | 36.37 | 26.97 | 0.128775E+09 | 70.27 | 29-AUG-21:30 | 28.85 | 27.95 |
| September | 0.284740E+10 | 3989.37 | 29-SEP-06:22 | 24.65 | 21.40 | 0.124794E+09 | 86.25 | 29-SEP-05:49 | 24.65 | 21.40 |
| October | 0.220618E+10 | 4849.38 | 24-OCT-21:42 | 21.18 | 16.67 | 0.134980E+09 | 98.46 | 11-OCT-20:10 | 21.18 | 16.67 |
| November | 0.120002E+10 | 4986.37 | 23-NOV-21:12 | 14.50 | 11.83 | 0.134463E+09 | 93.97 | 01-NOV-20:10 | 14.50 | 11.83 |
| December | 0.517728E+09 | 4978.39 | 01-DEC-20:12 | 13.37 | 12.16 | 0.132556E+09 | 89.29 | 28-DEC-21:10 | 18.85 | 14.08 |
| Annual Sum or Average | 0.233556E+11 | 0.153827E+10 | ||||||||
| Minimum of Months | 0.283858E+09 | 1730.33 | 13.37 | 11.74 | 0.119560E+09 | 70.27 | 14.50 | 11.74 | ||
| Maximum of Months | 0.333203E+10 | 4986.37 | 40.05 | 26.97 | 0.134980E+09 | 98.46 | 28.90 | 27.95 |
Report: ZoneCoolingSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.284324E+09 | 4920.37 | 27-JAN-19:02 | 14.27 | 11.17 | 0.120061E+09 | 81.40 | 14-JAN-22:00 | 14.27 | 11.17 |
| February | 0.417241E+09 | 4924.09 | 28-FEB-19:12 | 21.00 | 14.89 | 0.119637E+09 | 87.65 | 24-FEB-22:49 | 21.00 | 14.89 |
| March | 0.114411E+10 | 4921.88 | 04-MAR-19:42 | 21.68 | 15.86 | 0.134274E+09 | 90.58 | 30-MAR-20:10 | 22.28 | 17.63 |
| April | 0.209794E+10 | 4905.71 | 09-APR-21:12 | 21.47 | 14.17 | 0.126490E+09 | 90.95 | 09-APR-21:10 | 21.47 | 14.17 |
| May | 0.295327E+10 | 3663.05 | 13-MAY-07:52 | 24.60 | 19.68 | 0.128884E+09 | 85.10 | 13-MAY-05:00 | 24.60 | 19.68 |
| June | 0.313448E+10 | 3659.82 | 27-JUN-11:52 | 24.50 | 23.35 | 0.124726E+09 | 85.01 | 18-JUN-05:40 | 24.50 | 23.35 |
| July | 0.333227E+10 | 1848.91 | 04-JUL-17:30 | 40.05 | 24.21 | 0.128775E+09 | 70.27 | 17-JUL-05:10 | 30.12 | 26.54 |
| August | 0.323003E+10 | 1727.85 | 07-AUG-17:12 | 36.37 | 26.97 | 0.128775E+09 | 70.27 | 29-AUG-21:19 | 28.83 | 27.96 |
| September | 0.284702E+10 | 3989.62 | 29-SEP-06:22 | 24.65 | 21.40 | 0.124794E+09 | 86.24 | 29-SEP-05:49 | 24.65 | 21.40 |
| October | 0.220797E+10 | 4850.96 | 24-OCT-21:42 | 21.18 | 16.67 | 0.134982E+09 | 98.47 | 11-OCT-20:10 | 21.18 | 16.67 |
| November | 0.120227E+10 | 4983.82 | 23-NOV-21:12 | 14.50 | 11.83 | 0.134473E+09 | 93.97 | 01-NOV-20:10 | 14.50 | 11.83 |
| December | 0.518313E+09 | 4975.90 | 01-DEC-20:12 | 13.37 | 12.16 | 0.132573E+09 | 89.30 | 28-DEC-21:10 | 18.85 | 14.08 |
| Annual Sum or Average | 0.233692E+11 | 0.153844E+10 | ||||||||
| Minimum of Months | 0.284324E+09 | 1727.85 | 13.37 | 11.17 | 0.119637E+09 | 70.27 | 14.27 | 11.17 | ||
| Maximum of Months | 0.333227E+10 | 4983.82 | 40.05 | 26.97 | 0.134982E+09 | 98.47 | 30.12 | 27.96 |
Report: ZoneCoolingSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.893368E+09 | 5081.16 | 07-JAN-19:02 | 13.68 | 11.36 | 0.132822E+09 | 96.69 | 13-JAN-18:10 | 19.15 | 14.27 |
| February | 0.107887E+10 | 5069.82 | 06-FEB-21:32 | 14.47 | 12.08 | 0.122716E+09 | 100.35 | 18-FEB-17:30 | 22.90 | 13.43 |
| March | 0.180496E+10 | 5030.60 | 19-MAR-19:42 | 21.12 | 14.60 | 0.130340E+09 | 95.51 | 15-MAR-18:00 | 21.12 | 14.60 |
| April | 0.254129E+10 | 5013.47 | 09-APR-20:52 | 21.70 | 14.20 | 0.126050E+09 | 92.98 | 09-APR-20:40 | 21.70 | 14.20 |
| May | 0.304997E+10 | 3687.98 | 13-MAY-07:52 | 24.60 | 19.68 | 0.125898E+09 | 91.19 | 13-MAY-07:00 | 24.60 | 19.68 |
| June | 0.312283E+10 | 3750.10 | 27-JUN-11:52 | 24.50 | 23.35 | 0.120525E+09 | 92.42 | 18-JUN-06:00 | 24.50 | 23.35 |
| July | 0.333914E+10 | 1841.73 | 04-JUL-17:17 | 40.00 | 24.23 | 0.129276E+09 | 70.27 | 01-JUL-15:20 | 40.00 | 24.23 |
| August | 0.331752E+10 | 1780.89 | 07-AUG-17:12 | 36.37 | 26.97 | 0.123963E+09 | 70.27 | 20-AUG-05:19 | 26.37 | 25.98 |
| September | 0.322222E+10 | 4135.87 | 29-SEP-06:22 | 24.65 | 21.40 | 0.124160E+09 | 95.72 | 27-SEP-06:00 | 24.65 | 21.40 |
| October | 0.311579E+10 | 5044.87 | 24-OCT-20:52 | 21.60 | 16.34 | 0.134511E+09 | 100.71 | 11-OCT-20:10 | 21.60 | 16.34 |
| November | 0.225789E+10 | 5110.74 | 26-NOV-21:32 | 14.60 | 11.35 | 0.134815E+09 | 104.67 | 26-NOV-16:19 | 14.60 | 11.35 |
| December | 0.138832E+10 | 5117.27 | 09-DEC-19:12 | 13.63 | 11.72 | 0.136033E+09 | 100.51 | 02-DEC-17:40 | 13.63 | 11.72 |
| Annual Sum or Average | 0.291322E+11 | 0.154111E+10 | ||||||||
| Minimum of Months | 0.893368E+09 | 1780.89 | 13.63 | 11.35 | 0.120525E+09 | 70.27 | 13.63 | 11.35 | ||
| Maximum of Months | 0.333914E+10 | 5117.27 | 40.00 | 26.97 | 0.136033E+09 | 104.67 | 40.00 | 25.98 |
Report: ZoneCoolingSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.881393E+09 | 5118.74 | 07-JAN-19:02 | 13.68 | 11.36 | 0.132554E+09 | 96.57 | 13-JAN-18:10 | 19.15 | 14.27 |
| February | 0.110526E+10 | 5110.78 | 06-FEB-21:32 | 14.47 | 12.08 | 0.122906E+09 | 100.85 | 18-FEB-17:30 | 22.90 | 13.43 |
| March | 0.191616E+10 | 5075.17 | 19-MAR-19:42 | 21.12 | 14.60 | 0.130724E+09 | 96.54 | 15-MAR-18:00 | 21.12 | 14.60 |
| April | 0.277729E+10 | 5064.47 | 09-APR-21:52 | 21.00 | 14.09 | 0.126272E+09 | 95.13 | 09-APR-20:40 | 21.00 | 14.09 |
| May | 0.334620E+10 | 3797.30 | 13-MAY-07:52 | 24.60 | 19.68 | 0.125913E+09 | 92.43 | 13-MAY-07:00 | 24.60 | 19.68 |
| June | 0.340708E+10 | 3858.19 | 27-JUN-11:52 | 24.50 | 23.35 | 0.120535E+09 | 92.99 | 18-JUN-06:40 | 24.50 | 23.35 |
| July | 0.365463E+10 | 1994.37 | 04-JUL-17:17 | 40.00 | 24.23 | 0.129276E+09 | 70.27 | 19-JUL-00:49 | 25.05 | 25.03 |
| August | 0.361591E+10 | 1935.41 | 06-AUG-16:40 | 36.10 | 26.38 | 0.123963E+09 | 70.27 | 26-AUG-05:10 | 26.08 | 25.65 |
| September | 0.351160E+10 | 4219.92 | 29-SEP-06:22 | 24.65 | 21.40 | 0.124176E+09 | 97.50 | 27-SEP-06:00 | 24.65 | 21.40 |
| October | 0.335184E+10 | 5095.50 | 24-OCT-20:52 | 21.60 | 16.34 | 0.135156E+09 | 102.20 | 11-OCT-20:10 | 21.60 | 16.34 |
| November | 0.238431E+10 | 5139.08 | 21-NOV-21:42 | 14.82 | 12.74 | 0.135401E+09 | 105.89 | 26-NOV-16:19 | 22.53 | 14.49 |
| December | 0.140663E+10 | 5157.32 | 09-DEC-19:12 | 13.63 | 11.72 | 0.136082E+09 | 100.90 | 02-DEC-17:40 | 13.63 | 11.72 |
| Annual Sum or Average | 0.313583E+11 | 0.154296E+10 | ||||||||
| Minimum of Months | 0.881393E+09 | 1935.41 | 13.63 | 11.36 | 0.120535E+09 | 70.27 | 13.63 | 11.72 | ||
| Maximum of Months | 0.365463E+10 | 5157.32 | 40.00 | 26.38 | 0.136082E+09 | 105.89 | 26.08 | 25.65 |
Report: ZoneCoolingSummaryMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.757164E+09 | 6371.61 | 07-JAN-19:02 | 13.68 | 11.36 | 0.130565E+09 | 99.75 | 08-JAN-16:40 | 21.07 | 14.07 |
| February | 0.122647E+10 | 6369.18 | 27-FEB-21:02 | 17.52 | 13.45 | 0.123634E+09 | 105.25 | 04-FEB-16:19 | 17.52 | 13.45 |
| March | 0.248131E+10 | 6330.10 | 19-MAR-19:42 | 21.12 | 14.60 | 0.131230E+09 | 100.85 | 15-MAR-18:00 | 21.12 | 14.60 |
| April | 0.362971E+10 | 6297.25 | 09-APR-21:52 | 21.00 | 14.09 | 0.126000E+09 | 94.93 | 09-APR-20:40 | 21.00 | 14.09 |
| May | 0.418343E+10 | 4584.27 | 13-MAY-07:52 | 24.60 | 19.68 | 0.125888E+09 | 90.64 | 13-MAY-07:00 | 24.60 | 19.68 |
| June | 0.401152E+10 | 4681.86 | 27-JUN-11:52 | 24.50 | 23.35 | 0.120512E+09 | 90.14 | 18-JUN-06:00 | 24.50 | 23.35 |
| July | 0.382473E+10 | 2692.13 | 02-JUL-16:50 | 40.32 | 26.53 | 0.129276E+09 | 70.27 | 16-JUL-07:49 | 30.25 | 26.80 |
| August | 0.353968E+10 | 2420.46 | 06-AUG-16:30 | 36.15 | 26.34 | 0.123963E+09 | 70.27 | 12-AUG-08:50 | 29.85 | 28.86 |
| September | 0.334237E+10 | 4976.68 | 29-SEP-06:22 | 24.65 | 21.40 | 0.124114E+09 | 89.81 | 27-SEP-06:00 | 24.65 | 21.40 |
| October | 0.318551E+10 | 6323.64 | 24-OCT-20:52 | 21.60 | 16.34 | 0.132789E+09 | 95.94 | 11-OCT-20:10 | 21.60 | 16.34 |
| November | 0.213614E+10 | 6383.01 | 28-NOV-15:32 | 22.83 | 15.37 | 0.133490E+09 | 105.87 | 26-NOV-16:19 | 22.83 | 15.37 |
| December | 0.105239E+10 | 6443.05 | 08-DEC-17:01 | 18.15 | 13.70 | 0.134563E+09 | 103.06 | 02-DEC-16:40 | 18.15 | 13.70 |
| Annual Sum or Average | 0.333704E+11 | 0.153602E+10 | ||||||||
| Minimum of Months | 0.757164E+09 | 2420.46 | 13.68 | 11.36 | 0.120512E+09 | 70.27 | 17.52 | 13.45 | ||
| Maximum of Months | 0.418343E+10 | 6443.05 | 40.32 | 26.53 | 0.134563E+09 | 105.87 | 30.25 | 28.86 |
Report: ZoneCoolingSummaryMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.250827E+09 | 5748.94 | 14-JAN-22:52 | 17.30 | 13.73 | 0.115354E+09 | 82.55 | 14-JAN-22:49 | 17.30 | 13.73 |
| February | 0.560140E+09 | 6267.84 | 21-FEB-19:42 | 20.15 | 14.74 | 0.121168E+09 | 92.09 | 25-FEB-21:10 | 17.88 | 15.63 |
| March | 0.179753E+10 | 6275.04 | 21-MAR-21:22 | 20.40 | 14.12 | 0.135844E+09 | 93.81 | 24-MAR-20:19 | 22.27 | 13.59 |
| April | 0.317217E+10 | 6234.70 | 09-APR-21:12 | 21.47 | 14.17 | 0.126523E+09 | 93.16 | 09-APR-20:49 | 21.47 | 14.17 |
| May | 0.408829E+10 | 4593.17 | 13-MAY-07:52 | 24.60 | 19.68 | 0.128877E+09 | 84.01 | 13-MAY-05:00 | 24.60 | 19.68 |
| June | 0.402646E+10 | 4619.48 | 27-JUN-11:52 | 24.50 | 23.35 | 0.124713E+09 | 83.06 | 18-JUN-05:40 | 24.50 | 23.35 |
| July | 0.381801E+10 | 2662.56 | 02-JUL-17:17 | 40.07 | 26.58 | 0.128775E+09 | 70.27 | 24-JUL-23:40 | 28.50 | 26.29 |
| August | 0.344963E+10 | 2307.97 | 07-AUG-16:20 | 36.93 | 26.75 | 0.128775E+09 | 70.27 | 30-AUG-01:10 | 28.78 | 27.65 |
| September | 0.295596E+10 | 4852.03 | 29-SEP-06:22 | 24.65 | 21.40 | 0.124756E+09 | 82.69 | 29-SEP-05:49 | 24.65 | 21.40 |
| October | 0.225420E+10 | 6131.33 | 24-OCT-21:42 | 21.18 | 16.67 | 0.133478E+09 | 94.69 | 11-OCT-20:10 | 21.18 | 16.67 |
| November | 0.106143E+10 | 6277.70 | 23-NOV-21:12 | 14.50 | 11.83 | 0.132685E+09 | 91.09 | 01-NOV-20:10 | 14.50 | 11.83 |
| December | 0.311043E+09 | 6265.84 | 01-DEC-20:12 | 13.37 | 12.16 | 0.126422E+09 | 87.83 | 28-DEC-21:10 | 18.85 | 14.08 |
| Annual Sum or Average | 0.277457E+11 | 0.152737E+10 | ||||||||
| Minimum of Months | 0.250827E+09 | 2307.97 | 13.37 | 11.83 | 0.115354E+09 | 70.27 | 14.50 | 11.83 | ||
| Maximum of Months | 0.408829E+10 | 6277.70 | 40.07 | 26.75 | 0.135844E+09 | 94.69 | 28.78 | 27.65 |
Report: ZoneCoolingSummaryMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.772991E+09 | 6154.32 | 07-JAN-19:02 | 13.68 | 11.36 | 0.130299E+09 | 97.87 | 12-JAN-18:49 | 18.87 | 13.42 |
| February | 0.125029E+10 | 6152.87 | 27-FEB-13:52 | 21.70 | 13.76 | 0.123626E+09 | 103.51 | 18-FEB-17:30 | 21.70 | 13.76 |
| March | 0.249079E+10 | 6127.22 | 02-MAR-12:32 | 24.50 | 15.69 | 0.131400E+09 | 100.24 | 05-MAR-10:20 | 23.60 | 15.88 |
| April | 0.364911E+10 | 6085.33 | 09-APR-21:52 | 21.00 | 14.09 | 0.126048E+09 | 94.30 | 23-APR-08:30 | 25.15 | 18.36 |
| May | 0.421301E+10 | 4439.31 | 13-MAY-07:52 | 24.60 | 19.68 | 0.125888E+09 | 91.09 | 13-MAY-07:00 | 24.60 | 19.68 |
| June | 0.396033E+10 | 4522.64 | 27-JUN-11:52 | 24.50 | 23.35 | 0.120511E+09 | 89.82 | 18-JUN-06:00 | 24.50 | 23.35 |
| July | 0.383059E+10 | 2295.99 | 02-JUL-16:30 | 40.35 | 26.46 | 0.129276E+09 | 70.27 | 21-JUL-05:49 | 28.62 | 25.81 |
| August | 0.354581E+10 | 2169.16 | 07-AUG-16:01 | 37.02 | 26.70 | 0.123963E+09 | 70.27 | 28-AUG-00:49 | 30.05 | 27.57 |
| September | 0.332948E+10 | 4796.24 | 29-SEP-06:22 | 24.65 | 21.40 | 0.124112E+09 | 90.06 | 27-SEP-06:00 | 24.65 | 21.40 |
| October | 0.320438E+10 | 6108.20 | 24-OCT-20:52 | 21.60 | 16.34 | 0.132871E+09 | 97.37 | 28-OCT-09:39 | 23.80 | 17.06 |
| November | 0.213195E+10 | 6167.25 | 26-NOV-21:32 | 14.60 | 11.35 | 0.133541E+09 | 104.04 | 26-NOV-16:19 | 14.60 | 11.35 |
| December | 0.106104E+10 | 6217.84 | 08-DEC-17:01 | 18.15 | 13.70 | 0.134554E+09 | 100.04 | 02-DEC-17:40 | 18.15 | 13.70 |
| Annual Sum or Average | 0.334398E+11 | 0.153609E+10 | ||||||||
| Minimum of Months | 0.772991E+09 | 2169.16 | 13.68 | 11.35 | 0.120511E+09 | 70.27 | 14.60 | 11.35 | ||
| Maximum of Months | 0.421301E+10 | 6217.84 | 40.35 | 26.70 | 0.134554E+09 | 104.04 | 30.05 | 27.57 |
Report: ZoneCoolingSummaryMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.250479E+09 | 5543.23 | 14-JAN-22:52 | 17.30 | 13.73 | 0.115303E+09 | 81.91 | 14-JAN-22:49 | 17.30 | 13.73 |
| February | 0.569376E+09 | 6048.88 | 28-FEB-19:12 | 21.00 | 14.89 | 0.121287E+09 | 89.67 | 18-FEB-21:10 | 21.00 | 14.89 |
| March | 0.179735E+10 | 6056.23 | 19-MAR-20:12 | 20.57 | 14.42 | 0.136173E+09 | 94.17 | 21-MAR-21:10 | 20.53 | 14.18 |
| April | 0.319050E+10 | 6022.96 | 09-APR-21:12 | 21.47 | 14.17 | 0.126612E+09 | 92.43 | 09-APR-21:10 | 21.47 | 14.17 |
| May | 0.411798E+10 | 4441.35 | 13-MAY-07:52 | 24.60 | 19.68 | 0.128877E+09 | 83.88 | 13-MAY-05:00 | 24.60 | 19.68 |
| June | 0.397530E+10 | 4459.59 | 27-JUN-11:52 | 24.50 | 23.35 | 0.124712E+09 | 82.78 | 18-JUN-05:40 | 24.50 | 23.35 |
| July | 0.382389E+10 | 2304.96 | 07-JUL-16:17 | 39.87 | 24.83 | 0.128775E+09 | 70.27 | 26-JUL-02:49 | 27.68 | 24.83 |
| August | 0.345576E+10 | 2084.18 | 07-AUG-16:20 | 36.93 | 26.75 | 0.128775E+09 | 70.27 | 28-AUG-00:10 | 30.25 | 27.76 |
| September | 0.294303E+10 | 4671.48 | 29-SEP-06:22 | 24.65 | 21.40 | 0.124754E+09 | 82.49 | 29-SEP-05:49 | 24.65 | 21.40 |
| October | 0.226768E+10 | 5884.83 | 24-OCT-21:42 | 21.18 | 16.67 | 0.133567E+09 | 94.72 | 11-OCT-20:10 | 21.18 | 16.67 |
| November | 0.103937E+10 | 6056.19 | 01-NOV-20:22 | 20.00 | 15.16 | 0.132258E+09 | 90.39 | 01-NOV-20:10 | 20.00 | 15.16 |
| December | 0.302463E+09 | 6051.01 | 01-DEC-20:12 | 13.37 | 12.16 | 0.126190E+09 | 82.62 | 28-DEC-22:00 | 17.20 | 13.76 |
| Annual Sum or Average | 0.277332E+11 | 0.152728E+10 | ||||||||
| Minimum of Months | 0.250479E+09 | 2084.18 | 13.37 | 12.16 | 0.115303E+09 | 70.27 | 17.20 | 13.73 | ||
| Maximum of Months | 0.411798E+10 | 6056.23 | 39.87 | 26.75 | 0.136173E+09 | 94.72 | 30.25 | 27.76 |
Report: ZoneCoolingSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.360357E+09 | 5335.14 | 27-JAN-19:02 | 14.27 | 11.17 | 0.124483E+09 | 85.82 | 14-JAN-22:00 | 14.27 | 11.17 |
| February | 0.650283E+09 | 5338.74 | 06-FEB-21:32 | 14.47 | 12.08 | 0.122972E+09 | 89.70 | 24-FEB-22:49 | 19.15 | 16.48 |
| March | 0.154075E+10 | 5353.22 | 21-MAR-21:22 | 20.40 | 14.12 | 0.135651E+09 | 93.48 | 21-MAR-21:10 | 20.40 | 14.12 |
| April | 0.241660E+10 | 5301.73 | 09-APR-21:12 | 21.47 | 14.17 | 0.126516E+09 | 91.07 | 09-APR-21:10 | 21.47 | 14.17 |
| May | 0.307249E+10 | 3884.74 | 13-MAY-07:52 | 24.60 | 19.68 | 0.128874E+09 | 83.64 | 13-MAY-05:00 | 24.60 | 19.68 |
| June | 0.304291E+10 | 3862.68 | 27-JUN-11:52 | 24.50 | 23.35 | 0.124709E+09 | 82.40 | 18-JUN-05:49 | 24.50 | 23.35 |
| July | 0.301100E+10 | 1725.79 | 02-JUL-17:35 | 39.83 | 26.58 | 0.128775E+09 | 70.27 | 13-JUL-23:30 | 31.45 | 27.03 |
| August | 0.277747E+10 | 1563.48 | 07-AUG-17:12 | 36.37 | 26.97 | 0.128775E+09 | 70.27 | 25-AUG-23:30 | 26.35 | 25.96 |
| September | 0.239366E+10 | 4085.60 | 29-SEP-06:22 | 24.65 | 21.40 | 0.124751E+09 | 82.34 | 29-SEP-05:00 | 24.65 | 21.40 |
| October | 0.188405E+10 | 5158.68 | 24-OCT-21:42 | 21.18 | 16.67 | 0.133480E+09 | 94.22 | 11-OCT-20:10 | 21.18 | 16.67 |
| November | 0.103800E+10 | 5350.33 | 23-NOV-21:12 | 14.50 | 11.83 | 0.132017E+09 | 89.69 | 02-NOV-20:40 | 14.50 | 11.83 |
| December | 0.479402E+09 | 5368.01 | 01-DEC-20:12 | 13.37 | 12.16 | 0.131579E+09 | 85.91 | 28-DEC-22:00 | 17.20 | 13.76 |
| Annual Sum or Average | 0.226670E+11 | 0.154258E+10 | ||||||||
| Minimum of Months | 0.360357E+09 | 1563.48 | 13.37 | 11.17 | 0.122972E+09 | 70.27 | 14.27 | 11.17 | ||
| Maximum of Months | 0.307249E+10 | 5368.01 | 39.83 | 26.97 | 0.135651E+09 | 94.22 | 31.45 | 27.03 |
Report: ZoneCoolingSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.361323E+09 | 5332.12 | 27-JAN-19:02 | 14.27 | 11.17 | 0.124542E+09 | 85.81 | 14-JAN-22:00 | 14.27 | 11.17 |
| February | 0.654227E+09 | 5335.52 | 06-FEB-21:32 | 14.47 | 12.08 | 0.123023E+09 | 89.82 | 24-FEB-22:49 | 19.15 | 16.48 |
| March | 0.154574E+10 | 5348.85 | 21-MAR-21:22 | 20.40 | 14.12 | 0.135674E+09 | 93.61 | 21-MAR-21:10 | 20.40 | 14.12 |
| April | 0.241855E+10 | 5298.01 | 09-APR-21:12 | 21.47 | 14.17 | 0.126517E+09 | 91.04 | 09-APR-21:10 | 21.47 | 14.17 |
| May | 0.307365E+10 | 3881.86 | 13-MAY-07:52 | 24.60 | 19.68 | 0.128874E+09 | 83.64 | 13-MAY-05:00 | 24.60 | 19.68 |
| June | 0.304152E+10 | 3859.61 | 27-JUN-11:52 | 24.50 | 23.35 | 0.124709E+09 | 82.38 | 18-JUN-05:49 | 24.50 | 23.35 |
| July | 0.301125E+10 | 1720.60 | 02-JUL-17:35 | 39.83 | 26.58 | 0.128775E+09 | 70.27 | 13-JUL-23:30 | 31.45 | 27.03 |
| August | 0.277779E+10 | 1560.66 | 07-AUG-17:12 | 36.37 | 26.97 | 0.128775E+09 | 70.27 | 19-AUG-22:40 | 26.53 | 26.10 |
| September | 0.239339E+10 | 4082.09 | 29-SEP-06:22 | 24.65 | 21.40 | 0.124751E+09 | 82.33 | 29-SEP-05:00 | 24.65 | 21.40 |
| October | 0.188641E+10 | 5154.82 | 24-OCT-21:42 | 21.18 | 16.67 | 0.133482E+09 | 94.23 | 11-OCT-20:10 | 21.18 | 16.67 |
| November | 0.104024E+10 | 5347.01 | 23-NOV-21:12 | 14.50 | 11.83 | 0.132021E+09 | 89.71 | 02-NOV-20:40 | 14.50 | 11.83 |
| December | 0.480135E+09 | 5364.50 | 01-DEC-20:12 | 13.37 | 12.16 | 0.131611E+09 | 85.88 | 28-DEC-22:00 | 17.20 | 13.76 |
| Annual Sum or Average | 0.226842E+11 | 0.154276E+10 | ||||||||
| Minimum of Months | 0.361323E+09 | 1560.66 | 13.37 | 11.17 | 0.123023E+09 | 70.27 | 14.27 | 11.17 | ||
| Maximum of Months | 0.307365E+10 | 5364.50 | 39.83 | 26.97 | 0.135674E+09 | 94.23 | 31.45 | 27.03 |
Report: ZoneCoolingSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.110727E+10 | 5487.28 | 07-JAN-19:02 | 13.68 | 11.36 | 0.134245E+09 | 99.25 | 12-JAN-18:49 | 18.87 | 13.42 |
| February | 0.138709E+10 | 5468.86 | 27-FEB-21:02 | 17.52 | 13.45 | 0.124431E+09 | 102.44 | 04-FEB-18:30 | 17.52 | 13.45 |
| March | 0.223722E+10 | 5428.56 | 02-MAR-20:32 | 19.77 | 14.63 | 0.131300E+09 | 97.27 | 21-MAR-17:49 | 22.32 | 14.64 |
| April | 0.287664E+10 | 5397.60 | 09-APR-20:52 | 21.70 | 14.20 | 0.126008E+09 | 92.49 | 09-APR-20:40 | 21.70 | 14.20 |
| May | 0.316824E+10 | 3904.96 | 13-MAY-07:52 | 24.60 | 19.68 | 0.125882E+09 | 89.63 | 13-MAY-07:00 | 24.60 | 19.68 |
| June | 0.302783E+10 | 3940.51 | 27-JUN-11:52 | 24.50 | 23.35 | 0.120509E+09 | 89.32 | 18-JUN-06:00 | 24.50 | 23.35 |
| July | 0.301778E+10 | 1721.10 | 02-JUL-17:02 | 40.18 | 26.57 | 0.129276E+09 | 70.27 | 03-JUL-03:49 | 31.15 | 25.72 |
| August | 0.286789E+10 | 1643.15 | 06-AUG-16:20 | 36.20 | 26.31 | 0.123963E+09 | 70.27 | 19-AUG-09:00 | 30.10 | 27.00 |
| September | 0.278244E+10 | 4233.84 | 29-SEP-06:22 | 24.65 | 21.40 | 0.124111E+09 | 89.41 | 27-SEP-06:00 | 24.65 | 21.40 |
| October | 0.282925E+10 | 5417.41 | 24-OCT-20:52 | 21.60 | 16.34 | 0.132991E+09 | 95.62 | 11-OCT-20:10 | 21.60 | 16.34 |
| November | 0.215719E+10 | 5495.46 | 26-NOV-21:32 | 14.60 | 11.35 | 0.133837E+09 | 103.28 | 26-NOV-16:19 | 14.60 | 11.35 |
| December | 0.140371E+10 | 5507.26 | 08-DEC-17:01 | 18.15 | 13.70 | 0.136128E+09 | 100.73 | 02-DEC-17:40 | 18.15 | 13.70 |
| Annual Sum or Average | 0.288625E+11 | 0.154268E+10 | ||||||||
| Minimum of Months | 0.110727E+10 | 1643.15 | 13.68 | 11.35 | 0.120509E+09 | 70.27 | 14.60 | 11.35 | ||
| Maximum of Months | 0.316824E+10 | 5507.26 | 40.18 | 26.57 | 0.136128E+09 | 103.28 | 31.15 | 27.00 |
Report: ZoneCoolingSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.110858E+10 | 5484.70 | 07-JAN-19:02 | 13.68 | 11.36 | 0.134246E+09 | 99.23 | 12-JAN-18:49 | 18.87 | 13.42 |
| February | 0.139062E+10 | 5464.75 | 27-FEB-21:02 | 17.52 | 13.45 | 0.124444E+09 | 102.46 | 04-FEB-18:30 | 17.52 | 13.45 |
| March | 0.224130E+10 | 5425.14 | 02-MAR-20:32 | 19.77 | 14.63 | 0.131307E+09 | 97.37 | 21-MAR-17:49 | 22.32 | 14.64 |
| April | 0.287846E+10 | 5393.99 | 09-APR-20:52 | 21.70 | 14.20 | 0.126009E+09 | 92.47 | 09-APR-20:40 | 21.70 | 14.20 |
| May | 0.316941E+10 | 3902.12 | 13-MAY-07:52 | 24.60 | 19.68 | 0.125882E+09 | 89.63 | 13-MAY-07:00 | 24.60 | 19.68 |
| June | 0.302644E+10 | 3937.44 | 27-JUN-11:52 | 24.50 | 23.35 | 0.120508E+09 | 89.29 | 18-JUN-06:00 | 24.50 | 23.35 |
| July | 0.301804E+10 | 1716.89 | 02-JUL-16:40 | 40.33 | 26.50 | 0.129276E+09 | 70.27 | 30-JUL-23:10 | 30.75 | 26.80 |
| August | 0.286822E+10 | 1640.80 | 06-AUG-16:20 | 36.20 | 26.31 | 0.123963E+09 | 70.27 | 16-AUG-18:10 | 28.72 | 27.04 |
| September | 0.278217E+10 | 4230.35 | 29-SEP-06:22 | 24.65 | 21.40 | 0.124110E+09 | 89.39 | 27-SEP-06:00 | 24.65 | 21.40 |
| October | 0.283110E+10 | 5413.69 | 24-OCT-20:52 | 21.60 | 16.34 | 0.132991E+09 | 95.62 | 11-OCT-20:10 | 21.60 | 16.34 |
| November | 0.215955E+10 | 5492.03 | 26-NOV-21:32 | 14.60 | 11.35 | 0.133839E+09 | 103.30 | 26-NOV-16:19 | 14.60 | 11.35 |
| December | 0.140529E+10 | 5503.54 | 08-DEC-17:01 | 18.15 | 13.70 | 0.136135E+09 | 100.71 | 02-DEC-17:40 | 18.15 | 13.70 |
| Annual Sum or Average | 0.288792E+11 | 0.154271E+10 | ||||||||
| Minimum of Months | 0.110858E+10 | 1640.80 | 13.68 | 11.35 | 0.120508E+09 | 70.27 | 14.60 | 11.35 | ||
| Maximum of Months | 0.316941E+10 | 5503.54 | 40.33 | 26.50 | 0.136135E+09 | 103.30 | 30.75 | 27.04 |
Report: ZoneCoolingSummaryMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.375920E+09 | 6901.39 | 19-JAN-17:12 | 18.30 | 13.58 | 0.107859E+09 | 106.69 | 08-JAN-16:40 | 18.30 | 13.58 |
| February | 0.898575E+09 | 7094.24 | 15-FEB-14:22 | 22.90 | 16.64 | 0.112024E+09 | 114.60 | 20-FEB-18:19 | 22.20 | 14.17 |
| March | 0.239753E+10 | 6890.04 | 19-MAR-19:42 | 21.12 | 14.60 | 0.128651E+09 | 107.70 | 15-MAR-18:00 | 21.12 | 14.60 |
| April | 0.399353E+10 | 6839.00 | 09-APR-20:52 | 21.70 | 14.20 | 0.125370E+09 | 98.20 | 09-APR-20:40 | 21.70 | 14.20 |
| May | 0.482222E+10 | 4926.08 | 13-MAY-07:52 | 24.60 | 19.68 | 0.125885E+09 | 92.42 | 13-MAY-07:00 | 24.60 | 19.68 |
| June | 0.467908E+10 | 4967.92 | 27-JUN-11:52 | 24.50 | 23.35 | 0.120502E+09 | 89.45 | 18-JUN-06:00 | 24.50 | 23.35 |
| July | 0.438089E+10 | 3593.75 | 02-JUL-16:30 | 40.35 | 26.46 | 0.129276E+09 | 70.27 | 02-JUL-01:39 | 40.35 | 26.46 |
| August | 0.398020E+10 | 3201.32 | 06-AUG-16:20 | 36.20 | 26.31 | 0.123963E+09 | 70.27 | 28-AUG-01:19 | 29.90 | 27.43 |
| September | 0.360915E+10 | 5066.25 | 29-SEP-06:22 | 24.65 | 21.40 | 0.124077E+09 | 86.10 | 27-SEP-06:00 | 24.65 | 21.40 |
| October | 0.323398E+10 | 6870.17 | 24-OCT-20:52 | 21.60 | 16.34 | 0.130880E+09 | 101.42 | 11-OCT-18:19 | 21.60 | 16.34 |
| November | 0.184268E+10 | 6984.96 | 28-NOV-15:32 | 22.83 | 15.37 | 0.126573E+09 | 115.71 | 26-NOV-16:19 | 22.83 | 15.37 |
| December | 0.578781E+09 | 7010.98 | 08-DEC-17:01 | 18.15 | 13.70 | 0.113270E+09 | 109.67 | 02-DEC-16:40 | 18.15 | 13.70 |
| Annual Sum or Average | 0.347925E+11 | 0.146833E+10 | ||||||||
| Minimum of Months | 0.375920E+09 | 3201.32 | 18.15 | 13.58 | 0.107859E+09 | 70.27 | 18.15 | 13.58 | ||
| Maximum of Months | 0.482222E+10 | 7094.24 | 40.35 | 26.46 | 0.130880E+09 | 115.71 | 40.35 | 27.43 |
Report: ZoneCoolingSummaryMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 90435794.13 | 3135.99 | 14-JAN-22:52 | 17.30 | 13.73 | 94922191.61 | 80.09 | 14-JAN-18:10 | 17.30 | 13.73 |
| February | 0.357908E+09 | 6849.19 | 21-FEB-19:42 | 20.15 | 14.74 | 0.107164E+09 | 93.82 | 25-FEB-21:10 | 17.88 | 15.63 |
| March | 0.170378E+10 | 6866.38 | 22-MAR-20:12 | 22.20 | 15.42 | 0.132849E+09 | 98.06 | 13-MAR-21:40 | 22.20 | 15.42 |
| April | 0.350903E+10 | 6806.75 | 09-APR-21:12 | 21.47 | 14.17 | 0.125945E+09 | 96.92 | 09-APR-20:49 | 21.47 | 14.17 |
| May | 0.472140E+10 | 4966.02 | 13-MAY-07:52 | 24.60 | 19.68 | 0.128872E+09 | 82.35 | 13-MAY-05:00 | 24.60 | 19.68 |
| June | 0.469238E+10 | 4941.55 | 27-JUN-11:52 | 24.50 | 23.35 | 0.124704E+09 | 81.09 | 18-JUN-05:00 | 24.50 | 23.35 |
| July | 0.437416E+10 | 3535.68 | 02-JUL-16:50 | 40.32 | 26.53 | 0.128775E+09 | 70.27 | 02-JUL-00:49 | 40.32 | 26.53 |
| August | 0.388185E+10 | 3053.87 | 07-AUG-16:20 | 36.93 | 26.75 | 0.128775E+09 | 70.27 | 25-AUG-23:40 | 26.33 | 25.94 |
| September | 0.319948E+10 | 4999.88 | 29-SEP-06:22 | 24.65 | 21.40 | 0.124725E+09 | 79.93 | 29-SEP-05:00 | 24.65 | 21.40 |
| October | 0.225615E+10 | 6705.98 | 24-OCT-21:42 | 21.18 | 16.67 | 0.131890E+09 | 99.61 | 11-OCT-20:10 | 21.18 | 16.67 |
| November | 0.811173E+09 | 6858.39 | 01-NOV-20:22 | 20.00 | 15.16 | 0.123152E+09 | 93.68 | 05-NOV-20:10 | 20.17 | 16.56 |
| December | 0.122076E+09 | 6807.16 | 01-DEC-20:12 | 13.37 | 12.16 | 99641305.55 | 84.90 | 28-DEC-21:10 | 18.85 | 14.08 |
| Annual Sum or Average | 0.297198E+11 | 0.145142E+10 | ||||||||
| Minimum of Months | 90435794.13 | 3053.87 | 13.37 | 12.16 | 94922191.61 | 70.27 | 17.30 | 13.73 | ||
| Maximum of Months | 0.472140E+10 | 6866.38 | 40.32 | 26.75 | 0.132849E+09 | 99.61 | 40.32 | 26.53 |
Report: ZoneCoolingSummaryMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.358963E+09 | 6585.10 | 19-JAN-15:32 | 19.50 | 14.00 | 0.107304E+09 | 101.39 | 07-JAN-16:19 | 19.50 | 14.00 |
| February | 0.899100E+09 | 6844.79 | 15-FEB-14:22 | 22.90 | 16.64 | 0.112039E+09 | 110.07 | 18-FEB-17:30 | 22.90 | 13.43 |
| March | 0.239424E+10 | 6680.41 | 16-MAR-13:12 | 24.40 | 14.84 | 0.128755E+09 | 105.33 | 05-MAR-10:20 | 24.40 | 14.84 |
| April | 0.401144E+10 | 6537.41 | 09-APR-20:52 | 21.70 | 14.20 | 0.125450E+09 | 96.39 | 09-APR-20:40 | 21.70 | 14.20 |
| May | 0.485373E+10 | 4716.33 | 13-MAY-07:52 | 24.60 | 19.68 | 0.125884E+09 | 92.48 | 13-MAY-07:49 | 24.60 | 19.68 |
| June | 0.462444E+10 | 4756.99 | 27-JUN-11:52 | 24.50 | 23.35 | 0.120501E+09 | 89.24 | 18-JUN-06:00 | 24.50 | 23.35 |
| July | 0.438590E+10 | 3048.62 | 07-JUL-15:10 | 40.35 | 24.63 | 0.129276E+09 | 70.27 | 26-JUL-01:19 | 28.17 | 24.93 |
| August | 0.398661E+10 | 2866.67 | 07-AUG-15:10 | 37.27 | 26.59 | 0.123963E+09 | 70.27 | 20-AUG-09:00 | 29.20 | 27.36 |
| September | 0.359550E+10 | 4827.96 | 29-SEP-06:22 | 24.65 | 21.40 | 0.124076E+09 | 86.58 | 27-SEP-06:00 | 24.65 | 21.40 |
| October | 0.325276E+10 | 6567.87 | 24-OCT-20:52 | 21.60 | 16.34 | 0.130986E+09 | 101.14 | 11-OCT-18:19 | 21.60 | 16.34 |
| November | 0.182960E+10 | 6654.04 | 28-NOV-15:32 | 22.83 | 15.37 | 0.126427E+09 | 111.56 | 26-NOV-16:19 | 22.83 | 15.37 |
| December | 0.560053E+09 | 6684.92 | 08-DEC-17:01 | 18.15 | 13.70 | 0.113005E+09 | 104.10 | 03-DEC-16:30 | 18.15 | 13.70 |
| Annual Sum or Average | 0.347523E+11 | 0.146767E+10 | ||||||||
| Minimum of Months | 0.358963E+09 | 2866.67 | 18.15 | 13.70 | 0.107304E+09 | 70.27 | 18.15 | 13.43 | ||
| Maximum of Months | 0.485373E+10 | 6844.79 | 40.35 | 26.59 | 0.130986E+09 | 111.56 | 29.20 | 27.36 |
Report: ZoneCoolingSummaryMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 92244014.07 | 2202.25 | 26-JAN-20:42 | 14.92 | 11.74 | 93500373.90 | 73.84 | 14-JAN-22:49 | 14.92 | 11.74 |
| February | 0.349352E+09 | 6554.02 | 16-FEB-14:21 | 23.45 | 12.68 | 0.106690E+09 | 90.66 | 25-FEB-21:10 | 17.88 | 15.63 |
| March | 0.168603E+10 | 6567.33 | 21-MAR-19:42 | 21.22 | 14.35 | 0.133158E+09 | 97.26 | 13-MAR-21:40 | 21.22 | 14.35 |
| April | 0.352449E+10 | 6513.73 | 09-APR-21:12 | 21.47 | 14.17 | 0.126067E+09 | 95.08 | 09-APR-20:49 | 21.47 | 14.17 |
| May | 0.475317E+10 | 4756.21 | 13-MAY-07:52 | 24.60 | 19.68 | 0.128871E+09 | 82.17 | 13-MAY-05:00 | 24.60 | 19.68 |
| June | 0.463784E+10 | 4729.90 | 27-JUN-11:52 | 24.50 | 23.35 | 0.124703E+09 | 80.89 | 18-JUN-05:00 | 24.50 | 23.35 |
| July | 0.437922E+10 | 3034.16 | 07-JUL-16:01 | 39.98 | 24.76 | 0.128775E+09 | 70.27 | 18-JUL-02:39 | 30.10 | 26.36 |
| August | 0.388826E+10 | 2733.00 | 07-AUG-16:01 | 37.02 | 26.70 | 0.128775E+09 | 70.27 | 28-AUG-00:30 | 30.15 | 27.67 |
| September | 0.318568E+10 | 4760.84 | 29-SEP-06:22 | 24.65 | 21.40 | 0.124725E+09 | 79.72 | 29-SEP-05:00 | 24.65 | 21.40 |
| October | 0.226497E+10 | 6419.73 | 24-OCT-21:42 | 21.18 | 16.67 | 0.131954E+09 | 99.44 | 11-OCT-20:10 | 21.18 | 16.67 |
| November | 0.781166E+09 | 6555.91 | 29-NOV-18:02 | 20.87 | 15.76 | 0.121992E+09 | 91.31 | 05-NOV-20:10 | 20.87 | 15.76 |
| December | 0.120261E+09 | 6474.62 | 01-DEC-15:41 | 22.48 | 13.67 | 98266526.75 | 77.18 | 28-DEC-21:10 | 18.85 | 14.08 |
| Annual Sum or Average | 0.296627E+11 | 0.144748E+10 | ||||||||
| Minimum of Months | 92244014.07 | 2202.25 | 14.92 | 11.74 | 93500373.90 | 70.27 | 14.92 | 11.74 | ||
| Maximum of Months | 0.475317E+10 | 6567.33 | 39.98 | 26.70 | 0.133158E+09 | 99.44 | 30.15 | 27.67 |
Report: ZoneCoolingSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.117501E+09 | 4650.06 | 14-JAN-22:52 | 17.30 | 13.73 | 97464307.89 | 79.05 | 14-JAN-22:00 | 17.30 | 13.73 |
| February | 0.336552E+09 | 5937.06 | 21-FEB-19:42 | 20.15 | 14.74 | 0.110344E+09 | 95.33 | 25-FEB-21:10 | 17.88 | 15.63 |
| March | 0.139765E+10 | 5950.78 | 21-MAR-19:42 | 21.22 | 14.35 | 0.133972E+09 | 96.26 | 21-MAR-21:10 | 20.53 | 14.18 |
| April | 0.272782E+10 | 5910.35 | 09-APR-21:12 | 21.47 | 14.17 | 0.126133E+09 | 94.56 | 09-APR-20:00 | 21.47 | 14.17 |
| May | 0.368262E+10 | 4327.25 | 13-MAY-07:52 | 24.60 | 19.68 | 0.128875E+09 | 82.82 | 13-MAY-05:00 | 24.60 | 19.68 |
| June | 0.368394E+10 | 4248.96 | 27-JUN-11:52 | 24.50 | 23.35 | 0.124708E+09 | 81.61 | 18-JUN-05:00 | 24.50 | 23.35 |
| July | 0.355432E+10 | 2382.88 | 02-JUL-17:17 | 40.07 | 26.58 | 0.128775E+09 | 70.27 | 16-JUL-00:10 | 33.87 | 27.31 |
| August | 0.320118E+10 | 2149.88 | 07-AUG-16:20 | 36.93 | 26.75 | 0.128775E+09 | 70.27 | 27-AUG-00:30 | 29.05 | 26.85 |
| September | 0.263152E+10 | 4345.71 | 29-SEP-06:22 | 24.65 | 21.40 | 0.124731E+09 | 80.34 | 29-SEP-05:00 | 24.65 | 21.40 |
| October | 0.185955E+10 | 5800.06 | 24-OCT-21:42 | 21.18 | 16.67 | 0.132412E+09 | 100.15 | 11-OCT-20:10 | 21.18 | 16.67 |
| November | 0.679249E+09 | 5947.64 | 01-NOV-20:22 | 20.00 | 15.16 | 0.126149E+09 | 91.44 | 05-NOV-20:10 | 20.17 | 16.56 |
| December | 0.158223E+09 | 5834.79 | 01-DEC-15:41 | 22.48 | 13.67 | 0.104083E+09 | 80.21 | 28-DEC-21:10 | 18.85 | 14.08 |
| Annual Sum or Average | 0.240301E+11 | 0.146642E+10 | ||||||||
| Minimum of Months | 0.117501E+09 | 2149.88 | 17.30 | 13.67 | 97464307.89 | 70.27 | 17.30 | 13.73 | ||
| Maximum of Months | 0.368394E+10 | 5950.78 | 40.07 | 26.75 | 0.133972E+09 | 100.15 | 33.87 | 27.31 |
Report: ZoneCoolingSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.117305E+09 | 4519.33 | 14-JAN-22:52 | 17.30 | 13.73 | 97390762.58 | 78.77 | 14-JAN-22:00 | 17.30 | 13.73 |
| February | 0.339417E+09 | 5926.20 | 21-FEB-19:42 | 20.15 | 14.74 | 0.110391E+09 | 95.18 | 25-FEB-21:10 | 17.88 | 15.63 |
| March | 0.140341E+10 | 5941.67 | 21-MAR-19:42 | 21.22 | 14.35 | 0.133994E+09 | 96.40 | 21-MAR-21:10 | 20.53 | 14.18 |
| April | 0.273032E+10 | 5900.38 | 09-APR-21:12 | 21.47 | 14.17 | 0.126135E+09 | 94.45 | 09-APR-20:00 | 21.47 | 14.17 |
| May | 0.368423E+10 | 4319.18 | 13-MAY-07:52 | 24.60 | 19.68 | 0.128875E+09 | 82.80 | 13-MAY-05:00 | 24.60 | 19.68 |
| June | 0.368237E+10 | 4241.46 | 27-JUN-11:52 | 24.50 | 23.35 | 0.124708E+09 | 81.59 | 18-JUN-05:00 | 24.50 | 23.35 |
| July | 0.355465E+10 | 2369.92 | 02-JUL-17:17 | 40.07 | 26.58 | 0.128775E+09 | 70.27 | 15-JUL-00:40 | 31.50 | 27.22 |
| August | 0.320161E+10 | 2144.21 | 07-AUG-16:20 | 36.93 | 26.75 | 0.128775E+09 | 70.27 | 30-AUG-01:10 | 28.78 | 27.65 |
| September | 0.263133E+10 | 4336.61 | 29-SEP-06:22 | 24.65 | 21.40 | 0.124731E+09 | 80.33 | 29-SEP-05:00 | 24.65 | 21.40 |
| October | 0.186259E+10 | 5789.65 | 24-OCT-21:42 | 21.18 | 16.67 | 0.132408E+09 | 100.14 | 11-OCT-20:10 | 21.18 | 16.67 |
| November | 0.682152E+09 | 5937.13 | 01-NOV-20:22 | 20.00 | 15.16 | 0.126072E+09 | 91.33 | 05-NOV-20:10 | 20.17 | 16.56 |
| December | 0.158125E+09 | 5829.47 | 01-DEC-15:41 | 22.48 | 13.67 | 0.104010E+09 | 79.85 | 28-DEC-21:10 | 18.85 | 14.08 |
| Annual Sum or Average | 0.240475E+11 | 0.146626E+10 | ||||||||
| Minimum of Months | 0.117305E+09 | 2144.21 | 17.30 | 13.67 | 97390762.58 | 70.27 | 17.30 | 13.73 | ||
| Maximum of Months | 0.368423E+10 | 5941.67 | 40.07 | 26.75 | 0.133994E+09 | 100.14 | 31.50 | 27.65 |
Report: ZoneCoolingSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.459977E+09 | 6001.81 | 07-JAN-19:02 | 13.68 | 11.36 | 0.114851E+09 | 101.66 | 08-JAN-16:40 | 21.07 | 14.07 |
| February | 0.909750E+09 | 6141.34 | 15-FEB-14:22 | 22.90 | 16.64 | 0.116970E+09 | 109.00 | 18-FEB-17:30 | 22.90 | 13.43 |
| March | 0.211018E+10 | 6031.86 | 16-MAR-13:12 | 24.40 | 14.84 | 0.129767E+09 | 103.36 | 21-MAR-17:49 | 22.32 | 14.64 |
| April | 0.321598E+10 | 5941.90 | 09-APR-21:52 | 21.00 | 14.09 | 0.125560E+09 | 95.80 | 09-APR-20:40 | 21.00 | 14.09 |
| May | 0.378398E+10 | 4300.00 | 13-MAY-07:52 | 24.60 | 19.68 | 0.125890E+09 | 92.50 | 13-MAY-07:49 | 24.60 | 19.68 |
| June | 0.367036E+10 | 4279.25 | 27-JUN-11:52 | 24.50 | 23.35 | 0.120507E+09 | 90.60 | 18-JUN-06:00 | 24.50 | 23.35 |
| July | 0.356122E+10 | 2431.06 | 02-JUL-16:17 | 40.37 | 26.43 | 0.129276E+09 | 70.27 | 15-JUL-09:30 | 31.80 | 27.27 |
| August | 0.330026E+10 | 2274.57 | 06-AUG-16:02 | 36.25 | 26.27 | 0.123963E+09 | 70.27 | 05-AUG-01:30 | 36.25 | 26.27 |
| September | 0.304505E+10 | 4420.92 | 29-SEP-06:22 | 24.65 | 21.40 | 0.124084E+09 | 87.13 | 27-SEP-06:00 | 24.65 | 21.40 |
| October | 0.285203E+10 | 5959.52 | 24-OCT-20:52 | 21.60 | 16.34 | 0.131495E+09 | 101.00 | 11-OCT-20:10 | 21.60 | 16.34 |
| November | 0.176163E+10 | 6039.47 | 28-NOV-15:32 | 22.83 | 15.37 | 0.130438E+09 | 110.80 | 26-NOV-16:19 | 22.83 | 15.37 |
| December | 0.658771E+09 | 6069.52 | 08-DEC-17:01 | 18.15 | 13.70 | 0.121473E+09 | 104.70 | 02-DEC-16:40 | 18.15 | 13.70 |
| Annual Sum or Average | 0.293292E+11 | 0.149427E+10 | ||||||||
| Minimum of Months | 0.459977E+09 | 2274.57 | 13.68 | 11.36 | 0.114851E+09 | 70.27 | 18.15 | 13.43 | ||
| Maximum of Months | 0.378398E+10 | 6141.34 | 40.37 | 26.43 | 0.131495E+09 | 110.80 | 36.25 | 27.27 |
Report: ZoneCoolingSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.461715E+09 | 5991.61 | 07-JAN-19:02 | 13.68 | 11.36 | 0.114843E+09 | 101.74 | 07-JAN-16:19 | 13.68 | 11.36 |
| February | 0.914468E+09 | 6138.97 | 15-FEB-14:22 | 22.90 | 16.64 | 0.116968E+09 | 109.00 | 18-FEB-17:30 | 22.90 | 13.43 |
| March | 0.211548E+10 | 6023.18 | 16-MAR-13:12 | 24.40 | 14.84 | 0.129768E+09 | 103.46 | 21-MAR-17:49 | 22.32 | 14.64 |
| April | 0.321839E+10 | 5931.47 | 09-APR-21:52 | 21.00 | 14.09 | 0.125561E+09 | 95.72 | 09-APR-20:40 | 21.00 | 14.09 |
| May | 0.378562E+10 | 4292.04 | 13-MAY-07:52 | 24.60 | 19.68 | 0.125890E+09 | 92.48 | 13-MAY-07:49 | 24.60 | 19.68 |
| June | 0.366881E+10 | 4271.78 | 27-JUN-11:52 | 24.50 | 23.35 | 0.120507E+09 | 90.58 | 18-JUN-06:00 | 24.50 | 23.35 |
| July | 0.356156E+10 | 2421.52 | 02-JUL-16:20 | 40.37 | 26.43 | 0.129276E+09 | 70.27 | 08-JUL-08:50 | 34.30 | 28.36 |
| August | 0.330070E+10 | 2268.19 | 06-AUG-16:02 | 36.25 | 26.27 | 0.123963E+09 | 70.27 | 13-AUG-01:10 | 29.05 | 26.92 |
| September | 0.304487E+10 | 4411.90 | 29-SEP-06:22 | 24.65 | 21.40 | 0.124083E+09 | 87.11 | 27-SEP-06:00 | 24.65 | 21.40 |
| October | 0.285474E+10 | 5948.54 | 24-OCT-20:52 | 21.60 | 16.34 | 0.131492E+09 | 100.99 | 11-OCT-20:10 | 21.60 | 16.34 |
| November | 0.176492E+10 | 6028.49 | 28-NOV-15:32 | 22.83 | 15.37 | 0.130412E+09 | 110.79 | 26-NOV-16:19 | 22.83 | 15.37 |
| December | 0.660828E+09 | 6058.87 | 08-DEC-17:01 | 18.15 | 13.70 | 0.121459E+09 | 104.62 | 02-DEC-16:40 | 18.15 | 13.70 |
| Annual Sum or Average | 0.293521E+11 | 0.149422E+10 | ||||||||
| Minimum of Months | 0.461715E+09 | 2268.19 | 13.68 | 11.36 | 0.114843E+09 | 70.27 | 13.68 | 11.36 | ||
| Maximum of Months | 0.378562E+10 | 6138.97 | 40.37 | 26.43 | 0.131492E+09 | 110.79 | 34.30 | 28.36 |
Report: ZoneCoolingSummaryMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 7.83 | 7.49 | 0.185187E+09 | 146.22 | 14-JAN-21:10 | 17.67 | 13.83 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 9.73 | 7.85 | 0.209290E+09 | 161.46 | 15-FEB-21:10 | 17.13 | 15.45 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 15.55 | 12.96 | 0.269993E+09 | 172.90 | 28-MAR-20:10 | 28.48 | 18.89 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 23.70 | 16.77 | 0.285117E+09 | 184.84 | 28-APR-20:10 | 34.95 | 19.09 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 30.53 | 18.24 | 0.310201E+09 | 191.12 | 04-MAY-20:10 | 34.88 | 23.02 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 | 22.58 | 0.303060E+09 | 193.89 | 12-JUN-20:10 | 38.43 | 22.54 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 | 24.65 | 0.308248E+09 | 191.41 | 04-JUL-20:10 | 39.85 | 24.37 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 | 26.26 | 0.301202E+09 | 183.45 | 07-AUG-20:10 | 34.07 | 27.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 | 25.91 | 0.282907E+09 | 178.15 | 17-SEP-20:10 | 37.37 | 27.68 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 | 21.85 | 0.277726E+09 | 170.76 | 01-OCT-20:10 | 27.03 | 21.10 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 17.72 | 15.09 | 0.241157E+09 | 157.83 | 08-NOV-21:10 | 20.15 | 17.59 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 12.50 | 9.11 | 0.199650E+09 | 147.74 | 28-DEC-21:10 | 18.85 | 14.08 |
| Annual Sum or Average | 0.00 | 0.317374E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 7.83 | 7.49 | 0.185187E+09 | 146.22 | 17.13 | 13.83 | ||
| Maximum of Months | 0.00 | 0.00 | 32.95 | 26.26 | 0.310201E+09 | 193.89 | 39.85 | 27.68 |
Report: ZoneCoolingSummaryMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 7.83 | 7.49 | 0.218877E+09 | 161.49 | 14-JAN-22:40 | 17.37 | 13.75 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 9.73 | 7.85 | 0.232782E+09 | 174.08 | 22-FEB-22:40 | 19.03 | 14.13 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 15.55 | 12.96 | 0.303627E+09 | 226.84 | 28-MAR-17:10 | 34.60 | 18.91 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 23.70 | 16.77 | 0.344849E+09 | 272.03 | 28-APR-17:10 | 39.07 | 19.90 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 30.53 | 18.24 | 0.389047E+09 | 312.00 | 03-MAY-17:10 | 42.68 | 21.29 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 | 22.58 | 0.382567E+09 | 324.19 | 07-JUN-17:10 | 43.85 | 21.80 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 | 24.65 | 0.384150E+09 | 290.10 | 02-JUL-17:10 | 40.18 | 26.57 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 | 26.26 | 0.372769E+09 | 255.30 | 07-AUG-17:10 | 36.48 | 26.95 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 | 25.91 | 0.352299E+09 | 237.53 | 26-SEP-17:10 | 34.60 | 22.33 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 | 21.85 | 0.343660E+09 | 237.46 | 02-OCT-17:10 | 34.42 | 21.24 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 17.72 | 15.09 | 0.289284E+09 | 187.69 | 04-NOV-21:40 | 18.60 | 15.59 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 12.50 | 9.11 | 0.248503E+09 | 169.65 | 01-DEC-00:10 | 12.50 | 9.11 |
| Annual Sum or Average | 0.00 | 0.386241E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 7.83 | 7.49 | 0.218877E+09 | 161.49 | 12.50 | 9.11 | ||
| Maximum of Months | 0.00 | 0.00 | 32.95 | 26.26 | 0.389047E+09 | 324.19 | 43.85 | 26.95 |
Report: ZoneCoolingSummaryMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 7.83 | 7.49 | 0.247757E+09 | 156.52 | 14-JAN-21:10 | 17.67 | 13.83 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 9.73 | 7.85 | 0.247692E+09 | 164.00 | 16-FEB-21:10 | 17.27 | 12.14 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 15.55 | 12.96 | 0.285449E+09 | 164.72 | 21-MAR-20:10 | 21.02 | 14.31 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 23.70 | 16.77 | 0.282143E+09 | 167.95 | 28-APR-20:10 | 34.95 | 19.09 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 30.53 | 18.24 | 0.296603E+09 | 170.73 | 04-MAY-20:10 | 34.88 | 23.02 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 | 22.58 | 0.286976E+09 | 172.07 | 12-JUN-20:10 | 38.43 | 22.54 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 | 24.65 | 0.293004E+09 | 169.94 | 04-JUL-20:10 | 39.85 | 24.37 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 | 26.26 | 0.289164E+09 | 166.14 | 07-AUG-20:10 | 34.07 | 27.23 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 | 25.91 | 0.276945E+09 | 163.70 | 17-SEP-20:10 | 37.37 | 27.68 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 | 21.85 | 0.286349E+09 | 162.85 | 01-OCT-20:10 | 27.03 | 21.10 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 17.72 | 15.09 | 0.271360E+09 | 160.94 | 28-NOV-21:10 | 17.73 | 13.57 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 12.50 | 9.11 | 0.263191E+09 | 159.86 | 01-DEC-21:10 | 12.15 | 11.68 |
| Annual Sum or Average | 0.00 | 0.332663E+10 | ||||||||
| Minimum of Months | 0.00 | 0.00 | 7.83 | 7.49 | 0.247692E+09 | 156.52 | 12.15 | 11.68 | ||
| Maximum of Months | 0.00 | 0.00 | 32.95 | 26.26 | 0.296603E+09 | 172.07 | 39.85 | 27.68 |
Report: ZoneHeatingSummaryMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 31304.54 | 26.07 | 12-JAN-14:25 | 23.45 |
| February | 315393.11 | 48.93 | 22-FEB-12:05 | 25.60 |
| March | 840330.34 | 57.14 | 28-MAR-09:15 | 26.40 |
| April | 977605.23 | 52.51 | 05-APR-09:15 | 25.87 |
| May | 20256.63 | 39.34 | 13-MAY-07:55 | 24.60 |
| June | 55110.33 | 40.65 | 18-JUN-06:55 | 24.80 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 37336.35 | 49.25 | 27-SEP-07:15 | 25.27 |
| October | 506396.79 | 58.49 | 02-OCT-07:35 | 26.17 |
| November | 412547.25 | 55.13 | 09-NOV-10:35 | 26.17 |
| December | 116902.68 | 37.28 | 25-DEC-13:55 | 24.50 |
| Annual Sum or Average | 3313183.25 | |||
| Minimum of Months | 0.00 | 0.00 | 23.45 | |
| Maximum of Months | 977605.23 | 58.49 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 385124.43 | 15.44 | 08-JAN-14:52 | 22.90 |
| February | 1819511.15 | 48.97 | 20-FEB-12:33 | 25.43 |
| March | 2551536.37 | 57.49 | 10-MAR-10:30 | 27.10 |
| April | 1397914.86 | 56.97 | 07-APR-09:15 | 26.50 |
| May | 21693.00 | 39.49 | 13-MAY-07:55 | 24.60 |
| June | 54362.51 | 40.47 | 18-JUN-06:55 | 24.80 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 47666.00 | 49.10 | 27-SEP-07:15 | 25.27 |
| October | 786656.87 | 61.93 | 28-OCT-10:35 | 26.53 |
| November | 1768776.17 | 64.23 | 04-NOV-10:55 | 27.00 |
| December | 435879.14 | 40.28 | 28-DEC-13:44 | 24.50 |
| Annual Sum or Average | 9269120.47 | |||
| Minimum of Months | 0.00 | 0.00 | 22.90 | |
| Maximum of Months | 2551536.37 | 64.23 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 63311091.95 | 967.73 | 03-JAN-07:01 | 5.50 |
| February | 0.144987E+09 | 421.06 | 24-FEB-17:25 | 24.80 |
| March | 0.381674E+09 | 810.01 | 28-MAR-16:13 | 35.30 |
| April | 0.606634E+09 | 982.58 | 27-APR-16:01 | 39.70 |
| May | 0.533972E+09 | 1178.61 | 03-MAY-16:01 | 44.12 |
| June | 0.484700E+09 | 1190.77 | 08-JUN-16:01 | 44.47 |
| July | 0.382685E+09 | 949.63 | 07-JUL-16:01 | 39.98 |
| August | 0.444342E+09 | 794.72 | 08-AUG-16:13 | 36.63 |
| September | 0.433969E+09 | 724.66 | 26-SEP-16:01 | 35.65 |
| October | 0.284146E+09 | 710.00 | 02-OCT-16:01 | 35.72 |
| November | 0.132940E+09 | 525.86 | 03-NOV-16:12 | 27.90 |
| December | 66614005.58 | 344.59 | 24-DEC-13:52 | 24.30 |
| Annual Sum or Average | 0.395997E+10 | |||
| Minimum of Months | 63311091.95 | 344.59 | 5.50 | |
| Maximum of Months | 0.606634E+09 | 1190.77 | 44.47 |
Report: ZoneHeatingSummaryMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 366706.32 | 15.09 | 08-JAN-14:52 | 22.90 |
| February | 1502262.32 | 48.87 | 22-FEB-12:05 | 25.60 |
| March | 1613875.42 | 60.88 | 10-MAR-10:15 | 26.63 |
| April | 837883.06 | 59.92 | 07-APR-09:15 | 26.50 |
| May | 16144.00 | 37.90 | 13-MAY-07:55 | 24.60 |
| June | 52965.75 | 39.39 | 18-JUN-06:55 | 24.80 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 43285.41 | 46.90 | 27-SEP-07:15 | 25.27 |
| October | 760550.90 | 61.04 | 15-OCT-09:05 | 26.53 |
| November | 842138.58 | 65.84 | 04-NOV-10:55 | 27.00 |
| December | 407154.96 | 40.83 | 25-DEC-14:25 | 24.30 |
| Annual Sum or Average | 6442966.71 | |||
| Minimum of Months | 0.00 | 0.00 | 22.90 | |
| Maximum of Months | 1613875.42 | 65.84 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 269132.90 | 13.27 | 08-JAN-14:52 | 22.90 |
| February | 1608119.71 | 45.56 | 22-FEB-12:05 | 25.60 |
| March | 2531274.86 | 59.93 | 10-MAR-10:15 | 26.63 |
| April | 1357973.56 | 59.38 | 07-APR-09:15 | 26.50 |
| May | 23840.36 | 33.49 | 13-MAY-08:10 | 24.87 |
| June | 59588.60 | 37.17 | 27-JUN-11:56 | 24.50 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 41548.98 | 38.05 | 29-SEP-06:25 | 24.65 |
| October | 714720.54 | 61.81 | 15-OCT-09:05 | 26.53 |
| November | 1909671.99 | 66.73 | 04-NOV-10:55 | 27.00 |
| December | 436709.77 | 40.95 | 25-DEC-14:25 | 24.30 |
| Annual Sum or Average | 8952581.28 | |||
| Minimum of Months | 0.00 | 0.00 | 22.90 | |
| Maximum of Months | 2531274.86 | 66.73 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 263655.29 | 13.07 | 08-JAN-14:52 | 22.90 |
| February | 1579221.60 | 45.84 | 22-FEB-12:05 | 25.60 |
| March | 2512539.59 | 60.09 | 10-MAR-10:15 | 26.63 |
| April | 1351256.19 | 59.48 | 07-APR-09:15 | 26.50 |
| May | 23842.09 | 33.48 | 13-MAY-08:10 | 24.87 |
| June | 59690.92 | 37.16 | 27-JUN-11:56 | 24.50 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 41620.59 | 38.05 | 29-SEP-06:25 | 24.65 |
| October | 699840.04 | 61.86 | 15-OCT-09:05 | 26.53 |
| November | 1835609.86 | 66.92 | 04-NOV-10:55 | 27.00 |
| December | 430826.22 | 41.16 | 25-DEC-14:25 | 24.30 |
| Annual Sum or Average | 8798102.39 | |||
| Minimum of Months | 0.00 | 0.00 | 22.90 | |
| Maximum of Months | 2512539.59 | 66.92 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 40928.49 | 27.06 | 12-JAN-14:25 | 23.45 |
| February | 366667.54 | 50.39 | 22-FEB-12:05 | 25.60 |
| March | 737674.99 | 59.32 | 28-MAR-09:15 | 26.40 |
| April | 824765.64 | 54.94 | 11-APR-09:25 | 26.10 |
| May | 23259.88 | 33.38 | 13-MAY-08:10 | 24.87 |
| June | 59658.33 | 36.68 | 27-JUN-11:56 | 24.50 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 32929.82 | 44.49 | 27-SEP-07:15 | 25.27 |
| October | 446456.38 | 56.63 | 15-OCT-08:55 | 26.10 |
| November | 413699.44 | 50.11 | 01-NOV-11:05 | 25.85 |
| December | 110521.51 | 37.32 | 25-DEC-13:55 | 24.50 |
| Annual Sum or Average | 3056562.01 | |||
| Minimum of Months | 0.00 | 0.00 | 23.45 | |
| Maximum of Months | 824765.64 | 59.32 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 41302.96 | 27.41 | 12-JAN-14:25 | 23.45 |
| February | 373810.10 | 50.19 | 22-FEB-12:05 | 25.60 |
| March | 606296.40 | 58.79 | 28-MAR-09:15 | 26.40 |
| April | 650146.84 | 56.70 | 11-APR-09:25 | 26.10 |
| May | 11690.36 | 20.84 | 13-MAY-08:10 | 24.87 |
| June | 37953.80 | 37.64 | 27-JUN-11:56 | 24.50 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 29533.99 | 45.72 | 27-SEP-07:15 | 25.27 |
| October | 414406.03 | 57.32 | 02-OCT-07:35 | 26.17 |
| November | 391740.91 | 50.44 | 01-NOV-11:05 | 25.85 |
| December | 119200.70 | 37.37 | 25-DEC-13:55 | 24.50 |
| Annual Sum or Average | 2676082.09 | |||
| Minimum of Months | 0.00 | 0.00 | 23.45 | |
| Maximum of Months | 650146.84 | 58.79 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 21688.60 | 22.15 | 12-JAN-14:25 | 23.45 |
| February | 200335.20 | 46.11 | 22-FEB-12:05 | 25.60 |
| March | 491065.24 | 56.51 | 28-MAR-09:15 | 26.40 |
| April | 577546.78 | 51.01 | 05-APR-09:15 | 25.87 |
| May | 21802.25 | 39.41 | 13-MAY-07:55 | 24.60 |
| June | 72516.86 | 41.51 | 18-JUN-06:55 | 24.80 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 91137.87 | 45.75 | 27-SEP-07:15 | 25.27 |
| October | 705926.91 | 53.85 | 02-OCT-07:35 | 26.17 |
| November | 357650.90 | 55.31 | 09-NOV-10:35 | 26.17 |
| December | 83513.59 | 34.40 | 25-DEC-13:55 | 24.50 |
| Annual Sum or Average | 2623184.21 | |||
| Minimum of Months | 0.00 | 0.00 | 23.45 | |
| Maximum of Months | 705926.91 | 56.51 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 240753.07 | 11.99 | 08-JAN-14:52 | 22.90 |
| February | 894703.63 | 47.63 | 07-FEB-13:24 | 24.80 |
| March | 1331878.03 | 57.93 | 10-MAR-10:15 | 26.63 |
| April | 800513.88 | 56.82 | 07-APR-09:15 | 26.50 |
| May | 22260.97 | 39.17 | 13-MAY-07:55 | 24.60 |
| June | 72242.73 | 41.42 | 18-JUN-06:55 | 24.80 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 101539.95 | 44.42 | 27-SEP-07:15 | 25.27 |
| October | 1701153.69 | 56.36 | 09-OCT-09:25 | 26.35 |
| November | 1987172.55 | 56.41 | 04-NOV-10:55 | 27.00 |
| December | 556378.95 | 43.79 | 28-DEC-13:44 | 24.50 |
| Annual Sum or Average | 7708597.45 | |||
| Minimum of Months | 0.00 | 0.00 | 22.90 | |
| Maximum of Months | 1987172.55 | 57.93 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 22620.24 | 22.57 | 12-JAN-14:25 | 23.45 |
| February | 199146.85 | 44.80 | 22-FEB-12:05 | 25.60 |
| March | 379546.53 | 57.79 | 28-MAR-09:15 | 26.40 |
| April | 393845.65 | 53.03 | 11-APR-09:25 | 26.10 |
| May | 20831.09 | 39.02 | 13-MAY-07:55 | 24.60 |
| June | 74438.75 | 41.69 | 18-JUN-06:55 | 24.80 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 91671.94 | 46.67 | 27-SEP-07:15 | 25.27 |
| October | 557124.86 | 55.51 | 02-OCT-07:35 | 26.17 |
| November | 295647.98 | 51.32 | 09-NOV-10:35 | 26.17 |
| December | 89251.81 | 34.39 | 25-DEC-13:55 | 24.50 |
| Annual Sum or Average | 2124125.69 | |||
| Minimum of Months | 0.00 | 0.00 | 23.45 | |
| Maximum of Months | 557124.86 | 57.79 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 219360.95 | 11.36 | 08-JAN-14:52 | 22.90 |
| February | 591182.46 | 47.65 | 22-FEB-12:05 | 25.60 |
| March | 707727.69 | 61.43 | 10-MAR-10:15 | 26.63 |
| April | 531484.20 | 58.03 | 07-APR-09:15 | 26.50 |
| May | 21950.19 | 39.21 | 13-MAY-07:55 | 24.60 |
| June | 74183.26 | 41.60 | 18-JUN-06:55 | 24.80 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 104737.93 | 45.37 | 27-SEP-07:15 | 25.27 |
| October | 1150913.08 | 59.79 | 28-OCT-10:35 | 26.53 |
| November | 1275299.10 | 63.42 | 04-NOV-10:55 | 27.00 |
| December | 495351.26 | 41.37 | 28-DEC-13:44 | 24.50 |
| Annual Sum or Average | 5172190.13 | |||
| Minimum of Months | 0.00 | 0.00 | 22.90 | |
| Maximum of Months | 1275299.10 | 63.42 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 117897.31 | 8.39 | 08-JAN-14:52 | 22.90 |
| February | 886647.91 | 45.42 | 22-FEB-12:05 | 25.60 |
| March | 1491018.36 | 60.24 | 10-MAR-10:15 | 26.63 |
| April | 878094.35 | 58.40 | 07-APR-09:15 | 26.50 |
| May | 26295.61 | 37.40 | 13-MAY-07:55 | 24.60 |
| June | 76774.35 | 39.22 | 18-JUN-06:55 | 24.80 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 109401.36 | 46.04 | 27-SEP-07:15 | 25.27 |
| October | 1753370.16 | 58.53 | 25-OCT-09:55 | 26.50 |
| November | 1832186.18 | 60.36 | 04-NOV-10:55 | 27.00 |
| December | 466915.12 | 38.65 | 25-DEC-14:25 | 24.30 |
| Annual Sum or Average | 7638600.70 | |||
| Minimum of Months | 0.00 | 0.00 | 22.90 | |
| Maximum of Months | 1832186.18 | 60.36 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 113081.14 | 8.26 | 12-JAN-14:53 | 23.60 |
| February | 862927.31 | 45.76 | 22-FEB-12:05 | 25.60 |
| March | 1470846.14 | 60.43 | 10-MAR-10:15 | 26.63 |
| April | 874981.19 | 58.54 | 07-APR-09:15 | 26.50 |
| May | 26313.49 | 37.38 | 13-MAY-07:55 | 24.60 |
| June | 76959.04 | 39.21 | 18-JUN-06:55 | 24.80 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 109527.99 | 46.04 | 27-SEP-07:15 | 25.27 |
| October | 1746111.88 | 58.66 | 25-OCT-09:55 | 26.50 |
| November | 1819362.39 | 60.61 | 04-NOV-10:55 | 27.00 |
| December | 456791.18 | 38.85 | 25-DEC-14:25 | 24.30 |
| Annual Sum or Average | 7556901.75 | |||
| Minimum of Months | 0.00 | 0.00 | 23.60 | |
| Maximum of Months | 1819362.39 | 60.61 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 29215.74 | 23.29 | 12-JAN-14:25 | 23.45 |
| February | 232806.69 | 48.77 | 22-FEB-12:05 | 25.60 |
| March | 540970.86 | 59.02 | 28-MAR-09:15 | 26.40 |
| April | 638876.67 | 53.25 | 05-APR-09:15 | 25.87 |
| May | 25477.27 | 37.38 | 13-MAY-07:55 | 24.60 |
| June | 79593.09 | 39.38 | 18-JUN-06:55 | 24.80 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 94678.46 | 45.81 | 27-SEP-07:15 | 25.27 |
| October | 616493.67 | 56.21 | 02-OCT-07:35 | 26.17 |
| November | 352105.26 | 53.64 | 09-NOV-10:35 | 26.17 |
| December | 90085.81 | 36.00 | 25-DEC-13:55 | 24.50 |
| Annual Sum or Average | 2700303.50 | |||
| Minimum of Months | 0.00 | 0.00 | 23.45 | |
| Maximum of Months | 638876.67 | 59.02 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 29059.07 | 23.18 | 12-JAN-14:25 | 23.45 |
| February | 229988.12 | 48.65 | 22-FEB-12:05 | 25.60 |
| March | 531709.15 | 59.20 | 28-MAR-09:15 | 26.40 |
| April | 627169.27 | 53.35 | 11-APR-09:25 | 26.10 |
| May | 25494.30 | 37.37 | 13-MAY-07:55 | 24.60 |
| June | 79706.07 | 39.37 | 18-JUN-06:55 | 24.80 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 94794.13 | 45.79 | 27-SEP-07:15 | 25.27 |
| October | 616674.31 | 56.23 | 02-OCT-07:35 | 26.17 |
| November | 354381.53 | 53.18 | 09-NOV-10:35 | 26.17 |
| December | 86916.06 | 35.83 | 25-DEC-13:55 | 24.50 |
| Annual Sum or Average | 2675892.01 | |||
| Minimum of Months | 0.00 | 0.00 | 23.45 | |
| Maximum of Months | 627169.27 | 59.20 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.105002E+09 | 625.21 | 02-JAN-07:00 | 6.70 |
| February | 13745646.08 | 456.25 | 11-FEB-06:00 | 9.20 |
| March | 483858.13 | 53.19 | 28-MAR-09:15 | 26.40 |
| April | 1031065.91 | 57.01 | 11-APR-09:23 | 26.10 |
| May | 14606.78 | 41.12 | 13-MAY-07:55 | 24.60 |
| June | 87651.72 | 40.84 | 18-JUN-06:55 | 24.80 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 145784.28 | 42.12 | 27-SEP-07:15 | 25.27 |
| October | 1097693.33 | 55.92 | 02-OCT-07:33 | 26.17 |
| November | 342264.86 | 53.70 | 09-NOV-10:35 | 26.17 |
| December | 37094474.82 | 549.80 | 23-DEC-07:00 | 6.10 |
| Annual Sum or Average | 0.159045E+09 | |||
| Minimum of Months | 0.00 | 0.00 | 6.10 | |
| Maximum of Months | 0.105002E+09 | 625.21 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.319218E+09 | 815.64 | 02-JAN-06:00 | 6.40 |
| February | 40841351.73 | 454.76 | 11-FEB-06:00 | 9.20 |
| March | 1546220.98 | 61.20 | 26-MAR-10:13 | 26.23 |
| April | 1312952.46 | 58.09 | 11-APR-09:23 | 26.10 |
| May | 15726.73 | 40.78 | 13-MAY-07:55 | 24.60 |
| June | 86890.91 | 40.63 | 18-JUN-06:55 | 24.80 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 154825.76 | 41.14 | 27-SEP-07:15 | 25.27 |
| October | 2803631.17 | 62.76 | 15-OCT-09:03 | 26.53 |
| November | 3755989.25 | 69.53 | 04-NOV-10:53 | 27.00 |
| December | 0.139553E+09 | 790.96 | 23-DEC-06:00 | 5.30 |
| Annual Sum or Average | 0.509289E+09 | |||
| Minimum of Months | 0.00 | 0.00 | 5.30 | |
| Maximum of Months | 0.319218E+09 | 815.64 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 97947090.84 | 637.01 | 02-JAN-07:00 | 6.70 |
| February | 12564989.81 | 461.25 | 11-FEB-06:00 | 9.20 |
| March | 346785.39 | 57.13 | 28-MAR-09:15 | 26.40 |
| April | 559497.33 | 52.71 | 23-APR-08:45 | 25.78 |
| May | 14187.26 | 41.43 | 13-MAY-07:55 | 24.60 |
| June | 89066.39 | 41.26 | 18-JUN-06:55 | 24.80 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 145237.63 | 43.88 | 27-SEP-07:15 | 25.27 |
| October | 796937.63 | 53.27 | 15-OCT-08:55 | 26.10 |
| November | 264115.06 | 46.13 | 14-NOV-11:25 | 25.80 |
| December | 34620494.20 | 538.25 | 23-DEC-07:00 | 6.10 |
| Annual Sum or Average | 0.147348E+09 | |||
| Minimum of Months | 0.00 | 0.00 | 6.10 | |
| Maximum of Months | 97947090.84 | 637.01 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.294373E+09 | 833.90 | 02-JAN-06:00 | 6.40 |
| February | 35363332.90 | 459.80 | 11-FEB-06:00 | 9.20 |
| March | 656435.00 | 61.27 | 10-MAR-10:15 | 26.63 |
| April | 664187.94 | 55.99 | 07-APR-09:15 | 26.50 |
| May | 15228.41 | 41.33 | 13-MAY-07:55 | 24.60 |
| June | 88304.70 | 41.06 | 18-JUN-06:55 | 24.80 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 153496.07 | 42.95 | 27-SEP-07:15 | 25.27 |
| October | 1425391.63 | 59.52 | 28-OCT-10:35 | 26.53 |
| November | 1643380.95 | 63.23 | 04-NOV-10:55 | 27.00 |
| December | 0.132199E+09 | 779.37 | 23-DEC-06:00 | 5.30 |
| Annual Sum or Average | 0.466582E+09 | |||
| Minimum of Months | 0.00 | 0.00 | 5.30 | |
| Maximum of Months | 0.294373E+09 | 833.90 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.108797E+09 | 462.60 | 02-JAN-06:00 | 6.40 |
| February | 4759295.40 | 105.01 | 11-FEB-06:00 | 9.20 |
| March | 1584386.73 | 60.20 | 10-MAR-10:15 | 26.63 |
| April | 1310955.86 | 59.79 | 07-APR-09:15 | 26.50 |
| May | 14016.07 | 38.70 | 13-MAY-07:55 | 24.60 |
| June | 84396.49 | 41.26 | 18-JUN-06:55 | 24.80 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 150890.61 | 44.29 | 27-SEP-07:15 | 25.27 |
| October | 2498437.22 | 59.17 | 25-OCT-09:55 | 26.50 |
| November | 3278971.50 | 59.66 | 04-NOV-11:10 | 27.33 |
| December | 37989621.92 | 408.77 | 23-DEC-06:00 | 5.30 |
| Annual Sum or Average | 0.160468E+09 | |||
| Minimum of Months | 0.00 | 0.00 | 5.30 | |
| Maximum of Months | 0.108797E+09 | 462.60 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.109396E+09 | 464.72 | 02-JAN-06:00 | 6.40 |
| February | 4648591.06 | 106.18 | 11-FEB-06:00 | 9.20 |
| March | 1475081.41 | 60.74 | 10-MAR-10:15 | 26.63 |
| April | 1279759.79 | 59.88 | 07-APR-09:15 | 26.50 |
| May | 14041.69 | 38.64 | 13-MAY-07:55 | 24.60 |
| June | 84520.80 | 41.22 | 18-JUN-06:55 | 24.80 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 150455.58 | 44.30 | 27-SEP-07:15 | 25.27 |
| October | 2405825.36 | 59.62 | 25-OCT-09:55 | 26.50 |
| November | 3173171.13 | 59.50 | 04-NOV-11:10 | 27.33 |
| December | 37947524.67 | 405.94 | 23-DEC-06:00 | 5.30 |
| Annual Sum or Average | 0.160575E+09 | |||
| Minimum of Months | 0.00 | 0.00 | 5.30 | |
| Maximum of Months | 0.109396E+09 | 464.72 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 9389346.61 | 245.32 | 02-JAN-06:00 | 6.40 |
| February | 1097784.39 | 106.74 | 11-FEB-06:00 | 9.20 |
| March | 525272.89 | 57.65 | 28-MAR-09:15 | 26.40 |
| April | 985319.29 | 53.95 | 23-APR-08:45 | 25.78 |
| May | 13110.26 | 38.65 | 13-MAY-07:55 | 24.60 |
| June | 85224.15 | 41.09 | 18-JUN-06:55 | 24.80 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 141368.82 | 45.31 | 27-SEP-07:15 | 25.27 |
| October | 965274.26 | 54.91 | 15-OCT-08:55 | 26.10 |
| November | 349979.36 | 52.44 | 09-NOV-10:35 | 26.17 |
| December | 1224864.31 | 144.33 | 23-DEC-07:00 | 6.10 |
| Annual Sum or Average | 14777544.36 | |||
| Minimum of Months | 0.00 | 0.00 | 6.10 | |
| Maximum of Months | 9389346.61 | 245.32 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 9449772.28 | 246.44 | 02-JAN-06:00 | 6.40 |
| February | 1110215.84 | 107.88 | 11-FEB-06:00 | 9.20 |
| March | 510482.23 | 58.18 | 28-MAR-09:15 | 26.40 |
| April | 959452.00 | 54.03 | 23-APR-08:45 | 25.78 |
| May | 13137.93 | 38.59 | 13-MAY-07:55 | 24.60 |
| June | 85348.41 | 41.05 | 18-JUN-06:55 | 24.80 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 141579.34 | 45.33 | 27-SEP-07:15 | 25.27 |
| October | 965705.16 | 55.09 | 15-OCT-08:55 | 26.10 |
| November | 348257.62 | 51.99 | 09-NOV-10:35 | 26.17 |
| December | 1184939.63 | 141.54 | 23-DEC-07:00 | 6.10 |
| Annual Sum or Average | 14768890.44 | |||
| Minimum of Months | 0.00 | 0.00 | 6.10 | |
| Maximum of Months | 9449772.28 | 246.44 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 7.83 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 9.73 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 15.55 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 23.70 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 30.53 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 17.72 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 12.50 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 7.83 | |
| Maximum of Months | 0.00 | 0.00 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 7.83 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 9.73 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 15.55 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 23.70 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 30.53 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 17.72 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 12.50 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 7.83 | |
| Maximum of Months | 0.00 | 0.00 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 7.83 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 9.73 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 15.55 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 23.70 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 30.53 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 17.72 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 12.50 |
| Annual Sum or Average | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 7.83 | |
| Maximum of Months | 0.00 | 0.00 | 32.95 |
Report: ZoneElectricSummaryMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.468251E+09 | 447.62 | 03-JAN-08:09 | 0.621586E+09 | 544.92 | 03-JAN-08:09 |
| February | 0.433623E+09 | 447.62 | 01-FEB-08:09 | 0.574385E+09 | 544.92 | 01-FEB-08:09 |
| March | 0.502522E+09 | 447.62 | 01-MAR-08:09 | 0.663122E+09 | 544.92 | 01-MAR-08:09 |
| April | 0.460516E+09 | 447.62 | 03-APR-07:10 | 0.610467E+09 | 544.92 | 03-APR-07:10 |
| May | 0.491098E+09 | 447.62 | 01-MAY-07:10 | 0.649277E+09 | 544.92 | 01-MAY-07:10 |
| June | 0.483363E+09 | 447.62 | 01-JUN-07:10 | 0.638158E+09 | 544.92 | 01-JUN-07:10 |
| July | 0.468251E+09 | 447.62 | 03-JUL-07:10 | 0.621586E+09 | 544.92 | 03-JUL-07:10 |
| August | 0.502522E+09 | 447.62 | 01-AUG-07:10 | 0.663122E+09 | 544.92 | 01-AUG-07:10 |
| September | 0.460516E+09 | 447.62 | 01-SEP-07:10 | 0.610467E+09 | 544.92 | 01-SEP-07:10 |
| October | 0.479675E+09 | 447.62 | 02-OCT-07:10 | 0.635432E+09 | 544.92 | 02-OCT-07:10 |
| November | 0.460516E+09 | 447.62 | 01-NOV-07:10 | 0.610467E+09 | 544.92 | 01-NOV-07:10 |
| December | 0.468251E+09 | 447.62 | 01-DEC-08:09 | 0.621586E+09 | 544.92 | 01-DEC-08:09 |
| Annual Sum or Average | 0.567911E+10 | 0.751966E+10 | ||||
| Minimum of Months | 0.433623E+09 | 447.62 | 0.574385E+09 | 544.92 | ||
| Maximum of Months | 0.502522E+09 | 447.62 | 0.663122E+09 | 544.92 |
Report: ZoneElectricSummaryMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 78005350.11 | 87.71 | 01-JAN-19:10 | 0.103725E+10 | 588.62 | 01-JAN-17:10 |
| February | 70456445.26 | 87.71 | 01-FEB-19:10 | 0.936871E+09 | 588.62 | 01-FEB-17:10 |
| March | 78005350.11 | 87.71 | 01-MAR-19:10 | 0.103725E+10 | 588.62 | 01-MAR-17:10 |
| April | 75489048.50 | 87.71 | 01-APR-18:10 | 0.100379E+10 | 588.62 | 01-APR-16:10 |
| May | 78005350.11 | 87.71 | 01-MAY-18:10 | 0.103725E+10 | 588.62 | 01-MAY-16:10 |
| June | 75489048.50 | 87.71 | 01-JUN-18:10 | 0.100379E+10 | 588.62 | 01-JUN-16:10 |
| July | 78005350.11 | 87.71 | 01-JUL-18:10 | 0.103725E+10 | 588.62 | 01-JUL-16:10 |
| August | 78005350.11 | 87.71 | 01-AUG-18:10 | 0.103725E+10 | 588.62 | 01-AUG-16:10 |
| September | 75489048.50 | 87.71 | 01-SEP-18:10 | 0.100379E+10 | 588.62 | 01-SEP-16:10 |
| October | 78005350.11 | 87.71 | 01-OCT-18:10 | 0.103725E+10 | 588.62 | 01-OCT-16:10 |
| November | 75489048.50 | 87.71 | 01-NOV-18:10 | 0.100379E+10 | 588.62 | 01-NOV-16:10 |
| December | 78005350.11 | 87.71 | 01-DEC-19:10 | 0.103725E+10 | 588.62 | 01-DEC-17:10 |
| Annual Sum or Average | 0.918450E+09 | 0.122128E+11 | ||||
| Minimum of Months | 70456445.26 | 87.71 | 0.936871E+09 | 588.62 | ||
| Maximum of Months | 78005350.11 | 87.71 | 0.103725E+10 | 588.62 |
Report: ZoneElectricSummaryMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
| January | 0.824800E+09 | 307.95 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.744981E+09 | 307.95 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.824800E+09 | 307.95 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.798194E+09 | 307.95 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.824800E+09 | 307.95 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.798194E+09 | 307.95 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 0.824800E+09 | 307.95 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 0.824800E+09 | 307.95 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 0.798194E+09 | 307.95 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 0.824800E+09 | 307.95 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.798194E+09 | 307.95 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.824800E+09 | 307.95 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.971136E+10 | 0.00 | 0.00 | ||
| Minimum of Months | 0.744981E+09 | 307.95 | 0.00 | 0.00 | |
| Maximum of Months | 0.824800E+09 | 307.95 | 0.00 | 0.00 |
Report: ZoneElectricSummaryMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
| January | 0.824800E+09 | 307.95 | 01-JAN-00:10 | 0.576651E+10 | 3803.87 | 01-JAN-07:10 |
| February | 0.744981E+09 | 307.95 | 01-FEB-00:10 | 0.520846E+10 | 3803.87 | 01-FEB-07:10 |
| March | 0.824800E+09 | 307.95 | 01-MAR-00:10 | 0.576651E+10 | 3803.87 | 01-MAR-07:10 |
| April | 0.798194E+09 | 307.95 | 01-APR-00:10 | 0.558049E+10 | 3803.87 | 01-APR-06:10 |
| May | 0.824800E+09 | 307.95 | 01-MAY-00:10 | 0.576651E+10 | 3803.87 | 01-MAY-06:10 |
| June | 0.798194E+09 | 307.95 | 01-JUN-00:10 | 0.558049E+10 | 3803.87 | 01-JUN-06:10 |
| July | 0.824800E+09 | 307.95 | 01-JUL-00:10 | 0.576651E+10 | 3803.87 | 01-JUL-06:10 |
| August | 0.824800E+09 | 307.95 | 01-AUG-00:10 | 0.576651E+10 | 3803.87 | 01-AUG-06:10 |
| September | 0.798194E+09 | 307.95 | 01-SEP-00:10 | 0.558049E+10 | 3803.87 | 01-SEP-06:10 |
| October | 0.824800E+09 | 307.95 | 01-OCT-00:10 | 0.576651E+10 | 3803.87 | 01-OCT-06:10 |
| November | 0.798194E+09 | 307.95 | 01-NOV-00:10 | 0.558049E+10 | 3803.87 | 01-NOV-06:10 |
| December | 0.824800E+09 | 307.95 | 01-DEC-00:10 | 0.576651E+10 | 3803.87 | 01-DEC-07:10 |
| Annual Sum or Average | 0.971136E+10 | 0.678960E+11 | ||||
| Minimum of Months | 0.744981E+09 | 307.95 | 0.520846E+10 | 3803.87 | ||
| Maximum of Months | 0.824800E+09 | 307.95 | 0.576651E+10 | 3803.87 |
Report: ZoneElectricSummaryMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
| January | 0.824800E+09 | 307.95 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 0.744981E+09 | 307.95 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 0.824800E+09 | 307.95 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 0.798194E+09 | 307.95 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 0.824800E+09 | 307.95 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 0.798194E+09 | 307.95 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 0.824800E+09 | 307.95 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 0.824800E+09 | 307.95 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 0.798194E+09 | 307.95 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 0.824800E+09 | 307.95 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 0.798194E+09 | 307.95 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 0.824800E+09 | 307.95 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.971136E+10 | 0.00 | 0.00 | ||
| Minimum of Months | 0.744981E+09 | 307.95 | 0.00 | 0.00 | |
| Maximum of Months | 0.824800E+09 | 307.95 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24899717.54 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 548392.42 | 24287135.37 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7551766.74 | 11062391.01 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 28807927.33 | 723999.84 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 50562331.10 | 71411.66 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36290526.90 | 33775.73 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 42295491.25 | 8721.83 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27717860.56 | 5270.69 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18387227.23 | 14897.67 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8927286.10 | 1246143.06 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2084794.44 | 5351036.84 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13213.97 | 20666702.60 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.223187E+09 | 88371203.83 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5270.69 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 50562331.10 | 24899717.54 |
Report: SpaceGainsMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21767549.11 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 536344.45 | 22406016.83 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7510267.62 | 10715801.47 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 28796304.92 | 705823.89 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 50562336.20 | 71398.22 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36290521.51 | 33845.16 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 42295489.60 | 8721.84 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27717858.70 | 5270.69 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18387212.62 | 14131.01 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8880511.06 | 1226295.97 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2043761.76 | 5186285.20 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11163.96 | 19545283.75 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.223032E+09 | 81686423.14 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5270.69 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 50562336.20 | 22406016.83 |
Report: SpaceGainsMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.227408E+09 | 0.468251E+09 | 0.621586E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24796510.61 |
| February | 0.216037E+09 | 0.433623E+09 | 0.574385E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 431337.94 | 26404579.26 |
| March | 0.261519E+09 | 0.502522E+09 | 0.663122E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4468032.90 | 16178046.98 |
| April | 0.227408E+09 | 0.460516E+09 | 0.610467E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 20139797.33 | 2853227.73 |
| May | 0.250148E+09 | 0.491098E+09 | 0.649277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 35347579.23 | 1745415.26 |
| June | 0.250148E+09 | 0.483363E+09 | 0.638158E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 26205081.73 | 1259734.26 |
| July | 0.227408E+09 | 0.468251E+09 | 0.621586E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 25082394.68 | 1191972.55 |
| August | 0.261519E+09 | 0.502522E+09 | 0.663122E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16786481.23 | 1644309.68 |
| September | 0.227408E+09 | 0.460516E+09 | 0.610467E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11913767.21 | 2394654.22 |
| October | 0.238778E+09 | 0.479675E+09 | 0.635432E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6086591.64 | 2399120.91 |
| November | 0.227408E+09 | 0.460516E+09 | 0.610467E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1340981.45 | 6480816.19 |
| December | 0.227408E+09 | 0.468251E+09 | 0.621586E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9288.52 | 20938798.33 |
| Annual Sum or Average | 0.284259E+10 | 0.567911E+10 | 0.751966E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.147811E+09 | 0.108287E+09 |
| Minimum of Months | 0.216037E+09 | 0.433623E+09 | 0.574385E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1191972.55 |
| Maximum of Months | 0.261519E+09 | 0.502522E+09 | 0.663122E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 35347579.23 | 26404579.26 |
Report: SpaceGainsMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21966120.69 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 535568.63 | 22775075.04 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7503136.69 | 10969328.63 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 28794721.89 | 738394.78 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 50562273.58 | 71253.65 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36290497.56 | 33567.49 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 42295493.97 | 8721.83 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27717862.17 | 5270.68 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18387120.56 | 13958.43 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8880073.05 | 1256809.71 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2043399.75 | 5316713.71 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11357.14 | 19666089.19 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.223022E+09 | 82821303.82 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5270.68 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 50562273.58 | 22775075.04 |
Report: SpaceGainsMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13688713.06 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 323582.93 | 14013944.69 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4528731.10 | 6557653.70 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17369217.73 | 439584.52 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30497867.68 | 43025.44 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21889491.14 | 19925.59 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25511572.93 | 5260.77 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16718714.41 | 3179.12 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11090566.14 | 7957.36 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5355750.92 | 735936.88 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1232816.33 | 3129732.78 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6998.00 | 11992003.12 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.134525E+09 | 50636917.04 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3179.12 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30497867.68 | 14013944.69 |
Report: SpaceGainsMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13699689.93 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 323589.89 | 14031626.46 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4528569.33 | 6562694.16 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17369174.20 | 439904.57 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30497867.87 | 43022.70 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21889491.48 | 19915.57 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25511573.23 | 5260.76 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16718714.70 | 3179.12 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11090566.45 | 7954.02 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5355760.86 | 736178.17 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1232780.04 | 3132535.45 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7010.33 | 11996288.96 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.134525E+09 | 50678249.87 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3179.12 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30497867.87 | 14031626.46 |
Report: SpaceGainsMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15238656.97 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 330596.71 | 14912429.39 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4554571.05 | 6775857.17 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17376240.10 | 452705.03 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30497867.39 | 43115.70 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21889491.53 | 19933.22 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25511574.63 | 5260.75 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16718716.11 | 3179.11 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11090573.36 | 8573.25 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5384275.31 | 753447.43 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1256694.58 | 3256473.74 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7899.72 | 12686864.15 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.134619E+09 | 54156495.91 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3179.11 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30497867.39 | 15238656.97 |
Report: SpaceGainsMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15234191.19 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 330643.46 | 14948194.81 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4554633.05 | 6824284.33 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17376077.44 | 469889.07 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30497853.39 | 44632.96 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21889483.62 | 21163.52 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25511575.32 | 5260.76 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16718716.60 | 3179.11 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11090591.33 | 9083.89 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5384176.38 | 775538.46 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1256692.30 | 3279039.27 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7912.74 | 12697700.22 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.134618E+09 | 54312157.60 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3179.11 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30497853.39 | 15234191.19 |
Report: SpaceGainsMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36347508.73 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 774825.45 | 35923422.08 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10790815.51 | 16441938.30 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 41296893.03 | 1073360.68 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 72513526.64 | 101806.75 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 52049813.64 | 44520.94 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60624412.99 | 12961.63 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39711191.94 | 8076.53 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26333634.24 | 16283.15 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12785882.24 | 1621019.71 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2976047.83 | 7552284.51 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17835.09 | 29513726.50 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.319875E+09 | 0.128657E+09 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8076.53 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 72513526.64 | 36347508.73 |
Report: SpaceGainsMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32048545.47 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 755470.67 | 34378779.88 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10723595.08 | 16168066.42 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 41279343.40 | 1057068.66 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 72513518.68 | 101665.87 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 52049813.36 | 44461.32 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60624410.12 | 12961.64 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39711188.82 | 8076.54 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26333643.84 | 14940.17 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12723100.32 | 1576546.99 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2921833.98 | 7138904.88 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17592.72 | 27295723.13 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.319654E+09 | 0.119846E+09 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8076.54 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 72513518.68 | 34378779.88 |
Report: SpaceGainsMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36480238.08 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 774649.65 | 36206306.97 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10790214.58 | 16739817.97 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 41296704.08 | 1112454.58 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 72513486.17 | 101753.94 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 52049822.70 | 44011.24 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60624419.58 | 12961.62 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39711196.84 | 8076.52 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26333621.18 | 16313.39 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12785644.05 | 1654672.70 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2975457.69 | 7684391.30 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17832.94 | 29711682.84 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.319873E+09 | 0.129773E+09 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8076.52 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 72513486.17 | 36480238.08 |
Report: SpaceGainsMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32401901.71 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 753829.61 | 34808342.32 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10721211.90 | 16604756.07 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 41278802.60 | 1108190.11 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 72513498.38 | 101502.71 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 52049822.56 | 43945.70 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60624416.85 | 12961.63 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39711193.91 | 8076.53 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26333630.57 | 14972.89 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12719484.25 | 1634816.14 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2917274.49 | 7326966.26 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15608.74 | 27551830.79 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.319639E+09 | 0.121618E+09 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8076.53 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 72513498.38 | 34808342.32 |
Report: SpaceGainsMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20257580.66 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 454758.09 | 20949144.94 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6468461.02 | 9743553.37 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24898828.21 | 639709.82 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43738261.77 | 60404.06 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31395042.66 | 26095.91 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36567118.20 | 7818.10 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23952791.47 | 4871.52 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15883805.95 | 8737.63 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7673825.48 | 964914.38 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1761264.49 | 4337576.00 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9018.96 | 17068209.64 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.192803E+09 | 74068616.04 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4871.52 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43738261.77 | 20949144.94 |
Report: SpaceGainsMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20276672.34 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 454683.99 | 20971944.25 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6468361.76 | 9753374.33 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24898809.58 | 640260.04 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43738261.29 | 60395.85 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31395042.85 | 26078.38 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36567118.31 | 7818.10 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23952791.54 | 4871.52 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15883806.11 | 8729.92 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7673737.64 | 965425.22 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1761168.02 | 4341169.99 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9029.99 | 17077383.08 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.192803E+09 | 74134123.02 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4871.52 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43738261.29 | 20971944.25 |
Report: SpaceGainsMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22262269.55 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 467096.17 | 21879876.18 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6508755.03 | 9960551.39 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24909375.68 | 651161.18 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43738260.87 | 60545.32 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31395045.15 | 26129.60 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36567120.39 | 7818.09 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23952793.61 | 4871.51 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15883757.98 | 9632.50 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7711862.78 | 995788.00 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1794490.09 | 4614853.46 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10714.98 | 18096991.83 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.192939E+09 | 78570488.62 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4871.51 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43738260.87 | 22262269.55 |
Report: SpaceGainsMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22267605.14 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 467066.73 | 21888950.18 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6508720.57 | 9965092.93 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24909373.40 | 651735.77 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43738260.38 | 60537.16 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31395045.39 | 26112.17 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36567120.52 | 7818.09 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23952793.56 | 4871.51 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15883757.72 | 9625.23 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7711860.51 | 995976.16 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1794452.70 | 4616786.99 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10707.85 | 18100908.59 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.192939E+09 | 78596019.94 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4871.51 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43738260.38 | 22267605.14 |
Report: SpaceGainsMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43735561.48 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 991607.26 | 43703876.27 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14113915.15 | 20959948.88 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 54361101.05 | 1291452.73 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 95527684.03 | 138023.51 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 68579766.69 | 57835.72 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79777086.85 | 18298.55 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 52208297.30 | 12012.12 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34595545.87 | 17496.97 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16800035.68 | 1955916.74 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3884037.41 | 9273134.50 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20820.95 | 34818823.36 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.420860E+09 | 0.155982E+09 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12012.12 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 95527684.03 | 43735561.48 |
Report: SpaceGainsMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36427902.16 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 973960.47 | 39980969.33 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14031804.47 | 20329163.79 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 54339123.11 | 1284238.73 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 95527666.17 | 137378.37 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 68579766.82 | 57863.52 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79777083.51 | 18298.56 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 52208293.30 | 12012.13 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34595594.93 | 16439.65 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16729770.75 | 1895349.46 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3850082.93 | 8123387.54 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31240.50 | 29707324.04 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.420644E+09 | 0.137990E+09 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12012.13 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 95527666.17 | 39980969.33 |
Report: SpaceGainsMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44467282.91 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 991267.58 | 44584820.77 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14112623.54 | 21602487.51 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 54359942.14 | 1376484.50 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 95527684.17 | 137646.78 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 68579783.46 | 57348.76 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79777101.30 | 18298.53 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 52208308.39 | 12012.09 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34595512.46 | 17703.38 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16799110.51 | 2030484.00 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3883034.42 | 9587409.52 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20814.42 | 35351796.50 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.420855E+09 | 0.159244E+09 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12012.09 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 95527684.17 | 44584820.77 |
Report: SpaceGainsMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36748488.19 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 972544.67 | 41118898.84 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14024882.03 | 21276151.62 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 54337178.19 | 1382030.39 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 95527681.02 | 137209.13 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 68579783.87 | 57375.44 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79777097.94 | 18298.54 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 52208304.05 | 12012.10 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34595534.29 | 16639.55 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16714582.70 | 2013556.99 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3812071.40 | 8575908.47 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25461.49 | 30114825.47 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.420575E+09 | 0.141471E+09 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12012.10 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 95527681.02 | 41118898.84 |
Report: SpaceGainsMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22269951.11 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 586275.52 | 24809668.05 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8462530.21 | 12515490.30 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32775725.53 | 813498.43 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57619752.67 | 83901.32 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 41365537.45 | 35959.70 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48119527.82 | 11037.19 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31490730.08 | 7245.36 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20867161.33 | 10494.87 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10086064.98 | 1194994.42 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2307745.32 | 5155248.95 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24483.07 | 18526713.97 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.253706E+09 | 85434203.68 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7245.36 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57619752.67 | 24809668.05 |
Report: SpaceGainsMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22302925.29 |
| February | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 586387.54 | 24876596.84 |
| March | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8462199.29 | 12543639.96 |
| April | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32775659.17 | 815253.42 |
| May | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57619750.27 | 83873.79 |
| June | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 41365536.48 | 35933.27 |
| July | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48119528.02 | 11037.19 |
| August | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31490730.34 | 7245.36 |
| September | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20867161.57 | 10478.54 |
| October | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10085569.18 | 1196505.36 |
| November | 0.421173E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2306142.77 | 5166457.14 |
| December | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23395.11 | 18546169.87 |
| Annual Sum or Average | 0.512427E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.253702E+09 | 85596116.03 |
| Minimum of Months | 0.393095E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7245.36 |
| Maximum of Months | 0.435212E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57619750.27 | 24876596.84 |
Report: SpaceGainsMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27493160.23 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 597918.22 | 27486604.10 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8513129.63 | 12919769.42 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32789178.33 | 816168.80 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57619750.60 | 84167.18 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 41365523.49 | 35940.80 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48119530.46 | 11037.19 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31490733.13 | 7245.35 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20867150.65 | 11203.12 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10133180.50 | 1230318.75 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2342443.44 | 5885771.97 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12604.65 | 22070341.82 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.253851E+09 | 98051728.71 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7245.35 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57619750.60 | 27493160.23 |
Report: SpaceGainsMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27531059.39 |
| February | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 597860.75 | 27518669.03 |
| March | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8513048.42 | 12934834.41 |
| April | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32789153.35 | 817365.41 |
| May | 0.424935E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57619748.26 | 84139.11 |
| June | 0.406980E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 41365522.55 | 35914.41 |
| July | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48119530.66 | 11037.19 |
| August | 0.418950E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31490733.29 | 7245.35 |
| September | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20867150.96 | 11187.49 |
| October | 0.430920E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10133190.18 | 1231093.12 |
| November | 0.418950E+09 | 75489048.50 | 0.100379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2342397.25 | 5892027.56 |
| December | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12600.20 | 22087990.40 |
| Annual Sum or Average | 0.505732E+10 | 0.918450E+09 | 0.122128E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.253851E+09 | 98162562.86 |
| Minimum of Months | 0.389025E+09 | 70456445.26 | 0.936871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7245.35 |
| Maximum of Months | 0.436905E+09 | 78005350.11 | 0.103725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57619748.26 | 27531059.39 |
Report: SpaceGainsMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7131270.01 |
| February | 0.657255E+09 | 0.744981E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6046.56 | 8090380.89 |
| March | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1117311.95 | 4704481.46 |
| April | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6350161.82 | 369526.57 |
| May | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11828220.29 | 119519.77 |
| June | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8560578.43 | 75517.25 |
| July | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8962006.58 | 22655.27 |
| August | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5505263.07 | 50369.36 |
| September | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3599534.90 | 95750.85 |
| October | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1764682.44 | 496042.52 |
| November | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 281242.26 | 1680869.68 |
| December | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1212.66 | 5937167.22 |
| Annual Sum or Average | 0.856778E+10 | 0.971136E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47976260.96 | 28773550.85 |
| Minimum of Months | 0.657255E+09 | 0.744981E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22655.27 |
| Maximum of Months | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11828220.29 | 8090380.89 |
Report: SpaceGainsMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.215388E+10 |
| February | 0.657255E+09 | 0.744981E+09 | 0.260423E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 61770.25 | 0.141891E+10 |
| March | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.129936E+09 | 0.776944E+09 |
| April | 0.704201E+09 | 0.798194E+09 | 0.279025E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.692773E+09 | 0.196984E+09 |
| May | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118946E+10 | 32505542.08 |
| June | 0.704201E+09 | 0.798194E+09 | 0.279025E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.116739E+10 | 24047728.70 |
| July | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.755379E+09 | 15777554.01 |
| August | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.503760E+09 | 47432166.36 |
| September | 0.704201E+09 | 0.798194E+09 | 0.279025E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.382356E+09 | 0.118745E+09 |
| October | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.244280E+09 | 0.511360E+09 |
| November | 0.704201E+09 | 0.798194E+09 | 0.279025E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 18090585.50 | 0.116275E+10 |
| December | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.205698E+10 |
| Annual Sum or Average | 0.856778E+10 | 0.971136E+10 | 0.339480E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.508349E+10 | 0.851631E+10 |
| Minimum of Months | 0.657255E+09 | 0.744981E+09 | 0.260423E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15777554.01 |
| Maximum of Months | 0.727675E+09 | 0.824800E+09 | 0.288326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118946E+10 | 0.215388E+10 |
Report: SpaceGainsMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
| January | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6742969.25 |
| February | 0.657255E+09 | 0.744981E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3631.85 | 7266918.60 |
| March | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 919015.43 | 3963913.56 |
| April | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5165084.99 | 333907.84 |
| May | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9578329.16 | 96242.08 |
| June | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6968448.69 | 59019.13 |
| July | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7461067.37 | 18068.86 |
| August | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4607669.84 | 30345.28 |
| September | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2975299.72 | 71409.06 |
| October | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1413950.41 | 426258.47 |
| November | 0.704201E+09 | 0.798194E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 190435.78 | 1567552.03 |
| December | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5671695.27 |
| Annual Sum or Average | 0.856778E+10 | 0.971136E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39282933.24 | 26248299.43 |
| Minimum of Months | 0.657255E+09 | 0.744981E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18068.86 |
| Maximum of Months | 0.727675E+09 | 0.824800E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9578329.16 | 7266918.60 |
Report: PeakSpaceGainsMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 48.52 | 31-JAN-08:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 7.68 | 19-FEB-15:00 | 58.27 | 18-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.24 | 27-MAR-15:00 | 76.68 | 24-MAR-24:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 97.76 | 15-APR-14:00 | 15.49 | 22-APR-18:30 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 101.42 | 05-MAY-15:00 | 4.79 | 13-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 105.34 | 06-JUN-15:00 | 4.65 | 18-JUN-05:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.46 | 19-JUL-12:00 | 1.72 | 19-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.38 | 31-AUG-11:00 | 1.35 | 15-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.06 | 19-SEP-13:00 | 2.52 | 27-SEP-06:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.54 | 03-OCT-15:00 | 10.25 | 23-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 17.60 | 13-NOV-14:00 | 20.56 | 28-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1.60 | 24-DEC-14:35 | 48.99 | 29-DEC-22:50 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.35 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 105.34 | 76.68 |
Report: PeakSpaceGainsMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 45.03 | 31-JAN-08:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 7.68 | 19-FEB-15:00 | 56.76 | 18-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.24 | 27-MAR-15:00 | 76.68 | 24-MAR-24:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 97.76 | 15-APR-14:00 | 14.26 | 22-APR-18:20 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 101.42 | 05-MAY-15:00 | 4.80 | 13-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 105.34 | 06-JUN-15:00 | 4.66 | 18-JUN-05:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.46 | 19-JUL-12:00 | 1.72 | 19-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.38 | 31-AUG-11:00 | 1.35 | 15-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.06 | 19-SEP-13:00 | 2.31 | 27-SEP-06:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.54 | 03-OCT-15:00 | 9.38 | 11-OCT-16:50 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 17.60 | 13-NOV-14:00 | 20.56 | 28-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1.73 | 28-DEC-14:00 | 48.46 | 29-DEC-24:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.35 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 105.34 | 76.68 |
Report: PeakSpaceGainsMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 451.21 | 03-JAN-08:09 | 447.62 | 03-JAN-08:09 | 544.92 | 03-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 47.74 | 31-JAN-08:10 |
| February | 451.21 | 01-FEB-08:09 | 447.62 | 01-FEB-08:09 | 544.92 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 6.87 | 21-FEB-15:00 | 59.60 | 18-FEB-08:00 |
| March | 451.21 | 01-MAR-08:09 | 447.62 | 01-MAR-08:09 | 544.92 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 38.24 | 27-MAR-15:00 | 111.56 | 24-MAR-24:00 |
| April | 451.21 | 03-APR-07:10 | 447.62 | 03-APR-07:10 | 544.92 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.21 | 27-APR-15:00 | 28.03 | 22-APR-18:00 |
| May | 451.21 | 01-MAY-07:10 | 447.62 | 01-MAY-07:10 | 544.92 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 101.42 | 05-MAY-15:00 | 16.82 | 15-MAY-03:00 |
| June | 451.21 | 01-JUN-07:10 | 447.62 | 01-JUN-07:10 | 544.92 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 105.34 | 06-JUN-15:00 | 22.84 | 24-JUN-11:00 |
| July | 451.21 | 03-JUL-07:10 | 447.62 | 03-JUL-07:10 | 544.92 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.46 | 19-JUL-12:00 | 12.72 | 26-JUL-06:00 |
| August | 451.21 | 01-AUG-07:10 | 447.62 | 01-AUG-07:10 | 544.92 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.38 | 31-AUG-11:00 | 12.74 | 15-AUG-23:00 |
| September | 451.21 | 01-SEP-07:10 | 447.62 | 01-SEP-07:10 | 544.92 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.06 | 19-SEP-13:00 | 9.33 | 08-SEP-21:00 |
| October | 451.21 | 02-OCT-07:10 | 447.62 | 02-OCT-07:10 | 544.92 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.54 | 03-OCT-15:00 | 18.11 | 12-OCT-03:00 |
| November | 451.21 | 01-NOV-07:10 | 447.62 | 01-NOV-07:10 | 544.92 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 11.90 | 10-NOV-14:00 | 25.25 | 28-NOV-05:00 |
| December | 451.21 | 01-DEC-08:09 | 447.62 | 01-DEC-08:09 | 544.92 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1.58 | 28-DEC-14:00 | 54.14 | 29-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 451.21 | 447.62 | 544.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.33 | |||||
| Maximum of Months | 451.21 | 447.62 | 544.92 | 0.00 | 0.00 | 0.00 | 0.00 | 105.34 | 111.56 |
Report: PeakSpaceGainsMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 45.50 | 31-JAN-08:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 7.68 | 19-FEB-15:00 | 57.45 | 18-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.24 | 27-MAR-15:00 | 76.68 | 24-MAR-24:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 97.76 | 15-APR-14:00 | 14.94 | 22-APR-18:40 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 101.42 | 05-MAY-15:00 | 4.78 | 13-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 105.34 | 06-JUN-15:00 | 4.60 | 18-JUN-05:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.46 | 19-JUL-12:00 | 1.72 | 19-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.38 | 31-AUG-11:00 | 1.35 | 15-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.06 | 19-SEP-13:00 | 2.31 | 27-SEP-06:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.54 | 03-OCT-15:00 | 9.39 | 11-OCT-16:50 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 17.60 | 13-NOV-14:00 | 20.56 | 28-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1.86 | 24-DEC-14:35 | 48.46 | 29-DEC-24:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.35 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 105.34 | 76.68 |
Report: PeakSpaceGainsMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 28.66 | 31-JAN-08:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4.63 | 19-FEB-15:00 | 35.15 | 18-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.07 | 27-MAR-15:00 | 46.25 | 24-MAR-24:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.97 | 15-APR-14:00 | 9.07 | 22-APR-18:40 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.17 | 05-MAY-15:00 | 2.90 | 13-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 63.54 | 06-JUN-15:00 | 2.69 | 18-JUN-05:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.07 | 19-JUL-12:00 | 1.04 | 19-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.77 | 31-AUG-11:00 | 0.82 | 15-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 27.18 | 19-SEP-13:00 | 1.27 | 27-SEP-06:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 29.28 | 03-OCT-15:00 | 5.37 | 11-OCT-16:50 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.61 | 13-NOV-14:00 | 12.40 | 28-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1.20 | 24-DEC-14:35 | 29.45 | 29-DEC-22:50 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.82 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 63.54 | 46.25 |
Report: PeakSpaceGainsMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 28.67 | 31-JAN-08:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4.63 | 19-FEB-15:00 | 35.15 | 18-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.07 | 27-MAR-15:00 | 46.25 | 24-MAR-24:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.97 | 15-APR-14:00 | 9.09 | 22-APR-18:40 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.17 | 05-MAY-15:00 | 2.90 | 13-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 63.54 | 06-JUN-15:00 | 2.69 | 18-JUN-05:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.07 | 19-JUL-12:00 | 1.04 | 19-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.77 | 31-AUG-11:00 | 0.82 | 15-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 27.18 | 19-SEP-13:00 | 1.26 | 27-SEP-06:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 29.28 | 03-OCT-15:00 | 5.37 | 11-OCT-16:50 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.61 | 13-NOV-14:00 | 12.40 | 28-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1.22 | 24-DEC-14:35 | 29.45 | 29-DEC-22:50 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.82 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 63.54 | 46.25 |
Report: PeakSpaceGainsMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 30.05 | 31-JAN-08:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4.63 | 19-FEB-15:00 | 35.15 | 18-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.07 | 27-MAR-15:00 | 46.25 | 24-MAR-24:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.97 | 15-APR-14:00 | 9.80 | 22-APR-18:30 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.17 | 05-MAY-15:00 | 2.91 | 13-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 63.54 | 06-JUN-15:00 | 2.69 | 18-JUN-05:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.07 | 19-JUL-12:00 | 1.04 | 19-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.77 | 31-AUG-11:00 | 0.82 | 15-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 27.18 | 19-SEP-13:00 | 1.42 | 27-SEP-06:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 29.28 | 03-OCT-15:00 | 6.30 | 23-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.61 | 13-NOV-14:00 | 12.40 | 28-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.95 | 28-DEC-14:00 | 34.94 | 29-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.82 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 63.54 | 46.25 |
Report: PeakSpaceGainsMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 30.05 | 31-JAN-08:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4.63 | 19-FEB-15:00 | 35.15 | 18-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.07 | 27-MAR-15:00 | 46.25 | 24-MAR-24:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.97 | 15-APR-14:00 | 10.24 | 22-APR-18:20 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.17 | 05-MAY-15:00 | 3.09 | 13-MAY-06:10 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 63.54 | 06-JUN-15:00 | 2.94 | 18-JUN-05:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.07 | 19-JUL-12:00 | 1.04 | 19-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.77 | 31-AUG-11:00 | 0.82 | 15-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 27.18 | 19-SEP-13:00 | 1.54 | 27-SEP-06:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 29.28 | 03-OCT-15:00 | 6.56 | 23-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.61 | 13-NOV-14:00 | 12.40 | 28-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.95 | 28-DEC-14:00 | 35.02 | 29-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.82 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 63.54 | 46.25 |
Report: PeakSpaceGainsMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 69.62 | 31-JAN-08:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.93 | 19-FEB-15:00 | 83.87 | 18-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 54.84 | 27-MAR-15:00 | 110.67 | 24-MAR-24:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 140.32 | 15-APR-14:00 | 22.61 | 22-APR-18:30 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 145.59 | 05-MAY-15:00 | 6.65 | 13-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 151.23 | 06-JUN-15:00 | 5.87 | 18-JUN-05:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 88.13 | 19-JUL-12:00 | 2.53 | 19-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 63.61 | 31-AUG-11:00 | 2.01 | 15-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.61 | 19-SEP-13:00 | 2.47 | 27-SEP-06:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 69.63 | 03-OCT-15:00 | 12.42 | 11-OCT-18:10 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 25.17 | 13-NOV-14:00 | 29.62 | 28-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2.20 | 28-DEC-14:00 | 69.79 | 29-DEC-24:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.01 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 151.23 | 110.67 |
Report: PeakSpaceGainsMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 64.91 | 31-JAN-08:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.93 | 19-FEB-15:00 | 83.87 | 18-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 54.84 | 27-MAR-15:00 | 110.67 | 24-MAR-24:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 140.32 | 15-APR-14:00 | 20.62 | 22-APR-18:20 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 145.59 | 05-MAY-15:00 | 6.66 | 13-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 151.23 | 06-JUN-15:00 | 5.86 | 18-JUN-05:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 88.13 | 19-JUL-12:00 | 2.53 | 19-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 63.61 | 31-AUG-11:00 | 2.01 | 15-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.61 | 19-SEP-13:00 | 2.21 | 27-SEP-06:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 69.63 | 03-OCT-15:00 | 12.08 | 11-OCT-16:50 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 25.17 | 13-NOV-14:00 | 29.62 | 28-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3.32 | 28-DEC-13:44 | 69.79 | 29-DEC-24:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.01 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 151.23 | 110.67 |
Report: PeakSpaceGainsMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 70.32 | 31-JAN-08:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.93 | 19-FEB-15:00 | 83.87 | 18-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 54.84 | 27-MAR-15:00 | 110.67 | 24-MAR-24:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 140.32 | 15-APR-14:00 | 23.17 | 22-APR-18:30 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 145.59 | 05-MAY-15:00 | 6.62 | 13-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 151.23 | 06-JUN-15:00 | 5.78 | 18-JUN-05:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 88.13 | 19-JUL-12:00 | 2.53 | 19-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 63.61 | 31-AUG-11:00 | 2.01 | 15-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.61 | 19-SEP-13:00 | 2.53 | 27-SEP-07:00 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 69.63 | 03-OCT-15:00 | 12.59 | 23-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 25.17 | 13-NOV-14:00 | 29.62 | 28-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2.20 | 28-DEC-14:00 | 69.79 | 29-DEC-24:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.01 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 151.23 | 110.67 |
Report: PeakSpaceGainsMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 65.69 | 31-JAN-08:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.93 | 19-FEB-15:00 | 83.87 | 18-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 54.84 | 27-MAR-15:00 | 110.67 | 24-MAR-24:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 140.32 | 15-APR-14:00 | 21.94 | 22-APR-18:40 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 145.59 | 05-MAY-15:00 | 6.63 | 13-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 151.23 | 06-JUN-15:00 | 5.77 | 18-JUN-05:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 88.13 | 19-JUL-12:00 | 2.53 | 19-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 63.61 | 31-AUG-11:00 | 2.01 | 15-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.61 | 19-SEP-13:00 | 2.25 | 27-SEP-06:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 69.63 | 03-OCT-15:00 | 12.07 | 11-OCT-16:50 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 25.17 | 13-NOV-14:00 | 29.62 | 28-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2.52 | 28-DEC-13:44 | 69.79 | 29-DEC-24:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.01 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 151.23 | 110.67 |
Report: PeakSpaceGainsMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 41.65 | 31-JAN-08:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6.59 | 19-FEB-15:00 | 50.59 | 18-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 33.08 | 27-MAR-15:00 | 66.76 | 24-MAR-24:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 84.64 | 15-APR-14:00 | 12.52 | 22-APR-18:20 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 87.82 | 05-MAY-15:00 | 3.96 | 13-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 91.22 | 06-JUN-15:00 | 3.40 | 18-JUN-05:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 53.16 | 19-JUL-12:00 | 1.53 | 19-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.37 | 31-AUG-11:00 | 1.21 | 15-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.97 | 19-SEP-13:00 | 1.28 | 27-SEP-06:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 42.00 | 03-OCT-15:00 | 7.23 | 24-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 15.18 | 13-NOV-14:00 | 17.86 | 28-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1.36 | 24-DEC-14:35 | 42.09 | 29-DEC-24:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.21 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 91.22 | 66.76 |
Report: PeakSpaceGainsMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 41.67 | 31-JAN-08:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6.59 | 19-FEB-15:00 | 50.59 | 18-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 33.08 | 27-MAR-15:00 | 66.76 | 24-MAR-24:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 84.64 | 15-APR-14:00 | 12.54 | 22-APR-18:20 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 87.82 | 05-MAY-15:00 | 3.96 | 13-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 91.22 | 06-JUN-15:00 | 3.40 | 18-JUN-05:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 53.16 | 19-JUL-12:00 | 1.53 | 19-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.37 | 31-AUG-11:00 | 1.21 | 15-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.97 | 19-SEP-13:00 | 1.28 | 27-SEP-06:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 42.00 | 03-OCT-15:00 | 7.23 | 24-OCT-07:00 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 15.18 | 13-NOV-14:00 | 17.86 | 28-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1.39 | 24-DEC-14:35 | 42.09 | 29-DEC-24:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.21 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 91.22 | 66.76 |
Report: PeakSpaceGainsMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 43.24 | 31-JAN-08:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6.59 | 19-FEB-15:00 | 50.59 | 18-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 33.08 | 27-MAR-15:00 | 66.75 | 24-MAR-24:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 84.64 | 15-APR-14:00 | 13.74 | 22-APR-18:30 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 87.82 | 05-MAY-15:00 | 3.95 | 13-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 91.22 | 06-JUN-15:00 | 3.40 | 18-JUN-05:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 53.16 | 19-JUL-12:00 | 1.53 | 19-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.37 | 31-AUG-11:00 | 1.21 | 15-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.97 | 19-SEP-13:00 | 1.45 | 27-SEP-06:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 42.00 | 03-OCT-15:00 | 7.55 | 23-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 15.18 | 13-NOV-14:00 | 17.86 | 28-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 28-DEC-14:00 | 43.31 | 29-DEC-22:50 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.21 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 91.22 | 66.75 |
Report: PeakSpaceGainsMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 43.24 | 31-JAN-08:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6.59 | 19-FEB-15:00 | 50.59 | 18-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 33.08 | 27-MAR-15:00 | 66.75 | 24-MAR-24:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 84.64 | 15-APR-14:00 | 13.76 | 22-APR-18:30 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 87.82 | 05-MAY-15:00 | 3.95 | 13-MAY-06:00 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 91.22 | 06-JUN-15:00 | 3.40 | 18-JUN-05:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 53.16 | 19-JUL-12:00 | 1.53 | 19-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.37 | 31-AUG-11:00 | 1.21 | 15-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.97 | 19-SEP-13:00 | 1.45 | 27-SEP-06:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 42.00 | 03-OCT-15:00 | 7.55 | 23-OCT-08:00 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 15.18 | 13-NOV-14:00 | 17.86 | 28-NOV-06:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 28-DEC-14:00 | 43.31 | 29-DEC-22:50 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.21 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 91.22 | 66.75 |
Report: PeakSpaceGainsMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 78.41 | 31-JAN-08:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.17 | 19-FEB-15:00 | 97.87 | 18-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 72.23 | 27-MAR-15:00 | 147.65 | 24-MAR-24:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 185.16 | 15-APR-14:00 | 28.12 | 22-APR-19:00 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 192.19 | 05-MAY-15:00 | 8.50 | 13-MAY-06:10 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 199.66 | 06-JUN-15:00 | 6.95 | 18-JUN-05:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 116.05 | 19-JUL-12:00 | 3.51 | 19-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.70 | 31-AUG-11:00 | 2.82 | 15-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 85.06 | 19-SEP-13:00 | 2.55 | 27-SEP-06:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 91.79 | 03-OCT-15:00 | 19.30 | 11-OCT-16:40 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 32.98 | 13-NOV-14:00 | 36.78 | 28-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2.71 | 28-DEC-14:00 | 80.33 | 29-DEC-24:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.55 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 199.66 | 147.65 |
Report: PeakSpaceGainsMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 78.41 | 31-JAN-08:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.17 | 19-FEB-15:00 | 92.69 | 18-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 72.23 | 27-MAR-15:00 | 147.65 | 24-MAR-24:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 185.16 | 15-APR-14:00 | 26.56 | 22-APR-18:30 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 192.19 | 05-MAY-15:00 | 8.51 | 13-MAY-06:10 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 199.66 | 06-JUN-15:00 | 6.97 | 18-JUN-05:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 116.05 | 19-JUL-12:00 | 3.51 | 19-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.70 | 31-AUG-11:00 | 2.82 | 15-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 85.06 | 19-SEP-13:00 | 2.34 | 27-SEP-06:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 91.79 | 03-OCT-15:00 | 19.19 | 11-OCT-16:50 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 32.98 | 13-NOV-14:00 | 35.45 | 29-NOV-24:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4.93 | 24-DEC-13:52 | 78.08 | 29-DEC-24:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.34 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 199.66 | 147.65 |
Report: PeakSpaceGainsMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 78.41 | 31-JAN-08:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.17 | 19-FEB-15:00 | 99.66 | 18-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 72.23 | 27-MAR-15:00 | 147.65 | 24-MAR-24:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 185.16 | 15-APR-14:00 | 30.21 | 22-APR-18:50 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 192.19 | 05-MAY-15:00 | 8.44 | 13-MAY-06:10 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 199.66 | 06-JUN-15:00 | 6.87 | 18-JUN-05:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 116.05 | 19-JUL-12:00 | 3.51 | 19-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.70 | 31-AUG-11:00 | 2.82 | 15-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 85.06 | 19-SEP-13:00 | 2.72 | 27-SEP-07:00 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 91.79 | 03-OCT-15:00 | 19.16 | 11-OCT-16:40 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 32.98 | 13-NOV-14:00 | 36.64 | 28-NOV-05:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2.71 | 28-DEC-14:00 | 80.23 | 29-DEC-24:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.72 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 199.66 | 147.65 |
Report: PeakSpaceGainsMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 78.41 | 31-JAN-08:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.17 | 19-FEB-15:00 | 94.40 | 18-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 72.23 | 27-MAR-15:00 | 147.65 | 24-MAR-24:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 185.16 | 15-APR-14:00 | 27.15 | 22-APR-18:30 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 192.19 | 05-MAY-15:00 | 8.45 | 13-MAY-06:10 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 199.66 | 06-JUN-15:00 | 6.88 | 18-JUN-05:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 116.05 | 19-JUL-12:00 | 3.51 | 19-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.70 | 31-AUG-11:00 | 2.82 | 15-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 85.06 | 19-SEP-13:00 | 2.47 | 27-SEP-07:00 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 91.79 | 03-OCT-15:00 | 19.05 | 11-OCT-16:50 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 32.98 | 13-NOV-14:00 | 35.45 | 29-NOV-24:00 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4.97 | 28-DEC-13:46 | 77.74 | 29-DEC-24:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.47 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 199.66 | 147.65 |
Report: PeakSpaceGainsMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 47.29 | 31-JAN-08:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8.54 | 19-FEB-15:00 | 60.50 | 18-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 43.57 | 27-MAR-15:00 | 89.06 | 24-MAR-24:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 111.68 | 15-APR-14:00 | 17.67 | 22-APR-18:50 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 115.92 | 05-MAY-15:00 | 5.26 | 13-MAY-06:10 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.43 | 06-JUN-15:00 | 4.32 | 18-JUN-05:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 70.00 | 19-JUL-12:00 | 2.12 | 19-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.49 | 31-AUG-11:00 | 1.70 | 15-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.30 | 19-SEP-13:00 | 1.53 | 27-SEP-06:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 55.37 | 03-OCT-15:00 | 11.14 | 11-OCT-17:00 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.89 | 13-NOV-14:00 | 22.40 | 28-NOV-05:30 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3.45 | 24-DEC-13:52 | 51.42 | 29-DEC-24:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.53 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 120.43 | 89.06 |
Report: PeakSpaceGainsMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 47.29 | 31-JAN-08:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8.54 | 19-FEB-15:00 | 60.52 | 18-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 43.57 | 27-MAR-15:00 | 89.06 | 24-MAR-24:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 111.68 | 15-APR-14:00 | 17.70 | 22-APR-18:50 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 115.92 | 05-MAY-15:00 | 5.26 | 13-MAY-06:10 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.43 | 06-JUN-15:00 | 4.31 | 18-JUN-05:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 70.00 | 19-JUL-12:00 | 2.12 | 19-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.49 | 31-AUG-11:00 | 1.70 | 15-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.30 | 19-SEP-13:00 | 1.53 | 27-SEP-06:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 55.37 | 03-OCT-15:00 | 11.14 | 11-OCT-17:00 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.89 | 13-NOV-14:00 | 22.38 | 28-NOV-05:30 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3.29 | 24-DEC-13:52 | 51.37 | 29-DEC-24:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.53 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 120.43 | 89.06 |
Report: PeakSpaceGainsMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 47.72 | 31-JAN-08:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8.54 | 19-FEB-15:00 | 63.90 | 18-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 43.57 | 27-MAR-15:00 | 89.06 | 24-MAR-24:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 111.68 | 15-APR-14:00 | 19.18 | 22-APR-18:40 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 115.92 | 05-MAY-15:00 | 5.26 | 13-MAY-06:10 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.43 | 06-JUN-15:00 | 4.31 | 18-JUN-05:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 70.00 | 19-JUL-12:00 | 2.12 | 19-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.49 | 31-AUG-11:00 | 1.70 | 15-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.30 | 19-SEP-13:00 | 1.67 | 27-SEP-06:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 55.37 | 03-OCT-15:00 | 11.13 | 11-OCT-18:10 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.89 | 13-NOV-14:00 | 23.71 | 28-NOV-05:30 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1.64 | 28-DEC-14:00 | 53.04 | 29-DEC-24:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 120.43 | 89.06 |
Report: PeakSpaceGainsMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 237.50 | 01-JAN-00:10 | 87.71 | 01-JAN-19:10 | 588.62 | 01-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 47.72 | 31-JAN-08:00 |
| February | 237.50 | 01-FEB-00:10 | 87.71 | 01-FEB-19:10 | 588.62 | 01-FEB-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8.54 | 19-FEB-15:00 | 63.91 | 18-FEB-08:00 |
| March | 237.50 | 01-MAR-00:10 | 87.71 | 01-MAR-19:10 | 588.62 | 01-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 43.57 | 27-MAR-15:00 | 89.06 | 24-MAR-24:00 |
| April | 237.50 | 01-APR-00:10 | 87.71 | 01-APR-18:10 | 588.62 | 01-APR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 111.68 | 15-APR-14:00 | 19.21 | 22-APR-18:40 |
| May | 237.50 | 01-MAY-00:10 | 87.71 | 01-MAY-18:10 | 588.62 | 01-MAY-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 115.92 | 05-MAY-15:00 | 5.26 | 13-MAY-06:10 |
| June | 237.50 | 01-JUN-00:10 | 87.71 | 01-JUN-18:10 | 588.62 | 01-JUN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.43 | 06-JUN-15:00 | 4.30 | 18-JUN-05:30 |
| July | 237.50 | 01-JUL-00:10 | 87.71 | 01-JUL-18:10 | 588.62 | 01-JUL-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 70.00 | 19-JUL-12:00 | 2.12 | 19-JUL-03:00 |
| August | 237.50 | 01-AUG-00:10 | 87.71 | 01-AUG-18:10 | 588.62 | 01-AUG-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.49 | 31-AUG-11:00 | 1.70 | 15-AUG-24:00 |
| September | 237.50 | 01-SEP-00:10 | 87.71 | 01-SEP-18:10 | 588.62 | 01-SEP-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.30 | 19-SEP-13:00 | 1.67 | 27-SEP-06:50 |
| October | 237.50 | 01-OCT-00:10 | 87.71 | 01-OCT-18:10 | 588.62 | 01-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 55.37 | 03-OCT-15:00 | 11.13 | 11-OCT-18:10 |
| November | 237.50 | 01-NOV-00:10 | 87.71 | 01-NOV-18:10 | 588.62 | 01-NOV-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.89 | 13-NOV-14:00 | 23.70 | 28-NOV-05:30 |
| December | 237.50 | 01-DEC-00:10 | 87.71 | 01-DEC-19:10 | 588.62 | 01-DEC-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1.64 | 28-DEC-14:00 | 53.03 | 29-DEC-24:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | |||||
| Maximum of Months | 237.50 | 87.71 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 120.43 | 89.06 |
Report: PeakSpaceGainsMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 13.74 | 31-JAN-08:00 |
| February | 397.10 | 01-FEB-00:10 | 307.95 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.37 | 22-FEB-15:00 | 18.45 | 18-FEB-08:00 |
| March | 397.10 | 01-MAR-00:10 | 307.95 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.79 | 27-MAR-15:00 | 33.69 | 24-MAR-24:00 |
| April | 397.10 | 01-APR-00:10 | 307.95 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.47 | 15-APR-14:00 | 5.24 | 22-APR-18:10 |
| May | 397.10 | 01-MAY-00:10 | 307.95 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.88 | 05-MAY-15:00 | 1.95 | 13-MAY-05:00 |
| June | 397.10 | 01-JUN-00:10 | 307.95 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.98 | 06-JUN-15:00 | 2.10 | 18-JUN-05:00 |
| July | 397.10 | 01-JUL-00:10 | 307.95 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.19 | 19-JUL-11:00 | 1.76 | 19-JUL-03:00 |
| August | 397.10 | 01-AUG-00:10 | 307.95 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.48 | 31-AUG-11:00 | 2.22 | 15-AUG-24:00 |
| September | 397.10 | 01-SEP-00:10 | 307.95 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.04 | 19-SEP-13:00 | 1.46 | 08-SEP-21:00 |
| October | 397.10 | 01-OCT-00:10 | 307.95 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.77 | 03-OCT-14:00 | 4.19 | 12-OCT-03:00 |
| November | 397.10 | 01-NOV-00:10 | 307.95 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.89 | 13-NOV-14:00 | 7.33 | 29-NOV-24:00 |
| December | 397.10 | 01-DEC-00:10 | 307.95 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.56 | 24-DEC-13:52 | 15.73 | 29-DEC-18:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.46 | ||||
| Maximum of Months | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.98 | 33.69 |
Report: PeakSpaceGainsMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 | 190.19 | 01-JAN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 10369.92 | 21-JAN-07:01 |
| February | 397.10 | 01-FEB-00:10 | 307.95 | 01-FEB-00:10 | 190.19 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.99 | 22-FEB-15:00 | 9490.96 | 02-FEB-07:01 |
| March | 397.10 | 01-MAR-00:10 | 307.95 | 01-MAR-00:10 | 190.19 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3679.66 | 28-MAR-16:02 | 6175.92 | 01-MAR-07:01 |
| April | 397.10 | 01-APR-00:10 | 307.95 | 01-APR-00:10 | 190.19 | 01-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 5466.74 | 27-APR-16:01 | 4100.79 | 11-APR-06:01 |
| May | 397.10 | 01-MAY-00:10 | 307.95 | 01-MAY-00:10 | 190.19 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 7347.27 | 03-MAY-16:01 | 2050.97 | 13-MAY-06:03 |
| June | 397.10 | 01-JUN-00:10 | 307.95 | 01-JUN-00:10 | 190.19 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 7357.83 | 08-JUN-16:01 | 1894.57 | 18-JUN-06:03 |
| July | 397.10 | 01-JUL-00:10 | 307.95 | 01-JUL-00:10 | 190.19 | 01-JUL-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 5435.74 | 02-JUL-16:01 | 923.52 | 26-JUL-06:01 |
| August | 397.10 | 01-AUG-00:10 | 307.95 | 01-AUG-00:10 | 190.19 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3936.28 | 07-AUG-16:01 | 1707.77 | 16-AUG-06:01 |
| September | 397.10 | 01-SEP-00:10 | 307.95 | 01-SEP-00:10 | 190.19 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3414.74 | 26-SEP-16:01 | 2148.93 | 27-SEP-06:01 |
| October | 397.10 | 01-OCT-00:10 | 307.95 | 01-OCT-00:10 | 190.19 | 01-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3446.77 | 02-OCT-16:01 | 5704.35 | 31-OCT-06:01 |
| November | 397.10 | 01-NOV-00:10 | 307.95 | 01-NOV-00:10 | 190.19 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 611.86 | 04-NOV-16:05 | 8592.65 | 27-NOV-07:01 |
| December | 397.10 | 01-DEC-00:10 | 307.95 | 01-DEC-00:10 | 190.19 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 10603.96 | 31-DEC-07:01 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 397.10 | 307.95 | 190.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 923.52 | |||||
| Maximum of Months | 397.10 | 307.95 | 190.19 | 0.00 | 0.00 | 0.00 | 0.00 | 7357.83 | 10603.96 |
Report: PeakSpaceGainsMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
| January | 397.10 | 01-JAN-00:10 | 307.95 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 12.99 | 31-JAN-08:00 |
| February | 397.10 | 01-FEB-00:10 | 307.95 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.32 | 22-FEB-15:00 | 16.53 | 18-FEB-08:00 |
| March | 397.10 | 01-MAR-00:10 | 307.95 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.16 | 27-MAR-15:00 | 27.55 | 24-MAR-24:00 |
| April | 397.10 | 01-APR-00:10 | 307.95 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.64 | 15-APR-14:00 | 4.19 | 22-APR-18:10 |
| May | 397.10 | 01-MAY-00:10 | 307.95 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.76 | 05-MAY-15:00 | 1.57 | 13-MAY-05:00 |
| June | 397.10 | 01-JUN-00:10 | 307.95 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.74 | 06-JUN-15:00 | 1.72 | 18-JUN-05:00 |
| July | 397.10 | 01-JUL-00:10 | 307.95 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.77 | 20-JUL-15:00 | 1.42 | 19-JUL-03:00 |
| August | 397.10 | 01-AUG-00:10 | 307.95 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.76 | 31-AUG-11:00 | 1.53 | 15-AUG-24:00 |
| September | 397.10 | 01-SEP-00:10 | 307.95 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.25 | 19-SEP-13:00 | 1.04 | 08-SEP-21:00 |
| October | 397.10 | 01-OCT-00:10 | 307.95 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.57 | 03-OCT-14:00 | 3.32 | 12-OCT-03:00 |
| November | 397.10 | 01-NOV-00:10 | 307.95 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.10 | 13-NOV-14:00 | 6.11 | 28-NOV-05:00 |
| December | 397.10 | 01-DEC-00:10 | 307.95 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 14.06 | 29-DEC-24:00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
| Minimum of Months | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.04 | ||||
| Maximum of Months | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.74 | 27.55 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5796.21 | 07-JAN-19:02 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.83 |
| February | 5794.92 | 27-FEB-13:52 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.35 |
| March | 5774.58 | 19-MAR-19:42 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.36 |
| April | 5753.64 | 09-APR-20:52 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 4232.02 | 13-MAY-07:52 | 1425.00 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.21 |
| June | 4364.45 | 27-JUN-11:52 | 0.00 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.16 |
| July | 2657.33 | 02-JUL-17:02 | 1425.00 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 29.12 | 0.00 |
| August | 2492.98 | 06-AUG-16:40 | 237.50 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 26.07 | 0.00 |
| September | 4806.21 | 29-SEP-06:22 | 1425.00 | 213.79 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.45 |
| October | 5805.69 | 24-OCT-20:52 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 5844.32 | 26-NOV-21:32 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 5875.47 | 08-DEC-17:01 | 0.00 | 438.57 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2492.98 | 0.00 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5875.47 | 1425.00 | 526.29 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 29.12 | 12.35 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4177.57 | 14-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.14 |
| February | 5705.54 | 21-FEB-19:42 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.57 |
| March | 5694.35 | 21-MAR-17:02 | 1239.75 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.95 |
| April | 5688.54 | 09-APR-21:12 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 4242.12 | 13-MAY-07:52 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.18 |
| June | 4300.77 | 27-JUN-11:52 | 296.88 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 |
| July | 2659.04 | 02-JUL-17:17 | 826.50 | 296.04 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 28.22 | 0.00 |
| August | 2427.02 | 07-AUG-17:02 | 1033.12 | 370.05 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 29.45 | 0.00 |
| September | 4707.58 | 29-SEP-06:22 | 1211.25 | 213.79 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.44 |
| October | 5601.76 | 24-OCT-21:42 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 5753.04 | 23-NOV-21:12 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 5744.03 | 04-DEC-20:02 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2427.02 | 296.88 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5753.04 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 29.45 | 20.14 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 3178.02 | 26-JAN-07:01 | 0.00 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 6874.73 | 21-FEB-07:01 | 0.00 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.89 |
| March | 6854.15 | 16-MAR-06:01 | 0.00 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.48 |
| April | 6950.59 | 04-APR-06:01 | 0.00 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.56 |
| May | 6744.15 | 05-MAY-06:01 | 0.00 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 5.05 | 0.00 |
| June | 6496.18 | 05-JUN-06:01 | 0.00 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.53 | 0.00 |
| July | 4998.72 | 05-JUL-06:01 | 0.00 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 9.72 | 0.00 |
| August | 4826.01 | 03-AUG-06:01 | 0.00 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.84 |
| September | 5389.02 | 26-SEP-06:01 | 0.00 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.68 |
| October | 7073.19 | 23-OCT-06:01 | 0.00 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.71 |
| November | 7111.56 | 27-NOV-07:01 | 0.00 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 6874.06 | 01-DEC-07:01 | 0.00 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.02 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3178.02 | 0.00 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 7111.56 | 0.00 | 895.25 | 1949.81 | 0.00 | 0.00 | 0.00 | 0.00 | 9.72 | 22.48 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 3924.00 | 14-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.13 |
| February | 5520.31 | 28-FEB-19:12 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.25 |
| March | 5523.07 | 04-MAR-19:42 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.74 |
| April | 5508.68 | 09-APR-21:12 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 4107.25 | 13-MAY-07:52 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.30 |
| June | 4163.44 | 27-JUN-11:52 | 296.88 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.18 |
| July | 2402.62 | 07-JUL-17:02 | 1239.75 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 4.93 | 0.00 |
| August | 2240.72 | 07-AUG-17:02 | 1033.12 | 370.05 | 2943.11 | 0.00 | 0.00 | 0.00 | 0.00 | 29.45 | 0.00 |
| September | 4555.19 | 29-SEP-06:22 | 1211.25 | 213.79 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.46 |
| October | 5431.62 | 24-OCT-21:42 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 5574.98 | 23-NOV-21:12 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 5565.64 | 01-DEC-20:12 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.96 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2240.72 | 296.88 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5574.98 | 1425.00 | 526.29 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 29.45 | 20.13 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4920.18 | 26-JAN-20:42 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.11 |
| February | 4926.82 | 28-FEB-19:12 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.18 |
| March | 4924.15 | 04-MAR-19:42 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.46 |
| April | 4908.34 | 09-APR-21:12 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 3661.80 | 13-MAY-07:52 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.79 |
| June | 3659.96 | 27-JUN-11:52 | 296.88 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.11 |
| July | 1852.41 | 04-JUL-17:30 | 206.62 | 74.01 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 12.79 | 0.00 |
| August | 1730.33 | 07-AUG-17:12 | 826.50 | 296.04 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 17.16 | 0.00 |
| September | 3989.37 | 29-SEP-06:22 | 1211.25 | 213.79 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.28 |
| October | 4849.38 | 24-OCT-21:42 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 4986.37 | 23-NOV-21:12 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 4978.39 | 01-DEC-20:12 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.51 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1730.33 | 206.62 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4986.37 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 17.16 | 15.11 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4920.37 | 27-JAN-19:02 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.66 |
| February | 4924.09 | 28-FEB-19:12 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.18 |
| March | 4921.88 | 04-MAR-19:42 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.46 |
| April | 4905.71 | 09-APR-21:12 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 3663.05 | 13-MAY-07:52 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.79 |
| June | 3659.82 | 27-JUN-11:52 | 296.88 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.11 |
| July | 1848.91 | 04-JUL-17:30 | 206.62 | 74.01 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 12.79 | 0.00 |
| August | 1727.85 | 07-AUG-17:12 | 826.50 | 296.04 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 17.16 | 0.00 |
| September | 3989.62 | 29-SEP-06:22 | 1211.25 | 213.79 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.28 |
| October | 4850.96 | 24-OCT-21:42 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 4983.82 | 23-NOV-21:12 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 4975.90 | 01-DEC-20:12 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.51 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1727.85 | 206.62 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 4983.82 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 17.16 | 6.66 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5081.16 | 07-JAN-19:02 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.02 |
| February | 5069.82 | 06-FEB-21:32 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 5030.60 | 19-MAR-19:42 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.44 |
| April | 5013.47 | 09-APR-20:52 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 3687.98 | 13-MAY-07:52 | 1425.00 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.81 |
| June | 3750.10 | 27-JUN-11:52 | 0.00 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.10 |
| July | 1841.73 | 04-JUL-17:17 | 950.00 | 296.04 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 12.75 | 0.00 |
| August | 1780.89 | 07-AUG-17:12 | 950.00 | 296.04 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 17.16 | 0.00 |
| September | 4135.87 | 29-SEP-06:22 | 1425.00 | 213.79 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.32 |
| October | 5044.87 | 24-OCT-20:52 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 5110.74 | 26-NOV-21:32 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 5117.27 | 09-DEC-19:12 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.65 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1780.89 | 0.00 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5117.27 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 17.16 | 6.44 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5118.74 | 07-JAN-19:02 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.02 |
| February | 5110.78 | 06-FEB-21:32 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 5075.17 | 19-MAR-19:42 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.44 |
| April | 5064.47 | 09-APR-21:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 3797.30 | 13-MAY-07:52 | 1425.00 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.92 |
| June | 3858.19 | 27-JUN-11:52 | 0.00 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.12 |
| July | 1994.37 | 04-JUL-17:17 | 950.00 | 296.04 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 12.75 | 0.00 |
| August | 1935.41 | 06-AUG-16:40 | 237.50 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 15.73 | 0.00 |
| September | 4219.92 | 29-SEP-06:22 | 1425.00 | 213.79 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.32 |
| October | 5095.50 | 24-OCT-20:52 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 5139.08 | 21-NOV-21:42 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 5157.32 | 09-DEC-19:12 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.65 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1935.41 | 0.00 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5157.32 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 15.73 | 6.44 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 6371.61 | 07-JAN-19:02 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.18 |
| February | 6369.18 | 27-FEB-21:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.20 |
| March | 6330.10 | 19-MAR-19:42 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.80 |
| April | 6297.25 | 09-APR-21:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 4584.27 | 13-MAY-07:52 | 1425.00 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.47 |
| June | 4681.86 | 27-JUN-11:52 | 0.00 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.11 |
| July | 2692.13 | 02-JUL-16:50 | 237.50 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 43.16 | 0.00 |
| August | 2420.46 | 06-AUG-16:30 | 237.50 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 38.34 | 0.00 |
| September | 4976.68 | 29-SEP-06:22 | 1425.00 | 213.79 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.18 |
| October | 6323.64 | 24-OCT-20:52 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 6383.01 | 28-NOV-15:32 | 0.00 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.35 |
| December | 6443.05 | 08-DEC-17:01 | 0.00 | 438.57 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2420.46 | 0.00 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 6443.05 | 1425.00 | 526.29 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 43.16 | 26.20 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5748.94 | 14-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.66 |
| February | 6267.84 | 21-FEB-19:42 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.32 |
| March | 6275.04 | 21-MAR-21:22 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.97 |
| April | 6234.70 | 09-APR-21:12 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 4593.17 | 13-MAY-07:52 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.42 |
| June | 4619.48 | 27-JUN-11:52 | 296.88 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.13 |
| July | 2662.56 | 02-JUL-17:17 | 826.50 | 296.04 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 40.50 | 0.00 |
| August | 2307.97 | 07-AUG-16:20 | 370.50 | 164.46 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 47.07 | 0.00 |
| September | 4852.03 | 29-SEP-06:22 | 1211.25 | 213.79 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.07 |
| October | 6131.33 | 24-OCT-21:42 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 6277.70 | 23-NOV-21:12 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 6265.84 | 01-DEC-20:12 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.67 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2307.97 | 296.88 | 54.82 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 6277.70 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 47.07 | 29.66 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 6154.32 | 07-JAN-19:02 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.14 |
| February | 6152.87 | 27-FEB-13:52 | 0.00 | 65.78 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.84 |
| March | 6127.22 | 02-MAR-12:32 | 0.00 | 65.78 | 2436.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.14 |
| April | 6085.33 | 09-APR-21:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 4439.31 | 13-MAY-07:52 | 1425.00 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.65 |
| June | 4522.64 | 27-JUN-11:52 | 0.00 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.13 |
| July | 2295.99 | 02-JUL-16:30 | 237.50 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 43.25 | 0.00 |
| August | 2169.16 | 07-AUG-16:01 | 0.00 | 383.74 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 47.92 | 0.00 |
| September | 4796.24 | 29-SEP-06:22 | 1425.00 | 213.79 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.19 |
| October | 6108.20 | 24-OCT-20:52 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 6167.25 | 26-NOV-21:32 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 6217.84 | 08-DEC-17:01 | 0.00 | 438.57 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2169.16 | 0.00 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 6217.84 | 1425.00 | 526.29 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 47.92 | 17.84 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5543.23 | 14-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.57 |
| February | 6048.88 | 28-FEB-19:12 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.68 |
| March | 6056.23 | 19-MAR-20:12 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.86 |
| April | 6022.96 | 09-APR-21:12 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 4441.35 | 13-MAY-07:52 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.60 |
| June | 4459.59 | 27-JUN-11:52 | 296.88 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.14 |
| July | 2304.96 | 07-JUL-16:17 | 370.50 | 164.46 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 20.08 | 0.00 |
| August | 2084.18 | 07-AUG-16:20 | 370.50 | 164.46 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 47.07 | 0.00 |
| September | 4671.48 | 29-SEP-06:22 | 1211.25 | 213.79 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.09 |
| October | 5884.83 | 24-OCT-21:42 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 6056.19 | 01-NOV-20:22 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 |
| December | 6051.01 | 01-DEC-20:12 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.57 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2084.18 | 296.88 | 54.82 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 6056.23 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 47.07 | 29.57 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5335.14 | 27-JAN-19:02 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.71 |
| February | 5338.74 | 06-FEB-21:32 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 5353.22 | 21-MAR-21:22 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.46 |
| April | 5301.73 | 09-APR-21:12 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 3884.74 | 13-MAY-07:52 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.90 |
| June | 3862.68 | 27-JUN-11:52 | 296.88 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.09 |
| July | 1725.79 | 02-JUL-17:35 | 413.25 | 148.02 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 22.89 | 0.00 |
| August | 1563.48 | 07-AUG-17:12 | 826.50 | 296.04 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 24.62 | 0.00 |
| September | 4085.60 | 29-SEP-06:22 | 1211.25 | 213.79 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.10 |
| October | 5158.68 | 24-OCT-21:42 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 5350.33 | 23-NOV-21:12 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 5368.01 | 01-DEC-20:12 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.68 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1563.48 | 296.88 | 54.82 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5368.01 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 24.62 | 9.71 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5332.12 | 27-JAN-19:02 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.72 |
| February | 5335.52 | 06-FEB-21:32 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 5348.85 | 21-MAR-21:22 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.46 |
| April | 5298.01 | 09-APR-21:12 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 3881.86 | 13-MAY-07:52 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.90 |
| June | 3859.61 | 27-JUN-11:52 | 296.88 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.09 |
| July | 1720.60 | 02-JUL-17:35 | 413.25 | 148.02 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 22.89 | 0.00 |
| August | 1560.66 | 07-AUG-17:12 | 826.50 | 296.04 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 24.62 | 0.00 |
| September | 4082.09 | 29-SEP-06:22 | 1211.25 | 213.79 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.10 |
| October | 5154.82 | 24-OCT-21:42 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 5347.01 | 23-NOV-21:12 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 5364.50 | 01-DEC-20:12 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.68 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1560.66 | 296.88 | 54.82 | 1177.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5364.50 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 24.62 | 9.72 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5487.28 | 07-JAN-19:02 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.40 |
| February | 5468.86 | 27-FEB-21:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.14 |
| March | 5428.56 | 02-MAR-20:32 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.93 |
| April | 5397.60 | 09-APR-20:52 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 3904.96 | 13-MAY-07:52 | 1425.00 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.92 |
| June | 3940.51 | 27-JUN-11:52 | 0.00 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.08 |
| July | 1721.10 | 02-JUL-17:02 | 1425.00 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 25.21 | 0.00 |
| August | 1643.15 | 06-AUG-16:20 | 712.50 | 164.46 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 23.69 | 0.00 |
| September | 4233.84 | 29-SEP-06:22 | 1425.00 | 213.79 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.18 |
| October | 5417.41 | 24-OCT-20:52 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 5495.46 | 26-NOV-21:32 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 5507.26 | 08-DEC-17:01 | 0.00 | 438.57 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1643.15 | 0.00 | 54.82 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5507.26 | 1425.00 | 526.29 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 25.21 | 16.14 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5484.70 | 07-JAN-19:02 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.40 |
| February | 5464.75 | 27-FEB-21:02 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.13 |
| March | 5425.14 | 02-MAR-20:32 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.93 |
| April | 5393.99 | 09-APR-20:52 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 3902.12 | 13-MAY-07:52 | 1425.00 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.93 |
| June | 3937.44 | 27-JUN-11:52 | 0.00 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.08 |
| July | 1716.89 | 02-JUL-16:40 | 237.50 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 26.06 | 0.00 |
| August | 1640.80 | 06-AUG-16:20 | 712.50 | 164.46 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 23.69 | 0.00 |
| September | 4230.35 | 29-SEP-06:22 | 1425.00 | 213.79 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.18 |
| October | 5413.69 | 24-OCT-20:52 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 5492.03 | 26-NOV-21:32 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 5503.54 | 08-DEC-17:01 | 0.00 | 438.57 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 1640.80 | 0.00 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5503.54 | 1425.00 | 526.29 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 26.06 | 16.13 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 6901.39 | 19-JAN-17:12 | 0.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.70 |
| February | 7094.24 | 15-FEB-14:22 | 0.00 | 54.82 | 1913.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.22 |
| March | 6890.04 | 19-MAR-19:42 | 1425.00 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.17 |
| April | 6839.00 | 09-APR-20:52 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 4926.08 | 13-MAY-07:52 | 1425.00 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.46 |
| June | 4967.92 | 27-JUN-11:52 | 0.00 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.16 |
| July | 3593.75 | 02-JUL-16:30 | 237.50 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 57.07 | 0.00 |
| August | 3201.32 | 06-AUG-16:20 | 712.50 | 164.46 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 51.78 | 0.00 |
| September | 5066.25 | 29-SEP-06:22 | 1425.00 | 213.79 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.21 | 0.00 |
| October | 6870.17 | 24-OCT-20:52 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 6984.96 | 28-NOV-15:32 | 0.00 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.17 |
| December | 7010.98 | 08-DEC-17:01 | 0.00 | 438.57 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3201.32 | 0.00 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 7094.24 | 1425.00 | 526.29 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 57.07 | 19.17 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 3135.99 | 14-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38.52 |
| February | 6849.19 | 21-FEB-19:42 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.95 |
| March | 6866.38 | 22-MAR-20:12 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.11 |
| April | 6806.75 | 09-APR-21:12 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 4966.02 | 13-MAY-07:52 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.41 |
| June | 4941.55 | 27-JUN-11:52 | 296.88 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.19 |
| July | 3535.68 | 02-JUL-16:50 | 123.50 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 56.95 | 0.00 |
| August | 3053.87 | 07-AUG-16:20 | 370.50 | 164.46 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 62.07 | 0.00 |
| September | 4999.88 | 29-SEP-06:22 | 1211.25 | 213.79 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.30 | 0.00 |
| October | 6705.98 | 24-OCT-21:42 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 6858.39 | 01-NOV-20:22 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.45 |
| December | 6807.16 | 01-DEC-20:12 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.08 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 3053.87 | 123.50 | 54.82 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 6866.38 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 62.07 | 38.52 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 6585.10 | 19-JAN-15:32 | 0.00 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.39 |
| February | 6844.79 | 15-FEB-14:22 | 0.00 | 54.82 | 1913.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.83 |
| March | 6680.41 | 16-MAR-13:12 | 0.00 | 65.78 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.43 |
| April | 6537.41 | 09-APR-20:52 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 4716.33 | 13-MAY-07:52 | 1425.00 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.62 |
| June | 4756.99 | 27-JUN-11:52 | 0.00 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.19 |
| July | 3048.62 | 07-JUL-15:10 | 0.00 | 38.37 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 55.92 | 0.00 |
| August | 2866.67 | 07-AUG-15:10 | 0.00 | 38.37 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 66.99 | 0.00 |
| September | 4827.96 | 29-SEP-06:22 | 1425.00 | 213.79 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 0.00 |
| October | 6567.87 | 24-OCT-20:52 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 6654.04 | 28-NOV-15:32 | 0.00 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.15 |
| December | 6684.92 | 08-DEC-17:01 | 0.00 | 438.57 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2866.67 | 0.00 | 38.37 | 470.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 6844.79 | 1425.00 | 438.57 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 66.99 | 20.43 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 2202.25 | 26-JAN-20:42 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.42 |
| February | 6554.02 | 16-FEB-14:21 | 415.63 | 76.74 | 2678.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.86 |
| March | 6567.33 | 21-MAR-19:42 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.33 |
| April | 6513.73 | 09-APR-21:12 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 4756.21 | 13-MAY-07:52 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.58 |
| June | 4729.90 | 27-JUN-11:52 | 296.88 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.22 |
| July | 3034.16 | 07-JUL-16:01 | 988.00 | 438.57 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 30.68 | 0.00 |
| August | 2733.00 | 07-AUG-16:01 | 864.50 | 383.74 | 4120.36 | 0.00 | 0.00 | 0.00 | 0.00 | 63.20 | 0.00 |
| September | 4760.84 | 29-SEP-06:22 | 1211.25 | 213.79 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.26 | 0.00 |
| October | 6419.73 | 24-OCT-21:42 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 6555.91 | 29-NOV-18:02 | 1239.75 | 444.06 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 6474.62 | 01-DEC-15:41 | 415.63 | 134.32 | 2801.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.79 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2202.25 | 296.88 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 6567.33 | 1425.00 | 526.29 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 63.20 | 47.42 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4650.06 | 14-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.34 |
| February | 5937.06 | 21-FEB-19:42 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.29 |
| March | 5950.78 | 21-MAR-19:42 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.48 |
| April | 5910.35 | 09-APR-21:12 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 4327.25 | 13-MAY-07:52 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.70 |
| June | 4248.96 | 27-JUN-11:52 | 296.88 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.15 |
| July | 2382.88 | 02-JUL-17:17 | 826.50 | 296.04 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 32.23 | 0.00 |
| August | 2149.88 | 07-AUG-16:20 | 370.50 | 164.46 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 37.44 | 0.00 |
| September | 4345.71 | 29-SEP-06:22 | 1211.25 | 213.79 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.02 | 0.00 |
| October | 5800.06 | 24-OCT-21:42 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 5947.64 | 01-NOV-20:22 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.27 |
| December | 5834.79 | 01-DEC-15:41 | 415.63 | 134.32 | 2801.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.61 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2149.88 | 296.88 | 54.82 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5950.78 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 37.44 | 23.34 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 4519.33 | 14-JAN-22:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.33 |
| February | 5926.20 | 21-FEB-19:42 | 1239.75 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.28 |
| March | 5941.67 | 21-MAR-19:42 | 1239.75 | 526.29 | 3143.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.49 |
| April | 5900.38 | 09-APR-21:12 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 4319.18 | 13-MAY-07:52 | 555.75 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.70 |
| June | 4241.46 | 27-JUN-11:52 | 296.88 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.15 |
| July | 2369.92 | 02-JUL-17:17 | 826.50 | 296.04 | 2354.49 | 0.00 | 0.00 | 0.00 | 0.00 | 32.23 | 0.00 |
| August | 2144.21 | 07-AUG-16:20 | 370.50 | 164.46 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 37.44 | 0.00 |
| September | 4336.61 | 29-SEP-06:22 | 1211.25 | 213.79 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.02 | 0.00 |
| October | 5789.65 | 24-OCT-21:42 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 5937.13 | 01-NOV-20:22 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.27 |
| December | 5829.47 | 01-DEC-15:41 | 415.63 | 134.32 | 2801.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.68 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2144.21 | 296.88 | 54.82 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 5941.67 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 37.44 | 23.33 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 6001.81 | 07-JAN-19:02 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.69 |
| February | 6141.34 | 15-FEB-14:22 | 0.00 | 54.82 | 1913.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.60 |
| March | 6031.86 | 16-MAR-13:12 | 0.00 | 65.78 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.00 |
| April | 5941.90 | 09-APR-21:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 4300.00 | 13-MAY-07:52 | 1425.00 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.72 |
| June | 4279.25 | 27-JUN-11:52 | 0.00 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.13 |
| July | 2431.06 | 02-JUL-16:17 | 712.50 | 164.46 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 34.46 | 0.00 |
| August | 2274.57 | 06-AUG-16:02 | 1425.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 31.98 | 0.00 |
| September | 4420.92 | 29-SEP-06:22 | 1425.00 | 213.79 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.04 |
| October | 5959.52 | 24-OCT-20:52 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 6039.47 | 28-NOV-15:32 | 0.00 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.50 |
| December | 6069.52 | 08-DEC-17:01 | 0.00 | 438.57 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2274.57 | 0.00 | 54.82 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 6141.34 | 1425.00 | 526.29 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 34.46 | 10.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 5991.61 | 07-JAN-19:02 | 1425.00 | 526.29 | 3284.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.69 |
| February | 6138.97 | 15-FEB-14:22 | 0.00 | 54.82 | 1913.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.65 |
| March | 6023.18 | 16-MAR-13:12 | 0.00 | 65.78 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.22 |
| April | 5931.47 | 09-APR-21:52 | 1425.00 | 197.37 | 2507.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 4292.04 | 13-MAY-07:52 | 1425.00 | 98.68 | 2330.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.72 |
| June | 4271.78 | 27-JUN-11:52 | 0.00 | 54.82 | 2030.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.13 |
| July | 2421.52 | 02-JUL-16:20 | 712.50 | 164.46 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 34.46 | 0.00 |
| August | 2268.19 | 06-AUG-16:02 | 1425.00 | 328.92 | 3531.74 | 0.00 | 0.00 | 0.00 | 0.00 | 31.98 | 0.00 |
| September | 4411.90 | 29-SEP-06:22 | 1425.00 | 213.79 | 2295.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.04 |
| October | 5948.54 | 24-OCT-20:52 | 1425.00 | 361.83 | 3001.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 6028.49 | 28-NOV-15:32 | 0.00 | 115.13 | 2401.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.50 |
| December | 6058.87 | 08-DEC-17:01 | 0.00 | 438.57 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 2268.19 | 0.00 | 54.82 | 1765.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 6138.97 | 1425.00 | 526.29 | 4708.98 | 0.00 | 0.00 | 0.00 | 0.00 | 34.46 | 10.22 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.48 | 0.00 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.67 | 0.00 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.99 | 0.00 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.42 | 0.00 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.68 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.67 | 1.68 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.15 | 0.00 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 1.89 | 0.00 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.43 | 0.00 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.10 | 0.00 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.02 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
| Minimum of Months | 0.00 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 397.10 | 307.95 | 80.16 | 0.00 | 0.00 | 0.00 | 0.00 | 1.89 | 1.02 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
| January | 0.00 | 01-JAN-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 01-FEB-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 01-MAR-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 01-APR-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 01-MAY-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.37 | 0.00 |
| June | 0.00 | 01-JUN-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 01-JUL-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.82 | 0.00 |
| August | 0.00 | 01-AUG-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | 0.00 |
| September | 0.00 | 01-SEP-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.21 | 0.00 |
| October | 0.00 | 01-OCT-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 01-NOV-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 01-DEC-00:10 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.38 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
| Minimum of Months | 0.00 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 397.10 | 307.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.82 | 1.38 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
| January | 0.570732E+11 | 40871.28 | 12-JAN-17:00 | 0.337162E+11 | 23788.17 | 21-JAN-07:00 |
| February | 0.559829E+11 | 48294.78 | 08-FEB-18:30 | 0.297961E+11 | 23710.17 | 01-FEB-07:00 |
| March | 0.759362E+11 | 53753.56 | 28-MAR-16:30 | 0.308831E+11 | 23169.18 | 01-MAR-07:49 |
| April | 0.927156E+11 | 60132.93 | 16-APR-16:10 | 0.269515E+11 | 21016.41 | 01-APR-06:40 |
| May | 0.110732E+12 | 64441.99 | 03-MAY-16:30 | 0.247516E+11 | 18924.49 | 01-MAY-06:00 |
| June | 0.112142E+12 | 66687.50 | 10-JUN-16:49 | 0.216920E+11 | 16875.14 | 02-JUN-06:49 |
| July | 0.115690E+12 | 65722.44 | 02-JUL-16:49 | 0.214674E+11 | 15672.56 | 01-JUL-06:40 |
| August | 0.111261E+12 | 61970.68 | 07-AUG-16:30 | 0.221663E+11 | 16122.47 | 30-AUG-06:19 |
| September | 0.100973E+12 | 59313.32 | 24-SEP-16:10 | 0.235200E+11 | 18547.72 | 30-SEP-06:40 |
| October | 0.884477E+11 | 56911.98 | 02-OCT-16:10 | 0.273228E+11 | 20782.89 | 28-OCT-06:49 |
| November | 0.691888E+11 | 48615.29 | 04-NOV-16:10 | 0.294431E+11 | 23012.44 | 30-NOV-07:30 |
| December | 0.593286E+11 | 42725.91 | 01-DEC-20:19 | 0.327705E+11 | 23686.88 | 31-DEC-07:00 |
| Annual Sum or Average | 0.104947E+13 | 0.324481E+12 | ||||
| Minimum of Months | 0.559829E+11 | 40871.28 | 0.214674E+11 | 15672.56 | ||
| Maximum of Months | 0.115690E+12 | 66687.50 | 0.337162E+11 | 23788.17 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [J] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [J] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
| January | 0.618562E+10 | 0.317424E+10 | 0.385428E+11 | 0.00 | 0.589639E+10 | 38818862.27 | 0.438062E+09 | 0.279722E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.559770E+10 | 0.274689E+10 | 0.348258E+11 | 0.00 | 0.628715E+10 | 35062198.18 | 50786583.53 | 0.643946E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.621989E+10 | 0.284648E+10 | 0.385844E+11 | 0.00 | 0.986273E+10 | 38818862.27 | 0.00 | 0.183839E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.599345E+10 | 0.256410E+10 | 0.373085E+11 | 0.00 | 0.133529E+11 | 37566640.91 | 0.00 | 0.334591E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.620847E+10 | 0.248216E+10 | 0.385705E+11 | 0.00 | 0.165085E+11 | 38818862.27 | 0.00 | 0.469232E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.601630E+10 | 0.231197E+10 | 0.373361E+11 | 0.00 | 0.168200E+11 | 37566640.91 | 0.00 | 0.496195E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.618562E+10 | 0.243804E+10 | 0.385428E+11 | 0.00 | 0.174157E+11 | 38818862.27 | 0.00 | 0.510689E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.621989E+10 | 0.257292E+10 | 0.385844E+11 | 0.00 | 0.166270E+11 | 38818862.27 | 0.00 | 0.472183E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.599345E+10 | 0.267251E+10 | 0.373085E+11 | 0.00 | 0.148937E+11 | 37566640.91 | 0.00 | 0.400671E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.619704E+10 | 0.295993E+10 | 0.385567E+11 | 0.00 | 0.123200E+11 | 38818862.27 | 0.00 | 0.283753E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.599345E+10 | 0.302927E+10 | 0.373085E+11 | 0.00 | 0.861637E+10 | 37566640.91 | 0.00 | 0.142037E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.618562E+10 | 0.323349E+10 | 0.385428E+11 | 0.00 | 0.635989E+10 | 38818862.27 | 0.176840E+09 | 0.479116E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.729965E+11 | 0.330320E+11 | 0.454012E+12 | 0.00 | 0.144960E+12 | 0.457061E+09 | 0.665688E+09 | 0.343347E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.559770E+10 | 0.231197E+10 | 0.348258E+11 | 0.00 | 0.589639E+10 | 35062198.18 | 0.00 | 0.279722E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.621989E+10 | 0.323349E+10 | 0.385844E+11 | 0.00 | 0.174157E+11 | 38818862.27 | 0.438062E+09 | 0.510689E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [J] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.337162E+11 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.297961E+11 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.308831E+11 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.269515E+11 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.247516E+11 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.216920E+11 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.214674E+11 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.221663E+11 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.235200E+11 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.273228E+11 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.294431E+11 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.327705E+11 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.324481E+12 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.214674E+11 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.337162E+11 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY {Maximum} [W] | PUMPS:ELECTRICITY {TIMESTAMP} | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
| January | 4040.47 | 01-JAN-19:10 | 2101.03 | 01-JAN-00:10 | 22246.15 | 03-JAN-17:10 | 0.00 | 4941.83 | 12-JAN-15:39 | 14.49 | 01-JAN-07:10 | 1649.55 | 02-JAN-05:00 |
| February | 4040.47 | 01-FEB-19:10 | 2101.03 | 01-FEB-00:10 | 22246.15 | 01-FEB-17:10 | 0.00 | 7157.40 | 19-FEB-13:50 | 14.49 | 01-FEB-07:10 | 858.84 | 11-FEB-05:00 |
| March | 4040.47 | 01-MAR-19:10 | 2101.03 | 01-MAR-00:10 | 22246.15 | 01-MAR-17:10 | 0.00 | 7500.19 | 15-MAR-12:00 | 14.49 | 01-MAR-06:10 | 0.00 | 01-MAR-00:10 |
| April | 4040.47 | 01-APR-18:10 | 2101.03 | 01-APR-00:10 | 22246.15 | 03-APR-16:10 | 0.00 | 8290.82 | 27-APR-16:10 | 14.49 | 01-APR-06:10 | 0.00 | 01-APR-00:10 |
| May | 4040.47 | 01-MAY-18:10 | 2101.03 | 01-MAY-00:10 | 22246.15 | 01-MAY-16:10 | 0.00 | 9214.13 | 03-MAY-16:10 | 14.49 | 01-MAY-06:10 | 0.00 | 01-MAY-00:10 |
| June | 4040.47 | 01-JUN-18:10 | 2101.03 | 01-JUN-00:10 | 22246.15 | 01-JUN-16:10 | 0.00 | 9389.71 | 07-JUN-16:19 | 14.49 | 01-JUN-06:10 | 0.00 | 01-JUN-00:10 |
| July | 4040.47 | 01-JUL-18:10 | 2101.03 | 01-JUL-00:10 | 22246.15 | 03-JUL-16:10 | 0.00 | 9186.60 | 02-JUL-17:10 | 14.49 | 01-JUL-16:19 | 0.00 | 01-JUL-00:10 |
| August | 4040.47 | 01-AUG-18:10 | 2101.03 | 01-AUG-00:10 | 22246.15 | 01-AUG-16:10 | 0.00 | 8526.79 | 07-AUG-16:10 | 14.49 | 01-AUG-16:19 | 0.00 | 01-AUG-00:10 |
| September | 4040.47 | 01-SEP-18:10 | 2101.03 | 01-SEP-00:10 | 22246.15 | 01-SEP-16:10 | 0.00 | 8156.90 | 24-SEP-16:10 | 14.49 | 01-SEP-06:40 | 0.00 | 01-SEP-00:10 |
| October | 4040.47 | 01-OCT-18:10 | 2101.03 | 01-OCT-00:10 | 22246.15 | 02-OCT-16:10 | 0.00 | 7779.21 | 02-OCT-15:09 | 14.49 | 01-OCT-05:19 | 0.00 | 01-OCT-00:10 |
| November | 4040.47 | 01-NOV-18:10 | 2101.03 | 01-NOV-00:10 | 22246.15 | 01-NOV-16:10 | 0.00 | 7512.14 | 11-NOV-11:20 | 14.49 | 01-NOV-05:10 | 0.00 | 01-NOV-00:10 |
| December | 4040.47 | 01-DEC-19:10 | 2101.03 | 01-DEC-00:10 | 22246.15 | 01-DEC-17:10 | 0.00 | 6566.38 | 02-DEC-14:39 | 14.49 | 01-DEC-06:19 | 1431.07 | 23-DEC-05:00 |
| Annual Sum or Average | 0.00 | ||||||||||||
| Minimum of Months | 4040.47 | 2101.03 | 22246.15 | 0.00 | 4941.83 | 14.49 | 0.00 | ||||||
| Maximum of Months | 4040.47 | 2101.03 | 22246.15 | 0.00 | 9389.71 | 14.49 | 1649.55 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY {Maximum} [W] | HEATRECOVERY:ELECTRICITY {TIMESTAMP} | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
| January | 11456.26 | 12-JAN-15:39 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
| February | 19079.24 | 19-FEB-13:50 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
| March | 21604.53 | 28-MAR-15:39 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
| April | 26634.05 | 16-APR-16:10 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
| May | 30478.28 | 01-MAY-15:39 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 |
| June | 32110.08 | 10-JUN-16:49 | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 |
| July | 31325.00 | 02-JUL-17:10 | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 |
| August | 28656.39 | 07-AUG-15:30 | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 |
| September | 26382.44 | 22-SEP-15:09 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 |
| October | 25221.38 | 02-OCT-15:09 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
| November | 22025.98 | 09-NOV-10:39 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
| December | 16699.92 | 02-DEC-14:39 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 11456.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Maximum of Months | 32110.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
| January | 40871.28 | 12-JAN-17:00 | 3020.75 | 22246.15 | 2101.03 | 0.00 | 4426.24 | 14.49 | 0.00 | 9062.62 | 0.00 |
| February | 48294.78 | 08-FEB-18:30 | 3615.61 | 20849.51 | 2101.03 | 0.00 | 6195.82 | 14.49 | 0.00 | 15518.32 | 0.00 |
| March | 53753.56 | 28-MAR-16:30 | 3020.75 | 22246.15 | 0.00 | 0.00 | 7203.16 | 14.49 | 0.00 | 21269.01 | 0.00 |
| April | 60132.93 | 16-APR-16:10 | 3020.75 | 22179.86 | 0.00 | 0.00 | 8283.78 | 14.49 | 0.00 | 26634.05 | 0.00 |
| May | 64441.99 | 03-MAY-16:30 | 3020.75 | 22246.15 | 0.00 | 0.00 | 9166.93 | 14.49 | 0.00 | 29993.67 | 0.00 |
| June | 66687.50 | 10-JUN-16:49 | 3020.75 | 22179.86 | 0.00 | 0.00 | 9362.33 | 14.49 | 0.00 | 32110.08 | 0.00 |
| July | 65722.44 | 02-JUL-16:49 | 3020.75 | 22179.86 | 0.00 | 0.00 | 9182.76 | 14.49 | 0.00 | 31324.59 | 0.00 |
| August | 61970.68 | 07-AUG-16:30 | 3020.75 | 22246.15 | 0.00 | 0.00 | 8505.92 | 14.49 | 0.00 | 28183.37 | 0.00 |
| September | 59313.32 | 24-SEP-16:10 | 3020.75 | 22179.86 | 0.00 | 0.00 | 8156.90 | 14.49 | 0.00 | 25941.32 | 0.00 |
| October | 56911.98 | 02-OCT-16:10 | 3020.75 | 22246.15 | 0.00 | 0.00 | 7749.08 | 14.49 | 0.00 | 23881.52 | 0.00 |
| November | 48615.29 | 04-NOV-16:10 | 3020.75 | 22179.86 | 0.00 | 0.00 | 6370.75 | 14.49 | 0.00 | 17029.44 | 0.00 |
| December | 42725.91 | 01-DEC-20:19 | 4040.47 | 17993.99 | 2101.03 | 0.00 | 5527.02 | 14.49 | 0.00 | 13048.91 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | |||||||||
| Minimum of Months | 40871.28 | 3020.75 | 17993.99 | 0.00 | 0.00 | 4426.24 | 14.49 | 0.00 | 9062.62 | 0.00 | |
| Maximum of Months | 66687.50 | 4040.47 | 22246.15 | 2101.03 | 0.00 | 9362.33 | 14.49 | 0.00 | 32110.08 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS {Maximum} [W] | WATERSYSTEMS:NATURALGAS {TIMESTAMP} | COGENERATION:NATURALGAS [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 23788.17 | 21-JAN-07:00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 23710.17 | 01-FEB-07:00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 23169.18 | 01-MAR-07:49 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 21016.41 | 01-APR-06:40 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 18924.49 | 01-MAY-06:00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 16875.14 | 02-JUN-06:49 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 15672.56 | 01-JUL-06:40 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 16122.47 | 30-AUG-06:19 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 18547.72 | 30-SEP-06:40 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 20782.89 | 28-OCT-06:49 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 23012.44 | 30-NOV-07:30 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 23686.88 | 31-DEC-07:00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 15672.56 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 23788.17 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.63 | 0.00 | 24.63 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 2.17 | 24.93 | 0.00 | 24.93 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 4.17 | 25.39 | 0.00 | 25.39 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 25.56 | 0.00 | 25.56 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 7.67 | 25.63 | 0.00 | 25.63 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 8.17 | 25.76 | 0.00 | 25.76 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 5.67 | 25.63 | 0.00 | 25.63 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 2.83 | 24.97 | 0.00 | 24.97 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 36.83 | 25.53 | 0.00 | 25.53 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 8.17 | 25.76 | 0.00 | 25.76 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 239.67 | 23.53 | 82.50 | 23.93 | 0.00 | 23.93 |
| February | 73.83 | 23.65 | 190.00 | 24.58 | 0.00 | 24.58 |
| March | 0.33 | 23.67 | 311.17 | 24.46 | 0.00 | 24.46 |
| April | 0.67 | 25.54 | 422.00 | 24.12 | 0.67 | 24.12 |
| May | 11.33 | 24.30 | 515.00 | 24.01 | 11.33 | 24.02 |
| June | 45.83 | 24.05 | 492.00 | 24.01 | 45.83 | 24.01 |
| July | 51.83 | 24.00 | 533.00 | 24.00 | 51.83 | 24.00 |
| August | 45.50 | 24.00 | 506.00 | 24.00 | 45.50 | 24.00 |
| September | 37.83 | 24.00 | 510.00 | 24.01 | 37.83 | 24.01 |
| October | 6.00 | 25.90 | 524.00 | 24.36 | 6.00 | 24.37 |
| November | 0.00 | 0.00 | 421.67 | 24.63 | 0.00 | 24.63 |
| December | 72.50 | 23.87 | 158.83 | 24.68 | 0.00 | 24.68 |
| Annual Sum or Average | 585.33 | 23.78 | 4666.17 | 24.18 | 199.00 | 24.18 |
| Minimum of Months | 0.00 | 0.00 | 82.50 | 23.93 | 0.00 | 23.93 |
| Maximum of Months | 239.67 | 25.90 | 533.00 | 24.68 | 51.83 | 24.68 |
Report: ComfortReportSimple55Monthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 638.83 | 22.96 | 9.33 | 22.99 | 0.00 | 22.99 |
| February | 313.83 | 23.43 | 130.83 | 23.87 | 0.00 | 23.87 |
| March | 26.67 | 23.84 | 392.83 | 24.44 | 0.00 | 24.44 |
| April | 1.50 | 25.34 | 558.17 | 24.12 | 1.50 | 24.12 |
| May | 11.00 | 24.31 | 744.00 | 24.01 | 11.00 | 24.01 |
| June | 47.17 | 24.06 | 720.00 | 24.01 | 47.17 | 24.01 |
| July | 56.00 | 24.00 | 744.00 | 24.00 | 56.00 | 24.00 |
| August | 45.00 | 24.00 | 744.00 | 24.00 | 45.00 | 24.00 |
| September | 35.67 | 24.00 | 720.00 | 24.01 | 35.67 | 24.01 |
| October | 18.33 | 25.70 | 743.83 | 24.37 | 18.33 | 24.40 |
| November | 0.00 | 0.00 | 483.67 | 24.79 | 0.00 | 24.79 |
| December | 306.50 | 23.67 | 149.33 | 24.18 | 0.00 | 24.18 |
| Annual Sum or Average | 1500.50 | 23.40 | 6140.00 | 24.04 | 214.67 | 24.04 |
| Minimum of Months | 0.00 | 0.00 | 9.33 | 22.99 | 0.00 | 22.99 |
| Maximum of Months | 638.83 | 25.70 | 744.00 | 24.79 | 56.00 | 24.79 |
Report: ComfortReportSimple55Monthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 35.33 | 23.69 | 18.67 | 23.79 | 0.00 | 23.79 |
| February | 6.33 | 23.88 | 81.83 | 23.99 | 0.00 | 23.99 |
| March | 0.00 | 0.00 | 149.00 | 24.00 | 0.00 | 24.00 |
| April | 0.00 | 0.00 | 140.00 | 24.00 | 0.00 | 24.00 |
| May | 0.83 | 24.00 | 154.00 | 24.00 | 0.83 | 24.00 |
| June | 2.17 | 24.00 | 154.00 | 24.00 | 2.17 | 24.00 |
| July | 3.17 | 24.00 | 140.00 | 24.00 | 3.17 | 24.00 |
| August | 3.67 | 24.00 | 161.00 | 24.00 | 3.67 | 24.00 |
| September | 2.00 | 24.00 | 140.00 | 24.00 | 2.00 | 24.00 |
| October | 0.00 | 0.00 | 147.00 | 24.00 | 0.00 | 24.00 |
| November | 0.00 | 0.00 | 140.00 | 24.00 | 0.00 | 24.00 |
| December | 4.33 | 23.96 | 81.83 | 24.00 | 0.00 | 24.00 |
| Annual Sum or Average | 57.83 | 23.79 | 1507.33 | 23.99 | 11.83 | 23.99 |
| Minimum of Months | 0.00 | 0.00 | 18.67 | 23.79 | 0.00 | 23.79 |
| Maximum of Months | 35.33 | 24.00 | 161.00 | 24.00 | 3.67 | 24.00 |
Report: ComfortReportSimple55Monthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 639.50 | 23.01 | 7.83 | 23.04 | 0.00 | 23.04 |
| February | 290.83 | 23.50 | 148.67 | 23.98 | 0.00 | 23.98 |
| March | 15.17 | 23.85 | 404.83 | 24.54 | 0.00 | 24.54 |
| April | 1.50 | 25.46 | 565.00 | 24.13 | 1.50 | 24.13 |
| May | 11.00 | 24.31 | 744.00 | 24.01 | 11.00 | 24.01 |
| June | 49.00 | 24.05 | 720.00 | 24.01 | 49.00 | 24.01 |
| July | 56.67 | 24.00 | 744.00 | 24.00 | 56.67 | 24.00 |
| August | 44.50 | 24.00 | 744.00 | 24.00 | 44.50 | 24.00 |
| September | 35.33 | 24.00 | 720.00 | 24.01 | 35.33 | 24.01 |
| October | 17.33 | 25.74 | 743.67 | 24.39 | 17.33 | 24.42 |
| November | 0.00 | 0.00 | 494.83 | 24.82 | 0.00 | 24.82 |
| December | 285.67 | 23.70 | 150.83 | 24.20 | 0.00 | 24.20 |
| Annual Sum or Average | 1446.50 | 23.43 | 6187.67 | 24.06 | 215.33 | 24.07 |
| Minimum of Months | 0.00 | 0.00 | 7.83 | 23.04 | 0.00 | 23.04 |
| Maximum of Months | 639.50 | 25.74 | 744.00 | 24.82 | 56.67 | 24.82 |
Report: ComfortReportSimple55Monthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 536.67 | 23.33 | 19.17 | 23.38 | 0.00 | 23.38 |
| February | 171.50 | 23.73 | 160.83 | 24.29 | 0.00 | 24.29 |
| March | 0.33 | 23.63 | 383.17 | 24.57 | 0.00 | 24.57 |
| April | 1.50 | 25.42 | 478.00 | 24.15 | 1.50 | 24.16 |
| May | 13.00 | 24.26 | 744.00 | 24.01 | 13.00 | 24.01 |
| June | 69.17 | 24.04 | 720.00 | 24.01 | 69.17 | 24.01 |
| July | 153.17 | 24.00 | 744.00 | 24.00 | 153.17 | 24.00 |
| August | 186.17 | 24.00 | 744.00 | 24.00 | 186.17 | 24.00 |
| September | 105.50 | 24.00 | 720.00 | 24.01 | 105.50 | 24.01 |
| October | 20.67 | 25.66 | 744.00 | 24.37 | 20.67 | 24.40 |
| November | 0.00 | 0.00 | 476.83 | 24.79 | 0.00 | 24.79 |
| December | 167.00 | 23.89 | 161.83 | 24.50 | 0.00 | 24.50 |
| Annual Sum or Average | 1424.67 | 23.73 | 6095.83 | 24.12 | 549.17 | 24.12 |
| Minimum of Months | 0.00 | 0.00 | 19.17 | 23.38 | 0.00 | 23.38 |
| Maximum of Months | 536.67 | 25.66 | 744.00 | 24.79 | 186.17 | 24.79 |
Report: ComfortReportSimple55Monthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 534.83 | 23.34 | 19.00 | 23.38 | 0.00 | 23.38 |
| February | 168.67 | 23.73 | 163.17 | 24.30 | 0.00 | 24.30 |
| March | 0.33 | 23.63 | 384.67 | 24.57 | 0.00 | 24.57 |
| April | 1.50 | 25.43 | 480.00 | 24.15 | 1.50 | 24.16 |
| May | 13.67 | 24.25 | 744.00 | 24.01 | 13.67 | 24.01 |
| June | 71.00 | 24.05 | 720.00 | 24.01 | 71.00 | 24.01 |
| July | 158.83 | 24.00 | 744.00 | 24.00 | 158.83 | 24.00 |
| August | 190.50 | 24.00 | 744.00 | 24.00 | 190.50 | 24.00 |
| September | 112.00 | 24.01 | 720.00 | 24.01 | 112.00 | 24.01 |
| October | 20.67 | 25.66 | 744.00 | 24.37 | 20.67 | 24.40 |
| November | 0.00 | 0.00 | 481.33 | 24.79 | 0.00 | 24.79 |
| December | 166.17 | 23.89 | 163.33 | 24.50 | 0.00 | 24.50 |
| Annual Sum or Average | 1438.17 | 23.74 | 6107.50 | 24.12 | 568.17 | 24.12 |
| Minimum of Months | 0.00 | 0.00 | 19.00 | 23.38 | 0.00 | 23.38 |
| Maximum of Months | 534.83 | 25.66 | 744.00 | 24.79 | 190.50 | 24.79 |
Report: ComfortReportSimple55Monthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 78.17 | 23.72 | 116.33 | 24.49 | 0.00 | 24.49 |
| February | 9.50 | 23.77 | 226.67 | 24.86 | 0.00 | 24.86 |
| March | 0.17 | 23.45 | 353.00 | 24.45 | 0.00 | 24.45 |
| April | 0.50 | 25.68 | 393.17 | 24.14 | 0.50 | 24.14 |
| May | 14.33 | 24.24 | 515.00 | 24.01 | 14.33 | 24.02 |
| June | 57.83 | 24.04 | 492.00 | 24.01 | 57.83 | 24.01 |
| July | 141.67 | 24.00 | 533.00 | 24.00 | 141.67 | 24.00 |
| August | 167.17 | 24.00 | 506.00 | 24.00 | 167.17 | 24.00 |
| September | 83.33 | 24.00 | 510.00 | 24.01 | 83.33 | 24.01 |
| October | 7.17 | 25.86 | 524.00 | 24.36 | 7.17 | 24.38 |
| November | 0.00 | 0.00 | 461.17 | 24.58 | 0.00 | 24.58 |
| December | 18.50 | 24.00 | 194.83 | 24.87 | 0.00 | 24.87 |
| Annual Sum or Average | 578.33 | 23.99 | 4825.17 | 24.22 | 472.00 | 24.20 |
| Minimum of Months | 0.00 | 0.00 | 116.33 | 24.00 | 0.00 | 24.00 |
| Maximum of Months | 167.17 | 25.86 | 533.00 | 24.87 | 167.17 | 24.87 |
Report: ComfortReportSimple55Monthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 89.17 | 23.69 | 113.33 | 24.43 | 0.00 | 24.43 |
| February | 9.67 | 23.80 | 233.83 | 24.85 | 0.00 | 24.85 |
| March | 0.17 | 23.44 | 374.33 | 24.46 | 0.00 | 24.46 |
| April | 0.00 | 0.00 | 439.83 | 24.14 | 0.00 | 24.14 |
| May | 9.50 | 24.34 | 515.00 | 24.01 | 9.50 | 24.02 |
| June | 39.83 | 24.05 | 492.00 | 24.01 | 39.83 | 24.01 |
| July | 50.50 | 24.00 | 533.00 | 24.00 | 50.50 | 24.00 |
| August | 56.00 | 24.00 | 506.00 | 24.00 | 56.00 | 24.00 |
| September | 29.33 | 24.00 | 510.00 | 24.01 | 29.33 | 24.01 |
| October | 4.67 | 25.99 | 524.00 | 24.38 | 4.67 | 24.40 |
| November | 0.00 | 0.00 | 470.83 | 24.60 | 0.00 | 24.60 |
| December | 18.50 | 24.00 | 199.17 | 24.86 | 0.00 | 24.86 |
| Annual Sum or Average | 307.33 | 23.95 | 4911.33 | 24.23 | 189.83 | 24.23 |
| Minimum of Months | 0.00 | 0.00 | 113.33 | 24.00 | 0.00 | 24.00 |
| Maximum of Months | 89.17 | 25.99 | 533.00 | 24.86 | 56.00 | 24.86 |
Report: ComfortReportSimple55Monthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 202.33 | 23.54 | 102.00 | 24.10 | 0.00 | 24.10 |
| February | 41.50 | 23.68 | 215.83 | 24.87 | 0.00 | 24.87 |
| March | 0.00 | 0.00 | 354.67 | 24.51 | 0.00 | 24.51 |
| April | 0.17 | 25.65 | 418.83 | 24.13 | 0.17 | 24.13 |
| May | 10.33 | 24.31 | 515.00 | 24.01 | 10.33 | 24.02 |
| June | 53.17 | 24.04 | 492.00 | 24.01 | 53.17 | 24.01 |
| July | 145.17 | 24.00 | 533.00 | 24.00 | 145.17 | 24.00 |
| August | 192.67 | 24.00 | 506.00 | 24.00 | 192.67 | 24.00 |
| September | 138.17 | 24.00 | 510.00 | 24.01 | 138.17 | 24.01 |
| October | 11.17 | 25.29 | 506.33 | 24.28 | 11.17 | 24.31 |
| November | 0.00 | 0.00 | 304.17 | 24.77 | 0.00 | 24.77 |
| December | 99.17 | 23.74 | 147.00 | 24.58 | 0.00 | 24.58 |
| Annual Sum or Average | 893.83 | 23.87 | 4604.83 | 24.19 | 550.83 | 24.17 |
| Minimum of Months | 0.00 | 0.00 | 102.00 | 24.00 | 0.00 | 24.00 |
| Maximum of Months | 202.33 | 25.65 | 533.00 | 24.87 | 192.67 | 24.87 |
Report: ComfortReportSimple55Monthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 584.83 | 23.06 | 29.00 | 23.15 | 0.00 | 23.15 |
| February | 159.17 | 23.53 | 221.33 | 24.47 | 0.00 | 24.47 |
| March | 0.17 | 23.72 | 488.83 | 24.56 | 0.00 | 24.56 |
| April | 0.83 | 25.66 | 570.83 | 24.13 | 0.83 | 24.13 |
| May | 10.00 | 24.32 | 744.00 | 24.01 | 10.00 | 24.01 |
| June | 59.50 | 24.05 | 720.00 | 24.01 | 59.50 | 24.01 |
| July | 180.67 | 24.00 | 744.00 | 24.00 | 180.67 | 24.00 |
| August | 234.50 | 24.00 | 744.00 | 24.00 | 234.50 | 24.00 |
| September | 187.83 | 24.01 | 720.00 | 24.01 | 187.83 | 24.01 |
| October | 28.83 | 25.21 | 696.00 | 24.30 | 28.83 | 24.34 |
| November | 22.17 | 23.91 | 327.83 | 24.82 | 0.00 | 24.82 |
| December | 421.33 | 23.52 | 106.33 | 23.85 | 0.00 | 23.85 |
| Annual Sum or Average | 1889.83 | 23.59 | 6112.17 | 24.06 | 702.17 | 24.06 |
| Minimum of Months | 0.17 | 23.06 | 29.00 | 23.15 | 0.00 | 23.15 |
| Maximum of Months | 584.83 | 25.66 | 744.00 | 24.82 | 234.50 | 24.82 |
Report: ComfortReportSimple55Monthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 202.33 | 23.54 | 99.33 | 24.09 | 0.00 | 24.09 |
| February | 39.50 | 23.68 | 219.17 | 24.88 | 0.00 | 24.88 |
| March | 0.00 | 0.00 | 350.17 | 24.54 | 0.00 | 24.54 |
| April | 0.17 | 25.78 | 407.67 | 24.13 | 0.17 | 24.13 |
| May | 10.17 | 24.32 | 515.00 | 24.01 | 10.17 | 24.02 |
| June | 55.00 | 24.04 | 492.00 | 24.01 | 55.00 | 24.01 |
| July | 146.00 | 24.00 | 533.00 | 24.00 | 146.00 | 24.00 |
| August | 194.67 | 24.00 | 506.00 | 24.00 | 194.67 | 24.00 |
| September | 143.33 | 24.01 | 510.00 | 24.01 | 143.33 | 24.01 |
| October | 11.00 | 25.39 | 505.33 | 24.29 | 11.00 | 24.31 |
| November | 0.00 | 0.00 | 303.00 | 24.78 | 0.00 | 24.78 |
| December | 101.17 | 23.75 | 147.83 | 24.59 | 0.00 | 24.59 |
| Annual Sum or Average | 903.33 | 23.88 | 4588.50 | 24.19 | 560.33 | 24.18 |
| Minimum of Months | 0.00 | 0.00 | 99.33 | 24.00 | 0.00 | 24.00 |
| Maximum of Months | 202.33 | 25.78 | 533.00 | 24.88 | 194.67 | 24.88 |
Report: ComfortReportSimple55Monthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 581.50 | 23.12 | 27.83 | 23.20 | 0.00 | 23.20 |
| February | 134.33 | 23.55 | 238.33 | 24.57 | 0.00 | 24.57 |
| March | 0.00 | 0.00 | 500.67 | 24.64 | 0.00 | 24.64 |
| April | 0.83 | 25.83 | 565.17 | 24.14 | 0.83 | 24.15 |
| May | 9.83 | 24.32 | 744.00 | 24.01 | 9.83 | 24.01 |
| June | 60.83 | 24.05 | 720.00 | 24.01 | 60.83 | 24.01 |
| July | 179.67 | 24.00 | 744.00 | 24.00 | 179.67 | 24.00 |
| August | 234.00 | 24.00 | 744.00 | 24.00 | 234.00 | 24.00 |
| September | 196.17 | 24.01 | 720.00 | 24.01 | 196.17 | 24.01 |
| October | 28.33 | 25.33 | 697.00 | 24.32 | 28.33 | 24.36 |
| November | 17.00 | 23.89 | 328.67 | 24.89 | 0.00 | 24.89 |
| December | 400.00 | 23.55 | 100.17 | 23.86 | 0.00 | 23.86 |
| Annual Sum or Average | 1842.50 | 23.62 | 6129.83 | 24.08 | 709.67 | 24.08 |
| Minimum of Months | 0.00 | 0.00 | 27.83 | 23.20 | 0.00 | 23.20 |
| Maximum of Months | 581.50 | 25.83 | 744.00 | 24.89 | 234.00 | 24.89 |
Report: ComfortReportSimple55Monthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 481.83 | 23.56 | 53.33 | 23.69 | 0.00 | 23.69 |
| February | 66.83 | 23.86 | 244.67 | 24.78 | 0.00 | 24.78 |
| March | 0.00 | 0.00 | 437.50 | 24.64 | 0.00 | 24.64 |
| April | 1.00 | 25.62 | 458.50 | 24.16 | 1.00 | 24.17 |
| May | 11.67 | 24.26 | 733.67 | 24.01 | 11.67 | 24.01 |
| June | 88.50 | 24.03 | 720.00 | 24.01 | 88.50 | 24.01 |
| July | 281.33 | 24.00 | 744.00 | 24.00 | 281.33 | 24.00 |
| August | 386.67 | 24.00 | 744.00 | 24.00 | 386.67 | 24.00 |
| September | 284.50 | 24.01 | 720.00 | 24.01 | 284.50 | 24.01 |
| October | 30.50 | 25.24 | 640.33 | 24.34 | 30.50 | 24.38 |
| November | 0.00 | 0.00 | 308.83 | 24.90 | 0.00 | 24.90 |
| December | 194.00 | 23.83 | 146.00 | 24.34 | 0.00 | 24.34 |
| Annual Sum or Average | 1826.83 | 23.89 | 5950.83 | 24.14 | 1084.17 | 24.13 |
| Minimum of Months | 0.00 | 0.00 | 53.33 | 23.69 | 0.00 | 23.69 |
| Maximum of Months | 481.83 | 25.62 | 744.00 | 24.90 | 386.67 | 24.90 |
Report: ComfortReportSimple55Monthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 480.17 | 23.56 | 53.67 | 23.69 | 0.00 | 23.69 |
| February | 65.67 | 23.86 | 246.50 | 24.79 | 0.00 | 24.79 |
| March | 0.00 | 0.00 | 439.67 | 24.64 | 0.00 | 24.64 |
| April | 1.00 | 25.62 | 459.33 | 24.16 | 1.00 | 24.17 |
| May | 11.67 | 24.26 | 733.83 | 24.01 | 11.67 | 24.01 |
| June | 88.33 | 24.03 | 720.00 | 24.01 | 88.33 | 24.01 |
| July | 281.67 | 24.00 | 744.00 | 24.00 | 281.67 | 24.00 |
| August | 386.67 | 24.00 | 744.00 | 24.00 | 386.67 | 24.00 |
| September | 284.50 | 24.01 | 720.00 | 24.01 | 284.50 | 24.01 |
| October | 30.50 | 25.25 | 642.17 | 24.34 | 30.50 | 24.38 |
| November | 0.00 | 0.00 | 310.33 | 24.90 | 0.00 | 24.90 |
| December | 193.33 | 23.83 | 147.83 | 24.35 | 0.00 | 24.35 |
| Annual Sum or Average | 1823.50 | 23.89 | 5961.33 | 24.14 | 1084.33 | 24.13 |
| Minimum of Months | 0.00 | 0.00 | 53.67 | 23.69 | 0.00 | 23.69 |
| Maximum of Months | 480.17 | 25.62 | 744.00 | 24.90 | 386.67 | 24.90 |
Report: ComfortReportSimple55Monthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 58.33 | 23.80 | 125.17 | 24.74 | 0.00 | 24.74 |
| February | 6.50 | 23.78 | 240.50 | 25.00 | 0.00 | 25.00 |
| March | 0.00 | 0.00 | 363.83 | 24.51 | 0.00 | 24.51 |
| April | 0.17 | 25.65 | 353.33 | 24.15 | 0.17 | 24.15 |
| May | 12.00 | 24.26 | 511.00 | 24.01 | 12.00 | 24.02 |
| June | 68.83 | 24.03 | 492.00 | 24.01 | 68.83 | 24.01 |
| July | 233.83 | 24.00 | 533.00 | 24.00 | 233.83 | 24.00 |
| August | 284.67 | 24.00 | 506.00 | 24.00 | 284.67 | 24.00 |
| September | 197.50 | 24.01 | 510.00 | 24.01 | 197.50 | 24.01 |
| October | 11.33 | 25.37 | 517.67 | 24.29 | 11.33 | 24.31 |
| November | 0.00 | 0.00 | 344.83 | 24.71 | 0.00 | 24.71 |
| December | 47.00 | 23.99 | 170.83 | 24.86 | 0.00 | 24.86 |
| Annual Sum or Average | 920.17 | 24.01 | 4668.17 | 24.22 | 808.33 | 24.19 |
| Minimum of Months | 0.00 | 0.00 | 125.17 | 24.00 | 0.00 | 24.00 |
| Maximum of Months | 284.67 | 25.65 | 533.00 | 25.00 | 284.67 | 25.00 |
Report: ComfortReportSimple55Monthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 58.17 | 23.80 | 125.50 | 24.74 | 0.00 | 24.74 |
| February | 6.50 | 23.78 | 241.00 | 25.00 | 0.00 | 25.00 |
| March | 0.00 | 0.00 | 364.17 | 24.51 | 0.00 | 24.51 |
| April | 0.17 | 25.65 | 353.83 | 24.15 | 0.17 | 24.15 |
| May | 12.00 | 24.26 | 510.33 | 24.01 | 12.00 | 24.02 |
| June | 69.33 | 24.03 | 492.00 | 24.01 | 69.33 | 24.01 |
| July | 233.83 | 24.00 | 533.00 | 24.00 | 233.83 | 24.00 |
| August | 284.67 | 24.00 | 506.00 | 24.00 | 284.67 | 24.00 |
| September | 197.67 | 24.01 | 510.00 | 24.01 | 197.67 | 24.01 |
| October | 11.33 | 25.37 | 517.67 | 24.29 | 11.33 | 24.31 |
| November | 0.00 | 0.00 | 344.50 | 24.71 | 0.00 | 24.71 |
| December | 46.83 | 23.99 | 171.00 | 24.86 | 0.00 | 24.86 |
| Annual Sum or Average | 920.50 | 24.01 | 4669.00 | 24.22 | 809.00 | 24.19 |
| Minimum of Months | 0.00 | 0.00 | 125.50 | 24.00 | 0.00 | 24.00 |
| Maximum of Months | 284.67 | 25.65 | 533.00 | 25.00 | 284.67 | 25.00 |
Report: ComfortReportSimple55Monthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 424.00 | 22.27 | 61.50 | 22.66 | 0.00 | 22.66 |
| February | 236.33 | 22.68 | 160.00 | 23.73 | 1.33 | 23.74 |
| March | 90.83 | 23.54 | 265.67 | 24.32 | 0.17 | 24.32 |
| April | 10.83 | 24.21 | 407.33 | 24.09 | 3.33 | 24.10 |
| May | 19.67 | 24.18 | 512.67 | 24.01 | 19.67 | 24.02 |
| June | 64.83 | 24.03 | 492.00 | 24.01 | 64.83 | 24.01 |
| July | 153.00 | 24.00 | 533.00 | 24.00 | 153.00 | 24.00 |
| August | 200.83 | 24.00 | 506.00 | 24.00 | 200.83 | 24.00 |
| September | 205.67 | 24.01 | 510.00 | 24.01 | 205.67 | 24.01 |
| October | 44.67 | 24.14 | 423.00 | 24.21 | 25.00 | 24.23 |
| November | 184.50 | 23.21 | 215.33 | 24.12 | 0.50 | 24.12 |
| December | 381.33 | 22.44 | 94.33 | 22.99 | 0.83 | 22.99 |
| Annual Sum or Average | 2016.50 | 23.10 | 4180.83 | 23.85 | 675.17 | 23.87 |
| Minimum of Months | 10.83 | 22.27 | 61.50 | 22.66 | 0.00 | 22.66 |
| Maximum of Months | 424.00 | 24.21 | 533.00 | 24.32 | 205.67 | 24.32 |
Report: ComfortReportSimple55Monthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 706.17 | 22.05 | 55.67 | 22.08 | 37.00 | 22.04 |
| February | 393.17 | 22.49 | 174.17 | 23.32 | 0.50 | 23.33 |
| March | 139.33 | 23.41 | 425.33 | 24.25 | 0.00 | 24.25 |
| April | 14.50 | 24.12 | 598.67 | 24.09 | 4.17 | 24.09 |
| May | 20.33 | 24.17 | 741.50 | 24.01 | 20.33 | 24.01 |
| June | 75.67 | 24.04 | 720.00 | 24.01 | 75.67 | 24.01 |
| July | 193.00 | 24.00 | 744.00 | 24.00 | 193.00 | 24.00 |
| August | 244.83 | 24.00 | 744.00 | 24.00 | 244.83 | 24.00 |
| September | 259.67 | 24.01 | 720.00 | 24.01 | 259.67 | 24.01 |
| October | 87.00 | 24.16 | 611.17 | 24.21 | 52.33 | 24.24 |
| November | 300.50 | 23.01 | 277.67 | 23.86 | 0.00 | 23.86 |
| December | 649.33 | 22.17 | 75.50 | 22.29 | 37.50 | 22.23 |
| Annual Sum or Average | 3083.50 | 22.86 | 5887.67 | 23.69 | 925.00 | 23.70 |
| Minimum of Months | 14.50 | 22.05 | 55.67 | 22.08 | 0.00 | 22.04 |
| Maximum of Months | 706.17 | 24.17 | 744.00 | 24.25 | 259.67 | 24.25 |
Report: ComfortReportSimple55Monthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 426.33 | 22.29 | 52.50 | 22.62 | 0.00 | 22.62 |
| February | 233.50 | 22.71 | 163.33 | 23.76 | 1.83 | 23.77 |
| March | 90.00 | 23.58 | 264.00 | 24.34 | 0.83 | 24.35 |
| April | 9.50 | 24.17 | 401.83 | 24.10 | 1.83 | 24.10 |
| May | 20.00 | 24.18 | 512.50 | 24.01 | 20.00 | 24.02 |
| June | 67.83 | 24.03 | 492.00 | 24.01 | 67.83 | 24.01 |
| July | 155.00 | 24.00 | 533.00 | 24.00 | 155.00 | 24.00 |
| August | 204.67 | 24.00 | 506.00 | 24.00 | 204.67 | 24.00 |
| September | 212.17 | 24.01 | 510.00 | 24.01 | 212.17 | 24.01 |
| October | 44.33 | 24.18 | 421.83 | 24.22 | 24.67 | 24.25 |
| November | 186.33 | 23.23 | 215.83 | 24.12 | 1.33 | 24.13 |
| December | 382.33 | 22.45 | 92.83 | 22.99 | 0.67 | 22.99 |
| Annual Sum or Average | 2032.00 | 23.12 | 4165.67 | 23.85 | 690.83 | 23.87 |
| Minimum of Months | 9.50 | 22.29 | 52.50 | 22.62 | 0.00 | 22.62 |
| Maximum of Months | 426.33 | 24.18 | 533.00 | 24.34 | 212.17 | 24.35 |
Report: ComfortReportSimple55Monthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 709.50 | 22.06 | 41.50 | 22.07 | 29.50 | 22.03 |
| February | 377.83 | 22.56 | 171.83 | 23.38 | 0.00 | 23.38 |
| March | 125.67 | 23.45 | 440.17 | 24.37 | 0.00 | 24.37 |
| April | 12.17 | 24.17 | 596.17 | 24.10 | 2.67 | 24.11 |
| May | 20.50 | 24.17 | 741.67 | 24.01 | 20.50 | 24.01 |
| June | 77.67 | 24.04 | 720.00 | 24.01 | 77.67 | 24.01 |
| July | 193.00 | 24.00 | 744.00 | 24.00 | 193.00 | 24.00 |
| August | 245.00 | 24.00 | 744.00 | 24.00 | 245.00 | 24.00 |
| September | 261.83 | 24.01 | 720.00 | 24.01 | 261.83 | 24.01 |
| October | 85.17 | 24.25 | 615.17 | 24.24 | 53.17 | 24.28 |
| November | 281.83 | 23.02 | 284.50 | 23.88 | 0.00 | 23.88 |
| December | 662.83 | 22.26 | 59.17 | 22.31 | 32.50 | 22.26 |
| Annual Sum or Average | 3053.00 | 22.89 | 5878.17 | 23.71 | 915.83 | 23.72 |
| Minimum of Months | 12.17 | 22.06 | 41.50 | 22.07 | 0.00 | 22.03 |
| Maximum of Months | 709.50 | 24.25 | 744.00 | 24.37 | 261.83 | 24.37 |
Report: ComfortReportSimple55Monthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 709.17 | 22.20 | 12.50 | 22.24 | 0.00 | 22.24 |
| February | 377.50 | 22.85 | 156.50 | 23.52 | 0.00 | 23.52 |
| March | 92.67 | 23.65 | 408.50 | 24.39 | 0.00 | 24.39 |
| April | 6.50 | 24.43 | 566.67 | 24.11 | 2.67 | 24.11 |
| May | 22.00 | 24.16 | 740.67 | 24.01 | 22.00 | 24.01 |
| June | 84.83 | 24.04 | 720.00 | 24.01 | 84.83 | 24.01 |
| July | 237.83 | 24.00 | 744.00 | 24.00 | 237.83 | 24.00 |
| August | 310.33 | 24.00 | 744.00 | 24.00 | 310.33 | 24.00 |
| September | 295.83 | 24.01 | 720.00 | 24.01 | 295.83 | 24.01 |
| October | 60.67 | 24.56 | 632.67 | 24.26 | 43.17 | 24.30 |
| November | 236.50 | 23.34 | 238.17 | 24.06 | 0.00 | 24.06 |
| December | 666.50 | 22.51 | 20.33 | 22.59 | 0.00 | 22.59 |
| Annual Sum or Average | 3100.33 | 23.08 | 5704.00 | 23.77 | 996.67 | 23.80 |
| Minimum of Months | 6.50 | 22.20 | 12.50 | 22.24 | 0.00 | 22.24 |
| Maximum of Months | 709.17 | 24.56 | 744.00 | 24.39 | 310.33 | 24.39 |
Report: ComfortReportSimple55Monthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 709.00 | 22.20 | 12.17 | 22.25 | 0.00 | 22.25 |
| February | 375.33 | 22.85 | 158.67 | 23.53 | 0.00 | 23.53 |
| March | 92.67 | 23.66 | 410.83 | 24.39 | 0.00 | 24.39 |
| April | 6.83 | 24.41 | 567.17 | 24.11 | 2.67 | 24.11 |
| May | 22.17 | 24.16 | 740.67 | 24.01 | 22.17 | 24.01 |
| June | 85.00 | 24.04 | 720.00 | 24.01 | 85.00 | 24.01 |
| July | 238.00 | 24.00 | 744.00 | 24.00 | 238.00 | 24.00 |
| August | 310.00 | 24.00 | 744.00 | 24.00 | 310.00 | 24.00 |
| September | 296.00 | 24.01 | 720.00 | 24.01 | 296.00 | 24.01 |
| October | 60.67 | 24.56 | 632.83 | 24.26 | 43.33 | 24.30 |
| November | 236.33 | 23.33 | 238.83 | 24.06 | 0.00 | 24.06 |
| December | 665.00 | 22.51 | 20.67 | 22.59 | 0.00 | 22.59 |
| Annual Sum or Average | 3097.00 | 23.08 | 5709.83 | 23.77 | 997.17 | 23.80 |
| Minimum of Months | 6.83 | 22.20 | 12.17 | 22.25 | 0.00 | 22.25 |
| Maximum of Months | 709.00 | 24.56 | 744.00 | 24.39 | 310.00 | 24.39 |
Report: ComfortReportSimple55Monthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 381.83 | 22.63 | 70.33 | 23.03 | 0.00 | 23.03 |
| February | 181.67 | 23.03 | 175.00 | 24.11 | 0.83 | 24.12 |
| March | 49.83 | 23.80 | 275.50 | 24.44 | 0.17 | 24.45 |
| April | 3.17 | 24.51 | 390.17 | 24.11 | 1.33 | 24.11 |
| May | 21.83 | 24.16 | 511.67 | 24.01 | 21.83 | 24.02 |
| June | 71.83 | 24.03 | 492.00 | 24.01 | 71.83 | 24.01 |
| July | 193.50 | 24.00 | 533.00 | 24.00 | 193.50 | 24.00 |
| August | 249.67 | 24.00 | 506.00 | 24.00 | 249.67 | 24.00 |
| September | 234.17 | 24.01 | 510.00 | 24.01 | 234.17 | 24.01 |
| October | 25.67 | 24.64 | 444.83 | 24.25 | 18.83 | 24.28 |
| November | 104.50 | 23.53 | 234.00 | 24.46 | 0.33 | 24.47 |
| December | 334.33 | 22.90 | 110.83 | 23.48 | 0.17 | 23.49 |
| Annual Sum or Average | 1852.00 | 23.41 | 4253.33 | 23.98 | 792.67 | 23.98 |
| Minimum of Months | 3.17 | 22.63 | 70.33 | 23.03 | 0.00 | 23.03 |
| Maximum of Months | 381.83 | 24.64 | 533.00 | 24.46 | 249.67 | 24.47 |
Report: ComfortReportSimple55Monthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 381.83 | 22.63 | 70.67 | 23.04 | 0.00 | 23.04 |
| February | 181.67 | 23.03 | 175.17 | 24.11 | 0.83 | 24.12 |
| March | 49.83 | 23.80 | 275.67 | 24.44 | 0.17 | 24.45 |
| April | 3.33 | 24.48 | 389.67 | 24.11 | 1.33 | 24.11 |
| May | 21.83 | 24.16 | 511.67 | 24.01 | 21.83 | 24.02 |
| June | 71.83 | 24.03 | 492.00 | 24.01 | 71.83 | 24.01 |
| July | 193.67 | 24.00 | 533.00 | 24.00 | 193.67 | 24.00 |
| August | 249.83 | 24.00 | 506.00 | 24.00 | 249.83 | 24.00 |
| September | 234.17 | 24.01 | 510.00 | 24.01 | 234.17 | 24.01 |
| October | 25.67 | 24.64 | 444.83 | 24.25 | 18.83 | 24.28 |
| November | 105.83 | 23.54 | 234.17 | 24.46 | 0.50 | 24.47 |
| December | 334.33 | 22.90 | 110.67 | 23.48 | 0.17 | 23.49 |
| Annual Sum or Average | 1853.83 | 23.41 | 4253.50 | 23.98 | 793.17 | 23.98 |
| Minimum of Months | 3.33 | 22.63 | 70.67 | 23.04 | 0.00 | 23.04 |
| Maximum of Months | 381.83 | 24.64 | 533.00 | 24.46 | 249.83 | 24.47 |
Report: ComfortReportSimple55Monthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 22.97 | 744.00 | 22.97 | 744.00 | 22.97 |
| February | 672.00 | 24.45 | 672.00 | 24.45 | 672.00 | 24.45 |
| March | 744.00 | 25.65 | 744.00 | 25.65 | 744.00 | 25.65 |
| April | 720.00 | 26.37 | 720.00 | 26.37 | 720.00 | 26.37 |
| May | 744.00 | 26.79 | 744.00 | 26.79 | 744.00 | 26.79 |
| June | 720.00 | 26.84 | 720.00 | 26.84 | 720.00 | 26.84 |
| July | 744.00 | 26.71 | 744.00 | 26.71 | 744.00 | 26.71 |
| August | 744.00 | 26.52 | 744.00 | 26.52 | 744.00 | 26.52 |
| September | 720.00 | 26.28 | 720.00 | 26.28 | 720.00 | 26.28 |
| October | 744.00 | 25.90 | 744.00 | 25.90 | 744.00 | 25.90 |
| November | 720.00 | 25.06 | 720.00 | 25.06 | 720.00 | 25.06 |
| December | 744.00 | 23.49 | 744.00 | 23.49 | 744.00 | 23.49 |
| Annual Sum or Average | 8760.00 | 25.59 | 8760.00 | 25.59 | 8760.00 | 25.59 |
| Minimum of Months | 672.00 | 22.97 | 672.00 | 22.97 | 672.00 | 22.97 |
| Maximum of Months | 744.00 | 26.84 | 744.00 | 26.84 | 744.00 | 26.84 |
Report: ComfortReportSimple55Monthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 397.83 | 23.01 | 270.83 | 23.74 | 77.00 | 23.74 |
| February | 202.67 | 24.33 | 515.50 | 25.34 | 120.83 | 25.41 |
| March | 286.67 | 26.80 | 716.50 | 26.72 | 270.83 | 26.80 |
| April | 593.83 | 28.24 | 719.00 | 28.13 | 593.83 | 28.17 |
| May | 744.00 | 28.90 | 744.00 | 28.90 | 744.00 | 28.90 |
| June | 720.00 | 29.02 | 720.00 | 29.02 | 720.00 | 29.02 |
| July | 744.00 | 28.72 | 744.00 | 28.72 | 744.00 | 28.72 |
| August | 744.00 | 28.43 | 744.00 | 28.43 | 744.00 | 28.43 |
| September | 720.00 | 28.20 | 720.00 | 28.20 | 720.00 | 28.20 |
| October | 683.17 | 27.83 | 742.50 | 27.75 | 683.17 | 27.78 |
| November | 241.67 | 26.45 | 685.67 | 26.58 | 219.83 | 26.65 |
| December | 233.67 | 23.89 | 516.50 | 25.03 | 105.17 | 25.12 |
| Annual Sum or Average | 6311.50 | 27.69 | 7838.50 | 27.65 | 5742.67 | 27.81 |
| Minimum of Months | 202.67 | 23.01 | 270.83 | 23.74 | 77.00 | 23.74 |
| Maximum of Months | 744.00 | 29.02 | 744.00 | 29.02 | 744.00 | 29.02 |
Report: ComfortReportSimple55Monthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
| January | 744.00 | 24.98 | 744.00 | 24.98 | 744.00 | 24.98 |
| February | 672.00 | 25.75 | 672.00 | 25.75 | 672.00 | 25.75 |
| March | 744.00 | 26.09 | 744.00 | 26.09 | 744.00 | 26.09 |
| April | 720.00 | 26.26 | 720.00 | 26.26 | 720.00 | 26.26 |
| May | 744.00 | 26.39 | 744.00 | 26.39 | 744.00 | 26.39 |
| June | 720.00 | 26.37 | 720.00 | 26.37 | 720.00 | 26.37 |
| July | 744.00 | 26.27 | 744.00 | 26.27 | 744.00 | 26.27 |
| August | 744.00 | 26.17 | 744.00 | 26.17 | 744.00 | 26.17 |
| September | 720.00 | 26.09 | 720.00 | 26.09 | 720.00 | 26.09 |
| October | 744.00 | 26.12 | 744.00 | 26.12 | 744.00 | 26.12 |
| November | 720.00 | 25.94 | 720.00 | 25.94 | 720.00 | 25.94 |
| December | 744.00 | 25.45 | 744.00 | 25.45 | 744.00 | 25.45 |
| Annual Sum or Average | 8760.00 | 25.99 | 8760.00 | 25.99 | 8760.00 | 25.99 |
| Minimum of Months | 672.00 | 24.98 | 672.00 | 24.98 | 672.00 | 24.98 |
| Maximum of Months | 744.00 | 26.39 | 744.00 | 26.39 | 744.00 | 26.39 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 133.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 154.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 154.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 147.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 140.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 1750.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 133.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 161.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_GS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MSE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_MS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TSE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_TS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 515.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 492.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 506.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 524.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 510.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 6145.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 473.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 533.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: OCCUP_M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
| January | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| February | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| March | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| April | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| May | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| June | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| July | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| August | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| September | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| October | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| November | 720.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| December | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Annual Sum or Average | 8760.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Minimum of Months | 672.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
| Maximum of Months | 744.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: SPLIT GSW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.426025E+09 | 0.108234E+09 | 255.41 | 0.410153E+09 | 15872453.48 | 0.00 | 1.00 | 03-JAN-14:22 | 0.00 | 01-JAN-00:10 | 6716.81 | 18-JAN-19:42 | 6571.19 | 19-JAN-15:32 | 861.64 | 18-JAN-19:42 | 1490.67 | 18-JAN-19:42 | 0.00 |
| February | 0.856535E+09 | 0.218187E+09 | 315.61 | 0.818477E+09 | 38057739.86 | 0.00 | 1.00 | 01-FEB-13:12 | 0.00 | 01-FEB-02:50 | 6941.09 | 25-FEB-19:22 | 6606.73 | 22-FEB-10:52 | 1558.00 | 25-FEB-19:23 | 1512.86 | 22-FEB-12:02 | 0.00 |
| March | 0.213660E+10 | 0.570912E+09 | 509.94 | 0.200776E+10 | 0.128840E+09 | 0.00 | 1.00 | 01-MAR-11:52 | 0.00 | 01-MAR-08:45 | 6943.96 | 18-MAR-11:12 | 6597.91 | 04-MAR-19:32 | 1682.90 | 18-MAR-11:12 | 1544.27 | 28-MAR-09:12 | 0.00 |
| April | 0.367283E+10 | 0.104971E+10 | 660.75 | 0.346200E+10 | 0.210825E+09 | 0.00 | 1.00 | 01-APR-07:52 | 0.00 | 01-APR-05:15 | 6969.64 | 24-APR-07:42 | 6578.29 | 09-APR-21:52 | 1885.18 | 24-APR-07:42 | 1542.25 | 24-APR-07:42 | 0.00 |
| May | 0.505306E+10 | 0.148875E+10 | 741.28 | 0.448854E+10 | 0.564513E+09 | 0.00 | 1.00 | 13-MAY-07:52 | 0.00 | 13-MAY-05:15 | 7056.50 | 13-MAY-07:52 | 4961.84 | 13-MAY-07:52 | 2202.33 | 13-MAY-07:53 | 1515.80 | 13-MAY-07:52 | 0.00 |
| June | 0.558893E+10 | 0.163672E+10 | 717.66 | 0.468138E+10 | 0.907554E+09 | 0.00 | 1.00 | 18-JUN-06:52 | 0.00 | 18-JUN-05:13 | 7063.61 | 18-JUN-06:52 | 5172.84 | 27-JUN-11:52 | 2222.79 | 18-JUN-06:53 | 1520.63 | 18-JUN-06:52 | 0.00 |
| July | 0.627964E+10 | 0.175435E+10 | 744.00 | 0.485185E+10 | 0.142779E+10 | 0.00 | 0.64 | 02-JUL-16:50 | 0.22 | 19-JUL-03:20 | 3569.12 | 02-JUL-17:10 | 3120.06 | 02-JUL-17:02 | 756.08 | 01-JUL-16:40 | 1110.10 | 02-JUL-16:50 | 0.00 |
| August | 0.620726E+10 | 0.168508E+10 | 744.00 | 0.472611E+10 | 0.148115E+10 | 0.00 | 0.59 | 06-AUG-16:40 | 0.25 | 24-AUG-04:00 | 3444.77 | 13-AUG-16:15 | 2887.27 | 06-AUG-16:40 | 836.39 | 12-AUG-09:50 | 998.35 | 07-AUG-16:01 | 0.00 |
| September | 0.561826E+10 | 0.150731E+10 | 717.20 | 0.445180E+10 | 0.116646E+10 | 0.00 | 1.00 | 27-SEP-07:12 | 0.00 | 27-SEP-05:13 | 6906.97 | 27-SEP-07:12 | 5577.94 | 29-SEP-06:22 | 1575.86 | 27-SEP-07:13 | 1528.81 | 27-SEP-07:12 | 0.00 |
| October | 0.433712E+10 | 0.115476E+10 | 603.03 | 0.392846E+10 | 0.408657E+09 | 0.00 | 1.00 | 01-OCT-07:52 | 0.00 | 01-OCT-05:13 | 7154.46 | 13-OCT-09:12 | 6607.69 | 24-OCT-20:52 | 2565.32 | 13-OCT-09:13 | 1541.81 | 02-OCT-07:32 | 0.00 |
| November | 0.254301E+10 | 0.658430E+09 | 491.58 | 0.241114E+10 | 0.131869E+09 | 0.00 | 1.00 | 01-NOV-10:02 | 0.00 | 01-NOV-05:13 | 6856.64 | 09-NOV-09:32 | 6610.33 | 29-NOV-10:52 | 1187.28 | 18-NOV-10:33 | 1543.00 | 09-NOV-10:32 | 0.00 |
| December | 0.100970E+10 | 0.258198E+09 | 450.04 | 0.975464E+09 | 34236017.33 | 0.00 | 1.00 | 01-DEC-11:02 | 0.00 | 01-DEC-08:45 | 6779.48 | 10-DEC-19:22 | 6600.70 | 09-DEC-19:12 | 1472.32 | 29-DEC-22:52 | 1493.65 | 10-DEC-19:22 | 0.00 |
| Annual Sum or Average | 0.437290E+11 | 0.120906E+11 | 6950.49 | 0.372131E+11 | 0.651583E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.426025E+09 | 0.108234E+09 | 255.41 | 0.410153E+09 | 15872453.48 | 0.00 | 0.59 | 0.00 | 3444.77 | 2887.27 | 756.08 | 998.35 | 0.00 | ||||||
| Maximum of Months | 0.627964E+10 | 0.175435E+10 | 744.00 | 0.485185E+10 | 0.148115E+10 | 0.00 | 1.00 | 0.25 | 7154.46 | 6610.33 | 2565.32 | 1544.27 | 0.00 |
Report: DXReportMonthly
For: SPLIT GNW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 17459077.06 | 4508575.37 | 35.00 | 15261277.52 | 2197799.53 | 0.00 | 0.82 | 14-JAN-22:52 | 0.00 | 01-JAN-00:10 | 5254.37 | 14-JAN-22:52 | 4713.21 | 14-JAN-22:52 | 541.15 | 14-JAN-22:52 | 1212.14 | 14-JAN-22:52 | 0.00 |
| February | 0.254345E+09 | 66083093.50 | 133.28 | 0.239363E+09 | 14982194.26 | 0.00 | 1.00 | 08-FEB-13:42 | 0.00 | 01-FEB-00:10 | 6873.98 | 25-FEB-17:02 | 6518.59 | 28-FEB-19:12 | 1584.61 | 25-FEB-17:03 | 1500.77 | 22-FEB-12:02 | 0.00 |
| March | 0.143289E+10 | 0.387181E+09 | 466.16 | 0.132875E+10 | 0.104138E+09 | 0.00 | 1.00 | 01-MAR-14:22 | 0.00 | 01-MAR-04:00 | 6857.87 | 18-MAR-11:52 | 6519.94 | 19-MAR-18:32 | 1603.28 | 18-MAR-11:52 | 1543.28 | 10-MAR-10:12 | 0.00 |
| April | 0.320658E+10 | 0.920688E+09 | 657.67 | 0.300427E+10 | 0.202306E+09 | 0.00 | 1.00 | 01-APR-07:52 | 0.00 | 01-APR-05:15 | 6918.05 | 24-APR-07:42 | 6509.84 | 09-APR-21:12 | 1931.81 | 24-APR-07:42 | 1529.53 | 24-APR-07:42 | 0.00 |
| May | 0.496689E+10 | 0.146290E+10 | 741.28 | 0.440085E+10 | 0.566043E+09 | 0.00 | 1.00 | 13-MAY-07:52 | 0.00 | 13-MAY-05:15 | 6981.65 | 13-MAY-07:52 | 4971.82 | 13-MAY-07:52 | 2118.28 | 13-MAY-07:53 | 1503.09 | 13-MAY-07:52 | 0.00 |
| June | 0.562333E+10 | 0.164520E+10 | 717.66 | 0.471080E+10 | 0.912535E+09 | 0.00 | 1.00 | 18-JUN-06:52 | 0.00 | 18-JUN-05:13 | 6998.86 | 18-JUN-06:52 | 5101.71 | 27-JUN-11:52 | 2178.61 | 18-JUN-06:53 | 1507.91 | 18-JUN-06:52 | 0.00 |
| July | 0.628929E+10 | 0.175590E+10 | 744.00 | 0.486083E+10 | 0.142847E+10 | 0.00 | 0.64 | 02-JUL-17:20 | 0.23 | 19-JUL-03:30 | 3554.01 | 02-JUL-17:20 | 3121.08 | 02-JUL-17:20 | 731.42 | 01-JUL-16:40 | 1101.95 | 02-JUL-17:20 | 0.00 |
| August | 0.613007E+10 | 0.166356E+10 | 744.00 | 0.464882E+10 | 0.148125E+10 | 0.00 | 0.59 | 07-AUG-17:10 | 0.26 | 24-AUG-04:00 | 3349.39 | 07-AUG-17:10 | 2824.07 | 07-AUG-17:10 | 788.61 | 12-AUG-09:50 | 985.09 | 07-AUG-17:10 | 0.00 |
| September | 0.521970E+10 | 0.140167E+10 | 717.05 | 0.406921E+10 | 0.115048E+10 | 0.00 | 1.00 | 27-SEP-07:12 | 0.00 | 27-SEP-05:13 | 6863.18 | 27-SEP-07:12 | 5474.13 | 29-SEP-06:22 | 1621.48 | 27-SEP-07:13 | 1516.48 | 27-SEP-07:12 | 0.00 |
| October | 0.335170E+10 | 0.899542E+09 | 589.53 | 0.297418E+10 | 0.377523E+09 | 0.00 | 1.00 | 01-OCT-08:22 | 0.00 | 01-OCT-05:13 | 7120.53 | 13-OCT-09:32 | 6411.28 | 24-OCT-10:02 | 2675.61 | 13-OCT-09:33 | 1542.37 | 09-OCT-09:22 | 0.00 |
| November | 0.140184E+10 | 0.369592E+09 | 435.59 | 0.130234E+10 | 99500493.12 | 0.00 | 1.00 | 01-NOV-11:02 | 0.00 | 01-NOV-05:13 | 6810.03 | 08-NOV-22:52 | 6536.17 | 01-NOV-20:22 | 1284.13 | 09-NOV-10:33 | 1536.98 | 04-NOV-10:52 | 0.00 |
| December | 0.181894E+09 | 47302093.27 | 190.71 | 0.172230E+09 | 9664101.23 | 0.00 | 1.00 | 01-DEC-15:41 | 0.00 | 01-DEC-08:35 | 6683.49 | 10-DEC-19:22 | 6504.22 | 03-DEC-19:42 | 1029.98 | 10-DEC-19:22 | 1479.37 | 10-DEC-19:22 | 0.00 |
| Annual Sum or Average | 0.380760E+11 | 0.106241E+11 | 6171.92 | 0.317269E+11 | 0.634909E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 17459077.06 | 4508575.37 | 35.00 | 15261277.52 | 2197799.53 | 0.00 | 0.59 | 0.00 | 3349.39 | 2824.07 | 541.15 | 985.09 | 0.00 | ||||||
| Maximum of Months | 0.628929E+10 | 0.175590E+10 | 744.00 | 0.486083E+10 | 0.148125E+10 | 0.00 | 1.00 | 0.26 | 7120.53 | 6536.17 | 2675.61 | 1543.28 | 0.00 |
Report: DXReportMonthly
For: SPLIT OFFICE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.708189E+09 | 0.184840E+09 | 169.23 | 0.690206E+09 | 17983272.22 | 0.00 | 0.54 | 26-JAN-07:01 | 0.00 | 01-JAN-00:10 | 3706.08 | 26-JAN-07:01 | 3294.07 | 26-JAN-07:01 | 412.01 | 26-JAN-07:01 | 907.51 | 26-JAN-07:01 | 0.00 |
| February | 0.108234E+10 | 0.278854E+09 | 183.60 | 0.103387E+10 | 48473596.84 | 0.00 | 1.00 | 09-FEB-07:01 | 0.00 | 01-FEB-00:10 | 7489.58 | 23-FEB-07:01 | 7088.94 | 21-FEB-07:01 | 867.72 | 09-FEB-07:01 | 1678.96 | 23-FEB-07:01 | 0.00 |
| March | 0.207972E+10 | 0.545919E+09 | 255.70 | 0.196331E+10 | 0.116412E+09 | 0.00 | 1.00 | 06-MAR-07:01 | 0.00 | 01-MAR-00:10 | 7876.89 | 29-MAR-06:01 | 7434.55 | 27-MAR-06:01 | 1868.65 | 29-MAR-06:04 | 1694.13 | 29-MAR-06:01 | 0.00 |
| April | 0.299701E+10 | 0.831992E+09 | 360.91 | 0.283353E+10 | 0.163479E+09 | 0.00 | 1.00 | 03-APR-06:01 | 0.00 | 01-APR-00:10 | 8160.69 | 26-APR-06:01 | 7638.47 | 21-APR-06:01 | 2815.95 | 26-APR-06:05 | 1869.01 | 27-APR-06:01 | 0.00 |
| May | 0.456201E+10 | 0.130252E+10 | 565.04 | 0.404568E+10 | 0.516326E+09 | 0.00 | 1.00 | 01-MAY-06:01 | 0.00 | 01-MAY-16:01 | 8486.37 | 24-MAY-06:01 | 7636.40 | 05-MAY-06:01 | 4216.91 | 23-MAY-06:06 | 1906.69 | 04-MAY-06:01 | 0.00 |
| June | 0.507555E+10 | 0.142442E+10 | 597.73 | 0.416539E+10 | 0.910165E+09 | 0.00 | 1.00 | 01-JUN-06:01 | 0.00 | 01-JUN-00:10 | 8473.92 | 28-JUN-06:04 | 7523.91 | 07-JUN-06:01 | 5017.91 | 28-JUN-06:07 | 1962.27 | 12-JUN-06:01 | 0.00 |
| July | 0.544952E+10 | 0.143957E+10 | 624.65 | 0.393740E+10 | 0.151212E+10 | 0.00 | 1.00 | 03-JUL-06:01 | 0.00 | 01-JUL-08:55 | 8486.96 | 26-JUL-06:01 | 5882.12 | 05-JUL-06:01 | 5111.85 | 13-JUL-06:07 | 1964.34 | 05-JUL-06:01 | 0.00 |
| August | 0.558525E+10 | 0.143325E+10 | 590.07 | 0.396773E+10 | 0.161751E+10 | 0.00 | 1.00 | 01-AUG-06:01 | 0.00 | 01-AUG-16:01 | 8497.30 | 16-AUG-06:02 | 5504.99 | 03-AUG-06:01 | 5197.62 | 30-AUG-06:08 | 1878.45 | 08-AUG-06:11 | 0.00 |
| September | 0.453891E+10 | 0.115961E+10 | 487.37 | 0.342872E+10 | 0.111019E+10 | 0.00 | 1.00 | 01-SEP-06:01 | 0.00 | 01-SEP-01:00 | 8497.37 | 07-SEP-06:02 | 5955.55 | 26-SEP-06:01 | 5075.67 | 12-SEP-06:09 | 1801.00 | 22-SEP-06:12 | 0.00 |
| October | 0.358125E+10 | 0.929854E+09 | 370.40 | 0.323337E+10 | 0.347878E+09 | 0.00 | 1.00 | 02-OCT-06:01 | 0.00 | 01-OCT-04:10 | 8323.55 | 04-OCT-06:01 | 7488.97 | 23-OCT-06:01 | 3431.25 | 12-OCT-06:05 | 1744.73 | 04-OCT-06:25 | 0.00 |
| November | 0.221098E+10 | 0.565873E+09 | 246.56 | 0.212032E+10 | 90654850.89 | 0.00 | 1.00 | 01-NOV-06:01 | 0.00 | 01-NOV-00:10 | 7801.54 | 09-NOV-07:01 | 7313.56 | 03-NOV-06:01 | 1660.67 | 09-NOV-07:03 | 1692.96 | 09-NOV-07:01 | 0.00 |
| December | 0.112040E+10 | 0.289239E+09 | 195.13 | 0.109952E+10 | 20881367.25 | 0.00 | 1.00 | 01-DEC-07:01 | 0.00 | 01-DEC-00:10 | 7348.32 | 29-DEC-07:01 | 7238.72 | 29-DEC-07:01 | 402.90 | 28-DEC-07:01 | 1668.04 | 29-DEC-07:01 | 0.00 |
| Annual Sum or Average | 0.389911E+11 | 0.103859E+11 | 4646.41 | 0.325191E+11 | 0.647208E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.708189E+09 | 0.184840E+09 | 169.23 | 0.690206E+09 | 17983272.22 | 0.00 | 0.54 | 0.00 | 3706.08 | 3294.07 | 402.90 | 907.51 | 0.00 | ||||||
| Maximum of Months | 0.558525E+10 | 0.143957E+10 | 624.65 | 0.416539E+10 | 0.161751E+10 | 0.00 | 1.00 | 0.00 | 8497.37 | 7638.47 | 5197.62 | 1964.34 | 0.00 |
Report: DXReportMonthly
For: SPLIT GNE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 16231167.80 | 4201895.61 | 35.89 | 14158910.79 | 2072257.00 | 0.00 | 0.80 | 14-JAN-22:52 | 0.00 | 01-JAN-00:10 | 4922.07 | 14-JAN-22:52 | 4408.77 | 14-JAN-22:52 | 513.30 | 14-JAN-22:52 | 1140.10 | 14-JAN-22:52 | 0.00 |
| February | 0.258471E+09 | 67152036.66 | 141.95 | 0.242562E+09 | 15908943.95 | 0.00 | 1.00 | 08-FEB-13:42 | 0.00 | 01-FEB-00:10 | 6636.85 | 25-FEB-17:02 | 6296.37 | 22-FEB-20:32 | 1558.00 | 25-FEB-17:02 | 1452.84 | 22-FEB-12:02 | 0.00 |
| March | 0.143054E+10 | 0.386005E+09 | 471.16 | 0.132395E+10 | 0.106600E+09 | 0.00 | 1.00 | 01-MAR-14:22 | 0.00 | 01-MAR-03:50 | 6635.22 | 18-MAR-11:52 | 6295.00 | 21-MAR-18:12 | 1531.64 | 29-MAR-09:23 | 1493.21 | 10-MAR-10:12 | 0.00 |
| April | 0.322717E+10 | 0.924185E+09 | 661.50 | 0.302095E+10 | 0.206223E+09 | 0.00 | 1.00 | 01-APR-07:52 | 0.00 | 01-APR-05:15 | 6697.45 | 24-APR-07:42 | 6288.63 | 11-APR-09:22 | 1923.42 | 24-APR-07:43 | 1478.96 | 24-APR-07:42 | 0.00 |
| May | 0.499607E+10 | 0.146793E+10 | 741.31 | 0.442781E+10 | 0.568266E+09 | 0.00 | 1.00 | 13-MAY-07:52 | 0.00 | 13-MAY-05:15 | 6755.16 | 13-MAY-07:52 | 4799.58 | 13-MAY-07:52 | 2056.37 | 13-MAY-07:53 | 1453.18 | 13-MAY-07:52 | 0.00 |
| June | 0.556855E+10 | 0.162600E+10 | 717.68 | 0.465714E+10 | 0.911406E+09 | 0.00 | 1.00 | 18-JUN-06:52 | 0.00 | 18-JUN-05:13 | 6770.25 | 18-JUN-06:52 | 4923.61 | 27-JUN-11:52 | 2120.26 | 18-JUN-06:53 | 1457.83 | 18-JUN-06:52 | 0.00 |
| July | 0.629337E+10 | 0.175330E+10 | 744.00 | 0.486424E+10 | 0.142913E+10 | 0.00 | 0.60 | 02-JUL-17:20 | 0.23 | 19-JUL-03:20 | 3255.61 | 01-JUL-17:10 | 2823.33 | 07-JUL-17:10 | 710.80 | 01-JUL-17:20 | 1001.35 | 02-JUL-17:20 | 0.00 |
| August | 0.613434E+10 | 0.166122E+10 | 744.00 | 0.465253E+10 | 0.148181E+10 | 0.00 | 0.57 | 07-AUG-17:10 | 0.26 | 24-AUG-04:00 | 3135.67 | 07-AUG-17:20 | 2622.06 | 07-AUG-17:10 | 794.26 | 12-AUG-09:50 | 924.35 | 07-AUG-17:10 | 0.00 |
| September | 0.520392E+10 | 0.139488E+10 | 717.09 | 0.405337E+10 | 0.115055E+10 | 0.00 | 1.00 | 27-SEP-07:12 | 0.00 | 27-SEP-05:13 | 6653.78 | 27-SEP-07:12 | 5283.23 | 29-SEP-06:22 | 1640.73 | 27-SEP-07:13 | 1466.65 | 27-SEP-07:12 | 0.00 |
| October | 0.336746E+10 | 0.902138E+09 | 587.89 | 0.298661E+10 | 0.380847E+09 | 0.00 | 1.00 | 01-OCT-08:22 | 0.00 | 01-OCT-05:13 | 6874.90 | 13-OCT-09:32 | 6191.43 | 24-OCT-21:42 | 2558.58 | 13-OCT-09:33 | 1490.66 | 09-OCT-09:22 | 0.00 |
| November | 0.139297E+10 | 0.366922E+09 | 441.93 | 0.129200E+10 | 0.100972E+09 | 0.00 | 1.00 | 01-NOV-11:02 | 0.00 | 01-NOV-05:13 | 6585.48 | 08-NOV-22:52 | 6319.25 | 01-NOV-20:22 | 1248.88 | 09-NOV-10:33 | 1486.48 | 04-NOV-10:52 | 0.00 |
| December | 0.176924E+09 | 46037767.24 | 196.80 | 0.167363E+09 | 9560794.17 | 0.00 | 1.00 | 01-DEC-15:41 | 0.00 | 01-DEC-08:45 | 6405.77 | 16-DEC-20:42 | 6282.51 | 03-DEC-19:42 | 916.42 | 10-DEC-19:22 | 1427.24 | 16-DEC-20:42 | 0.00 |
| Annual Sum or Average | 0.380660E+11 | 0.106000E+11 | 6201.19 | 0.317027E+11 | 0.636334E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 16231167.80 | 4201895.61 | 35.89 | 14158910.79 | 2072257.00 | 0.00 | 0.57 | 0.00 | 3135.67 | 2622.06 | 513.30 | 924.35 | 0.00 | ||||||
| Maximum of Months | 0.629337E+10 | 0.175330E+10 | 744.00 | 0.486424E+10 | 0.148181E+10 | 0.00 | 1.00 | 0.26 | 6874.90 | 6319.25 | 2558.58 | 1493.21 | 0.00 |
Report: DXReportMonthly
For: SPLIT GN1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 78333552.14 | 20272540.88 | 123.36 | 68801956.61 | 9531595.53 | 0.00 | 1.00 | 14-JAN-22:52 | 0.00 | 01-JAN-00:10 | 5637.91 | 14-JAN-22:52 | 5498.45 | 26-JAN-20:42 | 799.51 | 17-JAN-20:33 | 1259.03 | 14-JAN-22:52 | 0.00 |
| February | 0.336879E+09 | 87377672.66 | 224.12 | 0.310849E+09 | 26029533.81 | 0.00 | 1.00 | 08-FEB-13:42 | 0.00 | 01-FEB-00:10 | 5857.50 | 25-FEB-17:02 | 5559.70 | 28-FEB-19:12 | 1373.04 | 25-FEB-17:02 | 1280.49 | 22-FEB-12:02 | 0.00 |
| March | 0.135437E+10 | 0.363515E+09 | 478.91 | 0.124422E+10 | 0.110145E+09 | 0.00 | 1.00 | 01-MAR-14:22 | 0.00 | 01-MAR-08:45 | 5856.93 | 18-MAR-11:52 | 5556.76 | 21-MAR-18:12 | 1401.77 | 29-MAR-09:23 | 1317.15 | 10-MAR-10:12 | 0.00 |
| April | 0.268524E+10 | 0.767634E+09 | 657.72 | 0.249057E+10 | 0.194669E+09 | 0.00 | 1.00 | 01-APR-07:52 | 0.00 | 01-APR-05:15 | 5904.98 | 24-APR-07:42 | 5547.01 | 09-APR-21:12 | 1702.96 | 24-APR-07:43 | 1305.55 | 24-APR-07:42 | 0.00 |
| May | 0.410052E+10 | 0.120407E+10 | 741.25 | 0.356885E+10 | 0.531666E+09 | 0.00 | 1.00 | 13-MAY-07:52 | 0.00 | 13-MAY-05:15 | 5956.64 | 13-MAY-07:52 | 4240.86 | 13-MAY-07:52 | 1795.64 | 13-MAY-07:53 | 1282.97 | 13-MAY-07:52 | 0.00 |
| June | 0.465454E+10 | 0.135749E+10 | 717.52 | 0.379342E+10 | 0.861119E+09 | 0.00 | 1.00 | 18-JUN-06:52 | 0.00 | 18-JUN-05:13 | 5978.35 | 18-JUN-06:52 | 4286.50 | 27-JUN-11:52 | 1868.79 | 18-JUN-06:53 | 1287.10 | 18-JUN-06:52 | 0.00 |
| July | 0.531082E+10 | 0.147765E+10 | 744.00 | 0.397482E+10 | 0.133600E+10 | 0.00 | 0.56 | 02-JUL-17:30 | 0.25 | 19-JUL-03:00 | 2700.13 | 01-JUL-17:13 | 2235.25 | 04-JUL-17:30 | 673.00 | 01-JUL-17:13 | 821.02 | 02-JUL-17:20 | 0.00 |
| August | 0.520433E+10 | 0.140654E+10 | 744.00 | 0.381098E+10 | 0.139336E+10 | 0.00 | 0.52 | 07-AUG-17:20 | 0.27 | 24-AUG-04:00 | 2580.82 | 27-AUG-16:30 | 2066.39 | 07-AUG-17:20 | 722.19 | 12-AUG-09:40 | 753.70 | 07-AUG-17:20 | 0.00 |
| September | 0.441986E+10 | 0.118146E+10 | 717.14 | 0.333360E+10 | 0.108627E+10 | 0.00 | 1.00 | 27-SEP-07:12 | 0.00 | 27-SEP-05:13 | 5891.15 | 27-SEP-07:12 | 4590.40 | 29-SEP-06:22 | 1509.98 | 27-SEP-07:13 | 1295.32 | 27-SEP-07:12 | 0.00 |
| October | 0.284928E+10 | 0.761549E+09 | 591.03 | 0.248884E+10 | 0.360444E+09 | 0.00 | 1.00 | 01-OCT-08:22 | 0.00 | 01-OCT-05:13 | 6081.18 | 13-OCT-09:32 | 5473.85 | 24-OCT-21:42 | 2288.85 | 13-OCT-09:33 | 1316.66 | 09-OCT-09:22 | 0.00 |
| November | 0.132453E+10 | 0.347423E+09 | 433.70 | 0.122181E+10 | 0.102721E+09 | 0.00 | 1.00 | 01-NOV-11:02 | 0.00 | 01-NOV-05:13 | 5816.78 | 08-NOV-22:52 | 5579.69 | 01-NOV-20:22 | 1138.16 | 08-NOV-22:53 | 1311.76 | 04-NOV-10:52 | 0.00 |
| December | 0.354337E+09 | 92628668.48 | 356.01 | 0.333600E+09 | 20737117.44 | 0.00 | 1.00 | 01-DEC-15:41 | 0.00 | 01-DEC-08:45 | 5800.13 | 29-DEC-22:52 | 5551.61 | 03-DEC-19:42 | 1332.07 | 29-DEC-22:52 | 1266.49 | 29-DEC-22:52 | 0.00 |
| Annual Sum or Average | 0.326730E+11 | 0.906760E+10 | 6528.77 | 0.266404E+11 | 0.603268E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 78333552.14 | 20272540.88 | 123.36 | 68801956.61 | 9531595.53 | 0.00 | 0.52 | 0.00 | 2580.82 | 2066.39 | 673.00 | 753.70 | 0.00 | ||||||
| Maximum of Months | 0.531082E+10 | 0.147765E+10 | 744.00 | 0.397482E+10 | 0.139336E+10 | 0.00 | 1.00 | 0.27 | 6081.18 | 5579.69 | 2288.85 | 1317.15 | 0.00 |
Report: DXReportMonthly
For: SPLIT GN2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 78645491.22 | 20355072.90 | 123.89 | 69170819.79 | 9474671.43 | 0.00 | 1.00 | 14-JAN-22:52 | 0.00 | 01-JAN-00:10 | 5634.04 | 14-JAN-22:52 | 5494.92 | 26-JAN-20:42 | 795.11 | 17-JAN-20:33 | 1258.17 | 14-JAN-22:52 | 0.00 |
| February | 0.340188E+09 | 88227036.67 | 224.86 | 0.314175E+09 | 26013842.17 | 0.00 | 1.00 | 07-FEB-13:22 | 0.00 | 01-FEB-00:10 | 5853.78 | 25-FEB-17:02 | 5556.32 | 28-FEB-19:12 | 1365.30 | 25-FEB-17:02 | 1279.70 | 22-FEB-12:02 | 0.00 |
| March | 0.135778E+10 | 0.364379E+09 | 478.91 | 0.124820E+10 | 0.109576E+09 | 0.00 | 1.00 | 01-MAR-14:22 | 0.00 | 01-MAR-08:45 | 5853.18 | 18-MAR-11:52 | 5553.68 | 21-MAR-18:12 | 1395.11 | 29-MAR-09:23 | 1316.29 | 10-MAR-10:12 | 0.00 |
| April | 0.268615E+10 | 0.767825E+09 | 657.72 | 0.249242E+10 | 0.193728E+09 | 0.00 | 1.00 | 01-APR-07:52 | 0.00 | 01-APR-05:15 | 5901.42 | 24-APR-07:42 | 5543.73 | 09-APR-21:12 | 1697.31 | 24-APR-07:43 | 1304.67 | 24-APR-07:42 | 0.00 |
| May | 0.410022E+10 | 0.120390E+10 | 741.25 | 0.356994E+10 | 0.530276E+09 | 0.00 | 1.00 | 13-MAY-07:52 | 0.00 | 13-MAY-05:15 | 5953.00 | 13-MAY-07:52 | 4241.78 | 13-MAY-07:52 | 1791.49 | 13-MAY-07:53 | 1282.10 | 13-MAY-07:52 | 0.00 |
| June | 0.465109E+10 | 0.135639E+10 | 717.52 | 0.379152E+10 | 0.859573E+09 | 0.00 | 1.00 | 18-JUN-06:52 | 0.00 | 18-JUN-05:13 | 5975.01 | 18-JUN-06:52 | 4285.92 | 27-JUN-11:52 | 1866.07 | 18-JUN-06:53 | 1286.23 | 18-JUN-06:52 | 0.00 |
| July | 0.530939E+10 | 0.147710E+10 | 744.00 | 0.397487E+10 | 0.133452E+10 | 0.00 | 0.56 | 02-JUL-17:30 | 0.25 | 19-JUL-03:00 | 2696.68 | 01-JUL-17:13 | 2231.34 | 04-JUL-17:30 | 671.84 | 01-JUL-17:13 | 819.28 | 02-JUL-17:20 | 0.00 |
| August | 0.520305E+10 | 0.140603E+10 | 744.00 | 0.381111E+10 | 0.139194E+10 | 0.00 | 0.52 | 07-AUG-17:20 | 0.27 | 24-AUG-04:00 | 2578.35 | 27-AUG-16:30 | 2063.60 | 07-AUG-17:20 | 721.77 | 12-AUG-09:40 | 752.58 | 07-AUG-17:20 | 0.00 |
| September | 0.441787E+10 | 0.118080E+10 | 717.14 | 0.333300E+10 | 0.108487E+10 | 0.00 | 1.00 | 27-SEP-07:12 | 0.00 | 27-SEP-05:13 | 5887.89 | 27-SEP-07:12 | 4590.25 | 29-SEP-06:22 | 1506.96 | 27-SEP-07:13 | 1294.45 | 27-SEP-07:12 | 0.00 |
| October | 0.284991E+10 | 0.761636E+09 | 591.19 | 0.249062E+10 | 0.359281E+09 | 0.00 | 1.00 | 01-OCT-08:22 | 0.00 | 01-OCT-05:13 | 6077.17 | 13-OCT-09:32 | 5475.05 | 24-OCT-21:42 | 2284.27 | 13-OCT-09:33 | 1315.77 | 09-OCT-09:22 | 0.00 |
| November | 0.132625E+10 | 0.347836E+09 | 434.29 | 0.122422E+10 | 0.102034E+09 | 0.00 | 1.00 | 01-NOV-11:02 | 0.00 | 01-NOV-05:13 | 5813.38 | 08-NOV-22:52 | 5576.19 | 01-NOV-20:22 | 1134.01 | 08-NOV-22:53 | 1310.94 | 04-NOV-10:52 | 0.00 |
| December | 0.354622E+09 | 92698890.79 | 356.56 | 0.334154E+09 | 20467702.41 | 0.00 | 1.00 | 01-DEC-15:41 | 0.00 | 01-DEC-08:45 | 5796.22 | 29-DEC-22:52 | 5548.24 | 03-DEC-19:42 | 1325.47 | 29-DEC-22:52 | 1265.63 | 29-DEC-22:52 | 0.00 |
| Annual Sum or Average | 0.326751E+11 | 0.906717E+10 | 6531.33 | 0.266534E+11 | 0.602175E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 78645491.22 | 20355072.90 | 123.89 | 69170819.79 | 9474671.43 | 0.00 | 0.52 | 0.00 | 2578.35 | 2063.60 | 671.84 | 752.58 | 0.00 | ||||||
| Maximum of Months | 0.530939E+10 | 0.147710E+10 | 744.00 | 0.397487E+10 | 0.139194E+10 | 0.00 | 1.00 | 0.27 | 6077.17 | 5576.19 | 2284.27 | 1316.29 | 0.00 |
Report: DXReportMonthly
For: SPLIT GS1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.736954E+09 | 0.188894E+09 | 446.84 | 0.708143E+09 | 28811675.15 | 0.00 | 1.00 | 03-JAN-14:22 | 0.00 | 01-JAN-00:10 | 5844.39 | 17-JAN-20:33 | 5682.23 | 13-JAN-12:52 | 1003.98 | 17-JAN-20:33 | 1285.18 | 17-JAN-20:33 | 0.00 |
| February | 0.108080E+10 | 0.275186E+09 | 401.76 | 0.102729E+10 | 53509941.00 | 0.00 | 1.00 | 01-FEB-13:12 | 0.00 | 01-FEB-10:30 | 5973.24 | 25-FEB-19:22 | 5681.54 | 22-FEB-10:52 | 1398.88 | 25-FEB-19:23 | 1301.13 | 22-FEB-12:02 | 0.00 |
| March | 0.209654E+10 | 0.556030E+09 | 515.47 | 0.196142E+10 | 0.135124E+09 | 0.00 | 1.00 | 01-MAR-11:52 | 0.00 | 01-MAR-09:00 | 5982.83 | 18-MAR-11:12 | 5675.47 | 04-MAR-19:32 | 1486.97 | 18-MAR-11:13 | 1328.32 | 28-MAR-09:12 | 0.00 |
| April | 0.317239E+10 | 0.902823E+09 | 661.53 | 0.296813E+10 | 0.204254E+09 | 0.00 | 1.00 | 01-APR-07:52 | 0.00 | 01-APR-05:15 | 5994.71 | 24-APR-07:42 | 5659.86 | 09-APR-20:52 | 1671.82 | 24-APR-07:43 | 1326.43 | 24-APR-07:42 | 0.00 |
| May | 0.420103E+10 | 0.123446E+10 | 741.25 | 0.367064E+10 | 0.530390E+09 | 0.00 | 1.00 | 13-MAY-07:52 | 0.00 | 13-MAY-05:15 | 6066.65 | 13-MAY-07:52 | 4270.44 | 13-MAY-07:52 | 1877.38 | 13-MAY-07:53 | 1303.67 | 13-MAY-07:52 | 0.00 |
| June | 0.463058E+10 | 0.135220E+10 | 717.52 | 0.377504E+10 | 0.855542E+09 | 0.00 | 1.00 | 18-JUN-06:52 | 0.00 | 18-JUN-05:13 | 6079.23 | 18-JUN-06:52 | 4386.26 | 27-JUN-11:52 | 1916.81 | 18-JUN-06:53 | 1307.83 | 18-JUN-06:52 | 0.00 |
| July | 0.531311E+10 | 0.147973E+10 | 744.00 | 0.397803E+10 | 0.133509E+10 | 0.00 | 0.55 | 02-JUL-17:10 | 0.24 | 19-JUL-03:00 | 2726.45 | 01-JUL-17:02 | 2221.86 | 04-JUL-17:12 | 689.19 | 01-JUL-17:02 | 826.87 | 02-JUL-17:10 | 0.00 |
| August | 0.529550E+10 | 0.143223E+10 | 744.00 | 0.390088E+10 | 0.139462E+10 | 0.00 | 0.54 | 27-AUG-16:02 | 0.27 | 24-AUG-04:00 | 2755.73 | 27-AUG-16:02 | 2117.53 | 07-AUG-17:20 | 769.32 | 12-AUG-09:50 | 787.71 | 27-AUG-16:02 | 0.00 |
| September | 0.483983E+10 | 0.129348E+10 | 717.18 | 0.373268E+10 | 0.110715E+10 | 0.00 | 1.00 | 27-SEP-07:12 | 0.00 | 27-SEP-05:13 | 5958.65 | 27-SEP-07:12 | 4746.82 | 29-SEP-06:22 | 1416.02 | 27-SEP-07:13 | 1315.44 | 27-SEP-07:12 | 0.00 |
| October | 0.386045E+10 | 0.102352E+10 | 603.39 | 0.346456E+10 | 0.395888E+09 | 0.00 | 1.00 | 01-OCT-07:52 | 0.00 | 01-OCT-05:13 | 6148.18 | 13-OCT-09:12 | 5679.26 | 24-OCT-20:52 | 2174.47 | 13-OCT-09:13 | 1326.47 | 02-OCT-07:32 | 0.00 |
| November | 0.249973E+10 | 0.643488E+09 | 492.57 | 0.236413E+10 | 0.135609E+09 | 0.00 | 1.00 | 01-NOV-10:02 | 0.00 | 01-NOV-05:13 | 5895.16 | 09-NOV-09:32 | 5683.44 | 29-NOV-10:52 | 1052.65 | 09-NOV-09:33 | 1327.03 | 09-NOV-10:32 | 0.00 |
| December | 0.131557E+10 | 0.336427E+09 | 494.18 | 0.127253E+10 | 43038613.94 | 0.00 | 1.00 | 01-DEC-11:02 | 0.00 | 01-DEC-08:45 | 5919.35 | 29-DEC-22:52 | 5683.85 | 15-DEC-16:42 | 1196.75 | 29-DEC-22:52 | 1287.59 | 29-DEC-22:52 | 0.00 |
| Annual Sum or Average | 0.390425E+11 | 0.107185E+11 | 7279.67 | 0.328235E+11 | 0.621903E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.736954E+09 | 0.188894E+09 | 401.76 | 0.708143E+09 | 28811675.15 | 0.00 | 0.54 | 0.00 | 2726.45 | 2117.53 | 689.19 | 787.71 | 0.00 | ||||||
| Maximum of Months | 0.531311E+10 | 0.147973E+10 | 744.00 | 0.397803E+10 | 0.139462E+10 | 0.00 | 1.00 | 0.27 | 6148.18 | 5683.85 | 2174.47 | 1328.32 | 0.00 |
Report: DXReportMonthly
For: SPLIT GS2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.724191E+09 | 0.185612E+09 | 439.41 | 0.695594E+09 | 28597635.71 | 0.00 | 1.00 | 03-JAN-14:22 | 0.00 | 01-JAN-00:10 | 5895.22 | 17-JAN-20:33 | 5733.59 | 13-JAN-12:52 | 1008.20 | 17-JAN-20:33 | 1296.26 | 17-JAN-20:33 | 0.00 |
| February | 0.111045E+10 | 0.282724E+09 | 402.35 | 0.105567E+10 | 54776865.99 | 0.00 | 1.00 | 01-FEB-13:12 | 0.00 | 01-FEB-10:30 | 6014.16 | 25-FEB-19:22 | 5730.82 | 13-FEB-18:12 | 1406.25 | 25-FEB-19:23 | 1312.22 | 22-FEB-12:02 | 0.00 |
| March | 0.222058E+10 | 0.587994E+09 | 521.54 | 0.208098E+10 | 0.139607E+09 | 0.00 | 1.00 | 01-MAR-11:52 | 0.00 | 01-MAR-09:00 | 6038.61 | 18-MAR-11:12 | 5724.42 | 04-MAR-19:32 | 1479.28 | 18-MAR-11:13 | 1339.93 | 28-MAR-09:12 | 0.00 |
| April | 0.343368E+10 | 0.973365E+09 | 663.89 | 0.322238E+10 | 0.211304E+09 | 0.00 | 1.00 | 01-APR-07:52 | 0.00 | 01-APR-05:15 | 6032.12 | 24-APR-07:42 | 5718.52 | 09-APR-21:52 | 1566.80 | 24-APR-07:43 | 1337.44 | 24-APR-07:42 | 0.00 |
| May | 0.453378E+10 | 0.132726E+10 | 741.50 | 0.399015E+10 | 0.543627E+09 | 0.00 | 1.00 | 13-MAY-07:52 | 0.00 | 13-MAY-05:15 | 6106.55 | 13-MAY-07:52 | 4390.39 | 13-MAY-07:52 | 1802.84 | 13-MAY-07:53 | 1314.85 | 13-MAY-07:52 | 0.00 |
| June | 0.495472E+10 | 0.144240E+10 | 717.77 | 0.408171E+10 | 0.873012E+09 | 0.00 | 1.00 | 18-JUN-06:52 | 0.00 | 18-JUN-05:13 | 6111.04 | 18-JUN-06:52 | 4508.49 | 27-JUN-11:52 | 1842.31 | 18-JUN-06:53 | 1319.03 | 18-JUN-06:52 | 0.00 |
| July | 0.567842E+10 | 0.157782E+10 | 744.00 | 0.431798E+10 | 0.136044E+10 | 0.00 | 0.58 | 02-JUL-17:10 | 0.27 | 19-JUL-03:00 | 2882.78 | 01-JUL-17:02 | 2388.39 | 02-JUL-17:10 | 696.69 | 01-JUL-17:02 | 878.42 | 02-JUL-17:10 | 0.00 |
| August | 0.564221E+10 | 0.152304E+10 | 744.00 | 0.422222E+10 | 0.141999E+10 | 0.00 | 0.57 | 27-AUG-16:02 | 0.29 | 24-AUG-04:00 | 2933.01 | 27-AUG-16:02 | 2279.97 | 06-AUG-16:40 | 781.01 | 12-AUG-09:50 | 835.70 | 27-AUG-16:02 | 0.00 |
| September | 0.517382E+10 | 0.137960E+10 | 717.27 | 0.404417E+10 | 0.112964E+10 | 0.00 | 1.00 | 27-SEP-07:12 | 0.00 | 27-SEP-05:13 | 5992.74 | 27-SEP-07:12 | 4838.76 | 29-SEP-06:22 | 1354.90 | 27-SEP-07:13 | 1326.22 | 27-SEP-07:12 | 0.00 |
| October | 0.412262E+10 | 0.108984E+10 | 604.44 | 0.371777E+10 | 0.404851E+09 | 0.00 | 1.00 | 01-OCT-07:52 | 0.00 | 01-OCT-05:13 | 6179.69 | 13-OCT-09:12 | 5733.29 | 24-OCT-20:52 | 2109.46 | 13-OCT-09:13 | 1336.67 | 02-OCT-07:32 | 0.00 |
| November | 0.263972E+10 | 0.678467E+09 | 491.42 | 0.249993E+10 | 0.139790E+09 | 0.00 | 1.00 | 01-NOV-10:02 | 0.00 | 01-NOV-05:13 | 5942.41 | 09-NOV-09:32 | 5733.99 | 28-NOV-13:22 | 1049.95 | 09-NOV-09:33 | 1338.24 | 09-NOV-10:32 | 0.00 |
| December | 0.133567E+10 | 0.341594E+09 | 493.69 | 0.129235E+10 | 43316019.06 | 0.00 | 1.00 | 01-DEC-11:02 | 0.00 | 01-DEC-08:45 | 5970.96 | 29-DEC-22:52 | 5733.00 | 15-DEC-16:42 | 1201.05 | 29-DEC-22:52 | 1298.68 | 29-DEC-22:52 | 0.00 |
| Annual Sum or Average | 0.415699E+11 | 0.113897E+11 | 7281.27 | 0.352209E+11 | 0.634895E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.724191E+09 | 0.185612E+09 | 402.35 | 0.695594E+09 | 28597635.71 | 0.00 | 0.57 | 0.00 | 2882.78 | 2279.97 | 696.69 | 835.70 | 0.00 | ||||||
| Maximum of Months | 0.567842E+10 | 0.157782E+10 | 744.00 | 0.431798E+10 | 0.141999E+10 | 0.00 | 1.00 | 0.29 | 6179.69 | 5733.99 | 2109.46 | 1339.93 | 0.00 |
Report: DXReportMonthly
For: SPLIT MSW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.116973E+10 | 0.298784E+09 | 288.54 | 0.113353E+10 | 36205686.91 | 0.00 | 1.00 | 03-JAN-14:22 | 0.00 | 01-JAN-00:10 | 14828.23 | 18-JAN-19:42 | 14531.96 | 19-JAN-15:32 | 1829.55 | 18-JAN-19:42 | 3287.87 | 18-JAN-19:42 | 0.00 |
| February | 0.248701E+10 | 0.634123E+09 | 370.47 | 0.238239E+10 | 0.104621E+09 | 0.00 | 1.00 | 01-FEB-13:12 | 0.00 | 01-FEB-03:30 | 15233.92 | 25-FEB-19:22 | 14574.26 | 27-FEB-21:02 | 3139.97 | 25-FEB-19:22 | 3335.97 | 22-FEB-12:02 | 0.00 |
| March | 0.569630E+10 | 0.151303E+10 | 528.21 | 0.539461E+10 | 0.301689E+09 | 0.00 | 1.00 | 01-MAR-11:52 | 0.00 | 01-MAR-09:00 | 15347.76 | 18-MAR-11:12 | 14563.91 | 22-MAR-20:02 | 3480.97 | 18-MAR-11:12 | 3405.16 | 28-MAR-09:12 | 0.00 |
| April | 0.875828E+10 | 0.249465E+10 | 663.39 | 0.830742E+10 | 0.450861E+09 | 0.00 | 1.00 | 01-APR-07:52 | 0.00 | 01-APR-05:15 | 15339.41 | 24-APR-07:42 | 14523.04 | 09-APR-21:52 | 3918.27 | 24-APR-07:42 | 3399.88 | 24-APR-07:42 | 0.00 |
| May | 0.110020E+11 | 0.324678E+10 | 741.28 | 0.982311E+10 | 0.117892E+10 | 0.00 | 1.00 | 13-MAY-07:52 | 0.00 | 13-MAY-05:15 | 15572.07 | 13-MAY-07:52 | 10838.10 | 13-MAY-07:52 | 4733.97 | 13-MAY-07:52 | 3342.38 | 13-MAY-07:52 | 0.00 |
| June | 0.113561E+11 | 0.334355E+10 | 717.41 | 0.950707E+10 | 0.184906E+10 | 0.00 | 1.00 | 18-JUN-06:52 | 0.00 | 18-JUN-05:13 | 15634.34 | 18-JUN-06:52 | 11211.59 | 27-JUN-11:52 | 5108.00 | 18-JUN-06:52 | 3352.99 | 18-JUN-06:52 | 0.00 |
| July | 0.119320E+11 | 0.335821E+10 | 744.00 | 0.904857E+10 | 0.288346E+10 | 0.00 | 0.60 | 02-JUL-16:40 | 0.17 | 19-JUL-03:00 | 7290.59 | 01-JUL-16:30 | 6330.50 | 02-JUL-16:40 | 1585.07 | 01-JUL-16:01 | 2275.59 | 02-JUL-16:40 | 0.00 |
| August | 0.112559E+11 | 0.308163E+10 | 744.00 | 0.832228E+10 | 0.293359E+10 | 0.00 | 0.53 | 06-AUG-16:13 | 0.18 | 24-AUG-04:00 | 6849.37 | 13-AUG-16:15 | 5631.03 | 06-AUG-16:30 | 1732.83 | 12-AUG-10:00 | 1981.58 | 06-AUG-16:13 | 0.00 |
| September | 0.100367E+11 | 0.271847E+10 | 716.72 | 0.775882E+10 | 0.227787E+10 | 0.00 | 1.00 | 27-SEP-07:12 | 0.00 | 27-SEP-05:13 | 15363.63 | 27-SEP-07:12 | 11701.54 | 29-SEP-06:22 | 3918.52 | 27-SEP-07:12 | 3374.82 | 27-SEP-07:12 | 0.00 |
| October | 0.788937E+10 | 0.212270E+10 | 600.58 | 0.710889E+10 | 0.780485E+09 | 0.00 | 1.00 | 01-OCT-07:52 | 0.00 | 01-OCT-05:13 | 15937.79 | 13-OCT-09:12 | 14564.58 | 24-OCT-20:52 | 6499.33 | 13-OCT-09:13 | 3403.38 | 02-OCT-07:32 | 0.00 |
| November | 0.472147E+10 | 0.122885E+10 | 496.31 | 0.448405E+10 | 0.237417E+09 | 0.00 | 1.00 | 01-NOV-10:02 | 0.00 | 01-NOV-05:13 | 15149.29 | 09-NOV-09:32 | 14571.99 | 15-NOV-10:42 | 2578.14 | 09-NOV-09:32 | 3404.06 | 09-NOV-10:32 | 0.00 |
| December | 0.189251E+10 | 0.482760E+09 | 413.43 | 0.183308E+10 | 59434630.07 | 0.00 | 1.00 | 01-DEC-11:02 | 0.00 | 01-DEC-08:45 | 14952.03 | 10-DEC-19:22 | 14553.47 | 09-DEC-19:12 | 1923.28 | 10-DEC-19:22 | 3293.66 | 10-DEC-19:22 | 0.00 |
| Annual Sum or Average | 0.881974E+11 | 0.245235E+11 | 7024.34 | 0.751038E+11 | 0.130936E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.116973E+10 | 0.298784E+09 | 288.54 | 0.113353E+10 | 36205686.91 | 0.00 | 0.53 | 0.00 | 6849.37 | 5631.03 | 1585.07 | 1981.58 | 0.00 | ||||||
| Maximum of Months | 0.119320E+11 | 0.335821E+10 | 744.00 | 0.982311E+10 | 0.293359E+10 | 0.00 | 1.00 | 0.18 | 15937.79 | 14574.26 | 6499.33 | 3405.16 | 0.00 |
Report: DXReportMonthly
For: SPLIT MNW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 91109599.81 | 23631380.97 | 61.81 | 81503605.41 | 9605994.40 | 0.00 | 1.00 | 14-JAN-22:52 | 0.00 | 01-JAN-00:10 | 14591.97 | 14-JAN-22:52 | 13247.70 | 14-JAN-22:52 | 1344.27 | 14-JAN-22:52 | 3257.63 | 14-JAN-22:52 | 0.00 |
| February | 0.100256E+10 | 0.260103E+09 | 230.86 | 0.939109E+09 | 63452473.11 | 0.00 | 1.00 | 05-FEB-15:32 | 0.00 | 01-FEB-00:10 | 15238.17 | 25-FEB-22:52 | 14414.11 | 28-FEB-19:12 | 3721.66 | 25-FEB-22:52 | 3312.41 | 22-FEB-12:02 | 0.00 |
| March | 0.418230E+10 | 0.112164E+10 | 495.33 | 0.391689E+10 | 0.265416E+09 | 0.00 | 1.00 | 01-MAR-14:22 | 0.00 | 01-MAR-08:45 | 15185.46 | 18-MAR-11:52 | 14453.09 | 22-MAR-20:12 | 3249.71 | 18-MAR-11:52 | 3407.41 | 10-MAR-10:12 | 0.00 |
| April | 0.776186E+10 | 0.222030E+10 | 661.28 | 0.732313E+10 | 0.438722E+09 | 0.00 | 1.00 | 01-APR-07:52 | 0.00 | 01-APR-05:15 | 15244.91 | 24-APR-07:42 | 14378.43 | 09-APR-21:12 | 3993.59 | 24-APR-07:42 | 3376.75 | 24-APR-07:42 | 0.00 |
| May | 0.108062E+11 | 0.318842E+10 | 741.28 | 0.962221E+10 | 0.118395E+10 | 0.00 | 1.00 | 13-MAY-07:52 | 0.00 | 13-MAY-05:15 | 15431.74 | 13-MAY-07:52 | 10855.07 | 13-MAY-07:52 | 4576.67 | 13-MAY-07:52 | 3319.28 | 13-MAY-07:52 | 0.00 |
| June | 0.114037E+11 | 0.335528E+10 | 717.41 | 0.954392E+10 | 0.185980E+10 | 0.00 | 1.00 | 18-JUN-06:52 | 0.00 | 18-JUN-05:13 | 15511.65 | 18-JUN-06:52 | 11070.74 | 27-JUN-11:52 | 5023.72 | 18-JUN-06:52 | 3329.89 | 18-JUN-06:52 | 0.00 |
| July | 0.119238E+11 | 0.335460E+10 | 744.00 | 0.903859E+10 | 0.288517E+10 | 0.00 | 0.59 | 02-JUL-17:10 | 0.17 | 19-JUL-03:00 | 7148.62 | 02-JUL-17:20 | 6263.16 | 02-JUL-17:10 | 1531.25 | 01-JUL-16:13 | 2238.25 | 02-JUL-17:10 | 0.00 |
| August | 0.110639E+11 | 0.302834E+10 | 744.00 | 0.813255E+10 | 0.293132E+10 | 0.00 | 0.52 | 07-AUG-16:13 | 0.19 | 24-AUG-04:00 | 6465.64 | 07-AUG-16:13 | 5413.06 | 07-AUG-16:17 | 1629.40 | 12-AUG-10:00 | 1935.84 | 07-AUG-16:13 | 0.00 |
| September | 0.916521E+10 | 0.248325E+10 | 716.75 | 0.692888E+10 | 0.223633E+10 | 0.00 | 1.00 | 27-SEP-07:12 | 0.00 | 27-SEP-05:13 | 15272.98 | 27-SEP-07:12 | 11429.57 | 29-SEP-06:22 | 4092.52 | 27-SEP-07:12 | 3351.88 | 27-SEP-07:12 | 0.00 |
| October | 0.580726E+10 | 0.157466E+10 | 580.81 | 0.509905E+10 | 0.708211E+09 | 0.00 | 1.00 | 01-OCT-08:22 | 0.00 | 01-OCT-05:13 | 15863.33 | 13-OCT-09:32 | 14142.56 | 24-OCT-21:42 | 6682.35 | 13-OCT-09:33 | 3406.97 | 09-OCT-09:22 | 0.00 |
| November | 0.231796E+10 | 0.615344E+09 | 408.90 | 0.215421E+10 | 0.163752E+09 | 0.00 | 1.00 | 01-NOV-11:02 | 0.00 | 01-NOV-05:03 | 15015.89 | 08-NOV-22:52 | 14422.46 | 29-NOV-18:02 | 2853.76 | 09-NOV-10:32 | 3392.20 | 04-NOV-10:52 | 0.00 |
| December | 0.254129E+09 | 65846955.75 | 113.93 | 0.240463E+09 | 13665957.80 | 0.00 | 1.00 | 01-DEC-15:41 | 0.00 | 01-DEC-04:10 | 14647.40 | 16-DEC-20:42 | 14327.03 | 03-DEC-19:42 | 1742.83 | 10-DEC-19:22 | 3260.92 | 16-DEC-20:42 | 0.00 |
| Annual Sum or Average | 0.757799E+11 | 0.212914E+11 | 6216.35 | 0.630205E+11 | 0.127594E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 91109599.81 | 23631380.97 | 61.81 | 81503605.41 | 9605994.40 | 0.00 | 0.52 | 0.00 | 6465.64 | 5413.06 | 1344.27 | 1935.84 | 0.00 | ||||||
| Maximum of Months | 0.119238E+11 | 0.335528E+10 | 744.00 | 0.962221E+10 | 0.293132E+10 | 0.00 | 1.00 | 0.19 | 15863.33 | 14453.09 | 6682.35 | 3407.41 | 0.00 |
Report: DXReportMonthly
For: SPLIT MSE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.120274E+10 | 0.307654E+09 | 297.10 | 0.116569E+10 | 37056943.09 | 0.00 | 1.00 | 03-JAN-14:22 | 0.00 | 01-JAN-00:10 | 14231.11 | 14-JAN-22:52 | 14019.11 | 13-JAN-12:52 | 1747.39 | 18-JAN-19:42 | 3165.46 | 14-JAN-22:52 | 0.00 |
| February | 0.253951E+10 | 0.646606E+09 | 370.92 | 0.243116E+10 | 0.108356E+09 | 0.00 | 1.00 | 01-FEB-13:12 | 0.00 | 01-FEB-03:10 | 14720.69 | 25-FEB-19:22 | 14045.92 | 20-FEB-12:02 | 3165.23 | 25-FEB-19:22 | 3215.38 | 22-FEB-12:02 | 0.00 |
| March | 0.571971E+10 | 0.151566E+10 | 531.51 | 0.541138E+10 | 0.308334E+09 | 0.00 | 1.00 | 01-MAR-11:52 | 0.00 | 01-MAR-09:00 | 14785.71 | 18-MAR-11:12 | 14030.02 | 22-MAR-20:02 | 3608.03 | 18-MAR-11:13 | 3281.88 | 28-MAR-09:12 | 0.00 |
| April | 0.880485E+10 | 0.250048E+10 | 666.28 | 0.834551E+10 | 0.459335E+09 | 0.00 | 1.00 | 01-APR-07:52 | 0.00 | 01-APR-05:15 | 14799.56 | 24-APR-07:42 | 13987.55 | 09-APR-21:52 | 3927.50 | 24-APR-07:43 | 3277.06 | 24-APR-07:42 | 0.00 |
| May | 0.110670E+11 | 0.325721E+10 | 741.28 | 0.988165E+10 | 0.118538E+10 | 0.00 | 1.00 | 13-MAY-07:52 | 0.00 | 13-MAY-05:15 | 15012.76 | 13-MAY-07:52 | 10455.22 | 13-MAY-07:52 | 4787.24 | 13-MAY-07:53 | 3221.17 | 13-MAY-07:52 | 0.00 |
| June | 0.112395E+11 | 0.330227E+10 | 717.41 | 0.939100E+10 | 0.184855E+10 | 0.00 | 1.00 | 18-JUN-06:52 | 0.00 | 18-JUN-05:13 | 15072.62 | 18-JUN-06:52 | 10789.78 | 27-JUN-11:52 | 5017.87 | 18-JUN-06:53 | 3231.38 | 18-JUN-06:52 | 0.00 |
| July | 0.119422E+11 | 0.335424E+10 | 744.00 | 0.905565E+10 | 0.288653E+10 | 0.00 | 0.55 | 01-JUL-16:01 | 0.17 | 19-JUL-03:00 | 6765.36 | 01-JUL-16:01 | 5471.62 | 02-JUL-16:30 | 1517.84 | 01-JUL-16:01 | 2018.70 | 01-JUL-16:01 | 0.00 |
| August | 0.112668E+11 | 0.307854E+10 | 744.00 | 0.833041E+10 | 0.293642E+10 | 0.00 | 0.51 | 27-AUG-16:02 | 0.19 | 24-AUG-04:00 | 6374.98 | 27-AUG-16:02 | 5106.64 | 07-AUG-16:01 | 1749.29 | 12-AUG-10:00 | 1835.57 | 27-AUG-16:02 | 0.00 |
| September | 0.100060E+11 | 0.270497E+10 | 716.72 | 0.772667E+10 | 0.227930E+10 | 0.00 | 1.00 | 27-SEP-07:12 | 0.00 | 27-SEP-05:13 | 14817.93 | 27-SEP-07:12 | 11242.71 | 29-SEP-06:22 | 3783.96 | 27-SEP-07:12 | 3252.70 | 27-SEP-07:12 | 0.00 |
| October | 0.793581E+10 | 0.212978E+10 | 603.72 | 0.714607E+10 | 0.789733E+09 | 0.00 | 1.00 | 01-OCT-07:52 | 0.00 | 01-OCT-05:13 | 15359.62 | 13-OCT-09:12 | 14025.38 | 24-OCT-20:52 | 6122.35 | 13-OCT-09:13 | 3280.85 | 02-OCT-07:32 | 0.00 |
| November | 0.471426E+10 | 0.122433E+10 | 494.31 | 0.447223E+10 | 0.242027E+09 | 0.00 | 1.00 | 01-NOV-10:02 | 0.00 | 01-NOV-05:13 | 14589.21 | 09-NOV-09:32 | 14041.08 | 13-NOV-10:12 | 2577.68 | 09-NOV-09:33 | 3279.17 | 09-NOV-10:32 | 0.00 |
| December | 0.191027E+10 | 0.487080E+09 | 417.14 | 0.184933E+10 | 60939393.77 | 0.00 | 1.00 | 01-DEC-11:02 | 0.00 | 01-DEC-08:45 | 14411.80 | 10-DEC-19:22 | 14041.64 | 15-DEC-13:12 | 1985.91 | 10-DEC-19:22 | 3174.31 | 10-DEC-19:22 | 0.00 |
| Annual Sum or Average | 0.883487E+11 | 0.245088E+11 | 7044.39 | 0.752068E+11 | 0.131420E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.120274E+10 | 0.307654E+09 | 297.10 | 0.116569E+10 | 37056943.09 | 0.00 | 0.51 | 0.00 | 6374.98 | 5106.64 | 1517.84 | 1835.57 | 0.00 | ||||||
| Maximum of Months | 0.119422E+11 | 0.335424E+10 | 744.00 | 0.988165E+10 | 0.293642E+10 | 0.00 | 1.00 | 0.19 | 15359.62 | 14045.92 | 6122.35 | 3281.88 | 0.00 |
Report: DXReportMonthly
For: SPLIT MNE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 87884006.41 | 22822008.05 | 62.01 | 78407769.32 | 9476237.09 | 0.00 | 1.00 | 14-JAN-22:52 | 0.00 | 01-JAN-00:10 | 14044.15 | 14-JAN-22:52 | 12730.26 | 14-JAN-22:52 | 1313.88 | 14-JAN-22:52 | 3136.38 | 14-JAN-22:52 | 0.00 |
| February | 0.102103E+10 | 0.264859E+09 | 240.66 | 0.955948E+09 | 65084407.60 | 0.00 | 1.00 | 05-FEB-15:32 | 0.00 | 01-FEB-00:10 | 14606.16 | 25-FEB-17:02 | 13877.81 | 28-FEB-19:12 | 3067.35 | 25-FEB-22:52 | 3194.72 | 22-FEB-12:02 | 0.00 |
| March | 0.418526E+10 | 0.112086E+10 | 503.29 | 0.391372E+10 | 0.271549E+09 | 0.00 | 1.00 | 01-MAR-14:22 | 0.00 | 01-MAR-09:00 | 14618.13 | 18-MAR-11:52 | 13902.72 | 21-MAR-19:42 | 3250.74 | 18-MAR-11:53 | 3282.23 | 10-MAR-10:12 | 0.00 |
| April | 0.780689E+10 | 0.222671E+10 | 663.89 | 0.736015E+10 | 0.446737E+09 | 0.00 | 1.00 | 01-APR-07:52 | 0.00 | 01-APR-05:15 | 14704.28 | 24-APR-07:42 | 13842.12 | 09-APR-21:12 | 4001.64 | 24-APR-07:43 | 3252.16 | 24-APR-07:42 | 0.00 |
| May | 0.108704E+11 | 0.319850E+10 | 741.28 | 0.968156E+10 | 0.118883E+10 | 0.00 | 1.00 | 13-MAY-07:52 | 0.00 | 13-MAY-05:15 | 14866.66 | 13-MAY-07:52 | 10457.56 | 13-MAY-07:52 | 4639.16 | 13-MAY-07:53 | 3196.15 | 13-MAY-07:52 | 0.00 |
| June | 0.112861E+11 | 0.331337E+10 | 717.41 | 0.942835E+10 | 0.185780E+10 | 0.00 | 1.00 | 18-JUN-06:52 | 0.00 | 18-JUN-05:13 | 14942.01 | 18-JUN-06:52 | 10648.13 | 27-JUN-11:52 | 4912.41 | 18-JUN-06:53 | 3206.34 | 18-JUN-06:52 | 0.00 |
| July | 0.119330E+11 | 0.335006E+10 | 744.00 | 0.904624E+10 | 0.288674E+10 | 0.00 | 0.54 | 02-JUL-17:20 | 0.17 | 19-JUL-03:00 | 6572.49 | 01-JUL-16:13 | 5460.07 | 07-JUL-16:20 | 1473.41 | 17-JUL-17:20 | 1977.24 | 02-JUL-17:20 | 0.00 |
| August | 0.110741E+11 | 0.302497E+10 | 744.00 | 0.814129E+10 | 0.293283E+10 | 0.00 | 0.50 | 07-AUG-16:20 | 0.19 | 24-AUG-04:00 | 5963.59 | 27-AUG-16:02 | 4926.32 | 07-AUG-16:20 | 1650.54 | 12-AUG-10:10 | 1782.37 | 07-AUG-16:10 | 0.00 |
| September | 0.913444E+10 | 0.247032E+10 | 716.72 | 0.689755E+10 | 0.223689E+10 | 0.00 | 1.00 | 27-SEP-07:12 | 0.00 | 27-SEP-05:13 | 14719.51 | 27-SEP-07:12 | 10971.62 | 29-SEP-06:22 | 3950.50 | 27-SEP-07:12 | 3227.81 | 27-SEP-07:12 | 0.00 |
| October | 0.584485E+10 | 0.158144E+10 | 584.72 | 0.512728E+10 | 0.717572E+09 | 0.00 | 1.00 | 01-OCT-08:22 | 0.00 | 01-OCT-05:13 | 15281.41 | 13-OCT-09:32 | 13605.74 | 24-OCT-10:02 | 6285.93 | 13-OCT-09:33 | 3281.25 | 09-OCT-09:22 | 0.00 |
| November | 0.227212E+10 | 0.602633E+09 | 411.92 | 0.210674E+10 | 0.165378E+09 | 0.00 | 1.00 | 01-NOV-11:02 | 0.00 | 01-NOV-05:03 | 14475.46 | 08-NOV-22:52 | 13882.40 | 01-NOV-20:22 | 2746.61 | 09-NOV-10:33 | 3271.22 | 04-NOV-10:52 | 0.00 |
| December | 0.232489E+09 | 60283318.86 | 113.40 | 0.219828E+09 | 12661195.41 | 0.00 | 1.00 | 01-DEC-15:41 | 0.00 | 01-DEC-03:20 | 14083.29 | 16-DEC-20:42 | 13738.55 | 01-DEC-20:12 | 1455.94 | 10-DEC-19:22 | 3138.74 | 16-DEC-20:42 | 0.00 |
| Annual Sum or Average | 0.757486E+11 | 0.212368E+11 | 6243.30 | 0.629571E+11 | 0.127915E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 87884006.41 | 22822008.05 | 62.01 | 78407769.32 | 9476237.09 | 0.00 | 0.50 | 0.00 | 5963.59 | 4926.32 | 1313.88 | 1782.37 | 0.00 | ||||||
| Maximum of Months | 0.119330E+11 | 0.335006E+10 | 744.00 | 0.968156E+10 | 0.293283E+10 | 0.00 | 1.00 | 0.19 | 15281.41 | 13902.72 | 6285.93 | 3282.23 | 0.00 |
Report: DXReportMonthly
For: SPLIT MN1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.320754E+09 | 83392330.71 | 176.24 | 0.289611E+09 | 31143401.74 | 0.00 | 1.00 | 13-JAN-22:52 | 0.00 | 01-JAN-00:10 | 12275.84 | 14-JAN-22:52 | 11981.78 | 27-JAN-19:02 | 1770.10 | 17-JAN-20:33 | 2735.68 | 14-JAN-22:52 | 0.00 |
| February | 0.121256E+10 | 0.314207E+09 | 311.51 | 0.112616E+10 | 86399175.44 | 0.00 | 1.00 | 01-FEB-20:12 | 0.00 | 01-FEB-00:10 | 12745.76 | 25-FEB-17:02 | 12085.89 | 28-FEB-19:12 | 2951.51 | 25-FEB-17:03 | 2779.02 | 22-FEB-12:02 | 0.00 |
| March | 0.361489E+10 | 0.964731E+09 | 491.84 | 0.335528E+10 | 0.259602E+09 | 0.00 | 1.00 | 01-MAR-14:22 | 0.00 | 01-MAR-09:00 | 12741.29 | 18-MAR-11:52 | 12132.33 | 21-MAR-21:22 | 2960.49 | 29-MAR-09:23 | 2859.40 | 10-MAR-10:12 | 0.00 |
| April | 0.608791E+10 | 0.173776E+10 | 660.83 | 0.567863E+10 | 0.409290E+09 | 0.00 | 1.00 | 01-APR-07:52 | 0.00 | 01-APR-05:15 | 12800.61 | 24-APR-07:42 | 12049.20 | 09-APR-21:12 | 3593.57 | 24-APR-07:43 | 2834.04 | 24-APR-07:42 | 0.00 |
| May | 0.849263E+10 | 0.250082E+10 | 741.28 | 0.740613E+10 | 0.108649E+10 | 0.00 | 1.00 | 13-MAY-07:52 | 0.00 | 13-MAY-05:15 | 12947.91 | 13-MAY-07:52 | 9058.78 | 13-MAY-07:52 | 4064.43 | 13-MAY-07:53 | 2785.61 | 13-MAY-07:52 | 0.00 |
| June | 0.912144E+10 | 0.267505E+10 | 717.44 | 0.739541E+10 | 0.172604E+10 | 0.00 | 1.00 | 18-JUN-06:52 | 0.00 | 18-JUN-05:13 | 13015.46 | 18-JUN-06:52 | 9121.14 | 27-JUN-11:52 | 4417.66 | 18-JUN-06:53 | 2794.53 | 18-JUN-06:52 | 0.00 |
| July | 0.992412E+10 | 0.277994E+10 | 744.00 | 0.726884E+10 | 0.265528E+10 | 0.00 | 0.50 | 02-JUL-17:40 | 0.19 | 19-JUL-03:00 | 5299.68 | 01-JUL-17:13 | 4217.35 | 02-JUL-17:40 | 1358.37 | 01-JUL-17:13 | 1587.57 | 02-JUL-17:30 | 0.00 |
| August | 0.938422E+10 | 0.255433E+10 | 744.00 | 0.665721E+10 | 0.272701E+10 | 0.00 | 0.45 | 07-AUG-17:20 | 0.21 | 24-AUG-04:00 | 4889.86 | 27-AUG-16:15 | 3779.44 | 07-AUG-17:20 | 1456.31 | 12-AUG-10:00 | 1417.24 | 07-AUG-17:10 | 0.00 |
| September | 0.779249E+10 | 0.209772E+10 | 716.72 | 0.569615E+10 | 0.209634E+10 | 0.00 | 1.00 | 27-SEP-07:12 | 0.00 | 27-SEP-05:13 | 12837.34 | 27-SEP-07:12 | 9497.53 | 29-SEP-06:22 | 3625.97 | 27-SEP-07:13 | 2813.40 | 27-SEP-07:12 | 0.00 |
| October | 0.496999E+10 | 0.133895E+10 | 580.75 | 0.428945E+10 | 0.680542E+09 | 0.00 | 1.00 | 01-OCT-08:22 | 0.00 | 01-OCT-05:13 | 13307.52 | 13-OCT-09:32 | 11733.43 | 24-OCT-21:42 | 5537.53 | 13-OCT-09:33 | 2859.22 | 09-OCT-09:22 | 0.00 |
| November | 0.228595E+10 | 0.603452E+09 | 435.18 | 0.210146E+10 | 0.184488E+09 | 0.00 | 1.00 | 01-NOV-11:02 | 0.00 | 01-NOV-05:13 | 12627.67 | 08-NOV-22:52 | 12095.62 | 01-NOV-20:22 | 2520.15 | 17-NOV-22:52 | 2846.32 | 04-NOV-10:52 | 0.00 |
| December | 0.626770E+09 | 0.163665E+09 | 329.73 | 0.588627E+09 | 38142918.15 | 0.00 | 1.00 | 01-DEC-15:41 | 0.00 | 01-DEC-08:45 | 12398.67 | 10-DEC-19:22 | 12039.48 | 03-DEC-19:42 | 2405.63 | 29-DEC-22:52 | 2742.22 | 10-DEC-19:22 | 0.00 |
| Annual Sum or Average | 0.638337E+11 | 0.178140E+11 | 6649.53 | 0.518530E+11 | 0.119808E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.320754E+09 | 83392330.71 | 176.24 | 0.289611E+09 | 31143401.74 | 0.00 | 0.45 | 0.00 | 4889.86 | 3779.44 | 1358.37 | 1417.24 | 0.00 | ||||||
| Maximum of Months | 0.992412E+10 | 0.277994E+10 | 744.00 | 0.740613E+10 | 0.272701E+10 | 0.00 | 1.00 | 0.21 | 13307.52 | 12132.33 | 5537.53 | 2859.40 | 0.00 |
Report: DXReportMonthly
For: SPLIT MN2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.322587E+09 | 83875457.45 | 177.79 | 0.291394E+09 | 31192309.92 | 0.00 | 1.00 | 13-JAN-22:52 | 0.00 | 01-JAN-00:10 | 12266.82 | 14-JAN-22:52 | 11974.07 | 27-JAN-19:02 | 1775.71 | 17-JAN-20:33 | 2733.69 | 14-JAN-22:52 | 0.00 |
| February | 0.122126E+10 | 0.316439E+09 | 312.50 | 0.113451E+10 | 86755081.25 | 0.00 | 1.00 | 01-FEB-20:12 | 0.00 | 01-FEB-00:10 | 12737.00 | 25-FEB-17:02 | 12077.13 | 28-FEB-19:12 | 2947.35 | 25-FEB-17:03 | 2777.16 | 22-FEB-12:02 | 0.00 |
| March | 0.362602E+10 | 0.967601E+09 | 492.20 | 0.336599E+10 | 0.260034E+09 | 0.00 | 1.00 | 01-MAR-14:22 | 0.00 | 01-MAR-09:00 | 12731.60 | 18-MAR-11:52 | 12121.79 | 21-MAR-21:22 | 2955.89 | 29-MAR-09:23 | 2857.39 | 10-MAR-10:12 | 0.00 |
| April | 0.609235E+10 | 0.173896E+10 | 660.83 | 0.568282E+10 | 0.409532E+09 | 0.00 | 1.00 | 01-APR-07:52 | 0.00 | 01-APR-05:15 | 12791.53 | 24-APR-07:42 | 12040.10 | 09-APR-21:12 | 3589.16 | 24-APR-07:43 | 2831.99 | 24-APR-07:42 | 0.00 |
| May | 0.849520E+10 | 0.250155E+10 | 741.28 | 0.740858E+10 | 0.108662E+10 | 0.00 | 1.00 | 13-MAY-07:52 | 0.00 | 13-MAY-05:15 | 12938.54 | 13-MAY-07:52 | 9051.61 | 13-MAY-07:52 | 4061.93 | 13-MAY-07:53 | 2783.59 | 13-MAY-07:52 | 0.00 |
| June | 0.911820E+10 | 0.267407E+10 | 717.44 | 0.739232E+10 | 0.172588E+10 | 0.00 | 1.00 | 18-JUN-06:52 | 0.00 | 18-JUN-05:13 | 13006.22 | 18-JUN-06:52 | 9113.41 | 27-JUN-11:52 | 4416.91 | 18-JUN-06:53 | 2792.50 | 18-JUN-06:52 | 0.00 |
| July | 0.992465E+10 | 0.278001E+10 | 744.00 | 0.726931E+10 | 0.265534E+10 | 0.00 | 0.50 | 02-JUL-17:40 | 0.19 | 19-JUL-03:00 | 5293.56 | 01-JUL-17:13 | 4206.05 | 02-JUL-17:40 | 1357.03 | 01-JUL-17:13 | 1583.86 | 02-JUL-17:30 | 0.00 |
| August | 0.938491E+10 | 0.255444E+10 | 744.00 | 0.665782E+10 | 0.272709E+10 | 0.00 | 0.45 | 07-AUG-17:20 | 0.21 | 24-AUG-04:00 | 4886.33 | 27-AUG-16:15 | 3773.27 | 07-AUG-17:20 | 1456.66 | 12-AUG-10:00 | 1415.25 | 07-AUG-17:10 | 0.00 |
| September | 0.779180E+10 | 0.209750E+10 | 716.72 | 0.569550E+10 | 0.209630E+10 | 0.00 | 1.00 | 27-SEP-07:12 | 0.00 | 27-SEP-05:13 | 12828.26 | 27-SEP-07:12 | 9489.01 | 29-SEP-06:22 | 3628.49 | 27-SEP-07:13 | 2811.36 | 27-SEP-07:12 | 0.00 |
| October | 0.497544E+10 | 0.134038E+10 | 580.75 | 0.429452E+10 | 0.680922E+09 | 0.00 | 1.00 | 01-OCT-08:22 | 0.00 | 01-OCT-05:13 | 13298.13 | 13-OCT-09:32 | 11723.98 | 24-OCT-21:42 | 5532.09 | 13-OCT-09:33 | 2857.16 | 09-OCT-09:22 | 0.00 |
| November | 0.229093E+10 | 0.604749E+09 | 435.35 | 0.210625E+10 | 0.184675E+09 | 0.00 | 1.00 | 01-NOV-11:02 | 0.00 | 01-NOV-05:13 | 12618.47 | 08-NOV-22:52 | 12086.51 | 01-NOV-20:22 | 2518.80 | 17-NOV-22:52 | 2844.39 | 04-NOV-10:52 | 0.00 |
| December | 0.628227E+09 | 0.164048E+09 | 330.14 | 0.590037E+09 | 38189764.44 | 0.00 | 1.00 | 01-DEC-15:41 | 0.00 | 01-DEC-08:45 | 12389.24 | 10-DEC-19:22 | 12030.08 | 03-DEC-19:42 | 2401.28 | 29-DEC-22:52 | 2740.21 | 10-DEC-19:22 | 0.00 |
| Annual Sum or Average | 0.638716E+11 | 0.178236E+11 | 6653.00 | 0.518890E+11 | 0.119825E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.322587E+09 | 83875457.45 | 177.79 | 0.291394E+09 | 31192309.92 | 0.00 | 0.45 | 0.00 | 4886.33 | 3773.27 | 1357.03 | 1415.25 | 0.00 | ||||||
| Maximum of Months | 0.992465E+10 | 0.278001E+10 | 744.00 | 0.740858E+10 | 0.272709E+10 | 0.00 | 1.00 | 0.21 | 13298.13 | 12121.79 | 5532.09 | 2857.39 | 0.00 |
Report: DXReportMonthly
For: SPLIT MS1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.194297E+10 | 0.498792E+09 | 479.92 | 0.187660E+10 | 66373019.15 | 0.00 | 1.00 | 02-JAN-18:42 | 0.00 | 01-JAN-00:10 | 12668.73 | 17-JAN-20:33 | 12311.95 | 13-JAN-12:52 | 2146.50 | 17-JAN-20:33 | 2784.25 | 17-JAN-20:33 | 0.00 |
| February | 0.284956E+10 | 0.725170E+09 | 413.97 | 0.272010E+10 | 0.129462E+09 | 0.00 | 1.00 | 01-FEB-13:12 | 0.00 | 01-FEB-10:30 | 12890.97 | 25-FEB-19:22 | 12307.69 | 27-FEB-21:02 | 2948.87 | 25-FEB-19:23 | 2818.67 | 22-FEB-12:02 | 0.00 |
| March | 0.515628E+10 | 0.136254E+10 | 531.46 | 0.485640E+10 | 0.299885E+09 | 0.00 | 1.00 | 01-MAR-11:52 | 0.00 | 01-MAR-09:00 | 12966.53 | 18-MAR-11:12 | 12295.60 | 22-MAR-20:02 | 3160.07 | 18-MAR-11:13 | 2877.04 | 28-MAR-09:12 | 0.00 |
| April | 0.709253E+10 | 0.201683E+10 | 663.14 | 0.666593E+10 | 0.426593E+09 | 0.00 | 1.00 | 01-APR-07:52 | 0.00 | 01-APR-05:15 | 12965.57 | 24-APR-07:42 | 12257.27 | 09-APR-21:52 | 3558.99 | 24-APR-07:43 | 2872.70 | 24-APR-07:42 | 0.00 |
| May | 0.869161E+10 | 0.256159E+10 | 741.28 | 0.760638E+10 | 0.108523E+10 | 0.00 | 1.00 | 13-MAY-07:52 | 0.00 | 13-MAY-05:15 | 13152.04 | 13-MAY-07:52 | 9105.36 | 13-MAY-07:52 | 4223.30 | 13-MAY-07:53 | 2823.97 | 13-MAY-07:52 | 0.00 |
| June | 0.907309E+10 | 0.266380E+10 | 717.41 | 0.735610E+10 | 0.171699E+10 | 0.00 | 1.00 | 18-JUN-06:52 | 0.00 | 18-JUN-05:13 | 13206.20 | 18-JUN-06:52 | 9294.81 | 27-JUN-11:52 | 4523.94 | 18-JUN-06:53 | 2832.94 | 18-JUN-06:52 | 0.00 |
| July | 0.993222E+10 | 0.278448E+10 | 744.00 | 0.727652E+10 | 0.265571E+10 | 0.00 | 0.50 | 01-JUL-16:13 | 0.19 | 19-JUL-03:00 | 5425.14 | 01-JUL-16:13 | 4217.11 | 02-JUL-16:40 | 1402.54 | 01-JUL-16:01 | 1624.77 | 01-JUL-16:01 | 0.00 |
| August | 0.958009E+10 | 0.260977E+10 | 744.00 | 0.684527E+10 | 0.273482E+10 | 0.00 | 0.48 | 27-AUG-16:02 | 0.21 | 24-AUG-04:00 | 5293.50 | 27-AUG-16:02 | 3940.97 | 06-AUG-16:17 | 1560.62 | 12-AUG-10:00 | 1525.08 | 27-AUG-16:02 | 0.00 |
| September | 0.867976E+10 | 0.233868E+10 | 716.72 | 0.652856E+10 | 0.215120E+10 | 0.00 | 1.00 | 27-SEP-07:12 | 0.00 | 27-SEP-05:13 | 12994.99 | 27-SEP-07:12 | 9817.03 | 29-SEP-06:22 | 3611.62 | 27-SEP-07:13 | 2851.70 | 27-SEP-07:12 | 0.00 |
| October | 0.708721E+10 | 0.189569E+10 | 601.72 | 0.632455E+10 | 0.762655E+09 | 0.00 | 1.00 | 01-OCT-07:52 | 0.00 | 01-OCT-05:13 | 13456.11 | 13-OCT-09:12 | 12291.93 | 24-OCT-20:52 | 5380.48 | 13-OCT-09:13 | 2875.94 | 02-OCT-07:32 | 0.00 |
| November | 0.477502E+10 | 0.123443E+10 | 495.77 | 0.451848E+10 | 0.256545E+09 | 0.00 | 1.00 | 01-NOV-10:02 | 0.00 | 01-NOV-05:13 | 12790.28 | 09-NOV-09:32 | 12312.01 | 29-NOV-10:52 | 2387.56 | 09-NOV-09:33 | 2875.65 | 09-NOV-10:32 | 0.00 |
| December | 0.266735E+10 | 0.681587E+09 | 489.66 | 0.258206E+10 | 85292843.05 | 0.00 | 1.00 | 01-DEC-11:02 | 0.00 | 01-DEC-08:45 | 12784.56 | 29-DEC-22:52 | 12308.32 | 09-DEC-19:12 | 2851.50 | 29-DEC-22:52 | 2788.13 | 29-DEC-22:52 | 0.00 |
| Annual Sum or Average | 0.775277E+11 | 0.213733E+11 | 7339.05 | 0.651569E+11 | 0.123708E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.194297E+10 | 0.498792E+09 | 413.97 | 0.187660E+10 | 66373019.15 | 0.00 | 0.48 | 0.00 | 5293.50 | 3940.97 | 1402.54 | 1525.08 | 0.00 | ||||||
| Maximum of Months | 0.993222E+10 | 0.278448E+10 | 744.00 | 0.760638E+10 | 0.273482E+10 | 0.00 | 1.00 | 0.21 | 13456.11 | 12312.01 | 5380.48 | 2877.04 | 0.00 |
Report: DXReportMonthly
For: SPLIT MS2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.194581E+10 | 0.499503E+09 | 480.13 | 0.187937E+10 | 66441834.92 | 0.00 | 1.00 | 02-JAN-18:42 | 0.00 | 01-JAN-00:10 | 12659.94 | 17-JAN-20:33 | 12303.17 | 13-JAN-12:52 | 2144.55 | 17-JAN-20:33 | 2782.29 | 17-JAN-20:33 | 0.00 |
| February | 0.285732E+10 | 0.727075E+09 | 414.07 | 0.272763E+10 | 0.129686E+09 | 0.00 | 1.00 | 01-FEB-13:12 | 0.00 | 01-FEB-10:30 | 12880.26 | 25-FEB-19:22 | 12298.47 | 27-FEB-21:02 | 2940.85 | 25-FEB-19:23 | 2816.66 | 22-FEB-12:02 | 0.00 |
| March | 0.516525E+10 | 0.136478E+10 | 531.79 | 0.486509E+10 | 0.300158E+09 | 0.00 | 1.00 | 01-MAR-11:52 | 0.00 | 01-MAR-09:00 | 12957.08 | 18-MAR-11:12 | 12286.33 | 22-MAR-20:02 | 3156.93 | 18-MAR-11:13 | 2875.08 | 28-MAR-09:12 | 0.00 |
| April | 0.709664E+10 | 0.201789E+10 | 663.36 | 0.666982E+10 | 0.426825E+09 | 0.00 | 1.00 | 01-APR-07:52 | 0.00 | 01-APR-05:15 | 12956.60 | 24-APR-07:42 | 12248.31 | 09-APR-21:52 | 3554.91 | 24-APR-07:43 | 2870.67 | 24-APR-07:42 | 0.00 |
| May | 0.869421E+10 | 0.256232E+10 | 741.28 | 0.760884E+10 | 0.108538E+10 | 0.00 | 1.00 | 13-MAY-07:52 | 0.00 | 13-MAY-05:15 | 13142.75 | 13-MAY-07:52 | 9098.26 | 13-MAY-07:52 | 4220.79 | 13-MAY-07:53 | 2821.96 | 13-MAY-07:52 | 0.00 |
| June | 0.906987E+10 | 0.266282E+10 | 717.41 | 0.735302E+10 | 0.171685E+10 | 0.00 | 1.00 | 18-JUN-06:52 | 0.00 | 18-JUN-05:13 | 13197.04 | 18-JUN-06:52 | 9287.05 | 27-JUN-11:52 | 4523.21 | 18-JUN-06:53 | 2830.93 | 18-JUN-06:52 | 0.00 |
| July | 0.993277E+10 | 0.278456E+10 | 744.00 | 0.727698E+10 | 0.265579E+10 | 0.00 | 0.50 | 01-JUL-16:13 | 0.19 | 19-JUL-03:00 | 5421.49 | 01-JUL-16:13 | 4208.20 | 02-JUL-16:40 | 1401.17 | 01-JUL-16:01 | 1623.91 | 01-JUL-16:01 | 0.00 |
| August | 0.958080E+10 | 0.260988E+10 | 744.00 | 0.684588E+10 | 0.273492E+10 | 0.00 | 0.48 | 27-AUG-16:02 | 0.21 | 24-AUG-04:00 | 5290.39 | 27-AUG-16:02 | 3936.38 | 06-AUG-16:02 | 1560.97 | 12-AUG-10:00 | 1524.18 | 27-AUG-16:02 | 0.00 |
| September | 0.867906E+10 | 0.233843E+10 | 716.72 | 0.652789E+10 | 0.215117E+10 | 0.00 | 1.00 | 27-SEP-07:12 | 0.00 | 27-SEP-05:13 | 12985.96 | 27-SEP-07:12 | 9808.52 | 29-SEP-06:22 | 3610.73 | 27-SEP-07:13 | 2849.68 | 27-SEP-07:12 | 0.00 |
| October | 0.709141E+10 | 0.189671E+10 | 601.83 | 0.632847E+10 | 0.762939E+09 | 0.00 | 1.00 | 01-OCT-07:52 | 0.00 | 01-OCT-05:13 | 13446.76 | 13-OCT-09:12 | 12282.78 | 24-OCT-20:52 | 5375.68 | 13-OCT-09:13 | 2873.91 | 02-OCT-07:32 | 0.00 |
| November | 0.478016E+10 | 0.123566E+10 | 495.80 | 0.452347E+10 | 0.256687E+09 | 0.00 | 1.00 | 01-NOV-10:02 | 0.00 | 01-NOV-05:13 | 12780.97 | 09-NOV-09:32 | 12302.51 | 29-NOV-10:52 | 2385.04 | 09-NOV-09:33 | 2873.59 | 09-NOV-10:32 | 0.00 |
| December | 0.267080E+10 | 0.682438E+09 | 489.60 | 0.258542E+10 | 85380215.06 | 0.00 | 1.00 | 01-DEC-11:02 | 0.00 | 01-DEC-08:45 | 12775.40 | 29-DEC-22:52 | 12299.57 | 09-DEC-19:12 | 2850.26 | 29-DEC-22:52 | 2786.15 | 29-DEC-22:52 | 0.00 |
| Annual Sum or Average | 0.775641E+11 | 0.213821E+11 | 7339.99 | 0.651919E+11 | 0.123722E+11 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.194581E+10 | 0.499503E+09 | 414.07 | 0.187937E+10 | 66441834.92 | 0.00 | 0.48 | 0.00 | 5290.39 | 3936.38 | 1401.17 | 1524.18 | 0.00 | ||||||
| Maximum of Months | 0.993277E+10 | 0.278456E+10 | 744.00 | 0.760884E+10 | 0.273492E+10 | 0.00 | 1.00 | 0.21 | 13446.76 | 12303.17 | 5375.68 | 2875.08 | 0.00 |
Report: DXReportMonthly
For: SPLIT TSW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.253013E+09 | 62133219.50 | 71.70 | 0.250861E+09 | 2152032.27 | 0.00 | 1.00 | 03-JAN-14:22 | 0.00 | 01-JAN-00:10 | 8072.12 | 14-JAN-19:32 | 8014.62 | 12-JAN-16:22 | 739.87 | 14-JAN-22:52 | 1799.52 | 14-JAN-19:32 | 0.00 |
| February | 0.888451E+09 | 0.223692E+09 | 162.61 | 0.865787E+09 | 22664186.60 | 0.00 | 1.00 | 01-FEB-14:52 | 0.00 | 01-FEB-00:10 | 8382.21 | 25-FEB-15:12 | 8177.03 | 15-FEB-15:32 | 1695.88 | 25-FEB-19:22 | 1831.18 | 22-FEB-12:02 | 0.00 |
| March | 0.273736E+10 | 0.730420E+09 | 456.44 | 0.261305E+10 | 0.124310E+09 | 0.00 | 1.00 | 01-MAR-11:52 | 0.00 | 01-MAR-01:10 | 8413.85 | 18-MAR-11:12 | 8016.51 | 01-MAR-13:52 | 1914.68 | 18-MAR-11:12 | 1867.96 | 28-MAR-09:12 | 0.00 |
| April | 0.476978E+10 | 0.136570E+10 | 661.14 | 0.455022E+10 | 0.219559E+09 | 0.00 | 1.00 | 01-APR-07:52 | 0.00 | 01-APR-05:15 | 8439.61 | 24-APR-07:42 | 7962.21 | 09-APR-21:52 | 2410.28 | 24-APR-07:42 | 1864.95 | 24-APR-07:42 | 0.00 |
| May | 0.621711E+10 | 0.184065E+10 | 741.44 | 0.560826E+10 | 0.608849E+09 | 0.00 | 1.00 | 13-MAY-07:52 | 0.00 | 13-MAY-05:15 | 8576.62 | 13-MAY-07:52 | 5876.76 | 13-MAY-07:52 | 2699.86 | 13-MAY-07:52 | 1832.51 | 13-MAY-07:52 | 0.00 |
| June | 0.643787E+10 | 0.190000E+10 | 717.36 | 0.548178E+10 | 0.956086E+09 | 0.00 | 1.00 | 18-JUN-06:52 | 0.00 | 18-JUN-05:13 | 8636.78 | 18-JUN-06:52 | 6026.79 | 27-JUN-11:52 | 3127.65 | 18-JUN-06:52 | 1837.93 | 18-JUN-06:52 | 0.00 |
| July | 0.664511E+10 | 0.187398E+10 | 744.00 | 0.513316E+10 | 0.151195E+10 | 0.00 | 0.69 | 02-JUL-16:30 | 0.12 | 19-JUL-03:20 | 4629.93 | 02-JUL-16:30 | 4142.68 | 02-JUL-16:30 | 847.43 | 01-JUL-16:01 | 1433.38 | 02-JUL-16:30 | 0.00 |
| August | 0.616608E+10 | 0.169293E+10 | 744.00 | 0.464371E+10 | 0.152237E+10 | 0.00 | 0.61 | 06-AUG-16:13 | 0.14 | 24-AUG-04:00 | 4275.00 | 13-AUG-16:02 | 3661.59 | 06-AUG-16:13 | 974.80 | 12-AUG-10:00 | 1239.72 | 06-AUG-16:02 | 0.00 |
| September | 0.533003E+10 | 0.144953E+10 | 716.58 | 0.417207E+10 | 0.115796E+10 | 0.00 | 1.00 | 27-SEP-07:12 | 0.00 | 27-SEP-05:13 | 8476.44 | 27-SEP-07:12 | 6044.01 | 29-SEP-06:22 | 2532.15 | 27-SEP-07:12 | 1851.43 | 27-SEP-07:12 | 0.00 |
| October | 0.396747E+10 | 0.107507E+10 | 582.64 | 0.360996E+10 | 0.357511E+09 | 0.00 | 1.00 | 01-OCT-07:52 | 0.00 | 01-OCT-05:13 | 8762.89 | 13-OCT-09:12 | 7972.55 | 24-OCT-20:52 | 3660.08 | 13-OCT-09:12 | 1868.03 | 02-OCT-07:32 | 0.00 |
| November | 0.200665E+10 | 0.522948E+09 | 302.23 | 0.193507E+10 | 71579253.20 | 0.00 | 1.00 | 01-NOV-10:02 | 0.00 | 01-NOV-02:30 | 8337.47 | 09-NOV-09:32 | 8130.40 | 28-NOV-14:12 | 1677.82 | 09-NOV-09:32 | 1868.45 | 09-NOV-10:32 | 0.00 |
| December | 0.462447E+09 | 0.114585E+09 | 119.78 | 0.456364E+09 | 6083641.48 | 0.00 | 1.00 | 01-DEC-11:02 | 0.00 | 01-DEC-00:10 | 8134.55 | 10-DEC-17:22 | 8097.21 | 27-DEC-16:12 | 1015.07 | 10-DEC-19:22 | 1802.96 | 10-DEC-17:22 | 0.00 |
| Annual Sum or Average | 0.458814E+11 | 0.128516E+11 | 6019.92 | 0.393203E+11 | 0.656107E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.253013E+09 | 62133219.50 | 71.70 | 0.250861E+09 | 2152032.27 | 0.00 | 0.61 | 0.00 | 4275.00 | 3661.59 | 739.87 | 1239.72 | 0.00 | ||||||
| Maximum of Months | 0.664511E+10 | 0.190000E+10 | 744.00 | 0.560826E+10 | 0.152237E+10 | 0.00 | 1.00 | 0.14 | 8762.89 | 8177.03 | 3660.08 | 1868.45 | 0.00 |
Report: DXReportMonthly
For: SPLIT TNW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 1391951.23 | 355477.55 | 1.76 | 1294431.85 | 97519.38 | 0.00 | 0.53 | 14-JAN-22:52 | 0.00 | 01-JAN-00:10 | 3927.11 | 14-JAN-22:52 | 3497.14 | 14-JAN-22:52 | 429.97 | 14-JAN-22:52 | 951.93 | 14-JAN-22:52 | 0.00 |
| February | 0.305120E+09 | 79127678.64 | 85.02 | 0.293444E+09 | 11675620.86 | 0.00 | 1.00 | 08-FEB-13:42 | 0.00 | 01-FEB-00:10 | 8422.49 | 25-FEB-16:42 | 7955.38 | 22-FEB-20:32 | 2052.97 | 25-FEB-22:52 | 1830.44 | 22-FEB-12:02 | 0.00 |
| March | 0.197072E+10 | 0.532725E+09 | 417.06 | 0.186312E+10 | 0.107596E+09 | 0.00 | 1.00 | 01-MAR-14:22 | 0.00 | 01-MAR-00:10 | 8382.18 | 18-MAR-11:52 | 7978.53 | 22-MAR-20:12 | 1819.63 | 29-MAR-09:22 | 1882.92 | 10-MAR-10:12 | 0.00 |
| April | 0.424257E+10 | 0.122169E+10 | 657.67 | 0.402870E+10 | 0.213862E+09 | 0.00 | 1.00 | 01-APR-07:52 | 0.00 | 01-APR-05:15 | 8445.44 | 24-APR-07:42 | 7934.86 | 09-APR-21:12 | 2438.72 | 24-APR-07:42 | 1864.61 | 24-APR-07:42 | 0.00 |
| May | 0.611249E+10 | 0.181046E+10 | 741.44 | 0.550134E+10 | 0.611146E+09 | 0.00 | 1.00 | 13-MAY-07:52 | 0.00 | 13-MAY-05:15 | 8559.40 | 13-MAY-07:52 | 5926.18 | 13-MAY-07:52 | 2633.22 | 13-MAY-07:52 | 1832.04 | 13-MAY-07:52 | 0.00 |
| June | 0.645844E+10 | 0.190554E+10 | 717.36 | 0.549797E+10 | 0.960467E+09 | 0.00 | 1.00 | 18-JUN-06:52 | 0.00 | 18-JUN-05:13 | 8625.54 | 18-JUN-06:52 | 6000.61 | 27-JUN-11:52 | 3093.37 | 18-JUN-06:52 | 1837.50 | 18-JUN-06:52 | 0.00 |
| July | 0.663962E+10 | 0.187240E+10 | 744.00 | 0.512766E+10 | 0.151196E+10 | 0.00 | 0.68 | 02-JUL-16:50 | 0.12 | 19-JUL-03:30 | 4539.41 | 02-JUL-16:50 | 4079.89 | 02-JUL-16:50 | 844.27 | 19-JUL-11:50 | 1407.64 | 02-JUL-16:50 | 0.00 |
| August | 0.606087E+10 | 0.166450E+10 | 744.00 | 0.453950E+10 | 0.152137E+10 | 0.00 | 0.59 | 07-AUG-16:20 | 0.14 | 24-AUG-04:00 | 4080.39 | 07-AUG-16:20 | 3514.86 | 07-AUG-16:20 | 919.27 | 12-AUG-10:00 | 1210.23 | 07-AUG-16:20 | 0.00 |
| September | 0.487058E+10 | 0.132656E+10 | 716.58 | 0.373175E+10 | 0.113884E+10 | 0.00 | 1.00 | 27-SEP-07:12 | 0.00 | 27-SEP-05:13 | 8481.44 | 27-SEP-07:12 | 5974.70 | 29-SEP-06:22 | 2607.17 | 27-SEP-07:12 | 1851.00 | 27-SEP-07:12 | 0.00 |
| October | 0.287584E+10 | 0.787722E+09 | 554.81 | 0.255386E+10 | 0.321980E+09 | 0.00 | 1.00 | 01-OCT-08:22 | 0.00 | 01-OCT-05:13 | 8780.19 | 13-OCT-09:32 | 7808.92 | 24-OCT-21:42 | 3741.57 | 13-OCT-09:32 | 1881.23 | 09-OCT-09:22 | 0.00 |
| November | 0.862548E+09 | 0.231616E+09 | 210.06 | 0.818390E+09 | 44157901.08 | 0.00 | 1.00 | 01-NOV-11:02 | 0.00 | 01-NOV-01:30 | 8291.39 | 09-NOV-10:32 | 7966.70 | 01-NOV-20:22 | 1769.94 | 09-NOV-10:32 | 1870.27 | 06-NOV-11:12 | 0.00 |
| December | 17877904.28 | 4582048.70 | 8.27 | 17654598.77 | 223305.50 | 0.00 | 1.00 | 01-DEC-15:41 | 0.00 | 01-DEC-00:10 | 7846.39 | 01-DEC-20:12 | 7846.39 | 01-DEC-20:12 | 417.47 | 16-DEC-20:42 | 1782.08 | 01-DEC-20:12 | 0.00 |
| Annual Sum or Average | 0.404181E+11 | 0.114373E+11 | 5598.04 | 0.339747E+11 | 0.644337E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 1391951.23 | 355477.55 | 1.76 | 1294431.85 | 97519.38 | 0.00 | 0.53 | 0.00 | 3927.11 | 3497.14 | 417.47 | 951.93 | 0.00 | ||||||
| Maximum of Months | 0.663962E+10 | 0.190554E+10 | 744.00 | 0.550134E+10 | 0.152137E+10 | 0.00 | 1.00 | 0.14 | 8780.19 | 7978.53 | 3741.57 | 1882.92 | 0.00 |
Report: DXReportMonthly
For: SPLIT TSE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.228275E+09 | 55881625.54 | 67.18 | 0.226427E+09 | 1848850.08 | 0.00 | 1.00 | 03-JAN-14:22 | 0.00 | 01-JAN-00:10 | 7690.75 | 14-JAN-19:32 | 7616.08 | 12-JAN-15:12 | 707.85 | 14-JAN-22:52 | 1713.53 | 14-JAN-19:32 | 0.00 |
| February | 0.885312E+09 | 0.222250E+09 | 164.67 | 0.862751E+09 | 22561378.17 | 0.00 | 1.00 | 01-FEB-13:12 | 0.00 | 01-FEB-00:10 | 7970.17 | 25-FEB-15:12 | 7783.46 | 15-FEB-15:32 | 1707.97 | 25-FEB-19:22 | 1744.29 | 22-FEB-12:02 | 0.00 |
| March | 0.273399E+10 | 0.726836E+09 | 458.60 | 0.260739E+10 | 0.126598E+09 | 0.00 | 1.00 | 01-MAR-11:52 | 0.00 | 01-MAR-01:10 | 8003.95 | 18-MAR-11:12 | 7740.88 | 16-MAR-12:02 | 1787.56 | 18-MAR-11:12 | 1778.79 | 28-MAR-09:12 | 0.00 |
| April | 0.479084E+10 | 0.136631E+10 | 664.86 | 0.456736E+10 | 0.223480E+09 | 0.00 | 1.00 | 01-APR-07:52 | 0.00 | 01-APR-05:15 | 8058.19 | 24-APR-07:42 | 7575.18 | 09-APR-21:52 | 2204.79 | 24-APR-07:42 | 1776.02 | 24-APR-07:42 | 0.00 |
| May | 0.624985E+10 | 0.184345E+10 | 741.44 | 0.563863E+10 | 0.611222E+09 | 0.00 | 1.00 | 13-MAY-07:52 | 0.00 | 13-MAY-05:15 | 8166.36 | 13-MAY-07:52 | 5595.71 | 13-MAY-07:52 | 2700.53 | 13-MAY-07:53 | 1744.68 | 13-MAY-07:53 | 0.00 |
| June | 0.637407E+10 | 0.187546E+10 | 717.36 | 0.541899E+10 | 0.955078E+09 | 0.00 | 1.00 | 18-JUN-06:52 | 0.00 | 18-JUN-05:13 | 8225.84 | 18-JUN-06:52 | 5739.58 | 27-JUN-11:52 | 2997.49 | 18-JUN-06:52 | 1749.70 | 18-JUN-06:52 | 0.00 |
| July | 0.664691E+10 | 0.186893E+10 | 744.00 | 0.513480E+10 | 0.151210E+10 | 0.00 | 0.63 | 02-JUL-16:10 | 0.12 | 19-JUL-03:20 | 4155.44 | 01-JUL-16:10 | 3548.45 | 02-JUL-16:01 | 835.57 | 19-JUL-11:00 | 1252.95 | 02-JUL-16:10 | 0.00 |
| August | 0.616989E+10 | 0.168919E+10 | 744.00 | 0.464728E+10 | 0.152261E+10 | 0.00 | 0.58 | 07-AUG-15:10 | 0.14 | 24-AUG-04:00 | 3916.88 | 27-AUG-16:10 | 3311.78 | 07-AUG-15:10 | 983.49 | 12-AUG-10:00 | 1139.60 | 07-AUG-15:10 | 0.00 |
| September | 0.531288E+10 | 0.144091E+10 | 716.58 | 0.415463E+10 | 0.115824E+10 | 0.00 | 1.00 | 27-SEP-07:12 | 0.00 | 27-SEP-05:13 | 8080.01 | 27-SEP-07:12 | 5735.03 | 29-SEP-06:22 | 2405.28 | 27-SEP-07:12 | 1762.75 | 27-SEP-07:12 | 0.00 |
| October | 0.399050E+10 | 0.107734E+10 | 585.89 | 0.362834E+10 | 0.362160E+09 | 0.00 | 1.00 | 01-OCT-07:52 | 0.00 | 01-OCT-05:13 | 8353.22 | 13-OCT-09:12 | 7591.17 | 24-OCT-20:52 | 3474.73 | 13-OCT-09:13 | 1779.19 | 02-OCT-07:32 | 0.00 |
| November | 0.199215E+10 | 0.517388E+09 | 303.56 | 0.191922E+10 | 72924652.53 | 0.00 | 1.00 | 01-NOV-10:02 | 0.00 | 01-NOV-02:20 | 7945.74 | 09-NOV-09:32 | 7733.80 | 28-NOV-14:12 | 1521.02 | 09-NOV-09:32 | 1777.75 | 09-NOV-10:32 | 0.00 |
| December | 0.438957E+09 | 0.108415E+09 | 113.98 | 0.433441E+09 | 5515292.03 | 0.00 | 1.00 | 01-DEC-11:02 | 0.00 | 01-DEC-00:10 | 7705.18 | 27-DEC-15:02 | 7705.18 | 27-DEC-15:02 | 942.61 | 10-DEC-17:22 | 1714.17 | 17-DEC-20:02 | 0.00 |
| Annual Sum or Average | 0.458136E+11 | 0.127923E+11 | 6022.12 | 0.392393E+11 | 0.657435E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.228275E+09 | 55881625.54 | 67.18 | 0.226427E+09 | 1848850.08 | 0.00 | 0.58 | 0.00 | 3916.88 | 3311.78 | 707.85 | 1139.60 | 0.00 | ||||||
| Maximum of Months | 0.664691E+10 | 0.187546E+10 | 744.00 | 0.563863E+10 | 0.152261E+10 | 0.00 | 1.00 | 0.14 | 8353.22 | 7783.46 | 3474.73 | 1779.19 | 0.00 |
Report: DXReportMonthly
For: SPLIT TNE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 735938.90 | 188969.99 | 1.14 | 694378.46 | 41560.44 | 0.00 | 0.36 | 26-JAN-20:42 | 0.00 | 01-JAN-00:10 | 2386.11 | 14-JAN-22:52 | 2365.11 | 26-JAN-20:42 | 262.61 | 14-JAN-22:52 | 601.95 | 26-JAN-20:42 | 0.00 |
| February | 0.292149E+09 | 75762064.08 | 84.92 | 0.280980E+09 | 11168192.10 | 0.00 | 1.00 | 07-FEB-13:22 | 0.00 | 01-FEB-00:10 | 7978.57 | 25-FEB-22:52 | 7571.89 | 22-FEB-20:32 | 2005.33 | 25-FEB-22:52 | 1743.99 | 22-FEB-12:02 | 0.00 |
| March | 0.195161E+10 | 0.526617E+09 | 417.45 | 0.184205E+10 | 0.109560E+09 | 0.00 | 1.00 | 01-MAR-14:22 | 0.00 | 01-MAR-00:10 | 7970.00 | 18-MAR-11:52 | 7586.85 | 21-MAR-19:42 | 1667.94 | 29-MAR-09:22 | 1792.18 | 10-MAR-10:12 | 0.00 |
| April | 0.426229E+10 | 0.122285E+10 | 661.22 | 0.404400E+10 | 0.218293E+09 | 0.00 | 1.00 | 01-APR-07:52 | 0.00 | 01-APR-05:15 | 8061.18 | 24-APR-07:42 | 7551.94 | 09-APR-21:12 | 2233.21 | 24-APR-07:42 | 1775.04 | 24-APR-07:42 | 0.00 |
| May | 0.614571E+10 | 0.181348E+10 | 741.44 | 0.553227E+10 | 0.613434E+09 | 0.00 | 1.00 | 13-MAY-07:52 | 0.00 | 13-MAY-05:15 | 8146.19 | 13-MAY-07:52 | 5643.55 | 13-MAY-07:52 | 2635.46 | 13-MAY-07:53 | 1743.51 | 13-MAY-07:52 | 0.00 |
| June | 0.639488E+10 | 0.188096E+10 | 717.36 | 0.543548E+10 | 0.959400E+09 | 0.00 | 1.00 | 18-JUN-06:52 | 0.00 | 18-JUN-05:13 | 8212.25 | 18-JUN-06:52 | 5712.60 | 27-JUN-11:52 | 2964.21 | 18-JUN-06:52 | 1748.66 | 18-JUN-06:52 | 0.00 |
| July | 0.664167E+10 | 0.186737E+10 | 744.00 | 0.512959E+10 | 0.151208E+10 | 0.00 | 0.62 | 02-JUL-17:10 | 0.12 | 19-JUL-03:30 | 4016.96 | 01-JUL-16:20 | 3521.78 | 07-JUL-16:10 | 845.30 | 19-JUL-11:00 | 1221.45 | 02-JUL-17:10 | 0.00 |
| August | 0.606503E+10 | 0.166098E+10 | 744.00 | 0.454336E+10 | 0.152167E+10 | 0.00 | 0.57 | 07-AUG-16:10 | 0.14 | 24-AUG-04:00 | 3708.12 | 07-AUG-16:10 | 3167.42 | 07-AUG-16:10 | 931.35 | 12-AUG-10:10 | 1105.09 | 07-AUG-16:10 | 0.00 |
| September | 0.485432E+10 | 0.131881E+10 | 716.58 | 0.371468E+10 | 0.113964E+10 | 0.00 | 1.00 | 27-SEP-07:12 | 0.00 | 27-SEP-05:13 | 8082.41 | 27-SEP-07:12 | 5665.14 | 29-SEP-06:22 | 2478.73 | 27-SEP-07:12 | 1761.70 | 27-SEP-07:12 | 0.00 |
| October | 0.289069E+10 | 0.789665E+09 | 560.42 | 0.256357E+10 | 0.327125E+09 | 0.00 | 1.00 | 01-OCT-08:22 | 0.00 | 01-OCT-05:13 | 8361.47 | 13-OCT-09:32 | 7441.06 | 24-OCT-21:42 | 3539.51 | 13-OCT-09:33 | 1790.90 | 09-OCT-09:22 | 0.00 |
| November | 0.831706E+09 | 0.223250E+09 | 208.63 | 0.787463E+09 | 44243750.12 | 0.00 | 1.00 | 01-NOV-11:02 | 0.00 | 01-NOV-01:20 | 7902.16 | 09-NOV-10:32 | 7579.92 | 29-NOV-18:02 | 1540.78 | 09-NOV-10:32 | 1786.76 | 04-NOV-10:52 | 0.00 |
| December | 14023356.61 | 3576136.64 | 6.03 | 13930795.45 | 92561.16 | 0.00 | 1.00 | 01-DEC-15:41 | 0.00 | 01-DEC-00:10 | 7447.66 | 03-DEC-13:42 | 7447.66 | 03-DEC-13:42 | 248.57 | 28-DEC-22:52 | 1705.68 | 03-DEC-13:42 | 0.00 |
| Annual Sum or Average | 0.403448E+11 | 0.113835E+11 | 5603.19 | 0.338881E+11 | 0.645675E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 735938.90 | 188969.99 | 1.14 | 694378.46 | 41560.44 | 0.00 | 0.36 | 0.00 | 2386.11 | 2365.11 | 248.57 | 601.95 | 0.00 | ||||||
| Maximum of Months | 0.664167E+10 | 0.188096E+10 | 744.00 | 0.553227E+10 | 0.152167E+10 | 0.00 | 1.00 | 0.14 | 8361.47 | 7586.85 | 3539.51 | 1792.18 | 0.00 |
Report: DXReportMonthly
For: SPLIT TN1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 3910659.51 | 997958.52 | 5.12 | 3619919.58 | 290739.93 | 0.00 | 0.87 | 14-JAN-22:52 | 0.00 | 01-JAN-00:10 | 5869.65 | 14-JAN-22:52 | 5282.95 | 14-JAN-22:52 | 586.69 | 14-JAN-22:52 | 1341.95 | 14-JAN-22:52 | 0.00 |
| February | 0.266793E+09 | 68982676.30 | 108.43 | 0.252247E+09 | 14546130.80 | 0.00 | 1.00 | 08-FEB-13:42 | 0.00 | 01-FEB-00:10 | 7205.90 | 25-FEB-22:52 | 6801.72 | 22-FEB-20:32 | 1763.35 | 25-FEB-22:52 | 1565.49 | 22-FEB-12:02 | 0.00 |
| March | 0.163465E+10 | 0.441077E+09 | 447.96 | 0.152803E+10 | 0.106617E+09 | 0.00 | 1.00 | 01-MAR-14:22 | 0.00 | 01-MAR-01:10 | 7163.74 | 18-MAR-11:52 | 6813.38 | 21-MAR-19:42 | 1640.94 | 29-MAR-09:23 | 1609.28 | 10-MAR-10:12 | 0.00 |
| April | 0.338201E+10 | 0.974029E+09 | 658.72 | 0.317966E+10 | 0.202356E+09 | 0.00 | 1.00 | 01-APR-07:52 | 0.00 | 01-APR-05:15 | 7223.58 | 24-APR-07:42 | 6785.49 | 09-APR-21:12 | 2068.09 | 24-APR-07:42 | 1593.95 | 24-APR-07:42 | 0.00 |
| May | 0.493287E+10 | 0.146093E+10 | 741.44 | 0.436943E+10 | 0.563437E+09 | 0.00 | 1.00 | 13-MAY-07:52 | 0.00 | 13-MAY-05:15 | 7310.34 | 13-MAY-07:52 | 5089.99 | 13-MAY-07:52 | 2330.72 | 13-MAY-07:53 | 1566.03 | 13-MAY-07:52 | 0.00 |
| June | 0.529341E+10 | 0.155991E+10 | 717.36 | 0.439791E+10 | 0.895500E+09 | 0.00 | 1.00 | 18-JUN-06:52 | 0.00 | 18-JUN-05:13 | 7361.41 | 18-JUN-06:52 | 5081.10 | 27-JUN-11:52 | 2644.64 | 18-JUN-06:53 | 1571.04 | 18-JUN-06:53 | 0.00 |
| July | 0.561841E+10 | 0.158048E+10 | 744.00 | 0.422956E+10 | 0.138886E+10 | 0.00 | 0.57 | 02-JUL-17:20 | 0.14 | 19-JUL-03:30 | 3316.88 | 01-JUL-16:30 | 2825.79 | 02-JUL-17:20 | 719.26 | 01-JUL-16:13 | 1019.41 | 02-JUL-17:20 | 0.00 |
| August | 0.520824E+10 | 0.142498E+10 | 744.00 | 0.379350E+10 | 0.141474E+10 | 0.00 | 0.51 | 07-AUG-16:20 | 0.16 | 24-AUG-04:00 | 3064.62 | 27-AUG-16:02 | 2532.96 | 07-AUG-16:20 | 815.53 | 12-AUG-10:10 | 907.15 | 07-AUG-16:20 | 0.00 |
| September | 0.417956E+10 | 0.113304E+10 | 716.58 | 0.311041E+10 | 0.106915E+10 | 0.00 | 1.00 | 27-SEP-07:12 | 0.00 | 27-SEP-05:13 | 7257.07 | 27-SEP-07:12 | 5120.67 | 29-SEP-06:22 | 2225.62 | 27-SEP-07:12 | 1582.31 | 27-SEP-07:12 | 0.00 |
| October | 0.243479E+10 | 0.663918E+09 | 569.00 | 0.212157E+10 | 0.313224E+09 | 0.00 | 1.00 | 01-OCT-08:22 | 0.00 | 01-OCT-05:13 | 7504.25 | 13-OCT-09:32 | 6658.90 | 24-OCT-21:42 | 3211.56 | 13-OCT-09:33 | 1608.03 | 09-OCT-09:22 | 0.00 |
| November | 0.717289E+09 | 0.192033E+09 | 247.49 | 0.670605E+09 | 46684666.97 | 0.00 | 1.00 | 01-NOV-11:02 | 0.00 | 01-NOV-03:00 | 7098.13 | 08-NOV-22:52 | 6809.41 | 29-NOV-18:02 | 1435.98 | 09-NOV-10:32 | 1602.13 | 04-NOV-10:52 | 0.00 |
| December | 15953380.54 | 4062283.18 | 11.27 | 15486680.88 | 466699.67 | 0.00 | 1.00 | 01-DEC-15:41 | 0.00 | 01-DEC-00:10 | 6653.04 | 01-DEC-15:41 | 6653.04 | 01-DEC-15:41 | 439.71 | 16-DEC-20:42 | 1518.27 | 01-DEC-15:41 | 0.00 |
| Annual Sum or Average | 0.336879E+11 | 0.950443E+10 | 5711.39 | 0.276720E+11 | 0.601588E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 3910659.51 | 997958.52 | 5.12 | 3619919.58 | 290739.93 | 0.00 | 0.51 | 0.00 | 3064.62 | 2532.96 | 439.71 | 907.15 | 0.00 | ||||||
| Maximum of Months | 0.561841E+10 | 0.158048E+10 | 744.00 | 0.439791E+10 | 0.141474E+10 | 0.00 | 1.00 | 0.16 | 7504.25 | 6813.38 | 3211.56 | 1609.28 | 0.00 |
Report: DXReportMonthly
For: SPLIT TN2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 3797198.25 | 969620.31 | 5.15 | 3519811.66 | 277386.60 | 0.00 | 0.85 | 14-JAN-22:52 | 0.00 | 01-JAN-00:10 | 5698.68 | 14-JAN-22:52 | 5125.43 | 14-JAN-22:52 | 573.25 | 14-JAN-22:52 | 1307.68 | 14-JAN-22:52 | 0.00 |
| February | 0.269835E+09 | 69762646.51 | 108.41 | 0.255248E+09 | 14587325.70 | 0.00 | 1.00 | 08-FEB-13:42 | 0.00 | 01-FEB-00:10 | 7191.27 | 25-FEB-22:52 | 6788.99 | 22-FEB-20:32 | 1759.86 | 25-FEB-22:52 | 1562.90 | 22-FEB-12:02 | 0.00 |
| March | 0.164113E+10 | 0.442742E+09 | 448.11 | 0.153427E+10 | 0.106856E+09 | 0.00 | 1.00 | 01-MAR-14:22 | 0.00 | 01-MAR-01:10 | 7150.13 | 18-MAR-11:52 | 6800.79 | 21-MAR-19:42 | 1651.12 | 29-MAR-09:23 | 1606.39 | 10-MAR-10:12 | 0.00 |
| April | 0.338490E+10 | 0.974752E+09 | 658.97 | 0.318234E+10 | 0.202558E+09 | 0.00 | 1.00 | 01-APR-07:52 | 0.00 | 01-APR-05:15 | 7210.63 | 24-APR-07:42 | 6772.84 | 09-APR-21:12 | 2063.96 | 24-APR-07:42 | 1591.00 | 24-APR-07:42 | 0.00 |
| May | 0.493465E+10 | 0.146133E+10 | 741.44 | 0.437108E+10 | 0.563562E+09 | 0.00 | 1.00 | 13-MAY-07:52 | 0.00 | 13-MAY-05:15 | 7296.87 | 13-MAY-07:52 | 5079.80 | 13-MAY-07:52 | 2326.99 | 13-MAY-07:53 | 1563.12 | 13-MAY-07:52 | 0.00 |
| June | 0.529159E+10 | 0.155924E+10 | 717.36 | 0.439611E+10 | 0.895483E+09 | 0.00 | 1.00 | 18-JUN-06:52 | 0.00 | 18-JUN-05:13 | 7347.88 | 18-JUN-06:52 | 5071.26 | 27-JUN-11:52 | 2641.37 | 18-JUN-06:53 | 1568.12 | 18-JUN-06:53 | 0.00 |
| July | 0.561874E+10 | 0.158042E+10 | 744.00 | 0.422981E+10 | 0.138893E+10 | 0.00 | 0.57 | 02-JUL-17:20 | 0.14 | 19-JUL-03:30 | 3309.81 | 01-JUL-16:30 | 2811.72 | 02-JUL-17:20 | 717.94 | 01-JUL-16:13 | 1014.95 | 02-JUL-17:20 | 0.00 |
| August | 0.520869E+10 | 0.142497E+10 | 744.00 | 0.379386E+10 | 0.141482E+10 | 0.00 | 0.51 | 07-AUG-16:20 | 0.16 | 24-AUG-04:00 | 3060.50 | 27-AUG-16:02 | 2526.76 | 07-AUG-16:20 | 815.89 | 12-AUG-10:10 | 905.05 | 07-AUG-16:20 | 0.00 |
| September | 0.417933E+10 | 0.113290E+10 | 716.58 | 0.311014E+10 | 0.106919E+10 | 0.00 | 1.00 | 27-SEP-07:12 | 0.00 | 27-SEP-05:13 | 7243.88 | 27-SEP-07:12 | 5109.34 | 29-SEP-06:22 | 2223.66 | 27-SEP-07:12 | 1579.38 | 27-SEP-07:12 | 0.00 |
| October | 0.243841E+10 | 0.664858E+09 | 569.17 | 0.212492E+10 | 0.313488E+09 | 0.00 | 1.00 | 01-OCT-08:22 | 0.00 | 01-OCT-05:13 | 7490.76 | 13-OCT-09:32 | 6646.06 | 24-OCT-21:42 | 3203.47 | 13-OCT-09:33 | 1605.07 | 09-OCT-09:22 | 0.00 |
| November | 0.720588E+09 | 0.192907E+09 | 246.93 | 0.673875E+09 | 46713106.37 | 0.00 | 1.00 | 01-NOV-11:02 | 0.00 | 01-NOV-03:00 | 7084.71 | 08-NOV-22:52 | 6796.07 | 29-NOV-18:02 | 1424.81 | 09-NOV-10:32 | 1599.39 | 04-NOV-10:52 | 0.00 |
| December | 15917460.34 | 4051934.53 | 11.11 | 15471313.47 | 446146.87 | 0.00 | 1.00 | 01-DEC-15:41 | 0.00 | 01-DEC-00:10 | 6645.13 | 01-DEC-15:41 | 6645.13 | 01-DEC-15:41 | 428.71 | 16-DEC-20:42 | 1515.87 | 01-DEC-15:41 | 0.00 |
| Annual Sum or Average | 0.337076E+11 | 0.950890E+10 | 5711.24 | 0.276907E+11 | 0.601692E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 3797198.25 | 969620.31 | 5.15 | 3519811.66 | 277386.60 | 0.00 | 0.51 | 0.00 | 3060.50 | 2526.76 | 428.71 | 905.05 | 0.00 | ||||||
| Maximum of Months | 0.561874E+10 | 0.158042E+10 | 744.00 | 0.439611E+10 | 0.141482E+10 | 0.00 | 1.00 | 0.16 | 7490.76 | 6800.79 | 3203.47 | 1606.39 | 0.00 |
Report: DXReportMonthly
For: SPLIT TS1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.284671E+09 | 70441310.76 | 117.45 | 0.280205E+09 | 4465463.87 | 0.00 | 1.00 | 03-JAN-14:22 | 0.00 | 01-JAN-00:10 | 6923.29 | 14-JAN-22:52 | 6848.28 | 12-JAN-15:12 | 640.17 | 18-JAN-19:42 | 1541.65 | 14-JAN-22:52 | 0.00 |
| February | 0.888220E+09 | 0.223146E+09 | 214.33 | 0.860016E+09 | 28203987.72 | 0.00 | 1.00 | 01-FEB-13:12 | 0.00 | 01-FEB-00:10 | 7166.00 | 25-FEB-15:12 | 6987.22 | 15-FEB-15:32 | 1471.43 | 25-FEB-19:22 | 1568.20 | 22-FEB-12:02 | 0.00 |
| March | 0.242272E+10 | 0.644675E+09 | 499.04 | 0.229736E+10 | 0.125358E+09 | 0.00 | 1.00 | 01-MAR-11:52 | 0.00 | 01-MAR-02:40 | 7203.01 | 18-MAR-11:12 | 6913.38 | 16-MAR-13:12 | 1758.78 | 18-MAR-11:13 | 1599.82 | 28-MAR-09:12 | 0.00 |
| April | 0.391341E+10 | 0.112068E+10 | 661.61 | 0.370475E+10 | 0.208654E+09 | 0.00 | 1.00 | 01-APR-07:52 | 0.00 | 01-APR-05:15 | 7231.71 | 24-APR-07:42 | 6819.87 | 09-APR-21:52 | 2041.96 | 24-APR-07:42 | 1597.17 | 24-APR-07:42 | 0.00 |
| May | 0.503748E+10 | 0.149177E+10 | 741.44 | 0.447656E+10 | 0.560923E+09 | 0.00 | 1.00 | 13-MAY-07:52 | 0.00 | 13-MAY-05:15 | 7339.53 | 13-MAY-07:52 | 5055.91 | 13-MAY-07:52 | 2391.84 | 13-MAY-07:53 | 1569.36 | 13-MAY-07:53 | 0.00 |
| June | 0.527125E+10 | 0.155403E+10 | 717.36 | 0.438093E+10 | 0.890312E+09 | 0.00 | 1.00 | 18-JUN-06:52 | 0.00 | 18-JUN-05:13 | 7385.07 | 18-JUN-06:52 | 5111.83 | 27-JUN-11:52 | 2677.97 | 18-JUN-06:53 | 1574.36 | 18-JUN-06:53 | 0.00 |
| July | 0.562287E+10 | 0.158193E+10 | 744.00 | 0.423471E+10 | 0.138816E+10 | 0.00 | 0.58 | 02-JUL-16:20 | 0.14 | 19-JUL-03:20 | 3442.56 | 01-JUL-16:01 | 2880.78 | 02-JUL-16:20 | 747.43 | 01-JUL-16:01 | 1042.49 | 02-JUL-16:20 | 0.00 |
| August | 0.531436E+10 | 0.145393E+10 | 744.00 | 0.389798E+10 | 0.141638E+10 | 0.00 | 0.54 | 27-AUG-16:02 | 0.16 | 24-AUG-04:00 | 3313.70 | 27-AUG-16:02 | 2656.39 | 06-AUG-16:02 | 870.80 | 12-AUG-10:00 | 950.19 | 27-AUG-16:02 | 0.00 |
| September | 0.464622E+10 | 0.125872E+10 | 716.56 | 0.355439E+10 | 0.109183E+10 | 0.00 | 1.00 | 27-SEP-07:12 | 0.00 | 27-SEP-05:13 | 7265.01 | 27-SEP-07:12 | 5199.00 | 29-SEP-06:22 | 2153.63 | 27-SEP-07:12 | 1585.57 | 27-SEP-07:12 | 0.00 |
| October | 0.354476E+10 | 0.956434E+09 | 595.17 | 0.319241E+10 | 0.352351E+09 | 0.00 | 1.00 | 01-OCT-07:52 | 0.00 | 01-OCT-05:13 | 7503.55 | 13-OCT-09:12 | 6825.21 | 24-OCT-20:52 | 3129.02 | 13-OCT-09:13 | 1599.95 | 02-OCT-07:32 | 0.00 |
| November | 0.191944E+10 | 0.497667E+09 | 365.16 | 0.183920E+10 | 80242997.49 | 0.00 | 1.00 | 01-NOV-10:02 | 0.00 | 01-NOV-04:50 | 7137.70 | 09-NOV-09:32 | 6955.28 | 28-NOV-14:12 | 1426.75 | 18-NOV-10:33 | 1599.37 | 09-NOV-10:32 | 0.00 |
| December | 0.522537E+09 | 0.129775E+09 | 167.67 | 0.512832E+09 | 9705612.46 | 0.00 | 1.00 | 01-DEC-11:02 | 0.00 | 01-DEC-01:30 | 7000.21 | 10-DEC-19:22 | 6928.72 | 27-DEC-15:02 | 1067.43 | 10-DEC-19:22 | 1545.61 | 10-DEC-19:22 | 0.00 |
| Annual Sum or Average | 0.393879E+11 | 0.109832E+11 | 6283.78 | 0.332314E+11 | 0.615659E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.284671E+09 | 70441310.76 | 117.45 | 0.280205E+09 | 4465463.87 | 0.00 | 0.54 | 0.00 | 3313.70 | 2656.39 | 640.17 | 950.19 | 0.00 | ||||||
| Maximum of Months | 0.562287E+10 | 0.158193E+10 | 744.00 | 0.447656E+10 | 0.141638E+10 | 0.00 | 1.00 | 0.16 | 7503.55 | 6987.22 | 3129.02 | 1599.95 | 0.00 |
Report: DXReportMonthly
For: SPLIT TS2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
| January | 0.286517E+09 | 70873512.08 | 117.11 | 0.282068E+09 | 4449247.42 | 0.00 | 1.00 | 03-JAN-14:22 | 0.00 | 01-JAN-00:10 | 6910.25 | 14-JAN-22:52 | 6836.77 | 12-JAN-15:12 | 617.66 | 18-JAN-19:42 | 1538.80 | 14-JAN-22:52 | 0.00 |
| February | 0.893376E+09 | 0.224368E+09 | 215.21 | 0.865050E+09 | 28326413.08 | 0.00 | 1.00 | 01-FEB-13:12 | 0.00 | 01-FEB-00:10 | 7153.04 | 25-FEB-15:12 | 6975.13 | 15-FEB-15:32 | 1470.04 | 25-FEB-19:22 | 1565.52 | 22-FEB-12:02 | 0.00 |
| March | 0.242855E+10 | 0.646062E+09 | 499.38 | 0.230299E+10 | 0.125554E+09 | 0.00 | 1.00 | 01-MAR-11:52 | 0.00 | 01-MAR-02:40 | 7189.54 | 18-MAR-11:12 | 6902.72 | 16-MAR-13:12 | 1754.62 | 18-MAR-11:13 | 1597.01 | 28-MAR-09:12 | 0.00 |
| April | 0.391613E+10 | 0.112130E+10 | 661.65 | 0.370729E+10 | 0.208840E+09 | 0.00 | 1.00 | 01-APR-07:52 | 0.00 | 01-APR-05:15 | 7218.90 | 24-APR-07:42 | 6806.92 | 09-APR-21:52 | 2037.90 | 24-APR-07:42 | 1594.25 | 24-APR-07:42 | 0.00 |
| May | 0.503929E+10 | 0.149217E+10 | 741.44 | 0.447823E+10 | 0.561063E+09 | 0.00 | 1.00 | 13-MAY-07:52 | 0.00 | 13-MAY-05:15 | 7326.18 | 13-MAY-07:52 | 5045.84 | 13-MAY-07:52 | 2388.11 | 13-MAY-07:53 | 1566.48 | 13-MAY-07:53 | 0.00 |
| June | 0.526945E+10 | 0.155337E+10 | 717.36 | 0.437915E+10 | 0.890306E+09 | 0.00 | 1.00 | 18-JUN-06:52 | 0.00 | 18-JUN-05:13 | 7371.65 | 18-JUN-06:52 | 5102.02 | 27-JUN-11:52 | 2674.71 | 18-JUN-06:53 | 1571.47 | 18-JUN-06:53 | 0.00 |
| July | 0.562321E+10 | 0.158187E+10 | 744.00 | 0.423496E+10 | 0.138826E+10 | 0.00 | 0.58 | 02-JUL-16:20 | 0.14 | 19-JUL-03:20 | 3436.92 | 01-JUL-16:01 | 2870.38 | 02-JUL-16:20 | 746.22 | 01-JUL-16:01 | 1039.05 | 02-JUL-16:20 | 0.00 |
| August | 0.531481E+10 | 0.145392E+10 | 744.00 | 0.389835E+10 | 0.141647E+10 | 0.00 | 0.54 | 27-AUG-16:02 | 0.16 | 24-AUG-04:00 | 3309.56 | 27-AUG-16:02 | 2649.41 | 06-AUG-16:02 | 871.15 | 12-AUG-10:00 | 948.96 | 27-AUG-16:02 | 0.00 |
| September | 0.464597E+10 | 0.125854E+10 | 716.56 | 0.355411E+10 | 0.109186E+10 | 0.00 | 1.00 | 27-SEP-07:12 | 0.00 | 27-SEP-05:13 | 7251.93 | 27-SEP-07:12 | 5187.75 | 29-SEP-06:22 | 2151.65 | 27-SEP-07:12 | 1582.67 | 27-SEP-07:12 | 0.00 |
| October | 0.354781E+10 | 0.957112E+09 | 594.97 | 0.319525E+10 | 0.352557E+09 | 0.00 | 1.00 | 01-OCT-07:52 | 0.00 | 01-OCT-05:13 | 7490.12 | 13-OCT-09:12 | 6812.19 | 24-OCT-20:52 | 3121.82 | 13-OCT-09:13 | 1597.03 | 02-OCT-07:32 | 0.00 |
| November | 0.192301E+10 | 0.498464E+09 | 365.61 | 0.184270E+10 | 80316435.16 | 0.00 | 1.00 | 01-NOV-10:02 | 0.00 | 01-NOV-04:50 | 7124.46 | 09-NOV-09:32 | 6942.99 | 28-NOV-14:12 | 1430.25 | 18-NOV-10:33 | 1596.39 | 09-NOV-10:32 | 0.00 |
| December | 0.524722E+09 | 0.130279E+09 | 167.06 | 0.515037E+09 | 9684585.91 | 0.00 | 1.00 | 01-DEC-11:02 | 0.00 | 01-DEC-01:30 | 6986.59 | 10-DEC-19:22 | 6916.80 | 27-DEC-15:02 | 1069.16 | 10-DEC-19:22 | 1542.74 | 10-DEC-19:22 | 0.00 |
| Annual Sum or Average | 0.394128E+11 | 0.109883E+11 | 6284.35 | 0.332552E+11 | 0.615768E+10 | 0.00 | 0.00 | ||||||||||||
| Minimum of Months | 0.286517E+09 | 70873512.08 | 117.11 | 0.282068E+09 | 4449247.42 | 0.00 | 0.54 | 0.00 | 3309.56 | 2649.41 | 617.66 | 948.96 | 0.00 | ||||||
| Maximum of Months | 0.562321E+10 | 0.158187E+10 | 744.00 | 0.447823E+10 | 0.141647E+10 | 0.00 | 1.00 | 0.16 | 7490.12 | 6975.13 | 3121.82 | 1597.03 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 141.32 | 85.53 | 55.78 | 204.39 | 142.85 | 0.00 | 0.00 | 0.00 |
| February | 136.39 | 76.29 | 60.10 | 217.98 | 111.86 | 0.00 | 0.00 | 0.00 |
| March | 112.65 | 48.13 | 64.52 | 215.99 | 63.30 | 0.00 | 0.00 | 0.00 |
| April | 83.64 | 25.35 | 58.30 | 221.05 | 18.50 | 0.00 | 0.00 | 0.00 |
| May | 58.63 | 4.55 | 54.08 | 209.68 | 1.71 | 0.00 | 0.00 | 0.00 |
| June | 53.59 | 1.09 | 52.49 | 207.06 | 1.70 | 0.00 | 0.00 | 0.00 |
| July | 55.56 | 0.62 | 54.94 | 191.92 | 0.25 | 0.00 | 0.00 | 0.00 |
| August | 58.38 | 2.45 | 55.93 | 174.15 | 1.04 | 0.00 | 0.00 | 0.00 |
| September | 81.86 | 23.19 | 58.66 | 197.09 | 5.92 | 0.00 | 0.00 | 0.00 |
| October | 135.20 | 75.02 | 60.18 | 276.06 | 49.64 | 0.00 | 0.00 | 0.00 |
| November | 170.86 | 113.15 | 57.71 | 299.33 | 101.23 | 0.00 | 0.00 | 0.00 |
| December | 151.51 | 94.81 | 56.70 | 227.14 | 141.56 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 103.09 | 45.65 | 57.44 | 220.05 | 53.05 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 53.59 | 0.62 | 52.49 | 174.15 | 0.25 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 170.86 | 113.15 | 64.52 | 299.33 | 142.85 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 W SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 43.09 | 16.76 | 26.34 | 48.45 | 102.78 | 0.00 | 0.00 | 0.00 |
| February | 49.22 | 18.11 | 31.11 | 68.32 | 78.00 | 0.00 | 0.00 | 0.00 |
| March | 64.17 | 25.79 | 38.38 | 115.33 | 42.30 | 0.00 | 0.00 | 0.00 |
| April | 77.56 | 36.30 | 41.25 | 179.35 | 11.93 | 0.00 | 0.00 | 0.00 |
| May | 73.46 | 31.11 | 42.35 | 203.45 | 1.16 | 0.00 | 0.00 | 0.00 |
| June | 69.30 | 27.05 | 42.25 | 203.15 | 1.09 | 0.00 | 0.00 | 0.00 |
| July | 51.23 | 9.94 | 41.30 | 154.05 | 0.18 | 0.00 | 0.00 | 0.00 |
| August | 46.98 | 8.25 | 38.73 | 130.01 | 0.70 | 0.00 | 0.00 | 0.00 |
| September | 51.89 | 15.35 | 36.54 | 121.21 | 3.85 | 0.00 | 0.00 | 0.00 |
| October | 53.86 | 21.43 | 32.43 | 109.83 | 33.42 | 0.00 | 0.00 | 0.00 |
| November | 48.72 | 20.75 | 27.97 | 78.88 | 70.10 | 0.00 | 0.00 | 0.00 |
| December | 41.74 | 15.94 | 25.80 | 47.53 | 100.44 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 55.93 | 20.54 | 35.39 | 121.81 | 37.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.74 | 8.25 | 25.80 | 47.53 | 0.18 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.56 | 36.30 | 42.35 | 203.45 | 102.78 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 W NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 43.09 | 16.76 | 26.34 | 53.73 | 93.96 | 0.00 | 0.00 | 0.00 |
| February | 49.22 | 18.11 | 31.11 | 72.16 | 73.27 | 0.00 | 0.00 | 0.00 |
| March | 64.17 | 25.79 | 38.38 | 117.37 | 40.82 | 0.00 | 0.00 | 0.00 |
| April | 77.56 | 36.30 | 41.25 | 180.60 | 11.52 | 0.00 | 0.00 | 0.00 |
| May | 73.46 | 31.11 | 42.35 | 203.72 | 1.15 | 0.00 | 0.00 | 0.00 |
| June | 69.30 | 27.05 | 42.25 | 203.08 | 1.09 | 0.00 | 0.00 | 0.00 |
| July | 51.23 | 9.94 | 41.30 | 154.02 | 0.18 | 0.00 | 0.00 | 0.00 |
| August | 46.98 | 8.25 | 38.73 | 130.27 | 0.69 | 0.00 | 0.00 | 0.00 |
| September | 51.89 | 15.35 | 36.54 | 122.19 | 3.63 | 0.00 | 0.00 | 0.00 |
| October | 53.86 | 21.43 | 32.43 | 111.73 | 32.16 | 0.00 | 0.00 | 0.00 |
| November | 48.72 | 20.75 | 27.97 | 81.63 | 67.76 | 0.00 | 0.00 | 0.00 |
| December | 41.74 | 15.94 | 25.80 | 51.11 | 96.03 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 55.93 | 20.54 | 35.39 | 123.63 | 35.03 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.74 | 8.25 | 25.80 | 51.11 | 0.18 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.56 | 36.30 | 42.35 | 203.72 | 96.03 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 31.26 | 0.00 | 31.26 | 17.95 | 147.11 | 0.00 | 0.00 | 0.00 |
| February | 37.07 | 0.00 | 37.07 | 36.75 | 113.28 | 0.00 | 0.00 | 0.00 |
| March | 44.68 | 0.00 | 44.67 | 75.03 | 62.51 | 0.00 | 0.00 | 0.00 |
| April | 48.58 | 0.24 | 48.34 | 138.23 | 17.32 | 0.00 | 0.00 | 0.00 |
| May | 53.87 | 1.67 | 52.20 | 196.29 | 1.74 | 0.00 | 0.00 | 0.00 |
| June | 55.44 | 1.92 | 53.52 | 210.60 | 1.68 | 0.00 | 0.00 | 0.00 |
| July | 54.91 | 0.94 | 53.97 | 189.62 | 0.26 | 0.00 | 0.00 | 0.00 |
| August | 50.50 | 0.28 | 50.21 | 156.49 | 1.01 | 0.00 | 0.00 | 0.00 |
| September | 44.85 | 0.01 | 44.84 | 118.63 | 5.52 | 0.00 | 0.00 | 0.00 |
| October | 38.85 | 0.00 | 38.85 | 82.70 | 49.14 | 0.00 | 0.00 | 0.00 |
| November | 32.90 | 0.00 | 32.90 | 41.23 | 104.38 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 17.14 | 151.61 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 43.65 | 0.42 | 43.22 | 107.07 | 54.39 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 17.14 | 0.26 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 55.44 | 1.92 | 53.97 | 210.60 | 151.61 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 141.32 | 85.53 | 55.78 | 206.56 | 143.08 | 0.00 | 0.00 | 0.00 |
| February | 136.39 | 76.29 | 60.10 | 217.10 | 118.29 | 0.00 | 0.00 | 0.00 |
| March | 112.65 | 48.13 | 64.52 | 209.86 | 77.50 | 0.00 | 0.00 | 0.00 |
| April | 83.64 | 25.35 | 58.30 | 200.57 | 36.50 | 0.00 | 0.00 | 0.00 |
| May | 58.63 | 4.55 | 54.08 | 175.38 | 12.26 | 0.00 | 0.00 | 0.00 |
| June | 53.59 | 1.09 | 52.49 | 169.54 | 9.42 | 0.00 | 0.00 | 0.00 |
| July | 55.56 | 0.62 | 54.94 | 149.58 | 6.08 | 0.00 | 0.00 | 0.00 |
| August | 58.38 | 2.45 | 55.93 | 143.26 | 13.10 | 0.00 | 0.00 | 0.00 |
| September | 81.86 | 23.19 | 58.66 | 175.62 | 29.26 | 0.00 | 0.00 | 0.00 |
| October | 135.20 | 75.02 | 60.18 | 264.16 | 74.13 | 0.00 | 0.00 | 0.00 |
| November | 170.86 | 113.15 | 57.71 | 293.70 | 117.75 | 0.00 | 0.00 | 0.00 |
| December | 151.51 | 94.81 | 56.70 | 227.65 | 146.45 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 103.09 | 45.65 | 57.44 | 202.55 | 65.07 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 53.59 | 0.62 | 52.49 | 143.26 | 6.08 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 170.86 | 113.15 | 64.52 | 293.70 | 146.45 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 E SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.20 | 17.82 | 26.37 | 44.46 | 95.21 | 0.00 | 0.00 | 0.00 |
| February | 53.49 | 22.02 | 31.47 | 70.23 | 76.55 | 0.00 | 0.00 | 0.00 |
| March | 65.32 | 26.93 | 38.39 | 110.72 | 48.56 | 0.00 | 0.00 | 0.00 |
| April | 77.95 | 36.41 | 41.54 | 165.31 | 22.76 | 0.00 | 0.00 | 0.00 |
| May | 76.47 | 33.91 | 42.57 | 186.08 | 7.81 | 0.00 | 0.00 | 0.00 |
| June | 62.21 | 20.63 | 41.58 | 164.51 | 6.12 | 0.00 | 0.00 | 0.00 |
| July | 52.23 | 10.97 | 41.25 | 128.79 | 3.94 | 0.00 | 0.00 | 0.00 |
| August | 47.10 | 8.16 | 38.95 | 109.68 | 8.54 | 0.00 | 0.00 | 0.00 |
| September | 50.23 | 13.92 | 36.31 | 103.24 | 18.73 | 0.00 | 0.00 | 0.00 |
| October | 55.13 | 22.29 | 32.84 | 102.42 | 47.66 | 0.00 | 0.00 | 0.00 |
| November | 48.75 | 20.88 | 27.87 | 70.59 | 76.59 | 0.00 | 0.00 | 0.00 |
| December | 42.50 | 16.82 | 25.68 | 44.86 | 98.66 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 56.28 | 20.87 | 35.42 | 108.53 | 42.44 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 42.50 | 8.16 | 25.68 | 44.46 | 3.94 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.95 | 36.41 | 42.57 | 186.08 | 98.66 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 E NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.20 | 17.82 | 26.37 | 48.38 | 86.69 | 0.00 | 0.00 | 0.00 |
| February | 53.49 | 22.02 | 31.47 | 74.05 | 67.85 | 0.00 | 0.00 | 0.00 |
| March | 65.32 | 26.93 | 38.39 | 116.37 | 37.93 | 0.00 | 0.00 | 0.00 |
| April | 77.95 | 36.41 | 41.54 | 180.56 | 10.99 | 0.00 | 0.00 | 0.00 |
| May | 76.47 | 33.91 | 42.57 | 209.02 | 1.08 | 0.00 | 0.00 | 0.00 |
| June | 62.21 | 20.63 | 41.58 | 189.27 | 1.08 | 0.00 | 0.00 | 0.00 |
| July | 52.23 | 10.97 | 41.25 | 156.76 | 0.16 | 0.00 | 0.00 | 0.00 |
| August | 47.10 | 8.16 | 38.95 | 130.27 | 0.65 | 0.00 | 0.00 | 0.00 |
| September | 50.23 | 13.92 | 36.31 | 118.81 | 3.49 | 0.00 | 0.00 | 0.00 |
| October | 55.13 | 22.29 | 32.84 | 111.89 | 30.51 | 0.00 | 0.00 | 0.00 |
| November | 48.75 | 20.88 | 27.87 | 76.32 | 63.20 | 0.00 | 0.00 | 0.00 |
| December | 42.50 | 16.82 | 25.68 | 47.71 | 90.75 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 56.28 | 20.87 | 35.42 | 121.79 | 32.72 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 42.50 | 8.16 | 25.68 | 47.71 | 0.16 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.95 | 36.41 | 42.57 | 209.02 | 90.75 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 31.26 | 0.00 | 31.26 | 17.26 | 147.01 | 0.00 | 0.00 | 0.00 |
| February | 37.07 | 0.00 | 37.07 | 35.73 | 113.48 | 0.00 | 0.00 | 0.00 |
| March | 44.68 | 0.00 | 44.67 | 74.13 | 62.40 | 0.00 | 0.00 | 0.00 |
| April | 48.58 | 0.24 | 48.34 | 137.88 | 17.22 | 0.00 | 0.00 | 0.00 |
| May | 53.87 | 1.67 | 52.20 | 196.10 | 1.70 | 0.00 | 0.00 | 0.00 |
| June | 55.44 | 1.92 | 53.52 | 210.82 | 1.66 | 0.00 | 0.00 | 0.00 |
| July | 54.91 | 0.94 | 53.97 | 189.60 | 0.26 | 0.00 | 0.00 | 0.00 |
| August | 50.50 | 0.28 | 50.21 | 156.46 | 1.01 | 0.00 | 0.00 | 0.00 |
| September | 44.85 | 0.01 | 44.84 | 118.62 | 5.45 | 0.00 | 0.00 | 0.00 |
| October | 38.85 | 0.00 | 38.85 | 82.29 | 49.01 | 0.00 | 0.00 | 0.00 |
| November | 32.90 | 0.00 | 32.90 | 40.54 | 104.15 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 16.53 | 151.30 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 43.65 | 0.42 | 43.22 | 106.68 | 54.32 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 16.53 | 0.26 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 55.44 | 1.92 | 53.97 | 210.82 | 151.30 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N N1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 31.26 | 0.00 | 31.26 | 16.46 | 153.22 | 0.00 | 0.00 | 0.00 |
| February | 37.07 | 0.00 | 37.07 | 35.61 | 117.17 | 0.00 | 0.00 | 0.00 |
| March | 44.68 | 0.00 | 44.67 | 75.14 | 63.23 | 0.00 | 0.00 | 0.00 |
| April | 48.58 | 0.24 | 48.34 | 140.43 | 17.12 | 0.00 | 0.00 | 0.00 |
| May | 53.87 | 1.67 | 52.20 | 200.07 | 1.60 | 0.00 | 0.00 | 0.00 |
| June | 55.44 | 1.92 | 53.52 | 214.95 | 1.57 | 0.00 | 0.00 | 0.00 |
| July | 54.91 | 0.94 | 53.97 | 193.78 | 0.23 | 0.00 | 0.00 | 0.00 |
| August | 50.50 | 0.28 | 50.21 | 160.31 | 0.82 | 0.00 | 0.00 | 0.00 |
| September | 44.85 | 0.01 | 44.84 | 121.73 | 4.75 | 0.00 | 0.00 | 0.00 |
| October | 38.85 | 0.00 | 38.85 | 84.33 | 48.16 | 0.00 | 0.00 | 0.00 |
| November | 32.90 | 0.00 | 32.90 | 41.64 | 104.32 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 16.56 | 154.27 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 43.65 | 0.42 | 43.22 | 108.78 | 55.29 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 16.46 | 0.23 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 55.44 | 1.92 | 53.97 | 214.95 | 154.27 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 N N2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 31.26 | 0.00 | 31.26 | 16.42 | 153.26 | 0.00 | 0.00 | 0.00 |
| February | 37.07 | 0.00 | 37.07 | 35.54 | 117.24 | 0.00 | 0.00 | 0.00 |
| March | 44.68 | 0.00 | 44.67 | 75.09 | 63.24 | 0.00 | 0.00 | 0.00 |
| April | 48.58 | 0.24 | 48.34 | 140.42 | 17.12 | 0.00 | 0.00 | 0.00 |
| May | 53.87 | 1.67 | 52.20 | 200.06 | 1.60 | 0.00 | 0.00 | 0.00 |
| June | 55.44 | 1.92 | 53.52 | 214.96 | 1.57 | 0.00 | 0.00 | 0.00 |
| July | 54.91 | 0.94 | 53.97 | 193.78 | 0.23 | 0.00 | 0.00 | 0.00 |
| August | 50.50 | 0.28 | 50.21 | 160.30 | 0.82 | 0.00 | 0.00 | 0.00 |
| September | 44.85 | 0.01 | 44.84 | 121.73 | 4.75 | 0.00 | 0.00 | 0.00 |
| October | 38.85 | 0.00 | 38.85 | 84.31 | 48.16 | 0.00 | 0.00 | 0.00 |
| November | 32.90 | 0.00 | 32.90 | 41.61 | 104.33 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 16.53 | 154.28 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 43.65 | 0.42 | 43.22 | 108.76 | 55.30 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 16.42 | 0.23 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 55.44 | 1.92 | 53.97 | 214.96 | 154.28 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S S1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 141.32 | 85.53 | 55.78 | 202.56 | 146.49 | 0.00 | 0.00 | 0.00 |
| February | 136.39 | 76.29 | 60.10 | 216.82 | 114.24 | 0.00 | 0.00 | 0.00 |
| March | 112.65 | 48.13 | 64.52 | 215.83 | 64.08 | 0.00 | 0.00 | 0.00 |
| April | 83.64 | 25.35 | 58.30 | 222.98 | 18.36 | 0.00 | 0.00 | 0.00 |
| May | 58.63 | 4.55 | 54.08 | 213.34 | 1.59 | 0.00 | 0.00 | 0.00 |
| June | 53.59 | 1.09 | 52.49 | 211.35 | 1.59 | 0.00 | 0.00 | 0.00 |
| July | 55.56 | 0.62 | 54.94 | 196.04 | 0.23 | 0.00 | 0.00 | 0.00 |
| August | 58.38 | 2.45 | 55.93 | 177.86 | 0.86 | 0.00 | 0.00 | 0.00 |
| September | 81.86 | 23.19 | 58.66 | 199.93 | 5.18 | 0.00 | 0.00 | 0.00 |
| October | 135.20 | 75.02 | 60.18 | 277.37 | 48.87 | 0.00 | 0.00 | 0.00 |
| November | 170.86 | 113.15 | 57.71 | 299.39 | 101.54 | 0.00 | 0.00 | 0.00 |
| December | 151.51 | 94.81 | 56.70 | 226.20 | 143.45 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 103.09 | 45.65 | 57.44 | 221.55 | 53.62 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 53.59 | 0.62 | 52.49 | 177.86 | 0.23 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 170.86 | 113.15 | 64.52 | 299.39 | 146.49 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: GWINDOW1 S S2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 141.32 | 85.53 | 55.78 | 202.66 | 146.27 | 0.00 | 0.00 | 0.00 |
| February | 136.39 | 76.29 | 60.10 | 216.64 | 114.46 | 0.00 | 0.00 | 0.00 |
| March | 112.65 | 48.13 | 64.52 | 215.34 | 64.67 | 0.00 | 0.00 | 0.00 |
| April | 83.64 | 25.35 | 58.30 | 221.98 | 18.98 | 0.00 | 0.00 | 0.00 |
| May | 58.63 | 4.55 | 54.08 | 211.74 | 1.73 | 0.00 | 0.00 | 0.00 |
| June | 53.59 | 1.09 | 52.49 | 209.75 | 1.71 | 0.00 | 0.00 | 0.00 |
| July | 55.56 | 0.62 | 54.94 | 194.28 | 0.25 | 0.00 | 0.00 | 0.00 |
| August | 58.38 | 2.45 | 55.93 | 176.35 | 1.00 | 0.00 | 0.00 | 0.00 |
| September | 81.86 | 23.19 | 58.66 | 198.74 | 5.73 | 0.00 | 0.00 | 0.00 |
| October | 135.20 | 75.02 | 60.18 | 276.65 | 49.83 | 0.00 | 0.00 | 0.00 |
| November | 170.86 | 113.15 | 57.71 | 298.94 | 102.23 | 0.00 | 0.00 | 0.00 |
| December | 151.51 | 94.81 | 56.70 | 226.10 | 143.56 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 103.09 | 45.65 | 57.44 | 220.67 | 53.95 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 53.59 | 0.62 | 52.49 | 176.35 | 0.25 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 170.86 | 113.15 | 64.52 | 298.94 | 146.27 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 141.32 | 85.53 | 55.78 | 201.89 | 144.91 | 0.00 | 0.00 | 0.00 |
| February | 136.39 | 76.29 | 60.10 | 214.82 | 114.94 | 0.00 | 0.00 | 0.00 |
| March | 112.65 | 48.13 | 64.52 | 213.34 | 65.29 | 0.00 | 0.00 | 0.00 |
| April | 83.64 | 25.35 | 58.30 | 220.14 | 18.78 | 0.00 | 0.00 | 0.00 |
| May | 58.63 | 4.55 | 54.08 | 211.56 | 1.60 | 0.00 | 0.00 | 0.00 |
| June | 53.59 | 1.09 | 52.49 | 210.56 | 1.50 | 0.00 | 0.00 | 0.00 |
| July | 55.56 | 0.62 | 54.94 | 197.29 | 0.19 | 0.00 | 0.00 | 0.00 |
| August | 58.38 | 2.45 | 55.93 | 179.63 | 0.61 | 0.00 | 0.00 | 0.00 |
| September | 81.86 | 23.19 | 58.66 | 201.17 | 4.12 | 0.00 | 0.00 | 0.00 |
| October | 135.20 | 75.02 | 60.18 | 277.96 | 46.34 | 0.00 | 0.00 | 0.00 |
| November | 170.86 | 113.15 | 57.71 | 299.76 | 99.02 | 0.00 | 0.00 | 0.00 |
| December | 151.51 | 94.81 | 56.70 | 226.41 | 140.91 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 103.09 | 45.65 | 57.44 | 221.14 | 52.92 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 53.59 | 0.62 | 52.49 | 179.63 | 0.19 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 170.86 | 113.15 | 64.52 | 299.76 | 144.91 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 W SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 43.09 | 16.76 | 26.34 | 47.24 | 104.37 | 0.00 | 0.00 | 0.00 |
| February | 49.22 | 18.11 | 31.11 | 66.65 | 80.20 | 0.00 | 0.00 | 0.00 |
| March | 64.17 | 25.79 | 38.38 | 113.76 | 43.71 | 0.00 | 0.00 | 0.00 |
| April | 77.56 | 36.30 | 41.25 | 178.79 | 12.10 | 0.00 | 0.00 | 0.00 |
| May | 73.46 | 31.11 | 42.35 | 204.52 | 1.08 | 0.00 | 0.00 | 0.00 |
| June | 69.30 | 27.05 | 42.25 | 205.23 | 0.97 | 0.00 | 0.00 | 0.00 |
| July | 51.23 | 9.94 | 41.30 | 157.29 | 0.13 | 0.00 | 0.00 | 0.00 |
| August | 46.98 | 8.25 | 38.73 | 133.56 | 0.41 | 0.00 | 0.00 | 0.00 |
| September | 51.89 | 15.35 | 36.54 | 124.01 | 2.68 | 0.00 | 0.00 | 0.00 |
| October | 53.86 | 21.43 | 32.43 | 111.31 | 31.19 | 0.00 | 0.00 | 0.00 |
| November | 48.72 | 20.75 | 27.97 | 79.43 | 68.57 | 0.00 | 0.00 | 0.00 |
| December | 41.74 | 15.94 | 25.80 | 47.29 | 100.01 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 55.93 | 20.54 | 35.39 | 122.61 | 36.94 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.74 | 8.25 | 25.80 | 47.24 | 0.13 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.56 | 36.30 | 42.35 | 205.23 | 104.37 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 W NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 43.09 | 16.76 | 26.34 | 52.56 | 96.34 | 0.00 | 0.00 | 0.00 |
| February | 49.22 | 18.11 | 31.11 | 69.87 | 77.22 | 0.00 | 0.00 | 0.00 |
| March | 64.17 | 25.79 | 38.38 | 115.44 | 42.76 | 0.00 | 0.00 | 0.00 |
| April | 77.56 | 36.30 | 41.25 | 179.84 | 11.82 | 0.00 | 0.00 | 0.00 |
| May | 73.46 | 31.11 | 42.35 | 204.76 | 1.08 | 0.00 | 0.00 | 0.00 |
| June | 69.30 | 27.05 | 42.25 | 205.20 | 0.97 | 0.00 | 0.00 | 0.00 |
| July | 51.23 | 9.94 | 41.30 | 157.30 | 0.13 | 0.00 | 0.00 | 0.00 |
| August | 46.98 | 8.25 | 38.73 | 133.82 | 0.40 | 0.00 | 0.00 | 0.00 |
| September | 51.89 | 15.35 | 36.54 | 124.98 | 2.53 | 0.00 | 0.00 | 0.00 |
| October | 53.86 | 21.43 | 32.43 | 113.16 | 30.18 | 0.00 | 0.00 | 0.00 |
| November | 48.72 | 20.75 | 27.97 | 82.30 | 66.45 | 0.00 | 0.00 | 0.00 |
| December | 41.74 | 15.94 | 25.80 | 51.52 | 94.86 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 55.93 | 20.54 | 35.39 | 124.41 | 35.22 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.74 | 8.25 | 25.80 | 51.52 | 0.13 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.56 | 36.30 | 42.35 | 205.20 | 96.34 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 31.26 | 0.00 | 31.26 | 16.90 | 150.87 | 0.00 | 0.00 | 0.00 |
| February | 37.07 | 0.00 | 37.07 | 34.15 | 119.52 | 0.00 | 0.00 | 0.00 |
| March | 44.68 | 0.00 | 44.67 | 72.72 | 65.43 | 0.00 | 0.00 | 0.00 |
| April | 48.58 | 0.24 | 48.34 | 137.74 | 17.74 | 0.00 | 0.00 | 0.00 |
| May | 53.87 | 1.67 | 52.20 | 198.24 | 1.63 | 0.00 | 0.00 | 0.00 |
| June | 55.44 | 1.92 | 53.52 | 214.17 | 1.49 | 0.00 | 0.00 | 0.00 |
| July | 54.91 | 0.94 | 53.97 | 194.91 | 0.19 | 0.00 | 0.00 | 0.00 |
| August | 50.50 | 0.28 | 50.21 | 162.10 | 0.58 | 0.00 | 0.00 | 0.00 |
| September | 44.85 | 0.01 | 44.84 | 123.32 | 3.83 | 0.00 | 0.00 | 0.00 |
| October | 38.85 | 0.00 | 38.85 | 85.33 | 46.05 | 0.00 | 0.00 | 0.00 |
| November | 32.90 | 0.00 | 32.90 | 42.60 | 102.14 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 17.88 | 149.46 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 43.65 | 0.42 | 43.22 | 108.72 | 54.64 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 16.90 | 0.19 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 55.44 | 1.92 | 53.97 | 214.17 | 150.87 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 141.32 | 85.53 | 55.78 | 201.15 | 144.51 | 0.00 | 0.00 | 0.00 |
| February | 136.39 | 76.29 | 60.10 | 213.76 | 114.73 | 0.00 | 0.00 | 0.00 |
| March | 112.65 | 48.13 | 64.52 | 212.36 | 65.10 | 0.00 | 0.00 | 0.00 |
| April | 83.64 | 25.35 | 58.30 | 219.80 | 18.64 | 0.00 | 0.00 | 0.00 |
| May | 58.63 | 4.55 | 54.08 | 211.39 | 1.57 | 0.00 | 0.00 | 0.00 |
| June | 53.59 | 1.09 | 52.49 | 210.75 | 1.48 | 0.00 | 0.00 | 0.00 |
| July | 55.56 | 0.62 | 54.94 | 197.27 | 0.19 | 0.00 | 0.00 | 0.00 |
| August | 58.38 | 2.45 | 55.93 | 179.61 | 0.61 | 0.00 | 0.00 | 0.00 |
| September | 81.86 | 23.19 | 58.66 | 201.17 | 4.06 | 0.00 | 0.00 | 0.00 |
| October | 135.20 | 75.02 | 60.18 | 277.53 | 46.17 | 0.00 | 0.00 | 0.00 |
| November | 170.86 | 113.15 | 57.71 | 298.97 | 98.72 | 0.00 | 0.00 | 0.00 |
| December | 151.51 | 94.81 | 56.70 | 225.63 | 140.61 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 103.09 | 45.65 | 57.44 | 220.71 | 52.77 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 53.59 | 0.62 | 52.49 | 179.61 | 0.19 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 170.86 | 113.15 | 64.52 | 298.97 | 144.51 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 E SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.20 | 17.82 | 26.37 | 41.83 | 96.52 | 0.00 | 0.00 | 0.00 |
| February | 53.49 | 22.02 | 31.47 | 68.46 | 74.24 | 0.00 | 0.00 | 0.00 |
| March | 65.32 | 26.93 | 38.39 | 112.57 | 40.48 | 0.00 | 0.00 | 0.00 |
| April | 77.95 | 36.41 | 41.54 | 178.72 | 11.51 | 0.00 | 0.00 | 0.00 |
| May | 76.47 | 33.91 | 42.57 | 209.67 | 1.01 | 0.00 | 0.00 | 0.00 |
| June | 62.21 | 20.63 | 41.58 | 191.38 | 0.96 | 0.00 | 0.00 | 0.00 |
| July | 52.23 | 10.97 | 41.25 | 160.21 | 0.12 | 0.00 | 0.00 | 0.00 |
| August | 47.10 | 8.16 | 38.95 | 133.54 | 0.38 | 0.00 | 0.00 | 0.00 |
| September | 50.23 | 13.92 | 36.31 | 120.71 | 2.59 | 0.00 | 0.00 | 0.00 |
| October | 55.13 | 22.29 | 32.84 | 111.64 | 29.63 | 0.00 | 0.00 | 0.00 |
| November | 48.75 | 20.88 | 27.87 | 74.27 | 64.07 | 0.00 | 0.00 | 0.00 |
| December | 42.50 | 16.82 | 25.68 | 44.29 | 95.02 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 56.28 | 20.87 | 35.42 | 120.81 | 34.55 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 42.50 | 8.16 | 25.68 | 41.83 | 0.12 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.95 | 36.41 | 42.57 | 209.67 | 96.52 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 E NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.20 | 17.82 | 26.37 | 47.09 | 88.90 | 0.00 | 0.00 | 0.00 |
| February | 53.49 | 22.02 | 31.47 | 71.55 | 71.38 | 0.00 | 0.00 | 0.00 |
| March | 65.32 | 26.93 | 38.39 | 114.20 | 39.62 | 0.00 | 0.00 | 0.00 |
| April | 77.95 | 36.41 | 41.54 | 179.77 | 11.25 | 0.00 | 0.00 | 0.00 |
| May | 76.47 | 33.91 | 42.57 | 209.92 | 1.01 | 0.00 | 0.00 | 0.00 |
| June | 62.21 | 20.63 | 41.58 | 191.35 | 0.96 | 0.00 | 0.00 | 0.00 |
| July | 52.23 | 10.97 | 41.25 | 160.22 | 0.12 | 0.00 | 0.00 | 0.00 |
| August | 47.10 | 8.16 | 38.95 | 133.80 | 0.38 | 0.00 | 0.00 | 0.00 |
| September | 50.23 | 13.92 | 36.31 | 121.69 | 2.44 | 0.00 | 0.00 | 0.00 |
| October | 55.13 | 22.29 | 32.84 | 113.50 | 28.70 | 0.00 | 0.00 | 0.00 |
| November | 48.75 | 20.88 | 27.87 | 77.14 | 61.84 | 0.00 | 0.00 | 0.00 |
| December | 42.50 | 16.82 | 25.68 | 48.17 | 89.66 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 56.28 | 20.87 | 35.42 | 122.56 | 32.86 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 42.50 | 8.16 | 25.68 | 47.09 | 0.12 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.95 | 36.41 | 42.57 | 209.92 | 89.66 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 31.26 | 0.00 | 31.26 | 16.07 | 150.77 | 0.00 | 0.00 | 0.00 |
| February | 37.07 | 0.00 | 37.07 | 33.03 | 119.50 | 0.00 | 0.00 | 0.00 |
| March | 44.68 | 0.00 | 44.67 | 71.66 | 65.31 | 0.00 | 0.00 | 0.00 |
| April | 48.58 | 0.24 | 48.34 | 137.37 | 17.62 | 0.00 | 0.00 | 0.00 |
| May | 53.87 | 1.67 | 52.20 | 198.07 | 1.59 | 0.00 | 0.00 | 0.00 |
| June | 55.44 | 1.92 | 53.52 | 214.35 | 1.47 | 0.00 | 0.00 | 0.00 |
| July | 54.91 | 0.94 | 53.97 | 194.89 | 0.19 | 0.00 | 0.00 | 0.00 |
| August | 50.50 | 0.28 | 50.21 | 162.07 | 0.59 | 0.00 | 0.00 | 0.00 |
| September | 44.85 | 0.01 | 44.84 | 123.31 | 3.77 | 0.00 | 0.00 | 0.00 |
| October | 38.85 | 0.00 | 38.85 | 84.84 | 45.90 | 0.00 | 0.00 | 0.00 |
| November | 32.90 | 0.00 | 32.90 | 41.79 | 101.70 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 17.10 | 149.16 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 43.65 | 0.42 | 43.22 | 108.26 | 54.52 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 16.07 | 0.19 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 55.44 | 1.92 | 53.97 | 214.35 | 150.77 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N N1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 31.26 | 0.00 | 31.26 | 15.08 | 157.93 | 0.00 | 0.00 | 0.00 |
| February | 37.07 | 0.00 | 37.07 | 33.63 | 121.69 | 0.00 | 0.00 | 0.00 |
| March | 44.68 | 0.00 | 44.67 | 73.55 | 65.19 | 0.00 | 0.00 | 0.00 |
| April | 48.58 | 0.24 | 48.34 | 140.62 | 17.20 | 0.00 | 0.00 | 0.00 |
| May | 53.87 | 1.67 | 52.20 | 202.38 | 1.47 | 0.00 | 0.00 | 0.00 |
| June | 55.44 | 1.92 | 53.52 | 218.35 | 1.39 | 0.00 | 0.00 | 0.00 |
| July | 54.91 | 0.94 | 53.97 | 198.34 | 0.19 | 0.00 | 0.00 | 0.00 |
| August | 50.50 | 0.28 | 50.21 | 164.97 | 0.52 | 0.00 | 0.00 | 0.00 |
| September | 44.85 | 0.01 | 44.84 | 125.69 | 3.53 | 0.00 | 0.00 | 0.00 |
| October | 38.85 | 0.00 | 38.85 | 86.51 | 45.69 | 0.00 | 0.00 | 0.00 |
| November | 32.90 | 0.00 | 32.90 | 42.73 | 102.35 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 16.72 | 153.91 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 43.65 | 0.42 | 43.22 | 110.27 | 55.65 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 15.08 | 0.19 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 55.44 | 1.92 | 53.97 | 218.35 | 157.93 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 N N2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 31.26 | 0.00 | 31.26 | 15.03 | 157.98 | 0.00 | 0.00 | 0.00 |
| February | 37.07 | 0.00 | 37.07 | 33.56 | 121.73 | 0.00 | 0.00 | 0.00 |
| March | 44.68 | 0.00 | 44.67 | 73.50 | 65.20 | 0.00 | 0.00 | 0.00 |
| April | 48.58 | 0.24 | 48.34 | 140.61 | 17.20 | 0.00 | 0.00 | 0.00 |
| May | 53.87 | 1.67 | 52.20 | 202.37 | 1.47 | 0.00 | 0.00 | 0.00 |
| June | 55.44 | 1.92 | 53.52 | 218.36 | 1.39 | 0.00 | 0.00 | 0.00 |
| July | 54.91 | 0.94 | 53.97 | 198.34 | 0.19 | 0.00 | 0.00 | 0.00 |
| August | 50.50 | 0.28 | 50.21 | 164.96 | 0.52 | 0.00 | 0.00 | 0.00 |
| September | 44.85 | 0.01 | 44.84 | 125.69 | 3.53 | 0.00 | 0.00 | 0.00 |
| October | 38.85 | 0.00 | 38.85 | 86.49 | 45.69 | 0.00 | 0.00 | 0.00 |
| November | 32.90 | 0.00 | 32.90 | 42.69 | 102.34 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 16.68 | 153.94 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 43.65 | 0.42 | 43.22 | 110.24 | 55.66 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 15.03 | 0.19 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 55.44 | 1.92 | 53.97 | 218.36 | 157.98 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S S1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 141.32 | 85.53 | 55.78 | 200.16 | 148.26 | 0.00 | 0.00 | 0.00 |
| February | 136.39 | 76.29 | 60.10 | 214.24 | 116.35 | 0.00 | 0.00 | 0.00 |
| March | 112.65 | 48.13 | 64.52 | 213.93 | 65.19 | 0.00 | 0.00 | 0.00 |
| April | 83.64 | 25.35 | 58.30 | 222.77 | 18.25 | 0.00 | 0.00 | 0.00 |
| May | 58.63 | 4.55 | 54.08 | 215.65 | 1.45 | 0.00 | 0.00 | 0.00 |
| June | 53.59 | 1.09 | 52.49 | 214.75 | 1.41 | 0.00 | 0.00 | 0.00 |
| July | 55.56 | 0.62 | 54.94 | 200.75 | 0.19 | 0.00 | 0.00 | 0.00 |
| August | 58.38 | 2.45 | 55.93 | 182.44 | 0.54 | 0.00 | 0.00 | 0.00 |
| September | 81.86 | 23.19 | 58.66 | 203.37 | 3.83 | 0.00 | 0.00 | 0.00 |
| October | 135.20 | 75.02 | 60.18 | 278.88 | 46.08 | 0.00 | 0.00 | 0.00 |
| November | 170.86 | 113.15 | 57.71 | 299.57 | 99.63 | 0.00 | 0.00 | 0.00 |
| December | 151.51 | 94.81 | 56.70 | 225.21 | 143.07 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 103.09 | 45.65 | 57.44 | 222.58 | 53.42 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 53.59 | 0.62 | 52.49 | 182.44 | 0.19 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 170.86 | 113.15 | 64.52 | 299.57 | 148.26 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW1 S S2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 141.32 | 85.53 | 55.78 | 200.13 | 148.25 | 0.00 | 0.00 | 0.00 |
| February | 136.39 | 76.29 | 60.10 | 214.19 | 116.36 | 0.00 | 0.00 | 0.00 |
| March | 112.65 | 48.13 | 64.52 | 213.89 | 65.19 | 0.00 | 0.00 | 0.00 |
| April | 83.64 | 25.35 | 58.30 | 222.75 | 18.24 | 0.00 | 0.00 | 0.00 |
| May | 58.63 | 4.55 | 54.08 | 215.64 | 1.45 | 0.00 | 0.00 | 0.00 |
| June | 53.59 | 1.09 | 52.49 | 214.75 | 1.41 | 0.00 | 0.00 | 0.00 |
| July | 55.56 | 0.62 | 54.94 | 200.75 | 0.19 | 0.00 | 0.00 | 0.00 |
| August | 58.38 | 2.45 | 55.93 | 182.44 | 0.54 | 0.00 | 0.00 | 0.00 |
| September | 81.86 | 23.19 | 58.66 | 203.37 | 3.82 | 0.00 | 0.00 | 0.00 |
| October | 135.20 | 75.02 | 60.18 | 278.87 | 46.08 | 0.00 | 0.00 | 0.00 |
| November | 170.86 | 113.15 | 57.71 | 299.54 | 99.63 | 0.00 | 0.00 | 0.00 |
| December | 151.51 | 94.81 | 56.70 | 225.17 | 143.07 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 103.09 | 45.65 | 57.44 | 222.56 | 53.42 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 53.59 | 0.62 | 52.49 | 182.44 | 0.19 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 170.86 | 113.15 | 64.52 | 299.54 | 148.25 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 141.32 | 85.53 | 55.78 | 207.41 | 128.21 | 0.00 | 0.00 | 0.00 |
| February | 136.39 | 76.29 | 60.10 | 216.67 | 104.58 | 0.00 | 0.00 | 0.00 |
| March | 112.65 | 48.13 | 64.52 | 211.40 | 62.10 | 0.00 | 0.00 | 0.00 |
| April | 83.64 | 25.35 | 58.30 | 215.20 | 17.68 | 0.00 | 0.00 | 0.00 |
| May | 58.63 | 4.55 | 54.08 | 205.61 | 1.49 | 0.00 | 0.00 | 0.00 |
| June | 53.59 | 1.09 | 52.49 | 204.14 | 1.49 | 0.00 | 0.00 | 0.00 |
| July | 55.56 | 0.62 | 54.94 | 191.64 | 0.18 | 0.00 | 0.00 | 0.00 |
| August | 58.38 | 2.45 | 55.93 | 174.64 | 0.59 | 0.00 | 0.00 | 0.00 |
| September | 81.86 | 23.19 | 58.66 | 196.77 | 3.83 | 0.00 | 0.00 | 0.00 |
| October | 135.20 | 75.02 | 60.18 | 275.06 | 44.07 | 0.00 | 0.00 | 0.00 |
| November | 170.86 | 113.15 | 57.71 | 299.58 | 92.84 | 0.00 | 0.00 | 0.00 |
| December | 151.51 | 94.81 | 56.70 | 231.51 | 125.98 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 103.09 | 45.65 | 57.44 | 219.05 | 48.34 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 53.59 | 0.62 | 52.49 | 174.64 | 0.18 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 170.86 | 113.15 | 64.52 | 299.58 | 128.21 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 W SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 43.09 | 16.76 | 26.34 | 48.25 | 90.81 | 0.00 | 0.00 | 0.00 |
| February | 49.22 | 18.11 | 31.11 | 66.46 | 72.03 | 0.00 | 0.00 | 0.00 |
| March | 64.17 | 25.79 | 38.38 | 112.05 | 41.25 | 0.00 | 0.00 | 0.00 |
| April | 77.56 | 36.30 | 41.25 | 175.39 | 11.33 | 0.00 | 0.00 | 0.00 |
| May | 73.46 | 31.11 | 42.35 | 200.49 | 1.01 | 0.00 | 0.00 | 0.00 |
| June | 69.30 | 27.05 | 42.25 | 200.91 | 0.95 | 0.00 | 0.00 | 0.00 |
| July | 51.23 | 9.94 | 41.30 | 153.46 | 0.13 | 0.00 | 0.00 | 0.00 |
| August | 46.98 | 8.25 | 38.73 | 130.18 | 0.39 | 0.00 | 0.00 | 0.00 |
| September | 51.89 | 15.35 | 36.54 | 121.08 | 2.48 | 0.00 | 0.00 | 0.00 |
| October | 53.86 | 21.43 | 32.43 | 109.12 | 29.48 | 0.00 | 0.00 | 0.00 |
| November | 48.72 | 20.75 | 27.97 | 78.38 | 63.64 | 0.00 | 0.00 | 0.00 |
| December | 41.74 | 15.94 | 25.80 | 48.19 | 87.77 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 55.93 | 20.54 | 35.39 | 120.51 | 33.28 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.74 | 8.25 | 25.80 | 48.19 | 0.13 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.56 | 36.30 | 42.35 | 200.91 | 90.81 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 W NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 43.09 | 16.76 | 26.34 | 55.56 | 84.13 | 0.00 | 0.00 | 0.00 |
| February | 49.22 | 18.11 | 31.11 | 71.82 | 68.54 | 0.00 | 0.00 | 0.00 |
| March | 64.17 | 25.79 | 38.38 | 114.57 | 40.37 | 0.00 | 0.00 | 0.00 |
| April | 77.56 | 36.30 | 41.25 | 176.78 | 11.15 | 0.00 | 0.00 | 0.00 |
| May | 73.46 | 31.11 | 42.35 | 200.78 | 1.01 | 0.00 | 0.00 | 0.00 |
| June | 69.30 | 27.05 | 42.25 | 200.89 | 0.95 | 0.00 | 0.00 | 0.00 |
| July | 51.23 | 9.94 | 41.30 | 153.47 | 0.13 | 0.00 | 0.00 | 0.00 |
| August | 46.98 | 8.25 | 38.73 | 130.50 | 0.39 | 0.00 | 0.00 | 0.00 |
| September | 51.89 | 15.35 | 36.54 | 122.34 | 2.39 | 0.00 | 0.00 | 0.00 |
| October | 53.86 | 21.43 | 32.43 | 111.82 | 28.67 | 0.00 | 0.00 | 0.00 |
| November | 48.72 | 20.75 | 27.97 | 83.25 | 60.92 | 0.00 | 0.00 | 0.00 |
| December | 41.74 | 15.94 | 25.80 | 55.73 | 80.96 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 55.93 | 20.54 | 35.39 | 123.30 | 31.47 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 41.74 | 8.25 | 25.80 | 55.56 | 0.13 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.56 | 36.30 | 42.35 | 200.89 | 84.13 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 31.26 | 0.00 | 31.26 | 21.23 | 132.12 | 0.00 | 0.00 | 0.00 |
| February | 37.07 | 0.00 | 37.07 | 37.38 | 106.53 | 0.00 | 0.00 | 0.00 |
| March | 44.68 | 0.00 | 44.67 | 71.74 | 61.95 | 0.00 | 0.00 | 0.00 |
| April | 48.58 | 0.24 | 48.34 | 133.38 | 16.78 | 0.00 | 0.00 | 0.00 |
| May | 53.87 | 1.67 | 52.20 | 192.32 | 1.53 | 0.00 | 0.00 | 0.00 |
| June | 55.44 | 1.92 | 53.52 | 207.74 | 1.46 | 0.00 | 0.00 | 0.00 |
| July | 54.91 | 0.94 | 53.97 | 189.25 | 0.18 | 0.00 | 0.00 | 0.00 |
| August | 50.50 | 0.28 | 50.21 | 157.17 | 0.57 | 0.00 | 0.00 | 0.00 |
| September | 44.85 | 0.01 | 44.84 | 119.41 | 3.61 | 0.00 | 0.00 | 0.00 |
| October | 38.85 | 0.00 | 38.85 | 83.42 | 43.83 | 0.00 | 0.00 | 0.00 |
| November | 32.90 | 0.00 | 32.90 | 44.25 | 93.94 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 23.54 | 127.78 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 43.65 | 0.42 | 43.22 | 107.09 | 48.94 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 21.23 | 0.18 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 55.44 | 1.92 | 53.97 | 207.74 | 132.12 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 141.32 | 85.53 | 55.78 | 205.51 | 127.30 | 0.00 | 0.00 | 0.00 |
| February | 136.39 | 76.29 | 60.10 | 214.44 | 103.93 | 0.00 | 0.00 | 0.00 |
| March | 112.65 | 48.13 | 64.52 | 209.73 | 61.59 | 0.00 | 0.00 | 0.00 |
| April | 83.64 | 25.35 | 58.30 | 214.69 | 17.47 | 0.00 | 0.00 | 0.00 |
| May | 58.63 | 4.55 | 54.08 | 205.37 | 1.45 | 0.00 | 0.00 | 0.00 |
| June | 53.59 | 1.09 | 52.49 | 204.36 | 1.46 | 0.00 | 0.00 | 0.00 |
| July | 55.56 | 0.62 | 54.94 | 191.61 | 0.18 | 0.00 | 0.00 | 0.00 |
| August | 58.38 | 2.45 | 55.93 | 174.61 | 0.59 | 0.00 | 0.00 | 0.00 |
| September | 81.86 | 23.19 | 58.66 | 196.74 | 3.76 | 0.00 | 0.00 | 0.00 |
| October | 135.20 | 75.02 | 60.18 | 274.34 | 43.73 | 0.00 | 0.00 | 0.00 |
| November | 170.86 | 113.15 | 57.71 | 298.15 | 92.10 | 0.00 | 0.00 | 0.00 |
| December | 151.51 | 94.81 | 56.70 | 229.76 | 125.15 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 103.09 | 45.65 | 57.44 | 218.20 | 47.98 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 53.59 | 0.62 | 52.49 | 174.61 | 0.18 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 170.86 | 113.15 | 64.52 | 298.15 | 127.30 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 E SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.20 | 17.82 | 26.37 | 45.53 | 85.96 | 0.00 | 0.00 | 0.00 |
| February | 53.49 | 22.02 | 31.47 | 69.69 | 67.80 | 0.00 | 0.00 | 0.00 |
| March | 65.32 | 26.93 | 38.39 | 111.35 | 38.59 | 0.00 | 0.00 | 0.00 |
| April | 77.95 | 36.41 | 41.54 | 175.36 | 10.85 | 0.00 | 0.00 | 0.00 |
| May | 76.47 | 33.91 | 42.57 | 205.47 | 0.94 | 0.00 | 0.00 | 0.00 |
| June | 62.21 | 20.63 | 41.58 | 187.02 | 0.95 | 0.00 | 0.00 | 0.00 |
| July | 52.23 | 10.97 | 41.25 | 156.36 | 0.12 | 0.00 | 0.00 | 0.00 |
| August | 47.10 | 8.16 | 38.95 | 130.13 | 0.37 | 0.00 | 0.00 | 0.00 |
| September | 50.23 | 13.92 | 36.31 | 117.76 | 2.40 | 0.00 | 0.00 | 0.00 |
| October | 55.13 | 22.29 | 32.84 | 109.71 | 28.20 | 0.00 | 0.00 | 0.00 |
| November | 48.75 | 20.88 | 27.87 | 74.21 | 60.11 | 0.00 | 0.00 | 0.00 |
| December | 42.50 | 16.82 | 25.68 | 47.51 | 85.30 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 56.28 | 20.87 | 35.42 | 119.37 | 31.65 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 42.50 | 8.16 | 25.68 | 45.53 | 0.12 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.95 | 36.41 | 42.57 | 205.47 | 85.96 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 E NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 44.20 | 17.82 | 26.37 | 51.94 | 78.00 | 0.00 | 0.00 | 0.00 |
| February | 53.49 | 22.02 | 31.47 | 74.78 | 64.06 | 0.00 | 0.00 | 0.00 |
| March | 65.32 | 26.93 | 38.39 | 113.70 | 37.73 | 0.00 | 0.00 | 0.00 |
| April | 77.95 | 36.41 | 41.54 | 176.74 | 10.67 | 0.00 | 0.00 | 0.00 |
| May | 76.47 | 33.91 | 42.57 | 205.77 | 0.94 | 0.00 | 0.00 | 0.00 |
| June | 62.21 | 20.63 | 41.58 | 186.99 | 0.94 | 0.00 | 0.00 | 0.00 |
| July | 52.23 | 10.97 | 41.25 | 156.37 | 0.12 | 0.00 | 0.00 | 0.00 |
| August | 47.10 | 8.16 | 38.95 | 130.45 | 0.36 | 0.00 | 0.00 | 0.00 |
| September | 50.23 | 13.92 | 36.31 | 119.02 | 2.30 | 0.00 | 0.00 | 0.00 |
| October | 55.13 | 22.29 | 32.84 | 112.34 | 27.41 | 0.00 | 0.00 | 0.00 |
| November | 48.75 | 20.88 | 27.87 | 78.94 | 57.06 | 0.00 | 0.00 | 0.00 |
| December | 42.50 | 16.82 | 25.68 | 53.94 | 77.15 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 56.28 | 20.87 | 35.42 | 121.93 | 29.58 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 42.50 | 8.16 | 25.68 | 51.94 | 0.12 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 77.95 | 36.41 | 42.57 | 205.77 | 78.00 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 31.26 | 0.00 | 31.26 | 19.82 | 130.69 | 0.00 | 0.00 | 0.00 |
| February | 37.07 | 0.00 | 37.07 | 35.15 | 105.67 | 0.00 | 0.00 | 0.00 |
| March | 44.68 | 0.00 | 44.67 | 69.89 | 61.46 | 0.00 | 0.00 | 0.00 |
| April | 48.58 | 0.24 | 48.34 | 132.84 | 16.58 | 0.00 | 0.00 | 0.00 |
| May | 53.87 | 1.67 | 52.20 | 192.08 | 1.49 | 0.00 | 0.00 | 0.00 |
| June | 55.44 | 1.92 | 53.52 | 207.96 | 1.44 | 0.00 | 0.00 | 0.00 |
| July | 54.91 | 0.94 | 53.97 | 189.22 | 0.18 | 0.00 | 0.00 | 0.00 |
| August | 50.50 | 0.28 | 50.21 | 157.13 | 0.57 | 0.00 | 0.00 | 0.00 |
| September | 44.85 | 0.01 | 44.84 | 119.39 | 3.54 | 0.00 | 0.00 | 0.00 |
| October | 38.85 | 0.00 | 38.85 | 82.61 | 43.50 | 0.00 | 0.00 | 0.00 |
| November | 32.90 | 0.00 | 32.90 | 42.63 | 92.73 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 21.88 | 126.27 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 43.65 | 0.42 | 43.22 | 106.25 | 48.43 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 19.82 | 0.18 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 55.44 | 1.92 | 53.97 | 207.96 | 130.69 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N N1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 31.26 | 0.00 | 31.26 | 20.89 | 135.13 | 0.00 | 0.00 | 0.00 |
| February | 37.07 | 0.00 | 37.07 | 36.99 | 109.44 | 0.00 | 0.00 | 0.00 |
| March | 44.68 | 0.00 | 44.67 | 72.74 | 62.56 | 0.00 | 0.00 | 0.00 |
| April | 48.58 | 0.24 | 48.34 | 137.00 | 16.55 | 0.00 | 0.00 | 0.00 |
| May | 53.87 | 1.67 | 52.20 | 197.19 | 1.44 | 0.00 | 0.00 | 0.00 |
| June | 55.44 | 1.92 | 53.52 | 212.66 | 1.43 | 0.00 | 0.00 | 0.00 |
| July | 54.91 | 0.94 | 53.97 | 193.23 | 0.18 | 0.00 | 0.00 | 0.00 |
| August | 50.50 | 0.28 | 50.21 | 160.52 | 0.53 | 0.00 | 0.00 | 0.00 |
| September | 44.85 | 0.01 | 44.84 | 122.31 | 3.44 | 0.00 | 0.00 | 0.00 |
| October | 38.85 | 0.00 | 38.85 | 85.01 | 43.98 | 0.00 | 0.00 | 0.00 |
| November | 32.90 | 0.00 | 32.90 | 44.15 | 95.94 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 22.73 | 131.41 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 43.65 | 0.42 | 43.22 | 109.15 | 49.91 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 20.89 | 0.18 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 55.44 | 1.92 | 53.97 | 212.66 | 135.13 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 N N2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 31.26 | 0.00 | 31.26 | 20.77 | 135.04 | 0.00 | 0.00 | 0.00 |
| February | 37.07 | 0.00 | 37.07 | 36.80 | 109.42 | 0.00 | 0.00 | 0.00 |
| March | 44.68 | 0.00 | 44.67 | 72.61 | 62.54 | 0.00 | 0.00 | 0.00 |
| April | 48.58 | 0.24 | 48.34 | 136.97 | 16.54 | 0.00 | 0.00 | 0.00 |
| May | 53.87 | 1.67 | 52.20 | 197.18 | 1.44 | 0.00 | 0.00 | 0.00 |
| June | 55.44 | 1.92 | 53.52 | 212.67 | 1.42 | 0.00 | 0.00 | 0.00 |
| July | 54.91 | 0.94 | 53.97 | 193.23 | 0.18 | 0.00 | 0.00 | 0.00 |
| August | 50.50 | 0.28 | 50.21 | 160.52 | 0.53 | 0.00 | 0.00 | 0.00 |
| September | 44.85 | 0.01 | 44.84 | 122.30 | 3.44 | 0.00 | 0.00 | 0.00 |
| October | 38.85 | 0.00 | 38.85 | 84.96 | 43.96 | 0.00 | 0.00 | 0.00 |
| November | 32.90 | 0.00 | 32.90 | 44.04 | 95.86 | 0.00 | 0.00 | 0.00 |
| December | 30.49 | 0.00 | 30.49 | 22.60 | 131.32 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 43.65 | 0.42 | 43.22 | 109.09 | 49.88 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 30.49 | 0.00 | 30.49 | 20.77 | 0.18 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 55.44 | 1.92 | 53.97 | 212.67 | 135.04 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S S1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 141.32 | 85.53 | 55.78 | 205.18 | 133.40 | 0.00 | 0.00 | 0.00 |
| February | 136.39 | 76.29 | 60.10 | 215.11 | 108.24 | 0.00 | 0.00 | 0.00 |
| March | 112.65 | 48.13 | 64.52 | 212.05 | 62.71 | 0.00 | 0.00 | 0.00 |
| April | 83.64 | 25.35 | 58.30 | 218.51 | 17.46 | 0.00 | 0.00 | 0.00 |
| May | 58.63 | 4.55 | 54.08 | 210.41 | 1.40 | 0.00 | 0.00 | 0.00 |
| June | 53.59 | 1.09 | 52.49 | 209.06 | 1.45 | 0.00 | 0.00 | 0.00 |
| July | 55.56 | 0.62 | 54.94 | 195.66 | 0.18 | 0.00 | 0.00 | 0.00 |
| August | 58.38 | 2.45 | 55.93 | 177.93 | 0.55 | 0.00 | 0.00 | 0.00 |
| September | 81.86 | 23.19 | 58.66 | 199.44 | 3.67 | 0.00 | 0.00 | 0.00 |
| October | 135.20 | 75.02 | 60.18 | 276.27 | 44.23 | 0.00 | 0.00 | 0.00 |
| November | 170.86 | 113.15 | 57.71 | 298.82 | 95.07 | 0.00 | 0.00 | 0.00 |
| December | 151.51 | 94.81 | 56.70 | 228.94 | 131.19 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 103.09 | 45.65 | 57.44 | 220.54 | 49.71 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 53.59 | 0.62 | 52.49 | 177.93 | 0.18 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 170.86 | 113.15 | 64.52 | 298.82 | 133.40 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW1 S S2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 141.32 | 85.53 | 55.78 | 205.04 | 133.36 | 0.00 | 0.00 | 0.00 |
| February | 136.39 | 76.29 | 60.10 | 214.96 | 108.21 | 0.00 | 0.00 | 0.00 |
| March | 112.65 | 48.13 | 64.52 | 211.96 | 62.69 | 0.00 | 0.00 | 0.00 |
| April | 83.64 | 25.35 | 58.30 | 218.49 | 17.45 | 0.00 | 0.00 | 0.00 |
| May | 58.63 | 4.55 | 54.08 | 210.40 | 1.40 | 0.00 | 0.00 | 0.00 |
| June | 53.59 | 1.09 | 52.49 | 209.07 | 1.44 | 0.00 | 0.00 | 0.00 |
| July | 55.56 | 0.62 | 54.94 | 195.66 | 0.18 | 0.00 | 0.00 | 0.00 |
| August | 58.38 | 2.45 | 55.93 | 177.93 | 0.55 | 0.00 | 0.00 | 0.00 |
| September | 81.86 | 23.19 | 58.66 | 199.44 | 3.66 | 0.00 | 0.00 | 0.00 |
| October | 135.20 | 75.02 | 60.18 | 276.24 | 44.22 | 0.00 | 0.00 | 0.00 |
| November | 170.86 | 113.15 | 57.71 | 298.75 | 95.03 | 0.00 | 0.00 | 0.00 |
| December | 151.51 | 94.81 | 56.70 | 228.82 | 131.15 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 103.09 | 45.65 | 57.44 | 220.49 | 49.69 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 53.59 | 0.62 | 52.49 | 177.93 | 0.18 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 170.86 | 113.15 | 64.52 | 298.75 | 133.36 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: TWINDOW14
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 10.60 | 4.28 | 6.33 | 11.56 | 21.61 | 474.17 | 0.00 | 0.00 |
| February | 12.84 | 5.28 | 7.55 | 16.98 | 17.81 | 390.50 | 0.00 | 0.00 |
| March | 15.67 | 6.46 | 9.21 | 26.06 | 10.81 | 387.67 | 0.00 | 0.00 |
| April | 18.70 | 8.74 | 9.97 | 40.07 | 3.71 | 249.00 | 0.00 | 0.00 |
| May | 18.35 | 8.14 | 10.21 | 45.86 | 0.59 | 73.83 | 0.00 | 0.00 |
| June | 14.93 | 4.95 | 9.98 | 41.14 | 0.53 | 49.00 | 0.00 | 0.00 |
| July | 12.53 | 2.63 | 9.90 | 33.64 | 0.11 | 9.67 | 0.00 | 0.00 |
| August | 11.30 | 1.96 | 9.35 | 27.91 | 0.44 | 67.50 | 0.00 | 0.00 |
| September | 12.05 | 3.34 | 8.71 | 26.00 | 1.64 | 214.67 | 0.00 | 0.00 |
| October | 13.23 | 5.35 | 7.88 | 25.53 | 8.32 | 389.33 | 0.00 | 0.00 |
| November | 11.70 | 5.01 | 6.69 | 17.93 | 15.88 | 419.33 | 0.00 | 0.00 |
| December | 10.20 | 4.04 | 6.16 | 12.01 | 21.50 | 469.67 | 0.00 | 0.00 |
| Annual Sum or Average | 13.51 | 5.01 | 8.50 | 27.09 | 8.54 | 3194.33 | 0.00 | 0.00 |
| Minimum of Months | 10.20 | 1.96 | 6.16 | 11.56 | 0.11 | 9.67 | 0.00 | 0.00 |
| Maximum of Months | 18.70 | 8.74 | 10.21 | 45.86 | 21.61 | 474.17 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ENTRANCE DOOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 31.58 | 12.74 | 18.85 | 31.58 | 69.19 | 3.17 | 0.00 | 0.00 |
| February | 38.23 | 15.74 | 22.49 | 48.89 | 55.84 | 5.33 | 0.00 | 0.00 |
| March | 46.68 | 19.25 | 27.44 | 75.94 | 34.67 | 6.17 | 0.00 | 0.00 |
| April | 55.71 | 26.02 | 29.69 | 114.25 | 14.35 | 0.83 | 0.00 | 0.00 |
| May | 54.65 | 24.23 | 30.42 | 127.51 | 4.01 | 30.00 | 0.00 | 0.00 |
| June | 44.46 | 14.75 | 29.71 | 112.26 | 3.10 | 57.83 | 0.00 | 0.00 |
| July | 37.32 | 7.84 | 29.48 | 90.20 | 1.39 | 92.17 | 0.00 | 0.00 |
| August | 33.66 | 5.83 | 27.83 | 75.30 | 3.49 | 178.33 | 0.00 | 0.00 |
| September | 35.90 | 9.95 | 25.95 | 71.44 | 9.53 | 170.17 | 0.00 | 0.00 |
| October | 39.40 | 15.93 | 23.47 | 71.25 | 30.41 | 40.50 | 0.00 | 0.00 |
| November | 34.84 | 14.92 | 19.92 | 49.73 | 52.81 | 15.83 | 0.00 | 0.00 |
| December | 30.37 | 12.02 | 18.35 | 31.59 | 71.07 | 7.33 | 0.00 | 0.00 |
| Annual Sum or Average | 40.22 | 14.91 | 25.31 | 75.08 | 29.04 | 607.67 | 0.00 | 0.00 |
| Minimum of Months | 30.37 | 5.83 | 18.35 | 31.58 | 1.39 | 0.83 | 0.00 | 0.00 |
| Maximum of Months | 55.71 | 26.02 | 30.42 | 127.51 | 71.07 | 178.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: MWINDOW14
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
| January | 10.60 | 4.28 | 6.33 | 9.62 | 24.79 | 614.17 | 0.00 | 0.00 |
| February | 12.84 | 5.28 | 7.55 | 15.66 | 19.76 | 456.50 | 0.00 | 0.00 |
| March | 15.67 | 6.46 | 9.21 | 25.67 | 11.41 | 413.83 | 0.00 | 0.00 |
| April | 18.70 | 8.74 | 9.97 | 40.60 | 3.87 | 245.00 | 0.00 | 0.00 |
| May | 18.35 | 8.14 | 10.21 | 46.96 | 0.60 | 70.17 | 0.00 | 0.00 |
| June | 14.93 | 4.95 | 9.98 | 42.41 | 0.51 | 46.83 | 0.00 | 0.00 |
| July | 12.53 | 2.63 | 9.90 | 34.85 | 0.10 | 8.00 | 0.00 | 0.00 |
| August | 11.30 | 1.96 | 9.35 | 28.87 | 0.41 | 55.17 | 0.00 | 0.00 |
| September | 12.05 | 3.34 | 8.71 | 26.56 | 1.62 | 200.17 | 0.00 | 0.00 |
| October | 13.23 | 5.35 | 7.88 | 25.45 | 8.72 | 397.83 | 0.00 | 0.00 |
| November | 11.70 | 5.01 | 6.69 | 17.04 | 17.15 | 468.00 | 0.00 | 0.00 |
| December | 10.20 | 4.04 | 6.16 | 10.15 | 24.64 | 594.83 | 0.00 | 0.00 |
| Annual Sum or Average | 13.51 | 5.01 | 8.50 | 27.03 | 9.42 | 3570.50 | 0.00 | 0.00 |
| Minimum of Months | 10.20 | 1.96 | 6.16 | 9.62 | 0.10 | 8.00 | 0.00 | 0.00 |
| Maximum of Months | 18.70 | 8.74 | 10.21 | 46.96 | 24.79 | 614.17 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.378498E+09 | 0.229085E+09 | 0.149413E+09 | 0.547448E+09 | 0.382614E+09 |
| February | 0.329963E+09 | 0.184565E+09 | 0.145398E+09 | 0.527347E+09 | 0.270614E+09 |
| March | 0.301718E+09 | 0.128904E+09 | 0.172815E+09 | 0.578502E+09 | 0.169533E+09 |
| April | 0.216806E+09 | 65697605.51 | 0.151109E+09 | 0.572970E+09 | 47963854.60 |
| May | 0.157039E+09 | 12190734.33 | 0.144848E+09 | 0.561595E+09 | 4579736.77 |
| June | 0.138893E+09 | 2831454.13 | 0.136062E+09 | 0.536712E+09 | 4401939.73 |
| July | 0.148818E+09 | 1657347.09 | 0.147161E+09 | 0.514026E+09 | 674746.58 |
| August | 0.156363E+09 | 6555053.33 | 0.149808E+09 | 0.466449E+09 | 2775141.82 |
| September | 0.212171E+09 | 60116108.52 | 0.152055E+09 | 0.510848E+09 | 15351652.61 |
| October | 0.362124E+09 | 0.200926E+09 | 0.161198E+09 | 0.739410E+09 | 0.132959E+09 |
| November | 0.442866E+09 | 0.293281E+09 | 0.149585E+09 | 0.775876E+09 | 0.262396E+09 |
| December | 0.405808E+09 | 0.253939E+09 | 0.151870E+09 | 0.608375E+09 | 0.379162E+09 |
| Annual Sum or Average | 0.325107E+10 | 0.143975E+10 | 0.181132E+10 | 0.693956E+10 | 0.167302E+10 |
| Minimum of Months | 0.138893E+09 | 1657347.09 | 0.136062E+09 | 0.466449E+09 | 674746.58 |
| Maximum of Months | 0.442866E+09 | 0.293281E+09 | 0.172815E+09 | 0.775876E+09 | 0.382614E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 W SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.115424E+09 | 44877482.19 | 70546591.29 | 0.129765E+09 | 0.275274E+09 |
| February | 0.119084E+09 | 43815973.67 | 75267809.98 | 0.165275E+09 | 0.188706E+09 |
| March | 0.171866E+09 | 69065691.27 | 0.102800E+09 | 0.308911E+09 | 0.113306E+09 |
| April | 0.201023E+09 | 94095700.36 | 0.106927E+09 | 0.464873E+09 | 30911727.65 |
| May | 0.196762E+09 | 83329964.89 | 0.113432E+09 | 0.544920E+09 | 3095161.46 |
| June | 0.179622E+09 | 70119107.14 | 0.109503E+09 | 0.526561E+09 | 2829253.34 |
| July | 0.137224E+09 | 26614336.26 | 0.110610E+09 | 0.412605E+09 | 478579.46 |
| August | 0.125827E+09 | 22084771.01 | 0.103743E+09 | 0.348229E+09 | 1864889.94 |
| September | 0.134501E+09 | 39798401.45 | 94702751.95 | 0.314169E+09 | 9985537.12 |
| October | 0.144267E+09 | 57399869.82 | 86866962.91 | 0.294170E+09 | 89524091.98 |
| November | 0.126283E+09 | 53795546.57 | 72487846.06 | 0.204453E+09 | 0.181705E+09 |
| December | 0.111808E+09 | 42700072.59 | 69107612.04 | 0.127314E+09 | 0.269010E+09 |
| Annual Sum or Average | 0.176369E+10 | 0.647697E+09 | 0.111599E+10 | 0.384124E+10 | 0.116669E+10 |
| Minimum of Months | 0.111808E+09 | 22084771.01 | 69107612.04 | 0.127314E+09 | 478579.46 |
| Maximum of Months | 0.201023E+09 | 94095700.36 | 0.113432E+09 | 0.544920E+09 | 0.275274E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 W NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.115424E+09 | 44877482.19 | 70546591.29 | 0.143920E+09 | 0.251657E+09 |
| February | 0.119084E+09 | 43815973.67 | 75267809.98 | 0.174568E+09 | 0.177262E+09 |
| March | 0.171866E+09 | 69065691.27 | 0.102800E+09 | 0.314366E+09 | 0.109341E+09 |
| April | 0.201023E+09 | 94095700.36 | 0.106927E+09 | 0.468108E+09 | 29865917.33 |
| May | 0.196762E+09 | 83329964.89 | 0.113432E+09 | 0.545651E+09 | 3068551.68 |
| June | 0.179622E+09 | 70119107.14 | 0.109503E+09 | 0.526394E+09 | 2829258.07 |
| July | 0.137224E+09 | 26614336.26 | 0.110610E+09 | 0.412525E+09 | 481536.86 |
| August | 0.125827E+09 | 22084771.01 | 0.103743E+09 | 0.348912E+09 | 1855482.42 |
| September | 0.134501E+09 | 39798401.45 | 94702751.95 | 0.316718E+09 | 9397046.79 |
| October | 0.144267E+09 | 57399869.82 | 86866962.91 | 0.299252E+09 | 86137963.91 |
| November | 0.126283E+09 | 53795546.57 | 72487846.06 | 0.211593E+09 | 0.175642E+09 |
| December | 0.111808E+09 | 42700072.59 | 69107612.04 | 0.136889E+09 | 0.257202E+09 |
| Annual Sum or Average | 0.176369E+10 | 0.647697E+09 | 0.111599E+10 | 0.389890E+10 | 0.110474E+10 |
| Minimum of Months | 0.111808E+09 | 22084771.01 | 69107612.04 | 0.136889E+09 | 481536.86 |
| Maximum of Months | 0.201023E+09 | 94095700.36 | 0.113432E+09 | 0.545651E+09 | 0.257202E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 83720776.50 | 0.00 | 83720776.50 | 48078040.59 | 0.394011E+09 |
| February | 89671001.12 | 0.00 | 89671001.12 | 88907675.91 | 0.274035E+09 |
| March | 0.119662E+09 | 11416.56 | 0.119651E+09 | 0.200972E+09 | 0.167415E+09 |
| April | 0.125924E+09 | 626385.41 | 0.125297E+09 | 0.358294E+09 | 44904635.47 |
| May | 0.144278E+09 | 4464536.23 | 0.139814E+09 | 0.525745E+09 | 4647103.58 |
| June | 0.143703E+09 | 4986643.04 | 0.138717E+09 | 0.545887E+09 | 4365319.44 |
| July | 0.147069E+09 | 2528891.87 | 0.144540E+09 | 0.507880E+09 | 687451.72 |
| August | 0.135248E+09 | 754189.90 | 0.134494E+09 | 0.419130E+09 | 2709598.61 |
| September | 0.116241E+09 | 14758.11 | 0.116226E+09 | 0.307486E+09 | 14310702.53 |
| October | 0.104047E+09 | 0.00 | 0.104047E+09 | 0.221494E+09 | 0.131622E+09 |
| November | 85286195.69 | 0.00 | 85286195.69 | 0.106866E+09 | 0.270562E+09 |
| December | 81671108.11 | 0.00 | 81671108.11 | 45899800.55 | 0.406068E+09 |
| Annual Sum or Average | 0.137652E+10 | 13386821.13 | 0.136313E+10 | 0.337664E+10 | 0.171534E+10 |
| Minimum of Months | 81671108.11 | 0.00 | 81671108.11 | 45899800.55 | 687451.72 |
| Maximum of Months | 0.147069E+09 | 4986643.04 | 0.144540E+09 | 0.545887E+09 | 0.406068E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.378498E+09 | 0.229085E+09 | 0.149413E+09 | 0.553258E+09 | 0.383220E+09 |
| February | 0.329963E+09 | 0.184565E+09 | 0.145398E+09 | 0.525200E+09 | 0.286170E+09 |
| March | 0.301718E+09 | 0.128904E+09 | 0.172815E+09 | 0.562085E+09 | 0.207564E+09 |
| April | 0.216806E+09 | 65697605.51 | 0.151109E+09 | 0.519865E+09 | 94598265.65 |
| May | 0.157039E+09 | 12190734.33 | 0.144848E+09 | 0.469732E+09 | 32844961.05 |
| June | 0.138893E+09 | 2831454.13 | 0.136062E+09 | 0.439436E+09 | 24405700.35 |
| July | 0.148818E+09 | 1657347.09 | 0.147161E+09 | 0.400648E+09 | 16286116.90 |
| August | 0.156363E+09 | 6555053.33 | 0.149808E+09 | 0.383709E+09 | 35076298.56 |
| September | 0.212171E+09 | 60116108.52 | 0.152055E+09 | 0.455218E+09 | 75836404.66 |
| October | 0.362124E+09 | 0.200926E+09 | 0.161198E+09 | 0.707513E+09 | 0.198548E+09 |
| November | 0.442866E+09 | 0.293281E+09 | 0.149585E+09 | 0.761279E+09 | 0.305196E+09 |
| December | 0.405808E+09 | 0.253939E+09 | 0.151870E+09 | 0.609731E+09 | 0.392260E+09 |
| Annual Sum or Average | 0.325107E+10 | 0.143975E+10 | 0.181132E+10 | 0.638767E+10 | 0.205201E+10 |
| Minimum of Months | 0.138893E+09 | 1657347.09 | 0.136062E+09 | 0.383709E+09 | 16286116.90 |
| Maximum of Months | 0.442866E+09 | 0.293281E+09 | 0.172815E+09 | 0.761279E+09 | 0.392260E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 E SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.118372E+09 | 47740397.38 | 70631611.97 | 0.119071E+09 | 0.255018E+09 |
| February | 0.129403E+09 | 53274837.78 | 76127870.07 | 0.169889E+09 | 0.185199E+09 |
| March | 0.174956E+09 | 72128237.55 | 0.102828E+09 | 0.296565E+09 | 0.130060E+09 |
| April | 0.202044E+09 | 94375988.81 | 0.107668E+09 | 0.428474E+09 | 59004173.97 |
| May | 0.204826E+09 | 90815308.18 | 0.114011E+09 | 0.498389E+09 | 20913207.93 |
| June | 0.161251E+09 | 53480275.79 | 0.107771E+09 | 0.426412E+09 | 15870773.16 |
| July | 0.139881E+09 | 29385658.23 | 0.110495E+09 | 0.344951E+09 | 10557752.33 |
| August | 0.126159E+09 | 21847583.13 | 0.104312E+09 | 0.293763E+09 | 22863548.70 |
| September | 0.130197E+09 | 36084523.85 | 94112532.07 | 0.267592E+09 | 48546773.58 |
| October | 0.147656E+09 | 59709845.47 | 87945784.03 | 0.274315E+09 | 0.127647E+09 |
| November | 0.126367E+09 | 54128288.04 | 72238413.64 | 0.182980E+09 | 0.198517E+09 |
| December | 0.113839E+09 | 45058622.97 | 68780520.62 | 0.120141E+09 | 0.264245E+09 |
| Annual Sum or Average | 0.177495E+10 | 0.658030E+09 | 0.111692E+10 | 0.342254E+10 | 0.133844E+10 |
| Minimum of Months | 0.113839E+09 | 21847583.13 | 68780520.62 | 0.119071E+09 | 10557752.33 |
| Maximum of Months | 0.204826E+09 | 94375988.81 | 0.114011E+09 | 0.498389E+09 | 0.264245E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 E NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.118372E+09 | 47740397.38 | 70631611.97 | 0.129591E+09 | 0.232186E+09 |
| February | 0.129403E+09 | 53274837.78 | 76127870.07 | 0.179130E+09 | 0.164133E+09 |
| March | 0.174956E+09 | 72128237.55 | 0.102828E+09 | 0.311684E+09 | 0.101589E+09 |
| April | 0.202044E+09 | 94375988.81 | 0.107668E+09 | 0.468024E+09 | 28487746.89 |
| May | 0.204826E+09 | 90815308.18 | 0.114011E+09 | 0.559829E+09 | 2887383.95 |
| June | 0.161251E+09 | 53480275.79 | 0.107771E+09 | 0.490584E+09 | 2808696.96 |
| July | 0.139881E+09 | 29385658.23 | 0.110495E+09 | 0.419869E+09 | 432257.23 |
| August | 0.126159E+09 | 21847583.13 | 0.104312E+09 | 0.348908E+09 | 1746935.56 |
| September | 0.130197E+09 | 36084523.85 | 94112532.07 | 0.307956E+09 | 9035556.07 |
| October | 0.147656E+09 | 59709845.47 | 87945784.03 | 0.299680E+09 | 81712831.88 |
| November | 0.126367E+09 | 54128288.04 | 72238413.64 | 0.197815E+09 | 0.163818E+09 |
| December | 0.113839E+09 | 45058622.97 | 68780520.62 | 0.127778E+09 | 0.243063E+09 |
| Annual Sum or Average | 0.177495E+10 | 0.658030E+09 | 0.111692E+10 | 0.384085E+10 | 0.103190E+10 |
| Minimum of Months | 0.113839E+09 | 21847583.13 | 68780520.62 | 0.127778E+09 | 432257.23 |
| Maximum of Months | 0.204826E+09 | 94375988.81 | 0.114011E+09 | 0.559829E+09 | 0.243063E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 83720776.50 | 0.00 | 83720776.50 | 46236982.04 | 0.393762E+09 |
| February | 89671001.12 | 0.00 | 89671001.12 | 86434525.30 | 0.274528E+09 |
| March | 0.119662E+09 | 11416.56 | 0.119651E+09 | 0.198556E+09 | 0.167124E+09 |
| April | 0.125924E+09 | 626385.41 | 0.125297E+09 | 0.357379E+09 | 44623778.59 |
| May | 0.144278E+09 | 4464536.23 | 0.139814E+09 | 0.525239E+09 | 4563596.26 |
| June | 0.143703E+09 | 4986643.04 | 0.138717E+09 | 0.546457E+09 | 4299338.33 |
| July | 0.147069E+09 | 2528891.87 | 0.144540E+09 | 0.507817E+09 | 686634.87 |
| August | 0.135248E+09 | 754189.90 | 0.134494E+09 | 0.419054E+09 | 2717706.36 |
| September | 0.116241E+09 | 14758.11 | 0.116226E+09 | 0.307465E+09 | 14115341.22 |
| October | 0.104047E+09 | 0.00 | 0.104047E+09 | 0.220412E+09 | 0.131281E+09 |
| November | 85286195.69 | 0.00 | 85286195.69 | 0.105081E+09 | 0.269950E+09 |
| December | 81671108.11 | 0.00 | 81671108.11 | 44270178.26 | 0.405249E+09 |
| Annual Sum or Average | 0.137652E+10 | 13386821.13 | 0.136313E+10 | 0.336440E+10 | 0.171290E+10 |
| Minimum of Months | 81671108.11 | 0.00 | 81671108.11 | 44270178.26 | 686634.87 |
| Maximum of Months | 0.147069E+09 | 4986643.04 | 0.144540E+09 | 0.546457E+09 | 0.405249E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N N1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 83720776.50 | 0.00 | 83720776.50 | 44092343.56 | 0.410391E+09 |
| February | 89671001.12 | 0.00 | 89671001.12 | 86136546.68 | 0.283458E+09 |
| March | 0.119662E+09 | 11416.56 | 0.119651E+09 | 0.201257E+09 | 0.169355E+09 |
| April | 0.125924E+09 | 626385.41 | 0.125297E+09 | 0.364007E+09 | 44380407.81 |
| May | 0.144278E+09 | 4464536.23 | 0.139814E+09 | 0.535867E+09 | 4281845.17 |
| June | 0.143703E+09 | 4986643.04 | 0.138717E+09 | 0.557154E+09 | 4073757.44 |
| July | 0.147069E+09 | 2528891.87 | 0.144540E+09 | 0.519014E+09 | 616544.47 |
| August | 0.135248E+09 | 754189.90 | 0.134494E+09 | 0.429361E+09 | 2201623.83 |
| September | 0.116241E+09 | 14758.11 | 0.116226E+09 | 0.315520E+09 | 12318374.68 |
| October | 0.104047E+09 | 0.00 | 0.104047E+09 | 0.225864E+09 | 0.129000E+09 |
| November | 85286195.69 | 0.00 | 85286195.69 | 0.107936E+09 | 0.270408E+09 |
| December | 81671108.11 | 0.00 | 81671108.11 | 44343569.13 | 0.413186E+09 |
| Annual Sum or Average | 0.137652E+10 | 13386821.13 | 0.136313E+10 | 0.343055E+10 | 0.174367E+10 |
| Minimum of Months | 81671108.11 | 0.00 | 81671108.11 | 44092343.56 | 616544.47 |
| Maximum of Months | 0.147069E+09 | 4986643.04 | 0.144540E+09 | 0.557154E+09 | 0.413186E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 N N2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 83720776.50 | 0.00 | 83720776.50 | 43976376.29 | 0.410493E+09 |
| February | 89671001.12 | 0.00 | 89671001.12 | 85967963.45 | 0.283627E+09 |
| March | 0.119662E+09 | 11416.56 | 0.119651E+09 | 0.201134E+09 | 0.169390E+09 |
| April | 0.125924E+09 | 626385.41 | 0.125297E+09 | 0.363965E+09 | 44377014.30 |
| May | 0.144278E+09 | 4464536.23 | 0.139814E+09 | 0.535845E+09 | 4279275.77 |
| June | 0.143703E+09 | 4986643.04 | 0.138717E+09 | 0.557177E+09 | 4070971.61 |
| July | 0.147069E+09 | 2528891.87 | 0.144540E+09 | 0.519011E+09 | 616448.01 |
| August | 0.135248E+09 | 754189.90 | 0.134494E+09 | 0.429357E+09 | 2202183.30 |
| September | 0.116241E+09 | 14758.11 | 0.116226E+09 | 0.315520E+09 | 12311242.74 |
| October | 0.104047E+09 | 0.00 | 0.104047E+09 | 0.225821E+09 | 0.128999E+09 |
| November | 85286195.69 | 0.00 | 85286195.69 | 0.107851E+09 | 0.270422E+09 |
| December | 81671108.11 | 0.00 | 81671108.11 | 44262195.80 | 0.413211E+09 |
| Annual Sum or Average | 0.137652E+10 | 13386821.13 | 0.136313E+10 | 0.342989E+10 | 0.174400E+10 |
| Minimum of Months | 81671108.11 | 0.00 | 81671108.11 | 43976376.29 | 616448.01 |
| Maximum of Months | 0.147069E+09 | 4986643.04 | 0.144540E+09 | 0.557177E+09 | 0.413211E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S S1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.378498E+09 | 0.229085E+09 | 0.149413E+09 | 0.542540E+09 | 0.392361E+09 |
| February | 0.329963E+09 | 0.184565E+09 | 0.145398E+09 | 0.524533E+09 | 0.276360E+09 |
| March | 0.301718E+09 | 0.128904E+09 | 0.172815E+09 | 0.578066E+09 | 0.171634E+09 |
| April | 0.216806E+09 | 65697605.51 | 0.151109E+09 | 0.577973E+09 | 47592517.88 |
| May | 0.157039E+09 | 12190734.33 | 0.144848E+09 | 0.571412E+09 | 4256705.13 |
| June | 0.138893E+09 | 2831454.13 | 0.136062E+09 | 0.547817E+09 | 4110979.56 |
| July | 0.148818E+09 | 1657347.09 | 0.147161E+09 | 0.525063E+09 | 617439.42 |
| August | 0.156363E+09 | 6555053.33 | 0.149808E+09 | 0.476384E+09 | 2293547.29 |
| September | 0.212171E+09 | 60116108.52 | 0.152055E+09 | 0.518211E+09 | 13431179.45 |
| October | 0.362124E+09 | 0.200926E+09 | 0.161198E+09 | 0.742913E+09 | 0.130892E+09 |
| November | 0.442866E+09 | 0.293281E+09 | 0.149585E+09 | 0.776022E+09 | 0.263183E+09 |
| December | 0.405808E+09 | 0.253939E+09 | 0.151870E+09 | 0.605862E+09 | 0.384221E+09 |
| Annual Sum or Average | 0.325107E+10 | 0.143975E+10 | 0.181132E+10 | 0.698680E+10 | 0.169095E+10 |
| Minimum of Months | 0.138893E+09 | 1657347.09 | 0.136062E+09 | 0.476384E+09 | 617439.42 |
| Maximum of Months | 0.442866E+09 | 0.293281E+09 | 0.172815E+09 | 0.776022E+09 | 0.392361E+09 |
Report: WindowEnergyReportMonthly
For: GWINDOW1 S S2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.378498E+09 | 0.229085E+09 | 0.149413E+09 | 0.542794E+09 | 0.391773E+09 |
| February | 0.329963E+09 | 0.184565E+09 | 0.145398E+09 | 0.524106E+09 | 0.276913E+09 |
| March | 0.301718E+09 | 0.128904E+09 | 0.172815E+09 | 0.576780E+09 | 0.173206E+09 |
| April | 0.216806E+09 | 65697605.51 | 0.151109E+09 | 0.575361E+09 | 49187300.08 |
| May | 0.157039E+09 | 12190734.33 | 0.144848E+09 | 0.567123E+09 | 4643933.66 |
| June | 0.138893E+09 | 2831454.13 | 0.136062E+09 | 0.543680E+09 | 4426386.44 |
| July | 0.148818E+09 | 1657347.09 | 0.147161E+09 | 0.520366E+09 | 675281.12 |
| August | 0.156363E+09 | 6555053.33 | 0.149808E+09 | 0.472331E+09 | 2666058.33 |
| September | 0.212171E+09 | 60116108.52 | 0.152055E+09 | 0.515133E+09 | 14839396.04 |
| October | 0.362124E+09 | 0.200926E+09 | 0.161198E+09 | 0.740970E+09 | 0.133470E+09 |
| November | 0.442866E+09 | 0.293281E+09 | 0.149585E+09 | 0.774840E+09 | 0.264988E+09 |
| December | 0.405808E+09 | 0.253939E+09 | 0.151870E+09 | 0.605592E+09 | 0.384501E+09 |
| Annual Sum or Average | 0.325107E+10 | 0.143975E+10 | 0.181132E+10 | 0.695908E+10 | 0.170129E+10 |
| Minimum of Months | 0.138893E+09 | 1657347.09 | 0.136062E+09 | 0.472331E+09 | 675281.12 |
| Maximum of Months | 0.442866E+09 | 0.293281E+09 | 0.172815E+09 | 0.774840E+09 | 0.391773E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.378498E+09 | 0.229085E+09 | 0.149413E+09 | 0.540740E+09 | 0.388116E+09 |
| February | 0.329963E+09 | 0.184565E+09 | 0.145398E+09 | 0.519690E+09 | 0.278063E+09 |
| March | 0.301718E+09 | 0.128904E+09 | 0.172815E+09 | 0.571406E+09 | 0.174886E+09 |
| April | 0.216806E+09 | 65697605.51 | 0.151109E+09 | 0.570604E+09 | 48669716.65 |
| May | 0.157039E+09 | 12190734.33 | 0.144848E+09 | 0.566645E+09 | 4280551.26 |
| June | 0.138893E+09 | 2831454.13 | 0.136062E+09 | 0.545767E+09 | 3898538.58 |
| July | 0.148818E+09 | 1657347.09 | 0.147161E+09 | 0.528422E+09 | 515208.86 |
| August | 0.156363E+09 | 6555053.33 | 0.149808E+09 | 0.481128E+09 | 1622664.82 |
| September | 0.212171E+09 | 60116108.52 | 0.152055E+09 | 0.521445E+09 | 10682025.15 |
| October | 0.362124E+09 | 0.200926E+09 | 0.161198E+09 | 0.744495E+09 | 0.124128E+09 |
| November | 0.442866E+09 | 0.293281E+09 | 0.149585E+09 | 0.776967E+09 | 0.256655E+09 |
| December | 0.405808E+09 | 0.253939E+09 | 0.151870E+09 | 0.606417E+09 | 0.377419E+09 |
| Annual Sum or Average | 0.325107E+10 | 0.143975E+10 | 0.181132E+10 | 0.697373E+10 | 0.166894E+10 |
| Minimum of Months | 0.138893E+09 | 1657347.09 | 0.136062E+09 | 0.481128E+09 | 515208.86 |
| Maximum of Months | 0.442866E+09 | 0.293281E+09 | 0.172815E+09 | 0.776967E+09 | 0.388116E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 W SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.115424E+09 | 44877482.19 | 70546591.29 | 0.126515E+09 | 0.279536E+09 |
| February | 0.119084E+09 | 43815973.67 | 75267809.98 | 0.161249E+09 | 0.194031E+09 |
| March | 0.171866E+09 | 69065691.27 | 0.102800E+09 | 0.304702E+09 | 0.117063E+09 |
| April | 0.201023E+09 | 94095700.36 | 0.106927E+09 | 0.463422E+09 | 31355788.16 |
| May | 0.196762E+09 | 83329964.89 | 0.113432E+09 | 0.547781E+09 | 2905833.57 |
| June | 0.179622E+09 | 70119107.14 | 0.109503E+09 | 0.531950E+09 | 2522823.05 |
| July | 0.137224E+09 | 26614336.26 | 0.110610E+09 | 0.421292E+09 | 359229.45 |
| August | 0.125827E+09 | 22084771.01 | 0.103743E+09 | 0.357732E+09 | 1086426.39 |
| September | 0.134501E+09 | 39798401.45 | 94702751.95 | 0.321447E+09 | 6941827.72 |
| October | 0.144267E+09 | 57399869.82 | 86866962.91 | 0.298127E+09 | 83551695.96 |
| November | 0.126283E+09 | 53795546.57 | 72487846.06 | 0.205881E+09 | 0.177732E+09 |
| December | 0.111808E+09 | 42700072.59 | 69107612.04 | 0.126672E+09 | 0.267869E+09 |
| Annual Sum or Average | 0.176369E+10 | 0.647697E+09 | 0.111599E+10 | 0.386677E+10 | 0.116496E+10 |
| Minimum of Months | 0.111808E+09 | 22084771.01 | 69107612.04 | 0.126515E+09 | 359229.45 |
| Maximum of Months | 0.201023E+09 | 94095700.36 | 0.113432E+09 | 0.547781E+09 | 0.279536E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 W NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.115424E+09 | 44877482.19 | 70546591.29 | 0.140767E+09 | 0.258046E+09 |
| February | 0.119084E+09 | 43815973.67 | 75267809.98 | 0.169034E+09 | 0.186804E+09 |
| March | 0.171866E+09 | 69065691.27 | 0.102800E+09 | 0.309202E+09 | 0.114533E+09 |
| April | 0.201023E+09 | 94095700.36 | 0.106927E+09 | 0.466133E+09 | 30636098.95 |
| May | 0.196762E+09 | 83329964.89 | 0.113432E+09 | 0.548434E+09 | 2883455.66 |
| June | 0.179622E+09 | 70119107.14 | 0.109503E+09 | 0.531879E+09 | 2513321.88 |
| July | 0.137224E+09 | 26614336.26 | 0.110610E+09 | 0.421320E+09 | 360695.77 |
| August | 0.125827E+09 | 22084771.01 | 0.103743E+09 | 0.358420E+09 | 1074233.35 |
| September | 0.134501E+09 | 39798401.45 | 94702751.95 | 0.323956E+09 | 6563236.11 |
| October | 0.144267E+09 | 57399869.82 | 86866962.91 | 0.303091E+09 | 80842319.11 |
| November | 0.126283E+09 | 53795546.57 | 72487846.06 | 0.213318E+09 | 0.172228E+09 |
| December | 0.111808E+09 | 42700072.59 | 69107612.04 | 0.137982E+09 | 0.254060E+09 |
| Annual Sum or Average | 0.176369E+10 | 0.647697E+09 | 0.111599E+10 | 0.392354E+10 | 0.111054E+10 |
| Minimum of Months | 0.111808E+09 | 22084771.01 | 69107612.04 | 0.137982E+09 | 360695.77 |
| Maximum of Months | 0.201023E+09 | 94095700.36 | 0.113432E+09 | 0.548434E+09 | 0.258046E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 83720776.50 | 0.00 | 83720776.50 | 45262194.88 | 0.404090E+09 |
| February | 89671001.12 | 0.00 | 89671001.12 | 82622391.17 | 0.289139E+09 |
| March | 0.119662E+09 | 11416.56 | 0.119651E+09 | 0.194771E+09 | 0.175249E+09 |
| April | 0.125924E+09 | 626385.41 | 0.125297E+09 | 0.357015E+09 | 45980840.36 |
| May | 0.144278E+09 | 4464536.23 | 0.139814E+09 | 0.530965E+09 | 4354840.37 |
| June | 0.143703E+09 | 4986643.04 | 0.138717E+09 | 0.555119E+09 | 3858947.03 |
| July | 0.147069E+09 | 2528891.87 | 0.144540E+09 | 0.522041E+09 | 510360.73 |
| August | 0.135248E+09 | 754189.90 | 0.134494E+09 | 0.434173E+09 | 1565163.80 |
| September | 0.116241E+09 | 14758.11 | 0.116226E+09 | 0.319649E+09 | 9921068.96 |
| October | 0.104047E+09 | 0.00 | 0.104047E+09 | 0.228549E+09 | 0.123328E+09 |
| November | 85286195.69 | 0.00 | 85286195.69 | 0.110432E+09 | 0.264740E+09 |
| December | 81671108.11 | 0.00 | 81671108.11 | 47882158.23 | 0.400321E+09 |
| Annual Sum or Average | 0.137652E+10 | 13386821.13 | 0.136313E+10 | 0.342848E+10 | 0.172306E+10 |
| Minimum of Months | 81671108.11 | 0.00 | 81671108.11 | 45262194.88 | 510360.73 |
| Maximum of Months | 0.147069E+09 | 4986643.04 | 0.144540E+09 | 0.555119E+09 | 0.404090E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.378498E+09 | 0.229085E+09 | 0.149413E+09 | 0.538767E+09 | 0.387049E+09 |
| February | 0.329963E+09 | 0.184565E+09 | 0.145398E+09 | 0.517125E+09 | 0.277550E+09 |
| March | 0.301718E+09 | 0.128904E+09 | 0.172815E+09 | 0.568782E+09 | 0.174372E+09 |
| April | 0.216806E+09 | 65697605.51 | 0.151109E+09 | 0.569734E+09 | 48321217.66 |
| May | 0.157039E+09 | 12190734.33 | 0.144848E+09 | 0.566193E+09 | 4199496.12 |
| June | 0.138893E+09 | 2831454.13 | 0.136062E+09 | 0.546256E+09 | 3839881.71 |
| July | 0.148818E+09 | 1657347.09 | 0.147161E+09 | 0.528364E+09 | 514701.97 |
| August | 0.156363E+09 | 6555053.33 | 0.149808E+09 | 0.481067E+09 | 1627078.26 |
| September | 0.212171E+09 | 60116108.52 | 0.152055E+09 | 0.521420E+09 | 10517482.55 |
| October | 0.362124E+09 | 0.200926E+09 | 0.161198E+09 | 0.743329E+09 | 0.123656E+09 |
| November | 0.442866E+09 | 0.293281E+09 | 0.149585E+09 | 0.774937E+09 | 0.255869E+09 |
| December | 0.405808E+09 | 0.253939E+09 | 0.151870E+09 | 0.604316E+09 | 0.376620E+09 |
| Annual Sum or Average | 0.325107E+10 | 0.143975E+10 | 0.181132E+10 | 0.696029E+10 | 0.166414E+10 |
| Minimum of Months | 0.138893E+09 | 1657347.09 | 0.136062E+09 | 0.481067E+09 | 514701.97 |
| Maximum of Months | 0.442866E+09 | 0.293281E+09 | 0.172815E+09 | 0.774937E+09 | 0.387049E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 E SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.118372E+09 | 47740397.38 | 70631611.97 | 0.112033E+09 | 0.258523E+09 |
| February | 0.129403E+09 | 53274837.78 | 76127870.07 | 0.165614E+09 | 0.179610E+09 |
| March | 0.174956E+09 | 72128237.55 | 0.102828E+09 | 0.301510E+09 | 0.108423E+09 |
| April | 0.202044E+09 | 94375988.81 | 0.107668E+09 | 0.463245E+09 | 29825041.13 |
| May | 0.204826E+09 | 90815308.18 | 0.114011E+09 | 0.561568E+09 | 2714499.62 |
| June | 0.161251E+09 | 53480275.79 | 0.107771E+09 | 0.496050E+09 | 2494133.89 |
| July | 0.139881E+09 | 29385658.23 | 0.110495E+09 | 0.429098E+09 | 331031.54 |
| August | 0.126159E+09 | 21847583.13 | 0.104312E+09 | 0.357678E+09 | 1029416.16 |
| September | 0.130197E+09 | 36084523.85 | 94112532.07 | 0.312883E+09 | 6704724.28 |
| October | 0.147656E+09 | 59709845.47 | 87945784.03 | 0.299018E+09 | 79353356.58 |
| November | 0.126367E+09 | 54128288.04 | 72238413.64 | 0.192509E+09 | 0.166067E+09 |
| December | 0.113839E+09 | 45058622.97 | 68780520.62 | 0.118633E+09 | 0.254490E+09 |
| Annual Sum or Average | 0.177495E+10 | 0.658030E+09 | 0.111692E+10 | 0.380984E+10 | 0.108957E+10 |
| Minimum of Months | 0.113839E+09 | 21847583.13 | 68780520.62 | 0.112033E+09 | 331031.54 |
| Maximum of Months | 0.204826E+09 | 94375988.81 | 0.114011E+09 | 0.561568E+09 | 0.258523E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 E NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.118372E+09 | 47740397.38 | 70631611.97 | 0.126127E+09 | 0.238108E+09 |
| February | 0.129403E+09 | 53274837.78 | 76127870.07 | 0.173090E+09 | 0.172675E+09 |
| March | 0.174956E+09 | 72128237.55 | 0.102828E+09 | 0.305882E+09 | 0.106113E+09 |
| April | 0.202044E+09 | 94375988.81 | 0.107668E+09 | 0.465962E+09 | 29155038.83 |
| May | 0.204826E+09 | 90815308.18 | 0.114011E+09 | 0.562248E+09 | 2694182.96 |
| June | 0.161251E+09 | 53480275.79 | 0.107771E+09 | 0.495989E+09 | 2484752.16 |
| July | 0.139881E+09 | 29385658.23 | 0.110495E+09 | 0.429132E+09 | 332705.27 |
| August | 0.126159E+09 | 21847583.13 | 0.104312E+09 | 0.358372E+09 | 1017355.38 |
| September | 0.130197E+09 | 36084523.85 | 94112532.07 | 0.315409E+09 | 6331486.65 |
| October | 0.147656E+09 | 59709845.47 | 87945784.03 | 0.303998E+09 | 76862177.48 |
| November | 0.126367E+09 | 54128288.04 | 72238413.64 | 0.199935E+09 | 0.160300E+09 |
| December | 0.113839E+09 | 45058622.97 | 68780520.62 | 0.129021E+09 | 0.240139E+09 |
| Annual Sum or Average | 0.177495E+10 | 0.658030E+09 | 0.111692E+10 | 0.386517E+10 | 0.103621E+10 |
| Minimum of Months | 0.113839E+09 | 21847583.13 | 68780520.62 | 0.126127E+09 | 332705.27 |
| Maximum of Months | 0.204826E+09 | 94375988.81 | 0.114011E+09 | 0.562248E+09 | 0.240139E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 83720776.50 | 0.00 | 83720776.50 | 43054436.19 | 0.403815E+09 |
| February | 89671001.12 | 0.00 | 89671001.12 | 79907824.95 | 0.289083E+09 |
| March | 0.119662E+09 | 11416.56 | 0.119651E+09 | 0.191944E+09 | 0.174939E+09 |
| April | 0.125924E+09 | 626385.41 | 0.125297E+09 | 0.356056E+09 | 45666961.23 |
| May | 0.144278E+09 | 4464536.23 | 0.139814E+09 | 0.530499E+09 | 4270291.56 |
| June | 0.143703E+09 | 4986643.04 | 0.138717E+09 | 0.555604E+09 | 3800313.35 |
| July | 0.147069E+09 | 2528891.87 | 0.144540E+09 | 0.521981E+09 | 509900.54 |
| August | 0.135248E+09 | 754189.90 | 0.134494E+09 | 0.434094E+09 | 1569216.62 |
| September | 0.116241E+09 | 14758.11 | 0.116226E+09 | 0.319627E+09 | 9765338.00 |
| October | 0.104047E+09 | 0.00 | 0.104047E+09 | 0.227237E+09 | 0.122949E+09 |
| November | 85286195.69 | 0.00 | 85286195.69 | 0.108309E+09 | 0.263597E+09 |
| December | 81671108.11 | 0.00 | 81671108.11 | 45813873.01 | 0.399506E+09 |
| Annual Sum or Average | 0.137652E+10 | 13386821.13 | 0.136313E+10 | 0.341413E+10 | 0.171947E+10 |
| Minimum of Months | 81671108.11 | 0.00 | 81671108.11 | 43054436.19 | 509900.54 |
| Maximum of Months | 0.147069E+09 | 4986643.04 | 0.144540E+09 | 0.555604E+09 | 0.403815E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N N1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 83720776.50 | 0.00 | 83720776.50 | 40391471.20 | 0.423002E+09 |
| February | 89671001.12 | 0.00 | 89671001.12 | 81362766.14 | 0.294383E+09 |
| March | 0.119662E+09 | 11416.56 | 0.119651E+09 | 0.196994E+09 | 0.174595E+09 |
| April | 0.125924E+09 | 626385.41 | 0.125297E+09 | 0.364492E+09 | 44588672.66 |
| May | 0.144278E+09 | 4464536.23 | 0.139814E+09 | 0.542042E+09 | 3943382.98 |
| June | 0.143703E+09 | 4986643.04 | 0.138717E+09 | 0.565965E+09 | 3615719.11 |
| July | 0.147069E+09 | 2528891.87 | 0.144540E+09 | 0.531232E+09 | 500450.15 |
| August | 0.135248E+09 | 754189.90 | 0.134494E+09 | 0.441843E+09 | 1404123.15 |
| September | 0.116241E+09 | 14758.11 | 0.116226E+09 | 0.325795E+09 | 9154602.57 |
| October | 0.104047E+09 | 0.00 | 0.104047E+09 | 0.231706E+09 | 0.122377E+09 |
| November | 85286195.69 | 0.00 | 85286195.69 | 0.110757E+09 | 0.265279E+09 |
| December | 81671108.11 | 0.00 | 81671108.11 | 44779944.41 | 0.412243E+09 |
| Annual Sum or Average | 0.137652E+10 | 13386821.13 | 0.136313E+10 | 0.347736E+10 | 0.175509E+10 |
| Minimum of Months | 81671108.11 | 0.00 | 81671108.11 | 40391471.20 | 500450.15 |
| Maximum of Months | 0.147069E+09 | 4986643.04 | 0.144540E+09 | 0.565965E+09 | 0.423002E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 N N2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 83720776.50 | 0.00 | 83720776.50 | 40249076.44 | 0.423120E+09 |
| February | 89671001.12 | 0.00 | 89671001.12 | 81200321.82 | 0.294487E+09 |
| March | 0.119662E+09 | 11416.56 | 0.119651E+09 | 0.196853E+09 | 0.174629E+09 |
| April | 0.125924E+09 | 626385.41 | 0.125297E+09 | 0.364452E+09 | 44581996.11 |
| May | 0.144278E+09 | 4464536.23 | 0.139814E+09 | 0.542024E+09 | 3940531.96 |
| June | 0.143703E+09 | 4986643.04 | 0.138717E+09 | 0.565982E+09 | 3613370.98 |
| July | 0.147069E+09 | 2528891.87 | 0.144540E+09 | 0.531229E+09 | 500397.59 |
| August | 0.135248E+09 | 754189.90 | 0.134494E+09 | 0.441839E+09 | 1404449.60 |
| September | 0.116241E+09 | 14758.11 | 0.116226E+09 | 0.325794E+09 | 9148684.93 |
| October | 0.104047E+09 | 0.00 | 0.104047E+09 | 0.231655E+09 | 0.122373E+09 |
| November | 85286195.69 | 0.00 | 85286195.69 | 0.110662E+09 | 0.265269E+09 |
| December | 81671108.11 | 0.00 | 81671108.11 | 44670146.43 | 0.412300E+09 |
| Annual Sum or Average | 0.137652E+10 | 13386821.13 | 0.136313E+10 | 0.347661E+10 | 0.175537E+10 |
| Minimum of Months | 81671108.11 | 0.00 | 81671108.11 | 40249076.44 | 500397.59 |
| Maximum of Months | 0.147069E+09 | 4986643.04 | 0.144540E+09 | 0.565982E+09 | 0.423120E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S S1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.378498E+09 | 0.229085E+09 | 0.149413E+09 | 0.536119E+09 | 0.397090E+09 |
| February | 0.329963E+09 | 0.184565E+09 | 0.145398E+09 | 0.518296E+09 | 0.281481E+09 |
| March | 0.301718E+09 | 0.128904E+09 | 0.172815E+09 | 0.572999E+09 | 0.174594E+09 |
| April | 0.216806E+09 | 65697605.51 | 0.151109E+09 | 0.577411E+09 | 47293770.03 |
| May | 0.157039E+09 | 12190734.33 | 0.144848E+09 | 0.577590E+09 | 3876255.82 |
| June | 0.138893E+09 | 2831454.13 | 0.136062E+09 | 0.556626E+09 | 3652855.89 |
| July | 0.148818E+09 | 1657347.09 | 0.147161E+09 | 0.537685E+09 | 504490.56 |
| August | 0.156363E+09 | 6555053.33 | 0.149808E+09 | 0.488653E+09 | 1445470.43 |
| September | 0.212171E+09 | 60116108.52 | 0.152055E+09 | 0.527130E+09 | 9920087.76 |
| October | 0.362124E+09 | 0.200926E+09 | 0.161198E+09 | 0.746957E+09 | 0.123424E+09 |
| November | 0.442866E+09 | 0.293281E+09 | 0.149585E+09 | 0.776475E+09 | 0.258241E+09 |
| December | 0.405808E+09 | 0.253939E+09 | 0.151870E+09 | 0.603194E+09 | 0.383190E+09 |
| Annual Sum or Average | 0.325107E+10 | 0.143975E+10 | 0.181132E+10 | 0.701914E+10 | 0.168471E+10 |
| Minimum of Months | 0.138893E+09 | 1657347.09 | 0.136062E+09 | 0.488653E+09 | 504490.56 |
| Maximum of Months | 0.442866E+09 | 0.293281E+09 | 0.172815E+09 | 0.776475E+09 | 0.397090E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW1 S S2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.378498E+09 | 0.229085E+09 | 0.149413E+09 | 0.536030E+09 | 0.397078E+09 |
| February | 0.329963E+09 | 0.184565E+09 | 0.145398E+09 | 0.518180E+09 | 0.281502E+09 |
| March | 0.301718E+09 | 0.128904E+09 | 0.172815E+09 | 0.572892E+09 | 0.174603E+09 |
| April | 0.216806E+09 | 65697605.51 | 0.151109E+09 | 0.577377E+09 | 47285062.82 |
| May | 0.157039E+09 | 12190734.33 | 0.144848E+09 | 0.577573E+09 | 3873388.19 |
| June | 0.138893E+09 | 2831454.13 | 0.136062E+09 | 0.556643E+09 | 3650459.74 |
| July | 0.148818E+09 | 1657347.09 | 0.147161E+09 | 0.537683E+09 | 504435.91 |
| August | 0.156363E+09 | 6555053.33 | 0.149808E+09 | 0.488650E+09 | 1445807.66 |
| September | 0.212171E+09 | 60116108.52 | 0.152055E+09 | 0.527130E+09 | 9914082.49 |
| October | 0.362124E+09 | 0.200926E+09 | 0.161198E+09 | 0.746921E+09 | 0.123414E+09 |
| November | 0.442866E+09 | 0.293281E+09 | 0.149585E+09 | 0.776402E+09 | 0.258231E+09 |
| December | 0.405808E+09 | 0.253939E+09 | 0.151870E+09 | 0.603104E+09 | 0.383188E+09 |
| Annual Sum or Average | 0.325107E+10 | 0.143975E+10 | 0.181132E+10 | 0.701858E+10 | 0.168469E+10 |
| Minimum of Months | 0.138893E+09 | 1657347.09 | 0.136062E+09 | 0.488650E+09 | 504435.91 |
| Maximum of Months | 0.442866E+09 | 0.293281E+09 | 0.172815E+09 | 0.776402E+09 | 0.397078E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.378498E+09 | 0.229085E+09 | 0.149413E+09 | 0.555519E+09 | 0.343392E+09 |
| February | 0.329963E+09 | 0.184565E+09 | 0.145398E+09 | 0.524176E+09 | 0.253006E+09 |
| March | 0.301718E+09 | 0.128904E+09 | 0.172815E+09 | 0.566206E+09 | 0.166340E+09 |
| April | 0.216806E+09 | 65697605.51 | 0.151109E+09 | 0.557807E+09 | 45828081.97 |
| May | 0.157039E+09 | 12190734.33 | 0.144848E+09 | 0.550708E+09 | 3985764.46 |
| June | 0.138893E+09 | 2831454.13 | 0.136062E+09 | 0.529132E+09 | 3860478.76 |
| July | 0.148818E+09 | 1657347.09 | 0.147161E+09 | 0.513288E+09 | 484075.39 |
| August | 0.156363E+09 | 6555053.33 | 0.149808E+09 | 0.467763E+09 | 1572292.63 |
| September | 0.212171E+09 | 60116108.52 | 0.152055E+09 | 0.510016E+09 | 9938693.87 |
| October | 0.362124E+09 | 0.200926E+09 | 0.161198E+09 | 0.736708E+09 | 0.118046E+09 |
| November | 0.442866E+09 | 0.293281E+09 | 0.149585E+09 | 0.776507E+09 | 0.240649E+09 |
| December | 0.405808E+09 | 0.253939E+09 | 0.151870E+09 | 0.620088E+09 | 0.337433E+09 |
| Annual Sum or Average | 0.325107E+10 | 0.143975E+10 | 0.181132E+10 | 0.690792E+10 | 0.152454E+10 |
| Minimum of Months | 0.138893E+09 | 1657347.09 | 0.136062E+09 | 0.467763E+09 | 484075.39 |
| Maximum of Months | 0.442866E+09 | 0.293281E+09 | 0.172815E+09 | 0.776507E+09 | 0.343392E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 W SWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.115424E+09 | 44877482.19 | 70546591.29 | 0.129241E+09 | 0.243237E+09 |
| February | 0.119084E+09 | 43815973.67 | 75267809.98 | 0.160772E+09 | 0.174247E+09 |
| March | 0.171866E+09 | 69065691.27 | 0.102800E+09 | 0.300115E+09 | 0.110493E+09 |
| April | 0.201023E+09 | 94095700.36 | 0.106927E+09 | 0.454602E+09 | 29367957.04 |
| May | 0.196762E+09 | 83329964.89 | 0.113432E+09 | 0.536996E+09 | 2712154.71 |
| June | 0.179622E+09 | 70119107.14 | 0.109503E+09 | 0.520768E+09 | 2471838.32 |
| July | 0.137224E+09 | 26614336.26 | 0.110610E+09 | 0.411040E+09 | 337085.06 |
| August | 0.125827E+09 | 22084771.01 | 0.103743E+09 | 0.348679E+09 | 1053472.19 |
| September | 0.134501E+09 | 39798401.45 | 94702751.95 | 0.313842E+09 | 6431414.41 |
| October | 0.144267E+09 | 57399869.82 | 86866962.91 | 0.292267E+09 | 78970190.80 |
| November | 0.126283E+09 | 53795546.57 | 72487846.06 | 0.203169E+09 | 0.164957E+09 |
| December | 0.111808E+09 | 42700072.59 | 69107612.04 | 0.129068E+09 | 0.235087E+09 |
| Annual Sum or Average | 0.176369E+10 | 0.647697E+09 | 0.111599E+10 | 0.380056E+10 | 0.104936E+10 |
| Minimum of Months | 0.111808E+09 | 22084771.01 | 69107612.04 | 0.129068E+09 | 337085.06 |
| Maximum of Months | 0.201023E+09 | 94095700.36 | 0.113432E+09 | 0.536996E+09 | 0.243237E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 W NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.115424E+09 | 44877482.19 | 70546591.29 | 0.148805E+09 | 0.225337E+09 |
| February | 0.119084E+09 | 43815973.67 | 75267809.98 | 0.173740E+09 | 0.165818E+09 |
| March | 0.171866E+09 | 69065691.27 | 0.102800E+09 | 0.306870E+09 | 0.108117E+09 |
| April | 0.201023E+09 | 94095700.36 | 0.106927E+09 | 0.458202E+09 | 28888007.10 |
| May | 0.196762E+09 | 83329964.89 | 0.113432E+09 | 0.537767E+09 | 2700562.65 |
| June | 0.179622E+09 | 70119107.14 | 0.109503E+09 | 0.520698E+09 | 2463857.57 |
| July | 0.137224E+09 | 26614336.26 | 0.110610E+09 | 0.411062E+09 | 338105.59 |
| August | 0.125827E+09 | 22084771.01 | 0.103743E+09 | 0.349540E+09 | 1047231.32 |
| September | 0.134501E+09 | 39798401.45 | 94702751.95 | 0.317102E+09 | 6184188.60 |
| October | 0.144267E+09 | 57399869.82 | 86866962.91 | 0.299496E+09 | 76784014.94 |
| November | 0.126283E+09 | 53795546.57 | 72487846.06 | 0.215772E+09 | 0.157904E+09 |
| December | 0.111808E+09 | 42700072.59 | 69107612.04 | 0.149258E+09 | 0.216840E+09 |
| Annual Sum or Average | 0.176369E+10 | 0.647697E+09 | 0.111599E+10 | 0.388831E+10 | 0.992423E+09 |
| Minimum of Months | 0.111808E+09 | 22084771.01 | 69107612.04 | 0.148805E+09 | 338105.59 |
| Maximum of Months | 0.201023E+09 | 94095700.36 | 0.113432E+09 | 0.537767E+09 | 0.225337E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N NWA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 83720776.50 | 0.00 | 83720776.50 | 56873655.25 | 0.353866E+09 |
| February | 89671001.12 | 0.00 | 89671001.12 | 90418507.11 | 0.257718E+09 |
| March | 0.119662E+09 | 11416.56 | 0.119651E+09 | 0.192149E+09 | 0.165930E+09 |
| April | 0.125924E+09 | 626385.41 | 0.125297E+09 | 0.345729E+09 | 43485469.50 |
| May | 0.144278E+09 | 4464536.23 | 0.139814E+09 | 0.515111E+09 | 4100260.19 |
| June | 0.143703E+09 | 4986643.04 | 0.138717E+09 | 0.538456E+09 | 3793871.81 |
| July | 0.147069E+09 | 2528891.87 | 0.144540E+09 | 0.506884E+09 | 478101.70 |
| August | 0.135248E+09 | 754189.90 | 0.134494E+09 | 0.420976E+09 | 1514870.95 |
| September | 0.116241E+09 | 14758.11 | 0.116226E+09 | 0.309522E+09 | 9351370.62 |
| October | 0.104047E+09 | 0.00 | 0.104047E+09 | 0.223437E+09 | 0.117390E+09 |
| November | 85286195.69 | 0.00 | 85286195.69 | 0.114707E+09 | 0.243504E+09 |
| December | 81671108.11 | 0.00 | 81671108.11 | 63061788.02 | 0.342254E+09 |
| Annual Sum or Average | 0.137652E+10 | 13386821.13 | 0.136313E+10 | 0.337732E+10 | 0.154339E+10 |
| Minimum of Months | 81671108.11 | 0.00 | 81671108.11 | 56873655.25 | 478101.70 |
| Maximum of Months | 0.147069E+09 | 4986643.04 | 0.144540E+09 | 0.538456E+09 | 0.353866E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.378498E+09 | 0.229085E+09 | 0.149413E+09 | 0.550432E+09 | 0.340971E+09 |
| February | 0.329963E+09 | 0.184565E+09 | 0.145398E+09 | 0.518783E+09 | 0.251434E+09 |
| March | 0.301718E+09 | 0.128904E+09 | 0.172815E+09 | 0.561744E+09 | 0.164950E+09 |
| April | 0.216806E+09 | 65697605.51 | 0.151109E+09 | 0.556487E+09 | 45294257.74 |
| May | 0.157039E+09 | 12190734.33 | 0.144848E+09 | 0.550069E+09 | 3889967.54 |
| June | 0.138893E+09 | 2831454.13 | 0.136062E+09 | 0.529710E+09 | 3787599.55 |
| July | 0.148818E+09 | 1657347.09 | 0.147161E+09 | 0.513215E+09 | 484340.15 |
| August | 0.156363E+09 | 6555053.33 | 0.149808E+09 | 0.467671E+09 | 1572287.73 |
| September | 0.212171E+09 | 60116108.52 | 0.152055E+09 | 0.509953E+09 | 9746842.84 |
| October | 0.362124E+09 | 0.200926E+09 | 0.161198E+09 | 0.734796E+09 | 0.117138E+09 |
| November | 0.442866E+09 | 0.293281E+09 | 0.149585E+09 | 0.772815E+09 | 0.238725E+09 |
| December | 0.405808E+09 | 0.253939E+09 | 0.151870E+09 | 0.615377E+09 | 0.335211E+09 |
| Annual Sum or Average | 0.325107E+10 | 0.143975E+10 | 0.181132E+10 | 0.688105E+10 | 0.151320E+10 |
| Minimum of Months | 0.138893E+09 | 1657347.09 | 0.136062E+09 | 0.467671E+09 | 484340.15 |
| Maximum of Months | 0.442866E+09 | 0.293281E+09 | 0.172815E+09 | 0.772815E+09 | 0.340971E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 E SEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.118372E+09 | 47740397.38 | 70631611.97 | 0.121939E+09 | 0.230240E+09 |
| February | 0.129403E+09 | 53274837.78 | 76127870.07 | 0.168598E+09 | 0.164011E+09 |
| March | 0.174956E+09 | 72128237.55 | 0.102828E+09 | 0.298251E+09 | 0.103353E+09 |
| April | 0.202044E+09 | 94375988.81 | 0.107668E+09 | 0.454531E+09 | 28115654.35 |
| May | 0.204826E+09 | 90815308.18 | 0.114011E+09 | 0.550324E+09 | 2524063.13 |
| June | 0.161251E+09 | 53480275.79 | 0.107771E+09 | 0.484743E+09 | 2451361.07 |
| July | 0.139881E+09 | 29385658.23 | 0.110495E+09 | 0.418786E+09 | 310031.74 |
| August | 0.126159E+09 | 21847583.13 | 0.104312E+09 | 0.348541E+09 | 980581.21 |
| September | 0.130197E+09 | 36084523.85 | 94112532.07 | 0.305240E+09 | 6218812.37 |
| October | 0.147656E+09 | 59709845.47 | 87945784.03 | 0.293856E+09 | 75520818.26 |
| November | 0.126367E+09 | 54128288.04 | 72238413.64 | 0.192352E+09 | 0.155805E+09 |
| December | 0.113839E+09 | 45058622.97 | 68780520.62 | 0.127255E+09 | 0.228456E+09 |
| Annual Sum or Average | 0.177495E+10 | 0.658030E+09 | 0.111692E+10 | 0.376441E+10 | 0.997987E+09 |
| Minimum of Months | 0.113839E+09 | 21847583.13 | 68780520.62 | 0.121939E+09 | 310031.74 |
| Maximum of Months | 0.204826E+09 | 94375988.81 | 0.114011E+09 | 0.550324E+09 | 0.230240E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 E NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.118372E+09 | 47740397.38 | 70631611.97 | 0.139128E+09 | 0.208916E+09 |
| February | 0.129403E+09 | 53274837.78 | 76127870.07 | 0.180918E+09 | 0.154977E+09 |
| March | 0.174956E+09 | 72128237.55 | 0.102828E+09 | 0.304526E+09 | 0.101049E+09 |
| April | 0.202044E+09 | 94375988.81 | 0.107668E+09 | 0.458100E+09 | 27646878.84 |
| May | 0.204826E+09 | 90815308.18 | 0.114011E+09 | 0.551139E+09 | 2513425.45 |
| June | 0.161251E+09 | 53480275.79 | 0.107771E+09 | 0.484690E+09 | 2443405.07 |
| July | 0.139881E+09 | 29385658.23 | 0.110495E+09 | 0.418817E+09 | 311208.13 |
| August | 0.126159E+09 | 21847583.13 | 0.104312E+09 | 0.349407E+09 | 974160.22 |
| September | 0.130197E+09 | 36084523.85 | 94112532.07 | 0.308513E+09 | 5973929.32 |
| October | 0.147656E+09 | 59709845.47 | 87945784.03 | 0.300884E+09 | 73419420.62 |
| November | 0.126367E+09 | 54128288.04 | 72238413.64 | 0.204624E+09 | 0.147902E+09 |
| December | 0.113839E+09 | 45058622.97 | 68780520.62 | 0.144484E+09 | 0.206648E+09 |
| Annual Sum or Average | 0.177495E+10 | 0.658030E+09 | 0.111692E+10 | 0.384523E+10 | 0.932774E+09 |
| Minimum of Months | 0.113839E+09 | 21847583.13 | 68780520.62 | 0.139128E+09 | 311208.13 |
| Maximum of Months | 0.204826E+09 | 94375988.81 | 0.114011E+09 | 0.551139E+09 | 0.208916E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N NEA
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 83720776.50 | 0.00 | 83720776.50 | 53091026.31 | 0.350037E+09 |
| February | 89671001.12 | 0.00 | 89671001.12 | 85032100.20 | 0.255647E+09 |
| March | 0.119662E+09 | 11416.56 | 0.119651E+09 | 0.187187E+09 | 0.164602E+09 |
| April | 0.125924E+09 | 626385.41 | 0.125297E+09 | 0.344319E+09 | 42977799.94 |
| May | 0.144278E+09 | 4464536.23 | 0.139814E+09 | 0.514474E+09 | 4003711.86 |
| June | 0.143703E+09 | 4986643.04 | 0.138717E+09 | 0.539040E+09 | 3731457.79 |
| July | 0.147069E+09 | 2528891.87 | 0.144540E+09 | 0.506814E+09 | 478365.22 |
| August | 0.135248E+09 | 754189.90 | 0.134494E+09 | 0.420857E+09 | 1514520.45 |
| September | 0.116241E+09 | 14758.11 | 0.116226E+09 | 0.309464E+09 | 9169211.70 |
| October | 0.104047E+09 | 0.00 | 0.104047E+09 | 0.221266E+09 | 0.116508E+09 |
| November | 85286195.69 | 0.00 | 85286195.69 | 0.110500E+09 | 0.240365E+09 |
| December | 81671108.11 | 0.00 | 81671108.11 | 58597484.49 | 0.338210E+09 |
| Annual Sum or Average | 0.137652E+10 | 13386821.13 | 0.136313E+10 | 0.335064E+10 | 0.152724E+10 |
| Minimum of Months | 81671108.11 | 0.00 | 81671108.11 | 53091026.31 | 478365.22 |
| Maximum of Months | 0.147069E+09 | 4986643.04 | 0.144540E+09 | 0.539040E+09 | 0.350037E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N N1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 83720776.50 | 0.00 | 83720776.50 | 55951390.96 | 0.361944E+09 |
| February | 89671001.12 | 0.00 | 89671001.12 | 89483315.45 | 0.264751E+09 |
| March | 0.119662E+09 | 11416.56 | 0.119651E+09 | 0.194822E+09 | 0.167550E+09 |
| April | 0.125924E+09 | 626385.41 | 0.125297E+09 | 0.355116E+09 | 42908033.61 |
| May | 0.144278E+09 | 4464536.23 | 0.139814E+09 | 0.528145E+09 | 3854398.07 |
| June | 0.143703E+09 | 4986643.04 | 0.138717E+09 | 0.551227E+09 | 3693922.69 |
| July | 0.147069E+09 | 2528891.87 | 0.144540E+09 | 0.517554E+09 | 479036.71 |
| August | 0.135248E+09 | 754189.90 | 0.134494E+09 | 0.429944E+09 | 1425748.14 |
| September | 0.116241E+09 | 14758.11 | 0.116226E+09 | 0.317016E+09 | 8919625.73 |
| October | 0.104047E+09 | 0.00 | 0.104047E+09 | 0.227680E+09 | 0.117787E+09 |
| November | 85286195.69 | 0.00 | 85286195.69 | 0.114432E+09 | 0.248688E+09 |
| December | 81671108.11 | 0.00 | 81671108.11 | 60871897.92 | 0.351965E+09 |
| Annual Sum or Average | 0.137652E+10 | 13386821.13 | 0.136313E+10 | 0.344224E+10 | 0.157397E+10 |
| Minimum of Months | 81671108.11 | 0.00 | 81671108.11 | 55951390.96 | 479036.71 |
| Maximum of Months | 0.147069E+09 | 4986643.04 | 0.144540E+09 | 0.551227E+09 | 0.361944E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 N N2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 83720776.50 | 0.00 | 83720776.50 | 55637356.37 | 0.361686E+09 |
| February | 89671001.12 | 0.00 | 89671001.12 | 89029859.54 | 0.264714E+09 |
| March | 0.119662E+09 | 11416.56 | 0.119651E+09 | 0.194476E+09 | 0.167504E+09 |
| April | 0.125924E+09 | 626385.41 | 0.125297E+09 | 0.355037E+09 | 42880077.39 |
| May | 0.144278E+09 | 4464536.23 | 0.139814E+09 | 0.528117E+09 | 3848530.27 |
| June | 0.143703E+09 | 4986643.04 | 0.138717E+09 | 0.551247E+09 | 3689878.77 |
| July | 0.147069E+09 | 2528891.87 | 0.144540E+09 | 0.517551E+09 | 479023.80 |
| August | 0.135248E+09 | 754189.90 | 0.134494E+09 | 0.429939E+09 | 1425774.45 |
| September | 0.116241E+09 | 14758.11 | 0.116226E+09 | 0.317009E+09 | 8908445.47 |
| October | 0.104047E+09 | 0.00 | 0.104047E+09 | 0.227559E+09 | 0.117737E+09 |
| November | 85286195.69 | 0.00 | 85286195.69 | 0.114164E+09 | 0.248470E+09 |
| December | 81671108.11 | 0.00 | 81671108.11 | 60536057.45 | 0.351725E+09 |
| Annual Sum or Average | 0.137652E+10 | 13386821.13 | 0.136313E+10 | 0.344030E+10 | 0.157307E+10 |
| Minimum of Months | 81671108.11 | 0.00 | 81671108.11 | 55637356.37 | 479023.80 |
| Maximum of Months | 0.147069E+09 | 4986643.04 | 0.144540E+09 | 0.551247E+09 | 0.361686E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S S1A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.378498E+09 | 0.229085E+09 | 0.149413E+09 | 0.549565E+09 | 0.357298E+09 |
| February | 0.329963E+09 | 0.184565E+09 | 0.145398E+09 | 0.520393E+09 | 0.261848E+09 |
| March | 0.301718E+09 | 0.128904E+09 | 0.172815E+09 | 0.567965E+09 | 0.167968E+09 |
| April | 0.216806E+09 | 65697605.51 | 0.151109E+09 | 0.566385E+09 | 45251098.22 |
| May | 0.157039E+09 | 12190734.33 | 0.144848E+09 | 0.563575E+09 | 3742500.63 |
| June | 0.138893E+09 | 2831454.13 | 0.136062E+09 | 0.541892E+09 | 3745541.23 |
| July | 0.148818E+09 | 1657347.09 | 0.147161E+09 | 0.524056E+09 | 484528.84 |
| August | 0.156363E+09 | 6555053.33 | 0.149808E+09 | 0.476565E+09 | 1472123.18 |
| September | 0.212171E+09 | 60116108.52 | 0.152055E+09 | 0.516954E+09 | 9507797.24 |
| October | 0.362124E+09 | 0.200926E+09 | 0.161198E+09 | 0.739957E+09 | 0.118476E+09 |
| November | 0.442866E+09 | 0.293281E+09 | 0.149585E+09 | 0.774552E+09 | 0.246429E+09 |
| December | 0.405808E+09 | 0.253939E+09 | 0.151870E+09 | 0.613188E+09 | 0.351385E+09 |
| Annual Sum or Average | 0.325107E+10 | 0.143975E+10 | 0.181132E+10 | 0.695505E+10 | 0.156761E+10 |
| Minimum of Months | 0.138893E+09 | 1657347.09 | 0.136062E+09 | 0.476565E+09 | 484528.84 |
| Maximum of Months | 0.442866E+09 | 0.293281E+09 | 0.172815E+09 | 0.774552E+09 | 0.357298E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW1 S S2A
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 0.378498E+09 | 0.229085E+09 | 0.149413E+09 | 0.549166E+09 | 0.357196E+09 |
| February | 0.329963E+09 | 0.184565E+09 | 0.145398E+09 | 0.520026E+09 | 0.261783E+09 |
| March | 0.301718E+09 | 0.128904E+09 | 0.172815E+09 | 0.567702E+09 | 0.167906E+09 |
| April | 0.216806E+09 | 65697605.51 | 0.151109E+09 | 0.566316E+09 | 45220539.66 |
| May | 0.157039E+09 | 12190734.33 | 0.144848E+09 | 0.563547E+09 | 3736586.53 |
| June | 0.138893E+09 | 2831454.13 | 0.136062E+09 | 0.541914E+09 | 3741157.23 |
| July | 0.148818E+09 | 1657347.09 | 0.147161E+09 | 0.524054E+09 | 484514.74 |
| August | 0.156363E+09 | 6555053.33 | 0.149808E+09 | 0.476561E+09 | 1472174.84 |
| September | 0.212171E+09 | 60116108.52 | 0.152055E+09 | 0.516949E+09 | 9496451.30 |
| October | 0.362124E+09 | 0.200926E+09 | 0.161198E+09 | 0.739870E+09 | 0.118428E+09 |
| November | 0.442866E+09 | 0.293281E+09 | 0.149585E+09 | 0.774360E+09 | 0.246316E+09 |
| December | 0.405808E+09 | 0.253939E+09 | 0.151870E+09 | 0.612864E+09 | 0.351282E+09 |
| Annual Sum or Average | 0.325107E+10 | 0.143975E+10 | 0.181132E+10 | 0.695333E+10 | 0.156706E+10 |
| Minimum of Months | 0.138893E+09 | 1657347.09 | 0.136062E+09 | 0.476561E+09 | 484514.74 |
| Maximum of Months | 0.442866E+09 | 0.293281E+09 | 0.172815E+09 | 0.774360E+09 | 0.357196E+09 |
Report: WindowEnergyReportMonthly
For: TWINDOW14
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 28403845.47 | 11455502.67 | 16948342.79 | 30958029.00 | 57867666.73 |
| February | 31050706.47 | 12783514.18 | 18267192.29 | 41074035.71 | 43074074.64 |
| March | 41981367.94 | 17307464.19 | 24673903.75 | 69800446.14 | 28943403.90 |
| April | 48481250.38 | 22645902.66 | 25835347.72 | 0.103849E+09 | 9623934.90 |
| May | 49148907.40 | 21791502.85 | 27357404.55 | 0.122821E+09 | 1584763.46 |
| June | 38692928.82 | 12832809.86 | 25860118.96 | 0.106632E+09 | 1376539.74 |
| July | 33564946.11 | 7051208.30 | 26513737.81 | 90093110.87 | 284030.17 |
| August | 30272480.42 | 5242416.50 | 25030063.92 | 74756972.34 | 1179894.14 |
| September | 31241313.52 | 8658628.38 | 22582685.14 | 67379466.55 | 4248656.69 |
| October | 35430569.31 | 14327620.46 | 21102948.85 | 68368249.80 | 22296773.09 |
| November | 30322204.43 | 12988303.04 | 17333901.39 | 46481121.40 | 41164669.74 |
| December | 27316165.87 | 10811999.99 | 16504165.89 | 32177343.45 | 57595399.96 |
| Annual Sum or Average | 0.425907E+09 | 0.157897E+09 | 0.268010E+09 | 0.854390E+09 | 0.269240E+09 |
| Minimum of Months | 27316165.87 | 5242416.50 | 16504165.89 | 30958029.00 | 284030.17 |
| Maximum of Months | 49148907.40 | 22645902.66 | 27357404.55 | 0.122821E+09 | 57867666.73 |
Report: WindowEnergyReportMonthly
For: ENTRANCE DOOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 84593720.47 | 34117337.82 | 50476382.65 | 84590954.29 | 0.185328E+09 |
| February | 92476731.25 | 38072486.56 | 54404244.69 | 0.118273E+09 | 0.135096E+09 |
| March | 0.125031E+09 | 51545935.56 | 73485025.79 | 0.203404E+09 | 92850340.36 |
| April | 0.144389E+09 | 67445133.87 | 76944094.97 | 0.296143E+09 | 37205429.48 |
| May | 0.146378E+09 | 64900518.60 | 81477159.01 | 0.341530E+09 | 10728311.30 |
| June | 0.115237E+09 | 38219301.39 | 77017869.89 | 0.290990E+09 | 8023596.19 |
| July | 99964762.60 | 21000253.11 | 78964509.48 | 0.241580E+09 | 3718006.90 |
| August | 90158980.40 | 15613220.99 | 74545759.41 | 0.201683E+09 | 9334706.20 |
| September | 93044406.48 | 25787550.12 | 67256856.36 | 0.185171E+09 | 24712622.22 |
| October | 0.105521E+09 | 42671219.36 | 62849833.43 | 0.190826E+09 | 81461497.12 |
| November | 90307070.88 | 38682398.76 | 51624672.12 | 0.128903E+09 | 0.136878E+09 |
| December | 81354339.96 | 32200826.67 | 49153513.29 | 84605517.39 | 0.190349E+09 |
| Annual Sum or Average | 0.126846E+10 | 0.470256E+09 | 0.798200E+09 | 0.236770E+10 | 0.915686E+09 |
| Minimum of Months | 81354339.96 | 15613220.99 | 49153513.29 | 84590954.29 | 3718006.90 |
| Maximum of Months | 0.146378E+09 | 67445133.87 | 81477159.01 | 0.341530E+09 | 0.190349E+09 |
Report: WindowEnergyReportMonthly
For: MWINDOW14
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
| January | 28403845.47 | 11455502.67 | 16948342.79 | 25761396.68 | 66388296.34 |
| February | 31050706.47 | 12783514.18 | 18267192.29 | 37894330.20 | 47803927.34 |
| March | 41981367.94 | 17307464.19 | 24673903.75 | 68748036.30 | 30561686.48 |
| April | 48481250.38 | 22645902.66 | 25835347.72 | 0.105226E+09 | 10026701.16 |
| May | 49148907.40 | 21791502.85 | 27357404.55 | 0.125789E+09 | 1601718.47 |
| June | 38692928.82 | 12832809.86 | 25860118.96 | 0.109920E+09 | 1314571.93 |
| July | 33564946.11 | 7051208.30 | 26513737.81 | 93339686.61 | 275894.79 |
| August | 30272480.42 | 5242416.50 | 25030063.92 | 77329753.61 | 1104940.04 |
| September | 31241313.52 | 8658628.38 | 22582685.14 | 68847899.05 | 4204775.19 |
| October | 35430569.31 | 14327620.46 | 21102948.85 | 68161394.53 | 23346608.30 |
| November | 30322204.43 | 12988303.04 | 17333901.39 | 44175209.87 | 44448782.49 |
| December | 27316165.87 | 10811999.99 | 16504165.89 | 27195039.18 | 66009154.12 |
| Annual Sum or Average | 0.425907E+09 | 0.157897E+09 | 0.268010E+09 | 0.852388E+09 | 0.297087E+09 |
| Minimum of Months | 27316165.87 | 5242416.50 | 16504165.89 | 25761396.68 | 275894.79 |
| Maximum of Months | 49148907.40 | 22645902.66 | 27357404.55 | 0.125789E+09 | 66388296.34 |
Report: WindowZoneSummaryMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 247.56 | 240.35 | 184.41 | 102.29 | 82.12 | 0.00 | 0.00 |
| February | 283.57 | 187.13 | 185.62 | 94.40 | 91.21 | 0.00 | 0.00 |
| March | 330.76 | 105.04 | 176.82 | 73.91 | 102.90 | 0.00 | 0.00 |
| April | 400.39 | 30.42 | 161.20 | 61.65 | 99.55 | 0.00 | 0.00 |
| May | 413.12 | 2.86 | 132.09 | 35.66 | 96.43 | 0.00 | 0.00 |
| June | 410.19 | 2.77 | 122.88 | 28.14 | 94.74 | 0.00 | 0.00 |
| July | 345.96 | 0.43 | 106.80 | 10.56 | 96.24 | 0.00 | 0.00 |
| August | 304.16 | 1.73 | 105.36 | 10.69 | 94.66 | 0.00 | 0.00 |
| September | 318.29 | 9.77 | 133.75 | 38.55 | 95.20 | 0.00 | 0.00 |
| October | 385.59 | 82.76 | 189.06 | 96.45 | 92.62 | 0.00 | 0.00 |
| November | 376.17 | 169.29 | 219.58 | 133.90 | 85.68 | 0.00 | 0.00 |
| December | 269.73 | 237.05 | 193.26 | 110.75 | 82.50 | 0.00 | 0.00 |
| Annual Sum or Average | 340.53 | 88.72 | 159.02 | 66.19 | 92.82 | 0.00 | 0.00 |
| Minimum of Months | 247.56 | 0.43 | 105.36 | 10.56 | 82.12 | 0.00 | 0.00 |
| Maximum of Months | 413.12 | 240.35 | 219.58 | 133.90 | 102.90 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 68.66 | 238.04 | 74.35 | 16.76 | 57.60 | 0.00 | 0.00 |
| February | 107.69 | 185.32 | 86.29 | 18.11 | 68.18 | 0.00 | 0.00 |
| March | 192.15 | 103.08 | 108.84 | 25.79 | 83.05 | 0.00 | 0.00 |
| April | 318.79 | 28.81 | 126.14 | 36.54 | 89.59 | 0.00 | 0.00 |
| May | 400.00 | 2.87 | 127.33 | 32.78 | 94.55 | 0.00 | 0.00 |
| June | 413.69 | 2.77 | 124.74 | 28.98 | 95.76 | 0.00 | 0.00 |
| July | 343.64 | 0.44 | 106.14 | 10.88 | 95.26 | 0.00 | 0.00 |
| August | 286.75 | 1.70 | 97.47 | 8.53 | 88.95 | 0.00 | 0.00 |
| September | 240.82 | 9.14 | 96.74 | 15.36 | 81.38 | 0.00 | 0.00 |
| October | 194.42 | 81.30 | 92.71 | 21.43 | 71.28 | 0.00 | 0.00 |
| November | 122.12 | 171.41 | 81.62 | 20.75 | 60.87 | 0.00 | 0.00 |
| December | 64.22 | 243.62 | 72.24 | 15.94 | 56.29 | 0.00 | 0.00 |
| Annual Sum or Average | 229.93 | 88.64 | 99.58 | 20.96 | 78.61 | 0.00 | 0.00 |
| Minimum of Months | 64.22 | 0.44 | 72.24 | 8.53 | 56.29 | 0.00 | 0.00 |
| Maximum of Months | 413.69 | 243.62 | 127.33 | 36.54 | 95.76 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 248.13 | 235.40 | 185.51 | 103.35 | 82.16 | 0.00 | 0.00 |
| February | 285.46 | 192.98 | 189.88 | 98.31 | 91.57 | 0.00 | 0.00 |
| March | 318.21 | 123.68 | 177.97 | 75.06 | 102.91 | 0.00 | 0.00 |
| April | 364.52 | 57.91 | 161.59 | 61.76 | 99.84 | 0.00 | 0.00 |
| May | 361.16 | 19.77 | 135.11 | 38.46 | 96.65 | 0.00 | 0.00 |
| June | 334.03 | 15.52 | 115.80 | 21.73 | 94.07 | 0.00 | 0.00 |
| July | 278.35 | 10.00 | 107.79 | 11.59 | 96.20 | 0.00 | 0.00 |
| August | 252.82 | 21.52 | 105.48 | 10.60 | 94.88 | 0.00 | 0.00 |
| September | 278.46 | 47.58 | 132.09 | 37.11 | 94.97 | 0.00 | 0.00 |
| October | 365.85 | 121.06 | 190.33 | 97.31 | 93.02 | 0.00 | 0.00 |
| November | 363.35 | 193.39 | 219.61 | 134.03 | 85.58 | 0.00 | 0.00 |
| December | 269.74 | 242.35 | 194.01 | 111.63 | 82.38 | 0.00 | 0.00 |
| Annual Sum or Average | 309.93 | 106.36 | 159.37 | 66.52 | 92.85 | 0.00 | 0.00 |
| Minimum of Months | 248.13 | 10.00 | 105.48 | 10.60 | 82.16 | 0.00 | 0.00 |
| Maximum of Months | 365.85 | 242.35 | 219.61 | 134.03 | 102.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 55.58 | 223.64 | 75.45 | 17.82 | 57.63 | 0.00 | 0.00 |
| February | 103.14 | 174.69 | 90.56 | 22.02 | 68.53 | 0.00 | 0.00 |
| March | 187.11 | 96.93 | 110.00 | 26.93 | 83.06 | 0.00 | 0.00 |
| April | 317.97 | 27.73 | 126.53 | 36.65 | 89.88 | 0.00 | 0.00 |
| May | 405.10 | 2.77 | 130.34 | 35.57 | 94.77 | 0.00 | 0.00 |
| June | 400.08 | 2.73 | 117.65 | 22.56 | 95.10 | 0.00 | 0.00 |
| July | 346.36 | 0.42 | 107.13 | 11.92 | 95.22 | 0.00 | 0.00 |
| August | 286.72 | 1.66 | 97.60 | 8.44 | 89.16 | 0.00 | 0.00 |
| September | 237.34 | 8.84 | 95.08 | 13.93 | 81.15 | 0.00 | 0.00 |
| October | 192.69 | 78.03 | 93.98 | 22.29 | 71.68 | 0.00 | 0.00 |
| November | 112.92 | 163.42 | 81.66 | 20.88 | 60.77 | 0.00 | 0.00 |
| December | 56.20 | 234.01 | 73.00 | 16.82 | 56.17 | 0.00 | 0.00 |
| Annual Sum or Average | 225.64 | 84.20 | 99.93 | 21.29 | 78.64 | 0.00 | 0.00 |
| Minimum of Months | 55.58 | 0.42 | 73.00 | 8.44 | 56.17 | 0.00 | 0.00 |
| Maximum of Months | 405.10 | 234.01 | 130.34 | 36.65 | 95.22 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 16.46 | 153.22 | 31.26 | 0.00 | 31.26 | 0.00 | 0.00 |
| February | 35.61 | 117.17 | 37.07 | 0.00 | 37.07 | 0.00 | 0.00 |
| March | 75.14 | 63.23 | 44.68 | 0.00 | 44.67 | 0.00 | 0.00 |
| April | 140.43 | 17.12 | 48.58 | 0.24 | 48.34 | 0.00 | 0.00 |
| May | 200.07 | 1.60 | 53.87 | 1.67 | 52.20 | 0.00 | 0.00 |
| June | 214.95 | 1.57 | 55.44 | 1.92 | 53.52 | 0.00 | 0.00 |
| July | 193.78 | 0.23 | 54.91 | 0.94 | 53.97 | 0.00 | 0.00 |
| August | 160.31 | 0.82 | 50.50 | 0.28 | 50.21 | 0.00 | 0.00 |
| September | 121.73 | 4.75 | 44.85 | 0.01 | 44.84 | 0.00 | 0.00 |
| October | 84.33 | 48.16 | 38.85 | 0.00 | 38.85 | 0.00 | 0.00 |
| November | 41.64 | 104.32 | 32.90 | 0.00 | 32.90 | 0.00 | 0.00 |
| December | 16.56 | 154.27 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Annual Sum or Average | 108.78 | 55.29 | 43.65 | 0.42 | 43.22 | 0.00 | 0.00 |
| Minimum of Months | 16.46 | 0.23 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Maximum of Months | 214.95 | 154.27 | 55.44 | 1.92 | 53.97 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 16.42 | 153.26 | 31.26 | 0.00 | 31.26 | 0.00 | 0.00 |
| February | 35.54 | 117.24 | 37.07 | 0.00 | 37.07 | 0.00 | 0.00 |
| March | 75.09 | 63.24 | 44.68 | 0.00 | 44.67 | 0.00 | 0.00 |
| April | 140.42 | 17.12 | 48.58 | 0.24 | 48.34 | 0.00 | 0.00 |
| May | 200.06 | 1.60 | 53.87 | 1.67 | 52.20 | 0.00 | 0.00 |
| June | 214.96 | 1.57 | 55.44 | 1.92 | 53.52 | 0.00 | 0.00 |
| July | 193.78 | 0.23 | 54.91 | 0.94 | 53.97 | 0.00 | 0.00 |
| August | 160.30 | 0.82 | 50.50 | 0.28 | 50.21 | 0.00 | 0.00 |
| September | 121.73 | 4.75 | 44.85 | 0.01 | 44.84 | 0.00 | 0.00 |
| October | 84.31 | 48.16 | 38.85 | 0.00 | 38.85 | 0.00 | 0.00 |
| November | 41.61 | 104.33 | 32.90 | 0.00 | 32.90 | 0.00 | 0.00 |
| December | 16.53 | 154.28 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Annual Sum or Average | 108.76 | 55.30 | 43.65 | 0.42 | 43.22 | 0.00 | 0.00 |
| Minimum of Months | 16.42 | 0.23 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Maximum of Months | 214.96 | 154.28 | 55.44 | 1.92 | 53.97 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 202.56 | 146.49 | 141.32 | 85.53 | 55.78 | 0.00 | 0.00 |
| February | 216.82 | 114.24 | 136.39 | 76.29 | 60.10 | 0.00 | 0.00 |
| March | 215.83 | 64.08 | 112.65 | 48.13 | 64.52 | 0.00 | 0.00 |
| April | 222.98 | 18.36 | 83.64 | 25.35 | 58.30 | 0.00 | 0.00 |
| May | 213.34 | 1.59 | 58.63 | 4.55 | 54.08 | 0.00 | 0.00 |
| June | 211.35 | 1.59 | 53.59 | 1.09 | 52.49 | 0.00 | 0.00 |
| July | 196.04 | 0.23 | 55.56 | 0.62 | 54.94 | 0.00 | 0.00 |
| August | 177.86 | 0.86 | 58.38 | 2.45 | 55.93 | 0.00 | 0.00 |
| September | 199.93 | 5.18 | 81.86 | 23.19 | 58.66 | 0.00 | 0.00 |
| October | 277.37 | 48.87 | 135.20 | 75.02 | 60.18 | 0.00 | 0.00 |
| November | 299.39 | 101.54 | 170.86 | 113.15 | 57.71 | 0.00 | 0.00 |
| December | 226.20 | 143.45 | 151.51 | 94.81 | 56.70 | 0.00 | 0.00 |
| Annual Sum or Average | 221.55 | 53.62 | 103.09 | 45.65 | 57.44 | 0.00 | 0.00 |
| Minimum of Months | 177.86 | 0.23 | 53.59 | 0.62 | 52.49 | 0.00 | 0.00 |
| Maximum of Months | 299.39 | 146.49 | 170.86 | 113.15 | 64.52 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 202.66 | 146.27 | 141.32 | 85.53 | 55.78 | 0.00 | 0.00 |
| February | 216.64 | 114.46 | 136.39 | 76.29 | 60.10 | 0.00 | 0.00 |
| March | 215.34 | 64.67 | 112.65 | 48.13 | 64.52 | 0.00 | 0.00 |
| April | 221.98 | 18.98 | 83.64 | 25.35 | 58.30 | 0.00 | 0.00 |
| May | 211.74 | 1.73 | 58.63 | 4.55 | 54.08 | 0.00 | 0.00 |
| June | 209.75 | 1.71 | 53.59 | 1.09 | 52.49 | 0.00 | 0.00 |
| July | 194.28 | 0.25 | 55.56 | 0.62 | 54.94 | 0.00 | 0.00 |
| August | 176.35 | 1.00 | 58.38 | 2.45 | 55.93 | 0.00 | 0.00 |
| September | 198.74 | 5.73 | 81.86 | 23.19 | 58.66 | 0.00 | 0.00 |
| October | 276.65 | 49.83 | 135.20 | 75.02 | 60.18 | 0.00 | 0.00 |
| November | 298.94 | 102.23 | 170.86 | 113.15 | 57.71 | 0.00 | 0.00 |
| December | 226.10 | 143.56 | 151.51 | 94.81 | 56.70 | 0.00 | 0.00 |
| Annual Sum or Average | 220.67 | 53.95 | 103.09 | 45.65 | 57.44 | 0.00 | 0.00 |
| Minimum of Months | 176.35 | 0.25 | 53.59 | 0.62 | 52.49 | 0.00 | 0.00 |
| Maximum of Months | 298.94 | 146.27 | 170.86 | 113.15 | 64.52 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 243.71 | 243.85 | 184.41 | 102.29 | 82.12 | 0.00 | 0.00 |
| February | 278.58 | 192.25 | 185.62 | 94.40 | 91.21 | 0.00 | 0.00 |
| March | 326.48 | 108.38 | 176.82 | 73.91 | 102.90 | 0.00 | 0.00 |
| April | 398.91 | 30.86 | 161.20 | 61.65 | 99.55 | 0.00 | 0.00 |
| May | 416.08 | 2.68 | 132.09 | 35.66 | 96.43 | 0.00 | 0.00 |
| June | 415.77 | 2.46 | 122.88 | 28.14 | 94.74 | 0.00 | 0.00 |
| July | 354.58 | 0.32 | 106.80 | 10.56 | 96.24 | 0.00 | 0.00 |
| August | 313.19 | 1.01 | 105.36 | 10.69 | 94.66 | 0.00 | 0.00 |
| September | 325.19 | 6.80 | 133.75 | 38.55 | 95.20 | 0.00 | 0.00 |
| October | 389.00 | 77.27 | 189.06 | 96.45 | 92.62 | 0.00 | 0.00 |
| November | 377.25 | 165.65 | 219.58 | 133.90 | 85.68 | 0.00 | 0.00 |
| December | 268.81 | 236.03 | 193.26 | 110.75 | 82.50 | 0.00 | 0.00 |
| Annual Sum or Average | 342.41 | 88.53 | 159.02 | 66.19 | 92.82 | 0.00 | 0.00 |
| Minimum of Months | 243.71 | 0.32 | 105.36 | 10.56 | 82.12 | 0.00 | 0.00 |
| Maximum of Months | 416.08 | 243.85 | 219.58 | 133.90 | 102.90 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 66.21 | 243.97 | 74.35 | 16.76 | 57.60 | 0.00 | 0.00 |
| February | 102.55 | 195.27 | 86.29 | 18.11 | 68.18 | 0.00 | 0.00 |
| March | 187.85 | 107.88 | 108.84 | 25.79 | 83.05 | 0.00 | 0.00 |
| April | 317.53 | 29.52 | 126.14 | 36.54 | 89.59 | 0.00 | 0.00 |
| May | 402.99 | 2.69 | 127.33 | 32.78 | 94.55 | 0.00 | 0.00 |
| June | 419.36 | 2.45 | 124.74 | 28.98 | 95.76 | 0.00 | 0.00 |
| July | 352.21 | 0.32 | 106.14 | 10.88 | 95.26 | 0.00 | 0.00 |
| August | 295.92 | 0.98 | 97.47 | 8.53 | 88.95 | 0.00 | 0.00 |
| September | 248.30 | 6.36 | 96.74 | 15.36 | 81.38 | 0.00 | 0.00 |
| October | 198.49 | 76.23 | 92.71 | 21.43 | 71.28 | 0.00 | 0.00 |
| November | 124.22 | 167.90 | 81.62 | 20.75 | 60.87 | 0.00 | 0.00 |
| December | 65.49 | 240.41 | 72.24 | 15.94 | 56.29 | 0.00 | 0.00 |
| Annual Sum or Average | 232.32 | 89.05 | 99.58 | 20.96 | 78.61 | 0.00 | 0.00 |
| Minimum of Months | 65.49 | 0.32 | 72.24 | 8.53 | 56.29 | 0.00 | 0.00 |
| Maximum of Months | 419.36 | 243.97 | 127.33 | 36.54 | 95.76 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 239.73 | 237.77 | 185.51 | 103.35 | 82.16 | 0.00 | 0.00 |
| February | 280.34 | 187.10 | 189.88 | 98.31 | 91.57 | 0.00 | 0.00 |
| March | 322.64 | 103.29 | 177.97 | 75.06 | 102.91 | 0.00 | 0.00 |
| April | 397.73 | 29.35 | 161.59 | 61.76 | 99.84 | 0.00 | 0.00 |
| May | 421.03 | 2.55 | 135.11 | 38.46 | 96.65 | 0.00 | 0.00 |
| June | 402.12 | 2.44 | 115.80 | 21.73 | 94.07 | 0.00 | 0.00 |
| July | 357.48 | 0.32 | 107.79 | 11.59 | 96.20 | 0.00 | 0.00 |
| August | 313.14 | 0.99 | 105.48 | 10.60 | 94.88 | 0.00 | 0.00 |
| September | 321.81 | 6.58 | 132.09 | 37.11 | 94.97 | 0.00 | 0.00 |
| October | 388.70 | 75.33 | 190.33 | 97.31 | 93.02 | 0.00 | 0.00 |
| November | 372.41 | 161.95 | 219.61 | 134.03 | 85.58 | 0.00 | 0.00 |
| December | 267.06 | 232.77 | 194.01 | 111.63 | 82.38 | 0.00 | 0.00 |
| Annual Sum or Average | 340.48 | 86.28 | 159.37 | 66.52 | 92.85 | 0.00 | 0.00 |
| Minimum of Months | 239.73 | 0.32 | 105.48 | 10.60 | 82.16 | 0.00 | 0.00 |
| Maximum of Months | 421.03 | 237.77 | 219.61 | 134.03 | 102.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 52.83 | 229.33 | 75.45 | 17.82 | 57.63 | 0.00 | 0.00 |
| February | 97.53 | 183.82 | 90.56 | 22.02 | 68.53 | 0.00 | 0.00 |
| March | 182.24 | 101.30 | 110.00 | 26.93 | 83.06 | 0.00 | 0.00 |
| April | 316.62 | 28.35 | 126.53 | 36.65 | 89.88 | 0.00 | 0.00 |
| May | 407.98 | 2.59 | 130.34 | 35.57 | 94.77 | 0.00 | 0.00 |
| June | 405.70 | 2.42 | 117.65 | 22.56 | 95.10 | 0.00 | 0.00 |
| July | 355.11 | 0.31 | 107.13 | 11.92 | 95.22 | 0.00 | 0.00 |
| August | 295.87 | 0.96 | 97.60 | 8.44 | 89.16 | 0.00 | 0.00 |
| September | 244.92 | 6.14 | 95.08 | 13.93 | 81.15 | 0.00 | 0.00 |
| October | 197.00 | 73.26 | 93.98 | 22.29 | 71.68 | 0.00 | 0.00 |
| November | 115.12 | 159.74 | 81.66 | 20.88 | 60.77 | 0.00 | 0.00 |
| December | 57.43 | 230.97 | 73.00 | 16.82 | 56.17 | 0.00 | 0.00 |
| Annual Sum or Average | 227.96 | 84.51 | 99.93 | 21.29 | 78.64 | 0.00 | 0.00 |
| Minimum of Months | 52.83 | 0.31 | 73.00 | 8.44 | 56.17 | 0.00 | 0.00 |
| Maximum of Months | 407.98 | 230.97 | 130.34 | 36.65 | 95.22 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 15.08 | 157.93 | 31.26 | 0.00 | 31.26 | 0.00 | 0.00 |
| February | 33.63 | 121.69 | 37.07 | 0.00 | 37.07 | 0.00 | 0.00 |
| March | 73.55 | 65.19 | 44.68 | 0.00 | 44.67 | 0.00 | 0.00 |
| April | 140.62 | 17.20 | 48.58 | 0.24 | 48.34 | 0.00 | 0.00 |
| May | 202.38 | 1.47 | 53.87 | 1.67 | 52.20 | 0.00 | 0.00 |
| June | 218.35 | 1.39 | 55.44 | 1.92 | 53.52 | 0.00 | 0.00 |
| July | 198.34 | 0.19 | 54.91 | 0.94 | 53.97 | 0.00 | 0.00 |
| August | 164.97 | 0.52 | 50.50 | 0.28 | 50.21 | 0.00 | 0.00 |
| September | 125.69 | 3.53 | 44.85 | 0.01 | 44.84 | 0.00 | 0.00 |
| October | 86.51 | 45.69 | 38.85 | 0.00 | 38.85 | 0.00 | 0.00 |
| November | 42.73 | 102.35 | 32.90 | 0.00 | 32.90 | 0.00 | 0.00 |
| December | 16.72 | 153.91 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Annual Sum or Average | 110.27 | 55.65 | 43.65 | 0.42 | 43.22 | 0.00 | 0.00 |
| Minimum of Months | 15.08 | 0.19 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Maximum of Months | 218.35 | 157.93 | 55.44 | 1.92 | 53.97 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 15.03 | 157.98 | 31.26 | 0.00 | 31.26 | 0.00 | 0.00 |
| February | 33.56 | 121.73 | 37.07 | 0.00 | 37.07 | 0.00 | 0.00 |
| March | 73.50 | 65.20 | 44.68 | 0.00 | 44.67 | 0.00 | 0.00 |
| April | 140.61 | 17.20 | 48.58 | 0.24 | 48.34 | 0.00 | 0.00 |
| May | 202.37 | 1.47 | 53.87 | 1.67 | 52.20 | 0.00 | 0.00 |
| June | 218.36 | 1.39 | 55.44 | 1.92 | 53.52 | 0.00 | 0.00 |
| July | 198.34 | 0.19 | 54.91 | 0.94 | 53.97 | 0.00 | 0.00 |
| August | 164.96 | 0.52 | 50.50 | 0.28 | 50.21 | 0.00 | 0.00 |
| September | 125.69 | 3.53 | 44.85 | 0.01 | 44.84 | 0.00 | 0.00 |
| October | 86.49 | 45.69 | 38.85 | 0.00 | 38.85 | 0.00 | 0.00 |
| November | 42.69 | 102.34 | 32.90 | 0.00 | 32.90 | 0.00 | 0.00 |
| December | 16.68 | 153.94 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Annual Sum or Average | 110.24 | 55.66 | 43.65 | 0.42 | 43.22 | 0.00 | 0.00 |
| Minimum of Months | 15.03 | 0.19 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Maximum of Months | 218.36 | 157.98 | 55.44 | 1.92 | 53.97 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 200.16 | 148.26 | 141.32 | 85.53 | 55.78 | 0.00 | 0.00 |
| February | 214.24 | 116.35 | 136.39 | 76.29 | 60.10 | 0.00 | 0.00 |
| March | 213.93 | 65.19 | 112.65 | 48.13 | 64.52 | 0.00 | 0.00 |
| April | 222.77 | 18.25 | 83.64 | 25.35 | 58.30 | 0.00 | 0.00 |
| May | 215.65 | 1.45 | 58.63 | 4.55 | 54.08 | 0.00 | 0.00 |
| June | 214.75 | 1.41 | 53.59 | 1.09 | 52.49 | 0.00 | 0.00 |
| July | 200.75 | 0.19 | 55.56 | 0.62 | 54.94 | 0.00 | 0.00 |
| August | 182.44 | 0.54 | 58.38 | 2.45 | 55.93 | 0.00 | 0.00 |
| September | 203.37 | 3.83 | 81.86 | 23.19 | 58.66 | 0.00 | 0.00 |
| October | 278.88 | 46.08 | 135.20 | 75.02 | 60.18 | 0.00 | 0.00 |
| November | 299.57 | 99.63 | 170.86 | 113.15 | 57.71 | 0.00 | 0.00 |
| December | 225.21 | 143.07 | 151.51 | 94.81 | 56.70 | 0.00 | 0.00 |
| Annual Sum or Average | 222.58 | 53.42 | 103.09 | 45.65 | 57.44 | 0.00 | 0.00 |
| Minimum of Months | 182.44 | 0.19 | 53.59 | 0.62 | 52.49 | 0.00 | 0.00 |
| Maximum of Months | 299.57 | 148.26 | 170.86 | 113.15 | 64.52 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 200.13 | 148.25 | 141.32 | 85.53 | 55.78 | 0.00 | 0.00 |
| February | 214.19 | 116.36 | 136.39 | 76.29 | 60.10 | 0.00 | 0.00 |
| March | 213.89 | 65.19 | 112.65 | 48.13 | 64.52 | 0.00 | 0.00 |
| April | 222.75 | 18.24 | 83.64 | 25.35 | 58.30 | 0.00 | 0.00 |
| May | 215.64 | 1.45 | 58.63 | 4.55 | 54.08 | 0.00 | 0.00 |
| June | 214.75 | 1.41 | 53.59 | 1.09 | 52.49 | 0.00 | 0.00 |
| July | 200.75 | 0.19 | 55.56 | 0.62 | 54.94 | 0.00 | 0.00 |
| August | 182.44 | 0.54 | 58.38 | 2.45 | 55.93 | 0.00 | 0.00 |
| September | 203.37 | 3.82 | 81.86 | 23.19 | 58.66 | 0.00 | 0.00 |
| October | 278.87 | 46.08 | 135.20 | 75.02 | 60.18 | 0.00 | 0.00 |
| November | 299.54 | 99.63 | 170.86 | 113.15 | 57.71 | 0.00 | 0.00 |
| December | 225.17 | 143.07 | 151.51 | 94.81 | 56.70 | 0.00 | 0.00 |
| Annual Sum or Average | 222.56 | 53.42 | 103.09 | 45.65 | 57.44 | 0.00 | 0.00 |
| Minimum of Months | 182.44 | 0.19 | 53.59 | 0.62 | 52.49 | 0.00 | 0.00 |
| Maximum of Months | 299.54 | 148.25 | 170.86 | 113.15 | 64.52 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 251.47 | 214.83 | 184.41 | 102.29 | 82.12 | 0.00 | 0.00 |
| February | 280.83 | 174.31 | 185.62 | 94.40 | 91.21 | 0.00 | 0.00 |
| March | 322.86 | 102.77 | 176.82 | 73.91 | 102.90 | 0.00 | 0.00 |
| April | 390.57 | 28.99 | 161.20 | 61.65 | 99.55 | 0.00 | 0.00 |
| May | 406.10 | 2.50 | 132.09 | 35.66 | 96.43 | 0.00 | 0.00 |
| June | 405.03 | 2.41 | 122.88 | 28.14 | 94.74 | 0.00 | 0.00 |
| July | 345.10 | 0.31 | 106.80 | 10.56 | 96.24 | 0.00 | 0.00 |
| August | 304.82 | 0.98 | 105.36 | 10.69 | 94.66 | 0.00 | 0.00 |
| September | 317.84 | 6.31 | 133.75 | 38.55 | 95.20 | 0.00 | 0.00 |
| October | 383.97 | 73.35 | 189.06 | 96.45 | 92.62 | 0.00 | 0.00 |
| November | 376.51 | 155.03 | 219.58 | 133.90 | 85.68 | 0.00 | 0.00 |
| December | 276.18 | 210.23 | 193.26 | 110.75 | 82.50 | 0.00 | 0.00 |
| Annual Sum or Average | 338.54 | 80.59 | 159.02 | 66.19 | 92.82 | 0.00 | 0.00 |
| Minimum of Months | 251.47 | 0.31 | 105.36 | 10.56 | 82.12 | 0.00 | 0.00 |
| Maximum of Months | 406.10 | 214.83 | 219.58 | 133.90 | 102.90 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 73.78 | 213.23 | 74.35 | 16.76 | 57.60 | 0.00 | 0.00 |
| February | 107.64 | 173.52 | 86.29 | 18.11 | 68.18 | 0.00 | 0.00 |
| March | 185.95 | 101.95 | 108.84 | 25.79 | 83.05 | 0.00 | 0.00 |
| April | 310.12 | 27.88 | 126.14 | 36.54 | 89.59 | 0.00 | 0.00 |
| May | 393.09 | 2.53 | 127.33 | 32.78 | 94.55 | 0.00 | 0.00 |
| June | 408.62 | 2.41 | 124.74 | 28.98 | 95.76 | 0.00 | 0.00 |
| July | 342.72 | 0.30 | 106.14 | 10.88 | 95.26 | 0.00 | 0.00 |
| August | 287.68 | 0.95 | 97.47 | 8.53 | 88.95 | 0.00 | 0.00 |
| September | 241.75 | 5.99 | 96.74 | 15.36 | 81.38 | 0.00 | 0.00 |
| October | 195.24 | 72.49 | 92.71 | 21.43 | 71.28 | 0.00 | 0.00 |
| November | 126.78 | 154.14 | 81.62 | 20.75 | 60.87 | 0.00 | 0.00 |
| December | 75.80 | 205.27 | 72.24 | 15.94 | 56.29 | 0.00 | 0.00 |
| Annual Sum or Average | 229.63 | 79.64 | 99.58 | 20.96 | 78.61 | 0.00 | 0.00 |
| Minimum of Months | 73.78 | 0.30 | 72.24 | 8.53 | 56.29 | 0.00 | 0.00 |
| Maximum of Months | 408.62 | 213.23 | 127.33 | 36.54 | 95.76 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 247.98 | 210.21 | 185.51 | 103.35 | 82.16 | 0.00 | 0.00 |
| February | 282.37 | 169.96 | 189.88 | 98.31 | 91.57 | 0.00 | 0.00 |
| March | 319.08 | 98.17 | 177.97 | 75.06 | 102.91 | 0.00 | 0.00 |
| April | 389.39 | 27.66 | 161.59 | 61.76 | 99.84 | 0.00 | 0.00 |
| May | 410.81 | 2.37 | 135.11 | 38.46 | 96.65 | 0.00 | 0.00 |
| June | 391.37 | 2.40 | 115.80 | 21.73 | 94.07 | 0.00 | 0.00 |
| July | 347.97 | 0.30 | 107.79 | 11.59 | 96.20 | 0.00 | 0.00 |
| August | 304.73 | 0.95 | 105.48 | 10.60 | 94.88 | 0.00 | 0.00 |
| September | 314.44 | 6.10 | 132.09 | 37.11 | 94.97 | 0.00 | 0.00 |
| October | 383.68 | 71.56 | 190.33 | 97.31 | 93.02 | 0.00 | 0.00 |
| November | 371.50 | 151.35 | 219.61 | 134.03 | 85.58 | 0.00 | 0.00 |
| December | 274.40 | 207.58 | 194.01 | 111.63 | 82.38 | 0.00 | 0.00 |
| Annual Sum or Average | 336.59 | 78.66 | 159.37 | 66.52 | 92.85 | 0.00 | 0.00 |
| Minimum of Months | 247.98 | 0.30 | 105.48 | 10.60 | 82.16 | 0.00 | 0.00 |
| Maximum of Months | 410.81 | 210.21 | 219.61 | 134.03 | 102.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 63.18 | 200.10 | 75.45 | 17.82 | 57.63 | 0.00 | 0.00 |
| February | 104.30 | 164.10 | 90.56 | 22.02 | 68.53 | 0.00 | 0.00 |
| March | 180.53 | 96.13 | 110.00 | 26.93 | 83.06 | 0.00 | 0.00 |
| April | 309.17 | 26.84 | 126.53 | 36.65 | 89.88 | 0.00 | 0.00 |
| May | 397.85 | 2.43 | 130.34 | 35.57 | 94.77 | 0.00 | 0.00 |
| June | 394.95 | 2.37 | 117.65 | 22.56 | 95.10 | 0.00 | 0.00 |
| July | 345.59 | 0.29 | 107.13 | 11.92 | 95.22 | 0.00 | 0.00 |
| August | 287.58 | 0.93 | 97.60 | 8.44 | 89.16 | 0.00 | 0.00 |
| September | 238.35 | 5.77 | 95.08 | 13.93 | 81.15 | 0.00 | 0.00 |
| October | 193.84 | 69.81 | 93.98 | 22.29 | 71.68 | 0.00 | 0.00 |
| November | 118.59 | 146.81 | 81.66 | 20.88 | 60.77 | 0.00 | 0.00 |
| December | 70.18 | 197.78 | 73.00 | 16.82 | 56.17 | 0.00 | 0.00 |
| Annual Sum or Average | 225.90 | 75.73 | 99.93 | 21.29 | 78.64 | 0.00 | 0.00 |
| Minimum of Months | 63.18 | 0.29 | 73.00 | 8.44 | 56.17 | 0.00 | 0.00 |
| Maximum of Months | 397.85 | 200.10 | 130.34 | 36.65 | 95.22 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 20.89 | 135.13 | 31.26 | 0.00 | 31.26 | 0.00 | 0.00 |
| February | 36.99 | 109.44 | 37.07 | 0.00 | 37.07 | 0.00 | 0.00 |
| March | 72.74 | 62.56 | 44.68 | 0.00 | 44.67 | 0.00 | 0.00 |
| April | 137.00 | 16.55 | 48.58 | 0.24 | 48.34 | 0.00 | 0.00 |
| May | 197.19 | 1.44 | 53.87 | 1.67 | 52.20 | 0.00 | 0.00 |
| June | 212.66 | 1.43 | 55.44 | 1.92 | 53.52 | 0.00 | 0.00 |
| July | 193.23 | 0.18 | 54.91 | 0.94 | 53.97 | 0.00 | 0.00 |
| August | 160.52 | 0.53 | 50.50 | 0.28 | 50.21 | 0.00 | 0.00 |
| September | 122.31 | 3.44 | 44.85 | 0.01 | 44.84 | 0.00 | 0.00 |
| October | 85.01 | 43.98 | 38.85 | 0.00 | 38.85 | 0.00 | 0.00 |
| November | 44.15 | 95.94 | 32.90 | 0.00 | 32.90 | 0.00 | 0.00 |
| December | 22.73 | 131.41 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Annual Sum or Average | 109.15 | 49.91 | 43.65 | 0.42 | 43.22 | 0.00 | 0.00 |
| Minimum of Months | 20.89 | 0.18 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Maximum of Months | 212.66 | 135.13 | 55.44 | 1.92 | 53.97 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 20.77 | 135.04 | 31.26 | 0.00 | 31.26 | 0.00 | 0.00 |
| February | 36.80 | 109.42 | 37.07 | 0.00 | 37.07 | 0.00 | 0.00 |
| March | 72.61 | 62.54 | 44.68 | 0.00 | 44.67 | 0.00 | 0.00 |
| April | 136.97 | 16.54 | 48.58 | 0.24 | 48.34 | 0.00 | 0.00 |
| May | 197.18 | 1.44 | 53.87 | 1.67 | 52.20 | 0.00 | 0.00 |
| June | 212.67 | 1.42 | 55.44 | 1.92 | 53.52 | 0.00 | 0.00 |
| July | 193.23 | 0.18 | 54.91 | 0.94 | 53.97 | 0.00 | 0.00 |
| August | 160.52 | 0.53 | 50.50 | 0.28 | 50.21 | 0.00 | 0.00 |
| September | 122.30 | 3.44 | 44.85 | 0.01 | 44.84 | 0.00 | 0.00 |
| October | 84.96 | 43.96 | 38.85 | 0.00 | 38.85 | 0.00 | 0.00 |
| November | 44.04 | 95.86 | 32.90 | 0.00 | 32.90 | 0.00 | 0.00 |
| December | 22.60 | 131.32 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Annual Sum or Average | 109.09 | 49.88 | 43.65 | 0.42 | 43.22 | 0.00 | 0.00 |
| Minimum of Months | 20.77 | 0.18 | 30.49 | 0.00 | 30.49 | 0.00 | 0.00 |
| Maximum of Months | 212.67 | 135.04 | 55.44 | 1.92 | 53.97 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 205.18 | 133.40 | 141.32 | 85.53 | 55.78 | 0.00 | 0.00 |
| February | 215.11 | 108.24 | 136.39 | 76.29 | 60.10 | 0.00 | 0.00 |
| March | 212.05 | 62.71 | 112.65 | 48.13 | 64.52 | 0.00 | 0.00 |
| April | 218.51 | 17.46 | 83.64 | 25.35 | 58.30 | 0.00 | 0.00 |
| May | 210.41 | 1.40 | 58.63 | 4.55 | 54.08 | 0.00 | 0.00 |
| June | 209.06 | 1.45 | 53.59 | 1.09 | 52.49 | 0.00 | 0.00 |
| July | 195.66 | 0.18 | 55.56 | 0.62 | 54.94 | 0.00 | 0.00 |
| August | 177.93 | 0.55 | 58.38 | 2.45 | 55.93 | 0.00 | 0.00 |
| September | 199.44 | 3.67 | 81.86 | 23.19 | 58.66 | 0.00 | 0.00 |
| October | 276.27 | 44.23 | 135.20 | 75.02 | 60.18 | 0.00 | 0.00 |
| November | 298.82 | 95.07 | 170.86 | 113.15 | 57.71 | 0.00 | 0.00 |
| December | 228.94 | 131.19 | 151.51 | 94.81 | 56.70 | 0.00 | 0.00 |
| Annual Sum or Average | 220.54 | 49.71 | 103.09 | 45.65 | 57.44 | 0.00 | 0.00 |
| Minimum of Months | 177.93 | 0.18 | 53.59 | 0.62 | 52.49 | 0.00 | 0.00 |
| Maximum of Months | 298.82 | 133.40 | 170.86 | 113.15 | 64.52 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 205.04 | 133.36 | 141.32 | 85.53 | 55.78 | 0.00 | 0.00 |
| February | 214.96 | 108.21 | 136.39 | 76.29 | 60.10 | 0.00 | 0.00 |
| March | 211.96 | 62.69 | 112.65 | 48.13 | 64.52 | 0.00 | 0.00 |
| April | 218.49 | 17.45 | 83.64 | 25.35 | 58.30 | 0.00 | 0.00 |
| May | 210.40 | 1.40 | 58.63 | 4.55 | 54.08 | 0.00 | 0.00 |
| June | 209.07 | 1.44 | 53.59 | 1.09 | 52.49 | 0.00 | 0.00 |
| July | 195.66 | 0.18 | 55.56 | 0.62 | 54.94 | 0.00 | 0.00 |
| August | 177.93 | 0.55 | 58.38 | 2.45 | 55.93 | 0.00 | 0.00 |
| September | 199.44 | 3.66 | 81.86 | 23.19 | 58.66 | 0.00 | 0.00 |
| October | 276.24 | 44.22 | 135.20 | 75.02 | 60.18 | 0.00 | 0.00 |
| November | 298.75 | 95.03 | 170.86 | 113.15 | 57.71 | 0.00 | 0.00 |
| December | 228.82 | 131.15 | 151.51 | 94.81 | 56.70 | 0.00 | 0.00 |
| Annual Sum or Average | 220.49 | 49.69 | 103.09 | 45.65 | 57.44 | 0.00 | 0.00 |
| Minimum of Months | 177.93 | 0.18 | 53.59 | 0.62 | 52.49 | 0.00 | 0.00 |
| Maximum of Months | 298.75 | 133.36 | 170.86 | 113.15 | 64.52 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 11.56 | 21.61 | 10.60 | 4.28 | 6.33 | 0.00 | 0.00 |
| February | 16.98 | 17.81 | 12.84 | 5.28 | 7.55 | 0.00 | 0.00 |
| March | 26.06 | 10.81 | 15.67 | 6.46 | 9.21 | 0.00 | 0.00 |
| April | 40.07 | 3.71 | 18.70 | 8.74 | 9.97 | 0.00 | 0.00 |
| May | 45.86 | 0.59 | 18.35 | 8.14 | 10.21 | 0.00 | 0.00 |
| June | 41.14 | 0.53 | 14.93 | 4.95 | 9.98 | 0.00 | 0.00 |
| July | 33.64 | 0.11 | 12.53 | 2.63 | 9.90 | 0.00 | 0.00 |
| August | 27.91 | 0.44 | 11.30 | 1.96 | 9.35 | 0.00 | 0.00 |
| September | 26.00 | 1.64 | 12.05 | 3.34 | 8.71 | 0.00 | 0.00 |
| October | 25.53 | 8.32 | 13.23 | 5.35 | 7.88 | 0.00 | 0.00 |
| November | 17.93 | 15.88 | 11.70 | 5.01 | 6.69 | 0.00 | 0.00 |
| December | 12.01 | 21.50 | 10.20 | 4.04 | 6.16 | 0.00 | 0.00 |
| Annual Sum or Average | 27.09 | 8.54 | 13.51 | 5.01 | 8.50 | 0.00 | 0.00 |
| Minimum of Months | 11.56 | 0.11 | 10.20 | 1.96 | 6.16 | 0.00 | 0.00 |
| Maximum of Months | 45.86 | 21.61 | 18.70 | 8.74 | 10.21 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 31.58 | 69.19 | 31.58 | 12.74 | 18.85 | 0.00 | 0.00 |
| February | 48.89 | 55.84 | 38.23 | 15.74 | 22.49 | 0.00 | 0.00 |
| March | 75.94 | 34.67 | 46.68 | 19.25 | 27.44 | 0.00 | 0.00 |
| April | 114.25 | 14.35 | 55.71 | 26.02 | 29.69 | 0.00 | 0.00 |
| May | 127.51 | 4.01 | 54.65 | 24.23 | 30.42 | 0.00 | 0.00 |
| June | 112.26 | 3.10 | 44.46 | 14.75 | 29.71 | 0.00 | 0.00 |
| July | 90.20 | 1.39 | 37.32 | 7.84 | 29.48 | 0.00 | 0.00 |
| August | 75.30 | 3.49 | 33.66 | 5.83 | 27.83 | 0.00 | 0.00 |
| September | 71.44 | 9.53 | 35.90 | 9.95 | 25.95 | 0.00 | 0.00 |
| October | 71.25 | 30.41 | 39.40 | 15.93 | 23.47 | 0.00 | 0.00 |
| November | 49.73 | 52.81 | 34.84 | 14.92 | 19.92 | 0.00 | 0.00 |
| December | 31.59 | 71.07 | 30.37 | 12.02 | 18.35 | 0.00 | 0.00 |
| Annual Sum or Average | 75.08 | 29.04 | 40.22 | 14.91 | 25.31 | 0.00 | 0.00 |
| Minimum of Months | 31.58 | 1.39 | 30.37 | 5.83 | 18.35 | 0.00 | 0.00 |
| Maximum of Months | 127.51 | 71.07 | 55.71 | 26.02 | 30.42 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
| January | 9.62 | 24.79 | 10.60 | 4.28 | 6.33 | 0.00 | 0.00 |
| February | 15.66 | 19.76 | 12.84 | 5.28 | 7.55 | 0.00 | 0.00 |
| March | 25.67 | 11.41 | 15.67 | 6.46 | 9.21 | 0.00 | 0.00 |
| April | 40.60 | 3.87 | 18.70 | 8.74 | 9.97 | 0.00 | 0.00 |
| May | 46.96 | 0.60 | 18.35 | 8.14 | 10.21 | 0.00 | 0.00 |
| June | 42.41 | 0.51 | 14.93 | 4.95 | 9.98 | 0.00 | 0.00 |
| July | 34.85 | 0.10 | 12.53 | 2.63 | 9.90 | 0.00 | 0.00 |
| August | 28.87 | 0.41 | 11.30 | 1.96 | 9.35 | 0.00 | 0.00 |
| September | 26.56 | 1.62 | 12.05 | 3.34 | 8.71 | 0.00 | 0.00 |
| October | 25.45 | 8.72 | 13.23 | 5.35 | 7.88 | 0.00 | 0.00 |
| November | 17.04 | 17.15 | 11.70 | 5.01 | 6.69 | 0.00 | 0.00 |
| December | 10.15 | 24.64 | 10.20 | 4.04 | 6.16 | 0.00 | 0.00 |
| Annual Sum or Average | 27.03 | 9.42 | 13.51 | 5.01 | 8.50 | 0.00 | 0.00 |
| Minimum of Months | 9.62 | 0.10 | 10.20 | 1.96 | 6.16 | 0.00 | 0.00 |
| Maximum of Months | 46.96 | 24.79 | 18.70 | 8.74 | 10.21 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.663076E+09 | 0.643751E+09 | 0.493922E+09 | 0.273962E+09 | 0.219960E+09 | 0.00 | 0.00 |
| February | 0.686018E+09 | 0.452715E+09 | 0.449047E+09 | 0.228381E+09 | 0.220666E+09 | 0.00 | 0.00 |
| March | 0.885920E+09 | 0.281346E+09 | 0.473584E+09 | 0.197970E+09 | 0.275614E+09 | 0.00 | 0.00 |
| April | 0.103781E+10 | 78842422.61 | 0.417829E+09 | 0.159793E+09 | 0.258036E+09 | 0.00 | 0.00 |
| May | 0.110650E+10 | 7662991.94 | 0.353800E+09 | 95520699.22 | 0.258280E+09 | 0.00 | 0.00 |
| June | 0.106322E+10 | 7177946.94 | 0.318515E+09 | 72950561.27 | 0.245564E+09 | 0.00 | 0.00 |
| July | 0.926629E+09 | 1151425.61 | 0.286043E+09 | 28271683.34 | 0.257771E+09 | 0.00 | 0.00 |
| August | 0.814674E+09 | 4635967.30 | 0.282190E+09 | 28639824.35 | 0.253550E+09 | 0.00 | 0.00 |
| September | 0.825006E+09 | 25326598.21 | 0.346672E+09 | 99914509.96 | 0.246758E+09 | 0.00 | 0.00 |
| October | 0.103275E+10 | 0.221657E+09 | 0.506391E+09 | 0.258326E+09 | 0.248065E+09 | 0.00 | 0.00 |
| November | 0.975035E+09 | 0.438806E+09 | 0.569149E+09 | 0.347077E+09 | 0.222073E+09 | 0.00 | 0.00 |
| December | 0.722442E+09 | 0.634925E+09 | 0.517616E+09 | 0.296639E+09 | 0.220977E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.107391E+11 | 0.279800E+10 | 0.501476E+10 | 0.208744E+10 | 0.292731E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.663076E+09 | 1151425.61 | 0.282190E+09 | 28271683.34 | 0.219960E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.110650E+10 | 0.643751E+09 | 0.569149E+09 | 0.347077E+09 | 0.275614E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.183904E+09 | 0.637575E+09 | 0.199145E+09 | 44877482.19 | 0.154267E+09 | 0.00 | 0.00 |
| February | 0.260513E+09 | 0.448335E+09 | 0.208755E+09 | 43815973.67 | 0.164939E+09 | 0.00 | 0.00 |
| March | 0.514663E+09 | 0.276082E+09 | 0.291528E+09 | 69077107.83 | 0.222450E+09 | 0.00 | 0.00 |
| April | 0.826297E+09 | 74665731.86 | 0.326946E+09 | 94722085.77 | 0.232224E+09 | 0.00 | 0.00 |
| May | 0.107136E+10 | 7684050.52 | 0.341040E+09 | 87794501.12 | 0.253245E+09 | 0.00 | 0.00 |
| June | 0.107228E+10 | 7189550.34 | 0.323325E+09 | 75105750.18 | 0.248220E+09 | 0.00 | 0.00 |
| July | 0.920405E+09 | 1168470.31 | 0.284293E+09 | 29143228.13 | 0.255150E+09 | 0.00 | 0.00 |
| August | 0.768039E+09 | 4562200.78 | 0.261075E+09 | 22838960.91 | 0.238236E+09 | 0.00 | 0.00 |
| September | 0.624194E+09 | 23698833.34 | 0.250742E+09 | 39813159.56 | 0.210929E+09 | 0.00 | 0.00 |
| October | 0.520735E+09 | 0.217750E+09 | 0.248314E+09 | 57399869.82 | 0.190914E+09 | 0.00 | 0.00 |
| November | 0.316541E+09 | 0.444285E+09 | 0.211570E+09 | 53795546.57 | 0.157774E+09 | 0.00 | 0.00 |
| December | 0.172020E+09 | 0.652501E+09 | 0.193479E+09 | 42700072.59 | 0.150779E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.725095E+10 | 0.279550E+10 | 0.314021E+10 | 0.661084E+09 | 0.247913E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.172020E+09 | 1168470.31 | 0.193479E+09 | 22838960.91 | 0.150779E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.107228E+10 | 0.652501E+09 | 0.341040E+09 | 94722085.77 | 0.255150E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.664591E+09 | 0.630501E+09 | 0.496870E+09 | 0.276825E+09 | 0.220045E+09 | 0.00 | 0.00 |
| February | 0.690589E+09 | 0.466869E+09 | 0.459365E+09 | 0.237840E+09 | 0.221526E+09 | 0.00 | 0.00 |
| March | 0.852289E+09 | 0.331262E+09 | 0.476674E+09 | 0.201032E+09 | 0.275642E+09 | 0.00 | 0.00 |
| April | 0.944843E+09 | 0.150106E+09 | 0.418850E+09 | 0.160074E+09 | 0.258777E+09 | 0.00 | 0.00 |
| May | 0.967322E+09 | 52959325.32 | 0.361865E+09 | 0.103006E+09 | 0.258859E+09 | 0.00 | 0.00 |
| June | 0.865794E+09 | 40223342.82 | 0.300144E+09 | 56311729.92 | 0.243833E+09 | 0.00 | 0.00 |
| July | 0.745546E+09 | 26791023.72 | 0.288699E+09 | 31043005.31 | 0.257656E+09 | 0.00 | 0.00 |
| August | 0.677163E+09 | 57630200.82 | 0.282522E+09 | 28402636.47 | 0.254120E+09 | 0.00 | 0.00 |
| September | 0.721757E+09 | 0.123331E+09 | 0.342368E+09 | 96200632.37 | 0.246168E+09 | 0.00 | 0.00 |
| October | 0.979880E+09 | 0.324246E+09 | 0.509779E+09 | 0.260636E+09 | 0.249143E+09 | 0.00 | 0.00 |
| November | 0.941807E+09 | 0.501261E+09 | 0.569232E+09 | 0.347409E+09 | 0.221823E+09 | 0.00 | 0.00 |
| December | 0.722470E+09 | 0.649105E+09 | 0.519647E+09 | 0.298997E+09 | 0.220650E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.977405E+10 | 0.335428E+10 | 0.502602E+10 | 0.209778E+10 | 0.292824E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.664591E+09 | 26791023.72 | 0.282522E+09 | 28402636.47 | 0.220045E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.979880E+09 | 0.649105E+09 | 0.569232E+09 | 0.347409E+09 | 0.275642E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.148878E+09 | 0.598998E+09 | 0.202093E+09 | 47740397.38 | 0.154352E+09 | 0.00 | 0.00 |
| February | 0.249520E+09 | 0.422617E+09 | 0.219074E+09 | 53274837.78 | 0.165799E+09 | 0.00 | 0.00 |
| March | 0.501155E+09 | 0.259628E+09 | 0.294618E+09 | 72139654.12 | 0.222478E+09 | 0.00 | 0.00 |
| April | 0.824181E+09 | 71889000.02 | 0.327968E+09 | 95002374.23 | 0.232965E+09 | 0.00 | 0.00 |
| May | 0.108502E+10 | 7407999.92 | 0.349104E+09 | 95279844.41 | 0.253825E+09 | 0.00 | 0.00 |
| June | 0.103702E+10 | 7085368.51 | 0.304955E+09 | 58466918.84 | 0.246488E+09 | 0.00 | 0.00 |
| July | 0.927683E+09 | 1115989.07 | 0.286950E+09 | 31914550.09 | 0.255035E+09 | 0.00 | 0.00 |
| August | 0.767949E+09 | 4452070.98 | 0.261407E+09 | 22601773.03 | 0.238806E+09 | 0.00 | 0.00 |
| September | 0.615173E+09 | 22903541.28 | 0.246438E+09 | 36099281.96 | 0.210338E+09 | 0.00 | 0.00 |
| October | 0.516107E+09 | 0.209008E+09 | 0.251703E+09 | 59709845.47 | 0.191993E+09 | 0.00 | 0.00 |
| November | 0.292700E+09 | 0.423572E+09 | 0.211653E+09 | 54128288.04 | 0.157525E+09 | 0.00 | 0.00 |
| December | 0.150521E+09 | 0.626785E+09 | 0.195510E+09 | 45058622.97 | 0.150452E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.711591E+10 | 0.265546E+10 | 0.315147E+10 | 0.671416E+09 | 0.248006E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.148878E+09 | 1115989.07 | 0.195510E+09 | 22601773.03 | 0.150452E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.108502E+10 | 0.626785E+09 | 0.349104E+09 | 95279844.41 | 0.255035E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 44092343.56 | 0.410391E+09 | 83720776.50 | 0.00 | 83720776.50 | 0.00 | 0.00 |
| February | 86136546.68 | 0.283458E+09 | 89671001.12 | 0.00 | 89671001.12 | 0.00 | 0.00 |
| March | 0.201257E+09 | 0.169355E+09 | 0.119662E+09 | 11416.56 | 0.119651E+09 | 0.00 | 0.00 |
| April | 0.364007E+09 | 44380407.81 | 0.125924E+09 | 626385.41 | 0.125297E+09 | 0.00 | 0.00 |
| May | 0.535867E+09 | 4281845.17 | 0.144278E+09 | 4464536.23 | 0.139814E+09 | 0.00 | 0.00 |
| June | 0.557154E+09 | 4073757.44 | 0.143703E+09 | 4986643.04 | 0.138717E+09 | 0.00 | 0.00 |
| July | 0.519014E+09 | 616544.47 | 0.147069E+09 | 2528891.87 | 0.144540E+09 | 0.00 | 0.00 |
| August | 0.429361E+09 | 2201623.83 | 0.135248E+09 | 754189.90 | 0.134494E+09 | 0.00 | 0.00 |
| September | 0.315520E+09 | 12318374.68 | 0.116241E+09 | 14758.11 | 0.116226E+09 | 0.00 | 0.00 |
| October | 0.225864E+09 | 0.129000E+09 | 0.104047E+09 | 0.00 | 0.104047E+09 | 0.00 | 0.00 |
| November | 0.107936E+09 | 0.270408E+09 | 85286195.69 | 0.00 | 85286195.69 | 0.00 | 0.00 |
| December | 44343569.13 | 0.413186E+09 | 81671108.11 | 0.00 | 81671108.11 | 0.00 | 0.00 |
| Annual Sum or Average | 0.343055E+10 | 0.174367E+10 | 0.137652E+10 | 13386821.13 | 0.136313E+10 | 0.00 | 0.00 |
| Minimum of Months | 44092343.56 | 616544.47 | 81671108.11 | 0.00 | 81671108.11 | 0.00 | 0.00 |
| Maximum of Months | 0.557154E+09 | 0.413186E+09 | 0.147069E+09 | 4986643.04 | 0.144540E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 43976376.29 | 0.410493E+09 | 83720776.50 | 0.00 | 83720776.50 | 0.00 | 0.00 |
| February | 85967963.45 | 0.283627E+09 | 89671001.12 | 0.00 | 89671001.12 | 0.00 | 0.00 |
| March | 0.201134E+09 | 0.169390E+09 | 0.119662E+09 | 11416.56 | 0.119651E+09 | 0.00 | 0.00 |
| April | 0.363965E+09 | 44377014.30 | 0.125924E+09 | 626385.41 | 0.125297E+09 | 0.00 | 0.00 |
| May | 0.535845E+09 | 4279275.77 | 0.144278E+09 | 4464536.23 | 0.139814E+09 | 0.00 | 0.00 |
| June | 0.557177E+09 | 4070971.61 | 0.143703E+09 | 4986643.04 | 0.138717E+09 | 0.00 | 0.00 |
| July | 0.519011E+09 | 616448.01 | 0.147069E+09 | 2528891.87 | 0.144540E+09 | 0.00 | 0.00 |
| August | 0.429357E+09 | 2202183.30 | 0.135248E+09 | 754189.90 | 0.134494E+09 | 0.00 | 0.00 |
| September | 0.315520E+09 | 12311242.74 | 0.116241E+09 | 14758.11 | 0.116226E+09 | 0.00 | 0.00 |
| October | 0.225821E+09 | 0.128999E+09 | 0.104047E+09 | 0.00 | 0.104047E+09 | 0.00 | 0.00 |
| November | 0.107851E+09 | 0.270422E+09 | 85286195.69 | 0.00 | 85286195.69 | 0.00 | 0.00 |
| December | 44262195.80 | 0.413211E+09 | 81671108.11 | 0.00 | 81671108.11 | 0.00 | 0.00 |
| Annual Sum or Average | 0.342989E+10 | 0.174400E+10 | 0.137652E+10 | 13386821.13 | 0.136313E+10 | 0.00 | 0.00 |
| Minimum of Months | 43976376.29 | 616448.01 | 81671108.11 | 0.00 | 81671108.11 | 0.00 | 0.00 |
| Maximum of Months | 0.557177E+09 | 0.413211E+09 | 0.147069E+09 | 4986643.04 | 0.144540E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.542540E+09 | 0.392361E+09 | 0.378498E+09 | 0.229085E+09 | 0.149413E+09 | 0.00 | 0.00 |
| February | 0.524533E+09 | 0.276360E+09 | 0.329963E+09 | 0.184565E+09 | 0.145398E+09 | 0.00 | 0.00 |
| March | 0.578066E+09 | 0.171634E+09 | 0.301718E+09 | 0.128904E+09 | 0.172815E+09 | 0.00 | 0.00 |
| April | 0.577973E+09 | 47592517.88 | 0.216806E+09 | 65697605.51 | 0.151109E+09 | 0.00 | 0.00 |
| May | 0.571412E+09 | 4256705.13 | 0.157039E+09 | 12190734.33 | 0.144848E+09 | 0.00 | 0.00 |
| June | 0.547817E+09 | 4110979.56 | 0.138893E+09 | 2831454.13 | 0.136062E+09 | 0.00 | 0.00 |
| July | 0.525063E+09 | 617439.42 | 0.148818E+09 | 1657347.09 | 0.147161E+09 | 0.00 | 0.00 |
| August | 0.476384E+09 | 2293547.29 | 0.156363E+09 | 6555053.33 | 0.149808E+09 | 0.00 | 0.00 |
| September | 0.518211E+09 | 13431179.45 | 0.212171E+09 | 60116108.52 | 0.152055E+09 | 0.00 | 0.00 |
| October | 0.742913E+09 | 0.130892E+09 | 0.362124E+09 | 0.200926E+09 | 0.161198E+09 | 0.00 | 0.00 |
| November | 0.776022E+09 | 0.263183E+09 | 0.442866E+09 | 0.293281E+09 | 0.149585E+09 | 0.00 | 0.00 |
| December | 0.605862E+09 | 0.384221E+09 | 0.405808E+09 | 0.253939E+09 | 0.151870E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.698680E+10 | 0.169095E+10 | 0.325107E+10 | 0.143975E+10 | 0.181132E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.476384E+09 | 617439.42 | 0.138893E+09 | 1657347.09 | 0.136062E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.776022E+09 | 0.392361E+09 | 0.442866E+09 | 0.293281E+09 | 0.172815E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.542794E+09 | 0.391773E+09 | 0.378498E+09 | 0.229085E+09 | 0.149413E+09 | 0.00 | 0.00 |
| February | 0.524106E+09 | 0.276913E+09 | 0.329963E+09 | 0.184565E+09 | 0.145398E+09 | 0.00 | 0.00 |
| March | 0.576780E+09 | 0.173206E+09 | 0.301718E+09 | 0.128904E+09 | 0.172815E+09 | 0.00 | 0.00 |
| April | 0.575361E+09 | 49187300.08 | 0.216806E+09 | 65697605.51 | 0.151109E+09 | 0.00 | 0.00 |
| May | 0.567123E+09 | 4643933.66 | 0.157039E+09 | 12190734.33 | 0.144848E+09 | 0.00 | 0.00 |
| June | 0.543680E+09 | 4426386.44 | 0.138893E+09 | 2831454.13 | 0.136062E+09 | 0.00 | 0.00 |
| July | 0.520366E+09 | 675281.12 | 0.148818E+09 | 1657347.09 | 0.147161E+09 | 0.00 | 0.00 |
| August | 0.472331E+09 | 2666058.33 | 0.156363E+09 | 6555053.33 | 0.149808E+09 | 0.00 | 0.00 |
| September | 0.515133E+09 | 14839396.04 | 0.212171E+09 | 60116108.52 | 0.152055E+09 | 0.00 | 0.00 |
| October | 0.740970E+09 | 0.133470E+09 | 0.362124E+09 | 0.200926E+09 | 0.161198E+09 | 0.00 | 0.00 |
| November | 0.774840E+09 | 0.264988E+09 | 0.442866E+09 | 0.293281E+09 | 0.149585E+09 | 0.00 | 0.00 |
| December | 0.605592E+09 | 0.384501E+09 | 0.405808E+09 | 0.253939E+09 | 0.151870E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.695908E+10 | 0.170129E+10 | 0.325107E+10 | 0.143975E+10 | 0.181132E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.472331E+09 | 675281.12 | 0.138893E+09 | 1657347.09 | 0.136062E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.774840E+09 | 0.391773E+09 | 0.442866E+09 | 0.293281E+09 | 0.172815E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.652740E+09 | 0.653137E+09 | 0.493922E+09 | 0.273962E+09 | 0.219960E+09 | 0.00 | 0.00 |
| February | 0.673931E+09 | 0.465086E+09 | 0.449047E+09 | 0.228381E+09 | 0.220666E+09 | 0.00 | 0.00 |
| March | 0.874440E+09 | 0.290281E+09 | 0.473584E+09 | 0.197970E+09 | 0.275614E+09 | 0.00 | 0.00 |
| April | 0.103399E+10 | 79984444.93 | 0.417829E+09 | 0.159793E+09 | 0.258036E+09 | 0.00 | 0.00 |
| May | 0.111442E+10 | 7177001.49 | 0.353800E+09 | 95520699.22 | 0.258280E+09 | 0.00 | 0.00 |
| June | 0.107768E+10 | 6379671.86 | 0.318515E+09 | 72950561.27 | 0.245564E+09 | 0.00 | 0.00 |
| July | 0.949710E+09 | 869667.79 | 0.286043E+09 | 28271683.34 | 0.257771E+09 | 0.00 | 0.00 |
| August | 0.838859E+09 | 2708638.89 | 0.282190E+09 | 28639824.35 | 0.253550E+09 | 0.00 | 0.00 |
| September | 0.842884E+09 | 17615899.37 | 0.346672E+09 | 99914509.96 | 0.246758E+09 | 0.00 | 0.00 |
| October | 0.104190E+10 | 0.206955E+09 | 0.506391E+09 | 0.258326E+09 | 0.248065E+09 | 0.00 | 0.00 |
| November | 0.977827E+09 | 0.429368E+09 | 0.569149E+09 | 0.347077E+09 | 0.222073E+09 | 0.00 | 0.00 |
| December | 0.719972E+09 | 0.632171E+09 | 0.517616E+09 | 0.296639E+09 | 0.220977E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.107983E+11 | 0.279173E+10 | 0.501476E+10 | 0.208744E+10 | 0.292731E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.652740E+09 | 869667.79 | 0.282190E+09 | 28271683.34 | 0.219960E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.111442E+10 | 0.653137E+09 | 0.569149E+09 | 0.347077E+09 | 0.275614E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.177340E+09 | 0.653447E+09 | 0.199145E+09 | 44877482.19 | 0.154267E+09 | 0.00 | 0.00 |
| February | 0.248101E+09 | 0.472388E+09 | 0.208755E+09 | 43815973.67 | 0.164939E+09 | 0.00 | 0.00 |
| March | 0.503147E+09 | 0.288956E+09 | 0.291528E+09 | 69077107.83 | 0.222450E+09 | 0.00 | 0.00 |
| April | 0.823048E+09 | 76516409.42 | 0.326946E+09 | 94722085.77 | 0.232224E+09 | 0.00 | 0.00 |
| May | 0.107937E+10 | 7209628.71 | 0.341040E+09 | 87794501.12 | 0.253245E+09 | 0.00 | 0.00 |
| June | 0.108699E+10 | 6361634.76 | 0.323325E+09 | 75105750.18 | 0.248220E+09 | 0.00 | 0.00 |
| July | 0.943356E+09 | 866137.32 | 0.284293E+09 | 29143228.13 | 0.255150E+09 | 0.00 | 0.00 |
| August | 0.792587E+09 | 2633538.00 | 0.261075E+09 | 22838960.91 | 0.238236E+09 | 0.00 | 0.00 |
| September | 0.643602E+09 | 16480650.79 | 0.250742E+09 | 39813159.56 | 0.210929E+09 | 0.00 | 0.00 |
| October | 0.531636E+09 | 0.204165E+09 | 0.248314E+09 | 57399869.82 | 0.190914E+09 | 0.00 | 0.00 |
| November | 0.321986E+09 | 0.435204E+09 | 0.211570E+09 | 53795546.57 | 0.157774E+09 | 0.00 | 0.00 |
| December | 0.175398E+09 | 0.643914E+09 | 0.193479E+09 | 42700072.59 | 0.150779E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.732656E+10 | 0.280814E+10 | 0.314021E+10 | 0.661084E+09 | 0.247913E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.175398E+09 | 866137.32 | 0.193479E+09 | 22838960.91 | 0.150779E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.108699E+10 | 0.653447E+09 | 0.341040E+09 | 94722085.77 | 0.255150E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.642082E+09 | 0.636855E+09 | 0.496870E+09 | 0.276825E+09 | 0.220045E+09 | 0.00 | 0.00 |
| February | 0.678204E+09 | 0.452624E+09 | 0.459365E+09 | 0.237840E+09 | 0.221526E+09 | 0.00 | 0.00 |
| March | 0.864151E+09 | 0.276655E+09 | 0.476674E+09 | 0.201032E+09 | 0.275642E+09 | 0.00 | 0.00 |
| April | 0.103092E+10 | 76087216.04 | 0.418850E+09 | 0.160074E+09 | 0.258777E+09 | 0.00 | 0.00 |
| May | 0.112767E+10 | 6827147.43 | 0.361865E+09 | 0.103006E+09 | 0.258859E+09 | 0.00 | 0.00 |
| June | 0.104229E+10 | 6316066.02 | 0.300144E+09 | 56311729.92 | 0.243833E+09 | 0.00 | 0.00 |
| July | 0.957461E+09 | 845141.48 | 0.288699E+09 | 31043005.31 | 0.257656E+09 | 0.00 | 0.00 |
| August | 0.838726E+09 | 2638735.84 | 0.282522E+09 | 28402636.47 | 0.254120E+09 | 0.00 | 0.00 |
| September | 0.834131E+09 | 17051086.19 | 0.342368E+09 | 96200632.37 | 0.246168E+09 | 0.00 | 0.00 |
| October | 0.104109E+10 | 0.201753E+09 | 0.509779E+09 | 0.260636E+09 | 0.249143E+09 | 0.00 | 0.00 |
| November | 0.965277E+09 | 0.419767E+09 | 0.569232E+09 | 0.347409E+09 | 0.221823E+09 | 0.00 | 0.00 |
| December | 0.715286E+09 | 0.623447E+09 | 0.519647E+09 | 0.298997E+09 | 0.220650E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.107373E+11 | 0.272087E+10 | 0.502602E+10 | 0.209778E+10 | 0.292824E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.642082E+09 | 845141.48 | 0.282522E+09 | 28402636.47 | 0.220045E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.112767E+10 | 0.636855E+09 | 0.569232E+09 | 0.347409E+09 | 0.275642E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.141502E+09 | 0.614244E+09 | 0.202093E+09 | 47740397.38 | 0.154352E+09 | 0.00 | 0.00 |
| February | 0.235933E+09 | 0.444693E+09 | 0.219074E+09 | 53274837.78 | 0.165799E+09 | 0.00 | 0.00 |
| March | 0.488107E+09 | 0.271334E+09 | 0.294618E+09 | 72139654.12 | 0.222478E+09 | 0.00 | 0.00 |
| April | 0.820692E+09 | 73496066.98 | 0.327968E+09 | 95002374.23 | 0.232965E+09 | 0.00 | 0.00 |
| May | 0.109272E+10 | 6938351.02 | 0.349104E+09 | 95279844.41 | 0.253825E+09 | 0.00 | 0.00 |
| June | 0.105158E+10 | 6267666.72 | 0.304955E+09 | 58466918.84 | 0.246488E+09 | 0.00 | 0.00 |
| July | 0.951114E+09 | 842581.21 | 0.286950E+09 | 31914550.09 | 0.255035E+09 | 0.00 | 0.00 |
| August | 0.792461E+09 | 2580876.45 | 0.261407E+09 | 22601773.03 | 0.238806E+09 | 0.00 | 0.00 |
| September | 0.634842E+09 | 15903771.30 | 0.246438E+09 | 36099281.96 | 0.210338E+09 | 0.00 | 0.00 |
| October | 0.527643E+09 | 0.196219E+09 | 0.251703E+09 | 59709845.47 | 0.191993E+09 | 0.00 | 0.00 |
| November | 0.298396E+09 | 0.414050E+09 | 0.211653E+09 | 54128288.04 | 0.157525E+09 | 0.00 | 0.00 |
| December | 0.153819E+09 | 0.618629E+09 | 0.195510E+09 | 45058622.97 | 0.150452E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.718881E+10 | 0.266520E+10 | 0.315147E+10 | 0.671416E+09 | 0.248006E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.141502E+09 | 842581.21 | 0.195510E+09 | 22601773.03 | 0.150452E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.109272E+10 | 0.618629E+09 | 0.349104E+09 | 95279844.41 | 0.255035E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 40391471.20 | 0.423002E+09 | 83720776.50 | 0.00 | 83720776.50 | 0.00 | 0.00 |
| February | 81362766.14 | 0.294383E+09 | 89671001.12 | 0.00 | 89671001.12 | 0.00 | 0.00 |
| March | 0.196994E+09 | 0.174595E+09 | 0.119662E+09 | 11416.56 | 0.119651E+09 | 0.00 | 0.00 |
| April | 0.364492E+09 | 44588672.66 | 0.125924E+09 | 626385.41 | 0.125297E+09 | 0.00 | 0.00 |
| May | 0.542042E+09 | 3943382.98 | 0.144278E+09 | 4464536.23 | 0.139814E+09 | 0.00 | 0.00 |
| June | 0.565965E+09 | 3615719.11 | 0.143703E+09 | 4986643.04 | 0.138717E+09 | 0.00 | 0.00 |
| July | 0.531232E+09 | 500450.15 | 0.147069E+09 | 2528891.87 | 0.144540E+09 | 0.00 | 0.00 |
| August | 0.441843E+09 | 1404123.15 | 0.135248E+09 | 754189.90 | 0.134494E+09 | 0.00 | 0.00 |
| September | 0.325795E+09 | 9154602.57 | 0.116241E+09 | 14758.11 | 0.116226E+09 | 0.00 | 0.00 |
| October | 0.231706E+09 | 0.122377E+09 | 0.104047E+09 | 0.00 | 0.104047E+09 | 0.00 | 0.00 |
| November | 0.110757E+09 | 0.265279E+09 | 85286195.69 | 0.00 | 85286195.69 | 0.00 | 0.00 |
| December | 44779944.41 | 0.412243E+09 | 81671108.11 | 0.00 | 81671108.11 | 0.00 | 0.00 |
| Annual Sum or Average | 0.347736E+10 | 0.175509E+10 | 0.137652E+10 | 13386821.13 | 0.136313E+10 | 0.00 | 0.00 |
| Minimum of Months | 40391471.20 | 500450.15 | 81671108.11 | 0.00 | 81671108.11 | 0.00 | 0.00 |
| Maximum of Months | 0.565965E+09 | 0.423002E+09 | 0.147069E+09 | 4986643.04 | 0.144540E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 40249076.44 | 0.423120E+09 | 83720776.50 | 0.00 | 83720776.50 | 0.00 | 0.00 |
| February | 81200321.82 | 0.294487E+09 | 89671001.12 | 0.00 | 89671001.12 | 0.00 | 0.00 |
| March | 0.196853E+09 | 0.174629E+09 | 0.119662E+09 | 11416.56 | 0.119651E+09 | 0.00 | 0.00 |
| April | 0.364452E+09 | 44581996.11 | 0.125924E+09 | 626385.41 | 0.125297E+09 | 0.00 | 0.00 |
| May | 0.542024E+09 | 3940531.96 | 0.144278E+09 | 4464536.23 | 0.139814E+09 | 0.00 | 0.00 |
| June | 0.565982E+09 | 3613370.98 | 0.143703E+09 | 4986643.04 | 0.138717E+09 | 0.00 | 0.00 |
| July | 0.531229E+09 | 500397.59 | 0.147069E+09 | 2528891.87 | 0.144540E+09 | 0.00 | 0.00 |
| August | 0.441839E+09 | 1404449.60 | 0.135248E+09 | 754189.90 | 0.134494E+09 | 0.00 | 0.00 |
| September | 0.325794E+09 | 9148684.93 | 0.116241E+09 | 14758.11 | 0.116226E+09 | 0.00 | 0.00 |
| October | 0.231655E+09 | 0.122373E+09 | 0.104047E+09 | 0.00 | 0.104047E+09 | 0.00 | 0.00 |
| November | 0.110662E+09 | 0.265269E+09 | 85286195.69 | 0.00 | 85286195.69 | 0.00 | 0.00 |
| December | 44670146.43 | 0.412300E+09 | 81671108.11 | 0.00 | 81671108.11 | 0.00 | 0.00 |
| Annual Sum or Average | 0.347661E+10 | 0.175537E+10 | 0.137652E+10 | 13386821.13 | 0.136313E+10 | 0.00 | 0.00 |
| Minimum of Months | 40249076.44 | 500397.59 | 81671108.11 | 0.00 | 81671108.11 | 0.00 | 0.00 |
| Maximum of Months | 0.565982E+09 | 0.423120E+09 | 0.147069E+09 | 4986643.04 | 0.144540E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.536119E+09 | 0.397090E+09 | 0.378498E+09 | 0.229085E+09 | 0.149413E+09 | 0.00 | 0.00 |
| February | 0.518296E+09 | 0.281481E+09 | 0.329963E+09 | 0.184565E+09 | 0.145398E+09 | 0.00 | 0.00 |
| March | 0.572999E+09 | 0.174594E+09 | 0.301718E+09 | 0.128904E+09 | 0.172815E+09 | 0.00 | 0.00 |
| April | 0.577411E+09 | 47293770.03 | 0.216806E+09 | 65697605.51 | 0.151109E+09 | 0.00 | 0.00 |
| May | 0.577590E+09 | 3876255.82 | 0.157039E+09 | 12190734.33 | 0.144848E+09 | 0.00 | 0.00 |
| June | 0.556626E+09 | 3652855.89 | 0.138893E+09 | 2831454.13 | 0.136062E+09 | 0.00 | 0.00 |
| July | 0.537685E+09 | 504490.56 | 0.148818E+09 | 1657347.09 | 0.147161E+09 | 0.00 | 0.00 |
| August | 0.488653E+09 | 1445470.43 | 0.156363E+09 | 6555053.33 | 0.149808E+09 | 0.00 | 0.00 |
| September | 0.527130E+09 | 9920087.76 | 0.212171E+09 | 60116108.52 | 0.152055E+09 | 0.00 | 0.00 |
| October | 0.746957E+09 | 0.123424E+09 | 0.362124E+09 | 0.200926E+09 | 0.161198E+09 | 0.00 | 0.00 |
| November | 0.776475E+09 | 0.258241E+09 | 0.442866E+09 | 0.293281E+09 | 0.149585E+09 | 0.00 | 0.00 |
| December | 0.603194E+09 | 0.383190E+09 | 0.405808E+09 | 0.253939E+09 | 0.151870E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.701914E+10 | 0.168471E+10 | 0.325107E+10 | 0.143975E+10 | 0.181132E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.488653E+09 | 504490.56 | 0.138893E+09 | 1657347.09 | 0.136062E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.776475E+09 | 0.397090E+09 | 0.442866E+09 | 0.293281E+09 | 0.172815E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.536030E+09 | 0.397078E+09 | 0.378498E+09 | 0.229085E+09 | 0.149413E+09 | 0.00 | 0.00 |
| February | 0.518180E+09 | 0.281502E+09 | 0.329963E+09 | 0.184565E+09 | 0.145398E+09 | 0.00 | 0.00 |
| March | 0.572892E+09 | 0.174603E+09 | 0.301718E+09 | 0.128904E+09 | 0.172815E+09 | 0.00 | 0.00 |
| April | 0.577377E+09 | 47285062.82 | 0.216806E+09 | 65697605.51 | 0.151109E+09 | 0.00 | 0.00 |
| May | 0.577573E+09 | 3873388.19 | 0.157039E+09 | 12190734.33 | 0.144848E+09 | 0.00 | 0.00 |
| June | 0.556643E+09 | 3650459.74 | 0.138893E+09 | 2831454.13 | 0.136062E+09 | 0.00 | 0.00 |
| July | 0.537683E+09 | 504435.91 | 0.148818E+09 | 1657347.09 | 0.147161E+09 | 0.00 | 0.00 |
| August | 0.488650E+09 | 1445807.66 | 0.156363E+09 | 6555053.33 | 0.149808E+09 | 0.00 | 0.00 |
| September | 0.527130E+09 | 9914082.49 | 0.212171E+09 | 60116108.52 | 0.152055E+09 | 0.00 | 0.00 |
| October | 0.746921E+09 | 0.123414E+09 | 0.362124E+09 | 0.200926E+09 | 0.161198E+09 | 0.00 | 0.00 |
| November | 0.776402E+09 | 0.258231E+09 | 0.442866E+09 | 0.293281E+09 | 0.149585E+09 | 0.00 | 0.00 |
| December | 0.603104E+09 | 0.383188E+09 | 0.405808E+09 | 0.253939E+09 | 0.151870E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.701858E+10 | 0.168469E+10 | 0.325107E+10 | 0.143975E+10 | 0.181132E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.488650E+09 | 504435.91 | 0.138893E+09 | 1657347.09 | 0.136062E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.776402E+09 | 0.397078E+09 | 0.442866E+09 | 0.293281E+09 | 0.172815E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.673535E+09 | 0.575404E+09 | 0.493922E+09 | 0.273962E+09 | 0.219960E+09 | 0.00 | 0.00 |
| February | 0.679378E+09 | 0.421683E+09 | 0.449047E+09 | 0.228381E+09 | 0.220666E+09 | 0.00 | 0.00 |
| March | 0.864747E+09 | 0.275259E+09 | 0.473584E+09 | 0.197970E+09 | 0.275614E+09 | 0.00 | 0.00 |
| April | 0.101236E+10 | 75148999.08 | 0.417829E+09 | 0.159793E+09 | 0.258036E+09 | 0.00 | 0.00 |
| May | 0.108770E+10 | 6690602.20 | 0.353800E+09 | 95520699.22 | 0.258280E+09 | 0.00 | 0.00 |
| June | 0.104983E+10 | 6259507.14 | 0.318515E+09 | 72950561.27 | 0.245564E+09 | 0.00 | 0.00 |
| July | 0.924326E+09 | 819323.36 | 0.286043E+09 | 28271683.34 | 0.257771E+09 | 0.00 | 0.00 |
| August | 0.816440E+09 | 2624729.27 | 0.282190E+09 | 28639824.35 | 0.253550E+09 | 0.00 | 0.00 |
| September | 0.823844E+09 | 16356715.35 | 0.346672E+09 | 99914509.96 | 0.246758E+09 | 0.00 | 0.00 |
| October | 0.102842E+10 | 0.196457E+09 | 0.506391E+09 | 0.258326E+09 | 0.248065E+09 | 0.00 | 0.00 |
| November | 0.975919E+09 | 0.401849E+09 | 0.569149E+09 | 0.347077E+09 | 0.222073E+09 | 0.00 | 0.00 |
| December | 0.739721E+09 | 0.563084E+09 | 0.517616E+09 | 0.296639E+09 | 0.220977E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.106762E+11 | 0.254164E+10 | 0.501476E+10 | 0.208744E+10 | 0.292731E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.673535E+09 | 819323.36 | 0.282190E+09 | 28271683.34 | 0.219960E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.108770E+10 | 0.575404E+09 | 0.569149E+09 | 0.347077E+09 | 0.275614E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.197601E+09 | 0.571126E+09 | 0.199145E+09 | 44877482.19 | 0.154267E+09 | 0.00 | 0.00 |
| February | 0.260398E+09 | 0.419776E+09 | 0.208755E+09 | 43815973.67 | 0.164939E+09 | 0.00 | 0.00 |
| March | 0.498045E+09 | 0.273073E+09 | 0.291528E+09 | 69077107.83 | 0.222450E+09 | 0.00 | 0.00 |
| April | 0.803821E+09 | 72264127.71 | 0.326946E+09 | 94722085.77 | 0.232224E+09 | 0.00 | 0.00 |
| May | 0.105285E+10 | 6777710.85 | 0.341040E+09 | 87794501.12 | 0.253245E+09 | 0.00 | 0.00 |
| June | 0.105914E+10 | 6242167.48 | 0.323325E+09 | 75105750.18 | 0.248220E+09 | 0.00 | 0.00 |
| July | 0.917945E+09 | 814236.81 | 0.284293E+09 | 29143228.13 | 0.255150E+09 | 0.00 | 0.00 |
| August | 0.770509E+09 | 2555940.09 | 0.261075E+09 | 22838960.91 | 0.238236E+09 | 0.00 | 0.00 |
| September | 0.626619E+09 | 15530809.51 | 0.250742E+09 | 39813159.56 | 0.210929E+09 | 0.00 | 0.00 |
| October | 0.522922E+09 | 0.194163E+09 | 0.248314E+09 | 57399869.82 | 0.190914E+09 | 0.00 | 0.00 |
| November | 0.328601E+09 | 0.399531E+09 | 0.211570E+09 | 53795546.57 | 0.157774E+09 | 0.00 | 0.00 |
| December | 0.203011E+09 | 0.549786E+09 | 0.193479E+09 | 42700072.59 | 0.150779E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.724146E+10 | 0.251164E+10 | 0.314021E+10 | 0.661084E+09 | 0.247913E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.197601E+09 | 814236.81 | 0.193479E+09 | 22838960.91 | 0.150779E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.105914E+10 | 0.571126E+09 | 0.341040E+09 | 94722085.77 | 0.255150E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.664189E+09 | 0.563029E+09 | 0.496870E+09 | 0.276825E+09 | 0.220045E+09 | 0.00 | 0.00 |
| February | 0.683111E+09 | 0.411175E+09 | 0.459365E+09 | 0.237840E+09 | 0.221526E+09 | 0.00 | 0.00 |
| March | 0.854636E+09 | 0.262945E+09 | 0.476674E+09 | 0.201032E+09 | 0.275642E+09 | 0.00 | 0.00 |
| April | 0.100930E+10 | 71692092.01 | 0.418850E+09 | 0.160074E+09 | 0.258777E+09 | 0.00 | 0.00 |
| May | 0.110032E+10 | 6341771.29 | 0.361865E+09 | 0.103006E+09 | 0.258859E+09 | 0.00 | 0.00 |
| June | 0.101444E+10 | 6222341.07 | 0.300144E+09 | 56311729.92 | 0.243833E+09 | 0.00 | 0.00 |
| July | 0.932001E+09 | 793872.36 | 0.288699E+09 | 31043005.31 | 0.257656E+09 | 0.00 | 0.00 |
| August | 0.816197E+09 | 2538942.96 | 0.282522E+09 | 28402636.47 | 0.254120E+09 | 0.00 | 0.00 |
| September | 0.815036E+09 | 15808917.09 | 0.342368E+09 | 96200632.37 | 0.246168E+09 | 0.00 | 0.00 |
| October | 0.102766E+10 | 0.191667E+09 | 0.509779E+09 | 0.260636E+09 | 0.249143E+09 | 0.00 | 0.00 |
| November | 0.962927E+09 | 0.392291E+09 | 0.569232E+09 | 0.347409E+09 | 0.221823E+09 | 0.00 | 0.00 |
| December | 0.734943E+09 | 0.555979E+09 | 0.519647E+09 | 0.298997E+09 | 0.220650E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.106148E+11 | 0.248048E+10 | 0.502602E+10 | 0.209778E+10 | 0.292824E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.664189E+09 | 793872.36 | 0.282522E+09 | 28402636.47 | 0.220045E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.110032E+10 | 0.563029E+09 | 0.569232E+09 | 0.347409E+09 | 0.275642E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.169216E+09 | 0.535950E+09 | 0.202093E+09 | 47740397.38 | 0.154352E+09 | 0.00 | 0.00 |
| February | 0.252322E+09 | 0.396996E+09 | 0.219074E+09 | 53274837.78 | 0.165799E+09 | 0.00 | 0.00 |
| March | 0.483536E+09 | 0.257473E+09 | 0.294618E+09 | 72139654.12 | 0.222478E+09 | 0.00 | 0.00 |
| April | 0.801362E+09 | 69567716.23 | 0.327968E+09 | 95002374.23 | 0.232965E+09 | 0.00 | 0.00 |
| May | 0.106559E+10 | 6498700.97 | 0.349104E+09 | 95279844.41 | 0.253825E+09 | 0.00 | 0.00 |
| June | 0.102370E+10 | 6150154.52 | 0.304955E+09 | 58466918.84 | 0.246488E+09 | 0.00 | 0.00 |
| July | 0.925631E+09 | 789573.34 | 0.286950E+09 | 31914550.09 | 0.255035E+09 | 0.00 | 0.00 |
| August | 0.770258E+09 | 2482830.43 | 0.261407E+09 | 22601773.03 | 0.238806E+09 | 0.00 | 0.00 |
| September | 0.617799E+09 | 14965448.31 | 0.246438E+09 | 36099281.96 | 0.210338E+09 | 0.00 | 0.00 |
| October | 0.519190E+09 | 0.186968E+09 | 0.251703E+09 | 59709845.47 | 0.191993E+09 | 0.00 | 0.00 |
| November | 0.307377E+09 | 0.380520E+09 | 0.211653E+09 | 54128288.04 | 0.157525E+09 | 0.00 | 0.00 |
| December | 0.187966E+09 | 0.529743E+09 | 0.195510E+09 | 45058622.97 | 0.150452E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.712396E+10 | 0.238810E+10 | 0.315147E+10 | 0.671416E+09 | 0.248006E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.169216E+09 | 789573.34 | 0.195510E+09 | 22601773.03 | 0.150452E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.106559E+10 | 0.535950E+09 | 0.349104E+09 | 95279844.41 | 0.255035E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 55951390.96 | 0.361944E+09 | 83720776.50 | 0.00 | 83720776.50 | 0.00 | 0.00 |
| February | 89483315.45 | 0.264751E+09 | 89671001.12 | 0.00 | 89671001.12 | 0.00 | 0.00 |
| March | 0.194822E+09 | 0.167550E+09 | 0.119662E+09 | 11416.56 | 0.119651E+09 | 0.00 | 0.00 |
| April | 0.355116E+09 | 42908033.61 | 0.125924E+09 | 626385.41 | 0.125297E+09 | 0.00 | 0.00 |
| May | 0.528145E+09 | 3854398.07 | 0.144278E+09 | 4464536.23 | 0.139814E+09 | 0.00 | 0.00 |
| June | 0.551227E+09 | 3693922.69 | 0.143703E+09 | 4986643.04 | 0.138717E+09 | 0.00 | 0.00 |
| July | 0.517554E+09 | 479036.71 | 0.147069E+09 | 2528891.87 | 0.144540E+09 | 0.00 | 0.00 |
| August | 0.429944E+09 | 1425748.14 | 0.135248E+09 | 754189.90 | 0.134494E+09 | 0.00 | 0.00 |
| September | 0.317016E+09 | 8919625.73 | 0.116241E+09 | 14758.11 | 0.116226E+09 | 0.00 | 0.00 |
| October | 0.227680E+09 | 0.117787E+09 | 0.104047E+09 | 0.00 | 0.104047E+09 | 0.00 | 0.00 |
| November | 0.114432E+09 | 0.248688E+09 | 85286195.69 | 0.00 | 85286195.69 | 0.00 | 0.00 |
| December | 60871897.92 | 0.351965E+09 | 81671108.11 | 0.00 | 81671108.11 | 0.00 | 0.00 |
| Annual Sum or Average | 0.344224E+10 | 0.157397E+10 | 0.137652E+10 | 13386821.13 | 0.136313E+10 | 0.00 | 0.00 |
| Minimum of Months | 55951390.96 | 479036.71 | 81671108.11 | 0.00 | 81671108.11 | 0.00 | 0.00 |
| Maximum of Months | 0.551227E+09 | 0.361944E+09 | 0.147069E+09 | 4986643.04 | 0.144540E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 55637356.37 | 0.361686E+09 | 83720776.50 | 0.00 | 83720776.50 | 0.00 | 0.00 |
| February | 89029859.54 | 0.264714E+09 | 89671001.12 | 0.00 | 89671001.12 | 0.00 | 0.00 |
| March | 0.194476E+09 | 0.167504E+09 | 0.119662E+09 | 11416.56 | 0.119651E+09 | 0.00 | 0.00 |
| April | 0.355037E+09 | 42880077.39 | 0.125924E+09 | 626385.41 | 0.125297E+09 | 0.00 | 0.00 |
| May | 0.528117E+09 | 3848530.27 | 0.144278E+09 | 4464536.23 | 0.139814E+09 | 0.00 | 0.00 |
| June | 0.551247E+09 | 3689878.77 | 0.143703E+09 | 4986643.04 | 0.138717E+09 | 0.00 | 0.00 |
| July | 0.517551E+09 | 479023.80 | 0.147069E+09 | 2528891.87 | 0.144540E+09 | 0.00 | 0.00 |
| August | 0.429939E+09 | 1425774.45 | 0.135248E+09 | 754189.90 | 0.134494E+09 | 0.00 | 0.00 |
| September | 0.317009E+09 | 8908445.47 | 0.116241E+09 | 14758.11 | 0.116226E+09 | 0.00 | 0.00 |
| October | 0.227559E+09 | 0.117737E+09 | 0.104047E+09 | 0.00 | 0.104047E+09 | 0.00 | 0.00 |
| November | 0.114164E+09 | 0.248470E+09 | 85286195.69 | 0.00 | 85286195.69 | 0.00 | 0.00 |
| December | 60536057.45 | 0.351725E+09 | 81671108.11 | 0.00 | 81671108.11 | 0.00 | 0.00 |
| Annual Sum or Average | 0.344030E+10 | 0.157307E+10 | 0.137652E+10 | 13386821.13 | 0.136313E+10 | 0.00 | 0.00 |
| Minimum of Months | 55637356.37 | 479023.80 | 81671108.11 | 0.00 | 81671108.11 | 0.00 | 0.00 |
| Maximum of Months | 0.551247E+09 | 0.361686E+09 | 0.147069E+09 | 4986643.04 | 0.144540E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.549565E+09 | 0.357298E+09 | 0.378498E+09 | 0.229085E+09 | 0.149413E+09 | 0.00 | 0.00 |
| February | 0.520393E+09 | 0.261848E+09 | 0.329963E+09 | 0.184565E+09 | 0.145398E+09 | 0.00 | 0.00 |
| March | 0.567965E+09 | 0.167968E+09 | 0.301718E+09 | 0.128904E+09 | 0.172815E+09 | 0.00 | 0.00 |
| April | 0.566385E+09 | 45251098.22 | 0.216806E+09 | 65697605.51 | 0.151109E+09 | 0.00 | 0.00 |
| May | 0.563575E+09 | 3742500.63 | 0.157039E+09 | 12190734.33 | 0.144848E+09 | 0.00 | 0.00 |
| June | 0.541892E+09 | 3745541.23 | 0.138893E+09 | 2831454.13 | 0.136062E+09 | 0.00 | 0.00 |
| July | 0.524056E+09 | 484528.84 | 0.148818E+09 | 1657347.09 | 0.147161E+09 | 0.00 | 0.00 |
| August | 0.476565E+09 | 1472123.18 | 0.156363E+09 | 6555053.33 | 0.149808E+09 | 0.00 | 0.00 |
| September | 0.516954E+09 | 9507797.24 | 0.212171E+09 | 60116108.52 | 0.152055E+09 | 0.00 | 0.00 |
| October | 0.739957E+09 | 0.118476E+09 | 0.362124E+09 | 0.200926E+09 | 0.161198E+09 | 0.00 | 0.00 |
| November | 0.774552E+09 | 0.246429E+09 | 0.442866E+09 | 0.293281E+09 | 0.149585E+09 | 0.00 | 0.00 |
| December | 0.613188E+09 | 0.351385E+09 | 0.405808E+09 | 0.253939E+09 | 0.151870E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.695505E+10 | 0.156761E+10 | 0.325107E+10 | 0.143975E+10 | 0.181132E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.476565E+09 | 484528.84 | 0.138893E+09 | 1657347.09 | 0.136062E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.774552E+09 | 0.357298E+09 | 0.442866E+09 | 0.293281E+09 | 0.172815E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 0.549166E+09 | 0.357196E+09 | 0.378498E+09 | 0.229085E+09 | 0.149413E+09 | 0.00 | 0.00 |
| February | 0.520026E+09 | 0.261783E+09 | 0.329963E+09 | 0.184565E+09 | 0.145398E+09 | 0.00 | 0.00 |
| March | 0.567702E+09 | 0.167906E+09 | 0.301718E+09 | 0.128904E+09 | 0.172815E+09 | 0.00 | 0.00 |
| April | 0.566316E+09 | 45220539.66 | 0.216806E+09 | 65697605.51 | 0.151109E+09 | 0.00 | 0.00 |
| May | 0.563547E+09 | 3736586.53 | 0.157039E+09 | 12190734.33 | 0.144848E+09 | 0.00 | 0.00 |
| June | 0.541914E+09 | 3741157.23 | 0.138893E+09 | 2831454.13 | 0.136062E+09 | 0.00 | 0.00 |
| July | 0.524054E+09 | 484514.74 | 0.148818E+09 | 1657347.09 | 0.147161E+09 | 0.00 | 0.00 |
| August | 0.476561E+09 | 1472174.84 | 0.156363E+09 | 6555053.33 | 0.149808E+09 | 0.00 | 0.00 |
| September | 0.516949E+09 | 9496451.30 | 0.212171E+09 | 60116108.52 | 0.152055E+09 | 0.00 | 0.00 |
| October | 0.739870E+09 | 0.118428E+09 | 0.362124E+09 | 0.200926E+09 | 0.161198E+09 | 0.00 | 0.00 |
| November | 0.774360E+09 | 0.246316E+09 | 0.442866E+09 | 0.293281E+09 | 0.149585E+09 | 0.00 | 0.00 |
| December | 0.612864E+09 | 0.351282E+09 | 0.405808E+09 | 0.253939E+09 | 0.151870E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.695333E+10 | 0.156706E+10 | 0.325107E+10 | 0.143975E+10 | 0.181132E+10 | 0.00 | 0.00 |
| Minimum of Months | 0.476561E+09 | 484514.74 | 0.138893E+09 | 1657347.09 | 0.136062E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.774360E+09 | 0.357196E+09 | 0.442866E+09 | 0.293281E+09 | 0.172815E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 30958029.00 | 57867666.73 | 28403845.47 | 11455502.67 | 16948342.79 | 0.00 | 0.00 |
| February | 41074035.71 | 43074074.64 | 31050706.47 | 12783514.18 | 18267192.29 | 0.00 | 0.00 |
| March | 69800446.14 | 28943403.90 | 41981367.94 | 17307464.19 | 24673903.75 | 0.00 | 0.00 |
| April | 0.103849E+09 | 9623934.90 | 48481250.38 | 22645902.66 | 25835347.72 | 0.00 | 0.00 |
| May | 0.122821E+09 | 1584763.46 | 49148907.40 | 21791502.85 | 27357404.55 | 0.00 | 0.00 |
| June | 0.106632E+09 | 1376539.74 | 38692928.82 | 12832809.86 | 25860118.96 | 0.00 | 0.00 |
| July | 90093110.87 | 284030.17 | 33564946.11 | 7051208.30 | 26513737.81 | 0.00 | 0.00 |
| August | 74756972.34 | 1179894.14 | 30272480.42 | 5242416.50 | 25030063.92 | 0.00 | 0.00 |
| September | 67379466.55 | 4248656.69 | 31241313.52 | 8658628.38 | 22582685.14 | 0.00 | 0.00 |
| October | 68368249.80 | 22296773.09 | 35430569.31 | 14327620.46 | 21102948.85 | 0.00 | 0.00 |
| November | 46481121.40 | 41164669.74 | 30322204.43 | 12988303.04 | 17333901.39 | 0.00 | 0.00 |
| December | 32177343.45 | 57595399.96 | 27316165.87 | 10811999.99 | 16504165.89 | 0.00 | 0.00 |
| Annual Sum or Average | 0.854390E+09 | 0.269240E+09 | 0.425907E+09 | 0.157897E+09 | 0.268010E+09 | 0.00 | 0.00 |
| Minimum of Months | 30958029.00 | 284030.17 | 27316165.87 | 5242416.50 | 16504165.89 | 0.00 | 0.00 |
| Maximum of Months | 0.122821E+09 | 57867666.73 | 49148907.40 | 22645902.66 | 27357404.55 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 84590954.29 | 0.185328E+09 | 84593720.47 | 34117337.82 | 50476382.65 | 0.00 | 0.00 |
| February | 0.118273E+09 | 0.135096E+09 | 92476731.25 | 38072486.56 | 54404244.69 | 0.00 | 0.00 |
| March | 0.203404E+09 | 92850340.36 | 0.125031E+09 | 51545935.56 | 73485025.79 | 0.00 | 0.00 |
| April | 0.296143E+09 | 37205429.48 | 0.144389E+09 | 67445133.87 | 76944094.97 | 0.00 | 0.00 |
| May | 0.341530E+09 | 10728311.30 | 0.146378E+09 | 64900518.60 | 81477159.01 | 0.00 | 0.00 |
| June | 0.290990E+09 | 8023596.19 | 0.115237E+09 | 38219301.39 | 77017869.89 | 0.00 | 0.00 |
| July | 0.241580E+09 | 3718006.90 | 99964762.60 | 21000253.11 | 78964509.48 | 0.00 | 0.00 |
| August | 0.201683E+09 | 9334706.20 | 90158980.40 | 15613220.99 | 74545759.41 | 0.00 | 0.00 |
| September | 0.185171E+09 | 24712622.22 | 93044406.48 | 25787550.12 | 67256856.36 | 0.00 | 0.00 |
| October | 0.190826E+09 | 81461497.12 | 0.105521E+09 | 42671219.36 | 62849833.43 | 0.00 | 0.00 |
| November | 0.128903E+09 | 0.136878E+09 | 90307070.88 | 38682398.76 | 51624672.12 | 0.00 | 0.00 |
| December | 84605517.39 | 0.190349E+09 | 81354339.96 | 32200826.67 | 49153513.29 | 0.00 | 0.00 |
| Annual Sum or Average | 0.236770E+10 | 0.915686E+09 | 0.126846E+10 | 0.470256E+09 | 0.798200E+09 | 0.00 | 0.00 |
| Minimum of Months | 84590954.29 | 3718006.90 | 81354339.96 | 15613220.99 | 49153513.29 | 0.00 | 0.00 |
| Maximum of Months | 0.341530E+09 | 0.190349E+09 | 0.146378E+09 | 67445133.87 | 81477159.01 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
| January | 25761396.68 | 66388296.34 | 28403845.47 | 11455502.67 | 16948342.79 | 0.00 | 0.00 |
| February | 37894330.20 | 47803927.34 | 31050706.47 | 12783514.18 | 18267192.29 | 0.00 | 0.00 |
| March | 68748036.30 | 30561686.48 | 41981367.94 | 17307464.19 | 24673903.75 | 0.00 | 0.00 |
| April | 0.105226E+09 | 10026701.16 | 48481250.38 | 22645902.66 | 25835347.72 | 0.00 | 0.00 |
| May | 0.125789E+09 | 1601718.47 | 49148907.40 | 21791502.85 | 27357404.55 | 0.00 | 0.00 |
| June | 0.109920E+09 | 1314571.93 | 38692928.82 | 12832809.86 | 25860118.96 | 0.00 | 0.00 |
| July | 93339686.61 | 275894.79 | 33564946.11 | 7051208.30 | 26513737.81 | 0.00 | 0.00 |
| August | 77329753.61 | 1104940.04 | 30272480.42 | 5242416.50 | 25030063.92 | 0.00 | 0.00 |
| September | 68847899.05 | 4204775.19 | 31241313.52 | 8658628.38 | 22582685.14 | 0.00 | 0.00 |
| October | 68161394.53 | 23346608.30 | 35430569.31 | 14327620.46 | 21102948.85 | 0.00 | 0.00 |
| November | 44175209.87 | 44448782.49 | 30322204.43 | 12988303.04 | 17333901.39 | 0.00 | 0.00 |
| December | 27195039.18 | 66009154.12 | 27316165.87 | 10811999.99 | 16504165.89 | 0.00 | 0.00 |
| Annual Sum or Average | 0.852388E+09 | 0.297087E+09 | 0.425907E+09 | 0.157897E+09 | 0.268010E+09 | 0.00 | 0.00 |
| Minimum of Months | 25761396.68 | 275894.79 | 27316165.87 | 5242416.50 | 16504165.89 | 0.00 | 0.00 |
| Maximum of Months | 0.125789E+09 | 66388296.34 | 49148907.40 | 22645902.66 | 27357404.55 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
| January | 13.39 | 10.38 | 7.87 | 1.20 | 0.38 | 63.33 | 149.51 | 0.00 |
| February | 16.97 | 12.78 | 9.69 | 1.81 | 4.63 | 75.94 | 163.32 | 0.01 |
| March | 22.37 | 15.60 | 11.23 | 1.86 | 10.07 | 92.70 | 193.23 | 0.00 |
| April | 29.13 | 18.33 | 11.93 | 1.64 | 16.17 | 89.20 | 259.84 | 0.01 |
| May | 32.98 | 21.97 | 16.72 | 2.17 | 21.14 | 97.31 | 248.85 | 0.02 |
| June | 33.59 | 24.39 | 20.62 | 1.55 | 23.45 | 107.22 | 203.36 | 0.06 |
| July | 31.67 | 26.29 | 24.51 | 2.27 | 24.88 | 132.35 | 83.14 | 0.02 |
| August | 30.03 | 26.31 | 25.11 | 1.75 | 23.81 | 127.44 | 60.46 | 0.00 |
| September | 28.75 | 24.70 | 23.21 | 1.33 | 20.22 | 105.62 | 105.60 | 0.08 |
| October | 25.09 | 18.74 | 15.36 | 0.77 | 12.83 | 75.09 | 190.08 | 0.00 |
| November | 19.63 | 14.46 | 10.99 | 0.66 | 5.78 | 58.54 | 201.10 | 0.00 |
| December | 14.52 | 10.88 | 7.89 | 0.97 | 0.94 | 60.91 | 153.60 | 0.01 |
| Annual Sum or Average | 24.88 | 18.77 | 15.46 | 1.50 | 13.74 | 90.59 | 167.44 | 0.02 |
| Minimum of Months | 13.39 | 10.38 | 7.87 | 0.66 | 0.38 | 58.54 | 60.46 | 0.00 |
| Maximum of Months | 33.59 | 26.31 | 25.11 | 2.27 | 24.88 | 132.35 | 259.84 | 0.08 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 23.60 | 12-JAN-14:00 | 14.20 | 7.40 | 3.80 | 8.15 | 163.00 | 476.00 |
| February | 27.10 | 22-FEB-14:00 | 16.20 | 9.10 | 1.50 | 15.39 | 225.00 | 451.00 |
| March | 35.60 | 28-MAR-14:00 | 18.50 | 7.70 | 0.00 | 19.52 | 182.00 | 699.00 |
| April | 40.30 | 15-APR-14:00 | 20.67 | 10.00 | 6.70 | 28.43 | 201.00 | 649.50 |
| May | 44.50 | 03-MAY-14:00 | 20.64 | 5.30 | 2.80 | 28.91 | 150.00 | 809.00 |
| June | 44.60 | 07-JUN-15:00 | 21.53 | 9.10 | 3.10 | 28.43 | 167.00 | 640.50 |
| July | 40.40 | 02-JUL-15:00 | 26.36 | 21.60 | 2.10 | 29.87 | 200.00 | 545.50 |
| August | 37.30 | 07-AUG-14:00 | 26.58 | 22.90 | 3.00 | 29.87 | 311.00 | 370.00 |
| September | 37.50 | 17-SEP-19:00 | 27.68 | 24.60 | 0.20 | 28.59 | 0.00 | 0.00 |
| October | 36.40 | 02-OCT-14:20 | 21.05 | 13.00 | 1.80 | 21.61 | 187.33 | 678.83 |
| November | 30.30 | 04-NOV-13:00 | 17.17 | 8.90 | 1.10 | 14.84 | 155.00 | 710.00 |
| December | 24.60 | 28-DEC-13:00 | 15.30 | 8.90 | 2.80 | 10.88 | 181.50 | 535.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 23.60 | 14.20 | 5.30 | 0.00 | 8.15 | 0.00 | 0.00 | |
| Maximum of Months | 44.60 | 27.68 | 24.60 | 6.70 | 29.87 | 311.00 | 809.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 4.80 | 05-JAN-06:00 | 4.73 | 4.60 | 0.00 | -10.2 | 0.00 | 0.00 |
| February | 6.90 | 02-FEB-05:00 | 6.67 | 6.50 | 0.00 | -7.8 | 0.00 | 0.00 |
| March | 13.30 | 01-MAR-03:00 | 10.56 | 8.30 | 0.80 | -1.4 | 0.00 | 0.00 |
| April | 17.40 | 11-APR-04:00 | 13.58 | 10.90 | 0.00 | 3.06 | 0.00 | 0.00 |
| May | 22.70 | 13-MAY-04:00 | 20.32 | 19.30 | 2.10 | 20.40 | 0.00 | 0.00 |
| June | 23.30 | 18-JUN-04:00 | 21.80 | 21.20 | 2.70 | 17.75 | 0.00 | 0.00 |
| July | 23.20 | 19-JUL-02:00 | 23.20 | 23.20 | 2.30 | 15.39 | 0.00 | 0.00 |
| August | 23.40 | 15-AUG-23:00 | 22.91 | 22.80 | 2.40 | 21.78 | 0.00 | 0.00 |
| September | 23.00 | 27-SEP-04:00 | 20.74 | 19.70 | 0.00 | 10.30 | 0.00 | 0.00 |
| October | 15.50 | 31-OCT-04:00 | 14.07 | 13.20 | 0.00 | 1.80 | 0.00 | 0.00 |
| November | 9.50 | 27-NOV-05:00 | 8.75 | 8.10 | 0.00 | -5.0 | 0.00 | 0.00 |
| December | 5.00 | 21-DEC-04:00 | 4.08 | 3.00 | 0.00 | -10.5 | 0.00 | 0.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 4.80 | 4.08 | 3.00 | 0.00 | -10.5 | 0.00 | 0.00 | |
| Maximum of Months | 23.40 | 23.20 | 23.20 | 2.70 | 21.78 | 0.00 | 0.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 15.62 | 17-JAN-14:00 | 18.20 | 14.10 | 1.00 | 11.07 | 198.00 | 56.50 |
| February | 18.14 | 25-FEB-16:00 | 21.20 | 16.60 | 5.90 | 10.88 | 107.50 | 156.50 |
| March | 21.38 | 10-MAR-18:49 | 29.25 | 17.73 | 2.10 | 21.44 | 0.00 | 0.00 |
| April | 23.42 | 18-APR-13:00 | 37.10 | 17.80 | 5.70 | 23.49 | 233.50 | 671.50 |
| May | 27.40 | 22-MAY-22:00 | 29.40 | 26.80 | 0.00 | 20.40 | 0.00 | 0.00 |
| June | 28.92 | 28-JUN-12:00 | 34.40 | 27.50 | 1.00 | 25.49 | 332.50 | 501.50 |
| July | 29.18 | 01-JUL-16:00 | 37.20 | 26.80 | 2.30 | 25.66 | 196.00 | 196.00 |
| August | 29.17 | 27-AUG-15:00 | 35.10 | 27.40 | 1.30 | 29.55 | 256.00 | 129.00 |
| September | 28.10 | 14-SEP-16:00 | 33.70 | 26.40 | 1.40 | 26.48 | 122.50 | 108.50 |
| October | 23.06 | 06-OCT-10:00 | 28.60 | 20.80 | 1.30 | 20.22 | 327.00 | 348.50 |
| November | 18.93 | 08-NOV-17:10 | 27.55 | 14.47 | 0.17 | 16.67 | 28.00 | 65.33 |
| December | 15.64 | 29-DEC-19:00 | 16.80 | 14.90 | 4.80 | 13.54 | 0.00 | 0.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 15.62 | 16.80 | 14.10 | 0.00 | 10.88 | 0.00 | 0.00 | |
| Maximum of Months | 29.18 | 37.20 | 27.50 | 5.90 | 29.55 | 332.50 | 671.50 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
| January | 14.10 | 17-JAN-13:00 | 17.80 | 15.48 | 0.90 | 9.72 | 260.50 | 81.50 |
| February | 16.60 | 25-FEB-16:00 | 21.20 | 18.14 | 5.90 | 10.88 | 107.50 | 156.50 |
| March | 18.30 | 10-MAR-19:00 | 27.70 | 21.26 | 2.10 | 21.44 | 0.00 | 0.00 |
| April | 19.30 | 26-APR-23:10 | 28.53 | 22.04 | 0.00 | 15.61 | 0.00 | 0.00 |
| May | 26.80 | 22-MAY-22:00 | 29.40 | 27.40 | 0.00 | 20.40 | 0.00 | 0.00 |
| June | 27.50 | 28-JUN-12:00 | 34.40 | 28.92 | 1.00 | 25.49 | 332.50 | 501.50 |
| July | 27.30 | 18-JUL-06:19 | 29.10 | 27.70 | 1.17 | 26.48 | 20.00 | 0.00 |
| August | 28.80 | 12-AUG-07:00 | 29.10 | 28.83 | 2.90 | 26.81 | 113.00 | 6.50 |
| September | 26.50 | 12-SEP-14:00 | 30.50 | 27.38 | 0.90 | 25.99 | 260.00 | 20.00 |
| October | 21.10 | 06-OCT-08:00 | 25.50 | 22.41 | 0.30 | 17.21 | 239.00 | 159.00 |
| November | 16.30 | 08-NOV-21:19 | 20.10 | 17.59 | 0.00 | 10.95 | 0.00 | 0.00 |
| December | 14.90 | 29-DEC-20:10 | 16.72 | 15.59 | 4.73 | 13.13 | 0.00 | 0.00 |
| Annual Sum or Average | ||||||||
| Minimum of Months | 14.10 | 16.72 | 15.48 | 0.00 | 9.72 | 0.00 | 0.00 | |
| Maximum of Months | 28.80 | 34.40 | 28.92 | 5.90 | 26.81 | 332.50 | 501.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
| January | 18.00 | 13.00 | 16.00 | 20.92 | 27.26 | 0.00 |
| February | 18.00 | 13.00 | 16.00 | 21.74 | 33.91 | 0.00 |
| March | 18.00 | 13.00 | 16.00 | 24.21 | 44.04 | 0.00 |
| April | 18.00 | 13.00 | 16.00 | 27.79 | 55.91 | 0.00 |
| May | 18.00 | 13.00 | 16.00 | 31.48 | 58.43 | 0.00 |
| June | 18.00 | 13.00 | 16.00 | 34.27 | 54.82 | 0.00 |
| July | 18.00 | 13.00 | 16.00 | 35.42 | 39.75 | 0.00 |
| August | 18.00 | 13.00 | 16.00 | 34.60 | 34.68 | 0.00 |
| September | 18.00 | 13.00 | 16.00 | 32.04 | 35.55 | 0.00 |
| October | 18.00 | 13.00 | 16.00 | 28.44 | 39.44 | 0.00 |
| November | 18.00 | 13.00 | 16.00 | 24.77 | 33.85 | 0.00 |
| December | 18.00 | 13.00 | 16.00 | 22.02 | 26.79 | 0.00 |
| Annual Sum or Average | 18.00 | 13.00 | 16.00 | 28.18 | 40.37 | 0.00 |
| Minimum of Months | 18.00 | 13.00 | 16.00 | 20.92 | 26.79 | 0.00 |
| Maximum of Months | 18.00 | 13.00 | 16.00 | 35.42 | 58.43 | 0.00 |
Report: WaterHeaterReportMonthly
For: SWHSYS1 WATER HEATER
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
| January | 0.269732E+11 | -0.260070E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -966252098.3 | 59.95 | 0.00 | 0.00 |
| February | 0.238367E+11 | -0.229947E+11 | 0.00 | 0.00 | 672.00 | 0.00 | -842081521.1 | 59.95 | 0.00 | 0.00 |
| March | 0.247066E+11 | -0.238119E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -894699914.5 | 59.95 | 0.00 | 0.00 |
| April | 0.215611E+11 | -0.207341E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -827003770.1 | 59.95 | 0.00 | 0.00 |
| May | 0.198012E+11 | -0.189697E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -831424851.0 | 59.95 | 0.00 | 0.00 |
| June | 0.173536E+11 | -0.165521E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -801548814.9 | 59.95 | 0.00 | 0.00 |
| July | 0.171741E+11 | -0.163379E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -836172702.1 | 59.95 | 0.00 | 0.00 |
| August | 0.177331E+11 | -0.168891E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -843979432.0 | 59.95 | 0.00 | 0.00 |
| September | 0.188159E+11 | -0.179931E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -822848407.5 | 59.95 | 0.00 | 0.00 |
| October | 0.218582E+11 | -0.209938E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -864395245.7 | 59.95 | 0.00 | 0.00 |
| November | 0.235546E+11 | -0.226855E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -869061548.7 | 59.95 | 0.00 | 0.00 |
| December | 0.262161E+11 | -0.252755E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -940553083.7 | 59.95 | 0.00 | 0.00 |
| Annual Sum or Average | 0.259584E+12 | -0.249244E+12 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.103400E+11 | 59.95 | 0.00 | 0.00 |
| Minimum of Months | 0.171741E+11 | -0.260070E+11 | 0.00 | 0.00 | 672.00 | 0.00 | -966252098.3 | 59.95 | 0.00 | 0.00 |
| Maximum of Months | 0.269732E+11 | -0.163379E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -801548814.9 | 59.95 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
| January | 319.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 303.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 364.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 379.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 406.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 386.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 379.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 372.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 344.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 347.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 317.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 315.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 4237.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 303.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 406.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 2041751.17 | 69.59 | 03-JAN-08:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 2041751.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 2041751.17 | 69.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 124166.39 | 1253.85 | 03-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 124166.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 124166.39 | 1253.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 1797757.19 | 71.11 | 03-JAN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 1797757.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 1797757.19 | 71.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 324487.07 | 61.61 | 02-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 324487.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 324487.07 | 61.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 827615.90 | 86.06 | 02-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 827615.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 827615.90 | 86.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.150191E+09 | 696.13 | 02-JAN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 20525536.36 | 518.68 | 11-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 51765566.23 | 630.39 | 23-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.222482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.150191E+09 | 696.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.382847E+09 | 875.21 | 02-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 54211287.52 | 517.17 | 11-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.179921E+09 | 859.94 | 23-DEC-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.616979E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.382847E+09 | 875.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.140802E+09 | 707.72 | 02-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 18718344.43 | 523.52 | 11-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 49294285.47 | 619.90 | 23-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.208815E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.140802E+09 | 707.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.357233E+09 | 892.49 | 02-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 48604686.25 | 522.03 | 11-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.171862E+09 | 849.53 | 23-DEC-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.577700E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.357233E+09 | 892.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.167016E+09 | 548.03 | 02-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 10025962.79 | 208.79 | 02-FEB-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 55417981.45 | 506.60 | 23-DEC-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.232460E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.167016E+09 | 548.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.167724E+09 | 550.01 | 02-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 10027375.92 | 206.42 | 02-FEB-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 55527553.35 | 503.98 | 23-DEC-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.233279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.167724E+09 | 550.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 19536920.16 | 346.43 | 02-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 2409218.58 | 192.78 | 11-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 4789334.92 | 254.77 | 23-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 26735473.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 19536920.16 | 346.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2 HEATING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 19630634.04 | 347.47 | 02-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 2431690.81 | 193.85 | 11-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 4754744.00 | 252.18 | 23-DEC-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 26817068.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 19630634.04 | 347.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2_SUPPHEATCOIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GSW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.426025E+09 | 0.410153E+09 | 6716.81 | 18-JAN-19:42 | 5855.17 | 0.00 |
| February | 0.00 | 0.00 | 0.856535E+09 | 0.818477E+09 | 6941.09 | 25-FEB-19:22 | 5443.58 | 0.00 |
| March | 0.00 | 0.00 | 0.213660E+10 | 0.200776E+10 | 6943.96 | 18-MAR-11:12 | 5261.06 | 0.00 |
| April | 0.00 | 0.00 | 0.367283E+10 | 0.346200E+10 | 6969.64 | 24-APR-07:42 | 5084.46 | 0.00 |
| May | 0.00 | 0.00 | 0.505306E+10 | 0.448854E+10 | 7056.50 | 13-MAY-07:52 | 4961.84 | 0.00 |
| June | 0.00 | 0.00 | 0.558893E+10 | 0.468138E+10 | 7063.61 | 18-JUN-06:52 | 4948.69 | 0.00 |
| July | 0.00 | 0.00 | 0.627964E+10 | 0.485185E+10 | 3569.12 | 02-JUL-17:10 | 3120.04 | 0.00 |
| August | 0.00 | 0.00 | 0.620726E+10 | 0.472611E+10 | 3444.77 | 13-AUG-16:15 | 2728.74 | 0.00 |
| September | 0.00 | 0.00 | 0.561826E+10 | 0.445180E+10 | 6906.97 | 27-SEP-07:12 | 5467.09 | 0.00 |
| October | 0.00 | 0.00 | 0.433712E+10 | 0.392846E+10 | 7154.46 | 13-OCT-09:12 | 4678.72 | 0.00 |
| November | 0.00 | 0.00 | 0.254301E+10 | 0.241114E+10 | 6856.64 | 09-NOV-09:32 | 5748.16 | 0.00 |
| December | 0.00 | 0.00 | 0.100970E+10 | 0.975464E+09 | 6779.48 | 10-DEC-19:22 | 5912.03 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.437290E+11 | 0.372131E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.426025E+09 | 0.410153E+09 | 3444.77 | 2728.74 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.627964E+10 | 0.485185E+10 | 7154.46 | 5912.03 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 17459077.06 | 15261277.52 | 5254.37 | 14-JAN-22:52 | 4713.21 | 0.00 |
| February | 0.00 | 0.00 | 0.254345E+09 | 0.239363E+09 | 6873.98 | 25-FEB-17:02 | 5407.10 | 0.00 |
| March | 0.00 | 0.00 | 0.143289E+10 | 0.132875E+10 | 6857.87 | 18-MAR-11:52 | 5254.58 | 0.00 |
| April | 0.00 | 0.00 | 0.320658E+10 | 0.300427E+10 | 6918.05 | 24-APR-07:42 | 4986.23 | 0.00 |
| May | 0.00 | 0.00 | 0.496689E+10 | 0.440085E+10 | 6981.65 | 13-MAY-07:52 | 4971.82 | 0.00 |
| June | 0.00 | 0.00 | 0.562333E+10 | 0.471080E+10 | 6998.86 | 18-JUN-06:52 | 4927.31 | 0.00 |
| July | 0.00 | 0.00 | 0.628929E+10 | 0.486083E+10 | 3554.01 | 02-JUL-17:20 | 3121.08 | 0.00 |
| August | 0.00 | 0.00 | 0.613007E+10 | 0.464882E+10 | 3349.39 | 07-AUG-17:10 | 2824.07 | 0.00 |
| September | 0.00 | 0.00 | 0.521970E+10 | 0.406921E+10 | 6863.18 | 27-SEP-07:12 | 5374.30 | 0.00 |
| October | 0.00 | 0.00 | 0.335170E+10 | 0.297418E+10 | 7120.53 | 13-OCT-09:32 | 4526.53 | 0.00 |
| November | 0.00 | 0.00 | 0.140184E+10 | 0.130234E+10 | 6810.03 | 08-NOV-22:52 | 5649.81 | 0.00 |
| December | 0.00 | 0.00 | 0.181894E+09 | 0.172230E+09 | 6683.49 | 10-DEC-19:22 | 5653.51 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.380760E+11 | 0.317269E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 17459077.06 | 15261277.52 | 3349.39 | 2824.07 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.628929E+10 | 0.486083E+10 | 7120.53 | 5653.51 | 0.00 |
Report: CoilReportMonthly
For: SPLIT OFFICE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.708189E+09 | 0.690206E+09 | 3706.08 | 26-JAN-07:01 | 3294.07 | 0.00 |
| February | 0.00 | 0.00 | 0.108234E+10 | 0.103387E+10 | 7489.58 | 23-FEB-07:01 | 6723.04 | 0.00 |
| March | 0.00 | 0.00 | 0.207972E+10 | 0.196331E+10 | 7876.89 | 29-MAR-06:01 | 6358.71 | 0.00 |
| April | 0.00 | 0.00 | 0.299701E+10 | 0.283353E+10 | 8160.69 | 26-APR-06:01 | 5840.34 | 0.00 |
| May | 0.00 | 0.00 | 0.456201E+10 | 0.404568E+10 | 8486.37 | 24-MAY-06:01 | 4845.12 | 0.00 |
| June | 0.00 | 0.00 | 0.507555E+10 | 0.416539E+10 | 8473.92 | 28-JUN-06:04 | 3547.34 | 0.00 |
| July | 0.00 | 0.00 | 0.544952E+10 | 0.393740E+10 | 8486.96 | 26-JUL-06:01 | 4316.46 | 0.00 |
| August | 0.00 | 0.00 | 0.558525E+10 | 0.396773E+10 | 8497.30 | 16-AUG-06:02 | 4250.07 | 0.00 |
| September | 0.00 | 0.00 | 0.453891E+10 | 0.342872E+10 | 8497.37 | 07-SEP-06:02 | 4176.26 | 0.00 |
| October | 0.00 | 0.00 | 0.358125E+10 | 0.323337E+10 | 8323.55 | 04-OCT-06:01 | 5673.15 | 0.00 |
| November | 0.00 | 0.00 | 0.221098E+10 | 0.212032E+10 | 7801.54 | 09-NOV-07:01 | 6298.13 | 0.00 |
| December | 0.00 | 0.00 | 0.112040E+10 | 0.109952E+10 | 7348.32 | 29-DEC-07:01 | 7238.72 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.389911E+11 | 0.325191E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.708189E+09 | 0.690206E+09 | 3706.08 | 3294.07 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.558525E+10 | 0.416539E+10 | 8497.37 | 7238.72 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GNE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 16231167.80 | 14158910.79 | 4922.07 | 14-JAN-22:52 | 4408.77 | 0.00 |
| February | 0.00 | 0.00 | 0.258471E+09 | 0.242562E+09 | 6636.85 | 25-FEB-17:02 | 5078.85 | 0.00 |
| March | 0.00 | 0.00 | 0.143054E+10 | 0.132395E+10 | 6635.22 | 18-MAR-11:52 | 5110.06 | 0.00 |
| April | 0.00 | 0.00 | 0.322717E+10 | 0.302095E+10 | 6697.45 | 24-APR-07:42 | 4877.81 | 0.00 |
| May | 0.00 | 0.00 | 0.499607E+10 | 0.442781E+10 | 6755.16 | 13-MAY-07:52 | 4799.58 | 0.00 |
| June | 0.00 | 0.00 | 0.556855E+10 | 0.465714E+10 | 6770.25 | 18-JUN-06:52 | 4749.45 | 0.00 |
| July | 0.00 | 0.00 | 0.629337E+10 | 0.486424E+10 | 3255.61 | 01-JUL-17:10 | 2545.26 | 0.00 |
| August | 0.00 | 0.00 | 0.613434E+10 | 0.465253E+10 | 3135.67 | 07-AUG-17:20 | 2618.08 | 0.00 |
| September | 0.00 | 0.00 | 0.520392E+10 | 0.405337E+10 | 6653.78 | 27-SEP-07:12 | 5131.77 | 0.00 |
| October | 0.00 | 0.00 | 0.336746E+10 | 0.298661E+10 | 6874.90 | 13-OCT-09:32 | 4390.63 | 0.00 |
| November | 0.00 | 0.00 | 0.139297E+10 | 0.129200E+10 | 6585.48 | 08-NOV-22:52 | 5442.75 | 0.00 |
| December | 0.00 | 0.00 | 0.176924E+09 | 0.167363E+09 | 6405.77 | 16-DEC-20:42 | 5801.92 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.380660E+11 | 0.317027E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 16231167.80 | 14158910.79 | 3135.67 | 2545.26 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.629337E+10 | 0.486424E+10 | 6874.90 | 5801.92 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 78333552.14 | 68801956.61 | 5637.91 | 14-JAN-22:52 | 5094.57 | 0.00 |
| February | 0.00 | 0.00 | 0.336879E+09 | 0.310849E+09 | 5857.50 | 25-FEB-17:02 | 4484.46 | 0.00 |
| March | 0.00 | 0.00 | 0.135437E+10 | 0.124422E+10 | 5856.93 | 18-MAR-11:52 | 4511.16 | 0.00 |
| April | 0.00 | 0.00 | 0.268524E+10 | 0.249057E+10 | 5904.98 | 24-APR-07:42 | 4283.10 | 0.00 |
| May | 0.00 | 0.00 | 0.410052E+10 | 0.356885E+10 | 5956.64 | 13-MAY-07:52 | 4240.86 | 0.00 |
| June | 0.00 | 0.00 | 0.465454E+10 | 0.379342E+10 | 5978.35 | 18-JUN-06:52 | 4188.05 | 0.00 |
| July | 0.00 | 0.00 | 0.531082E+10 | 0.397482E+10 | 2700.13 | 01-JUL-17:13 | 2027.12 | 0.00 |
| August | 0.00 | 0.00 | 0.520433E+10 | 0.381098E+10 | 2580.82 | 27-AUG-16:30 | 1899.00 | 0.00 |
| September | 0.00 | 0.00 | 0.441986E+10 | 0.333360E+10 | 5891.15 | 27-SEP-07:12 | 4472.63 | 0.00 |
| October | 0.00 | 0.00 | 0.284928E+10 | 0.248884E+10 | 6081.18 | 13-OCT-09:32 | 3851.76 | 0.00 |
| November | 0.00 | 0.00 | 0.132453E+10 | 0.122181E+10 | 5816.78 | 08-NOV-22:52 | 4785.37 | 0.00 |
| December | 0.00 | 0.00 | 0.354337E+09 | 0.333600E+09 | 5800.13 | 29-DEC-22:52 | 4468.06 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.326730E+11 | 0.266404E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 78333552.14 | 68801956.61 | 2580.82 | 1899.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.531082E+10 | 0.397482E+10 | 6081.18 | 5094.57 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GN2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 78645491.22 | 69170819.79 | 5634.04 | 14-JAN-22:52 | 5097.89 | 0.00 |
| February | 0.00 | 0.00 | 0.340188E+09 | 0.314175E+09 | 5853.78 | 25-FEB-17:02 | 4488.48 | 0.00 |
| March | 0.00 | 0.00 | 0.135778E+10 | 0.124820E+10 | 5853.18 | 18-MAR-11:52 | 4515.02 | 0.00 |
| April | 0.00 | 0.00 | 0.268615E+10 | 0.249242E+10 | 5901.42 | 24-APR-07:42 | 4285.71 | 0.00 |
| May | 0.00 | 0.00 | 0.410022E+10 | 0.356994E+10 | 5953.00 | 13-MAY-07:52 | 4241.78 | 0.00 |
| June | 0.00 | 0.00 | 0.465109E+10 | 0.379152E+10 | 5975.01 | 18-JUN-06:52 | 4187.83 | 0.00 |
| July | 0.00 | 0.00 | 0.530939E+10 | 0.397487E+10 | 2696.68 | 01-JUL-17:13 | 2024.84 | 0.00 |
| August | 0.00 | 0.00 | 0.520305E+10 | 0.381111E+10 | 2578.35 | 27-AUG-16:30 | 1897.57 | 0.00 |
| September | 0.00 | 0.00 | 0.441787E+10 | 0.333300E+10 | 5887.89 | 27-SEP-07:12 | 4472.80 | 0.00 |
| October | 0.00 | 0.00 | 0.284991E+10 | 0.249062E+10 | 6077.17 | 13-OCT-09:32 | 3852.71 | 0.00 |
| November | 0.00 | 0.00 | 0.132625E+10 | 0.122422E+10 | 5813.38 | 08-NOV-22:52 | 4786.62 | 0.00 |
| December | 0.00 | 0.00 | 0.354622E+09 | 0.334154E+09 | 5796.22 | 29-DEC-22:52 | 4470.75 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.326751E+11 | 0.266534E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 78645491.22 | 69170819.79 | 2578.35 | 1897.57 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.530939E+10 | 0.397487E+10 | 6077.17 | 5097.89 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.736954E+09 | 0.708143E+09 | 5844.39 | 17-JAN-20:33 | 4840.40 | 0.00 |
| February | 0.00 | 0.00 | 0.108080E+10 | 0.102729E+10 | 5973.24 | 25-FEB-19:22 | 4675.20 | 0.00 |
| March | 0.00 | 0.00 | 0.209654E+10 | 0.196142E+10 | 5982.83 | 18-MAR-11:12 | 4592.66 | 0.00 |
| April | 0.00 | 0.00 | 0.317239E+10 | 0.296813E+10 | 5994.71 | 24-APR-07:42 | 4409.91 | 0.00 |
| May | 0.00 | 0.00 | 0.420103E+10 | 0.367064E+10 | 6066.65 | 13-MAY-07:52 | 4270.44 | 0.00 |
| June | 0.00 | 0.00 | 0.463058E+10 | 0.377504E+10 | 6079.23 | 18-JUN-06:52 | 4243.09 | 0.00 |
| July | 0.00 | 0.00 | 0.531311E+10 | 0.397803E+10 | 2726.45 | 01-JUL-17:02 | 2037.25 | 0.00 |
| August | 0.00 | 0.00 | 0.529550E+10 | 0.390088E+10 | 2755.73 | 27-AUG-16:02 | 2045.23 | 0.00 |
| September | 0.00 | 0.00 | 0.483983E+10 | 0.373268E+10 | 5958.65 | 27-SEP-07:12 | 4641.65 | 0.00 |
| October | 0.00 | 0.00 | 0.386045E+10 | 0.346456E+10 | 6148.18 | 13-OCT-09:12 | 4041.22 | 0.00 |
| November | 0.00 | 0.00 | 0.249973E+10 | 0.236413E+10 | 5895.16 | 09-NOV-09:32 | 4952.15 | 0.00 |
| December | 0.00 | 0.00 | 0.131557E+10 | 0.127253E+10 | 5919.35 | 29-DEC-22:52 | 4722.60 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.390425E+11 | 0.328235E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.736954E+09 | 0.708143E+09 | 2726.45 | 2037.25 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.531311E+10 | 0.397803E+10 | 6148.18 | 4952.15 | 0.00 |
Report: CoilReportMonthly
For: SPLIT GS2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.724191E+09 | 0.695594E+09 | 5895.22 | 17-JAN-20:33 | 4887.02 | 0.00 |
| February | 0.00 | 0.00 | 0.111045E+10 | 0.105567E+10 | 6014.16 | 25-FEB-19:22 | 4707.43 | 0.00 |
| March | 0.00 | 0.00 | 0.222058E+10 | 0.208098E+10 | 6038.61 | 18-MAR-11:12 | 4659.45 | 0.00 |
| April | 0.00 | 0.00 | 0.343368E+10 | 0.322238E+10 | 6032.12 | 24-APR-07:42 | 4560.36 | 0.00 |
| May | 0.00 | 0.00 | 0.453378E+10 | 0.399015E+10 | 6106.55 | 13-MAY-07:52 | 4390.39 | 0.00 |
| June | 0.00 | 0.00 | 0.495472E+10 | 0.408171E+10 | 6111.04 | 18-JUN-06:52 | 4352.77 | 0.00 |
| July | 0.00 | 0.00 | 0.567842E+10 | 0.431798E+10 | 2882.78 | 01-JUL-17:02 | 2186.10 | 0.00 |
| August | 0.00 | 0.00 | 0.564221E+10 | 0.422222E+10 | 2933.01 | 27-AUG-16:02 | 2214.49 | 0.00 |
| September | 0.00 | 0.00 | 0.517382E+10 | 0.404417E+10 | 5992.74 | 27-SEP-07:12 | 4742.06 | 0.00 |
| October | 0.00 | 0.00 | 0.412262E+10 | 0.371777E+10 | 6179.69 | 13-OCT-09:12 | 4141.62 | 0.00 |
| November | 0.00 | 0.00 | 0.263972E+10 | 0.249993E+10 | 5942.41 | 09-NOV-09:32 | 5003.20 | 0.00 |
| December | 0.00 | 0.00 | 0.133567E+10 | 0.129235E+10 | 5970.96 | 29-DEC-22:52 | 4769.91 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.415699E+11 | 0.352209E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.724191E+09 | 0.695594E+09 | 2882.78 | 2186.10 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.567842E+10 | 0.431798E+10 | 6179.69 | 5003.20 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.116973E+10 | 0.113353E+10 | 14828.23 | 18-JAN-19:42 | 12998.68 | 0.00 |
| February | 0.00 | 0.00 | 0.248701E+10 | 0.238239E+10 | 15233.92 | 25-FEB-19:22 | 12093.95 | 0.00 |
| March | 0.00 | 0.00 | 0.569630E+10 | 0.539461E+10 | 15347.76 | 18-MAR-11:12 | 11866.79 | 0.00 |
| April | 0.00 | 0.00 | 0.875828E+10 | 0.830742E+10 | 15339.41 | 24-APR-07:42 | 11421.14 | 0.00 |
| May | 0.00 | 0.00 | 0.110020E+11 | 0.982311E+10 | 15572.07 | 13-MAY-07:52 | 10838.10 | 0.00 |
| June | 0.00 | 0.00 | 0.113561E+11 | 0.950707E+10 | 15634.34 | 18-JUN-06:52 | 10526.35 | 0.00 |
| July | 0.00 | 0.00 | 0.119320E+11 | 0.904857E+10 | 7290.59 | 01-JUL-16:30 | 5712.81 | 0.00 |
| August | 0.00 | 0.00 | 0.112559E+11 | 0.832228E+10 | 6849.37 | 13-AUG-16:15 | 5369.29 | 0.00 |
| September | 0.00 | 0.00 | 0.100367E+11 | 0.775882E+10 | 15363.63 | 27-SEP-07:12 | 11445.11 | 0.00 |
| October | 0.00 | 0.00 | 0.788937E+10 | 0.710889E+10 | 15937.79 | 13-OCT-09:12 | 9607.88 | 0.00 |
| November | 0.00 | 0.00 | 0.472147E+10 | 0.448405E+10 | 15149.29 | 09-NOV-09:32 | 12571.15 | 0.00 |
| December | 0.00 | 0.00 | 0.189251E+10 | 0.183308E+10 | 14952.03 | 10-DEC-19:22 | 13028.74 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.881974E+11 | 0.751038E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.116973E+10 | 0.113353E+10 | 6849.37 | 5369.29 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.119320E+11 | 0.982311E+10 | 15937.79 | 13028.74 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 91109599.81 | 81503605.41 | 14591.97 | 14-JAN-22:52 | 13247.70 | 0.00 |
| February | 0.00 | 0.00 | 0.100256E+10 | 0.939109E+09 | 15238.17 | 25-FEB-22:52 | 11516.51 | 0.00 |
| March | 0.00 | 0.00 | 0.418230E+10 | 0.391689E+10 | 15185.46 | 18-MAR-11:52 | 11935.75 | 0.00 |
| April | 0.00 | 0.00 | 0.776186E+10 | 0.732313E+10 | 15244.91 | 24-APR-07:42 | 11251.32 | 0.00 |
| May | 0.00 | 0.00 | 0.108062E+11 | 0.962221E+10 | 15431.74 | 13-MAY-07:52 | 10855.07 | 0.00 |
| June | 0.00 | 0.00 | 0.114037E+11 | 0.954392E+10 | 15511.65 | 18-JUN-06:52 | 10487.92 | 0.00 |
| July | 0.00 | 0.00 | 0.119238E+11 | 0.903859E+10 | 7148.62 | 02-JUL-17:20 | 6260.68 | 0.00 |
| August | 0.00 | 0.00 | 0.110639E+11 | 0.813255E+10 | 6465.64 | 07-AUG-16:13 | 5413.06 | 0.00 |
| September | 0.00 | 0.00 | 0.916521E+10 | 0.692888E+10 | 15272.98 | 27-SEP-07:12 | 11180.46 | 0.00 |
| October | 0.00 | 0.00 | 0.580726E+10 | 0.509905E+10 | 15863.33 | 13-OCT-09:32 | 9334.79 | 0.00 |
| November | 0.00 | 0.00 | 0.231796E+10 | 0.215421E+10 | 15015.89 | 08-NOV-22:52 | 12279.35 | 0.00 |
| December | 0.00 | 0.00 | 0.254129E+09 | 0.240463E+09 | 14647.40 | 16-DEC-20:42 | 13262.16 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.757799E+11 | 0.630205E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 91109599.81 | 81503605.41 | 6465.64 | 5413.06 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.119238E+11 | 0.962221E+10 | 15863.33 | 13262.16 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MSE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.120274E+10 | 0.116569E+10 | 14231.11 | 14-JAN-22:52 | 13143.95 | 0.00 |
| February | 0.00 | 0.00 | 0.253951E+10 | 0.243116E+10 | 14720.69 | 25-FEB-19:22 | 11555.46 | 0.00 |
| March | 0.00 | 0.00 | 0.571971E+10 | 0.541138E+10 | 14785.71 | 18-MAR-11:12 | 11449.72 | 0.00 |
| April | 0.00 | 0.00 | 0.880485E+10 | 0.834551E+10 | 14799.56 | 24-APR-07:42 | 11139.30 | 0.00 |
| May | 0.00 | 0.00 | 0.110670E+11 | 0.988165E+10 | 15012.76 | 13-MAY-07:52 | 10455.22 | 0.00 |
| June | 0.00 | 0.00 | 0.112395E+11 | 0.939100E+10 | 15072.62 | 18-JUN-06:52 | 10097.45 | 0.00 |
| July | 0.00 | 0.00 | 0.119422E+11 | 0.905565E+10 | 6765.36 | 01-JUL-16:01 | 5247.52 | 0.00 |
| August | 0.00 | 0.00 | 0.112668E+11 | 0.833041E+10 | 6374.98 | 27-AUG-16:02 | 4869.50 | 0.00 |
| September | 0.00 | 0.00 | 0.100060E+11 | 0.772667E+10 | 14817.93 | 27-SEP-07:12 | 11033.97 | 0.00 |
| October | 0.00 | 0.00 | 0.793581E+10 | 0.714607E+10 | 15359.62 | 13-OCT-09:12 | 9401.78 | 0.00 |
| November | 0.00 | 0.00 | 0.471426E+10 | 0.447223E+10 | 14589.21 | 09-NOV-09:32 | 12146.11 | 0.00 |
| December | 0.00 | 0.00 | 0.191027E+10 | 0.184933E+10 | 14411.80 | 10-DEC-19:22 | 12425.89 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.883487E+11 | 0.752068E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.120274E+10 | 0.116569E+10 | 6374.98 | 4869.50 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.119422E+11 | 0.988165E+10 | 15359.62 | 13143.95 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MNE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 87884006.41 | 78407769.32 | 14044.15 | 14-JAN-22:52 | 12730.26 | 0.00 |
| February | 0.00 | 0.00 | 0.102103E+10 | 0.955948E+09 | 14606.16 | 25-FEB-17:02 | 11578.69 | 0.00 |
| March | 0.00 | 0.00 | 0.418526E+10 | 0.391372E+10 | 14618.13 | 18-MAR-11:52 | 11543.58 | 0.00 |
| April | 0.00 | 0.00 | 0.780689E+10 | 0.736015E+10 | 14704.28 | 24-APR-07:42 | 10961.48 | 0.00 |
| May | 0.00 | 0.00 | 0.108704E+11 | 0.968156E+10 | 14866.66 | 13-MAY-07:52 | 10457.56 | 0.00 |
| June | 0.00 | 0.00 | 0.112861E+11 | 0.942835E+10 | 14942.01 | 18-JUN-06:52 | 10054.91 | 0.00 |
| July | 0.00 | 0.00 | 0.119330E+11 | 0.904624E+10 | 6572.49 | 01-JUL-16:13 | 5110.82 | 0.00 |
| August | 0.00 | 0.00 | 0.110741E+11 | 0.814129E+10 | 5963.59 | 27-AUG-16:02 | 4520.85 | 0.00 |
| September | 0.00 | 0.00 | 0.913444E+10 | 0.689755E+10 | 14719.51 | 27-SEP-07:12 | 10769.01 | 0.00 |
| October | 0.00 | 0.00 | 0.584485E+10 | 0.512728E+10 | 15281.41 | 13-OCT-09:32 | 9147.88 | 0.00 |
| November | 0.00 | 0.00 | 0.227212E+10 | 0.210674E+10 | 14475.46 | 08-NOV-22:52 | 11733.56 | 0.00 |
| December | 0.00 | 0.00 | 0.232489E+09 | 0.219828E+09 | 14083.29 | 16-DEC-20:42 | 12726.12 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.757486E+11 | 0.629571E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 87884006.41 | 78407769.32 | 5963.59 | 4520.85 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.119330E+11 | 0.968156E+10 | 15281.41 | 12730.26 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.320754E+09 | 0.289611E+09 | 12275.84 | 14-JAN-22:52 | 11250.04 | 0.00 |
| February | 0.00 | 0.00 | 0.121256E+10 | 0.112616E+10 | 12745.76 | 25-FEB-17:02 | 10020.84 | 0.00 |
| March | 0.00 | 0.00 | 0.361489E+10 | 0.335528E+10 | 12741.29 | 18-MAR-11:52 | 10018.42 | 0.00 |
| April | 0.00 | 0.00 | 0.608791E+10 | 0.567863E+10 | 12800.61 | 24-APR-07:42 | 9399.61 | 0.00 |
| May | 0.00 | 0.00 | 0.849263E+10 | 0.740613E+10 | 12947.91 | 13-MAY-07:52 | 9058.78 | 0.00 |
| June | 0.00 | 0.00 | 0.912144E+10 | 0.739541E+10 | 13015.46 | 18-JUN-06:52 | 8761.42 | 0.00 |
| July | 0.00 | 0.00 | 0.992412E+10 | 0.726884E+10 | 5299.68 | 01-JUL-17:13 | 3941.31 | 0.00 |
| August | 0.00 | 0.00 | 0.938422E+10 | 0.665721E+10 | 4889.86 | 27-AUG-16:15 | 3521.75 | 0.00 |
| September | 0.00 | 0.00 | 0.779249E+10 | 0.569615E+10 | 12837.34 | 27-SEP-07:12 | 9278.74 | 0.00 |
| October | 0.00 | 0.00 | 0.496999E+10 | 0.428945E+10 | 13307.52 | 13-OCT-09:32 | 7883.59 | 0.00 |
| November | 0.00 | 0.00 | 0.228595E+10 | 0.210146E+10 | 12627.67 | 08-NOV-22:52 | 10209.79 | 0.00 |
| December | 0.00 | 0.00 | 0.626770E+09 | 0.588627E+09 | 12398.67 | 10-DEC-19:22 | 10549.91 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.638337E+11 | 0.518530E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.320754E+09 | 0.289611E+09 | 4889.86 | 3521.75 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.992412E+10 | 0.740613E+10 | 13307.52 | 11250.04 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MN2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.322587E+09 | 0.291394E+09 | 12266.82 | 14-JAN-22:52 | 11241.04 | 0.00 |
| February | 0.00 | 0.00 | 0.122126E+10 | 0.113451E+10 | 12737.00 | 25-FEB-17:02 | 10016.01 | 0.00 |
| March | 0.00 | 0.00 | 0.362602E+10 | 0.336599E+10 | 12731.60 | 18-MAR-11:52 | 10022.76 | 0.00 |
| April | 0.00 | 0.00 | 0.609235E+10 | 0.568282E+10 | 12791.53 | 24-APR-07:42 | 9394.77 | 0.00 |
| May | 0.00 | 0.00 | 0.849520E+10 | 0.740858E+10 | 12938.54 | 13-MAY-07:52 | 9051.61 | 0.00 |
| June | 0.00 | 0.00 | 0.911820E+10 | 0.739232E+10 | 13006.22 | 18-JUN-06:52 | 8752.54 | 0.00 |
| July | 0.00 | 0.00 | 0.992465E+10 | 0.726931E+10 | 5293.56 | 01-JUL-17:13 | 3936.53 | 0.00 |
| August | 0.00 | 0.00 | 0.938491E+10 | 0.665782E+10 | 4886.33 | 27-AUG-16:15 | 3519.31 | 0.00 |
| September | 0.00 | 0.00 | 0.779180E+10 | 0.569550E+10 | 12828.26 | 27-SEP-07:12 | 9270.10 | 0.00 |
| October | 0.00 | 0.00 | 0.497544E+10 | 0.429452E+10 | 13298.13 | 13-OCT-09:32 | 7879.57 | 0.00 |
| November | 0.00 | 0.00 | 0.229093E+10 | 0.210625E+10 | 12618.47 | 08-NOV-22:52 | 10202.21 | 0.00 |
| December | 0.00 | 0.00 | 0.628227E+09 | 0.590037E+09 | 12389.24 | 10-DEC-19:22 | 10539.65 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.638716E+11 | 0.518890E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.322587E+09 | 0.291394E+09 | 4886.33 | 3519.31 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.992465E+10 | 0.740858E+10 | 13298.13 | 11241.04 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.194297E+10 | 0.187660E+10 | 12668.73 | 17-JAN-20:33 | 10522.24 | 0.00 |
| February | 0.00 | 0.00 | 0.284956E+10 | 0.272010E+10 | 12890.97 | 25-FEB-19:22 | 10159.47 | 0.00 |
| March | 0.00 | 0.00 | 0.515628E+10 | 0.485640E+10 | 12966.53 | 18-MAR-11:12 | 10028.11 | 0.00 |
| April | 0.00 | 0.00 | 0.709253E+10 | 0.666593E+10 | 12965.57 | 24-APR-07:42 | 9608.49 | 0.00 |
| May | 0.00 | 0.00 | 0.869161E+10 | 0.760638E+10 | 13152.04 | 13-MAY-07:52 | 9105.36 | 0.00 |
| June | 0.00 | 0.00 | 0.907309E+10 | 0.735610E+10 | 13206.20 | 18-JUN-06:52 | 8848.93 | 0.00 |
| July | 0.00 | 0.00 | 0.993222E+10 | 0.727652E+10 | 5425.14 | 01-JUL-16:13 | 4023.18 | 0.00 |
| August | 0.00 | 0.00 | 0.958009E+10 | 0.684527E+10 | 5293.50 | 27-AUG-16:02 | 3864.65 | 0.00 |
| September | 0.00 | 0.00 | 0.867976E+10 | 0.652856E+10 | 12994.99 | 27-SEP-07:12 | 9587.70 | 0.00 |
| October | 0.00 | 0.00 | 0.708721E+10 | 0.632455E+10 | 13456.11 | 13-OCT-09:12 | 8202.98 | 0.00 |
| November | 0.00 | 0.00 | 0.477502E+10 | 0.451848E+10 | 12790.28 | 09-NOV-09:32 | 10653.37 | 0.00 |
| December | 0.00 | 0.00 | 0.266735E+10 | 0.258206E+10 | 12784.56 | 29-DEC-22:52 | 9933.06 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.775277E+11 | 0.651569E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.194297E+10 | 0.187660E+10 | 5293.50 | 3864.65 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.993222E+10 | 0.760638E+10 | 13456.11 | 10653.37 | 0.00 |
Report: CoilReportMonthly
For: SPLIT MS2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.194581E+10 | 0.187937E+10 | 12659.94 | 17-JAN-20:33 | 10515.39 | 0.00 |
| February | 0.00 | 0.00 | 0.285732E+10 | 0.272763E+10 | 12880.26 | 25-FEB-19:22 | 10156.61 | 0.00 |
| March | 0.00 | 0.00 | 0.516525E+10 | 0.486509E+10 | 12957.08 | 18-MAR-11:12 | 10021.46 | 0.00 |
| April | 0.00 | 0.00 | 0.709664E+10 | 0.666982E+10 | 12956.60 | 24-APR-07:42 | 9603.40 | 0.00 |
| May | 0.00 | 0.00 | 0.869421E+10 | 0.760884E+10 | 13142.75 | 13-MAY-07:52 | 9098.26 | 0.00 |
| June | 0.00 | 0.00 | 0.906987E+10 | 0.735302E+10 | 13197.04 | 18-JUN-06:52 | 8840.09 | 0.00 |
| July | 0.00 | 0.00 | 0.993277E+10 | 0.727698E+10 | 5421.49 | 01-JUL-16:13 | 4021.01 | 0.00 |
| August | 0.00 | 0.00 | 0.958080E+10 | 0.684588E+10 | 5290.39 | 27-AUG-16:02 | 3862.47 | 0.00 |
| September | 0.00 | 0.00 | 0.867906E+10 | 0.652789E+10 | 12985.96 | 27-SEP-07:12 | 9579.14 | 0.00 |
| October | 0.00 | 0.00 | 0.709141E+10 | 0.632847E+10 | 13446.76 | 13-OCT-09:12 | 8198.31 | 0.00 |
| November | 0.00 | 0.00 | 0.478016E+10 | 0.452347E+10 | 12780.97 | 09-NOV-09:32 | 10646.19 | 0.00 |
| December | 0.00 | 0.00 | 0.267080E+10 | 0.258542E+10 | 12775.40 | 29-DEC-22:52 | 9925.14 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.775641E+11 | 0.651919E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.194581E+10 | 0.187937E+10 | 5290.39 | 3862.47 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.993277E+10 | 0.760884E+10 | 13446.76 | 10646.19 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.253013E+09 | 0.250861E+09 | 8072.12 | 14-JAN-19:32 | 7623.23 | 0.00 |
| February | 0.00 | 0.00 | 0.888451E+09 | 0.865787E+09 | 8382.21 | 25-FEB-15:12 | 7346.36 | 0.00 |
| March | 0.00 | 0.00 | 0.273736E+10 | 0.261305E+10 | 8413.85 | 18-MAR-11:12 | 6499.17 | 0.00 |
| April | 0.00 | 0.00 | 0.476978E+10 | 0.455022E+10 | 8439.61 | 24-APR-07:42 | 6029.33 | 0.00 |
| May | 0.00 | 0.00 | 0.621711E+10 | 0.560826E+10 | 8576.62 | 13-MAY-07:52 | 5876.76 | 0.00 |
| June | 0.00 | 0.00 | 0.643787E+10 | 0.548178E+10 | 8636.78 | 18-JUN-06:52 | 5509.13 | 0.00 |
| July | 0.00 | 0.00 | 0.664511E+10 | 0.513316E+10 | 4629.93 | 02-JUL-16:30 | 4142.68 | 0.00 |
| August | 0.00 | 0.00 | 0.616608E+10 | 0.464371E+10 | 4275.00 | 13-AUG-16:02 | 3488.68 | 0.00 |
| September | 0.00 | 0.00 | 0.533003E+10 | 0.417207E+10 | 8476.44 | 27-SEP-07:12 | 5944.29 | 0.00 |
| October | 0.00 | 0.00 | 0.396747E+10 | 0.360996E+10 | 8762.89 | 13-OCT-09:12 | 5102.81 | 0.00 |
| November | 0.00 | 0.00 | 0.200665E+10 | 0.193507E+10 | 8337.47 | 09-NOV-09:32 | 6659.65 | 0.00 |
| December | 0.00 | 0.00 | 0.462447E+09 | 0.456364E+09 | 8134.55 | 10-DEC-17:22 | 7163.49 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.458814E+11 | 0.393203E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.253013E+09 | 0.250861E+09 | 4275.00 | 3488.68 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.664511E+10 | 0.560826E+10 | 8762.89 | 7623.23 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNW HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 1391951.23 | 1294431.85 | 3927.11 | 14-JAN-22:52 | 3497.14 | 0.00 |
| February | 0.00 | 0.00 | 0.305120E+09 | 0.293444E+09 | 8422.49 | 25-FEB-16:42 | 7055.44 | 0.00 |
| March | 0.00 | 0.00 | 0.197072E+10 | 0.186312E+10 | 8382.18 | 18-MAR-11:52 | 6601.49 | 0.00 |
| April | 0.00 | 0.00 | 0.424257E+10 | 0.402870E+10 | 8445.44 | 24-APR-07:42 | 6006.72 | 0.00 |
| May | 0.00 | 0.00 | 0.611249E+10 | 0.550134E+10 | 8559.40 | 13-MAY-07:52 | 5926.18 | 0.00 |
| June | 0.00 | 0.00 | 0.645844E+10 | 0.549797E+10 | 8625.54 | 18-JUN-06:52 | 5532.17 | 0.00 |
| July | 0.00 | 0.00 | 0.663962E+10 | 0.512766E+10 | 4539.41 | 02-JUL-16:50 | 4079.89 | 0.00 |
| August | 0.00 | 0.00 | 0.606087E+10 | 0.453950E+10 | 4080.39 | 07-AUG-16:20 | 3514.86 | 0.00 |
| September | 0.00 | 0.00 | 0.487058E+10 | 0.373175E+10 | 8481.44 | 27-SEP-07:12 | 5874.27 | 0.00 |
| October | 0.00 | 0.00 | 0.287584E+10 | 0.255386E+10 | 8780.19 | 13-OCT-09:32 | 5038.62 | 0.00 |
| November | 0.00 | 0.00 | 0.862548E+09 | 0.818390E+09 | 8291.39 | 09-NOV-10:32 | 6521.45 | 0.00 |
| December | 0.00 | 0.00 | 17877904.28 | 17654598.77 | 7846.39 | 01-DEC-20:12 | 7846.39 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.404181E+11 | 0.339747E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 1391951.23 | 1294431.85 | 3927.11 | 3497.14 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.663962E+10 | 0.550134E+10 | 8780.19 | 7846.39 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TSE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.228275E+09 | 0.226427E+09 | 7690.75 | 14-JAN-19:32 | 7306.31 | 0.00 |
| February | 0.00 | 0.00 | 0.885312E+09 | 0.862751E+09 | 7970.17 | 25-FEB-15:12 | 6975.43 | 0.00 |
| March | 0.00 | 0.00 | 0.273399E+10 | 0.260739E+10 | 8003.95 | 18-MAR-11:12 | 6216.38 | 0.00 |
| April | 0.00 | 0.00 | 0.479084E+10 | 0.456736E+10 | 8058.19 | 24-APR-07:42 | 5853.40 | 0.00 |
| May | 0.00 | 0.00 | 0.624985E+10 | 0.563863E+10 | 8166.36 | 13-MAY-07:52 | 5595.71 | 0.00 |
| June | 0.00 | 0.00 | 0.637407E+10 | 0.541899E+10 | 8225.84 | 18-JUN-06:52 | 5228.35 | 0.00 |
| July | 0.00 | 0.00 | 0.664691E+10 | 0.513480E+10 | 4155.44 | 01-JUL-16:10 | 3343.84 | 0.00 |
| August | 0.00 | 0.00 | 0.616989E+10 | 0.464728E+10 | 3916.88 | 27-AUG-16:10 | 3126.66 | 0.00 |
| September | 0.00 | 0.00 | 0.531288E+10 | 0.415463E+10 | 8080.01 | 27-SEP-07:12 | 5674.72 | 0.00 |
| October | 0.00 | 0.00 | 0.399050E+10 | 0.362834E+10 | 8353.22 | 13-OCT-09:12 | 4968.77 | 0.00 |
| November | 0.00 | 0.00 | 0.199215E+10 | 0.191922E+10 | 7945.74 | 09-NOV-09:32 | 6424.71 | 0.00 |
| December | 0.00 | 0.00 | 0.438957E+09 | 0.433441E+09 | 7705.18 | 27-DEC-15:02 | 7705.18 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.458136E+11 | 0.392393E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.228275E+09 | 0.226427E+09 | 3916.88 | 3126.66 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.664691E+10 | 0.563863E+10 | 8353.22 | 7705.18 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TNE HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 735938.90 | 694378.46 | 2386.11 | 14-JAN-22:52 | 2123.50 | 0.00 |
| February | 0.00 | 0.00 | 0.292149E+09 | 0.280980E+09 | 7978.57 | 25-FEB-22:52 | 5973.24 | 0.00 |
| March | 0.00 | 0.00 | 0.195161E+10 | 0.184205E+10 | 7970.00 | 18-MAR-11:52 | 6313.23 | 0.00 |
| April | 0.00 | 0.00 | 0.426229E+10 | 0.404400E+10 | 8061.18 | 24-APR-07:42 | 5827.97 | 0.00 |
| May | 0.00 | 0.00 | 0.614571E+10 | 0.553227E+10 | 8146.19 | 13-MAY-07:52 | 5643.55 | 0.00 |
| June | 0.00 | 0.00 | 0.639488E+10 | 0.543548E+10 | 8212.25 | 18-JUN-06:52 | 5248.04 | 0.00 |
| July | 0.00 | 0.00 | 0.664167E+10 | 0.512959E+10 | 4016.96 | 01-JUL-16:20 | 3237.15 | 0.00 |
| August | 0.00 | 0.00 | 0.606503E+10 | 0.454336E+10 | 3708.12 | 07-AUG-16:10 | 3167.42 | 0.00 |
| September | 0.00 | 0.00 | 0.485432E+10 | 0.371468E+10 | 8082.41 | 27-SEP-07:12 | 5603.67 | 0.00 |
| October | 0.00 | 0.00 | 0.289069E+10 | 0.256357E+10 | 8361.47 | 13-OCT-09:32 | 4907.28 | 0.00 |
| November | 0.00 | 0.00 | 0.831706E+09 | 0.787463E+09 | 7902.16 | 09-NOV-10:32 | 6361.39 | 0.00 |
| December | 0.00 | 0.00 | 14023356.61 | 13930795.45 | 7447.66 | 03-DEC-13:42 | 7447.66 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.403448E+11 | 0.338881E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 735938.90 | 694378.46 | 2386.11 | 2123.50 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.664167E+10 | 0.553227E+10 | 8361.47 | 7447.66 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 3910659.51 | 3619919.58 | 5869.65 | 14-JAN-22:52 | 5282.95 | 0.00 |
| February | 0.00 | 0.00 | 0.266793E+09 | 0.252247E+09 | 7205.90 | 25-FEB-22:52 | 5442.55 | 0.00 |
| March | 0.00 | 0.00 | 0.163465E+10 | 0.152803E+10 | 7163.74 | 18-MAR-11:52 | 5650.34 | 0.00 |
| April | 0.00 | 0.00 | 0.338201E+10 | 0.317966E+10 | 7223.58 | 24-APR-07:42 | 5155.49 | 0.00 |
| May | 0.00 | 0.00 | 0.493287E+10 | 0.436943E+10 | 7310.34 | 13-MAY-07:52 | 5089.99 | 0.00 |
| June | 0.00 | 0.00 | 0.529341E+10 | 0.439791E+10 | 7361.41 | 18-JUN-06:52 | 4814.13 | 0.00 |
| July | 0.00 | 0.00 | 0.561841E+10 | 0.422956E+10 | 3316.88 | 01-JUL-16:30 | 2598.21 | 0.00 |
| August | 0.00 | 0.00 | 0.520824E+10 | 0.379350E+10 | 3064.62 | 27-AUG-16:02 | 2346.88 | 0.00 |
| September | 0.00 | 0.00 | 0.417956E+10 | 0.311041E+10 | 7257.07 | 27-SEP-07:12 | 5031.44 | 0.00 |
| October | 0.00 | 0.00 | 0.243479E+10 | 0.212157E+10 | 7504.25 | 13-OCT-09:32 | 4361.09 | 0.00 |
| November | 0.00 | 0.00 | 0.717289E+09 | 0.670605E+09 | 7098.13 | 08-NOV-22:52 | 5746.70 | 0.00 |
| December | 0.00 | 0.00 | 15953380.54 | 15486680.88 | 6653.04 | 01-DEC-15:41 | 6653.04 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.336879E+11 | 0.276720E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 3910659.51 | 3619919.58 | 3064.62 | 2346.88 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.561841E+10 | 0.439791E+10 | 7504.25 | 6653.04 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TN2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 3797198.25 | 3519811.66 | 5698.68 | 14-JAN-22:52 | 5125.43 | 0.00 |
| February | 0.00 | 0.00 | 0.269835E+09 | 0.255248E+09 | 7191.27 | 25-FEB-22:52 | 5431.41 | 0.00 |
| March | 0.00 | 0.00 | 0.164113E+10 | 0.153427E+10 | 7150.13 | 18-MAR-11:52 | 5640.49 | 0.00 |
| April | 0.00 | 0.00 | 0.338490E+10 | 0.318234E+10 | 7210.63 | 24-APR-07:42 | 5146.67 | 0.00 |
| May | 0.00 | 0.00 | 0.493465E+10 | 0.437108E+10 | 7296.87 | 13-MAY-07:52 | 5079.80 | 0.00 |
| June | 0.00 | 0.00 | 0.529159E+10 | 0.439611E+10 | 7347.88 | 18-JUN-06:52 | 4803.38 | 0.00 |
| July | 0.00 | 0.00 | 0.561874E+10 | 0.422981E+10 | 3309.81 | 01-JUL-16:30 | 2592.45 | 0.00 |
| August | 0.00 | 0.00 | 0.520869E+10 | 0.379386E+10 | 3060.50 | 27-AUG-16:02 | 2343.61 | 0.00 |
| September | 0.00 | 0.00 | 0.417933E+10 | 0.311014E+10 | 7243.88 | 27-SEP-07:12 | 5020.22 | 0.00 |
| October | 0.00 | 0.00 | 0.243841E+10 | 0.212492E+10 | 7490.76 | 13-OCT-09:32 | 4355.62 | 0.00 |
| November | 0.00 | 0.00 | 0.720588E+09 | 0.673875E+09 | 7084.71 | 08-NOV-22:52 | 5733.86 | 0.00 |
| December | 0.00 | 0.00 | 15917460.34 | 15471313.47 | 6645.13 | 01-DEC-15:41 | 6645.13 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.337076E+11 | 0.276907E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 3797198.25 | 3519811.66 | 3060.50 | 2343.61 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.561874E+10 | 0.439611E+10 | 7490.76 | 6645.13 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS1 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.284671E+09 | 0.280205E+09 | 6923.29 | 14-JAN-22:52 | 6375.53 | 0.00 |
| February | 0.00 | 0.00 | 0.888220E+09 | 0.860016E+09 | 7166.00 | 25-FEB-15:12 | 6237.19 | 0.00 |
| March | 0.00 | 0.00 | 0.242272E+10 | 0.229736E+10 | 7203.01 | 18-MAR-11:12 | 5580.71 | 0.00 |
| April | 0.00 | 0.00 | 0.391341E+10 | 0.370475E+10 | 7231.71 | 24-APR-07:42 | 5189.76 | 0.00 |
| May | 0.00 | 0.00 | 0.503748E+10 | 0.447656E+10 | 7339.53 | 13-MAY-07:52 | 5055.91 | 0.00 |
| June | 0.00 | 0.00 | 0.527125E+10 | 0.438093E+10 | 7385.07 | 18-JUN-06:52 | 4804.07 | 0.00 |
| July | 0.00 | 0.00 | 0.562287E+10 | 0.423471E+10 | 3442.56 | 01-JUL-16:01 | 2695.12 | 0.00 |
| August | 0.00 | 0.00 | 0.531436E+10 | 0.389798E+10 | 3313.70 | 27-AUG-16:02 | 2564.00 | 0.00 |
| September | 0.00 | 0.00 | 0.464622E+10 | 0.355439E+10 | 7265.01 | 27-SEP-07:12 | 5111.38 | 0.00 |
| October | 0.00 | 0.00 | 0.354476E+10 | 0.319241E+10 | 7503.55 | 13-OCT-09:12 | 4447.16 | 0.00 |
| November | 0.00 | 0.00 | 0.191944E+10 | 0.183920E+10 | 7137.70 | 09-NOV-09:32 | 5811.45 | 0.00 |
| December | 0.00 | 0.00 | 0.522537E+09 | 0.512832E+09 | 7000.21 | 10-DEC-19:22 | 5932.78 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.393879E+11 | 0.332314E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.284671E+09 | 0.280205E+09 | 3313.70 | 2564.00 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.562287E+10 | 0.447656E+10 | 7503.55 | 6375.53 | 0.00 |
Report: CoilReportMonthly
For: SPLIT TS2 HP COOLING COIL
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| HEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
| January | 0.00 | 0.00 | 0.286517E+09 | 0.282068E+09 | 6910.25 | 14-JAN-22:52 | 6361.42 | 0.00 |
| February | 0.00 | 0.00 | 0.893376E+09 | 0.865050E+09 | 7153.04 | 25-FEB-15:12 | 6230.10 | 0.00 |
| March | 0.00 | 0.00 | 0.242855E+10 | 0.230299E+10 | 7189.54 | 18-MAR-11:12 | 5570.90 | 0.00 |
| April | 0.00 | 0.00 | 0.391613E+10 | 0.370729E+10 | 7218.90 | 24-APR-07:42 | 5181.01 | 0.00 |
| May | 0.00 | 0.00 | 0.503929E+10 | 0.447823E+10 | 7326.18 | 13-MAY-07:52 | 5045.84 | 0.00 |
| June | 0.00 | 0.00 | 0.526945E+10 | 0.437915E+10 | 7371.65 | 18-JUN-06:52 | 4793.43 | 0.00 |
| July | 0.00 | 0.00 | 0.562321E+10 | 0.423496E+10 | 3436.92 | 01-JUL-16:01 | 2690.71 | 0.00 |
| August | 0.00 | 0.00 | 0.531481E+10 | 0.389835E+10 | 3309.56 | 27-AUG-16:02 | 2560.64 | 0.00 |
| September | 0.00 | 0.00 | 0.464597E+10 | 0.355411E+10 | 7251.93 | 27-SEP-07:12 | 5100.28 | 0.00 |
| October | 0.00 | 0.00 | 0.354781E+10 | 0.319525E+10 | 7490.12 | 13-OCT-09:12 | 4440.77 | 0.00 |
| November | 0.00 | 0.00 | 0.192301E+10 | 0.184270E+10 | 7124.46 | 09-NOV-09:32 | 5800.95 | 0.00 |
| December | 0.00 | 0.00 | 0.524722E+09 | 0.515037E+09 | 6986.59 | 10-DEC-19:22 | 5917.43 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.394128E+11 | 0.332552E+11 | 0.00 | |||
| Minimum of Months | 0.00 | 0.00 | 0.286517E+09 | 0.282068E+09 | 3309.56 | 2560.64 | 0.00 | |
| Maximum of Months | 0.00 | 0.00 | 0.562321E+10 | 0.447823E+10 | 7490.12 | 6361.42 | 0.00 |
Report: PlantLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 9722.12 | 18573.17 | 17-JAN-07:40 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 9517.46 | 18461.71 | 01-FEB-07:40 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 8903.40 | 17670.54 | 01-MAR-07:50 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 8013.67 | 16121.10 | 01-APR-06:50 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 7098.17 | 14347.62 | 01-MAY-06:50 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 6402.41 | 12719.92 | 01-JUN-06:50 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 6116.84 | 11767.65 | 01-JUL-06:50 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 6322.37 | 12522.05 | 31-AUG-06:40 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 6957.63 | 14019.11 | 30-SEP-06:50 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 7852.83 | 15850.65 | 31-OCT-06:50 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 8765.38 | 17429.35 | 30-NOV-07:50 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 9449.24 | 18417.70 | 31-DEC-07:40 |
| Annual Sum or Average | 0.00 | 7918.02 | ||||
| Minimum of Months | 0.00 | 0.00 | 6116.84 | 11767.65 | ||
| Maximum of Months | 0.00 | 0.00 | 9722.12 | 18573.17 |
Report: FanReportMonthly
For: SPLIT GSW SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 29999556.23 | 0.37 | 408.27 | 03-JAN-14:22 | 0.94 |
| February | 60027037.34 | 0.51 | 408.27 | 01-FEB-13:12 | 0.94 |
| March | 0.152754E+09 | 0.73 | 408.27 | 01-MAR-11:52 | 0.94 |
| April | 0.270095E+09 | 0.97 | 408.27 | 01-APR-07:52 | 0.93 |
| May | 0.371156E+09 | 1.04 | 408.27 | 13-MAY-07:52 | 0.93 |
| June | 0.402786E+09 | 1.03 | 408.27 | 18-JUN-06:52 | 0.93 |
| July | 0.435069E+09 | 1.03 | 262.30 | 02-JUL-16:50 | 0.99 |
| August | 0.424514E+09 | 1.03 | 240.58 | 06-AUG-16:40 | 1.00 |
| September | 0.386220E+09 | 1.03 | 408.27 | 27-SEP-07:12 | 0.93 |
| October | 0.304517E+09 | 0.84 | 408.27 | 01-OCT-07:52 | 0.93 |
| November | 0.178789E+09 | 0.72 | 408.27 | 01-NOV-10:02 | 0.94 |
| December | 71525132.78 | 0.66 | 408.27 | 01-DEC-11:02 | 0.94 |
| Annual Sum or Average | 0.308745E+10 | 0.83 | |||
| Minimum of Months | 29999556.23 | 0.37 | 240.58 | 0.93 | |
| Maximum of Months | 0.435069E+09 | 1.04 | 408.27 | 1.00 |
Report: FanReportMonthly
For: G SW APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.75 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.73 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.73 | 23.17 | 01-AUG-00:10 | 0.73 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.73 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.75 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.73 | 23.17 | 0.73 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: G SW APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.75 | 23.17 | 01-MAR-00:10 | 0.74 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.74 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.74 | 23.17 | 01-AUG-00:10 | 0.74 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.74 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.75 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.74 | 23.17 | 0.74 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: SPLIT GNW SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 1408500.34 | 0.07 | 335.05 | 14-JAN-22:52 | 0.96 |
| February | 18222145.13 | 0.22 | 407.45 | 08-FEB-13:42 | 0.93 |
| March | 0.103893E+09 | 0.67 | 407.45 | 01-MAR-14:22 | 0.94 |
| April | 0.238206E+09 | 0.97 | 407.45 | 01-APR-07:52 | 0.93 |
| May | 0.367031E+09 | 1.04 | 407.45 | 13-MAY-07:52 | 0.93 |
| June | 0.407423E+09 | 1.03 | 407.45 | 18-JUN-06:52 | 0.93 |
| July | 0.438287E+09 | 1.03 | 262.63 | 02-JUL-17:20 | 0.99 |
| August | 0.421710E+09 | 1.03 | 238.55 | 07-AUG-17:10 | 1.00 |
| September | 0.361325E+09 | 1.03 | 407.45 | 27-SEP-07:12 | 0.93 |
| October | 0.238460E+09 | 0.83 | 407.45 | 01-OCT-08:22 | 0.93 |
| November | 0.100726E+09 | 0.65 | 407.45 | 01-NOV-11:02 | 0.94 |
| December | 13175828.76 | 0.28 | 407.45 | 01-DEC-15:41 | 0.94 |
| Annual Sum or Average | 0.270987E+10 | 0.74 | |||
| Minimum of Months | 1408500.34 | 0.07 | 238.55 | 0.93 | |
| Maximum of Months | 0.438287E+09 | 1.04 | 407.45 | 1.00 |
Report: FanReportMonthly
For: G NW APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.74 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.73 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.73 | 23.17 | 01-AUG-00:10 | 0.73 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.73 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.75 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.73 | 23.17 | 0.73 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: G NW APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.74 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.74 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.74 | 23.17 | 01-AUG-00:10 | 0.74 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.74 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.75 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.74 | 23.17 | 0.74 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: SPLIT OFFICE SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.122128E+10 | 0.94 | 476.56 | 01-JAN-00:10 | 0.94 |
| February | 0.110558E+10 | 0.94 | 476.56 | 01-FEB-00:10 | 0.94 |
| March | 0.122777E+10 | 0.94 | 476.56 | 01-MAR-00:10 | 0.94 |
| April | 0.120437E+10 | 0.94 | 476.56 | 01-APR-00:10 | 0.94 |
| May | 0.125113E+10 | 0.93 | 476.56 | 01-MAY-00:10 | 0.94 |
| June | 0.121227E+10 | 0.93 | 476.56 | 01-JUN-00:10 | 0.92 |
| July | 0.125651E+10 | 0.92 | 476.56 | 01-JUL-00:10 | 0.92 |
| August | 0.125387E+10 | 0.92 | 476.56 | 01-AUG-00:10 | 0.92 |
| September | 0.121395E+10 | 0.93 | 476.56 | 01-SEP-00:10 | 0.92 |
| October | 0.124920E+10 | 0.94 | 476.56 | 01-OCT-00:10 | 0.92 |
| November | 0.119957E+10 | 0.94 | 476.56 | 01-NOV-00:10 | 0.93 |
| December | 0.122750E+10 | 0.94 | 476.56 | 01-DEC-00:10 | 0.94 |
| Annual Sum or Average | 0.146230E+11 | 0.94 | |||
| Minimum of Months | 0.110558E+10 | 0.92 | 476.56 | 0.92 | |
| Maximum of Months | 0.125651E+10 | 0.94 | 476.56 | 0.94 |
Report: FanReportMonthly
For: SPLIT GNE SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 1299753.31 | 0.07 | 314.04 | 14-JAN-22:52 | 0.97 |
| February | 18443714.14 | 0.23 | 392.50 | 08-FEB-13:42 | 0.93 |
| March | 0.103183E+09 | 0.68 | 392.50 | 01-MAR-14:22 | 0.94 |
| April | 0.238404E+09 | 0.97 | 392.50 | 01-APR-07:52 | 0.93 |
| May | 0.367132E+09 | 1.04 | 392.50 | 13-MAY-07:52 | 0.93 |
| June | 0.401296E+09 | 1.03 | 392.50 | 18-JUN-06:52 | 0.93 |
| July | 0.436121E+09 | 1.03 | 237.26 | 02-JUL-17:20 | 1.00 |
| August | 0.419686E+09 | 1.03 | 222.73 | 07-AUG-17:10 | 1.00 |
| September | 0.358364E+09 | 1.03 | 392.50 | 27-SEP-07:12 | 0.93 |
| October | 0.238324E+09 | 0.83 | 392.50 | 01-OCT-08:22 | 0.93 |
| November | 99626368.86 | 0.66 | 392.50 | 01-NOV-11:02 | 0.94 |
| December | 12774255.54 | 0.29 | 392.50 | 01-DEC-15:41 | 0.94 |
| Annual Sum or Average | 0.269465E+10 | 0.74 | |||
| Minimum of Months | 1299753.31 | 0.07 | 222.73 | 0.93 | |
| Maximum of Months | 0.436121E+09 | 1.04 | 392.50 | 1.00 |
Report: FanReportMonthly
For: G NE APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.74 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.73 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.73 | 23.17 | 01-AUG-00:10 | 0.73 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.73 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.75 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.73 | 23.17 | 0.73 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: G NE APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.74 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.74 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.74 | 23.17 | 01-AUG-00:10 | 0.74 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.74 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.75 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.74 | 23.17 | 0.74 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: SPLIT GN1 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 5523070.15 | 0.18 | 341.90 | 14-JAN-22:52 | 0.93 |
| February | 23726619.85 | 0.36 | 341.90 | 08-FEB-13:42 | 0.93 |
| March | 96245285.04 | 0.69 | 341.90 | 01-MAR-14:22 | 0.94 |
| April | 0.195646E+09 | 0.97 | 341.90 | 01-APR-07:52 | 0.93 |
| May | 0.296947E+09 | 1.04 | 341.90 | 13-MAY-07:52 | 0.93 |
| June | 0.329976E+09 | 1.03 | 341.90 | 18-JUN-06:52 | 0.93 |
| July | 0.361813E+09 | 1.03 | 190.97 | 02-JUL-17:30 | 1.00 |
| August | 0.349848E+09 | 1.03 | 178.44 | 07-AUG-17:20 | 1.01 |
| September | 0.299090E+09 | 1.03 | 341.90 | 27-SEP-07:12 | 0.93 |
| October | 0.198645E+09 | 0.84 | 341.90 | 01-OCT-08:22 | 0.93 |
| November | 93275425.52 | 0.65 | 341.90 | 01-NOV-11:02 | 0.94 |
| December | 25356784.65 | 0.52 | 341.90 | 01-DEC-15:41 | 0.94 |
| Annual Sum or Average | 0.227609E+10 | 0.78 | |||
| Minimum of Months | 5523070.15 | 0.18 | 178.44 | 0.93 | |
| Maximum of Months | 0.361813E+09 | 1.04 | 341.90 | 1.01 |
Report: FanReportMonthly
For: G N1 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.74 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.73 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.73 | 23.17 | 01-AUG-00:10 | 0.73 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.73 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.75 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.73 | 23.17 | 0.73 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: G N1 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.74 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.74 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.74 | 23.17 | 01-AUG-00:10 | 0.74 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.74 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.75 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.74 | 23.17 | 0.74 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: SPLIT GN2 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 5545185.00 | 0.18 | 341.64 | 14-JAN-22:52 | 0.93 |
| February | 23954834.71 | 0.36 | 341.64 | 07-FEB-13:22 | 0.94 |
| March | 96459307.29 | 0.69 | 341.64 | 01-MAR-14:22 | 0.94 |
| April | 0.195653E+09 | 0.97 | 341.64 | 01-APR-07:52 | 0.93 |
| May | 0.296834E+09 | 1.04 | 341.64 | 13-MAY-07:52 | 0.93 |
| June | 0.329631E+09 | 1.03 | 341.64 | 18-JUN-06:52 | 0.93 |
| July | 0.361612E+09 | 1.03 | 190.50 | 02-JUL-17:30 | 1.00 |
| August | 0.349666E+09 | 1.03 | 178.13 | 07-AUG-17:20 | 1.01 |
| September | 0.298876E+09 | 1.03 | 341.64 | 27-SEP-07:12 | 0.93 |
| October | 0.198632E+09 | 0.84 | 341.64 | 01-OCT-08:22 | 0.93 |
| November | 93371981.88 | 0.65 | 341.64 | 01-NOV-11:02 | 0.94 |
| December | 25373339.50 | 0.52 | 341.64 | 01-DEC-15:41 | 0.94 |
| Annual Sum or Average | 0.227561E+10 | 0.78 | |||
| Minimum of Months | 5545185.00 | 0.18 | 178.13 | 0.93 | |
| Maximum of Months | 0.361612E+09 | 1.04 | 341.64 | 1.01 |
Report: FanReportMonthly
For: G N2 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.74 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.73 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.73 | 23.17 | 01-AUG-00:10 | 0.73 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.73 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.75 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.73 | 23.17 | 0.73 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: G N2 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.74 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.74 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.74 | 23.17 | 01-AUG-00:10 | 0.74 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.74 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.75 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.74 | 23.17 | 0.74 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: SPLIT GS1 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 51181295.79 | 0.65 | 343.35 | 03-JAN-14:22 | 0.94 |
| February | 74098989.51 | 0.64 | 343.35 | 01-FEB-13:12 | 0.94 |
| March | 0.145873E+09 | 0.74 | 343.35 | 01-MAR-11:52 | 0.94 |
| April | 0.227561E+09 | 0.97 | 343.35 | 01-APR-07:52 | 0.93 |
| May | 0.300876E+09 | 1.04 | 343.35 | 13-MAY-07:52 | 0.93 |
| June | 0.324860E+09 | 1.03 | 343.35 | 18-JUN-06:52 | 0.93 |
| July | 0.358037E+09 | 1.03 | 189.71 | 02-JUL-17:10 | 1.01 |
| August | 0.352131E+09 | 1.03 | 184.29 | 27-AUG-16:02 | 1.01 |
| September | 0.323736E+09 | 1.03 | 343.35 | 27-SEP-07:12 | 0.93 |
| October | 0.264098E+09 | 0.84 | 343.35 | 01-OCT-07:52 | 0.93 |
| November | 0.171069E+09 | 0.72 | 343.35 | 01-NOV-10:02 | 0.94 |
| December | 91157243.45 | 0.72 | 343.35 | 01-DEC-11:02 | 0.94 |
| Annual Sum or Average | 0.268468E+10 | 0.87 | |||
| Minimum of Months | 51181295.79 | 0.64 | 184.29 | 0.93 | |
| Maximum of Months | 0.358037E+09 | 1.04 | 343.35 | 1.01 |
Report: FanReportMonthly
For: G S1 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.75 | 23.17 | 01-MAR-00:10 | 0.75 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.73 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.73 | 23.17 | 01-AUG-00:10 | 0.73 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.73 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.75 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.73 | 23.17 | 0.73 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: G S1 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.75 | 23.17 | 01-MAR-00:10 | 0.75 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.74 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.74 | 23.17 | 01-AUG-00:10 | 0.74 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.74 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.75 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.74 | 23.17 | 0.74 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: SPLIT GS2 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 50341504.01 | 0.64 | 346.66 | 03-JAN-14:22 | 0.94 |
| February | 76204852.86 | 0.64 | 346.66 | 01-FEB-13:12 | 0.94 |
| March | 0.154486E+09 | 0.74 | 346.66 | 01-MAR-11:52 | 0.94 |
| April | 0.245885E+09 | 0.97 | 346.66 | 01-APR-07:52 | 0.93 |
| May | 0.324303E+09 | 1.04 | 346.66 | 13-MAY-07:52 | 0.93 |
| June | 0.347463E+09 | 1.03 | 346.66 | 18-JUN-06:52 | 0.93 |
| July | 0.382820E+09 | 1.03 | 202.14 | 02-JUL-17:10 | 1.00 |
| August | 0.375429E+09 | 1.03 | 196.14 | 27-AUG-16:02 | 1.00 |
| September | 0.346142E+09 | 1.03 | 346.66 | 27-SEP-07:12 | 0.93 |
| October | 0.281768E+09 | 0.84 | 346.66 | 01-OCT-07:52 | 0.93 |
| November | 0.180617E+09 | 0.72 | 346.66 | 01-NOV-10:02 | 0.94 |
| December | 92651440.35 | 0.71 | 346.66 | 01-DEC-11:02 | 0.94 |
| Annual Sum or Average | 0.285811E+10 | 0.87 | |||
| Minimum of Months | 50341504.01 | 0.64 | 196.14 | 0.93 | |
| Maximum of Months | 0.382820E+09 | 1.04 | 346.66 | 1.00 |
Report: FanReportMonthly
For: G S2 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.75 | 23.17 | 01-MAR-00:10 | 0.75 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.73 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.73 | 23.17 | 01-AUG-00:10 | 0.73 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.73 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.75 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.73 | 23.17 | 0.73 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: G S2 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.75 | 23.17 | 01-MAR-00:10 | 0.75 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.74 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.74 | 23.17 | 01-AUG-00:10 | 0.74 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.74 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.75 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.74 | 23.17 | 0.74 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: SPLIT MSW SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 83649700.62 | 0.42 | 908.92 | 03-JAN-14:22 | 0.94 |
| February | 0.176285E+09 | 0.59 | 908.92 | 01-FEB-13:12 | 0.94 |
| March | 0.409709E+09 | 0.75 | 908.92 | 01-MAR-11:52 | 0.94 |
| April | 0.648822E+09 | 0.97 | 908.92 | 01-APR-07:52 | 0.93 |
| May | 0.817461E+09 | 1.04 | 908.92 | 13-MAY-07:52 | 0.93 |
| June | 0.830117E+09 | 1.03 | 908.92 | 18-JUN-06:52 | 0.93 |
| July | 0.838497E+09 | 1.04 | 542.49 | 02-JUL-16:40 | 1.00 |
| August | 0.780840E+09 | 1.04 | 481.94 | 06-AUG-16:13 | 1.01 |
| September | 0.700458E+09 | 1.04 | 908.92 | 27-SEP-07:12 | 0.93 |
| October | 0.563204E+09 | 0.85 | 908.92 | 01-OCT-07:52 | 0.93 |
| November | 0.336250E+09 | 0.73 | 908.92 | 01-NOV-10:02 | 0.94 |
| December | 0.135044E+09 | 0.60 | 908.92 | 01-DEC-11:02 | 0.94 |
| Annual Sum or Average | 0.632034E+10 | 0.84 | |||
| Minimum of Months | 83649700.62 | 0.42 | 481.94 | 0.93 | |
| Maximum of Months | 0.838497E+09 | 1.04 | 908.92 | 1.01 |
Report: FanReportMonthly
For: M SW APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.75 | 46.34 | 01-JAN-00:10 | 0.75 |
| February | 0.112112E+09 | 0.75 | 46.34 | 01-FEB-00:10 | 0.75 |
| March | 0.124124E+09 | 0.75 | 46.34 | 01-MAR-00:10 | 0.75 |
| April | 0.120120E+09 | 0.74 | 46.34 | 01-APR-00:10 | 0.74 |
| May | 0.124124E+09 | 0.74 | 46.34 | 01-MAY-00:10 | 0.75 |
| June | 0.120120E+09 | 0.74 | 46.34 | 01-JUN-00:10 | 0.74 |
| July | 0.124124E+09 | 0.73 | 46.34 | 01-JUL-00:10 | 0.74 |
| August | 0.124124E+09 | 0.73 | 46.34 | 01-AUG-00:10 | 0.73 |
| September | 0.120120E+09 | 0.74 | 46.34 | 01-SEP-00:10 | 0.73 |
| October | 0.124124E+09 | 0.74 | 46.34 | 01-OCT-00:10 | 0.74 |
| November | 0.120120E+09 | 0.75 | 46.34 | 01-NOV-00:10 | 0.74 |
| December | 0.124124E+09 | 0.75 | 46.34 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.146145E+10 | 0.74 | |||
| Minimum of Months | 0.112112E+09 | 0.73 | 46.34 | 0.73 | |
| Maximum of Months | 0.124124E+09 | 0.75 | 46.34 | 0.75 |
Report: FanReportMonthly
For: M SW APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.75 | 46.34 | 01-JAN-00:10 | 0.75 |
| February | 0.112112E+09 | 0.75 | 46.34 | 01-FEB-00:10 | 0.75 |
| March | 0.124124E+09 | 0.75 | 46.34 | 01-MAR-00:10 | 0.75 |
| April | 0.120120E+09 | 0.74 | 46.34 | 01-APR-00:10 | 0.74 |
| May | 0.124124E+09 | 0.74 | 46.34 | 01-MAY-00:10 | 0.75 |
| June | 0.120120E+09 | 0.74 | 46.34 | 01-JUN-00:10 | 0.74 |
| July | 0.124124E+09 | 0.74 | 46.34 | 01-JUL-00:10 | 0.74 |
| August | 0.124124E+09 | 0.74 | 46.34 | 01-AUG-00:10 | 0.74 |
| September | 0.120120E+09 | 0.74 | 46.34 | 01-SEP-00:10 | 0.74 |
| October | 0.124124E+09 | 0.74 | 46.34 | 01-OCT-00:10 | 0.74 |
| November | 0.120120E+09 | 0.75 | 46.34 | 01-NOV-00:10 | 0.74 |
| December | 0.124124E+09 | 0.75 | 46.34 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.146145E+10 | 0.74 | |||
| Minimum of Months | 0.112112E+09 | 0.74 | 46.34 | 0.74 | |
| Maximum of Months | 0.124124E+09 | 0.75 | 46.34 | 0.75 |
Report: FanReportMonthly
For: SPLIT MNW SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 6633325.19 | 0.09 | 907.11 | 14-JAN-22:52 | 0.93 |
| February | 72473816.49 | 0.37 | 907.11 | 05-FEB-15:32 | 0.94 |
| March | 0.304732E+09 | 0.71 | 907.11 | 01-MAR-14:22 | 0.94 |
| April | 0.580179E+09 | 0.97 | 907.11 | 01-APR-07:52 | 0.93 |
| May | 0.806823E+09 | 1.04 | 907.11 | 13-MAY-07:52 | 0.93 |
| June | 0.837112E+09 | 1.03 | 907.11 | 18-JUN-06:52 | 0.93 |
| July | 0.841845E+09 | 1.04 | 537.27 | 02-JUL-17:10 | 1.00 |
| August | 0.771008E+09 | 1.04 | 470.39 | 07-AUG-16:13 | 1.01 |
| September | 0.642762E+09 | 1.04 | 907.11 | 27-SEP-07:12 | 0.93 |
| October | 0.419419E+09 | 0.83 | 907.11 | 01-OCT-08:22 | 0.93 |
| November | 0.168634E+09 | 0.61 | 907.11 | 01-NOV-11:02 | 0.94 |
| December | 18480835.58 | 0.17 | 907.11 | 01-DEC-15:41 | 0.94 |
| Annual Sum or Average | 0.547010E+10 | 0.75 | |||
| Minimum of Months | 6633325.19 | 0.09 | 470.39 | 0.93 | |
| Maximum of Months | 0.841845E+09 | 1.04 | 907.11 | 1.01 |
Report: FanReportMonthly
For: M NW APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.75 | 46.34 | 01-JAN-00:10 | 0.75 |
| February | 0.112112E+09 | 0.75 | 46.34 | 01-FEB-00:10 | 0.75 |
| March | 0.124124E+09 | 0.74 | 46.34 | 01-MAR-00:10 | 0.75 |
| April | 0.120120E+09 | 0.74 | 46.34 | 01-APR-00:10 | 0.74 |
| May | 0.124124E+09 | 0.74 | 46.34 | 01-MAY-00:10 | 0.75 |
| June | 0.120120E+09 | 0.74 | 46.34 | 01-JUN-00:10 | 0.74 |
| July | 0.124124E+09 | 0.73 | 46.34 | 01-JUL-00:10 | 0.74 |
| August | 0.124124E+09 | 0.73 | 46.34 | 01-AUG-00:10 | 0.73 |
| September | 0.120120E+09 | 0.74 | 46.34 | 01-SEP-00:10 | 0.73 |
| October | 0.124124E+09 | 0.74 | 46.34 | 01-OCT-00:10 | 0.74 |
| November | 0.120120E+09 | 0.75 | 46.34 | 01-NOV-00:10 | 0.74 |
| December | 0.124124E+09 | 0.75 | 46.34 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.146145E+10 | 0.74 | |||
| Minimum of Months | 0.112112E+09 | 0.73 | 46.34 | 0.73 | |
| Maximum of Months | 0.124124E+09 | 0.75 | 46.34 | 0.75 |
Report: FanReportMonthly
For: M NW APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.75 | 46.34 | 01-JAN-00:10 | 0.75 |
| February | 0.112112E+09 | 0.75 | 46.34 | 01-FEB-00:10 | 0.75 |
| March | 0.124124E+09 | 0.75 | 46.34 | 01-MAR-00:10 | 0.74 |
| April | 0.120120E+09 | 0.74 | 46.34 | 01-APR-00:10 | 0.74 |
| May | 0.124124E+09 | 0.74 | 46.34 | 01-MAY-00:10 | 0.75 |
| June | 0.120120E+09 | 0.74 | 46.34 | 01-JUN-00:10 | 0.74 |
| July | 0.124124E+09 | 0.74 | 46.34 | 01-JUL-00:10 | 0.74 |
| August | 0.124124E+09 | 0.74 | 46.34 | 01-AUG-00:10 | 0.74 |
| September | 0.120120E+09 | 0.74 | 46.34 | 01-SEP-00:10 | 0.74 |
| October | 0.124124E+09 | 0.74 | 46.34 | 01-OCT-00:10 | 0.74 |
| November | 0.120120E+09 | 0.75 | 46.34 | 01-NOV-00:10 | 0.74 |
| December | 0.124124E+09 | 0.75 | 46.34 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.146145E+10 | 0.74 | |||
| Minimum of Months | 0.112112E+09 | 0.74 | 46.34 | 0.74 | |
| Maximum of Months | 0.124124E+09 | 0.75 | 46.34 | 0.75 |
Report: FanReportMonthly
For: SPLIT MSE SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 85751157.02 | 0.43 | 872.08 | 03-JAN-14:22 | 0.94 |
| February | 0.178934E+09 | 0.59 | 872.08 | 01-FEB-13:12 | 0.94 |
| March | 0.408655E+09 | 0.76 | 872.08 | 01-MAR-11:52 | 0.94 |
| April | 0.647913E+09 | 0.97 | 872.08 | 01-APR-07:52 | 0.93 |
| May | 0.816925E+09 | 1.04 | 872.08 | 13-MAY-07:52 | 0.93 |
| June | 0.816493E+09 | 1.03 | 872.08 | 18-JUN-06:52 | 0.93 |
| July | 0.833964E+09 | 1.04 | 478.56 | 01-JUL-16:01 | 1.00 |
| August | 0.776823E+09 | 1.04 | 443.11 | 27-AUG-16:02 | 1.01 |
| September | 0.694142E+09 | 1.04 | 872.08 | 27-SEP-07:12 | 0.93 |
| October | 0.562768E+09 | 0.85 | 872.08 | 01-OCT-07:52 | 0.93 |
| November | 0.333542E+09 | 0.73 | 872.08 | 01-NOV-10:02 | 0.94 |
| December | 0.135637E+09 | 0.61 | 872.08 | 01-DEC-11:02 | 0.94 |
| Annual Sum or Average | 0.629155E+10 | 0.85 | |||
| Minimum of Months | 85751157.02 | 0.43 | 443.11 | 0.93 | |
| Maximum of Months | 0.833964E+09 | 1.04 | 872.08 | 1.01 |
Report: FanReportMonthly
For: M SE APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.75 | 46.34 | 01-JAN-00:10 | 0.75 |
| February | 0.112112E+09 | 0.75 | 46.34 | 01-FEB-00:10 | 0.75 |
| March | 0.124124E+09 | 0.75 | 46.34 | 01-MAR-00:10 | 0.75 |
| April | 0.120120E+09 | 0.74 | 46.34 | 01-APR-00:10 | 0.74 |
| May | 0.124124E+09 | 0.74 | 46.34 | 01-MAY-00:10 | 0.75 |
| June | 0.120120E+09 | 0.74 | 46.34 | 01-JUN-00:10 | 0.74 |
| July | 0.124124E+09 | 0.73 | 46.34 | 01-JUL-00:10 | 0.74 |
| August | 0.124124E+09 | 0.73 | 46.34 | 01-AUG-00:10 | 0.73 |
| September | 0.120120E+09 | 0.74 | 46.34 | 01-SEP-00:10 | 0.73 |
| October | 0.124124E+09 | 0.74 | 46.34 | 01-OCT-00:10 | 0.74 |
| November | 0.120120E+09 | 0.75 | 46.34 | 01-NOV-00:10 | 0.74 |
| December | 0.124124E+09 | 0.75 | 46.34 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.146145E+10 | 0.74 | |||
| Minimum of Months | 0.112112E+09 | 0.73 | 46.34 | 0.73 | |
| Maximum of Months | 0.124124E+09 | 0.75 | 46.34 | 0.75 |
Report: FanReportMonthly
For: M SE APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.75 | 46.34 | 01-JAN-00:10 | 0.75 |
| February | 0.112112E+09 | 0.75 | 46.34 | 01-FEB-00:10 | 0.75 |
| March | 0.124124E+09 | 0.75 | 46.34 | 01-MAR-00:10 | 0.75 |
| April | 0.120120E+09 | 0.74 | 46.34 | 01-APR-00:10 | 0.74 |
| May | 0.124124E+09 | 0.74 | 46.34 | 01-MAY-00:10 | 0.75 |
| June | 0.120120E+09 | 0.74 | 46.34 | 01-JUN-00:10 | 0.74 |
| July | 0.124124E+09 | 0.74 | 46.34 | 01-JUL-00:10 | 0.74 |
| August | 0.124124E+09 | 0.74 | 46.34 | 01-AUG-00:10 | 0.74 |
| September | 0.120120E+09 | 0.74 | 46.34 | 01-SEP-00:10 | 0.74 |
| October | 0.124124E+09 | 0.74 | 46.34 | 01-OCT-00:10 | 0.74 |
| November | 0.120120E+09 | 0.75 | 46.34 | 01-NOV-00:10 | 0.74 |
| December | 0.124124E+09 | 0.75 | 46.34 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.146145E+10 | 0.74 | |||
| Minimum of Months | 0.112112E+09 | 0.74 | 46.34 | 0.74 | |
| Maximum of Months | 0.124124E+09 | 0.75 | 46.34 | 0.75 |
Report: FanReportMonthly
For: SPLIT MNE SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 6420956.72 | 0.10 | 870.33 | 14-JAN-22:52 | 0.93 |
| February | 73513930.77 | 0.39 | 870.33 | 05-FEB-15:32 | 0.94 |
| March | 0.303382E+09 | 0.72 | 870.33 | 01-MAR-14:22 | 0.94 |
| April | 0.580166E+09 | 0.97 | 870.33 | 01-APR-07:52 | 0.93 |
| May | 0.806875E+09 | 1.04 | 870.33 | 13-MAY-07:52 | 0.93 |
| June | 0.823892E+09 | 1.03 | 870.33 | 18-JUN-06:52 | 0.93 |
| July | 0.837814E+09 | 1.04 | 471.69 | 02-JUL-17:20 | 1.01 |
| August | 0.767576E+09 | 1.04 | 430.85 | 07-AUG-16:20 | 1.01 |
| September | 0.637345E+09 | 1.04 | 870.33 | 27-SEP-07:12 | 0.93 |
| October | 0.419782E+09 | 0.83 | 870.33 | 01-OCT-08:22 | 0.93 |
| November | 0.164491E+09 | 0.62 | 870.33 | 01-NOV-11:02 | 0.94 |
| December | 16853989.90 | 0.17 | 870.33 | 01-DEC-15:41 | 0.94 |
| Annual Sum or Average | 0.543811E+10 | 0.75 | |||
| Minimum of Months | 6420956.72 | 0.10 | 430.85 | 0.93 | |
| Maximum of Months | 0.837814E+09 | 1.04 | 870.33 | 1.01 |
Report: FanReportMonthly
For: M NE APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.75 | 46.34 | 01-JAN-00:10 | 0.75 |
| February | 0.112112E+09 | 0.75 | 46.34 | 01-FEB-00:10 | 0.75 |
| March | 0.124124E+09 | 0.74 | 46.34 | 01-MAR-00:10 | 0.74 |
| April | 0.120120E+09 | 0.74 | 46.34 | 01-APR-00:10 | 0.74 |
| May | 0.124124E+09 | 0.74 | 46.34 | 01-MAY-00:10 | 0.75 |
| June | 0.120120E+09 | 0.74 | 46.34 | 01-JUN-00:10 | 0.74 |
| July | 0.124124E+09 | 0.73 | 46.34 | 01-JUL-00:10 | 0.74 |
| August | 0.124124E+09 | 0.73 | 46.34 | 01-AUG-00:10 | 0.73 |
| September | 0.120120E+09 | 0.74 | 46.34 | 01-SEP-00:10 | 0.73 |
| October | 0.124124E+09 | 0.74 | 46.34 | 01-OCT-00:10 | 0.74 |
| November | 0.120120E+09 | 0.75 | 46.34 | 01-NOV-00:10 | 0.74 |
| December | 0.124124E+09 | 0.75 | 46.34 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.146145E+10 | 0.74 | |||
| Minimum of Months | 0.112112E+09 | 0.73 | 46.34 | 0.73 | |
| Maximum of Months | 0.124124E+09 | 0.75 | 46.34 | 0.75 |
Report: FanReportMonthly
For: M NE APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.75 | 46.34 | 01-JAN-00:10 | 0.75 |
| February | 0.112112E+09 | 0.75 | 46.34 | 01-FEB-00:10 | 0.75 |
| March | 0.124124E+09 | 0.75 | 46.34 | 01-MAR-00:10 | 0.74 |
| April | 0.120120E+09 | 0.74 | 46.34 | 01-APR-00:10 | 0.74 |
| May | 0.124124E+09 | 0.74 | 46.34 | 01-MAY-00:10 | 0.75 |
| June | 0.120120E+09 | 0.74 | 46.34 | 01-JUN-00:10 | 0.74 |
| July | 0.124124E+09 | 0.74 | 46.34 | 01-JUL-00:10 | 0.74 |
| August | 0.124124E+09 | 0.74 | 46.34 | 01-AUG-00:10 | 0.74 |
| September | 0.120120E+09 | 0.74 | 46.34 | 01-SEP-00:10 | 0.74 |
| October | 0.124124E+09 | 0.74 | 46.34 | 01-OCT-00:10 | 0.74 |
| November | 0.120120E+09 | 0.75 | 46.34 | 01-NOV-00:10 | 0.74 |
| December | 0.124124E+09 | 0.75 | 46.34 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.146145E+10 | 0.74 | |||
| Minimum of Months | 0.112112E+09 | 0.74 | 46.34 | 0.74 | |
| Maximum of Months | 0.124124E+09 | 0.75 | 46.34 | 0.75 |
Report: FanReportMonthly
For: SPLIT MN1 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 22942566.82 | 0.26 | 748.25 | 13-JAN-22:52 | 0.93 |
| February | 86167114.82 | 0.50 | 748.25 | 01-FEB-20:12 | 0.94 |
| March | 0.258220E+09 | 0.71 | 748.25 | 01-MAR-14:22 | 0.94 |
| April | 0.446943E+09 | 0.97 | 748.25 | 01-APR-07:52 | 0.93 |
| May | 0.621601E+09 | 1.04 | 748.25 | 13-MAY-07:52 | 0.93 |
| June | 0.654674E+09 | 1.04 | 748.25 | 18-JUN-06:52 | 0.93 |
| July | 0.684258E+09 | 1.04 | 371.74 | 02-JUL-17:40 | 1.01 |
| August | 0.638267E+09 | 1.04 | 337.13 | 07-AUG-17:20 | 1.02 |
| September | 0.533502E+09 | 1.04 | 748.25 | 27-SEP-07:12 | 0.93 |
| October | 0.351161E+09 | 0.83 | 748.25 | 01-OCT-08:22 | 0.93 |
| November | 0.163064E+09 | 0.65 | 748.25 | 01-NOV-11:02 | 0.94 |
| December | 45140998.13 | 0.48 | 748.25 | 01-DEC-15:41 | 0.94 |
| Annual Sum or Average | 0.450594E+10 | 0.80 | |||
| Minimum of Months | 22942566.82 | 0.26 | 337.13 | 0.93 | |
| Maximum of Months | 0.684258E+09 | 1.04 | 748.25 | 1.02 |
Report: FanReportMonthly
For: M N1 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.75 | 46.34 | 01-JAN-00:10 | 0.75 |
| February | 0.112112E+09 | 0.75 | 46.34 | 01-FEB-00:10 | 0.75 |
| March | 0.124124E+09 | 0.74 | 46.34 | 01-MAR-00:10 | 0.75 |
| April | 0.120120E+09 | 0.74 | 46.34 | 01-APR-00:10 | 0.74 |
| May | 0.124124E+09 | 0.74 | 46.34 | 01-MAY-00:10 | 0.75 |
| June | 0.120120E+09 | 0.74 | 46.34 | 01-JUN-00:10 | 0.74 |
| July | 0.124124E+09 | 0.73 | 46.34 | 01-JUL-00:10 | 0.74 |
| August | 0.124124E+09 | 0.73 | 46.34 | 01-AUG-00:10 | 0.73 |
| September | 0.120120E+09 | 0.74 | 46.34 | 01-SEP-00:10 | 0.73 |
| October | 0.124124E+09 | 0.74 | 46.34 | 01-OCT-00:10 | 0.74 |
| November | 0.120120E+09 | 0.75 | 46.34 | 01-NOV-00:10 | 0.74 |
| December | 0.124124E+09 | 0.75 | 46.34 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.146145E+10 | 0.74 | |||
| Minimum of Months | 0.112112E+09 | 0.73 | 46.34 | 0.73 | |
| Maximum of Months | 0.124124E+09 | 0.75 | 46.34 | 0.75 |
Report: FanReportMonthly
For: M N1 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.75 | 46.34 | 01-JAN-00:10 | 0.75 |
| February | 0.112112E+09 | 0.75 | 46.34 | 01-FEB-00:10 | 0.75 |
| March | 0.124124E+09 | 0.74 | 46.34 | 01-MAR-00:10 | 0.74 |
| April | 0.120120E+09 | 0.74 | 46.34 | 01-APR-00:10 | 0.74 |
| May | 0.124124E+09 | 0.74 | 46.34 | 01-MAY-00:10 | 0.75 |
| June | 0.120120E+09 | 0.74 | 46.34 | 01-JUN-00:10 | 0.74 |
| July | 0.124124E+09 | 0.74 | 46.34 | 01-JUL-00:10 | 0.74 |
| August | 0.124124E+09 | 0.74 | 46.34 | 01-AUG-00:10 | 0.74 |
| September | 0.120120E+09 | 0.74 | 46.34 | 01-SEP-00:10 | 0.74 |
| October | 0.124124E+09 | 0.74 | 46.34 | 01-OCT-00:10 | 0.74 |
| November | 0.120120E+09 | 0.75 | 46.34 | 01-NOV-00:10 | 0.74 |
| December | 0.124124E+09 | 0.75 | 46.34 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.146145E+10 | 0.74 | |||
| Minimum of Months | 0.112112E+09 | 0.74 | 46.34 | 0.74 | |
| Maximum of Months | 0.124124E+09 | 0.75 | 46.34 | 0.75 |
Report: FanReportMonthly
For: SPLIT MN2 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 23074559.29 | 0.26 | 747.65 | 13-JAN-22:52 | 0.93 |
| February | 86773242.68 | 0.50 | 747.65 | 01-FEB-20:12 | 0.94 |
| March | 0.258967E+09 | 0.71 | 747.65 | 01-MAR-14:22 | 0.94 |
| April | 0.447214E+09 | 0.97 | 747.65 | 01-APR-07:52 | 0.93 |
| May | 0.621728E+09 | 1.04 | 747.65 | 13-MAY-07:52 | 0.93 |
| June | 0.654378E+09 | 1.04 | 747.65 | 18-JUN-06:52 | 0.93 |
| July | 0.684221E+09 | 1.04 | 370.83 | 02-JUL-17:40 | 1.01 |
| August | 0.638246E+09 | 1.04 | 336.61 | 07-AUG-17:20 | 1.02 |
| September | 0.533401E+09 | 1.04 | 747.65 | 27-SEP-07:12 | 0.93 |
| October | 0.351506E+09 | 0.83 | 747.65 | 01-OCT-08:22 | 0.93 |
| November | 0.163396E+09 | 0.65 | 747.65 | 01-NOV-11:02 | 0.94 |
| December | 45243505.75 | 0.48 | 747.65 | 01-DEC-15:41 | 0.94 |
| Annual Sum or Average | 0.450815E+10 | 0.80 | |||
| Minimum of Months | 23074559.29 | 0.26 | 336.61 | 0.93 | |
| Maximum of Months | 0.684221E+09 | 1.04 | 747.65 | 1.02 |
Report: FanReportMonthly
For: M N2 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.75 | 46.34 | 01-JAN-00:10 | 0.75 |
| February | 0.112112E+09 | 0.75 | 46.34 | 01-FEB-00:10 | 0.75 |
| March | 0.124124E+09 | 0.74 | 46.34 | 01-MAR-00:10 | 0.75 |
| April | 0.120120E+09 | 0.74 | 46.34 | 01-APR-00:10 | 0.74 |
| May | 0.124124E+09 | 0.74 | 46.34 | 01-MAY-00:10 | 0.75 |
| June | 0.120120E+09 | 0.74 | 46.34 | 01-JUN-00:10 | 0.74 |
| July | 0.124124E+09 | 0.73 | 46.34 | 01-JUL-00:10 | 0.74 |
| August | 0.124124E+09 | 0.73 | 46.34 | 01-AUG-00:10 | 0.73 |
| September | 0.120120E+09 | 0.74 | 46.34 | 01-SEP-00:10 | 0.73 |
| October | 0.124124E+09 | 0.74 | 46.34 | 01-OCT-00:10 | 0.74 |
| November | 0.120120E+09 | 0.75 | 46.34 | 01-NOV-00:10 | 0.74 |
| December | 0.124124E+09 | 0.75 | 46.34 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.146145E+10 | 0.74 | |||
| Minimum of Months | 0.112112E+09 | 0.73 | 46.34 | 0.73 | |
| Maximum of Months | 0.124124E+09 | 0.75 | 46.34 | 0.75 |
Report: FanReportMonthly
For: M N2 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.75 | 46.34 | 01-JAN-00:10 | 0.75 |
| February | 0.112112E+09 | 0.75 | 46.34 | 01-FEB-00:10 | 0.75 |
| March | 0.124124E+09 | 0.74 | 46.34 | 01-MAR-00:10 | 0.74 |
| April | 0.120120E+09 | 0.74 | 46.34 | 01-APR-00:10 | 0.74 |
| May | 0.124124E+09 | 0.74 | 46.34 | 01-MAY-00:10 | 0.75 |
| June | 0.120120E+09 | 0.74 | 46.34 | 01-JUN-00:10 | 0.74 |
| July | 0.124124E+09 | 0.74 | 46.34 | 01-JUL-00:10 | 0.74 |
| August | 0.124124E+09 | 0.74 | 46.34 | 01-AUG-00:10 | 0.74 |
| September | 0.120120E+09 | 0.74 | 46.34 | 01-SEP-00:10 | 0.74 |
| October | 0.124124E+09 | 0.74 | 46.34 | 01-OCT-00:10 | 0.74 |
| November | 0.120120E+09 | 0.75 | 46.34 | 01-NOV-00:10 | 0.74 |
| December | 0.124124E+09 | 0.75 | 46.34 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.146145E+10 | 0.74 | |||
| Minimum of Months | 0.112112E+09 | 0.74 | 46.34 | 0.74 | |
| Maximum of Months | 0.124124E+09 | 0.75 | 46.34 | 0.75 |
Report: FanReportMonthly
For: SPLIT MS1 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.136526E+09 | 0.70 | 751.07 | 02-JAN-18:42 | 0.93 |
| February | 0.197318E+09 | 0.66 | 751.07 | 01-FEB-13:12 | 0.94 |
| March | 0.361532E+09 | 0.76 | 751.07 | 01-MAR-11:52 | 0.94 |
| April | 0.513684E+09 | 0.97 | 751.07 | 01-APR-07:52 | 0.93 |
| May | 0.630433E+09 | 1.04 | 751.07 | 13-MAY-07:52 | 0.93 |
| June | 0.645595E+09 | 1.04 | 751.07 | 18-JUN-06:52 | 0.93 |
| July | 0.678579E+09 | 1.04 | 375.87 | 01-JUL-16:13 | 1.01 |
| August | 0.645834E+09 | 1.04 | 359.55 | 27-AUG-16:02 | 1.01 |
| September | 0.589130E+09 | 1.04 | 751.07 | 27-SEP-07:12 | 0.93 |
| October | 0.492623E+09 | 0.85 | 751.07 | 01-OCT-07:52 | 0.93 |
| November | 0.330985E+09 | 0.73 | 751.07 | 01-NOV-10:02 | 0.94 |
| December | 0.186511E+09 | 0.71 | 751.07 | 01-DEC-11:02 | 0.94 |
| Annual Sum or Average | 0.540875E+10 | 0.88 | |||
| Minimum of Months | 0.136526E+09 | 0.66 | 359.55 | 0.93 | |
| Maximum of Months | 0.678579E+09 | 1.04 | 751.07 | 1.01 |
Report: FanReportMonthly
For: M S1 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.75 | 46.34 | 01-JAN-00:10 | 0.75 |
| February | 0.112112E+09 | 0.75 | 46.34 | 01-FEB-00:10 | 0.75 |
| March | 0.124124E+09 | 0.75 | 46.34 | 01-MAR-00:10 | 0.75 |
| April | 0.120120E+09 | 0.74 | 46.34 | 01-APR-00:10 | 0.74 |
| May | 0.124124E+09 | 0.74 | 46.34 | 01-MAY-00:10 | 0.75 |
| June | 0.120120E+09 | 0.74 | 46.34 | 01-JUN-00:10 | 0.74 |
| July | 0.124124E+09 | 0.73 | 46.34 | 01-JUL-00:10 | 0.74 |
| August | 0.124124E+09 | 0.73 | 46.34 | 01-AUG-00:10 | 0.73 |
| September | 0.120120E+09 | 0.74 | 46.34 | 01-SEP-00:10 | 0.73 |
| October | 0.124124E+09 | 0.74 | 46.34 | 01-OCT-00:10 | 0.74 |
| November | 0.120120E+09 | 0.75 | 46.34 | 01-NOV-00:10 | 0.74 |
| December | 0.124124E+09 | 0.75 | 46.34 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.146145E+10 | 0.74 | |||
| Minimum of Months | 0.112112E+09 | 0.73 | 46.34 | 0.73 | |
| Maximum of Months | 0.124124E+09 | 0.75 | 46.34 | 0.75 |
Report: FanReportMonthly
For: M S1 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.75 | 46.34 | 01-JAN-00:10 | 0.75 |
| February | 0.112112E+09 | 0.75 | 46.34 | 01-FEB-00:10 | 0.75 |
| March | 0.124124E+09 | 0.75 | 46.34 | 01-MAR-00:10 | 0.75 |
| April | 0.120120E+09 | 0.74 | 46.34 | 01-APR-00:10 | 0.74 |
| May | 0.124124E+09 | 0.74 | 46.34 | 01-MAY-00:10 | 0.75 |
| June | 0.120120E+09 | 0.74 | 46.34 | 01-JUN-00:10 | 0.74 |
| July | 0.124124E+09 | 0.74 | 46.34 | 01-JUL-00:10 | 0.74 |
| August | 0.124124E+09 | 0.74 | 46.34 | 01-AUG-00:10 | 0.74 |
| September | 0.120120E+09 | 0.74 | 46.34 | 01-SEP-00:10 | 0.74 |
| October | 0.124124E+09 | 0.74 | 46.34 | 01-OCT-00:10 | 0.74 |
| November | 0.120120E+09 | 0.75 | 46.34 | 01-NOV-00:10 | 0.74 |
| December | 0.124124E+09 | 0.75 | 46.34 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.146145E+10 | 0.74 | |||
| Minimum of Months | 0.112112E+09 | 0.74 | 46.34 | 0.74 | |
| Maximum of Months | 0.124124E+09 | 0.75 | 46.34 | 0.75 |
Report: FanReportMonthly
For: SPLIT MS2 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.136706E+09 | 0.70 | 750.46 | 02-JAN-18:42 | 0.93 |
| February | 0.197815E+09 | 0.66 | 750.46 | 01-FEB-13:12 | 0.94 |
| March | 0.362089E+09 | 0.76 | 750.46 | 01-MAR-11:52 | 0.94 |
| April | 0.513901E+09 | 0.97 | 750.46 | 01-APR-07:52 | 0.93 |
| May | 0.630545E+09 | 1.04 | 750.46 | 13-MAY-07:52 | 0.93 |
| June | 0.645291E+09 | 1.04 | 750.46 | 18-JUN-06:52 | 0.93 |
| July | 0.678530E+09 | 1.04 | 375.59 | 01-JUL-16:13 | 1.01 |
| August | 0.645799E+09 | 1.04 | 359.31 | 27-AUG-16:02 | 1.01 |
| September | 0.589008E+09 | 1.04 | 750.46 | 27-SEP-07:12 | 0.93 |
| October | 0.492837E+09 | 0.85 | 750.46 | 01-OCT-07:52 | 0.93 |
| November | 0.331278E+09 | 0.73 | 750.46 | 01-NOV-10:02 | 0.94 |
| December | 0.186725E+09 | 0.71 | 750.46 | 01-DEC-11:02 | 0.94 |
| Annual Sum or Average | 0.541053E+10 | 0.88 | |||
| Minimum of Months | 0.136706E+09 | 0.66 | 359.31 | 0.93 | |
| Maximum of Months | 0.678530E+09 | 1.04 | 750.46 | 1.01 |
Report: FanReportMonthly
For: M S2 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.75 | 46.34 | 01-JAN-00:10 | 0.75 |
| February | 0.112112E+09 | 0.75 | 46.34 | 01-FEB-00:10 | 0.75 |
| March | 0.124124E+09 | 0.75 | 46.34 | 01-MAR-00:10 | 0.75 |
| April | 0.120120E+09 | 0.74 | 46.34 | 01-APR-00:10 | 0.74 |
| May | 0.124124E+09 | 0.74 | 46.34 | 01-MAY-00:10 | 0.75 |
| June | 0.120120E+09 | 0.74 | 46.34 | 01-JUN-00:10 | 0.74 |
| July | 0.124124E+09 | 0.73 | 46.34 | 01-JUL-00:10 | 0.74 |
| August | 0.124124E+09 | 0.73 | 46.34 | 01-AUG-00:10 | 0.73 |
| September | 0.120120E+09 | 0.74 | 46.34 | 01-SEP-00:10 | 0.73 |
| October | 0.124124E+09 | 0.74 | 46.34 | 01-OCT-00:10 | 0.74 |
| November | 0.120120E+09 | 0.75 | 46.34 | 01-NOV-00:10 | 0.74 |
| December | 0.124124E+09 | 0.75 | 46.34 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.146145E+10 | 0.74 | |||
| Minimum of Months | 0.112112E+09 | 0.73 | 46.34 | 0.73 | |
| Maximum of Months | 0.124124E+09 | 0.75 | 46.34 | 0.75 |
Report: FanReportMonthly
For: M S2 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 0.124124E+09 | 0.75 | 46.34 | 01-JAN-00:10 | 0.75 |
| February | 0.112112E+09 | 0.75 | 46.34 | 01-FEB-00:10 | 0.75 |
| March | 0.124124E+09 | 0.75 | 46.34 | 01-MAR-00:10 | 0.75 |
| April | 0.120120E+09 | 0.74 | 46.34 | 01-APR-00:10 | 0.74 |
| May | 0.124124E+09 | 0.74 | 46.34 | 01-MAY-00:10 | 0.75 |
| June | 0.120120E+09 | 0.74 | 46.34 | 01-JUN-00:10 | 0.74 |
| July | 0.124124E+09 | 0.74 | 46.34 | 01-JUL-00:10 | 0.74 |
| August | 0.124124E+09 | 0.74 | 46.34 | 01-AUG-00:10 | 0.74 |
| September | 0.120120E+09 | 0.74 | 46.34 | 01-SEP-00:10 | 0.74 |
| October | 0.124124E+09 | 0.74 | 46.34 | 01-OCT-00:10 | 0.74 |
| November | 0.120120E+09 | 0.75 | 46.34 | 01-NOV-00:10 | 0.74 |
| December | 0.124124E+09 | 0.75 | 46.34 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.146145E+10 | 0.74 | |||
| Minimum of Months | 0.112112E+09 | 0.74 | 46.34 | 0.74 | |
| Maximum of Months | 0.124124E+09 | 0.75 | 46.34 | 0.75 |
Report: FanReportMonthly
For: SPLIT TSW SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 29169870.54 | 0.31 | 503.13 | 03-JAN-14:22 | 0.94 |
| February | 64179745.78 | 0.30 | 503.13 | 01-FEB-14:52 | 0.94 |
| March | 0.198503E+09 | 0.65 | 503.13 | 01-MAR-11:52 | 0.94 |
| April | 0.356684E+09 | 0.96 | 503.13 | 01-APR-07:52 | 0.93 |
| May | 0.466719E+09 | 1.04 | 503.13 | 13-MAY-07:52 | 0.93 |
| June | 0.475933E+09 | 1.03 | 503.13 | 18-JUN-06:52 | 0.93 |
| July | 0.472460E+09 | 1.04 | 346.97 | 02-JUL-16:30 | 0.98 |
| August | 0.432847E+09 | 1.04 | 305.95 | 06-AUG-16:13 | 1.00 |
| September | 0.376182E+09 | 1.04 | 503.13 | 27-SEP-07:12 | 0.93 |
| October | 0.286173E+09 | 0.83 | 503.13 | 01-OCT-07:52 | 0.93 |
| November | 0.143667E+09 | 0.44 | 503.13 | 01-NOV-10:02 | 0.94 |
| December | 36365917.04 | 0.25 | 503.13 | 01-DEC-11:02 | 0.94 |
| Annual Sum or Average | 0.333888E+10 | 0.75 | |||
| Minimum of Months | 29169870.54 | 0.25 | 305.95 | 0.93 | |
| Maximum of Months | 0.475933E+09 | 1.04 | 503.13 | 1.00 |
Report: FanReportMonthly
For: T SW APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.74 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.73 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.73 | 23.17 | 01-AUG-00:10 | 0.73 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.73 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.75 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.73 | 23.17 | 0.73 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: T SW APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.74 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.74 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.74 | 23.17 | 01-AUG-00:10 | 0.74 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.74 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.74 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.74 | 23.17 | 0.74 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: SPLIT TNW SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 29000578.59 | 0.37 | 267.46 | 14-JAN-22:52 | 1.01 |
| February | 26127490.62 | 0.23 | 504.66 | 08-FEB-13:42 | 0.93 |
| March | 0.144895E+09 | 0.60 | 504.66 | 01-MAR-14:22 | 0.94 |
| April | 0.320033E+09 | 0.96 | 504.66 | 01-APR-07:52 | 0.93 |
| May | 0.460624E+09 | 1.04 | 504.66 | 13-MAY-07:52 | 0.93 |
| June | 0.478836E+09 | 1.03 | 504.66 | 18-JUN-06:52 | 0.93 |
| July | 0.473652E+09 | 1.04 | 342.26 | 02-JUL-16:50 | 0.99 |
| August | 0.426905E+09 | 1.04 | 297.97 | 07-AUG-16:20 | 1.00 |
| September | 0.345275E+09 | 1.05 | 504.66 | 27-SEP-07:12 | 0.93 |
| October | 0.210043E+09 | 0.79 | 504.66 | 01-OCT-08:22 | 0.93 |
| November | 63482781.37 | 0.31 | 504.66 | 01-NOV-11:02 | 0.94 |
| December | 14636216.52 | 0.26 | 504.66 | 01-DEC-15:41 | 0.94 |
| Annual Sum or Average | 0.299351E+10 | 0.73 | |||
| Minimum of Months | 14636216.52 | 0.23 | 267.46 | 0.93 | |
| Maximum of Months | 0.478836E+09 | 1.05 | 504.66 | 1.01 |
Report: FanReportMonthly
For: T NW APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.74 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.73 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.73 | 23.17 | 01-AUG-00:10 | 0.73 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.73 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.74 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.73 | 23.17 | 0.73 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: T NW APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.74 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.74 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.74 | 23.17 | 01-AUG-00:10 | 0.74 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.74 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.74 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.74 | 23.17 | 0.74 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: SPLIT TSE SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 26585892.98 | 0.29 | 476.86 | 03-JAN-14:22 | 0.94 |
| February | 63326909.47 | 0.30 | 476.86 | 01-FEB-13:12 | 0.94 |
| March | 0.196668E+09 | 0.65 | 476.86 | 01-MAR-11:52 | 0.94 |
| April | 0.355559E+09 | 0.97 | 476.86 | 01-APR-07:52 | 0.93 |
| May | 0.465617E+09 | 1.03 | 476.86 | 13-MAY-07:52 | 0.93 |
| June | 0.467820E+09 | 1.03 | 476.86 | 18-JUN-06:52 | 0.93 |
| July | 0.469147E+09 | 1.03 | 301.08 | 02-JUL-16:10 | 0.99 |
| August | 0.430067E+09 | 1.04 | 278.07 | 07-AUG-15:10 | 1.00 |
| September | 0.372427E+09 | 1.04 | 476.86 | 27-SEP-07:12 | 0.93 |
| October | 0.285619E+09 | 0.83 | 476.86 | 01-OCT-07:52 | 0.93 |
| November | 0.141499E+09 | 0.44 | 476.86 | 01-NOV-10:02 | 0.94 |
| December | 34278331.41 | 0.24 | 476.86 | 01-DEC-11:02 | 0.94 |
| Annual Sum or Average | 0.330861E+10 | 0.74 | |||
| Minimum of Months | 26585892.98 | 0.24 | 278.07 | 0.93 | |
| Maximum of Months | 0.469147E+09 | 1.04 | 476.86 | 1.00 |
Report: FanReportMonthly
For: T SE APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.74 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.73 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.73 | 23.17 | 01-AUG-00:10 | 0.73 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.73 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.75 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.73 | 23.17 | 0.73 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: T SE APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.74 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.74 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.74 | 23.17 | 01-AUG-00:10 | 0.74 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.74 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.74 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.74 | 23.17 | 0.74 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: SPLIT TNE SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 27137154.69 | 0.34 | 169.99 | 26-JAN-20:42 | 1.04 |
| February | 24685188.41 | 0.22 | 478.37 | 07-FEB-13:22 | 0.94 |
| March | 0.142627E+09 | 0.60 | 478.37 | 01-MAR-14:22 | 0.94 |
| April | 0.319362E+09 | 0.97 | 478.37 | 01-APR-07:52 | 0.93 |
| May | 0.459831E+09 | 1.03 | 478.37 | 13-MAY-07:52 | 0.93 |
| June | 0.470917E+09 | 1.03 | 478.37 | 18-JUN-06:52 | 0.93 |
| July | 0.470569E+09 | 1.03 | 294.94 | 02-JUL-17:10 | 1.00 |
| August | 0.424415E+09 | 1.04 | 270.37 | 07-AUG-16:10 | 1.00 |
| September | 0.342050E+09 | 1.04 | 478.37 | 27-SEP-07:12 | 0.93 |
| October | 0.209781E+09 | 0.80 | 478.37 | 01-OCT-08:22 | 0.93 |
| November | 60889200.77 | 0.31 | 478.37 | 01-NOV-11:02 | 0.94 |
| December | 13768675.97 | 0.24 | 478.37 | 01-DEC-15:41 | 0.94 |
| Annual Sum or Average | 0.296603E+10 | 0.72 | |||
| Minimum of Months | 13768675.97 | 0.22 | 169.99 | 0.93 | |
| Maximum of Months | 0.470917E+09 | 1.04 | 478.37 | 1.04 |
Report: FanReportMonthly
For: T NE APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.74 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.73 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.73 | 23.17 | 01-AUG-00:10 | 0.73 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.73 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.74 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.73 | 23.17 | 0.73 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: T NE APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.74 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.74 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.74 | 23.17 | 01-AUG-00:10 | 0.74 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.74 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.74 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.74 | 23.17 | 0.74 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: SPLIT TN1 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 12952413.47 | 0.28 | 372.35 | 14-JAN-22:52 | 0.95 |
| February | 19821542.51 | 0.22 | 426.17 | 08-FEB-13:42 | 0.93 |
| March | 0.118712E+09 | 0.64 | 426.17 | 01-MAR-14:22 | 0.94 |
| April | 0.252407E+09 | 0.97 | 426.17 | 01-APR-07:52 | 0.93 |
| May | 0.367121E+09 | 1.04 | 426.17 | 13-MAY-07:52 | 0.93 |
| June | 0.386708E+09 | 1.03 | 426.17 | 18-JUN-06:52 | 0.93 |
| July | 0.394396E+09 | 1.04 | 243.40 | 02-JUL-17:20 | 1.00 |
| August | 0.360694E+09 | 1.04 | 219.47 | 07-AUG-16:20 | 1.01 |
| September | 0.291340E+09 | 1.05 | 426.17 | 27-SEP-07:12 | 0.93 |
| October | 0.175212E+09 | 0.81 | 426.17 | 01-OCT-08:22 | 0.93 |
| November | 52039760.93 | 0.37 | 426.17 | 01-NOV-11:02 | 0.94 |
| December | 5343974.07 | 0.11 | 426.17 | 01-DEC-15:41 | 0.94 |
| Annual Sum or Average | 0.243675E+10 | 0.72 | |||
| Minimum of Months | 5343974.07 | 0.11 | 219.47 | 0.93 | |
| Maximum of Months | 0.394396E+09 | 1.05 | 426.17 | 1.01 |
Report: FanReportMonthly
For: T N1 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.74 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.73 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.73 | 23.17 | 01-AUG-00:10 | 0.73 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.73 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.74 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.73 | 23.17 | 0.73 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: T N1 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.74 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.74 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.74 | 23.17 | 01-AUG-00:10 | 0.74 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.74 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.74 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.74 | 23.17 | 0.74 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: SPLIT TN2 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 12998453.11 | 0.28 | 362.80 | 14-JAN-22:52 | 0.96 |
| February | 20033404.39 | 0.22 | 425.30 | 08-FEB-13:42 | 0.93 |
| March | 0.119140E+09 | 0.65 | 425.30 | 01-MAR-14:22 | 0.94 |
| April | 0.252553E+09 | 0.97 | 425.30 | 01-APR-07:52 | 0.93 |
| May | 0.367162E+09 | 1.04 | 425.30 | 13-MAY-07:52 | 0.93 |
| June | 0.386479E+09 | 1.03 | 425.30 | 18-JUN-06:52 | 0.93 |
| July | 0.394318E+09 | 1.04 | 242.28 | 02-JUL-17:20 | 1.00 |
| August | 0.360634E+09 | 1.04 | 218.92 | 07-AUG-16:20 | 1.01 |
| September | 0.291256E+09 | 1.05 | 425.30 | 27-SEP-07:12 | 0.93 |
| October | 0.175427E+09 | 0.81 | 425.30 | 01-OCT-08:22 | 0.93 |
| November | 52264131.29 | 0.37 | 425.30 | 01-NOV-11:02 | 0.94 |
| December | 5348951.75 | 0.11 | 425.30 | 01-DEC-15:41 | 0.94 |
| Annual Sum or Average | 0.243761E+10 | 0.72 | |||
| Minimum of Months | 5348951.75 | 0.11 | 218.92 | 0.93 | |
| Maximum of Months | 0.394318E+09 | 1.05 | 425.30 | 1.01 |
Report: FanReportMonthly
For: T N2 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.74 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.73 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.73 | 23.17 | 01-AUG-00:10 | 0.73 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.73 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.74 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.73 | 23.17 | 0.73 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: T N2 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.74 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.74 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.74 | 23.17 | 01-AUG-00:10 | 0.74 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.74 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.74 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.74 | 23.17 | 0.74 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: SPLIT TS1 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 21154325.49 | 0.22 | 424.89 | 03-JAN-14:22 | 0.94 |
| February | 61829340.55 | 0.35 | 424.89 | 01-FEB-13:12 | 0.94 |
| March | 0.173034E+09 | 0.71 | 424.89 | 01-MAR-11:52 | 0.94 |
| April | 0.288938E+09 | 0.97 | 424.89 | 01-APR-07:52 | 0.93 |
| May | 0.372889E+09 | 1.04 | 424.89 | 13-MAY-07:52 | 0.93 |
| June | 0.383310E+09 | 1.03 | 424.89 | 18-JUN-06:52 | 0.93 |
| July | 0.392697E+09 | 1.04 | 247.20 | 02-JUL-16:20 | 1.00 |
| August | 0.366202E+09 | 1.04 | 229.79 | 27-AUG-16:02 | 1.01 |
| September | 0.322084E+09 | 1.04 | 424.89 | 27-SEP-07:12 | 0.93 |
| October | 0.251416E+09 | 0.84 | 424.89 | 01-OCT-07:52 | 0.93 |
| November | 0.134975E+09 | 0.54 | 424.89 | 01-NOV-10:02 | 0.94 |
| December | 36517819.92 | 0.26 | 424.89 | 01-DEC-11:02 | 0.94 |
| Annual Sum or Average | 0.280505E+10 | 0.76 | |||
| Minimum of Months | 21154325.49 | 0.22 | 229.79 | 0.93 | |
| Maximum of Months | 0.392697E+09 | 1.04 | 424.89 | 1.01 |
Report: FanReportMonthly
For: T S1 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.75 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.73 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.73 | 23.17 | 01-AUG-00:10 | 0.73 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.73 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.75 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.73 | 23.17 | 0.73 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: T S1 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.74 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.74 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.74 | 23.17 | 01-AUG-00:10 | 0.74 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.74 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.75 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.74 | 23.17 | 0.74 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: SPLIT TS2 SUPPLY FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 21277142.94 | 0.22 | 424.02 | 03-JAN-14:22 | 0.94 |
| February | 62155355.78 | 0.35 | 424.02 | 01-FEB-13:12 | 0.94 |
| March | 0.173375E+09 | 0.71 | 424.02 | 01-MAR-11:52 | 0.94 |
| April | 0.289044E+09 | 0.97 | 424.02 | 01-APR-07:52 | 0.93 |
| May | 0.372918E+09 | 1.04 | 424.02 | 13-MAY-07:52 | 0.93 |
| June | 0.383075E+09 | 1.03 | 424.02 | 18-JUN-06:52 | 0.93 |
| July | 0.392610E+09 | 1.04 | 246.33 | 02-JUL-16:20 | 1.00 |
| August | 0.366132E+09 | 1.04 | 229.45 | 27-AUG-16:02 | 1.01 |
| September | 0.321978E+09 | 1.04 | 424.02 | 27-SEP-07:12 | 0.93 |
| October | 0.251546E+09 | 0.84 | 424.02 | 01-OCT-07:52 | 0.93 |
| November | 0.135163E+09 | 0.54 | 424.02 | 01-NOV-10:02 | 0.94 |
| December | 36648079.28 | 0.26 | 424.02 | 01-DEC-11:02 | 0.94 |
| Annual Sum or Average | 0.280592E+10 | 0.76 | |||
| Minimum of Months | 21277142.94 | 0.22 | 229.45 | 0.93 | |
| Maximum of Months | 0.392610E+09 | 1.04 | 424.02 | 1.01 |
Report: FanReportMonthly
For: T S2 APARTMENT ERV SUP FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.75 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.73 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.73 | 23.17 | 01-AUG-00:10 | 0.73 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.73 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.75 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.73 | 23.17 | 0.73 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: FanReportMonthly
For: T S2 APARTMENT ERV EXH FAN
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| FAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
| January | 62061755.14 | 0.75 | 23.17 | 01-JAN-00:10 | 0.75 |
| February | 56055778.84 | 0.75 | 23.17 | 01-FEB-00:10 | 0.75 |
| March | 62061755.14 | 0.74 | 23.17 | 01-MAR-00:10 | 0.74 |
| April | 60059763.04 | 0.74 | 23.17 | 01-APR-00:10 | 0.74 |
| May | 62061755.14 | 0.74 | 23.17 | 01-MAY-00:10 | 0.75 |
| June | 60059763.04 | 0.74 | 23.17 | 01-JUN-00:10 | 0.74 |
| July | 62061755.14 | 0.74 | 23.17 | 01-JUL-00:10 | 0.74 |
| August | 62061755.14 | 0.74 | 23.17 | 01-AUG-00:10 | 0.74 |
| September | 60059763.04 | 0.74 | 23.17 | 01-SEP-00:10 | 0.74 |
| October | 62061755.14 | 0.74 | 23.17 | 01-OCT-00:10 | 0.74 |
| November | 60059763.04 | 0.75 | 23.17 | 01-NOV-00:10 | 0.74 |
| December | 62061755.14 | 0.75 | 23.17 | 01-DEC-00:10 | 0.75 |
| Annual Sum or Average | 0.730727E+09 | 0.74 | |||
| Minimum of Months | 56055778.84 | 0.74 | 23.17 | 0.74 | |
| Maximum of Months | 62061755.14 | 0.75 | 23.17 | 0.75 |
Report: PumpReportMonthly
For: SWHSYS1 PUMP
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
| January | 38818862.27 | 11645658.68 | 14.49 | 01-JAN-00:10 | 4.35 | 4.35 | 56.04 | 0.11 |
| February | 35062198.18 | 10518659.46 | 14.49 | 01-FEB-00:10 | 4.35 | 4.35 | 56.03 | 0.11 |
| March | 38818862.27 | 11645658.68 | 14.49 | 01-MAR-00:10 | 4.35 | 4.35 | 56.20 | 0.11 |
| April | 37566640.91 | 11269992.27 | 14.49 | 01-APR-00:10 | 4.35 | 4.35 | 58.47 | 0.11 |
| May | 38818862.27 | 11645658.68 | 14.49 | 01-MAY-00:10 | 4.35 | 4.35 | 58.62 | 0.11 |
| June | 37566640.91 | 11269992.27 | 14.49 | 01-JUN-00:10 | 4.35 | 4.35 | 58.78 | 0.11 |
| July | 38818862.27 | 11645658.68 | 14.49 | 01-JUL-00:10 | 4.35 | 4.35 | 58.87 | 0.11 |
| August | 38818862.27 | 11645658.68 | 14.49 | 01-AUG-00:10 | 4.35 | 4.35 | 58.87 | 0.11 |
| September | 37566640.91 | 11269992.27 | 14.49 | 01-SEP-00:10 | 4.35 | 4.35 | 58.80 | 0.11 |
| October | 38818862.27 | 11645658.68 | 14.49 | 01-OCT-00:10 | 4.35 | 4.35 | 58.65 | 0.11 |
| November | 37566640.91 | 11269992.27 | 14.49 | 01-NOV-00:10 | 4.35 | 4.35 | 58.48 | 0.11 |
| December | 38818862.27 | 11645658.68 | 14.49 | 01-DEC-00:10 | 4.35 | 4.35 | 56.24 | 0.11 |
| Annual Sum or Average | 0.457061E+09 | 0.137118E+09 | ||||||
| Minimum of Months | 35062198.18 | 10518659.46 | 14.49 | 4.35 | 4.35 | 56.03 | 0.11 | |
| Maximum of Months | 38818862.27 | 11645658.68 | 14.49 | 4.35 | 4.35 | 58.87 | 0.11 |
Report: CondLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| PLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
| January | 0.00 | 0.00 | 01-JAN-00:10 | 56.04 | 59.95 | 9722.12 | 18573.17 | 17-JAN-07:40 |
| February | 0.00 | 0.00 | 01-FEB-00:10 | 56.03 | 59.95 | 9517.46 | 18461.71 | 01-FEB-07:40 |
| March | 0.00 | 0.00 | 01-MAR-00:10 | 56.20 | 59.95 | 8903.40 | 17670.54 | 01-MAR-07:50 |
| April | 0.00 | 0.00 | 01-APR-00:10 | 58.47 | 59.95 | 8013.67 | 16121.10 | 01-APR-06:50 |
| May | 0.00 | 0.00 | 01-MAY-00:10 | 58.62 | 59.94 | 7098.17 | 14347.62 | 01-MAY-06:50 |
| June | 0.00 | 0.00 | 01-JUN-00:10 | 58.78 | 59.95 | 6402.41 | 12719.92 | 01-JUN-06:50 |
| July | 0.00 | 0.00 | 01-JUL-00:10 | 58.87 | 59.95 | 6116.84 | 11767.65 | 01-JUL-06:50 |
| August | 0.00 | 0.00 | 01-AUG-00:10 | 58.87 | 59.94 | 6322.37 | 12522.05 | 31-AUG-06:40 |
| September | 0.00 | 0.00 | 01-SEP-00:10 | 58.80 | 59.96 | 6957.63 | 14019.11 | 30-SEP-06:50 |
| October | 0.00 | 0.00 | 01-OCT-00:10 | 58.65 | 59.95 | 7852.83 | 15850.65 | 31-OCT-06:50 |
| November | 0.00 | 0.00 | 01-NOV-00:10 | 58.48 | 59.94 | 8765.38 | 17429.35 | 30-NOV-07:50 |
| December | 0.00 | 0.00 | 01-DEC-00:10 | 56.24 | 59.95 | 9449.24 | 18417.70 | 31-DEC-07:40 |
| Annual Sum or Average | 0.00 | 7918.02 | ||||||
| Minimum of Months | 0.00 | 0.00 | 56.03 | 59.94 | 6116.84 | 11767.65 | ||
| Maximum of Months | 0.00 | 0.00 | 58.87 | 59.96 | 9722.12 | 18573.17 |
Report: ZoneTemperatureOscillationReportMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: T CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: G CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: M CORRIDOR
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
| January | 0.00 | 0.00 |
| February | 0.00 | 0.00 |
| March | 0.00 | 0.00 |
| April | 0.00 | 0.00 |
| May | 0.00 | 0.00 |
| June | 0.00 | 0.00 |
| July | 0.00 | 0.00 |
| August | 0.00 | 0.00 |
| September | 0.00 | 0.00 |
| October | 0.00 | 0.00 |
| November | 0.00 | 0.00 |
| December | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | |
| Minimum of Months | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.138234E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.278214E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.723666E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.131981E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.185991E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.203951E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.218942E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.210959E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.189353E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.145928E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.837219E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.329724E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.151781E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.138234E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.218942E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 6568783.66 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 84305238.64 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.491074E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.115889E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.182993E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.205262E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.219419E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.208527E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.176300E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.113800E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.470318E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 60477922.03 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.133346E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 6568783.66 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.219419E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.140616E+10 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.138443E+10 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.177368E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.203636E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.255365E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.263669E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.269608E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.268711E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.237356E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.217906E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.176544E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.151674E+10 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.250090E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.138443E+10 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.269608E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 6076649.80 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 85595750.80 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.489188E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.116259E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.183506E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.202730E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.218943E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.208091E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.175324E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.114046E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.466548E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 58812022.78 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.132952E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 6076649.80 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.218943E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 25795611.03 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.111104E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.459760E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.963280E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.150102E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.168746E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.183946E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.175638E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.148055E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.960194E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.440698E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.117985E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.113437E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 25795611.03 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.183946E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 25900257.90 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.112182E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.460838E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.963478E+09 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.150073E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.168602E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.183871E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.175569E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.147968E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.960267E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.441208E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.118072E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.113428E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 25900257.90 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.183871E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.240075E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.349285E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.701902E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.113038E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.153534E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.167706E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.183777E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.178437E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.161722E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.128762E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.814557E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.427584E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.134032E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.240075E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.183777E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT GS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.235954E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.358929E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.742480E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.121925E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.165157E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.178986E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.196064E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.189847E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.172574E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.137161E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.859085E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.434245E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.142478E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.235954E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.196064E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.382434E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.810408E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.192273E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.314347E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.406424E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.417367E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.419670E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.386247E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.341892E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.268591E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.156510E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.617804E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.308439E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.382434E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.419670E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 30368725.60 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.332577E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.142637E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.280048E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.399524E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.419239E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.419645E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.379935E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.312601E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.199408E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.783978E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 84327791.33 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.267616E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 30368725.60 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.419645E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MSE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.393406E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.825540E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.192431E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.314839E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.407414E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.411876E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.418821E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.385537E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.339911E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.269255E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.155787E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.622717E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.308004E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.393406E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.418821E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 29507903.16 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.338373E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.142424E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.280687E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.400537E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.413726E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.418788E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.379255E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.310766E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.200122E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.767123E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 77137308.76 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.266752E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 29507903.16 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.418788E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.106335E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.400374E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.122295E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.218470E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.312242E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.332972E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.346420E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.319260E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.263122E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.169011E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.766516E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.208806E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.223199E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.106335E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.346420E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.106950E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.403213E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.122657E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.218617E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.312327E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.332844E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.346423E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.319269E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.263090E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.169189E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.768146E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.209291E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.223318E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.106950E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.346423E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.635318E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.922488E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.172407E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.253051E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.319202E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.330939E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.346306E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.325560E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.292781E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.238832E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.156541E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.868098E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.267821E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.635318E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.346306E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT MS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.636210E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.924891E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.172687E+10 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.253179E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.319286E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.330811E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.346309E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.325568E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.292744E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.238955E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.156694E+10 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.869163E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.267926E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.636210E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.346309E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.138338E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.294111E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.928923E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.172238E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.230737E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.237593E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.234644E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.212578E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.182572E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.136124E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.666614E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.167174E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.162600E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.138338E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.237593E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.147300E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.121686E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.677620E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.154172E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.227108E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.238438E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.234605E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.209141E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.167183E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.997765E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.295099E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 74116397.30 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.146201E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 74116397.30 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.238438E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TSE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.126625E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.291271E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.923504E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.172187E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.230907E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.234328E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.233807E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.211925E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.181334E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.136296E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.658887E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.158152E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.161663E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.126625E+09 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.234328E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 0.137875E+09 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.115256E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.669244E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.154221E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.227331E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.235188E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.233794E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.208539E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.166086E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.999446E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.284139E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 69938241.93 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.145275E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 69938241.93 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.235188E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 66005614.60 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 91880045.49 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.559788E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.122644E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.182805E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.194662E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.197487E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.178567E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.142438E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.839130E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.244072E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 26687962.17 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.120136E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 26687962.17 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.197487E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 66248498.76 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 92872733.41 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.561882E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.122730E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.182849E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.194572E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.197474E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.178561E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.142416E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.840285E+09 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.245171E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 26717555.39 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.120192E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 26717555.39 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.197474E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 97783799.94 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.285703E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.817709E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.140962E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.186466E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.193734E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.197462E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.182013E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.158080E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.120785E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.632642E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.167833E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.137967E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 97783799.94 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.197462E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: SPLIT TS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
| January | 0.00 | 0.00 | 0.00 | 98368594.05 | 0.00 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.287258E+09 | 0.00 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.819437E+09 | 0.00 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.141034E+10 | 0.00 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.186508E+10 | 0.00 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.193644E+10 | 0.00 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.197448E+10 | 0.00 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.182006E+10 | 0.00 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.158052E+10 | 0.00 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.120866E+10 | 0.00 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.633627E+09 | 0.00 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.168455E+09 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.138027E+11 | 0.00 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 98368594.05 | 0.00 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.197448E+10 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 29999556.23 | 0.426025E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 60027037.34 | 0.856535E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.152754E+09 | 0.213660E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.270095E+09 | 0.367283E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.371156E+09 | 0.505306E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.402786E+09 | 0.558893E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.435069E+09 | 0.627964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.424514E+09 | 0.620726E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.386220E+09 | 0.561826E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.304517E+09 | 0.433712E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.178789E+09 | 0.254301E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 71525132.78 | 0.100970E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.308745E+10 | 0.437290E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 29999556.23 | 0.426025E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.435069E+09 | 0.627964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 1408500.34 | 17459077.06 | 2041751.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 18222145.13 | 0.254345E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.103893E+09 | 0.143289E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.238206E+09 | 0.320658E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.367031E+09 | 0.496689E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.407423E+09 | 0.562333E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.438287E+09 | 0.628929E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.421710E+09 | 0.613007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.361325E+09 | 0.521970E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.238460E+09 | 0.335170E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.100726E+09 | 0.140184E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 13175828.76 | 0.181894E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.270987E+10 | 0.380760E+11 | 2041751.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 1408500.34 | 17459077.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.438287E+09 | 0.628929E+10 | 2041751.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.122128E+10 | 0.708189E+09 | 124166.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.110558E+10 | 0.108234E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.122777E+10 | 0.207972E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.120437E+10 | 0.299701E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.125113E+10 | 0.456201E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.121227E+10 | 0.507555E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.125651E+10 | 0.544952E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.125387E+10 | 0.558525E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.121395E+10 | 0.453891E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.124920E+10 | 0.358125E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.119957E+10 | 0.221098E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.122750E+10 | 0.112040E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.146230E+11 | 0.389911E+11 | 124166.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.110558E+10 | 0.708189E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.125651E+10 | 0.558525E+10 | 124166.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 1299753.31 | 16231167.80 | 1797757.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 18443714.14 | 0.258471E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.103183E+09 | 0.143054E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.238404E+09 | 0.322717E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.367132E+09 | 0.499607E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.401296E+09 | 0.556855E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.436121E+09 | 0.629337E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.419686E+09 | 0.613434E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.358364E+09 | 0.520392E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.238324E+09 | 0.336746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 99626368.86 | 0.139297E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 12774255.54 | 0.176924E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.269465E+10 | 0.380660E+11 | 1797757.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 1299753.31 | 16231167.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.436121E+09 | 0.629337E+10 | 1797757.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 5523070.15 | 78333552.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 23726619.85 | 0.336879E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 96245285.04 | 0.135437E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.195646E+09 | 0.268524E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.296947E+09 | 0.410052E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.329976E+09 | 0.465454E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.361813E+09 | 0.531082E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.349848E+09 | 0.520433E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.299090E+09 | 0.441986E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.198645E+09 | 0.284928E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 93275425.52 | 0.132453E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 25356784.65 | 0.354337E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.227609E+10 | 0.326730E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 5523070.15 | 78333552.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.361813E+09 | 0.531082E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 5545185.00 | 78645491.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 23954834.71 | 0.340188E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 96459307.29 | 0.135778E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.195653E+09 | 0.268615E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.296834E+09 | 0.410022E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.329631E+09 | 0.465109E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.361612E+09 | 0.530939E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.349666E+09 | 0.520305E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.298876E+09 | 0.441787E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.198632E+09 | 0.284991E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 93371981.88 | 0.132625E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 25373339.50 | 0.354622E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.227561E+10 | 0.326751E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 5545185.00 | 78645491.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.361612E+09 | 0.530939E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 51181295.79 | 0.736954E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 74098989.51 | 0.108080E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.145873E+09 | 0.209654E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.227561E+09 | 0.317239E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.300876E+09 | 0.420103E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.324860E+09 | 0.463058E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.358037E+09 | 0.531311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.352131E+09 | 0.529550E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.323736E+09 | 0.483983E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.264098E+09 | 0.386045E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.171069E+09 | 0.249973E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 91157243.45 | 0.131557E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.268468E+10 | 0.390425E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 51181295.79 | 0.736954E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.358037E+09 | 0.531311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT GS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 50341504.01 | 0.724191E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 76204852.86 | 0.111045E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.154486E+09 | 0.222058E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.245885E+09 | 0.343368E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.324303E+09 | 0.453378E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.347463E+09 | 0.495472E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.382820E+09 | 0.567842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.375429E+09 | 0.564221E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.346142E+09 | 0.517382E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.281768E+09 | 0.412262E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.180617E+09 | 0.263972E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 92651440.35 | 0.133567E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.285811E+10 | 0.415699E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 50341504.01 | 0.724191E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.382820E+09 | 0.567842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 83649700.62 | 0.116973E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.176285E+09 | 0.248701E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.409709E+09 | 0.569630E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.648822E+09 | 0.875828E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.817461E+09 | 0.110020E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.830117E+09 | 0.113561E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.838497E+09 | 0.119320E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.780840E+09 | 0.112559E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.700458E+09 | 0.100367E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.563204E+09 | 0.788937E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.336250E+09 | 0.472147E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.135044E+09 | 0.189251E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.632034E+10 | 0.881974E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 83649700.62 | 0.116973E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.838497E+09 | 0.119320E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 6633325.19 | 91109599.81 | 324487.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 72473816.49 | 0.100256E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.304732E+09 | 0.418230E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.580179E+09 | 0.776186E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.806823E+09 | 0.108062E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.837112E+09 | 0.114037E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.841845E+09 | 0.119238E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.771008E+09 | 0.110639E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.642762E+09 | 0.916521E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.419419E+09 | 0.580726E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.168634E+09 | 0.231796E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 18480835.58 | 0.254129E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.547010E+10 | 0.757799E+11 | 324487.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 6633325.19 | 91109599.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.841845E+09 | 0.119238E+11 | 324487.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MSE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 85751157.02 | 0.120274E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.178934E+09 | 0.253951E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.408655E+09 | 0.571971E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.647913E+09 | 0.880485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.816925E+09 | 0.110670E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.816493E+09 | 0.112395E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.833964E+09 | 0.119422E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.776823E+09 | 0.112668E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.694142E+09 | 0.100060E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.562768E+09 | 0.793581E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.333542E+09 | 0.471426E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.135637E+09 | 0.191027E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.629155E+10 | 0.883487E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 85751157.02 | 0.120274E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.833964E+09 | 0.119422E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 6420956.72 | 87884006.41 | 827615.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 73513930.77 | 0.102103E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.303382E+09 | 0.418526E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.580166E+09 | 0.780689E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.806875E+09 | 0.108704E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.823892E+09 | 0.112861E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.837814E+09 | 0.119330E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.767576E+09 | 0.110741E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.637345E+09 | 0.913444E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.419782E+09 | 0.584485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.164491E+09 | 0.227212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 16853989.90 | 0.232489E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.543811E+10 | 0.757486E+11 | 827615.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 6420956.72 | 87884006.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.837814E+09 | 0.119330E+11 | 827615.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 22942566.82 | 0.320754E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 86167114.82 | 0.121256E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.258220E+09 | 0.361489E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.446943E+09 | 0.608791E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.621601E+09 | 0.849263E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.654674E+09 | 0.912144E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.684258E+09 | 0.992412E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.638267E+09 | 0.938422E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.533502E+09 | 0.779249E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.351161E+09 | 0.496999E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.163064E+09 | 0.228595E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 45140998.13 | 0.626770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.450594E+10 | 0.638337E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 22942566.82 | 0.320754E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.684258E+09 | 0.992412E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 23074559.29 | 0.322587E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 86773242.68 | 0.122126E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.258967E+09 | 0.362602E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.447214E+09 | 0.609235E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.621728E+09 | 0.849520E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.654378E+09 | 0.911820E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.684221E+09 | 0.992465E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.638246E+09 | 0.938491E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.533401E+09 | 0.779180E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.351506E+09 | 0.497544E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.163396E+09 | 0.229093E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 45243505.75 | 0.628227E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.450815E+10 | 0.638716E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 23074559.29 | 0.322587E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.684221E+09 | 0.992465E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.136526E+09 | 0.194297E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.197318E+09 | 0.284956E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.361532E+09 | 0.515628E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.513684E+09 | 0.709253E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.630433E+09 | 0.869161E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.645595E+09 | 0.907309E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.678579E+09 | 0.993222E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.645834E+09 | 0.958009E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.589130E+09 | 0.867976E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.492623E+09 | 0.708721E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.330985E+09 | 0.477502E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.186511E+09 | 0.266735E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.540875E+10 | 0.775277E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.136526E+09 | 0.194297E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.678579E+09 | 0.993222E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT MS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 0.136706E+09 | 0.194581E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.197815E+09 | 0.285732E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.362089E+09 | 0.516525E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.513901E+09 | 0.709664E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.630545E+09 | 0.869421E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.645291E+09 | 0.906987E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.678530E+09 | 0.993277E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.645799E+09 | 0.958080E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.589008E+09 | 0.867906E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.492837E+09 | 0.709141E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.331278E+09 | 0.478016E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.186725E+09 | 0.267080E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.541053E+10 | 0.775641E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.136706E+09 | 0.194581E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.678530E+09 | 0.993277E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 29169870.54 | 0.253013E+09 | 0.150191E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 64179745.78 | 0.888451E+09 | 20525536.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.198503E+09 | 0.273736E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.356684E+09 | 0.476978E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.466719E+09 | 0.621711E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.475933E+09 | 0.643787E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.472460E+09 | 0.664511E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.432847E+09 | 0.616608E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.376182E+09 | 0.533003E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.286173E+09 | 0.396747E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.143667E+09 | 0.200665E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 36365917.04 | 0.462447E+09 | 51765566.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.333888E+10 | 0.458814E+11 | 0.222482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 29169870.54 | 0.253013E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.475933E+09 | 0.664511E+10 | 0.150191E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 29000578.59 | 1391951.23 | 0.382847E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 26127490.62 | 0.305120E+09 | 54211287.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.144895E+09 | 0.197072E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.320033E+09 | 0.424257E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.460624E+09 | 0.611249E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.478836E+09 | 0.645844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.473652E+09 | 0.663962E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.426905E+09 | 0.606087E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.345275E+09 | 0.487058E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.210043E+09 | 0.287584E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 63482781.37 | 0.862548E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 14636216.52 | 17877904.28 | 0.179921E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.299351E+10 | 0.404181E+11 | 0.616979E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 14636216.52 | 1391951.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.478836E+09 | 0.663962E+10 | 0.382847E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TSE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 26585892.98 | 0.228275E+09 | 0.140802E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 63326909.47 | 0.885312E+09 | 18718344.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.196668E+09 | 0.273399E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.355559E+09 | 0.479084E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.465617E+09 | 0.624985E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.467820E+09 | 0.637407E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.469147E+09 | 0.664691E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.430067E+09 | 0.616989E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.372427E+09 | 0.531288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.285619E+09 | 0.399050E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.141499E+09 | 0.199215E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 34278331.41 | 0.438957E+09 | 49294285.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.330861E+10 | 0.458136E+11 | 0.208815E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 26585892.98 | 0.228275E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.469147E+09 | 0.664691E+10 | 0.140802E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 27137154.69 | 735938.90 | 0.357233E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 24685188.41 | 0.292149E+09 | 48604686.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.142627E+09 | 0.195161E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.319362E+09 | 0.426229E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.459831E+09 | 0.614571E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.470917E+09 | 0.639488E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.470569E+09 | 0.664167E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.424415E+09 | 0.606503E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.342050E+09 | 0.485432E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.209781E+09 | 0.289069E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 60889200.77 | 0.831706E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 13768675.97 | 14023356.61 | 0.171862E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.296603E+10 | 0.403448E+11 | 0.577700E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 13768675.97 | 735938.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.470917E+09 | 0.664167E+10 | 0.357233E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 12952413.47 | 3910659.51 | 0.167016E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 19821542.51 | 0.266793E+09 | 10025962.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.118712E+09 | 0.163465E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.252407E+09 | 0.338201E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.367121E+09 | 0.493287E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.386708E+09 | 0.529341E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.394396E+09 | 0.561841E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.360694E+09 | 0.520824E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.291340E+09 | 0.417956E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.175212E+09 | 0.243479E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 52039760.93 | 0.717289E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 5343974.07 | 15953380.54 | 55417981.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.243675E+10 | 0.336879E+11 | 0.232460E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 5343974.07 | 3910659.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.394396E+09 | 0.561841E+10 | 0.167016E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 12998453.11 | 3797198.25 | 0.167724E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 20033404.39 | 0.269835E+09 | 10027375.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.119140E+09 | 0.164113E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.252553E+09 | 0.338490E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.367162E+09 | 0.493465E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.386479E+09 | 0.529159E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.394318E+09 | 0.561874E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.360634E+09 | 0.520869E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.291256E+09 | 0.417933E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.175427E+09 | 0.243841E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 52264131.29 | 0.720588E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 5348951.75 | 15917460.34 | 55527553.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.243761E+10 | 0.337076E+11 | 0.233279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 5348951.75 | 3797198.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.394318E+09 | 0.561874E+10 | 0.167724E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 21154325.49 | 0.284671E+09 | 19536920.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 61829340.55 | 0.888220E+09 | 2409218.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.173034E+09 | 0.242272E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.288938E+09 | 0.391341E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.372889E+09 | 0.503748E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.383310E+09 | 0.527125E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.392697E+09 | 0.562287E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.366202E+09 | 0.531436E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.322084E+09 | 0.464622E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.251416E+09 | 0.354476E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.134975E+09 | 0.191944E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 36517819.92 | 0.522537E+09 | 4789334.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.280505E+10 | 0.393879E+11 | 26735473.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 21154325.49 | 0.284671E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.392697E+09 | 0.562287E+10 | 19536920.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: SPLIT TS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
| January | 21277142.94 | 0.286517E+09 | 19630634.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 62155355.78 | 0.893376E+09 | 2431690.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.173375E+09 | 0.242855E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.289044E+09 | 0.391613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.372918E+09 | 0.503929E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.383075E+09 | 0.526945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.392610E+09 | 0.562321E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.366132E+09 | 0.531481E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.321978E+09 | 0.464597E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.251546E+09 | 0.354781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.135163E+09 | 0.192301E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 36648079.28 | 0.524722E+09 | 4754744.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.280592E+10 | 0.394128E+11 | 26817068.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 21277142.94 | 0.286517E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.392610E+09 | 0.562321E+10 | 19630634.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 29999556.23 | 0.00 | 0.00 | 0.00 | 0.108234E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 60027037.34 | 0.00 | 0.00 | 0.00 | 0.218187E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.152754E+09 | 0.00 | 0.00 | 0.00 | 0.570912E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.270095E+09 | 0.00 | 0.00 | 0.00 | 0.104971E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.371156E+09 | 0.00 | 0.00 | 0.00 | 0.148875E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.402786E+09 | 0.00 | 0.00 | 0.00 | 0.163672E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.435069E+09 | 0.00 | 0.00 | 0.00 | 0.175435E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.424514E+09 | 0.00 | 0.00 | 0.00 | 0.168508E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.386220E+09 | 0.00 | 0.00 | 0.00 | 0.150731E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.304517E+09 | 0.00 | 0.00 | 0.00 | 0.115476E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.178789E+09 | 0.00 | 0.00 | 0.00 | 0.658430E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 71525132.78 | 0.00 | 0.00 | 0.00 | 0.258198E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.308745E+10 | 0.00 | 0.00 | 0.00 | 0.120906E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 29999556.23 | 0.00 | 0.00 | 0.00 | 0.108234E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.435069E+09 | 0.00 | 0.00 | 0.00 | 0.175435E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 1408500.34 | 0.00 | 0.00 | 651707.95 | 4508575.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 18222145.13 | 0.00 | 0.00 | 0.00 | 66083093.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.103893E+09 | 0.00 | 0.00 | 0.00 | 0.387181E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.238206E+09 | 0.00 | 0.00 | 0.00 | 0.920688E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.367031E+09 | 0.00 | 0.00 | 0.00 | 0.146290E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.407423E+09 | 0.00 | 0.00 | 0.00 | 0.164520E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.438287E+09 | 0.00 | 0.00 | 0.00 | 0.175590E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.421710E+09 | 0.00 | 0.00 | 0.00 | 0.166356E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.361325E+09 | 0.00 | 0.00 | 0.00 | 0.140167E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.238460E+09 | 0.00 | 0.00 | 0.00 | 0.899542E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.100726E+09 | 0.00 | 0.00 | 0.00 | 0.369592E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 13175828.76 | 0.00 | 0.00 | 0.00 | 47302093.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.270987E+10 | 0.00 | 0.00 | 651707.95 | 0.106241E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 1408500.34 | 0.00 | 0.00 | 0.00 | 4508575.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.438287E+09 | 0.00 | 0.00 | 651707.95 | 0.175590E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.122128E+10 | 0.00 | 0.00 | 39568.38 | 0.184840E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.110558E+10 | 0.00 | 0.00 | 0.00 | 0.278854E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.122777E+10 | 0.00 | 0.00 | 0.00 | 0.545919E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.120437E+10 | 0.00 | 0.00 | 0.00 | 0.831992E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.125113E+10 | 0.00 | 0.00 | 0.00 | 0.130252E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.121227E+10 | 0.00 | 0.00 | 0.00 | 0.142442E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.125651E+10 | 0.00 | 0.00 | 0.00 | 0.143957E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.125387E+10 | 0.00 | 0.00 | 0.00 | 0.143325E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.121395E+10 | 0.00 | 0.00 | 0.00 | 0.115961E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.124920E+10 | 0.00 | 0.00 | 0.00 | 0.929854E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.119957E+10 | 0.00 | 0.00 | 0.00 | 0.565873E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.122750E+10 | 0.00 | 0.00 | 0.00 | 0.289239E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.146230E+11 | 0.00 | 0.00 | 39568.38 | 0.103859E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.110558E+10 | 0.00 | 0.00 | 0.00 | 0.184840E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.125651E+10 | 0.00 | 0.00 | 39568.38 | 0.143957E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 1299753.31 | 0.00 | 0.00 | 575000.88 | 4201895.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 18443714.14 | 0.00 | 0.00 | 0.00 | 67152036.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.103183E+09 | 0.00 | 0.00 | 0.00 | 0.386005E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.238404E+09 | 0.00 | 0.00 | 0.00 | 0.924185E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.367132E+09 | 0.00 | 0.00 | 0.00 | 0.146793E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.401296E+09 | 0.00 | 0.00 | 0.00 | 0.162600E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.436121E+09 | 0.00 | 0.00 | 0.00 | 0.175330E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.419686E+09 | 0.00 | 0.00 | 0.00 | 0.166122E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.358364E+09 | 0.00 | 0.00 | 0.00 | 0.139488E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.238324E+09 | 0.00 | 0.00 | 0.00 | 0.902138E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 99626368.86 | 0.00 | 0.00 | 0.00 | 0.366922E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 12774255.54 | 0.00 | 0.00 | 0.00 | 46037767.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.269465E+10 | 0.00 | 0.00 | 575000.88 | 0.106000E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 1299753.31 | 0.00 | 0.00 | 0.00 | 4201895.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.436121E+09 | 0.00 | 0.00 | 575000.88 | 0.175330E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 5523070.15 | 0.00 | 0.00 | 0.00 | 20272540.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 23726619.85 | 0.00 | 0.00 | 0.00 | 87377672.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 96245285.04 | 0.00 | 0.00 | 0.00 | 0.363515E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.195646E+09 | 0.00 | 0.00 | 0.00 | 0.767634E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.296947E+09 | 0.00 | 0.00 | 0.00 | 0.120407E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.329976E+09 | 0.00 | 0.00 | 0.00 | 0.135749E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.361813E+09 | 0.00 | 0.00 | 0.00 | 0.147765E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.349848E+09 | 0.00 | 0.00 | 0.00 | 0.140654E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.299090E+09 | 0.00 | 0.00 | 0.00 | 0.118146E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.198645E+09 | 0.00 | 0.00 | 0.00 | 0.761549E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 93275425.52 | 0.00 | 0.00 | 0.00 | 0.347423E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 25356784.65 | 0.00 | 0.00 | 0.00 | 92628668.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.227609E+10 | 0.00 | 0.00 | 0.00 | 0.906760E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 5523070.15 | 0.00 | 0.00 | 0.00 | 20272540.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.361813E+09 | 0.00 | 0.00 | 0.00 | 0.147765E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 5545185.00 | 0.00 | 0.00 | 0.00 | 20355072.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 23954834.71 | 0.00 | 0.00 | 0.00 | 88227036.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 96459307.29 | 0.00 | 0.00 | 0.00 | 0.364379E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.195653E+09 | 0.00 | 0.00 | 0.00 | 0.767825E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.296834E+09 | 0.00 | 0.00 | 0.00 | 0.120390E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.329631E+09 | 0.00 | 0.00 | 0.00 | 0.135639E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.361612E+09 | 0.00 | 0.00 | 0.00 | 0.147710E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.349666E+09 | 0.00 | 0.00 | 0.00 | 0.140603E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.298876E+09 | 0.00 | 0.00 | 0.00 | 0.118080E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.198632E+09 | 0.00 | 0.00 | 0.00 | 0.761636E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 93371981.88 | 0.00 | 0.00 | 0.00 | 0.347836E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 25373339.50 | 0.00 | 0.00 | 0.00 | 92698890.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.227561E+10 | 0.00 | 0.00 | 0.00 | 0.906717E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 5545185.00 | 0.00 | 0.00 | 0.00 | 20355072.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.361612E+09 | 0.00 | 0.00 | 0.00 | 0.147710E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 51181295.79 | 0.00 | 0.00 | 0.00 | 0.188894E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 74098989.51 | 0.00 | 0.00 | 0.00 | 0.275186E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.145873E+09 | 0.00 | 0.00 | 0.00 | 0.556030E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.227561E+09 | 0.00 | 0.00 | 0.00 | 0.902823E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.300876E+09 | 0.00 | 0.00 | 0.00 | 0.123446E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.324860E+09 | 0.00 | 0.00 | 0.00 | 0.135220E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.358037E+09 | 0.00 | 0.00 | 0.00 | 0.147973E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.352131E+09 | 0.00 | 0.00 | 0.00 | 0.143223E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.323736E+09 | 0.00 | 0.00 | 0.00 | 0.129348E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.264098E+09 | 0.00 | 0.00 | 0.00 | 0.102352E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.171069E+09 | 0.00 | 0.00 | 0.00 | 0.643488E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 91157243.45 | 0.00 | 0.00 | 0.00 | 0.336427E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.268468E+10 | 0.00 | 0.00 | 0.00 | 0.107185E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 51181295.79 | 0.00 | 0.00 | 0.00 | 0.188894E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.358037E+09 | 0.00 | 0.00 | 0.00 | 0.147973E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT GS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 50341504.01 | 0.00 | 0.00 | 0.00 | 0.185612E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 76204852.86 | 0.00 | 0.00 | 0.00 | 0.282724E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.154486E+09 | 0.00 | 0.00 | 0.00 | 0.587994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.245885E+09 | 0.00 | 0.00 | 0.00 | 0.973365E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.324303E+09 | 0.00 | 0.00 | 0.00 | 0.132726E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.347463E+09 | 0.00 | 0.00 | 0.00 | 0.144240E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.382820E+09 | 0.00 | 0.00 | 0.00 | 0.157782E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.375429E+09 | 0.00 | 0.00 | 0.00 | 0.152304E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.346142E+09 | 0.00 | 0.00 | 0.00 | 0.137960E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.281768E+09 | 0.00 | 0.00 | 0.00 | 0.108984E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.180617E+09 | 0.00 | 0.00 | 0.00 | 0.678467E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 92651440.35 | 0.00 | 0.00 | 0.00 | 0.341594E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.285811E+10 | 0.00 | 0.00 | 0.00 | 0.113897E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 50341504.01 | 0.00 | 0.00 | 0.00 | 0.185612E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.382820E+09 | 0.00 | 0.00 | 0.00 | 0.157782E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 83649700.62 | 0.00 | 0.00 | 0.00 | 0.298784E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.176285E+09 | 0.00 | 0.00 | 0.00 | 0.634123E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.409709E+09 | 0.00 | 0.00 | 0.00 | 0.151303E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.648822E+09 | 0.00 | 0.00 | 0.00 | 0.249465E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.817461E+09 | 0.00 | 0.00 | 0.00 | 0.324678E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.830117E+09 | 0.00 | 0.00 | 0.00 | 0.334355E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.838497E+09 | 0.00 | 0.00 | 0.00 | 0.335821E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.780840E+09 | 0.00 | 0.00 | 0.00 | 0.308163E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.700458E+09 | 0.00 | 0.00 | 0.00 | 0.271847E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.563204E+09 | 0.00 | 0.00 | 0.00 | 0.212270E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.336250E+09 | 0.00 | 0.00 | 0.00 | 0.122885E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.135044E+09 | 0.00 | 0.00 | 0.00 | 0.482760E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.632034E+10 | 0.00 | 0.00 | 0.00 | 0.245235E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 83649700.62 | 0.00 | 0.00 | 0.00 | 0.298784E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.838497E+09 | 0.00 | 0.00 | 0.00 | 0.335821E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 6633325.19 | 0.00 | 0.00 | 104019.44 | 23631380.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 72473816.49 | 0.00 | 0.00 | 0.00 | 0.260103E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.304732E+09 | 0.00 | 0.00 | 0.00 | 0.112164E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.580179E+09 | 0.00 | 0.00 | 0.00 | 0.222030E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.806823E+09 | 0.00 | 0.00 | 0.00 | 0.318842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.837112E+09 | 0.00 | 0.00 | 0.00 | 0.335528E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.841845E+09 | 0.00 | 0.00 | 0.00 | 0.335460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.771008E+09 | 0.00 | 0.00 | 0.00 | 0.302834E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.642762E+09 | 0.00 | 0.00 | 0.00 | 0.248325E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.419419E+09 | 0.00 | 0.00 | 0.00 | 0.157466E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.168634E+09 | 0.00 | 0.00 | 0.00 | 0.615344E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 18480835.58 | 0.00 | 0.00 | 0.00 | 65846955.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.547010E+10 | 0.00 | 0.00 | 104019.44 | 0.212914E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 6633325.19 | 0.00 | 0.00 | 0.00 | 23631380.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.841845E+09 | 0.00 | 0.00 | 104019.44 | 0.335528E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MSE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 85751157.02 | 0.00 | 0.00 | 0.00 | 0.307654E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.178934E+09 | 0.00 | 0.00 | 0.00 | 0.646606E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.408655E+09 | 0.00 | 0.00 | 0.00 | 0.151566E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.647913E+09 | 0.00 | 0.00 | 0.00 | 0.250048E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.816925E+09 | 0.00 | 0.00 | 0.00 | 0.325721E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.816493E+09 | 0.00 | 0.00 | 0.00 | 0.330227E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.833964E+09 | 0.00 | 0.00 | 0.00 | 0.335424E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.776823E+09 | 0.00 | 0.00 | 0.00 | 0.307854E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.694142E+09 | 0.00 | 0.00 | 0.00 | 0.270497E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.562768E+09 | 0.00 | 0.00 | 0.00 | 0.212978E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.333542E+09 | 0.00 | 0.00 | 0.00 | 0.122433E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.135637E+09 | 0.00 | 0.00 | 0.00 | 0.487080E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.629155E+10 | 0.00 | 0.00 | 0.00 | 0.245088E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 85751157.02 | 0.00 | 0.00 | 0.00 | 0.307654E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.833964E+09 | 0.00 | 0.00 | 0.00 | 0.335424E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 6420956.72 | 0.00 | 0.00 | 264938.39 | 22822008.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 73513930.77 | 0.00 | 0.00 | 0.00 | 0.264859E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.303382E+09 | 0.00 | 0.00 | 0.00 | 0.112086E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.580166E+09 | 0.00 | 0.00 | 0.00 | 0.222671E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.806875E+09 | 0.00 | 0.00 | 0.00 | 0.319850E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.823892E+09 | 0.00 | 0.00 | 0.00 | 0.331337E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.837814E+09 | 0.00 | 0.00 | 0.00 | 0.335006E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.767576E+09 | 0.00 | 0.00 | 0.00 | 0.302497E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.637345E+09 | 0.00 | 0.00 | 0.00 | 0.247032E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.419782E+09 | 0.00 | 0.00 | 0.00 | 0.158144E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.164491E+09 | 0.00 | 0.00 | 0.00 | 0.602633E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 16853989.90 | 0.00 | 0.00 | 0.00 | 60283318.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.543811E+10 | 0.00 | 0.00 | 264938.39 | 0.212368E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 6420956.72 | 0.00 | 0.00 | 0.00 | 22822008.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.837814E+09 | 0.00 | 0.00 | 264938.39 | 0.335006E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 22942566.82 | 0.00 | 0.00 | 0.00 | 83392330.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 86167114.82 | 0.00 | 0.00 | 0.00 | 0.314207E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.258220E+09 | 0.00 | 0.00 | 0.00 | 0.964731E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.446943E+09 | 0.00 | 0.00 | 0.00 | 0.173776E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.621601E+09 | 0.00 | 0.00 | 0.00 | 0.250082E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.654674E+09 | 0.00 | 0.00 | 0.00 | 0.267505E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.684258E+09 | 0.00 | 0.00 | 0.00 | 0.277994E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.638267E+09 | 0.00 | 0.00 | 0.00 | 0.255433E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.533502E+09 | 0.00 | 0.00 | 0.00 | 0.209772E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.351161E+09 | 0.00 | 0.00 | 0.00 | 0.133895E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.163064E+09 | 0.00 | 0.00 | 0.00 | 0.603452E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 45140998.13 | 0.00 | 0.00 | 0.00 | 0.163665E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.450594E+10 | 0.00 | 0.00 | 0.00 | 0.178140E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 22942566.82 | 0.00 | 0.00 | 0.00 | 83392330.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.684258E+09 | 0.00 | 0.00 | 0.00 | 0.277994E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 23074559.29 | 0.00 | 0.00 | 0.00 | 83875457.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 86773242.68 | 0.00 | 0.00 | 0.00 | 0.316439E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.258967E+09 | 0.00 | 0.00 | 0.00 | 0.967601E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.447214E+09 | 0.00 | 0.00 | 0.00 | 0.173896E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.621728E+09 | 0.00 | 0.00 | 0.00 | 0.250155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.654378E+09 | 0.00 | 0.00 | 0.00 | 0.267407E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.684221E+09 | 0.00 | 0.00 | 0.00 | 0.278001E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.638246E+09 | 0.00 | 0.00 | 0.00 | 0.255444E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.533401E+09 | 0.00 | 0.00 | 0.00 | 0.209750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.351506E+09 | 0.00 | 0.00 | 0.00 | 0.134038E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.163396E+09 | 0.00 | 0.00 | 0.00 | 0.604749E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 45243505.75 | 0.00 | 0.00 | 0.00 | 0.164048E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.450815E+10 | 0.00 | 0.00 | 0.00 | 0.178236E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 23074559.29 | 0.00 | 0.00 | 0.00 | 83875457.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.684221E+09 | 0.00 | 0.00 | 0.00 | 0.278001E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.136526E+09 | 0.00 | 0.00 | 0.00 | 0.498792E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.197318E+09 | 0.00 | 0.00 | 0.00 | 0.725170E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.361532E+09 | 0.00 | 0.00 | 0.00 | 0.136254E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.513684E+09 | 0.00 | 0.00 | 0.00 | 0.201683E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.630433E+09 | 0.00 | 0.00 | 0.00 | 0.256159E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.645595E+09 | 0.00 | 0.00 | 0.00 | 0.266380E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.678579E+09 | 0.00 | 0.00 | 0.00 | 0.278448E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.645834E+09 | 0.00 | 0.00 | 0.00 | 0.260977E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.589130E+09 | 0.00 | 0.00 | 0.00 | 0.233868E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.492623E+09 | 0.00 | 0.00 | 0.00 | 0.189569E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.330985E+09 | 0.00 | 0.00 | 0.00 | 0.123443E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.186511E+09 | 0.00 | 0.00 | 0.00 | 0.681587E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.540875E+10 | 0.00 | 0.00 | 0.00 | 0.213733E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.136526E+09 | 0.00 | 0.00 | 0.00 | 0.498792E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.678579E+09 | 0.00 | 0.00 | 0.00 | 0.278448E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT MS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 0.136706E+09 | 0.00 | 0.00 | 0.00 | 0.499503E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.197815E+09 | 0.00 | 0.00 | 0.00 | 0.727075E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.362089E+09 | 0.00 | 0.00 | 0.00 | 0.136478E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.513901E+09 | 0.00 | 0.00 | 0.00 | 0.201789E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.630545E+09 | 0.00 | 0.00 | 0.00 | 0.256232E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.645291E+09 | 0.00 | 0.00 | 0.00 | 0.266282E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.678530E+09 | 0.00 | 0.00 | 0.00 | 0.278456E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.645799E+09 | 0.00 | 0.00 | 0.00 | 0.260988E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.589008E+09 | 0.00 | 0.00 | 0.00 | 0.233843E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.492837E+09 | 0.00 | 0.00 | 0.00 | 0.189671E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.331278E+09 | 0.00 | 0.00 | 0.00 | 0.123566E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.186725E+09 | 0.00 | 0.00 | 0.00 | 0.682438E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.541053E+10 | 0.00 | 0.00 | 0.00 | 0.213821E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.136706E+09 | 0.00 | 0.00 | 0.00 | 0.499503E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.678530E+09 | 0.00 | 0.00 | 0.00 | 0.278456E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TSW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 29169870.54 | 0.00 | 0.00 | 47034507.92 | 62133219.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 64179745.78 | 0.00 | 0.00 | 6239405.61 | 0.223692E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.198503E+09 | 0.00 | 0.00 | 0.00 | 0.730420E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.356684E+09 | 0.00 | 0.00 | 0.00 | 0.136570E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.466719E+09 | 0.00 | 0.00 | 0.00 | 0.184065E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.475933E+09 | 0.00 | 0.00 | 0.00 | 0.190000E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.472460E+09 | 0.00 | 0.00 | 0.00 | 0.187398E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.432847E+09 | 0.00 | 0.00 | 0.00 | 0.169293E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.376182E+09 | 0.00 | 0.00 | 0.00 | 0.144953E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.286173E+09 | 0.00 | 0.00 | 0.00 | 0.107507E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.143667E+09 | 0.00 | 0.00 | 0.00 | 0.522948E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 36365917.04 | 0.00 | 0.00 | 16223697.71 | 0.114585E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.333888E+10 | 0.00 | 0.00 | 69497611.24 | 0.128516E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 29169870.54 | 0.00 | 0.00 | 0.00 | 62133219.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.475933E+09 | 0.00 | 0.00 | 47034507.92 | 0.190000E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TNW
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 29000578.59 | 0.00 | 0.00 | 0.117944E+09 | 355477.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 26127490.62 | 0.00 | 0.00 | 16430628.80 | 79127678.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.144895E+09 | 0.00 | 0.00 | 0.00 | 0.532725E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.320033E+09 | 0.00 | 0.00 | 0.00 | 0.122169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.460624E+09 | 0.00 | 0.00 | 0.00 | 0.181046E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.478836E+09 | 0.00 | 0.00 | 0.00 | 0.190554E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.473652E+09 | 0.00 | 0.00 | 0.00 | 0.187240E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.426905E+09 | 0.00 | 0.00 | 0.00 | 0.166450E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.345275E+09 | 0.00 | 0.00 | 0.00 | 0.132656E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.210043E+09 | 0.00 | 0.00 | 0.00 | 0.787722E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 63482781.37 | 0.00 | 0.00 | 0.00 | 0.231616E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 14636216.52 | 0.00 | 0.00 | 54898132.09 | 4582048.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.299351E+10 | 0.00 | 0.00 | 0.189273E+09 | 0.114373E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 14636216.52 | 0.00 | 0.00 | 0.00 | 355477.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.478836E+09 | 0.00 | 0.00 | 0.117944E+09 | 0.190554E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TSE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 26585892.98 | 0.00 | 0.00 | 44157831.58 | 55881625.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 63326909.47 | 0.00 | 0.00 | 5693581.94 | 0.222250E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.196668E+09 | 0.00 | 0.00 | 0.00 | 0.726836E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.355559E+09 | 0.00 | 0.00 | 0.00 | 0.136631E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.465617E+09 | 0.00 | 0.00 | 0.00 | 0.184345E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.467820E+09 | 0.00 | 0.00 | 0.00 | 0.187546E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.469147E+09 | 0.00 | 0.00 | 0.00 | 0.186893E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.430067E+09 | 0.00 | 0.00 | 0.00 | 0.168919E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.372427E+09 | 0.00 | 0.00 | 0.00 | 0.144091E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.285619E+09 | 0.00 | 0.00 | 0.00 | 0.107734E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.141499E+09 | 0.00 | 0.00 | 0.00 | 0.517388E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 34278331.41 | 0.00 | 0.00 | 15458770.83 | 0.108415E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.330861E+10 | 0.00 | 0.00 | 65310184.35 | 0.127923E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 26585892.98 | 0.00 | 0.00 | 0.00 | 55881625.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.469147E+09 | 0.00 | 0.00 | 44157831.58 | 0.187546E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TNE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 27137154.69 | 0.00 | 0.00 | 0.110549E+09 | 188969.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 24685188.41 | 0.00 | 0.00 | 14808277.91 | 75762064.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.142627E+09 | 0.00 | 0.00 | 0.00 | 0.526617E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.319362E+09 | 0.00 | 0.00 | 0.00 | 0.122285E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.459831E+09 | 0.00 | 0.00 | 0.00 | 0.181348E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.470917E+09 | 0.00 | 0.00 | 0.00 | 0.188096E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.470569E+09 | 0.00 | 0.00 | 0.00 | 0.186737E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.424415E+09 | 0.00 | 0.00 | 0.00 | 0.166098E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.342050E+09 | 0.00 | 0.00 | 0.00 | 0.131881E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.209781E+09 | 0.00 | 0.00 | 0.00 | 0.789665E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 60889200.77 | 0.00 | 0.00 | 0.00 | 0.223250E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 13768675.97 | 0.00 | 0.00 | 52593429.33 | 3576136.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.296603E+10 | 0.00 | 0.00 | 0.177950E+09 | 0.113835E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 13768675.97 | 0.00 | 0.00 | 0.00 | 188969.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.470917E+09 | 0.00 | 0.00 | 0.110549E+09 | 0.188096E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TN1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 12952413.47 | 0.00 | 0.00 | 52055242.60 | 997958.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 19821542.51 | 0.00 | 0.00 | 3075826.68 | 68982676.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.118712E+09 | 0.00 | 0.00 | 0.00 | 0.441077E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.252407E+09 | 0.00 | 0.00 | 0.00 | 0.974029E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.367121E+09 | 0.00 | 0.00 | 0.00 | 0.146093E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.386708E+09 | 0.00 | 0.00 | 0.00 | 0.155991E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.394396E+09 | 0.00 | 0.00 | 0.00 | 0.158048E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.360694E+09 | 0.00 | 0.00 | 0.00 | 0.142498E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.291340E+09 | 0.00 | 0.00 | 0.00 | 0.113304E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.175212E+09 | 0.00 | 0.00 | 0.00 | 0.663918E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 52039760.93 | 0.00 | 0.00 | 0.00 | 0.192033E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 5343974.07 | 0.00 | 0.00 | 17281704.91 | 4062283.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.243675E+10 | 0.00 | 0.00 | 72412774.20 | 0.950443E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 5343974.07 | 0.00 | 0.00 | 0.00 | 997958.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.394396E+09 | 0.00 | 0.00 | 52055242.60 | 0.158048E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TN2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 12998453.11 | 0.00 | 0.00 | 52280425.34 | 969620.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 20033404.39 | 0.00 | 0.00 | 3076682.51 | 69762646.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.119140E+09 | 0.00 | 0.00 | 0.00 | 0.442742E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.252553E+09 | 0.00 | 0.00 | 0.00 | 0.974752E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.367162E+09 | 0.00 | 0.00 | 0.00 | 0.146133E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.386479E+09 | 0.00 | 0.00 | 0.00 | 0.155924E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.394318E+09 | 0.00 | 0.00 | 0.00 | 0.158042E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.360634E+09 | 0.00 | 0.00 | 0.00 | 0.142497E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.291256E+09 | 0.00 | 0.00 | 0.00 | 0.113290E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.175427E+09 | 0.00 | 0.00 | 0.00 | 0.664858E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 52264131.29 | 0.00 | 0.00 | 0.00 | 0.192907E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 5348951.75 | 0.00 | 0.00 | 17316669.11 | 4051934.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.243761E+10 | 0.00 | 0.00 | 72673776.96 | 0.950890E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 5348951.75 | 0.00 | 0.00 | 0.00 | 969620.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.394318E+09 | 0.00 | 0.00 | 52280425.34 | 0.158042E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TS1
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 21154325.49 | 0.00 | 0.00 | 6188163.69 | 70441310.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 61829340.55 | 0.00 | 0.00 | 727695.05 | 0.223146E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.173034E+09 | 0.00 | 0.00 | 0.00 | 0.644675E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.288938E+09 | 0.00 | 0.00 | 0.00 | 0.112068E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.372889E+09 | 0.00 | 0.00 | 0.00 | 0.149177E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.383310E+09 | 0.00 | 0.00 | 0.00 | 0.155403E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.392697E+09 | 0.00 | 0.00 | 0.00 | 0.158193E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.366202E+09 | 0.00 | 0.00 | 0.00 | 0.145393E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.322084E+09 | 0.00 | 0.00 | 0.00 | 0.125872E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.251416E+09 | 0.00 | 0.00 | 0.00 | 0.956434E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.134975E+09 | 0.00 | 0.00 | 0.00 | 0.497667E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 36517819.92 | 0.00 | 0.00 | 1539419.55 | 0.129775E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.280505E+10 | 0.00 | 0.00 | 8455278.29 | 0.109832E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 21154325.49 | 0.00 | 0.00 | 0.00 | 70441310.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.392697E+09 | 0.00 | 0.00 | 6188163.69 | 0.158193E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: SPLIT TS2
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| AIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
| January | 21277142.94 | 0.00 | 0.00 | 6217939.03 | 70873512.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 62155355.78 | 0.00 | 0.00 | 734485.02 | 0.224368E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.173375E+09 | 0.00 | 0.00 | 0.00 | 0.646062E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.289044E+09 | 0.00 | 0.00 | 0.00 | 0.112130E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.372918E+09 | 0.00 | 0.00 | 0.00 | 0.149217E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.383075E+09 | 0.00 | 0.00 | 0.00 | 0.155337E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.392610E+09 | 0.00 | 0.00 | 0.00 | 0.158187E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.366132E+09 | 0.00 | 0.00 | 0.00 | 0.145392E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.321978E+09 | 0.00 | 0.00 | 0.00 | 0.125854E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.251546E+09 | 0.00 | 0.00 | 0.00 | 0.957112E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.135163E+09 | 0.00 | 0.00 | 0.00 | 0.498464E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 36648079.28 | 0.00 | 0.00 | 1528117.00 | 0.130279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.280592E+10 | 0.00 | 0.00 | 8480541.06 | 0.109883E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 21277142.94 | 0.00 | 0.00 | 0.00 | 70873512.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.392610E+09 | 0.00 | 0.00 | 6217939.03 | 0.158187E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: G SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.206441E+09 | 84309.19 | 0.00 | 2010755.53 | 209421.62 | 0.00 | 0.120634E+09 | 0.00 | 0.36 |
| February | 93271400.69 | 4713638.83 | 0.00 | 2472988.38 | 2025940.83 | 0.00 | 98567761.22 | 0.00 | 0.36 |
| March | 27345494.60 | 86971147.71 | 0.00 | 1367176.30 | 5197095.44 | 0.00 | 42423522.33 | 0.00 | 0.36 |
| April | 3931559.07 | 0.287179E+09 | 0.00 | 219456.61 | 3665567.81 | 0.00 | 3564173.33 | 0.00 | 0.36 |
| May | 0.00 | 0.727892E+09 | 0.00 | 0.00 | 692216.04 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.107026E+10 | 0.00 | 0.00 | 2007716.58 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.147104E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.150222E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.117786E+10 | 0.00 | 0.00 | 1723868.89 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 7506713.65 | 0.327169E+09 | 0.00 | 190785.55 | 25722581.54 | 0.00 | 1290692.98 | 0.00 | 0.36 |
| November | 30946716.18 | 39593411.09 | 0.00 | 3245040.41 | 6414747.60 | 0.00 | 74602094.93 | 0.00 | 0.36 |
| December | 71239308.40 | 736887.29 | 0.00 | 3612823.43 | 643986.83 | 0.00 | 0.219818E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.440682E+09 | 0.669572E+10 | 0.00 | 13119026.20 | 48303143.19 | 0.00 | 0.560901E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 84309.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.206441E+09 | 0.150222E+10 | 0.00 | 3612823.43 | 25722581.54 | 0.00 | 0.219818E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.278413E+09 | 0.00 | 0.00 | 84892.54 | 545637.64 | 0.00 | 17208029.14 | 0.00 | 0.35 |
| February | 0.152521E+09 | 3171124.01 | 0.00 | 464394.35 | 1529321.94 | 0.00 | 38345564.22 | 0.00 | 0.36 |
| March | 33901685.61 | 76390973.16 | 0.00 | 820175.79 | 5285854.14 | 0.00 | 44334998.19 | 0.00 | 0.36 |
| April | 4137923.13 | 0.279770E+09 | 0.00 | 183270.14 | 3602710.06 | 0.00 | 3508643.96 | 0.00 | 0.36 |
| May | 0.00 | 0.726173E+09 | 0.00 | 0.00 | 712158.61 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.107069E+10 | 0.00 | 0.00 | 2002638.31 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.147175E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.149754E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.116222E+10 | 0.00 | 0.00 | 1765746.62 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 7764891.29 | 0.303533E+09 | 0.00 | 160440.05 | 25248109.12 | 0.00 | 2129593.26 | 0.00 | 0.36 |
| November | 38924662.65 | 30392487.28 | 0.00 | 1578268.44 | 6179166.45 | 0.00 | 79711483.60 | 0.00 | 0.36 |
| December | 0.173404E+09 | 321880.59 | 0.00 | 668582.76 | 715942.56 | 0.00 | 0.124644E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.689068E+09 | 0.662196E+10 | 0.00 | 3960024.07 | 47587285.44 | 0.00 | 0.309883E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.278413E+09 | 0.149754E+10 | 0.00 | 1578268.44 | 25248109.12 | 0.00 | 0.124644E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: OFFICE
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.114418E+10 | 0.00 | 0.00 | 2109049.77 | 0.00 | 46037.30 | 0.175262E+09 | 0.00 | 0.50 |
| February | 0.757237E+09 | 5495080.93 | 0.00 | 2731712.59 | 214796.67 | 0.00 | 0.130840E+09 | 0.00 | 0.50 |
| March | 0.448943E+09 | 83318854.42 | 0.00 | 2599708.95 | 21170724.54 | 0.00 | 68475947.59 | 0.00 | 0.51 |
| April | 0.136783E+09 | 0.302572E+09 | 0.00 | 967846.65 | 0.119927E+09 | 0.00 | 5163129.08 | 0.00 | 0.52 |
| May | 47680060.01 | 0.819225E+09 | 0.00 | 273192.18 | 0.290160E+09 | 0.00 | 4265.04 | 0.00 | 0.53 |
| June | 28517472.09 | 0.107700E+10 | 0.00 | 100478.73 | 0.454153E+09 | 0.00 | 1497252.57 | 0.00 | 0.53 |
| July | 10965352.92 | 0.143730E+10 | 0.00 | 43791.45 | 0.439449E+09 | 0.00 | 0.00 | 0.00 | 0.54 |
| August | 30867152.33 | 0.141008E+10 | 0.00 | 201455.56 | 0.401817E+09 | 0.00 | 27988.01 | 0.00 | 0.53 |
| September | 67425855.97 | 0.961728E+09 | 0.00 | 630337.69 | 0.243032E+09 | 0.00 | 507805.32 | 0.00 | 0.53 |
| October | 0.352487E+09 | 0.319690E+09 | 0.00 | 2020538.38 | 45402332.22 | 0.00 | 24692758.15 | 0.00 | 0.52 |
| November | 0.728156E+09 | 44957473.84 | 0.00 | 3811029.72 | 2803436.83 | 0.00 | 87347120.24 | 0.00 | 0.51 |
| December | 0.108139E+10 | 5171.69 | 0.00 | 3925615.11 | 0.00 | 0.00 | 0.198408E+09 | 0.00 | 0.50 |
| Annual Sum or Average | 0.483464E+10 | 0.646136E+10 | 0.00 | 19414756.80 | 0.201813E+10 | 46037.30 | 0.692226E+09 | 0.00 | 0.52 |
| Minimum of Months | 10965352.92 | 0.00 | 0.00 | 43791.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 |
| Maximum of Months | 0.114418E+10 | 0.143730E+10 | 0.00 | 3925615.11 | 0.454153E+09 | 46037.30 | 0.198408E+09 | 0.00 | 0.54 |
Report: MechanicalVentilationLoadsMonthly
For: G NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.278598E+09 | 0.00 | 0.00 | 77194.90 | 627669.69 | 0.00 | 17971629.95 | 0.00 | 0.35 |
| February | 0.148476E+09 | 3213209.09 | 0.00 | 501450.77 | 1579261.33 | 0.00 | 43591044.74 | 0.00 | 0.36 |
| March | 34422528.79 | 77852189.68 | 0.00 | 856287.35 | 4813820.21 | 0.00 | 44835034.49 | 0.00 | 0.36 |
| April | 3979853.44 | 0.282587E+09 | 0.00 | 205559.42 | 3400019.86 | 0.00 | 3842536.60 | 0.00 | 0.36 |
| May | 0.00 | 0.727753E+09 | 0.00 | 0.00 | 677779.42 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.106964E+10 | 0.00 | 0.00 | 1971146.83 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.147230E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.149821E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.116205E+10 | 0.00 | 0.00 | 1696552.33 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 8194652.24 | 0.305268E+09 | 0.00 | 170859.90 | 25232105.87 | 0.00 | 2123541.26 | 0.00 | 0.36 |
| November | 39756057.29 | 30891192.95 | 0.00 | 1632572.58 | 5913392.01 | 0.00 | 80710787.72 | 0.00 | 0.36 |
| December | 0.173419E+09 | 315221.80 | 0.00 | 649589.73 | 696285.10 | 0.00 | 0.125860E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.686846E+09 | 0.663009E+10 | 0.00 | 4093514.65 | 46608032.65 | 0.00 | 0.318935E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.278598E+09 | 0.149821E+10 | 0.00 | 1632572.58 | 25232105.87 | 0.00 | 0.125860E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.246288E+09 | 0.00 | 0.00 | 297170.82 | 491547.55 | 0.00 | 62646657.16 | 0.00 | 0.35 |
| February | 0.116720E+09 | 3126678.90 | 0.00 | 803066.20 | 1529168.09 | 0.00 | 76279819.49 | 0.00 | 0.36 |
| March | 30329116.11 | 74947404.00 | 0.00 | 985078.11 | 5162075.55 | 0.00 | 44487220.39 | 0.00 | 0.36 |
| April | 4167526.37 | 0.273219E+09 | 0.00 | 190155.93 | 3680086.13 | 0.00 | 3585038.20 | 0.00 | 0.36 |
| May | 0.00 | 0.707744E+09 | 0.00 | 0.00 | 709094.09 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.104040E+10 | 0.00 | 0.00 | 2048759.16 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.143037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.145083E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.112224E+10 | 0.00 | 0.00 | 1617942.35 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 7991444.33 | 0.292093E+09 | 0.00 | 170068.24 | 23878739.04 | 0.00 | 2324482.37 | 0.00 | 0.36 |
| November | 38602307.13 | 29433143.97 | 0.00 | 1768837.44 | 5968964.42 | 0.00 | 77337151.06 | 0.00 | 0.36 |
| December | 93107563.15 | 325568.98 | 0.00 | 1244372.36 | 726866.05 | 0.00 | 0.202485E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.537206E+09 | 0.642472E+10 | 0.00 | 5458749.10 | 45813242.45 | 0.00 | 0.469145E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.246288E+09 | 0.145083E+10 | 0.00 | 1768837.44 | 23878739.04 | 0.00 | 0.202485E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.246348E+09 | 0.00 | 0.00 | 298566.01 | 488575.70 | 0.00 | 62777498.62 | 0.00 | 0.35 |
| February | 0.116357E+09 | 3112101.28 | 0.00 | 811446.18 | 1516013.78 | 0.00 | 76811286.91 | 0.00 | 0.36 |
| March | 30431482.67 | 74682730.69 | 0.00 | 991451.23 | 5122383.14 | 0.00 | 44617441.80 | 0.00 | 0.36 |
| April | 4191949.26 | 0.272391E+09 | 0.00 | 192364.01 | 3655132.32 | 0.00 | 3619157.95 | 0.00 | 0.36 |
| May | 0.00 | 0.706433E+09 | 0.00 | 0.00 | 706220.53 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.103893E+10 | 0.00 | 0.00 | 2044760.59 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.142898E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.144949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.112090E+10 | 0.00 | 0.00 | 1613391.73 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 8034136.00 | 0.291228E+09 | 0.00 | 172254.54 | 23736111.34 | 0.00 | 2370185.73 | 0.00 | 0.36 |
| November | 38771619.93 | 29253026.97 | 0.00 | 1774988.80 | 5906584.06 | 0.00 | 77633793.68 | 0.00 | 0.36 |
| December | 92908299.96 | 325563.44 | 0.00 | 1246166.28 | 722215.18 | 0.00 | 0.202967E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.537043E+09 | 0.641571E+10 | 0.00 | 5487237.05 | 45511388.38 | 0.00 | 0.470797E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.246348E+09 | 0.144949E+10 | 0.00 | 1774988.80 | 23736111.34 | 0.00 | 0.202967E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 90891578.07 | 68121.95 | 0.00 | 3121165.57 | 196111.24 | 0.00 | 0.235494E+09 | 0.00 | 0.36 |
| February | 49808855.86 | 4731022.73 | 0.00 | 3295358.44 | 2100298.62 | 0.00 | 0.135905E+09 | 0.00 | 0.36 |
| March | 26451445.58 | 86480111.54 | 0.00 | 1588896.15 | 5112679.71 | 0.00 | 40833941.12 | 0.00 | 0.36 |
| April | 4020400.92 | 0.281869E+09 | 0.00 | 240593.89 | 3525287.64 | 0.00 | 3646509.77 | 0.00 | 0.36 |
| May | 0.00 | 0.709800E+09 | 0.00 | 0.00 | 690336.01 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.103943E+10 | 0.00 | 0.00 | 2053730.79 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.142950E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.145708E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.114319E+10 | 0.00 | 0.00 | 1660530.43 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 7732715.38 | 0.319215E+09 | 0.00 | 209271.83 | 24777423.41 | 0.00 | 1333036.29 | 0.00 | 0.36 |
| November | 31455873.35 | 39109210.43 | 0.00 | 3526834.37 | 6310155.97 | 0.00 | 72306318.18 | 0.00 | 0.36 |
| December | 44964798.16 | 696198.24 | 0.00 | 4497564.59 | 693941.12 | 0.00 | 0.242219E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.255326E+09 | 0.651116E+10 | 0.00 | 16479684.84 | 47120494.94 | 0.00 | 0.731737E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 68121.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 90891578.07 | 0.145708E+10 | 0.00 | 4497564.59 | 24777423.41 | 0.00 | 0.242219E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: G S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 94819244.12 | 70456.91 | 0.00 | 3065594.79 | 194447.49 | 0.00 | 0.231280E+09 | 0.00 | 0.36 |
| February | 49728082.98 | 4750068.90 | 0.00 | 3349958.28 | 2101693.95 | 0.00 | 0.135641E+09 | 0.00 | 0.36 |
| March | 25958942.94 | 88390366.19 | 0.00 | 1649282.11 | 4981637.85 | 0.00 | 40400183.85 | 0.00 | 0.36 |
| April | 3888785.73 | 0.287635E+09 | 0.00 | 263912.98 | 3629024.30 | 0.00 | 3641533.83 | 0.00 | 0.36 |
| May | 0.00 | 0.722364E+09 | 0.00 | 0.00 | 745386.84 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.105646E+10 | 0.00 | 0.00 | 2003957.52 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.145353E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.148159E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.116514E+10 | 0.00 | 0.00 | 1659393.55 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 7792826.70 | 0.326146E+09 | 0.00 | 203561.80 | 25713320.76 | 0.00 | 1079967.77 | 0.00 | 0.36 |
| November | 31881862.61 | 39585033.45 | 0.00 | 3706607.88 | 6303069.25 | 0.00 | 70205627.99 | 0.00 | 0.36 |
| December | 45082724.74 | 684813.83 | 0.00 | 4541702.33 | 696964.59 | 0.00 | 0.242017E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.259152E+09 | 0.662634E+10 | 0.00 | 16780620.18 | 48028896.12 | 0.00 | 0.724265E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 70456.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 94819244.12 | 0.148159E+10 | 0.00 | 4541702.33 | 25713320.76 | 0.00 | 0.242017E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.385312E+09 | 192972.44 | 0.00 | 5029209.71 | 337955.69 | 0.00 | 0.270344E+09 | 0.00 | 0.36 |
| February | 0.139696E+09 | 10236202.69 | 0.00 | 6743725.84 | 4061341.32 | 0.00 | 0.231088E+09 | 0.00 | 0.36 |
| March | 49318011.12 | 0.186329E+09 | 0.00 | 3540208.33 | 10469781.08 | 0.00 | 77230787.33 | 0.00 | 0.36 |
| April | 7299598.87 | 0.595934E+09 | 0.00 | 462636.14 | 7239207.50 | 0.00 | 6460167.75 | 0.00 | 0.36 |
| May | 0.00 | 0.147094E+10 | 0.00 | 0.00 | 1334518.55 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.213137E+10 | 0.00 | 0.00 | 4059946.50 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.287319E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.289978E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.225549E+10 | 0.00 | 0.00 | 3466903.07 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 15273477.02 | 0.623183E+09 | 0.00 | 359937.75 | 46814470.59 | 0.00 | 4987472.70 | 0.00 | 0.36 |
| November | 63328734.29 | 78268970.00 | 0.00 | 5613935.85 | 12561827.29 | 0.00 | 0.162638E+09 | 0.00 | 0.36 |
| December | 0.179429E+09 | 1610707.43 | 0.00 | 6793259.05 | 1176379.97 | 0.00 | 0.404167E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.839657E+09 | 0.131265E+11 | 0.00 | 28542912.68 | 91522331.57 | 0.00 | 0.115691E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 192972.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.385312E+09 | 0.289978E+10 | 0.00 | 6793259.05 | 46814470.59 | 0.00 | 0.404167E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.544002E+09 | 0.00 | 0.00 | 346274.66 | 878300.47 | 0.00 | 54955243.95 | 0.00 | 0.35 |
| February | 0.239047E+09 | 7409458.30 | 0.00 | 1995500.86 | 2716589.07 | 0.00 | 0.138793E+09 | 0.00 | 0.36 |
| March | 55887662.04 | 0.169526E+09 | 0.00 | 2491905.46 | 10681787.80 | 0.00 | 80732696.80 | 0.00 | 0.36 |
| April | 7320874.15 | 0.585690E+09 | 0.00 | 391096.82 | 7161715.02 | 0.00 | 6387954.95 | 0.00 | 0.36 |
| May | 0.00 | 0.146942E+10 | 0.00 | 0.00 | 1368211.56 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.213296E+10 | 0.00 | 0.00 | 4060958.71 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.287478E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.288854E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.221701E+10 | 0.00 | 0.00 | 3277818.11 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 17220745.47 | 0.570963E+09 | 0.00 | 279430.26 | 47144749.35 | 0.00 | 7397490.43 | 0.00 | 0.36 |
| November | 96112173.33 | 59000942.06 | 0.00 | 2250227.29 | 12832198.63 | 0.00 | 0.157595E+09 | 0.00 | 0.36 |
| December | 0.462188E+09 | 745337.42 | 0.00 | 878222.78 | 1796425.91 | 0.00 | 0.120537E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.142178E+10 | 0.129760E+11 | 0.00 | 8632658.13 | 91918754.65 | 0.00 | 0.566399E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.544002E+09 | 0.288854E+10 | 0.00 | 2491905.46 | 47144749.35 | 0.00 | 0.157595E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.378071E+09 | 162077.35 | 0.00 | 5071758.37 | 318098.71 | 0.00 | 0.280727E+09 | 0.00 | 0.36 |
| February | 0.138942E+09 | 10202871.16 | 0.00 | 7245137.31 | 4122878.16 | 0.00 | 0.236429E+09 | 0.00 | 0.36 |
| March | 51105739.45 | 0.188348E+09 | 0.00 | 3747645.86 | 9945511.93 | 0.00 | 78049901.13 | 0.00 | 0.36 |
| April | 7148258.43 | 0.600717E+09 | 0.00 | 533857.38 | 6947727.62 | 0.00 | 7032653.97 | 0.00 | 0.36 |
| May | 0.00 | 0.147535E+10 | 0.00 | 0.00 | 1322118.53 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.213057E+10 | 0.00 | 0.00 | 4035380.64 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.287549E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.290240E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.225619E+10 | 0.00 | 0.00 | 3434848.56 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 15602669.96 | 0.627559E+09 | 0.00 | 399131.50 | 46203293.33 | 0.00 | 5397324.43 | 0.00 | 0.36 |
| November | 66555029.84 | 79290084.78 | 0.00 | 5874176.43 | 12590627.41 | 0.00 | 0.162986E+09 | 0.00 | 0.36 |
| December | 0.181501E+09 | 1422314.18 | 0.00 | 6980621.58 | 1134356.20 | 0.00 | 0.406098E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.838926E+09 | 0.131477E+11 | 0.00 | 29852328.44 | 90054841.10 | 0.00 | 0.117672E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 162077.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.378071E+09 | 0.290240E+10 | 0.00 | 7245137.31 | 46203293.33 | 0.00 | 0.406098E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.544385E+09 | 0.00 | 0.00 | 326643.14 | 1023052.34 | 0.00 | 56980068.42 | 0.00 | 0.35 |
| February | 0.232179E+09 | 7270127.25 | 0.00 | 2154256.93 | 2797731.00 | 0.00 | 0.148517E+09 | 0.00 | 0.36 |
| March | 57512758.30 | 0.170865E+09 | 0.00 | 2628087.95 | 10028436.70 | 0.00 | 82565694.98 | 0.00 | 0.36 |
| April | 7288705.24 | 0.590152E+09 | 0.00 | 446799.39 | 7015870.59 | 0.00 | 6978725.79 | 0.00 | 0.36 |
| May | 0.00 | 0.147251E+10 | 0.00 | 0.00 | 1351532.37 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.213091E+10 | 0.00 | 0.00 | 4033272.16 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.287581E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.289004E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.221690E+10 | 0.00 | 0.00 | 3276355.25 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 17753813.00 | 0.576042E+09 | 0.00 | 298549.07 | 45736664.87 | 0.00 | 7989974.36 | 0.00 | 0.36 |
| November | 96826032.57 | 59925587.39 | 0.00 | 2314781.92 | 12114450.13 | 0.00 | 0.160411E+09 | 0.00 | 0.36 |
| December | 0.463264E+09 | 698403.09 | 0.00 | 799927.79 | 1838244.00 | 0.00 | 0.121676E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.141921E+10 | 0.129911E+11 | 0.00 | 8969046.20 | 89215609.40 | 0.00 | 0.585119E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.544385E+09 | 0.289004E+10 | 0.00 | 2628087.95 | 45736664.87 | 0.00 | 0.160411E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.451143E+09 | 0.00 | 0.00 | 1085860.50 | 720742.41 | 0.00 | 0.174145E+09 | 0.00 | 0.35 |
| February | 0.145536E+09 | 6976791.13 | 0.00 | 2856900.18 | 3002919.22 | 0.00 | 0.225046E+09 | 0.00 | 0.36 |
| March | 56327867.23 | 0.161909E+09 | 0.00 | 2620863.17 | 10177926.03 | 0.00 | 79658231.83 | 0.00 | 0.36 |
| April | 7611575.04 | 0.562762E+09 | 0.00 | 397752.58 | 6968374.48 | 0.00 | 6739688.96 | 0.00 | 0.36 |
| May | 0.00 | 0.141957E+10 | 0.00 | 0.00 | 1353109.85 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.206018E+10 | 0.00 | 0.00 | 4020305.06 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.278789E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.279813E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.214355E+10 | 0.00 | 0.00 | 3165178.62 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 17385315.10 | 0.549019E+09 | 0.00 | 349631.24 | 45412110.73 | 0.00 | 7201863.49 | 0.00 | 0.36 |
| November | 73833302.37 | 56937962.88 | 0.00 | 2929545.56 | 11738404.30 | 0.00 | 0.168500E+09 | 0.00 | 0.36 |
| December | 0.205637E+09 | 743053.99 | 0.00 | 2221474.80 | 1691032.72 | 0.00 | 0.382271E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.957474E+09 | 0.125477E+11 | 0.00 | 12462028.05 | 88250103.43 | 0.00 | 0.104356E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.451143E+09 | 0.279813E+10 | 0.00 | 2929545.56 | 45412110.73 | 0.00 | 0.382271E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.450809E+09 | 0.00 | 0.00 | 1090902.36 | 712788.25 | 0.00 | 0.174776E+09 | 0.00 | 0.35 |
| February | 0.144532E+09 | 6990697.51 | 0.00 | 2876870.67 | 3012629.67 | 0.00 | 0.226121E+09 | 0.00 | 0.36 |
| March | 56329302.54 | 0.162077E+09 | 0.00 | 2630671.86 | 10161452.86 | 0.00 | 79696015.56 | 0.00 | 0.36 |
| April | 7612290.32 | 0.562924E+09 | 0.00 | 398620.33 | 6967611.23 | 0.00 | 6741229.97 | 0.00 | 0.36 |
| May | 0.00 | 0.141966E+10 | 0.00 | 0.00 | 1352788.62 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.206004E+10 | 0.00 | 0.00 | 4018842.96 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.278796E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.279823E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.214351E+10 | 0.00 | 0.00 | 3163509.41 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 17391447.37 | 0.549288E+09 | 0.00 | 349964.11 | 45403823.93 | 0.00 | 7196699.02 | 0.00 | 0.36 |
| November | 73868256.57 | 57035192.16 | 0.00 | 2932121.05 | 11747827.74 | 0.00 | 0.168490E+09 | 0.00 | 0.36 |
| December | 0.205240E+09 | 749259.51 | 0.00 | 2225338.41 | 1672047.90 | 0.00 | 0.382830E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.955783E+09 | 0.125485E+11 | 0.00 | 12504488.79 | 88213322.55 | 0.00 | 0.104585E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.450809E+09 | 0.279823E+10 | 0.00 | 2932121.05 | 45403823.93 | 0.00 | 0.382830E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.149339E+09 | 139374.16 | 0.00 | 7554628.17 | 329369.77 | 0.00 | 0.502999E+09 | 0.00 | 0.36 |
| February | 94319209.18 | 10233424.92 | 0.00 | 8145963.93 | 4205200.55 | 0.00 | 0.266550E+09 | 0.00 | 0.36 |
| March | 48723582.58 | 0.182787E+09 | 0.00 | 3735081.21 | 9916164.22 | 0.00 | 77423526.39 | 0.00 | 0.36 |
| April | 7501016.40 | 0.577755E+09 | 0.00 | 488558.08 | 7092348.52 | 0.00 | 6784558.96 | 0.00 | 0.36 |
| May | 0.00 | 0.142475E+10 | 0.00 | 0.00 | 1324316.01 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.206026E+10 | 0.00 | 0.00 | 3984599.28 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.278841E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.281530E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.219637E+10 | 0.00 | 0.00 | 3356105.44 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 15079881.02 | 0.612176E+09 | 0.00 | 392907.72 | 46278593.31 | 0.00 | 4680007.49 | 0.00 | 0.36 |
| November | 61696670.55 | 78114021.10 | 0.00 | 6476309.30 | 12584936.80 | 0.00 | 0.153918E+09 | 0.00 | 0.36 |
| December | 94241497.26 | 1487336.41 | 0.00 | 9047510.22 | 1314553.86 | 0.00 | 0.479627E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.470901E+09 | 0.127478E+11 | 0.00 | 35840958.64 | 90386187.75 | 0.00 | 0.149198E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 139374.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.149339E+09 | 0.281530E+10 | 0.00 | 9047510.22 | 46278593.31 | 0.00 | 0.502999E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: M S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.149546E+09 | 139397.17 | 0.00 | 7564448.42 | 329586.08 | 0.00 | 0.502940E+09 | 0.00 | 0.36 |
| February | 94533562.43 | 10249663.89 | 0.00 | 8174678.75 | 4220220.17 | 0.00 | 0.266450E+09 | 0.00 | 0.36 |
| March | 48735794.22 | 0.182892E+09 | 0.00 | 3740986.55 | 9918860.27 | 0.00 | 77399883.26 | 0.00 | 0.36 |
| April | 7482798.69 | 0.577876E+09 | 0.00 | 489867.13 | 7092030.19 | 0.00 | 6832669.04 | 0.00 | 0.36 |
| May | 0.00 | 0.142486E+10 | 0.00 | 0.00 | 1324020.88 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.206014E+10 | 0.00 | 0.00 | 3983220.45 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.278849E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.281540E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.219634E+10 | 0.00 | 0.00 | 3354812.35 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 15069646.49 | 0.612309E+09 | 0.00 | 393222.48 | 46293701.24 | 0.00 | 4694378.69 | 0.00 | 0.36 |
| November | 61749857.18 | 78185942.12 | 0.00 | 6484957.87 | 12578125.70 | 0.00 | 0.153885E+09 | 0.00 | 0.36 |
| December | 94124573.62 | 1495082.48 | 0.00 | 9058339.96 | 1305178.39 | 0.00 | 0.479853E+09 | 0.00 | 0.35 |
| Annual Sum or Average | 0.471242E+09 | 0.127484E+11 | 0.00 | 35906501.16 | 90399755.73 | 0.00 | 0.149206E+10 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 139397.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.149546E+09 | 0.281540E+10 | 0.00 | 9058339.96 | 46293701.24 | 0.00 | 0.502940E+09 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T SW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.186789E+09 | 112984.92 | 0.00 | 1473214.74 | 185562.62 | 80205575.74 | 22951406.55 | 0.00 | 0.35 |
| February | 0.143965E+09 | 5165515.05 | 0.00 | 2251922.72 | 1912848.45 | 10311217.78 | 25789284.26 | 0.00 | 0.36 |
| March | 50285708.33 | 90809488.20 | 0.00 | 1333913.68 | 4835568.88 | 0.00 | 23410565.50 | 0.00 | 0.36 |
| April | 4089513.30 | 0.292944E+09 | 0.00 | 184331.03 | 3129511.18 | 0.00 | 3787773.94 | 0.00 | 0.36 |
| May | 2016.83 | 0.735823E+09 | 0.00 | 1246.71 | 508364.46 | 0.00 | 4241.07 | 0.00 | 0.36 |
| June | 0.00 | 0.107197E+10 | 0.00 | 0.00 | 1845339.95 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.144790E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.145797E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.111859E+10 | 0.00 | 0.00 | 1516617.14 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 13781547.48 | 0.297957E+09 | 0.00 | 128906.90 | 20337431.12 | 0.00 | 4463784.65 | 0.00 | 0.36 |
| November | 0.111231E+09 | 38506663.19 | 0.00 | 1821723.97 | 6242188.88 | 0.00 | 25506458.71 | 0.00 | 0.36 |
| December | 0.209056E+09 | 898283.96 | 0.00 | 1866219.10 | 644713.74 | 24239370.05 | 33857660.22 | 0.00 | 0.35 |
| Annual Sum or Average | 0.719201E+09 | 0.655865E+10 | 0.00 | 9061478.85 | 41158146.43 | 0.114756E+09 | 0.139771E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 112984.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.209056E+09 | 0.145797E+10 | 0.00 | 2251922.72 | 20337431.12 | 80205575.74 | 33857660.22 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T NW APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.123088E+09 | 0.00 | 0.00 | 8603.83 | 449759.24 | 0.131978E+09 | 645918.75 | 0.00 | 0.35 |
| February | 0.133811E+09 | 3787235.06 | 0.00 | 455467.84 | 1423397.29 | 25648972.12 | 11211088.64 | 0.00 | 0.36 |
| March | 55972864.18 | 83036271.33 | 0.00 | 870559.61 | 5142212.27 | 0.00 | 20967659.77 | 0.00 | 0.36 |
| April | 4191965.12 | 0.288642E+09 | 0.00 | 152240.47 | 3155759.80 | 0.00 | 3705378.63 | 0.00 | 0.36 |
| May | 0.00 | 0.735003E+09 | 0.00 | 623.23 | 518674.99 | 0.00 | 1139.64 | 0.00 | 0.36 |
| June | 0.00 | 0.107191E+10 | 0.00 | 0.00 | 1848382.30 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.144799E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.145283E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.110201E+10 | 0.00 | 0.00 | 1463620.07 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 16652221.20 | 0.273377E+09 | 0.00 | 76558.38 | 21170183.86 | 0.00 | 4311643.34 | 0.00 | 0.36 |
| November | 0.124838E+09 | 28678199.80 | 0.00 | 413545.21 | 6306562.78 | 0.00 | 12531255.47 | 0.00 | 0.36 |
| December | 0.159150E+09 | 399485.78 | 0.00 | 43977.46 | 1613431.24 | 77217731.69 | 1749996.24 | 0.00 | 0.35 |
| Annual Sum or Average | 0.617704E+09 | 0.648766E+10 | 0.00 | 2021576.02 | 43091983.84 | 0.234845E+09 | 55124080.48 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.159150E+09 | 0.145283E+10 | 0.00 | 870559.61 | 21170183.86 | 0.131978E+09 | 20967659.77 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T SE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.195212E+09 | 105394.52 | 0.00 | 1397906.71 | 205266.35 | 74811758.26 | 22175232.51 | 0.00 | 0.35 |
| February | 0.147175E+09 | 5037604.08 | 0.00 | 2532611.27 | 1893381.66 | 9499532.64 | 27658138.61 | 0.00 | 0.36 |
| March | 52496151.39 | 91202511.61 | 0.00 | 1501705.45 | 4660940.86 | 0.00 | 23723967.71 | 0.00 | 0.36 |
| April | 4169248.07 | 0.294998E+09 | 0.00 | 239031.19 | 2725945.76 | 0.00 | 4026453.34 | 0.00 | 0.36 |
| May | 0.00 | 0.736942E+09 | 0.00 | 1371.33 | 497151.36 | 0.00 | 7832.40 | 0.00 | 0.36 |
| June | 0.00 | 0.107070E+10 | 0.00 | 0.00 | 1831285.41 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.144771E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.145805E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.111823E+10 | 0.00 | 0.00 | 1487517.26 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 14242297.92 | 0.298867E+09 | 0.00 | 162655.53 | 20269936.50 | 0.00 | 4929532.76 | 0.00 | 0.36 |
| November | 0.113833E+09 | 38811094.63 | 0.00 | 2003397.00 | 6295640.01 | 0.00 | 25842163.03 | 0.00 | 0.36 |
| December | 0.213335E+09 | 821959.30 | 0.00 | 1858641.28 | 627126.01 | 23557494.25 | 33223319.77 | 0.00 | 0.35 |
| Annual Sum or Average | 0.740462E+09 | 0.656147E+10 | 0.00 | 9697319.77 | 40494191.19 | 0.107869E+09 | 0.141587E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 105394.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.213335E+09 | 0.145805E+10 | 0.00 | 2532611.27 | 20269936.50 | 74811758.26 | 33223319.77 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T NE APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.126550E+09 | 0.00 | 0.00 | 5424.72 | 598154.71 | 0.126893E+09 | 541939.06 | 0.00 | 0.35 |
| February | 0.138849E+09 | 3772719.01 | 0.00 | 469897.80 | 1459713.47 | 23574740.72 | 10957931.31 | 0.00 | 0.36 |
| March | 59118050.48 | 83862145.61 | 0.00 | 951873.87 | 4735266.00 | 0.00 | 20779326.91 | 0.00 | 0.36 |
| April | 4289578.38 | 0.291019E+09 | 0.00 | 198867.36 | 2714335.60 | 0.00 | 3976598.54 | 0.00 | 0.36 |
| May | 0.00 | 0.736074E+09 | 0.00 | 721.55 | 507233.21 | 0.00 | 1816.99 | 0.00 | 0.36 |
| June | 0.00 | 0.107063E+10 | 0.00 | 0.00 | 1834237.43 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.144779E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.145297E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.110205E+10 | 0.00 | 0.00 | 1424101.61 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 17813979.36 | 0.276170E+09 | 0.00 | 104930.79 | 20019614.22 | 0.00 | 4530177.97 | 0.00 | 0.36 |
| November | 0.129347E+09 | 29499134.36 | 0.00 | 441523.22 | 5963767.14 | 0.00 | 10976359.81 | 0.00 | 0.36 |
| December | 0.163392E+09 | 395915.60 | 0.00 | 28560.14 | 1490799.61 | 73253488.12 | 951852.65 | 0.00 | 0.35 |
| Annual Sum or Average | 0.639360E+09 | 0.649424E+10 | 0.00 | 2201799.46 | 40747223.00 | 0.223722E+09 | 52716003.24 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.163392E+09 | 0.145297E+10 | 0.00 | 951873.87 | 20019614.22 | 0.126893E+09 | 20779326.91 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T N1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.163872E+09 | 0.00 | 0.00 | 19217.27 | 722834.24 | 95515724.25 | 2955629.15 | 0.00 | 0.35 |
| February | 0.151055E+09 | 3506231.45 | 0.00 | 493161.93 | 1577115.15 | 7379674.96 | 19524255.96 | 0.00 | 0.36 |
| March | 46950458.07 | 79995814.24 | 0.00 | 918447.55 | 4815672.98 | 0.00 | 31114400.97 | 0.00 | 0.36 |
| April | 4231566.51 | 0.280185E+09 | 0.00 | 175020.49 | 3190069.15 | 0.00 | 3756230.86 | 0.00 | 0.36 |
| May | 0.00 | 0.718192E+09 | 0.00 | 305.54 | 541320.26 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.104691E+10 | 0.00 | 0.00 | 1875186.25 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.141917E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.142171E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.107636E+10 | 0.00 | 0.00 | 1456385.88 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 13164770.44 | 0.266159E+09 | 0.00 | 109347.18 | 20779390.42 | 0.00 | 6697729.85 | 0.00 | 0.36 |
| November | 0.117266E+09 | 27070919.02 | 0.00 | 524650.18 | 5777508.75 | 0.00 | 25488816.58 | 0.00 | 0.36 |
| December | 0.215257E+09 | 276772.18 | 0.00 | 51900.19 | 1824843.04 | 29841307.73 | 4596847.71 | 0.00 | 0.35 |
| Annual Sum or Average | 0.711797E+09 | 0.633954E+10 | 0.00 | 2292050.33 | 42560326.11 | 0.132737E+09 | 94133911.08 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.215257E+09 | 0.142171E+10 | 0.00 | 918447.55 | 20779390.42 | 95515724.25 | 31114400.97 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T N2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.163838E+09 | 0.00 | 0.00 | 18649.39 | 715327.87 | 95809716.41 | 2649943.81 | 0.00 | 0.35 |
| February | 0.151155E+09 | 3514863.19 | 0.00 | 499162.35 | 1575544.39 | 7369840.31 | 19590453.99 | 0.00 | 0.36 |
| March | 46939749.41 | 80183720.45 | 0.00 | 925169.88 | 4730565.37 | 0.00 | 31231228.44 | 0.00 | 0.36 |
| April | 4234690.07 | 0.280303E+09 | 0.00 | 176177.78 | 3186839.62 | 0.00 | 3760236.06 | 0.00 | 0.36 |
| May | 0.00 | 0.718277E+09 | 0.00 | 310.49 | 540797.86 | 0.00 | 0.00 | 0.00 | 0.36 |
| June | 0.00 | 0.104685E+10 | 0.00 | 0.00 | 1911047.38 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.141924E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.142180E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.107638E+10 | 0.00 | 0.00 | 1454581.08 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 13251728.44 | 0.266386E+09 | 0.00 | 110468.16 | 20742787.64 | 0.00 | 6668094.84 | 0.00 | 0.36 |
| November | 0.117487E+09 | 27174157.96 | 0.00 | 525729.28 | 5797756.10 | 0.00 | 25324234.78 | 0.00 | 0.36 |
| December | 0.215431E+09 | 274666.31 | 0.00 | 50962.59 | 1797053.32 | 29759512.21 | 4464429.63 | 0.00 | 0.35 |
| Annual Sum or Average | 0.712338E+09 | 0.634037E+10 | 0.00 | 2306629.92 | 42452300.64 | 0.132939E+09 | 93688621.54 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.215431E+09 | 0.142180E+10 | 0.00 | 925169.88 | 20742787.64 | 95809716.41 | 31231228.44 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T S1 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.248257E+09 | 103117.68 | 0.00 | 1698202.21 | 197690.09 | 12834101.54 | 44468833.40 | 0.00 | 0.35 |
| February | 0.139834E+09 | 4933629.22 | 0.00 | 2662548.46 | 1929384.75 | 2228992.39 | 47182413.87 | 0.00 | 0.36 |
| March | 35943525.04 | 88948500.77 | 0.00 | 1467295.54 | 4703409.17 | 0.00 | 37935458.05 | 0.00 | 0.36 |
| April | 4129954.74 | 0.285283E+09 | 0.00 | 209254.32 | 3147574.21 | 0.00 | 3828584.29 | 0.00 | 0.36 |
| May | 0.00 | 0.718892E+09 | 0.00 | 1044.93 | 528163.44 | 0.00 | 3930.81 | 0.00 | 0.36 |
| June | 0.00 | 0.104625E+10 | 0.00 | 0.00 | 1870041.74 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.141856E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.142783E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.109718E+10 | 0.00 | 0.00 | 1516475.87 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 10448589.12 | 0.293915E+09 | 0.00 | 159227.29 | 20806841.54 | 0.00 | 6078614.09 | 0.00 | 0.36 |
| November | 87887896.93 | 37902334.23 | 0.00 | 2184707.03 | 6224168.87 | 0.00 | 50009376.55 | 0.00 | 0.36 |
| December | 0.222292E+09 | 792383.31 | 0.00 | 2261017.51 | 597502.05 | 2849828.60 | 58775294.67 | 0.00 | 0.35 |
| Annual Sum or Average | 0.748792E+09 | 0.642060E+10 | 0.00 | 10643297.29 | 41521251.75 | 17912922.53 | 0.248283E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 103117.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.248257E+09 | 0.142783E+10 | 0.00 | 2662548.46 | 20806841.54 | 12834101.54 | 58775294.67 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: T S2 APARTMENT
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
| January | 0.248059E+09 | 103147.60 | 0.00 | 1711888.73 | 198064.56 | 12950566.20 | 44835333.97 | 0.00 | 0.35 |
| February | 0.140005E+09 | 4937837.57 | 0.00 | 2691796.08 | 1925357.28 | 2228612.27 | 47269083.30 | 0.00 | 0.36 |
| March | 35963937.57 | 88992817.63 | 0.00 | 1476368.68 | 4731003.17 | 0.00 | 37987319.65 | 0.00 | 0.36 |
| April | 4096909.28 | 0.285392E+09 | 0.00 | 210549.17 | 3139863.29 | 0.00 | 3865744.49 | 0.00 | 0.36 |
| May | 0.00 | 0.718988E+09 | 0.00 | 1047.21 | 527664.62 | 0.00 | 3969.20 | 0.00 | 0.36 |
| June | 0.00 | 0.104624E+10 | 0.00 | 0.00 | 1869314.06 | 0.00 | 0.00 | 0.00 | 0.36 |
| July | 0.00 | 0.141864E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| August | 0.00 | 0.142792E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
| September | 0.00 | 0.109719E+10 | 0.00 | 0.00 | 1514999.65 | 0.00 | 0.00 | 0.00 | 0.36 |
| October | 10474851.37 | 0.294052E+09 | 0.00 | 159570.23 | 20770236.08 | 0.00 | 6087797.94 | 0.00 | 0.36 |
| November | 88405630.60 | 37951033.22 | 0.00 | 2194157.16 | 6225831.65 | 0.00 | 49626290.55 | 0.00 | 0.36 |
| December | 0.222393E+09 | 790062.42 | 0.00 | 2273530.35 | 592059.85 | 2850487.64 | 58795651.68 | 0.00 | 0.35 |
| Annual Sum or Average | 0.749398E+09 | 0.642120E+10 | 0.00 | 10718907.61 | 41494394.22 | 18029666.11 | 0.248471E+09 | 0.00 | 0.36 |
| Minimum of Months | 0.00 | 103147.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
| Maximum of Months | 0.248059E+09 | 0.142792E+10 | 0.00 | 2691796.08 | 20770236.08 | 12950566.20 | 58795651.68 | 0.00 | 0.36 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2024-07-03 12:21:22
Custom Monthly Report| SITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
| January | 0.899883E+11 | 0.701934E+10 | 0.00 | 0.132117E+10 | 0.127580E+11 |
| February | 0.955268E+11 | 0.606667E+10 | 0.00 | 0.885099E+09 | 0.315234E+11 |
| March | 0.118857E+12 | 0.340079E+10 | 0.00 | 0.415529E+09 | 0.873597E+11 |
| April | 0.119337E+12 | -625669915.2 | 0.00 | -279585278.3 | 0.150703E+12 |
| May | 0.118736E+12 | -0.310193E+10 | 0.00 | -0.106143E+10 | 0.206225E+12 |
| June | 0.111190E+12 | -0.311582E+10 | 0.00 | -0.150104E+10 | 0.218826E+12 |
| July | 0.981625E+11 | -0.487371E+10 | 0.00 | -0.186574E+10 | 0.233494E+12 |
| August | 0.860132E+11 | -0.355180E+10 | 0.00 | -0.178080E+10 | 0.220719E+12 |
| September | 0.961066E+11 | -0.197649E+10 | 0.00 | -0.113620E+10 | 0.188804E+12 |
| October | 0.984602E+11 | 0.933920E+09 | 0.00 | 14107561.86 | 0.133987E+12 |
| November | 0.933040E+11 | 0.401400E+10 | 0.00 | 0.771553E+09 | 0.686740E+11 |
| December | 0.824751E+11 | 0.660550E+10 | 0.00 | 0.128372E+10 | 0.231388E+11 |
| Annual Sum or Average | 0.120816E+13 | 0.107948E+11 | 0.00 | -0.293360E+10 | 0.157621E+13 |
| Minimum of Months | 0.824751E+11 | -0.487371E+10 | 0.00 | -0.186574E+10 | 0.127580E+11 |
| Maximum of Months | 0.119337E+12 | 0.701934E+10 | 0.00 | 0.132117E+10 | 0.233494E+12 |